  • APC Smart UPS network shutdown issue

    - by Rob Clarke
    Here is a bit about our setup: We have 2x Smart-UPS RT 6000 XL units with network management cards We are running Powerchute from a network server Powerchute is connected to the management cards of both UPSs UPSs are set to do a graceful shutdown via Powerchute when the battery duration is under 20 minutes We also have a command file that runs with Powerchute Although our setup is redundant we do not have an equal load on each server due to APC switches for single power devices The problem is that as we do not have an equal load on each server the batteries drain at different rates. This means that the UPSs both get to the specified low battery duration at completely different times. The problem here is that UPS 1 may have run down to 5 minutes and is in desperate need of initiating a Powerchute shutdown - UPS 2 still has 25 minutes of runtime so no shutdown is initiated. Consequently UPS 1 goes down and takes all the servers with and then shuts down UPS 2 as well! What we need to happen are 1 of either 2 things: Powerchute initiates the shutdown as soon as either UPS reaches the 20 minutes low battery duration setting - and doesnt wait for both The UPS with the heavier load expends its entire battery but does not shutdown both UPSs and lets the load be switched across to the UPS that still has runtime remaining. That way when the UPS that still has runtime reaches its low battery duration it can proceed with the graceful shutdown via Powerchute. Hope that makes sense, any help is greatly appreciated!

    Read the article

  • Can't create add a SQL Server user: The login already has an account under a different user name.

    - by Zian Choy
    Environment: SQL Server 2005 Express Windows 7 When I installed SQL Server, I followed the instructions at http://msdn.microsoft.com/en-us/library/aa905868.aspx to set my computer's admin account as the SQL Server admin. However, when I try to access a database on my computer through Visual Studio 2008, I get the following error message: --------------------------- Microsoft Visual Studio --------------------------- The database 'Parkinsons' does not exist or you do not have permission to see it. Would you like to attempt to create it? --------------------------- Yes No --------------------------- Then, if I go to SQL Server and add a user to that database, I get the following error message: TITLE: Microsoft SQL Server Management Studio Express ------------------------------ Create failed for User 'zian'. (Microsoft.SqlServer.Express.Smo) For help, click: http://go.microsoft.com/fwlink?ProdName=Microsoft+SQL+Server&ProdVer=9.00.2047.00&EvtSrc=Microsoft.SqlServer.Management.Smo.ExceptionTemplates.FailedOperationExceptionText&EvtID=Create+User&LinkId=20476 ------------------------------ ADDITIONAL INFORMATION: An exception occurred while executing a Transact-SQL statement or batch. (Microsoft.SqlServer.Express.ConnectionInfo) ------------------------------ The login already has an account under a different user name. (Microsoft SQL Server, Error: 15063) For help, click: http://go.microsoft.com/fwlink?ProdName=Microsoft+SQL+Server&ProdVer=09.00.4053&EvtSrc=MSSQLServer&EvtID=15063&LinkId=20476 ------------------------------ BUTTONS: OK ------------------------------ Why doesn't VS piggy back on the dbo account? If the dbo account is unusable, then why won't SQL Server let me make an account so that I can access my own data?

    Read the article

  • FreeBSD ZFS RAID-Z2 performance issues

    - by Axel Gneiting
    I'm trying to build my own network attached storage based on FreeBSD+ZFS+standard components, but there are strange performance issues. The hardware specs are: AMD Athlon II X2 240e processor ASUS M4A78LT-M LE mainboard 2GiB Kingston ECC DDR3 (two sticks) Intel Pro/1000 CT PCIe network adapter 5x Western Digital Caviar Green 1.5TB I created a RAID-Z2 zpool from all disks. I installed FreeBSD 8.1 on that zpool following the tutorial. The SATA controllers are running in AHCI mode. Output of zpool status: pool: zroot state: ONLINE scrub: none requested config: NAME STATE READ WRITE CKSUM zroot ONLINE 0 0 0 raidz2 ONLINE 0 0 0 gptid/7ef815fc-eab6-11df-8ea4-001b2163266d ONLINE 0 0 0 gptid/80344432-eab6-11df-8ea4-001b2163266d ONLINE 0 0 0 gptid/81741ad9-eab6-11df-8ea4-001b2163266d ONLINE 0 0 0 gptid/824af5cb-eab6-11df-8ea4-001b2163266d ONLINE 0 0 0 gptid/82f98a65-eab6-11df-8ea4-001b2163266d ONLINE 0 0 0 The problem is that write performance on the pool is very very bad (<10 MB/s) and every application that is accessing the disk is unresponsive every few seconds when writing. It seems like writing is fine until the ZFS ark cache is full and then ZFS stalls the entire system I/O till it's finished writing that data. Also I'm getting kmem_malloc to small kernel panics. I've already tried to put vm.kmem_size="1500M" vm.kmem_size_max="1500M" into /boot/loader.conf, but it doesn't help. Does anyone know what's going on here? Am I really not having enough memory for ZFS to handle this RAID-Z2?

