Search Results

Search found 10941 results on 438 pages for 'location'.

Page 385/438 | < Previous Page | 381 382 383 384 385 386 387 388 389 390 391 392  | Next Page >

  • Mono through FastCGI on nginx

    - by Stijn
    I'm going through http://www.mono-project.com/FastCGI_Nginx and can't get it to work. The FastCGI server seems to be running. The following is from the error log: upstream sent unexpected FastCGI record: 3 while reading response header from upstream, client: 192.168.1.125, server: arch, request: "GET /Default.aspx HTTP/1.1", upstream: "fastcgi://127.0.0.1:9000", host: "arch" Command used to start the server (I've tried server2 and server4, using a simple .NET 2.0 or .NET 4.0 project): fastcgi-mono-server2 /applications=arch:/:/var/www/test/public/ /socket=tcp:127.0.0.1:9000 /stopable=True nginx config: server { listen 80; server_name arch; access_log /var/www/test/log/access.log; error_log /var/www/test/log/error.log; location / { root /var/www/test/public; index index.html index.htm default.aspx Default.aspx; fastcgi_index Default.aspx; fastcgi_pass 127.0.0.1:9000; fastcgi_param PATH_INFO ""; fastcgi_param SCRIPT_FILENAME $document_root$fastcgi_script_name; } } Using xsp4 works fine, I can browse the site. I've enabled FastCGI logging, this is the output: [2012-04-15 23:51:18Z] Debug Accepting an incoming connection. [2012-04-15 23:51:18Z] Notice Beginning to receive records on connection. [2012-04-15 23:51:18Z] Debug Record received. (Type: BeginRequest, ID: 1, Length: 8) [2012-04-15 23:51:18Z] Debug Record received. (Type: Params, ID: 1, Length: 386) [2012-04-15 23:51:18Z] Debug Record received. (Type: Params, ID: 1, Length: 0) [2012-04-15 23:51:18Z] Debug Read parameter. (PATH_INFO = ) [2012-04-15 23:51:18Z] Debug Read parameter. (SCRIPT_FILENAME = /var/www/test/public/Home) [2012-04-15 23:51:18Z] Debug Read parameter. (HTTP_HOST = arch) [2012-04-15 23:51:18Z] Debug Read parameter. (HTTP_USER_AGENT = Mozilla/5.0 (Windows NT 6.1; WOW64; rv:11.0) Gecko/20100101 Firefox/11.0) [2012-04-15 23:51:18Z] Debug Read parameter. (HTTP_ACCEPT = text/html,application/xhtml+xml,application/xml;q=0.9,*/*;q=0.8) [2012-04-15 23:51:18Z] Debug Read parameter. (HTTP_ACCEPT_LANGUAGE = en-gb,en;q=0.5) [2012-04-15 23:51:18Z] Debug Read parameter. (HTTP_ACCEPT_ENCODING = gzip, deflate) [2012-04-15 23:51:18Z] Debug Read parameter. (HTTP_CONNECTION = keep-alive) [2012-04-15 23:51:18Z] Debug Read parameter. (HTTP_COOKIE = ASP.NET_SessionId=2C3D702C9B0F23F69B80820B) [2012-04-15 23:51:18Z] Error Failed to process connection. Reason: Argument cannot be null. Parameter name: s [2012-04-15 23:51:18Z] Debug Record sent. (Type: EndRequest, ID: 1, Length: 8) [2012-04-15 23:51:18Z] Debug The FastCGI connection has been closed.

    Read the article

  • DPM 2010 PowerShell Script to Easily Restore Multiple Files

    - by bmccleary
    I’ve got what I thought would be a simple task with Data Protection Manager 2010 that is turning out to be quite frustrating. I have a file server on one server and it is the only server in a protection group. This file server is the repository for a document management application which stores the files according to the data within a SQL database. Sometimes users inadvertently delete files from within our application and we need to restore them. We have all the information needed to restore the files to include the file name, the folder that the file was stored in and the exact date that the file was deleted. It is easy for me to restore the file from within the DPM console since we have a recovery point created every day, I simply go to the day before the delete, browse to the proper folder and restore the file. The problem is that using the DPM console, the cumbersome wizard requires about 20 mouse clicks to restore a single file and it takes 2-4 minutes to get through all the windows. This becomes very irritating when a client needs 100’s of files restored… it takes all day of redundant mouse clicks to restore the files. Therefore, I want to use a PowerShell script (and I’m a novice at PowerShell) to automate this process. I want to be able to create a script that I pass in a file name, a folder, a recovery point date (and a protection group/server name if needed) and simply have the file restored back to its original location with some sort of success/failure notification. I thought it was a simple basic task of a backup solution, but I am having a heck of a time finding the right code. I have seen the sample code at http://social.technet.microsoft.com/wiki/contents/articles/how-to-use-a-windows-powershell-script-to-recover-an-item-in-data-protection-manager.aspx that I have tried to follow, but it doesn’t accomplish what I really want to do (it’s too simplistic) and there are errors in the sample code. Therefore, I would like to get some help writing a script to restore these files. An example of the known values to restore the data are: DPM Server: BACKUP01 Protection Group: Document Repository Data Protected Server: FILER01 File Path: R:\DocumentRepository\ToBackup\ClientName\Repository\2010\07\24\filename.pdf Date Deleted: 8/2/2010 (last recovery point = 8/1/2010) Bonus Points: If you can help me not only create this script, but also show me how to automate by providing a text file with the above information that the PowerShell script loops through, or even better, is able to query our SQL server for the needed data, then I would be more than willing to pay for this development.

    Read the article

  • Proxying webmin with nginx

    - by TheLQ
    I am attempting to proxy webmin behind nginx for various reasons that are outside the scope of this question. However I've been trying for a while now and can't seem to figure it out and think I'm to the point where I've exhausted all the permutations of the config file I can think of. What I have now: relevant nginx config (commented out options removed, I tried many) # Proxy for webmin location /admin/quackwall-webmin { proxy_pass http://127.0.0.1:10000; # Also tried ending with /admin/quackwall-webmin proxy_set_header Host $host; } /etc/webmin/config - Relevant parts webprefix=/admin/quackwall-webmin webprefixnoredir=1 referer=(nginx domain name) Webmin itself is on the standard ports, listening on all addresses temporarily for debugging. SSL has been disabled for right now. So I make a standard request for the login page. However all the CSS and images are broken, with the standard login page returned for all of the resources. In the webmin miniserv logs I see 127.0.0.1 - - [29/Oct/2012:12:29:00 -0400] "GET /admin/quackwall-webmin/session_login.cgi HTTP/1.0" 401 2453 127.0.0.1 - - [29/Oct/2012:12:29:01 -0400] "GET /admin/quackwall-webmin/unauthenticated/style.css HTTP/1.0" 401 2453 127.0.0.1 - - [29/Oct/2012:12:29:01 -0400] "GET /admin/quackwall-webmin/unauthenticated/sorttable.js HTTP/1.0" 401 2453 127.0.0.1 - - [29/Oct/2012:12:29:01 -0400] "GET /admin/quackwall-webmin/unauthenticated/toggleview.js HTTP/1.0" 401 2453 So all the URL's are returning 401s. Interestingly ngrep seems to show that the requests suceeded on the backend communication between nginx and webmin T 127.0.0.1:58908 -> 127.0.0.1:10000 [AP] POST /admin/quackwall-webmin/session_login.cgi HTTP/1.0..Host: (host)..Connection: close..User-Agent: Mozilla/5.0 (Windows NT 6.1; WOW 64; rv:16.0) Gecko/20100101 Firefox/16.0..Accept: text/html,application/xhtml+xml,application/xml;q=0.9,*/*;q=0.8..Accept-Language: en-US,en;q=0.5. .Accept-Encoding: gzip, deflate..Referer: http://(host)/admin/quackwall-webmin/session_login.cgi..Cookie: testing=1..Cache-Control: ma x-age=0..Content-Type: application/x-www-form-urlencoded..Content-Length: 41....page=%2F&user=(user)&pass=(pass) T 127.0.0.1:10000 -> 127.0.0.1:58908 [AP] HTTP/1.0 200 Document follows.. Various other permutations of these config options and others show similar results, with the URL sent to webmin by nginx either being /admin/quackwall-webmin/session_login.cgi, /admin/quackwall-webmin//session_login.cgi, and just /session_login.cgi. All give 201 Unauthenticated responses. All requests, even those that somewhat succeed (as in I can actually load the resources of the page) Is changing the webprefix in webmin even supported? What am I doing wrong? What else can I try?

    Read the article

  • Windows 7 Complete PC Backup - Fails with error code: 0x80070002

    - by leeand00
    While doing a Complete PC Backup in Windows 7 I received dialog reading: Windows Backup...error The backup did not complete successfully. Open the Backup and Restore Control Panel to view settings From there I clicked the Options button. Windows Backup: Troubleshooting Options Check your backup Windows Backup encountered invalid MediaID.bin file on the drive where the backup is saved. Restore from a different backup or delete the MediaID.bin file and try to create another backup. The MediaID.bin file can be found under \MediaID.Bin & \\MediaId.Bin. I deleted the file in question (MediaID.bin) from X:\ (one of the drives being backedup( and tried the backup again. Next I was presented with a dialog that read: Windows Backups: Troubleshooting Options Check your backup The system connot find the file specified. Try to run backup again Change backup settings Backup Time: 2/10/2010 12:17 PM Backup location: FreeAgent Drive (E:) Error code: 0x80070002 Additionally I checked the error log and I found this: <Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event"> <System> <Provider Name="Windows Backup" /> <EventID Qualifiers="0">4104</EventID> <Level>2</Level> <Task>0</Task> <Keywords>0x80000000000000</Keywords> <TimeCreated SystemTime="2010-02-10T17:17:48.000000000Z" /> <EventRecordID>5107</EventRecordID> <Channel>Application</Channel> <Computer>leeand00-PC</Computer> <Security /> </System> - <EventData> <Data>The system cannot find the file specified. (0x80070002)</Data> <Binary>02000780E30500003F0900005B090000420ED1665C2BEE174B64529CB14610EA71000000</Binary> </EventData> </Event> Viewed the following document: http://blogs.technet.com/filecab/archive/2008/03/12/common-causes-and-solutions-to-backup-system-restore-and-complete-pc-backup-problems-updated.aspx searched for 0x80070002 and tried and follow the directions... I noticed that none of the profiles was missing a ProfileImagePath, I also noticed that the people commenting on the page said that they weren't missing it either. I'm currently trying the backup again, but this time I unchecked all of the user's profiles and opted only to backup the two drives X: and C: on to E:\ I'll let you know what happens. Any ideas?

