Search Results

Search found 38249 results on 1530 pages for 'visual studio test profes'.

Page 42/1530 | < Previous Page | 38 39 40 41 42 43 44 45 46 47 48 49  | Next Page >

  • Turning off Chrome's visual effects

    - by Wesley
    Is there any way to turn off the visual effects used by Google Chrome? For example, the tabs slide around smoothly, the scrolling is really smooth, and there is a huge arrow that fades in and out during download. Reason why I'd like to know is primarily because I want to maximize battery life on my netbook by using less visual effects and, secondly, because I use Chrome on slower systems and would like to maximize the performance and efficiency of Chrome. This applies mainly to Windows XP, but also Vista, 7 and even (X)Ubuntu 9.10. EDIT1: Oh yes... disabling the attaching/detaching of tabs and turning them into translucent in the process. That's a bit stressful on my slower machines.

    Read the article

  • Heap corruption error after language pack installation for Visual Studio 2012

    - by Lyndon
    I have installed the german version of Visual Studio 2012 Premium on my german windows machine and installed the english language pack vor Visual Studio 2012 Premium and it works great but after I installed the german language pack I get the heap corruption error 0xc0000374. The faulty module is ntdll.dll, version: 6.3.9600.16408 Only restoring Windows resolves this issue. Edit: This error also occurs when changing the displayed language and I was able to observe this behavior only after updating from Windows 8 to Windows 8.1 and updating from DevExpress 12.1 to DevExpress 13.1. Not only that, but the error does not occure immediately after installing a language, sometimes I can start debugging my program as usual and then after three to five times or so, the error occurs. Is there another solution than restoring Windows?

    Read the article

  • MASM Syntax Highlighting in C++ for Visual Studio 2010

    - by Ian Mallett
    So, I had Visual Studio 2010 Ultimate, and everything was great. However, I was confused, thought I wanted MASM, and installed the SDK. This causes strange problems for syntax highlighting. When I'm editing a C/C++ file, for instance, a lot of words (e.g., "data", "add", "sub", "mul", "div", "eax", etc.) are highlighted. At first, I thought I'd just learn to live with it, but it has gotten annoying. I could find nothing online, so, I deleted the MASM folder completely (method of uninstallation), uninstalled Visual Studio, and then installed it again. I firedit up, and the problem persists. Any clues? Thanks, Ian

    Read the article

  • Benchmarks relevant for a Visual Studio .Net development workstation

    - by user30715
    I am developing a system with Windows 7-64, Visual Studio and Sharepoint on a virtual workstation on some kind of VMWare server. The system is painfully slow, with VS lagging behind when entering code, Intellisense lagging, opening and saving files takes ages when compared to a normal budget laptop. As far as I can see the virtual machine has OK specs and does not seem to be swapping etc., and the IT dept also says that they can't see anything wrong when they're monitoring the system. As long as the problem is not well-documented, the IT dept and management does not want to throw money (=upgraded laptops) at us, so I need to show some sort of benchmark. It has been many years since I did any system benchmarking, and I don't know the current benchmark software, so my question is which benchmark will be most relevant for Visual Studio performance? Not just for compiling fast, but also to reflect the "responsiveness" of the system. Cheers, user30715

    Read the article

  • Visual Studio 2008/2010 Intellisense disable tab key

    - by Sean Edwards
    So I've been having problems with my left wrist and working on code for extended period of times, and I've pretty much narrowed the cause down to Intellisense autocomplete and the tab key. Ok, to be fair, I can't blame Intellisense, but constantly reaching over to hit that key is causing problems. I've discovered Enter does the exact same thing in that context, but that's not the key I instinctively reach for. Is it possible to outright disable the function of the tab key in intellisense, so I'm forced to use Enter instead (which I hit without contorting my wrist oddly.) Thanks. P.S. I do have Visual Assist, so if it's not possible in Visual Studio itself, can VAssistX help?

