  • How to implement a virtual server running Ubuntu inside a fileserver in windows?

    - by user541445
    I work in a company that has some limitations regarding their budget. They need client/server aplication. I can code the aplication, I've made mini tests on primordial applications that work. The thing is that they only have fileservers, and the application they need must be concurrent compliant, so the database must be in their local network (Fileserver is the only choice). So far, I have explored almost any option available, starting with: Desktop databases. Access (We have a license)(But concurreny is just not effective, besides it's a windows software, yuck). Sqlite (Nice, but since the information they manage is a lot, I've performed some concurrency tests with INSERTs and doing SELECTS at the same time). It fails, somehow it just stops inserting. Open office Base (I dismember a base office only to see that it was a file mode HSQLDB). I've tried, not concurrent at all. Etc (You name the Open source Desktop Database manager, and yes, I've tried that one.) Server databases Call me a stubborn person, but reading some server databases documentation say that their databases will work in a file mode. I've tried a lot of products. Postgres, MySQL, FireBird, H2, Derby, Oracle Express, IBM DB2 Express, etc. So, I really need a hand here, I've been doing this install/delete/depression thing with a lot of databases for 3 weeks, until I got with a crazy idea and I just came here to express it. So, my question comes down to this: Installing a light virtual OS software like Virtual PC and then installing in there a Server OS like an Ubuntu server inside that virtual software will work? Will it work 24/7 or when I close the virtual pc software? Will this work in a fileserver? Any suggestion, answer, critic to the place I work, crazy new concurrent database that will work in fileserver will be most than welcome.

    Read the article

  • Can't access shared folder of win8/win7 machine - Error code: 0x80004005. Unspecified Error

    - by ruslan
    It's ironic that I, software engineer with 12 years of experience, continue to have this problem from one version of Windows to another without being able to achive consistent result (sometimes it works). Here it goes again. I have a machine with Win8 Consumer Preview. It doesn't really matter that it's win8. I had same issue with win7 before. On given machine I created local admin user with same name and password I have on second PC (the machine I'm typing this from now). I have two questions to you guys. Why I'm not able to access C$ share of win8 machine from another Win7 machine? I get error that C$ doesn't exist even though it does. Why I'm not able to access share named "test" in Win8 for which Permission set to Full for Everyone. When I attempt to access it from Win7 machine I'm asked to enter username and password. After entering administrator credentials I get error "Windows cannot access \192.168.1.123\test. Error code: 0x80004005. Unspecified Error". Windows Firewall is disabled on Win8 machine for both Private and Public networks. Guest account is disabled. Built-in admin account is enabled. Machine is pingable from other machines.

    Read the article

  • Map path server with workgroup to other server with domain

    - by bzamfir
    I have the following situation, and I need some help to setup properly I have two VPS (hosted with the same provider, maximumasp). Server A is 2008R2, set with WORKGROUP, and server B is 2012, set with domain, maximumasp.local. On server A I have an old web app, which uses a special folder, c:\MyUploads, to store uploaded files. App is using this using an appSetting. It will be kept running for a while for safety / compatibility reasons. I installed a new version of the application on server B, running under AppPoolIdentity. Both instances of the app (A and B) will connect to the same database, so I need them to share also the access to upload folder c:\MyUploads. How should I setup the app on machine B to access the folder c:\MyUploads ? My idea is to share the folder as \A\MyUploads, and then map it to server B. But the problem is, I don't know to give Read/write to c:\MyUploads on machine A to IIS AppPools\ on machine B I was trying a test, and shared the c:\MyUploads to Everyone, ReadWrite. I was able to access it from machine B using \\MyUploads But when app from machine B tried to access a file, it gave error. Any idea how can I accomplish this? Some advice on best practices for such situation would be great. Thank you

    Read the article

  • WNetAddConnection2 from a Windows Service

    - by Flavio
    I'm trying to connect to a remote password protected shared folder from a Windows service, which runs as LocalSystem account. It seems that the LocalSystem account is unable to directly access password-protected network shares using WNetAddConnection2() or similar calls. Can anyone confirm this? I've read that impersonating an administrator user might be the way to go. I've tried using LogonUser() and ImpersonateLoggedOnUser() before WNetAddConnection2(), it appears that the mount of the network path succeeds, but then actual accesses (e.g. enumerating of files in remote folder) fail. Any ideas? Thanks.

    Read the article

  • Network Authentication when running exe from WMI

    - by Andy
    Hi, I have a C# exe that needs to be run using WMI and access a network share. However, when I access the share I get an UnauthorizedAccessException. If I run the exe directly the share is accessible. I am using the same user account in both cases. There are two parts to my application, a GUI client that runs on a local PC and a backend process that runs on a remote PC. When the client needs to connect to the backend it first launches the remote process using WMI (code reproduced below). The remote process does a number of things including accessing a network share using Directory.GetDirectories() and reports back to the client. When the remote process is launched automatically by the client using WMI, it cannot access the network share. However, if I connect to the remote machine using Remote Desktop and manually launch the backend process, access to the network share succeeds. The user specifed in the WMI call and the user logged in for the Remote Desktop session are the same, so the permissions should be the same, shouldn't they? I see in the MSDN entry for Directory.Exists() it states "The Exists method does not perform network authentication. If you query an existing network share without being pre-authenticated, the Exists method will return false." I assume this is related? How can I ensure the user is authenticated correctly in a WMI session? ConnectionOptions opts = new ConnectionOptions(); opts.Username = username; opts.Password = password; ManagementPath path = new ManagementPath(string.Format("\\\\{0}\\root\\cimv2:Win32_Process", remoteHost)); ManagementScope scope = new ManagementScope(path, opts); scope.Connect(); ObjectGetOptions getOpts = new ObjectGetOptions(); using (ManagementClass mngClass = new ManagementClass(scope, path, getOpts)) { ManagementBaseObject inParams = mngClass.GetMethodParameters("Create"); inParams["CommandLine"] = commandLine; ManagementBaseObject outParams = mngClass.InvokeMethod("Create", inParams, null); }

    Read the article

  • Ram cache on Windows Server 2008

    - by Jonas Lincoln
    Scenario: We have a file cluster on a UNC share. A couple of IIS web servers serve files from this UNC share. This is done through a IIS-module, and this module does not use the built-in IIS-caching feature. We'd like to cache the files from the UNC share in a ram disk. So far, we've found this product: http://www.superspeed.com/servers/supercache.php Are there other products that can help us cache the files from the UNC-share in ram?

    Read the article

  • what's the UNC path for local computer from a remote machine ?

    - by KaluSingh Gabbar
    I am writing a small utility program in IronPython to install applications on remote machine using managementclass which uses WMI. Now, the script would install an application on Machine_B from Machine_A, it works fine as long as you have the msi file on the local drive of the Target machine (Machine_B, in this case). I want to be able to do same thing with .msi file being on the Host (Machine_A) machine. network_scope = r"\\%Machine_B\root\cimv2" scope = ManagementScope(network_scope, options) scope.Connect() mp = ManagementPath("Win32_Product") ogo = ObjectGetOptions() mc = ManagementClass(scope, mp, ogo) inParams = mc.GetMethodParameters ("Install") inParams["PackageLocation"] = r"C:\installs\python-3.1.1.msi" inParams["AllUsers"] = True retVal = mc.InvokeMethod ("Install", inParams, None) print retVal ["ReturnValue"].ToString() PROBLEM : [Machine A] --- Where I am running the script, and want to host the .msi file [Machine B] --- where I want to install the application So, How can I define the UNC path for local machine ? what will be inParams["PackageLocation"] = ??

    Read the article

  • Find a part of UNC path and put in a variable?

    - by Refracted Paladin
    I am trying to peel off the last part of a unc path that is being passed and put it in a variable to use in a method further down the line. Example path would be -- \\ourfileserver\remoteuploads\countyfoldername\personfoldername How do I peel just the countyfoldername out of that? I had thought to try var th = e.FullPath.LastIndexOf('\\'); var whichFolder = folderPath.Substring(th); but that is an escape character and it doesn't like @ either. Is this even the right direction?

