Search Results

Search found 11093 results on 444 pages for 'issues'.

Page 412/444 | < Previous Page | 408 409 410 411 412 413 414 415 416 417 418 419  | Next Page >

  • opennms postgres connection slow

    - by krisdigitx
    i am running the opennms application server on a physical server and the database on an ESXi VM. Recently the opennms webconsole has been very slow to load as such i deleted most of the events from the database table, now both servers have no load at all, and the psql connection from the application server to the database server is also very fast, but somehow opennms webconsole is still slow. this is the strace from the opennms process id: 18629 futex(0x2aaac77d8a84, FUTEX_WAIT_PRIVATE, 453, NULL <unfinished ...> 3015 futex(0x2aaabc4a2ee4, FUTEX_WAIT_PRIVATE, 323, NULL <unfinished ...> 10863 futex(0x2aaabbebaa94, FUTEX_WAIT_PRIVATE, 395, NULL <unfinished ...> 25260 <... futex resumed> ) = -1 ETIMEDOUT (Connection timed out) 10859 <... futex resumed> ) = -1 ETIMEDOUT (Connection timed out) 10982 <... futex resumed> ) = -1 ETIMEDOUT (Connection timed out) 3011 <... futex resumed> ) = -1 ETIMEDOUT (Connection timed out) 25260 futex(0x2aaae098fc28, FUTEX_WAKE_PRIVATE, 1 <unfinished ...> 10982 futex(0x2aaac0eaf928, FUTEX_WAKE_PRIVATE, 1 <unfinished ...> 3011 futex(0x2aaab0cb1728, FUTEX_WAKE_PRIVATE, 1 <unfinished ...> 10859 futex(0x2aaac062c328, FUTEX_WAKE_PRIVATE, 1 <unfinished ...> 25260 <... futex resumed> ) = 0 10982 <... futex resumed> ) = 0 3011 <... futex resumed> ) = 0 10859 <... futex resumed> ) = 0 25260 futex(0x2aaabc38b6b4, FUTEX_WAIT_PRIVATE, 443, NULL <unfinished ...> 10982 futex(0x2aaabc5d7b94, FUTEX_WAIT_PRIVATE, 99, NULL <unfinished ...> 3011 futex(0x2aaac7c55334, FUTEX_WAIT_PRIVATE, 183, NULL <unfinished ...> 10859 futex(0x2aaabbb8c9d4, FUTEX_WAIT_PRIVATE, 347, NULL <unfinished ...> 10846 <... futex resumed> ) = -1 ETIMEDOUT (Connection timed out) 10846 futex(0x2aaae9022428, FUTEX_WAKE_PRIVATE, 1) = 0 10846 futex(0x2aaabe0030b4, FUTEX_WAIT_PRIVATE, 251, NULL <unfinished ...> 20281 <... futex resumed> ) = -1 ETIMEDOUT (Connection timed out) 14100 <... futex resumed> ) = -1 ETIMEDOUT (Connection timed out) 2925 <... futex resumed> ) = -1 ETIMEDOUT (Connection timed out) 10843 <... futex resumed> ) = -1 ETIMEDOUT (Connection timed out) 20281 futex(0x2aaac7e93628, FUTEX_WAKE_PRIVATE, 1 <unfinished ...> 14100 futex(0x2aaac04e8c28, FUTEX_WAKE_PRIVATE, 1 <unfinished ...> 2925 futex(0x2aaaec085528, FUTEX_WAKE_PRIVATE, 1 <unfinished ...> 10843 futex(0x2aaab20b0528, FUTEX_WAKE_PRIVATE, 1 <unfinished ...> and shows lots of connection timeout??? i think its the connection between the java application and database which is causing issues. any ideas how to troubleshoot this???

    Read the article

  • All PHP sites stopped working on IIS7, internal server error 500

    - by TimothyP
    I installed multiple drupal 7 sites using the Web Platform Installer on Windows Server 2008. Until know they worked without any problems, but recently internal server error 500 started to show up (once every so many requests), now it happens for all requests to any of the php sites. There's not much detail to go on, and nothing changed between the time when it was working and now (well nothing I know of anyway) The log file is flooded with messages such as [09-Aug-2011 09:08:04] PHP Fatal error: Allowed memory size of 262144 bytes exhausted (tried to allocate 261904 bytes) in Unknown on line 0 [09-Aug-2011 09:08:16] PHP Fatal error: Allowed memory size of 262144 bytes exhausted (tried to allocate 261904 bytes) in Unknown on line 0 [09-Aug-2011 09:08:16] PHP Fatal error: Allowed memory size of 262144 bytes exhausted (tried to allocate 261904 bytes) in Unknown on line 0 [09-Aug-2011 09:08:20] PHP Fatal error: Allowed memory size of 262144 bytes exhausted (tried to allocate 261904 bytes) in Unknown on line 0 [09-Aug-2011 09:08:22] PHP Fatal error: Allowed memory size of 262144 bytes exhausted (tried to allocate 261904 bytes) in Unknown on line 0 [09-Aug-2011 09:08:51] PHP Fatal error: Allowed memory size of 262144 bytes exhausted (tried to allocate 261904 bytes) in Unknown on line 0 [09-Aug-2011 09:09:56] PHP Fatal error: Allowed memory size of 262144 bytes exhausted (tried to allocate 261904 bytes) in Unknown on line 0 [09-Aug-2011 09:09:57] PHP Fatal error: Allowed memory size of 262144 bytes exhausted (tried to allocate 261904 bytes) in Unknown on line 0 [09-Aug-2011 09:12:13] PHP Fatal error: Allowed memory size of 262144 bytes exhausted (tried to allocate 261904 bytes) in Unknown on line 0 [09-Aug-2011 09:15:09] PHP Fatal error: Allowed memory size of 262144 bytes exhausted (tried to allocate 261904 bytes) in Unknown on line 0 [09-Aug-2011 09:15:09] PHP Fatal error: Allowed memory size of 262144 bytes exhausted (tried to allocate 261904 bytes) in Unknown on line 0 [09-Aug-2011 09:21:28] PHP Fatal error: Allowed memory size of 262144 bytes exhausted (tried to allocate 261904 bytes) in Unknown on line 0 [09-Aug-2011 09:21:28] PHP Fatal error: Allowed memory size of 262144 bytes exhausted (tried to allocate 261904 bytes) in Unknown on line 0 I have tried increasing the memory limit in php.ini as such: memory_limit = 512MB But that doesn't seem to solve the problem either. This is in the global php configuration in IIS When I looked at the sites one by one, I noticed that PHP seemed to have been disabled. PHP is not enabled. Register new PHP version to enable PHP via FastCGI So I tried to register the php version again C:\Program Files\PHP\v5.3\php-cgi.exe But when I try to apply the changes I get There was an error while performing this operation Details: Operation is not valid due to the current state of the object There doesn't seem to be any other information than that. I have no idea why all of a sudden php isn't available for the sites anymore. PS: I have rebooted IIS, the server, etc... This server is hosted on amazon S3, so I gave the server some more power Update These seem to be two different issues I used memory_limit=128MB instead of memory_limit=128M Notice the "M" instead of "MB" A memory_limit of 128M was not enough, had to increase it to 512M The first issue caused internal server errors for every request. Increasing to 512MB seemed to have solved the problem for a little while, but after a while the server errors return. Note that the PHP manager inside of IIS still shows there is no PHP available for the sites (the global config does see it as available) So the problem remains unsolved

    Read the article

  • php-fpm + persistent sockets = 502 bad gateway

    - by leeoniya
    Put on your reading glasses - this will be a long-ish one. First, what I'm doing. I'm building a web-app interface for some particularly slow tcp devices. Opening a socket to them takes 200ms and an fwrite/fread cycle takes another 300ms. To reduce the need for both of these actions on each request, I'm opening a persistent tcp socket which reduces the response time by the aforementioned 200ms. I was hoping PHP-FPM would share the persistent connections between requests from different clients (and indeed it does!), but there are some issues which I havent been able to resolve after 2 days of interneting, reading logs and modifying settings. I have somewhat narrowed it down though. Setup: Ubuntu 13.04 x64 Server (fully updated) on Linode PHP 5.5.0-6~raring+1 (fpm-fcgi) nginx/1.5.2 Relevent config: nginx worker_processes 4; php-fpm/pool.d pm = dynamic pm.max_children = 2 pm.start_servers = 2 pm.min_spare_servers = 2 Let's go from coarse to fine detail of what happens. After a fresh start I have 4x nginx processes and 2x php5-fpm processes waiting to handle requests. Then I send requests every couple seconds to the script. The first take a while to open the socket connection and returns with the data in about 500ms, the second returns data in 300ms (yay it's re-using the socket), the third also succeeds in about 300ms, the fourth request = 502 Bad Gateway, same with the 5th. Sixth request once again returns data, except now it took 500ms again. The process repeats for several cycles after which every 4 requests result in 2x 502 Bad Gateways and 2x 500ms Data responses. If I double all the fpm pool values and have 4x php-fpm processes running, the cycles settles in with 4x successful 500ms responses followed by 4x Bad Gateway errors. If I don't use persistent sockets, this issue goes away but then every request is 500ms. What I suspect is happening is the persistent socket keeps each php-fpm process from idling and ties it up, so the next one gets chosen until none are left and as they error out, maybe they are restarted and become available on the next round-robin loop ut the socket dies with the process. I haven't yet checked the 'slowlog', but the nginx error log shows lots of this: *188 recv() failed (104: Connection reset by peer) while reading response header from upstream, client:... All the suggestions on the internet regarding fixing nginx/php-fpm/502 bad gateway relate to high load or fcgi_pass misconfiguration. This is not the case here. Increasing buffers/sizes, changing timeouts, switching from unix socket to tcp socket for fcgi_pass, upping connection limits on the system....none of this stuff applies here. I've had some other success with setting pm = ondemand rather than dynamic, but as soon as the initial fpm-process gets killed off after idling, the persistent socket is gone for all subsequent php-fpm spawns. For the php script, I'm using stream_socket_client() with a STREAM_CLIENT_PERSISTENT flag. A while/stream_select() loop to detect socket data and fread($sock, 4096) to grab the data. I don't call fclose() obviously. If anyone has some additional questions or advice on how to get a persistent socket without tying up the php-fpm processes beyond the request completion, or maybe some other things to try, I'd appreciate it. some useful links: Nginx + php-fpm - recv() error Nginx + php-fpm "504 Gateway Time-out" error with almost zero load (on a test-server) Nginx + PHP-FPM "error 104 Connection reset by peer" causes occasional duplicate posts http://www.linuxquestions.org/questions/programming-9/php-pfsockopen-552084/ http://stackoverflow.com/questions/14268018/concurrent-use-of-a-persistent-php-socket http://devzone.zend.com/303/extension-writing-part-i-introduction-to-php-and-zend/#Heading3 http://stackoverflow.com/questions/242316/how-to-keep-a-php-stream-socket-alive http://php.net/manual/en/install.fpm.configuration.php https://www.google.com/search?q=recv%28%29+failed+%28104:+Connection+reset+by+peer%29+while+reading+response+header+from+upstream+%22502%22&ei=mC1XUrm7F4WQyAHbv4H4AQ&start=10&sa=N&biw=1920&bih=953&dpr=1

    Read the article

  • Do email forms need to be santized before sending?