    Read the article

  • error while installing the libmemcached

    - by Ahmet vardar
    I get this while installing libmemcached root@server [/libmemcached]# make make all-am make[1]: Entering directory `/libmemcached' if /bin/sh ./libtool --tag=CXX --mode=compile g++ -DHAVE_CONFIG_H -I. -I. -I. -I. -I. -ggdb -DBUILDING_HASHKIT -MT libhashkit/libhashkit_libhashkit_la-aes.lo -MD -MP -MF "libhashkit/.deps/libhashkit_libhashkit_la-aes.Tpo" -c -o libhashkit/libhashkit_libhashkit_la-aes.lo `test -f 'libhashkit/aes.cc' || echo './'`libhashkit/aes.cc; \ then mv -f "libhashkit/.deps/libhashkit_libhashkit_la-aes.Tpo" "libhashkit/.deps/libhashkit_libhashkit_la-aes.Plo"; else rm -f "libhashkit/.deps/libhashkit_libhashkit_la-aes.Tpo"; exit 1; fi ./libtool: line 866: X--tag=CXX: command not found ./libtool: line 899: libtool: ignoring unknown tag : command not found ./libtool: line 866: X--mode=compile: command not found ./libtool: line 1032: *** Warning: inferring the mode of operation is deprecated.: command not found ./libtool: line 1033: *** Future versions of Libtool will require --mode=MODE be specified.: command not found ./libtool: line 1176: Xg++: command not found ./libtool: line 1176: X-DHAVE_CONFIG_H: command not found ./libtool: line 1176: X-I.: command not found ./libtool: line 1176: X-I.: command not found ./libtool: line 1176: X-I.: command not found ./libtool: line 1176: X-I.: command not found ./libtool: line 1176: X-I.: command not found ./libtool: line 1176: X-ggdb: command not found ./libtool: line 1176: X-DBUILDING_HASHKIT: command not found ./libtool: line 1176: X-MT: command not found ./libtool: line 1176: Xlibhashkit/libhashkit_libhashkit_la-aes.lo: No such file or directory ./libtool: line 1176: X-MD: command not found ./libtool: line 1176: X-MP: command not found ./libtool: line 1176: X-MF: command not found ./libtool: line 1176: Xlibhashkit/.deps/libhashkit_libhashkit_la-aes.Tpo: No such file or directory ./libtool: line 1176: X-c: command not found ./libtool: line 1228: Xlibhashkit/libhashkit_libhashkit_la-aes.lo: No such file or directory ./libtool: line 1233: libtool: compile: cannot determine name of library object from `': command not found make[1]: *** [libhashkit/libhashkit_libhashkit_la-aes.lo] Error 1 make[1]: Leaving directory `/libmemcached' make: *** [all] Error 2 OUTPUT OF ./configure checking build system type... x86_64-unknown-linux-gnu checking host system type... x86_64-unknown-linux-gnu checking target system type... x86_64-unknown-linux-gnu checking for a BSD-compatible install... /usr/bin/install -c checking whether build environment is sane... yes checking for gawk... gawk checking whether make sets $(MAKE)... yes checking for style of include used by make... GNU checking for gcc... gcc checking whether the C compiler works... yes checking for C compiler default output file name... a.out checking for suffix of executables... checking whether we are cross compiling... no checking for suffix of object files... o checking whether we are using the GNU C compiler... yes checking whether gcc accepts -g... yes checking for gcc option to accept ISO C89... none needed checking dependency style of gcc... gcc3 checking dependency style of gcc... (cached) gcc3 checking how to run the C preprocessor... gcc -E checking for grep that handles long lines and -e... /bin/grep checking for egrep... /bin/grep -E checking for ANSI C header files... yes checking for sys/types.h... yes checking for sys/stat.h... yes checking for stdlib.h... yes checking for string.h... yes checking for memory.h... yes checking for strings.h... yes checking for inttypes.h... yes checking for stdint.h... yes checking for unistd.h... yes checking minix/config.h usability... no checking minix/config.h presence... no checking for minix/config.h... no checking whether it is safe to define __EXTENSIONS__... yes checking for isainfo... no checking for g++... g++ checking whether we are using the GNU C++ compiler... yes checking whether g++ accepts -g... yes checking dependency style of g++... gcc3 checking dependency style of g++... (cached) gcc3 checking whether gcc and cc understand -c and -o together... yes checking how to create a ustar tar archive... gnutar checking whether __SUNPRO_C is declared... no checking whether __ICC is declared... no checking "C Compiler version--yes"... "gcc (GCC) 4.1.2 20080704 (Red Hat 4.1.2-52)" checking "C++ Compiler version"... "g++ (GCC) 4.1.2 20080704 (Red Hat 4.1.2-52)" checking whether time.h and sys/time.h may both be included... yes checking whether struct tm is in sys/time.h or time.h... time.h checking for size_t... yes checking for special C compiler options needed for large files... no checking for _FILE_OFFSET_BITS value needed for large files... no checking for library containing clock_gettime... -lrt checking sys/socket.h usability... yes checking sys/socket.h presence... yes checking for sys/socket.h... yes checking size of off_t... 8 checking size of size_t... 8 checking size of long long... 8 checking if time_t is unsigned... no checking for setsockopt... yes checking for bind... yes checking whether the compiler provides atomic builtins... yes checking assert.h usability... yes checking assert.h presence... yes checking for assert.h... yes checking whether to enable assertions... yes checking whether it is safe to use -fdiagnostics-show-option... yes checking whether it is safe to use -floop-parallelize-all... no checking whether it is safe to use -Wextra... yes checking whether it is safe to use -Wformat... yes checking whether it is safe to use -Wconversion... no checking whether it is safe to use -Wmissing-declarations from C++... no checking whether it is safe to use -Wframe-larger-than... no checking whether it is safe to use -Wlogical-op... no checking whether it is safe to use -Wredundant-decls from C++... yes checking whether it is safe to use -Wattributes from C++... no checking whether it is safe to use -Wno-attributes... no checking for perl... perl checking for dpkg-gensymbols... no checking for lcov... no checking for genhtml... no checking for sphinx-build... no checking for working -pipe... yes checking for bison... bison checking for flex... flex checking how to print strings... printf checking for a sed that does not truncate output... /bin/sed checking for fgrep... /bin/grep -F checking for ld used by gcc... /usr/bin/ld checking if the linker (/usr/bin/ld) is GNU ld... yes checking for BSD- or MS-compatible name lister (nm)... /usr/bin/nm -B checking the name lister (/usr/bin/nm -B) interface... BSD nm checking whether ln -s works... yes checking the maximum length of command line arguments... 98304 checking whether the shell understands some XSI constructs... yes checking whether the shell understands "+="... yes checking how to convert x86_64-unknown-linux-gnu file names to x86_64-unknown-linux-gnu format... func_convert_file_noop checking how to convert x86_64-unknown-linux-gnu file names to toolchain format... func_convert_file_noop checking for /usr/bin/ld option to reload object files... -r checking for objdump... objdump checking how to recognize dependent libraries... pass_all checking for dlltool... no checking how to associate runtime and link libraries... printf %s\n checking for ar... ar checking for archiver @FILE support... @ checking for strip... strip checking for ranlib... ranlib checking command to parse /usr/bin/nm -B output from gcc object... ok checking for sysroot... no checking for mt... no checking if : is a manifest tool... no checking for dlfcn.h... yes checking for objdir... .libs checking if gcc supports -fno-rtti -fno-exceptions... no checking for gcc option to produce PIC... -fPIC -DPIC checking if gcc PIC flag -fPIC -DPIC works... yes checking if gcc static flag -static works... yes checking if gcc supports -c -o file.o... yes checking if gcc supports -c -o file.o... (cached) yes checking whether the gcc linker (/usr/bin/ld -m elf_x86_64) supports shared libraries... yes checking whether -lc should be explicitly linked in... no checking dynamic linker characteristics... GNU/Linux ld.so checking how to hardcode library paths into programs... immediate checking whether stripping libraries is possible... yes checking if libtool supports shared libraries... yes checking whether to build shared libraries... yes checking whether to build static libraries... yes checking how to run the C++ preprocessor... g++ -E checking for ld used by g++... /usr/bin/ld -m elf_x86_64 checking if the linker (/usr/bin/ld -m elf_x86_64) is GNU ld... yes checking whether the g++ linker (/usr/bin/ld -m elf_x86_64) supports shared libraries... yes checking for g++ option to produce PIC... -fPIC -DPIC checking if g++ PIC flag -fPIC -DPIC works... yes checking if g++ static flag -static works... yes checking if g++ supports -c -o file.o... yes checking if g++ supports -c -o file.o... (cached) yes checking whether the g++ linker (/usr/bin/ld -m elf_x86_64) supports shared libraries... yes checking dynamic linker characteristics... (cached) GNU/Linux ld.so checking how to hardcode library paths into programs... immediate checking whether the -Werror option is usable... yes checking for simple visibility declarations... yes checking for ISO C++ 98 include files... checking whether memcached executable path has been provided... no checking for memcached... /usr/local/bin/memcached checking whether memcached_sasl executable path has been provided... no checking for memcached_sasl... no checking whether gearmand executable path has been provided... no checking for gearmand... no checking libgearman/gearmand.h usability... no checking libgearman/gearmand.h presence... no checking for libgearman/gearmand.h... no checking for library containing getopt_long... none required checking for library containing gethostbyname... none required checking for the pthreads library -lpthreads... no checking whether pthreads work without any flags... yes checking for joinable pthread attribute... PTHREAD_CREATE_JOINABLE checking if more special flags are required for pthreads... no checking for PTHREAD_PRIO_INHERIT... yes checking the location of cstdint... configure: WARNING: Could not find a cstdint header. <stdint.h> checking the location of cinttypes... configure: WARNING: Could not find a cinttypes header. <inttypes.h> checking whether byte ordering is bigendian... no checking for htonll... no checking for working SO_SNDTIMEO... yes checking for working SO_RCVTIMEO... yes checking for supported struct padding... yes checking for alarm... yes checking for dup2... yes checking for getline... yes checking for gettimeofday... yes checking for memchr... yes checking for memmove... yes checking for memset... yes checking for pipe2... no checking for select... yes checking for setenv... yes checking for socket... yes checking for sqrt... yes checking for strcasecmp... yes checking for strchr... yes checking for strdup... yes checking for strerror... yes checking for strtol... yes checking for strtoul... yes checking for strtoull... yes checking arpa/inet.h usability... yes checking arpa/inet.h presence... yes checking for arpa/inet.h... yes checking fcntl.h usability... yes checking fcntl.h presence... yes checking for fcntl.h... yes checking libintl.h usability... yes checking libintl.h presence... yes checking for libintl.h... yes checking limits.h usability... yes checking limits.h presence... yes checking for limits.h... yes checking malloc.h usability... yes checking malloc.h presence... yes checking for malloc.h... yes checking netdb.h usability... yes checking netdb.h presence... yes checking for netdb.h... yes checking netinet/in.h usability... yes checking netinet/in.h presence... yes checking for netinet/in.h... yes checking stddef.h usability... yes checking stddef.h presence... yes checking for stddef.h... yes checking sys/time.h usability... yes checking sys/time.h presence... yes checking for sys/time.h... yes checking execinfo.h usability... yes checking execinfo.h presence... yes checking for execinfo.h... yes checking cxxabi.h usability... yes checking cxxabi.h presence... yes checking for cxxabi.h... yes checking sys/sysctl.h usability... yes checking sys/sysctl.h presence... yes checking for sys/sysctl.h... yes checking umem.h usability... no checking umem.h presence... no checking for umem.h... no checking for C++ compiler vendor... gnu checking for working alloca.h... yes checking for alloca... yes checking for error_at_line... yes checking for pid_t... yes checking vfork.h usability... no checking vfork.h presence... no checking for vfork.h... no checking for fork... yes checking for vfork... yes checking for working fork... yes checking for working vfork... (cached) yes checking for stdlib.h... (cached) yes checking for GNU libc compatible malloc... yes checking for stdlib.h... (cached) yes checking for GNU libc compatible realloc... yes checking whether strerror_r is declared... yes checking for strerror_r... yes checking whether strerror_r returns char *... yes checking for stdbool.h that conforms to C99... yes checking for _Bool... no checking for int16_t... yes checking for int32_t... yes checking for int64_t... yes checking for int8_t... yes checking for off_t... yes checking for pid_t... (cached) yes checking for ssize_t... yes checking for uint16_t... yes checking for uint32_t... yes checking for uint64_t... yes checking for uint8_t... yes checking whether byte ordering is bigendian... (cached) no checking for an ANSI C-conforming const... yes checking for inline... inline checking for working volatile... yes checking for C/C++ restrict keyword... __restrict checking whether the compiler supports GCC C++ ABI name demangling... yes checking sasl/sasl.h usability... no checking sasl/sasl.h presence... no checking for sasl/sasl.h... no checking uuid/uuid.h usability... yes checking uuid/uuid.h presence... yes checking for uuid/uuid.h... yes checking for main in -luuid... yes checking for clock_gettime in -lrt... yes checking for floor in -lm... yes checking for sigignore... yes checking atomic.h usability... no checking atomic.h presence... no checking for atomic.h... no checking for setppriv... no checking for winsock2.h... no checking for poll.h... yes checking for sys/wait.h... yes checking for fnmatch.h... yes checking for MSG_NOSIGNAL... yes checking for MSG_DONTWAIT... yes checking for MSG_MORE... yes checking event.h usability... yes checking event.h presence... yes checking for event.h... yes checking for main in -levent... yes checking for endianness... little configure: creating ./config.status config.status: creating Makefile config.status: creating docs/conf.py config.status: creating libhashkit-1.0/configure.h config.status: creating libmemcached-1.0/configure.h config.status: creating libmemcached-1.2/configure.h config.status: creating libmemcached-2.0/configure.h config.status: creating support/libmemcached.pc config.status: creating support/libmemcached.spec config.status: creating support/libmemcached-fc.spec config.status: creating libtest/version.h config.status: creating config.h config.status: config.h is unchanged config.status: executing depfiles commands config.status: executing libtool commands --- Configuration summary for libmemcached version 1.0.6 * Installation prefix: /usr/local * System type: unknown-linux-gnu * Host CPU: x86_64 * C Compiler: gcc (GCC) 4.1.2 20080704 (Red Hat 4.1.2-52) * Assertions enabled: yes * Debug enabled: no * Warnings as failure: no * SASL support: --- anyone knows how to solve this ?