    Read the article

  • 404 Error Hosting WCF Service via IIS 7.5 Shared Content

    - by Chad Gruka
    We're attempting to host a WCF Service (.NET 3.5 SP1) using Shared Content on IIS 7.5. At the moment it's returning a 404 error. My assumption at this point is that WCF can not be hosted via a UNC path (See workaroundHosting WCF service in IIS6 using UNC). Steps I've taken: - Established a FullTrust to/with the UNC path. - The service works hosting it on a local disk. - A basic HTML page renders without issue from the UNC path. - A ASPX page renders without issue from the UNC path. - Explicitly set "Full Control" permissions to the user running the service. The reason for using Shared Content in IIS 7.5 to host this WCF Service, and several other websites, in a web farm. Using Shared Content avoids the need for file replication between the nodes in the farm. (Note we are also using Shared Configuration to support this environment.)

    Read the article

  • Access Denied on LAN IIS Access via Integrated Authentication

    - by Pharao2k
    I have an IIS 7.5 (Win2k8R2) Webserver, which publishes an UNC Share (on a Fileserver) with restricted access. The AppPool Identity is a Domain User-Account with read access to mentioned UNC path. Authentication modes are set to Anonymous and Integration Authentication. When I access the path via localhost from the Webserver itself, it works, but if I try the Hostname or IP from either the Webserver or a Client, I get three authentication prompts (does not accept my credentials) and a 401.3 Unauthorized error message (but it states that I am logged in as my normal credentials which definitely have access rights to the UNC path and its files). Security Zone is set to Local Intranet. Sysiniternals Process Monitor lists CreateFile operations on the UNC path (and other existing files in it) with Access Denied and Impersonating on the correct credentials. I don't understand why it is not working, it seems to use the correct credentials on every step on the way but fails with is operations.

    Read the article

  • Is my hard drive about to die?

    - by Hristo Deshev
    I have two hard drives set up as a RAID 1 array on my server (Linux, software RAID using mdadm) and one of them just got me this "present" in syslog: Nov 23 02:05:29 h2 kernel: [7305215.338153] ata1.00: exception Emask 0x0 SAct 0x1 SErr 0x0 action 0x0 Nov 23 02:05:29 h2 kernel: [7305215.338178] ata1.00: irq_stat 0x40000008 Nov 23 02:05:29 h2 kernel: [7305215.338197] ata1.00: failed command: READ FPDMA QUEUED Nov 23 02:05:29 h2 kernel: [7305215.338220] ata1.00: cmd 60/08:00:d8:df:da/00:00:3a:00:00/40 tag 0 ncq 4096 in Nov 23 02:05:29 h2 kernel: [7305215.338221] res 41/40:08:d8:df:da/00:00:3a:00:00/00 Emask 0x409 (media error) <F> Nov 23 02:05:29 h2 kernel: [7305215.338287] ata1.00: status: { DRDY ERR } Nov 23 02:05:29 h2 kernel: [7305215.338305] ata1.00: error: { UNC } Nov 23 02:05:29 h2 kernel: [7305215.358901] ata1.00: configured for UDMA/133 Nov 23 02:05:32 h2 kernel: [7305218.269054] ata1.00: exception Emask 0x0 SAct 0x1 SErr 0x0 action 0x0 Nov 23 02:05:32 h2 kernel: [7305218.269081] ata1.00: irq_stat 0x40000008 Nov 23 02:05:32 h2 kernel: [7305218.269101] ata1.00: failed command: READ FPDMA QUEUED Nov 23 02:05:32 h2 kernel: [7305218.269125] ata1.00: cmd 60/08:00:d8:df:da/00:00:3a:00:00/40 tag 0 ncq 4096 in Nov 23 02:05:32 h2 kernel: [7305218.269126] res 41/40:08:d8:df:da/00:00:3a:00:00/00 Emask 0x409 (media error) <F> Nov 23 02:05:32 h2 kernel: [7305218.269196] ata1.00: status: { DRDY ERR } Nov 23 02:05:32 h2 kernel: [7305218.269215] ata1.00: error: { UNC } Nov 23 02:05:32 h2 kernel: [7305218.341565] ata1.00: configured for UDMA/133 Nov 23 02:05:35 h2 kernel: [7305221.193342] ata1.00: exception Emask 0x0 SAct 0x1 SErr 0x0 action 0x0 Nov 23 02:05:35 h2 kernel: [7305221.193368] ata1.00: irq_stat 0x40000008 Nov 23 02:05:35 h2 kernel: [7305221.193386] ata1.00: failed command: READ FPDMA QUEUED Nov 23 02:05:35 h2 kernel: [7305221.193408] ata1.00: cmd 60/08:00:d8:df:da/00:00:3a:00:00/40 tag 0 ncq 4096 in Nov 23 02:05:35 h2 kernel: [7305221.193409] res 41/40:08:d8:df:da/00:00:3a:00:00/00 Emask 0x409 (media error) <F> Nov 23 02:05:35 h2 kernel: [7305221.193474] ata1.00: status: { DRDY ERR } Nov 23 02:05:35 h2 kernel: [7305221.193491] ata1.00: error: { UNC } Nov 23 02:05:35 h2 kernel: [7305221.388404] ata1.00: configured for UDMA/133 Nov 23 02:05:38 h2 kernel: [7305224.426316] ata1.00: exception Emask 0x0 SAct 0x1 SErr 0x0 action 0x0 Nov 23 02:05:38 h2 kernel: [7305224.426343] ata1.00: irq_stat 0x40000008 Nov 23 02:05:38 h2 kernel: [7305224.426363] ata1.00: failed command: READ FPDMA QUEUED Nov 23 02:05:38 h2 kernel: [7305224.426387] ata1.00: cmd 60/08:00:d8:df:da/00:00:3a:00:00/40 tag 0 ncq 4096 in Nov 23 02:05:38 h2 kernel: [7305224.426388] res 41/40:08:d8:df:da/00:00:3a:00:00/00 Emask 0x409 (media error) <F> Nov 23 02:05:38 h2 kernel: [7305224.426459] ata1.00: status: { DRDY ERR } Nov 23 02:05:38 h2 kernel: [7305224.426478] ata1.00: error: { UNC } Nov 23 02:05:38 h2 kernel: [7305224.498133] ata1.00: configured for UDMA/133 Nov 23 02:05:41 h2 kernel: [7305227.400583] ata1.00: exception Emask 0x0 SAct 0x1 SErr 0x0 action 0x0 Nov 23 02:05:41 h2 kernel: [7305227.400608] ata1.00: irq_stat 0x40000008 Nov 23 02:05:41 h2 kernel: [7305227.400627] ata1.00: failed command: READ FPDMA QUEUED Nov 23 02:05:41 h2 kernel: [7305227.400649] ata1.00: cmd 60/08:00:d8:df:da/00:00:3a:00:00/40 tag 0 ncq 4096 in Nov 23 02:05:41 h2 kernel: [7305227.400650] res 41/40:08:d8:df:da/00:00:3a:00:00/00 Emask 0x409 (media error) <F> Nov 23 02:05:41 h2 kernel: [7305227.400716] ata1.00: status: { DRDY ERR } Nov 23 02:05:41 h2 kernel: [7305227.400734] ata1.00: error: { UNC } Nov 23 02:05:41 h2 kernel: [7305227.472432] ata1.00: configured for UDMA/133 From what I read so far, I am not sure if read errors mean that a hard drive is dying on me (no write errors so far). I've had hard drive errors in the past and those always had errors about failing to write to specific sectors in the logs. Not this time. Should I be replacing the drive? Could something else be causing the problem? I've scheduled a smartctl -t long test that will finish in a couple of hours. I hope this will give me some more info.

    Read the article

  • Group Policy: Block access to \\localhost\C$

    - by Ryan R
    We have a restricted Windows 7 computer that hides and prevents non-admin users from accessing the C Drive. However, they are able to circumvent this by typing the following into Explorer: \\localhost\C$ How can I disable this path but allow other UNC paths. For example they are allowed to access a shared folder on a different computer. eg. \\192.168.2.1\SharedTransfer Note: Simply Enabling the Group Policy: Remove Run menu from Start Menu will not work as this blocks all UNC paths.

