  • Choice of an OS for a home ZFS NAS

    - by OlafM
    I am preparing a home NAS with an old Athlon 64 X2 3800+, 4 GB ECC RAM, Asus M2V MX motherboard, and a single 3 TB WDC Green (another one as mirror may be installed in the future). It's the cheapest solution I found that includes ECC memory and the higher energy consumption is offset by the lower (zero) cost of acquisition. The system will be used for: music storage and stream to other desktop computers; storage of the scanned dia slides (3-4k slides, 180 MB TIFF each one plus reduced quality JPEG version); stream of these photos to a local iPad 2 (maybe Plex App? not yet sure); (one additional) remote backup via rsync/ssh or ZFS send/receive. It will be controlled via remote ssh, maybe VNC, no monitor attached. Absolute requirement is a reliable ZFS solution, plus the ability to easily install packets/software/virtual machines and to update remotely (I will be the admin and I don't live near the NAS). I have mainly three options: NAS4free/FreeNAS OpenIndiana Solaris Express 11 (yeah yeah I know the license requirements, I will write a perl script on it to count it as development machine). Problems: NAS4free/FreeNAS (I tested only NAS4free) required embedded installation for remote upgrading, but full install for easy addition of software packets. Since I need at least AirVideo Server (linux/win) and Plex App (win/linux) to stream the photos and some videos to iPad (they both require virtualbox), but I cannot be there to install updates, NAS4free/FreeNAS are excluded. http://www.nas4free.org/general_information.html explains the issue: embedded can be remotely updated, full cannot. Solaris has also another advantage: Crashplan client supports Solaris and I'm already using it for other backups. I would like to leave the option open, even if I will be doing backups probably through zfs send/receive. NexentaStor was left out because zfs send/receive are not included in the free version. The question is now Solaris 11 Express over OpenIndiana. To ease the management, I will be using http://www.napp-it.org Which one would you suggest and why? I found lots of informations and it's difficult for me to decide. I think (from the napp-it manual) that Solaris has some additional options for SMB shares, but are they really needed at home? I think I won't even use ACLs, since normal unix-style permissions are enough. OpenIndiana has maybe more frequent updates (Solaris offers only security updates between releases), but again, do I need them? I don't think so. Moreover, this is a NAS that has to work and nothing else, I cannot risk having problems that require me to access the server. Isn't OpenIndiana a bit more... cutting edge (in the Solaris world)? I'm just asking, no need to focus on this for the answer :-) I would limit myself to these two options (SE11.1/OI) also because I will be making a NAS for me in the future (where high performances with Mac shares are also required) and Solaris has kernel support for AFP. I will use this server to gather experience as well. After this long question, thanks in advance! If you need additional info, let me know and I will update this post. UPDATES Given the first answers, I will strongly suggest the person paying the hardware to insert a second HD. Better 2x2TB than 1x3TB (3 TB is oversized anyway). I was trying to keep the initial costs down to spread them over a longer period, but better having something good from the beginning.

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • Recommendation for PHP-FPM pm.max_children, PHP-FPM pm.start_servers and others

    - by jaypabs
    I have the following server: Intel® Xeon® E3-1270 v2 Single Processor - Quad Core Dedicated Server CPU Speed: 4 x 3.5 Ghz w/ 8MB Smart Cache Motherboard: SuperMicro X9SCM-F Total Cores: 4 Cores + 8 Threads RAM: 32 GB DDR3 1333 ECC Hard Drive: 120GB Smart Cache: 8MB I am using ubuntu 12.04 - nginx, php, mysql with ISPConfig 3. Under ISPConfig 3 website settings: I have this default value: PHP-FPM pm.max_children = 10 PHP-FPM pm.start_servers = 2 PHP-FPM pm.min_spare_servers = 1 PHP-FPM pm.max_spare_servers = 5 PHP-FPM pm.max_requests = 0 My question is what is the recommended settings for the above variable? Because I found some using a different settings.

    Read the article

  • Hardware error messages from syslogd

    - by Farhat
    I have a 64-core AMD server running CEntOS on which I was running a long job. In the midst of the output, I see these lines. It appears to be a memory error. How severe is this and what exactly does it indicate? Message from syslogd@heracles at Nov 7 21:00:02 ... kernel:[Hardware Error]: MC4_STATUS[Over|CE|MiscV|-|AddrV|-|-|CECC]: 0xdc10410040080a13 Message from syslogd@heracles at Nov 7 21:00:02 ... kernel:[Hardware Error]: Northbridge Error (node 4): DRAM ECC error detected on the NB. Message from syslogd@heracles at Nov 7 21:00:02 ... kernel:[Hardware Error]: cache level: L3/GEN, mem/io: MEM, mem-tx: RD, part-proc: RES (no timeout)

    Read the article

  • Dell R610 memory configuration for all 12 slots

    - by Neal
    I purchased 12 sticks of RAM on eBay to go into a Dell R610 server. The RAM is ECC REG PC3-12800 DDR3-1600 yet when I occupy all 12 slots with this ram I get the following error on boot: MEMORY Initialization Warning: Memory Size May be Reduced MEMBIST failure – The following DIMM has been disabled by Bios: DIMM B2 MEMBIST failure – The following DIMM has been disabled by Bios: DIMM B5 I am using all of the latest versions, BIOS, etc. I am using 2 x x5660 processors. What is causing this issue and is it correctable? If this RAM is incorrect what is correct to maximize the RAM on this server? Thank you.

