Search Results

Search found 3228 results on 130 pages for 'vb6 conversion'.

Page 4/130 | < Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >

  • vb6 api/spy question

    - by Fuxi
    hi all, i'm trying to control some soulseek features from VB6 - the problem is the SysTabControl32 - how can i read out which tab is selected? the api spyer only returns the SysTabcontrol32 but no tab button. thx

    Read the article

  • VB6 app not executing as scheduled task unless user is logged on

    - by Tedd Hansen
    Hi Would greatly apprechiate some help on this one! It may be a tricky one. :) Problem I have an VB6 application which is set up as scheduled task. It starts every time, but when executing CreateObject it fails if user is not logged on to computer. I am looking for information on what could cause this. Primary suspicion is that some Windows API fails. Key points Behaviour confirmed on Windows 2000, 2003, 2008 and Vista. The application executes as user X at scheduled time, executed by Windows Task Scheduler. It executes every time. Application does start! -- If user X is logged on via RDP it runs perfectly. (Note that user doesn't need to be connected, only logged on) -- If user X is not logged on to computer the application fails. Failure point Application fails when using CreateObject() to instansiate a DCOM object which is also part of the application. The DCOM objects declare .dll-references at startup (globally/on top of .bas-file) and run a small startup function. Failure must be during startup, possibly in one of the .dll-declarations. Thoughts After some Googling my initial suspicion was directed at MAPI. From what I could see MAPI required user to be logged on. The application has MAPI references. But even with all MAPI references removed it still does not work. What is the difference if an user is logged on? Registry mapping? Environment? explorer.exe is running. Isn't the user logged on when application executes as the user? What info would help? A definitive answer would be truly great. Any information regarding any VB6 feature/Windows API that could act differently depending on wether user is logged on or not would definitively help. Similar experiences may lead me in the right direction. Tips on debuggin this. Thanks! :)

    Read the article

  • Is there a vb6 decompiler?

    - by Rismo
    I lost the source code from one project I did on the company I'm working for and haven't been able to find a vb6 decompiler, does that even exists? Forgot to say that I only have the EXE. I completely forgot about this project and rescued the EXE from a user's machine.

    Read the article

  • VB6's private static in C# ?

    - by blez
    In VB6 there are local static variables that keep their values after the exit of procedure. It's like using public vars but on local block. For example: sub count() static x as integer x = x + 1 end sub After 10 calls, x will be 10. I tried to search the same thing in .NET (and even Java) but there was none. Why? Does it break the OOP model in some way, and is there a way to emulate that.

    Read the article

  • Centering fonts in VB6

    - by James Musser
    How do you determine the length of a string of text in Arial Bold font, and then center it in VB6? If not here, can you point me in a direction where I might be able to find this information? We're not using a "label" or "picture box" do print the text to the screen. We are sizing the text on the fly, and allowing the user to scale the size of our application to their liking. We write the text to screen using code.

    Read the article

  • VB6 - View Code will not display code

    - by zSysop
    Hi all, This is probably a really dumb question but i'll ask anyway. I was wondering if there was any reason as to why a form wouldn't display its code when i click "view code" from the right click context menu in vb6? It was working awhile ago so i'm kind of stumped. Thanks

    Read the article

  • VB6 code for Reading/Writing Windows Registry values

    - by Clay Nichols
    I'm looking for a good example of reading and writing to the Windows Registry using VB6. Yes, I know there are lots of mediocre examples. I spent an hour googling and testing. Some were incredibly complex, others had only some of the functions, and almost none of it had been vetted in any way (voted on). Since Stack Overflow is intended to the canonical location for answers to programming questions, it seems reasonable to post it here.

    Read the article

  • Solving Inbound Refinery PDF Conversion Issues, Part 1

    - by Kevin Smith
    Working with Inbound Refinery (IBR)  and PDF Conversion can be very frustrating. When everything is working smoothly you kind of forgot it is even there. Documents are cheeked into WebCenter Content (WCC), sent to IBR for conversion, converted to PDF, returned to WCC, and viola your Office documents have a nice PDF rendition available for viewing. Then a user checks in a bunch of password protected Word files, the conversions fail, your IBR queue starts backing up, users start calling asking why their document have not been released yet, and your spend a frustrating afternoon trying to recover and get things back running properly again. Password protected documents are one cause of PDF conversion failures, and I will cover those in a future blog post, but there are many other problems that can cause conversions to fail, especially when working with the WinNativeConverter and using the native applications, e.g. Word, to convert a document to PDF. There are other conversion options like PDFExportConverter which uses Oracle OutsideIn to convert documents directly to PDF without the need for the native applications. However, to get the best fidelity to the original document the native applications must be used. Many customers have tried PDFExportConverter, but have stayed with the native applications for conversion since the conversion results from PDFExportConverter were not as good as when the native applications are used. One problem I ran into recently, that at least has a easy solution, are Word documents that display a Show Repairs dialog when the document is opened. If you open the problem document yourself you will see this dialog. This will cause the conversion to time out. Any time the native application displays a dialog that requires user input the conversion will time out. The solution is to set add a setting for BulletProofOnCorruption to the registry for the user running Word on the IBR server. See this support note from Microsoft for details. The support note says to set the registry key under HKEY_CURRENT_USER, but since we are running IBR as a service the correct location is under HKEY_USERS\.DEFAULT. Also since in our environment we were using Office 2007, the correct registry key to use was: HKEY_USERS\.DEFAULT\Software\Microsoft\Office\11.0\Word\Options Once you have done this restart the IBR managed server and resubmit your problem document. It should now be converted successfully. For more details on IBR see the Oracle® WebCenter Content Administrator's Guide for Conversion.