    Read the article

  • Hard Disk DRDY error: is it a crash

    - by pranjal
    I am using IBM Thinkpad, 1.7GHz, 512 RAM with Linux Mint 9 installed. I have two partitions in addition to root. One of the partitions became read-only yesterday, after which I rebooted my system. It is extremely slow along with DRDY Error : Is my Hard disk crashed ? Error Log while booting. Differences between boot sector and its backup. failed command : READ DMA BMDMA : stat 0X25 ata 1.00 : status : { DRDY ERR } ata 1.00 : status :{ UNC } Buffer I/O error on logical device, logical block 65467 smartctl output for the partition: mint mint # smartctl -a /dev/sda1 smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: TOSHIBA MK4026GAX RoHS Serial Number: X5LY1623T Firmware Version: PA107E User Capacity: 40,007,761,920 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 6 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Thu Feb 17 06:48:25 2011 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x84) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 153) seconds. Offline data collection capabilities: (0x1b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. No General Purpose Logging support. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 30) minutes. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0 2 Throughput_Performance 0x0005 100 100 050 Pre-fail Offline - 0 3 Spin_Up_Time 0x0027 100 100 001 Pre-fail Always - 310 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 3968 5 Reallocated_Sector_Ct 0x0033 100 100 050 Pre-fail Always - 40 7 Seek_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0 8 Seek_Time_Performance 0x0005 100 100 050 Pre-fail Offline - 0 9 Power_On_Hours 0x0032 082 082 000 Old_age Always - 7257 10 Spin_Retry_Count 0x0033 179 100 030 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 3484 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 489 193 Load_Cycle_Count 0x0032 064 064 000 Old_age Always - 367150 194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 36 (Lifetime Min/Max 14/57) 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 33 197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 82 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 1 199 UDMA_CRC_Error_Count 0x0032 200 253 000 Old_age Always - 0 220 Disk_Shift 0x0002 100 100 000 Old_age Always - 101 222 Loaded_Hours 0x0032 085 085 000 Old_age Always - 6146 223 Load_Retry_Count 0x0032 100 100 000 Old_age Always - 0 224 Load_Friction 0x0022 100 100 000 Old_age Always - 0 226 Load-in_Time 0x0026 100 100 000 Old_age Always - 227 240 Head_Flying_Hours 0x0001 100 100 001 Pre-fail Offline - 0 SMART Error Log Version: 1 ATA Error Count: 2371 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 2371 occurred at disk power-on lifetime: 7256 hours (302 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 05 1a 1b 00 e0 Error: UNC 5 sectors at LBA = 0x00001b1a = 6938 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 05 1a 1b 00 e0 00 00:03:10.061 READ DMA f8 00 00 00 00 00 e0 00 00:03:10.061 READ NATIVE MAX ADDRESS ec 00 00 00 00 00 a0 02 00:03:10.053 IDENTIFY DEVICE ef 03 45 00 00 00 a0 02 00:03:10.053 SET FEATURES [Set transfer mode] f8 00 00 00 00 00 e0 00 00:03:10.053 READ NATIVE MAX ADDRESS Error 2370 occurred at disk power-on lifetime: 7256 hours (302 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 05 1a 1b 00 e0 Error: UNC 5 sectors at LBA = 0x00001b1a = 6938 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 05 1a 1b 00 e0 00 00:03:03.328 READ DMA f8 00 00 00 00 00 e0 00 00:03:03.327 READ NATIVE MAX ADDRESS ec 00 00 00 00 00 a0 02 00:03:03.320 IDENTIFY DEVICE ef 03 45 00 00 00 a0 02 00:03:03.319 SET FEATURES [Set transfer mode] f8 00 00 00 00 00 e0 00 00:03:03.319 READ NATIVE MAX ADDRESS Error 2369 occurred at disk power-on lifetime: 7256 hours (302 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 05 1a 1b 00 e0 Error: UNC 5 sectors at LBA = 0x00001b1a = 6938 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 05 1a 1b 00 e0 00 00:02:56.582 READ DMA f8 00 00 00 00 00 e0 00 00:02:56.582 READ NATIVE MAX ADDRESS ec 00 00 00 00 00 a0 02 00:02:56.574 IDENTIFY DEVICE ef 03 45 00 00 00 a0 02 00:02:56.574 SET FEATURES [Set transfer mode] f8 00 00 00 00 00 e0 00 00:02:56.574 READ NATIVE MAX ADDRESS Error 2368 occurred at disk power-on lifetime: 7256 hours (302 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 05 1a 1b 00 e0 Error: UNC 5 sectors at LBA = 0x00001b1a = 6938 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 05 1a 1b 00 e0 00 00:02:49.809 READ DMA f8 00 00 00 00 00 e0 00 00:02:49.809 READ NATIVE MAX ADDRESS ec 00 00 00 00 00 a0 02 00:02:49.801 IDENTIFY DEVICE ef 03 45 00 00 00 a0 02 00:02:49.801 SET FEATURES [Set transfer mode] f8 00 00 00 00 00 e0 00 00:02:49.801 READ NATIVE MAX ADDRESS Error 2367 occurred at disk power-on lifetime: 7256 hours (302 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 05 1a 1b 00 e0 Error: UNC 5 sectors at LBA = 0x00001b1a = 6938 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 05 1a 1b 00 e0 00 00:02:43.056 READ DMA f8 00 00 00 00 00 e0 00 00:02:43.056 READ NATIVE MAX ADDRESS ec 00 00 00 00 00 a0 02 00:02:43.048 IDENTIFY DEVICE ef 03 45 00 00 00 a0 02 00:02:43.048 SET FEATURES [Set transfer mode] f8 00 00 00 00 00 e0 00 00:02:43.047 READ NATIVE MAX ADDRESS SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] Device does not support Selective Self Tests/Logging Do I need to get a new Hard Disk my PC ?

    Read the article

  • Ubuntu hard disk problem

    - by Henadzy
    Hello! I have got the error with a hard disk on Ubuntu 9.10. It slows down my system, applications have not been responding for a long time. But when I mount and use filesystem which placed on this hard disk at other computer it works properly. disk: SAMSUNG HD161HJ (SATA) syslog: Apr 25 00:28:25 vare6gin kernel: [ 885.773839] ata3.00: exception Emask 0x1 SAct 0x1e SErr 0x0 action 0x6 frozen Apr 25 00:28:25 vare6gin kernel: [ 885.773845] ata3.00: Ata error. fis:0x21 Apr 25 00:28:25 vare6gin kernel: [ 885.773861] ata3.00: cmd 60/08:08:3f:00:ad/00:00:10:00:00/40 tag 1 ncq 4096 in Apr 25 00:28:25 vare6gin kernel: [ 885.773864] res 51/40:24:67:c8:91/40:00:05:00:00/40 Emask 0x9 (media error) Apr 25 00:28:25 vare6gin kernel: [ 885.773871] ata3.00: status: { DRDY ERR } Apr 25 00:28:25 vare6gin kernel: [ 885.773877] ata3.00: error: { UNC } Apr 25 00:28:25 vare6gin kernel: [ 885.773890] ata3.00: cmd 60/18:10:9f:6b:ed/00:00:0e:00:00/40 tag 2 ncq 12288 in Apr 25 00:28:25 vare6gin kernel: [ 885.773893] res 51/40:24:67:c8:91/40:00:05:00:00/40 Emask 0x9 (media error) Apr 25 00:28:25 vare6gin kernel: [ 885.773900] ata3.00: status: { DRDY ERR } Apr 25 00:28:25 vare6gin kernel: [ 885.773904] ata3.00: error: { UNC } Apr 25 00:28:25 vare6gin kernel: [ 885.773918] ata3.00: cmd 60/08:18:3f:5f:ed/00:00:0e:00:00/40 tag 3 ncq 4096 in Apr 25 00:28:25 vare6gin kernel: [ 885.773921] res 51/40:24:67:c8:91/40:00:05:00:00/40 Emask 0x9 (media error) Apr 25 00:28:25 vare6gin kernel: [ 885.773927] ata3.00: status: { DRDY ERR } Apr 25 00:28:25 vare6gin kernel: [ 885.773932] ata3.00: error: { UNC } Apr 25 00:28:25 vare6gin kernel: [ 885.773946] ata3.00: cmd 60/08:20:67:c8:91/00:00:05:00:00/40 tag 4 ncq 4096 in Apr 25 00:28:25 vare6gin kernel: [ 885.773948] res 51/40:24:67:c8:91/40:00:05:00:00/40 Emask 0x9 (media error) Apr 25 00:28:25 vare6gin kernel: [ 885.773955] ata3.00: status: { DRDY ERR } Apr 25 00:28:25 vare6gin kernel: [ 885.773960] ata3.00: error: { UNC } Apr 25 00:28:25 vare6gin kernel: [ 885.773970] ata3: hard resetting link Apr 25 00:28:25 vare6gin kernel: [ 885.773974] ata3: nv: skipping hardreset on occupied port Apr 25 00:28:25 vare6gin kernel: [ 886.240073] ata3: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 25 00:28:25 vare6gin kernel: [ 886.256277] ata3.00: configured for UDMA/133 Apr 25 00:28:25 vare6gin kernel: [ 886.256305] ata3: EH complete Apr 25 00:28:27 vare6gin kernel: [ 888.176088] ata3: EH in SWNCQ mode,QC:qc_active 0xF sactive 0xF Apr 25 00:28:27 vare6gin kernel: [ 888.176099] ata3: SWNCQ:qc_active 0xF defer_bits 0x0 last_issue_tag 0x3 Apr 25 00:28:27 vare6gin kernel: [ 888.176102] dhfis 0xF dmafis 0x1 sdbfis 0x0 Apr 25 00:28:27 vare6gin kernel: [ 888.176109] ata3: ATA_REG 0x51 ERR_REG 0x40 Apr 25 00:28:27 vare6gin kernel: [ 888.176113] ata3: tag : dhfis dmafis sdbfis sacitve Apr 25 00:28:27 vare6gin kernel: [ 888.176120] ata3: tag 0x0: 1 1 0 1 Apr 25 00:28:27 vare6gin kernel: [ 888.176126] ata3: tag 0x1: 1 0 0 1 Apr 25 00:28:27 vare6gin kernel: [ 888.176131] ata3: tag 0x2: 1 0 0 1 Apr 25 00:28:27 vare6gin kernel: [ 888.176136] ata3: tag 0x3: 1 0 0 1