    Read the article

  • Mysql performance problem & Failed DIMM

    - by murdoch
    Hi I have a dedicated mysql database server which has been having some performance problems recently, under normal load the server will be running fine, then suddenly out of the blue the performance will fall off a cliff. The server isn't using the swap file and there is 12GB of RAM in the server, more than enough for its needs. After contacting my hosting comapnies support they have discovered that there is a failed 2GB DIMM in the server and have scheduled to replace it tomorow morning. My question is could a failed DIMM result in the performance problems I am seeing or is this just coincidence? My worry is that they will replace the ram tomorrow but the problems will persist and I will still be lost of explanations so I am just trying to think ahead. The reason I ask is that there is plenty of RAM in the server, more than required and simply missing 2GB should be a problem, so if this failed DIMM is causing these performance problems then the OS must be trying to access the failed DIMM and slowing down as a result. Does that sound like a credible explanation? This is what DELLs omreport program says about the RAM, notice one dimm is "Critical" Memory Information Health : Critical Memory Operating Mode Fail Over State : Inactive Memory Operating Mode Configuration : Optimizer Attributes of Memory Array(s) Attributes : Location Memory Array 1 : System Board or Motherboard Attributes : Use Memory Array 1 : System Memory Attributes : Installed Capacity Memory Array 1 : 12288 MB Attributes : Maximum Capacity Memory Array 1 : 196608 MB Attributes : Slots Available Memory Array 1 : 18 Attributes : Slots Used Memory Array 1 : 6 Attributes : ECC Type Memory Array 1 : Multibit ECC Total of Memory Array(s) Attributes : Total Installed Capacity Value : 12288 MB Attributes : Total Installed Capacity Available to the OS Value : 12004 MB Attributes : Total Maximum Capacity Value : 196608 MB Details of Memory Array 1 Index : 0 Status : Ok Connector Name : DIMM_A1 Type : DDR3-Registered Size : 2048 MB Index : 1 Status : Ok Connector Name : DIMM_A2 Type : DDR3-Registered Size : 2048 MB Index : 2 Status : Ok Connector Name : DIMM_A3 Type : DDR3-Registered Size : 2048 MB Index : 3 Status : Critical Connector Name : DIMM_B1 Type : DDR3-Registered Size : 2048 MB Index : 4 Status : Ok Connector Name : DIMM_B2 Type : DDR3-Registered Size : 2048 MB Index : 5 Status : Ok Connector Name : DIMM_B3 Type : DDR3-Registered Size : 2048 MB the command free -m shows this, the server seems to be using more than 10GB of ram which would suggest it is trying to use the DIMM total used free shared buffers cached Mem: 12004 10766 1238 0 384 4809 -/+ buffers/cache: 5572 6432 Swap: 2047 0 2047 iostat output while problem is occuring avg-cpu: %user %nice %system %iowait %steal %idle 52.82 0.00 11.01 0.00 0.00 36.17 Device: tps Blk_read/s Blk_wrtn/s Blk_read Blk_wrtn sda 47.00 0.00 576.00 0 576 sda1 0.00 0.00 0.00 0 0 sda2 1.00 0.00 32.00 0 32 sda3 0.00 0.00 0.00 0 0 sda4 0.00 0.00 0.00 0 0 sda5 46.00 0.00 544.00 0 544 avg-cpu: %user %nice %system %iowait %steal %idle 53.12 0.00 7.81 0.00 0.00 39.06 Device: tps Blk_read/s Blk_wrtn/s Blk_read Blk_wrtn sda 49.00 0.00 592.00 0 592 sda1 0.00 0.00 0.00 0 0 sda2 0.00 0.00 0.00 0 0 sda3 0.00 0.00 0.00 0 0 sda4 0.00 0.00 0.00 0 0 sda5 49.00 0.00 592.00 0 592 avg-cpu: %user %nice %system %iowait %steal %idle 56.09 0.00 7.43 0.37 0.00 36.10 Device: tps Blk_read/s Blk_wrtn/s Blk_read Blk_wrtn sda 232.00 0.00 64520.00 0 64520 sda1 0.00 0.00 