    Read the article

  • Trace not working in a .NET DLL loaded from VB6 EXE

    - by Luis
    Hello I have a .NET DLL that writes to the Trace. But seems that when I call my DLL from a VB6 EXE the trace is not working. I have created an myApp.config file in the EXE folder with the trace configuration, but this does not solves the issue. I've also tried creating the Trace objects in code,but doesn't work: Dim _traceSrc as TraceSource= New TraceSource("myTraceSorce") Dim flListener As FileLogTraceListener = New FileLogTraceListener("myFileLogTraceListener") Dim tSwitch As SourceSwitch = New SourceSwitch("mySwitch") tSwitch.Level = _logLevel If I call my DLL from a .NET EXE it works, even if I dont have the app.config in the EXE folder, becusase I set it in code if the config is not found. Thanks

    Read the article

  • getting a blank data report vb6

    - by arvind
    Hi, I am new to vb6. I am working to create the invoice generation application. I am using data report to show the generated invoice. The step by step working of process is Entering the data in to Invoice and ItemsInvoice tables. Then getting the maxId using (Adodc) from the data base to show the last generated Invoice. Then passing the max Id as parameter to the data report which is showing the invoice according to the invoice id. It is working fine when I first time generate invoice. Now for 2nd invoice withou closing application I am getting a blank data report. For data report I am using dataenvironment. I am guessing the reason of blank data report is blank because there was no record for that Id. But actually the record is inserting in the database. Please help me.

    Read the article

  • Convert VB6 to C# use NDDE ? help

    - by tabvn
    i have a vb6 code i want to use http://ndde.codeplex.com/ , please help me convert to c# thanks Const TOPIC_SENSOR As String = "SeeLane|Sensor" Const TOPIC_GATE As String = "SeeLane|Gate" Const TOPIC_PIN As String = "SeeLane|Pin" Const ITEM_SENSOR_ACTIVATE As String = "Activate" Const ITEM_GATE_OPEN As String = "Open" Const ITEM_PIN_ON As String = "On" Const ITEM_PIN_OFF As String = "Off" Private Sub Form_Load() On Error GoTo NO_DDE_SERVER lblCar.LinkMode = vbLinkNotify lblLaneId.LinkMode = vbLinkManual lblName.LinkMode = vbLinkManual lblAuthorized.LinkMode = vbLinkManual lblFile.LinkMode = vbLinkManual lblConfidence.LinkMode = vbLinkManual lblType.LinkMode = vbLinkManual MsgBox "Ket noi voi thanh cong voi SeeLane !!!" Exit Sub NO_DDE_SERVER: MsgBox "Khong the ket noi voi SeeLane !(Xem chuong trinh co chay khong?)." Exit Sub End Sub Private Sub lblCar_LinkNotify() On Error Resume Next lblCar.LinkRequest lblLaneId.LinkRequest lblName.LinkRequest lblAuthorized.LinkRequest lblFile.LinkRequest lblConfidence.LinkRequest lblType.LinkRequest CheckAuthorized lblLaneId.Caption = lblLaneId.Caption + 1 End Sub Private Sub CheckAuthorized() Dim i As Integer i = lblAuthorized.Caption i = i + 1 If lblAuthorized.Caption = 1 Then lblPoke.LinkTopic = TOPIC_GATE lblPoke.LinkItem = ITEM_GATE_OPEN lblPoke = Chr(lblLaneId.Caption) lblPoke.LinkMode = vbLinkManual lblPoke.LinkPoke End If End Sub

    Read the article

  • Centralized error handling in VB6.

    - by AngryHacker
    I have the following method that all the error handlers call: Public Function ToError(strClass As String, strMethod As String) As String On Error GoTo errHandle ToError = "Err " & Err.Number & _ ", Src: " & Err.Source & _ ", Dsc: " & Err.Description & _ ", Project: " & App.Title & _ ", Class: " & strClass & _ ", Method: " & strMethod & _ ", Line: " & Erl Err.Clear exitPoint: Exit Function errHandle: oLog.AddToLog "Error in ToError Method: " & Err.Description, False Resume exitPoint End Function It turns out that because I declare an error handler in this function On Error GoTo errHandle, VB6 clears the error before I am able to record it. Is there a way to prevent the 'On Error GoTo errHandle' statement from clearing the error?

    Read the article

  • Howto troubleshoot vb6 dll 800a01ad error in c# application

    - by phq
    I have a dll that I created from a VB6 project that I am now using in a c# project. This has worked before but now when I try to return to the c# project to fix a bug, the program get a COMException stating roughly translated: Could not create an instance of COM-component with CLSID {085E3494-9F78-47D5-B0E6-FA460FD3CBED} from IClassFactory because of the following error: 800a01ad. So I try to create a new empty c# project with only one line in the main function: OurNamespace.OurClass foo = new OurNamespace.OurClass(); Which fails with the same error. I have registered the dll but that did not change the outcome of the problem. The problem only occurs on the machine I am currently at, still I'm interested to understand the problem so that I know how to fix it if it occurs on a customers computer.

    Read the article

< Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >