Search Results

Search found 1733 results on 70 pages for 'shutdown'.

Page 39/70 | < Previous Page | 35 36 37 38 39 40 41 42 43 44 45 46  | Next Page >

  • SQL Server crashes when remote query fails

    - by Hemanshu Bhojak
    Setup: I have a linked server setup on SQL Server 2005 which is pointing to an Oracle DB. The linked server has RPC enabled. Problem: When a query throws an exception on the remote server (Oracle DB) the SQL Server instance crashes. The logs say that the crash was due to some problem with the RPC call. Is there a way in which I can prevent the entire server to collapse but also use RPC over my linked server. EDIT: Event Log SQL Server is terminating because of fatal exception c0000005. This error may be caused by an unhandled Win32 or C++ exception, or by an access violation encountered during exception handling. Check the SQL error log for any related stack dumps or messages. This exception forces SQL Server to shutdown. To recover from this error, restart the server (unless SQLAgent is configured to auto restart). For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp.

    Read the article

  • Assistance in setting up new APC Smart-UPS RT on a new VMware enviroment

    - by user38085
    I'm new to the realm of setting up a APC Smart-UPS RT 8000VA UPS with a management network card (AP9618). The project calls for the upgrade of the firmware for the network card to the newest and greatest. It also calls for the Powerchute Business Software to be installed with notifications setup per email for temperature, shutdown, and battery low. I know I'll have to use the serial cable to flash the firmware and install the software on one server 2003 box. Also on that server I'll have to install the software and setup the GUI (IP address) interface. Whats confusing the most is the whole process, and steps to use without taking down the network, which would be very bad. In flashing the firmware does it take down the UPS? Do i have to run BOOTP commands to setup the network card? Also no agents will be used on any of the VWware OS's and no SNMP trap will be used.

    Read the article

  • How to enable "Sleep" for Windows 2012 server

    - by Ramesh
    I recently installed Windows Server 2012. This will serve as the dev-instance for our engineers and will be accessed in multiple time zones. I therefore plan to run this 24x7 but want to conserve energy by going to sleep mode when not in use & enable Wake-On-Magic-Packet. Based on the previous post it appears that there is no option to sleep Win Server 2012 with Hyper-V. Since I don't care much about virtualization now, I uninstalled Hyper-V. In addition to this, I have done the following 1) Ran powercfg -a. Don't find sleep. 2) Added [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\hvboot] "Start"=dword:00000003 to try gaining sleep - no luck! 3) Only see Shutdown and Restart in power options. Please help me sleep and save the planet :-) Thanks, Ramesh

    Read the article

  • Centos Xen resizing DomU partition and volume group

    - by thepearson
    I have a setup like so: Dom0 LV | DomU Physical Disk | | XVDA1 XVDA2 (/boot) (DomU PV) | VolGroup00 (DomU VG) | | LogVol00 LogVol01 (swap) (/) I am trying to resize the DomU root Filesystem. (VolGroup00-LogVol01) I realize that I now need to resize the partition XVDA2, however when I try doing this with parted on Dom0 it just tells me "Error: Could not detect file system." So to resize the root part VolGroup-LogVol00 shouldn't the process be: # Shut down DomU xm shutdown domU #Resize Dom0 Logical volume lvextend -L+2G /dev/volumes/domU-vol # Parted parted /dev/volumes/domU-vol # Resize root partition resize 2 START END (This is where I get an error) "Error: Could not detect file system." # add the vm volume group to Dom0 lvm kpartx -a /dev/volumes/domU-vol # resize the domU PV pvresize /dev/mapper/domU-pl (as listed in pvdisplay) # The domU volume group should automatically adjust # resize the DomU lv lvextend -L+2G /dev/VolGroup/LogVol00 And then obviously increase the fs, remove the device from kpartx etc The problem is I dont know how to resize the partition? How do I resize this partition so I can run pvresize on the DomU? Thanks

    Read the article

  • The User Profile Service

    - by Daryl Gill
    I tried logging into my computer after an "ungraceful" shutdown due to a power cut.. I got prompted with a message stating the user profile service failed the login. After reading a k/b on Microsoft I managed to re-login to the "corrupt" account by making registery edits.. But the next step (After having the ability to logon) is a major concern for me.. Would the guys at superuser suggest: 1) Carry on using said account 2) Re-install Windows to eliminate the possible chance of a reoccouring problem 3) Migrate all user data over to a new account and with that being said above. I had to issue the command line: net user administrator /active:yes to activate the hidden adminstrator account, would it be recommended/secure to disable the account or leave it active?

