Search Results

Search found 1116 results on 45 pages for 'nic dk'.

Page 39/45 | < Previous Page | 35 36 37 38 39 40 41 42 43 44 45  | Next Page >

  • What steps should I take to debug this non-starting hvm virtual machine?

    - by Ophidian
    I have a dom0 machine running CentOS 5.4 with all the latest updates using Xen as my hypervisor. I am using Xen in part because this machine was set up prior to KVM being included in RHEL, and in part because KVM's network bridging configuration is not nearly as simple as Xen's. The dom0 machine is headless and I do all of my VM management via virsh from the command line. I have two hvm domU's: A web server running CentOS 5.4 A mail server running Gentoo Both VM's are backed by LV's on the dom0 but do not use LVM in the domU. Both have virtually identical libvirt configurations (differing by expected things like name, UUID, NIC MAC, VNC port, etc). The web server domU (WSdomU hereafter) does not start since applying the most recent kernel update (kernel-xen-2.6.18-164.15.1.el5.x86_64 and kernel-2.6.18-164.15.1.el5.x86_64 for the dom0 and WSdomU respectively). By 'not start' I mean it appears to be running but it does not use an CPU cycles, does not bring up a graphical console, and does not respond on the network. The WSdomU is listed as no state rather than the normal running or blocked in xentop. The mail server domU starts fine and functions normally. Here are the steps I have taken so far that did not solve the problem: Reboot the dom0 to see if things come up on their own Check xen dmesg on dom0 Check xend logs (a cursory viewing did not show anything blatant; specific suggestions of things to look for would be appreciated) Attempted to connect to the WSdomU's graphical (VNC) console from the dom0 Shutdown the mail server domU and attempt to start the WSdomU Check the SELinux labels on backing LV's (they're the same) Set SELinux to permissive and attempt to start the WSdomU Use virsh edit to try tweaking the WSdomU config virsh undefine, reboot, virsh define the WSdomU config dd the WSdomU LV to an .img file, copy it to my Fedora desktop and run it under KVM (works fine) What steps should I take next to debug this? I will edit in any additional configuration's requested in the comments.

    Read the article

  • PC won't PXE boot to WDS/MDT with Dell Optiplex 755

    - by Moman10
    I am trying to set up a basic MDT solution. I have set one up in the past at a previous job and it worked flawlessly, however here I'm running into a problem and am having no luck getting around it. I've installed Windows Server 2012 and MDT 2013, along with adding on the WDS role. I haven't configured much outside of the defaults for WDS, basically just set PXE response to respond to all clients (and unchecked admin approval). This machine does not run a DHCP server. I looked on the DHCP scope of our DHCP server, it shows options 66/67 checked and the server name of the WDS server is in there as well. I didn't add this but I assume it was put on during the install process (I believe I had to manually make some adjustments at my old job for this). The PC I have is a Dell Optiplex 755. I have enabled the onbard NIC w/PXE boot option in BIOS and attempted to boot. I get a "TFTP...." error but nothing offering out a DHCP address like I'm used to. In my previous job it pretty much worked right out of the box. I've verified that PortFast is enabled on the port and I've tried a couple different PCs (but both are the same model, only model I have to work with). No matter what, I get the same error. The subnet the PC is in is a different subnet than where the WDS server is sitting, but there are IP helper statements on the switch and the PCs can get regular DHCP addresses just fine from the DHCP server, just doesn't seem to get offered out a PXE boot option. I don't know if the problem is a configuration with the server or the PC itself...but after a few days of Googling I'm running out of ideas. Does anyone have a good idea of something it may be?

    Read the article

  • Getting SMB file shares working over a PPTP VPN

    - by Ben Scott
    I'm having issues getting SMB file shares working over a PPTP VPN. The server setup consists of a security device (DrayTek V3300) which passes the PPTP authentication to a SBS2003 server running RRAS. The server is the DC and provides DNS and WINS, the single NIC's name server is set to 127.0.0.1, and DHCP on the DrayTek sets the server IP as the DNS. If I create a new VPN connection in Win7, leaving everything as default apart from the server, username, password and domain, I can: ping everything by IP address resolve IPs with nslookup using their fully-qualified name, as in nslookup fileserver.mydomain.local ping machines by fully-qualified name, as in ping fileserver.mydomain.local However if I try to access a file share: within Explorer, I get "Windows cannot access ..." with "Error code: 0x80004005 Unspecified Error", using net use z: \\fileserver.mydomain.local\share, I get "System error 53 has occurred. The network path was not found." If I add the machine name to my HOSTS file I can use the file share, which is my last-ditch workaround, but I have a number of VPN users and would rather a solution that doesn't involve me trying to hand-edit system files on computers half a country away. If I set the WINS server explicitly in the connection's IPv4 settings I don't have to use the FQN to ping the machine, but that doesn't change anything else.

