Search Results

Search found 1018 results on 41 pages for 'blake nic'.

Page 40/41 | < Previous Page | 36 37 38 39 40 41  | Next Page >

  • VPN Connection Causes Internal LAN Connection Loss with Server

    - by sleepisfortheweak
    I've tried configuring basic PPTP VPN at my small business using a number of different tutorials. As far as I can tell, the actual VPN connection worked fine, but upon connecting a client, the Server 'disappears' from the internal LAN. The RRAS service must be stopped before the connection is restored. My Setup: The network is simply a DSL Gateway/Router to the outside functioning as NAT/Firewall/DHCP. The server is a Win Server 2008 machine at fixed IP 192.168.1.200. The server has 1 NIC, so I used the 'custom' option when configuring RRAS. The RRAS settings should be default except that I've disabled ports for connection types I'm not using and reduced PPTP ports to 10. I've also created an address pool and disabled DHCP packet forwarding. The server only functions as a File Share and now a VPN Server. Local LAN computers all have mapped network shares to the server authenticated based on Local User/Group setup on the server. The Problem: The moment a client connects through VPN, the server 'disappears' from the local network. All mapped drives disconnect and there is no response to a ping 192.168.1.200. Even if the client disconnects, the server does not re-appear at that address until the RRAS service is stopped. I've Tried: Using an Address Pool inside and outside the local subnet. Using DCHP Relay Checking Inbound/Outbound filters (none enabled) The fact that nothing I've tried has had any effect, and that I can connect and successfully obtain an IP tells me that it's something more fundamental I'm missing. My gut tells me that it's something to do with the second IP address added by the VPN client somehow taking over the interface or traffic from the local LAN accidently getting routed to the VPN client instead of handled at the server once RRAS has become 'active' when a client connects. Hopefully this may be obvious to someone with real IT experience. I've been doing this a while and almost never been stumped. I'm starting to think it might actually be something tricky since my setup is pretty basic yet refuses to work. I'll be happy to include more info if this doesn't ring any bells right away for anyone. Thanks

    Read the article

  • MySQL performance over a (local) network much slower than I would expect

    - by user15241
    MySQL queries in my production environment are taking much longer than I would expect them too. The site in question is a fairly large Drupal site, with many modules installed. The webserver (Nginx) and database server (mysql) are hosted on separated machines, connected by a 100mbps LAN connection (hosted by Rackspace). I have the exact same site running on my laptop for development. Obviously, on my laptop, the webserver and database server are on the same box. Here are the results of my database query times: Production: Executed 291 queries in 320.33 milliseconds. (homepage) Executed 517 queries in 999.81 milliseconds. (content page) Development: Executed 316 queries in 46.28 milliseconds. (homepage) Executed 586 queries in 79.09 milliseconds. (content page) As can clearly be seen from these results, the time involved with querying the MySQL database is much shorter on my laptop, where the MySQL server is running on the same database as the web server. Why is this?! One factor must be the network latency. On average, a round trip from from the webserver to the database server takes 0.16ms (shown by ping). That must be added to every singe MySQL query. So, taking the content page example above, where there are 517 queries executed. Network latency alone will add 82ms to the total query time. However, that doesn't account for the difference I am seeing (79ms on my laptop vs 999ms on the production boxes). What other factors should I be looking at? I had thought about upgrading the NIC to a gigabit connection, but clearly there is something else involved. I have run the MySQL performance tuning script from http://www.day32.com/MySQL/ and it tells me that my database server is configured well (better than my laptop apparently). The only problem reported is "Of 4394 temp tables, 48% were created on disk". This is true in both environments and in the production environment I have even tried increasing max_heap_table_size and Current tmp_table_size to 1GB, with no change (I think this is because I have some BLOB and TEXT columns).

    Read the article

  • Bridging and iptables SNAT conflict

    - by sad_admin
    Hello I am working on a setup here and have it working with one minor exception. Devices on one side of my bridge aren't getting SNAT'd to the Internet. The Diagram / Overview: Primary_Network (Site_A) | | Internet ------- Linux_Bridge_GW (GW) | | Secondary/CoLo Site (Site_B) Here is the setup: 1.) Site_A has all the production servers and workstations. 2.) Site_B has a set of servers that we would like to fail-over to and also serve our internet facing services from. 3.) GW has two interfaces that are trunked and carrying the appropriate VLAN traffic (allow layer-2 propagation of traffic between sites) //this all works perfectly fine. 4.) The problem that is being encountered is, hosts from Site_B have their default GW at Site_A (same subnet) GW does not have IPs on the VLANs that are being passed. 5.) All hosts at Site_A can reach the Internet without problem. 6.) GW has an addresses on a subnet that is ONLY for Internet destined traffic. (This was done so that Websense would not have to parse unnecessary traffic. We use this VLAN as the monitor port's source on the switch where Websense is sitting). What I think is happening: 1.) Packet/Frame comes in on physdev at Site_B destined for Internet. 2.) Kernel sees packet, and forwards it out the other side of the bridge to that host's default GW. 3.) Site_A (containing core-network's Default-GW) sees that packet is destined for a host it doesn't know about, so it sends it to it's default GW (the linux bridge, since it's Internet bound). 4.) The kernel says "Hey, I've seen you before" and therefore doesn't do SNAT'ing on the packet and sends it out to the Internet where it's black-holed. Why I think it's happening: 1.) A tcpdump on the internet facing NIC shows the packet leaving the interface with the private address as it's source. What I would like: 1.) Have the packet SNAT'd. 2.) Something like the below would be awesome a.) packet comes in from Site_B b.) kernel sees that the packet is NOT destined for itself or any private address c.) kernel says "OK, well since you're destined for the Internet I'm going to send you out this interface rather than forward you to your normal default GW that's WAAAY over there." d.) packet comes in from internet and is sent out the appropriate bridge physdev depending on which site the host it's destined for is at. Thanks for any assistance or guidance that you are willing to offer. Best Regards, Sad Admin

    Read the article

  • External USB 3 drive not recognized

    - by ilan123
    Ubuntu 12.10 64 bit seems not to recognize my external hard disk. It is a Vantec NST-310S3 external disk enclosure with a WD 3TB drive. The disk has two NTFS partitions. My PC is a dual boot system. Under Windows 7 the hard disk works fine but I can't make it work with Ubuntu. When the drive is connected to the PC then the command sudo fdisk -l seems to hang forever. Below are the output of lsusb and cat /proc/partitions without the external drive and then with it connected. I added also the last lines of the dmesg command at the end. First without the drive: ilan@linux:~$ lsusb Bus 001 Device 002: ID 8087:0024 Intel Corp. Integrated Rate Matching Hub Bus 002 Device 002: ID 8087:0024 Intel Corp. Integrated Rate Matching Hub Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 002 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 003 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 004 Device 001: ID 1d6b:0003 Linux Foundation 3.0 root hub Bus 001 Device 003: ID 13ba:0017 Unknown PS/2 Keyboard+Mouse Adapter Bus 001 Device 004: ID 046d:c50e Logitech, Inc. Cordless Mouse Receiver Bus 001 Device 005: ID 0ac8:3420 Z-Star Microelectronics Corp. Venus USB2.0 Camera ilan@linux:~$ cat /proc/partitions major minor #blocks name 8 0 1953514584 sda 8 1 102400 sda1 8 2 629043200 sda2 8 3 367001600 sda3 8 4 1 sda4 8 5 471859200 sda5 8 6 157286400 sda6 8 7 324115456 sda7 8 8 4101120 sda8 11 0 1048575 sr0 Second with the USB 3 drive: ilan@linux:~$ lsusb Bus 001 Device 002: ID 8087:0024 Intel Corp. Integrated Rate Matching Hub Bus 002 Device 002: ID 8087:0024 Intel Corp. Integrated Rate Matching Hub Bus 004 Device 002: ID 174c:55aa ASMedia Technology Inc. Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 002 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 003 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 004 Device 001: ID 1d6b:0003 Linux Foundation 3.0 root hub Bus 001 Device 003: ID 13ba:0017 Unknown PS/2 Keyboard+Mouse Adapter Bus 001 Device 004: ID 046d:c50e Logitech, Inc. Cordless Mouse Receiver Bus 001 Device 005: ID 0ac8:3420 Z-Star Microelectronics Corp. Venus USB2.0 Camera ilan@linux:~$ cat /proc/partitions major minor #blocks name 8 0 1953514584 sda 8 1 102400 sda1 8 2 629043200 sda2 8 3 367001600 sda3 8 4 1 sda4 8 5 471859200 sda5 8 6 157286400 sda6 8 7 324115456 sda7 8 8 4101120 sda8 11 0 1048575 sr0 8 16 2930266584 sdb ilan@linux:~$ lsusb -v -s 004:002 Bus 004 Device 002: ID 174c:55aa ASMedia Technology Inc. Couldn't open device, some information will be missing Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 3.00 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 9 idVendor 0x174c ASMedia Technology Inc. idProduct 0x55aa bcdDevice 1.00 iManufacturer 2 iProduct 3 iSerial 1 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 44 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xc0 Self Powered MaxPower 0mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 2 bInterfaceClass 8 Mass Storage bInterfaceSubClass 6 SCSI bInterfaceProtocol 80 Bulk-Only iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0400 1x 1024 bytes bInterval 0 bMaxBurst 15 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x02 EP 2 OUT bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0400 1x 1024 bytes bInterval 0 bMaxBurst 15 ilan@linux:~$ sudo fdisk -l [sudo] password for ilan: Disk /dev/sda: 2000.4 GB, 2000398934016 bytes 255 heads, 63 sectors/track, 243201 cylinders, total 3907029168 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0xf1b4f1ee Device Boot Start End Blocks Id System /dev/sda1 * 2048 206847 102400 7 HPFS/NTFS/exFAT /dev/sda2 206848 1258293247 629043200 7 HPFS/NTFS/exFAT /dev/sda3 1258293248 1992296447 367001600 7 HPFS/NTFS/exFAT /dev/sda4 1992298494 3907028991 957365249 f W95 Ext'd (LBA) /dev/sda5 1992298496 2936016895 471859200 7 HPFS/NTFS/exFAT /dev/sda6 2936018944 3250591743 157286400 7 HPFS/NTFS/exFAT /dev/sda7 3250593792 3898824703 324115456 83 Linux /dev/sda8 3898826752 3907028991 4101120 82 Linux swap / Solaris dmesg output after connecting the external drive: [ 23.740567] e1000e: eth0 NIC Link is Up 1000 Mbps Full Duplex, Flow Control: Rx/Tx [ 23.740786] IPv6: ADDRCONF(NETDEV_CHANGE): eth0: link becomes ready [ 49.144673] usb 4-1: >new SuperSpeed USB device number 2 using xhci_hcd [ 49.163039] usb 4-1: >Parent hub missing LPM exit latency info. Power management will be impacted. [ 49.166789] usb 4-1: >New USB device found, idVendor=174c, idProduct=55aa [ 49.166793] usb 4-1: >New USB device strings: Mfr=2, Product=3, SerialNumber=1 [ 49.166796] usb 4-1: >Product: AS2105 [ 49.166799] usb 4-1: >Manufacturer: ASMedia [ 49.166801] usb 4-1: >SerialNumber: 0123456789ABCDEF [ 49.206372] usbcore: registered new interface driver uas [ 49.228891] Initializing USB Mass Storage driver... [ 49.229042] scsi6 : usb-storage 4-1:1.0 [ 49.229115] usbcore: registered new interface driver usb-storage [ 49.229116] USB Mass Storage support registered. [ 64.045528] scsi 6:0:0:0: >Direct-Access WDC WD30 EZRX-00MMMB0 80.0 PQ: 0 ANSI: 0 [ 64.046224] sd 6:0:0:0: >Attached scsi generic sg2 type 0 [ 64.046881] sd 6:0:0:0: >[sdb] Very big device. Trying to use READ CAPACITY(16). [ 64.047610] sd 6:0:0:0: >[sdb] 5860533168 512-byte logical blocks: (3.00 TB/2.72 TiB) [ 64.048368] sd 6:0:0:0: >[sdb] Write Protect is off [ 64.048373] sd 6:0:0:0: >[sdb] Mode Sense: 23 00 00 00 [ 64.048984] sd 6:0:0:0: >[sdb] No Caching mode page present [ 64.048987] sd 6:0:0:0: >[sdb] Assuming drive cache: write through [ 64.049297] sd 6:0:0:0: >[sdb] Very big device. Trying to use READ CAPACITY(16). [ 64.050942] sd 6:0:0:0: >[sdb] No Caching mode page present [ 64.050944] sd 6:0:0:0: >[sdb] Assuming drive cache: write through [ 94.245006] usb 4-1: >reset SuperSpeed USB device number 2 using xhci_hcd [ 94.262553] usb 4-1: >Parent hub missing LPM exit latency info. Power management will be impacted. [ 94.263805] xhci_hcd 0000:03:00.0: >xHCI xhci_drop_endpoint called with disabled ep ffff8800d37d1c00 [ 94.263808] xhci_hcd 0000:03:00.0: >xHCI xhci_drop_endpoint called with disabled ep ffff8800d37d1c40 [ 125.262722] usb 4-1: >reset SuperSpeed USB device number 2 using xhci_hcd [ 125.280304] usb 4-1: >Parent hub missing LPM exit latency info. Power management will be impacted. [ 125.281511] xhci_hcd 0000:03:00.0: >xHCI xhci_drop_endpoint called with disabled ep ffff8800d37d1c00 [ 125.281516] xhci_hcd 0000:03:00.0: >xHCI xhci_drop_endpoint called with disabled ep ffff8800d37d1c40