0.00 0 0 sda2 159.00 0.00 63728.00 0 63728 sda3 0.00 0.00 0.00 0 0 sda4 0.00 0.00 0.00 0 0 sda5 73.00 0.00 792.00 0 792 avg-cpu: %user %nice %system %iowait %steal %idle 52.18 0.00 9.24 0.06 0.00 38.51 Device: tps Blk_read/s Blk_wrtn/s Blk_read Blk_wrtn sda 49.00 0.00 600.00 0 600 sda1 0.00 0.00 0.00 0 0 sda2 0.00 0.00 0.00 0 0 sda3 0.00 0.00 0.00 0 0 sda4 0.00 0.00 0.00 0 0 sda5 49.00 0.00 600.00 0 600 avg-cpu: %user %nice %system %iowait %steal %idle 54.82 0.00 8.64 0.00 0.00 36.55 Device: tps Blk_read/s Blk_wrtn/s Blk_read Blk_wrtn sda 100.00 0.00 2168.00 0 2168 sda1 0.00 0.00 0.00 0 0 sda2 0.00 0.00 0.00 0 0 sda3 0.00 0.00 0.00 0 0 sda4 0.00 0.00 0.00 0 0 sda5 100.00 0.00 2168.00 0 2168 avg-cpu: %user %nice %system %iowait %steal %idle 54.78 0.00 6.75 0.00 0.00 38.48 Device: tps Blk_read/s Blk_wrtn/s Blk_read Blk_wrtn sda 84.00 0.00 896.00 0 896 sda1 0.00 0.00 0.00 0 0 sda2 0.00 0.00 0.00 0 0 sda3 0.00 0.00 0.00 0 0 sda4 0.00 0.00 0.00 0 0 sda5 84.00 0.00 896.00 0 896 avg-cpu: %user %nice %system %iowait %steal %idle 54.34 0.00 7.31 0.00 0.00 38.35 Device: tps Blk_read/s Blk_wrtn/s Blk_read Blk_wrtn sda 81.00 0.00 840.00 0 840 sda1 0.00 0.00 0.00 0 0 sda2 0.00 0.00 0.00 0 0 sda3 0.00 0.00 0.00 0 0 sda4 0.00 0.00 0.00 0 0 sda5 81.00 0.00 840.00 0 840 avg-cpu: %user %nice %system %iowait %steal %idle 55.18 0.00 5.81 0.44 0.00 38.58 Device: tps Blk_read/s Blk_wrtn/s Blk_read Blk_wrtn sda 317.00 0.00 105632.00 0 105632 sda1 0.00 0.00 0.00 0 0 sda2 224.00 0.00 104672.00 0 104672 sda3 0.00 0.00 0.00 0 0 sda4 0.00 0.00 0.00 0 0 sda5 93.00 0.00 960.00 0 960 avg-cpu: %user %nice %system %iowait %steal %idle 55.38 0.00 7.63 0.00 0.00 36.98 Device: tps Blk_read/s Blk_wrtn/s Blk_read Blk_wrtn sda 74.00 0.00 800.00 0 800 sda1 0.00 0.00 0.00 0 0 sda2 0.00 0.00 0.00 0 0 sda3 0.00 0.00 0.00 0 0 sda4 0.00 0.00 0.00 0 0 sda5 74.00 0.00 800.00 0 800 avg-cpu: %user %nice %system %iowait %steal %idle 56.43 0.00 7.80 0.00 0.00 35.77 Device: tps Blk_read/s Blk_wrtn/s Blk_read Blk_wrtn sda 72.00 0.00 784.00 0 784 sda1 0.00 0.00 0.00 0 0 sda2 0.00 0.00 0.00 0 0 sda3 0.00 0.00 0.00 0 0 sda4 0.00 0.00 0.00 0 0 sda5 72.00 0.00 784.00 0 784 avg-cpu: %user %nice %system %iowait %steal %idle 54.87 0.00 6.49 0.00 0.00 38.64 Device: tps Blk_read/s Blk_wrtn/s Blk_read Blk_wrtn sda 80.20 0.00 855.45 0 864 sda1 0.00 0.00 0.00 0 0 sda2 0.00 0.00 0.00 0 0 sda3 0.00 0.00 0.00 0 0 sda4 0.00 0.00 0.00 0 0 sda5 80.20 0.00 855.45 0 864 avg-cpu: %user %nice %system %iowait %steal %idle 57.22 0.00 5.69 0.00 0.00 37.09 Device: tps Blk_read/s Blk_wrtn/s Blk_read Blk_wrtn sda 33.00 0.00 432.00 0 432 sda1 0.00 0.00 0.00 0 0 sda2 0.00 0.00 0.00 0 0 sda3 0.00 0.00 0.00 0 0 sda4 0.00 0.00 0.00 0 0 sda5 33.00 0.00 432.00 0 432 avg-cpu: %user %nice %system %iowait %steal %idle 56.03 0.00 7.93 0.00 0.00 36.04 Device: tps Blk_read/s Blk_wrtn/s Blk_read Blk_wrtn sda 41.00 0.00 560.00 0 560 sda1 0.00 0.00 0.00 0 0 sda2 2.00 0.00 88.00 0 88 sda3 0.00 0.00 0.00 0 0 sda4 0.00 0.00 0.00 0 0 sda5 39.00 0.00 472.00 0 472 avg-cpu: %user %nice %system %iowait %steal %idle 55.78 0.00 5.13 0.00 0.00 39.09 Device: tps Blk_read/s Blk_wrtn/s Blk_read Blk_wrtn sda 29.00 0.00 392.00 0 392 sda1 0.00 0.00 0.00 0 0 sda2 0.00 0.00 0.00 0 0 sda3 0.00 0.00 0.00 0 0 sda4 0.00 0.00 0.00 0 0 sda5 29.00 0.00 392.00 0 392 avg-cpu: %user %nice %system %iowait %steal %idle 53.68 0.00 8.30 0.06 0.00 37.95 Device: tps Blk_read/s Blk_wrtn/s Blk_read Blk_wrtn sda 78.00 0.00 4280.00 0 4280 sda1 0.00 0.00 0.00 0 0 sda2 0.00 0.00 0.00 0 0 sda3 0.00 0.00 0.00 0 0 sda4 0.00 0.00 0.00 0 0 sda5 78.00 0.00 4280.00 0 4280

