Search Results

Search found 105 results on 5 pages for 'serialport'.

Page 4/5 | < Previous Page | 1 2 3 4 5  | Next Page >

  • Why .NET does not allow cross-thread operations?

    - by RHaguiuda
    This question is not about what is a cross-thread operation, and how to avoid it, but why internal mechanics of .NET framework does not allow a cross-thread operation. I can`t understand why a SerialPort DataReceived event cannot update a simple text box on my form and why using delegates this is possible?

    Read the article

  • Calling managed code from unmanaged win32 assembly dll - crash

    - by JustGreg
    I'm developing a serial port dll in win32 assembly (MASM32). It has its own thread checking multiple events and at a specified buffer treshold it'd notify the managed main application by calling a callback function. It just a call with no arguments/return value. At startup the main application stores the callback function's address by calling a function in the dll: pCallBackFunction dd 0 SetCallBackPointer proc pcb:DWORD mov eax, pcb mov pCallBackFunction, eax call DWORD ptr pCallBackFunction ; verify it immediately ret SetCallBackPointer endp The upper function immediately calls back the managed application callback routine for verification purposes. It is working fine. However, when I place the call instruction to other functions in the dll it crashes the application. It doesn't matter if the call is in a simple function or in the threadproc of the dll. For example: OpenPort proc pn:byte,br:dword, inputbuffersize: dword, outputbuffersize:dword, tresholdsize: dword LOCAL dcb: DCB LOCAL SerialTimeOuts: COMMTIMEOUTS call DWORD ptr pCallBackFunction xor eax, eax mov al, pn mov [com_port+3],al etc. etc. will crash at call DWORD ptr pCallBackFunction always. Since I call SetCallBackPointer first to store a valid address in pCallBackFunction, it should have a valid address. My managed app is written in C# and the relevant part is: public partial class Form1 : Form { public delegate void CallBackDelegate(); public static CallBackDelegate mydelegate; [DllImport("serialport.dll")] private static extern void SetCallBackPointer(CallBackDelegate Delegate); [DllImport("serialport.dll")] public static extern int OpenPort(byte com, uint br, uint inbufsize, uint outbufsize, uint treshsize); public Form1() { InitializeComponent(); mydelegate =new CallBackDelegate(CallbackFunction); SetCallBackPointer(mydelegate); unsafe { int sysstat; int hResult; hResult = OpenPort(Convert.ToByte('5'), 9600, 306, 4, 4); } } public static void CallbackFunction() { MessageBox.Show( "CallBack Function Called by Windows DLL"); } The VS debugger reported that the dll had tried to read/write from/to a protected memory address. But when calling SetCallBackPointer there is no such problem. What am I doing wrong here? Any tips would be great!

    Read the article

  • Why does C# thread die?

