Search Results

Search found 1315 results on 53 pages for 'pci e'.

Page 4/53 | < Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >

  • How do I make changes to /proc/acpi/wakeup permanent?

    - by Jolan
    I had a problem with my Ubuntu 12.04 waking up immediately after going into suspend. I solved the problem by changing the settings in /proc/acpi/wakeup, as suggested in this question: How do I prevent immediate wake up from suspend?. After changing the settings, the system goes flawlessly into suspend and stays suspended, but after I wake it back up, the settings in /proc/acpi/wakeup are different from what I set them to. Before going to suspend: cat /proc/acpi/wakeup Device S-state Status Sysfs node SMB0 S4 *disabled pci:0000:00:03.2 PBB0 S4 *disabled pci:0000:00:09.0 HDAC S4 *disabled pci:0000:00:08.0 XVR0 S4 *disabled pci:0000:00:0c.0 XVR1 S4 *disabled P0P5 S4 *disabled P0P6 S4 *disabled pci:0000:00:15.0 GLAN S4 *enabled pci:0000:03:00.0 P0P7 S4 *disabled pci:0000:00:16.0 P0P8 S4 *disabled P0P9 S4 *disabled USB0 S3 *disabled pci:0000:00:04.0 USB2 S3 *disabled pci:0000:00:04.1 US15 S3 *disabled pci:0000:00:06.0 US12 S3 *disabled pci:0000:00:06.1 PWRB S4 *enabled SLPB S4 *enabled I tell the system to suspend, and it works as it should. But later after waking it up, the settings are changed to either: USB0 S3 *disabled pci:0000:00:04.0 USB2 S3 *enabled pci:0000:00:04.1 US15 S3 *disabled pci:0000:00:06.0 US12 S3 *enabled pci:0000:00:06.1 or USB0 S3 *enabled pci:0000:00:04.0 USB2 S3 *enabled pci:0000:00:04.1 US15 S3 *enabled pci:0000:00:06.0 US12 S3 *enabled pci:0000:00:06.1 Any ideas? Thank you for your response. Unfortunately it did not solve my problem. all of /sys/bus/usb/devices/usb1/power/wakeup /sys/bus/usb/devices/usb2/power/wakeup /sys/bus/usb/devices/usb3/power/wakeup /sys/bus/usb/devices/usb4/power/wakeup as well as /sys/bus/usb/devices/3-1/power/wakeup are set to disabled, and the notebook still wakes up by itself right after going to sleep. The only thing it seems to react to are the settings in /proc/acpi/wakeup, which keep changing (resetting) every time i power off/restart my notebook.

    Read the article

  • Why would 70-persistent-net.rules have no effect?

    - by Wes Felter
    I've got a saucy server with a lot of NICs and they end up with weird names like "rename19". I know interface names can be changed by modifying the /etc/udev/rules.d/70-persistent-net.rules file. The first clue that something is wrong is that that file did not exist even though it's supposed to be created automatically. So I decided to write my own based on advice from Linux From Scratch: ACTION=="add", SUBSYSTEM=="net", BUS=="pci", KERNELS=="0000:06:00.0", NAME="eth0" ACTION=="add", SUBSYSTEM=="net", BUS=="pci", KERNELS=="0000:06:00.1", NAME="eth1" ACTION=="add", SUBSYSTEM=="net", BUS=="pci", KERNELS=="0000:06:00.2", NAME="eth2" ACTION=="add", SUBSYSTEM=="net", BUS=="pci", KERNELS=="0000:06:00.3", NAME="eth3" ACTION=="add", SUBSYSTEM=="net", BUS=="pci", KERNELS=="0000:0c:00.0", NAME="mezz0" ACTION=="add", SUBSYSTEM=="net", BUS=="pci", KERNELS=="0000:0c:00.1", NAME="mezz1" ACTION=="add", SUBSYSTEM=="net", BUS=="pci", KERNELS=="0000:1b:00.0", NAME="slot1a" ACTION=="add", SUBSYSTEM=="net", BUS=="pci", KERNELS=="0000:1b:00.1", NAME="slot1b" ACTION=="add", SUBSYSTEM=="net", BUS=="pci", KERNELS=="0000:20:00.0", NAME="slot2a" ACTION=="add", SUBSYSTEM=="net", BUS=="pci", KERNELS=="0000:20:00.1", NAME="slot2b" ACTION=="add", SUBSYSTEM=="net", BUS=="pci", KERNELS=="0000:11:00.0", NAME="slot3a" ACTION=="add", SUBSYSTEM=="net", BUS=="pci", KERNELS=="0000:11:00.1", NAME="slot3b" ACTION=="add", SUBSYSTEM=="net", BUS=="pci", KERNELS=="0000:8b:00.0", NAME="slot4a" ACTION=="add", SUBSYSTEM=="net", BUS=="pci", KERNELS=="0000:8b:00.1", NAME="slot4b" ACTION=="add", SUBSYSTEM=="net", BUS=="pci", KERNELS=="0000:90:00.0", NAME="slot5a" ACTION=="add", SUBSYSTEM=="net", BUS=="pci", KERNELS=="0000:90:00.1", NAME="slot5b" ACTION=="add", SUBSYSTEM=="net", BUS=="pci", KERNELS=="0000:95:00.0", NAME="slot6a" ACTION=="add", SUBSYSTEM=="net", BUS=="pci", KERNELS=="0000:95:00.1", NAME="slot6b" (I'm matching on PCI IDs instead of MAC addresses because I have multiple identical machines that I want to apply this configuration to.) After rebooting, nothing has changed. It's like these rules aren't even being read. There's not much going on in dmesg either: $ dmesg | grep udev [ 3.196629] systemd-udevd[323]: starting version 204 [ 6.719140] systemd-udevd[550]: starting version 204 [ 38.695050] init: udev-fallback-graphics main process (1658) terminated with status 1

    Read the article

  • Davicom Semiconductor, Inc. 21x4x DEC-Tulip not detected by Wireshark but IP operational

    - by deepsix86
    Recently flipped to Ubuntu 11.10 on a Dell 4300 (Intel). Getting IP address and no issues (ping/surf) but Wireshark unable to detect eth0 interface. I see references in forums to blacklist tulip but looks like I am running dmfe. Not sure if the blacklist is required and where to go from here. Maybe Driver update? Got a little lost looking in that area. Some h/w details below (IP/MAC/HOSTNAME removed) Linux xxxxxx 3.0.0-17-generic #30-Ubuntu SMP Thu Mar 8 17:34:21 UTC 2012 i686 i686 i386 GNU/Linux network-admin (HOSTS TAB) does not list eth0, only loopback and bunch of IPv6 interfaces ifconfig eth0 Link encap:Ethernet HWaddr xxxxxxxx inet addr:192.168.x.xx Bcast:192.168.2.255 Mask:255.255.255.0 inet6 addr: xxxxxxxxxxx 64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:36662 errors:0 dropped:1 overruns:0 frame:0 TX packets:24975 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:42115779 (42.1 MB) TX bytes:3056435 (3.0 MB) Interrupt:18 Base address:0xe800 lspci 02:09.0 Ethernet controller: Davicom Semiconductor, Inc. 21x4x DEC-Tulip compatible 10/100 Ethernet (rev 31) Subsystem: Device 4554:434e Flags: bus master, medium devsel, latency 64, IRQ 18 I/O ports at e800 [size=256] Memory at fe1ffc00 (32-bit, non-prefetchable) [size=256] Expansion ROM at fe200000 [disabled] [size=256K] Capabilities: [50] Power Management version 2 Kernel driver in use: dmfe Kernel modules: dmfe hwinfo --netcard 20: PCI 209.0: 0200 Ethernet controller [Created at pci.318] Unique ID: rBUF.0NgK5ZS9c0D Parent ID: 6NW+.siohrLUzzI4 SysFS ID: /devices/pci0000:00/0000:00:1e.0/0000:02:09.0 SysFS BusID: 0000:02:09.0 Hardware Class: network Model: "Davicom 21x4x DEC-Tulip compatible 10/100 Ethernet" Vendor: pci 0x1282 "Davicom Semiconductor, Inc." Device: pci 0x9102 "21x4x DEC-Tulip compatible 10/100 Ethernet" SubVendor: pci 0x4554 SubDevice: pci 0x434e Revision: 0x31 Driver: "dmfe" Driver Modules: "dmfe" Device File: eth0 I/O Ports: 0xe800-0xe8ff (rw) Memory Range: 0xfe1ffc00-0xfe1ffcff (rw,non-prefetchable) Memory Range: 0xfe200000-0xfe23ffff (ro,non-prefetchable,disabled) IRQ: 18 (61379 events) HW Address: 00:08:a1:01:35:70 Link detected: yes Module Alias: "pci:v00001282d00009102sv00004554sd0000434Ebc02sc00i00" Driver Info #0: Driver Status: dmfe is active Driver Activation Cmd: "modprobe dmfe" Config Status: cfg=new, avail=yes, need=no, active=unknown Attached to: #11 (PCI bridge)