    Read the article

  • Natting trafic from a tunnel to internet

    - by mezgani
    I'm trying to set up a GRE tunnel between a linux box and a router (LAN), and I'm having a few problems which seem to depend to my iptables configuration. Watching with tcpdump on linux box, I can see packets coming with flags GREv0, all i need right know is forwarding this data to internet, found here some trace : iptables -F iptables -X iptables -P INPUT ACCEPT iptables -P FORWARD ACCEPT iptables -P OUTPUT ACCEPT iptables -t nat -F iptables -t nat -X iptables -t nat -P PREROUTING ACCEPT iptables -t nat -P POSTROUTING ACCEPT iptables -t nat -P OUTPUT ACCEPT iptables -t mangle -F iptables -t mangle -X iptables -t mangle -P PREROUTING ACCEPT iptables -t mangle -P OUTPUT ACCEPT iptables -A INPUT -p 47 -j ACCEPT iptables -A FORWARD -i ppp0 -o cloud -j ACCEPT iptables -A FORWARD -i cloud -o ppp0 -j ACCEPT iptables -A FORWARD -m state --state ESTABLISHED,RELATED -j ACCEPT iptables -t nat -A POSTROUTING -o ppp0 -j MASQUERADE echo "1" /proc/sys/net/ipv4/ip_forward cloud Link encap:UNSPEC HWaddr C4-CE-7A-2E-F2-BF-DD-C0-00-00-00-00-00-00-00-00 inet adr:10.3.3.3 P-t-P:10.3.3.3 Masque:255.255.255.255 UP POINTOPOINT RUNNING NOARP MTU:1476 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:124 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 lg file transmission:0 RX bytes:0 (0.0 B) TX bytes:10416 (10.1 KiB) Table de routage IP du noyau Destination Passerelle Genmask Indic MSS Fenêtre irtt Iface 196.206.120.1 0.0.0.0 255.255.255.255 UH 0 0 0 ppp0 192.168.0.0 0.0.0.0 255.255.255.0 U 0 0 0 eth0 10.3.3.0 0.0.0.0 255.255.255.0 U 0 0 0 cloud 0.0.0.0 196.206.120.1 0.0.0.0 UG 0 0 0 ppp0 root@aldebaran:~# ip route 196.206.120.1 dev ppp0 proto kernel scope link src 196.206.122.46 192.168.0.0/24 dev eth0 proto kernel scope link src 192.168.0.18 10.3.3.0/24 dev cloud scope link default via 196.206.120.1 dev ppp0

    Read the article

  • Degraded RAID-5 array with lvm2 lost superblock and partition table

    - by Fred Phillips
    I have a RAID-5 array of 4x1TB hard disks with one lvm2 partition on Ubuntu Linux 10.04 LTS. One of the disks has failed. I have re-assembled the array without this failed disk but now mdadm --examine claims the array has no superblock and fdisk says it has no partition table. What can I do to recover the data? # mdadm -D /dev/md0 /dev/md0: Version : 1.2 Creation Time : Sat Mar 5 14:43:49 2011 Raid Level : raid5 Array Size : 2930276352 (2794.53 GiB 3000.60 GB) Used Dev Size : 976758784 (931.51 GiB 1000.20 GB) Raid Devices : 4 Total Devices : 4 Persistence : Superblock is persistent Update Time : Sat Mar 5 15:06:49 2011 State : clean, degraded Active Devices : 3 Working Devices : 3 Failed Devices : 1 Spare Devices : 0 Layout : left-symmetric Chunk Size : 512K Name : boba:1 (local to host boba) UUID : 52eb4bc9:c3d8aab5:e0699505:e0e1aa05 Events : 18 Number Major Minor RaidDevice State 0 8 1 0 active sync /dev/sda1 1 8 65 1 active sync /dev/sde1 2 8 49 2 active sync /dev/sdd1 3 0 0 3 removed 4 8 17 - faulty spare /dev/sdb1 # mdadm --examine /dev/md0 mdadm: No md superblock detected on /dev/md0. # fdisk -l /dev/md0 Disk /dev/md0: 3000.6 GB, 3000602984448 bytes 2 heads, 4 sectors/track, 732569088 cylinders Units = cylinders of 8 * 512 = 4096 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 524288 bytes / 1572864 bytes Disk identifier: 0x00000000 Disk /dev/md0 doesn't contain a valid partition table # cat /proc/mdstat Personalities : [raid6] [raid5] [raid4] [linear] [multipath] [raid0] [raid1] [raid10] md0 : active raid5 sdb1[4](F) sda1[0] sdd1[2] sde1[1] 2930276352 blocks super 1.2 level 5, 512k chunk, algorithm 2 [4/3] [UUU_] unused devices: <none>

    Read the article

  • Fedora 12 on Vmware network disabled on restore

    - by Chaitanya
    I have a fedora 12 guest running on VMWare on windows 7. I use it mainly for the occasional linux dev. Whenever I restart the guest, networking works fine. But if I close the VMware player and save state, the next time I start the image, networking is disabled (red x on the network icon. message saying networking disabled). I can't seem to find a way to restore networking. I have to reboot the guest to get my network access back again. My Ubuntu image doesn't have this problem. I can close the player and when I re run the image, I can pick up where I left off, with all the open firefox windows and application windows as I left them. Fedora saves state, but doesn't seem to enable networking. There is a relevant warning I have seen "SELinux is preventing /sbin/ifconfig "read" access to/var/run/vmware-active-nics." But I am not sure how to solve it. I know fedora isn't officially supported by VMware, but it seems to be working fine for the most part and meeting my needs, except for this one little issue. Any help would be much appreciated.