    - by JackN
    This is my 1st C# project so I may be doing something obviously improper in the code below. I am using .NET, WinForms (I think), and this is a desktop application until I get the bugs out. UpdateGui() uses Invoke((MethodInvoker)delegate to update various GUI controls based on received serial data and sends a GetStatus() command out the serial port 4 times a second. Thread Read() reads the response from serial port whenever it arrives which should be near immediate. SerialPortFixer is a SerialPort IOException Workaround in C# I found at http://zachsaw.blogspot.com/2010/07/serialport-ioexception-workaround-in-c.html. After one or both threads die I'll see something like The thread 0x1288 has exited with code 0 (0x0). in the debug code output. Why do UpdateGui() and/or Read() eventually die? public partial class UpdateStatus : Form { private readonly byte[] Command = new byte[32]; private readonly byte[] Status = new byte[32]; readonly Thread readThread; private static readonly Mutex commandMutex = new Mutex(); private static readonly Mutex statusMutex = new Mutex(); ... public UpdateStatus() { InitializeComponent(); SerialPortFixer.Execute("COM2"); if (serialPort1.IsOpen) { serialPort1.Close(); } try { serialPort1.Open(); } catch (Exception e) { labelWarning.Text = LOST_COMMUNICATIONS + e; labelStatus.Text = LOST_COMMUNICATIONS + e; labelWarning.Visible = true; } readThread = new Thread(Read); readThread.Start(); new Timer(UpdateGui, null, 0, 250); } static void ProcessStatus(byte[] status) { Status.State = (State) status[4]; Status.Speed = status[6]; // MSB Status.Speed *= 256; Status.Speed += status[5]; var Speed = Status.Speed/GEAR_RATIO; Status.Speed = (int) Speed; ... } public void Read() { while (serialPort1 != null) { try { serialPort1.Read(Status, 0, 1); if (Status[0] != StartCharacter[0]) continue; serialPort1.Read(Status, 1, 1); if (Status[1] != StartCharacter[1]) continue; serialPort1.Read(Status, 2, 1); if (Status[2] != (int)Command.GetStatus) continue; serialPort1.Read(Status, 3, 1); ... statusMutex.WaitOne(); ProcessStatus(Status); Status.update = true; statusMutex.ReleaseMutex(); } catch (Exception e) { Console.WriteLine(@"ERROR! Read() " + e); } } } public void GetStatus() { const int parameterLength = 0; // For GetStatus statusMutex.WaitOne(); Status.update = false; statusMutex.ReleaseMutex(); commandMutex.WaitOne(); if (!SendCommand(Command.GetStatus, parameterLength)) { Console.WriteLine(@"ERROR! SendCommand(GetStatus)"); } commandMutex.ReleaseMutex(); } private void UpdateGui(object x) { try { Invoke((MethodInvoker)delegate { Text = DateTime.Now.ToLongTimeString(); statusMutex.WaitOne(); if (Status.update) { if (Status.Speed > progressBarSpeed.Maximum) { Status.Speed = progressBarSpeed.Maximum; } progressBarSpeed.Value = Status.Speed; labelSpeed.Text = Status.Speed + RPM; ... } else { labelWarning.Text = LOST_COMMUNICATIONS; labelStatus.Text = LOST_COMMUNICATIONS; labelWarning.Visible = true; } statusMutex.ReleaseMutex(); GetStatus(); }); } catch (Exception e) { Console.WriteLine(@"ERROR! UpdateGui() " + e); } } }

    Read the article

  • Getting Serial Port Information and Sorting the Results in C#

    - by Jim Fell
    I have some code that loads the serial ports into a combo-box: comboBoxComPort.Items.Add("Select COM port..."); foreach (string s in SerialPort.GetPortNames()) { comboBoxComPort.Items.Add(s); } comboBoxComPort.SelectedIndex = 0; Ideally, I would like to add the port descriptions to the list and sort the items in the list that are after index 0. Does anyone have any suggestions for doing this? Any thoughts you may have would be appreciated. Thanks.

    Read the article

  • Getting Serial Port Information in C#

    - by Jim Fell
    I have some code that loads the serial ports into a combo-box: List<String> tList = new List<String>(); comboBoxComPort.Items.Clear(); foreach (string s in SerialPort.GetPortNames()) { tList.Add(s); } tList.Sort(); comboBoxComPort.Items.Add("Select COM port..."); comboBoxComPort.Items.AddRange(tList.ToArray()); comboBoxComPort.SelectedIndex = 0; I would like to add the port descriptions (similar to what are shown for the COM ports in the Device Manager) to the list and sort the items in the list that are after index 0 (solved: see above snippet). Does anyone have any suggestions for adding the port descriptions? I am using Microsoft Visual C# 2008 Express Edition (.NET 2.0). Any thoughts you may have would be appreciated. Thanks.

    Read the article

  • COM port - how to identify a device (.net/c#)

    - by argh
    Hi, I'm programming for Windows CE and I need to connect to a scanner. There is no problem - I know that it is on port COM0, but if I plug in another device earlier it gets another COM port... to get all com ports the easy way is: SerialPort.GetPortNames() But I don't know how to identify a device? Is there any standard way? I can't 'ping' it since there is one device that only sends data... it spams data all the time... and I don't know how to 'ping' a device...

    Read the article

  • c# ref keyword... Am i passing my value correctly?