    Read the article

  • Small web server hardware advice

    - by Dmitri
    We need to build a new web server for our organization. We have around 100 hundred small traffic web sites, so our hardware requirements are not too tough. We run CentOS 6, Varnish+Apache, PHP, MySQL, Typo3 CMS for most of websites. Here's a hardware we want to buy: SuperMicro X9SCA-F-O (we need to have a remote management capability) (or better X9SCM-F?) Intel Xeon E3-1220 v2 2*4Gb DDR-III 1600MHz Kingston ECC (KVR16E11/4) (currently we have 4gb, and it feels like enough, so no reason for 16gb yet). Procase EB140-B-0 (1 unit) PSU 350W Procase MG1350, Active PFC We already have: Intel 335 120GB SSD (for OS, databases and important websites). 2*2tb WD Green RAID1 (for other data and backups). Does it look like a reasonable choice for our needs? Any issues with hardware compatibility? Any other notes?

    Read the article

  • Is 850W SMPS enough for the below Config?

    - by bali208
    We are planing to assemble a file server of the following configuration. 1) Intel S2400SC2 Motherboard. 2) Xeon 2407 Processor x 2 (Dual Processors) 3) 8gb x 8 ECC DDR3 RAM 4) One 2 TB Seagate HDD. 5) 8 cabinet fans fitted for NZXT Switch 810 Cabinet. Our question is is CoolerMaster 850 Watts power supply enough for our machine? Or we have to put 1050 Watts power Supply? Please suggest the best Brand and Wattage of SMPS we have to buy for our system. Thank you.

    Read the article

  • Separating user resources - Windows Server 2008 (Terminal Server)

    - by Christopher Wilson
    At the moment I am running a Windows Terminal Server 2008 for around 10 clients that use the server to run programs and access data. Is there anyway to separate the resources of each user so that they do not impact each other in terms of resources. User 1: Opens program User 2: Notices slow down I have looked into using Windows System Resource Manager but do not know if it provides what I need and if there are any other 3rd party tools that also provide this functionality. Any answer is appreciated. Server Specs: HP ProLiant ML110 G7 Processor: Intel® Xeon® E3-1220 (4 core, 3.1 GHz, 8MB, 80W, 1333/t) RAM: 12GB DDR3 ECC 1TB HDD

    Read the article

  • Will this increase my VPS failing rate ?

    - by Spencer Lim
    Will this increase my Virtual private Server failing rate if i :- install Microsoft Window Server 2008 Enterprise install SQL server enterprise 2008 install IIS 7.5 install ASP.Net Mvc 2 install Microsoft Exchange install Team foundation server on one mini VPS with specification of DELL Poweredge R710 shared plan DDR3 ECC RAMs 16GB and -- 1GB for this VPS using DELL PERC 6i raid controller (this thing alone about 1.5k-2k) and the SAS HDD (15K RPM) (146GB) -- 33GB to this VPS each hdd is freaking fast over 300MB read / write possible with proper tuning the motherboard is a DELL and it has twin redundant PSU (870watt 85%eff) its running on Intel Xeon 5502 (Quad Core) x2 so about 8 physical proc (fairly share) is there any ruler for this about one VPS can only install what what what service ? Thx for reply

    Read the article

  • setting up/installing/configuring nginx LEMP stack on fresh VPS server

    - by Grant Tailor
    I need some help in settingup/installing and configuring nginx LEMP stack on a fresh new VPS I have. The specs of the CentOS 5.7 VPS are 2GB DDR3 ECC RAM(4GB burst), 1 core 1.5Ghz(3Ghz burst) and 100GB RAID 10 storage, unmetered bandwidth @ 100Mpbs all for a whopping $25/month(unbeatable, yeah I know :) Anyways I have followed this LEMP (will also need MySQL and PHP) stack guide on linode http://library.linode.com/lemp-guides/centos-5 but basically what I want is to be able to host multiple website on this webserver after everything is setup. I am used to using DirectAdmin control panel on other server and want to have things setup so I can host multiple websites - mostly wordpress and drupal themes. Lets say 10 websites on this nginx web server. So can someone please help me on what I need to do to take "full" advantage of nginx power and performance, while been able to easily manage these multiple websites (wordpress and drupal themes)?

    Read the article

  • What are the quality metrics for RAM?

    - by Hi-Tech KitKat Android
    I have searched RAM and i found there are given some specification for the same capacity RAM, What are the difference and performance comparison between these? Like RAM1 General Brand Transcend Memory Type 2 GB (8 x 128 MB) DDR2 DIMM Memory Standard DDR2-800/PC-6400 Compatible Device PC Pins 240-pin Burst Length 4, 8 Buffered/Unbuffered Unbuffered Memory Memory Clock 400 MHz Technology DDR2 SDRAM Memory CAS Latency 4, 5, 6 RAM 2 General Brand Transcend Memory Type 2 GB (8 x 128 MB) DDR2 DIMM Memory Standard DDR2-667/PC2-5300 Compatible Device PC Pins 240-pin Burst Length 4, 8 Buffered/Unbuffered Unbuffered Memory Memory Clock 333 MHz Technology DDR2 SDRAM Memory CAS Latency 3, 4, 5 RAM3 General Brand Kingston Memory Type 2 GB (64 x 256 MB) 800 MHz DDR2 DIMM Compatible Device PC Pins 240-pin Error Check Non-ECC Buffered/Unbuffered Unbuffered Memory Memory Clock 200 MHz Technology DDR2 SDRAM Memory CAS Latency 6 What are the affect of the following Memory Type(given as 8 x 128 MB) Memory Clock (given in MHz) CAS Latency (given as 4,5,6) my Requirement is 2 GB DDR2 Type Desktop Please help

    Read the article

  • Reliability of S.M.A.R.T.?