    - by levi
    I have a client that keeps getting reports from godaddy's "websiteprotection.com" stating how the website is insecure. Your website contains pages that do not properly sanitize visitor-provided input to make sure it contains no malicious content or scripts. Cross-site scripting vulnerabilities let malicious users execute arbitrary HTML or script code in another visitor's browser. Output: The request string used to detect this flaw was : /cross_site_scripting.?nasl.asp The output was : HTTP/1.1 404 Not Found\r Date: Wed, 21 Mar 2012 08:12:02 GMT\r Server: Apache\r X-Pingback:http://?CLIENTSWEBSITE.com/?xmlrpc.php\r Expires: Wed, 11 Jan 1984 05:00:00 GMT\r Cache-Control: no-cache, must-revalidate, max-age=0\r Pragma: no-cache\r Set-Cookie: PHPSESSID=?1jsnhuflvd59nb4trtquston50; path=/\r Last-Modified: Wed, 21 Mar 2012 08:12:02 GMT\r Keep-Alive: timeout=15, max=100\r Connection: Keep-Alive\r Transfer-Encoding: chunked\r Content-Type: text/html; charset=UTF-8\r \r <div id="contact-form" class="widget"><form action="http://?CLIENTSWEBSITE.c om/<script>cross_site_?scripting.nasl</script>.asp" id="contactForm" meth od="post"> It looks like it has an issue with the contact form. All the contact form does is posts an ajax request to the same page, and than a PHP script mails the data (no database stuff). Is there any a security issues here? Any ideas on how I can satisfy the security scanner? Here is the form and script: <form action="<?php echo $this->getCurrentUrl(); ?>" id="contactForm" method="post"> <input type="text" name="Name" id="Name" value="" class="txt requiredField name" /> //Some more text inputs <input type="hidden" name="sendadd" id="sendadd" value="<?php echo $emailadd ; ?>" /> <input type="hidden" name="submitted" id="submitted" value="true" /><input class="submit" type="submit" value="Send" /> </form> // Some initial JS validation, if that passes an ajax post is made to the script below //If the form is submitted if(isset($_POST['submitted'])) { //Check captcha if (isset($_POST["captchaPrefix"])) { $capt = new ReallySimpleCaptcha(); $correct = $capt->check( $_POST["captchaPrefix"], $_POST["Captcha"] ); if( ! $correct ) { echo false; die(); } else { $capt->remove( $_POST["captchaPrefix"] ); } } $dateon = $_POST["dateon"]; $ToEmail = $_POST["sendadd"]; $EmailSubject = 'Contact Form Submission from ' . get_bloginfo('title'); $mailheader = "From: ".$_POST["Email"]."\r\n"; $mailheader .= "Reply-To: ".$_POST["Email"]."\r\n"; $mailheader .= "Content-type: text/html; charset=iso-8859-1\r\n"; $MESSAGE_BODY = "Name: ".$_POST["Name"]."<br>"; $MESSAGE_BODY .= "Email Address: ".$_POST["Email"]."<br>"; $MESSAGE_BODY .= "Phone: ".$_POST["Phone"]."<br>"; if ($dateon == "on") {$MESSAGE_BODY .= "Date: ".$_POST["Date"]."<br>";} $MESSAGE_BODY .= "Message: ".$_POST["Comments"]."<br>"; mail($ToEmail, $EmailSubject, $MESSAGE_BODY, $mailheader) or die ("Failure"); echo true; die(); }

    Read the article

  • Windows 7 sometimes boots in VGA mode

    - by TuxRug
    I have an Asus G50VT-x5 laptop with nVidia GeForce9800M-GS graphics. Normally, Windows boots normally, but about 20% of the time (rough estimate), it will boot with the fallback VGA driver, maxing out at 800x600 with no Aero. I've checked the system logs and there is nothing indicating an error loading the nVidia driver. It even specifies in the logs that the Nvidia Display Driver service started successfully, even though it has booted in safe graphics mode. This has been happening for a while, but it's happening a little more often now than it was before. Since the first time my system exhibited this behavior, I have updated my graphics driver a handful of times. I used System Information for Windows to check for problems there, but the only thing that stood out was the following: Core Temperature 4486449 °C (8075639 °F) Shaders Temperature 1171513530 °C (2108724330 °F) I know this reading is incorrect, because my laptop is nowhere near the surface of the sun and my desk has not burst into flames. When it's opererating normally, I get a sane reading like [Core Temperature 58 °C (136 °F)] with no Shaders Temperature listed. All I have to do to resolve the issue is reboot. I have seen no stability issues with the graphics or anything else. A long time ago, I had an issue with this computer where my framerate would suddenly drop during a 3D game from 40fps to <1fps, but after looking at the temperature readout immediately after quitting a game, I removed the bottom panel and blew the dust out of the vent and heatsink. Since then I have no drops in framerate under any situation. I have uploaded a zip containing the SIW reports for when the problem is occurring and when the computer is operating normally. I don't have a paid account so it can only be downloaded 10 times, so please only download the reports if you think you can use them. If you try to download the reports and they are no longer available, please comment and I will re-upload them. If you want to look at the files, they are on Rapidshare. EDIT It happened again, and I looked a little deeper into the System logs. When this happens, there are a lot of errors about other device drivers unable to start. All of these errors are for PnP drivers. Also, my USB keyboard and mouse take a few moments before they actually start working, although this happens sometimes the first normal boot as well. I am quite sure this is related, so I am adding the pnp tag. Also, CHKDSK will not run on boot. Even if a check is scheduled or a volume is manually set as dirty, CHKDSK will be skipped entirely, not even leaving an entry in the System logs. I tried running CHKNTFS /D, which did not work. I then manually changed my HKLM\System\CurrentControlSet\Control\Session Manager BootExecute value to the default listed on Microsoft's website. That did not work either. I ended up booting to repair mode and running CHKDSK there, which found a number of minor inconsistencies on my system drive, but none on my data drive. I have no idea if this is related. Some more information for those who don't download my SIW report file: Antivirus and Firewall are ESET Smart Security I have three different virutalization programs installed: VMware Player, Windows Virtual PC, and VirtualBox. The network adapters for these show up in the log of failed device starts. EDIT 2 I tried running sfc /scannow, which reported that it found corrupted files that could not be fixed. The CBS log is extremely cryptic. I tried booting to my install disk, launching repair mode, and doing an offline sfc from there, which produced the same result.

    Read the article

  • Performance of Cluster Shared Volume file copy from SAN

    - by Sequenzia
    I am hoping someone can help me out with a strange issue. We are running a Microsoft Failover Cluster with Server 2008 R2 and an Equallogic PS4000 SAN. Our main configuration has 2 Dell Poweredge T710 Servers in the cluster. We have CSV and Quorm setup. The servers each have 10 Broadcom 1Gb NICs. Right now 4 of the NICS are on the iSCSI network for accessing the SAN. They use MPIO and the Dell HIT pack. We have 5 VMs running on each node and everything runs smooth. No noticeable performance issues or anything. From the SAN I can see the 4 iSCSI connections from each server to each volume (CSV and Quorm). Again, it seems to perform great. The problem I am running into is with backups. I have tried a few backup programs like backupchain and Veeam. The problem is both of them are very very slow to backup the VMs. For instance I have a 500GB (fixed disc) VHD that’s running on the cluster. It takes over 18 hours to backup that VHD and that’s with compression and depuping turned off which is supposed to be the fasted. We also have a separate server that is just for backups. It has a lot of directed attached storage. As part of the troubleshooting I decided to bring that server into the cluster as a node. It now has access to the CSV and can read from C:\clusterstorage\volume1 which is where our VHDs live. This backup server only has 2 NICs. 1 NIC is going to the iSCSI network and the other is just on the main network. It has Intel NICS in it without any sort of MPIO or teaming. So with the 3rd server now in the cluster I started doing some benchmarking. I have a test VHD that’s about 7GBs that’s stored in the CSV. I have tested file copying that VHD from all 3 servers to directed attached storage in the respective server. The 2 Dell servers that are the main nodes in the cluster (they house the VMs) are reading that file at about 20Mbs/Sec. Which at that rate is way to slow for the backups. The other server which only has 1 NIC to the SAN is reading at around 100Mbs/Sec. I spent a few hours on the phone with Dell today about this . We went through all kind of tests and he was pretty dumb founded. He really has no idea why that server with only 1 NIC is reading about 5 times as fast as the servers with 4 NICS and MPIO. We looked at the network utilization of the NICs while the file copy was going on. The servers with the 4 NICs had a small increase of activity during the file copy but they only went up to around 8-10% on all 4 NICs. The other server with the 1 NIC jumped up to over 80% during the file copy. I plan on doing some more testing after hours and calling Dell back tomorrow but I really am confused (and so is Dell’s support rep) why I cannot get faster file copy access to the CSV on those servers. Anyone have any input on this? Any feedback would be greatly appreciated. Thanks in advance.

    Read the article

  • Why are my httpd mpm_prefork processes being reaped so quickly?