    Read the article

  • HP Proliant DL380 G4 - Can this server still perform in 2011?

    - by BSchriver
    Can the HP Proliant DL380 G4 series server still perform at high a quality in the 2011 IT world? This may sound like a weird question but we are a very small company whose primary business is NOT IT related. So my IT dollars have to stretch a long way. I am in need of a good web and database server. The load and demand for a while will be fairly low so I am not looking nor do I have the money to buy a brand new HP Dl380 G7 series box for $6K. While searching around today I found a company in ATL that buys servers off business leases and then stripes them down to parts. They clean, check and test each part and then custom "rebuild" the server based on whatever specs you request. The interesting thing is they also provide a 3-year warranty on all their servers they sell. I am contemplating buying two of the following: HP Proliant DL380 G4 Dual (2) Intel Xeon 3.6 GHz 800Mhz 1MB Cache processors 8GB PC3200R ECC Memory 6 x 73GB U320 15K rpm SCSI drives Smart Array 6i Card Dual Power Supplies Plus the usual cdrom, dual nic, etc... All this for $750 each or $1500 for two pretty nicely equipped servers. The price then jumps up on the next model up which is the G5 series. It goes from $750 to like $2000 for a comparable server. I just do not have $4000 to buy two servers right now. So back to my original question, if I load Windows 2008 R2 Server and IIS 7 on one of the machines and Windows 2008 R2 server and MS SQL 2008 R2 Server on another machine, what kind of performance might I expect to see from these machines? The facts is this series is now 3 versions behind the G7's and this series of server was built when Windows 200 Server was the dominant OS and Windows 2003 Server was just coming out. If you are running Windows 2008 R2 Server on a G4 with similar or less specs I would love to hear what your performance is like.

    Read the article

  • Intranet Setup for Small business any resources?

    - by Rogue
    Want to setup an intranet for a small business setup. Current Setup 28 computers running Windows ( few older pc's run Windows Xp but most run Windows 7) Spare Dell Pentium 3 which can run as a server. 6 switches spare NIC's and lots of lan cable available for networking. 3 Independent Internet connections Currently we have 3 independent networks which share internet connections, each network uses a different internet connection. Current network is setup solely to share the internet connection. What I need to achieve in this intranet Setup one common network. Instant file transfer via local network (maybe setup a file server?) Local text and voice messenger software Bridge the 3 internet connections and route all the internet connections from the main server Ability to allow or deny internet access to any computer on the network. Remote access from the main server to the client pc's on the network to debug software issues What operating system should I use on the main server? Do I need a hardware firewall? Any setup guides / resources or how-to's on how I can achieve the above requirements.

    Read the article

  • KVM error with device pass through

    - by javano
    I am running the following command booting a Debian live CD passing a host PCI device to the guest as a test and KVM errors out; kvm -m 512 -boot c -net none -hda /media/AA502592502565F3/debian.iso -device pci-assign,host=07:00.0 PCI region 1 at address 0xf7920000 has size 0x80, which is not a multiple of 4K. You might experience some performance hit due to that. No IOMMU found. Unable to assign device "(null)" kvm: -device pci-assign,host=07:00.0: Device 'pci-assign' could not be initialized lspci | grep 07 07:00.0 Ethernet controller: 3Com Corporation 3c905C-TX/TX-M [Tornado] (rev 74) I shoved an old spare NIC into my motherboard to test PCI pass through. I have searched the Internet with Goolge and found that errors relating to "No IOMMU found" often mean the PCI device is not supported by KVM. Does KVM have to support the device being "passed-through"? I though the point was to pass the device through and let the guest worry about it? Ultimately I want to pass-through a PCI random number generator, is this not going to be possible with KVM? Thank you.

    Read the article

  • Can't access one directory via HTTPS + public FQDN

    - by Justin James
    Hello - I have the strangest IIS error that I've ever seen in my life. I have an application/directory on an IIS server, that throws an error 500 when accessing ANY of the content in it, including HTML documents, when accessed via HTTPS AND the machines FQDN. When I access it with "localhost" it works fine. When I added a bogus entry for the NIC's IP in the hosts file, it worked fine. When I access it with the machines name and HTTP it works fine. Here's a chart (the machine's name is "lofn.titaniumcrowbar.com"): http - lofn.titaniumcrowbar.com: works https - lofn.titaniumcrowbar.com: broken https - localhost: works https - temp.titaniumcrowbar.com (put into hosts file): works I set up tracing, and I got some useless information: "The I/O operation has been aborted because of either a thread exit or an application request. (0x800703e3)" This would make sense, except this happens when pulling up static content. While the directory may be an "application", the content is all static in it. Any/all suggestions, no matter how strange, are VERY appreciated. Thanks! J.Ja

    Read the article

  • How can I determine what is killing my network adapter win7 or vista?