    Read the article

  • Cannot install .NET Framework 4.0 on Windows XP SP3

    - by Bob
    I'm using Windows XP SP3 logged in as the administrator. I had RAID Mirroring running. The motherboard broke earlier in the year. When I got a new battery I did not resync. I just use the disks as two separate disks. I searched Google for the errors but I didn't find anything detailed enough. The following Microsoft components are in Add/Remove programs: .NET Framework 1.1 .NET Framework 2.0 Service Pack 2 .NET Framework 3.0 Service Pack 2 .NET Framework 3.5 SP1 Microsoft Compression Client Pack 1.0 for Windows XP Microsoft Office Enterprise 2007 Microsoft Silverlight Microsoft USB Flash Driver Manager Micrsoft User-mode Driver Framework Feature Pack 1.0 Microsoft Visual C++ 2005 ATL Update KB 973923 x86 8.050727.4053 Microsoft Visual C++ 2005 Redistributable This is the installation log: Exists: evaluating... [10/21/2011, 22:17:14]MsiGetProductInfo with product code {3C3901C5-3455-3E0A-A214-0B093A5070A6} found no matches [10/21/2011, 22:17:14] Exists evaluated to false [10/21/2011, 22:15:50]calling PerformAction on an installing performer [10/21/2011, 22:15:50] Action: Performing actions on all Items... [10/21/2011, 22:15:50]Wait for Item (clr_optimization_v2.0.50727_32) to be available [10/21/2011, 22:15:50]clr_optimization_v2.0.50727_32 is now available to install [10/21/2011, 22:15:50]Creating new Performer for ServiceControl item [10/21/2011, 22:15:50] Action: ServiceControl - Stop clr_optimization_v2.0.50727_32... [10/21/2011, 22:15:50]ServiceControl operation succeeded! [10/21/2011, 22:15:50] Action complete [10/21/2011, 22:15:50]Error 0 is mapped to Custom Error: [10/21/2011, 22:15:50]Wait for Item (Windows6.0-KB956250-v6001-x86.msu) to be available [10/21/2011, 22:15:51]Windows6.0-KB956250-v6001-x86.msu is now available to install [10/21/2011, 22:15:51]Created new DoNothingPerformer for File item [10/21/2011, 22:15:51]No CustomError defined for this item. [10/21/2011, 22:15:51]Wait for Item (Windows6.1-KB958488-v6001-x86.msu) to be available [10/21/2011, 22:15:51]Windows6.1-KB958488-v6001-x86.msu is now available to install [10/21/2011, 22:15:51]Created new DoNothingPerformer for File item [10/21/2011, 22:15:51]No CustomError defined for this item. [10/21/2011, 22:15:51]Wait for Item (netfx_Core.mzz) to be available [10/21/2011, 22:15:52]netfx_Core.mzz is now available to install [10/21/2011, 22:15:52]Created new DoNothingPerformer for File item [10/21/2011, 22:15:52]No CustomError defined for this item. [10/21/2011, 22:15:52]Wait for Item (netfx_Core_x86.msi) to be available [10/21/2011, 22:15:52]netfx_Core_x86.msi is now available to install [10/21/2011, 22:15:52]Creating new Performer for MSI item [10/21/2011, 22:15:52] Action: Performing Action on MSI at F:\DOCUME~1\Owner\LOCALS~1\Temp\Microsoft .NET Framework 4 Client Profile Setup_4.0.30319\netfx_Core_x86.msi... [10/21/2011, 22:15:52]Log File F:\DOCUME~1\Owner\LOCALS~1\Temp\Microsoft .NET Framework 4 Client Profile Setup_20111021_221545515-MSI_netfx_Core_x86.msi.txt does not yet exist but may do at Watson upload time [10/21/2011, 22:15:52]Calling MsiInstallProduct(F:\DOCUME~1\Owner\LOCALS~1\Temp\Microsoft .NET Framework 4 Client Profile Setup_4.0.30319\netfx_Core_x86.msi, EXTUI=1 [10/21/2011, 22:17:14]MSI (F:\DOCUME~1\Owner\LOCALS~1\Temp\Microsoft .NET Framework 4 Client Profile Setup_4.0.30319\netfx_Core_x86.msi) Installation failed. Msi Log: Microsoft .NET Framework 4 Client Profile Setup_20111021_221545515-MSI_netfx_Core_x86.msi.txt [10/21/2011, 22:17:14]PerformOperation returned 1603 (translates to HRESULT = 0x80070643) [10/21/2011, 22:17:14] Action complete [10/21/2011, 22:17:14]OnFailureBehavior for this item is to Rollback. [10/21/2011, 22:17:14] Action: Performing actions on all Items... [10/21/2011, 22:17:14] Action complete [10/21/2011, 22:17:14] Action complete [10/21/2011, 22:17:14]Final Result: Installation failed with error code: (0x80070643), "Fatal error during installation. " (Elapsed time: 0 00:01:29). [10/21/2011, 22:17:41]WM_ACTIVATEAPP: Focus stealer's windows WAS visible, NOT taking back focus SECOND LOG REQUESTED BELOW: MSI (s) (6C:EC) [22:17:13:828]: Invoking remote custom action. DLL: F:\WINDOWS\Installer\MSIBB4.tmp, Entrypoint: NgenUpdateHighestVersionRollback MSI (s) (6C:64) [22:17:13:984]: Executing op: ActionStart(Name=CA_NgenRemoveNicPFROs_I_DEF_x86.3643236F_FC70_11D3_A536_0090278A1BB8,,) MSI (s) (6C:64) [22:17:13:984]: Executing op: ActionStart(Name=CA_NgenRemoveNicPFROs_I_RB_x86.3643236F_FC70_11D3_A536_0090278A1BB8,,) MSI (s) (6C:64) [22:17:13:984]: Executing op: CustomActionRollback(Action=CA_NgenRemoveNicPFROs_I_RB_x86.3643236F_FC70_11D3_A536_0090278A1BB8,ActionType=17729,Source=BinaryData,Target=NgenRemoveNicPFROs,) MSI (s) (6C:AC) [22:17:13:984]: Invoking remote custom action. DLL: F:\WINDOWS\Installer\MSIBB5.tmp, Entrypoint: NgenRemoveNicPFROs MSI (s) (6C:64) [22:17:14:000]: Executing op: End(Checksum=0,ProgressTotalHDWord=0,ProgressTotalLDWord=0) MSI (s) (6C:64) [22:17:14:000]: Error in rollback skipped. Return: 5 MSI (s) (6C:64) [22:17:14:015]: No System Restore sequence number for this installation. MSI (s) (6C:64) [22:17:14:015]: Unlocking Server MSI (s) (6C:64) [22:17:14:015]: PROPERTY CHANGE: Deleting UpdateStarted property. Its current value is '1'. MSI (s) (6C:64) [22:17:14:031]: Note: 1: 1708 MSI (s) (6C:64) [22:17:14:031]: Product: Microsoft .NET Framework 4 Client Profile -- Installation failed. MSI (s) (6C:64) [22:17:14:078]: Cleaning up uninstalled install packages, if any exist MSI (s) (6C:64) [22:17:14:078]: MainEngineThread is returning 1603 MSI (s) (6C:EC) [22:17:14:171]: Destroying RemoteAPI object. MSI (s) (6C:9C) [22:17:14:171]: Custom Action Manager thread ending. MSI (c) (F4:C4) [22:17:14:203]: Decrementing counter to disable shutdown. If counter >= 0, shutdown will be denied. Counter after decrement: -1 MSI (c) (F4:C4) [22:17:14:203]: MainEngineThread is returning 1603 === Verbose logging stopped: 10/21/2011 22:17:14 ===

    Read the article

  • network issue ubuntu 8.04 in vmware esx

    - by hoberion
    ok, this is really pissing me off I have one ubuntu 8.04 instance running on vmware (esx) which decided after a reboot to stop resolving dns requests, I also cant connect to it using ssh although I can ping the server and its really that server (when I shutdown the server the ping also stops) stuff I tried: - reboot again :) - nslookup - serverip - setting networking to dhcp - offering some cute kittens to lucifer - removing the virtual nic and adding another (to get a different mac) - migrating the instance to another esx host - drinking 20 cups of espresso - stopped all services - running dnsmasq on another server and connecting to that dns - tcpdumping - disabling ip6 symptoms: cant resolve anything nslookup just says "no servers found..." although I can ping the servers traceroute to gateway doesnt work (even with traceroute -4 -n gatewayip) collegues laughing at me any thoughts

    Read the article

  • Im getting the "Console Window Host has stopped working" popup in a few places.

    - by m1sk
    Im running Windows 7 on a 17 inch Macbook Pro, late 2011. Last Saturday I opened my laptop(It was either asleep or shutdown before hand) and suddenly had a whole bunch of problem. First off I got a few of pop-errors, my macbook was out of battery. I also had problems with my trackpad(no scrolling or right-click), which I fixed by reinstalling bootcamp. Now a days when ever I run cmd I get the popup Console Window Host has stopped working If I chose the Close the program I get another popup The application was unable to start correctly (0xc0000142) Click OK to close the application. This doesnt happen just with cmd if un/install a program I get similar popups(first one). And in some other case like in visual studio when i was working on class work.

    Read the article

  • Problem restarting my Ubuntu system

    - by VoY
    Whenever I try to restart my Ubuntu either from the command line by typing reboot or in GNOME the computer goes from X to console, starts the shutdown process and then a message saying "[ some number ] Starting new kernel" appears on the screen and the computer goes back to X login screen. I suspect this must have something to do with nvidia drivers, because it seemed to have appeared around the time I bought a new graphic card. Also, when I reboot the second time I see weird graphical artifacts on the screen. When I boot from ubuntu live cd I can reboot just fine. I used jaunty, recently I switched to karmic with no change. This bug is very annoying, because I have to hard reset my computer in order to reboot. Also not good for the filesystems, I suspect. Can you suggest a way to debug the cause or if not at least the easiest way to go about reinstalling ubuntu without losing customizations/settings/data?

    Read the article

  • Kernel Panic - Not Syncing: Fatal exception

    - by user3513346
    Server (HP Proliant D320e G8 v2) froze at this screen during boot today (running CentOS 6.5): I was able to get the server to boot after a 'press and hold'. I've been having many problems with the server lately - mainly related to the iLO and being unable to install CentOS 7. Could someone please help me decode this screen? Does it suggest there could be a serious problem? Or does this just happen sometimes? It is possible that the OS wasn't 'shutdown' properly before the failed boot.

    Read the article

  • Dynamips Virtual Router not pinging external host after bridging

    - by maiky
    I have setup a virtual router image with dynamips and setup bridging between tap0 interface of the virtual router and eth0 and br0 with commands [root@cisco_host]# brctl addbr br0 [root@cisco_host]# ifconfig br0 up [root@cisco_host]# ifconfig eth1 0.0.0.0 [root@cisco_host]# brctl addif br0 eth1 [root@cisco_host]# ifconfig br0 192.168.0.100 netmask 255.255.255.0 up In dynagen configuration I have: f0/0 = NIO_tap:tap0 So, [root@cisco_host]# brctl addif br0 tap0 [root@cisco_host]# ifconfig tap0 up router(config)#int fa0/0 router(config-if)#ip address 192.168.0.101 255.255.255.0 router(config-if)#no shutdown After the configuration above I was expecting that from inside the router I could ping an external machine with IP 192.168.0.1 Actually from the host I can ping the external host 192.168.0.1 as well as 192.168.0.100 and 192.168.0.101. So what am I missing here? tap0 is bridged with br0 and in turn with eth1. So why the router is not pingable from 192.168.0.1 and vice-versa??