    - by Mark
    I've been using ActiveSmart to monitor my hard-drives health for a few weeks now, and its telling me my brand new 1.5 TB hard-drive is half-dead already. About on-par with one of my hard-drives which I know is at least half dead because I've been having some read errors and heard ticking noises. Now I haven't actually noticed any problems with my 1.5 TB drive; should I be concerned that it's going to crap out on me too? Or could ActiveSmart be giving a mis-diagnosis because I use it a lot or something (I've used up 795 GB in the 2 and a half weeks I've had it). The events that ActiveSmart has been catching is "Hardware ECC recovered". Maybe these new fangled super big hard-drives somehow rely on ECCs to squeeze out the extra space, but this isn't actually a cause for concern?

    Read the article

  • Server reboots every 4.5-5.5 minutes...

    - by Andy
    Hi, I've recently installed a server in colocation, and my server is rebooting every 4.5-5.5 minutes. Regardless of the OS I run, it reboots. I have all ECC memory in the server, so it should correct errors if there is a bad bit in the memory, right? It's weird because it always happens about 4.5-5.5 minutes after bootup. My motherboard is a Supermicro X8DTL-iF. I read on a blog that another person had the problem, and supermicro recommended to do a BIOS update. Is this the right course of action?

    Read the article

  • HP DL160 G6 memory PC3-10600R vs PC3-10600E

    - by Jeremy Hajek
    I am using a HP DL 160 G6 server that according to specs takes PC3 Registered or Unbuffered. When I combine the two types of memory below the system will not POST. When I use just the first type of memory listed the system will POST. I have two pieces of HP memory that came with the server labeled PC3-10600E-9-10-E0 and then I have some Crucial memory labeled PC3-10600R-9-10-B0 I wager that the R means Registered memory and the E means ECC - then shouldn't the crucial memory boot with the system according to the HP specs? Or does the E mean it is Unbuffered and therefore I shouldn't mix and match as according to this HP memory config doc?

    Read the article

  • How to diagnose RAM?

    - by x-man
    I have a java process that is aborted after a while with SIGSEGV. It started to happen after I upgraded the server with more RAM. Having tested on different JVMs I suspect it might be a hardware problem. But no problem was detected by memtest86. So, what else can I do to detect the source of the problem is? Should I take the RAM modules one by one to detect the faulty module? The server is running on 64bit OpenSuse11.3. The memory is not an ECC one it seems. I have a kit of this (3*4GB * 2 = 24GB): http://www.kingston.com/datasheets/KHX1600C9S3K2_8GX.pdf

    Read the article

  • Iozone: sensible settings for a server with lots of RAM

    - by Frank Brenner
    I have just acquired a server with: 2x quadcore Xeons 48G ECC RAM 5x 160GB SSDs on an LSI 9260-8i Before deploying the target platform, I'd like to collect as much benchmark data as possible, testing I/O with hardware RAID in various configurations, ZFS zRAID, as well as I/O performance on vSphere and with KVM virtualization. In order to see real disk I/O performance without cache effects, I tried running Iozone with a maximum file of more than twice the physical RAM as recommended in the documentation, so: iozone -a -g100G However, as one might expect, this takes far too long to be practicable. (I stopped the run after seven hours..) I'd like to reduce the range of record and file sizes to values that might reflect realistic performance for an application server, hopefully getting the run times to under an hour or so. Any ideas? Thanks.

    Read the article

  • Using an Internal HDD as an External HDD also or an External HDD for installing SAP ?

    - by Asterix
    Is it possible and advisable to use an Internal Hard Drive as an External Hard drive also. I wanted to install SAP ECC 6 on my system which has only 250 GB but atleast 300 GB is required.I wanted to buy an External Drive first, then I heard loading SAP on an External would make it extremely slow. I'll be using it only as a beginer so even if it is a little slow i don't mind. Is it feasible to run such a big application from an External Hard disk ? So can i purchase a 500 or 1 TB Internal Hard disk and use it as an External too by fitting it with the necessary USB 3.0 Hard drive cases and cables ? or should i purchase a External and load SAP onto it ? Thank you.

    Read the article

  • PC3200 RAM in Older Computer?

    - by skaz
    Hello all, I am inheriting a Dell Dimension 8200, but it needs RAM to get up and running. I have PC3200 sticks lying around, but I am not sure how to go about figuring out if the RAM is compatible, as RAM has always confused me. Here is the Dell Dimension 8200 Tech Specs: http://support.dell.com/support/edocs/systems/dim8200/specs.htm For RAM, it says: Memory type PC800 (non-ECC) I don't know if that is just the kind that comes with it, and I can put in PC3200 (I think, if it worked, this would run at the lower rating? Is that true?), or if that means only PC800 is compatible. Any help would be appreciated.

    Read the article

  • Fastest Memory (within reason) for a MotherBoard [on hold]

    - by sampson
    I was wondering if it would be OK to use DDR3 3000 memory with Asus Maximus VI Impact MotherBoard, Intel® Core™ i3-4130T Processor and Steamcom's FC8 case The purpose of this machine is for a HTPC (Home Theater Personal Computer) system, only, no gaming. The case is fan less as is the CPU cooling system. Also, would it be worth it, heat wise, to go past the 1600 memory type? I mean, would DDR 3000 make the box that much faster to make it worthwhile? The Processor has a TDP rating of 35 W. The memory specifications for the processor are: Memory Specifications Max Memory Size (dependent on memory type) 32 GB Memory Types DDR3-1333/1600 # of Memory Channels 2 Max Memory Bandwidth 25.6 GB/s ECC Memory Supported ‡ Yes The FC8 case's heat displacement system is rated at 95 W TDP