    - by Pandiya Chendur
    Is this a valid value for this c# class default constructor, public class SMSCOMMS { public SMSCOMMS(ref string COMMPORT) { SMSPort = new SerialPort(); SMSPort.PortName = COMMPORT; SMSPort.BaudRate = 9600; SMSPort.Parity = Parity.None; SMSPort.DataBits = 8; SMSPort.StopBits = StopBits.One; SMSPort.Handshake = Handshake.RequestToSend; SMSPort.DtrEnable = true; SMSPort.RtsEnable = true; SMSPort.NewLine = System.Environment.NewLine; ReadThread = new Thread( new System.Threading.ThreadStart(ReadPort)); } and i am passing this value, SMSCOMMS SMSEngine = new SMSCOMMS("COM6"); but it doesn't seem to take "COM6" as a valid ref string... Any suggestion..

    Read the article

  • Getting wrong serial-port names from bluetoothdevice (c#)

    - by wurlog
    To get all avaliable Serialports from the system i use the following command. SerialPort.GetPortNames It works fine for the mainboard serial port, but with the bluetooth device i get the wrong portnames. For Example: Instead of COM7 i get sometimes COM70 or COM7ö. Its always 1 letter to much. any suggestens? PS: I am using newest Visual Studio Express in Windows 7 PPS: The dirty hack to cut the last letter didn't work because i don't know which one is the bluetooth serial port (with various bluetoothstick or devices it changes the number of the comport) and after trying various sticks i reached COM10, ergo COM100 or COM10f

    Read the article

  • RS 232 Communication in ASP.NET 3.5?

    - by Pandiya Chendur
    using ASP.NET 3.5 WebForm using C# 3.0, is it possible to setup a RS 232 communication with a device? I need the WebForm to be able to read and write data to the serial port. I would appreciate if there are some good examples, thanks. I understand that under Components, there is a SerialPort .NET Component, but it seems to me that it can only be used in a Windows application (WinForm). Or the only solution is to rely on the ActiveComport Serial Port Toolkit, as from http://www.activexperts.com/activcomport/howto/aspnetc/ ?

    Read the article

  • wpf app invisible remotely (via radmin)

    - by SteveCav
    hi gang, I've built a little WPF utility that watches a serialport and visualises monitoring information with WPF. It works fine, but a colleague just tried using it from another machine via radmin and my app is completely invisible! if you're at the machine you see it, if you view it via radmin you see the same screen but no app. Instead you see the app behind it (in this case windows explorer), but can't click on anything in the space where my app is. Has anyone else come across this before??

    Read the article

  • Why am I getting a Java NoSuchPortException when the port exists?

    - by user258526
    Got the following production code below, I'm using it for a new driver. portName is COM4 and this port exists on the PC (and I can connect to it with hyperterminal), so why does Javacomm throw a NoSuchPortException? COM4 shows up fine in device mgr. too final String portName = getSerialPort(); try { final CommPortIdentifier id = CommPortIdentifier.getPortIdentifier(portName); port = (SerialPort) id.open(getName(), 1000); } catch (NoSuchPortException nspe) { report(SeverityCode.LEVEL2, getName(), "PIN Pad is not connected to " + portName + " port, or the port does not exist."); return; } catch (PortInUseException piue) { report(SeverityCode.LEVEL2, getName(), portName + " port is already in-use by some other device. Reason: " + piue.getMessage()); return; }