    Read the article

  • Prevent master to fall back to master after failure

    - by Chrille
    I'm using keepalived to setup a virtual ip that points to a master server. When a failover happens it should point the virtual ip to the backup, and the IP should stay there until I manually enable (fix) the master. The reason this is important is that I'm running mysql replication on the servers and writes should only be on the master. When I failover I promote the slave to master. The master server: global_defs { ! this is who emails will go to on alerts notification_email { [email protected] ! add a few more email addresses here if you would like } notification_email_from [email protected] ! I use the local machine to relay mail smtp_server 127.0.0.1 smtp_connect_timeout 30 ! each load balancer should have a different ID ! this will be used in SMTP alerts, so you should make ! each router easily identifiable lvs_id APP1 } vrrp_instance APP1 { interface eth0 state EQUAL virtual_router_id 61 priority 999 nopreempt virtual_ipaddress { 217.x.x.129 } smtp_alert } Backup server: global_defs { ! this is who emails will go to on alerts notification_email { [email protected] ! add a few more email addresses here if you would like } notification_email_from [email protected] ! I use the local machine to relay mail smtp_server 127.0.0.1 smtp_connect_timeout 30 ! each load balancer should have a different ID ! this will be used in SMTP alerts, so you should make ! each router easily identifiable lvs_id APP2 } vrrp_instance APP2 { interface eth0 state EQUAL virtual_router_id 61 priority 100 virtual_ipaddress { 217.xx.xx.129 } notify_master "/etc/keepalived/notify.sh del app2" notify_backup "/etc/keepalived/notify.sh add app2" notify_fault "/etc/keepalived/notify.sh add app2” smtp_alert }

    Read the article

  • How to get automatic upgrades to work on Ubuntu Server?

    - by J. Pablo Fernández
    I followed the documentation for enabling automatic upgrades in Ubuntu servers, but it's not really updating anything at all. My /etc/apt/apt.conf.d/50unattended-upgrades looks almost like the default. // Automatically upgrade packages from these (origin, archive) pairs Unattended-Upgrade::Allowed-Origins { "Ubuntu karmic-security"; "Ubuntu karmic-updates"; }; // List of packages to not update Unattended-Upgrade::Package-Blacklist { // "vim"; // "libc6"; // "libc6-dev"; // "libc6-i686"; }; // Send email to this address for problems or packages upgrades // If empty or unset then no email is sent, make sure that you // have a working mail setup on your system. The package 'mailx' // must be installed or anything that provides /usr/bin/mail. Unattended-Upgrade::Mail "[email protected]"; // Automatically reboot *WITHOUT CONFIRMATION* if a // the file /var/run/reboot-required is found after the upgrade //Unattended-Upgrade::Automatic-Reboot "false"; The directory /var/log/unattended-upgrades/ is empty. Running /etc/init.d/unattended-upgrades start is not very nice: root@mozart:~# /etc/init.d/unattended-upgrades start Checking for running unattended-upgrades: root@mozart:~# Something seems to be broken, but I'm not sure why. I have pending updates and they are not being applied: root@mozart:~# aptitude safe-upgrade Reading package lists... Done Building dependency tree Reading state information... Done Reading extended state information Initializing package states... Done The following packages will be upgraded: linux-libc-dev 1 packages upgraded, 0 newly installed, 0 to remove and 0 not upgraded. Need to get 0B/743kB of archives. After unpacking 4096B will be used. Do you want to continue? [Y/n/?] In all the servers I have, unattended upgrades seems to have been disabled: root@mozart:~# apt-config shell UnattendedUpgradeInterval APT::Periodic::Unattended-Upgrade root@mozart:~# Any ideas what am I missing?

    Read the article

  • Update BIOS on Sun Fire X4150 server

    - by Massimo
    I have some Sun Fire X4150 servers with a very old BIOS release (1ADQW015), which seems to have some compatibility problems with WMware ESX Server 3.5 and Windows 2008 R2 virtual machines; so I want to update the BIOS on them. The problem: according to this page, if your servers run ELOM (mine do), you first need to update to the latest ELOM release, then to the interim transition release, then finally you can update to the latest one. Ok, I'm willing to do that... but it looks like Sun (now Oracle) will happily let you download the latest firmware DVD (3.3.0), but it will not let you download the transition release (2.0) if you don't have a support contract. Well, I actuall don't care at all about the servers' management controllers (we don't even use them), so upgrading from ELOM to ILOM is totally irrelevant to me; but I need to update the servers' BIOS. So my question is: can I update the servers' BIOS to the latest version without doing the full ELOM-to-ILOM migration, or will this not work (or even make the servers unusable)? Do BIOS versions and SP ones need to be matched, or can one be updated without bothering with the other? Bonus question: if this whole ELOM-to-ILOM thing actually is needed in order to update the BIOS, can that 2.0 CD-ROM be obtained without having a support contract with Sun/Oracle (which we are definitely not going to sign, being that quite old hardware)? Update: I tried upgrading only the BIOS on one of the servers, and it didn't boot anymore. So it really looks like a full firmware upgrade is needed, and the management controller and BIOS versions should be kept in sync. So... where can I find that *&!£%$% 2.0 CD-ROM? Or at least the transition firmware that can be found on it?

