  • How can I set a default sort for tables in PHPMyAdmin (i.e. always "Primary key - Descending")

    - by jeremyclarke
    Even though its obnoxious in a lot of ways I use PHPMyAdmin all the time to debug database issues while writing PHP. By default it sorts tables by primary key ascending. 99% of the time I would rather have the newest data (my test data) shown at the top by default rather than the useless first few records ever saved. Is there a way to configure PHPMyAdmin to show the newest records by default? To alter similar behavior?

    Read the article

  • Do I always need to rebuild the project containing references to sub project's dll, if sub projects

    - by Puneet Dudeja
    I have a solution containing 4 class library projects and one "web site" project. The web site project contains references to the 3 class library projects, whenever I make changes in any of the class library projects, the only option I see is to rebuild the web site which takes a lot of time. Is there any option that I can only update the dll references and the changes are reflected in the web site project ?

    Read the article

  • C++: Why does space always terminate a string when read?

    - by Nullw0rm
    Using type std::string to accept a sentence, for practise (I haven't worked with strings in C++ much) I'm checking if a character is a vowel or not. I got this: for(i = 0; i <= analyse.length(); i++) { if(analyse[i] == 'a' || analyse[i] == 'e' [..etc..]) { ...vowels++; } else { ... ...consenents++; } This works fine if the string is all one word, but the second I add a space (IE: aeio aatest) it will only count the first block and count the space as a consenent, and quit reading the sentence (exiting the for loop or something). Does a space count as no character == null? Or some oddity with std::string?, It would be helpful to know why that is happening!

    Read the article

  • DropDownList always does full-page postback, the first time it fires.

    - by CodexArcanum
    I have an ASP.NET page using the AJAX library. There is a dropdownlist inside an UpdatePanel, which on index changing is supposed to update a different UpdatePanel to modify a grid control. But after the page first comes up, and you adjust the ddl, the entire page postbacks, followed by a (correct) partial postback. After this one time, every other usage of the ddl performs correctly, trigger partial postbacks. Both the panel and the ddl are being added from code. The UP is Conditional updates and ChildrenAsTriggers = true. The dropdownlist is AutoPostBack true and has an event set up on SelectedIndexChanged. So what is going on? I've tried adjusting every setting I can think of and still the page completely refreshes once, then works fine after that.

    Read the article

  • Flash Player, security: If a URL starts with "http://" will the SWF always be loaded into REMOTE san

    - by Pavel
    Seems to be a question for a Flash security guru. Suppose we are loading an external SWF movie with MovieClipLoader.loadMovie(url:String) Is it safe to assume that if url starts with "http://", the movie will be loaded in REMOTE sandbox? We need to tell local SWFs from remote ones to close a security hole. If you need the context read on. We have developed a Projector, written in C++ embedding Flash Player ActiveX. Our Flash application runs inside the Projector. Soon we want to give our users a way to create plugins for the application. The plugins are obviously will be SWF movies. The case I'm afraid of is the following. A bad person creates a malicious evil.swf pretending it to be nice plugin for our app. In case evil.swf is loaded from the local file system it is granted an access to the whole MovieClip tree and Projector API, opening C++ file access operations. On the other hand if evil.swf is loaded from the internet, remotely, it will be locked in REMOTE sandbox by Flash security model. Because of this, we need a reliable way to tell local SWF from remote one before loading it. And we must not make a mistake. So again, is it safe to assume that if url begins with "http://", the clip will be loaded inside REMOTE sandbox?

    Read the article

  • How can I make Google Maps icon to always appear in the center of map - when clicked?

    - by JHM_67
    For simplicity sake, lets use the XML example on Econym's site. http://econym.org.uk/gmap/example_map3.htm Once clicked, I would like icon balloon to be displayed in the middle of the map. What might I need to add to Mike's code to get this to work? I apologize for asking a lot.. Thanks in advance. <script type="text/javascript"> //<![CDATA[ if (GBrowserIsCompatible()) { side_bar var side_bar_html = ""; var gmarkers = []; function createMarker(point,name,html) { var marker = new GMarker(point); GEvent.addListener(marker, "click", function() { marker.openInfoWindowHtml(html); }); gmarkers.push(marker); side_bar_html += '<a href="javascript:myclick(' + (gmarkers.length-1) + ')">' + name + '<\/a><br>'; return marker; } function myclick(i) { GEvent.trigger(gmarkers[i], "click"); } var map = new GMap2(document.getElementById("map")); map.addControl(new GLargeMapControl()); map.addControl(new GMapTypeControl()); map.setCenter(new GLatLng( 43.907787,-79.359741), 9); GDownloadUrl("example.xml", function(doc) { var xmlDoc = GXml.parse(doc); var markers = xmlDoc.documentElement.getElementsByTagName("marker"); for (var i = 0; i < markers.length; i++) { // obtain the attribues of each marker var lat = parseFloat(markers[i].getAttribute("lat")); var lng = parseFloat(markers[i].getAttribute("lng")); var point = new GLatLng(lat,lng); var html = markers[i].getAttribute("html"); var label = markers[i].getAttribute("label"); var marker = createMarker(point,label,html); map.addOverlay(marker); } document.getElementById("side_bar").innerHTML = side_bar_html; }); } else { alert("Sorry, the Google Maps API is not compatible with this browser"); } //]]> </script>

    Read the article

  • Is it always bad idea to use inline css for used-once property?

    - by user93422
    I have a table, with 10 columns. I want to control the width of each column. Each column is unique, right now I create an external CSS style for each column: div#my-page table#members th.name-col { width: 40px; } I know there is a best practice to avoid inline style. I do approve using external CSS for anything look'n'feel related: fonts, colors, images. But is it really better to use external CSS in this case? It does not incur extra maintenance cost. It is easier to produce. Cons I can think of: If you have separate designers and development team - using inline styles will force designers to modify content-file (aspx in my case). It might use more bandwidth. Anything else I've missed?

    Read the article

  • Rails - Always have to check exists, and then value?

    - by Jason B
    I am checking to see if a value in a related table exists quite often in my view, in this case, expenses have approvals. If they have not been submitted, then there is no record of them in the approvals table. I am ending up with some really awkward code <% if !expense_item.expense_approval || expense_item.expense_approval.approval_status == 0 %> Is there a way to do an if statement on a value, without having to check if it exists first? Or some default way to set it nil?

    Read the article

  • Failing Sata HDD

    - by DaveCol
    I think my HDD is fried... Could someone confirm or help me restore it? I was using Hardware RAID 1 Configuration [2 x 160GB SATA HDD] on a CentOS 4 Installation. All of a sudden I started seeing bad sectors on the second HDD which stopped being mirrored. I have removed the RAID array and have tested with SMART which showed the following error: 187 Unknown_Attribute 0x003a 001 001 051 Old_age Always FAILING_NOW 4645 I have no clue what this means, or if I can recover from it. Could someone give me some ideas on how to fix this, or what HDD to get to replace this? Complete SMART report: Smartctl version 5.33 [i686-redhat-linux-gnu] Copyright (C) 2002-4 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: GB0160CAABV Serial Number: 6RX58NAA Firmware Version: HPG1 User Capacity: 160,041,885,696 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 7 ATA Standard is: ATA/ATAPI-7 T13 1532D revision 4a Local Time is: Tue Oct 19 13:42:42 2010 COT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED See vendor-specific Attribute list for marginal Attributes. General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 433) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 54) minutes. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 100 253 006 Pre-fail Always - 0 3 Spin_Up_Time 0x0002 097 097 000 Old_age Always - 0 4 Start_Stop_Count 0x0033 100 100 020 Pre-fail Always - 152 5 Reallocated_Sector_Ct 0x0033 095 095 036 Pre-fail Always - 214 7 Seek_Error_Rate 0x000f 078 060 030 Pre-fail Always - 73109713 9 Power_On_Hours 0x0032 083 083 000 Old_age Always - 15133 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0033 100 100 020 Pre-fail Always - 154 184 Unknown_Attribute 0x0032 038 038 000 Old_age Always - 62 187 Unknown_Attribute 0x003a 001 001 051 Old_age Always FAILING_NOW 4645 189 Unknown_Attribute 0x0022 100 100 000 Old_age Always - 0 190 Unknown_Attribute 0x001a 061 055 000 Old_age Always - 656408615 194 Temperature_Celsius 0x0000 039 045 000 Old_age Offline - 39 (Lifetime Min/Max 0/22) 195 Hardware_ECC_Recovered 0x0032 070 059 000 Old_age Always - 12605265 197 Current_Pending_Sector 0x0000 100 100 000 Old_age Offline - 1 198 Offline_Uncorrectable 0x0000 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0000 200 200 000 Old_age Offline - 62 SMART Error Log Version: 1 ATA Error Count: 4645 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 4645 occurred at disk power-on lifetime: 15132 hours (630 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 7b 86 b1 ea Error: UNC at LBA = 0x0ab1867b = 179406459 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 02 7b 86 b1 ea 00 00:38:52.796 READ DMA ec 03 45 00 00 00 a0 00 00:38:52.796 IDENTIFY DEVICE ef 03 45 00 00 00 a0 00 00:38:52.794 SET FEATURES [Set transfer mode] ec 00 00 7b 86 b1 a0 00 00:38:49.991 IDENTIFY DEVICE c8 00 04 79 86 b1 ea 00 00:38:49.935 READ DMA Error 4644 occurred at disk power-on lifetime: 15132 hours (630 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 7b 86 b1 ea Error: UNC at LBA = 0x0ab1867b = 179406459 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 04 79 86 b1 ea 00 00:38:41.517 READ DMA ec 03 45 00 00 00 a0 00 00:38:41.515 IDENTIFY DEVICE ef 03 45 00 00 00 a0 00 00:38:41.515 SET FEATURES [Set transfer mode] ec 00 00 7b 86 b1 a0 00 00:38:49.991 IDENTIFY DEVICE c8 00 06 77 86 b1 ea 00 00:38:49.935 READ DMA Error 4643 occurred at disk power-on lifetime: 15132 hours (630 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 7b 86 b1 ea Error: UNC at LBA = 0x0ab1867b = 179406459 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 06 77 86 b1 ea 00 00:38:41.517 READ DMA ec 03 45 00 00 00 a0 00 00:38:41.515 IDENTIFY DEVICE ef 03 45 00 00 00 a0 00 00:38:41.515 SET FEATURES [Set transfer mode] ec 00 00 7b 86 b1 a0 00 00:38:41.513 IDENTIFY DEVICE c8 00 06 77 86 b1 ea 00 00:38:38.706 READ DMA Error 4642 occurred at disk power-on lifetime: 15132 hours (630 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 7b 86 b1 ea Error: UNC at LBA = 0x0ab1867b = 179406459 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 06 77 86 b1 ea 00 00:38:41.517 READ DMA ec 03 45 00 00 00 a0 00 00:38:41.515 IDENTIFY DEVICE ef 03 45 00 00 00 a0 00 00:38:41.515 SET FEATURES [Set transfer mode] ec 00 00 7b 86 b1 a0 00 00:38:41.513 IDENTIFY DEVICE c8 00 06 77 86 b1 ea 00 00:38:38.706 READ DMA Error 4641 occurred at disk power-on lifetime: 15132 hours (630 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 7b 86 b1 ea Error: UNC at LBA = 0x0ab1867b = 179406459 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 06 77 86 b1 ea 00 00:38:41.517 READ DMA ec 03 45 00 00 00 a0 00 00:38:41.515 IDENTIFY DEVICE ef 03 45 00 00 00 a0 00 00:38:41.515 SET FEATURES [Set transfer mode] ec 00 00 7b 86 b1 a0 00 00:38:41.513 IDENTIFY DEVICE c8 00 06 77 86 b1 ea 00 00:38:38.706 READ DMA SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 15131 - # 2 Short offline Completed without error 00% 15131 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.