    Read the article

  • getting a pyserial not loaded error

    - by skinnyTOD
    I'm getting a "pyserial not loaded" error with the python script fragment below (running OSX 10.7.4). I'm trying to run a python app called Myro for controlling the Parallax Scribbler2 robot - figured it would be a fun way to learn a bit of Python - but I'm not getting out of the gate here. I've searched out all the Myro help docs but like a lot in-progress open source programs, they are a moving target and conflicting, out of date, or not very specific about OSX. I have MacPorts installed and installed py27-serial without error. MacPorts lists the python versions I have installed, along with the active version: Available versions for python: none python24 python25 python25-apple python26 python26-apple python27 python27-apple (active) python32 Perhaps stuff is getting installed in the wrong places or my PATH is wrong (I don't much know what I am doing in Terminal and have probably screwed something up). Trying to find out about my sys.path - here's what I get: import sys sys.path ['', '/System/Library/Frameworks/Python.framework/Versions/2.7/lib/python27.zip', '/System/Library/Frameworks/Python.framework/Versions/2.7/lib/python2.7', '/System/Library/Frameworks/Python.framework/Versions/2.7/lib/python2.7/plat-darwin', '/System/Library/Frameworks/Python.framework/Versions/2.7/lib/python2.7/plat-mac', '/System/Library/Frameworks/Python.framework/Versions/2.7/lib/python2.7/plat-mac/lib-scriptpackages', '/System/Library/Frameworks/Python.framework/Versions/2.7/Extras/lib/python', '/System/Library/Frameworks/Python.framework/Versions/2.7/lib/python2.7/lib-tk', '/System/Library/Frameworks/Python.framework/Versions/2.7/lib/python2.7/lib-old', '/System/Library/Frameworks/Python.framework/Versions/2.7/lib/python2.7/lib-dynload', '/System/Library/Frameworks/Python.framework/Versions/2.7/Extras/lib/python/PyObjC', '/Library/Python/2.7/site-packages'] Is that a mess? Can I fix it? Anyway, thanks for reading this far. Here's the python bit that is throwing the error. The error occurs on 'try import serial'. # Global variable robot, to set SerialPort() robot = None pythonVer = "?" rbString = None ptString = None statusText = None # Now, let's import things import urllib import tempfile import os, sys, time try: import serial except: print("WARNING: pyserial not loaded: can't upgrade!") sys.exit() try: input = raw_input # Python 2.x except: pass # Python 3 and better, input is defined try: from tkinter import * pythonver = "3" except: try: from Tkinter import * pythonver = "2" except: pythonver = "?"

    Read the article

  • Update the Progress bar using winforms c#

    - by karthik
    There is a functionality in my module, where the user can scan the number of serial ports in the system and when the user clicks "Auto scan" button, the code will have to go through each serial port and send a test message and wait for the reply. I am using Progress bar control to show process of autoscan. For which i need to pass the value to "x" and "Y" in my code to update the bar. How can i pass the value since my code is already in a foreach loop for getting the serialports. Y = should pass the value of total number of serial ports X = should iterate through each port and pass the value Hope i am clear with req. private void backgroundWorker1_DoWork(object sender, DoWorkEventArgs e) { string strAckData = ""; foreach (SerialPort sp in comPortsList) { sp.Open(); string sendData = "Auto scan"; sp.Write(sendData); strAckData += "Connection live on port " + sp.ReadExisting() + "\n"; sp.Close(); double dIndex = (double)x; **//How to pass the value here ?** double dTotal = (double)y; **//How to pass the value here ?** double dProgressPercentage = (dIndex / dTotal); int iProgressPercentage = (int)(dProgressPercentage * 100); // update the progress bar backgroundWorker1.ReportProgress(iProgressPercentage); } richTextBox1.Invoke(new MethodInvoker(delegate { richTextBox1.Text = strAckData; })); } private void backgroundWorker1_ProgressChanged(object sender, ProgressChangedEventArgs e) { ProgressBar.Value = e.ProgressPercentage; } private void backgroundWorker1_RunWorkerCompleted(object sender, RunWorkerCompletedEventArgs e) { StatusLabel.Text = "Auto Scan completed"; }