    - by Dan Pritts
    We've got a system running RHEL6, x64. We are using a local installation of apache 2.2.22 from source. we serve primarily: mod_perl applications (with a local installation of perl 5.16.0) tomcat applications proxied with mod_jk Here is some context; the main question is below. All of this talks to an Oracle backend. We are having issues with Oracle becoming unresponsive. We think this is because we're hitting the maximum process limit in oracle. We've upped the process limit, but now we are hitting memory pressure on the oracle server. We have tons of oracle sessions sitting idle. I can trace a bunch of them back to the httpd processes. We have mod_perl's Apache::DBI start up a new connection to the database with each httpd child that's spawned. We are concerned that these are not always getting closed out properly when the httpd's exit...and the httpd's are exiting very frequently. I know that it would be good to modify the mod_perl applications to use some better form of db connection pooling; we plan to pursue that but would like to solve our immediate problem sooner. So here's the main question. We are using the prefork MPM. The apache child processes are lasting at most a few minutes. Log analysis shows that each one is serving fewer than 50 clients before exiting; the last request each child serves is OPTIONS * HTTP/1.0 on some sort of internal connection; I'm under the impression that this is a "ping" from the master process. I've adjusted the MPM config as follows. I didn't want to raise MinSpareServers too high, because, after all, i'm trying to minimize the number of sessions to oracle. MinSpareServers 5 MaxSpareServers 30 MaxClients 150 MaxRequestsPerChild 10000 Right now we're serving 250-300 requests per minute. We've got 21 httpd's running, the eldest (other than the master, owned by root) being 3 minutes old. This rate of reaping of the apache children really seems excessive. What could be causing it? Apache was built with: $ ./configure --prefix=/opt/apache --with-ssl=/usr/lib --enable-expires --enable-ext-filter --enable-info --enable-mime-magic --enable-rewrite --enable-so --enable-speling --enable-ssl --enable-usertrack --enable-proxy --enable-headers --enable-log-forensic Apache config info: % /opt/apache/bin/httpd -V Server version: Apache/2.2.22 (Unix) Server built: Jul 23 2012 22:30:13 Server's Module Magic Number: 20051115:30 Server loaded: APR 1.4.5, APR-Util 1.4.1 Compiled using: APR 1.4.5, APR-Util 1.4.1 Architecture: 64-bit Server MPM: Prefork threaded: no forked: yes (variable process count) Server compiled with.... -D APACHE_MPM_DIR="server/mpm/prefork" -D APR_HAS_SENDFILE -D APR_HAS_MMAP -D APR_HAVE_IPV6 (IPv4-mapped addresses enabled) -D APR_USE_SYSVSEM_SERIALIZE -D APR_USE_PTHREAD_SERIALIZE -D SINGLE_LISTEN_UNSERIALIZED_ACCEPT -D APR_HAS_OTHER_CHILD -D AP_HAVE_RELIABLE_PIPED_LOGS -D DYNAMIC_MODULE_LIMIT=128 -D HTTPD_ROOT="/opt/apache" -D SUEXEC_BIN="/opt/apache/bin/suexec" -D DEFAULT_PIDLOG="logs/httpd.pid" -D DEFAULT_SCOREBOARD="logs/apache_runtime_status" -D DEFAULT_LOCKFILE="logs/accept.lock" -D DEFAULT_ERRORLOG="logs/error_log" -D AP_TYPES_CONFIG_FILE="conf/mime.types" -D SERVER_CONFIG_FILE="conf/httpd.conf" modules are compiled into apache rather than shared libs: % /opt/apache/bin/httpd -l Compiled in modules: core.c mod_authn_file.c mod_authn_default.c mod_authz_host.c mod_authz_groupfile.c mod_authz_user.c mod_authz_default.c mod_auth_basic.c mod_ext_filter.c mod_include.c mod_filter.c mod_log_config.c mod_log_forensic.c mod_env.c mod_mime_magic.c mod_expires.c mod_headers.c mod_usertrack.c mod_setenvif.c mod_version.c mod_proxy.c mod_proxy_connect.c mod_proxy_ftp.c mod_proxy_http.c mod_proxy_scgi.c mod_proxy_ajp.c mod_proxy_balancer.c mod_ssl.c prefork.c http_core.c mod_mime.c mod_status.c mod_autoindex.c mod_asis.c mod_info.c mod_cgi.c mod_negotiation.c mod_dir.c mod_actions.c mod_speling.c mod_userdir.c mod_alias.c mod_rewrite.c mod_so.c One final note - the red hat httpd, apr, and perl packages are all installed, but ldd shows that none of those libraries are linked with the running httpd.

    Read the article

  • Exchange Mail Flow

    - by Tuck918
    Hello. I have a question. We have one Exchange 2003 server and two Exchange 2007 servers. Most all of our mailboxes are on 2007 but we do still have one shared mailbox, unity mailbox and a journling mailbox on 2003. Public Folders have been set to replicate to 2007. I have set up a send connector on 2007 with a cost of 1. Receive connectors have Anonymous Users checked on 2007. On 2003 there are two connectors: the Internet Email connector and the connector that connects 2003 to 2007. We have a SPAM filtering device that email goes through before it is handed off to Exchange. The SPAM filtering device is set to send email to one of our Exchange 2007 servers. Here is my question/problem: Even though the SPAM filtering device is set to forward email to Exchange 2007, somehow all of our email is still going through the Exchange 2003 server before it finally hits the users mailboxes on the Exchange 2007 server. How can I change it so that all email goes directly to Exchange 2007 and never routes through Excahnge 2003 both ways, inbound and outbound? Would also like to add: In the EMC under Org- Hub- Send Connector there are two connectors. One is the "Internet Connector" from the 2003 box and the other is the new one I created. THe address space on the 2003 one is set to a cost of 2, no smart hosts and the 2003 box is listed as the Source Server. THe other Send Connector has an address space of 1, no smart host and has the 2 excahnge 2007 servers listed as the source servers. In EMC under Server- Hub- my two exchange 2007 servers are listed. Each one has 2 receive connectors. Both Recieve Connectors are setup the same way. THe Default Receive Connector has Anonymous Users checked. The other Recieve Connector is labled "Client" and I am not sure what it does or why its there. Anonymous Users are not checked. No smart hosts configured on 2003. Additional details Currently we have 3 excahnge servers. One exchange 2003 server and two excahnge 2007 servers. THe exchange 2003 server is the acting "bridgehead" serverand all email is routing through this server, inbound and outbound. We are wanting to decommission this server and use our two exchange 2007 servers as our mailbox servers. All of of user mailboxes are already on one of the exchange 2007 boxes and we want to put whats left on the exchange 2003 box on our other excahnge 2007 box. Both excahnge 2007 servers are currently CAS, HT and MB servers. We have a SPAM filtering device that sits between our excahnge servers and the firewall and have it configured to send messages to one of the excahgne 2007 servers but when we look at the message headers we can see that messgaes are still being routed to the excahnge 2003 box. We want to bypass the exchange 2003 in the routing process as it is dying and is starting to have major issues so everytime it goes down our email is down. Is there possible some sort of AD routing link/site link stuff going on?

    Read the article

  • RHCS: GFS2 in A/A cluster with common storage. Configuring GFS with rgmanager

    - by Pavel A
    I'm configuring a two node A/A cluster with a common storage attached via iSCSI, which uses GFS2 on top of clustered LVM. So far I have prepared a simple configuration, but am not sure which is the right way to configure gfs resource. Here is the rm section of /etc/cluster/cluster.conf: <rm> <failoverdomains> <failoverdomain name="node1" nofailback="0" ordered="0" restricted="1"> <failoverdomainnode name="rhc-n1"/> </failoverdomain> <failoverdomain name="node2" nofailback="0" ordered="0" restricted="1"> <failoverdomainnode name="rhc-n2"/> </failoverdomain> </failoverdomains> <resources> <script file="/etc/init.d/clvm" name="clvmd"/> <clusterfs name="gfs" fstype="gfs2" mountpoint="/mnt/gfs" device="/dev/vg-cs/lv-gfs"/> </resources> <service name="shared-storage-inst1" autostart="0" domain="node1" exclusive="0" recovery="restart"> <script ref="clvmd"> <clusterfs ref="gfs"/> </script> </service> <service name="shared-storage-inst2" autostart="0" domain="node2" exclusive="0" recovery="restart"> <script ref="clvmd"> <clusterfs ref="gfs"/> </script> </service> </rm> This is what I mean: when using clusterfs resource agent to handle GFS partition, it is not unmounted by default (unless force_unmount option is given). This way when I issue clusvcadm -s shared-storage-inst1 clvm is stopped, but GFS is not unmounted, so a node cannot alter LVM structure on shared storage anymore, but can still access data. And even though a node can do it quite safely (dlm is still running), this seems to be rather inappropriate to me, since clustat reports that the service on a particular node is stopped. Moreover if I later try to stop cman on that node, it will find a dlm locking, produced by GFS, and fail to stop. I could have simply added force_unmount="1", but I would like to know what is the reason behind the default behavior. Why is it not unmounted? Most of the examples out there silently use force_unmount="0", some don't, but none of them give any clue on how the decision was made. Apart from that I have found sample configurations, where people manage GFS partitions with gfs2 init script - https://alteeve.ca/w/2-Node_Red_Hat_KVM_Cluster_Tutorial#Defining_The_Resources or even as simply as just enabling services such as clvm and gfs2 to start automatically at boot (http://pbraun.nethence.com/doc/filesystems/gfs2.html), like: chkconfig gfs2 on If I understand the latest approach correctly, such cluster only controls whether nodes are still alive and can fence errant ones, but such cluster has no control over the status of its resources. I have some experience with Pacemaker and I'm used to that all resources are controlled by a cluster and an action can be taken when not only there are connectivity issues, but any of the resources misbehave. So, which is the right way for me to go: leave GFS partition mounted (any reasons to do so?) set force_unmount="1". Won't this break anything? Why this is not the default? use script resource <script file="/etc/init.d/gfs2" name="gfs"/> to manage GFS partition. start it at boot and don't include in cluster.conf (any reasons to do so?) This may be a sort of question that cannot be answered unambiguously, so it would be also of much value for me if you shared your experience or expressed your thoughts on the issue. How does for example /etc/cluster/cluster.conf look like when configuring gfs with Conga or ccs (they are not available to me since for now I have to use Ubuntu for the cluster)? Thanks you very much!

    Read the article

  • hostapd running on Ubuntu Server 13.04 only allows single station to connect when using wpa

