Search Results

Search found 109 results on 5 pages for 'comexception'.

Page 4/5 | < Previous Page | 1 2 3 4 5  | Next Page >

  • solution for RPC_E_ATTEMPTED_MULTITHREAD error caused by SPRequestContext caching SPSites?

    - by kerray
    Hi, I'm developing a solution for SharePoint 2007, and I'm using SPSecurity.RunWithElevatedPrivileges a lot, passing in UserToken of the SystemAccount. After reading http://hristopavlov.wordpress.com/2009/01/19/understanding-sharepoint-sprequest/ I finally began to understand why I get these System.Runtime.InteropServices.COMException (0x80010102): Attempted to make calls on more than one thread in single threaded mode. (Exception from HRESULT: 0x80010102 (RPC_E_ATTEMPTED_MULTITHREAD)) errors, but there seems to be no solution - "known issue in the product" The article is more then a year old. I wasn't able to find anything more recent and helpful, but I was hoping maybe someone else has? My code goes like this SPSecurity.RunWithElevatedPrivileges(delegate() { using (SPSite elevatedSite = new SPSite(web.Site.ID, web.Site.SystemAccount.UserToken)) { using (SPWeb elevatedWeb = elevatedSite.OpenWeb(web.ID)) { // some operations on lists and items obtained through elevatedWeb } } } The errors come up wherever such an elevated code is used, and more often when there are more users who use these functionalities, so I guess perhaps the elevated SPSite is getting cached and reused. Is there any way to solve this? If my understanding is correct, how to make Sharepoint forget about the cached SPSites, and use a fresh one instead? Thanks

    Read the article

  • Loading GeckoWebBrowser Exceptions

    - by Mostafa Mahdieh
    I get a strange exception when a window containing a GeckoWebBrowser is loaded. This is the exception message: An unhandled exception of type System.Runtime.InteropServices.COMException occurred in Skybound.Gecko.dll Additional information: Class not registered (Exception from HRESULT: 0x80040154 (REGDB_E_CLASSNOTREG)) This is the windows code: public partial class AddContents : Form { String path; public AddContents(String path) { this.path = path; InitializeComponent(); } private void exitToolStripMenuItem_Click(object sender, EventArgs e) { this.Close(); } private void AddContents_Load(object sender, EventArgs e) { geckoWebBrowser1.Navigate(path); } private int selId = 1; private bool updateMode = false; private void timer1_Tick(object sender, EventArgs e) { if (updateMode) update(); } private void geckoWebBrowser1_DocumentCompleted(object sender, EventArgs e) { timer1.Enabled = true; updateMode = true; } private void treeView1_AfterSelect(object sender, TreeViewEventArgs e) { geckoWebBrowser1.Navigate("javascript:scrollToBookmark(" + treeView1.SelectedNode.Tag + ")"); TreeNode selected = treeView1.SelectedNode; TreeNode prev = selected.PrevNode; TreeNode next = selected.PrevNode; if (prev == null) upButton.Enabled = false; if (next == null) downButton.Enabled = false; } private void update() { geckoWebBrowser1.Navigate("javascript:updateSelText()"); GeckoElement el = geckoWebBrowser1.Document.GetElementById("sel_result_991231"); if (el != null) { textBox1.Text = el.InnerHtml; addButton.Enabled = !textBox1.Text.Trim().Equals(String.Empty); } } private void textBox1_Enter(object sender, EventArgs e) { updateMode = false; } private void geckoWebBrowser1_DomMouseDown(object sender, GeckoDomMouseEventArgs e) { updateMode = true; update(); } private void geckoWebBrowser1_DomMouseUp(object sender, GeckoDomMouseEventArgs e) { updateMode = false; } private void addButton_Click(object sender, EventArgs e) { geckoWebBrowser1.Navigate("javascript:addIdToSel()"); TreeNode t = new TreeNode(textBox1.Text); t.Tag = selId; treeView1.Nodes.Add(t); selId++; } }

    Read the article

  • Exception using Querytables in Excel Automation

    - by sam
    Hi, I'm using Automation to populate a range in Excel using a querytable.. However, when I try to add a querytable to the qorksheet I get an exception. I checked the connection string and its working fine.. Can some one please help me with this?? public void writeproc1() { try { Worksheet ws = (Worksheet)wb.Worksheets.Add(Missing.Value, Missing.Value, Missing.Value, Missing.Value); Range rng = ws.get_Range("A1", "E14"); QueryTable qt = ws.QueryTables.Add("Data Source=(local)\\SQLEXPRESS;initial catalog=temp;Integrated Security=SSPI;", rng, "Select * From Table_1"); qt.RefreshStyle = XlCellInsertionMode.xlInsertEntireRows; qt.Refresh(false); } catch (Exception ex) { Console.WriteLine(ex.ToString()); Console.ReadKey(); } } Exception Thrown System.Runtime.InteropServices.COMException (0x800A03EC): Exception from HRESULT: 0x800A03EC at System.RuntimeType.ForwardCallToInvokeMember(String memberName, BindingFlags flags, Object target, Int32[] aWrapperTypes, MessageData& msgData) at Microsoft.Office.Interop.Excel.QueryTables.Add(Object Connection, Range Destination, Object Sql) at tmp.Program.writeproc1() in ...Projects\tmp\tmp\Program.cs:line 25