    Read the article

  • Ubuntu hard disk problem

    - by Henadzy
    Hello! I have got the error with a hard disk on Ubuntu 9.10. It slows down my system, applications have not been responding for a long time. But when I mount and use filesystem which placed on this hard disk at other computer it works properly. disk: SAMSUNG HD161HJ (SATA) syslog: Apr 25 00:28:25 vare6gin kernel: [ 885.773839] ata3.00: exception Emask 0x1 SAct 0x1e SErr 0x0 action 0x6 frozen Apr 25 00:28:25 vare6gin kernel: [ 885.773845] ata3.00: Ata error. fis:0x21 Apr 25 00:28:25 vare6gin kernel: [ 885.773861] ata3.00: cmd 60/08:08:3f:00:ad/00:00:10:00:00/40 tag 1 ncq 4096 in Apr 25 00:28:25 vare6gin kernel: [ 885.773864] res 51/40:24:67:c8:91/40:00:05:00:00/40 Emask 0x9 (media error) Apr 25 00:28:25 vare6gin kernel: [ 885.773871] ata3.00: status: { DRDY ERR } Apr 25 00:28:25 vare6gin kernel: [ 885.773877] ata3.00: error: { UNC } Apr 25 00:28:25 vare6gin kernel: [ 885.773890] ata3.00: cmd 60/18:10:9f:6b:ed/00:00:0e:00:00/40 tag 2 ncq 12288 in Apr 25 00:28:25 vare6gin kernel: [ 885.773893] res 51/40:24:67:c8:91/40:00:05:00:00/40 Emask 0x9 (media error) Apr 25 00:28:25 vare6gin kernel: [ 885.773900] ata3.00: status: { DRDY ERR } Apr 25 00:28:25 vare6gin kernel: [ 885.773904] ata3.00: error: { UNC } Apr 25 00:28:25 vare6gin kernel: [ 885.773918] ata3.00: cmd 60/08:18:3f:5f:ed/00:00:0e:00:00/40 tag 3 ncq 4096 in Apr 25 00:28:25 vare6gin kernel: [ 885.773921] res 51/40:24:67:c8:91/40:00:05:00:00/40 Emask 0x9 (media error) Apr 25 00:28:25 vare6gin kernel: [ 885.773927] ata3.00: status: { DRDY ERR } Apr 25 00:28:25 vare6gin kernel: [ 885.773932] ata3.00: error: { UNC } Apr 25 00:28:25 vare6gin kernel: [ 885.773946] ata3.00: cmd 60/08:20:67:c8:91/00:00:05:00:00/40 tag 4 ncq 4096 in Apr 25 00:28:25 vare6gin kernel: [ 885.773948] res 51/40:24:67:c8:91/40:00:05:00:00/40 Emask 0x9 (media error) Apr 25 00:28:25 vare6gin kernel: [ 885.773955] ata3.00: status: { DRDY ERR } Apr 25 00:28:25 vare6gin kernel: [ 885.773960] ata3.00: error: { UNC } Apr 25 00:28:25 vare6gin kernel: [ 885.773970] ata3: hard resetting link Apr 25 00:28:25 vare6gin kernel: [ 885.773974] ata3: nv: skipping hardreset on occupied port Apr 25 00:28:25 vare6gin kernel: [ 886.240073] ata3: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 25 00:28:25 vare6gin kernel: [ 886.256277] ata3.00: configured for UDMA/133 Apr 25 00:28:25 vare6gin kernel: [ 886.256305] ata3: EH complete Apr 25 00:28:27 vare6gin kernel: [ 888.176088] ata3: EH in SWNCQ mode,QC:qc_active 0xF sactive 0xF Apr 25 00:28:27 vare6gin kernel: [ 888.176099] ata3: SWNCQ:qc_active 0xF defer_bits 0x0 last_issue_tag 0x3 Apr 25 00:28:27 vare6gin kernel: [ 888.176102] dhfis 0xF dmafis 0x1 sdbfis 0x0 Apr 25 00:28:27 vare6gin kernel: [ 888.176109] ata3: ATA_REG 0x51 ERR_REG 0x40 Apr 25 00:28:27 vare6gin kernel: [ 888.176113] ata3: tag : dhfis dmafis sdbfis sacitve Apr 25 00:28:27 vare6gin kernel: [ 888.176120] ata3: tag 0x0: 1 1 0 1 Apr 25 00:28:27 vare6gin kernel: [ 888.176126] ata3: tag 0x1: 1 0 0 1 Apr 25 00:28:27 vare6gin kernel: [ 888.176131] ata3: tag 0x2: 1 0 0 1 Apr 25 00:28:27 vare6gin kernel: [ 888.176136] ata3: tag 0x3: 1 0 0 1

    Read the article

  • Accessing Network Printers from a Citrix Session:

    - by Harry
    We have an application that uses Active Reports documents. You pass a document the UNC of the printer and away it goes. We have a group that runs this application within a Citrix session and the truly networked printers function perfectly but shared printers that work well outside of Citrix become unreachable. Printers do not need to be defined on the machine running the report for the system to work. There is something in the way Critrix passes the information to the destination UNC that I don’t understand.

    Read the article

  • Accessing Network Printers from a Citrix Session:

    - by Harry
    We have an application that uses Active Reports documents. You pass a document the UNC of the printer and away it goes. We have a group that runs this application within a Citrix session and the truly networked printers function perfectly but shared printers that work well outside of Citrix become unreachable. Printers do not need to be defined on the machine running the report for the system to work. There is something in the way Critrix passes the information to the destination UNC that I don’t understand.