    Read the article

  • PowerPoint avoid animation completion on click & advance slide or start new one

    - by ScottS
    Scenario I have PowerPoint 2010 On the "Transitions" tab the "Advance Slide On Mouse Click" check box is checked. I have a long, slow, timed, non-repeating animation working in the background of the slide. I click to advance the slide before the animation is finished, but ... Instead of advancing the slide, the animation moves to the completed state ... Forcing a second click to actually advance the slide. Additionally If I have other animations on the slide that are initiated by a click, the long animation also advances to a finished state before starting the new animation. Desired Behavior On click, I want the slide to advance or the next on-click animation to start whether the long animation is done or not, and without having that long animation first "complete" itself. In the case of another animation, I simply want the long animation to continue, while also doing the new animation. Ultimate Question Is there a way to either: Set an option somewhere to not have that animation complete on click and simply "continue" to animate with the start of a new animation or to advance the slide (as the case may be)? Create a VBA script that will produce the desired behavior for the long animation?

    Read the article

  • SQL Server Database In Single User Mode after Failover

    - by jlichauc
    Here is a weird situation we experienced with a SQL Server 2008 Database Mirroring Failover. We have a pair of mirrored databases running in high-availability mode and both the principal and mirror showed as synchronized. As part of some maintenance I triggered a manual failover of the principal to the mirror. However after the failover the principal was now in single-user mode instead of the expected "Principal/Synchronized" state we usually get. The database had been in multi-user mode on the previous principal before this had happened. We ended up stopping all applications, restarting the SQL Server instances, and executing "ALTER DATABASE ... SET MULTI_USER" to bring the database back to the expected "Principal/Synchronized" state in a multi-user mode. Question. Does anyone know where SQL Server stores information about whether a database should be in single-user mode or not? I'm wondering if there is some system database or table that has this setting recorded somewhere. In particular we had an incident once with the database on the original principal (the one I was failing over to) where when trying to detach the database it was put into single-user mode. I'm wondering if that setting is cached somewhere and is the reason that SQL Server put it back into single-user mode after a failover.

    Read the article

  • What do the readonly attributes in diskpart really mean?

    - by marzipan
    I am wondering exactly what the meaning is of the "Read-only" disk and volume attributes that you can twiddle in diskpart on Windows 7. I am trying to set up an external USB drive as an installation medium for my own software, so I'd like to protect it against casual or inadvertent changes by users who it is given to, so they don't screw up the installation files they might need in the future. From what I can tell by experimentation with diskpart, the volume read-only attribute is actually stored on the physical disk somewhere, because I can set it and it shows up when I take the drive to another machine. This is great because my users can't (easily) change any of the files on the volume, or format it from Windows explorer. However, the disk read-only attribute seems to be just an aspect of how the current machine is accessing the drive. When I set it I can no longer delete the volume in the disk via Disk Management, but when I take the drive to another machine, the attribute is no longer set and in Disk Management I can delete the volume on the disk. I guess I'm not that worried about my users doing that, but I am annoyed that I don't understand what these attributes are really doing. Another thing that I don't understand is that the "volume" read-only attribute actually seems to be global to the disk - if I have two volumes on the disk, and I set the readonly flag on one of them, then it gets set on the other one too. ?!? I have the feeling I'm not searching for the right docs - all I'm finding is diskpart docs that give the syntax for twiddling these attributes, not what they really mean. Any pointers would be very welcome! Thanks, Asa

    Read the article

  • Why my internal hard disk can be ejected?

    - by Bear Bear
    I have 6 hard disks in my computer and one DVD. The disk that I connect to the 6th SATA port is a regular disk. But my Windows 7 64 bit shows it as a removable drive. I can eject my hard disk! Just like a pen drive. If I connect another disk to the 6th port, I can eject that disk too. So it has nothing to do with the physical disk, it must be something related to Windows or BIOS I don't understand why Windows 7 is seeing a normal hard disk as removable. In Computer Management - Disk Management, the disk looks identical to the others - there is nothing there to suggest the drive is different from the others. But in the tray I have the icon to eject it. The motherboard model is ASUS F2A85 V PRO FM2. All the disks are formatted normally, no Dynamic Disk, no RAID, nothing special. How can I tell Windows 7 to treat the disk exactly like the others, so it can't be ejected?