    Read the article

  • PCI X16 Video Card Expansion Question [closed]

    - by Jonathan
    Possible Duplicate: Will a PCI-E V2.0 Graphics Card work with a PCI-E V1.0 Motherboard? My HP Pavilion p6754y has a PCI Express x16 slot on it's motherboard, I want to put a video car with something higher than either NVIDIA 8800GTS 512MB or greater or ATI 3850 512MB or greater but the only video cards I can find with those specs are PCI Express 2.0 x16. Is the PCI Express 2.0 x16 compatible with the PCI Express x16 slot?

    Read the article

  • Second video card (PCI) under Windows 7

    - by dbkk101
    I'm trying to get an old PCI video card (Diamond Stealth 2500) along with a normal PCI-E video card. In BIOS, there is a setting to switch between PEG/PCI or PCI/PEG on startup (PEG is PCI-E Graphics). When I use PCI/PEG only the old PCI card works, when I use the other one, only the new PEG card works. In PEG/PCI mode, Windows 7 recognizes the card and shows it in Device Manager as Standard VGA adapter, but it shows a warning for the device ("This device cannot start. (Code 10)").

    Read the article

  • How is 'processing credit card data' defined (PCI)?

    - by Chris
    If i have a web application and i receive credit card data transmitted via a POST request by a web browser over HTTPS and instantly open a socket (SSL) to a remote PCI compilant card processor to forward the data and wait for a response, am i allowed to do that? or is this receiving the data with my application and forwarding it already subject of "processing credit card data"? if i create an iframe that is displayed in a client browser to enter cc data and this iframe posts the data via HTTPS to remote card processor (directly!) is this already a case of processing credit card data? even if my application code 'doesnt touch' the entered data with any event handlers? i'm interested in the definition "credit card data processing". when does it start to be a cc data processing application? can somebody maybe point me to that section in PCI-DSS standard that clearly defines when you start to 'be a processing application'? Thanks,

    Read the article

  • Bluetooth not found on BCM43228

    - by TK Kocheran
    I've got a Broadcom BCM43228 mPCIe card which came with my motherboard (ASUS ROG Maximus V Extreme, can't seem to find a link to what the card is) which is working great for WiFi right now, but I can't detect the Bluetooth hardware onboard. In Windows, I have full Bluetooth 4.0 support. $ lspci 00:00.0 Host bridge: Intel Corporation 2nd Generation Core Processor Family DRAM Controller (rev 09) 00:01.0 PCI bridge: Intel Corporation Xeon E3-1200/2nd Generation Core Processor Family PCI Express Root Port (rev 09) 00:14.0 USB controller: Intel Corporation Panther Point USB xHCI Host Controller (rev 04) 00:16.0 Communication controller: Intel Corporation Panther Point MEI Controller #1 (rev 04) 00:19.0 Ethernet controller: Intel Corporation 82579V Gigabit Network Connection (rev 04) 00:1a.0 USB controller: Intel Corporation Panther Point USB Enhanced Host Controller #2 (rev 04) 00:1b.0 Audio device: Intel Corporation Panther Point High Definition Audio Controller (rev 04) 00:1c.0 PCI bridge: Intel Corporation Panther Point PCI Express Root Port 1 (rev c4) 00:1c.4 PCI bridge: Intel Corporation Panther Point PCI Express Root Port 5 (rev c4) 00:1c.6 PCI bridge: Intel Corporation Panther Point PCI Express Root Port 7 (rev c4) 00:1c.7 PCI bridge: Intel Corporation Panther Point PCI Express Root Port 8 (rev c4) 00:1d.0 USB controller: Intel Corporation Panther Point USB Enhanced Host Controller #1 (rev 04) 00:1f.0 ISA bridge: Intel Corporation Panther Point LPC Controller (rev 04) 00:1f.2 SATA controller: Intel Corporation Panther Point 6 port SATA Controller [AHCI mode] (rev 04) 00:1f.3 SMBus: Intel Corporation Panther Point SMBus Controller (rev 04) 01:00.0 VGA compatible controller: NVIDIA Corporation Device 1189 (rev a1) 01:00.1 Audio device: NVIDIA Corporation Device 0e0a (rev a1) 0d:00.0 USB controller: ASMedia Technology Inc. ASM1042 SuperSpeed USB Host Controller 0e:00.0 PCI bridge: PLX Technology, Inc. PEX 8608 8-lane, 8-Port PCI Express Gen 2 (5.0 GT/s) Switch (rev ba) 0f:01.0 PCI bridge: PLX Technology, Inc. PEX 8608 8-lane, 8-Port PCI Express Gen 2 (5.0 GT/s) Switch (rev ba) 0f:04.0 PCI bridge: PLX Technology, Inc. PEX 8608 8-lane, 8-Port PCI Express Gen 2 (5.0 GT/s) Switch (rev ba) 0f:05.0 PCI bridge: PLX Technology, Inc. PEX 8608 8-lane, 8-Port PCI Express Gen 2 (5.0 GT/s) Switch (rev ba) 0f:06.0 PCI bridge: PLX Technology, Inc. PEX 8608 8-lane, 8-Port PCI Express Gen 2 (5.0 GT/s) Switch (rev ba) 0f:07.0 PCI bridge: PLX Technology, Inc. PEX 8608 8-lane, 8-Port PCI Express Gen 2 (5.0 GT/s) Switch (rev ba) 0f:08.0 PCI bridge: PLX Technology, Inc. PEX 8608 8-lane, 8-Port PCI Express Gen 2 (5.0 GT/s) Switch (rev ba) 0f:09.0 PCI bridge: PLX Technology, Inc. PEX 8608 8-lane, 8-Port PCI Express Gen 2 (5.0 GT/s) Switch (rev ba) 10:00.0 USB controller: ASMedia Technology Inc. ASM1042 SuperSpeed USB Host Controller 12:00.0 SATA controller: ASMedia Technology Inc. ASM1062 Serial ATA Controller (rev 01) 15:00.0 Network controller: Broadcom Corporation BCM43228 802.11a/b/g/n 17:00.0 SATA controller: ASMedia Technology Inc. ASM1062 Serial ATA Controller (rev 01) The key line seems to be: 15:00.0 Network controller: Broadcom Corporation BCM43228 802.11a/b/g/n If I try to detect the Bluetooth card, I don't see anything: $ hcitool dev Devices: rfkill list all: Output lspci: Output lsusb: Output I finally found the card with usb-devices: T: Bus=01 Lev=02 Prnt=02 Port=00 Cnt=01 Dev#= 3 Spd=12 MxCh= 0 D: Ver= 2.00 Cls=ff(vend.) Sub=01 Prot=01 MxPS=64 #Cfgs= 1 P: Vendor=0b05 ProdID=17b5 Rev=01.12 S: Manufacturer=Broadcom Corp S: Product=BCM20702A0 S: SerialNumber=############ C: #Ifs= 4 Cfg#= 1 Atr=e0 MxPwr=0mA I: If#= 0 Alt= 0 #EPs= 3 Cls=ff(vend.) Sub=01 Prot=01 Driver=(none) I: If#= 1 Alt= 0 #EPs= 2 Cls=ff(vend.) Sub=01 Prot=01 Driver=(none) I: If#= 2 Alt= 0 #EPs= 2 Cls=ff(vend.) Sub=ff Prot=ff Driver=(none) I: If#= 3 Alt= 0 #EPs= 0 Cls=fe(app. ) Sub=01 Prot=01 Driver=(none) I've heard that this card needs to have firmware injected into it in order to function. If that's the case, how do I do it?