    Read the article

  • DVD RW+ Not showing up

    - by Manywa R.
    I'm running Ubuntu 12.10 on a Toshiba Satellite Pro A120 and my built in DVD Drive is not opening any cd/dvd/dvd rw that am trying to play on them. the drive seems to be mounted and recongnized: Output of sudo lshw: ... *-cdrom description: DVD-RAM writer product: DVD-RAM UJ-841S vendor: MATSHITA physical id: 1 bus info: scsi@1:0.0.0 logical name: /dev/cdrom logical name: /dev/cdrw logical name: /dev/dvd logical name: /dev/dvdrw logical name: /dev/sr0 version: 1.40 capabilities: removable audio cd-r cd-rw dvd dvd-r dvd-ram configuration: ansiversion=5 status=ready *-medium physical id: 0 logical name: /dev/cdrom and the disk seems to start but hang with the dvd drive LED solid amber.... the output of jun@jun-Satellite-Pro-A120:~$ dmesg | grep "sr0" [679396.184901] sr 1:0:0:0: [sr0] Unhandled sense code [679396.184910] sr 1:0:0:0: [sr0] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE [679396.184920] sr 1:0:0:0: [sr0] Sense Key : Hardware Error [current] [679396.184931] sr 1:0:0:0: [sr0] Add. Sense: Id CRC or ECC error [679396.184942] sr 1:0:0:0: [sr0] CDB: Read(10): 28 00 00 00 00 00 00 00 08 00 [679396.184965] end_request: I/O error, dev sr0, sector 0 [679396.184975] Buffer I/O error on device sr0, logical block 0 [679396.184984] Buffer I/O error on device sr0, logical block 1 [679396.184990] Buffer I/O error on device sr0, logical block 2 [679396.184996] Buffer I/O error on device sr0, logical block 3 [679396.185002] Buffer I/O error on device sr0, logical block 4 [679396.185008] Buffer I/O error on device sr0, logical block 5 [679396.185014] Buffer I/O error on device sr0, logical block 6 [679396.185020] Buffer I/O error on device sr0, logical block 7 [679396.185031] Buffer I/O error on device sr0, logical block 8 [679396.185038] Buffer I/O error on device sr0, logical block 9 [679396.185070] sr 1:0:0:0: [sr0] unaligned transfer [679396.185108] sr 1:0:0:0: [sr0] unaligned transfer Can someone help me through this? tired of moving around with an external dvd drive. Thanks

    Read the article

  • My cpus are powered down periodically

    - by mgiammarco
    I post here because I am using Ubuntu but this is probably an hardware problem. Since I bought my new setup with AMD Athlon(tm) II X4 635 Processor and asus m4a89td pro/usb3 motherboard with ecc ram I have stuttering on videos. I was using ubuntu 11.10 now ubuntu 12.10. Looking at syslog I have found that periodically (I notice only on videos but it happens always) this thing happens: Mar 6 23:36:42 virtual1 kernel: [28564.375548] smpboot: CPU 1 is now offline Mar 6 23:36:42 virtual1 kernel: [28564.380751] smpboot: CPU 2 is now offline Mar 6 23:36:42 virtual1 kernel: [28564.394947] smpboot: CPU 3 is now offline Mar 6 23:36:48 virtual1 kernel: [28569.917021] smpboot: Booting Node 0 Processor 1 APIC 0x1 Mar 6 23:36:48 virtual1 kernel: [28569.928015] LVT offset 0 assigned for vector 0xf9 Mar 6 23:36:48 virtual1 kernel: [28569.928372] [Firmware Bug]: cpu 1, try to use APIC500 (LVT offset 0) for vector 0x400, but the register is already in use for vector 0xf9 on another cpu Mar 6 23:36:48 virtual1 kernel: [28569.928378] perf: IBS APIC setup failed on cpu #1 Mar 6 23:36:48 virtual1 kernel: [28569.931305] process: Switch to broadcast mode on CPU1 Mar 6 23:36:48 virtual1 kernel: [28569.934255] smpboot: Booting Node 0 Processor 2 APIC 0x2 Mar 6 23:36:48 virtual1 kernel: [28569.945554] [Firmware Bug]: cpu 2, try to use APIC500 (LVT offset 0) for vector 0x400, but the register is already in use for vector 0xf9 on another cpu Mar 6 23:36:48 virtual1 kernel: [28569.945558] perf: IBS APIC setup failed on cpu #2 Mar 6 23:36:48 virtual1 kernel: [28569.948124] process: Switch to broadcast mode on CPU2 Mar 6 23:36:48 virtual1 kernel: [28569.949644] smpboot: Booting Node 0 Processor 3 APIC 0x3 Mar 6 23:36:48 virtual1 kernel: [28569.960838] [Firmware Bug]: cpu 3, try to use APIC500 (LVT offset 0) for vector 0x400, but the register is already in use for vector 0xf9 on another cpu Mar 6 23:36:48 virtual1 kernel: [28569.960840] perf: IBS APIC setup failed on cpu #3 Mar 6 23:36:48 virtual1 kernel: [28569.962953] process: Switch to broadcast mode on CPU3 I have: updated bios; tried all (really) bios options; changed ram; changed psu and cpu cooler; tried 3.8.1 kernel. What can I do now? Please help me! Thanks, Mario

    Read the article

  • MVC with cocoa/objective-c

    - by Leonardo
    Hi all, I have a strong j2ee background, and I am trying to move to objective-c for some desktop/iphone programming. I used many java web frameworks with mvc in mind, spring and struts ecc... so I am used to have servlet or controller which pass attributes to jsp pages, which is the view. In jsp pages with jstl you can call this attribute and render to video. In this way controller and view are (in theory) clearly separated. With xcode, I can easily recognize the controller and the view built with IBuilder. All the tutorial I found, shown the controller which go and change directly labels or text fields. So my two questions: seems to me that there's no separation between the two (controller and view), where I am wrong in that ? is there a way for a controller to pack all objects in a kind of context in a j2ee way and have the view read that context ? thanks Leonardo