    Read the article

  • Windows 2003 Cluster: Failover Delay

    - by Ramon Marco Navarro
    I am testing the failover policies of our test failover cluster system. When I shutdown the node who is currently controlling the cluster (NODE1), it takes about 2 mins and 40 seconds before the next node on the preferred list (NODE2) takes control of the cluster. I tried changing the looksAlive and isAlive interval to 5000ms to all resources, but that didn't help. Looking at the Event Viewer of the remaining nodes, it shows that it was almost instantly detected that NODE1 was down. But it took another ~2:40 minutes for it to be removed from the live cluster list and for NODE2 to take over. Is there anyway of changing or shortening this "failover delay"? This is the setup of the cluster: (1) One ClusterDC connected to the public network (3) Three nodes running Win2003 with a quorum type of MNS Private network is connected to network hub ________________ _________________ (ClusterDC)=------=| |=------=(Node1)=------=| | |Public Network|=------=(Node2)=------=|Private Network| | (Switch) |=------=(Node3)=------=| (Hub) | ---------------- -----------------

    Read the article

  • Can't Shut Down computer with windows 8 Release Preview

    - by Bram Winda
    I downloaded Release Preview and installed it. I have a problem when I shut down the computer. After I press windows key + I Power Shut Down, a box pops up titled "Winlogon.exe - No Disk. Then under that is the message "There is no disk in the drive. Please insert a disk into Drive G". After hitting the retry button a couple of different times the screen finally goes dark. When I was going to turn it back on, I noticed the Power Button was still list. The only way to do a complete Shutdown is to hold in the power button directly. How do I fix this problem?

    Read the article

  • Why every change in Asus UX50v causes screen resolution get lost?

    - by Kaveh Shahbazian
    Why every change in Asus UX50v causes screen resolution get lost? Installing a new application, connecting to another wireless network, change some settings, ... causes this problem. For example after installing an application, UX50v needs to restart. And when it got restarted, resolution would be set to 640x480(or 600x800) and Hibernate and Sleep options are disappeared from shutdown menu! (I have other problems with this Asus UX50v crap too - like I can't update windows 7 because it crashes on Asus UX50v crap - but this one is absolutely ridiculous and stupid!)

    Read the article

  • How to get rid of resume information on ubuntu 9.10 ("karmic")

    - by Glen S. Dalton
    I am on an old laptop with Ubuntu 9.10 installed. I once tried to not shutdown but go into one of the resume states. On the next power on, resume did not work, but there was an error message during boot asking me for the resume image (which I do not have or know of) and when I press enter the normal boot happens. But this error pops up on every boot now. How can I get back the behaviour from before? Why does the boot process guess there would be a resume image and can I delete this information? I would like to post here the error messages from the boot proces, but they are not in /var/log/syslog, where else can they be?