    Read the article

  • how to do display text message from cellphone to textbox

    - by Jiggy Degamo
    I am just making a project automated polling system using sms but i just a beginner of serial communication i have seen a code on the net so i apply it as my guide just a simple text message and display it on the textbox it connects but the provlem is its didn't display on the textbox. here is the code below please help me why it didn't display and please give me a cite that have a tutorial of serial communication using vb.net Imports System.IO.Ports Public Class Form1 Dim inputData As String = "" Private WithEvents serialPort1 As New IO.Ports.SerialPort Public Event DataReceived As IO.Ports.SerialDataReceivedEventHandler Private Sub Form1_FormClosed(ByVal sender As Object, ByVal e As System.Windows.Forms.FormClosedEventArgs) Handles Me.FormClosed ' Close the Serial Port serialPort1.Close() End Sub Private Sub Form1_Load(ByVal sender As Object, ByVal e As System.EventArgs) Handles Me.Load 'Set values for some properties serialPort1.PortName = "COM10" serialPort1.BaudRate = 2400 SerialPort1.Parity = IO.Ports.Parity.None SerialPort1.DataBits = 8 SerialPort1.StopBits = IO.Ports.StopBits.One SerialPort1.Handshake = IO.Ports.Handshake.None SerialPort1.RtsEnable = True ' Open the Serial Port SerialPort1.Open() 'Writes data to the Serial Port output buffer If SerialPort1.IsOpen = True Then SerialPort1.Write("MicroCommand") End If End Sub ' Receive data from the Serial Port 'Show received data on UI controls and do something Public Sub DoUpdate() TextBox1.Text = TextBox1.Text & inputData End Sub Private Sub serialPort1_DataReceived(ByVal sender As Object, ByVal e As System.IO.Ports.SerialDataReceivedEventArgs) Handles serialPort1.DataReceived inputData = serialPort1.ReadExisting 'or serialPort1.ReadLine Me.Invoke(New EventHandler(AddressOf DoUpdate)) End Sub End Class

    Read the article

  • serial port does not exist in current context: c#

    - by I__
    here's the code: using System; using System.Collections.Generic; using System.ComponentModel; using System.Data; using System.Drawing; using System.Linq; using System.Text; using System.Windows.Forms; using System.Threading; namespace WindowsFormsApplication1 { public partial class Form1 : Form { public Form1() { InitializeComponent(); } public class ThreadWork { private static SerialPort serialPort1; public static void DoWork() { serialPort1.Open(); serialPort1.Write("AT+CMGF=1\r\n"); //Thread.Sleep(500); serialPort1.Write("AT+CNMI=2,2\r\n"); //Thread.Sleep(500); serialPort1.Write("AT+CSCA=\"+4790002100\"\r\n"); //Thread.Sleep(500); serialPort1.DataReceived += serialPort1_DataReceived_1; } } private void Form1_Load(object sender, EventArgs e) { ThreadStart myThreadDelegate = new ThreadStart(ThreadWork.DoWork); Thread myThread = new Thread(myThreadDelegate); myThread.Start(); } private void serialPort1_DataReceived_1(object sender, System.IO.Ports.SerialDataReceivedEventArgs e) { string response = serialPort1.ReadLine(); this.BeginInvoke(new MethodInvoker(() => textBox1.AppendText(response + "\r\n"))); } } } and i get an error on this line: string response = serialPort1.ReadLine(); it says:: Error 1 The name 'serialPort1' does not exist in the current context C:\Users\alexluvsdanielle\AppData\Local\Temporary Projects\WindowsFormsApplication1\Form1.cs 44 31 WindowsFormsApplication1 what am i doing wrong?

    Read the article

  • Error with threads during automatic testing on TeamCity 5

    - by yeyeyerman
    Hello, I'm having some problems executing the tests of the application I'm developing. All the tests execute normally with ReSharper and in NCover. However, the execution of one of these tests in TeamCity is generating an error. This test initializes two objects, the object under test and a simulator of a real object. Both objects will communicate throug a serial link in a representation of the real scenario. ObjectSimulator r_simulator = new ObjectSimulator(...); ObjectDriver r_driver = new ObjectDriver(...); Assert.IsTrue(r_driver.Connect() == ErrorCode.Success); The simulator just do the following in the constructor public class ObjectSimulator { ... public ObjectSimulator() { // serial port configuration m_port = new SerialPort(); m_port.DataReceived += DataReceivedEvent; } ... } The main object has two threads. The main thread of the application and a timer to refresh a watchdog timer in the real object. public ErrorCode Connect() { ... StartSynchroTimer(); Thread.Sleep(4); // to check if the timer is working properly ... } The problem is comming from the Thread.Sleep() call, as when I remove it everything works. It seems like the ObjectSimulator also sleeps and doesn't receive the DataReceived event. How can I resolve this issue?