    Read the article

  • Engineered Systems and PCI

    - by Joel Weise
    Oracle has a number of different engineered systems.  These are design to be highly integrated, optimized and secure systems.  The Exadata database engineered system and the Exalogic application engineered system are two good examples.  Often I am asked how these comply with different standards and regulations.  Exalogic is the Oracle engineered system that supports applications and the focus of today's blog.  First, we must recognize that as a collection of hardware and software, we cannot simply state that Exalogic is "compliant" with PCI DSS.  This is because Exalogic must be implemented within the context of one's existing IT infrastructure, the security features of that infrastructure, the governance framework that exists, security policies, operational procedures, and other factors.  What we can say though, is that Exalogic has been designed with various security capabilities that can be utilized to support compliance to PCI DSS as well as other standards and regulations (e.g., NIST and HIPAA).  Given that, Exalogic can be an excellant platform for running PCI related payment applications.  Coalfire Systems, a leading QSA in the US, has evaluated Exalogic against PCI DSS and supports this position.  Their evaluation can be found here: Exalogic and PCI Compliance. I hope you find it useful. 

    Read the article

  • Wireless Problem on Acer Aspire 5610z

    - by Ugur Can Yalaki
    I installed ubuntu 12.04 on my machine, but I can't get wireless connection to work. My computer is Acer Aspire 5610z. I found that some other people that have same computer, face the same problem. Here is some information about it: ****** info trace ****** * uname -a * Linux ucy-Aspire-5610Z 3.8.0-32-generic #47~precise1-Ubuntu SMP Wed Oct 2 16:22:28 UTC 2013 i686 i686 i386 GNU/Linux * lsb_release * Distributor ID: Ubuntu Description: Ubuntu 12.04.3 LTS Release: 12.04 Codename: precise * lspci * 05:00.0 Network controller [0280]: Broadcom Corporation BCM4311 802.11b/g WLAN [14e4:4311] (rev 01) Subsystem: AMBIT Microsystem Corp. Device [1468:0422] Kernel driver in use: b43-pci-bridge 06:01.0 Ethernet controller [0200]: Broadcom Corporation BCM4401-B0 100Base-TX [14e4:170c] (rev 02) Subsystem: Acer Incorporated [ALI] Device [1025:0090] Kernel driver in use: b44 * lsusb * Bus 001 Device 004: ID 04e8:6863 Samsung Electronics Co., Ltd Bus 001 Device 002: ID 5986:0100 Acer, Inc Orbicam Bus 002 Device 002: ID 046d:c52f Logitech, Inc. Wireless Mouse M305 Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 002 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 003 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 004 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 005 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub * PCMCIA Card Info * PRODID_1="" PRODID_2="" PRODID_3="" PRODID_4="" MANFID=0000,0000 FUNCID=255 * iwconfig * * rfkill * 0: acer-wireless: Wireless LAN Soft blocked: no Hard blocked: no * lsmod * ssb_hcd 12781 0 ssb 51554 2 ssb_hcd,b44 * nm-tool * NetworkManager Tool State: connected (global) Device: usb0 [Wired connection 2] ------------------------------------------- Type: Wired Driver: rndis_host State: connected Default: yes HW Address: Capabilities: Carrier Detect: yes Wired Properties Carrier: on IPv4 Settings: Address: 192.168.42.7 Prefix: 24 (255.255.255.0) Gateway: 192.168.42.129 DNS: 192.168.42.129 IPv6 Settings: Address: ::a05d:a1ff:fea4:1738 Prefix: 64 Gateway: fe80::504d:76ff:fe86:db04 Address: fe80::a05d:a1ff:fea4:1738 Prefix: 64 Gateway: fe80::504d:76ff:fe86:db04 DNS: fe80::504d:76ff:fe86:db04 Device: eth2 ----------------------------------------------------------------- Type: Wired Driver: b44 State: unavailable Default: no HW Address: Capabilities: Carrier Detect: yes Wired Properties Carrier: off * NetworkManager.state * [main] NetworkingEnabled=true WirelessEnabled=true WWANEnabled=true WimaxEnabled=true * NetworkManager.conf * [main] plugins=ifupdown,keyfile dns=dnsmasq [ifupdown] managed=false * interfaces * auto lo iface lo inet loopback * iwlist * * resolv.conf * nameserver 127.0.0.1 * blacklist * [/etc/modprobe.d/blacklist-ath_pci.conf] blacklist ath_pci [/etc/modprobe.d/blacklist-bcm43.conf] blacklist b43 blacklist b43legacy blacklist ssb blacklist bcm43xx blacklist brcm80211 blacklist brcmfmac blacklist brcmsmac blacklist bcma [/etc/modprobe.d/blacklist.conf] blacklist evbug blacklist usbmouse blacklist usbkbd blacklist eepro100 blacklist de4x5 blacklist eth1394 blacklist snd_intel8x0m blacklist snd_aw2 blacklist i2c_i801 blacklist prism54 blacklist bcm43xx blacklist garmin_gps blacklist asus_acpi blacklist snd_pcsp blacklist pcspkr blacklist amd76x_edac * modinfo * filename: /lib/modules/3.8.0-32-generic/kernel/drivers/usb/host/ssb-hcd.ko license: GPL description: Common USB driver for SSB Bus author: Hauke Mehrtens srcversion: E127A51EDC8F44D2C2A8F15 alias: ssb:v4243id0819rev* alias: ssb:v4243id0817rev* alias: ssb:v4243id0808rev* depends: ssb intree: Y vermagic: 3.8.0-32-generic SMP mod_unload modversions 686 filename: /lib/modules/3.8.0-32-generic/kernel/drivers/ssb/ssb.ko license: GPL description: Sonics Silicon Backplane driver srcversion: 14621F6EC014F731244437C alias: pci:v000014E4d00004350sv*sd*bc*sc*i* alias: pci:v000014E4d0000432Csv*sd*bc*sc*i* alias: pci:v000014E4d0000432Bsv*sd*bc*sc*i* alias: pci:v000014E4d00004329sv*sd*bc*sc*i* alias: pci:v000014E4d00004328sv*sd*bc*sc*i* alias: pci:v000014E4d00004325sv*sd*bc*sc*i* alias: pci:v000014E4d00004324sv*sd*bc*sc*i* alias: pci:v000014E4d0000A8D6sv*sd*bc*sc*i* alias: pci:v000014E4d00004322sv*sd*bc*sc*i* alias: pci:v000014E4d00004321sv*sd*bc*sc*i* alias: pci:v000014E4d00004320sv*sd*bc*sc*i* alias: pci:v000014E4d00004319sv*sd*bc*sc*i* alias: pci:v000014A4d00004318sv*sd*bc*sc*i* alias: pci:v000014E4d00004318sv*sd*bc*sc*i* alias: pci:v000014E4d00004315sv*sd*bc*sc*i* alias: pci:v000014E4d00004312sv*sd*bc*sc*i* alias: pci:v000014E4d00004311sv*sd*bc*sc*i* alias: pci:v000014E4d00004307sv*sd*bc*sc*i* alias: pci:v000014E4d00004306sv*sd*bc*sc*i* alias: pci:v000014E4d00004301sv*sd*bc*sc*i* depends: intree: Y vermagic: 3.8.0-32-generic SMP mod_unload modversions 686 * udev rules * PCI device 0x14e4:/sys/devices/pci0000:00/0000:00:1e.0/0000:06:01.0/ssb1:0 (b44) SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="", ATTR{dev_id}=="0x0", ATTR{type}=="1", KERNEL=="eth*", NAME="eth0" PCI device 0x14e4:/sys/devices/pci0000:00/0000:00:1e.0/0000:06:01.0/ssb2:0 (b44) SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="", ATTR{dev_id}=="0x0", ATTR{type}=="1", KERNEL=="eth*", NAME="eth1" PCI device 0x14e4:/sys/devices/pci0000:00/0000:00:1e.0/0000:06:01.0/ssb3:0 (b44) SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="", ATTR{dev_id}=="0x0", ATTR{type}=="1", KERNEL=="eth*", NAME="eth2" * dmesg * [ 2.385241] ssb: Found chip with id 0x4311, rev 0x01 and package 0x00 [ 2.385256] ssb: Core 0 found: ChipCommon (cc 0x800, rev 0x11, vendor 0x4243) [ 2.385266] ssb: Core 1 found: IEEE 802.11 (cc 0x812, rev 0x0A, vendor 0x4243) [ 2.385276] ssb: Core 2 found: USB 1.1 Host (cc 0x817, rev 0x03, vendor 0x4243) [ 2.385286] ssb: Core 3 found: PCI-E (cc 0x820, rev 0x01, vendor 0x4243) [ 2.448147] ssb: Sonics Silicon Backplane found on PCI device 0000:05:00.0 [ 2.468112] ssb: Found chip with id 0x4401, rev 0x02 and package 0x00 [ 2.468124] ssb: Core 0 found: Fast Ethernet (cc 0x806, rev 0x07, vendor 0x4243) [ 2.468132] ssb: Core 1 found: V90 (cc 0x807, rev 0x03, vendor 0x4243) [ 2.468140] ssb: Core 2 found: PCI (cc 0x804, rev 0x0A, vendor 0x4243) [ 2.508230] ssb: Sonics Silicon Backplane found on PCI device 0000:06:01.0 [ 2.528620] b44 ssb1:0 eth0: Broadcom 44xx/47xx 10/100 PCI ethernet driver ******** done ******** Thank you already for your help.