    Read the article

  • ZFS with L2ARC (SSD) slower for random seeks than without L2ARC

    - by Florian Kruse
    I am currently testing ZFS (Opensolaris 2009.06) in an older fileserver to evaluate its use for our needs. Our current setup is as follows: Dual core (2,4 GHz) with 4 GB RAM 3x SATA controller with 11 HDDs (250 GB) and one SSD (OCZ Vertex 2 100 GB) We want to evaluate the use of a L2ARC, so the current ZPOOL is: $ zpool status pool: tank state: ONLINE scrub: none requested config: NAME STATE READ WRITE CKSUM afstank ONLINE 0 0 0 raidz1 ONLINE 0 0 0 c11t0d0 ONLINE 0 0 0 c11t1d0 ONLINE 0 0 0 c11t2d0 ONLINE 0 0 0 c11t3d0 ONLINE 0 0 0 raidz1 ONLINE 0 0 0 c13t0d0 ONLINE 0 0 0 c13t1d0 ONLINE 0 0 0 c13t2d0 ONLINE 0 0 0 c13t3d0 ONLINE 0 0 0 cache c14t3d0 ONLINE 0 0 0 where c14t3d0 is the SSD (of course). We run IO tests with bonnie++ 1.03d, size is set to 200 GB (-s 200g) so that the test sample will never be completely in ARC/L2ARC. The results without SSD are (average values over several runs which show no differences) write_chr write_blk rewrite read_chr read_blk random seeks 101.998 kB/s 214.258 kB/s 96.673 kB/s 77.702 kB/s 254.695 kB/s 900 /s With SSD it becomes interesting. My assumption was that the results should be in worst case at least the same. While write/read/rewrite rates are not different, the random seek rate differs significantly between individual bonnie++ runs (between 188 /s and 1333 /s so far), average is 548 +- 200 /s, so below the value w/o SSD. So, my questions are mainly: Why do the random seek rates differ so much? If the seeks are really random, they should not differ much (my assumption). So, even if the SSD is impairing the performance it should be the same in each bonnie++ run. Why is the random seek performance worse in most of the bonnie++ runs? I would assume that some part of the bonnie++ data is in the L2ARC and random seeks on this data performs better while random seeks on other data just performs similarly like before.

    Read the article

  • IP-dependent local port-forwarding on Linux

    - by chronos
    I have configured my server's sshd to listen on a non-standard port 42. However, at work I am behind a firewall/proxy, which only allow outgoing connections to ports 21, 22, 80 and 443. Consequently, I cannot ssh to my server from work, which is bad. I do not want to return sshd to port 22. The idea is this: on my server, locally forward port 22 to port 42 if source IP is matching the external IP of my work's network. For clarity, let us assume that my server's IP is 169.1.1.1 (on eth1), and my work external IP is 169.250.250.250. For all IPs different from 169.250.250.250, my server should respond with an expected 'connection refused', as it does for a non-listening port. I'm very new to iptables. I have briefly looked through the long iptables manual and these related / relevant questions: http://serverfault.com/questions/57872/iptables-question-forwarding-port-x-to-an-ssh-port-of-different-machine-on-the-n http://serverfault.com/questions/140622/how-can-i-port-forward-with-iptables However, those questions deal with more complicated several-host scenarios, and it is not clear to me which tables and chains I should use for local port-forwarding, and if I should have 2 rules (for "question" and "answer" packets), or only 1 rule for "question" packets. So far I have only enabled forwarding via sysctl. I will start testing solutions tomorrow, and will appreciate pointers or maybe case-specific examples for implementing my simple scenario. Is the draft solution below correct? iptables -A INPUT [-m state] [-i eth1] --source 169.250.250.250 -p tcp --destination 169.1.1.1:42 --dport 22 --state NEW,ESTABLISHED,RELATED -j ACCEPT Should I use the mangle table instead of filter? And/or FORWARD chain instead of INPUT?

    Read the article

  • IIS serving pages extremely slowly

    - by mos
    TL;DR: IIS 7 on WS2008R2 serves pages really slowly; everyone assumes it's because it's IIS and we should have gone with an Apache solution on Linux. I have no idea where to start debugging the problem. I work in a nearly all-MS shop with a bunch of fellow programmers who think Linux is the One True Way. Management recently added a Windows machine with IIS to serve Target Process (third-party agile system), but the site runs extremely slowly. Everyone, to a man, assumes it's because it's on IIS, and if only management would grow a brain and get some Linux servers in here, we could really start cleaning things up! ...Right. Everyone "knows" IIS isn't fit to serve .txt files. ...Well, as the only non-Microsoft hater in the bunch, I am apparently the only one who thinks maybe the Linux guy who hated being told to set up the IIS server may have screwed things up. I'd like to go fix it, but I don't have any clue as to where to start as I am not a sys admin. Help?

    Read the article

  • keepalived issues on xen domU

    - by David Cournapeau
    Hi, I cannot manage to run keepalived correctly on xen domU. I am following this link for configuration, and it works great on some local VM (running with KVM). If I set up the exact same configuration, but on xen domU, it does not work: both servers do not see each other and decide to be master (10.120.100.99 being the virtual IP) $ sudo ip addr sh eth0 # host1 2: eth0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc pfifo_fast state UP qlen 1000 link/ether 00:16:3e:78:f5:31 brd ff:ff:ff:ff:ff:ff inet 10.120.100.104/24 brd 10.120.100.255 scope global eth0 inet 10.120.100.99/32 scope global eth0 inet6 fe80::216:3eff:fe78:f531/64 scope link valid_lft forever preferred_lft forever $ sudo ip addr sh eth0 # host2 2: eth0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc pfifo_fast state UP qlen 1000 link/ether 00:16:3e:51:36:20 brd ff:ff:ff:ff:ff:ff inet 10.120.100.105/24 brd 10.120.100.255 scope global eth0 inet 10.120.100.99/32 scope global eth0 inet6 fe80::216:3eff:fe51:3620/64 scope link valid_lft forever preferred_lft forever Is there a way I could debug this - it seems some people are able to use keepalived on xen following some mailing list, but without much info on their config.