    Read the article

  • Error with `Thread.Sleep` during automatic testing on TeamCity 5

    - by yeyeyerman
    Hello, I'm having some problems executing the tests of the application I'm developing. All the tests execute normally with ReSharper and in NCover. However, the execution of one of these tests in TeamCity is generating an error. This test initializes two objects, the object under test and a simulator of a real object. Both objects will communicate throug a serial link in a representation of the real scenario. ObjectSimulator r_simulator = new ObjectSimulator(...); ObjectDriver r_driver = new ObjectDriver(...); Assert.IsTrue(r_driver.Connect() == ErrorCode.Success); The simulator just do the following in the constructor public class ObjectSimulator { ... public ObjectSimulator() { // serial port configuration m_port = new SerialPort(); m_port.DataReceived += DataReceivedEvent; } ... } The main object has two threads. The main thread of the application and a timer to refresh a watchdog timer in the real object. public ErrorCode Connect() { ... StartSynchroTimer(); Thread.Sleep(4); // to check if the timer is working properly ... } The problem seems to be comming from the Thread.Sleep() call, as when I remove it everything works. The ObjectSimulator somehow doesn't execute the DataReceived event callback. How can I resolve this issue?

    Read the article

  • Qt Serial Port Errors - Data not getting read

    - by user2970546
    I'm trying to read a serial port with the Qt SerialPort library. I can read the data using HyperTerminal. In Qt I used the following code to try and do the same thing. Qt says the the port has been opened correctly, but for some reason, the bytesAvailable from the serial port is always 0. serial.setPortName("COM20"); if (serial.open(QIODevice::ReadOnly)) qDebug() << "Opened port " << endl; else qDebug() << "Unable to open port" << endl; serial.setDataBits(QSerialPort::Data8); serial.setParity(QSerialPort::EvenParity); serial.setBaudRate(QSerialPort::Baud115200); qDebug() << "Is open?? " << serial.isOpen(); // Wait unit serial port data is ready while (!serial.bytesAvailable()) { //qDebug() << serial.bytesAvailable()<<endl; continue; } QByteArray data = serial.read(100); qDebug() << "This is the data -" << data << endl; serial.close(); In comparison, MATLAB code with the same structure as the above code, successfully manages to read the serial port data %Serial Port Grapher - Shurjo Banerjee s = serial('COM20'); s.BaudRate = 460800; s.Parity = 'even'; try input('Ready to begin?'); catch end fopen(s); fh = figure(); hold on; t = 1; while (s.BytesAvailable <= 0) continue end a = fread(s, 1) old_t = 1; old_a = a; while true if (s.BytesAvailable > 0) a = fread(s, 1) figure(fh) t = t + 1; plot([old_t t], [old_a a]); old_t = t; old_a = a; end end fclose(s);

    Read the article

  • C# Different class objects in one list

    - by jeah_wicer
    I have looked around some now to find a solution to this problem. I found several ways that could solve it but to be honest I didn't realize which of the ways that would be considered the "right" C# or OOP way of solving it. My goal is not only to solve the problems but also to develop a good set of code standards and I'm fairly sure there's a standard way to handle this problem. Let's say I have 2 types of printer hardwares with their respective classes and ways of communicating: PrinterType1, PrinterType2. I would also like to be able to later on add another type if neccessary. One step up in abstraction those have much in common. It should be possible to send a string to each one of them as an example. They both have variables in common and variables unique to each class. (One for instance communicates via COM-port and has such an object, while the other one communicates via TCP and has such an object). I would however like to just implement a List of all those printers and be able to go through the list and perform things as "Send(string message)" on all Printers regardless of type. I would also like to access variables like "PrinterList[0].Name" that are the same for both objects, however I would also at some places like to access data that is specific to the object itself (For instance in the settings window of the application where the COM-port name is set for one object and the IP/port number for another). So, in short something like: In common: Name Send() Specific to PrinterType1: Port Specific to PrinterType2: IP And I wish to, for instance, do Send() on all objects regardless of type and the number of objects present. I've read about polymorphism, Generics, interfaces and such, but I would like to know how this, in my eyes basic, problem typically would be dealt with in C# (and/or OOP in general). I actually did try to make a base class, but it didn't quite seem right to me. For instance I have no use of a "string Send(string Message)" function in the base class itself. So why would I define one there that needs to be overridden in the derived classes when I would never use the function in the base class ever in the first place? I'm really thankful for any answers. People around here seem very knowledgeable and this place has provided me with many solutions earlier. Now I finally have an account to answer and vote with too. EDIT: To additionally explain, I would also like to be able to access the objects of the actual printertype. For instance the Port variable in PrinterType1 which is a SerialPort object. I would like to access it like: PrinterList[0].Port.Open() and have access to the full range of functionality of the underlaying port. At the same time I would like to call generic functions that work in the same way for the different objects (but with different implementations): foreach (printer in Printers) printer.Send(message)

    Read the article

  • Problem receving in RXTX

    - by drhorrible
    I've been using RXTX for about a year now, without too many problems. I just started a new program to interact with a new piece of hardware, so I reused the connect() method I've used on my other projects, but I have a weird problem I've never seen before. The Problem The device works fine, because when I connect with hyperterminal, I send things and receive what I expect, and Serial Port Monitor(SPM) reflects this. However, when I run the simple hyperterminal-clone I wrote to diagnose the problem I'm having with my main app, bytes are sent, according to SPM, but nothing is received, and my SerialPortEventListener never fires. Even when I check for available data in the main loop, reader.ready() returns false. If I ignore this check, then I get an exception, details below. Relevant section of connect() method // Configure and open port port = (SerialPort) CommPortIdentifier.getPortIdentifier(name) .open(owner,1000) port.setSerialPortParams(baud, databits, stopbits, parity); port.setFlowControlMode(fc_mode); final BufferedReader br = new BufferedReader( new InputStreamReader( port.getInputStream(), "US-ASCII")); // Add listener to print received characters to screen port.addEventListener(new SerialPortEventListener(){ public void serialEvent(SerialPortEvent ev) { try { System.out.println("Received: "+br.readLine()); } catch (IOException e) { e.printStackTrace(); } } }); port.notifyOnDataAvailable(); Exception java.io.IOException: Underlying input stream returned zero bytes at sun.nio.cs.StreamDecoder.readBytes(StreamDecoder.java:268) at sun.nio.cs.StreamDecoder.implRead(StreamDecoder.java:306) at sun.nio.cs.StreamDecoder.read(StreamDecoder.java:158) at java.io.InputStreamReader.read(InputStreamReader.java:167) at java.io.BufferedReader.fill(BufferedReader.java:136) at java.io.BufferedReader.read(BufferedReader.java:157) at <my code> The big question (again) I think I've eliminated all possible hardware problems, so what could be wrong with my code, or the RXTX library? Edit: something interesting When I open hyperterminal after sending a bunch of commands from java that should have gotten responses, all of the responses appear immediately, as if they had been put in the buffer somewhere, but unavailable. Edit 2: Tried something new, same results I ran the code example found here, with the same results. No data came in, but when I switched to a new program, it came all at once. Edit 3 The hardware is fine, and even a different computer has the same problem. I am not using any sort of USB adapter. I've started using PortMon, too, and it's giving me some interesting results. Hyperterminal and RXTX are not using the same settings, and RXTX always polls the port, unlike HyperTerminal, but I still can't see what settings would affect this. As soon as I can isolate the configuration from the constant polling, I'll post my PortMon logs. Edit 4 Is it possible that some sort of Windows update in the last 3 months could have caused this? It has screwed up one of my MATLAB mex-based programs once. Edit 5 I've also noticed some things that are different between HyperTerminal, RXTX, and a separate program I found that communicates with the device (but doesn't do what I want, which is why I'm rolling my own program) HyperTerminal - set to no flow control, but Serial Port Monitor's RTS and DTR indicators are green Other program - not sure what settings it thinks it's using, but only SPM's RTS indicator is green RXTX - no matter what flow control I set, only SPM's CTS and DTR indicators are on. From Serial Port Monitor's help files (paraphrased): the indicators display the state of the serial control lines RTS - Request To Send CTS - Clear To Send DTR - Data Terminal Ready

    Read the article