    Read the article

  • CUPS basic auth error through web interface

    - by Inaimathi
    I'm trying to configure CUPS to allow remote administration through the web interface. There's enough documentation out there that I can figure out what to change in my cupsd.conf (changing Listen localhost:631 to Port 631, and adding Allow @LOCAL to the /, /admin and /admin/conf sections). I'm now at the point where I can see the CUPS interface from another machine on the same network. The trouble is, when I try to Add Printer, I'm asked for a username and password, but my response is rejected even when I know I've gotten it right (I assume it's asking for the username and password of someone in the lpadmin group on the server machine; I've sshed in with credentials its rejecting, and the user I'm using has been added to the lpadmin group). If I disable auth outright, by changing DefaultAuthType Basic to DefaultAuthType None, I get an "Unauthorized" error instead of a password request when I try to Add Printer. What am I doing wrong? Is there a way of letting users from the local network to administer the print server through the CUPS web interface? EDIT: By request, my complete cupsd.conf (spoiler: minimally edited default config file that comes with the edition of CUPS from the Debian wheezy repos): LogLevel warn MaxLogSize 0 SystemGroup lpadmin Port 631 # Listen localhost:631 Listen /var/run/cups/cups.sock Browsing On BrowseOrder allow,deny BrowseAllow all BrowseLocalProtocols CUPS dnssd # DefaultAuthType Basic DefaultAuthType None WebInterface Yes <Location /> Order allow,deny Allow @LOCAL </Location> <Location /admin> Order allow,deny Allow @LOCAL </Location> <Location /admin/conf> AuthType Default Require user @SYSTEM Order allow,deny Allow @LOCAL </Location> # Set the default printer/job policies... <Policy default> # Job/subscription privacy... JobPrivateAccess default JobPrivateValues default SubscriptionPrivateAccess default SubscriptionPrivateValues default # Job-related operations must be done by the owner or an administrator... <Limit Create-Job Print-Job Print-URI Validate-Job> Order deny,allow </Limit> <Limit Send-Document Send-URI Hold-Job Release-Job Restart-Job Purge-Jobs Set-Job-Attributes Create-Job-Subscription Renew-Subscription Cancel-Subscription Get-Notifications Reprocess-Job Cancel-Current-Job Suspend-Current-Job Resume-Job Cancel-My-Jobs Close-Job CUPS-Move-Job CUPS-Get-Document> Require user @OWNER @SYSTEM Order deny,allow </Limit> # All administration operations require an administrator to authenticate... <Limit CUPS-Add-Modify-Printer CUPS-Delete-Printer CUPS-Add-Modify-Class CUPS-Delete-Class CUPS-Set-Default CUPS-Get-Devices> AuthType Default Require user @SYSTEM Order deny,allow </Limit> # All printer operations require a printer operator to authenticate... <Limit Pause-Printer Resume-Printer Enable-Printer Disable-Printer Pause-Printer-After-Current-Job Hold-New-Jobs Release-Held-New-Jobs Deactivate-Printer Activate-Printer Restart-Printer Shutdown-Printer Startup-Printer Promote-Job Schedule-Job-After Cancel-Jobs CUPS-Accept-Jobs CUPS-Reject-Jobs> AuthType Default Require user @SYSTEM Order deny,allow </Limit> # Only the owner or an administrator can cancel or authenticate a job... <Limit Cancel-Job CUPS-Authenticate-Job> Require user @OWNER @SYSTEM Order deny,allow </Limit> <Limit All> Order deny,allow </Limit> </Policy> # Set the authenticated printer/job policies... <Policy authenticated> # Job/subscription privacy... JobPrivateAccess default JobPrivateValues default SubscriptionPrivateAccess default SubscriptionPrivateValues default # Job-related operations must be done by the owner or an administrator... <Limit Create-Job Print-Job Print-URI Validate-Job> AuthType Default Order deny,allow </Limit> <Limit Send-Document Send-URI Hold-Job Release-Job Restart-Job Purge-Jobs Set-Job-Attributes Create-Job-Subscription Renew-Subscription Cancel-Subscription Get-Notifications Reprocess-Job Cancel-Current-Job Suspend-Current-Job Resume-Job Cancel-My-Jobs Close-Job CUPS-Move-Job CUPS-Get-Document> AuthType Default Require user @OWNER @SYSTEM Order deny,allow </Limit> # All administration operations require an administrator to authenticate... <Limit CUPS-Add-Modify-Printer CUPS-Delete-Printer CUPS-Add-Modify-Class CUPS-Delete-Class CUPS-Set-Default> AuthType Default Require user @SYSTEM Order deny,allow </Limit> # All printer operations require a printer operator to authenticate... <Limit Pause-Printer Resume-Printer Enable-Printer Disable-Printer Pause-Printer-After-Current-Job Hold-New-Jobs Release-Held-New-Jobs Deactivate-Printer Activate-Printer Restart-Printer Shutdown-Printer Startup-Printer Promote-Job Schedule-Job-After Cancel-Jobs CUPS-Accept-Jobs CUPS-Reject-Jobs> AuthType Default Require user @SYSTEM Order deny,allow </Limit> # Only the owner or an administrator can cancel or authenticate a job... <Limit Cancel-Job CUPS-Authenticate-Job> AuthType Default Require user @OWNER @SYSTEM Order deny,allow </Limit> <Limit All> Order deny,allow </Limit> </Policy>

    Read the article

  • MSSQL instance shuts down

    - by citronas
    I'm currently developing a new ASP.net project hosted on a Windows Server 2008 RC2 with an MSSQL 2008 Express Database. I have three SQL instances (for different purposes) running which currently all contain a single database. For apprently no reason, these instances tend to shut down after some days, for no apparent reason. There might be low or none traffic to these instances, because there might be some days in a row, where I can't develop. It now occured several times, that one or two of these three instances just shut down, so that I can't access the database, without manually starting the instance. I can't seem to find a event log entry for the shutdown, which is most likely because I just enabled logging (why is the default setting off?) So the questions are: * Why does a SQL instance shut down? (Is there such thing as a "Shut down instance after 3 days of inactivity"? * How can I achieve that the instances are running 24/7?

    Read the article

  • INNODB mysql. Plugin disabled

    - by alexcunn
    When I startup mysql on my unbuntu server I will get a message. 121122 17:39:37 [Note] Plugin 'FEDERATED' is disabled. 121122 17:39:37 InnoDB: The InnoDB memory heap is disabled 121122 17:39:37 InnoDB: Mutexes and rw_locks use GCC atomic builtins 121122 17:39:37 InnoDB: Compressed tables use zlib 1.2.3.4 121122 17:39:37 InnoDB: Initializing buffer pool, size = 128.0M InnoDB: mmap(137363456 bytes) failed; errno 12 121122 17:39:37 InnoDB: Completed initialization of buffer pool 121122 17:39:37 InnoDB: Fatal error: cannot allocate memory for the buffer pool 121122 17:39:37 [ERROR] Plugin 'InnoDB' init function returned error. 121122 17:39:37 [ERROR] Plugin 'InnoDB' registration as a STORAGE ENGINE failed. 121122 17:39:37 [ERROR] Unknown/unsupported storage engine: InnoDB 121122 17:39:37 [ERROR] Aborting 121122 17:39:37 [Note] mysqld: Shutdown complete a few times I have got a message saying that the plugin is disabled. I use webmin to configure it. Could that be a problem?

    Read the article

  • Auto-Attach EBS-volume to a New Spot Instance?

    - by Jeff
    I am experimenting with EC2 spot instances, and am needing some data to be retained between terminations. Now as I understand it, when the current price goes above my max. bid, it will be automatically terminated. I assume any init scripts I have will be run on shutdown so I can push data off to the EBS before unmounting. My question is, how can I automatically mount the same EBS volume on the new spot instance once the price goes down, since it won't have any of my init scripts that I would've loaded onto the root volume the first time? Do I have to create a custom AMI, or is there some other way to achieve this?

    Read the article

  • X locks up with konqueror on comics.com

    - by retracile
    If I browse to comics.com using konqueror under KDE on Fedora 11, X will, after a delay, lock up. The mouse will move, but no keyboard input is recognized, and the screen does not react to the mouse passing over objects on screen. I am able to ssh into the machine and issue shutdown -r now and have that work. The machine is a Dell XPS M1330 with Intel Corporation Mobile GM965/GL960 Integrated Graphics Controller (rev 0c), and Fedora 11 is fully updated. Visiting the same site in Firefox does not cause a lockup. I am booting with nomodeset since it won't boot into X otherwise. I tried the other two accel options: EXA (still locks up) and XAA (X won't start). Any suggestions on how I can debug this? bugzilla

    Read the article

  • OS X Snow Leopard fails to boot after upgrade to 10.6.1

    - by pixeline
    I'm a fairly recent mac user. Been using windows for decades and happily switched. But i upgraded from 10.6 to 10.6.1 last night and the upgrade looks like it failed. I restarted the machine when it asked to then went to bed. In the morning the computer was still trying to shut itself off. So i forced the shutdown, restarted, but now i'm stuck with the loading spinner. What can i do? UPDATE: Verbose didn't show anything interesting. i also did the hardware test. Nothing comes up wrong. Disk utility did not find any error on the HD. But, it did show a fatal error when checking permissions.

    Read the article

  • Percona MySQL 5.5 fails to start

    - by keymone
    trying to setup new server here but keep getting this in error log: mysqld_safe Starting mysqld daemon with databases from /data/mysql/myisam [Warning] Can't create test file /data/mysql/myisam/hostname.lower-test [Warning] Can't create test file /data/mysql/myisam/hostname.lower-test [Note] Flashcache bypass: disabled [Note] Flashcache setup error is : setmntent failed /usr/sbin/mysqld: File '/var/mysql/bin/bin-log.index' not found (Errcode: 13) [ERROR] Aborting [Note] /usr/sbin/mysqld: Shutdown complete mysqld_safe mysqld from pid file /var/run/mysqld/mysqld.pid ended everything under /data/mysql (it's ibdata and myisam folders) is owned my mysql:mysql and has proper permissions same goes for folders with bin and relay logs under /var/mysql apparmor is purged from server any ideas? PS it seems like something else apart from apparmor is affecting permissions to access mysql files after i changed data directory to more default one - /var/lib/mysql and "Can't create test file" error is gone, but "'/var/mysql/bin/bin-log.index' not found (Errcode: 13)" is still there PPS so i installed apparmor back and added all folders to mysqld's profile and errors mentioned above are now gone(or mysql doesn't even get to that point now) what i have now is this: /usr/sbin/mysqld: error while loading shared libraries: libpthread.so.0: cannot open shared object file: No such file or directory banging my head against the wall.

    Read the article

  • Explanation of WCF application life cycle in IIS 6 hosting environment.

    - by David Christiansen
    Hi all and thanks for reading, I have a delay issue where my application takes a long time to start up when first called after an determinate period since the last call. The web application is a WCF service and we are talking about a delay of ~18seconds before the actual processing starts. Now, I believe I know how to reduce this delay so that is not my question (it's more a stackoverflow deal anyway) My question is, Can anyone explain to me why is it that despite me disabling worker process shutdown, and worker process recycling the application still 'winds down' after a indeterminate period of time of inactivity? To understand this I need to know more about the innerworkings of WCF services hosted in IIS. I fully expect there to be a straight forward answer to this. Thank you v. much for any help you may offer, DC

    Read the article

  • My Windows 8 computer does not come out of Standby

    - by Jikag
    My computer will not come out out of standby. It has had this issue ever since I bought it ~4 years ago. When I purchased it, It came with Vista, I have since upgraded it to 7 and now 8 Pro, each time hoping that it would fix the problem, each time finding that it did not. My computer is an HP Pavilion Model #: m9500y. The computer goes into standby, but does not come out of it properly. If Hybrid sleep in on, it does not respond at all. If Hybrid sleep is off, It comes out and I can see the desktop for a bit, but then the screen goes black again and I have to reboot. I have tried Running a sfc, and a chkdsk in case it's a corrupted file, but it hasn't helped. This isn't too serious an issue because I can just shutdown my computer and turn it on the old fashioned way, but it is annoying and I would appreciate some advice going forward as I'm currently stumped.

    Read the article

  • How to proceed setting up a secondary mysql linux slave?

    - by Algorist
    I have a mysql database master and slave in production. I want to setup additional mysql slave. There is around 15 Terabyte of data in the database and there are MYISAM and InnoDB tables in the database. I am thinking of below options: Shutdown master database and copy the mysql data folder to secondary slave. Can Innodb tables be copied like this? Run flush table with read lock, scp the file to new slave and unlock the table and this is possible for myisam tables, can I do the same for innodb tables too? Thanks for looking at the question.

    Read the article

< Previous Page | 35 36 37 38 39 40 41 42 43 44 45 46  | Next Page >