    Read the article

  • SPException: Catastrophic failure (Exception from HRESULT: 0x8000FFF (E_UNEXPECTED) in Sharepoint

    - by BeraCim
    Hi all: I've been trying to programmatically copy custom content type and its custom columns from one web to another for some time now, and every time I get some sort of error or exception. After yet more tries, I received another strange and cryptic exception from Sharepoint after clicking onto a newly copied custom column in a custom content type. I checked the logs, and this is what I got: Failed to find the content type schema for ct-1033-0x1000blahblahblahcontenttypeId while caching feature data. Unknown SPRequest error occurred. More informationL 0x8000ffff Unable to locate the xml-definition for CType with SPContentTypeId '0x0100MorecontenttypeId', exception: Microsoft.SharePoint.SPException: Catastrophic failure(Exception from HRESULT: 0x8000FFFF (E_UNEXPECTED)) ---> System.Runtime.InteropServices.COMException (0x8000FFFF): Catastrophic failure... ... at Microsoft.SharePoint.Library.SPRequestInternalClass.GetGlobalContentTypeXml(String bstrUrl, Int32 type, UInt 32 lcid, Object varIdBytes... It failed to find quite a few content type schema. I'm confused with what Sharepoint is trying to do here, and why a simple process of copying a custom content type from one web to another just wouldn't work in contrast to the information found on the web e.g. this. Appreciate any help to get over this problem. Thanks.

    Read the article

  • Crystal Reports - "A string is required here" formula error.

    - by George Mauer
    I have a command line utility that generates one simple crystal report. I recently updated the project from .NET 1.1 to .NET 3.5 using the Visual Studio 2008 migrator and am now getting an error that I had never received before. The problem is in the work_order formula which is as follows: stringVar nvl_ship_wrk_id := "0"; stringVar nvl_ship_wrk_seq := "0"; If Not IsNull({FeedBOLInput.ShipWrkId}) Then nvl_ship_wrk_id := {FeedBOLInput.ShipWrkId}; If Not IsNull({FeedBOLInput.ShipWrkSeq}) Then nvl_ship_wrk_seq := {FeedBOLInput.ShipWrkSeq}; nvl_ship_wrk_id & " - " & nvl_ship_wrk_seq; And the error is: - InnerException {"A string is required here. Error in File C:\\...\\temp_88c50533-02c6-4973-ae06-ed0ab1a603ac {0D5E96FB-038A-41C5-93A7-A9D199961377}.rpt: Error in formula <work_order>. 'stringVar nvl_ship_wrk_id := \"0\"; ' A string is required here."} System.Exception {System.Runtime.InteropServices.COMException} Does anyone have any idea what this can be? I'm out of clues. The dataset is coming in properly - and the error seems to point to a row which merely initializes a variable.

    Read the article

  • When programatically creating a new IIS web site, how can I add it to an existing application pool?

    - by Ian Robinson
    I have successfully automated the process of creating a new IIS website, however the code I've written doesn't care about application pools, it just gets added to DefaultAppPool. However I'd like to add this newly created site to an existing application pool. Here is the code I'm using to create the new website. var w3Svc = new DirectoryEntry(string.Format("IIS://{0}/w3svc", webserver)); var newsite = new object[] { serverComment, new object[] { serverBindings }, homeDirectory }; var websiteId = w3Svc.Invoke("CreateNewSite", newsite); site.Invoke("Start", null); site.CommitChanges(); <update Although this is not directly related to the question, here are some sample values being used above. This might help someone understand exactly what the code above is doing more easily. webServer: "localhost" serverComment: "testing.dev" serverBindings: ":80:testing.dev" homeDirectory: "c:\inetpub\wwwroot\testing\" </update If I know the name of the application pool that I'd like this web site to be in, how can I find it and add this site to it? <update 2 I've added the following based on Mark's answer below. var appPool = new DirectoryEntry(string.Format("IIS://{0}/w3svc/AppPools/{1}", webServer, appPoolName)); site.Properties["AppPoolId"].Value = appPool; I seem to have moved passed the "RPC" error message I was initially receiving. Now this is the error message I'm receiving: Error: System.Runtime.InteropServices.COMException (0x8000500C): Exception from HRESULT: 0x8000500C at System.DirectoryServices.Interop.UnsafeNativeMethods.IAds.PutEx(Int32 lnControlCode, String bstrName, Object vProp) at System.DirectoryServices.PropertyValueCollection.set_Value(Object value) at ProvisionIISWebsite.Query.CreateWebsite(String webServer, String serverComment, String serverBindings, String homeDirectory, String appPoolName) in C:\Users\irobinson\My Projects\ProvisionIISWebsite\Query.cs:line 104 at ProvisionIISWebsite.Query.Handle_GetData(EngineBase& caller, Boolean isSubQuery, String query, String filterField, String filterText, Debugger& debugWriter, Boolean isRendered, Int32 timeout, String customConnection) in C:\Users\irobinson\My Projects\ProvisionIISWebsite\Query.cs:line 36 </update 2