    Read the article

  • NSDictionary with specific property of plist

    - by Leonardo
    Hi, I have a plist with key values. Each key represent a language, let's say 'it' 'en' ....ecc The value of each key is another key/value(=array) set. At startup I would like to create a dictionary by reading only a specific key. Let's say the locale of my iphone is 'it', then the init method would only parse it key, because the only way I found by now is to make a dictionary from the whole plist file and then another dictionary. But I can imagine this can become quite cpu consuming if I add more language in the future. thanks Leonardo

    Read the article

  • Strange Recurrent Excessive I/O Wait

    - by Chris
    I know quite well that I/O wait has been discussed multiple times on this site, but all the other topics seem to cover constant I/O latency, while the I/O problem we need to solve on our server occurs at irregular (short) intervals, but is ever-present with massive spikes of up to 20k ms a-wait and service times of 2 seconds. The disk affected is /dev/sdb (Seagate Barracuda, for details see below). A typical iostat -x output would at times look like this, which is an extreme sample but by no means rare: iostat (Oct 6, 2013) tps rd_sec/s wr_sec/s avgrq-sz avgqu-sz await svctm %util 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 16.00 0.00 156.00 9.75 21.89 288.12 36.00 57.60 5.50 0.00 44.00 8.00 48.79 2194.18 181.82 100.00 2.00 0.00 16.00 8.00 46.49 3397.00 500.00 100.00 4.50 0.00 40.00 8.89 43.73 5581.78 222.22 100.00 14.50 0.00 148.00 10.21 13.76 5909.24 68.97 100.00 1.50 0.00 12.00 8.00 8.57 7150.67 666.67 100.00 0.50 0.00 4.00 8.00 6.31 10168.00 2000.00 100.00 2.00 0.00 16.00 8.00 5.27 11001.00 500.00 100.00 0.50 0.00 4.00 8.00 2.96 17080.00 2000.00 100.00 34.00 0.00 1324.00 9.88 1.32 137.84 4.45 59.60 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 22.00 44.00 204.00 11.27 0.01 0.27 0.27 0.60 Let me provide you with some more information regarding the hardware. It's a Dell 1950 III box with Debian as OS where uname -a reports the following: Linux xx 2.6.32-5-amd64 #1 SMP Fri Feb 15 15:39:52 UTC 2013 x86_64 GNU/Linux The machine is a dedicated server that hosts an online game without any databases or I/O heavy applications running. The core application consumes about 0.8 of the 8 GBytes RAM, and the average CPU load is relatively low. The game itself, however, reacts rather sensitive towards I/O latency and thus our players experience massive ingame lag, which we would like to address as soon as possible. iostat: avg-cpu: %user %nice %system %iowait %steal %idle 1.77 0.01 1.05 1.59 0.00 95.58 Device: tps Blk_read/s Blk_wrtn/s Blk_read Blk_wrtn sdb 13.16 25.42 135.12 504701011 2682640656 sda 1.52 0.74 20.63 14644533 409684488 Uptime is: 19:26:26 up 229 days, 17:26, 4 users, load average: 0.36, 0.37, 0.32 Harddisk controller: 01:00.0 RAID bus controller: LSI Logic / Symbios Logic MegaRAID SAS 1078 (rev 04) Harddisks: Array 1, RAID-1, 2x Seagate Cheetah 15K.5 73 GB SAS Array 2, RAID-1, 2x Seagate ST3500620SS Barracuda ES.2 500GB 16MB 7200RPM SAS Partition information from df: Filesystem 1K-blocks Used Available Use% Mounted on /dev/sdb1 480191156 30715200 425083668 7% /home /dev/sda2 7692908 437436 6864692 6% / /dev/sda5 15377820 1398916 13197748 10% /usr /dev/sda6 39159724 19158340 18012140 52% /var Some more data samples generated with iostat -dx sdb 1 (Oct 11, 2013) Device: rrqm/s wrqm/s r/s w/s rsec/s wsec/s avgrq-sz avgqu-sz await svctm %util sdb 0.00 15.00 0.00 70.00 0.00 656.00 9.37 4.50 1.83 4.80 33.60 sdb 0.00 0.00 0.00 2.00 0.00 16.00 8.00 12.00 836.00 500.00 100.00 sdb 0.00 0.00 0.00 3.00 0.00 32.00 10.67 9.96 1990.67 333.33 100.00 sdb 0.00 0.00 0.00 4.00 0.00 40.00 10.00 6.96 3075.00 250.00 100.00 sdb 0.00 0.00 0.00 0.00 0.00 0.00 0.00 4.00 0.00 0.00 100.00 sdb 0.00 0.00 0.00 2.00 0.00 16.00 8.00 2.62 4648.00 500.00 100.00 sdb 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2.00 0.00 0.00 100.00 sdb 0.00 0.00 0.00 1.00 0.00 16.00 16.00 1.69 7024.00 1000.00 100.00 sdb 0.00 74.00 0.00 124.00 0.00 1584.00 12.77 1.09 67.94 6.94 86.00 Characteristic charts generated with rrdtool can be found here: iostat plot 1, 24 min interval: http://imageshack.us/photo/my-images/600/yqm3.png/ iostat plot 2, 120 min interval: http://imageshack.us/photo/my-images/407/griw.png/ As we have a rather large cache of 5.5 GBytes, we thought it might be a good idea to test if the I/O wait spikes would perhaps be caused by cache miss events. Therefore, we did a sync and then this to flush the cache and buffers: echo 3 > /proc/sys/vm/drop_caches and directly afterwards the I/O wait and service times virtually went through the roof, and everything on the machine felt like slow motion. During the next few hours the latency recovered and everything was as before - small to medium lags in short, unpredictable intervals. Now my question