    Read the article

  • high load average, high wait, dmesg raid error messages (debian nfs server)

    - by John Stumbles
    Debian 6 on HP proliant (2 CPU) with raid (2*1.5T RAID1 + 2*2T RAID1 joined RAID0 to make 3.5T) running mainly nfs & imapd (plus samba for windows share & local www for previewing web pages); with local ubuntu desktop client mounting $HOME, laptops accessing imap & odd files (e.g. videos) via nfs/smb; boxes connected 100baseT or wifi via home router/switch uname -a Linux prole 2.6.32-5-686 #1 SMP Wed Jan 11 12:29:30 UTC 2012 i686 GNU/Linux Setup has been working for months but prone to intermittently going very slow (user experience on desktop mounting $HOME from server, or laptop playing videos) and now consistently so bad I've had to delve into it to try to find what's wrong(!) Server seems OK at low load e.g. (laptop) client (with $HOME on local disk) connecting to server's imapd and nfs mounting RAID to access 1 file: top shows load ~ 0.1 or less, 0 wait but when (desktop) client mounts $HOME and starts user KDE session (all accessing server) then top shows e.g. top - 13:41:17 up 3:43, 3 users, load average: 9.29, 9.55, 8.27 Tasks: 158 total, 1 running, 157 sleeping, 0 stopped, 0 zombie Cpu(s): 0.4%us, 0.4%sy, 0.0%ni, 49.0%id, 49.7%wa, 0.0%hi, 0.5%si, 0.0%st Mem: 903856k total, 851784k used, 52072k free, 171152k buffers Swap: 0k total, 0k used, 0k free, 476896k cached PID USER PR NI VIRT RES SHR S %CPU %MEM TIME+ COMMAND 3935 root 20 0 2456 1088 784 R 2 0.1 0:00.02 top 1 root 20 0 2028 680 584 S 0 0.1 0:01.14 init 2 root 20 0 0 0 0 S 0 0.0 0:00.00 kthreadd 3 root RT 0 0 0 0 S 0 0.0 0:00.00 migration/0 4 root 20 0 0 0 0 S 0 0.0 0:00.12 ksoftirqd/0 5 root RT 0 0 0 0 S 0 0.0 0:00.00 watchdog/0 6 root RT 0 0 0 0 S 0 0.0 0:00.00 migration/1 7 root 20 0 0 0 0 S 0 0.0 0:00.16 ksoftirqd/1 8 root RT 0 0 0 0 S 0 0.0 0:00.00 watchdog/1 9 root 20 0 0 0 0 S 0 0.0 0:00.42 events/0 10 root 20 0 0 0 0 S 0 0.0 0:02.26 events/1 11 root 20 0 0 0 0 S 0 0.0 0:00.00 cpuset 12 root 20 0 0 0 0 S 0 0.0 0:00.00 khelper 13 root 20 0 0 0 0 S 0 0.0 0:00.00 netns 14 root 20 0 0 0 0 S 0 0.0 0:00.00 async/mgr 15 root 20 0 0 0 0 S 0 0.0 0:00.00 pm 16 root 20 0 0 0 0 S 0 0.0 0:00.02 sync_supers 17 root 20 0 0 0 0 S 0 0.0 0:00.02 bdi-default 18 root 20 0 0 0 0 S 0 0.0 0:00.00 kintegrityd/0 19 root 20 0 0 0 0 S 0 0.0 0:00.00 kintegrityd/1 20 root 20 0 0 0 0 S 0 0.0 0:00.02 kblockd/0 21 root 20 0 0 0 0 S 0 0.0 0:00.08 kblockd/1 22 root 20 0 0 0 0 S 0 0.0 0:00.00 kacpid 23 root 20 0 0 0 0 S 0 0.0 0:00.00 kacpi_notify 24 root 20 0 0 0 0 S 0 0.0 0:00.00 kacpi_hotplug 25 root 20 0 0 0 0 S 0 0.0 0:00.00 kseriod 28 root 20 0 0 0 0 S 0 0.0 0:04.19 kondemand/0 29 root 20 0 0 0 0 S 0 0.0 0:02.93 kondemand/1 30 root 20 0 0 0 0 S 0 0.0 0:00.00 khungtaskd 31 root 20 0 0 0 0 S 0 0.0 0:00.18 kswapd0 32 root 25 5 0 0 0 S 0 0.0 0:00.00 ksmd 33 root 20 0 0 0 0 S 0 0.0 0:00.00 aio/0 34 root 20 0 0 0 0 S 0 0.0 0:00.00 aio/1 35 root 20 0 0 0 0 S 0 0.0 0:00.00 crypto/0 36 root 20 0 0 0 0 S 0 0.0 0:00.00 crypto/1 203 root 20 0 0 0 0 S 0 0.0 0:00.00 ksuspend_usbd 204 root 20 0 0 0 0 S 0 0.0 0:00.00 khubd 205 root 20 0 0 0 0 S 0 0.0 0:00.00 ata/0 206 root 20 0 0 0 0 S 0 0.0 0:00.00 ata/1 207 root 20 0 0 0 0 S 0 0.0 0:00.14 ata_aux 208 root 20 0 0 0 0 S 0 0.0 0:00.01 scsi_eh_0 dmesg suggests there's a disk problem: .............. (previous episode) [13276.966004] raid1:md0: read error corrected (8 sectors at 489900360 on sdc7) [13276.966043] raid1: sdb7: redirecting sector 489898312 to another mirror [13279.569186] ata4.00: exception Emask 0x0 SAct 0x1 SErr 0x0 action 0x0 [13279.569211] ata4.00: irq_stat 0x40000008 [13279.569230] ata4.00: failed command: READ FPDMA QUEUED [13279.569257] ata4.00: cmd 60/08:00:00:6a:05/00:00:23:00:00/40 tag 0 ncq 4096 in [13279.569262] res 41/40:00:05:6a:05/00:00:23:00:00/40 Emask 0x409 (media error) <F> [13279.569306] ata4.00: status: { DRDY ERR } [13279.569321] ata4.00: error: { UNC } [13279.575362] ata4.00: configured for UDMA/133 [13279.575388] ata4: EH complete [13283.169224] ata4.00: exception Emask 0x0 SAct 0x1 SErr 0x0 action 0x0 [13283.169246] ata4.00: irq_stat 0x40000008 [13283.169263] ata4.00: failed command: READ FPDMA QUEUED [13283.169289] ata4.00: cmd 60/08:00:00:6a:05/00:00:23:00:00/40 tag 0 ncq 4096 in [13283.169294] res 41/40:00:07:6a:05/00:00:23:00:00/40 Emask 0x409 (media error) <F> [13283.169331] ata4.00: status: { DRDY ERR } [13283.169345] ata4.00: error: { UNC } [13283.176071] ata4.00: configured for UDMA/133 [13283.176104] ata4: EH complete [13286.224814] ata4.00: exception Emask 0x0 SAct 0x1 SErr 0x0 action 0x0 [13286.224837] ata4.00: irq_stat 0x40000008 [13286.224853] ata4.00: failed command: READ FPDMA QUEUED [13286.224879] ata4.00: cmd 60/08:00:00:6a:05/00:00:23:00:00/40 tag 0 ncq 4096 in [13286.224884] res 41/40:00:06:6a:05/00:00:23:00:00/40 Emask 0x409 (media error) <F> [13286.224922] ata4.00: status: { DRDY ERR } [13286.224935] ata4.00: error: { UNC } [13286.231277] ata4.00: configured for UDMA/133 [13286.231303] ata4: EH complete [13288.802623] ata4.00: exception Emask 0x0 SAct 0x1 SErr 0x0 action 0x0 [13288.802646] ata4.00: irq_stat 0x40000008 [13288.802662] ata4.00: failed command: READ FPDMA QUEUED [13288.802688] ata4.00: cmd 60/08:00:00:6a:05/00:00:23:00:00/40 tag 0 ncq 4096 in [13288.802693] res 41/40:00:05:6a:05/00:00:23:00:00/40 Emask 0x409 (media error) <F> [13288.802731] ata4.00: status: { DRDY ERR } [13288.802745] ata4.00: error: { UNC } [13288.808901] ata4.00: configured for UDMA/133 [13288.808927] ata4: EH complete [13291.380430] ata4.00: exception Emask 0x0 SAct 0x1 SErr 0x0 action 0x0 [13291.380453] ata4.00: irq_stat 0x40000008 [13291.380470] ata4.00: failed command: READ FPDMA QUEUED [13291.380496] ata4.00: cmd 