    Read the article

  • HRESULT of 0x806D0005 from Microsoft's Dia2Lib

    - by Aeolien
    I'm trying to read a PDB file into a C# application. When I call loadDataFromPdb or loadAndValidateDataFromPdb with a file that I know exists, I get an HRESULT of 0x806D0005. Unfortunately, I have no idea what that means. I have the list of possible results [here](http://msdn.microsoft.com/en-us/library/2008hf0e(v=VS.80).aspx) but I'm afraid I can't conclusively determine the problem. Does anybody know what I'm doing wrong? Or at least a method of checking what that corresponds to? Exception: System.Runtime.InteropServices.COMException (0x806D0005): Exception from HRESULT: 0x806D0005 at Dia2Lib.DiaSourceClass.loadDataFromPdb(String pdbPath) Code Sample: public static void LoadSymbolsForModule(uint baseAddress, uint size, uint timeStamp, DM_PDB_SIGNATURE signature) { IDiaDataSource m_source = new DiaSourceClass(); //m_source.loadAndValidateDataFromPdb(signature.path, ref signature.guid, 0, signature.age); m_source.loadDataFromPdb(signature.path); IDiaSession m_session; m_source.openSession(out m_session); m_session.loadAddress = baseAddress; modules.Add(new Module(baseAddress, size, m_session)); } Thanks in advance, guys. This problem has been killing me all day.

    Read the article

  • Crystal report error message

    - by Selom
    Hi, ive been dealing with a kind of no error message my application is throwing after the setup has been installed on my machine. The application run fine and generate a report exactly the way i want it. The problem is that after compiling it as set up, it throw this message: System.Runtime.InteropServices.COMException (0x80000000); No error. at CrystalDesisionsReportAppServer.Controllers.DatabaseControllerClass.ReplaceConnection(Object oldConnection, Object newConnection, Object parameterFields, Object crDBOptionUseDefault) at CrystalDecisions.CrystalReports.Engine.ReportDocument.SetDataSourceInternal(Object val, Type type) at CrystalDecisions.CrystalReports.Engine.ReportDocument.SetDataSource(DataSet dataSet) at Presby_Soft.reportFrm.reportFrm_Load(Object sender, EventArgs e) this is the code im using: Private Sub reportFrm_Load(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles MyBase.Load If conn.State = ConnectionState.Closed Then conn.Open() End If Try Dim rpt As New CrystalReport1() Dim da As New SQLiteDataAdapter Dim ds As New presbydbDataSet 'Dim cmd As New SQLiteCommand("SELECT personal_details.fn, training.training_level FROM personal_details INNER JOIN training ON personal_details.Staff_ID ='" + detailsFrm.Label13.Text + "'", conn) Dim cmd As New SQLiteCommand("SELECT * FROM personal_details WHERE personal_details.staff_ID='" + detailsFrm.Label13.Text + "'", conn) cmd.ExecuteNonQuery() da.SelectCommand = cmd da.Fill(ds, "personal_details") rpt.Subreports.Item("persoRpt").SetDataSource(ds) CrystalReportViewer1.ReportSource = rpt Catch ex As Exception MsgBox(ex.ToString) End Try conn.Close() End Sub Please help, I really don't know how to go about this problem. Thanks for answering

    Read the article

  • How can I set PivotField.Calculation in Excel/VSTO?

    - by Kang Su
    I'm trying to set the Calculation property on an OLAP PivotField with VSTO 3.0. For example: pivotField.Calculation = XlPivotFieldCalculation.PercentOf; If I do the above, the value I assign does not stay (Excel appears to revert the change). I suspect the reason is that the BaseField property of the PivotField also needs to be populated (as PercentOf needs a BaseField). But it appears to me that you can't set the BaseField property until you've set the Calculation property (otherwise you get a COMException). I've tried to set ManualUpdate on the PivotTable to true, but with VSTO this rarely works, as this gets reverted immediately back to false. Note, that this seems to work fine in VBA as you can assign multiple values in a single statement, like this: With ActiveSheet.PivotTables("PivotTable1").PivotFields("[Measures].[Reseller Sales Amount]") .Calculation = xlPercentOf .BaseField = "[Geography].[Geography].[Country]" .BaseItem = "[Geography].[Geography].[Country].&[France]" .NumberFormat = "0.00%" End With But with C#/VSTO there's no construct like this (that I know of) and I'm stuck not able to do something like the above. Further note, Calculation values that don't require a BaseField, e.g., XlPivotFieldCalculation.xlPercentOfTotal, get set just fine. Any help on this would be greatly appreciated!

    Read the article

  • Problems requesting the LDAP: The server is unwilling to process the request.