    Read the article

  • cannot connect to <server_name>\sqlexpress

    - by Jackson Sunuwar
    I have tried disabling firing wall and checked sqlbrowser is started but for some reason I cannnot connect to my datbase... called server_name\sqlexpress.. I have a virtual machine and a full scale MS SQL Server 2008 R2 running on it... and I have several other vm running sqlexpress. they run fine and I can connect to them using sqlexpress... but when i try to access from sqlserver... I get this error. A network-related or instance-specific error occurred while establishing a connection to SQL Server. The server was not found or was not accessible. Verify that the instance name is correct and that SQL Server is configured to allow remote connections. (provider: SQL Network Interfaces, error: 26 - Error Locating Server/Instance Specified) (Microsoft SQL Server, Error: -1) Digging deep into the error, I found this Error Number: -1 Severity: 20 State: 0 and finally this... Program Location: at System.Data.SqlClient.SqlInternalConnection.OnError(SqlException exception, Boolean breakConnection) at System.Data.SqlClient.TdsParser.ThrowExceptionAndWarning(TdsParserStateObject stateObj) at System.Data.SqlClient.TdsParser.Connect(ServerInfo serverInfo, SqlInternalConnectionTds connHandler, Boolean ignoreSniOpenTimeout, Int64 timerExpire, Boolean encrypt, Boolean trustServerCert, Boolean integratedSecurity, SqlConnection owningObject) at System.Data.SqlClient.SqlInternalConnectionTds.AttemptOneLogin(ServerInfo serverInfo, String newPassword, Boolean ignoreSniOpenTimeout, Int64 timerExpire, SqlConnection owningObject) at System.Data.SqlClient.SqlInternalConnectionTds.LoginNoFailover(String host, String newPassword, Boolean redirectedUserInstance, SqlConnection owningObject, SqlConnectionString connectionOptions, Int64 timerStart) at System.Data.SqlClient.SqlInternalConnectionTds.OpenLoginEnlist(SqlConnection owningObject, SqlConnectionString connectionOptions, String newPassword, Boolean redirectedUserInstance) at System.Data.SqlClient.SqlInternalConnectionTds..ctor(DbConnectionPoolIdentity identity, SqlConnectionString connectionOptions, Object providerInfo, String newPassword, SqlConnection owningObject, Boolean redirectedUserInstance) at System.Data.SqlClient.SqlConnectionFactory.CreateConnection(DbConnectionOptions options, Object poolGroupProviderInfo, DbConnectionPool pool, DbConnection owningConnection) at System.Data.ProviderBase.DbConnectionFactory.CreateNonPooledConnection(DbConnection owningConnection, DbConnectionPoolGroup poolGroup) at System.Data.ProviderBase.DbConnectionFactory.GetConnection(DbConnection owningConnection) at System.Data.ProviderBase.DbConnectionClosed.OpenConnection(DbConnection outerConnection, DbConnectionFactory connectionFactory) at System.Data.SqlClient.SqlConnection.Open() at Microsoft.SqlServer.Management.SqlStudio.Explorer.ObjectExplorerService.ValidateConnection(UIConnectionInfo ci, IServerType server) at Microsoft.SqlServer.Management.UI.ConnectionDlg.Connector.ConnectionThreadUser() Firewall is turned off on the VM that's running mssqlserver... I turned of firewall on one of the vm that's running the sqlexpress but I still get the error... can someone please help... thank you

    Read the article

  • Samba4/Ubuntu Shares Incorrectly Available to All Users

    - by Dan
    I've got my Ubuntu server working with Samba4 and got it set up as the Primary domain controller on my network with AD and all that goodness. However, I'm trying to get my Samba configuration to work with the users and groups I've defined with the Active Directory tools from Windows. For instance, I've got a share X which I want users A and B (as part of the 'management' group, known as LLGrpManager in my setup) to see, but no body else. However, after making changes to the configuration, restarting Samba, I test by connecting to the share with my Mac over Samba as user 'C' which isn't part of the management group, and I can, incorrectly, see the X share. I've tried alsorts of combinations of specifying the group with no luck at all. I've got a feeling that my global config might be too lenient or something to do with file permissions but being a bit green, I'm without clue. My /etc/samba/smb.conf # Global parameters [global] server role = domain controller server string = Office Server workgroup = LLDOMAIN realm = lldomain.local netbios name = DUMBO passdb backend = samba4 logon path = \\%L\profiles\%U logon drive = L: log file = /var/log/samba/%m.log max log size = 50 security = ads domain logons = yes domain master = auto usershare allow guests = no valid users = %S [netlogon] path = /var/lib/samba/sysvol/lldomain.local/scripts read only = no guest ok = no [sysvol] path = /var/lib/samba/sysvol read only = No guest ok = no valid users = @LLDOMAIN\LLGrpManager [ShareX] path = /data comment = Entire Data Volume guest ok = no comment = Entire Data Volume guest ok = no valid users = @LLDOMAIN\LLGrpManager admin users = @LLDOMAIN\LLGrpManager browsable = no inherit acls = yes inherit permissions = yes ... My /etc/nsswitch.conf I've also instructed the system to use the nss winbind library when searching for users or groups by adding the stanza passwd and group in /etc/nsswitch.conf: passwd: compat winbind group: compat winbind shadow: compat Permissions on the folder in question drwxrwxrwt 8 root root 4.0K Oct 28 19:11 data