    - by datatoo
    I thought this issue was like another person here, and that downloading the nvidia chipset drivers was the solution. However that is not all that is going on. This machine had Vista 64bit and is now Win7. Same issue with both. I have explicitly been denying network driver updates since getting things working again and when a Windows updates occurs on seemingly benign Office updates the adapter fails to work. Is the update process somehow protecting this machine by turning off things and it fails to recover connectivity after a restart? All that seems to ever work is a system restore. Which does work. Since there are 25 pending updates asking to do there thing, I hate to think this is a one by one update test to find the culprit. Any ideas? This has an integrated nic, video, and I guess audio on the motherboard. ES5200 intel cpu on a gateway 4800-05e I am not quite sure how to determine the actual network adapter. This is a wired adapter. I suppose worst case I can try another adapter if this keeps happening.

    Read the article

  • centos 6.3 kvm external ip forwarding to guests

    - by user1111702
    I have a centos 6.3 server with kvm installed. The server has 4 external ips and one NIC. 176.9.xxx.xx1 176.9.xxx.xx2 176.9.xxx.xx3 176.9.xxx.xx4 I use the following configuration ifcfg-eth0 as slave to ifcfg-br0 the configuration in ifcfg-eth0 is DEVICE=eth0 ONBOOT=yes BRIDGE=br0 HWADDR=14:da:e9:b3:8b:99 and in the ifcfg-br0 DEVICE=br0 TYPE=Bridge BOOTPROTO=static BROADCAST=176.9.xxx.xxx IPADDR=176.9.xxx.xx1 NETMASK=255.255.255.0 SCOPE="peer 176.9.xxx.xxx" and I have 3 more aliases for br0 , br0:1 to get the trafic from the second external ip DEVICE=br0:1 IPADDR=176.9.xxx.xx2 NETMASK=255.255.255.248 ONBOOT=yes br0:2 to get the trafic from the third external ip DEVICE=br0:1 IPADDR=176.9.xxx.xx3 NETMASK=255.255.255.248 ONBOOT=yes br0:3 to get the trafic from the second external ip DEVICE=br0:1 IPADDR=176.9.xxx.xx4 NETMASK=255.255.255.248 ONBOOT=yes The above settings work fine and I recieve the trafic from all the external ips. My problem is that I want to pass the trafic from external ip to specific virtual guest on my server. ie trafic that comes from 176.9.xxx.xxx2 must pass to virtual machine 1 176.9.xxx.xxx3 must pass to virtual machine 2 176.9.xxx.xxx4 must pass to virtual machine 3 Can you please help me how to achieve this ? What are the settings on the host and what should I do to the guests. Thank you in advance

    Read the article

  • iSCSI performance questions

    - by RyanLambert
    Hi everyone, apologies for the long-winded post in advance... Attempting to troubleshoot some iSCSI sluggishness on a brand new vSphere deployment (still in test). Layout is as such: 3 VSphere hosts, each with 2x 10GB NICs plugged into a pair of Nexus 5020s with a 10gig back-to-back between them. NICs are port-channeled in an active/active redundant fashion (using vPC-mac pinning for those of you familiar with N1KV) Both NICs carry service console, vmotion, iSCSI, and guest traffic. iSCSI is on a single subnet/single VLAN that is not routed through our IP network (strictly layer2) Had this been a 1gig deployment, we probably would have split the iSCSI traffic off onto separate NICs, but the price/port gets rather ridiculous when you start throwing 4+ NICs to a server in a 10gigabit infrastructure, and I'm not really convinced it's necessary. Open to dialogue/tech facts re: this, though. At this point even a single VM guest will boot slowly to iSCSI storage (EMC CX4 on the same Nexus 5020 10gig switches), and restores of VMs from iSCSI take about twice as long as we'd expect them to. Our server folks mentioned that if we split the iSCSI off onto its own NIC, performance seems significantly better. From a network perspective, I've run through the variables I can think of (port configuration errors, MTU problems, congestion etc.) and I'm coming up dry. There really is no other traffic on these hosts other than the very specific test being performed at the time. Important thing to note is that guest traffic works just fine... it seems storage is the only thing affected by whatever gremlin exists. Concluding that we're not 'overutilizing' the network infrastructure since we're doing hardly anything, I'm just looking for some helpful tips/ideas we can use to resolve this... preferably without hurling extra 10gig NICs that are going to sit around 10% utilization while we've got 70+% left on our others.