    Read the article

  • Secure Delete PCI-DSS Windows Environment

    - by Brennan Mann
    Hello, I have been reviewing a number of applications for securing deleting files. I understand the concepts of overwriting the file several times with zeros and random characters; however, I don't understand the concept of renaming the file up to thirty times before actually deleting the file. Any feedback would greatly be appreciated. I am currently working on a PCI DSS project. URL - SDELETE by Sysinternals http://technet.microsoft.com/en-us/sysinternals/bb897443.aspx Thanks, Brennan

    Read the article

  • Mcafee PCI Compliance failing on Session ID cookie?

    - by frio80
    Hello there. I am attempting to obtain PCI compliance for my site but the Mcafee security scan has thrown a: Potential Sensitive Persistent Cookie Sent Over a Non-Encrypted (SSL) Channel Drupal (default behavior) sets a session cookie when you simply arrive at the site. This is causing the problem. Clearly, the entire site shouldn't be under SSL; plenty of other sites set session cookies like this. What gives?

    Read the article

  • PCI scan failure for SSL Certificate with Wrong Hostname?

    - by Rob Mangiafico
    A client had a PCI scan completed by SecurityMetrics, and it now says they failed due to the SSL certificate for the SMTP port 25 (and POP3s/IMAPS) not matching the domain scanned. Specifically: Description: SSL Certificate with Wrong Hostname Synoposis: The SSL certificate for this service is for a different host. Impact: The commonName (CN) of the SSL certificate presented on this service is for a different machine. The mail server uses sendmail (patched) and provides email service for a number of domains. The server itself has a valid SSL certificate, but it does not match each domain (as we add/remove domains all the time as clients move around). Seems SecurityMerics is the only ASV that marks this as failing PCI. Trustwave, McAfee, etc... do not see this as failing PCI. Is this issue truly a PCI failure? Or is it just SecuritMetrics being wrong?

    Read the article

  • Can I flash a PCI-E device's Firmware in a VM if the VM has exclusive IOMMU access?

    - by RibaldEddie
    I have a PCI-E Dell Perc 6/i RAID card that I'd like to flash with the latest firmware. Apparently I need either a Redhat / Centos OS or Windows in order to flash the firmware, but I have a VMWare 5.0.1 ESX hypervisor installed on the box and a CentOS guest OS. My motherboard support IOMMU and I have successfully used VMWare's PCI Passthrough feature to give VMs exclusive access to a PCI-E device. Is it safe to flash the firmware of a PCI-E device if that device is passed through to a single VM using the passthrough feature of VMware? Or should I boot one of the supported OSes directly on the bare metal?

    Read the article

  • Does the use of a POS terminal mean I need PCI DSS compliance?

    - by Nic
    I've read a lot about PCI DSS and its requirements, but I'm unclear on what exactly determines whether an organization needs to worry about PCI DSS compliance. We accept payments using a basic HiSpeed 6200 POS terminal which is connected to the internet through our office LAN. We aren't using VLAN's. The terminal isn't integrated with any payment processing applications, it just prints out paper receipts. Do I need to worry about PCI DSS compliance?

    Read the article

  • Patching and PCI Compliance

    - by Joel Weise
    One of my friends and master of the security universe, Darren Moffat, pointed me to Dan Anderson's blog the other day.  Dan went to Toorcon which is a security conference where he went to a talk on security patching titled, "Stop Patching, for Stronger PCI Compliance".  I realize that often times speakers will use a headline grabbing title to create interest in their talk and this one certainly got my attention.  I did not go to the conference and did not see the presentation, so I can only go by what is in the Toorcon agenda summary and on Dan's blog, but the general statement to stop patching for stronger PCI compliance seems a bit misleading to me.  Clearly patching is important to all systems management and should be a part of any organization's security hygiene.  Further, PCI does require the patching of systems to maintain compliance.  So it's important to mention that organizations should not simply stop patching their systems; and I want to believe that was not the speakers intent. So let's look at PCI requirement 6: "Unscrupulous individuals use security vulnerabilities to gain privileged access to systems. Many of these vulnerabilities are fixed by vendor- provided security patches, which must be installed by the entities that manage the systems. All critical systems must have the most recently released, appropriate software patches to protect against exploitation and compromise of cardholder data by malicious individuals and malicious software." Notice the word "appropriate" in the requirement.  This is stated to give organizations some latitude and apply patches that make sense in their environment and that target the vulnerabilities in question.  Haven't we all seen a vulnerability scanner throw a false positive and flag some module and point to a recommended patch, only to realize that the module doesn't exist on our system?  Applying such a patch would obviously not be appropriate.  This does not mean an organization can ignore the fact they need to apply security patches.  It's pretty clear they must.  Of course, organizations have other options in terms of compliance when it comes to patching.  For example, they could remove a system from scope and make sure that system does not process or contain cardholder data.  [This may or may not be a significant undertaking.  I just wanted to point out that there are always options available.] PCI DSS requirement 6.1 also includes the following note: "Note: An organization may consider applying a risk-based approach to prioritize their patch installations. For example, by prioritizing critical infrastructure (for example, public-facing devices and systems, databases) higher than less-critical internal devices, to ensure high-priority systems and devices are addressed within one month, and addressing less critical devices and systems within three months." Notice there is no mention to stop patching one's systems.  And the note also states organization may apply a risk based approach. [A smart approach but also not mandated].  Such a risk based approach is not intended to remove the requirement to patch one's systems.  It is meant, as stated, to allow one to prioritize their patch installations.   So what does this mean to an organization that must comply with PCI DSS and maintain some sanity around their patch management and overall operational readiness?  I for one like to think that most organizations take a common sense and balanced approach to their business and security posture.  If patching is becoming an unbearable task, review why that is the case and possibly look for means to improve operational efficiencies; but also recognize that security is important to maintaining the availability and integrity of one's systems.  Likewise, whether we like it or not, the cyber-world we live in is getting more complex and threatening - and I dont think it's going to get better any time soon.