    Read the article

  • Using smartctl to get vendor specific Attributes from ssd drive behind a SmartArray P410 controller

    - by Lairsdragon
    Hi! Recently I have deployed some HP server with SSD's behind a SmartArray P410 controller. While not official supported from HP the server work well sofar. Now I like to get wear level info's, error statistics etc from the drive. While the SA P410 supports a passthru of the SMART Command to a single drive in the array the output I was not able to the the interesting things from the drive. In this case especially the value the Wear level indicator is from interest for me (Attr.ID 233), but this is ony present if the drive is directly attanched to a SATA Controller. smartctl on directly connected ssd: # smartctl -A /dev/sda smartctl version 5.38 [x86_64-unknown-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF READ SMART DATA SECTION === SMART Attributes Data Structure revision number: 5 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 3 Spin_Up_Time 0x0000 100 000 000 Old_age Offline In_the_past 0 4 Start_Stop_Count 0x0000 100 000 000 Old_age Offline In_the_past 0 5 Reallocated_Sector_Ct 0x0002 100 100 000 Old_age Always - 0 9 Power_On_Hours 0x0002 100 100 000 Old_age Always - 8561 12 Power_Cycle_Count 0x0002 100 100 000 Old_age Always - 55 192 Power-Off_Retract_Count 0x0002 100 100 000 Old_age Always - 29 232 Unknown_Attribute 0x0003 100 100 010 Pre-fail Always - 0 233 Unknown_Attribute 0x0002 088 088 000 Old_age Always - 0 225 Load_Cycle_Count 0x0000 198 198 000 Old_age Offline - 508509 226 Load-in_Time 0x0002 255 000 000 Old_age Always In_the_past 0 227 Torq-amp_Count 0x0002 000 000 000 Old_age Always FAILING_NOW 0 228 Power-off_Retract_Count 0x0002 000 000 000 Old_age Always FAILING_NOW 0 smartctl on P410 connected ssd: # ./smartctl -A -d cciss,0 /dev/cciss/c1d0 smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net (Right, it is complety empty) smartctl on P410 connected hdd: # ./smartctl -A -d cciss,0 /dev/cciss/c0d0 smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net Current Drive Temperature: 27 C Drive Trip Temperature: 68 C Vendor (Seagate) cache information Blocks sent to initiator = 1871654030 Blocks received from initiator = 1360012929 Blocks read from cache and sent to initiator = 2178203797 Number of read and write commands whose size <= segment size = 46052239 Number of read and write commands whose size > segment size = 0 Vendor (Seagate/Hitachi) factory information number of hours powered up = 3363.25 number of minutes until next internal SMART test = 12 Do I hunt here a bug, or is this a limitation of the p410 SMART cmd Passthru?

    Read the article

  • VoIP on Netgear DGN 2000 and Lynksys PAP2

    - by David Brown
    I have a VoIP service running perfectly for outgoing calls but I cannot receive incoming calls. I have a Netgear DGN 2000 modem router on 192.168.0.1 and a Lynksys Phone Adapter PAP2 on 192.168.0.2. I have created 3 new custom services: Service Table Service Name Ports tlenfon(TCP) 5060 tlenfon2(UDP) 15000 tlenfon3(UDP) 35000 I have reserved the address 192.168.0.2 for the PAP 2 I have forwarded the ports for each service to the PAP2 Service Name Action LAN Server IP address WAN Users Log tlenfon ALLOW always 192.168.0.2 Any Always tlenfon2 ALLOW always 192.168.0.2 Any Always tlenfon3 ALLOW always 192.168.0.2 Any Always I have checked the Default DMZ and specified 192.168.0.2 What have I missed?