    Read the article

  • Failure to obtain IP with ARP over Wi-Fi with personal Wi-Fi router in client mode

    - by axk
    I'm trying to connect a Samsung TV to the Internet using a TL-MR3020 personal wireless router in client mode. The TV fails to connect to the network. It sees the ethernet cable connected though. Here's my network topology: Here's what I've captured with Wireshark filtering for ARP (eth.type == 0x0806): It appears the TV fails to get the IP of the gateway (DSL modem/router) for some reason. One thing I've noticed is that the source MAC for the ARP requests coming from the TV is the MAC of the Portable wireless router (that is cd:89:00), not the TV itself and the modem sends the responses to that MAC (I'm not an expert and don't know if its okay or it may make the TV fail to get the requested IP). Also I'm able to ping the TV from the DSL router (through the telnet interface) and the router has an entry in its MAC table for the TV's IP with the Portable wireless router's MAC (that is cd:89:00). If I'm able to ping the TV I suppose it should know the router's MAC to respond to the ping, but then why these continuous ARP requests... I've also tried to connect my desktop trough this Portable wireless router the same way I'm trying to connect the TV and it works fine, I can set the DSL Modem's IP as the default gateway on the desktop's NIC and connect to the Internet. The TV can connect to the Internet when connected to the DSL Router with a wired connection. Any suggestions on what may be the cause of the problem / how to further debug it are welcome. Thanks!

    Read the article

  • Network speed between a VM and another machine which is not residing on the same host, is 11MB/s at most

    - by Henno
    Problem Network speed between a VM and another machine which is not residing on the same host, is 11MB/s at most. Topology Facts ESXi5 version is 5.0.0.504890 VM has the latest Vmware Tools installed VM is using E1000 network driver Physical box has Win Srv 2008 R2 as the OS CrystalDiskMark says the drive on physical box can read/write 100MB/s vCenter is another vm on esx both vm and physical box are showing 1Gbps link speed Configuration Networking shows vmnic0 as 1000 Full NTttcp is a client/server tool from Microsoft for measuring pure network throughput Here's what I've done so far: Test1: VM is running Filezilla FTP Server (default settings, one user account made) Physical box is running Filezilla FTP Client (default settings) Physical box is uploading a big file to FTP server Transfer speed (as observed by Windows Task Manager on both machines): ~11MB/s (bad) Physical box is downloading that file from FTP server Transfer speed (as observed by Windows Task Manager on both machines): still ~11MB/s (bad) Could it be disk performance issue? Test2: Physical box is running ntttcpr.exe -a 6 -m 6,0,VM_IP_ADDRESS VM is running ntttcps.exe -a 6 -m 6,0,PHY_BOX_IP_ADDRESS Transfer speed (as observed by Windows Task Manager on both machines): ~11MB/s (bad) Could it be switch performance issue? Test3: physical box is running vSphere Client I open Summary Storage datastore Browse Datastore... from physical box and upload a file to datastore Transfer speed (as observed by Windows Task Manager on physical box): ~26-36MB/s (good) Could it be a vm specific issue? Test4: Installed ntttcp to another vm on the same esx server Measured network performance between vms on the same esx server with NTttcp Transfer speed (as observed by Windows Task Manager on physical box): ~90-120MB/s (excellent :) Test5: I have another esx server on the same site, connecting to the same datastore and same switch. Those two ESX servers have both 2 NICs. One NIC goes to switch while the other goes directly to the other ESX server. vMotioned one of the testing vms off to the other ESX host Measured network performance between vms on different esx servers with NTttcp Transfer speed (as observed by Windows Task Manager on physical box): ~11MB/s (bad) While I'm aware of these: ESXi 4.1 slow file transfer ESXi 5 network performance is slow Debian Etch and ESXi slow network speeds VMWare ESXi slow file copy to guest they did not help (or I must have been missed something)

    Read the article

  • Server 2003 PDC DNS not working..Failover server is...

    - by Seth
    In the midst of trying to utilize proc power, i create a fault tolerant DNS server a while ago. Since, Ive been trying to add another controller for exchange. So I thought I would revert back to a single primary DNS for the meantime and now Im balancing on a thread. The server i thought I uninstalled DNS, is still acting as DNS. And now the PDC does not resolve. Can anybody walk me through, Im overwhelmed and cant think straight... Im afraid if anyone restarts their machine they wont have internet. Update Ok so from the beginning. I was configuring Exchange on a new server 2008. How it happened I dont know, but it started to not resolve DNS. (exclamation mark on NIC) even though everything was static. So ultimately I decided to remove the server from the problem, because I noticed DNS was in disarray if I used the DNS IP of the first server. This is when I tested with nslookup on each DNS server. I had uninstalled DNS from the second server, but nslookup was still resolving with that IPaddress, which has me all wound up cause I dont understand. So, since the first DNS server isn't resolving, Im assuming if the second one isnt configured right I'll loose internet. Im just confused and dont know where to start troubleshooting...