60/08:00:00:6a:05/00:00:23:00:00/40 tag 0 ncq 4096 in [13291.380501] res 41/40:00:05:6a:05/00:00:23:00:00/40 Emask 0x409 (media error) <F> [13291.380577] ata4.00: status: { DRDY ERR } [13291.380594] ata4.00: error: { UNC } [13291.386517] ata4.00: configured for UDMA/133 [13291.386543] ata4: EH complete [13294.347147] ata4.00: exception Emask 0x0 SAct 0x1 SErr 0x0 action 0x0 [13294.347169] ata4.00: irq_stat 0x40000008 [13294.347186] ata4.00: failed command: READ FPDMA QUEUED [13294.347211] ata4.00: cmd 60/08:00:00:6a:05/00:00:23:00:00/40 tag 0 ncq 4096 in [13294.347217] res 41/40:00:06:6a:05/00:00:23:00:00/40 Emask 0x409 (media error) <F> [13294.347254] ata4.00: status: { DRDY ERR } [13294.347268] ata4.00: error: { UNC } [13294.353556] ata4.00: configured for UDMA/133 [13294.353583] sd 3:0:0:0: [sdc] Unhandled sense code [13294.353590] sd 3:0:0:0: [sdc] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE [13294.353599] sd 3:0:0:0: [sdc] Sense Key : Medium Error [current] [descriptor] [13294.353610] Descriptor sense data with sense descriptors (in hex): [13294.353616] 72 03 11 04 00 00 00 0c 00 0a 80 00 00 00 00 00 [13294.353635] 23 05 6a 06 [13294.353644] sd 3:0:0:0: [sdc] Add. Sense: Unrecovered read error - auto reallocate failed [13294.353657] sd 3:0:0:0: [sdc] CDB: Read(10): 28 00 23 05 6a 00 00 00 08 00 [13294.353675] end_request: I/O error, dev sdc, sector 587557382 [13294.353726] ata4: EH complete [13294.366953] raid1:md0: read error corrected (8 sectors at 489900544 on sdc7) [13294.366992] raid1: sdc7: redirecting sector 489898496 to another mirror and they're happening quite frequently, which I guess is liable to account for the performance problem(?) # dmesg | grep mirror [12433.561822] raid1: sdc7: redirecting sector 489900464 to another mirror [12449.428933] raid1: sdb7: redirecting sector 489900504 to another mirror [12464.807016] raid1: sdb7: redirecting sector 489900512 to another mirror [12480.196222] raid1: sdb7: redirecting sector 489900520 to another mirror [12495.585413] raid1: sdb7: redirecting sector 489900528 to another mirror [12510.974424] raid1: sdb7: redirecting sector 489900536 to another mirror [12526.374933] raid1: sdb7: redirecting sector 489900544 to another mirror [12542.619938] raid1: sdc7: redirecting sector 489900608 to another mirror [12559.431328] raid1: sdc7: redirecting sector 489900616 to another mirror [12576.553866] raid1: sdc7: redirecting sector 489900624 to another mirror [12592.065265] raid1: sdc7: redirecting sector 489900632 to another mirror [12607.621121] raid1: sdc7: redirecting sector 489900640 to another mirror [12623.165856] raid1: sdc7: redirecting sector 489900648 to another mirror [12638.699474] raid1: sdc7: redirecting sector 489900656 to another mirror [12655.610881] raid1: sdc7: redirecting sector 489900664 to another mirror [12672.255617] raid1: sdc7: redirecting sector 489900672 to another mirror [12672.288746] raid1: sdc7: redirecting sector 489900680 to another mirror [12672.332376] raid1: sdc7: redirecting sector 489900688 to another mirror [12672.362935] raid1: sdc7: redirecting sector 489900696 to another mirror [12674.201177] raid1: sdc7: redirecting sector 489900704 to another mirror [12698.045050] raid1: sdc7: redirecting sector 489900712 to another mirror [12698.089309] raid1: sdc7: redirecting sector 489900720 to another mirror [12698.111999] raid1: sdc7: redirecting sector 489900728 to another mirror [12698.134006] raid1: sdc7: redirecting sector 489900736 to another mirror [12719.034376] raid1: sdc7: redirecting sector 489900744 to another mirror [12734.545775] raid1: sdc7: redirecting sector 489900752 to another mirror [12734.590014] raid1: sdc7: redirecting sector 489900760 to another mirror [12734.624050] raid1: sdc7: redirecting sector 489900768 to another mirror [12734.647308] raid1: sdc7: redirecting sector 489900776 to another mirror [12734.664657] raid1: sdc7: redirecting sector 489900784 to another mirror [12734.710642] raid1: sdc7: redirecting sector 489900792 to another mirror [12734.721919] raid1: sdc7: redirecting sector 489900800 to another mirror [12734.744732] raid1: sdc7: redirecting sector 489900808 to another mirror [12734.779330] raid1: sdc7: redirecting sector 489900816 to another mirror [12782.604564] raid1: sdb7: redirecting sector 1242934216 to another mirror [12798.264153] raid1: sdc7: redirecting sector 1242935080 to another mirror [13245.832193] raid1: sdb7: redirecting sector 489898296 to another mirror [13261.376929] raid1: sdb7: redirecting sector 489898304 to another mirror [13276.966043] raid1: sdb7: redirecting sector 489898312 to another mirror [13294.366992] raid1: sdc7: redirecting sector 489898496 to another mirror although the arrays are still running on all disks - they haven't given up on any yet: # cat /proc/mdstat Personalities : [raid1] [raid0] md10 : active raid0 md0[0] md1[1] 3368770048 blocks super 1.2 512k chunks md1 : active raid1 sde2[2] sdd2[1] 1464087824 blocks super 1.2 [2/2] [UU] md0 : active raid1 sdb7[0] sdc7[2] 1904684920 blocks super 1.2 [2/2] [UU] unused devices: <none> So I think I have some idea what the problem is but I am not a linux sysadmin expert by the remotest stretch of the imagination and would really appreciate some clue checking here with my diagnosis and what do I need to do: obviously I need to source another drive for sdc. (I'm guessing I could buy a larger drive if the price is right: I'm thinking that one day I'll need to grow the size of the array and that would be one less drive to replace with a larger one) then use mdadm to fail out the existing sdc, remove it and fit the new drive fdisk the new drive with the same size partition for the array as the old one had use mdadm to add the new drive into the array that sound OK?