    - by Flo
    We have written an authentication provider for a SharePoint web application which can requests multiple LDAP directories. One of the LDAP server have to be requested via SSL. So we imported the CA certificate which was used to sign the LDAP server's certificate into the certificate store of the SharePoint server. The following code snippet shows how we authenticate an user. The passed credentials (account, password) belong to the user we want to authenticate. var entry = new DirectoryEntry("LDAP://<ldap-server-address>", "cn=account,ou=sub,o=xyz,c=de", "password", AuthenticationTypes.SecureSocketsLayer); var searcher = new DirectorySearcher(entry); var found = searcher.FindOne(); When the code is processed, the call to searcher.FindOne() throws following exception. System.Runtime.InteropServices.COMException (0x80072035): The server is unwilling to process the request What circumstance can lead to this error? UPDATE: I found some information about the error message. There the problem seems to be the certificate store, as the user has only stored the certificate in the in the user's store and not in the computer's store. Unfortunately we've already stored it there. So could this be still a certificate issue? UPDATE/SOLUTION: Actually the problem is solved. It seems as if the root CA certificate was imported correctly but the error messages the LDAP server responded was caused by an expired user account our customer gave us for testing.

    Read the article

  • Do you have ideas for a workaround for this Known bug in Visual Studio 2010's addIn model ?

    - by Jesper
    When developing AddIns for Visual Studio 2010 the following line fails: CommandBarEvents handler = (EnvDTE.CommandBarEvents)m_VSStudio.DTE.Events.get_CommandBarEvents(popup); Update: Forgot to tell that m_VSStudio is of the type DTE2 Where popup is of the type CommandBarPopup (for the type CommandBarControl it works though) The line fails with this Exception: System.Runtime.InteropServices.COMException (0x80020003): Member not found. (Exception from HRESULT: 0x80020003 (DISP_E_MEMBERNOTFOUND)) The exact same line worked in Visual Studio 2008. The purpose of the line is to get a handler which handles clickevents, when one clicks the Popup. After som searching I found this link: http://connect.microsoft.com/VisualStudio/feedback/details/524335/events-get-commandbarevents-exception-on-submenus-reproducible-bug-addin Which basicly states that it is a known bug, which will not be fixed, because there is a workaround. But unfortunately it does not state the workaround :( I would be extremely pleased if anybody has a great idea for a workaround ? The reason why I want to listen to the click events is because I want to show or hide the submenuitems (CommandBarControl) given some condition, when one clicks a menu (CommandBarPopup). So a workaround that uses something else than the click event would also be appreciated.

    Read the article

  • PartCover 2.5.3 win 7 x64

    - by user329814
    Could you tell me how you got PartCover running with VS2008 and win 7 x64? Based on this post http://stackoverflow.com/questions/256287/how-do-i-run-partcover-in-x64-windows, I ran c:\Program Files (x86)\Gubka Bob\PartCover .NET 2.3>CorFlags.exe PartCover.exe / 32BIT+ /Force with result Microsoft (R) .NET Framework CorFlags Conversion Tool. Version 3.5.21022.8 Copyright (c) Microsoft Corporation. All rights reserved. corflags : warning CF011 : The specified file is strong name signed. Using /Force will invalidate the signature of this image and will require the assembly to be resigned. and c:\Program Files (x86)\NUnit 2.5.2\bin\net-2.0>CorFlags.exe nunit.exe /32BIT+ /Force with result Microsoft (R) .NET Framework CorFlags Conversion Tool. Version 3.5.21022.8 Copyright (c) Microsoft Corporation. All rights reserved. Also, based on my discussion http://stackoverflow.com/questions/2546340/using-partcover-2-3-with-net-4-0-runtime/2964333#2964333, I also tried to use the x86 version of NUnit What I'm trying to run coverage for is the c# money sample for NUnit 2.5.2 I get the same System.Threading.ThreadInterruptedException --- System.Runtime.InteropServices.COMException (0x80040153): Retrieving the COM class factory for component with CLSID {FB20430E-CDC9-45D7-8453-272268002E08} failed due to the following error: 80040153 Thank you Edit: same thing with PartCover 2.2 My settings: exe file: C:\Program Files (x86)\NUnit 2.5.2\bin\net-2.0\nunit-console-x86.exe working dir: c:\Program Files (x86)\NUnit 2.5.2\samples\csharp\money\ work arg: /config=c:\Program Files (x86)\NUnit 2.5.2\samples\csharp\money\cs-money.csproj rules: +[]

    Read the article

  • Trouble running setup package after Publishing in Visual Studio 2008

    - by Andrew Cooper
    I've got a small winform application that I've written that is running fine in the IDE. It builds with no errors or warnings. It's not using any third party controls. I'm coding in C# in Visual Studio 2008. When I Build -- Publish the application, everything seems to work fine. However, when I go and attempt to install the application via the setup.exe file I get an error message that says, "Application cannot be started." The error details are below: ERROR DETAILS Following errors were detected during this operation. * [3/18/2010 10:50:56 AM] System.Runtime.InteropServices.COMException - The referenced assembly is not installed on your system. (Exception from HRESULT: 0x800736B3) - Source: System.Deployment - Stack trace: at System.Deployment.Internal.Isolation.IStore.GetAssemblyInformation(UInt32 Flags, IDefinitionIdentity DefinitionIdentity, Guid& riid) at System.Deployment.Internal.Isolation.Store.GetAssemblyManifest(UInt32 Flags, IDefinitionIdentity DefinitionIdentity) at System.Deployment.Application.ComponentStore.GetAssemblyManifest(DefinitionIdentity asmId) at System.Deployment.Application.ComponentStore.GetSubscriptionStateInternal(DefinitionIdentity subId) at System.Deployment.Application.SubscriptionStore.GetSubscriptionStateInternal(SubscriptionState subState) at System.Deployment.Application.ComponentStore.CollectCrossGroupApplications(Uri codebaseUri, DefinitionIdentity deploymentIdentity, Boolean& identityGroupFound, Boolean& locationGroupFound, String& identityGroupProductName) at System.Deployment.Application.SubscriptionStore.CommitApplication(SubscriptionState& subState, CommitApplicationParams commitParams) at System.Deployment.Application.ApplicationActivator.InstallApplication(SubscriptionState& subState, ActivationDescription actDesc) at System.Deployment.Application.ApplicationActivator.PerformDeploymentActivation(Uri activationUri, Boolean isShortcut, String textualSubId, String deploymentProviderUrlFromExtension, BrowserSettings browserSettings, String& errorPageUrl) at System.Deployment.Application.ApplicationActivator.ActivateDeploymentWorker(Object state) I'm not sure what else to do. The only slightly odd thing I used in this application is the SQL Compact Server. Any help would be appreciated. Thanks, Andrew

    Read the article

  • Handling Digital ID/Signature in Outlook Add-in

    - by CoSteve
    I have a C# Outlook Add-In application (VS2005 and 2003 Outlook) that reads incoming emails and strips out the attachments and the email text body for future processing. Occasionally I'll get an email that contains a digital signature. The application will fail when I try to access the mailitem.body property, throwing the following exception: System.Runtime.InteropServices.COMException (0xAB404001): The operation failed. at Microsoft.Office.Interop.Outlook._MailItem.get_Body() at MyLib.MyApp.OutlookAddin.MailProcessor.ProcessMailItem(MailItem mailItem) I'm pretty sure it is the digital signature causing the problem because if I forward the email back to myself, it will strip off the original sender's digital signature and the add-in application will process the email without any problems. I'm not sure what to do. I need to process the email, so I can't just ignore it. Somehow getting the body of the original email without throwing an exception would be ideal. Or I guess if I can identify that there is a digital signature associated with the email, I could forward the email to myself, but that seems a little messy. Does anyone have any suggestions/fixes? Thanks for any help.

    Read the article

  • Worksheet.Unprotect - Office Interop - Difference between 2003 and 2007

    - by sdmcnitt
    I have a .NET winforms app that automates Excel and checks for a worksheet password. The requirements are to be able to detect 1) that the protection is turned off 2) that the password is removed (protected but there is no password) 3) that the password matches the correct password from a database To meet the second requirement the program calls the Worksheet.Unprotect command with a null string, capturing the error. If error as expected, the 3rd check is made. If no error, then the Unprotect worked without a password == password was removed. The code sample below has these checks. The application can do this fine with Office 2003. I have since had my dev machine updated to Office 2007 and it no longer works as it did. When I call the Worksheet.Unprotect, Excel prompts for the password! I need to know how this should be accomplished in the new version of Excel or if there is a way to reference the old PIA. No matter what if I set a reference to Excel 11 it is replaced with the PIA for 12 in the GAC. 'return true if unprotect of worksheet does not generate an error 'all other errors will bubble up 'return false if specific error is "Password is invalid..." Try 'detect unprotected or no password If oWorksheet.ProtectContents Then 'try with no passsword and expect an error 'if no error then raise exception Dim blnRaiseException As Boolean = True Try 'oWorksheet.Unprotect(vbNullString) oWorksheet.Unprotect() Catch ex As Exception blnRaiseException = False End Try If blnRaiseException Then Throw New ExcelSheetNoPasswordException End If oWorksheet.Unprotect(strPwd) 'no error so if we get here -- success fnCheckWorksheetPwd = True 'leave as it was -- this may still cause workbook to think it is changed oWorksheet.Protect(strPwd) Else Throw New ExcelSheetNotProtectedException End If Catch COMex As System.Runtime.InteropServices.COMException 'handle error code -2146827284 If COMex.ErrorCode = -2146827284 Then 'this is the error we're looking for Else Throw End If Catch ex As Exception Throw End Try

    Read the article

  • Help with debugging COM errors? (.mdi to .pdf file conversions using Microsoft Office Document Imagi

    - by RyanW
    I thought I had a working solution for converting .mdi files to PDF using the Microsoft Office Document Imaging object model. The solution is in a Windows Service, but now I'm running into some errors that I'm having trouble tracking down info on. The exception I get is: The server threw an exception. (Exception from HRESULT: 0x80010105 (RPC_E_SERVERFAULT)) System.Runtime.InteropServices.COMException (0x80010105): The server threw an exception. (Exception from HRESULT: 0x80010105 (RPC_E_SERVERFAULT)) at MODI.DocumentClass.Create(String FileOpen) at DocumentStore.Mdi2PDF(String path, String newPath) Then, in the Event Viewer there is the following Application error: Faulting application MyWindowsServiceName.exe, version 1.0.0.0, time stamp 0x4b97f185, faulting module mso.dll, version 12.0.6425.1000, time stamp 0x49d65443, exception code 0xc0000005, fault offset 0x0000bd8e, process id 0xa5c, application start time 0x01cac08cf032914b. Here's the method that is doing the conversion: private int? Mdi2PDF(String path, String newPath) { int? pageCount = null; string tmpTif = Path.GetTempFileName(); MODI.Document mdiDoc = new MODI.Document(); mdiDoc.Create(path); mdiDoc.SaveAs(tmpTif, MODI.MiFILE_FORMAT.miFILE_FORMAT_TIFF_LOSSLESS, MODI.MiCOMP_LEVEL.miCOMP_LEVEL_HIGH); mdiDoc.Close(false); pageCount = Tiff2PDF(tmpTif, newPath); if (File.Exists(tmpTif)) File.Delete(tmpTif); return pageCount; } I removed all threading from the service invoking this, so that only the primary thread was initializing the MODI object, but still got the error, so it doesn't appear to be threading related. I also built a a console apps converting hundreds of documents and DID NOT get the exception. So, it seems to be caused by creating too many instances of the MODI object, but only instantiated within a Service? Doesn't quite make sense. Anybody have any clues about these errors and how to debug them further?

    Read the article

  • error to start Windows Media Encoder

    - by George2
    Hello everyone, I am using the following code snippet to run on Windows Server 2003 x64 edition. I met with the following error when invoking encoder.start method. I am using Windows Media Encoder 9. System.Runtime.InteropServices.COMException 0xC00D1B67 My code snippet is below, does anyone have any ideas what is wrong? IWMEncSourceGroup SrcGrp; IWMEncSourceGroupCollection SrcGrpColl; SrcGrpColl = encoder.SourceGroupCollection; SrcGrp = (IWMEncSourceGroup)SrcGrpColl.Add("SG_1"); IWMEncVideoSource2 SrcVid; IWMEncSource SrcAud; SrcVid = (IWMEncVideoSource2)SrcGrp.AddSource(WMENC_SOURCE_TYPE.WMENC_VIDEO); SrcAud = SrcGrp.AddSource(WMENC_SOURCE_TYPE.WMENC_AUDIO); SrcVid.SetInput("ScreenCap://ScreenCapture1", "", ""); SrcAud.SetInput("Device://Default_Audio_Device", "", ""); // Specify a file object in which to save encoded content. IWMEncFile File = encoder.File; string CurrentFileName = Guid.NewGuid().ToString(); File.LocalFileName = CurrentFileName; CurrentFileName = File.LocalFileName; // Choose a profile from the collection. IWMEncProfileCollection ProColl = encoder.ProfileCollection; IWMEncProfile Pro; for (int i = 0; i < ProColl.Count; i++) { Pro = ProColl.Item(i); if (Pro.Name == "Screen Video/Audio High (CBR)") { SrcGrp.set_Profile(Pro); break; } } encoder.Start(); thanks in advance, George

    Read the article

  • Programmatically modifying a file on Windows Server 2008 (Web Ed.)

    - by Tom
    I have written a .NET 2008 application, incorporating Microsoft.Office.Interop.Excel, that modifies an existing Excel 2007 spreadsheet. It works perfectly on my WinXP development computer. When I upload the app to a Microsoft Web Server 2008, it opens the file and reads from the file, but when the app tries to save the file, it throws this exception: "System.Runtime.InteropServices.COMException (0x800A03EC): 'july2009.xlsx' is read-only. To save a copy, click OK, then give the workbook a new name in the Save As dialog box." The file is NOT read-only, nor is it opened by any other user or app. The app and the Excel file both reside on the D: (data-only) drive. My first instinct was to look at file permissions. When nothing else worked, I literally created a temporary Group, added EVERY user and security entity to it and granted the group full control of the entire D: drive. No luck. Then I tried manually elevating the permission by running my app as administrator. No luck. Finally, I copied the file to my XP development computer and ran the app there. Of course it worked perfectly. Can anyone please tell me how to give my program permission to edit a file on Server 2008? Thanks!

    Read the article

  • Exposing a .Net Service

    - by Dave
    I have written a Windows Service in .Net and I want to expose the classes to be called by other .Net code. Specifically, I have an API that I want to expose via a DLL that will be placed in the GAC, and I want the DLL in the GAC to use the classes of the .Net Windows Service. I need this architecture as the code in the Windows Service needs to be run as a different user/account as the caller of the API (the account would be created at install time). My plan was to expose the Windows Service classes via COM (regasm.exe to register and tlbexp.exe to create the type library), and then call the classes in the GAC DLL via COM (imported via tlbimp.exe). However I get the following error from tlbimp: TlbImp : error TI0000 : System.Runtime.InteropServices.COMException - Type library '' was exported from a CLR assembly and cannot be re- imported as a CLR assembly. This implies to me that my method is not going to easily work. I can only think that I might need a C++ DLL as a bridge for my GAC DLL to invoke the COM calls, but this seems like a nasty solution. I am basically looking for suggestions. Does anyone know how to expose classes of a Windows Service written in .Net to other .Net code?

    Read the article

  • Why does my call to Activator.CreateInstance intermittently fail?

    - by Daniel Stutzbach
    I'm using the following code to access the Windows Explorer Shell's band site service: Guid GUID_TrayBandSiteService = new Guid(0xF60AD0A0, 0xE5E1, 0x45cb, 0xB5, 0x1A, 0xE1, 0x5B, 0x9F, 0x8B, 0x29, 0x34); Type shellTrayBandSiteService = Type.GetTypeFromCLSID(GUID_TrayBandSiteService, true); site = Activator.CreateInstance(shellTrayBandSiteService) as IBandSite; Mostly, it works great. A very small percentage of the time (less than 1%), the call to Activator.CreateInstance throws the following exception: System.Runtime.InteropServices.COMException (0x80040154): Retrieving the COM class factory for component with CLSID {F60AD0A0-E5E1-45CB-B51A-E15B9F8B2934} failed due to the following error: 80040154. at System.RuntimeTypeHandle.CreateInstance(RuntimeType type, Boolean publicOnly, Boolean noCheck, Boolean& canBeCached, RuntimeMethodHandle& ctor, Boolean& bNeedSecurityCheck) at System.RuntimeType.CreateInstanceSlow(Boolean publicOnly, Boolean fillCache) at System.RuntimeType.CreateInstanceImpl(Boolean publicOnly, Boolean skipVisibilityChecks, Boolean fillCache) at System.Activator.CreateInstance(Type type, Boolean nonPublic) I've looked up the error code, and it appears to indicate that the service isn't registered. That's nonsense in my case, since I'm trying to access a service provided by the operating system (explorer.exe, to be specific). I'm stumped. What might cause Activator.CreateInstance fail, but only rarely?

    Read the article

  • Enumerating computers in NT4 domain using WNetEnumResourceW (C++) or DirectoryEntry (C#)

    - by Kevin Davis
    I'm trying to enumerate computers in NT4 domains (not Active Directory) and support Unicode NetBIOS names. According to MSDN, WNetEnumResourceW is the Unicode counterpart of WNetEnumResource which to me would imply that using this would do the trick. However, I have not been able to get Unicode NetBIOS names properly using WNetEnumResourceW. I've also tried the C# rough equivalent DirectoryEntry using the WinNT: provider with no luck on Unicode names either. If I use DirectoryEntry on Active Directory (using the LDAP: provider) I do get Unicode names back. I noticed that during some debugging my code using DirectoryEntry and the WinNT: provider, the exceptions I saw were of type System.Runtime.InteropServices.COMException which tends to make me believe that this is just calling WNetEnumResourceW via COM. This web page implies that for some Net APIs the MS documentation is incomplete and possibly inaccurate which further confuses things. Additionally I've found that using the C# method which certainly results in cleaner, more understandable code also yields incomplete results in enumerating computers in domains\workgroups. Does anyone have any insight on this? Is it possible that computer acting as the WINS server is mangling the name? How would I determine this? Thanks

    Read the article

  • What VC++ compiler/linker does when building a C++ project with Managed Extension

    - by ???
    The initial problem is that I tried to rebuild a C++ project with debug symbols and copied it to test machine, The output of the project is external COM server(.exe file). When calling the COM interface function, there's a RPC call failre: COMException(0x800706BE): The remote procedure call failed. According to the COM HRESULT design, if the FACILITY code is 7, it's actually a WIN32 error, and the win32 error code is 0x6BE, which is the above mentioned "remote procedure call failed". All I do is replace the COM server .exe file, the origin file works well. When I checked into the project, I found it's a C++ project with Managed Extension. When I checking the DLL with reflector, it shows there's 2 additional .NET assembly reference. Then I checked the project setting and found nothing about the extra 2 assembly reference. I turned on the show includes option of compiler and verbose library of linker, and try to analyze whether the assembly is indirectly referenced via .h file. I've collect all the .h file and grep all the files with '#using' '#import' and the assembly file itself. There really is a '#using ' in one of the .h file but not-relevant to the referenced assembly. And about the linked .lib library files, only one of the .lib file is a side-product of another managed-extension-enabled C++ project, all others are produced by a pure, traditional C++ project. For the managed-extension-enabled C++ project, I checked the output DLL assembly, it did NOT reference to the 2 assembly. I even try to capture the access of the additional assembly file via sysinternal's filemon and procmon, but the rebuild process does NOT access these file. I'm very confused about the compile and linking process model of a VC++/CLI project, where the additional assembly reference slipped into the final assembly? Thanks in advance for any of your help.

    Read the article

  • How do I create and send appointments to Microsoft Outlook calender?

    - by Shyju
    I am trying to create an appointment in the Microsoft Outlook (2003) calender of another person using the below code.While running this program, The Appointment is getting saved in my calender.But not being sent to the recipient. try { Microsoft.Office.Interop.Outlook.Application app = null; Microsoft.Office.Interop.Outlook.AppointmentItem appt = null; app = new Microsoft.Office.Interop.Outlook.Application(); appt = (Microsoft.Office.Interop.Outlook.AppointmentItem)app .CreateItem(Microsoft.Office.Interop.Outlook.OlItemType.olAppointmentItem); appt.Subject = "Meeting "; appt.Body = "Test Appointment body"; appt.Location = "TBD"; appt.Start = Convert.ToDateTime("12/23/2009 05:00:00 PM"); appt.Recipients.Add("[email protected]"); appt.End = Convert.ToDateTime("12/23/2009 6:00:00 PM"); appt.ReminderSet = true; appt.ReminderMinutesBeforeStart = 15; appt.Importance = Microsoft.Office.Interop.Outlook.OlImportance.olImportanceHigh; appt.BusyStatus = Microsoft.Office.Interop.Outlook.OlBusyStatus.olBusy; appt.Save(); appt.Send(); } catch (COMException ex) { Response.Write(ex.ToString()); } Am i missing anything? Can any one help me out to solve this issue?