    Read the article

  • Windows Server 2012 Hyper-V very slow

    - by Matt Taylor
    I have been running several Hyper-V VMs on Windows Server 2008 R2 for the past couple of years and enjoying perfectly adequate performance for my testing/development/r&d environments. I'm a software developer so my hardware knowledge is basic however I built the rig using: •Gigabyte GA-X58A-UD3R Intel X58 (Socket 1366) DDR3 Motherboard •Intel Core i7 960 3.20GHz (Bloomfield) (Socket LGA1366) •24GB triple channel RAM The host OS is running on an OCZ SSD and all the VMs are running on a 2TB Marvell SATA3 RAID 0 array consisting of 2 Western Digital Caviar Black 7,200rpm drives. I have tested the speed of the 2TB drive and appear to be getting less than 3Mbs but it can adequately run a 4 VM farm including a DC, (SQL) database and IIS application servers. I recently upgraded the SSD on which the host runs to a 256GB OCZ Vertex 4 and took the opportunity to upgrade to Windows Server 2012 and installed the Hyper-V role. I tried importing one of my existing Windows Server 2008 R2 VMs (and converted it to .vhdx) plus I have tried creating a brand new Windows Server 2008 R2 VM but both are running extremely slowly and I can see nothing obvious using the host and guest Task Manager/Resource Monitor tools. In both cases the VM has 8GB RAM (fixed), 4 CPUs, fixed size HD (not expanding) and is using an external virtual network running on a separate NIC to the host. I have upgraded the BIOS to the latest available version and checked the virtualization settings. I have run out of "obvious" (to a developer) things to check/configure and my next option will be to re-install the host OS but before I do I would very much appreciate any advice from any experts out there. Thanks

    Read the article

  • Linux VLAN Bridge

    - by raspi
    I have home network with VLANs, one for LAN, one for WLAN and one for internet. I'd like to use bridging so that instead of configuring these same VLANs to every machine, they had own VLAN ID and bridges were LAN, WLAN and internet. I've tried it but for some reason keep-alive/ttl seems to get broken because SSH sessions etc suddenly disconnects. We have this same setup working in workplace for 4+ years with 100+ customers but it's custom firewall/router hardware so accessing it is impossible. I know that it runs Linux. So what is Debian/Ubuntu default network settings doing wrong or is it just NIC driver/hw problem? I've tried to mess araund with ttl etc settings without any luck. The bad stuff is happening in the bridge because current VLAN-only setup works fine. interfaces: auto lo iface lo inet loopback # The primary network interface allow-hotplug eth0 allow-hotplug eth1 iface eth0 inet static iface eth1 inet static auto vlan111 auto vlan222 auto vlan333 auto vlan444 auto br0 auto br1 auto br2 # LAN iface vlan111 inet static vlan_raw_device eth0 # WLAN iface vlan222 inet static vlan_raw_device eth0 # ADSL Modem iface vlan333 inet static vlan_raw_device eth1 # Internet iface vlan444 inet static vlan_raw_device eth0 # LAN bridge iface br0 inet static address 192.168.0.1 netmask 255.255.255.0 bridge_ports eth0.111 bridge_stp on # Internet bridge iface br1 inet static address x.x.x.x netmask x.x.x.x gateway x.x.x.x bridge_ports eth1.333 eth0.444 bridge_stp on post-up iptables -t nat -A POSTROUTING -o br1 -j MASQUERADE pre-down iptables -t nat -D POSTROUTING -o br1 -j MASQUERADE # WLAN bridge iface br2 inet static address 192.168.1.1 netmask 255.255.255.0 bridge_ports eth0.222 bridge_stp on Sysctl: net.ipv4.conf.default.forwarding=1

    Read the article

  • Virtualizing an Inline network appliance with VirtualBox (or VMWare)