    - by user450688
    Problem Only a single station can connect to hostapd at a time. Any single station can connect (W8, OSX, iOS, Nexus) but when two or more hosts are connected at the same time the first client loses its connectivity. However there are no connectivity issues when WPA is not used. Setup Linux (Ubuntu server 13.04) wireless router (with separate networks for wired WAN, wired LAN, and Wireless LAN. iptables-save output: *nat :PREROUTING ACCEPT [0:0] :INPUT ACCEPT [0:0] :OUTPUT ACCEPT [0:0] :POSTROUTING ACCEPT [0:0] -A POSTROUTING -s 10.0.0.0/24 -o p4p1 -j MASQUERADE -A POSTROUTING -s 10.0.1.0/24 -o p4p1 -j MASQUERADE COMMIT *mangle :PREROUTING ACCEPT [13:916] :INPUT ACCEPT [9:708] :FORWARD ACCEPT [4:208] :OUTPUT ACCEPT [9:3492] :POSTROUTING ACCEPT [13:3700] COMMIT *filter :INPUT DROP [0:0] :FORWARD DROP [0:0] :OUTPUT ACCEPT [9:3492] -A INPUT -i p4p1 -m state --state RELATED,ESTABLISHED -j ACCEPT -A INPUT -i p4p1 -p tcp -m tcp --dport 22 -m state --state NEW -j ACCEPT -A INPUT -i eth0 -j ACCEPT -A INPUT -i wlan0 -j ACCEPT -A INPUT -i lo -j ACCEPT -A FORWARD -i p4p1 -m state --state RELATED,ESTABLISHED -j ACCEPT -A FORWARD -i eth0 -j ACCEPT -A FORWARD -i wlan0 -j ACCEPT -A FORWARD -i lo -j ACCEPT COMMIT /etc/hostapd/hostapd.conf #Wireless Interface interface=wlan0 driver=nl80211 ssid=<removed> hw_mode=g channel=6 max_num_sta=15 auth_algs=3 ieee80211n=1 wmm_enabled=1 wme_enabled=1 #Configure Hardware Capabilities of Interface ht_capab=[HT40+][SMPS-STATIC][GF][SHORT-GI-20][SHORT-GI-40][RX-STBC12] #Accept all MAC address macaddr_acl=0 #Shared Key Authentication wpa=1 wpa_passphrase=<removed> wpa_key_mgmt=WPA-PSK wpa_pairwise=CCMP rsn_pairwise=CCMP ###IPad Connectivevity Repair ieee8021x=0 eap_server=0 Wireless Card #lshw output product: RT2790 Wireless 802.11n 1T/2R PCIe vendor: Ralink corp. physical id: 0 bus info: pci@0000:03:00.0 logical name: mon.wlan0 version: 00 serial: <removed> width: 32 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list logical wireless ethernet physical configuration: broadcast=yes driver=rt2800pci driverversion=3.8.0-25-generic firmware=0.34 ip=10.0.1.254 latency=0 link=yes multicast=yes wireless=IEEE 802.11bgn #iw list output Band 1: Capabilities: 0x272 HT20/HT40 Static SM Power Save RX Greenfield RX HT20 SGI RX HT40 SGI RX STBC 2-streams Max AMSDU length: 3839 bytes No DSSS/CCK HT40 Maximum RX AMPDU length 65535 bytes (exponent: 0x003) Minimum RX AMPDU time spacing: 2 usec (0x04) HT RX MCS rate indexes supported: 0-15, 32 TX unequal modulation not supported HT TX Max spatial streams: 1 HT TX MCS rate indexes supported may differ Frequencies: * 2412 MHz [1] (27.0 dBm) * 2417 MHz [2] (27.0 dBm) * 2422 MHz [3] (27.0 dBm) * 2427 MHz [4] (27.0 dBm) * 2432 MHz [5] (27.0 dBm) * 2437 MHz [6] (27.0 dBm) * 2442 MHz [7] (27.0 dBm) * 2447 MHz [8] (27.0 dBm) * 2452 MHz [9] (27.0 dBm) * 2457 MHz [10] (27.0 dBm) * 2462 MHz [11] (27.0 dBm) * 2467 MHz [12] (disabled) * 2472 MHz [13] (disabled) * 2484 MHz [14] (disabled) Bitrates (non-HT): * 1.0 Mbps * 2.0 Mbps (short preamble supported) * 5.5 Mbps (short preamble supported) * 11.0 Mbps (short preamble supported) * 6.0 Mbps * 9.0 Mbps * 12.0 Mbps * 18.0 Mbps * 24.0 Mbps * 36.0 Mbps * 48.0 Mbps * 54.0 Mbps max # scan SSIDs: 4 max scan IEs length: 2257 bytes Coverage class: 0 (up to 0m) Supported Ciphers: * WEP40 (00-0f-ac:1) * WEP104 (00-0f-ac:5) * TKIP (00-0f-ac:2) * CCMP (00-0f-ac:4) Available Antennas: TX 0 RX 0 Supported interface modes: * IBSS * managed * AP * AP/VLAN * WDS * monitor * mesh point software interface modes (can always be added): * AP/VLAN * monitor valid interface combinations: * #{ AP } <= 8, total <= 8, #channels <= 1 Supported commands: * new_interface * set_interface * new_key * new_beacon * new_station * new_mpath * set_mesh_params * set_bss * authenticate * associate * deauthenticate * disassociate * join_ibss * join_mesh * set_tx_bitrate_mask * set_tx_bitrate_mask * action * frame_wait_cancel * set_wiphy_netns * set_channel * set_wds_peer * Unknown command (84) * Unknown command (87) * Unknown command (85) * Unknown command (89) * Unknown command (92) * testmode * connect * disconnect Supported TX frame types: * IBSS: 0x00 0x10 0x20 0x30 0x40 0x50 0x60 0x70 0x80 0x90 0xa0 0xb0 0xc0 0xd0 0xe0 0xf0 * managed: 0x00 0x10 0x20 0x30 0x40 0x50 0x60 0x70 0x80 0x90 0xa0 0xb0 0xc0 0xd0 0xe0 0xf0 * AP: 0x00 0x10 0x20 0x30 0x40 0x50 0x60 0x70 0x80 0x90 0xa0 0xb0 0xc0 0xd0 0xe0 0xf0 * AP/VLAN: 0x00 0x10 0x20 0x30 0x40 0x50 0x60 0x70 0x80 0x90 0xa0 0xb0 0xc0 0xd0 0xe0 0xf0 * mesh point: 0x00 0x10 0x20 0x30 0x40 0x50 0x60 0x70 0x80 0x90 0xa0 0xb0 0xc0 0xd0 0xe0 0xf0 * P2P-client: 0x00 0x10 0x20 0x30 0x40 0x50 0x60 0x70 0x80 0x90 0xa0 0xb0 0xc0 0xd0 0xe0 0xf0 * P2P-GO: 0x00 0x10 0x20 0x30 0x40 0x50 0x60 0x70 0x80 0x90 0xa0 0xb0 0xc0 0xd0 0xe0 0xf0 * Unknown mode (10): 0x00 0x10 0x20 0x30 0x40 0x50 0x60 0x70 0x80 0x90 0xa0 0xb0 0xc0 0xd0 0xe0 0xf0 Supported RX frame types: * IBSS: 0x40 0xb0 0xc0 0xd0 * managed: 0x40 0xd0 * AP: 0x00 0x20 0x40 0xa0 0xb0 0xc0 0xd0 * AP/VLAN: 0x00 0x20 0x40 0xa0 0xb0 0xc0 0xd0 * mesh point: 0xb0 0xc0 0xd0 * P2P-client: 0x40 0xd0 * P2P-GO: 0x00 0x20 0x40 0xa0 0xb0 0xc0 0xd0 * Unknown mode (10): 0x40 0xd0 Device supports RSN-IBSS. HT Capability overrides: * MCS: ff ff ff ff ff ff ff ff ff ff * maximum A-MSDU length * supported channel width * short GI for 40 MHz * max A-MPDU length exponent * min MPDU start spacing Device supports TX status socket option. Device supports HT-IBSS.

    Read the article

  • Why would VMWare to go defunct? How to recover from/prevent it?

    - by Josh
    I am running VMWare Server 2.0.2 (Build 203138) on a dual core Intel i5 with Ubuntu Server 10.04 LTS system (kernel 2.6.32-22-server #33-Ubuntu SMP). Disk Subsystem is a software RAID5 array. The system has been set up for a little over a week. For the past 5 days I have been running at leat 3 VMs (Linux and a variety of Windows OSes) with no issues whatsoever. But while I was installing Linux onto a new VM, suddenly all VMs became unresponsive, including the one I was installing to. I could not log in to the VMWare Management Interface, and the system was somewhat unresponsive via SSH. When I looked at top, I saw: top - 16:14:51 up 6 days, 1:49, 8 users, load average: 24.29, 24.33 17.54 Tasks: 203 total, 7 running, 195 sleeping, 0 stopped, 1 zombie Cpu(s): 0.2%us, 25.6%sy, 0.0%ni, 74.3%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st Mem: 8056656k total, 5927580k used, 2129076k free, 20320k buffers Swap: 7811064k total, 240216k used, 7570848k free, 5045884k cached PID USER PR NI VIRT RES SHR S %CPU %MEM TIME+ COMMAND 21549 root 39 19 0 0 0 Z 100 0.0 15:02.44 [vmware-vmx] <defunct> 2115 root 20 0 0 0 0 S 1 0.0 170:32.08 [vmware-rtc] 2231 root 21 1 1494m 126m 100m S 1 1.6 892:58.05 /usr/lib/vmware/bin/vmware-vmx -# product=2; 2280 jnet 20 0 19320 1164 800 R 0 0.0 30:04.55 top 12236 root 20 0 833m 41m 34m S 0 0.5 88:34.24 /usr/lib/vmware/bin/vmware-vmx -# product=2; 1 root 20 0 23704 1476 920 S 0 0.0 0:00.80 /sbin/init 2 root 20 0 0 0 0 S 0 0.0 0:00.01 [kthreadd] 3 root RT 0 0 0 0 S 0 0.0 0:00.00 [migration/0] 4 root 20 0 0 0 0 S 0 0.0 0:00.84 [ksoftirqd/0] 5 root RT 0 0 0 0 S 0 0.0 0:00.00 [watchdog/0] 6 root RT 0 0 0 0 S 0 0.0 0:00.00 [migration/1] The VMWare process for the virtual machine I was installing into became a zombie. Yet, it was still consuming 100% of the CPU time on one of the cores, and I couldn't reach it or any other virtual machines. (I was logged in to one virtual machine over SSH, another via X11, and a third via VNC. All three connections died). When I ran ps -ef and similar commands, I found that the defunct vmware-vmx process had it's parent PID set to init (1). I also used lsof -p 21549 and found that the defunct process had no open files. Yet it was using 100% of CPU time... I was unable to kill any vmware-vmx processes, including the defunct one, even with kill -9. As a last resort to resolve the situation I tried to reboot the box, however shutdown, halt, reboot, and init 6 all failed to reboot/shutdown, even when given appropriate --force settings. ControlAltDel produced a message about rebooting on the console, but the system would not reboot. I had to hard power-cycle the box to resolve the situation. (See my other question, Should I worry about the integrity of my linux software RAID5 after a crash or kernel panic?) What would cause a scenario like this? What else could I have done to resolve it besides a hard reboot? What can I do to prevent such a situation in the future?

    Read the article

  • nginx serving php for download (previously: nginx multiple location alias 404)

    - by torsten
    Im having issues with the alias location in the following configuration server { listen 80; server_name localhost; root /srv/http/share; index index.php; include php.conf; location / { try_files $uri $uri/ /index.php$is_args$args; } location /phpmemcachedadmin { alias /srv/http/phpmemcachedadmin; } location /webgrind { alias /srv/http/webgrind; } } while / works well, im getting a 404 for /webgrind and /phpmemcachedadmin. If i switch the root directory to /srv/http and alias the / location, die /phpmemcachedadmin and webgrind work, but not the / location. UPDATE: I managed the probems getting all location to work, so here is the updated config #user html; worker_processes 2; #error_log logs/error.log; #error_log logs/error.log notice; #error_log logs/error.log info; #pid logs/nginx.pid; events { worker_connections 1024; } http { include mime.types; default_type application/octet-stream; sendfile on; keepalive_timeout 65; gzip on; server { listen 80; server_name localhost; location / { root /srv/http/share; index index.php; try_files $uri $uri/ /index.php$is_args$args; include php.conf; } location /phpmemcachedadmin { root /srv/http; index index.php; try_files $uri $uri/ /index.php$is_args$args; include php.conf; } location /webgrind { root /srv/http; index index.php; try_files $uri $uri/ /index.php$is_args$args; include php.conf; } } } The php.conf looks like this: location ~ \.php$ { try_files $uri =404; fastcgi_pass unix:/run/php-fpm/php-fpm.sock; fastcgi_index index.php; include fastcgi.conf; } while the fastcgi.conf like this: fastcgi_param SCRIPT_FILENAME $document_root$fastcgi_script_name; fastcgi_param QUERY_STRING $query_string; fastcgi_param REQUEST_METHOD $request_method; fastcgi_param CONTENT_TYPE $content_type; fastcgi_param CONTENT_LENGTH $content_length; fastcgi_param SCRIPT_NAME $fastcgi_script_name; fastcgi_param REQUEST_URI $request_uri; fastcgi_param DOCUMENT_URI $document_uri; fastcgi_param DOCUMENT_ROOT $document_root; fastcgi_param SERVER_PROTOCOL $server_protocol; fastcgi_param HTTPS $https if_not_empty; fastcgi_param GATEWAY_INTERFACE CGI/1.1; fastcgi_param SERVER_SOFTWARE nginx/$nginx_version; fastcgi_param REMOTE_ADDR $remote_addr; fastcgi_param REMOTE_PORT $remote_port; fastcgi_param SERVER_ADDR $server_addr; fastcgi_param SERVER_PORT $server_port; fastcgi_param SERVER_NAME $server_name; # PHP only, required if PHP was built with --enable-force-cgi-redirect fastcgi_param REDIRECT_STATUS 200; But there is a problem serving phpmemcachedadmin. If i call localhost/phpmemcachedadmin/index.php it works quite well (i get a log that i got served the file in access log). On the other hand, if i just call localhost/phpmemcachedadmin/ he serves me the file for download. Neither the error.log nor the access.log log anything when i get served the the file for download. Any ideas?