    Read the article

  • Using Diskpart in a PowerShell script won't allow script to reuse drive letter

    - by Kyle
    I built a script that mounts (attach) a VHD using Diskpart, cleans out some system files and then unmounts (detach) it. It uses a foreach loop and is suppose to clean multiple VHD using the same drive letter. However, after the 1st VHD it fails. I also noticed that when I try to manually attach a VHD with diskpart, diskpart succeeds, the Disk Manager shows the disk with the correct drive letter, but within the same PoSH instance I can not connect (set-location) to that drive. If I do a manual diskpart when I 1st open PoSH I can attach and detach all I want and I get the drive letter every time. Is there something I need to do to reset diskpart in the script? Here's a snippet of the script I'm using. function Mount-VHD { [CmdletBinding()] param ( [Parameter(Position=0,Mandatory=$true,ValueFromPipeline=$false)] [string]$Path, [Parameter(Position=1,Mandatory=$false,ValueFromPipeline=$false)] [string]$DL, [string]$DiskpartScript = "$env:SystemDrive\DiskpartScript.txt", [switch]$Rescan ) begin { function InvokeDiskpart { Diskpart.exe /s $DiskpartScript } ## Validate Operating System Version ## if (Get-WmiObject win32_OperatingSystem -Filter "Version < '6.1'") {throw "The script operation requires at least Windows 7 or Windows Server 2008 R2."} } process{ ## Diskpart Script Content ## Here-String statement purposefully not indented ## @" $(if ($Rescan) {'Rescan'}) Select VDisk File="$Path" `nAttach VDisk Exit "@ | Out-File -FilePath $DiskpartScript -Encoding ASCII -Force InvokeDiskpart Start-Sleep -Seconds 3 @" Select VDisk File="$Path"`nSelect partition 1 `nAssign Letter="$DL" Exit "@ | Out-File -FilePath $DiskpartScript -Encoding ASCII -Force InvokeDiskpart } end { Remove-Item -Path $DiskpartScript -Force ; "" Write-Host "The VHD ""$Path"" has been successfully mounted." ; "" } } function Dismount-VHD { [CmdletBinding()] param ( [Parameter(Position=0,Mandatory=$true,ValueFromPipeline=$false)] [string]$Path, [switch]$Remove, [switch]$NoConfirm, [string]$DiskpartScript = "$env:SystemDrive\DiskpartScript.txt", [switch]$Rescan ) begin { function InvokeDiskpart { Diskpart.exe /s $DiskpartScript } function RemoveVHD { switch ($NoConfirm) { $false { ## Prompt for confirmation to delete the VHD file ## "" ; Write-Warning "Are you sure you want to delete the file ""$Path""?" $Prompt = Read-Host "Type ""YES"" to continue or anything else to break" if ($Prompt -ceq 'YES') { Remove-Item -Path $Path -Force "" ; Write-Host "VHD ""$Path"" deleted!" ; "" } else { "" ; Write-Host "Script terminated without deleting the VHD file." ; "" } } $true { ## Confirmation prompt suppressed ## Remove-Item -Path $Path -Force "" ; Write-Host "VHD ""$Path"" deleted!" ; "" } } } ## Validate Operating System Version ## if (Get-WmiObject win32_OperatingSystem -Filter "Version < '6.1'") {throw "The script operation requires at least Windows 7 or Windows Server 2008 R2."} } process{ ## DiskPart Script Content ## Here-String statement purposefully not indented ## @" $(if ($Rescan) {'Rescan'}) Select VDisk File="$Path"`nDetach VDisk Exit "@ | Out-File -FilePath $DiskpartScript -Encoding ASCII -Force InvokeDiskpart Start-Sleep -Seconds 10 } end { if ($Remove) {RemoveVHD} Remove-Item -Path $DiskpartScript -Force ; "" } }

    Read the article

  • Ububtu server 12.04 auto installation freezes at kickseeding running if ks.cfg has post scripts

    - by john206
    I'm trying to make a custom Ubuntu Server iso file. Kickstart file (ks.cfg) runs smooth when there is no %post in the file and Ubuntu installs correctly with ks configuration. Installation finishes installing base, apt, grub and It echos: Kickseed Running... and it freezes @ 0% I thought may be apt-get update doesnt work in ks file, I tried to install other apps like apache2 but no luck I have created dozen iso images and installed them in Virtual Box.I have been googling for 3 days and checked out ubuntu forums but haven't figured out the issue. I appreciate your help. This is how I made the iso image. My ks.file and txt.cfg files located in isolinux directory: root@ubuntu:/home/work mount -o loop ubuntu-12.04-amd64.iso original-iso/ rsync -a original-iso/ custom-iso/ cp ks.cfg custom-iso/isolinux/ cp txt.cfg custom-iso/isolinux/ chmod -R 777 custom-iso/ #Creating Iso image mkisofs -D -r -V “$IMAGE_NAME” -cache-inodes -J -l -b isolinux/isolinux.bin -c isolinux/boot.cat -no-emul-boot -boot-load-size 4 -boot-info-table -o ~/ubuntu-12.04-alternate-custom-amd64.iso custom-iso/ ks.cfg #Generated by Kickstart Configurator #platform=AMD64 or Intel EM64T #System language lang en_US #Language modules to install langsupport en_US #System keyboard keyboard us #System mouse mouse #System timezone timezone America/Los_Angeles #Root password rootpw --iscrypted somethingsomething #Initial user user ubuntu --fullname "ubuntu" --iscrypted --password somethingsomething. #Reboot after installation reboot #Use text mode install text #Install OS instead of upgrade install #Use CDROM installation media cdrom #System bootloader configuration bootloader --location=mbr #Clear the Master Boot Record zerombr yes #Partition clearing information clearpart --all --initlabel #Disk partitioning information part /boot --size 128 --fstype=ext3 --asprimary part / --size 512 --fstype=ext3 --asprimary part swap --size 512 part /tmp --size 512 --fstype=ext3 part /var --size 512 --fstype=ext3 part /usr --size 4096 --fstype=ext3 part /home --size 2048 --fstype=ext3 #System authorization infomation auth --useshadow --enablemd5 #Network information network --bootproto=dhcp --device=eth0 #Firewall configuration firewall --disabled --http --ftp --ssh #X Window System configuration information xconfig --depth=32 --resolution=1024x768 --defaultdesktop=GNOME %post apt-get update mkdir /home/user txt.cfg default autoinstall label autoinstall menu label ^Install Custom Ubuntu Server kernel /install/vmlinuz append file=/cdrom/preseed/ubuntu-server.seed initrd=/install/initrd.gz quiet ks=cdrom:/isolinux/ks.cfg -- label install menu label ^Install Ubuntu Server kernel /install/vmlinuz append file=/cdrom/preseed/ubuntu-server.seed vga=788 initrd=/install/initrd.gz quiet -- label cloud menu label ^Multiple server install with MAAS kernel /install/vmlinuz append modules=maas-enlist-udeb vga=788 initrd=/install/initrd.gz quiet -- label check menu label ^Check disc for defects kernel /install/vmlinuz append MENU=/bin/cdrom-checker-menu vga=788 initrd=/install/initrd.gz quiet -- label memtest menu label Test ^memory kernel /install/mt86plus label hd menu label ^Boot from first hard disk localboot 0x80