    - by Tzury Bar Yochay
    My device, which is a Linux based IP in-liner is transparent to the network peripherals, that is, no IP address assigned to any of its interfaces. For the sake of the conversation, let's use ADSL connection as an example, while the device is inspecting the bi-directional traffic, the network is behaving same as if device was not there, attached to the wire (see Physical setup at the attached diagram). I wonder if I can enclosed that "device" within a Windows machine and have it operated virtually so it still seats inline between the ADSL router and the Windows netwroking interface by using virtual NICs, (or whatever their name is in windows), and inspecting the traffic, same as if it was on a separate physical device, the drawing under "Virtual Setup" in the attached diagram show what I am trying to achieve. Reading a bit on the VirtualBox docs, seems like binding the right side is relatively simple, perhaps I should have one network adapter set as Bridge Networking and VirtualBox will connect it to the physical NIC on the host machine, and network packets are exchanged directly, circumventing the host operating system's network stack (WinXP in my case). However, I have no idea how to achieve the left side of my diagram, which requires adding virtual NICs to windows and configure them correctly in a way to make that pipeline possible. I would appreciate any help. by the way, if that is not possible with VirtualBox but with other virtualization solution (e.g. VMWare), I would accept the other as well.

    Read the article

  • What file transfer protocols can be used for PXE booting besides TFTP?

    - by Stefan Lasiewski
    According to ISC's dhcpd manpage: The filename statement filename "filename"; The filename statement can be used to specify the name of the initial boot file which is to be loaded by a client. The filename should be a filename recognizable to whatever file transfer protocol the client can be expected to use to load the file. My questions are: What file transfer protocols, besides tftp, are available to load the file (e.g. What protocols "can be expected to" load the file)? How can I tell? Can I see a list of these protocols? Does my choice of DHCP server influence which file transfer protocols are in use? Pretend I want to use dnsmasq instead of ISC's dhcpd Are these features dependent on the PXE which is in use (e.g. My Intel NICs use an Intel ROM)? I know that some PXE-variants, such as iPXE/gPXE/Etherboot, can also load files over HTTP. However, the PXE rom needs to be replaced with the iPXE image, either by chainloading or by burning the PXE rom onto the NIC. For example, the iPXE Howto "Using ISC dhcpd" says: ISC dhcpd is configured using the file /etc/dhcpd.conf. You can instruct iPXE to boot using the filename directive: filename "pxelinux.0"; or filename "http://boot.ipxe.org/demo/boot.php";

    Read the article

  • Linux server: Dropped packets

    - by Lars
    I see dropped packets using ifconfig on my eth0 interface: eth0 Link encap:Ethernet HWaddr 00:15:17:0d:03:ca inet addr:10.0.1.2 Bcast:10.0.1.255 Mask:255.255.255.0 UP BROADCAST RUNNING MULTICAST MTU:9000 Metric:1 RX packets:30268348 errors:0 dropped:70721 overruns:0 frame:0 TX packets:133076885 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:8699434077 (8.6 GB) TX bytes:194937313025 (194.9 GB) Interrupt:16 Memory:feae0000-feb00000 When i use ethtool -S i dont see anything wrong: NIC statistics: rx_packets: 30267138 tx_packets: 133074510 rx_bytes: 8699356158 tx_bytes: 194934147340 rx_broadcast: 35296 tx_broadcast: 5435 rx_multicast: 0 tx_multicast: 0 rx_errors: 0 tx_errors: 0 tx_dropped: 0 multicast: 0 collisions: 0 rx_length_errors: 0 rx_over_errors: 0 rx_crc_errors: 0 rx_frame_errors: 0 rx_no_buffer_count: 0 rx_missed_errors: 0 tx_aborted_errors: 0 tx_carrier_errors: 0 tx_fifo_errors: 0 tx_heartbeat_errors: 0 tx_window_errors: 0 tx_abort_late_coll: 0 tx_deferred_ok: 0 tx_single_coll_ok: 0 tx_multi_coll_ok: 0 tx_timeout_count: 0 tx_restart_queue: 0 rx_long_length_errors: 0 rx_short_length_errors: 0 rx_align_errors: 0 tx_tcp_seg_good: 5757001 tx_tcp_seg_failed: 0 rx_flow_control_xon: 8649 rx_flow_control_xoff: 62072 tx_flow_control_xon: 0 tx_flow_control_xoff: 0 rx_long_byte_count: 8699356158 rx_csum_offload_good: 30212111 rx_csum_offload_errors: 0 rx_header_split: 10857552 alloc_rx_buff_failed: 0 tx_smbus: 0 rx_smbus: 0 dropped_smbus: 0 rx_dma_failed: 0 tx_dma_failed: 0 I am running Ubuntu 12.04 with kernel 3.2.0-30-generic #48-Ubuntu SMP I have pinged every device on my internal network for about 24 hours, without packet loss. Also checked my router and my interface to the WAN, also no errors there. Does anyone have any clue?