    Read the article

  • Hanging of host network connections when starting KVM guest on bridge

    - by Chris Phillips
    Hi, I've a KVM system upon which I'm running a network bridge directly between all VM's and a bond0 (eth0, eth1) on the host OS. As such, all machines are presented on the same subnet, available outside of the box. The bond is doing mode 1 active / passive, with an arp_ip_target set to the default gateway, which has caused some issues in itself, but I can't see the bond configs mattering here myself. I'm seeing odd things most times when I stop and start a guest on the platform, in that on the host I lose network connectivity (icmp, ssh) for about 30 seconds. I don't lose connectivity on the other already running VM's though... they can always ping the default GW, but the host can't. I say "about 30 seconds" but from some tests it actually seems to be 28 seconds usually (or at least, I lose 28 pings...) and I'm wondering if this somehow relates to the bridge config. I'm not running STP on the bridge at all, and the forwarding delay is set to 1 second, path cost on the bond0 lowered to 10 and port priority of bond0 also lowered to 1. As such I don't think that the bridge should ever be able to think that bond0 is not connected just fine (as continued guest connectivity implies) yet the IP of the host, which is on the bridge device (... could that matter?? ) becomes unreachable. I'm fairly sure it's about the bridged networking, but at the same time as this happens when a VM is started there are clearly loads of other things also happening so maybe I'm way off the mark. Lack of connectivity: # ping 10.20.11.254 PING 10.20.11.254 (10.20.11.254) 56(84) bytes of data. 64 bytes from 10.20.11.254: icmp_seq=1 ttl=255 time=0.921 ms 64 bytes from 10.20.11.254: icmp_seq=2 ttl=255 time=0.541 ms type=1700 audit(1293462808.589:325): dev=vnet6 prom=256 old_prom=0 auid=42949672 95 ses=4294967295 type=1700 audit(1293462808.604:326): dev=vnet7 prom=256 old_prom=0 auid=42949672 95 ses=4294967295 type=1700 audit(1293462808.618:327): dev=vnet8 prom=256 old_prom=0 auid=42949672 95 ses=4294967295 kvm: 14116: cpu0 unimplemented perfctr wrmsr: 0x186 data 0x130079 kvm: 14116: cpu0 unimplemented perfctr wrmsr: 0xc1 data 0xffdd694a kvm: 14116: cpu0 unimplemented perfctr wrmsr: 0x186 data 0x530079 64 bytes from 10.20.11.254: icmp_seq=30 ttl=255 time=0.514 ms 64 bytes from 10.20.11.254: icmp_seq=31 ttl=255 time=0.551 ms 64 bytes from 10.20.11.254: icmp_seq=32 ttl=255 time=0.437 ms 64 bytes from 10.20.11.254: icmp_seq=33 ttl=255 time=0.392 ms brctl output of relevant bridge: # brctl showstp brdev brdev bridge id 8000.b2e1378d1396 designated root 8000.b2e1378d1396 root port 0 path cost 0 max age 19.99 bridge max age 19.99 hello time 1.99 bridge hello time 1.99 forward delay 0.99 bridge forward delay 0.99 ageing time 299.95 hello timer 0.50 tcn timer 0.00 topology change timer 0.00 gc timer 0.04 flags vnet5 (3) port id 8003 state forwarding designated root 8000.b2e1378d1396 path cost 100 designated bridge 8000.b2e1378d1396 message age timer 0.00 designated port 8003 forward delay timer 0.00 designated cost 0 hold timer 0.00 flags vnet0 (2) port id 8002 state forwarding designated root 8000.b2e1378d1396 path cost 100 designated bridge 8000.b2e1378d1396 message age timer 0.00 designated port 8002 forward delay timer 0.00 designated cost 0 hold timer 0.00 flags bond0 (1) port id 0001 state forwarding designated root 8000.b2e1378d1396 path cost 10 designated bridge 8000.b2e1378d1396 message age timer 0.00 designated port 0001 forward delay timer 0.00 designated cost 0 hold timer 0.00 flags I do see the new port listed as learning, but in line with the forward delay, only for 1 or 2 seconds when polling the brctl output on a loop. All pointers, tips or stabs in the dark appreciated.

    Read the article

  • Hardware recommendations / parts list for a modern, quiet ZFS NAS box - 2011-Feb edition [closed]

    - by dandv
    I want to build some really reliable storage for my data, and it seems that ZFS is the only filesystem at the moment that does live checksumming. That rules out DroboPro, so I'm looking to building a quiet ZFS NAS that would start with 4 2TB or larger hard drives. I'd like this system to be very reliable and relatively future-proof for 2-3 years, so I'm willing to invest some $$$ and buy higher end components. I did see questions here and on other forums about low-cost servers, but I'm not looking for those. I'd be super happy to go for an off-the-shelf solution, but I haven't found one that's quiet. I started doing the research (summarized on my wiki), but I realized that it just gets too complicated for what I know as a software dude, and I'm entering the analysis paralysis area. At this point, I'm basically looking for a parts list for a configuration that will work (and is modern), and I know there are folks around here who are way more competent than me. I've built computers and am comfortable assembling one and messing with *nix; I can follow guides; I just want to end the decision process for the hardware and software configuration. What I've researched so far (not that these are very modern components): Case: I think I've settled on the Antec Twelve Hundred case because it cools well, is quiet, and simply has 12 bays that allow elastic mounting. The SilverStone Raven is its counter-candidate, but I find its construction quite odd. For the PSU, I'm torn between Antec CP-850 and Nexus RX-8500, but I did this research more than a year ago. The Nexus has a very uniform power profile, and I'd rather not have the Antec spin up and down based on load. On the other hand, I'm not sure how often my file server will draw more than 400W under use. For the hard drives, I've read that WD Black drives are actually WD RE3 with a software setting changed. I'd also like to buy different drive types, not just 4 WDs. Recommendations? Right now I have a 2TB Hitachi Deskstar 7K300. For the motherboard, CPU and RAM I have no idea, other than the RAM must be ECC. I already asked a question here about ECC RAM, but I was misguided and was looking for a motherboard that would support USB 3.0 as well. I've learned to go with eSATA, or worry about USB later. Then there's the (liquid) cooling, Wi-Fi card, and FreeBSD vs. OpenSolaris Express. Lastly, I'm wondering if I can make this PC into a media server by adding a Blu-ray drive and a good sound card. But support for Blu-Ray is spotty on Linux, and I don't know if Windows 7 on VirtualBox would get sufficient hardware access to output HDMI or SPDIFF signals. (Running OpenSolaris virtualized is not an option because of the reliability risk.) Then there are HDCP concerns. Suggestions on that would be appreciated as well, but I don't want us to get sidetracked. A specific shopping list on the core components would be great, so I can start ordering, and in the meantime educate myself with regards to the other issues. Finally, I think this could become a great FAQ for those technically inclined to build their own ZFS server, but confused by the dizzying array of options out there, and I promise to compile the results and share my experience building and benchmarking the server.

    Read the article

  • File copying utility like rsync with error handling like ddrescue, for data recovery from a hard drive with bad sectors or hardware failure

    - by purefusion
    I have a hard drive with either bad blocks or sectors that are failing to read due to potential mechanical issues, such as a bad disk head, bad motor, or some other issue that is causing the hard drive to read data excruciatingly slowly and with lots of read errors. I'm seeing an average of 50 KB/sec, with some reads dropping below 10 KB/sec, and frequently it gets stuck on a file or sector altogether, usually for quite a long time—from 2-10 minutes or more (when using rsync, before it times out). Speed seems to vary wildly, and it gets stuck on files a lot, and when it finally gets "unstuck" it only seems to last for a short burst before it gets stuck again. The drive is also very quiet with only an occasional sound of files copying (usually when it gets stuck/unstuck for a brief time, before getting stuck again). Thus, there are none of those evil sounds that are normally associated with HDD death. Someone suggested that the problems sounded like they might be caused by a misaligned disk head, which requires a lot of re-reads before it finally reads data with success. Sounds plausible, but I digress... Anyway, the problem with rsync is that it seems to have no decent error handling support. Obviously, it wasn't meant for use in recovering data from failing hard drives, but all the so-called "data recovery" utilities out there that are meant for such use usually focus on recovery of deleted files or messed up partitions, rather than copying files off dying hard drives. Deleted file recovery is not what I need, obviously, so perhaps you can understand my disappointment in not being able to find what I'm after yet. Naturally, this is where you'd probably say "You should use ddrescue!" Well, that's all fine and dandy, but I've already got most of the data backed up, so I just want to recover certain files. I'm not concerned with trying to recover a full partition block-by-block as ddrescue does. I am only interested in rescuing just specific files and directories. Ideally, what I'd like is some sort of cross between rsync and ddrescue: something that lets me specify source and destination as directories of normal files like rsync (rather than two full partitions as ddrescue requires), with a way to skip files with errors in an initial run, and then allows me to attempt recovery of those files with errors in a later run (with a slightly altered command, of course), perhaps even offering an option to specify the number of retry attempts ...just like how ddrescue works with blocks, only I want a utility that works with specific files/directories like rsync does. So am I daydreaming here, or does something out there exist that can do this? Or, maybe even a way to make rsync or ddrescue work in such a way? I'm really open to whatever solutions might work, so long as they let me choose which files I want to "rescue", and can skip files with errors in the initial run, and try/retry those errors again later. So far I've tried rsync with the following options, but it often gets stuck on a file for longer than the timeout, and ideally I'd just like it to move on to the next file and come back later to the files it gets stuck on. I don't think that's possible though. Anyway, here's what I've been using up till now: rsync -avP --stats --block-size=512 --timeout=600 /path/to/source/* /path/to/destination/

    Read the article

  • Nginx - Redirect any Subdomain to File without Rewriting

    - by Waffle
    Recently I have switched from Apache to Nginx to increase performance on a web server running Ubuntu 11.10. I have been having issues trying to figure out how certain things work in Nginx compared to Apache, but one issue has been stumping me and I have not been able to find the answer online. My problem is that I need to be able to redirect (not rewrite) any sub-domain to a file, but that file needs to be able to get the sub-domain part of the URL in order to do a database look-up of that sub-domain. So far, I have been able to get any sub-domain to rewrite to that file, but then it loses the text of the sub-domain I need. So, for example, I would like test.server.com to redirect to server.com/resolve.php, but still remain as test.server.com. If this is not possible, the thing that I would need at the very least would be something such as going to test.server.com would go to server.com/resolve.php?=test . One of these options must be possible in Nginx. My config as it stands right now looks something like this: server { listen 80; ## listen for ipv4; this line is default and implied listen [::]:80 default ipv6only=on; ## listen for ipv6 root /usr/share/nginx/www; index index.php index.html index.htm; # Make site accessible from http://localhost/ server_name www.server.com server.com; location / { # First attempt to serve request as file, then # as directory, then fall back to index.html try_files $uri $uri/ /index.html; } location /doc { root /usr/share; autoindex on; allow 127.0.0.1; } location /images { root /usr/share; autoindex off; } #error_page 404 /404.html; # redirect server error pages to the static page /50x.html # #error_page 500 502 503 504 /50x.html; #location = /50x.html { # root /usr/share/nginx/www; #} # proxy the PHP scripts to Apache listening on 127.0.0.1:80 # #location ~ \.php$ { # proxy_pass http://127.0.0.1; #} # pass the PHP scripts to FastCGI server listening on 127.0.0.1:9000 # location ~ \.php$ { fastcgi_pass unix:/tmp/php5-fpm.sock; fastcgi_index index.php; include fastcgi_params; } # deny access to .htaccess files, if Apache's document root # concurs with nginx's one # #location ~ /\.ht { # deny all; #} } server { listen 80 default; server_name *.server.com; rewrite ^ http://www.server.com/resolve.php; } As I said before, I am very new to Nginx, so I have a feeling the answer is pretty simple, but no examples online seem to deal with just redirects without rewrites or rewriting with the sub-domain section included. Any help on what to do would be most appreciated and if any one has a better idea to accomplish what I need, I am also open to ideas. Thank you very much.

    Read the article

  • Supermicro IPMI on MBD-X8DAH+-F-O motherboard. Keyboard and mouse do not work after booting Windows Server 2008 R2

    - by LDelgado
    Hell Everyone, I built a server with the mentioned motherboard. I installed Windows Server 2008 R2 Enterprise on this server. IPMI is integrated on the motherboard with its own dedicated NIC. I've got that NIC configured with its own IP address. I can remote into it using IPMI, and I can remotely control the server settings before booting the OS ( BIOS, RAID configuration, etc). When the OS boots, I lose the mouse and keyboard. I cannot use the keyboard or mouse when installing the OS either. So the Keyboard and Mouse only work when no OS is loaded. Once the OS loads I lose it - that is my problem. I've been doing some research and trying a few things, but I have not been successful in fixing this issue. I may be wrong, but based on the things I've found online, it seems that the problem could be caused by the way the OS handles USB. The server is headless. There is no keyboard, mouse, or monitor plugged into it. When I boot up the OS and remote into it, I cannot see a mouse or keyboard listed in the Device Manager. Based on what I've read, it seems that the OS should detect a mouse and a keyboard when connecting remotely via IPMI. The following are the solutions I've tried. Nothing has worked so far: I've updated the firmware of the IPMI component to the latest firmware - 1.33. I made sure that the mouse mode was set to Absolute (Windows OS). I've loaded the factory defaults several times. I've enabled Port64h/60h Emulation under the USB settings in the BIOS. I've disabled USB legacy support in the BIOS. I made sure the firewall wasn't blocking IPMI (disabled the firewall). And that's about it. I've found threads in some forums from people having the same issue as me, but they were not running the same OS. They were either running Linux or FreeBSD. Most of them fixed their problem by selecting the right mouse mode (Linux in their case). There was one other that solved the problem by disabling USB Mass Storage mode. He stated "When I set it to disable USB Mass Storage when no image is loaded, the ukbd came alive, and I'm typing this on the IPMI Console. " source: http://freebsd.1045724.n5.nabble.com/IPMI-Console-No-luck-once-OS-is-booted-td3967868.html I suspect the solution described in the previous paragraph is somehow related to my problem. I've found several threads on the internet with issues describing the same problem, but none of them were with Windows Server 2008 R2. Again, I may be wrong, but it seems like that could be the issue. I just don't know how I go about applying a solution in Windows Server 2008 R2. In any case, I could use your expertise. Maybe I am missing something, or maybe I'm on the right track. Your help is much appreciated. Thank you in advance,

    Read the article

  • Dell Latitude E6430 Docking Station + Dual Monitor + Laptop Screen Tri-Monitor setup

    - by Larry
    I have a company issued laptop and docking station as well as two monitors The specifications of the hardware are as follows; Laptop: Latitude E6430 BIOS: A02.00 Processor: i7-3720QM CPU @ 2.60 (8 CPUs) Memory: 4096MB RAM Page file: 1825MB used, 4793MB available DirectX 11 Display Driver/Chip: MVIDIA NVS 5200M DAC: Integrated RAMDAC Aprox Total Memory: 2376 (Above 3 details same for both displays) Current Display Mode (Display 1): 1600x900 Current Display Mode (Display 2): 1440x900 the docking station is a Dell Latitude E6420 Docking Station PR03X Port Replicator and I don't think the monitor model is particularly relevant to resolving this issue but they are both Acer V193Ws The story goes like this; the laptop works fine if I VGA one monitor into the laptop through the vga port on the back of the lefthand side of the laptop I can achieve dual monitor display fine (laptop screen + monitor) if I plug the laptop into the docking station and use the vga port in the back of the docking station I can dual monitor fine (laptop screen + monitor) if I plug the laptop into the docking station, the laptop's lefthand side VGA port no longer seems to function at all I've spoken to internal IT about this issue and they're going to get me some kind of VGA splitter or a DVI-VGA adapter to use with the docking station for the second Acer Monitor, but that isn't going to happen for a few days. So I guess what I'm wondering is; is there any way to continue to use the side VGA port on my laptop while using the docking station VGA port? and as a secondary 'followup' pending resolution of the initial issue with getting both monitors up and running (at the moment I have both monitors on my desk but am just using my laptop screen as one of my dual monitor display with one of the monitors [the one connected to dock]), is there any way to CONTINUE to use my laptop monitor to in effect have a triple monitor display (2 monitors + docked laptop)? I am wondering this because internal IT told me that they were aware of some issues with the particular display drivers in my box and triple monitor displays but weren't really going to look TOO much in-depth into that (which is perfectly understandable) since getting the adapter for the dual monitors up and running was the greater priority within their purview. So this is a two parter; Can I dual monitor using two vga cables with 1 docking station vga port and one laptop vga port? is there a setting that can be tweaked somewhere? because plugging the box into the station seems to make the side port stop working and... Is there any reasonably simple and cost-effective work around (e.g. I am find with shelling out maybe a few dollars out of my own pocket for some hardware or software to make my company box tri-display capable) but if this requires some extensive rebuild or new OSs or doing stuff to the BIOS I'd rather have a straight answer about this being untenable as a slight modification to a (once again) company laptop and stop wasting time looking into it Thanks! and please let me know if you guys need any more details (tech specs or something) to answer this question [EDIT] 2/10/2014 Just an update; turned out it really was just a hardware limitation issue. The old laptop just couldn't hack it. Got a new laptop with a better video card and different monitors from my company and am successfully using a triple display currently (2 monitors + laptop screen)

    Read the article

  • Problems with XP, Office, and PC in general - any ideas?

    - by molecule
    Hi all This may not make a whole lot of sense so pls bear with me... I am about to perform a routine check on one of my user's PC. Some background - the PC has a Xeon processor and 4Gb of RAM and running XP SP3 He has 2xHDD and pagefile is hosted on the secondary HDD (D:) and min/max values are set to 4096. NO pagefile on C: This user has 6 monitors so he has an NVIDIA Quadro NVS440 hosting 4xmonitors and an NVIDIA Quadro NVS290 hosting 2xmonitors. There is a video card driver from NVIDIA which is compatible with both NVS440 and NVS290 and he is on the latest version of that driver. (Note: Make of video cards are different - one is from leadtek and the other from Nvidia) He is a heavy Bloomberg, Outlook, Word, and Excel user and runs two Citrix applications. Other apps are FoxIt PDF and IE. Problems - Outlook and Excel frequently crashes - I am going to perform an Outlook and Excel repair and also check/remove unnecessary addins - will he lose any customizations if I repaired and chose "Restore my shortcuts while repairing" and do not select "Discard my customized settings and restore default settings". Does repair really repair anything? FYI - It stopped crashing ever since i moved a large spreadsheet he has open to his local HDD instead of over the network. This spreadsheet "refreshes" constantly as it is pulling live data to update cells and I suspect it was auto-saving so frequently that it caused crashes if saving over the network. At times, his right click completely fails to respond. His left click works fine but he can't right click on anything in any Window and even on the desktop. Sometimes, he needs to start to close certain applications such as Adobe and the right click will start functioning again. I removed Adobe and installed FoxIt as I figured it was a resource issue but I do not think so as he does have sufficient resources when the problem is happening. Sometimes he can't bring task manager up until he kills certain apps. Definitely sounds like a resource issue but I am not confident that is the root cause. Also not sure if this is related to one of the apps installed but his Start bar flickers (does not completely disappear) intermittently from time to time. The taskbar icons which are hidden appear and then get hidden again as if it was having "fits". I have performed reg scans, malware scans etc but problems do not go away. I am planning to perform sfc /scannow and office repair but would like to know if anyone has any other suggestions. What about setting a "small" pagefile on C:. I have heard that this is recommended and may be the reason why a minidmp file was not generated when he encountered a blue screen. Also, any feedback on his video cards? Do you think different models would cause problems? The drivers seem to work but he only has 2.5Gb out of 4Gb available RAM as I believe the video card chomped up a portion of this. I have recommended creating a new profile for him but due to the amount of customisations he has and the amount of time and effort it will take to get him up and running again, he prefers to bear with the problem than to go down that path. However, at least once a week, his PC acts up and I can't think of any other tools or techniques to rectify his problems. I guess we are at a stage where we just want to "stabilize" things so he won't encounter issues that frequently. Any feedback is very much appreciated.

    Read the article

  • How to diagnose computer lockups and freezes?