    Read the article

  • Best Practices - Dynamic Reconfiguration

    - by jsavit
    This post is one of a series of "best practices" notes for Oracle VM Server for SPARC (formerly named Logical Domains) Overview of dynamic Reconfiguration Oracle VM Server for SPARC supports Dynamic Reconfiguration (DR), making it possible to add or remove resources to or from a domain (virtual machine) while it is running. This is extremely useful because resources can be shifted to or from virtual machines in response to load conditions without having to reboot or interrupt running applications. For example, if an application requires more CPU capacity, you can add CPUs to improve performance, and remove them when they are no longer needed. You can use even use Dynamic Resource Management (DRM) policies that automatically add and remove CPUs to domains based on load. How it works (in broad general terms) Dynamic Reconfiguration is done in coordination with Solaris, which recognises a hypervisor request to change its virtual machine configuration and responds appropriately. In essence, Solaris receives a message saying "you now have 16 more CPUs numbered 16 to 31" or "8GB more RAM starting at address X" or "here's a new network or disk device - have fun with it". These actions take very little time. Solaris then can start using the new resource. In the case of added CPUs, that means dispatching processes and potentially binding interrupts to the new CPUs. For memory, Solaris adds the new memory pages to its "free" list and starts using them. Comparable actions occur with network and disk devices: they are recognised by Solaris and then used. Removing is the reverse process: after receiving the DR message to free specific CPUs, Solaris unbinds interrupts assigned to the CPUs and stops dispatching process threads. That takes very little time. primary # ldm list NAME STATE FLAGS CONS VCPU MEMORY UTIL UPTIME primary active -n-cv- SP 16 4G 1.0% 6d 22h 29m ldom1 active -n---- 5000 16 8G 0.9% 6h 59m primary # ldm set-core 5 ldom1 primary # ldm list NAME STATE FLAGS CONS VCPU MEMORY UTIL UPTIME primary active -n-cv- SP 16 4G 0.2% 6d 22h 29m ldom1 active -n---- 5000 40 8G 0.1% 6h 59m primary # ldm set-core 2 ldom1 primary # ldm list NAME STATE FLAGS CONS VCPU MEMORY UTIL UPTIME primary active -n-cv- SP 16 4G 1.0% 6d 22h 29m ldom1 active -n---- 5000 16 8G 0.9% 6h 59m Memory pages are vacated by copying their contents to other memory locations and wiping them clean. Solaris may have to swap memory contents to disk if the remaining RAM isn't enough to hold all the contents. For this reason, deallocating memory can take longer on a loaded system. Even on a lightly loaded system it took several 7 or 8 seconds to switch the domain below between 8GB and 24GB of RAM. primary # ldm set-mem 24g ldom1 primary # ldm list NAME STATE FLAGS CONS VCPU MEMORY UTIL UPTIME primary active -n-cv- SP 16 4G 0.1% 6d 22h 36m ldom1 active -n---- 5000 16 24G 0.2% 7h 6m primary # ldm set-mem 8g ldom1 primary # ldm list NAME STATE FLAGS CONS VCPU MEMORY UTIL UPTIME primary active -n-cv- SP 16 4G 0.7% 6d 22h 37m ldom1 active -n---- 5000 16 8G 0.3% 7h 7m What if the device is in use? (this is the anecdote that inspired this blog post) If CPU or memory is being removed, releasing it pretty straightforward, using the method described above. The resources are released, and Solaris continues with less capacity. It's not as simple with a network or I/O device: you don't want to yank a device out from underneath an application that might be using it. In the following example, I've added a virtual network device to ldom1 and want to take it away, even though it's been plumbed. primary # ldm rm-vnet vnet19 ldom1 Guest LDom returned the following reason for failing the operation: Resource Information ---------------------------------------------------------- ----------------------- /devices/virtual-devices@100/channel-devices@200/network@1 Network interface net1 VIO operation failed because device is being used in LDom ldom1 Failed to remove VNET instance That's what I call a helpful error message - telling me exactly what was wrong. In this case the problem is easily solved. I know this NIC is seen in the guest as net1 so: ldom1 # ifconfig net1 down unplumb Now I can dispose of it, and even the virtual switch I had created for it: primary # ldm rm-vnet vnet19 ldom1 primary # ldm rm-vsw primary-vsw9 If I had to take away the device disruptively, I could have used ldm rm-vnet -f but that could disrupt whoever was using it. It's better if that can be avoided. Summary Oracle VM Server for SPARC provides dynamic reconfiguration, which lets you modify a guest domain's CPU, memory and I/O configuration on the fly without reboot. You can add and remove resources as needed, and even automate this for CPUs by setting up resource policies. Taking things away can be more complicated than giving, especially for devices like disks and networks that may contain application and system state or be involved in a transaction. LDoms and Solaris cooperative work together to coordinate resource allocation and de-allocation in a safe and effective way. For best practices, use dynamic reconfiguration to make the best use of your system's resources.

    Read the article

  • ?Oracle Database 12c????Information Lifecycle Management ILM?Storage Enhancements

    - by Liu Maclean(???)
    Oracle Database 12c????Information Lifecycle Management ILM ?????????Storage Enhancements ???????? Lifecycle Management ILM ????????? Automatic Data Placement ??????, ??ADP? ?????? 12c???????Datafile??? Online Move Datafile, ????????????????datafile???????,??????????????? ????(12.1.0.1)Automatic Data Optimization?heat map????????: ????????? (CDB)?????Automatic Data Optimization?heat map Row-level policies for ADO are not supported for Temporal Validity. Partition-level ADO and compression are supported if partitioned on the end-time columns. Row-level policies for ADO are not supported for in-database archiving. Partition-level ADO and compression are supported if partitioned on the ORA_ARCHIVE_STATE column. Custom policies (user-defined functions) for ADO are not supported if the policies default at the tablespace level. ADO does not perform checks for storage space in a target tablespace when using storage tiering. ADO is not supported on tables with object types or materialized views. ADO concurrency (the number of simultaneous policy jobs for ADO) depends on the concurrency of the Oracle scheduler. If a policy job for ADO fails more than two times, then the job is marked disabled and the job must be manually enabled later. Policies for ADO are only run in the Oracle Scheduler maintenance windows. Outside of the maintenance windows all policies are stopped. The only exceptions are those jobs for rebuilding indexes in ADO offline mode. ADO has restrictions related to moving tables and table partitions. ??????row,segment???????????ADO??,?????create table?alter table?????? ????ADO??,??????????????,???????????????? storage tier , ?????????storage tier?????????, ??????????????ADO??????????? segment?row??group? ?CREATE TABLE?ALERT TABLE???ILM???,??????????????????ADO policy? ??ILM policy???????????????? ??????? ????ADO policy, ?????alter table  ???????,?????????????? CREATE TABLE sales_ado (PROD_ID NUMBER NOT NULL, CUST_ID NUMBER NOT NULL, TIME_ID DATE NOT NULL, CHANNEL_ID NUMBER NOT NULL, PROMO_ID NUMBER NOT NULL, QUANTITY_SOLD NUMBER(10,2) NOT NULL, AMOUNT_SOLD NUMBER(10,2) NOT NULL ) ILM ADD POLICY COMPRESS FOR ARCHIVE HIGH SEGMENT AFTER 6 MONTHS OF NO ACCESS; SQL> SELECT SUBSTR(policy_name,1,24) AS POLICY_NAME, policy_type, enabled 2 FROM USER_ILMPOLICIES; POLICY_NAME POLICY_TYPE ENABLED -------------------- -------------------------- -------------- P41 DATA MOVEMENT YES ALTER TABLE sales MODIFY PARTITION sales_1995 ILM ADD POLICY COMPRESS FOR ARCHIVE HIGH SEGMENT AFTER 6 MONTHS OF NO ACCESS; SELECT SUBSTR(policy_name,1,24) AS POLICY_NAME, policy_type, enabled FROM USER_ILMPOLICIES; POLICY_NAME POLICY_TYPE ENABLE ------------------------ ------------- ------ P1 DATA MOVEMENT YES P2 DATA MOVEMENT YES /* You can disable an ADO policy with the following */ ALTER TABLE sales_ado ILM DISABLE POLICY P1; /* You can delete an ADO policy with the following */ ALTER TABLE sales_ado ILM DELETE POLICY P1; /* You can disable all ADO policies with the following */ ALTER TABLE sales_ado ILM DISABLE_ALL; /* You can delete all ADO policies with the following */ ALTER TABLE sales_ado ILM DELETE_ALL; /* You can disable an ADO policy in a partition with the following */ ALTER TABLE sales MODIFY PARTITION sales_1995 ILM DISABLE POLICY P2; /* You can delete an ADO policy in a partition with the following */ ALTER TABLE sales MODIFY PARTITION sales_1995 ILM DELETE POLICY P2; ILM ???????: ?????ILM ADP????,???????: ?????? ???? activity tracking, ????2????????,???????????????????: SEGMENT-LEVEL???????????????????? ROW-LEVEL????????,??????? ????????: 1??????? SEGMENT-LEVEL activity tracking ALTER TABLE interval_sales ILM  ENABLE ACTIVITY TRACKING SEGMENT ACCESS ???????INTERVAL_SALES??segment level  activity tracking,?????????????????? 2? ??????????? ALTER TABLE emp ILM ENABLE ACTIVITY TRACKING (CREATE TIME , WRITE TIME); 3????????? ALTER TABLE emp ILM ENABLE ACTIVITY TRACKING  (READ TIME); ?12.1.0.1.0?????? ??HEAT_MAP??????????, ?????system??session?????heap_map????????????? ?????????HEAT MAP??,? ALTER SYSTEM SET HEAT_MAP = ON; ?HEAT MAP??????,??????????????????????????  ??SYSTEM?SYSAUX????????????? ???????HEAT MAP??: ALTER SYSTEM SET HEAT_MAP = OFF; ????? HEAT_MAP????, ?HEAT_MAP??? ?????????????????????? ?HEAT_MAP?????????Automatic Data Optimization (ADO)??? ??ADO??,Heat Map ?????????? ????V$HEAT_MAP_SEGMENT ??????? HEAT MAP?? SQL> select * from V$heat_map_segment; no rows selected SQL> alter session set heat_map=on; Session altered. SQL> select * from scott.emp; EMPNO ENAME JOB MGR HIREDATE SAL COMM DEPTNO ---------- ---------- --------- ---------- --------- ---------- ---------- ---------- 7369 SMITH CLERK 7902 17-DEC-80 800 20 7499 ALLEN SALESMAN 7698 20-FEB-81 1600 300 30 7521 WARD SALESMAN 7698 22-FEB-81 1250 500 30 7566 JONES MANAGER 7839 02-APR-81 2975 20 7654 MARTIN SALESMAN 7698 28-SEP-81 1250 1400 30 7698 BLAKE MANAGER 7839 01-MAY-81 2850 30 7782 CLARK MANAGER 7839 09-JUN-81 2450 10 7788 SCOTT ANALYST 7566 19-APR-87 3000 20 7839 KING PRESIDENT 17-NOV-81 5000 10 7844 TURNER SALESMAN 7698 08-SEP-81 1500 0 30 7876 ADAMS CLERK 7788 23-MAY-87 1100 20 7900 JAMES CLERK 7698 03-DEC-81 950 30 7902 FORD ANALYST 7566 03-DEC-81 3000 20 7934 MILLER CLERK 7782 23-JAN-82 1300 10 14 rows selected. SQL> select * from v$heat_map_segment; OBJECT_NAME SUBOBJECT_NAME OBJ# DATAOBJ# TRACK_TIM SEG SEG FUL LOO CON_ID -------------------- -------------------- ---------- ---------- --------- --- --- --- --- ---------- EMP 92997 92997 23-JUL-13 NO NO YES NO 0 ??v$heat_map_segment???,?v$heat_map_segment??????????????X$HEATMAPSEGMENT V$HEAT_MAP_SEGMENT displays real-time segment access information. Column Datatype Description OBJECT_NAME VARCHAR2(128) Name of the object SUBOBJECT_NAME VARCHAR2(128) Name of the subobject OBJ# NUMBER Object number DATAOBJ# NUMBER Data object number TRACK_TIME DATE Timestamp of current activity tracking SEGMENT_WRITE VARCHAR2(3) Indicates whether the segment has write access: (YES or NO) SEGMENT_READ VARCHAR2(3) Indicates whether the segment has read access: (YES or NO) FULL_SCAN VARCHAR2(3) Indicates whether the segment has full table scan: (YES or NO) LOOKUP_SCAN VARCHAR2(3) Indicates whether the segment has lookup scan: (YES or NO) CON_ID NUMBER The ID of the container to which the data pertains. Possible values include:   0: This value is used for rows containing data that pertain to the entire CDB. This value is also used for rows in non-CDBs. 1: This value is used for rows containing data that pertain to only the root n: Where n is the applicable container ID for the rows containing data The Heat Map feature is not supported in CDBs in Oracle Database 12c, so the value in this column can be ignored. ??HEAP MAP??????????????????,????DBA_HEAT_MAP_SEGMENT???????? ???????HEAT_MAP_STAT$?????? ??Automatic Data Optimization??????: ????1: SQL> alter system set heat_map=on; ?????? ????????????? scott?? http://www.askmaclean.com/archives/scott-schema-script.html SQL> grant all on dbms_lock to scott; ????? SQL> grant dba to scott; ????? @ilm_setup_basic C:\APP\XIANGBLI\ORADATA\MACLEAN\ilm.dbf @tktgilm_demo_env_setup SQL> connect scott/tiger ; ???? SQL> select count(*) from scott.employee; COUNT(*) ---------- 3072 ??? 1 ?? SQL> set serveroutput on SQL> exec print_compression_stats('SCOTT','EMPLOYEE'); Compression Stats ------------------ Uncmpressed : 3072 Adv/basic compressed : 0 Others : 0 PL/SQL ???????? ???????3072?????? ????????? ????policy ???????????? alter table employee ilm add policy row store compress advanced row after 3 days of no modification / SQL> set serveroutput on SQL> execute list_ilm_policies; -------------------------------------------------- Policies defined for SCOTT -------------------------------------------------- Object Name------ : EMPLOYEE Subobject Name--- : Object Type------ : TABLE Inherited from--- : POLICY NOT INHERITED Policy Name------ : P1 Action Type------ : COMPRESSION Scope------------ : ROW Compression level : ADVANCED Tier Tablespace-- : Condition type--- : LAST MODIFICATION TIME Condition days--- : 3 Enabled---------- : YES -------------------------------------------------- PL/SQL ???????? SQL> select sysdate from dual; SYSDATE -------------- 29-7? -13 SQL> execute set_back_chktime(get_policy_name('EMPLOYEE',null,'COMPRESSION','ROW','ADVANCED',3,null,null),'EMPLOYEE',null,6); Object check time reset ... -------------------------------------- Object Name : EMPLOYEE Object Number : 93123 D.Object Numbr : 93123 Policy Number : 1 Object chktime : 23-7? -13 08.13.42.000000 ?? Distnt chktime : 0 -------------------------------------- PL/SQL ???????? ?policy?chktime???6??, ????set_back_chktime???????????????“????”?,?????????,???????? ?????? alter system flush buffer_cache; alter system flush buffer_cache; alter system flush shared_pool; alter system flush shared_pool; SQL> execute set_window('MONDAY_WINDOW','OPEN'); Set Maint. Window OPEN ----------------------------- Window Name : MONDAY_WINDOW Enabled? : TRUE Active? : TRUE ----------------------------- PL/SQL ???????? SQL> exec dbms_lock.sleep(60) ; PL/SQL ???????? SQL> exec print_compression_stats('SCOTT', 'EMPLOYEE'); Compression Stats ------------------ Uncmpressed : 338 Adv/basic compressed : 2734 Others : 0 PL/SQL ???????? ??????????????? Adv/basic compressed : 2734 ??????? SQL> col object_name for a20 SQL> select object_id,object_name from dba_objects where object_name='EMPLOYEE'; OBJECT_ID OBJECT_NAME ---------- -------------------- 93123 EMPLOYEE SQL> execute list_ilm_policy_executions ; -------------------------------------------------- Policies execution details for SCOTT -------------------------------------------------- Policy Name------ : P22 Job Name--------- : ILMJOB48 Start time------- : 29-7? -13 08.37.45.061000 ?? End time--------- : 29-7? -13 08.37.48.629000 ?? ----------------- Object Name------ : EMPLOYEE Sub_obj Name----- : Obj Type--------- : TABLE ----------------- Exec-state------- : SELECTED FOR EXECUTION Job state-------- : COMPLETED SUCCESSFULLY Exec comments---- : Results comments- : --- -------------------------------------------------- PL/SQL ???????? ILMJOB48?????policy?JOB,?12.1.0.1??J00x???? ?MMON_SLAVE???M00x???15????????? select sample_time,program,module,action from v$active_session_history where action ='KDILM background EXEcution' order by sample_time; 29-7? -13 08.16.38.369000000 ?? ORACLE.EXE (M000) MMON_SLAVE KDILM background EXEcution 29-7? -13 08.17.38.388000000 ?? ORACLE.EXE (M000) MMON_SLAVE KDILM background EXEcution 29-7? -13 08.17.39.390000000 ?? ORACLE.EXE (M000) MMON_SLAVE KDILM background EXEcution 29-7? -13 08.23.38.681000000 ?? ORACLE.EXE (M002) MMON_SLAVE KDILM background EXEcution 29-7? -13 08.32.38.968000000 ?? ORACLE.EXE (M000) MMON_SLAVE KDILM background EXEcution 29-7? -13 08.33.39.993000000 ?? ORACLE.EXE (M003) MMON_SLAVE KDILM background EXEcution 29-7? -13 08.33.40.993000000 ?? ORACLE.EXE (M003) MMON_SLAVE KDILM background EXEcution 29-7? -13 08.36.40.066000000 ?? ORACLE.EXE (M000) MMON_SLAVE KDILM background EXEcution 29-7? -13 08.37.42.258000000 ?? ORACLE.EXE (M000) MMON_SLAVE KDILM background EXEcution 29-7? -13 08.37.43.258000000 ?? ORACLE.EXE (M000) MMON_SLAVE KDILM background EXEcution 29-7? -13 08.37.44.258000000 ?? ORACLE.EXE (M000) MMON_SLAVE KDILM background EXEcution 29-7? -13 08.38.42.386000000 ?? ORACLE.EXE (M001) MMON_SLAVE KDILM background EXEcution select distinct action from v$active_session_history where action like 'KDILM%' KDILM background CLeaNup KDILM background EXEcution SQL> execute set_window('MONDAY_WINDOW','CLOSE'); Set Maint. Window CLOSE ----------------------------- Window Name : MONDAY_WINDOW Enabled? : TRUE Active? : FALSE ----------------------------- PL/SQL ???????? SQL> drop table employee purge ; ????? ???? ????? spool ilm_usecase_1_cleanup.lst @ilm_demo_cleanup ; spool off