    Read the article

  • debian 6 losing a large amount of packets

    - by Sc0rian
    I have a rather strange problem. We covered all the obvious hardware related issues (different nic, eth cable and switch) however I cannot seem to stop eth dropping packets. I have 4 servers all exactly the same. driver: e1000e version: 1.2.20-k2 firmware-version: 1.8-0 bus-info: 0000:06:00.0 They are all running the latest kernel(2.6.32-5-amd64). However they do this: RX packets:17073870634 errors:0 dropped:14147208 overruns:0 frame:0 another server: eth0 Link encap:Ethernet HWaddr e0:69:95:05:2f:cb inet addr:10.10.10.86 Bcast:10.10.10.255 Mask:255.255.255.0 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:5455209277 errors:0 dropped:375445 overruns:0 frame:0 TX packets:3666134366 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:6688414486673 (6.0 TiB) TX bytes:1611812171539 (1.4 TiB) Interrupt:20 Memory:d0600000-d0620000 eth1 Link encap:Ethernet HWaddr 00:1b:21:b7:7a:ce inet addr:10.10.0.86 Bcast:10.10.0.255 Mask:255.255.255.0 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:15473695728 errors:0 dropped:5808325 overruns:0 frame:0 TX packets:20112364421 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:9192378766434 (8.3 TiB) TX bytes:20216368266761 (18.3 TiB) Interrupt:17 Memory:d0280000-d02a0000 A massive amount of dropped packets. I have tried to load on the latest driver, 1.9.5. This did nothing. I'm not sure what else to do.

    Read the article

  • Window Server 2003 Print spooler

    - by mikenardone
    Hello Everyone in ServerFault, I am new to this website. I have been coming here to fix my own problems. I believe everyone here on this website is great. I could not find this issue anywhere. I am sure that other people had this issue. I have IBM X3850 48GB ram 2 TB of hard drives, four NIC cards. 2 Xeon 1.7 CPU. I am running VMware ESX. I believe that was the paid version if not then it is ESXI. I have 7 Servers on this server. All Window server 2003. On one of the Servers I keep on getting CPU is at 100% . So when I go into task manager and look at the processes that is going on, it is my print spooler. I have 30 different HP laserjet printers and two copiers from HP. I believe it is an driver issue, but I can't figure with one is doing this. Is there any programs for window server 2003 that finds bad print drivers.

    Read the article

  • Asus PCE-N53 11n N600 PCI-E Adapter on 3.x kernel

    - by CITguy
    Problem ASUS PCE-N53 wireless NIC doesn't work for latest versions of the linux kernel. How do I get it working on my system? (Note: I'm posting the answer I've found for others to use.) Installing Driver for Linux 3.x Kernel ASUS provides Linux drivers from their website, but it mentions that the driver supports "Linux Kernel 2.6.x", so it won't work without a some modifications to the driver code. Fortunately, an archlinux forum mentions similar problems and one user was able to create a patch for kernel 3.8.x that seems to work with kernel 3.11.x. Here's how I got it working: Prerequisites Ubuntu: sudo apt-get install build-essential Arch: sudo pacman -S base-devel Steps: 1. Download the driver from the ASUS website The download can be found under "Support Drivers & Tools". 2. Unzip the contents of the downloaded file cd into the new directory 3. Patch The arch forum mentions a 3.8 patch file that needs to be downloaded. Download rt5592sta_fix_64bit_3.8.patch to the current directory. tar -xvf {driver_source.tar.gz} cd into the directory created in previous step patch -p1 < ../rt5592sta_fix_64bit_3.8.patch 4. Compile NOTE: You will need to use sudo for it to compile properly. sudo make sudo make install sudo modprobe rt5592sta 5. Enjoy If all is well, you should now have a working card.

    Read the article

  • SQL Server 2005 SE SP3 on Windows Server 2008 R2 x64 premature query disconnections

    - by southernpost
    New Dell PowerEdge R910, 4x8 Intel X7560, 192GB RAM, hardware NUMA, local RAID, Broadcom NetExtreme II multiport NIC, unteamed, TCP Offload disabled, RSS disabled, NetDMA disabled, Hyperthreading disabled. SQL Server 2005 SE x64 SP3 on Windows Server 2008 R2 EE x64. No other apps on server. Max Mem = 180GB, Max DOP = 4. Existing Windows Server 2003 R2 EE x64 app server connecting to Dell via firewall using SQL Authenticated logins. Symptoms: Intermittent errors at the app server: A transport-level error has occurred when sending the request to the server. (provider: TCP Provider, error: 0 - An existing connection was forcibly closed by the remote host.) Findings: Running queries from SSMS located on another machine within the same domain as the SQL Server run without error. SQLIO showed good performance. Windows and SQL logs show no related messages. Microsoft reveiwed PssDiag trace and stated that "We are not seeing timeouts from SQL Side. The queries bring run against the database are timing out within 9secs. This is a database connectivity error." "we can also see from the AttnSeq column that we are also not seeing any Attentions from the SQL Side.". Dell has confirmed that we are using the latest Broadcom drivers.