    Read the article

  • NHibernate Session Load vs Get when using Table per Hierarchy. Always use ISession.Get&lt;T&gt; for TPH to work.

    - by Rohit Gupta
    Originally posted on: http://geekswithblogs.net/rgupta/archive/2014/06/01/nhibernate-session-load-vs-get-when-using-table-per-hierarchy.aspxNHibernate ISession has two methods on it : Load and Get. Load allows the entity to be loaded lazily, meaning the actual call to the database is made only when properties on the entity being loaded is first accessed. Additionally, if the entity has already been loaded into NHibernate Cache, then the entity is loaded directly from the cache instead of querying the underlying database. ISession.Get<T> instead makes the call to the database, every time it is invoked. With this background, it is obvious that we would prefer ISession.Load<T> over ISession.Get<T> most of the times for performance reasons to avoid making the expensive call to the database. let us consider the impact of using ISession.Load<T> when we are using the Table per Hierarchy implementation of NHibernate. Thus we have base class/ table Animal, there is a derived class named Snake with the Discriminator column being Type which in this case is “Snake”. If we load This Snake entity using the Repository for Animal, we would have a entity loaded, as shown below: public T GetByKey(object key, bool lazy = false) { if (lazy) return CurrentSession.Load<T>(key); return CurrentSession.Get<T>(key); } var tRepo = new NHibernateReadWriteRepository<TPHAnimal>(); var animal = tRepo.GetByKey(new Guid("602DAB56-D1BD-4ECC-B4BB-1C14BF87F47B"), true); var snake = animal as Snake; snake is null As you can see that the animal entity retrieved from the database cannot be cast to Snake even though the entity is actually a snake. The reason being ISession.Load prevents the entity to be cast to Snake and will throw the following exception: System.InvalidCastException :  Message=Unable to cast object of type 'TPHAnimalProxy' to type 'NHibernateChecker.Model.Snake'. Thus we can see that if we lazy load the entity using ISession.Load<TPHAnimal> then we get a TPHAnimalProxy and not a snake. =============================================================== However if do not lazy load the same cast works perfectly fine, this is since we are loading the entity from database and the entity being loaded is not a proxy. Thus the following code does not throw any exceptions, infact the snake variable is not null: var tRepo = new NHibernateReadWriteRepository<TPHAnimal>(); var animal = tRepo.GetByKey(new Guid("602DAB56-D1BD-4ECC-B4BB-1C14BF87F47B"), false); var snake = animal as Snake; if (snake == null) { var snake22 = (Snake) animal; }

    Read the article

  • My hardware MAC address is always 00:00:00:00:00:00 until I manually update 'eth0'. How can I fix this?

    - by user57184
    I am using Ubuntu 12.04. I use a wired connection. My network MAC address shows as 00:00:00:00:00:00. When I enter the commands below into a terminal window, it starts working again. sudo ifconfig eth0 down sudo ifconfig eth0 hw ether my mac address sudo ifconfig eth0 up I have to enter these commands every time I want to use the Internet. How can I fix this? Update copied from comment The contents of my /etc/NetworkManager/NetworkManager.conf file is: [main] plugins=ifupdown,keyfile dns=dnsmasq no-auto-default=00:00:00:00:00:00, [ifupdown] managed=false

    Read the article

  • Keep a Window on top with a handy AutoHotkey script

    - by Matthew Guay
    Are you tired of shuffling back and forth between windows to get your work done?  Here’s a handy tool that lets you keep any window always on top when you need it. There are many ways to use multiple windows efficiently, but sometimes it seems you need to keep a smaller one in front of a larger window and they never quite fit right.  Whether you’re trying to use Calculator and a web form at the same time, or see what music is playing while you’re catching up on your news, there’s many scenarios where it can be useful to keep one window always on top.  There are many utilities to do this, but they are often needlessly complicated and bloated.  Here we look at a better solution from Amit, our friend at Digital Inspiration. Always on Top Thanks to AutoHotkey, you can easily always keep any window on top of all the others on your screen.  You can download this as a small exe and run it directly, or can create it with a simple script in AutoHotkey.  For simplicity, we simply downloaded the application and ran it directly. To do this, download Always on Top (link below), and unzip the file. Once you’ve launched it, simply select the window you want to keep on top and press Ctrl+Space.  This program will now stay in front, even when it is not the active window.  Here’s a screenshot of a Hotmail signup dialog in Chrome with Notepad kept on top.  Notice Notepad isn’t the active application, but it is still on top. If you wish to un-pin the window from being on top, simply select the window and press Ctrl+space again.  You can keep multiple windows pinned at once, too, though you may clutter your desktop quickly! Always on Top will keep running in your system tray, and you can exit or suspend it by right-clicking on its tray icon and selecting exit or suspend, respectively. Create Your Own Always on Top Utility with AutoHotkey If you’re a fan of AutoHotkey, you can create your own AutoHotkey script to keep windows on top simply and easily with only one line of code: ^SPACE:: Winset, Alwaysontop, , A Simply create a new file, insert the code, and save it as plaintext with the .ahk file extension.  If you have AutoHotkey installed, simply double-click this file for the exact same functionality as the premade version. Conclusion This is a great way to keep a window handy, and it can be beneficial in many scenarios.  For instance you can use it to copy data from a PDF or image into a form or spreadsheet, and it saves a lot of clicks and time.  Links: Download Always on Top from Digital Inspiration Download AutoHotkey if you want to make it yourself Similar Articles Productive Geek Tips Get the Linux Alt+Window Drag Functionality in WindowsGet Mac’s Hide Others (cmd+opt+H) Keyboard Shortcut for WindowsAdd "Run as Administrator" for AutoHotkey Scripts in Windows 7 or VistaKeyboard Ninja: Pop Up the Vista Calendar with a Single HotkeyKeyboard Ninja: Assign a Hotkey to any Window TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips Revo Uninstaller Pro Registry Mechanic 9 for Windows PC Tools Internet Security Suite 2010 PCmover Professional OutSync will Sync Photos of your Friends on Facebook and Outlook Windows 7 Easter Theme YoWindoW, a real time weather screensaver Optimize your computer the Microsoft way Stormpulse provides slick, real time weather data Geek Parents – Did you try Parental Controls in Windows 7?

    Read the article

  • How to let MSN or Yahoo Messenger set you to be Invisible or Offline when you are idle for an hour?

    - by Jian Lin
    The short question is: How do we let MSN or Yahoo Messenger set us to be Invisible or Offline when we are idle for half an hour or an hour? The reason is: if I am on 24 hours a day, some people see me as weird. Some people see my value as low, because I am always there. There are ways to set me to "Away" or "Busy" after 10 minutes, but there seems to be no way to set myself to invisible or offline after 1 hour. As I am a software developer, I am very used to turning the computer on 24 hours a day. (for example, for checking email for urgent fixes, and fix issue and push to web server). We don't turn off computer usually even when we sleep, because we may sometimes can't sleep yet and come check on the computer, or wake up in the morning and immediately need to check if everything is ok. But, my MSN and Yahoo Messenger is always on for 24 hours a day, and I found that some girls start to ask me why I am always there 24 hours a day (even though they see me as away or busy, their feeling is that I am always there). What's more, I found that since I am always there, my value actually drop in their eyes, because hard to get = high value, and always there = low value. Some people feel me as having nothing much to do, always in front of computer, or what is he doing in front of computer so much? Now since it is my job, and I need to read emails once in a while, I am in fact in front of the computer more than some other people. I am in front of the computer maybe 10 hours a day, far from 24 hours a day. Is there an easy and automatic solution to this?

    Read the article

< Previous Page | 35 36 37 38 39 40 41 42 43 44 45 46  | Next Page >