  • Office 2007 constantly crashes, logged as Event ID 1000

    - by Nori
    I have a user, who despite my best efforts, is having constant Office 2007 crashes. I've tried deleting their profile and setting it up again, repairing office, uninstalling completely and then reinstalling, and swapping out memory sticks. One event log error I keep getting is the following: (note all the Office errors are event id 1000) Faulting application name: OUTLOOK.EXE, version: 12.0.6539.5000, time stamp: 0x4c12486d Faulting module name: EMSMDB32.DLL, version: 12.0.6539.5000, time stamp: 0x4c1246f8 Exception code: 0xc0000005 Fault offset: 0x0005d8e2 Faulting process id: 0xf6c Faulting application start time: 0x01cb6633f33384f3 Faulting application path: C:\Program Files (x86)\Microsoft Office\Office12\OUTLOOK.EXE Faulting module path: c:\progra~2\micros~1\office12\EMSMDB32.DLL Report Id: 0d4a2eab-d231-11df-80a0-4061868f5d10 I also get this: Faulting application name: OUTLOOK.EXE, version: 12.0.6539.5000, time stamp: 0x4c12486d Faulting module name: olmapi32.dll, version: 12.0.6538.5000, time stamp: 0x4bfc6ad9 Exception code: 0xc0000005 Fault offset: 0x002357a9 Faulting process id: 0x5e4 Faulting application start time: 0x01cb661f4546aa77 Faulting application path: C:\Program Files (x86)\Microsoft Office\Office12\OUTLOOK.EXE Faulting module path: c:\progra~2\micros~1\office12\olmapi32.dll Report Id: a4a90658-d224-11df-80a0-4061868f5d10 The Excel error is this: Faulting application name: EXCEL.EXE, version: 12.0.6535.5002, time stamp: 0x4bd2a7f1 Faulting module name: KERNELBASE.dll, version: 6.1.7600.16385, time stamp: 0x4a5bdbdf Exception code: 0xe06d7363 Fault offset: 0x0000b727 Faulting process id: 0x14a8 Faulting application start time: 0x01cb61ab7bc0abab Faulting application path: C:\Program Files (x86)\Microsoft Office\Office12\EXCEL.EXE Faulting module path: C:\Windows\syswow64\KERNELBASE.dll Report Id: ba0c454b-cd9e-11df-80a0-4061868f5d10 Also have gotten this for PowerPoint: Faulting application name: POWERPNT.EXE, version: 12.0.6500.5000, time stamp: 0x49a68f9d Faulting module name: COMShim.dll, version: 2010.3.325.110, time stamp: 0x4c51e0b1 Exception code: 0x40000015 Fault offset: 0x0001e388 Faulting process id: 0x1480 Faulting application start time: 0x01cb5fe9a0660e81 Faulting application path: C:\Program Files (x86)\Microsoft Office\Office12\POWERPNT.EXE Faulting module path: C:\Program Files (x86)\FactSet\COMShim.dll Report Id: e03d2a21-cbdc-11df-9bc8-4061868f5d10 (Some of the above lines edited to keep you from scroll horizontally.) Lastly, I get this error several times a day, I don't think it is related but maybe it is: Failed extract of third-party root list from auto update cab at: http://www.download.windowsupdate.com/msdownload/update/v3/static/trustedr/en/authrootstl.cab with error: A required certificate is not within its validity period when verifying against the current system clock or the timestamp in the signed file. Any ideas? This is driving me nuts.

    Read the article

  • Deploying Windows Service through group policy fails with Event ID 102

    - by Sören Kuklau
    I'm trying to deploy a custom Windows Service (written in C#; installed through a VS setup project) using a group policy. To help debug this, I also have two additional MSIs in the same policy. All three packages are deployed as a machine policy, not a user one. On one machine (runs Windows Server 2008; no UAC), all three deploy fine. The service is set to Automatic, as expected. On two machines (run Windows 7; UAC), the two other MSIs deploy fine, but my service fails to install. The event log gives an event ID of 102, which appears to be a permissions problem: The install of application "Package Name" from policy "Policy Name" failed. The error was The installation source for this product is not available. Verify that the source exists and that you can access it. However, all three packages come from the same share linked through UNC, so this is unlikely. My guess is that UAC is the problem; that the service requires additional permissions. Do I need to alter the MSI somehow?

    Read the article

  • zsh auto-complete event designator

    - by simont
    (See my previous question for additional context). I'm migrating to zsh from bash, and using oh-my-zsh. When my zsh history looks something like the following: git status git add -A git commit I want to be able to re-run git add -A. To do that, I could use !?git add, which should: !?str[?] Refer to the most recent command containing str. The trailing ‘?’ is necessary if this reference is to be followed by a modifier or followed by any text that is not to be considered part of str. The link for zsh event designators is here. Unfortunately, I can't do this - as I'm typing !?git add, as I hit the ' ', it auto-completes the command to the most recent command matching git (ie, it auto-completes with git commit). I can't use the event designator properly because of this auto-completion as I hit the space. I assume this is an oh-my-zsh feature. I have no idea where to look, though - greping for 'complet' in the oh-my-zsh source doesn't get me anywhere. My question: how do I turn off this feature? Or, if that's not something that's known, where should I be looking - if I was going to implement this auto-complete when whitespace is entered, where would be a logical place to do so in the oh-my-zsh framework?