    Read the article

  • Is there a way to tell Drupal not to cache a specific page?

    - by TechplexEngineer
    I have a custom php page that processes a feed of images and makes albums out of it. However whenever i add pictures to my feed, the Drupal page doesn't change until I clear the caches. Is there a way to tell Drupal not to cache that specific page? Thanks, Blake Edit: Drupal v6.15 Not exactly sure what you mean oswald, team2648.com/media is hte page. I used the php interpreter module. Here is the php code: <?php //////// CODE by Pikori Web Designs - pikori.org /////////// //////// Please do not remove this title, /////////// //////// feel free to modify or copy this software /////////// $feedURL = 'http://picasaweb.google.com/data/feed/base/user/Techplex.Engineer?alt=rss&kind=album&hl=en_US'; $photoNodeNum = 4; $galleryTitle = 'Breakaway Pictures'; $year = '2011'; ?> <?php /////////////// DO NOT EDIT ANYTHING BELOW THIS LINE ////////////////// $album = $_GET['album']; if($album != ""){ //GENERATE PICTURES $feedURL= "http://".$album."&kind=photo&hl=en_US"; $feedURL = str_replace("entry","feed",$feedURL); $sxml = simplexml_load_file($feedURL); $column = 0; $pix_count = count($sxml->channel->item); //print '<h2>'.$sxml->channel->title.'</h2>'; print '<table cellspacing="0" cellpadding="0" style="font-size:10pt" width="100%"><tr>'; for($i = 0; $i < $pix_count; $i++) { print '<td align="center">'; $entry = $sxml->channel->item[$i]; $picture_url = $entry->enclosure['url']; $time = $entry->pubDate; $time_ln = strlen($time)-14; $time = substr($time,0,$time_ln); $description = $entry->description; $tn_beg = strpos($description, "src="); $tn_end = strpos($description, "alt="); $tn_length = $tn_end - $tn_beg; $tn = substr($description, $tn_beg, $tn_length); $tn_small = str_replace("s288","s128",$tn); $picture_url = $tn; $picture_beg = strpos($picture_url,"http:"); $picture_len = strlen($picture_url)-7; $picture_url = substr($tn, $picture_beg, $picture_len); $picture_url = str_replace("s288","s640",$picture_url); print '<a rel="lightbox[group]" href="'.$picture_url.'">'; print '<img '.$tn_small.' style="border:1px solid #02293a"><br>'; print '</a></td> '; if($column == 4){ print '</tr><tr>'; $column = 0;} else $column++; } print '</table>'; print '<br><center><a href="media">Return to album</a></center>'; } else { //GENERATE ALBUMS $sxml = simplexml_load_file($feedURL); $column = 0; $album_count = count($sxml->channel->item); //print '<h2>'.$galleryTitle.'</h2>'; print '<table cellspacing="0" cellpadding="0" style="font-size:10pt" width="100%"><tr>'; for($i = 0; $i < $album_count; $i++) { $entry = $sxml->channel->item[$i]; $time = $entry->pubDate; $time_ln = strlen($time)-14; $time = substr($time,0,$time_ln); $description = $entry->description; $tn_beg = strpos($description, "src="); $tn_end = strpos($description, "alt="); $tn_length = $tn_end - $tn_beg; $tn = substr($description, $tn_beg, $tn_length); $albumrss = $entry->guid; $albumrsscount = strlen($albumrss) - 7; $albumrss = substr($albumrss, 7, $albumrsscount); $search = strstr($time, $year); if($search != FALSE || $year == ''){ print '<td valign="top">'; print '<a href="/node/'.$photoNodeNum.'?album='.$albumrss.'">'; print '<center><img '.$tn.' style="border:3px double #cccccc"><br>'; print $entry->title.'<br>'.$time.'</center>'; print '</a><br></td> '; if($column == 3){ print '</tr><tr>'; $column = 0; } else { $column++; } } } print '</table>'; } ?>

    Read the article

  • How to bind grid in ASP.NET?

    - by Abid Ali
    I cant bind my Grid. I dont know what I am doing wrong, the grid appears empty when I run the program. here is my code :: protected void Page_Load(object sender, EventArgs e) { if (!IsPostBack) this.BindGrid(this.GridView1); } private void BindGrid(GridView grid) { SqlCommand cmd = new SqlCommand("Select * from Person", cn); SqlDataAdapter da = new SqlDataAdapter(cmd); DataTable dt = new DataTable(); da.Fill(dt); grid.DataSource = dt; grid.DataBind(); } <body> <form id="form1" runat="server"> <div style="margin-left: 240px"> <asp:GridView ID="GridView1" runat="server" CellPadding="4" ForeColor="#333333" GridLines="None" Width="856px" AutoGenerateColumns = "false" ShowFooter = "true" ShowHeader="true" BorderStyle="Groove" CaptionAlign="Top" HorizontalAlign="Center" onrowdatabound="GridView1_RowDataBound" > <RowStyle BackColor="#F7F6F3" ForeColor="#333333" /> <Columns> <asp:BoundField HeaderText="ID" /> <asp:BoundField HeaderText="First Name" /> <asp:BoundField HeaderText="Last Name" /> <asp:BoundField HeaderText="Home Phone #" /> <asp:BoundField HeaderText="Cell #" /> <asp:BoundField HeaderText="Email Address" /> <asp:BoundField HeaderText="NIC #" /> <asp:TemplateField HeaderText="Action"> <ItemTemplate> <asp:Button ID="Button1" runat="server" Text="Button" /> <asp:Button ID="Button2" runat="server" Text="Button" /> </ItemTemplate> </asp:TemplateField> </Columns> <FooterStyle BackColor="#5D7B9D" Font-Bold="True" ForeColor="White" /> <PagerStyle BackColor="#284775" ForeColor="White" HorizontalAlign="Center" /> <SelectedRowStyle BackColor="#E2DED6" Font-Bold="True" ForeColor="#333333" /> <HeaderStyle BackColor="#5D7B9D" Font-Bold="True" ForeColor="White" /> <EditRowStyle BackColor="#999999" /> <AlternatingRowStyle BackColor="White" ForeColor="#284775" /> </asp:GridView> </div> </form> </body>

    Read the article

  • Delaying NIS & NFS startup till after network interface is fully ready on Fedora 17

    - by obmarg
    I've recently set up a fedora 17 server for our network, and I've been having trouble getting the NIS service to work on startup. Here's some logs from the system: Aug 21 12:57:12 cairnwell ypbind-pre-setdomain[718]: Setting NIS domain: 'indigo-nis' (environment variable) Aug 21 12:57:13 cairnwell ypbind: Binding NIS service Aug 21 12:57:13 cairnwell rpc.statd[730]: Unable to prune capability 0 from bounding set: Operation not permitted Aug 21 12:57:13 cairnwell systemd[1]: nfs-lock.service: control process exited, code=exited status=1 Aug 21 12:57:13 cairnwell systemd[1]: Unit nfs-lock.service entered failed state. Aug 21 12:57:14 cairnwell setroubleshoot: SELinux is preventing /usr/sbin/rpc.statd from using the setpcap capability. For complete SELinux messages. run sealert -l 024bba8a-b0ef-43dc-b195-5c9a2d4c4d41 Aug 21 12:57:15 cairnwell kernel: [ 18.822282] bnx2 0000:02:00.0: em1: NIC Copper Link is Up, 1000 Mbps full duplex Aug 21 12:57:15 cairnwell kernel: [ 18.822925] ADDRCONF(NETDEV_CHANGE): em1: link becomes ready Aug 21 12:57:15 cairnwell NetworkManager[621]: <info> (em1): carrier now ON (device state 20) Aug 21 12:57:15 cairnwell NetworkManager[621]: <info> (em1): device state change: unavailable -> disconnected (reason 'carrier-changed') [20 30 40] Aug 21 12:57:15 cairnwell NetworkManager[621]: <info> Auto-activating connection 'System em1'. Aug 21 12:57:15 cairnwell NetworkManager[621]: <info> Activation (em1) starting connection 'System em1' Aug 21 12:57:15 cairnwell NetworkManager[621]: <info> (em1): device state change: disconnected -> prepare (reason 'none') [30 40 0] ....... Aug 21 12:57:19 cairnwell sendmail[790]: YPBINDPROC_DOMAIN: Domain not bound Aug 21 12:57:26 cairnwell sendmail[790]: YPBINDPROC_DOMAIN: Domain not bound Aug 21 12:57:31 cairnwell sendmail[790]: YPBINDPROC_DOMAIN: Domain not bound Aug 21 12:57:35 cairnwell sendmail[790]: YPBINDPROC_DOMAIN: Domain not bound Aug 21 12:58:00 cairnwell ypbind: Binding took 47 seconds Aug 21 12:58:00 cairnwell ypbind: NIS server for domain indigo-nis is not responding. Aug 21 12:58:01 cairnwell ypbind: Killing ypbind with PID 733. Aug 21 12:58:01 cairnwell ypbind-post-waitbind[734]: /usr/lib/ypbind/ypbind-post-waitbind: line 51: kill: SIGTERM: invalid signal specification Aug 21 12:58:01 cairnwell systemd[1]: ypbind.service: control process exited, code=exited status=1 Aug 21 12:58:01 cairnwell systemd[1]: Unit ypbind.service entered failed state. By the looks of these logs the ypbind service is starting up at 12:57:12 but the network interface isn't coming up till 12:57:15. My guess is that this is causing ypbind to time out when trying to connect. As a knock-on effect the NIS failure is causing problems with NFS which is no longer able to map UIDs properly. This problem doesn't seem to be fixed by actually starting ypbind etc. so I've had to set all my NFS shares to noauto. I have tried manually adding NETWORKDELAY and NETWORKWAIT in /etc/sysconfig/network and also running systemctl enable NetworkManager-wait-online.service as I've seen suggested in some places, but neither of these have had any effect. It is relatively easy to fix manually by restarting ypbind & mounting NFS shares after the network has started up, but it's less than ideal to have to do this every time the server has been rebooted. Does anyone know of an easy (and preferably hack-free) way of delaying the ypbind startup till after the network interface is fully ready?

    Read the article

  • Wireless AAA for a small, bandwidth-limited hotel.

    - by Anthony Hiscox
    We (the tech I work with and myself) live in a remote northern town where Internet access is somewhat of a luxury, and bandwidth is quite limited. Here, overage charges ranging from few hundreds, to few thousands of dollars a month, is not uncommon. I myself incur regular monthly charges just through my regular Internet usage at home (I am allowed 10G for $60CAD!) As part of my work, I have found myself involved with several hotels that are feeling this. I know that I can come up with something to solve this problem, but I am relatively new to system administration and I don't want my dreams to overcome reality. So, I pass these ideas on to you, those with much more experience than I, in hopes you will share some of your thoughts and concerns. This system must be cost effective, yes the charges are high here, but the trust in technology is the lowest I've ever seen. Must be capable of helping client reduce their usage (squid) Allow a limited (throughput and total usage) amount of free Internet, as this is often franchise policy. Allow a user to track their bandwidth usage Allow (optional) higher speed and/or usage for an additional charge. This fee can be obtained at the front desk on checkout and should not require the use of PayPal or Credit Card. Unfortunately some franchises have ridiculous policies that require the use of a third party remote service to authenticate guests to your network. This means WPA is out, and it also means that I do not auth before Internet usage, that will be their job. However, I do require the ABILITY to perform authentication for Internet access if a hotel does not have this policy. I will still have to track bandwidth (under a guest account by default) and provide the same limiting, however the guest often will require a complete 'unlimited' access, in terms of existence, not throughput. Provide firewalling capabilities for hotels that have nothing, Office, and Guest network segregation (some of these guys are running their office on the guest network, with no encryption, and a simple TOS to get on!) Prevent guests from connecting to other guests, however provide a means to allow this to happen. IE. Each guest connects to a page and allows the other guest, this writes a iptables rule (with python-netfilter) and allows two rooms to play a game, for instance. My thoughts on how to implement this. One decent box (we'll call it a router now) with a lot of ram, and 3 NIC's: Internet Office Guests (AP's + In Room Ethernet) Router Firewall Rules Guest can talk to router only, through which they are routed to where they need to go, including Internet services. Office can be used to bridge Office to Internet if an existing solution is not in place, otherwise, it simply works for a network accessible web (webmin+python-webmin?) interface. Router Software: OpenVZ provides virtualization for a few services I don't really trust. Squid, FreeRADIUS and Apache. The only service directly accessible to guests is Apache. Apache has mod_wsgi and django, because I can write quickly using django and my needs are low. It also potentially has the FreeRADIUS mod, but there seems to be some caveats with this. Firewall rules are handled on the router with iptables. Webmin (or a custom django app maybe) provides abstracted control over any features that the staff may need to access. Python, if you haven't guessed it's the language I feel most comfortable in, and I use it for almost everything. And finally, has this been done, is it a overly massive project not worth taking on for one guy, and/or is there some tools I'm missing that could be making my life easier? For the record, I am fairly good with Python, but not very familiar with many other languages (I can struggle through PHP, it's a cosmetic issue there). I am also an avid linux user, and comfortable with config files and command line. Thank you for your time, I look forward to reading your responses. Edit: My apologies if this is not a Q&A in the sense that some were expecting, I'm just looking for ideas and to make sure I'm not trying to do something that's been done. I'm looking at pfSense now as a possible start for what I need.

    Read the article

  • eth0 and eth1 both assigned same IP on boot

    - by Banjer
    I have a physical SLES 11 SP2 server on a Sun Fire x4140 that is giving me problems with networking upon reboot. The NICs are onboard. The networking appears successful during boot, but network services such as nfs fail hard. This is because eth0 and eth1 are both receiving the same configuration and are both ifup-ed. Once everything times out and I'm at the console, ifconfig shows that eth0 and eth1 are UP and running with the same IP. Attempting to ping anything in that subnet fails. Restarting the network service fixes the issue. eth0 is the correct NIC that should be configured as primary, per the MAC address. Question: Whats causing eth1 to be brought up with the same config as eth0?? I do not have a config script set up for eth1: banjer@harp:~> ls -la /etc/sysconfig/network/ total 104 drwxr-xr-x 6 root root 4096 Jun 11 12:21 . drwxr-xr-x 6 root root 4096 Apr 10 09:46 .. -rw-r--r-- 1 root root 13916 Apr 10 09:32 config -rw-r--r-- 1 root root 9952 Apr 10 09:36 dhcp -rw------- 1 root root 180 Jun 11 12:21 ifcfg-eth0 -rw------- 1 root root 180 Jun 11 12:21 ifcfg-eth3 -rw------- 1 root root 172 Feb 1 08:32 ifcfg-lo -rw-r--r-- 1 root root 29333 Feb 1 08:32 ifcfg.template drwxr-xr-x 2 root root 4096 Apr 10 09:32 if-down.d -rw-r--r-- 1 root root 239 Feb 1 08:32 ifroute-lo drwxr-xr-x 2 root root 4096 Apr 10 09:33 if-up.d drwx------ 2 root root 4096 May 5 2010 providers -rw-r--r-- 1 root root 25 Nov 16 2010 routes drwxr-xr-x 2 root root 4096 Apr 10 09:36 scripts On a side note, eth3 is also configured with an IP in a different subnet, but this has not posed any problems. FYI the kernel module being used is forcedeth. banjer@harp:~> sudo cat /etc/sysconfig/network/ifcfg-eth0 BOOTPROTO='static' BROADCAST='' ETHTOOL_OPTIONS='' IPADDR='172.21.64.25/20' MTU='' NAME='MCP55 Ethernet' NETWORK='' REMOTE_IPADDR='' STARTMODE='auto' USERCONTROL='no' ONBOOT="yes" Here's eth3 in case you need to see it: banjer@harp:~> sudo cat /etc/sysconfig/network/ifcfg-eth3 BOOTPROTO='static' BROADCAST='' ETHTOOL_OPTIONS='' IPADDR='172.11.200.4/24' MTU='' NAME='MCP55 Ethernet' NETWORK='' REMOTE_IPADDR='' STARTMODE='auto' USERCONTROL='no' ONBOOT="yes" Perhaps is something related to udev? 70-persistent-net-rules looks OK to me, but I may not understand it completely. banjer@harp:~> cat /etc/udev/rules.d/70-persistent-net.rules # This file was automatically generated by the /lib/udev/write_net_rules # program, run by the persistent-net-generator.rules rules file. # # You can modify it, as long as you keep each rule on a single # line, and change only the value of the NAME= key. # PCI device 0x10de:0x0373 (forcedeth) SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="00:18:4f:8d:85:4c", ATTR{dev_id}=="0x0", ATTR{type}=="1", KERNEL=="eth*", NAME="eth2" # PCI device 0x10de:0x0373 (forcedeth) SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="00:18:4f:8d:85:4a", ATTR{dev_id}=="0x0", ATTR{type}=="1", KERNEL=="eth*", NAME="eth0" # PCI device 0x10de:0x0373 (forcedeth) SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="00:18:4f:8d:85:4b", ATTR{dev_id}=="0x0", ATTR{type}=="1", KERNEL=="eth*", NAME="eth1" # PCI device 0x10de:0x0373 (forcedeth) SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="00:18:4f:8d:85:4d", ATTR{dev_id}=="0x0", ATTR{type}=="1", KERNEL=="eth*", NAME="eth3" # PCI device 0x1077:0x3032 (qla3xxx) SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="00:c1:dd:0e:34:6c", ATTR{dev_id}=="0x0", ATTR{type}=="1", KERNEL=="eth*", NAME="eth4" Any other thoughts on what would cause this?

    Read the article

  • iptable CLUSTERIP won't work

    - by Rad Akefirad
    We have some requirements which explained here. We tried to satisfy them without any success as described. Here is the brief information: Here are requirements: 1. High Availability 2. Load Balancing Current Configuration: Server #1: one static (real) IP for each 10.17.243.11 Server #2: one static (real) IP for each 10.17.243.12 Cluster (virtual and shared among all servers) IP: 10.17.243.15 I tried to use CLUSTERIP to have the cluster IP by the following: on the server #1 iptables -I INPUT -i eth0 -d 10.17.243.15 -j CLUSTERIP --new --hashmode sourceip --clustermac 01:00:5E:00:00:20 --total-nodes 2 --local-node 1 on the server #2 iptables -I INPUT -i eth0 -d 10.17.243.15 -j CLUSTERIP --new --hashmode sourceip --clustermac 01:00:5E:00:00:20 --total-nodes 2 --local-node 2 When we try to ping 10.17.243.15 there is no reply. And the web service (tomcat on port 8080) is not accessible either. However we managed to get the packets on both servers by using TCPDUMP. Some useful information: iptable roules (iptables -L -n -v): Chain INPUT (policy ACCEPT 21775 packets, 1470K bytes) pkts bytes target prot opt in out source destination 0 0 CLUSTERIP all -- eth0 * 0.0.0.0/0 10.17.243.15 CLUSTERIP hashmode=sourceip clustermac=01:00:5E:00:00:20 total_nodes=2 local_node=1 hash_init=0 Chain FORWARD (policy ACCEPT 0 packets, 0 bytes) pkts bytes target prot opt in out source destination Chain OUTPUT (policy ACCEPT 14078 packets, 44M bytes) pkts bytes target prot opt in out source destination Log messages: ... kernel: [ 7.329017] e1000e: eth3 NIC Link is Up 100 Mbps Full Duplex, Flow Control: None ... kernel: [ 7.329133] e1000e 0000:05:00.0: eth3: 10/100 speed: disabling TSO ... kernel: [ 7.329567] ADDRCONF(NETDEV_CHANGE): eth3: link becomes ready ... kernel: [ 71.333285] ip_tables: (C) 2000-2006 Netfilter Core Team ... kernel: [ 71.341804] nf_conntrack version 0.5.0 (16384 buckets, 65536 max) ... kernel: [ 71.343168] ipt_CLUSTERIP: ClusterIP Version 0.8 loaded successfully ... kernel: [ 108.456043] device eth0 entered promiscuous mode ... kernel: [ 112.678859] device eth0 left promiscuous mode ... kernel: [ 117.916050] device eth0 entered promiscuous mode ... kernel: [ 140.168848] device eth0 left promiscuous mode TCPDUMP while pinging: tcpdump: listening on eth0, link-type EN10MB (Ethernet), capture size 65535 bytes 12:11:55.335528 IP (tos 0x0, ttl 64, id 0, offset 0, flags [DF], proto ICMP (1), length 84) 10.17.243.1 > 10.17.243.15: ICMP echo request, id 16162, seq 2390, length 64 12:11:56.335778 IP (tos 0x0, ttl 64, id 0, offset 0, flags [DF], proto ICMP (1), length 84) 10.17.243.1 > 10.17.243.15: ICMP echo request, id 16162, seq 2391, length 64 12:11:57.336010 IP (tos 0x0, ttl 64, id 0, offset 0, flags [DF], proto ICMP (1), length 84) 10.17.243.1 > 10.17.243.15: ICMP echo request, id 16162, seq 2392, length 64 12:11:58.336287 IP (tos 0x0, ttl 64, id 0, offset 0, flags [DF], proto ICMP (1), length 84) 10.17.243.1 > 10.17.243.15: ICMP echo request, id 16162, seq 2393, length 64 And there is no ping reply as I said. Does anyone know which part I missed? Thanks in advance.

    Read the article

  • how to make bridge networking with KVM work in Fedora19

    - by netllama
    I'm attempting to get several virtual machines setup on a Fedora-19 host system, with the traditional bridge network devices (br0, br1, etc). I've done this many times before with older versions of Fedora (16, 14, etc), and it just works. However, for reasons that I cannot figure out, the bridge doesn't seem to be working in Fedora19. While I can successfully connect to the outside world (local network + internet) from inside a VM, nothing can communicate with the VM from outside (local network). I'm referring to something as trivial as pinging. From inside the VM, I can ping anything successfully (0% packet loss). However, from outside the VM (on the host, or any other system on the same network), I see 100% packet loss when pinging the IP address of the VM. My first question is simply, does anyone else have this working successfully in F19? And if so, what steps did you need to follow? I'm not using NetworkManager at all, its all the network service. There are no firewalls involved anywhere (iptables & firewall services are currently disabled). Here's the current host configuration: # brctl show bridge name bridge id STP enabled interfaces br0 8000.38eaa792efe5 no em2 vnet1 br1 8000.38eaa792efe6 no em3 br2 8000.38eaa792efe7 no em4 vnet0 virbr0 8000.525400db3ebf yes virbr0-nic # more /etc/sysconfig/network-scripts/ifcfg-em2 TYPE=Ethernet BRIDGE="br0" NAME=em2 DEVICE="em2" UUID=aeaa839e-c89c-4d6e-9daa-79b6a1b919bd ONBOOT=yes HWADDR=38:EA:A7:92:EF:E5 NM_CONTROLLED="no" # more /etc/sysconfig/network-scripts/ifcfg-br0 TYPE=Bridge NM_CONTROLLED="no" BOOTPROTO=dhcp NAME=br0 DEVICE="br0" ONBOOT=yes # ifconfig em2 ;ifconfig br0 em2: flags=4163<UP,BROADCAST,RUNNING,MULTICAST> mtu 1500 inet6 fe80::3aea:a7ff:fe92:efe5 prefixlen 64 scopeid 0x20<link> ether 38:ea:a7:92:ef:e5 txqueuelen 1000 (Ethernet) RX packets 100093 bytes 52354831 (49.9 MiB) RX errors 0 dropped 0 overruns 0 frame 0 TX packets 25321 bytes 15791341 (15.0 MiB) TX errors 0 dropped 0 overruns 0 carrier 0 collisions 0 device memory 0xf7d00000-f7e00000 br0: flags=4163<UP,BROADCAST,RUNNING,MULTICAST> mtu 1500 inet 10.31.99.226 netmask 255.255.252.0 broadcast 10.31.99.255 inet6 fe80::3aea:a7ff:fe92:efe5 prefixlen 64 scopeid 0x20<link> ether 38:ea:a7:92:ef:e5 txqueuelen 0 (Ethernet) RX packets 19619 bytes 1963328 (1.8 MiB) RX errors 0 dropped 0 overruns 0 frame 0 TX packets 11 bytes 1074 (1.0 KiB) TX errors 0 dropped 0 overruns 0 carrier 0 collisions 0 Relevant section from /etc/libvirt/qemu/foo.xml (one of the VMs with this problem): <interface type='bridge'> <mac address='52:54:00:26:22:9d'/> <source bridge='br0'/> <model type='virtio'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x03' function='0x0'/> </interface> # ps -ef | grep qemu qemu 1491 1 82 13:25 ? 00:42:09 /usr/bin/qemu-system-x86_64 -machine accel=kvm -name cuda-linux64-build5 -S -machine pc-0.13,accel=kvm,usb=off -cpu SandyBridge,+pdpe1gb,+osxsave,+dca,+pcid,+pdcm,+xtpr,+tm2,+est,+smx,+vmx,+ds_cpl,+monitor,+dtes64,+pbe,+tm,+ht,+ss,+acpi,+ds,+vme -m 16384 -smp 6,sockets=6,cores=1,threads=1 -uuid 6e930234-bdfd-044d-2787-22d4bbbe30b1 -no-user-config -nodefaults -chardev socket,id=charmonitor,path=/var/lib/libvirt/qemu/cuda-linux64-build5.monitor,server,nowait -mon chardev=charmonitor,id=monitor,mode=control -rtc base=localtime -no-shutdown -device piix3-usb-uhci,id=usb,bus=pci.0,addr=0x1.0x2 -drive file=/var/lib/libvirt/images/cuda-linux64-build5.img,if=none,id=drive-virtio-disk0,format=raw,cache=writeback -device virtio-blk-pci,scsi=off,bus=pci.0,addr=0x4,drive=drive-virtio-disk0,id=virtio-disk0,bootindex=1 -netdev tap,fd=25,id=hostnet0,vhost=on,vhostfd=26 -device virtio-net-pci,netdev=hostnet0,id=net0,mac=52:54:00:26:22:9d,bus=pci.0,addr=0x3 -chardev pty,id=charserial0 -device isa-serial,chardev=charserial0,id=serial0 -vnc 127.0.0.1:1 -vga cirrus -device virtio-balloon-pci,id=balloon0,bus=pci.0,addr=0x5 I can provide additional information, if requested. thanks!

    Read the article

  • Improving TCP performance over a gigabit network with lots of connections and high traffic of small packets

    - by MinimeDJ
    I’m trying to improve my TCP throughput over a “gigabit network with lots of connections and high traffic of small packets”. My server OS is Ubuntu 11.10 Server 64bit. There are about 50.000 (and growing) clients connected to my server through TCP Sockets (all on the same port). 95% of of my packets have size of 1-150 bytes (TCP header and payload). The rest 5% vary from 150 up to 4096+ bytes. With the config below my server can handle traffic up to 30 Mbps (full duplex). Can you please advice best practice to tune OS for my needs? My /etc/sysctl.cong looks like this: kernel.pid_max = 1000000 net.ipv4.ip_local_port_range = 2500 65000 fs.file-max = 1000000 # net.core.netdev_max_backlog=3000 net.ipv4.tcp_sack=0 # net.core.rmem_max = 16777216 net.core.wmem_max = 16777216 net.core.somaxconn = 2048 # net.ipv4.tcp_rmem = 4096 87380 16777216 net.ipv4.tcp_wmem = 4096 65536 16777216 # net.ipv4.tcp_synack_retries = 2 net.ipv4.tcp_syncookies = 1 net.ipv4.tcp_mem = 50576 64768 98152 # net.core.wmem_default = 65536 net.core.rmem_default = 65536 net.ipv4.tcp_window_scaling=1 # net.ipv4.tcp_mem= 98304 131072 196608 # net.ipv4.tcp_timestamps = 0 net.ipv4.tcp_rfc1337 = 1 net.ipv4.ip_forward = 0 net.ipv4.tcp_congestion_control=cubic net.ipv4.tcp_tw_recycle = 0 net.ipv4.tcp_tw_reuse = 0 # net.ipv4.tcp_orphan_retries = 1 net.ipv4.tcp_fin_timeout = 25 net.ipv4.tcp_max_orphans = 8192 Here are my limits: $ ulimit -a core file size (blocks, -c) 0 data seg size (kbytes, -d) unlimited scheduling priority (-e) 0 file size (blocks, -f) unlimited pending signals (-i) 193045 max locked memory (kbytes, -l) 64 max memory size (kbytes, -m) unlimited open files (-n) 1000000 pipe size (512 bytes, -p) 8 POSIX message queues (bytes, -q) 819200 real-time priority (-r) 0 stack size (kbytes, -s) 8192 cpu time (seconds, -t) unlimited max user processes (-u) 1000000 [ADDED] My NICs are the following: $ dmesg | grep Broad [ 2.473081] Broadcom NetXtreme II 5771x 10Gigabit Ethernet Driver bnx2x 1.62.12-0 (2011/03/20) [ 2.477808] bnx2x 0000:02:00.0: eth0: Broadcom NetXtreme II BCM57711E XGb (A0) PCI-E x4 5GHz (Gen2) found at mem fb000000, IRQ 28, node addr d8:d3:85:bd:23:08 [ 2.482556] bnx2x 0000:02:00.1: eth1: Broadcom NetXtreme II BCM57711E XGb (A0) PCI-E x4 5GHz (Gen2) found at mem fa000000, IRQ 40, node addr d8:d3:85:bd:23:0c [ADDED 2] ethtool -k eth0 Offload parameters for eth0: rx-checksumming: on tx-checksumming: on scatter-gather: on tcp-segmentation-offload: on udp-fragmentation-offload: off generic-segmentation-offload: on generic-receive-offload: on large-receive-offload: on rx-vlan-offload: on tx-vlan-offload: on ntuple-filters: off receive-hashing: off [ADDED 3] sudo ethtool -S eth0|grep -vw 0 NIC statistics: [1]: rx_bytes: 17521104292 [1]: rx_ucast_packets: 118326392 [1]: tx_bytes: 35351475694 [1]: tx_ucast_packets: 191723897 [2]: rx_bytes: 16569945203 [2]: rx_ucast_packets: 114055437 [2]: tx_bytes: 36748975961 [2]: tx_ucast_packets: 194800859 [3]: rx_bytes: 16222309010 [3]: rx_ucast_packets: 109397802 [3]: tx_bytes: 36034786682 [3]: tx_ucast_packets: 198238209 [4]: rx_bytes: 14884911384 [4]: rx_ucast_packets: 104081414 [4]: rx_discards: 5828 [4]: rx_csum_offload_errors: 1 [4]: tx_bytes: 35663361789 [4]: tx_ucast_packets: 194024824 [5]: rx_bytes: 16465075461 [5]: rx_ucast_packets: 110637200 [5]: tx_bytes: 43720432434 [5]: tx_ucast_packets: 202041894 [6]: rx_bytes: 16788706505 [6]: rx_ucast_packets: 113123182 [6]: tx_bytes: 38443961940 [6]: tx_ucast_packets: 202415075 [7]: rx_bytes: 16287423304 [7]: rx_ucast_packets: 110369475 [7]: rx_csum_offload_errors: 1 [7]: tx_bytes: 35104168638 [7]: tx_ucast_packets: 184905201 [8]: rx_bytes: 12689721791 [8]: rx_ucast_packets: 87616037 [8]: rx_discards: 2638 [8]: tx_bytes: 36133395431 [8]: tx_ucast_packets: 196547264 [9]: rx_bytes: 15007548011 [9]: rx_ucast_packets: 98183525 [9]: rx_csum_offload_errors: 1 [9]: tx_bytes: 34871314517 [9]: tx_ucast_packets: 188532637 [9]: tx_mcast_packets: 12 [10]: rx_bytes: 12112044826 [10]: rx_ucast_packets: 84335465 [10]: rx_discards: 2494 [10]: tx_bytes: 36562151913 [10]: tx_ucast_packets: 195658548 [11]: rx_bytes: 12873153712 [11]: rx_ucast_packets: 89305791 [11]: rx_discards: 2990 [11]: tx_bytes: 36348541675 [11]: tx_ucast_packets: 194155226 [12]: rx_bytes: 12768100958 [12]: rx_ucast_packets: 89350917 [12]: rx_discards: 2667 [12]: tx_bytes: 35730240389 [12]: tx_ucast_packets: 192254480 [13]: rx_bytes: 14533227468 [13]: rx_ucast_packets: 98139795 [13]: tx_bytes: 35954232494 [13]: tx_ucast_packets: 194573612 [13]: tx_bcast_packets: 2 [14]: rx_bytes: 13258647069 [14]: rx_ucast_packets: 92856762 [14]: rx_discards: 3509 [14]: rx_csum_offload_errors: 1 [14]: tx_bytes: 35663586641 [14]: tx_ucast_packets: 189661305 rx_bytes: 226125043936 rx_ucast_packets: 1536428109 rx_bcast_packets: 351 rx_discards: 20126 rx_filtered_packets: 8694 rx_csum_offload_errors: 11 tx_bytes: 548442367057 tx_ucast_packets: 2915571846 tx_mcast_packets: 12 tx_bcast_packets: 2 tx_64_byte_packets: 35417154 tx_65_to_127_byte_packets: 2006984660 tx_128_to_255_byte_packets: 373733514 tx_256_to_511_byte_packets: 378121090 tx_512_to_1023_byte_packets: 77643490 tx_1024_to_1522_byte_packets: 43669214 tx_pause_frames: 228 Some info about SACK: When to turn TCP SACK off?

    Read the article

  • Vagrant (Virtualbox) host-only multiple node networking issue

    - by Lorin Hochstein
    I'm trying to use a multi-VM vagrant environment as a testbed for deploying OpenStack, and I've run into a networking problem with trying to communicate from one VM, to a VM-inside-of-a-VM. I have two Vagrant nodes, a cloud controller node and a compute node. I'm using host-only networking. My Vagrantfile looks like this: Vagrant::Config.run do |config| config.vm.box = "precise64" config.vm.define :controller do |controller_config| controller_config.vm.network :hostonly, "192.168.206.130" # eth1 controller_config.vm.network :hostonly, "192.168.100.130" # eth2 controller_config.vm.host_name = "controller" end config.vm.define :compute1 do |compute1_config| compute1_config.vm.network :hostonly, "192.168.206.131" # eth1 compute1_config.vm.network :hostonly, "192.168.100.131" # eth2 compute1_config.vm.host_name = "compute1" compute1_config.vm.customize ["modifyvm", :id, "--memory", 1024] end end When I try to start up a (QEMU-based) VM, it boots successfully on compute1, and its virtual nic (vnet0) is connected via a bridge, br100: root@compute1:~# brctl show 100 bridge name bridge id STP enabled interfaces br100 8000.08002798c6ef no eth2 vnet0 When the QEMU VM makes a request to the DHCP server (dnsmasq) running on controller, I can see the request reaches the controller because of the output on the syslog on the controller: Aug 6 02:34:56 precise64 dnsmasq-dhcp[12042]: DHCPDISCOVER(br100) fa:16:3e:07:98:11 Aug 6 02:34:56 precise64 dnsmasq-dhcp[12042]: DHCPOFFER(br100) 192.168.100.2 fa:16:3e:07:98:11 However, the DHCPOFFER never makes it back to the VM running on compute1. If I watch the requests using tcpdump on the vboxnet3 interface on my host machine that runs Vagrant (Mac OS X), I can see both the requests and the replies $ sudo tcpdump -i vboxnet3 -n port 67 or port 68 tcpdump: WARNING: vboxnet3: That device doesn't support promiscuous mode (BIOCPROMISC: Operation not supported on socket) tcpdump: verbose output suppressed, use -v or -vv for full protocol decode listening on vboxnet3, link-type EN10MB (Ethernet), capture size 65535 bytes 22:51:20.694040 IP 0.0.0.0.68 > 255.255.255.255.67: BOOTP/DHCP, Request from fa:16:3e:07:98:11, length 280 22:51:20.694057 IP 0.0.0.0.68 > 255.255.255.255.67: BOOTP/DHCP, Request from fa:16:3e:07:98:11, length 280 22:51:20.696047 IP 192.168.100.1.67 > 192.168.100.2.68: BOOTP/DHCP, Reply, length 311 22:51:23.700845 IP 0.0.0.0.68 > 255.255.255.255.67: BOOTP/DHCP, Request from fa:16:3e:07:98:11, length 280 22:51:23.700876 IP 0.0.0.0.68 > 255.255.255.255.67: BOOTP/DHCP, Request from fa:16:3e:07:98:11, length 280 22:51:23.701591 IP 192.168.100.1.67 > 192.168.100.2.68: BOOTP/DHCP, Reply, length 311 22:51:26.705978 IP 0.0.0.0.68 > 255.255.255.255.67: BOOTP/DHCP, Request from fa:16:3e:07:98:11, length 280 22:51:26.705995 IP 0.0.0.0.68 > 255.255.255.255.67: BOOTP/DHCP, Request from fa:16:3e:07:98:11, length 280 22:51:26.706527 IP 192.168.100.1.67 > 192.168.100.2.68: BOOTP/DHCP, Reply, length 311 But, if I tcpdump on eth2 on compute, I only see the requests, not the replies: root@compute1:~# tcpdump -i eth2 -n port 67 or port 68 tcpdump: WARNING: eth2: no IPv4 address assigned tcpdump: verbose output suppressed, use -v or -vv for full protocol decode listening on eth2, link-type EN10MB (Ethernet), capture size 65535 bytes 02:51:20.240672 IP 0.0.0.0.68 > 255.255.255.255.67: BOOTP/DHCP, Request from fa:16:3e:07:98:11, length 280 02:51:23.249758 IP 0.0.0.0.68 > 255.255.255.255.67: BOOTP/DHCP, Request from fa:16:3e:07:98:11, length 280 02:51:26.258281 IP 0.0.0.0.68 > 255.255.255.255.67: BOOTP/DHCP, Request from fa:16:3e:07:98:11, length 280 At this point, I'm stuck. I'm not sure why the DHCP replies aren't making it to the compute node. Perhaps it has something to do with the configuration of the VirtualBox virtual switch/router? Note that eth2 interfaces on both nodes have been set to promiscuous mode.

    Read the article

  • CentOS 6.2 Bridge Setup for KVM

    - by Gaia
    I'm trying to set up bridged networking with KVM on CentOS 6.2 to no avail. There are plenty of docs and tutorials about it, but they all seem to conflict or don't provide info specific enough to my situation. I just don't get it. I access the host via public IP "xxx.xxx.128.58". All other available IPs (/29) should be bridged and made available to the only KVM guest (running a public facing LAMP stack) that will be setup on this machine. The amazingly unhelpful NOC people assigned the extra IPs to eth1. Is this correct? Should br0 bridge to eth0 or eth1? How do I set this up? Here is the relevant info: eth0 Link encap:Ethernet HWaddr 00:25:90:68:FE:BC inet6 addr: fe80::225:90ff:fe68:febc/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:763 errors:0 dropped:0 overruns:0 frame:0 TX packets:8 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:550811 (537.9 KiB) TX bytes:648 (648.0 b) Memory:fb980000-fba00000 eth1 Link encap:Ethernet HWaddr 00:25:90:68:FE:BD inet addr:xxx.xxx.128.58 Bcast:xxx.xxx.128.63 Mask:255.255.255.248 inet6 addr: fe80::225:90ff:fe68:febd/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:1806 errors:0 dropped:0 overruns:0 frame:0 TX packets:1505 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:133166 (130.0 KiB) TX bytes:106070 (103.5 KiB) Memory:fb900000-fb980000 eth1:0 Link encap:Ethernet HWaddr 00:25:90:68:FE:BD inet addr:xxx.xxx.128.59 Bcast:xxx.xxx.128.63 Mask:255.255.255.248 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 Memory:fb900000-fb980000 eth1:1 Link encap:Ethernet HWaddr 00:25:90:68:FE:BD inet addr:xxx.xxx.128.60 Bcast:xxx.xxx.128.63 Mask:255.255.255.248 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 Memory:fb900000-fb980000 eth1:2 Link encap:Ethernet HWaddr 00:25:90:68:FE:BD inet addr:xxx.xxx.128.61 Bcast:xxx.xxx.128.63 Mask:255.255.255.248 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 Memory:fb900000-fb980000 eth1:3 Link encap:Ethernet HWaddr 00:25:90:68:FE:BD inet addr:xxx.xxx.128.62 Bcast:xxx.xxx.128.63 Mask:255.255.255.248 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 Memory:fb900000-fb980000 lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:0 (0.0 b) TX bytes:0 (0.0 b) virbr0 Link encap:Ethernet HWaddr 52:54:00:62:55:68 inet addr:192.168.122.1 Bcast:192.168.122.255 Mask:255.255.255.0 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:0 (0.0 b) TX bytes:0 (0.0 b) > cat /etc/sysconfig/network NETWORKING=yes HOSTNAME=XXXX.domain.com > brctl show bridge name bridge id STP enabled interfaces br0 8000.00259068febc no eth0 virbr0 8000.525400625568 yes virbr0-nic > ls -fl | grep ifcfg -rw-r--r-- 1 root root 198 Jun 7 10:58 ifcfg-eth0 -rw-r--r--. 1 root root 254 Oct 7 2011 ifcfg-lo -rw-r--r-- 1 root root 77 Jun 6 18:51 ifcfg-eth1-range0 -rw-r--r-- 1 root root 168 Jun 6 18:50 ifcfg-eth1 > cat ifcfg-eth0 DEVICE="eth0" BOOTPROTO="static" BRIDGE="br0" HWADDR="00:25:90:68:FE:BC" IPV6INIT="yes" MTU="1500" NM_CONTROLLED="yes" ONBOOT="yes" TYPE="Ethernet" IPADDR="yyy.yyy.216.131" NETMASK="255.255.255.128" > cat ifcfg-eth1 DEVICE="eth1" HWADDR="00:25:90:68:FE:BD" NM_CONTROLLED="yes" ONBOOT="yes" BOOTPROTO="static" IPADDR="xxx.xxx.128.58" NETMASK="255.255.255.248" GATEWAY="xxx.xxx.128.57" > cat ifcfg-eth1-range0 IPADDR_START="xxx.xxx.128.59" IPADDR_END="xxx.xxx.128.62" CLONENUM_START="0" Kernel IP routing table Destination Gateway Genmask Flags Metric Ref Use Iface xxx.xxx.128.56 * 255.255.255.248 U 0 0 0 eth1 192.168.122.0 * 255.255.255.0 U 0 0 0 virbr0 link-local * 255.255.0.0 U 1003 0 0 eth1 default xxx.xxx.128.57 0.0.0.0 UG 0 0 0 eth1

    Read the article

  • Multiple Homed Windows 2008 Server / Windows 7 Client

    - by Daniel Scott
    I have a small Windows 2008 network, with some Windows 7 clients. The clients are both laptops with docking stations and I would like them to communicate with the Windows 2008 server (for filesharing) through the wired network whilst they're docked. Internet connectivity for all machines (clients and server) is via a Wireless LAN, so the wireless adapter in the Windows 7 clients stays active while they're docked. When the laptops are un-docked, it would be nice to still be able to contact the windows 2008 server for print sharing (and slower file sharing) - hence the server also being on the wireless LAN. The windows 2008 server is running Active Directory, DHCP and DNS. It controls DHCP leases on the wired network and holds the DNS records for "myserver.mycompany.local", which is what the filesharing clients connect to. Ideally I'd like the DNS records to return the wired IP first so that this is the address that the laptops will attempt initially - but there doesn't seem to be a way to do that? At present the server's IP on the wireless LAN comes out of an nslookup above the wired Lan IP. The multi-homing works perfectly - but in the wrong order! Switch on the wireless lan and ping myserver and it goes to the wireless IP. Disable the wireless on the client and do the same ping again and after a couple of seconds it starts pinging the wired address. Does anyone have any suggestions on how to make this work in a predictable order? - or even if it can work. Alternative 1? If it can't work, then would this work: Remove the wireless adapter from the server, put a wireless router/bridge on the wired network (set up to route to/from the wireless LAN's subnet), then configure the clients with two routes to the (now) single IP of the server with metrics favouring direct communication over the wired LAN first? Alternative 2? Should I instead single-home the laptops so all of their connectivity is via the wired-LAN while they're docked? (and route via the windows 2008 server - or a dedicated wireless bridge/router)? My concern here is that I'd like undocking to be seamless - and if the clients are in the middle of downloading something from the internet I wouldn't want whatever they're doing interupted as they switch IP addresses onto the Wireless network. Perhaps this isn't the case and I'm concerned over nothing? Any thoughts? :) UPDATE I seem to have cracked it (at least DNS entries come out in the order I hope for - and pinging the server with various combinations of wired, wireless and both interfaces enabled uses the IP I want) ... I set the binding order of the NICs on the Server (which is acting as Domain Controller, DHCP and DNS server) so that the Wired NIC is before the Wireless adapter. (Start -- type "Network Interfaces" -- Select "View Network Connections" -- Press Alt to show classic dropdown menus -- Advanced -- Advanced Settings) Now, an nslookup (from the client) of the server's hostname returns the Wired IP first, followed by the Wireless IP. The wired IP now seems to be used whenever it's contactable. Incidentally, the metrics on the wired and wireless routes (on the client) also favour the wired LAN (based on Windows' automatically assigned metrics) - but this was always the case, even when I was having trouble getting the wired IP to be "favoured". I'm not entirely sure if this is coincidence - or if a DNS server running on Windows, handing back IP addresses for itself does actually take the binding order of it's own network interfaces into account? It would be interesting to hear from someone who can confirm or deny that (or confirm that the binding order on the server plays a role for some other reason?)

    Read the article

  • XFS disk becomes unavailable after a while

    - by Guard
    Ubuntu 12.04 (but the same was on 11.10 before upgrading) WD MyBook, 2TB, no RAID (or RAID0, not completely sure, anyway no mirroring, both 1TB disks are in use, mounted as a single device). Formatted to XFS, normally used for big movie files. Connected to Firewire 800. At some point the LED started going up and down as when constantly reading/writing. The device gives access error. When unplugged (cable, then holding the power button for a while, then unplugging the power) and re-connected becomes available. xfs_check with no results. xfs_repair did something, but looks like didn't fix any error. Then after a massive read (checking 1.5GB torrent file for integrity) becomes unavailable again. Any ideas what's wrong? Drives? Cables? Motherboard? OS? UPD: not sure how relevant this is, but here are dmesg output [14380.632816] SGI XFS with ACLs, security attributes, realtime, large block/inode numbers, no debug enabled [14380.633356] SGI XFS Quota Management subsystem [14421.812220] firewire_core: phy config: card 0, new root=ffc1, gap_count=5 [14441.890596] firewire_core: phy config: card 0, new root=ffc1, gap_count=5 [14441.896858] firewire_core: phy config: card 0, new root=ffc1, gap_count=5 [14453.895347] firewire_core: created device fw1: GUID 0090a99500a35518, S400, 9 config ROM retries [14453.904818] scsi6 : SBP-2 IEEE-1394 [14453.905014] scsi7 : SBP-2 IEEE-1394 [14454.139993] firewire_sbp2: fw1.0: logged in to LUN 0000 (0 retries) [14454.158769] scsi 6:0:0:0: Direct-Access WD My Book 1015 PQ: 0 ANSI: 4 [14454.159251] sd 6:0:0:0: Attached scsi generic sg3 type 0 [14454.162391] firewire_sbp2: fw1.1: logged in to LUN 0001 (0 retries) [14454.167453] sd 6:0:0:0: [sdc] 3907017568 512-byte logical blocks: (2.00 TB/1.81 TiB) [14454.178822] sd 6:0:0:0: [sdc] Write Protect is off [14454.178826] sd 6:0:0:0: [sdc] Mode Sense: 10 00 00 00 [14454.186830] scsi 7:0:0:1: Enclosure WD My Book Device 1015 PQ: 0 ANSI: 4 [14454.186995] scsi 7:0:0:1: Attached scsi generic sg4 type 13 [14454.190078] sd 6:0:0:0: [sdc] Cache data unavailable [14454.190087] sd 6:0:0:0: [sdc] Assuming drive cache: write through [14454.202176] sd 6:0:0:0: [sdc] Cache data unavailable [14454.202185] sd 6:0:0:0: [sdc] Assuming drive cache: write through [14454.239940] sdc: [mac] sdc1 sdc2 sdc3 sdc4 [14454.271262] sd 6:0:0:0: [sdc] Cache data unavailable [14454.271270] sd 6:0:0:0: [sdc] Assuming drive cache: write through [14454.271354] sd 6:0:0:0: [sdc] Attached SCSI disk [14454.272149] ses 7:0:0:1: Attached Enclosure device [14606.090024] XFS (sdc3): Mounting Filesystem [14612.048343] XFS (sdc3): Starting recovery (logdev: internal) [14620.697636] XFS (sdc3): Ending recovery (logdev: internal) [14748.120957] e1000e: eth0 NIC Link is Up 100 Mbps Full Duplex, Flow Control: Rx/Tx [14748.120963] e1000e 0000:00:19.0: eth0: 10/100 speed: disabling TSO [14752.568382] uhci_hcd 0000:00:1a.0: PCI INT A disabled [14752.568579] uhci_hcd 0000:00:1a.1: PCI INT B disabled [14752.568738] ehci_hcd 0000:00:1a.7: PCI INT C disabled [14752.568779] ehci_hcd 0000:00:1a.7: PME# enabled [14752.584526] uhci_hcd 0000:00:1d.1: PCI INT B disabled [14752.584689] uhci_hcd 0000:00:1d.2: PCI INT C disabled [14752.680079] ehci_hcd 0000:00:1a.7: BAR 0: set to [mem 0xe4641000-0xe46413ff] (PCI address [0xe4641000-0xe46413ff]) [14752.680104] ehci_hcd 0000:00:1a.7: restoring config space at offset 0xf (was 0x300, writing 0x30b) [14752.680136] ehci_hcd 0000:00:1a.7: restoring config space at offset 0x1 (was 0x2900000, writing 0x2900002) [14752.680170] ehci_hcd 0000:00:1a.7: PME# disabled [14752.680182] ehci_hcd 0000:00:1a.7: PCI INT C -> GSI 18 (level, low) -> IRQ 18 [14752.680190] ehci_hcd 0000:00:1a.7: setting latency timer to 64 [14752.710334] uhci_hcd 0000:00:1a.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [14752.710342] uhci_hcd 0000:00:1a.0: setting latency timer to 64 [14752.749186] uhci_hcd 0000:00:1a.1: PCI INT B -> GSI 17 (level, low) -> IRQ 17 [14752.749194] uhci_hcd 0000:00:1a.1: setting latency timer to 64 [14752.790231] uhci_hcd 0000:00:1d.1: PCI INT B -> GSI 22 (level, low) -> IRQ 22 [14752.790239] uhci_hcd 0000:00:1d.1: setting latency timer to 64 [14752.829170] uhci_hcd 0000:00:1d.2: PCI INT C -> GSI 18 (level, low) -> IRQ 18 [14752.829178] uhci_hcd 0000:00:1d.2: setting latency timer to 64

    Read the article

  • iptables - quick safety eval & limit max conns over time

    - by Peter Hanneman
    Working on locking down a *nix server box with some fancy iptable(v1.4.4) rules. I'm approaching the matter with a "paranoid, everyone's out to get me" style, not necessarily because I expect the box to be a hacker magnet but rather just for the sake of learning iptables and *nix security more throughly. Everything is well commented - so if anyone sees something I missed please let me know! The *nat table's "--to-ports" point to the only ports with actively listening services. (aside from pings) Layer 2 apps listen exclusively on chmod'ed sockets bridged by one of the layer 1 daemons. Layers 3+ inherit from layer 2 in a similar fashion. The two lines giving me grief are commented out at the very bottom of the *filter rules. The first line runs fine but it's all or nothing. :) Many thanks, Peter H. *nat #Flush previous rules, chains and counters for the 'nat' table -F -X -Z #Redirect traffic to alternate internal ports -I PREROUTING --src 0/0 -p tcp --dport 80 -j REDIRECT --to-ports 8080 -I PREROUTING --src 0/0 -p tcp --dport 443 -j REDIRECT --to-ports 8443 -I PREROUTING --src 0/0 -p udp --dport 53 -j REDIRECT --to-ports 8053 -I PREROUTING --src 0/0 -p tcp --dport 9022 -j REDIRECT --to-ports 8022 COMMIT *filter #Flush previous settings, chains and counters for the 'filter' table -F -X -Z #Set default behavior for all connections and protocols -P INPUT DROP -P OUTPUT DROP -A FORWARD -j DROP #Only accept loopback traffic originating from the local NIC -A INPUT -i lo -j ACCEPT -A INPUT ! -i lo -d 127.0.0.0/8 -j DROP #Accept all outgoing non-fragmented traffic having a valid state -A OUTPUT ! -f -m state --state NEW,RELATED,ESTABLISHED -j ACCEPT #Drop fragmented incoming packets (Not always malicious - acceptable for use now) -A INPUT -f -j DROP #Allow ping requests rate limited to one per second (burst ensures reliable results for high latency connections) -A INPUT -p icmp --icmp-type 8 -m limit --limit 1/sec --limit-burst 2 -j ACCEPT #Declaration of custom chains -N INSPECT_TCP_FLAGS -N INSPECT_STATE -N INSPECT #Drop incoming tcp connections with invalid tcp-flags -A INSPECT_TCP_FLAGS -p tcp --tcp-flags ALL ALL -j DROP -A INSPECT_TCP_FLAGS -p tcp --tcp-flags ALL NONE -j DROP -A INSPECT_TCP_FLAGS -p tcp --tcp-flags ACK,FIN FIN -j DROP -A INSPECT_TCP_FLAGS -p tcp --tcp-flags ACK,PSH PSH -j DROP -A INSPECT_TCP_FLAGS -p tcp --tcp-flags ACK,URG URG -j DROP -A INSPECT_TCP_FLAGS -p tcp --tcp-flags SYN,FIN SYN,FIN -j DROP -A INSPECT_TCP_FLAGS -p tcp --tcp-flags ALL FIN,PSH,URG -j DROP -A INSPECT_TCP_FLAGS -p tcp --tcp-flags FIN,RST FIN,RST -j DROP -A INSPECT_TCP_FLAGS -p tcp --tcp-flags SYN,RST SYN,RST -j DROP -A INSPECT_TCP_FLAGS -p tcp --tcp-flags ALL SYN,FIN,PSH,URG -j DROP -A INSPECT_TCP_FLAGS -p tcp --tcp-flags ALL SYN,RST,ACK,FIN,URG -j DROP #Accept incoming traffic having either an established or related state -A INSPECT_STATE -m state --state ESTABLISHED,RELATED -j ACCEPT #Drop new incoming tcp connections if they aren't SYN packets -A INSPECT_STATE -m state --state NEW -p tcp ! --syn -j DROP #Drop incoming traffic with invalid states -A INSPECT_STATE -m state --state INVALID -j DROP #INSPECT chain definition -A INSPECT -p tcp -j INSPECT_TCP_FLAGS -A INSPECT -j INSPECT_STATE #Route incoming traffic through the INSPECT chain -A INPUT -j INSPECT #Accept redirected HTTP traffic via HA reverse proxy -A INPUT -p tcp --dport 8080 -j ACCEPT #Accept redirected HTTPS traffic via STUNNEL SSH gateway (As well as tunneled HTTPS traffic destine for other services) -A INPUT -p tcp --dport 8443 -j ACCEPT #Accept redirected DNS traffic for NSD authoritative nameserver -A INPUT -p udp --dport 8053 -j ACCEPT #Accept redirected SSH traffic for OpenSSH server #Temp solution: -A INPUT -p tcp --dport 8022 -j ACCEPT #Ideal solution: #Limit new ssh connections to max 10 per 10 minutes while allowing an "unlimited" (or better reasonably limited?) number of established connections. #-A INPUT -p tcp --dport 8022 --state NEW,ESTABLISHED -m recent --set -j ACCEPT #-A INPUT -p tcp --dport 8022 --state NEW -m recent --update --seconds 600 --hitcount 11 -j DROP COMMIT *mangle #Flush previous rules, chains and counters in the 'mangle' table -F -X -Z COMMIT

    Read the article

  • Where is my VMware-ws FreeNAS CIFS(ZFS) bottle-neck?