    Read the article

  • Unable to diligently close the excel process running in memory

    - by NewAutoUser
    I have developed a VB.Net code for retrieving data from excel file .I load this data in one form and update it back in excel after making necessary modifications in data. This complete flow works fine but most of the times I have observed that even if I close the form; the already loaded excel process does not get closed properly. I tried all possible ways to close it but could not be able to resolve the issue. Find below code which I am using for connecting to excel and let me know if any other approach I may need to follow to resolve this issue. Note: I do not want to kill the excel process as it will kill other instances of the excel Dim connectionString As String connectionString = "Provider=Microsoft.Jet.OLEDB.4.0; Data Source=" & ExcelFilePath & "; Extended Properties=excel 8.0; Persist Security Info=False" excelSheetConnection = New ADODB.Connection If excelSheetConnection.State = 1 Then excelSheetConnection.Close() excelSheetConnection.Open(connectionString) objRsExcelSheet = New ADODB.Recordset If objRsExcelSheet.State = 1 Then objRsExcelSheet.Close() Try If TestID = "" Then objRsExcelSheet.Open("Select * from [" & ActiveSheet & "$]", excelSheetConnection, 1, 1) Else objRsExcelSheet.Open("Select Test_ID,Test_Description,Expected_Result,Type,UI_Element,Action,Data,Risk from [" & ActiveSheet & "$] WHERE TEST_Id LIKE '" & TestID & ".%'", excelSheetConnection, 1, 1) End If getExcelData = objRsExcelSheet Catch errObj As System.Runtime.InteropServices.COMException MsgBox(errObj.Message, , errObj.Source) Return Nothing End Try excelSheetConnection = Nothing objRsExcelSheet = Nothing

    Read the article

  • .Net Crystal Report printing application running on termianal service connection errors when session

    - by MrEdmundo
    I have created a .Net application to run on an App Server that gets requests for a report and prints out the requested report. The C# application uses Crystal Reports to load the report and subsequently print it out. The application is run on Server which is connected to via a Remote Desktop connection under a particular user account (required for old apps). When I disconnect from the Remote Session the application starts raising exceptions such as: Message: CrystalDecisions.Shared.CrystalReportsException: Load report failed This type of error is never raised when the Remote Session is active. The server running the app is running Windows Server 2003, my box which creates the connection is Windows XP. I appreciate this is fairly weird, however I cannot see any problem with the application deployment I have created. Does anyone know what could be cause this issue? EDIT: I bit the bullet and created the application as a windows service, obviously this doesn't take long I just wasn't convinced it would solve the problem. Anyway it doesn't!!! I have also tried removing the multi-thread code that was calling the print function asynchronously. I did this in order to simply the app and narrow down the reason it could fail. Anyway, this didn't improve the situation either! EDIT: The two errors I get are: System.Runtime.InteropServices.COMException (0x80000201): Invalid printer specified. at CrystalDecisions.ReportAppServer.Controllers.PrintOutputControllerClass.ModifyPrinterName(String newVal) at CrystalDecisions.CrystalReports.Engine.PrintOptions.set_PrinterName(String value) at Dsa.PrintServer.Service.Service.PrintCrystalReport(Report report) The printer isn't invalid, this is confirmed when 60 seconds later the time ticks and the report is printed successfully. And The request could not be submitted for background processing. at CrystalDecisions.ReportAppServer.Controllers.ReportSourceClass.GetLastPageNumber(RequestContext pRequestContext) at CrystalDecisions.ReportSource.EromReportSourceBase.GetLastPageNumber(ReportPageRequestContext reqContext) --- End of inner exception stack trace --- at CrystalDecisions.ReportAppServer.ConvertDotNetToErom.ThrowDotNetException(Exception e) at CrystalDecisions.ReportSource.EromReportSourceBase.GetLastPageNumber(ReportPageRequestContext reqContext) at CrystalDecisions.CrystalReports.Engine.FormatEngine.PrintToPrinter(Int32 nCopies, Boolean collated, Int32 startPageN, Int32 endPageN) at CrystalDecisions.CrystalReports.Engine.ReportDocument.PrintToPrinter(Int32 nCopies, Boolean collated, Int32 startPageN, Int32 endPageN) at Dsa.PrintServer.Service.Service.PrintCrystalReport(Report report) EDIT: I ran filemon to check if there were any access issue. At the point when the error occurs file mon reports Request: OPEN | Path: C:\windows\assembly\gac_msil\system\2.0.0.0__b77a5c561934e089\ws2_32.dll | Result: NOT FOUND | Other: Attributes Error

    Read the article

< Previous Page | 1 2 3 4 5  | Next Page >