    Read the article

  • IRQ problem with 2.6.32/2.6.39 kernel on Debian Squeeze x86_64

    - by MasterM
    I recently assembled a new computer so that all hardware is pretty new. Since then I've been experiencing some problem with IRQs when running Debian 6.0. On random occasions, usually after an hour or so of running I hear a beep and this shows up in dmesg: [ 3537.762795] irq 16: nobody cared (try booting with the "irqpoll" option) [ 3537.762797] Pid: 0, comm: swapper Tainted: P W O 2.6.39-2-amd64 #1 [ 3537.762798] Call Trace: [ 3537.762799] <IRQ> [<ffffffff810924d4>] ? __report_bad_irq+0x3a/0xa2 [ 3537.762803] [<ffffffff810926a4>] ? note_interrupt+0x168/0x1da [ 3537.762805] [<ffffffff81090dd4>] ? handle_irq_event_percpu+0x171/0x18f [ 3537.762807] [<ffffffff8100e0e2>] ? read_tsc+0x5/0x16 [ 3537.762809] [<ffffffff8106b8a2>] ? update_ts_time_stats+0x32/0x6b [ 3537.762810] [<ffffffff81090e26>] ? handle_irq_event+0x34/0x52 [ 3537.762812] [<ffffffff81063fb7>] ? sched_clock_idle_wakeup_event+0x12/0x1c [ 3537.762813] [<ffffffff81092df2>] ? handle_fasteoi_irq+0x82/0xa4 [ 3537.762815] [<ffffffff8100aadb>] ? handle_irq+0x1a/0x23 [ 3537.762816] [<ffffffff8100a384>] ? do_IRQ+0x45/0xaa [ 3537.762818] [<ffffffff81332c93>] ? common_interrupt+0x13/0x13 [ 3537.762818] <EOI> [<ffffffff81332c8e>] ? common_interrupt+0xe/0x13 [ 3537.762821] [<ffffffff81026800>] ? native_safe_halt+0x2/0x3 [ 3537.762829] [<ffffffffa016ed58>] ? acpi_idle_do_entry+0x39/0x62 [processor] [ 3537.762831] [<ffffffffa016edde>] ? acpi_idle_enter_c1+0x5d/0xad [processor] [ 3537.762834] [<ffffffff81261033>] ? cpuidle_idle_call+0x11f/0x1cc [ 3537.762835] [<ffffffff81008dd2>] ? cpu_idle+0xab/0xe1 [ 3537.762837] [<ffffffff8169fc60>] ? start_kernel+0x3e0/0x3eb [ 3537.762838] [<ffffffff8169f3c8>] ? x86_64_start_kernel+0x102/0x10f [ 3537.762839] handlers: [ 3537.762840] [<ffffffffa0358d5a>] (rtl8169_interrupt+0x0/0x2d7 [r8169]) [ 3537.762842] [<ffffffffa08ff2ca>] (nv_kern_isr+0x0/0x54 [nvidia]) [ 3537.762902] Disabling IRQ #16 After that Xorg either hogs on CPU or is unstable (up to hanging the system completely). When I restart Xorg everything is fine again and the problem doesn't occur until next reboot. I tried to upgrade the kernel from stock 2.6.32 to 2.6.39 from unstable repository but that didn't help. Booting with irqpoll option only seems to prolong the initial time period after which the problem occurs. I'm using latest NVIDIA drivers and Realtek firmware from firmware-realtek package. I have two GTX 560Ti that run in SLI. Disabling SLI or taking out one card completely doesn't solve the problem either. Output of uname -a is: Linux whitestar 2.6.39-2-amd64 #1 SMP Wed Jun 8 11:01:04 UTC 2011 x86_64 GNU/Linux Output of lspci is: 00:00.0 Host bridge: Intel Corporation Sandy Bridge DRAM Controller (rev 09) 00:01.0 PCI bridge: Intel Corporation Sandy Bridge PCI Express Root Port (rev 09) 00:01.1 PCI bridge: Intel Corporation Sandy Bridge PCI Express Root Port (rev 09) 00:16.0 Communication controller: Intel Corporation Cougar Point HECI Controller #1 (rev 04) 00:19.0 Ethernet controller: Intel Corporation 82579V Gigabit Network Connection (rev 05) 00:1a.0 USB Controller: Intel Corporation Cougar Point USB Enhanced Host Controller #2 (rev 05) 00:1b.0 Audio device: Intel Corporation Cougar Point High Definition Audio Controller (rev 05) 00:1c.0 PCI bridge: Intel Corporation Cougar Point PCI Express Root Port 1 (rev b5) 00:1c.1 PCI bridge: Intel Corporation Cougar Point PCI Express Root Port 2 (rev b5) 00:1c.2 PCI bridge: Intel Corporation Cougar Point PCI Express Root Port 3 (rev b5) 00:1c.4 PCI bridge: Intel Corporation Cougar Point PCI Express Root Port 5 (rev b5) 00:1c.6 PCI bridge: Intel Corporation 82801 PCI Bridge (rev b5) 00:1d.0 USB Controller: Intel Corporation Cougar Point USB Enhanced Host Controller #1 (rev 05) 00:1f.0 ISA bridge: Intel Corporation Cougar Point LPC Controller (rev 05) 00:1f.2 SATA controller: Intel Corporation Cougar Point 6 port SATA AHCI Controller (rev 05) 00:1f.3 SMBus: Intel Corporation Cougar Point SMBus Controller (rev 05) 01:00.0 VGA compatible controller: nVidia Corporation Device 1200 (rev a1) 01:00.1 Audio device: nVidia Corporation Device 0e0c (rev a1) 02:00.0 VGA compatible controller: nVidia Corporation Device 1200 (rev a1) 02:00.1 Audio device: nVidia Corporation Device 0e0c (rev a1) 04:00.0 USB Controller: NEC Corporation uPD720200 USB 3.0 Host Controller (rev 04) 06:00.0 USB Controller: NEC Corporation uPD720200 USB 3.0 Host Controller (rev 04) 07:00.0 PCI bridge: Device 1b21:1080 (rev 01) 08:02.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL-8110SC/8169SC Gigabit Ethernet (rev 10) 08:03.0 FireWire (IEEE 1394): VIA Technologies, Inc. VT6306/7/8 [Fire II(M)] IEEE 1394 OHCI Controller (rev c0) Contents of /proc/interrupts: CPU0 CPU1 CPU2 CPU3 CPU4 CPU5 CPU6 CPU7 0: 77 0 0 0 0 0 0 0 IO-APIC-edge timer 1: 2 0 0 0 0 0 0 0 IO-APIC-edge i8042 8: 1 0 0 0 0 0 0 0 IO-APIC-edge rtc0 9: 0 0 0 0 0 0 0 0 IO-APIC-fasteoi acpi 12: 4 0 0 0 0 0 0 0 IO-APIC-edge i8042 16: 699083 0 0 0 0 0 0 0 IO-APIC-fasteoi nvidia, eth0 17: 87810 0 0 0 0 0 0 0 IO-APIC-fasteoi firewire_ohci, hda_intel, nvidia 18: 242 0 0 0 0 0 0 0 IO-APIC-fasteoi hda_intel 23: 85925 0 0 0 0 0 0 0 IO-APIC-fasteoi ehci_hcd:usb5, ehci_hcd:usb6 40: 0 0 0 0 0 0 0 0 PCI-MSI-edge PCIe PME 41: 0 0 0 0 0 0 0 0 PCI-MSI-edge PCIe PME 42: 0 0 0 0 0 0 0 0 PCI-MSI-edge PCIe PME 43: 0 0 0 0 0 0 0 0 PCI-MSI-edge PCIe PME 44: 0 0 0 0 0 0 0 0 PCI-MSI-edge PCIe PME 45: 0 0 0 0 0 0 0 0 PCI-MSI-edge PCIe PME 46: 79853 0 0 0 0 0 0 0 PCI-MSI-edge ahci 48: 1 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 49: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 50: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 51: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 52: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 53: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 54: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 55: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 56: 1 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 57: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 58: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 59: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 60: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 61: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 62: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 63: 0 0 0 0 0 0 0 0 PCI-MSI-edge xhci_hcd 64: 173506 0 0 0 0 0 0 0 PCI-MSI-edge hda_intel NMI: 482 89 25 13 277 24 11 10 Non-maskable interrupts LOC: 783857 194752 114133 70577 372438 179065 117179 162016 Local timer interrupts SPU: 0 0 0 0 0 0 0 0 Spurious interrupts PMI: 482 89 25 13 277 24 11 10 Performance monitoring interrupts IWI: 0 0 0 0 0 0 0 0 IRQ work interrupts RES: 131917 46750 7432 3291 150003 9576 3435 3067 Rescheduling interrupts CAL: 2759 6563 7150 6997 5387 7140 7269 6678 Function call interrupts TLB: 4396 2038 1336 492 5434 1896 1121 606 TLB shootdowns TRM: 0 0 0 0 0 0 0 0 Thermal event interrupts THR: 0 0 0 0 0 0 0 0 Threshold APIC interrupts MCE: 0 0 0 0 0 0 0 0 Machine check exceptions MCP: 37 37 37 37 37 37 37 37 Machine check polls ERR: 0 MIS: 0 Last but not least, right after boot-up those lines are usually present in dmesg: [ 18.367094] hda-intel: IRQ timing workaround is activated for card #1. Suggest a bigger bdl_pos_adj. [ 18.458859] hda-intel: IRQ timing workaround is activated for card #2. Suggest a bigger bdl_pos_adj. I'm not sure if it's related or a symptom of a bigger problem so I'm posting it just in case. I don't really know what other information might be of relevance here. Don't hesitate to ask for more in the comments.