    - by Scott Mitchell
    I built a desktop computer a couple years back with the following specs: CPU: Intel Core 2 Quad Q9300 Yorkfield 2.5GHz 6 MB L2 Cache LGA 775 95W Quad-Core Processor BX80580Q9300 Motherboard: EVGA 122-CK-NF68-T1 LGA 775 NVIDIA nForce 680i SLI ATX Intel Motherboard Video Card: Two EVGA 256-P2-N758-TR GeForce 8600GT SCC 256 MB 128-bit GDDR3 PCI Express x16 SLI Supported Video Card PSU: SeaSonic S12 Energy Plus SS-550HT 550W ATX12V V2.3 / EPS12V V2.91 SLI Certified CrossFire Ready 80 PLUS Certified Active PFC Power Supply Memory: Two G.SKILL 4 GB (2 x 2 GB) 240-Pin DDR2 SDRAM DDR2 800 (PC2 6400) Dual Channel Kit Desktop Memory Model F2-6400CL5D-4GBPQ Since its inception, the machine has periodically locked up, the regularity having varied over the years from once a day to once a month. Typically, lockups happen once every few days. By "lockup" I mean my computer just freezes. The screen locks up, I can't move the mouse. Hitting keys on my keyboard that normally turn LEDs on or off on the keyboard (such as Caps Lock) no longer turn the LEDs on or off. If there was music playing at the time of the lockup, noise keeps coming out of the speakers, but it's just the current frequency/note that plays indefinitely. There is no BSOD. When such a lockup occurs I have to do a hard reboot by either turning off the computer or hitting the reset button. I have the most recent version of the NVIDIA hardware drivers, and update them semi-regularly, but that hasn't seemed to help. I am currently using Windows 7 x64, but was previously using Windows Server 2003 x64 and having the same lockup issues. My guess is that it's somehow video driver or motherboard related, but I don't know how to go about diagnosing this problem to narrow down which of the two is the culprit. Additional information re: cooling Regarding cooling... I've not installed any after-market cooling systems aside from two regular fans I scavenged from an older computer. The fan atop the CPU is the one that shipped with it. One of the two scavenged fans I added it located at the bottom tower of the corner, in an attempt to create some airflow from front to back. The second fan is pointed directly at the two video cards. SpeedFan installation and readings Per studiohack's suggestion, I installed SpeedFan, which provided the following temperature readings: GPU: 63C GPU: 65C System: 76C CPU: 64C AUX: 36C Core 0: 78C Core 1: 76C Core 2: 79C Core 3: 79C Update #3: Another Lockup :-( Well, I had another lockup last night. :-( SpeedFan reported the CPU temp at 38 C when it happened, and there was no spike in temperature leading up to the freeze. One thing I notice is that the freeze seems more likely to happen if I am watching a video. In fact, of the last 5 freezes over the past month, 4 of them have been while watching a video on Flickr. Not necessarily the same video, but a video nevertheless. I don't know if this is just coincidence or if it means anything. (As an aside, each night before bedtime my 2 year old daughter sits on my lap and watches some home videos on Flickr and, in the last month, has learned the phrase, "Uh oh, computer broke.") Update #4: MemTest86 and 3DMark06 Test Results: Per suggestions in the comments, I ran the MemTest86 overnight and it cycled through the 8 GB of memory 5 times without error. I also ran the 3DMark06 test without a problem (see my scores at http://3dmark.com/3dm06/15163549). So... what now? :-) Any further suggestions on what to check? Is there some way to get a stack trace or something when the computer locks like that? Resolution I have never did figure out the particular problems, but based on the suggestions here and elsewhere, I'm presuming it was a motherboard issue. In any event, I recently upgraded my system, buying a new motherbeard, PSU, CPU, and RAM, and that new rig has been working splendidly the past several weeks. I am using the same graphic cards as in the old setup, so I think it's safe to reason that they weren't the cause of the problem.

    Read the article

  • How can I check if PHP was compiled with the UNICODE version of the Win32 API?

    - by Wesley Murch
    This is related to this Stack Overflow post: glob() can't find file names with multibyte characters on Windows? I'm having issues with PHP and files that have multibyte characters on Windows. Here's my test case: print_r(scandir('./uploads/')); print_r(glob('./uploads/*')); Correct Output on remote UNIX server: Array ( [0] => . [1] => .. [2] => filename-äöü.jpg [3] => filename.jpg [4] => test?test.jpg [5] => ??? ?????.jpg [6] => ?????????.jpg [7] => ???.jpg ) Array ( [0] => ./uploads/filename-äöü.jpg [1] => ./uploads/filename.jpg [2] => ./uploads/test?test.jpg [3] => ./uploads/??? ?????.jpg [4] => ./uploads/?????????.jpg [5] => ./uploads/???.jpg ) Incorrect Output locally on Windows: Array ( [0] => . [1] => .. [2] => ??? ?????.jpg [3] => ???.jpg [4] => ?????????.jpg [5] => filename-äöü.jpg [6] => filename.jpg [7] => test?test.jpg ) Array ( [0] => ./uploads/filename-äöü.jpg [1] => ./uploads/filename.jpg ) Here's a relevant excerpt from the answer I chose to accept (which actually is a quote from an article that was posted online over 2 years ago): From the comments on this article: http://www.rooftopsolutions.nl/blog/filesystem-encoding-and-php The output from your PHP installation on Windows is easy to explain : you installed the wrong version of PHP, and used a version not compiled to use the Unicode version of the Win32 API. For this reason, the filesystem calls used by PHP will use the legacy "ANSI" API and so the C/C++ libraries linked with this version of PHP will first try to convert yout UTF-8-encoded PHP string into the local "ANSI" codepage selected in the running environment (see the CHCP command before starting PHP from a command line window) Your version of Windows is MOST PROBABLY NOT responsible of this weird thing. Actually, this is YOUR version of PHP which is not compiled correctly, and that uses the legacy ANSI version of the Win32 API (for compatibility with the legacy 16-bit versions of Windows 95/98 whose filesystem support in the kernel actually had no direct support for Unicode, but used an internal conversion layer to convert Unicode to the local ANSI codepage before using the actual ANSI version of the API). Recompile PHP using the compiler option to use the UNICODE version of the Win32 API (which should be the default today, and anyway always the default for PHP installed on a server that will NEVER be Windows 95 or Windows 98...) I can't confirm whether this is my problem or not. I used phpinfo() and did not find anything interesting, but I wasn't sure what to look for. I've been using XAMPP for easy installations, so I'm really not sure exactly how it was installed. I'm using Windows 7, 64 bit - so forgive my ignorance, but I'm not even sure if "Win32" is relevant here. How can I check if my current version of PHP was compiled with the configuration mentioned above? PHP Version: 5.3.8 System: Windows NT WES-PC 6.1 build 7601 (Windows 7 Home Premium Edition Service Pack 1) i586 Build Date: Aug 23 2011 11:47:20 Compiler: MSVC9 (Visual C++ 2008) Architecture: x86 Configure Command: cscript /nologo configure.js "--enable-snapshot-build" "--disable-isapi" "--enable-debug-pack" "--disable-isapi" "--without-mssql" "--without-pdo-mssql" "--without-pi3web" "--with-pdo-oci=D:\php-sdk\oracle\instantclient10\sdk,shared" "--with-oci8=D:\php-sdk\oracle\instantclient10\sdk,shared" "--with-oci8-11g=D:\php-sdk\oracle\instantclient11\sdk,shared" "--enable-object-out-dir=../obj/" "--enable-com-dotnet" "--with-mcrypt=static" "--disable-static-analyze"

    Read the article

  • Parallel processing slower than sequential?

    - by zebediah49
    EDIT: For anyone who stumbles upon this in the future: Imagemagick uses a MP library. It's faster to use available cores if they're around, but if you have parallel jobs, it's unhelpful. Do one of the following: do your jobs serially (with Imagemagick in parallel mode) set MAGICK_THREAD_LIMIT=1 for your invocation of the imagemagick binary in question. By making Imagemagick use only one thread, it slows down by 20-30% in my test cases, but meant I could run one job per core without issues, for a significant net increase in performance. Original question: While converting some images using ImageMagick, I noticed a somewhat strange effect. Using xargs was significantly slower than a standard for loop. Since xargs limited to a single process should act like a for loop, I tested that, and found it to be about the same. Thus, we have this demonstration. Quad core (AMD Athalon X4, 2.6GHz) Working entirely on a tempfs (16g ram total; no swap) No other major loads Results: /media/ramdisk/img$ time for f in *.bmp; do echo $f ${f%bmp}png; done | xargs -n 2 -P 1 convert -auto-level real 0m3.784s user 0m2.240s sys 0m0.230s /media/ramdisk/img$ time for f in *.bmp; do echo $f ${f%bmp}png; done | xargs -n 2 -P 2 convert -auto-level real 0m9.097s user 0m28.020s sys 0m0.910s /media/ramdisk/img$ time for f in *.bmp; do echo $f ${f%bmp}png; done | xargs -n 2 -P 10 convert -auto-level real 0m9.844s user 0m33.200s sys 0m1.270s Can anyone think of a reason why running two instances of this program takes more than twice as long in real time, and more than ten times as long in processor time to complete the same task? After that initial hit, more processes do not seem to have as significant of an effect. I thought it might have to do with disk seeking, so I did that test entirely in ram. Could it have something to do with how Convert works, and having more than one copy at once means it cannot use processor cache as efficiently or something? EDIT: When done with 1000x 769KB files, performance is as expected. Interesting. /media/ramdisk/img$ time for f in *.bmp; do echo $f ${f%bmp}png; done | xargs -n 2 -P 1 convert -auto-level real 3m37.679s user 5m6.980s sys 0m6.340s /media/ramdisk/img$ time for f in *.bmp; do echo $f ${f%bmp}png; done | xargs -n 2 -P 1 convert -auto-level real 3m37.152s user 5m6.140s sys 0m6.530s /media/ramdisk/img$ time for f in *.bmp; do echo $f ${f%bmp}png; done | xargs -n 2 -P 2 convert -auto-level real 2m7.578s user 5m35.410s sys 0m6.050s /media/ramdisk/img$ time for f in *.bmp; do echo $f ${f%bmp}png; done | xargs -n 2 -P 4 convert -auto-level real 1m36.959s user 5m48.900s sys 0m6.350s /media/ramdisk/img$ time for f in *.bmp; do echo $f ${f%bmp}png; done | xargs -n 2 -P 10 convert -auto-level real 1m36.392s user 5m54.840s sys 0m5.650s