    Read the article

  • .NET Framework 4.0 Targeting Pack does not show in Visual Studio

    - by balexandre
    How can I install the .NET 4.0 Framework on Windows 8 Pro / Visual Studio 2012 Professional? I get this: and if I follow the link of Install other frameworks... I get into Microsoft page where I find this information: I have then installed .NET Framework 4.0.1 Targeting Pack and .NET Framework 4.0.2 Targeting Pack as I can't install 4.0.3, restarted the machine over an over, but Visual Studio continues not to show the framework on the dropdown menu. What am I doing wrong? Here is what regedit says what I have installed on my machine:

    Read the article

  • Laptops and Visual Studio 2010

    - by Chad
    I have three days to get a new laptop before I need one that can run Visual Studio 2010. Normally I have two instances open, an instance of SQL Management studio, IIS, and a few web browsers. Who develops regularly on one, what are the specs I should look at targeting? I haven't bought a laptop in 5 years, so I'm way out of touch with where they are at as far as specs go. Thanks. ps. Budget isn't a huge concern, but I'm trying to keep it reasonable.

    Read the article

  • Synergy Locks up w7 when Visual Studio is debugging

    - by EdK
    I love synergy but as a developer this is driving me crazy. I use Synergy to go through two x64 Windows 7 machines (with all flavors of Visual studio from 2003 to 2010 professional) and an MacOS 10.6? desktop and most of the time it works flawlessly. However, if I happen to be in the middle of a transition from one windows 7 machine to the other (it's never happened to the mac but I don't flip to it that often) when Visual Studio hits a breakpoint, the mouse and keyboard both completely lock up and the only way I can seem to do anything is to physically unplug the mouse and keyboard and plug them back in. Unfortunately I have to crawl under my desk to do that, so you can see where it'd be annoying. Anybody have any idea how I can get around this? I did note that it was much more frequent with the previous version I had of synergy+ before I upgraded/sidegraded to the current version of synergy. But it's still happening. Thanks alot,

    Read the article

  • Unable to install visual studio 2012 on windows 7

    - by Nirvan
    I was attempting to install Visual Studio 2012 Express Version on windows 7, but got the following error. The error talks about some Interop Assem, which I believe is related to Microsoft Office. I tried to install the Interop Assem, but it seems that they cannot be installed for Starter Versions of the Microsoft Office. So, how do I go about installing Visual Studio 2012 on my Windows 7 machine, without full version of Microsoft Office installed, Or the error is related to something else. Update: I have tried to install the following Interop Assem but the installation terminates without any status.

    Read the article

  • What should i expect on an online C++ test

    - by Craig
    Hey guys, I don't know if this should be a regular question or maybe a wiki page. I just got a call back from an employer and he advised me i have made it through to the next round of interviews and would have to take an online C++ test through IKM (http://www.ikmnet.com/). Has anyone here got any advise as to what type of questions this test will ask, or has anyone got advise about what i should do a brush up on to do the best i could on this test. THis is for a job in simulations if that helps at all, Any advise would be great. -Craig

    Read the article

  • How to prepare for a Java test?

    - by Zenzen
    Ok so in two days I have a test for my dream job (well it's an internship, but still!) and for quite some time now I've been reading the SCJP Guide book in order to prepare myself. BUT seeing how slow my reading speed is I guess finding a website with some "java essentials" or "standard java test questions" and going through it in those 2 days would be a better idea. Don't misunderstand me, I do have java experience and it's "only" an internship, but we all know how programming tests look like and how tricky they can be. So are there any online resources you could recommend me? I know 2 days is not much, but well I was informed bout the test 1-2days ago.

    Read the article

  • Test, if object was deleted

    - by justik
    Look to the following code, please: class Node { private: double x, y; public: Node (double xx, double yy): x(xx), y(yy){} }; int main() { Node *n1 = new Node(1,1); Node *n2 = n1; delete n2; n2 = NULL; if (n1 != NULL) //Bad test { delete n1; //throw an exception } } There are two pointers n1, n2 pointed to the same object. I would like to detect whether n2 was deleted using n1 pointer test. But this test results in exception. Is there any way how to determine whether the object was deleted (or was not deleted) using n1 pointer ? Thanks for your help.