    Read the article

  • UACCEEventLog 301 Filling Event Logs

    - by rjt
    After pushing out clients for the MS Application Compatibility Toolkit on our domain via GPO, UACCEEventLog 301 occurs a few times per second in the event log. Several Thousand per hour. One test i need to do is logon with Administrator to see if these events go away while Admin, but of course that is not a fix. This is only part of the event log entry, but is the most readable and clearly indicates yet another problem with Antivirus software. But still no fix. Originally, i posted this In Words and Bytes, but then edited it to make it much easier to read. LocalMachine\Users do have Read Access to this key. For a test, i added "Domain Users" but there are many more events for other parts of the registry and for Administrators. <XML> <TYPE> UacceRegistryVirtualization </TYPE> <EXENAME>smcgui.exe</EXENAME> <EXEPATH>c:\program files\symantec\symantec endpoint protection </EXEPATH> <APINAME>RegOpenKeyA</APINAME> <REGKEYNAME> HKEY_LOCAL_MACHINE\SOFTWARE \Symantec\Symantec Endpoint Protection\AV\Storages \SymHeurProcessProtection\RealTimeScan\0 </REGKEYNAME> <RESTRICTEDBYACL>FALSE</RESTRICTEDBYACL> <DESIREDACCESS>MAXIMUM_ALLOWED</DESIREDACCESS> <REGVALUENAME></REGVALUENAME> <REGVALUETYPE>0x00000000</REGVALUETYPE> <REGVALUEDATA></REGVALUEDATA> <CURRENTGROUP>Users</CURRENTGROUP> </XML>

    Read the article

  • Diagnosing Logon Audit Failure event log entries

    - by Scott Mitchell
    I help a client manage a website that is run on a dedicated web server at a hosting company. Recently, we noticed that over the last two weeks there have been tens of thousands of Audit Failure entries in the Security Event Log with Task Category of Logon - these have been coming in about every two seconds, but interesting stopped altogether as of two days ago. In general, the event description looks like the following: An account failed to log on. Subject: Security ID: SYSTEM Account Name: ...The Hosting Account... Account Domain: ...The Domain... Logon ID: 0x3e7 Logon Type: 10 Account For Which Logon Failed: Security ID: NULL SID Account Name: david Account Domain: ...The Domain... Failure Information: Failure Reason: Unknown user name or bad password. Status: 0xc000006d Sub Status: 0xc0000064 Process Information: Caller Process ID: 0x154c Caller Process Name: C:\Windows\System32\winlogon.exe Network Information: Workstation Name: ...The Domain... Source Network Address: 173.231.24.18 Source Port: 1605 The value in the Account Name field differs. Above you see "david" but there are ones with "john", "console", "sys", and even ones like "support83423" and whatnot. The Logon Type field indicates that the logon attempt was a remote interactive attempt via Terminal Services or Remote Desktop. My presumption is that these are some brute force attacks attempting to guess username/password combinations in order to log into our dedicated server. Are these presumptions correct? Are these types of attacks pretty common? Is there a way to help stop these types of attacks? We need to be able to access the desktop via Remote Desktop so simply turning off that service is not feasible. Thanks

    Read the article

  • returning correct multiTouch id

    - by Max
    I've spent countless hours on reading tutorials and looking at every question related to multiTouch from here and Stackoverflow. But I just cannot figure out how to do this correctly. I use a loop to get my pointerId, I dont see alot of people doing this but its the only way I've managed to get it somewhat working. I have two joysticks on my screen, one for moving and one for controlling my sprites rotation and the angle he shoots, like in Monster Shooter. Both these work fine. My problem is that when I Move my sprite at the same time as Im shooting, my touchingPoint for my movement is set to the touchingPoint of my shooting, since the x and y is higher on the touchingPoint of my shooting (moving-stick on left side of screen, shooting-stick on right side), my sprite speeds up, this creates an unwanted change in speed for my sprite. I will post my entire onTouch method here with some variable-changes to make it more understandable. Since I do not know where Im going wrong. public void update(MotionEvent event) { if (event == null && lastEvent == null) { return; } else if (event == null && lastEvent != null) { event = lastEvent; } else { lastEvent = event; } int pointerCount = event.getPointerCount(); for (int i = 0; i < pointerCount; i++) { int x = (int) event.getX(i); int y = (int) event.getY(i); int id = event.getPointerId(i); int action = event.getActionMasked(); int actionIndex = event.getActionIndex(); String actionString; switch (action) { case MotionEvent.ACTION_DOWN: actionString = "DOWN"; break; case MotionEvent.ACTION_UP: shooting=false; // when shooting is true, it shoots dragging=false; // when dragging is true, it moves actionString = "UP"; break; case MotionEvent.ACTION_POINTER_DOWN: actionString = "PNTR DOWN"; break; case MotionEvent.ACTION_POINTER_UP: shooting=false; dragging=false; actionString = "PNTR UP"; break; case MotionEvent.ACTION_CANCEL: shooting=false; dragging=false; actionString = "CANCEL"; break; case MotionEvent.ACTION_MOVE: try{ if((int) event.getX(id) > 0 && (int) event.getX(id) < touchingBox && (int) event.getY(id) > touchingBox && (int) event.getY(id) < view.getHeight()){ movingPoint.x = (int) event.getX(id); movingPoint.y = (int) event.getY(id); dragging = true; } else if((int) event.getX(id) > touchingBox && (int) event.getX(id) < view.getWidth() && (int) event.getY(id) > touchingBox && (int) event.getY(id) < view.getHeight()){ shootingPoint.x = (int) event.getX(id); shootingPoint.y = (int) event.getY(id); shooting=true; }else{ shooting=false; dragging=false; } }catch(Exception e){ } actionString = "MOVE"; break; default: actionString = ""; } Wouldnt post this much code if I wasnt at an absolute loss of what I'm doing wrong. I simply can not get a good understanding of how multiTouching works. basicly movingPoint changes for both my first and second finger. I bind it to a box, but aslong as I hold one finger within this box, it changes its value based on where my second finger touches. It moves in the right direction and nothing gives an error, the problem is the speed-change, its almost like it adds up the two touchingPoints.