    Read the article

  • batch file to deploy files

    - by Martin Michalak
    hi I have created batch file which pulls info from *.txt file and deploy code from the source to destination: SET Source=%1 if exist %Source% ( ECHO Source for WEB exists ) else ( ECHO Wrong build%Source% doesn't exist GOTO Menu ) SET Server=%2 SET AppPool=%3 SET Destination=%4 SET Folder=%5 SET ENV=%6 SET AppName=%7 SET Envlog=%8 ECHO Deployment of WEB > %Envlog% %Date% %Time% echo. @ECHO Stopping App Pools @ECHO Stopping App Pools >> %Envlog% %Date% %Time% D:\ICTTools\PSEXEC.EXE -d \\%Server% cmd.exe /c c:\windows\system32\inetsrv\appcmd STOP apppool /apppool.name:%AppPool% echo. @ECHO App Pools will be stopped in the background @ECHO App Pools will be stopped in the background >> %Envlog% %Date% %Time% Pause echo. IF EXIST "%Destination%" ( ECHO Deleting %AppName% %Folder% RMDIR %Destination% /s /q ECHO Destination Folder %Folder% Deleted ECHO Destination Folder %Folder% Deleted >> %Envlog% %Date% %Time% ) else ( ECHO Destination Folder %Destination% does not exist, please check ECHO Destination Folder %Destination% does not exist, please check >> %Envlog% %Date% %Time% Pause ) echo. @ECHO Starting Robocopy for %AppName% @ECHO Starting Robocopy for %AppName% >> %Envlog% %Date% %Time% echo. START /WAIT /MIN ROBOCOPY.EXE %Source% %Destination% *.* /S /NP /R:3 /W:5 /LOG:"Logs\Robo%AppName%%ENV%.log" D:\Tools\Windiff\windiff.exe %Source% %Destination% echo. @ECHO Finished with Robocopy @ECHO Finished with Robocopy >> %Envlog% %Date% %Time% echo. @ECHO Checking if App pools stopped: @ECHO Checking if App pools stopped: >> %Envlog% %Date% %Time% D:\ICTTools\PSEXEC.EXE \\%Server% c:\windows\system32\inetsrv\appcmd LIST apppool /apppool.name:%AppPool% @echo off set /p ask=All app pools stopped? (y/n) if %ask%==y (echo Great, please continue with deployemnt) else echo Before continuing please check why app pools did not stop @echo App pools stopped?: %ask% >> %Envlog% %Date% %Time% DEL %Source%\web.config echo. @ECHO Production Config check if exist "%Destination%\%ENV%-Web.config" ( echo. ECHO The Application production configuration file does exist. ECHO The Application production configuration file does exist. >> %Envlog% %Date% %Time% COPY %Destination%\%ENV%-Web.config web.config echo. ECHO Production %ENV%-Web.config has been renamed to web.config ECHO Production %ENV%-Web.config has been renamed to web.config >> %Envlog% %Date% %Time% ) else ( ECHO The Application production configuration file is missing in Production %AppName% ECHO The Application production configuration file is missing in Production %AppName% >> %Envlog% %Date% %Time% explorer %Destination% Pause ) echo. @ECHO Confirm that configs were renamed correclty, if yes please hit any key to START APP Pools @ECHO Confirm that configs were renamed correclty, if yes please hit any key to START APP Pools >> %Envlog% %Date% %Time% Pause echo. @ECHO Start %AppName% Application Pool >> %Envlog% %Date% %Time% D:\ICTTools\PSEXEC.EXE \\%Server% c:\windows\system32\inetsrv\appcmd START apppool /apppool.name:%AppPool% @echo off set /p ask=All app pools started? (y/n) if %ask%==y (echo Great, please continue with deployemnt) else echo Before continuing please check why app pools did not start @echo App pools started?: %ask% >> %Envlog% %Date% %Time% Pause echo. @ECHO Build Version for %AppName% @ECHO Build Version for %AppName% >> %Envlog% %Date% %Time% type %Destination%\buildinfo.xml echo. ECHO ............................................... @ECHO ...........Deployment Compelted................ @ECHO ...........Deployment Compelted................>> %Envlog% %Date% %Time% ECHO ............................................... here are my issues: Lets say I am running code for 3 servers, then for each instance: For all three servers I am performing destination folder delete even so destination folder is always the same, the code should only delete it in the 1st instance (when code is deployed to first server) then I would prefer if script would check if the code from the source and destination is the same and if it is it should delete the folder or not. Then based on 1: a) deleting web.config and renaming should only happen if code in destination is new b) Robocopy should not override files if they are the same I think there is /Xo option to do that any idea how to achieve that? :)

    Read the article

  • BSOD Code 16, artifacts all over the place (gtx 260)

    - by belinea
    I have a following, quite dated rig E8400 Core 2 Duo cpu Intel Dragontail Peak DP35DP motherboard on Intel Bearlake P35 chipset 4GB ram Geforce 260gtx Corsair 650W PSU Windows 7 64 bit The following things has happened in the last few days. I first decided to update my Nvidia drivers to the latest version. That was 4 days ago. PC worked fine for 2 days and I was able to play few games as well without any problems. Then 2 days ago a first crash happened while playing the new XCOM game. BSOD code 16. Just the blue screen, no artifacts. PC rebooted and worked well again, I continued playing this game for another 2 hours and went to sleep. Next evening I tried to play some BF3 multiplayer (use to play on LOW settings). Approx. 10 minutes into the game red/pink-ish artifacts appeared on the screen and game quit to desktop. Restarted the game and another 3-4 minutes afterwards another crash to desktop but this time followed shortly by BSOD Code 16. From that moment I started to seeing artifacts on random startups, including Windows loading screen and the BIOS itself. Windows would still load but soon enough it would BSOD on a simple task like opening a Internet browser. Today I get tons of artifacts (little small red dashes all over the screen) on BIOS, loading screen, normal Windows mode as well as safe mode. I suspect it wouldn't be drivers but I tried removing and sweeping them entirely in the safe mode. PC would still start with artifacts all over the place but would load the normal mode, just without the driver, in the default lowest resolution. As soon as proper Nvidia drivers are installed though and PC rebooted, Windows doesn't load at all as BSOD now appears on loading screen. However, again, if I go to safe mode and remove drivers, normal mode launches fine. So obviously crash happens only on high resolution. I opened my machine this morning and gave it a proper cleaning even though it wasn't heavily dusted. It didn't help and number of artifacts seems to increase with every PC restart. I write these words in safe mode, which works, but I have to look through all the red dots and dashes. I don't have built in GPU chipset so I can't try removing my Geforce card nor can I borrow A GPU from anyone else. What are my options? I was looking into getting a completely new rig around Christmas so I'm not freaking out about this. If everything points to hardware issue I may simply decide to get the new machine earlier and don't bother with fixing this one. However it would be great to learn more if this is indeed situation that has slim chances of getting sorted. I realize BSOD Code 16 is rather popular topic online but every story seems a bit different and there can be number of issues with it. Hence a new thread.

    Read the article

  • Specifying a Postfix Instance to send outbound email

    - by Catherine Jefferson
    I have a CentOS 6.5 server running Postfix 2.6x (the default distribution) with five public IPv4 IPs bound to it. Each IP has DNS and rDNS set separately. Each uses a different hostname at a different domain. I have five Postfix instances, one bound to each IP, like this example: 192.168.34.104 red.example.com /etc/postfix 192.168.36.48 green.example.net /etc/postfix-green 192.168.36.49 pink.example.org /etc/postfix-pink 192.168.36.50 orange.example.info /etc/postfix-orange 192.168.36.51 blue.example.us /etc/postfix-blue I've tested each IP by telneting to port 25. Postfix answers and banners properly with the correct hostname. Email is received on all of these instances with no problems and is routed to the correct place. This setup, minus the final instance, has existed for a couple of years and works. I never bothered to set up outbound email to go through any but the main instance, however; there was no need. Now I need to send email from blue.example.us that actually leaves from that interface and IP, such that the Received headers show blue.example.us as the sending mailhost, so that SPF and DKIM validate, etc etc. The email that will be sent from blue.example.com is a feedback loop sent by a single shell account on the server (account5), an account that is dedicated to sending this email. The account receives the feedback loop emails from servers on other networks, saves the bodies of those emails, and then generates a new outbound email header, appends the saved body, and sends the email. It's sending by piping each email to sendmail -oi -t. We're doing it this way to mask the identities of the initial servers. The procmail script that processes these emails works correctly. However, I cannot configure this account to send email through the proper Postfix instance/IP/interface. The exact same account and script sends email through the main Postfix instance /etc/postfix without any issues. When I change MAIL_CONFIG to point to /etc/postfix-blue in either .bash_profile or the Procmail script that handles this email, though, I get this error: sendmail: fatal: User account5(###) is not allowed to submit mail I've read the manuals on Postfix.org, searched Google, and tried the suggestions in three previous answers here on ServerFault.com: Postfix - specify interface to deliver outbound mail on Postfix user is not allowed to submit mail Postfix rejects php mails I have been careful to stop and restart Postfix after each configuration change, and tested the results. Nothing has worked. The main postfix instance happily accepts outbound email from account5. The postfix-blue instance continues to reject email from account5 with the sendmail error above. As tempting as it is to blame machine hostility, I know that I must be missing something or doing something wrong. Does anybody have any suggestions as to what it might be? Please feel free to ask for further information about my setup if you need it. =-=-=-=-=-=-=-=-=-= At the request of the responder, here are main.cf and master.cf for a) the main postfix instance ("red.example.com") and b) the FBL instance ("blue.example.us") [NOTE: All parameters not specified below were left at the default Postfix 2.6 settings] MAIN: master.cf smtp inet n - n - - smtpd main.cf myhostname = red.example.com mydomain = example.com inet_interfaces = $myhostname, localhost inet_protocols = all lmtp_host_lookup = native smtp_host_lookup = native ignore_mx_lookup_error = yes mydestination = $myhostname, localhost.$mydomain, localhost local_recipient_maps = mynetworks = 192.168.34.104/32 relay_domains = example.com, example.info, example.net, example.org, example.us relayhost = [192.168.34.102] # Separate physical server, main mailserver. relay_recipient_maps = hash:/etc/postfix/relay_recipients alias_maps = hash:/etc/aliases alias_database = hash:/etc/aliases smtpd_banner = $myhostname ESMTP $mail_name multi_instance_wrapper = ${command_directory}/postmulti -p -- multi_instance_enable = yes multi_instance_directories = /etc/postfix-green /etc/postfix-pink /etc/postfix-orange /etc/postfix-blue FBL: master.cf 184.173.119.103:25 inet n - n - - smtpd main.cf myhostname = blue.example.us mydomain = blue.example.us <= Deliberately set to subdomain only. myorigin = $mydomain inet_interfaces = $myhostname lmtp_host_lookup = native smtp_host_lookup = native ignore_mx_lookup_error = yes mydestination = $myhostname local_recipient_maps = unix:passwd.byname $alias_maps $virtual_alias_maps mynetworks = 192.168.36.51/32, 192.168.35.20/31 <= Second IP is backup MX servers relay_domains = $mydestination recipient_canonical_maps = hash:/etc/postfix-blue/canonical virtual_alias_maps = hash:/etc/postfix-fbl/virtual alias_maps = hash:/etc/aliases, hash:/etc/postfix-blue/canonical alias_maps = hash:/etc/aliases, hash:/etc/postfix-blue/canonical mailbox_command = /usr/bin/procmail -a "$EXTENSION" DEFAULT=$HOME/Mail/ MAILDIR=$HOME/Mail smtpd_banner = $myhostname ESMTP $mail_name authorized_submit_users = multi_instance_name = postfix-blue multi_instance_enable = yes

    Read the article

< Previous Page | 408 409 410 411 412 413 414 415 416 417 418 419  | Next Page >