    Read the article

  • Ubuntu hard disk problem

    - by Henadzy
    Hello! I have got the error with a hard disk on Ubuntu 9.10. It slows down my system, applications have not been responding for a long time. But when I mount and use filesystem which placed on this hard disk at other computer it works properly. disk: SAMSUNG HD161HJ (SATA) syslog: Apr 25 00:28:25 vare6gin kernel: [ 885.773839] ata3.00: exception Emask 0x1 SAct 0x1e SErr 0x0 action 0x6 frozen Apr 25 00:28:25 vare6gin kernel: [ 885.773845] ata3.00: Ata error. fis:0x21 Apr 25 00:28:25 vare6gin kernel: [ 885.773861] ata3.00: cmd 60/08:08:3f:00:ad/00:00:10:00:00/40 tag 1 ncq 4096 in Apr 25 00:28:25 vare6gin kernel: [ 885.773864] res 51/40:24:67:c8:91/40:00:05:00:00/40 Emask 0x9 (media error) Apr 25 00:28:25 vare6gin kernel: [ 885.773871] ata3.00: status: { DRDY ERR } Apr 25 00:28:25 vare6gin kernel: [ 885.773877] ata3.00: error: { UNC } Apr 25 00:28:25 vare6gin kernel: [ 885.773890] ata3.00: cmd 60/18:10:9f:6b:ed/00:00:0e:00:00/40 tag 2 ncq 12288 in Apr 25 00:28:25 vare6gin kernel: [ 885.773893] res 51/40:24:67:c8:91/40:00:05:00:00/40 Emask 0x9 (media error) Apr 25 00:28:25 vare6gin kernel: [ 885.773900] ata3.00: status: { DRDY ERR } Apr 25 00:28:25 vare6gin kernel: [ 885.773904] ata3.00: error: { UNC } Apr 25 00:28:25 vare6gin kernel: [ 885.773918] ata3.00: cmd 60/08:18:3f:5f:ed/00:00:0e:00:00/40 tag 3 ncq 4096 in Apr 25 00:28:25 vare6gin kernel: [ 885.773921] res 51/40:24:67:c8:91/40:00:05:00:00/40 Emask 0x9 (media error) Apr 25 00:28:25 vare6gin kernel: [ 885.773927] ata3.00: status: { DRDY ERR } Apr 25 00:28:25 vare6gin kernel: [ 885.773932] ata3.00: error: { UNC } Apr 25 00:28:25 vare6gin kernel: [ 885.773946] ata3.00: cmd 60/08:20:67:c8:91/00:00:05:00:00/40 tag 4 ncq 4096 in Apr 25 00:28:25 vare6gin kernel: [ 885.773948] res 51/40:24:67:c8:91/40:00:05:00:00/40 Emask 0x9 (media error) Apr 25 00:28:25 vare6gin kernel: [ 885.773955] ata3.00: status: { DRDY ERR } Apr 25 00:28:25 vare6gin kernel: [ 885.773960] ata3.00: error: { UNC } Apr 25 00:28:25 vare6gin kernel: [ 885.773970] ata3: hard resetting link Apr 25 00:28:25 vare6gin kernel: [ 885.773974] ata3: nv: skipping hardreset on occupied port Apr 25 00:28:25 vare6gin kernel: [ 886.240073] ata3: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 25 00:28:25 vare6gin kernel: [ 886.256277] ata3.00: configured for UDMA/133 Apr 25 00:28:25 vare6gin kernel: [ 886.256305] ata3: EH complete Apr 25 00:28:27 vare6gin kernel: [ 888.176088] ata3: EH in SWNCQ mode,QC:qc_active 0xF sactive 0xF Apr 25 00:28:27 vare6gin kernel: [ 888.176099] ata3: SWNCQ:qc_active 0xF defer_bits 0x0 last_issue_tag 0x3 Apr 25 00:28:27 vare6gin kernel: [ 888.176102] dhfis 0xF dmafis 0x1 sdbfis 0x0 Apr 25 00:28:27 vare6gin kernel: [ 888.176109] ata3: ATA_REG 0x51 ERR_REG 0x40 Apr 25 00:28:27 vare6gin kernel: [ 888.176113] ata3: tag : dhfis dmafis sdbfis sacitve Apr 25 00:28:27 vare6gin kernel: [ 888.176120] ata3: tag 0x0: 1 1 0 1 Apr 25 00:28:27 vare6gin kernel: [ 888.176126] ata3: tag 0x1: 1 0 0 1 Apr 25 00:28:27 vare6gin kernel: [ 888.176131] ata3: tag 0x2: 1 0 0 1 Apr 25 00:28:27 vare6gin kernel: [ 888.176136] ata3: tag 0x3: 1 0 0 1

    Read the article

  • IIS7 web farm - local or shared content?

    - by rbeier
    We're setting up an IIS7 web farm with two servers. Should each server have its own local copy of the content, or should they pull content directly from a UNC share? What are the pros and cons of each approach? We currently have a single live server WEB1, with content stored locally on a separate partition. A job periodically syncs WEB1 to a standby server WEB2, using robocopy for content and msdeploy for config. If WEB1 goes down, Nagios notifies us, and we manually run a script to move the IP addresses to WEB2's network interface. Both servers are actually VMs running on separate VMWare ESX 4 hosts. The servers are domain-joined. We have around 50-60 live sites on WEB1 - mostly ASP.NET, with a few that are just static HTML. Most are low-traffic "microsites". A few have moderate traffic, but none are massive. We'd like to change this so both WEB1 and WEB2 are actively serving content. This is mainly for reliability - if WEB1 goes down, we don't want to have to manually intervene to fail things over. Spreading the load is also nice, but the load is not high enough right now for us to need this. We're planning to configure our firewall to balance traffic across the two servers. It will detect when a server goes down and will send all the traffic to the remaining live server. We're planning to use sticky sessions for now... eventually we may move to SQL Server session state and stateless load balancing. But we need a way for the servers to share content. We were originally planning to move all the content to a UNC share. Our storage provider says they can set up a highly available SMB share for us. So if we go the UNC route, the storage shouldn't be a single point of failure. But we're wondering about the downsides to this approach: We'll need to change the physical paths for each site and virtual directory. There are also some projects that have absolute paths in their web.config files - we'll have to update those as well. We'll need to create a domain user for the web servers to access the share, and grant that user appropriate permissions. I haven't looked into this yet - I'm not sure if the application pool identity needs to be changed to this user, or if there's another way to tell IIS to use this account when connecting to the share. Sites will no longer be able to access their content if there's ever an Active Directory problem. In general, it just seems a lot more complicated, with more moving parts that could break. Our storage provider would create a volume for us on their redundant SAN. If I understand correctly, this SAN volume would be mounted on a VM running in their redundant VMWare environment; this VM would then expose the SMB share to our web servers. On the other hand, a benefit of the shared content approach is that we'd only need to deploy code to one place, and there would never be a temporary inconsistency between multiple copies of the content. This thread is pretty interesting, though some of these people are working at a much larger scale. I've just been discussing content so far, but we also need to think about configuration. I don't know if we can just use DFS replication for the applicationHost.config and other files, or if it's best to use the shared configuration feature with the config on a UNC share. What do you think? Thanks for your help, Richard

    Read the article

  • T4 Template error - Assembly Directive cannot locate referenced assembly in Visual Studio 2010 proje

    - by CodeSniper
    I ran into the following error recently in Visual Studio 2010 while trying to port Phil Haack’s excellent T4CSS template which was originally built for Visual Studio 2008.   The Problem Error Compiling transformation: Metadata file 'dotless.Core' could not be found In “T4 speak”, this simply means that you have an Assembly directive in your T4 template but the T4 engine was not able to locate or load the referenced assembly. In the case of the T4CSS Template, this was a showstopper for making it work in Visual Studio 2010. On a side note: The T4CSS template is a sweet little wrapper to allow you to use DotLessCss to generate static .css files from .less files rather than using their default HttpHandler or command-line tool.    If you haven't tried DotLessCSS yet, go check it out now!  In short, it is a tool that allows you to templatize and program your CSS files so that you can use variables, expressions, and mixins within your CSS which enables rapid changes and a lot of developer-flexibility as you evolve your CSS and UI. Back to our regularly scheduled program… Anyhow, this post isn't about DotLessCss, its about the T4 Templates and the errors I ran into when converting them from Visual Studio 2008 to Visual Studio 2010. In VS2010, there were quite a few changes to the T4 Template Engine; most were excellent changes, but this one bit me with T4CSS: “Project assemblies are no longer used to resolve template assembly directives.” In VS2008, if you wanted to reference a custom assembly in your T4 Template (.tt file) you would simply right click on your project, choose Add Reference and select that assembly.  Afterwards you were allowed to use the following syntax in your T4 template to tell it to look at the local references: <#@ assembly name="dotless.Core.dll" #> This told the engine to look in the “usual place” for the assembly, which is your project references. However, this is exactly what they changed in VS2010.  They now basically sandbox the T4 Engine to keep your T4 assemblies separate from your project assemblies.  This can come in handy if you want to support different versions of an assembly referenced both by your T4 templates and your project. Who broke the build?  Oh, Microsoft Did! In our case, this change causes a problem since the templates are no longer compatible when upgrading to VS 2010 – thus its a breaking change.  So, how do we make this work in VS 2010? Luckily, Microsoft now offers several options for referencing assemblies from T4 Templates: GAC your assemblies and use Namespace Reference or Fully Qualified Type Name Use a hard-coded Fully Qualified UNC path Copy assembly to Visual Studio "Public Assemblies Folder" and use Namespace Reference or Fully Qualified Type Name.  Use or Define a Windows Environment Variable to build a Fully Qualified UNC path. Use a Visual Studio Macro to build a Fully Qualified UNC path. Option #1 & 2 were already supported in Visual Studio 2008, so if you want to keep your templates compatible with both Visual Studio versions, then you would have to adopt one of these approaches. Yakkety Yak, use the GAC! Option #1 requires an additional pre-build step to GAC the referenced assembly, which could be a pain.  But, if you go that route, then after you GAC, all you need is a simple type name or namespace reference such as: <#@ assembly name="dotless.Core" #> Hard Coding aint that hard! The other option of using hard-coded paths in Option #2 is pretty impractical in most situations since each developer would have to use the same local project folder paths, or modify this setting each time for their local machines as well as for production deployment.  However, if you want to go that route, simply use the following assembly directive style: <#@ assembly name="C:\Code\Lib\dotless.Core.dll" #> Lets go Public! Option #3, the Visual Studio Public Assemblies Folder, is the recommended place to put commonly used tools and libraries that are only needed for Visual Studio.  Think of it like a VS-only GAC.  This is likely the best place for something like dotLessCSS and is my preferred solution.  However, you will need to either use an installer or a pre-build action to copy the assembly to the right folder location.   Normally this is located at:  C:\Program Files (x86)\Microsoft Visual Studio 10.0\Common7\IDE\PublicAssemblies Once you have copied your assembly there, you use the type name or namespace syntax again: <#@ assembly name="dotless.Core" #> Save the Environment! Option #4, using a Windows Environment Variable, is interesting for enterprise use where you may have standard locations for files, but less useful for demo-code, frameworks, and products where you don't have control over the local system.  The syntax for including a environment variable in your assembly directive looks like the following, just as you would expect: <#@ assembly name="%mypath%\dotless.Core.dll" #> “mypath” is a Windows environment variable you setup that points to some fully qualified UNC path on your system.  In the right situation this can be a great solution such as one where you use a msi installer for deployment, or where you have a pre-existing environment variable you can re-use. OMG Macros! Finally, Option #5 is a very nice option if you want to keep your T4 template’s assembly reference local and relative to the project or solution without muddying-up your dev environment or GAC with extra deployments.  An example looks like this: <#@ assembly name="$(SolutionDir)lib\dotless.Core.dll" #> In this example, I’m using the “SolutionDir” VS macro so I can reference an assembly in a “/lib” folder at the root of the solution.   This is just one of the many macros you can use.  If you are familiar with creating Pre/Post-build Event scripts, you can use its dialog to look at all of the different VS macros available. This option gives the best solution for local assemblies without the hassle of extra installers or other setup before the build.   However, its still not compatible with Visual Studio 2008, so if you have a T4 Template you want to use with both, then you may have to create multiple .tt files, one for each IDE version, or require the developer to set a value in the .tt file manually.   I’m not sure if T4 Templates support any form of compiler switches like “#if (VS2010)”  statements, but it would definitely be nice in this case to switch between this option and one of the ones more compatible with VS 2008. Conclusion As you can see, we went from 3 options with Visual Studio 2008, to 5 options (plus one problem) with Visual Studio 2010.  As a whole, I think the changes are great, but the short-term growing pains during the migration may be annoying until we get used to our new found power. Hopefully this all made sense and was helpful to you.  If nothing else, I’ll just use it as a reference the next time I need to port a T4 template to Visual Studio 2010.  Happy T4 templating, and “May the fourth be with you!”