    Read the article

  • Norton Ghost EBAB03F1: The specified network name is no longer available.

    - by Breck Carter
    After about 15 minutes, a Norton Ghost 14 backup fails with Error EBAB03F1: The specified network name is no longer available. The source computer is a P4 laptop running Windows XP SP3. The target computer is a Core2 Quad desktop running Windows Vista Ultimate 64bit. It does not help to disable Norton 360 on the source computer or Norton Antivirus 2008 on the target computer. The Event Viewer consistently shows the same two VSS-related errors after Norton Ghost starts but before it fails. It makes no difference if the VSS service is started or stopped. The VSS errors do not appear elsewhere in the event log, only after Ghost starts. The MSS event messages, however, are quite common, appearing throughout the log, and they may have nothing to do with the problem. Here is the Norton Ghost error display... -Errors exist. --Unable to write to file. ---Error EBAB03F1: The specified network name is no longer available. ---Unable to set file size. ----Error EBAB03F1: The specified network name is no longer available. ----Unable to write to file. -----Error EBAB03F1: The specified network name is no longer available. -----Unable to set file size. ------Error EBAB03F1: The specified network name is no longer available. Here are the source computer events, with the final error at the top and the "Ghost Starting" message at the bottom: ===== Event Type: Error Event Source: Norton Ghost Event Category: High Priority Event ID: 100 Date: 11/09/2009 Time: 9:40:26 AM User: N/A Computer: PAVILION2 Description: Error EC8F17B7: Cannot create recovery points for job: Drive Backup of (C:\) (3). Error E7D1001F: Unable to write to file. Error EBAB03F1: The specified network name is no longer available. Error E7D10046: Unable to set file size. Error EBAB03F1: The specified network name is no longer available. Error E7D1001F: Unable to write to file. Error EBAB03F1: The specified network name is no longer available. Error E7D10046: Unable to set file size. Error EBAB03F1: The specified network name is no longer available. Details: 0xEBAB0005 Source: Norton Ghost ===== Event Type: Information Event Source: MSSQL$SQLEXPRESS Event Category: Server Event ID: 3421 Date: 11/09/2009 Time: 9:34:06 AM User: NT AUTHORITY\NETWORK SERVICE Computer: PAVILION2 Description: Recovery completed for database ReportServer$SQLEXPRESSTempDB (database ID 6) in 1 second(s) (analysis 205 ms, redo 0 ms, undo 376 ms.) This is an informational message only. No user action is required. For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. Data: 0000: 5d 0d 00 00 0a 00 00 00 ]....... 0008: 15 00 00 00 50 00 41 00 ....P.A. 0010: 56 00 49 00 4c 00 49 00 V.I.L.I. 0018: 4f 00 4e 00 32 00 5c 00 O.N.2.\. 0020: 53 00 51 00 4c 00 45 00 S.Q.L.E. 0028: 58 00 50 00 52 00 45 00 X.P.R.E. 0030: 53 00 53 00 00 00 18 00 S.S..... 0038: 00 00 52 00 65 00 70 00 ..R.e.p. 0040: 6f 00 72 00 74 00 53 00 o.r.t.S. 0048: 65 00 72 00 76 00 65 00 e.r.v.e. 0050: 72 00 24 00 53 00 51 00 r.$.S.Q. 0058: 4c 00 45 00 58 00 50 00 L.E.X.P. 0060: 52 00 45 00 53 00 53 00 R.E.S.S. 0068: 00 00 .. ===== Event Type: Information Event Source: MSSQL$SQLEXPRESS Event Category: Server Event ID: 17137 Date: 11/09/2009 Time: 9:34:02 AM User: NT AUTHORITY\NETWORK SERVICE Computer: PAVILION2 Description: Starting up database 'ReportServer$SQLEXPRESSTempDB'. For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. Data: 0000: f1 42 00 00 0a 00 00 00 ñB...... 0008: 15 00 00 00 50 00 41 00 ....P.A. 0010: 56 00 49 00 4c 00 49 00 V.I.L.I. 0018: 4f 00 4e 00 32 00 5c 00 O.N.2.\. 0020: 53 00 51 00 4c 00 45 00 S.Q.L.E. 0028: 58 00 50 00 52 00 45 00 X.P.R.E. 0030: 53 00 53 00 00 00 18 00 S.S..... 0038: 00 00 52 00 65 00 70 00 ..R.e.p. 0040: 6f 00 72 00 74 00 53 00 o.r.t.S. 0048: 65 00 72 00 76 00 65 00 e.r.v.e. 0050: 72 00 24 00 53 00 51 00 r.$.S.Q. 0058: 4c 00 45 00 58 00 50 00 L.E.X.P. 0060: 52 00 45 00 53 00 53 00 R.E.S.S. 0068: 00 00 .. ===== Event Type: Error Event Source: VSS Event Category: None Event ID: 5013 Date: 11/09/2009 Time: 9:28:32 AM User: N/A Computer: PAVILION2 Description: Volume Shadow Copy Service error: Shadow Copy writer ContentIndexingService called routine RegQueryValueExW which failed with status 0x80070002 (converted to 0x800423f4). For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. Data: 0000: 57 53 48 43 4f 4d 4e 43 WSHCOMNC 0008: 32 32 39 32 00 00 00 00 2292.... 0010: 57 53 48 43 49 43 00 00 WSHCIC.. 0018: 32 38 37 00 00 00 00 00 287..... ===== Event Type: Error Event Source: VSS Event Category: None Event ID: 5013 Date: 11/09/2009 Time: 9:28:32 AM User: N/A Computer: PAVILION2 Description: Volume Shadow Copy Service error: Shadow Copy writer ContentIndexingService called routine RegQueryValueExW which failed with status 0x80070002 (converted to 0x800423f4). For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. Data: 0000: 57 53 48 43 4f 4d 4e 43 WSHCOMNC 0008: 32 32 39 32 00 00 00 00 2292.... 0010: 57 53 48 43 49 43 00 00 WSHCIC.. 0018: 32 38 37 00 00 00 00 00 287..... ===== Event Type: Error Event Source: VSS Event Category: None Event ID: 12302 Date: 11/09/2009 Time: 9:28:32 AM User: N/A Computer: PAVILION2 Description: Volume Shadow Copy Service error: An internal inconsistency was detected in trying to contact shadow copy service writers. Please check to see that the Event Service and Volume Shadow Copy Service are operating properly. For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. Data: 0000: 42 55 45 43 58 4d 4c 43 BUECXMLC 0008: 33 36 33 37 00 00 00 00 3637.... 0010: 42 55 45 43 58 4d 4c 43 BUECXMLC 0018: 33 36 30 37 00 00 00 00 3607.... ===== Event Type: Information Event Source: Norton Ghost Event Category: High Priority Event ID: 100 Date: 11/09/2009 Time: 9:27:57 AM User: N/A Computer: PAVILION2 Description: Info 6C8F1F63: The drive-based backup job, Drive Backup of (C:\) (3), has been started manually. Details: Source: Norton Ghost

    Read the article

  • Norton Ghost EBAB03F1: The specified network name is no longer available

    - by Breck Carter
    After about 15 minutes, a Norton Ghost 14 backup fails with Error EBAB03F1: The specified network name is no longer available. The source computer is a P4 laptop running Windows XP SP3. The target computer is a Core2 Quad desktop running Windows Vista Ultimate 64bit. It does not help to disable Norton 360 on the source computer or Norton Antivirus 2008 on the target computer. The Event Viewer consistently shows the same two VSS-related errors after Norton Ghost starts but before it fails. It makes no difference if the VSS service is started or stopped. The VSS errors do not appear elsewhere in the event log, only after Ghost starts. The MSS event messages, however, are quite common, appearing throughout the log, and they may have nothing to do with the problem. Here is the Norton Ghost error display... -Errors exist. --Unable to write to file. ---Error EBAB03F1: The specified network name is no longer available. ---Unable to set file size. ----Error EBAB03F1: The specified network name is no longer available. ----Unable to write to file. -----Error EBAB03F1: The specified network name is no longer available. -----Unable to set file size. ------Error EBAB03F1: The specified network name is no longer available. Here are the source computer events, with the final error at the top and the "Ghost Starting" message at the bottom: ===== Event Type: Error Event Source: Norton Ghost Event Category: High Priority Event ID: 100 Date: 11/09/2009 Time: 9:40:26 AM User: N/A Computer: PAVILION2 Description: Error EC8F17B7: Cannot create recovery points for job: Drive Backup of (C:\) (3). Error E7D1001F: Unable to write to file. Error EBAB03F1: The specified network name is no longer available. Error E7D10046: Unable to set file size. Error EBAB03F1: The specified network name is no longer available. Error E7D1001F: Unable to write to file. Error EBAB03F1: The specified network name is no longer available. Error E7D10046: Unable to set file size. Error EBAB03F1: The specified network name is no longer available. Details: 0xEBAB0005 Source: Norton Ghost ===== Event Type: Information Event Source: MSSQL$SQLEXPRESS Event Category: Server Event ID: 3421 Date: 11/09/2009 Time: 9:34:06 AM User: NT AUTHORITY\NETWORK SERVICE Computer: PAVILION2 Description: Recovery completed for database ReportServer$SQLEXPRESSTempDB (database ID 6) in 1 second(s) (analysis 205 ms, redo 0 ms, undo 376 ms.) This is an informational message only. No user action is required. For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. Data: 0000: 5d 0d 00 00 0a 00 00 00 ]....... 0008: 15 00 00 00 50 00 41 00 ....P.A. 0010: 56 00 49 00 4c 00 49 00 V.I.L.I. 0018: 4f 00 4e 00 32 00 5c 00 O.N.2.\. 0020: 53 00 51 00 4c 00 45 00 S.Q.L.E. 0028: 58 00 50 00 52 00 45 00 X.P.R.E. 0030: 53 00 53 00 00 00 18 00 S.S..... 0038: 00 00 52 00 65 00 70 00 ..R.e.p. 0040: 6f 00 72 00 74 00 53 00 o.r.t.S. 0048: 65 00 72 00 76 00 65 00 e.r.v.e. 0050: 72 00 24 00 53 00 51 00 r.$.S.Q. 0058: 4c 00 45 00 58 00 50 00 L.E.X.P. 0060: 52 00 45 00 53 00 53 00 R.E.S.S. 0068: 00 00 .. ===== Event Type: Information Event Source: MSSQL$SQLEXPRESS Event Category: Server Event ID: 17137 Date: 11/09/2009 Time: 9:34:02 AM User: NT AUTHORITY\NETWORK SERVICE Computer: PAVILION2 Description: Starting up database 'ReportServer$SQLEXPRESSTempDB'. For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. Data: 0000: f1 42 00 00 0a 00 00 00 ñB...... 0008: 15 00 00 00 50 00 41 00 ....P.A. 0010: 56 00 49 00 4c 00 49 00 V.I.L.I. 0018: 4f 00 4e 00 32 00 5c 00 O.N.2.\. 0020: 53 00 51 00 4c 00 45 00 S.Q.L.E. 0028: 58 00 50 00 52 00 45 00 X.P.R.E. 0030: 53 00 53 00 00 00 18 00 S.S..... 0038: 00 00 52 00 65 00 70 00 ..R.e.p. 0040: 6f 00 72 00 74 00 53 00 o.r.t.S. 0048: 65 00 72 00 76 00 65 00 e.r.v.e. 0050: 72 00 24 00 53 00 51 00 r.$.S.Q. 0058: 4c 00 45 00 58 00 50 00 L.E.X.P. 0060: 52 00 45 00 53 00 53 00 R.E.S.S. 0068: 00 00 .. ===== Event Type: Error Event Source: VSS Event Category: None Event ID: 5013 Date: 11/09/2009 Time: 9:28:32 AM User: N/A Computer: PAVILION2 Description: Volume Shadow Copy Service error: Shadow Copy writer ContentIndexingService called routine RegQueryValueExW which failed with status 0x80070002 (converted to 0x800423f4). For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. Data: 0000: 57 53 48 43 4f 4d 4e 43 WSHCOMNC 0008: 32 32 39 32 00 00 00 00 2292.... 0010: 57 53 48 43 49 43 00 00 WSHCIC.. 0018: 32 38 37 00 00 00 00 00 287..... ===== Event Type: Error Event Source: VSS Event Category: None Event ID: 5013 Date: 11/09/2009 Time: 9:28:32 AM User: N/A Computer: PAVILION2 Description: Volume Shadow Copy Service error: Shadow Copy writer ContentIndexingService called routine RegQueryValueExW which failed with status 0x80070002 (converted to 0x800423f4). For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. Data: 0000: 57 53 48 43 4f 4d 4e 43 WSHCOMNC 0008: 32 32 39 32 00 00 00 00 2292.... 0010: 57 53 48 43 49 43 00 00 WSHCIC.. 0018: 32 38 37 00 00 00 00 00 287..... ===== Event Type: Error Event Source: VSS Event Category: None Event ID: 12302 Date: 11/09/2009 Time: 9:28:32 AM User: N/A Computer: PAVILION2 Description: Volume Shadow Copy Service error: An internal inconsistency was detected in trying to contact shadow copy service writers. Please check to see that the Event Service and Volume Shadow Copy Service are operating properly. For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. Data: 0000: 42 55 45 43 58 4d 4c 43 BUECXMLC 0008: 33 36 33 37 00 00 00 00 3637.... 0010: 42 55 45 43 58 4d 4c 43 BUECXMLC 0018: 33 36 30 37 00 00 00 00 3607.... ===== Event Type: Information Event Source: Norton Ghost Event Category: High Priority Event ID: 100 Date: 11/09/2009 Time: 9:27:57 AM User: N/A Computer: PAVILION2 Description: Info 6C8F1F63: The drive-based backup job, Drive Backup of (C:\) (3), has been started manually. Details: Source: Norton Ghost

    Read the article

  • .NET SerialPort DataReceived event not firing

    - by Klay
    I have a WPF test app for evaluating event-based serial port communication (vs. polling the serial port). The problem is that the DataReceived event doesn't seem to be firing at all. I have a very basic WPF form with a TextBox for user input, a TextBlock for output, and a button to write the input to the serial port. Here's the code: public partial class Window1 : Window { SerialPort port; public Window1() { InitializeComponent(); port = new SerialPort("COM2", 9600, Parity.None, 8, StopBits.One); port.DataReceived += new SerialDataReceivedEventHandler(port_DataReceived); port.Open(); } void port_DataReceived(object sender, SerialDataReceivedEventArgs e) { Debug.Print("receiving!"); string data = port.ReadExisting(); Debug.Print(data); outputText.Text = data; } private void Button_Click(object sender, RoutedEventArgs e) { Debug.Print("sending: " + inputText.Text); port.WriteLine(inputText.Text); } } Now, here are the complicating factors: The laptop I'm working on has no serial ports, so I'm using a piece of software called Virtual Serial Port Emulator to setup a COM2. VSPE has worked admirably in the past, and it's not clear why it would only malfunction with .NET's SerialPort class, but I mention it just in case. When I hit the button on my form to send the data, my Hyperterminal window (connected on COM2) shows that the data is getting through. Yes, I disconnect Hyperterminal when I want to test my form's ability to read the port. I've tried opening the port before wiring up the event. No change. I've read through another post here where someone else is having a similar problem. None of that info has helped me in this case. EDIT: Here's the console version (modified from http://mark.michaelis.net/Blog/TheBasicsOfSystemIOPortsSerialPort.aspx): class Program { static SerialPort port; static void Main(string[] args) { port = new SerialPort("COM2", 9600, Parity.None, 8, StopBits.One); port.DataReceived += new SerialDataReceivedEventHandler(port_DataReceived); port.Open(); string text; do { text = Console.ReadLine(); port.Write(text + "\r\n"); } while (text.ToLower() != "q"); } public static void port_DataReceived(object sender, SerialDataReceivedEventArgs args) { string text = port.ReadExisting(); Console.WriteLine("received: " + text); } } This should eliminate any concern that it's a Threading issue (I think). This doesn't work either. Again, Hyperterminal reports the data sent through the port, but the console app doesn't seem to fire the DataReceived event. EDIT #2: I realized that I had two separate apps that should both send and receive from the serial port, so I decided to try running them simultaneously... If I type into the console app, the WPF app DataReceived event fires, with the expected threading error (which I know how to deal with). If I type into the WPF app, the console app DataReceived event fires, and it echoes the data. I'm guessing the issue is somewhere in my use of the VSPE software, which is set up to treat one serial port as both input and output. And through some weirdness of the SerialPort class, one instance of a serial port can't be both the sender and receiver. Anyway, I think it's solved.

    Read the article

  • event capturing or bubbling

    - by ChampionChris
    I have a link button in a repeater control. the li element is drag and droppable using jquery. when the page loads the the link button works perfectly, the jquery that is attached and the server side code both execute. when I perform a drag and drop then click on the link button it doesn't not fire. when i click it a second time it does fire. If i perform 2 or drag and drops in a row the link button doesn't fire a as many drag and drops as i before it will fire. for example if if perform 3 drag and drops then it will take about 3 click before the events are fired. <asp:Repeater ID="rTracks" runat="server" OnItemDataBound="rTracks_ItemDataBound" EnableViewState="true"> <ItemTemplate> <li onclick="testclick();" class='admin-song ui-selectee <asp:Literal id="ltStatusClass" runat="server" />' mediaid="<%# Eval("MediaId") %>" artistid="<%# Eval("tbMedia.tbArtists.id") %>"><span class="handle"><strong> <%--<%# int.Parse(DataBinder.Eval(Container, "ItemIndex", "")) + 1%>--%><%# Eval("SortNumber")%></strong><%--0:03--%></span> <span class="play"><span class="btn-play">&nbsp;</span></span> <span class="track" title="<%# Eval("tbMedia.Title") %>"> <%# Eval("tbMedia.Title") %></span> <span class="artist"> <%# Eval("tbMedia.tbArtists.Name") %></span> <span class="time" length="<%# Eval("tbMedia.Length") %>"> <asp:Literal ID="ltRuntime" runat="server" /></span> <span class="notes"><span class="btn-notes"> <asp:Literal ID="ltNotesCount" runat="server" /></span></span> <span class="status"> <asp:Literal ID="ltStatus" runat="server" /></span> <span class="date"> <%# Eval("DateAdded") %></span> <span class="remove"><asp:LinkButton ID="lbStatusClass2" runat="server" CssClass="btn-del" OnClick="UpdateStatus" ValidationGroup='<%#Bind("MediaId") %>'> <%--<span class='<asp:Literal id="ltStatusClass2" runat="server" Text="btn-del" />'>--%> &nbsp;<%--</span>--%></asp:LinkButton></span></span> </li> </ItemTemplate> </asp:Repeater> I have onclick event on the li element, when the mouse is clicks the link button the li onclick event is fired even when linkbutton event doesnt fire. My question is if the li captures the event y doesnt the event fire on the linkbutton? What would be stopping the event?

    Read the article

  • DNS Client Event 1012: Error reading local hosts file

    - by Sam
    My notebook boots extreme slowly and shows loads of the following error in the event log: Error reading local hosts file Source: DNS Client Events EventID: 1012 The computer is quite new, I kind of just finished installing. So I don't feel like installing everything again (especially since this probably would result in the same problem anyway). Any idea how to resolve this? Thanks, Sam

    Read the article

  • Remote Desktop event ID 20499. No noticeable issues

    - by Marc05
    I get a warning event with ID 20499 for TerminalServices-RemoteConnectionManager.The error is: Remote Desktop Services has taken too long to load the user configuration from server \server.domain.home for user administrator. Yet, I don't see any issues (I'm guessing because that user is on the machine local). Why am I getting this warning? I'm on Windows Server 2012 R2 connecting from a Windows 8.1.

    Read the article

  • Logging Virus Definition Updates for MS Security Essentials in The Security Event Log

    - by Steve
    I would like to log a security in event in Windows 7 whenever the Microsoft Security Essentials 2 virus definition files are updates, deleted, or changed. I was expecting to do this with an Audit setting on one of the MS Security Essentials folders but I wasn't sure which one and how to avoid getting swamped with messages. What folder or files should I audit to track definition updates (or corruption) in the security events or is there a better approach?

    Read the article

  • Opsview Notifications, how to report event duration

    - by dotwaffle
    At present, Opsview reports recoveries in the following format: RECOVERY: Internal Alarm is OK on host Ellie: SNMP OK - 0 Service: Internal Alarm Host: Ellie Alias: Ellie Address: 1.2.3.4 State: OK Comment: () Date/Time: Mon Oct 5 14:57:53 BST 2009 Additional Info: SNMP OK - 0 What I would ideally like to do is add a "duration" field, so that you can tell without scrolling back on a Blackberry how long the event has been at fault for. Is there an easy solution to this?

    Read the article

  • Hotfix entries in event log

    - by Marco Shaw
    Server 2008/2008 R2 I'm trying to remotely monitor these servers to watch the progress of hotfixes being installed. I was able to find this in Server 2003/2003 R2: -Log: System -Source: NtServicePack It seems the above event is written when every hotfix is installed. I can't seem to find a comparable entry in Server 2008/2008 R2 though. Is there anything similar that I can easily monitor for remotely?

    Read the article

  • Online Event management

    - by cKK
    Hi looking for an events management solution. Admins would be able to create new event pages with information and booking forms that connect to a payment gateway. Most of what I've seen is outdated and hard to use and back office intergration is zero or minimal. the front end pages are dull and use frames!! Looking for upto date online software similar to what they are doing with Email marketing solutions (interspire, mailchimp) these application are easy to use and look the business. Thanks

    Read the article

  • Opsview Notifications, how to report event duration

    - by dotwaffle
    At present, Opsview reports recoveries in the following format: RECOVERY: Internal Alarm is OK on host Ellie: SNMP OK - 0 Service: Internal Alarm Host: Ellie Alias: Ellie Address: 1.2.3.4 State: OK Comment: () Date/Time: Mon Oct 5 14:57:53 BST 2009 Additional Info: SNMP OK - 0 What I would ideally like to do is add a "duration" field, so that you can tell without scrolling back on a Blackberry how long the event has been at fault for. Is there an easy solution to this?

    Read the article

  • Remote Server: Please wait for the System Event Notification Service

    - by Jeff Handley
    I was rebooting a remote server (Windows Server 2008 R2 Standard) over remote desktop and the session now shows the blue screen during the shutdown sequence, and the message "Please wait for the System Event Notification Service..." It seems that everything is still running on the server (for instance, http://jeffhandley.com is still responding), but I need to get the machine to finish the reboot sequence. How can I force the machine past this point? It's been stuck there for about 30 minutes.

    Read the article

  • Form Search Onkeyup event

    - by Aryan
    I Have a Form In which the form should automatically search when i complete entering the 10th character in the text field but the below code is searching for each n every character i enter in the text field . . . I just want the result after completing the 10th character not for each n every character . . i have used onkeyup event and i set that value to 10 but still it is searching for each n every character... please do help me <body OnKeyPress="return disableKeyPress(event)"> <section id="content" class="container_12 clearfix" data-sort=true> <center><table class='dynamic styled with-prev-next' data-table-tools='{'display':true}' align=center> <script> function disableEnterKey(e) { var key; if(window.event) key = window.event.keyCode; //IE else key = e.which; //firefox return (key != 13); } function showUser(str) { if (str=="") { document.getElementById("txtHint").innerHTML=""; return; } if (window.XMLHttpRequest) {// code for IE7+, Firefox, Chrome, Opera, Safari xmlhttp=new XMLHttpRequest(); } else {// code for IE6, IE5 xmlhttp=new ActiveXObject("Microsoft.XMLHTTP"); } xmlhttp.onreadystatechange=function() { if (xmlhttp.readyState==4 && xmlhttp.status==200) { document.getElementById("txtHint").innerHTML=xmlhttp.responseText; } } xmlhttp.open("GET","resdb.php?id="+str,true); xmlhttp.send(); } </script> <script type='text/javascript'> //<![CDATA[ $(window).load(function(){ $('#id').keyup(function(){ if(this.value.length ==10) }); });//]]> </script> <form id="form" method="post" name="form" > <tr><td><p align="center"><font size="3"><b>JNTUH - B.Tech IV Year II Semester (R07) Advance Supplementary Results - July 2012</b></font></p></td></tr> <td><p align="center"><b>Last Date for RC/RV : 8th August 2012</b></p></td> <tr><td><p align="center"></b> <input type="text" onkeyup="showUser(this.value)" onKeyPress="return disableEnterKey(event)" data-type="autocomplete" data-source="extras/autocomplete1.php" name="id" id="id" maxlength="10" placeholder=" Hall-Ticket Number">&emsp;</p></td></tr> </table> </center> </form> <center> <div id="txtHint"><b>Results will be displayed here</b></div> </center> </body>

    Read the article

  • Sage 50 Accounts 2010 wont run on windows 7

    - by admintech
    I have sucessfuly installed Sage 50 Accounts 2010 onto my 32 bit Windows 7 machine, yet whenever i try to run it i encounter - Log Name: Application Source: Application Error Date: 24/05/2010 17:14:13 Event ID: 1000 Task Category: (100) Level: Error Keywords: Classic User: N/A Computer: LukeThomas-PC.domain.co.uk Description: Faulting application name: Sage.SBD.Platform.Installation.SoftwareUpdates.UI.exe, version: 2.0.0.91, time stamp: 0x4a8c22fe Faulting module name: igdumd32.dll, version: 8.15.10.1872, time stamp: 0x4a848a05 Exception code: 0xc0000409 Fault offset: 0x00012f96 Faulting process id: 0x1778 Faulting application start time: 0x01cafb5c2493b609 Faulting application path: C:\Program Files\Common Files\Sage SBD\Sage.SBD.Platform.Installation.SoftwareUpdates.UI.exe Faulting module path: C:\Windows\system32\igdumd32.dll Report Id: 63e2246b-674f-11df-96ba-002564c97988 Event Xml: 1000 2 100 0x80000000000000 5062 Application LukeThomas-PC.domain.co.uk Sage.SBD.Platform.Installation.SoftwareUpdates.UI.exe 2.0.0.91 4a8c22fe igdumd32.dll 8.15.10.1872 4a848a05 c0000409 00012f96 1778 01cafb5c2493b609 C:\Program Files\Common Files\Sage SBD\Sage.SBD.Platform.Installation.SoftwareUpdates.UI.exe C:\Windows\system32\igdumd32.dll 63e2246b-674f-11df-96ba-002564c97988 Any help would be appreciated as i cant find anything about this error

    Read the article

  • FB.Event.subscribe + comments.add don't work !?

    - by user366292
    I'm trying to catch event when comment is sent. What am I doing wrong? I just want to update every user comment also to facebook group wall and that's why I need to catch the event. <fb:comments numposts="10" ></fb:comments> FB.init and event catcher: <div id="fb-root"></div> <script> window.fbAsyncInit = function() { FB.init({ appId : 'sensored-app-id', status : true, // check login status cookie : true, // enable cookies to allow the server to access the session xfbml : true // parse XFBML }); /* All the events registered */ FB.Event.subscribe('comments.add', function (response) { // do something with response alert("comment added"); }); }; (function() { var e = document.createElement('script'); e.src = document.location.protocol + '//connect.facebook.net/fi_FI/all.js'; e.async = true; document.getElementById('fb-root').appendChild(e); }()); </script>

    Read the article

  • Actionscript 3: Force program to wait until event handler is called

    - by Jeremy Swinarton
    I have an AS 3.0 class that loads a JSON file in using a URLRequest. package { import flash.display.MovieClip; import flash.display.Loader; import flash.net.URLRequest; import flash.net.URLLoader; import flash.events.Event; public class Tiles extends MovieClip { private var mapWidth:int,mapHeight:int; private var mapFile:String; private var mapLoaded:Boolean=false; public function Tiles(m:String) { init(m); } private function init(m:String):void { // Initiates the map arrays for later use. mapFile=m; // Load the map file in. var loader:URLLoader = new URLLoader(); loader.addEventListener(Event.COMPLETE, mapHandler); loader.load(new URLRequest("maps/" + mapFile)); } private function mapHandler(e:Event):void { mapLoaded=true; mapWidth=3000; } public function getMapWidth():int { if (mapLoaded) { return (mapWidth); } else { getMapWidth(); return(-1); } } } } When the file is finished loading, the mapHandler event makes changes to the class properties, which in turn are accessed using the getMapWidth function. However, if the getMapwidth function gets called before it finishes loading, the program will fail. How can I make the class wait to accept function calls until after the file is loaded?

    Read the article

  • Visual C# GUI Designer - Recommended way of removing generated event handler-code & basic tutorial

    - by cusack
    Hi, I'm new to the Visual C# designer so these are general and pretty basic question on how to work with the designer. When we for instance add a label to a form and then double-click on it in the Visual C# designer (I'm using Microsoft Visual C# 2008 Express Edition), the following things happen: The designer generates code within Form1.Designer.cs (assume default names for simplicity) to add the label, then with the double-click it will add the event handler label1_Click to the label within Form1.Designer.cs, using the following code this.label1.Click += new System.EventHandler(this.label1_Click); and it adds the event handler method to Form1.cs private void label1_Click(object sender, EventArgs e) { } If I now remove the label only the code within Form1.Designer.cs will be removed but the label1_Click method will stay within Form1.cs even if it isn't used by anything else. But if I'm using reset within Properties-Events for the Click-event from within the designer even the label1_Click method in Form1.cs will be removed. 1.) Isn't that a little inconsistent behavior? 2.) What is the recommended way of removing such generated event handler-code? 3.) What is the best "mental approach"/best practice for using the designer? I would approach it by mental separation in the way that Form1.cs is 100% my responsibility and that on the other hand I'm not touching the code in Form1.Designer.cs at all. Does that make sense or not? Since sometimes the designer removes sth. from Form1.cs I'm not sure about this. 4.) Can you recommend a simple designer tutorial that assumes no Visual C# designer knowledge but expects/doesn't explain C#. The following one is an example of what I would not want it explains what a c#-comment is and I'd prefer text over video as well: http://msdn.microsoft.com/en-us/beginner/bb964631.aspx

    Read the article