    Read the article

  • Missing driver ASUS PCE-N53 11n N600 PCI-E Adapter

    - by oyse
    I have problems with getting an Asus PCE-N53 11n N600 PCI-E Adapter card to work on my desktop computer. As far as I can tell no drivers are installed for the card. I know I can manually download the drivers directly from Asus, but I would rather not go that route. If there are anyone that knows about any packages or other things I can do to make this work would be much appreciated. Some systems details: $ lsb_release -a No LSB modules are available. Distributor ID: Ubuntu Description: Ubuntu 12.04.1 LTS Release: 12.04 Codename: precise $ sudo lshw -C network *-network description: Ethernet interface product: RTL8111/8168B PCI Express Gigabit Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:03:00.0 logical name: eth0 version: 06 serial: d4:3d:7e:03:b9:1d size: 100Mbit/s capacity: 1Gbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix vpd bus_master cap_list ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8169 driverversion=2.3LK-NAPI duplex=full firmware=rtl8168e-3_0.0.4 03/27/12 ip=192.168.0.173 latency=0 link=yes multicast=yes port=MII speed=100Mbit/s resources: irq:43 ioport:d000(size=256) memory:f2104000-f2104fff memory:f2100000-f2103fff *-network UNCLAIMED description: Network controller product: Ralink corp. vendor: Ralink corp. physical id: 0 bus info: pci@0000:04:00.0 version: 00 width: 32 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list configuration: latency=0 resources: memory:f7100000-f710ffff $ lsmod Module Size Used by nvidia 12319264 51 vesafb 13844 1 snd_hda_codec_hdmi 32474 1 joydev 17693 0 bnep 18281 2 rfcomm 47604 0 bluetooth 180104 10 bnep,rfcomm snd_hda_codec_realtek 224173 1 snd_seq_midi 13324 0 ppdev 17113 0 snd_rawmidi 30748 1 snd_seq_midi usbhid 47199 0 hid 99559 1 usbhid nouveau 774641 0 parport_pc 32866 1 snd_hda_intel 33773 5 ttm 76949 1 nouveau snd_hda_codec 127706 3 snd_hda_codec_hdmi,snd_hda_codec_realtek,snd_hda_intel drm_kms_helper 46978 1 nouveau drm 242038 3 nouveau,ttm,drm_kms_helper snd_seq_midi_event 14899 1 snd_seq_midi snd_hwdep 13668 1 snd_hda_codec snd_seq 61896 2 snd_seq_midi,snd_seq_midi_event i2c_algo_bit 13423 1 nouveau mxm_wmi 12979 1 nouveau wmi 19256 1 mxm_wmi mac_hid 13253 0 snd_pcm 97188 3 snd_hda_codec_hdmi,snd_hda_intel,snd_hda_codec psmouse 97362 0 video 19596 1 nouveau snd_timer 29990 2 snd_seq,snd_pcm snd_seq_device 14540 3 snd_seq_midi,snd_rawmidi,snd_seq snd 78855 20 snd_hda_codec_hdmi,snd_hda_codec_realtek,snd_rawmidi,snd_hda_intel,snd_hda_codec,snd_hwdep,snd_seq,snd_pcm,snd_timer,snd_seq_device serio_raw 13211 0 soundcore 15091 1 snd snd_page_alloc 18529 2 snd_hda_intel,snd_pcm mei 41616 0 lp 17799 0 parport 46562 3 ppdev,parport_pc,lp r8169 62099 0

    Read the article

  • disable specific PCI device at boot

    - by Rhymoid
    I've just reinstalled Debian on my Sony VAIO laptop, and my dmesg and virtual consoles all get spammed with the same messages over and over again. [ 59.662381] hub 1-1:1.0: unable to enumerate USB device on port 2 [ 59.901732] usb 1-1.2: new high-speed USB device number 91 using ehci_hcd [ 59.917940] hub 1-1:1.0: unable to enumerate USB device on port 2 [ 60.157256] usb 1-1.2: new high-speed USB device number 92 using ehci_hcd I believe these messages are coming from an internally connected USB device, most likely the webcam (since that's the only thing that doesn't work). The only way I can seem to have it shut up (without killing my actually useful USB ports) is to disable one of the USB host controllers: # echo "0000:00:1a.0" > /sys/bus/pci/drivers/ehci_hcd/unbind This also takes down my Bluetooth interface, but I'm fine with that. I would like this setting to persist, so that I can painlessly use my virtual console again in case I need it. I want my operating system (Debian amd64) to never wake it up, but I don't know how to do this. I've tried to blacklist the module alias for the PCI device, but it seems to be ignored: $ cat /sys/bus/pci/devices/0000\:00\:1a.0/modalias pci:v00008086d00003B3Csv0000104Dsd00009071bc0Csc03i20 $ cat /etc/modprobe.d/blacklist blacklist pci:v00008086d00003B3Csv0000104Dsd00009071bc0Csc03i20 How do I ensure that this specific PCI device is never automatically activated, without disabling its driver altogether? -edit- The module was renamed recently, now the following works from userland: echo "0000:00:1a.0" > /sys/bus/pci/drivers/ehci-pci/unbind Still, I'm looking for a way to stop the kernel from binding that device in the first place.