is: does anybody have any idea what might cause this annoying behaviour? Is it the first indication of the disk array or the raid controller dying, or something that can be easily mended by rebooting? (At the moment we're very reluctant to do this, however, because we're afraid that the disks might not come back up again.) Any help is greatly appreciated. Thanks in advance, Chris. Edited to add: we do see one or two processes go to 'D' state in top, one of which seems to be kjournald rather frequently. If I'm not mistaken, however, this does not indicate the processes causing the latency, but rather those affected by it - correct me if I'm wrong. Does the information about uninterruptibly sleeping processes help us in any way to address the problem? @Andy Shinn requested smartctl data, here it is: smartctl -a -d megaraid,2 /dev/sdb yields: smartctl 5.40 2010-07-12 r3124 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net Device: SEAGATE ST3500620SS Version: MS05 Serial number: Device type: disk Transport protocol: SAS Local Time is: Mon Oct 14 20:37:13 2013 CEST Device supports SMART and is Enabled Temperature Warning Disabled or Not Supported SMART Health Status: OK Current Drive Temperature: 20 C Drive Trip Temperature: 68 C Elements in grown defect list: 0 Vendor (Seagate) cache information Blocks sent to initiator = 1236631092 Blocks received from initiator = 1097862364 Blocks read from cache and sent to initiator = 1383620256 Number of read and write commands whose size <= segment size = 531295338 Number of read and write commands whose size > segment size = 51986460 Vendor (Seagate/Hitachi) factory information number of hours powered up = 36556.93 number of minutes until next internal SMART test = 32 Error counter log: Errors Corrected by Total Correction Gigabytes Total ECC rereads/ errors algorithm processed uncorrected fast | delayed rewrites corrected invocations [10^9 bytes] errors read: 509271032 47 0 509271079 509271079 20981.423 0 write: 0 0 0 0 0 5022.039 0 verify: 1870931090 196 0 1870931286 1870931286 100558.708 0 Non-medium error count: 0 SMART Self-test log Num Test Status segment LifeTime LBA_first_err [SK ASC ASQ] Description number (hours) # 1 Background short Completed 16 36538 - [- - -] # 2 Background short Completed 16 36514 - [- - -] # 3 Background short Completed 16 36490 - [- - -] # 4 Background short Completed 16 36466 - [- - -] # 5 Background short Completed 16 36442 - [- - -] # 6 Background long Completed 16 36420 - [- - -] # 7 Background short Completed 16 36394 - [- - -] # 8 Background short Completed 16 36370 - [- - -] # 9 Background long Completed 16 36364 - [- - -] #10 Background short Completed 16 36361 - [- - -] #11 Background long Completed 16 2 - [- - -] #12 Background short Completed 16 0 - [- - -] Long (extended) Self Test duration: 6798 seconds [113.3 minutes] smartctl -a -d megaraid,3 /dev/sdb yields: smartctl 5.40 2010-07-12 r3124 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net Device: SEAGATE ST3500620SS Version: MS05 Serial number: Device type: disk Transport protocol: SAS Local Time is: Mon Oct 14 20:37:26 2013 CEST Device supports SMART and is Enabled Temperature Warning Disabled or Not Supported SMART Health Status: OK Current Drive Temperature: 19 C Drive Trip Temperature: 68 C Elements in grown defect list: 0 Vendor (Seagate) cache information Blocks sent to initiator = 288745640 Blocks received from initiator = 1097848399 Blocks read from cache and sent to initiator = 1304149705 Number of read and write commands whose size <= segment size = 527414694 Number of read and write commands whose size > segment size = 51986460 Vendor (Seagate/Hitachi) factory information number of hours powered up = 36596.83 number of minutes until next internal SMART test = 28 Error counter log: Errors Corrected by Total Correction Gigabytes Total ECC rereads/ errors algorithm processed uncorrected fast | delayed rewrites corrected invocations [10^9 bytes] errors read: 610862490 44 0 610862534 610862534 20470.133 0 write: 0 0 0 0 0 5022.480 0 verify: 2861227413 203 0 2861227616 2861227616 100872.443 0 Non-medium error count: 1 SMART Self-test log Num Test Status segment LifeTime LBA_first_err [SK ASC ASQ] Description number (hours) # 1 Background short Completed 16 36580 - [- - -] # 2 Background short Completed 16 36556 - [- - -] # 3 Background short Completed 16 36532 - [- - -] # 4 Background short Completed 16 36508 - [- - -] # 5 Background short Completed 16 36484 - [- - -] # 6 Background long Completed 16 36462 - [- - -] # 7 Background short Completed 16 36436 - [- - -] # 8 Background short Completed 16 36412 - [- - -] # 9 Background long Completed 16 36404 - [- - -] #10 Background short Completed 16 36401 - [- - -] #11 Background long Completed 16 2 - [- - -] #12 Background short Completed 16 0 - [- - -] Long (extended) Self Test duration: 6798 seconds [113.3 minutes]

    Read the article