    Read the article

  • Could You Quickly Test a Web Page in Apples Safari 3 [Simple Pass:Fail]

    - by Jay
    I am not fortunate to have access to Apple Safari 3.0 [which has a WebKit version < 525]. Would someone kindly test a Web page for me, it will return your userAgent string and a simple pass:fail. In WebKit versions < 525.… [<= Apple Safari 3.0] it should fail and = 525.… [= Apple Safari 3.1] it should pass. I appreciate all your help, all you have to post is if the Web page, on the second line, says pass or fail, please. Kind regards! To test: http://80etc.com/test.html

    Read the article

  • JUnit 4 test suite problems

    - by Hypnus
    Hi, i have a problem with some JUnit 4 tests that i run with a test suite. If i run the tests individually they work with no problems but when run in a suite most of them, 90% of the test methods, fail with errors. What i noticed is that always the first tests works fine but the rest are failing. Another thing is that a few of the tests the methods are not executed in the right order (the reflection does not work as aspected - or it does because the retrieval of the methods is not necessarily in the created order). This usually happens if there is more than one test with methods that have the same name. I tried to debug some of the tests and it seems that from a line to the next the value of some attributes gets null. Does anyone know what is the problem, or if the behavior is "normal"? Thanks in advance.

    Read the article

  • boost test case for function taking user input

    - by oadams
    I have a function that takes in user input via std::cin: std::getline(std::cin, in); and creates a corresponding data structure by matching it with a regular expression. The function then returns this data structure. I'm using boost.test and I want to create a unit test to check that the output data type is correct given some inputs. However I don't know how to go about it since the input isn't passed as an argument to the function. EDIT: Is there a simple way to create a boost test case that feeds the function a string via standard input?

    Read the article

  • An easy way to create Side by Side registrationless COM Manifests with Visual Studio