    Read the article

  • Setting Boot and Mirror Disks correctly at the Solaris OBP

    - by Shaun Dewberry
    I am recovering a domain that was lost due to power outage on an Sun Fire E25K server. I know how to set the appropriate parameters at the openboot prompt using nvalias/devalias, boot etc. However, I do not understand how one gets from the output of show-disks {1a0} ok show-disks a) /pci@1dd,600000/SUNW,qlc@1/fp@0,0/disk b) /pci@1dd,700000/SUNW,qlc@1/fp@0,0/disk c) /pci@1dc,700000/pci@1/pci@1/scsi@2,1/disk d) /pci@1dc,700000/pci@1/pci@1/scsi@2/disk e) /pci@1bd,600000/SUNW,qlc@1/fp@0,0/disk f) /pci@1bd,700000/SUNW,qlc@1/fp@0,0/disk g) /pci@1bc,700000/pci@1/pci@1/scsi@2,1/disk h) /pci@1bc,700000/pci@1/pci@1/scsi@2/disk q) NO SELECTION Enter Selection, q to quit: to the correct full disk path. I know it is basically one of the pci/scsi paths listed above, but in all instruction or examples a string of additional characters is appended to the path to specify Targets and Units but the explanation of the path construction is never given. Could someone please explain how to construct this disk path correctly?

    Read the article

  • Why did Ubuntu suddenly get so slow?

    - by user101383
    12.10 has been slowing down mysteriously. Normally, in past versions, I can log in, open Firefox, and it will pop up within seconds. 12.10 is like that upon install too, though once I install my old apps, it gets very slow by Ubuntu standards. After login the hard drive will just make noise for a while before the OS will do anything. Hardware: enter description: Desktop Computer product: XPS 8300 () vendor: Dell Inc. serial: B6G2WR1 width: 64 bits capabilities: smbios-2.6 dmi-2.6 vsyscall32 configuration: boot=normal chassis=desktop uuid=44454C4C-3600-1047-8032-C2C04F575231 core description: Motherboard product: 0Y2MRG vendor: Dell Inc. physical id: 0 version: A00 serial: ..CN7360419G04VQ. slot: To Be Filled By O.E.M. *cpu description: CPU product: Intel(R) Core(TM) i7-2600 CPU @ 3.40GHz vendor: Intel Corp. physical id: 4 bus info: cpu@0 version: Intel(R) Core(TM) i7-2600 CPU @ 3.40GHz serial: To Be Filled By O.E.M. slot: CPU 1 size: 1600MHz capacity: 1600MHz width: 64 bits clock: 100MHz capabilities: x86-64 fpu fpu_exception wp vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm pbe syscall nx rdtscp constant_tsc arch_perfmon pebs bts rep_good nopl xtopology nonstop_tsc aperfmperf pni pclmulqdq dtes64 monitor ds_cpl vmx smx est tm2 ssse3 cx16 xtpr pdcm pcid sse4_1 sse4_2 x2apic popcnt tsc_deadline_timer aes xsave avx lahf_lm ida arat epb xsaveopt pln pts dtherm tpr_shadow vnmi flexpriority ept vpid cpufreq configuration: cores=4 enabledcores=1 threads=2 *-cache:0 description: L1 cache physical id: 5 slot: L1-Cache size: 256KiB capacity: 256KiB capabilities: internal write-through unified *-cache:1 description: L2 cache physical id: 6 slot: L2-Cache size: 1MiB capacity: 1MiB capabilities: internal write-through unified *-cache:2 DISABLED description: L3 cache physical id: 7 slot: L3-Cache size: 8MiB capacity: 8MiB capabilities: internal write-back unified *-memory description: System Memory physical id: 20 slot: System board or motherboard size: 8GiB *-bank:0 description: SODIMM DDR3 Synchronous 1333 MHz (0.8 ns) product: NT2GC64B88B0NF-CG vendor: Nanya physical id: 0 serial: 7228183 slot: DIMM3 size: 2GiB width: 64 bits clock: 1333MHz (0.8ns) *-bank:1 description: SODIMM DDR3 Synchronous 1333 MHz (0.8 ns) product: NT2GC64B88B0NF-CG vendor: Nanya physical id: 1 serial: 1E28183 slot: DIMM1 size: 2GiB width: 64 bits clock: 1333MHz (0.8ns) *-bank:2 description: SODIMM DDR3 Synchronous 1333 MHz (0.8 ns) product: NT2GC64B88B0NF-CG vendor: Nanya physical id: 2 serial: 9E28183 slot: DIMM4 size: 2GiB width: 64 bits clock: 1333MHz (0.8ns) *-bank:3 description: SODIMM DDR3 Synchronous 1333 MHz (0.8 ns) product: NT2GC64B88B0NF-CG vendor: Nanya physical id: 3 serial: 5527183 slot: DIMM2 size: 2GiB width: 64 bits clock: 1333MHz (0.8ns) *-firmware description: BIOS vendor: Dell Inc. physical id: 0 version: A05 date: 09/21/2011 size: 64KiB capacity: 4032KiB capabilities: mca pci upgrade shadowing escd cdboot bootselect socketedrom edd int13floppy1200 int13floppy720 int13floppy2880 int5printscreen int9keyboard int14serial int17printer int10video acpi usb zipboot biosbootspecification *-pci description: Host bridge product: 2nd Generation Core Processor Family DRAM Controller vendor: Intel Corporation physical id: 100 bus info: pci@0000:00:00.0 version: 09 width: 32 bits clock: 33MHz *-pci:0 description: PCI bridge product: Xeon E3-1200/2nd Generation Core Processor Family PCI Express Root Port vendor: Intel Corporation physical id: 1 bus info: pci@0000:00:01.0 version: 09 width: 32 bits clock: 33MHz capabilities: pci pm msi pciexpress normal_decode bus_master cap_list configuration: driver=pcieport resources: irq:40 ioport:e000(size=4096) memory:fe600000-fe6fffff ioport:d0000000(size=268435456) *-display description: VGA compatible controller product: Juniper [Radeon HD 5700 Series] vendor: Advanced Micro Devices [AMD] nee ATI physical id: 0 bus info: pci@0000:01:00.0 version: 00 width: 64 bits clock: 33MHz capabilities: pm pciexpress msi vga_controller bus_master cap_list rom configuration: driver=radeon latency=0 resources: irq:44 memory:d0000000-dfffffff memory:fe620000-fe63ffff ioport:e000(size=256) memory:fe600000-fe61ffff *-multimedia description: Audio device product: Juniper HDMI Audio [Radeon HD 5700 Series] vendor: Advanced Micro Devices [AMD] nee ATI physical id: 0.1 bus info: pci@0000:01:00.1 version: 00 width: 64 bits clock: 33MHz capabilities: pm pciexpress msi bus_master cap_list configuration: driver=snd_hda_intel latency=0 resources: irq:48 memory:fe640000-fe643fff *-communication description: Communication controller product: 6 Series/C200 Series Chipset Family MEI Controller #1 vendor: Intel Corporation physical id: 16 bus info: pci@0000:00:16.0 version: 04 width: 64 bits clock: 33MHz capabilities: pm msi bus_master cap_list configuration: driver=mei latency=0 resources: irq:45 memory:fe708000-fe70800f *-usb:0 description: USB controller product: 6 Series/C200 Series Chipset Family USB Enhanced Host Controller #2 vendor: Intel Corporation physical id: 1a bus info: pci@0000:00:1a.0 version: 05 width: 32 bits clock: 33MHz capabilities: pm debug ehci bus_master cap_list configuration: driver=ehci_hcd latency=0 resources: irq:16 memory:fe707000-fe7073ff *-multimedia description: Audio device product: 6 Series/C200 Series Chipset Family High Definition Audio Controller vendor: Intel Corporation physical id: 1b bus info: pci@0000:00:1b.0 version: 05 width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list configuration: driver=snd_hda_intel latency=0 resources: irq:46 memory:fe700000-fe703fff *-pci:1 description: PCI bridge product: 6 Series/C200 Series Chipset Family PCI Express Root Port 1 vendor: Intel Corporation physical id: 1c bus info: pci@0000:00:1c.0 version: b5 width: 32 bits clock: 33MHz capabilities: pci pciexpress msi pm normal_decode