    Read the article

  • W2k8, Sybase Driver, Permissions

    - by Clustermagnet
    Trying to get a .net (32bit) app running on a Windows 2008 server. My experience in the Windows world is quite limited. Is this related to the Full/Medium trust settings? Have been Googling for quite some time. Appreciate your feedback! Seeing the following error: Required permissions cannot be acquired. Description: An unhandled exception occurred during the execution of the current web request. Please review the stack trace for more information about the error and where it originated in the code. Exception Details: System.Security.Policy.PolicyException: Required permissions cannot be acquired. Source Error: An unhandled exception was generated during the execution of the current web request. Information regarding the origin and location of the exception can be identified using the exception stack trace below. Stack Trace: [PolicyException: Required permissions cannot be acquired.] System.Security.SecurityManager.ResolvePolicy(Evidence evidence, PermissionSet reqdPset, PermissionSet optPset, PermissionSet denyPset, PermissionSet& denied, Boolean checkExecutionPermission) +7606467 System.Security.SecurityManager.ResolvePolicy(Evidence evidence, PermissionSet reqdPset, PermissionSet optPset, PermissionSet denyPset, PermissionSet& denied, Int32& securitySpecialFlags, Boolean checkExecutionPermission) +57 [FileLoadException: Could not load file or assembly 'Sybase.Data.AseClient, Version=1.155.1000.0, Culture=neutral, PublicKeyToken=26e0f1529304f4a7' or one of its dependencies. Failed to grant minimum permission requests. (Exception from HRESULT: 0x80131417)] System.Reflection.Assembly._nLoad(AssemblyName fileName, String codeBase, Evidence assemblySecurity, Assembly locationHint, StackCrawlMark& stackMark, Boolean throwOnFileNotFound, Boolean forIntrospection) +0 System.Reflection.Assembly.nLoad(AssemblyName fileName, String codeBase, Evidence assemblySecurity, Assembly locationHint, StackCrawlMark& stackMark, Boolean throwOnFileNotFound, Boolean forIntrospection) +43 System.Reflection.Assembly.InternalLoad(AssemblyName assemblyRef, Evidence assemblySecurity, StackCrawlMark& stackMark, Boolean forIntrospection) +127 System.Reflection.Assembly.InternalLoad(String assemblyString, Evidence assemblySecurity, StackCrawlMark& stackMark, Boolean forIntrospection) +142 System.Reflection.Assembly.Load(String assemblyString) +28 System.Web.Configuration.CompilationSection.LoadAssemblyHelper(String assemblyName, Boolean starDirective) +46 [ConfigurationErrorsException: Could not load file or assembly 'Sybase.Data.AseClient, Version=1.155.1000.0, Culture=neutral, PublicKeyToken=26e0f1529304f4a7' or one of its dependencies. Failed to grant minimum permission requests. (Exception from HRESULT: 0x80131417)] System.Web.Configuration.CompilationSection.LoadAssemblyHelper(String assemblyName, Boolean starDirective) +613 System.Web.Configuration.CompilationSection.LoadAllAssembliesFromAppDomainBinDirectory() +203 System.Web.Configuration.CompilationSection.LoadAssembly(AssemblyInfo ai) +105 System.Web.Compilation.BuildManager.GetReferencedAssemblies(CompilationSection compConfig) +178 System.Web.Compilation.WebDirectoryBatchCompiler..ctor(VirtualDirectory vdir) +163 System.Web.Compilation.BuildManager.BatchCompileWebDirectoryInternal(VirtualDirectory vdir, Boolean ignoreErrors) +53 System.Web.Compilation.BuildManager.BatchCompileWebDirectory(VirtualDirectory vdir, VirtualPath virtualDir, Boolean ignoreErrors) +175 System.Web.Compilation.BuildManager.CompileWebFile(VirtualPath virtualPath) +86 System.Web.Compilation.BuildManager.GetVPathBuildResultInternal(VirtualPath virtualPath, Boolean noBuild, Boolean allowCrossApp, Boolean allowBuildInPrecompile) +261 System.Web.Compilation.BuildManager.GetVPathBuildResultWithNoAssert(HttpContext context, VirtualPath virtualPath, Boolean noBuild, Boolean allowCrossApp, Boolean allowBuildInPrecompile) +101 System.Web.Compilation.BuildManager.GetVirtualPathObjectFactory(VirtualPath virtualPath, HttpContext context, Boolean allowCrossApp, Boolean noAssert) +126 System.Web.Compilation.BuildManager.CreateInstanceFromVirtualPath(VirtualPath virtualPath, Type requiredBaseType, HttpContext context, Boolean allowCrossApp, Boolean noAssert) +62 System.Web.UI.PageHandlerFactory.GetHandlerHelper(HttpContext context, String requestType, VirtualPath virtualPath, String physicalPath) +33 System.Web.UI.PageHandlerFactory.GetHandler(HttpContext context, String requestType, String virtualPath, String path) +37 System.Web.MaterializeHandlerExecutionStep.System.Web.HttpApplication.IExecutionStep.Execute() +307 System.Web.HttpApplication.ExecuteStep(IExecutionStep step, Boolean& completedSynchronously) +155 Version Information: Microsoft .NET Framework Version:2.0.50727.4959; ASP.NET Version:2.0.50727.4955

    Read the article

  • Unable to start SQL Server Instance 2008 R2 - DB file corrupt

    - by Velu
    I was not able to start the SQL Server 2008 R2 production DB instance. After reading the log file error message is " The log scan number passed to log scan in database ‘master’ is not valid. This error may indicate data corruption or that the log file (.ldf) does not match the data file (.mdf). If this error occurred during replication, re-create the publication." After reading several post i realize that my MASTER DB file is corrupted. I have followed the below setup Copy the Master.mdf and Masterlog.ldf file from Template location to My Database Data folder. C:\Program Files\Microsoft SQL Server\MSSQL10_50.MSSQLSERVER\MSSQL\Binn\Templates to D:\MSSQL\MSSQL10_50.MSSQLSERVER\MSSQL\DATA Note: Same error occur when i copy the all DB file like Master, MasterLog, MSDBData, MSDBlog, Model and ModelLog When i run my MSSQLSEVER instance different problem occur. In My server i had only C, D- Drive i dont have the E drive. How can i override these below error path. Error LOG 2012-10-24 02:51:12.79 spid5s Error: 17204, Severity: 16, State: 1. 2012-10-24 02:51:12.79 spid5s FCB::Open failed: Could not open file e:\sql10_main_t.obj.x86fre\sql\mkmastr\databases\objfre\i386\MSDBData.mdf for file number 1. OS error: 3(The system cannot find the path specified.). 2012-10-24 02:51:12.79 spid5s Error: 5120, Severity: 16, State: 101. 2012-10-24 02:51:12.79 spid5s Unable to open the physical file "e:\sql10_main_t.obj.x86fre\sql\mkmastr\databases\objfre\i386\MSDBData.mdf". Operating system error 3: "3(The system cannot find the path specified.)". 2012-10-24 02:51:12.79 spid5s Error: 17207, Severity: 16, State: 1. 2012-10-24 02:51:12.79 spid5s FileMgr::StartLogFiles: Operating system error 2(The system cannot find the file specified.) occurred while creating or opening file 'e:\sql10_main_t.obj.x86fre\sql\mkmastr\databases\objfre\i386\MSDBLog.ldf'. Diagnose and correct the operating system error, and retry the operation. 2012-10-24 02:51:12.79 spid5s File activation failure. The physical file name "e:\sql10_main_t.obj.x86fre\sql\mkmastr\databases\objfre\i386\MSDBLog.ldf" may be incorrect.

    Read the article

  • All the Gear and No Idea: Suggestions for re-designing my home/office/entertainment network

    - by 5arx
    Help/ Advice/ Suggestions please: I have a load of kit that I love but which currently operate in disconnected, sometimes counter-productive way. Because I never really had a masterplan I just added these things one after another and connected them up in ad hoc ways. Since I bought my Macbook I've found I spend much less time on the MacPro that was until then my main machine. Perversely, as my job involves writing .Net software, I spend a lot of Mac time actually inside a Windows 7 VM. I stream media from the HP box to the PS3 and thus to the TV, but its not without its limitations/annoyances. We listen to each other's iTunes libraries but the music files are all over the place and it would be good to know they were all safely in one location (and fully backed up). I need to come up with a strategy that will allow me to use all the kit for work, play (recording live music, making tunes, iMovie work), pushing/streaming media to the TV and sharing files with my other half (she uses a Windows laptop and her iPod touch). Ideally I'd like to be able to work on any of the machines and have a shared homedrive that was visible to all machines so all my current files were synced up wherever i was. It would be great if I could access everything securely and quickly over the web. I'd also like to be able to set up a background backup process. The kit list thus far: Apple MacPro 8GB/3x250GB RAID0 + 1TB Apple MacBook Pro 13" 8GB/250GB - I spend a lot of my work time on a Windows 7 VM on this. Crappy Acer laptop (for children's use - iPlayer, watching movies/tv files) HP Proliant Server 4GB/80GB+160GB+300GB Sun Ultra 10 2 x 80GB (old, but in top-notch condition) PS3 160GB iPod Classic 2 x 8GB iPod Touch Observations: Part of the problem is our dual use of Windows and OS X - we can't go for a pure NT style roaming profile. Because the server is also used for hosting test/beta applications and a SQL Server db, it can't be dedicated to file serving. The two Macs really could do with sharing a roaming profile or similar. I'd love to be able to do something useful with the Ultra 10. My other half has been trying to throw it away for over five years now and regularly ask what function it serves in my study :-( I've got no shortage of 500GB external USB hard drives iMovie files are very large and ideally would be processed on a RAID system. Apple's TimeMachine isn't so great. If anyone could suggest all or part of a setup that would fulfil some of my requirements I'd be very grateful. I am willing to consider purchasing one or two more bits of kit (an Apple TV and a Squeezebox have been moted by friends) if they will help make efficiencies rather than add to the chaos and confusion. Thanks for looking.

    Read the article

  • Using a 64bit Linux kernel, can't see more than 4GB of RAM in /proc/meminfo

    - by Chris Huang-Leaver
    I'm running my new computer which has 8GB of RAM installed, which is visable from BIOS page, does not show in /proc/meminfo uname -a Linux localhost 3.0.6-gentoo #2 SMP PREEMPT Sat Nov 19 10:45:22 GMT-- x86_64 AMD Phenom(tm) II X4 955 Processor AuthenticAMD GNU/Linux The result of /proc/meminfo is as follows: (thans Andrey) MemTotal: 4021348 kB MemFree: 1440280 kB Buffers: 23696 kB Cached: 1710828 kB SwapCached: 4956 kB Active: 1389904 kB Inactive: 841364 kB Active(anon): 1337812 kB Inactive(anon): 714060 kB Active(file): 52092 kB Inactive(file): 127304 kB Unevictable: 32 kB Mlocked: 32 kB SwapTotal: 8388604 kB SwapFree: 8047900 kB Dirty: 0 kB Writeback: 0 kB AnonPages: 492732 kB Mapped: 47528 kB Shmem: 1555120 kB Slab: 267724 kB SReclaimable: 177464 kB SUnreclaim: 90260 kB KernelStack: 1176 kB PageTables: 12148 kB NFS_Unstable: 0 kB Bounce: 0 kB WritebackTmp: 0 kB CommitLimit: 10399276 kB Committed_AS: 3293896 kB VmallocTotal: 34359738367 kB VmallocUsed: 317008 kB VmallocChunk: 34359398908 kB AnonHugePages: 120832 kB HugePages_Total: 0 HugePages_Free: 0 HugePages_Rsvd: 0 HugePages_Surp: 0 Hugepagesize: 2048 kB DirectMap4k: 23552 kB DirectMap2M: 3088384 kB DirectMap1G: 1048576 kB I have tried using mem=8G as a kernel boot parameter, I read a post about setting HIGHMEM64G to yes, before realising that only applies to 32bit kernels. Trying dmindecode -t memory SMBIOS 2.7 present. Handle 0x0026, DMI type 16, 23 bytes Physical Memory Array Location: System Board Or Motherboard Use: System Memory Error Correction Type: Multi-bit ECC Maximum Capacity: 32 GB Error Information Handle: Not Provided Number Of Devices: 4 Handle 0x0028, DMI type 17, 34 bytes Memory Device Array Handle: 0x0026 Error Information Handle: Not Provided Total Width: 64 bits Data Width: 64 bits Size: 4096 MB Form Factor: DIMM Set: None Locator: DIMM0 Bank Locator: BANK0 Type: <OUT OF SPEC> Type Detail: Synchronous Speed: 1333 MHz Manufacturer: Manufacturer0 Serial Number: SerNum0 Asset Tag: AssetTagNum0 Part Number: Array1_PartNumber0 Rank: Unknown Handle 0x002A, DMI type 17, 34 bytes Memory Device Array Handle: 0x0026 Error Information Handle: Not Provided Total Width: Unknown Data Width: 64 bits Size: No Module Installed Form Factor: DIMM Set: None Locator: DIMM1 Bank Locator: BANK1 Type: Unknown Type Detail: Synchronous Speed: Unknown Manufacturer: Manufacturer1 Serial Number: SerNum1 Asset Tag: AssetTagNum1 Part Number: Array1_PartNumber1 Rank: Unknown Handle 0x002C, DMI type 17, 34 bytes Memory Device Array Handle: 0x0026 Error Information Handle: Not Provided Total Width: 64 bits Data Width: 64 bits Size: 4096 MB Form Factor: DIMM Set: None Locator: DIMM2 Bank Locator: BANK2 Type: <OUT OF SPEC> Type Detail: Synchronous Speed: 1333 MHz Manufacturer: Manufacturer2 Serial Number: SerNum2 Asset Tag: AssetTagNum2 Part Number: Array1_PartNumber2 Rank: Unknown Handle 0x002E, DMI type 17, 34 bytes Memory Device Array Handle: 0x0026 Error Information Handle: Not Provided Total Width: Unknown Data Width: 64 bits Size: No Module Installed Form Factor: DIMM Set: None Locator: DIMM3 Bank Locator: BANK3 Type: Unknown Type Detail: Synchronous Speed: Unknown Manufacturer: Manufacturer3 Serial Number: SerNum3 Asset Tag: AssetTagNum3 Part Number: Array1_PartNumber3 Rank: Unknown

    Read the article

  • What is a good layout for a somewhat advanced home network and storage solution?

    - by Shaun
    My home network/storage needs are changing and I am searching for some opinions and starting points on what a good network/storage layout would be that can serve my needs for a few years into the future. I think I have a decent starting point for equipment, but I am also willing to invest fairly heavily in a solution that can last me for a while. I am a bit of a tech nerd and I have a moderate tolerance for setup of the solution. I would prefer if maintenance of the system is somewhat low once it is setup, but I am willing to accept some tradeoffs. Existing equipment: Router - Netgear WNDR3700 (gigabit) Router - DLink Gamerlounge DGL-4300 (gigabit) Switch - 16 port Trendnet green switch (gigabit) Switch - 5 port Trendnet green (gigabit) Computer - i7-950 office computer (gigabit ethernet) Computer - Q6600 quad core media center, hooked up to TV, records shows (gigabit ethernet) Computer - Acer 1810T ultraportable laptop (gigabit and N ethernet) NAS - Intel SS4200-E (gigabit) External hard drive - 2TB WD Green drive (esata) All kinds of miscellaneous network connected TV, Bluray, Verizon network extender, HDhomerun TV tuners, etc. Requirements: -Robust backup solution for a growing collection of huge family picture files and personal files, around 1.5TB. (Including offsite backup) -Central location for all user's files, while also keeping them secure from each other. -Storage for terabytes of movie backups and recorded TV, and access to them from all computers (maybe around 4TB eventually) -Possibility to host files to friends and family easily Nice to have: -Backup of terabytes of movie backups Intriguing possibilities: -Capability to have users' Windows desktops and files look the same from all network computers I am not sure if the new Windows Home Server 2011 would fit into this well, if I need a domain server, how best to organize my backups, or how to most effectively use RAID. Currently I am simply backing up all computers to a RAID 1 on the NAS box, which I was thinking could prevent a situation where I reach for a backup and find that the disk is corrupt. One possibility that I am thinking about now is simply using my media center PC with a huge RAID of hard drives on which all files are stored. Pseudo-backup of all files would be present because of the RAID, but important files would also be backed up off site via carrying hard drives to work. But what if corruption seeps into the files and the corrupted data is then backed up? Does RAID protect against this? I really want to take next to zero risks with the irreplaceable files. I can handle some degree of risk with the movies and other files. I'm looking for critiques on this idea as well as other possibilities. To summarize, my goal is high functionality, media capable, and robust backup of irreplaceable files.

    Read the article

  • Nginx and PHP-FPM running out of connections

    - by E3pO
    I keep running into errors like these, [02-Jun-2012 01:52:04] WARNING: [pool www] seems busy (you may need to increase pm.start_servers, or pm.min/max_spare_servers), spawning 8 children, there are 19 idle, and 49 total children [02-Jun-2012 01:52:05] WARNING: [pool www] seems busy (you may need to increase pm.start_servers, or pm.min/max_spare_servers), spawning 16 children, there are 19 idle, and 50 total children [02-Jun-2012 01:52:06] WARNING: [pool www] seems busy (you may need to increase pm.start_servers, or pm.min/max_spare_servers), spawning 32 children, there are 19 idle, and 51 total children [02-Jun-2012 03:10:51] WARNING: [pool www] seems busy (you may need to increase pm.start_servers, or pm.min/max_spare_servers), spawning 8 children, there are 18 idle, and 91 total children I changed my settings for php-fpm to these, pm.max_children = 150 (It was at 100, i got a max_children reached and upped to 150) pm.start_servers = 75 pm.min_spare_servers = 20 pm.max_spare_servers = 150 Resulting in [02-Jun-2012 01:39:19] WARNING: [pool www] server reached pm.max_children setting (150), consider raising it I've just launched a new website that is getting a conciderable amount of traffic on it. This traffic is legitimate and users are getting 504 gateway timeouts when the limit is reached. I have limited connections to my server with IPTABLES and I'm running fail2ban and keeping track of nginx access logs. The traffic is all legitimate, i'm just running out of room for users. I'm currently running on a dual core box with ubuntu 64bit. free total used free shared buffers cached Mem: 6114284 5726984 387300 0 141612 4985384 -/+ buffers/cache: 599988 5514296 Swap: 524284 5804 518480 My php.ini max_input_time = 60 My nginx config is worker_processes 4; pid /var/run/nginx.pid; events { worker_connections 19000; # multi_accept on; } worker_rlimit_nofile 20000; #each connection needs a filehandle (or 2 if you are proxying) client_max_body_size 30M; client_body_timeout 10; client_header_timeout 10; keepalive_timeout 5 5; send_timeout 10; location ~ \.php$ { try_files $uri /er/error.php; fastcgi_split_path_info ^(.+\.php)(/.+)$; fastcgi_connect_timeout 60; fastcgi_send_timeout 180; fastcgi_read_timeout 180; fastcgi_buffer_size 128k; fastcgi_buffers 256 16k; fastcgi_busy_buffers_size 256k; fastcgi_temp_file_write_size 256k; fastcgi_max_temp_file_size 0; fastcgi_intercept_errors on; fastcgi_pass unix:/tmp/php5-fpm.sock; fastcgi_index index.php; include fastcgi_params; } What can I do to stop running out of connections? Why does this keep occurring? I'm monitoring my traffic on Google Analytics realtime and when the user count gets above about 120 my php-fpm.log is full of these warnings..

    Read the article

  • Setting up a fileserver, some questions?

    - by Tanax
    Recently I've become very interested in setting up a fileserver, mostly for home usage but also because of the fact that I live in 2 places, I need to be able to access my files from both homes. I have already done some research into this but I am unclear about some things. My requirements are the following; Needs to work on both Mac and PC(only using Windows atm on PC but could be good if it supports more OS's to make it futureproof in case I need Linux or something else) Need to be able to set up a folder/drive/network space to act as a link to a certain folder on the fileserver All files should only be stored on the fileserver, e.g. no "shared" folders like in Dropbox where files are stored on the client computer Would prefer it if folders are password protected or that I can somehow specify what users can access the fileserver's shares Fileserver's OS most likely have to be Windows due to other factors outside of being just a fileserver I've already kinda figured out that I will need to set up a VPN so that I can access my fileserver from outside the local network. Probably going to use OpenVPN. Question 1: How would I go about to set up a VPN server so that I can connect to my local network at the fileserver's location? I know that since I'm on a dynamic IP I will have to get some sort of dynamic DNS server - I've already checked into this and I'm fairly sure I know how to fix that. I also know that I will have to forward the port OpenVPN uses in my router. Question 2: How would I actually share the folders on the fileserver so that I can access them on my other computers? I've researched into Samba but I'm uncertain if it needs to be run on a Linux OS. I know that the clients connecting to it can be Windows for example but can the Samba "server" be run on Windows? Also it appears that Samba shares a folder, meaning it works like Dropbox - I don't want that. So how would I share a folder in that case to make it work like I want it to? Sorry for the incredibly long question, I tried to structure it the best I could for easier read. Thanks in advance!

    Read the article

  • Setting up a fileserver, some questions?

    - by Tanax
    Recently I've become very interested in setting up a fileserver, mostly for home usage but also because of the fact that I live in 2 places, I need to be able to access my files from both homes. I have already done some research into this but I am unclear about some things. My requirements are the following; Needs to work on both Mac and PC(only using Windows atm on PC but could be good if it supports more OS's to make it futureproof in case I need Linux or something else) Need to be able to set up a folder/drive/network space to act as a link to a certain folder on the fileserver All files should only be stored on the fileserver, e.g. no "shared" folders like in Dropbox where files are stored on the client computer Would prefer it if folders are password protected or that I can somehow specify what users can access the fileserver's shares Fileserver's OS most likely have to be Windows due to other factors outside of being just a fileserver I've already kinda figured out that I will need to set up a VPN so that I can access my fileserver from outside the local network. Probably going to use OpenVPN. Question 1: How would I go about to set up a VPN server so that I can connect to my local network at the fileserver's location? I know that since I'm on a dynamic IP I will have to get some sort of dynamic DNS server - I've already checked into this and I'm fairly sure I know how to fix that. I also know that I will have to forward the port OpenVPN uses in my router. Question 2: How would I actually share the folders on the fileserver so that I can access them on my other computers? I've researched into Samba but I'm uncertain if it needs to be run on a Linux OS. I know that the clients connecting to it can be Windows for example but can the Samba "server" be run on Windows? Also it appears that Samba shares a folder, meaning it works like Dropbox - I don't want that. So how would I share a folder in that case to make it work like I want it to? Sorry for the incredibly long question, I tried to structure it the best I could for easier read. Thanks in advance!

    Read the article

  • script to recursively check for and select dependencies

    - by rp.sullivan
    I have written a script that does this but it is one of my first scripts ever so i am sure there is a better way:) Let me know how you would go about doing this. I'm looking for a simple yet efficient way to do this. Here is some important background info: ( It might be a little confusing but hopefully by the end it will make sense. ) 1) This image shows the structure/location of the relevant dirs and files. 2) The packages.file located at ./config/default/config/packages is a space delimited file. field5 is the "package name" which i will call $a for explanations sake. field4 is the name of the dir containing the $a.dir i will call $b field1 shows if the package is selected or not, "X"(capital x) for selected and "O"(capital o as in orange) for not selected. Here is an example of what the packages.file might contain: ... X ---3------ 104.800 database gdbm 1.8.3 / base/library CROSS 0 O -1---5---- 105.000 base libiconv 1.13.1 / base/tool CROSS 0 X 01---5---- 105.000 base pkgconfig 0.25 / base/tool CROSS 0 X -1-3------ 105.000 base texinfo 4.13a / base/tool CROSS DIETLIBC 0 O -----5---- 105.000 develop duma 2_5_15 / base/development CROSS NOPARALLEL 0 O -----5---- 105.000 develop electricfence 2_4_13 / base/development CROSS 0 O -----5---- 105.000 develop gnupth 2.0.7 / extra/development CROSS NOPARALLEL FPIC-QUIRK 0 ... 3) For almost every package listed in the "packages.file" there is a corresponding ".cache file" The .cache file for package $a would be located at ./package/$b/$a/$a.cache The .cache files contain a list of dependencies for that particular package. Here is an example of one of the .cache files might look like. Note that the dependencies are field2 of lines containing "[DEP]" These dependencies are all names of packages in the "package.file" [TIMESTAMP] 1134178701 Sat Dec 10 02:38:21 2005 [BUILDTIME] 295 (9) [SIZE] 11.64 MB, 191 files [DEP] 00-dirtree [DEP] bash [DEP] binutils [DEP] bzip2 [DEP] cf [DEP] coreutils ... So with all that in mind... I'm looking for a shell script that: From within the "main dir" Looks at the ./config/default/config/packages file and finds the "selected" packages and reads the corresponding .cache Then compiles a list of dependencies that excludes the already selected packages Then selects the dependencies (by changing field1 to X) in the ./config/default/config/packages file and repeats until all the dependencies are met Note: The script will ultimately end up in the "scripts dir" and be called from the "main dir". If this is not clear let me know what need clarification. For those interested I'm playing around with T2 SDE. If you are into playing around with linux it might be worth taking a look.

    Read the article

  • Determining the health of a Cisco switch port?

    - by ewwhite
    I've been chasing a packet-loss and network stability issue for a handful of end-users on an internal network for the past few days... These issues surfaced recently, however, the location was struck by lightning six weeks ago. I was seeing 5-10% packet loss between a stack of four Cisco 2960's and several PC's and phones on the other side of a 77-meter run. The PC's were run inline with the phones over a trunked link. We were seeing dropped calls and interruptions in client-server applications and Microsoft Exchange connectivity. I tried the usual troubleshooting steps remotely, having a local technician do the following during breaks in user and production activity: change cables between the wall jack and device. change patch cables between the patch panel and switch port(s). try different switch ports within the 2960 stack. change end-user devices with known-good equipment (new phones, different PC's). clear switch port interface counters and monitor incrementing errors closely. (Pastebin output of sh int) Pored over the device logs and Observium RRD graphs. No link up/down issues from the switch side. change power strips on the end-user side. test cable runs from the Cisco 2960 using test cable-diagnostics tdr int Gi4/0/9 (clean)* test cable runs with a Tripp-Lite cable tester. (clean) run diagnostics on the switch stack members. (clean) In the end, it took three changes of switch ports to find a stable solution. The only logical conclusion is that a few Cisco 2960 switch ports are bad or flaky... Not dead, but not consistent in behavior either. I'm not used to seeing individual ports die in this manner. What else can I test or check to determine if these devices are bad? Is it common for single ports to have problems, rather than a contiguous bank of ports? BTW - show cable-diagnostics tdr int Gi4/0/14 is very cool... Interface Speed Local pair Pair length Remote pair Pair status --------- ----- ---------- ------------------ ----------- -------------------- Gi4/0/14 1000M Pair A 79 +/- 0 meters Pair B Normal Pair B 75 +/- 0 meters Pair A Normal Pair C 77 +/- 0 meters Pair D Normal Pair D 79 +/- 0 meters Pair C Normal

    Read the article

  • Need to increase nginx throughput to an upstream unix socket -- linux kernel tuning?

    - by Ben Lee
    I am running an nginx server that acts as a proxy to an upstream unix socket, like this: upstream app_server { server unix:/tmp/app.sock fail_timeout=0; } server { listen ###.###.###.###; server_name whatever.server; root /web/root; try_files $uri @app; location @app { proxy_set_header X-Forwarded-For $proxy_add_x_forwarded_for; proxy_set_header X-Forwarded-Proto $scheme; proxy_set_header Host $http_host; proxy_redirect off; proxy_pass http://app_server; } } Some app server processes, in turn, pull requests off /tmp/app.sock as they become available. The particular app server in use here is Unicorn, but I don't think that's relevant to this question. The issue is, it just seems that past a certain amount of load, nginx can't get requests through the socket at a fast enough rate. It doesn't matter how many app server processes I set up, it doesn't even matter what the app is (tried it with a dummy app with just a single endpoint that returned an empty page with status 404). The bottleneck seems to be the socket, not the app. I'm getting a flood of these messages in the nginx error log: connect() to unix:/tmp/app.sock failed (11: Resource temporarily unavailable) while connecting to upstream Many requests result in status code 502, and those that don't take a long time to complete. The nginx write queue stat hovers around 1000. Anyway, I feel like I'm missing something obvious here, because this particular configuration of nginx and app server is pretty common, especially with Unicorn (it's the recommended method in fact). Are there any linux kernel options that needs to be set, or something in nginx? Any ideas about how to increase the throughput to the upstream socket? Something that I'm clearly doing wrong? Additional information on the environment: $ uname -a Linux app1 3.2.0-24-generic #39-Ubuntu SMP Mon May 21 16:52:17 UTC 2012 x86_64 x86_64 x86_64 GNU/Linux $ ruby -v ruby 1.9.3p194 (2012-04-20 revision 35410) [x86_64-linux] $ unicorn -v unicorn v4.3.1 $ nginx -V nginx version: nginx/1.2.1 built by gcc 4.6.3 (Ubuntu/Linaro 4.6.3-1ubuntu5) TLS SNI support enabled Current kernel tweaks: net.core.rmem_default = 65536 net.core.wmem_default = 65536 net.core.rmem_max = 16777216 net.core.wmem_max = 16777216 net.ipv4.tcp_rmem = 4096 87380 16777216 net.ipv4.tcp_wmem = 4096 65536 16777216 net.ipv4.tcp_mem = 16777216 16777216 16777216 net.ipv4.tcp_window_scaling = 1 net.ipv4.route.flush = 1 net.ipv4.tcp_no_metrics_save = 1 net.ipv4.tcp_moderate_rcvbuf = 1 net.core.somaxconn = 8192 net.netfilter.nf_conntrack_max = 131072

    Read the article

  • Problem installing Cardbus/PCMCIA drivers (USB 2.0 2-port)

    - by Carl
    I obtained the drivers from the manufacturer for my HT-Link NEC USB 2.0 2-port Cardbus card. When I plugged in the card before I got the drivers, 3 new entries showed up in the Device Manager - two "NEC PCI to USB Open Host Controller" and one "Standard Enhanced PCI to USB Host controller." With the card plugged in, I uninstalled those two drivers. I then removed the card. I copied the new drivers to c:\windows\system32\drivers and the .inf file to c:\windows\inf. I also copied the drivers & inf to a new directory called c:\windows\drivers\ousb2. I reinserted the card. Windows automatically installed the same drivers as before. I selected 'update driver' on the "NEC PCI to USB..." entry and didn't see any other options. I then selected 'have disk' and pointed to c:\windows\drivers\ousb2 and got a message "The specified location does not contain information about your hardware." I then selected 'update driver' on the "Standard Enhanced PCI to USB...," and manually selected "USB 2.0 Enhanced Host Controller" (OWC 4/15/2003 2.1.3.1). Windows then automatically found a USB root hub, and I manually selected "USB 2.0 Root Hub Device" (OWC 4/15/2003 2.1.3.1). Now there are two sections in the Device Manager titled "Universal Serial Bus controllers." I plugged in my external USB hard disk adapter, and "USB Mass Storage Device" was added to the first set. Here's how it looks (w/drivers from the properties): [Universal Serial Bus controllers] Intel(R) 82801DB/DBM USB 2.0 Enhanced Host Controller - 24CD (6/1/2002 5.1.2600.0) Intel(R) 82801DB/DBM USB Universal Host Controller - 24C2 (7/1/2001 5.1.2600.5512) Intel(R) 82801DB/DBM USB Universal Host Controller - 24C4 (7/1/2001 5.1.2600.5512) Intel(R) 82801DB/DBM USB Universal Host Controller - 24C7 (7/1/2001 5.1.2600.5512) NEC PCI to USB Open Host Controller (7/1/2001 5.1.2600.5512) NEC PCI to USB Open Host Controller (7/1/2001 5.1.2600.5512) USB Mass Storage Device USB Root Hub (7/1/2001 5.1.2600.5512) (5 more USB Root Hubs - same driver) [Universal Serial Bus controllers] USB 2.0 Enhanced Host Controller (OWC 4/15/2003 2.1.3.1) USB 2.0 Root Hub Device (OWC 4/15/2003 2.1.3.1) When I unplug the card the two "NEC PCI to USB..." entries in the first set disappear, and the whole second set disappears. (I unplugged the hard disk adapter first...) The hard disk adapter still doesn't work in that Cardbus card with the new drivers. I don't think the above looks right - a second set of USB controllers listed in the Device Manager, and the NEC entries still in the first set, and the the USB mass storage device still in the first set. Any help appreciated. (Windows XP PRO SP3 w/all current updates.)

    Read the article

  • gunicorn + django + nginx unix://socket failed (11: Resource temporarily unavailable)

    - by user1068118
    Running very high volume traffic on these servers configured with django, gunicorn, supervisor and nginx. But a lot of times I tend to see 502 errors. So I checked the nginx logs to see what error and this is what is recorded: [error] 2388#0: *208027 connect() to unix:/tmp/gunicorn-ourapp.socket failed (11: Resource temporarily unavailable) while connecting to upstream Can anyone help debug what might be causing this to happen? This is our nginx configuration: sendfile on; tcp_nopush on; tcp_nodelay off; listen 80 default_server; server_name imp.ourapp.com; access_log /mnt/ebs/nginx-log/ourapp-access.log; error_log /mnt/ebs/nginx-log/ourapp-error.log; charset utf-8; keepalive_timeout 60; client_max_body_size 8m; gzip_types text/plain text/xml text/css application/javascript application/x-javascript application/json; location / { proxy_pass http://unix:/tmp/gunicorn-ourapp.socket; proxy_pass_request_headers on; proxy_read_timeout 600s; proxy_connect_timeout 600s; proxy_redirect http://localhost/ http://imp.ourapp.com/; #proxy_set_header Host $host; #proxy_set_header X-Real-IP $remote_addr; #proxy_set_header X-Forwarded-For $proxy_add_x_forwarded_for; #proxy_set_header X-Forwarded-Proto $my_scheme; #proxy_set_header X-Forwarded-Ssl $my_ssl; } We have configure Django to run in Gunicorn as a generic WSGI application. Supervisord is used to launch the gunicorn workers: home/user/virtenv/bin/python2.7 /home/user/virtenv/bin/gunicorn --config /home/user/shared/etc/gunicorn.conf.py daggr.wsgi:application This is what the gunicorn.conf.py looks like: import multiprocessing bind = 'unix:/tmp/gunicorn-ourapp.socket' workers = multiprocessing.cpu_count() * 3 + 1 timeout = 600 graceful_timeout = 40 Does anyone know where I can start digging to see what might be causing the problem? This is what my ulimit -a output looks like on the server: core file size (blocks, -c) 0 data seg size (kbytes, -d) unlimited scheduling priority (-e) 0 file size (blocks, -f) unlimited pending signals (-i) 59481 max locked memory (kbytes, -l) 64 max memory size (kbytes, -m) unlimited open files (-n) 50000 pipe size (512 bytes, -p) 8 POSIX message queues (bytes, -q) 819200 real-time priority (-r) 0 stack size (kbytes, -s) 8192 cpu time (seconds, -t) unlimited max user processes (-u) 1024 virtual memory (kbytes, -v) unlimited file locks (-x) unlimited

    Read the article

  • Access denied to mysql cause by invalid server hostname bind address

    - by Mark
    I cannot login to mysql using the terminal. [root@fst mysql]# mysql -h localhost -u admin -p Enter password: ERROR 1045 (28000): Access denied for user 'admin'@'localhost' (using password: YES) I am sure I have the correct password. The mysql is also running when I check status. The mysql database is also present in the directory /var/lib/mysql/. The host host.myi, host.myd and host.frm are present. By the way this a related to question on my previous problem MySQL server quit without updating PID file . Initially the problem arise when the root directory was full. To be able to login to directadmin and start mysql, I added a soft link of the /var/lib/mysql/ to /home/mysql. Since my database used up the most of the root directory. The root directory has 50Gb and /home has 1.5Gb. Somehow the /var/lib/mysql/idbdata1 is corrupted. So I move it to another location. Now, I can start the mysql server but I cannot login into it. Below are the contents from the myql logs. 121212 20:44:10 mysqld_safe mysqld from pid file /var/lib/mysql/fst.srv.net.pid ended 121212 20:44:10 mysqld_safe Starting mysqld daemon with databases from /var/lib/mysql 121212 20:44:10 [Note] Plugin 'FEDERATED' is disabled. 121212 20:44:10 InnoDB: The InnoDB memory heap is disabled 121212 20:44:10 InnoDB: Mutexes and rw_locks use GCC atomic builtins 121212 20:44:10 InnoDB: Compressed tables use zlib 1.2.3 121212 20:44:10 InnoDB: Using Linux native AIO 121212 20:44:10 InnoDB: Initializing buffer pool, size = 128.0M 121212 20:44:10 InnoDB: Completed initialization of buffer pool 121212 20:44:10 InnoDB: highest supported file format is Barracuda. 121212 20:44:11 InnoDB: Waiting for the background threads to start 121212 20:44:12 InnoDB: 1.1.8 started; log sequence number 1595675 121212 20:44:12 [Note] Server hostname (bind-address): '0.0.0.0'; port: 3306 121212 20:44:12 [Note] - '0.0.0.0' resolves to '0.0.0.0'; 121212 20:44:12 [Note] Server socket created on IP: '0.0.0.0'. 121212 20:44:12 [Note] Event Scheduler: Loaded 0 events 121212 20:44:12 [Note] /usr/sbin/mysqld: ready for connections. Version: '5.5.27-log' socket: '/var/lib/mysql/mysql.sock' port: 3306 MySQL Community Server (GPL) I guess there is something wrong with the bind address. How should I fix the problem?

    Read the article

  • How to reference a Domain Controller out of the Local Network?

    - by Adrian
    We have multiple servers scattered over different hosting providers. For learning, experimenting and, ultimately, production purposes, I set one of them as a Domain Controller. That went well, most of our services are now authenticating via AD, which helps us a lot. What I want to do now is to simplify the authentication for the multiple servers, by making each of them look at the Domain Controller. This way, our Devs can log into (Remote Desktop) the multiple servers with the same credentials from AD. I know I have to configure each server to look at the Domain Controller. But when I try to add the Domain Controller to the Computer, it cannot find it, although the Domain Controller address is a valid, reachable internet sub-domain (as in "ad.ourcompany.com"). This is the detailed error message: Note: This information is intended for a network administrator. If you are not your network's administrator, notify the administrator that you received this information, which has been recorded in the file C:\Windows\debug\dcdiag.txt. The following error occurred when DNS was queried for the service location (SRV) resource record used to locate an Active Directory Domain Controller for domain ad.ourcompany.com: The error was: "DNS name does not exist." (error code 0x0000232B RCODE_NAME_ERROR) The query was for the SRV record for _ldap._tcp.dc._msdcs.ad.ourcompany.com Common causes of this error include the following: - The DNS SRV records required to locate a AD DC for the domain are not registered in DNS. These records are registered with a DNS server automatically when a AD DC is added to a domain. They are updated by the AD DC at set intervals. This computer is configured to use DNS servers with the following IP addresses: 109.188.207.9 109.188.207.10 - One or more of the following zones do not include delegation to its child zone: ad.ourcompany.com ourcompany.com com . (the root zone) For information about correcting this problem, click Help. What am I missing? I'm an experienced Dev, but a newbie Sysdamin experimenting with new stuff. Disclaimer All IP addresses and domains/subdomains were changed to preserve security. If by any chance you still can see private information, please let me know so that I can change it.