    Read the article

  • Failing Sata HDD

    - by DaveCol
    I think my HDD is fried... Could someone confirm or help me restore it? I was using Hardware RAID 1 Configuration [2 x 160GB SATA HDD] on a CentOS 4 Installation. All of a sudden I started seeing bad sectors on the second HDD which stopped being mirrored. I have removed the RAID array and have tested with SMART which showed the following error: 187 Unknown_Attribute 0x003a 001 001 051 Old_age Always FAILING_NOW 4645 I have no clue what this means, or if I can recover from it. Could someone give me some ideas on how to fix this, or what HDD to get to replace this? Complete SMART report: Smartctl version 5.33 [i686-redhat-linux-gnu] Copyright (C) 2002-4 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: GB0160CAABV Serial Number: 6RX58NAA Firmware Version: HPG1 User Capacity: 160,041,885,696 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 7 ATA Standard is: ATA/ATAPI-7 T13 1532D revision 4a Local Time is: Tue Oct 19 13:42:42 2010 COT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED See vendor-specific Attribute list for marginal Attributes. General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 433) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 54) minutes. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 100 253 006 Pre-fail Always - 0 3 Spin_Up_Time 0x0002 097 097 000 Old_age Always - 0 4 Start_Stop_Count 0x0033 100 100 020 Pre-fail Always - 152 5 Reallocated_Sector_Ct 0x0033 095 095 036 Pre-fail Always - 214 7 Seek_Error_Rate 0x000f 078 060 030 Pre-fail Always - 73109713 9 Power_On_Hours 0x0032 083 083 000 Old_age Always - 15133 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0033 100 100 020 Pre-fail Always - 154 184 Unknown_Attribute 0x0032 038 038 000 Old_age Always - 62 187 Unknown_Attribute 0x003a 001 001 051 Old_age Always FAILING_NOW 4645 189 Unknown_Attribute 0x0022 100 100 000 Old_age Always - 0 190 Unknown_Attribute 0x001a 061 055 000 Old_age Always - 656408615 194 Temperature_Celsius 0x0000 039 045 000 Old_age Offline - 39 (Lifetime Min/Max 0/22) 195 Hardware_ECC_Recovered 0x0032 070 059 000 Old_age Always - 12605265 197 Current_Pending_Sector 0x0000 100 100 000 Old_age Offline - 1 198 Offline_Uncorrectable 0x0000 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0000 200 200 000 Old_age Offline - 62 SMART Error Log Version: 1 ATA Error Count: 4645 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 4645 occurred at disk power-on lifetime: 15132 hours (630 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 7b 86 b1 ea Error: UNC at LBA = 0x0ab1867b = 179406459 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 02 7b 86 b1 ea 00 00:38:52.796 READ DMA ec 03 45 00 00 00 a0 00 00:38:52.796 IDENTIFY DEVICE ef 03 45 00 00 00 a0 00 00:38:52.794 SET FEATURES [Set transfer mode] ec 00 00 7b 86 b1 a0 00 00:38:49.991 IDENTIFY DEVICE c8 00 04 79 86 b1 ea 00 00:38:49.935 READ DMA Error 4644 occurred at disk power-on lifetime: 15132 hours (630 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 7b 86 b1 ea Error: UNC at LBA = 0x0ab1867b = 179406459 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 04 79 86 b1 ea 00 00:38:41.517 READ DMA ec 03 45 00 00 00 a0 00 00:38:41.515 IDENTIFY DEVICE ef 03 45 00 00 00 a0 00 00:38:41.515 SET FEATURES [Set transfer mode] ec 00 00 7b 86 b1 a0 00 00:38:49.991 IDENTIFY DEVICE c8 00 06 77 86 b1 ea 00 00:38:49.935 READ DMA Error 4643 occurred at disk power-on lifetime: 15132 hours (630 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 7b 86 b1 ea Error: UNC at LBA = 0x0ab1867b = 179406459 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 06 77 86 b1 ea 00 00:38:41.517 READ DMA ec 03 45 00 00 00 a0 00 00:38:41.515 IDENTIFY DEVICE ef 03 45 00 00 00 a0 00 00:38:41.515 SET FEATURES [Set transfer mode] ec 00 00 7b 86 b1 a0 00 00:38:41.513 IDENTIFY DEVICE c8 00 06 77 86 b1 ea 00 00:38:38.706 READ DMA Error 4642 occurred at disk power-on lifetime: 15132 hours (630 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 7b 86 b1 ea Error: UNC at LBA = 0x0ab1867b = 179406459 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 06 77 86 b1 ea 00 00:38:41.517 READ DMA ec 03 45 00 00 00 a0 00 00:38:41.515 IDENTIFY DEVICE ef 03 45 00 00 00 a0 00 00:38:41.515 SET FEATURES [Set transfer mode] ec 00 00 7b 86 b1 a0 00 00:38:41.513 IDENTIFY DEVICE c8 00 06 77 86 b1 ea 00 00:38:38.706 READ DMA Error 4641 occurred at disk power-on lifetime: 15132 hours (630 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 7b 86 b1 ea Error: UNC at LBA = 0x0ab1867b = 179406459 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 06 77 86 b1 ea 00 00:38:41.517 READ DMA ec 03 45 00 00 00 a0 00 00:38:41.515 IDENTIFY DEVICE ef 03 45 00 00 00 a0 00 00:38:41.515 SET FEATURES [Set transfer mode] ec 00 00 7b 86 b1 a0 00 00:38:41.513 IDENTIFY DEVICE c8 00 06 77 86 b1 ea 00 00:38:38.706 READ DMA SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 15131 - # 2 Short offline Completed without error 00% 15131 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.

    Read the article

< Previous Page | 1 2 3 4 5 6 7 8 9 10  | Next Page >