    - by Rick Strahl
    Here's something I didn't find out until today: You can use Visual Studio to easily create registrationless COM manifest files for you with just a couple of small steps. Registrationless COM lets you use COM component without them being registered in the registry. This means it's possible to deploy COM components along with another application using plain xcopy semantics. To be sure it's rarely quite that easy - you need to watch out for dependencies - but if you know you have COM components that are light weight and have no or known dependencies it's easy to get everything into a single folder and off you go. Registrationless COM works via manifest files which carry the same name as the executable plus a .manifest extension (ie. yourapp.exe.manifest) I'm going to use a Visual FoxPro COM object as an example and create a simple Windows Forms app that calls the component - without that component being registered. Let's take a walk down memory lane… Create a COM Component I start by creating a FoxPro COM component because that's what I know and am working with here in my legacy environment. You can use VB classic or C++ ATL object if that's more to your liking. Here's a real simple Fox one: DEFINE CLASS SimpleServer as Session OLEPUBLIC FUNCTION HelloWorld(lcName) RETURN "Hello " + lcName ENDDEFINE Compile it into a DLL COM component with: BUILD MTDLL simpleserver FROM simpleserver RECOMPILE And to make sure it works test it quickly from Visual FoxPro: server = CREATEOBJECT("simpleServer.simpleserver") MESSAGEBOX( server.HelloWorld("Rick") ) Using Visual Studio to create a Manifest File for a COM Component Next open Visual Studio and create a new executable project - a Console App or WinForms or WPF application will all do. Go to the References Node Select Add Reference Use the Browse tab and find your compiled DLL to import  Next you'll see your assembly in the project. Right click on the reference and select Properties Click on the Isolated DropDown and select True Compile and that's all there's to it. Visual Studio will create a App.exe.manifest file right alongside your application's EXE. The manifest file created looks like this: xml version="1.0" encoding="utf-8"? assembly xsi:schemaLocation="urn:schemas-microsoft-com:asm.v1 assembly.adaptive.xsd" manifestVersion="1.0" xmlns:asmv1="urn:schemas-microsoft-com:asm.v1" xmlns:asmv2="urn:schemas-microsoft-com:asm.v2" xmlns:asmv3="urn:schemas-microsoft-com:asm.v3" xmlns:dsig="http://www.w3.org/2000/09/xmldsig#" xmlns:co.v1="urn:schemas-microsoft-com:clickonce.v1" xmlns:co.v2="urn:schemas-microsoft-com:clickonce.v2" xmlns="urn:schemas-microsoft-com:asm.v1" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" assemblyIdentity name="App.exe" version="1.0.0.0" processorArchitecture="x86" type="win32" / file name="simpleserver.DLL" asmv2:size="27293" hash xmlns="urn:schemas-microsoft-com:asm.v2" dsig:Transforms dsig:Transform Algorithm="urn:schemas-microsoft-com:HashTransforms.Identity" / dsig:Transforms dsig:DigestMethod Algorithm="http://www.w3.org/2000/09/xmldsig#sha1" / dsig:DigestValuepuq+ua20bbidGOWhPOxfquztBCU=dsig:DigestValue hash typelib tlbid="{f10346e2-c9d9-47f7-81d1-74059cc15c3c}" version="1.0" helpdir="" resourceid="0" flags="HASDISKIMAGE" / comClass clsid="{af2c2811-0657-4264-a1f5-06d033a969ff}" threadingModel="Apartment" tlbid="{f10346e2-c9d9-47f7-81d1-74059cc15c3c}" progid="simpleserver.SimpleServer" description="simpleserver.SimpleServer" / file assembly Now let's finish our super complex console app to test with: using System; using System.Collections.Generic; using System.Text; namespace ConsoleApplication1 {     class Program     {         static voidMain(string[] args)         { Type type = Type.GetTypeFromProgID("simpleserver.simpleserver",true); dynamic server = Activator.CreateInstance(type); Console.WriteLine(server.HelloWorld("rick")); Console.ReadLine(); } } } Now run the Console Application… As expected that should work. And why not? The COM component is still registered, right? :-) Nothing tricky about that. Let's unregister the COM component and then re-run and see what happens. Go to the Command Prompt Change to the folder where the DLL is installed Unregister with: RegSvr32 -u simpleserver.dll      To be sure that the COM component no longer works, check it out with the same test you used earlier (ie. o = CREATEOBJECT("SimpleServer.SimpleServer") in your development environment or VBScript etc.). Make sure you run the EXE and you don't re-compile the application or else Visual Studio will complain that it can't find the COM component in the registry while compiling. In fact now that we have our .manifest file you can remove the COM object from the project. When you run run the EXE from Windows Explorer or a command prompt to avoid the recompile. Watch out for embedded Manifest Files Now recompile your .NET project and run it… and it will most likely fail! The problem is that .NET applications by default embeds a manifest file into the compiled EXE application which results in the externally created manifest file being completely ignored. Only one manifest can be applied at a time and the compiled manifest takes precedency. Uh, thanks Visual Studio - not very helpful… Note that if you use another development tool like Visual FoxPro to create your EXE this won't be an issue as long as the tool doesn't automatically add a manifest file. Creating a Visual FoxPro EXE for example will work immediately with the generated manifest file as is. If you are using .NET and Visual Studio you have a couple of options of getting around this: Remove the embedded manifest file Copy the contents of the generated manifest file into a project manifest file and compile that in To remove an embedded manifest in a Visual Studio project: Open the Project Properties (Alt-Enter on project node) Go down to Resources | Manifest and select | Create Application without a Manifest   You can now add use the external manifest file and it will actually be respected when the app runs. The other option is to let Visual Studio create the manifest file on disk and then explicitly add the manifest file into the project. Notice on the dialog above I did this for app.exe.manifest and the manifest actually shows up in the list. If I select this file it will be compiled into the EXE and be used in lieu of any external files and that works as well. Remove the simpleserver.dll reference so you can compile your code and run the application. Now it should work without COM registration of the component. Personally I prefer external manifests because they can be modified after the fact - compiled manifests are evil in my mind because they are immutable - once they are there they can't be overriden or changed. So I prefer an external manifest. However, if you are absolutely sure nothing needs to change and you don't want anybody messing with your manifest, you can also embed it. The option to either is there. Watch for Manifest Caching While working trying to get this to work I ran into some problems at first. Specifically when it wasn't working at first (due to the embedded schema) I played with various different manifest layouts in different files etc.. There are a number of different ways to actually represent manifest files including offloading to separate folder (more on that later). A few times I made deliberate errors in the schema file and I found that