    Read the article

  • Strange RDP / Remote Desktop problem

    - by John Landheer
    I'll try to be as specific as I can be: Server is running SBS 2008 R2 (with all updates) Server is connected to the internet Server has 2 NIC's, one is disabled Server is running RDP Service (accessible directly from the internet, I know, not as secure as it should be) Computers A and B are on the same local net. Computers A and B are both Windows 7. Users X and Y are both admins on the server Computer A can connect as user X to the server with mstsc Computer A can connect as user Y to the server with mstsc Computer B can connect as user X to the server with mstsc Computer B CANNOT connect as user Y to the server with mstsc! Error that username/password is incorrect. The last point is the problem, I get an authentication error. This used to work flawlessly for the last year. The server and desktops have been rebooted. EDIT: I tried: prefixing domain to the username prefixing the server computer name to the username change the password copy/paste the password from notepad to make sure it was correct I find it very strange.... EDIT: The computers are not on the same subnet as the server. The server is at my hosting provider. All computers as all users can reach the web app that is running on the server.

    Read the article

  • C# sends SQL data 4 times less from one box than from another

    - by Bobb
    W2003, .NET 3.5, SQL 2008 I have prod and UAT app servers deployed in 2 different data centres. I have a C# app which reads text file, parse the text and sends the data to the SQL in bulk. SQL server is in US and the app servers are in London (but in different places). All POPs have dedicated network connections. There is no public internet involved. When the app runs on UAT server I can see in Perfmon that the Send byte/sec is x4 higher than from production server. My estimate is that one server outputs at 1 MB/s and the other at 250 KB/s rate. My suspicion immediately is that there is a router on one of the DCs which shapes traffic or does QoS limitation on traffice from London to US. However support and Windows team and networkig team all are saying that there are no differences in neither networking config on the 2 DCs nor NIC config on the 2 app server... How to find out why is the networking bottlneck is 4 times tighter in one place than in the other? What can I do about it?

    Read the article

  • IP routing Solaris 9 access the internet from local network

    - by help_me
    I am trying to configure the NICS on the Solaris Sparc server. My problem lies in getting out to the "Internet" from the local network. I have requested the NIC to receive a DHCP server address #ifconfig -interface dhcp start. If anyone could guide me as to what I need to do next. I am not able to ping 4.2.2.2 or access the internet. Much appreciated, thank you #uname -a SunOS dev 5.9 Generic_122300-59 sun4u sparc SUNW,Sun-Fire-V210 ifconfig -a lo0: flags=1000849<UP,LOOPBACK,RUNNING,MULTICAST,IPv4> mtu 8232 index 1 inet 127.0.0.1 netmask ff000000 bge0: flags=1000843<UP,BROADCAST,RUNNING,MULTICAST,IPv4> mtu 1500 index 2 inet 10.100.0.3 netmask ffffc000 broadcast 10.100.63.255 bge0:2: flags=1000843<UP,BROADCAST,RUNNING,MULTICAST,IPv4> mtu 1500 index 2 inet 10.100.0.22 netmask ffffc000 broadcast 10.100.63.255 bge3: flags=1004843<UP,BROADCAST,RUNNING,MULTICAST,DHCP,IPv4> mtu 1500 index 12 inet 169.14.60.37 netmask fffffe00 broadcast 169.14.61.255 cat /etc/defaultrouter 10.100.0.254 169.14.60.1 cat /etc/resolv.conf nameserver 169.14.96.73 nameserver 169.10.8.4 netstat -rn Routing Table: IPv4 Destination Gateway Flags Ref Use Interface -------------------- -------------------- ----- ----- ------ --------- 169.14.60.37 169.14.60.1 UGH 1 0 169.14.60.0 169.14.60.37 U 1 18 bge3 10.100.0.0 10.100.0.3 U 1 34940 bge0 10.100.0.0 10.100.0.22 U 1 0 bge0:2 224.0.0.0 10.100.0.3 U 1 0 bge0 default 10.100.0.254 UG 1 111 default 169.14.60.1 UG 1 26 127.0.0.1 127.0.0.1 UH 10 59464 lo0 bash-2.05$ sudo ndd -get /dev/ip bge0:ip_forwarding 1 bash-2.05$ sudo ndd -get /dev/ip bge3:ip_forwarding 1 bash-2.05$ sudo ndd -get /dev/ip ip_forwarding 1

    Read the article

< Previous Page | 35 36 37 38 39 40 41 42 43 44 45  | Next Page >