    Read the article

  • get-eventlog issue

    - by Jim B
    I wanted to get a quick report of some log entries I saw on a server, so I ran: Get-Eventlog -logname system -newest 10 -computer fs1 | fl I got events back however the descriptions were all wrong. Here's an example: Index : 1260055 EntryType : Warning InstanceId : 2186936367 Message : The description for Event ID '-2108030929' in Source 'W32Time' cannot be found. The local compute r may not have the necessary registry information or message DLL files to display the message, or you may not have permission to access them. The following information is part of the event:'time. windows.com,0x1' Category : (0) CategoryNumber : 0 ReplacementStrings : {time.windows.com,0x1} Source : W32Time TimeGenerated : 1/25/2010 10:43:31 AM TimeWritten : 1/25/2010 10:43:31 AM UserName : Note that if I pull the event ID property it's correct (in this case 38) Is this is known issue or is something wrong. The messages resolve fine via event viewer locally and remotely Here is the powershell version info: Name : ConsoleHost Version : 2.0 InstanceId : bc58fcf8-bba3-4ca8-8972-17dbd5d9ff08 UI : System.Management.Automation.Internal.Host.InternalHostUserInterface CurrentCulture : en-US CurrentUICulture : en-US PrivateData : Microsoft.PowerShell.ConsoleHost+ConsoleColorProxy IsRunspacePushed : False Runspace : System.Management.Automation.Runspaces.LocalRunspace Here is the revised version info: Name Value ---- ----- CLRVersion 2.0.50727.3603 BuildVersion 6.0.6002.18111 PSVersion 2.0 WSManStackVersion 2.0 PSCompatibleVersions {1.0, 2.0} SerializationVersion 1.1.0.1 PSRemotingProtocolVersion 2.1

    Read the article

  • SharePoint extranet security concerns, am I right to be worried?

    - by LukeR
    We are currently running MOSS 2007 internally, and have been doing so for about 12 months with no major issues. There has now been a request from management to provide access from the internet for small groups (initially) which are comprised of members from other Community Organisations like ours. Committees and the like. My first reaction was not joy when presented with this request, however I'd like to make sure the apprehension is warranted. I have read a few docs on TechNet about security hardening with regard to SharePoint, but I'm interested to know what others have done. I've spoken with another organisation who has already implemented something similar, and they have essentially port-forwarded from the internet to their internal production MOSS server. I don't really like the sound of this. Is it adviseable/necessary to run a DMZ type configuration, with a separate web front-end on a contained network segment? Does that even offer me any greater security than their setup? Some of the configurations from a TechNet doc aren't really feasible, given our current network budget. I've already made my concerns known to management, but it appears it will go ahead in some form or another. I'm tempted to run a completely isolated, seperate install just for these types of users. Should I even be concerned about it? Any thoughts, comments would be most welcomed at this point.

    Read the article

  • Juniper’s Network Connect ncsvc on Linux: “host checker failed, error 10”

    - by hfs
    I’m trying to log in to a Juniper VPN with Network Connect from a headless Linux client. I followed the instructions and used the script from http://mad-scientist.us/juniper.html. When running the script with --nogui switch the command that gets finally executed is $HOME/.juniper_networks/network_connect/ncsvc -h HOST -u USER -r REALM -f $HOME/.vpn.default.crt. I get asked for the password, a line “Connecting to…” is printed but then the programm silently stops. When adding -L 5 (most verbose logging) to the command line, these are the last messages printed to the log: dsclient.info state: kStateCacheCleaner (dsclient.cpp:280) dsclient.info --> POST /dana-na/cc/ccupdate.cgi (authenticate.cpp:162) http_connection.para Entering state_start_connection (http_connection.cpp:282) http_connection.para Entering state_continue_connection (http_connection.cpp:299) http_connection.para Entering state_ssl_connect (http_connection.cpp:468) dsssl.para SSL connect ssl=0x833e568/sd=4 connection using cipher RC4-MD5 (DSSSLSock.cpp:656) http_connection.para Returning DSHTTP_COMPLETE from state_ssl_connect (http_connection.cpp:476) DSHttp.debug state_reading_response_body - copying 0 buffered bytes (http_requester.cpp:800) DSHttp.debug state_reading_response_body - recv'd 0 bytes data (http_requester.cpp:833) dsclient.info <-- 200 (authenticate.cpp:194) dsclient.error state host checker failed, error 10 (dsclient.cpp:282) ncapp.error Failed to authenticate with IVE. Error 10 (ncsvc.cpp:197) dsncuiapi.para DsNcUiApi::~DsNcUiApi (dsncuiapi.cpp:72) What does host checker failed mean? How can I find out what it tried to check and what failed? The HostChecker Configuration Guide mentions that a $HOME/.juniper_networks/tncc.jar gets installed on Linux, but my installation contains no such file. From that I concluded that HostChecker is disabled for my VPN on Linux? Are the POST to /dana-na/cc/ccupdate.cgi and “host checker failed” connected or independent? By running the connection over a SSL proxy I found out that the POST data is status=NOTOK (Funny side note: the client of the oh-so-secure VPN does not validate the server’s SSL certificate, so is wide open to MITM attacks…). So it seems that it’s the client that closes the connection and not the server.