regardless of what I did once the app failed or worked no amount of changing of the manifest file would make it behave differently. It appears that Windows is caching the manifest data for a given EXE or DLL. It takes a restart or a recompile of either the EXE or the DLL to clear the caching. Recompile your servers in order to see manifest changes unless there's an outright failure of an invalid manifest file. If the app starts the manifest is being read and caches immediately. This can be very confusing especially if you don't know that it's happening. I found myself always recompiling the exe after each run and before making any changes to the manifest file. Don't forget about Runtimes of COM Objects In the example I used above I used a Visual FoxPro COM component. Visual FoxPro is a runtime based environment so if I'm going to distribute an application that uses a FoxPro COM object the runtimes need to be distributed as well. The same is true of classic Visual Basic applications. Assuming that you don't know whether the runtimes are installed on the target machines make sure to install all the additional files in the EXE's directory alongside the COM DLL. In the case of Visual FoxPro the target folder should contain: The EXE  App.exe The Manifest file (unless it's compiled in) App.exe.manifest The COM object DLL (simpleserver.dll) Visual FoxPro Runtimes: VFP9t.dll (or VFP9r.dll for non-multithreaded dlls), vfp9rENU.dll, msvcr71.dll All these files should be in the same folder. Debugging Manifest load Errors If you for some reason get your manifest loading wrong there are a couple of useful tools available - SxSTrace and SxSParse. These two tools can be a huge help in debugging manifest loading errors. Put the following into a batch file (SxS_Trace.bat for example): sxstrace Trace -logfile:sxs.bin sxstrace Parse -logfile:sxs.bin -outfile:sxs.txt Then start the batch file before running your EXE. Make sure there's no caching happening as described in the previous section. For example, if I go into the manifest file and explicitly break the CLSID and/or ProgID I get a detailed report on where the EXE is looking for the manifest and what it's reading. Eventually the trace gives me an error like this: INFO: Parsing Manifest File C:\wwapps\Conf\SideBySide\Code\app.EXE.     INFO: Manifest Definition Identity is App.exe,processorArchitecture="x86",type="win32",version="1.0.0.0".     ERROR: Line 13: The value {AAaf2c2811-0657-4264-a1f5-06d033a969ff} of attribute clsid in element comClass is invalid. ERROR: Activation Context generation failed. End Activation Context Generation. pinpointing nicely where the error lies. Pay special attention to the various attributes - they have to match exactly in the different sections of the manifest file(s). Multiple COM Objects The manifest file that Visual Studio creates is actually quite more complex than is required for basic registrationless COM object invokation. The manifest file can be simplified a lot actually by stripping off various namespaces and removing the type library references altogether. Here's an example of a simplified manifest file that actually includes references to 2 COM servers: xml version="1.0" encoding="utf-8"? assembly xmlns="urn:schemas-microsoft-com:asm.v1" manifestVersion="1.0" assemblyIdentity name="App.exe" version="1.0.0.0" processorArchitecture="x86" type="win32" / file name="simpleserver.DLL" comClass clsid="{af2c2811-0657-4264-a1f5-06d033a969ff}" threadingModel="Apartment" progid="simpleserver.SimpleServer" description="simpleserver.SimpleServer" / file file name = "sidebysidedeploy.dll" comClass clsid="{EF82B819-7963-4C36-9443-3978CD94F57C}" progid="sidebysidedeploy.SidebysidedeployServer" description="SidebySideDeploy Server" threadingModel="apartment" / file assembly Simple enough right? Routing to separate Manifest Files and Folders In the examples above all files ended up in the application's root folder - all the DLLs, support files and runtimes. Sometimes that's not so desirable and you can actually create separate manifest files. The easiest way to do this is to create a manifest file that 'routes' to another manifest file in a separate folder. Basically you create a new 'assembly identity' via a named id. You can then create a folder and another manifest with the id plus .manifest that points at the actual file. In this example I create: App.exe.manifest A folder called App.deploy A manifest file in App.deploy All DLLs and runtimes in App.deploy Let's start with that master manifest file. This file only holds a reference to another manifest file: App.exe.manifest xml version="1.0" encoding="UTF-8" standalone="yes"? assembly xmlns="urn:schemas-microsoft-com:asm.v1" manifestVersion="1.0" assemblyIdentity name="App.exe" version="1.0.0.0" processorArchitecture="x86" type="win32" / dependency dependentAssembly assemblyIdentity name="App.deploy" version="1.0.0.0" type="win32" / dependentAssembly dependency assembly   Note this file only contains a dependency to App.deploy which is another manifest id. I can then create App.deploy.manifest in the current folder or in an App.deploy folder. In this case I'll create App.deploy and in it copy the DLLs and support runtimes. I then create App.deploy.manifest. App.deploy.manifest xml version="1.0" encoding="UTF-8" standalone="yes"? assembly xmlns="urn:schemas-microsoft-com:asm.v1" manifestVersion="1.0" assemblyIdentity name="App.deploy" type="win32" version="1.0.0.0" / file name="simpleserver.DLL" comClass clsid="{af2c2811-0657-4264-a1f5-06d033a969ff}" threadingModel="Apartment" progid="simpleserver.SimpleServer" description="simpleserver.SimpleServer" / file file name="sidebysidedeploy.dll" comClass clsid="{EF82B819-7963-4C36-9443-3978CD94F57C}" threadingModel="Apartment" progid="sidebysidedeploy.SidebysidedeployServer" description="SidebySideDeploy Server" / file assembly   In this manifest file I then host my COM DLLs and any support runtimes. This is quite useful if you have lots of DLLs you are referencing or if you need to have separate configuration and application files that are associated with the COM object. This way the operation of your main application and the COM objects it interacts with is somewhat separated. You can see the two folders here:   Routing Manifests to different Folders In theory registrationless COM should be pretty easy in painless - you've seen the configuration manifest files and it certainly doesn't look very complicated, right? But the devil's in the details. The ActivationContext API (SxS - side by side activation) is very intolerant of small errors in the XML or formatting of the keys, so be really careful when setting up components, especially if you are manually editing these files. If you do run into trouble SxsTrace/SxsParse are a huge help to track down the problems. And remember that if you do have problems that you'll need to recompile your EXEs or DLLs for the SxS APIs to refresh themselves properly. All of this gets even more fun if you want to do registrationless COM inside of IIS :-) But I'll leave that for another blog post…© Rick Strahl, West Wind Technologies, 2005-2011Posted in COM  .NET  FoxPro   Tweet (function() { var po = document.createElement('script'); po.type = 'text/javascript'; po.async = true; po.src = 'https://apis.google.com/js/plusone.js'; var s = document.getElementsByTagName('script')[0]; s.parentNode.insertBefore(po, s); })();