    - by maka
    Background: I'm building a quiet HTPC + NAS that is also supposed to be used for general computer usage. I'm so far generally happy with things, it was just that I was expecting a little better IO performance. I have no clue if my expectations are unreal. The NAS is there as a general purpose file storage and as a media server for XBMC and other devices. ZFS is a requirement. Question: Where is my bottle-neck, and is there anything I can do config wise, to improve my performance? I'm thinking VM-disk settings could be something but I really have no idea where to go since I'm neither experienced with FreeNAS nor VMware-WS. Tests: When I'm on the host OS and copy files (from the SSD) to the CIFS share, I get around 30 Mbytes/sec read and write. When I'm on my laptop laptop, wired to the network, I get about the same specs. The test I've done are with a 16 GB ISO, and with about 200 MB of RARs and I've tried avoiding the RAM-cache by reading different files than the ones I'm writing ( 10 GB). It feels like having less CPU cores is a lot more efficient, since the resource manager in Windows reports less CPU-usage. With 4 cores in VMware, CPU usage was 50-80%, with 1 core it was 25-60%. EDIT: HD ActiveTime was quite high on SSD so I moved the page file, disabled hibernate and enabled Win DiskCache both on SSD and RAID. This resulted in no real performance difference for one file, but if i transferred 2 files the total speed went up to 50 Mbytes/s vs ~40. The ActiveTime avg also went down a lot (to ~20%) but has now higher bursts. DiskIO is on ~ 30-35 Mbytes/s avgs, with ~100Mb bursts. Network is on 200-250Mbits/s with ~45 active TCP connections. Hardware Asus F2A85-M Pro A10-5700 16GB DDR3 1600 OCZ Vertex 2 128GB SSD 2x Generic 1tb 7200 RPM drives as RAID0 (in win7) Intel Gigabit Desktop CT Software Host OS: Win7 (SSD) VMware Worksation 9 (SSD) FreeNAS 8.3 VM (20GB VDisk on SSD) CPU: I've tried 1, 2 and 4 cores. Virtualisation engine, Preferred mode: Automatic 10,24Gb ram 50Gb SCSI VDisk on the RAID0, VDisk is formatted as ZFS and exposed through CIFS through FreeNAS. NIC Bridge, Replicate physical network state Below are two typical process print-outs while I'm transfering one file to the CIFS share. last pid: 2707; load averages: 0.60, 0.43, 0.24 up 0+00:07:05 00:34:26 32 processes: 2 running, 30 sleeping Mem: 101M Active, 53M Inact, 1620M Wired, 2188K Cache, 149M Buf, 8117M Free Swap: 4096M Total, 4096M Free PID USERNAME THR PRI NICE SIZE RES STATE TIME WCPU COMMAND 2640 root 1 102 0 50164K 10364K RUN 0:25 25.98% smbd 1897 root 6 44 0 168M 74808K uwait 0:02 0.00% python last pid: 2746; load averages: 0.93, 0.60, 0.33 up 0+00:08:53 00:36:14 33 processes: 2 running, 31 sleeping Mem: 101M Active, 53M Inact, 4722M Wired, 2188K Cache, 152M Buf, 5015M Free Swap: 4096M Total, 4096M Free PID USERNAME THR PRI NICE SIZE RES STATE TIME WCPU COMMAND 2640 root 1 76 0 50164K 10364K RUN 0:52 16.99% smbd 1897 root 6 44 0 168M 74816K uwait 0:02 0.00% python I'm sorry if my question isn't phrased right, I'm really bad at these kind of things, and it is the first time I post here at SU. I also appreciate any other suggestions to something, I could have missed.

    Read the article

  • suddenly can't connect to router

    - by Khoi
    I was just downloading some stuff in ubuntu and snap, the connection cut and I can't even connect to my router. And the router, it still works fine, my laptop can connect wirelessly to it as usual. But my main computer (which connects to it directly through cable) can't even ping it. Here is my ipconfig: Windows IP Configuration Host Name . . . . . . . . . . . . : vento Primary Dns Suffix . . . . . . . : Node Type . . . . . . . . . . . . : Unknown IP Routing Enabled. . . . . . . . : No WINS Proxy Enabled. . . . . . . . : No Ethernet adapter Local Area Connection: Media State . . . . . . . . . . . : Media disconnected Description . . . . . . . . . . . : Realtek RTL8169/8110 Family Gigabit Ethernet NIC Physical Address. . . . . . . . . : 00-19-DB-4E-6C-56 Ethernet adapter {15B1F740-2F35-4FE4-9FEE-4052AFBAD096}: Media State . . . . . . . . . . . : Media disconnected Description . . . . . . . . . . . : Anchorfree HSS Adapter - Packet Sche duler Miniport Physical Address. . . . . . . . . : 00-FF-15-B1-F7-40

    Read the article

  • What's new in Solaris 11.1?

    - by Karoly Vegh
    Solaris 11.1 is released. This is the first release update since Solaris 11 11/11, the versioning has been changed from MM/YY style to 11.1 highlighting that this is Solaris 11 Update 1.  Solaris 11 itself has been great. What's new in Solaris 11.1? Allow me to pick some new features from the What's New PDF that can be found in the official Oracle Solaris 11.1 Documentation. The updates are very numerous, I really can't include all.  I. New AI Automated Installer RBAC profiles have been introduced to enable delegation of installation tasks. II. The interactive installer now supports installing the OS to iSCSI targets. III. ASR (Auto Service Request) and OCM (Oracle Configuration Manager) have been enabled by default to proactively provide support information and create service requests to speed up support processes. This is optional and can be disabled but helps a lot in supportcases. For further information, see: http://oracle.com/goto/solarisautoreg IV. The new command svcbundle helps you to create SMF manifests without having to struggle with XML editing. (btw, do you know the interactive editprop subcommand in svccfg? The listprop/setprop subcommands are great for scripting and automating, but for an interactive property editing session try, for example, this: svccfg -s svc:/application/pkg/system-repository:default editprop )  V. pfedit: Ever wondered how to delegate editing permissions to certain files? It is well known "sudo /usr/bin/vi /etc/hosts" is not the right way, for sudo elevates the complete vi process to admin levels, and the user can "break" out of the session as root with simply starting a shell from that vi. Now, the new pfedit command provides a solution exactly to this challenge - an auditable, secure, per-user configurable editing possibility. See the pfedit man page for examples.   VI. rsyslog, the popular logging daemon (filters, SSL, formattable output, SQL collect...) has been included in Solaris 11.1 as an alternative to syslog.  VII: Zones: Solaris Zones - as a major Solaris differentiator - got lots of love in terms of new features: ZOSS - Zones on Shared Storage: Placing your zones to shared storage (FC, iSCSI) has never been this easy - via zonecfg.  parallell updates - with S11's bootenvironments updating zones was no problem and meant no downtime anyway, but still, now you can update them parallelly, a way faster update action if you are running a large number of zones. This is like parallell patching in Solaris 10, but with all the IPS/ZFS/S11 goodness.  per-zone fstype statistics: Running zones on a shared filesystems complicate the I/O debugging, since ZFS collects all the random writes and delivers them sequentially to boost performance. Now, over kstat you can find out which zone's I/O has an impact on the other ones, see the examples in the documentation: http://docs.oracle.com/cd/E26502_01/html/E29024/gmheh.html#scrolltoc Zones got RDSv3 protocol support for InfiniBand, and IPoIB support with Crossbow's anet (automatic vnic creation) feature.  NUMA I/O support for Zones: customers can now determine the NUMA I/O topology of the system from within zones.  VIII: Security got a lot of attention too:  Automated security/audit reporting, with builtin reporting templates e.g. for PCI (payment card industry) audits.  PAM is now configureable on a per-user basis instead of system wide, allowing different authentication requirements for different users  SSH in Solaris 11.1 now supports running in FIPS 140-2 mode, that is, in a U.S. government security accredited fashion.  SHA512/224 and SHA512/256 cryptographic hash functions are implemented in a FIPS-compliant way - and on a T4 implemented in silicon! That is, goverment-approved cryptography at HW-speed.  Generally, Solaris is currently under evaluation to be both FIPS and Common Criteria certified.  IX. Networking, as one of the core strengths of Solaris 11, has been extended with:  Data Center Bridging (DCB) - not only setups where network and storage share the same fabric (FCoE, anyone?) can have Quality-of-Service requirements. DCB enables peers to distinguish traffic based on priorities. Your NICs have to support DCB, see the documentation, and additional information on Wikipedia. DataLink MultiPathing, DLMP, enables link aggregation to span across multiple switches, even between those of different vendors. But there are essential differences to the good old bandwidth-aggregating LACP, see the documentation: http://docs.oracle.com/cd/E26502_01/html/E28993/gmdlu.html#scrolltoc VNIC live migration is now supported from one physical NIC to another on-the-fly  X. Data management:  FedFS, (Federated FileSystem) is new, it relies on Solaris 11's NFS referring mechanism to join separate shares of different NFS servers into a single filesystem namespace. The referring system has been there since S11 11/11, in Solaris 11.1 FedFS uses a LDAP - as the one global nameservice to bind them all.  The iSCSI initiator now uses the T4 CPU's HW-implemented CRC32 algorithm - thus improving iSCSI throughput while reducing CPU utilization on a T4 Storage locking improvements are now RAC aware, speeding up throughput with better locking-communication between nodes up to 20%!  XI: Kernel performance optimizations: The new Virtual Memory subsystem ("VM2") scales now to 100+ TB Memory ranges.  The memory predictor monitors large memory page usage, and adjust memory page sizes to applications' needs OSM, the Optimized Shared Memory allows Oracle DBs' SGA to be resized online XII: The Power Aware Dispatcher in now by default enabled, reducing power consumption of idle CPUs. Also, the LDoms' Power Management policies and the poweradm settings in Solaris 11 OS will cooperate. XIII: x86 boot: upgrade to the (Grand Unified Bootloader) GRUB2. Because grub2 differs in the configuration syntactically from grub1, one shall not edit the new grub configuration (grub.cfg) but use the new bootadm features to update it. GRUB2 adds UEFI support and also support for disks over 2TB. XIV: Improved viewing of per-CPU statistics of mpstat. This one might seem of less importance at first, but nowadays having better sorting/filtering possibilities on a periodically updated mpstat output of 256+ vCPUs can be a blessing. XV: Support for Solaris Cluster 4.1: The What's New document doesn't actually mention this one, since OSC 4.1 has not been released at the time 11.1 was. But since then it is available, and it requires Solaris 11.1. And it's only a "pkg update" away. ...aand I seriously need to stop here. There's a lot I missed, Edge Virtual Bridging, lofi tuning, ZFS sharing and crypto enhancements, USB3.0, pulseaudio, trusted extensions updates, etc - but if I mention all those then I effectively copy the What's New document. Which I recommend reading now anyway, it is a great extract of the 300+ new projects and RFE-followups in S11.1. And this blogpost is a summary of that extract.  For closing words, allow me to come back to Request For Enhancements, RFEs. Any customer can request features. Open up a Support Request, explain that this is an RFE, describe the feature you/your company desires to have in S11 implemented. The more SRs are collected for an RFE, the more chance it's got to get implemented. Feel free to provide feedback about the product, as well as about the Solaris 11.1 Documentation using the "Feedback" button there. Both the Solaris engineers and the documentation writers are eager to hear your input.Feel free to comment about this post too. Except that it's too long ;)  wbr,charlie

    Read the article

  • OpenIndiana (illumos): vmxnet3 interface lost on reboot

    - by protomouse
    I want my VMware vmxnet3 interface to be brought up with DHCP on boot. I can manually configure the NIC with: # ifconfig vmxnet3s0 plumb # ipadm create-addr -T dhcp vmxnet3s0/v4dhcp But after creating /etc/dhcp.vmxnet3s0 and rebooting, the interface is down and the logs show: Aug 13 09:34:15 neumann vmxnet3s: [ID 654879 kern.notice] vmxnet3s:0: getcapab(0x200000) -> no Aug 13 09:34:15 neumann vmxnet3s: [ID 715698 kern.notice] vmxnet3s:0: stop() Aug 13 09:34:17 neumann vmxnet3s: [ID 654879 kern.notice] vmxnet3s:0: getcapab(0x200000) -> no Aug 13 09:34:17 neumann vmxnet3s: [ID 920500 kern.notice] vmxnet3s:0: start() Aug 13 09:34:17 neumann vmxnet3s: [ID 778983 kern.notice] vmxnet3s:0: getprop(TxRingSize) -> 256 Aug 13 09:34:17 neumann vmxnet3s: [ID 778983 kern.notice] vmxnet3s:0: getprop(RxRingSize) -> 256 Aug 13 09:34:17 neumann vmxnet3s: [ID 778983 kern.notice] vmxnet3s:0: getprop(RxBufPoolLimit) -> 512 Aug 13 09:34:17 neumann nwamd[491]: [ID 605049 daemon.error] 1: nwamd_set_unset_link_properties: dladm_set_linkprop failed: operation not supported Aug 13 09:34:17 neumann vmxnet3s: [ID 654879 kern.notice] vmxnet3s:0: getcapab(0x20000) -> no Aug 13 09:34:17 neumann nwamd[491]: [ID 751932 daemon.error] 1: nwamd_down_interface: ipadm_delete_addr failed on vmxnet3s0: Object not found Aug 13 09:34:17 neumann nwamd[491]: [ID 819019 daemon.error] 1: nwamd_plumb_unplumb_interface: plumb IPv4 failed for vmxnet3s0: Operation not supported on disabled object Aug 13 09:34:17 neumann nwamd[491]: [ID 160156 daemon.error] 1: nwamd_plumb_unplumb_interface: plumb IPv6 failed for vmxnet3s0: Operation not supported on disabled object Aug 13 09:34:17 neumann nwamd[491]: [ID 771489 daemon.error] 1: add_ip_address: ipadm_create_addr failed on vmxnet3s0: Operation not supported on disabled object Aug 13 09:34:17 neumann nwamd[491]: [ID 405346 daemon.error] 9: start_dhcp: ipadm_create_addr failed for vmxnet3s0: Operation not supported on disabled object I then tried disabling network/physical:nwam in favour of network/physical:default. This works, the interface is brought up but physical:default fails and my network services (e.g. NFS) refuse to start. # ifconfig -a lo0: flags=2001000849<UP,LOOPBACK,RUNNING,MULTICAST,IPv4,VIRTUAL> mtu 8232 index 1 inet 127.0.0.1 netmask ff000000 vmxnet3s0: flags=1004843<UP,BROADCAST,RUNNING,MULTICAST,DHCP,IPv4> mtu 9000 index 2 inet 192.168.178.248 netmask ffffff00 broadcast 192.168.178.255 vmxnet3s0:1: flags=1004842<BROADCAST,RUNNING,MULTICAST,DHCP,IPv4> mtu 9000 index 2 inet 192.168.178.248 netmask ffffff00 broadcast 192.168.178.255 vmxnet3s0:2: flags=1004842<BROADCAST,RUNNING,MULTICAST,DHCP,IPv4> mtu 9000 index 2 inet 192.168.178.248 netmask ffffff00 broadcast 192.168.178.255 vmxnet3s0:3: flags=1004842<BROADCAST,RUNNING,MULTICAST,DHCP,IPv4> mtu 9000 index 2 inet 192.168.178.248 netmask ffffff00 broadcast 192.168.178.255 vmxnet3s0:4: flags=1004842<BROADCAST,RUNNING,MULTICAST,DHCP,IPv4> mtu 9000 index 2 inet 192.168.178.248 netmask ffffff00 broadcast 192.168.178.255 vmxnet3s0:5: flags=1004842<BROADCAST,RUNNING,MULTICAST,DHCP,IPv4> mtu 9000 index 2 inet 192.168.178.248 netmask ffffff00 broadcast 192.168.178.255 vmxnet3s0:6: flags=1004842<BROADCAST,RUNNING,MULTICAST,DHCP,IPv4> mtu 9000 index 2 inet 192.168.178.248 netmask ffffff00 broadcast 192.168.178.255 vmxnet3s0:7: flags=1004842<BROADCAST,RUNNING,MULTICAST,DHCP,IPv4> mtu 9000 index 2 inet 192.168.178.248 netmask ffffff00 broadcast 192.168.178.255 vmxnet3s0:8: flags=1004842<BROADCAST,RUNNING,MULTICAST,DHCP,IPv4> mtu 9000 index 2 inet 192.168.178.248 netmask ffffff00 broadcast 192.168.178.255 lo0: flags=2002000849<UP,LOOPBACK,RUNNING,MULTICAST,IPv6,VIRTUAL> mtu 8252 index 1 inet6 ::1/128 vmxnet3s0: flags=20002000840<RUNNING,MULTICAST,IPv6> mtu 9000 index 2 inet6 ::/0 # cat /var/svc/log/network-physical\:default.log [ Aug 16 09:46:39 Enabled. ] [ Aug 16 09:46:41 Executing start method ("/lib/svc/method/net-physical"). ] [ Aug 16 09:46:41 Timeout override by svc.startd. Using infinite timeout. ] starting DHCP on primary interface vmxnet3s0 ifconfig: vmxnet3s0: DHCP is already running [ Aug 16 09:46:43 Method "start" exited with status 96. ] NFS server not running: # svcs -xv network/nfs/server svc:/network/nfs/server:default (NFS server) State: offline since August 16, 2012 09:46:40 AM UTC Reason: Service svc:/network/physical:default is not running because a method failed. See: http://illumos.org/msg/SMF-8000-GE Path: svc:/network/nfs/server:default svc:/milestone/network:default svc:/network/physical:default Reason: Service svc:/network/physical:nwam is disabled. See: http://illumos.org/msg/SMF-8000-GE Path: svc:/network/nfs/server:default svc:/milestone/network:default svc:/network/physical:nwam Reason: Service svc:/network/nfs/nlockmgr:default is disabled. See: http://illumos.org/msg/SMF-8000-GE Path: svc:/network/nfs/server:default svc:/network/nfs/nlockmgr:default See: man -M /usr/share/man -s 1M nfsd Impact: This service is not running. I'm new to the world of Solaris, so any help solving would be much appreciated. Thanks!

    Read the article

  • KVM/Libvirt bridged/routed networking not working on newer guest kernels

    - by SharkWipf
    I have a dedicated server running Debian 6, with Libvirt (0.9.11.3) and Qemu-KVM (qemu-kvm-1.0+dfsg-11, Debian). I am having a problem getting bridged/routed networking to work in KVM guests with newer kernels (2.6.38). NATted networking works fine though. Older kernels work perfectly fine as well. The host kernel is at version 3.2.0-2-amd64, the problem was also there on an older host kernel. The contents of the host's /etc/network/interfaces (ip removed): # Loopback device: auto lo iface lo inet loopback # bridge auto br0 iface br0 inet static address 176.9.xx.xx broadcast 176.9.xx.xx netmask 255.255.255.224 gateway 176.9.xx.xx pointopoint 176.9.xx.xx bridge_ports eth0 bridge_stp off bridge_maxwait 0 bridge_fd 0 up route add -host 176.9.xx.xx dev br0 # VM IP post-up mii-tool -F 100baseTx-FD br0 # default route to access subnet up route add -net 176.9.xx.xx netmask 255.255.255.224 gw 176.9.xx.xx br0 The output of ifconfig -a on the host: br0 Link encap:Ethernet HWaddr 54:04:a6:8a:66:13 inet addr:176.9.xx.xx Bcast:176.9.xx.xx Mask:255.255.255.224 inet6 addr: fe80::5604:a6ff:fe8a:6613/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:20216729 errors:0 dropped:0 overruns:0 frame:0 TX packets:19962220 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:14144528601 (13.1 GiB) TX bytes:7990702656 (7.4 GiB) eth0 Link encap:Ethernet HWaddr 54:04:a6:8a:66:13 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:26991788 errors:0 dropped:12066 overruns:0 frame:0 TX packets:19737261 errors:270082 dropped:0 overruns:0 carrier:270082 collisions:1686317 txqueuelen:1000 RX bytes:15459970915 (14.3 GiB) TX bytes:6661808415 (6.2 GiB) Interrupt:17 Memory:fe500000-fe520000 lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:6240133 errors:0 dropped:0 overruns:0 frame:0 TX packets:6240133 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:6081956230 (5.6 GiB) TX bytes:6081956230 (5.6 GiB) virbr0 Link encap:Ethernet HWaddr 52:54:00:79:e4:5a inet addr:192.168.100.1 Bcast:192.168.100.255 Mask:255.255.255.0 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:225016 errors:0 dropped:0 overruns:0 frame:0 TX packets:412958 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:16284276 (15.5 MiB) TX bytes:687827984 (655.9 MiB) virbr0-nic Link encap:Ethernet HWaddr 52:54:00:79:e4:5a BROADCAST MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:500 RX bytes:0 (0.0 B) TX bytes:0 (0.0 B) vnet0 Link encap:Ethernet HWaddr fe:54:00:93:4e:68 inet6 addr: fe80::fc54:ff:fe93:4e68/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:607670 errors:0 dropped:0 overruns:0 frame:0 TX packets:5932089 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:500 RX bytes:83574773 (79.7 MiB) TX bytes:1092482370 (1.0 GiB) vnet1 Link encap:Ethernet HWaddr fe:54:00:ed:6a:43 inet6 addr: fe80::fc54:ff:feed:6a43/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:922132 errors:0 dropped:0 overruns:0 frame:0 TX packets:6342375 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:500 RX bytes:251091242 (239.4 MiB) TX bytes:1629079567 (1.5 GiB) vnet2 Link encap:Ethernet HWaddr fe:54:00:0d:cb:3d inet6 addr: fe80::fc54:ff:fe0d:cb3d/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:9461 errors:0 dropped:0 overruns:0 frame:0 TX packets:665189 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:500 RX bytes:4990275 (4.7 MiB) TX bytes:49229647 (46.9 MiB) vnet3 Link encap:Ethernet HWaddr fe:54:cd:83:eb:aa inet6 addr: fe80::fc54:cdff:fe83:ebaa/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:1649 errors:0 dropped:0 overruns:0 frame:0 TX packets:12177 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:500 RX bytes:77233 (75.4 KiB) TX bytes:2127934 (2.0 MiB) The guest's /etc/network/interfaces, in this case running Ubuntu 12.04 (ip removed): # This file describes the network interfaces available on your system # and how to activate them. For more information, see interfaces(5). # The loopback network interface auto lo iface lo inet loopback auto eth0 iface eth0 inet static address 176.9.xx.xx netmask 255.255.255.248 gateway 176.9.xx.xx # Host IP pointopoint 176.9.xx.xx # Host IP dns-nameservers 8.8.8.8 8.8.4.4 The output of ifconfig -a on the guest: eth0 Link encap:Ethernet HWaddr 52:54:cd:83:eb:aa inet addr:176.9.xx.xx Bcast:0.0.0.0 Mask:255.255.255.255 inet6 addr: fe80::5054:cdff:fe83:ebaa/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:14190 errors:0 dropped:0 overruns:0 frame:0 TX packets:1768 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:2614642 (2.6 MB) TX bytes:82700 (82.7 KB) lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:954 errors:0 dropped:0 overruns:0 frame:0 TX packets:954 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:176679 (176.6 KB) TX bytes:176679 (176.6 KB) Output of ping -c4 on the guest: PING google.nl (173.194.35.151) 56(84) bytes of data. 64 bytes from muc03s01-in-f23.1e100.net (173.194.35.151): icmp_req=1 ttl=55 time=14.7 ms From static.174.82.xx.xx.clients.your-server.de (176.9.xx.xx): icmp_seq=2 Redirect Host(New nexthop: static.161.82.9.176.clients.your-server.de (176.9.82.161)) 64 bytes from muc03s01-in-f23.1e100.net (173.194.35.151): icmp_req=2 ttl=55 time=15.1 ms From static.198.170.9.176.clients.your-server.de (176.9.170.198) icmp_seq=3 Destination Host Unreachable From static.198.170.9.176.clients.your-server.de (176.9.170.198) icmp_seq=4 Destination Host Unreachable --- google.nl ping statistics --- 4 packets transmitted, 2 received, +2 errors, 50% packet loss, time 3002ms rtt min/avg/max/mdev = 14.797/14.983/15.170/0.223 ms, pipe 2 The static.174.82.xx.xx.clients.your-server.de (176.9.xx.xx) is the host's IP. I have encountered this problem with every guest OS I've tried, that being Fedora, Ubuntu (server/desktop) and Debian with an upgraded kernel. I've also tried compiling the guest kernel myself, to no avail. I have no problem with recompiling a kernel, though the host cannot afford any downtime. Any ideas on this problem are very welcome. EDIT: I can ping the host from inside the guest.

    Read the article

  • What is Causing this IIS 7 Web Service Sporadic Connectivity Error?

    - by dpalau
    On sporadic occasions we receive the following error when attempting to call an .asmx web service from a .Net client application: "The underlying connection was closed: A connection that was expected to be kept alive was closed by the server. Unable to read data from the transport connection: An existing connection was forcibly closed by the remote host." By sporadic I mean that it might occur zero, once every few days, or a half-dozen times a day for some users. It will never occur for the first web service call of a user. And the subsequent (usually the same) call will always work immediately after the failure. The failures happen across a variety of methods in the service and usually happens between 15-20 seconds (according to the log) from the time of the request. Looking in the IIS site log for the particular call will show one or the other of the following windows error codes: 121: The semaphore timeout period has elapsed. 1236: The network connection was aborted by the local system. Some additional environment details: Running on internal network web farm consisting of two servers running IIS7 on Windows Server 2008 OS. These problems did not occur when running in an older IIS6 web farm of three servers running on Windows Server 2003 (and we use a single IIS6/2003 instance for our development and staging environments with no issues). EDIT: Also, all of these server instances are VMWare virtual machines, not sure if that is a surprise anymore or not. The web service is a .Net 2.0/3.5 compiled .asmx web service that has its own application pool (.Net 2.0, integrated pipeline). Only has Windows Authentication enabled. We have another web service on the farm that uses the same physical path as the primary service, the only difference being that Basic Authentication is enabled. This is used for a portion of our ERP system. Have tried using the same and different application pool - no effect on the error. This site isn't hit as often as the primary site and has never had an error. As mentioned, the error will only happen when called from the .Net client - not from other applications. The client application is always creating a new web service object for each request and setting the service credentials to System.Net.CredentialCache.DefaultCredentials. The application is either deployed locally to a client or run in a Citrix server session. Those users running in Citrix doesn't seem to experience the issue, only locally deployed clients. The Citrix servers and the web farm are located in the same physical location and are located in the same IP range (10.67.xx.xx). Locally deployed clients experiencing the error are located elsewhere (10.105.xx.xx, 10.31.xx.xx). I've checked the OS logs to see if I can see any problems but nothing really sticks out. EDIT: Actually, I myself just ran into the error a little bit ago. I decided to check out the logs again and saw that there was a Security log entry of "Audit Failure" at the 'same' time (IIS log entry at 1:39:59, event log entry at 1:39:50). Not sure if this is a coincidence or not, I'll have to check out the logs of previous errors. I'm probably grasping for straws but the details: Log Name: Security Source: Microsoft-Windows-Security-Auditing Date: 7/8/2009 1:39:50 PM Event ID: 5159 Task Category: Filtering Platform Connection Level: Information Keywords: Audit Failure User: N/A Computer: is071019.<**.net Description: The Windows Filtering Platform has blocked a bind to a local port. Application Information: Process ID: 1260 Application Name: \device\harddiskvolume1\windows\system32\svchost.exe Network Information: Source Address: 0.0.0.0 Source Port: 54802 Protocol: 17 Filter Information: Filter Run-Time ID: 0 Layer Name: Resource Assignment Layer Run-Time ID: 36 I've also tried to use Failed Request Tracing in IIS7 but the service call never actually gets to where FRT can capture it (even though the failure is logged in the web service log). The network infrastructure group said they checked out the DNS and any NIC settings are correct so there is no 'flapping'. Everything pans out. I'm not sure that they checked out any domain controller servers though to see if that could be an issue. Any ideas? Or any other debugging strategies to get to the bottom of this? I'm just the developer in charge of the software and don't really have the knowledge on what to investigate from the networking side of things - although it does sound like a networking issue to me based on what is happening. Thanks in advance for any help.

    Read the article

< Previous Page | 36 37 38 39 40 41  | Next Page >