    Read the article

  • backup of KVM VM's running on Ubuntu 12.4.1 precise edition from a remote machine

    - by Dr. Death
    I am creating a library API which will take the backup of all the VM's running on KVM hypervisor. My VM's can be of any type. I am taking this backup from a remote machine and need to put the backup at remote server. I have KVM, Libvirt installed on my system. Some of my VM's are LVM based and some are normal VM's running on KVM. I research and found out an excellent perl script for taking the backup http://pof.eslack.org/2010/12/23/best-solution-to-fully-backup-kvm-virtual-machines/ but since I am developing this library in C++ I cannot use it however it has given me a good understanding of how it will work. One thing I didnot able to sort out is if my VM's are not created using virt-manager or are created using any other tool them virsh system list command does not give them in the list of running VM's however they are running perfectly on my KVM server. Is there a way to list these VM's in my system list anyhow? secondly, when I am taking backup from the remote machine I am getting out of my ssh mode as soon as my libvirt command finishes and for every command I need to ssh again, Is there a way that I do not need to ssh each and every time? I have already used the rsa key for ssh but when once my command finishes my control moves to the remote machine again and try to find out my source VM location in remote machine's local drives which in turn fails it. here is the main problem I am facing. also for the LVM based VM I am able to take the live backup but for non LVM based my machines are getting suspended and not been able to take the live backup. Since my library will work on the remote machine only I might not know the VM's configruation on the KVM server. so need to make it consistent for all the VM's. Please share any thing related to this issue so that I may be able to take the live backup of the non lvm vm's also. I'll update my working and any research findings time to time to all of you. Thanks in advance for your suggestions in these regards.

    Read the article

  • Bladecenter-E Power Module fault

    - by Lihnjo
    We have problem on IBM Bladecenter-E Critical Events Power module 2 is off. DC fault. Power module 4 is off. DC fault. Warnings and System Events Insufficient chassis power to support redundancy What is the best solution for this problem? Thanks AMM Service Data Help SPAPP Capture Available 10/13/2010 17:03:47 1090347 bytes Time: 11/19/2012 11:02:31 UUID: 42E1 5D2F D7BF 41A6 A4A2 48D1 3FB7 0540 MAC Address xx:xx:xx:xx:xx:xx MM Information Name: nnnnn Contact: aaa, bbb, ccc, England Location: [email protected] IP address: 111.222.333.444 Date Time Information GMT offset: +1:00 - Central Europe Time (Western Europe, Algeria, Nigeria, Angola) Adjust for DST: Yes NTP: Enabled NTP Hostname/IP: 111.222.333.444 System Health: Critical System Status Summary One or more monitored parameters are abnormal. Critical Events Power module 2 is off. DC fault. Power module 4 is off. DC fault. Warnings and System Events Insufficient chassis power to support redundancy CHASSIS (BladeCenter-E) in CHASSIS slot: 01 TopoPath is "CHASSIS[1]". Description : BladeCenter-E Width : 1 Sub Type : BladeCenter (BC) Power Mode : 220 v KVM Owner : CHASSIS[1]/BLADE[9] MT Owner : CHASSIS[1]/MGMT_MOD[1] Component Type : CHASSIS Inventory: VPD ID: 336 (decimal) POS ID EXT: 0 (decimal) POS ID: 8 (decimal) Machine Type/Model: 86773RG Machine Serial Number: 99ZL816 Part Number: 39R8561 FRU Number: 39R8563 FRU Serial Number: YK109174W1HV Manufacturer ID: IBM Hardware Revision: 3 (decimal) Manufacture Date: 18 (wk), 07 (yr) UUID: 42E1 5D2F D7BF 41A6 A4A2 48D1 3FB7 0540 (hex) Type Code: 97 (decimal) Sub-type Code: 0 (decimal) IANA Num: 336 (decimal) Product ID: 8 (decimal) Manufacturer Sub ID: FOXC Enviroment data: -------------- Type: : POWER_USAGE Unit: : WATTS Reading: : 0xa Sensor Label: : Midplane Sensor ID: : 0x0 MGMT MOD (Advanced Management Module) in MGMT_MOD slot: 01 TopoPath is "CHASSIS[1]/MGMT_MOD[1]". Description : Advanced Management Module Name : kant Width : 1 Component Role : Primary Component Type : MGMT MOD Insert Time : 28050132 Inventory: VPD ID: 288 (decimal) POS ID EXT: 0 (decimal) POS ID: 4 (decimal) Part Number: 39Y9659 FRU Number: 39Y9661 FRU Serial Number: YK11836CE2RC Manufacturer ID: IBM Hardware Revision: 4 (decimal) Manufacture Date: 50 (wk), 06 (yr) UUID: 1D95 9937 8CA5 11DB 9499 0014 5EDF 1C98 (hex) Type Code: 81 (decimal) Sub-type Code: 1 (decimal) IANA Num: 20301 (decimal) Product ID: 65 (decimal) Manufacturer Sub ID: ASUS Firmware data: Type : AMM firmware Build ID : BPET50P File Name : CNETCMUS.PKT Release Date : 03/26/2010 Release Level : 50 Revision - Major: 80 Port info: ======================================================== Topology Path ID : 1 Label : External Phy Orientation : EXTERNAL Port Number : 1 Type : MGT Physical Meidum : Copper Number of Link Intferfaces : 1 ------------------------------------ Link Ifc ID Number : 1 Link Ifc Transport Protocol : ENET Link Ifc Addr Type : MAC Link Ifc Burned-in Addr : xx:xx:xx:xx:xx:xx Link Ifc Admin Addr : 00:00:00:00:00:00 Link Ifc Addr in use : xx:xx:xx:xx:xx:xx ---------------------------------------------------------- Configuration behaviors: Save Only Enviroment data: -------------- Type: : TEMPERATURE Unit: : DEGREES_C Reading: : 38.00 Sensor Label: : MM Ambient Sensor ID: : 0x0 -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +4.81 Sensor Label: : +5V Sensor ID: : 0x1b -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +3.26 Sensor Label: : +3.3V Sensor ID: : 0x19 -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +11.97 Sensor Label: : +12V Sensor ID: : 0x16 -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : -4.88 Sensor Label: : -5V Sensor ID: : 0x1e -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +2.47 Sensor Label: : +2.5V Sensor ID: : 0x18 -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +1.76 Sensor Label: : +1.8V Sensor ID: : 0x15 -------------- Type: : POWER_USAGE Unit: : WATTS Reading: : 0x19 Sensor Label: : kant Sensor ID: : 0x0

    Read the article

  • URL Rewriting Problem

    - by Eray
    I'm trying to rewrite my URL's subdomain. http://username.domain.com will show content of http://www.domain.com/user.php?u=username but URL stay as http://username.domain.com . (I mean url masking) (Username's can contain a-z 0-9 and hypens) Also if subdomain is www or api, don't redirect them I'm using this for my .htaccess RewriteEngine on RewriteCond %{REQUEST_URI} !^/index\.php$ RewriteCond %{HTTP_HOST} !^www\.domain\.com RewriteCond %{HTTP_HOST} ^([^.]+)\.domain\.com RewriteRule .* /user.php?u=%1 [L] (After @mfarver's advice) I'm trying this RewriteEngine on RewriteRule .* /user.php?u=%1 [L] but this time getting 500 Internal Server error: [Mon May 30 20:10:44 2011] [alert] [client 81.6.xx.xxx] /home/blablabla/public_html/.htaccess: AllowOverride not allowed here (from error log) My server's httpd.conf file's virtualhost settings <VirtualHost 109.73.70.169:80> <IfModule mod_userdir.c> UserDir disabled UserDir enabled USERNAME </IfModule> <IfModule concurrent_php.c> php4_admin_value open_basedir "/home/USERNAME/:/usr/lib/php:/usr/php4/lib/php:/usr/local/lib/php:/usr/local/php4/lib/php:/tmp" php5_admin_value open_basedir "/home/USERNAME/:/usr/lib/php:/usr/local/lib/php:/tmp" </IfModule> <IfModule !concurrent_php.c> <IfModule mod_php4.c> php_admin_value open_basedir "/home/USERNAME/:/usr/lib/php:/usr/php4/lib/php:/usr/local/lib/php:/usr/local/php4/lib/php:/tmp" </IfModule> <IfModule mod_php5.c> php_admin_value open_basedir "/home/USERNAME/:/usr/lib/php:/usr/local/lib/php:/tmp" </IfModule> <IfModule sapi_apache2.c> php_admin_value open_basedir "/home/USERNAME/:/usr/lib/php:/usr/php4/lib/php:/usr/local/lib/php:/usr/local/php4/lib/php:/tmp" </IfModule> </IfModule> ServerName DOMAIN.net ServerAlias *.DOMAIN.net <Directory "/home/USERNAME/public_html"> Options FollowSymLinks Allow from all AllowOverride All </Directory> DocumentRoot /home/USERNAME/public_html ServerAdmin [email protected] UseCanonicalName Off CustomLog /usr/local/apache/domlogs/DOMAIN.net combined CustomLog /usr/local/apache/domlogs/DOMAIN.net-bytes_log "%{%s}t %I .\n%{%s}t %O ." ## User USERNAME # Needed for Cpanel::ApacheConf <IfModule mod_suphp.c> suPHP_UserGroup USERNAME USERNAME </IfModule> <IfModule !mod_disable_suexec.c> SuexecUserGroup USERNAME USERNAME </IfModule> ScriptAlias /cgi-bin/ /home/USERNAME/public_html/cgi-bin/ # To customize this VirtualHost use an include file at the following location # Include "/usr/local/apache/conf/userdata/std/2/USERNAME/DOMAIN.net/*.conf" </VirtualHost> Also *.DOMAIN.net added to my DNS ZONES as A record.

    Read the article

< Previous Page | 381 382 383 384 385 386 387 388 389 390 391 392  | Next Page >