    Read the article

  • Integrate QT and OpenCV in Visual Studio

    - by user2891190
    Sorry If you feel that this is an already asked question. But I googled for more than 2 days any tried lots of solution which given through stackoverflow and referred lots of tutorials. But I couldn't get a proper idea. I am already working in a project which use c++(visual studio) with opencv which I am developing as my university project. I have developing this for last 2 months. But now I want to add a better UI.(Previously I considered only on the functionality) So I decided to move into QT. I'm new to QT. So I did some google search. I know that I can do this with the QT creator. But I want to do this in visual studio as the functionality of my project is bit complex. What I already know is I have to build opencv with Qt using cmake. I followed few tutorials. But most of the tutorials use mingw and QT creator. http://www.anlak.com/build-debug-opencv-vs2010/ Accoring to above tutorial I generated a visual studio project using cmake. But when I tried to open that solution file my visual studio becomes not-responding. I can't figure out the reason. I tried two days and I couldn't find a proper tutorial which describes integration of QT and opencv in visual studio. So can someone give me the instruction to integrate QT and Opencv in visual studio.

    Read the article

  • Can my ikmnet test results say something about career choice I should take?

    - by Nicke
    I took 2 tests via ikmnet and scored 70 % on SQL and 65 % on Java. While not bad, it can be improved. The subskills I need to improve according to the test are interfaces and inheritance, compilation and deployment, flow control, The java.lang package and "Java Program Construction" and these topics seems rather broad to me. Rather than just learning by programming, could you advice me to take a certification, follow a course or otherwise improve my skills? By the way, I enjoy python more than Java so should I market myself more of a python programmer or even a role that some companies search for which seems like a system developer with more technical writing where the title is system analysts (evaluating systems in cooperation with management rather than programming.) Thank you for any comment and/or answer.

    Read the article

  • Should the Joel Test be essential for every software company? [closed]

    - by Mahbubur R Aaman
    Joel Test has 12 steps for better code. They are: Do you use source control? Can you make a build in one step? Do you make daily builds? Do you have a bug database? Do you fix bugs before writing new code? Do you have an up-to-date schedule? Do you have a spec? Do programmers have quiet working conditions? Do you use the best tools money can buy? Do you have testers? Do new candidates write code during their interview? Do you do hallway usability testing? Should these steps mandatory for every software companies? While recruiting programmers, then programmers should ask the company, as they follow joel steps?

    Read the article

  • Can an agile shop every really score 12 on the Joel Test?

    - by Simon
    I really like the Joel test, use it myself, and encourage my staff and interviewees to consider it carefully. However I don't think I can ever score more than 9 because a few points seem to contradict the Agile Manifesto, XP and TDD, which are the bedrocks of my world. Specifically the questions about schedule, specs, testers and quiet working conditions run counter to what we are trying to create and the values that we have adopted in being genuinely agile. So my question is whether it is possible for a true Agile shop to score 12?

    Read the article

  • Test run errors with MSTest in VS2010

    - by Tomas Lycken
    When I run my Unit Tests, all tests pass, but instead of "Test run succeeded" or whatever the success message is, I get "Test run error" in the little bar that tells me how many of my tests pass, even though all my tests passed. When i click the text, I'm taken to a page that tells me the following two things happened: Warning: conflict during test run deployment: deployment item '[...]\Booking.Web.dll' directly or indirectly referenced by the test container [...]\Booking.Web.Tests.dll cannot be deployed to 'Booking.Web.dll' because otherwise the file '[...]\Booking.Web.dll' would override deployment item '[...]\Booking.Web.dll' directly or indirectly referenced by '[...]\Booking.Web.Tests.dll' Error: Cannot initialize the ASP.NET project 'Booking.Web' Exception was thrown: The website could not be configured correctly; getting ASP.NET proccess information failed. Requesting 'http://localhost:54131/VSEnterpriseHelper.axd' returned an error: The remote server returned an error: (500) Internal Server Error. I don't understand half of what it's complaining about. How do I get rid of these errors? (And for reference: Booking.Web is an ASP.NET MVC 2 project, Booking.Web.Tests is a Test project, [...] is the full local path to the projects in my environment, in most of the cases above to the /bin/debug/ folder inside the Booking.Web project)

    Read the article

  • Running JUnit test classes from another JUnit test class

    - by Dr. Monkey
    I have two classes that I am testing (let's call them ClassA and ClassB). Each has its own JUnit test class (testClassA and testClassB respectively). ClassA relies on ClassB for its normal functioning, so I want to make sure ClassB passes its tests before running testClassA (otherwise the results from testClassA would be meaningless). What is the best way to do this? In this case it is for an assignment so I need to keep it to the two specified test classes if possible. Can/should I throw an exception from testClassA if testClassB's tests aren't all passed? This would require testClassB to run invisibly and just report its success/failure to testClassA, rather than to the GUI (via JUnit). I am using Eclipse and JUnit 4.8.1

    Read the article

  • Visual Studio Wcf Test Client - entering an Int array

    - by WebDude
    Hi, I've found the Visual Studio WCF test client quite useful when it comes to a quick test of my WCF service. This is the test client found in this location relative to your Visual Studio install directory: \Common7\IDE\WcfTestClient.exe I have a few service calls that require a parameter of type System.Int32[] I can't seem to figure out what values to enter against for this parameter as i keep receiving the error '[value entered]' is not a valid value for this type Trying to enter the value 27 i have tried the following, but all fails 27 { 27 } new System.Int32[] { 27 } Can anyone please help with how to do this

    Read the article

  • c# Unit Test: Writing to Settings in unit test does not save values in user.config

    - by HorstWalter
    I am running a c# unit test (VS 2008). Within the test I do write to the settings, which should result in saving the data to the user.config. Settings.Default.X = "History"; // X is string Settings.Default.Save(); But this simply does not create the file (I have crosschecked under "C:\Documents and Settings\HW\Local Settings\Application Data"). If I create the same stuff as a Console application, there is no problem persisting the data (same code). Is there something special I need to consider doing this in a UnitTest?

    Read the article

< Previous Page | 38 39 40 41 42 43 44 45 46 47 48 49  | Next Page >