    Read the article

  • How to create a software raid5 array without a spare

    - by Yannick M.
    I am trying to create a software raid5 array using mdadm: $ linux # mdadm --create --verbose /dev/md0 --level=5 --raid-devices=4 --spare-devices=0 /dev/sda1 /dev/sdb1 /dev/sdc1 /dev/sdd1 mdadm: layout defaults to left-symmetric mdadm: chunk size defaults to 64K mdadm: array /dev/md0 started. However when inspecting /proc/mdstat Personalities : [raid6] [raid5] [raid4] md0 : active raid5 sdd1[4] sdc1[2] sdb1[1] sda1[0] 2930279808 blocks level 5, 64k chunk, algorithm 2 [4/3] [UUU_] [>....................] recovery = 0.3% (2970496/976759936) finish=186.1min speed=87172K/sec unused devices: <none> It seems one drive isn't active, so I check the details of the array: /dev/md0: Version : 00.90.03 Creation Time : Tue Jul 21 16:29:53 2009 Raid Level : raid5 Array Size : 2930279808 (2794.53 GiB 3000.61 GB) Used Dev Size : 976759936 (931.51 GiB 1000.20 GB) Raid Devices : 4 Total Devices : 4 Preferred Minor : 0 Persistence : Superblock is persistent Update Time : Tue Jul 21 16:29:53 2009 State : clean, degraded, recovering Active Devices : 3 Working Devices : 4 Failed Devices : 0 Spare Devices : 1 Layout : left-symmetric Chunk Size : 64K Rebuild Status : 0% complete UUID : ce8b2f40:821d003c:0027688e:a70977ec Events : 0.1 Number Major Minor RaidDevice State 0 8 1 0 active sync /dev/sda1 1 8 17 1 active sync /dev/sdb1 2 8 33 2 active sync /dev/sdc1 4 8 49 3 spare rebuilding /dev/sdd1 And it seems there are only 3 active devices, with one spare. Is it just me, or something wrong here?

    Read the article

  • Raid-z unaccessible after putting one disk offline

    - by varesa
    I have installed FreeNAS on a test server, with 3x 1Tb drives. They are setup in raidz. I tried to offline one of the disks (from the FreeNAS web-ui), and the array became degraded, as I think it should. The problem is with the array becoming unaccessible after that. I thought a raid like that should be able to run fine with one of the disks missing. Atleast very soon after I offline'd and pulled out the disk, the iSCSI share disappeared from a ESXi host's datastores. I also ssh'd into the FreeNAS server, and tried just executing ls /mnt/raid (/mnt/raid/ being the mount point). The whole terminal froze, not accepting ^C or anything. # zpool status -v pool: raid state: DEGRADED status: One or more devices are faulted in response to IO failures. action: Make sure the affected devices are connected, then run 'zpool clear'. see: http://www.sun.com/msg/ZFS-8000-HC scrub: none requested config: NAME STATE READ WRITE CKSUM raid DEGRADED 1 30 0 raidz1 DEGRADED 4 56 0 gptid/c8c9e44c-08e1-11e2-9ba6-001b212a83ea ONLINE 3 60 0 gptid/c96f32d5-08e1-11e2-9ba6-001b212a83ea ONLINE 3 63 0 gptid/ca208205-08e1-11e2-9ba6-001b212a83ea OFFLINE 0 0 0 errors: Permanent errors have been detected in the following files: /mnt/raid/ raid/iscsivol:<0x0> raid/iscsivol:<0x1> Have I understood the workings of a raidz wrong, or is there something else going on? It would not be nice to have the same thing happen on a production system...

    Read the article

  • Which events specifically cause Windows 2008 to mark a SAN volume offline?

    - by Jeremy
    I am searching for specific criteria/events that will cause Windows 2008 to mark a SAN volume as offline in disk management, even though it is connected to that SAN volume via FC or iSCSI. Microsoft states that "A dynamic disk may become Offline if it is corrupted or intermittently unavailable. A dynamic disk may also become Offline if you attempt to import a foreign (dynamic) disk and the import fails. An error icon appears on the Offline disk. Only dynamic disks display the Missing or Offline status." I am specifically wondering if, on the SAN, changing the path to the disk (such as the disk being presented to the host via a different iSCSI target IQN or a different LUN #) would cause a volume to be offlined in disk management. Thanks! Edit: I have already found two reasons why a disk might be set offline, disk signature collisions and the SAN disk policy. Bounty would be awarded to someone who can find further documented reasons related to changes in the volume's path. Disk signature collisions: http://blogs.technet.com/b/markrussinovich/archive/2011/11/08/3463572.aspx SAN disk policy: http://jeffwouters.nl/index.php/2011/06/disk-offline-with-error-the-disk-is-offline-because-of-a-policy-set-by-an-administrator/

    Read the article