bus_master cap_list configuration: driver=pcieport resources: irq:41 memory:fe500000-fe5fffff *-network description: Network controller product: BCM4313 802.11b/g/n Wireless LAN Controller vendor: Broadcom Corporation physical id: 0 bus info: pci@0000:02:00.0 version: 01 width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list configuration: driver=bcma-pci-bridge latency=0 resources: irq:16 memory:fe500000-fe503fff *-pci:2 description: PCI bridge product: 6 Series/C200 Series Chipset Family PCI Express Root Port 4 vendor: Intel Corporation physical id: 1c.3 bus info: pci@0000:00:1c.3 version: b5 width: 32 bits clock: 33MHz capabilities: pci pciexpress msi pm normal_decode bus_master cap_list configuration: driver=pcieport resources: irq:42 memory:fe400000-fe4fffff *-network description: Ethernet interface product: NetLink BCM57788 Gigabit Ethernet PCIe vendor: Broadcom Corporation physical id: 0 bus info: pci@0000:03:00.0 logical name: eth0 version: 01 serial: 18:03:73:e1:a7:71 size: 100Mbit/s capacity: 1Gbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=tg3 driverversion=3.123 duplex=full firmware=sb ip=192.168.1.3 latency=0 link=yes multicast=yes port=MII speed=100Mbit/s resources: irq:47 memory:fe400000-fe40ffff *-usb:1 description: USB controller product: 6 Series/C200 Series Chipset Family USB Enhanced Host Controller #1 vendor: Intel Corporation physical id: 1d bus info: pci@0000:00:1d.0 version: 05 width: 32 bits clock: 33MHz capabilities: pm debug ehci bus_master cap_list configuration: driver=ehci_hcd latency=0 resources: irq:23 memory:fe706000-fe7063ff *-isa description: ISA bridge product: H67 Express Chipset Family LPC Controller vendor: Intel Corporation physical id: 1f bus info: pci@0000:00:1f.0 version: 05 width: 32 bits clock: 33MHz capabilities: isa bus_master cap_list configuration: latency=0 *-storage description: SATA controller product: 6 Series/C200 Series Chipset Family SATA AHCI Controller vendor: Intel Corporation physical id: 1f.2 bus info: pci@0000:00:1f.2 version: 05 width: 32 bits clock: 66MHz capabilities: storage msi pm ahci_1.0 bus_master cap_list configuration: driver=ahci latency=0 resources: irq:43 ioport:f070(size=8) ioport:f060(size=4) ioport:f050(size=8) ioport:f040(size=4) ioport:f020(size=32) memory:fe705000-fe7057ff *-serial UNCLAIMED description: SMBus product: 6 Series/C200 Series Chipset Family SMBus Controller vendor: Intel Corporation physical id: 1f.3 bus info: pci@0000:00:1f.3 version: 05 width: 64 bits clock: 33MHz configuration: latency=0 resources: memory:fe704000-fe7040ff ioport:f000(size=32) *-scsi:0 physical id: 1 logical name: scsi0 capabilities: emulated *-disk description: ATA Disk product: Hitachi HUA72201 vendor: Hitachi physical id: 0.0.0 bus info: scsi@0:0.0.0 logical name: /dev/sda version: JP4O serial: JPW9J0HD21BTZC size: 931GiB (1TB) capabilities: partitioned partitioned:dos configuration: ansiversion=5 sectorsize=512 signature=000641dc *-volume:0 description: EXT4 volume vendor: Linux physical id: 1 bus info: scsi@0:0.0.0,1 logical name: /dev/sda1 logical name: / version: 1.0 serial: 4e3d91b7-fd38-4f44-a9e9-ba3c39b926ec size: 585GiB capacity: 585GiB capabilities: primary journaled extended_attributes large_files huge_files dir_nlink recover extents ext4 ext2 initialized configuration: created=2012-10-21 16:26:50 filesystem=ext4 lastmountpoint=/ modified=2012-10-29 18:12:08 mount.fstype=ext4 mount.options=rw,relatime,errors=remount-ro,data=ordered mounted=2012-10-29 18:12:08 state=mounted *-volume:1 description: Extended partition physical id: 2 bus info: scsi@0:0.0.0,2 logical name: /dev/sda2 size: 7823MiB capacity: 7823MiB capabilities: primary extended partitioned partitioned:extended *-logicalvolume description: Linux swap / Solaris partition physical id: 5 logical name: /dev/sda5 capacity: 7823MiB capabilities: nofs *-volume:2 description: Windows NTFS volume physical id: 3 bus info: scsi@0:0.0.0,3 logical name: /dev/sda3 version: 3.1 serial: 84a92aae-347b-7940-a2d1-f4745b885ef2 size: 337GiB capacity: 337GiB capabilities: primary bootable ntfs initialized configuration: clustersize=4096 created=2012-10-21 18:43:39 filesystem=ntfs modified_by_chkdsk=true mounted_on_nt4=true resize_log_file=true state=dirty upgrade_on_mount=true *-scsi:1 physical id: 2 logical name: scsi1 capabilities: emulated *-cdrom description: DVD-RAM writer product: DVDRWBD DH-12E3S vendor: PLDS physical id: 0.0.0 bus info: scsi@1:0.0.0 logical name: /dev/cdrom logical name: /dev/cdrw logical name: /dev/dvd logical name: /dev/dvdrw logical name: /dev/sr0 version: MD11 capabilities: removable audio cd-r cd-rw dvd dvd-r dvd-ram configuration: ansiversion=5 status=nodisc *-scsi:2 physical id: 3 bus info: usb@2:1.8 logical name: scsi6 capabilities: emulated scsi-host configuration: driver=usb-storage *-disk:0 description: SCSI Disk physical id: 0.0.0 bus info: scsi@6:0.0.0 logical name: /dev/sdb configuration: sectorsize=512 *-disk:1 description: SCSI Disk physical id: 0.0.1 bus info: scsi@6:0.0.1 logical name: /dev/sdc configuration: sectorsize=512 *-disk:2 description: SCSI Disk physical id: 0.0.2 bus info: scsi@6:0.0.2 logical name: /dev/sdd configuration: sectorsize=512 *-disk:3 description: SCSI Disk product: MS/MS-Pro vendor: Generic- physical id: 0.0.3 bus info: scsi@6:0.0.3 logical name: /dev/sde version: 1.03 serial: 3 capabilities: removable configuration: sectorsize=512 *-medium physical id: 0 logical name: /dev/sde

    Read the article

  • authorize.net SIM PCI compliance

    - by David
    Does anyone know if authorize.net's SIM rids you of having to be PCI compliant? The payment form is hosted on authorize.net's site and they're processing the payment. I know you can do a relay response which basically puts some of the transaction details in a url that goes back to your website(to display a receipt). I'm not sure what all information gets put into the url though. I'm wondering if that makes you have to become PCI compliant?

    Read the article

  • How to interpret the contents of /proc/bus/pci/devices ?

    - by vivekian2
    The first few fields of 'cat /proc/bus/pci/devices' are understandable. Field 1 - BusDevFunc Field 2 - Vendor Id + Device Id Field 3 - Interrupt Line Field 4 - BAR 0 and the rest of the BAR registers (0 - 5) after that. After the BAR registers are printed out, what are the other fields? Specifically, what PCI configuration space registers(offsets) are printed out?

    Read the article

  • Making Agile and DevOps methodology compatible with PCI requirements

    - by kenchew
    Would like to hear from those working in a PCI compliance environment and is practicing agile development and devops methodology, how you maintain compliance with PCI requirements. Specifically, what do you do to address: separation of duties between development/test and production alignment of continuous integration / deployment and change control alignment of agile stories to requirement documentation

    Read the article

< Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >