Search Results

Search found 2490 results on 100 pages for 'hp uft'.

Page 43/100 | < Previous Page | 39 40 41 42 43 44 45 46 47 48 49 50  | Next Page >

  • How to shrink Windows 7 boot partition with unmovable files.

    - by Alex Che
    I have just bought HP laptop with Windows 7 (64 bit). It has 500 GB HDD with three partitions: small hidden system partition, 12 GiB HP recovery partition, and 450 GiB C: boot partition. I would like to split this large C: partition into two partitions, leaving only 100 GiB for system, and giving the rest to new data partition. Although Windows built-in Disk Management utility has an option to shrink the bootable partition, it only allows me to shrink it roughly by half, even though only 20 GiB on the partition is used. As far as I understand, system unmovable files lie in the middle of the partition, preventing Disk Management utility to do what I want. And since new HP laptops don't come with OS installation disks (they only allow you to create recovery disks youself), I can't just repartition HDD and then reinstall OS. So, is there any way to shrink C: bootable partition and preserve Windows 7 working? P.S.: I have tried to use 3rd party GParted utility, and after shrinking the partition Windows 7 stopped booting with BSOD. System recovery didn't work, and I had to do factory recover. Since this is a long process, I would like to avoid doing it again :) So, please, suggest only proven solutions.

    Read the article

  • OpenSolaris / Nexenta problems with NetXen 4-port NIC card (ntxn driver)

    - by ewwhite
    Hello, I'm running NexentaStor Enterprise on an HP ProLiant DL180 G6 server. The onboard NIC interfaces surface as igb0 and igb1 and work well. However, I've added an HP NC375T 4-port network card using the NetXen 3031 chipset. This card should be handled by the ntxn driver in the SUNWntxn package, but that results in "ntxn0: failed to map doorbell" messages upon boot. The network interfaces don't show up. After some research, I found HP's driver package for the card. The release notes for the driver package state: This version of the Driver is supported only on Oracle Solaris 10 5/09 & 10/09. Oracle Solaris 10 5/09 & 10/09 contain an older version of NetXen P3 driver package called SUNWntxn. So, adding another version of NetXen P3 driver package using pkgadd command might result in conflicts with the NetXen driver binary & related files. Users are advised to uninstall native SUNWntxn driver package before installing the new package. The install completes, but I end up with a different set of errors in initializing the card. ifconfig ntxn0 plumb ifconfig: cannot open link "ntxn0": DLPI link does not exist dmesg output: Jan 29 07:20:17 ch-san2 ntxn: [ID 977263 kern.warning] WARNING: Memory not available Jan 29 07:20:17 ch-san2 ntxn: [ID 404858 kern.notice] NOTICE: ntxn0: Mac registration error Trying to manually create the device files: root@ch-san2:/volumes# add_drv -i "4040,100" ntxn ("ntxn") already in use as a driver or alias. Update the driver: root@ch-san2:/volumes# update_drv -f ntxn devfsadm: driver failed to attach: ntxn Warning: Driver (ntxn) successfully added to system but failed to attach Any ideas on how to get this driver working, or should I ditch the card and go with an Intel or something else?

    Read the article

  • postfix Mail filters not running behind a controlled enviornment

    - by Ashish
    Hi, I have deployed a postfix server for email receiving. On this I have configured SenderID + SPF milter, by referring to http://www.postfix.org/MILTER_README.html The command that I used is as follows: ./sid-filter -u postfix -p inet:10027@localhost -l Following are my settings in main.cf file: #Milter support for smtpd mail smtpd_milters = inet:localhost:10027, inet:localhost:10028 # Milters for non-SMTP mail. non_smtpd_milters = inet:localhost:10027, inet:localhost:10028 milter_default_action = reject # Postfix . 2.6 #milter_protocol = 6 # 2.3 . Postfix . 2.5 milter_protocol = 2 Now I have this observation: One of the postfix that is setup on AWS CentOS 5.5 is working fine and is able to receive mails on defined mx record. One of the similar postfix(as in step 1) that is setup behind one of the corporate firewalls is not able to receive any mails and is giving following type of error logs: connect from xxxxxx.austin.hp.com[xx.xxx.96.198] May 25 13:20:02 g2t0385g postfix/smtpd[11733]: C11F9B0194: client=xxxxxxx.austin.hp.com[15.217.96.198] May 25 13:20:03 g2t0385g postfix/cleanup[11814]: C11F9B0194: message-id= May 25 13:20:03 g2t0385g postfix/cleanup[11814]: C11F9B0194: milter-reject: END-OF-MESSAGE from xxxxxx.austin.hp.com[xx.xxx.96.198]: 5.7.1 Command rejected; from= to= proto=ESMTP helo= Here the 'sid-filter' is giving problems. Any idea, what I am doing wrong? Please help. Thanks in advance Ashish Sharma

    Read the article

  • Unable to boot with Windows 2008 DVD / USB Key

    - by r0ca
    Hi everyone, I am trying to install Windows 2008 server on a HP Proliant DL180 G5. There is no built-in DVD reader so I need to use my LaCie USB one. When I put the CD in and boot from the USB DVD on the server, I get the error message: Boot Failed! Please insert boot media in selected boot device. So I tried with another Windows bootable CD and still no luck. What I've done then, I copied the installation DVD on my 16go USB key. Again, impossible to boot from the USB Key. I have 2 147go SAS 15k HDD on my server. They are not showing in the Bios. I was wondering if this is a reason why nothing will boot on it. I am trying to find a way to deploy Windows 2008 server on my HP server as soon as possible. If you guys have ideas, feel free to let me know :) Best regards, David. System Information: HP Proliant DL180 G5 Quad-Core 2.5 4GO Ram 2x 147GO SAS 15k P.S. This is my first installation ever on SAS/SCSI HDD. Thanks a bunch! Edit: Well, my bad! I purchased a new USB DVD and now I can install Windows 2008 server. Thanks a bunch for your help!

    Read the article

  • Choosing a new laptop

    - by chiongms
    I'm looking for a new laptop. I saw few: i) HP ProBook 4321s ii) HP ProBook 6440b iii)Dell Latitude E6410 i found these laptops are still very new..is it? not much comments about them. can anyone help? i doubt how their graphic cards perform compare to each other? ProBook 4321s- Radeon HD4350 ProBook 6440b- Radeon HD4550 Latitude E6410- NVS 3100M most of the time i'll running 3D CAD software, C++ programing...i saw my friend's laptop with radeon HD4350. it's perfectly fulfilling my demand. but i wonder how the other two are? Another thing i doubt is the screen resolution..my current laptop is 1280x800, and i found it comfortable to use. But these two HP only offer 1366x768..will it make any large different? Lastly, is there anyway to estimate how their power consumption is from the spec sheet? well, i would prefer one with longer battery usage time. my current laptop is suck...only last 1 hour even when it's still new..i'm not going to get another like this anymore. Anyone can help me please? Thanks!

    Read the article

  • Virtual Fileserver

    - by Sergei
    Hi, We are planning to move our production servers to the datacenter and virtualize remaining servers in the process.Datacenter will have HP blades with vSphere on top.Currentliy we are using Celerra NS20 as fileserver.Since datacenter is using HP kit and EVA 4400 as SAN, we cannot have Celerra there, as EMC supoprt for Celerra does not work for non EMC array. I have searched for possible options and one of them was to have HP NAS blade X3800sb instead of Celerra.However this seems like overkill for me.We are only using Celerra for about 100 users and 50 servers and I think having X3800sb could be waste of resources. The other option would be to have a virtual fileserver as a part of vmware environment in datacenter.We only need CIFS to be provided.The only option I can think of is Windows Storage server.We had a bad expirience with Windows servers used as fileservers ( memory leaks one thing) in the past and this was one of the reasons we moved to Celerra. What are the other options?We need something as reliable as Celerra with as many options as possible.For example , Celerra has per folder quotas, deduplication, dynamic volume allocation, automatic failover, VTLU, replication. Also we would need to replicate NAS data to the failover site.We could use block level replication , SAN-to-SAN, but this would mean wasted bandwidth, as we need only subset of folders to be replicated.We used CA XSoft for windows servers in the past and Celerra has option for Celerra replication. Thank you very much in advance, Please ask me if I missed any details!

    Read the article

  • ESX hosts lose connectivity with iSCSI SAN LUNs

    - by Themist
    I've been experiencing this issue for a couple of months now where my ESX hosts lose connectivity with my iSCSI SAN vmfs volumes. As a results the ESX hosts enter a nonresponsive mode the associated VMs disconnect and the only remedy is to reboot the host. This issue happens randomly . I have escalated this issue with VMWare but I haven't had any solution to the issue yet. I see no errors on my switches and there are no hardware issues as well. My SAN infrastucture is solid and there are 2 paths for every vmfs volume. Did anybody else experienced a similar issue? edit: Here are some more details: The iSCSI SAN software is Datacore Sanmelody 2.0.4.2 running on 2 HP Proliant G5 servers. The storage attached to each of the servers is an HP MSA70 and all the iSCSI SAN Volumes that are presented to my 4 ESX hosts are mirrored. I have two iSCSI swithces HP Procurve 1800G-24 that are trunked together. My SANLELODY servers are using NC360T NICs. I team two NICs and have one cable connecting to each iSCSi switch. Each ESX server uses two NICs as well for the iSCSI Network.

    Read the article

  • Why do you use a 3PAR SAN? [closed]

    - by Starfish
    If you use a 3PAR SAN, I’d like to hear what you think about it, particularly compared to the HP EVA. What do you see as its advantages over other SANs like the EVA? What’s so special about the ASIC? We had HP quote us an EVA P6500 and 3PAR V400 with equivalent storage and the 3PAR was nearly twice the cost. My site has two EVA SANs with a combined capacity of ~80 TB. We want to replace the older and larger of the two. We’ve been looking at the EVA and the 3PAR to see which would be a better fit for us. I’m struggling to understand how the 3PAR differs from the EVA from a practical technical standpoint. When I read the sales literature and speak with the HP sales engineers, they spend a lot of time talking about how the 3PAR is better because of its ASIC. It’s ASIC this and ASIC that, but when I press them on how a 3PAR with thin provisioning is better than an EVA with thin provisioning, I can’t get a straight answer. Meanwhile, one of my colleagues, who has more say regarding which SAN we get, is enamored by the 3PAR, and he can’t explain clearly to me why he wants it over the EVA. Our needs are pretty simple. We have 10 servers running VMware and ~100 VMs. We use VMware’s thin provisioning currently, but we would like to start using thin provisioning on the new SAN. We don’t have a need for SSDs or migration between storage tiers. We plan on having FC or SAS drives for our most used data and SATA/FATA drives for the lesser used data which is how we have the EVAs configured. We also do not need any SAN-level snapshotting or replication.

    Read the article

  • Small TCP Window on WAN between 2 Locations

    - by Brent
    Site A: Denver datacenter. 60MBPS. Site B: Chicago. 100MBPS. ICMP pings: Packets: Sent = 176, Received = 176, Lost = 0 (0% loss), Approximate round trip times in milli-seconds: Minimum = 74ms, Maximum = 94ms, Average = 75ms File transfer between sites that never goes past ~7MBPS: Windows Update download at 60MBPS+: Site to site: IPSec VPN using two Cisco 5520's. CPU at 3-4% and lots of memory to spare. The latency between to two sites is very acceptable so I can't see an issue why it is performing so slow when transferring between the two sites. I have found that any type of transfer (FTP, HTTP, Windows file shares) will never go above ~7MBPS. When the WAN was first setup, I was able to get transfers at 50-60MBPS, which is what is expected due to the WAN connection at the Site A at 60MBPS. Then a few days later, I was not able to get anything going faster than ~7MBPS. Is there a upstream router between Denver and Chicago causing this? I want to take the blame away from our setup as downloads from Windows Update go blazing fast and for the first few days after the site to site VPN came up, I was transferring VM images at 50-60MBPS. Our stack: HP P2000 MSA - HP C7000 Chassis - HP Flex-10 - Cisco Gigabit switch - Cisco ASA - WAN

    Read the article

  • Why does clicking on Windows 7 Printer Properties Result In Driver Not Installed?

    - by octopusgrabbus
    The question I need to ask is has anyone heard of getting a "driver not installed" error when clicking on a printer's properties on Windows 7, and is there a workaround? Here are the details of the problem. One of our users has a Windows 7 desktop, and an HP LaserJet 4050 T connected to via a parallel-to-usb converter. The PLC5 universal driver was installed for series 4050 printers. I needed to install the PLC 6 driver, which completed successfully. The user is an administrator of the system, and I was prompted to and accepted running as Administrator to install the driver. After the install, I went to see the 4050's properties and was prompted that the PLC6 driver was not installed. I believe the PLC6 driver was installed, because the PLC5 driver resulted in receiving an official HP error page indicating the printer was "not set up for collating" as the second page of printing two copies of a one page email. This problem did not occur with the PLC 6 driver. Oddly enough, setting back to PLC5 produced the same error about the PLC5 driver not being installed. I ignored/dismissed the error box (did not re-install the driver), and reproduced the error, with the second page being the HP not set up for collating error page. Any thoughts on what is causing this and how to clear it would be appreciated. The closest fix I could find was on a Microsoft tech page, and they had me clear winsock out of a Administrator run command line, followed by a reboot. That did not fix the problem. I have also found this http://social.technet.microsoft.com/Forums/windowsserver/en-US/5101195b-3aca-4699-9a06-db4578614e2d/changing-driver-results-in-printer-driver-is-not-installed-error-on-server-2008?forum=winserverprint and will look into trying some of these suggestions, which appear to me to be a "shotgun" approach to fixing the problem.

    Read the article

  • How to verify power provided to processors is clean

    - by GregC
    Once in a blue moon, I am seeing a blue screen of death on a shiny new Dell R7610 with a single 1100 Watt Dell-provided power supply on a beefy UPS. BCode is 101 (A clock interrupt was not received...), which some say is caused by under-volting a CPU. Naturally, I would have to contact Dell support, and their natural reaction would be to replace a motherboard, a power supply, or CPU, or a mixture of the above components. In synthetic benchmarks, system memory and CPU, as well as graphics memory and CPU perform admirably, staying up for hours and days. My questions are: Is power supply good enough for the application? Does it provide clean enough power to VRMs on the motherboard? Are VRMs good enough for dual Xeon E5-2665? Does C-states logic work correctly? Is there sufficient current provided to PCIe peripherals, such as disk controllers? P.S. Recently, I've gone through the ordeal with HP. They were nice and professional about it, but root cause was not established, and the HP machine still is less than 100%, giving me a blue screen of death once in a couple of months. Here's what quick web-searching turns up: http://www.sevenforums.com/bsod-help-support/35427-win-7-clock-interrupt-bsod-101-error.html#post356791 It appears Dell has addressed the above issue by clocking PCIe bus down to 5GT/sec in A03 BIOS. My disk controllers support PCIe 3.0, meaning that I would have to re-validate stability. Early testing shows improvements. Further testing shows significant decrease in performance on each of the x16 slots with Dell R7610 with A03 BIOS. But now it's running stable. HP machine has received a microcode update in September 2013 SUM (July BIOS) that makes it stable.

    Read the article

  • Flash Backed Write Cache (FBWC) without capacitor pack

    - by Martyn
    I brought a HP Smart Array P410 controller and it is installed and working fine in a HP Prolient Microserver with 4 drives in two RAID 1 arrays. I didn’t realise however that it came without any cache so would only work by directly writing straight to the disk, and the performance was horrible. So I then brought the 512MB Flash Backed Write Cache (FBWC) memory module as I was under the impression that with FBWC I would not need a battery. I got this idea from a forum post. "What do you guys think of the choice between 'BBWC' (battery backed write cache) and 'FBWC' (flash backed write cache)? The flashed based ones use non-volitile memory so need no battery." After installing the cache module however the server pretty much won’t boot. The P410 has a flashing amber light on it, and from the manual that doesn’t sound good. I’ve managed to get to the on board BIOS once and even managed to get to boot to the HP Array Configuration Utility (ACU) CD once, but every other time the Server continuingly reboots once it get to the POST screen and reads ARRAY INITILIZING %%%. The one time I reached the ACU, it reported a problem with the Cache Module. To me, it seems like the cache module is faulty, however the supplier tells me “Do you have an FBWC battery pack, p/n 587324-001, because that is required for the cache to work. If you have it, please complete an RMA form and we'll send a replacement / credit.” Does this sound right to you? I’ve been ordering the parts from the US and I don’t want to spend $77 + $40 p&p on a battery, wait a week for the shipping to find the card is faulty, and I don’t want to send back a working card?

    Read the article

  • What causes a switch port to receive data not destined for it?

    - by user1693454
    We are having an intermittent fault which is effecting one of our control systems on one of our HP Procurve switches. For some reason, this PLC (10mbit port - 192.168.6.56) which is attached directly to the HP Switch intermittantly start's receiving data which is not destined for it. The data is being sent from a Thecus NAS with latest firmware (192.168.6.218) to a physical IBM Server running Win2003R2 and SAP (192.168.6.225). The problem does not just send to this server, it has been to other physical servers in the past too, but always from the Thecus NAS. I am using a monitor port to wireshark what is going in/out of the PLC - normally there would be about 1mb in/out per 2 or 3 minutes - only a server asking the state of the coils. When the problem occurs, there is a flood of data being put onto the PLC line - in this captured instance, about 67mb in less than a minute. Due to this, there is no way that the PLC can be queried as the port is effectively DOSed, in turn killing part of our factory. I know that having Production on the same vlan as IT is not a good idea - I agree, however it cannot be changed at the moment (will have to wait 3 months), as well as the problem has only started happening in the last 3 months. Here is a screen cap of one of the packets being sent from the Thecus NAS which was captured from the PLC port on the HP Switch: And there are over 700 of these in this one 1024kb file. If anyone has any idea on what could be going on, some help would be greatly appreciated. If you need to know anything more, let me know! Cheers!

    Read the article

  • Different subnets routing with just one layer 3 switch

    - by GustavoFSx
    Our current network looks like this: Location 1: 2 Layer 2 switches | subnet 192.168.1.0/24 | Firewall for our VPN Location 2: 1 Layer 2 switch | subnet 192.168.3.0/24 | Firewall for our VPN Location 3: 1 Layer 2 switch | subnet 192.168.5.0/24 | Firewall for our VPN We just got a direct fiber connection between location 1 and 2, we also got a new HP V1910 24G layer 3 switch. I tried to follow the instructions on this site, but I can't get it to work. I think our network should look like this: Location 1: HP Switch FIBER to L2 | subnet 192.168.1.0/24 | Firewall for our VPN Location 2: 1 Layer 2 switch | subnet 192.168.3.0/24 | FIBER to L1 Location 3: 1 Layer 2 switch | subnet 192.168.5.0/24 | Firewall for our VPN So, how can I get routing working on our location 2? It's old gateway was a firewall device on ip 192.168.3.1. I'm thinking on creating a VLAN Interface on 192.168.3.1 on the switch for the Location 2. But how will I handle that on the HP switch that has a direct fiber connection with that switch? Please help, I'm not very good with networking.

    Read the article

  • Cheated!! Please help

    - by Rohit K
    I was experiencing some hard disk problem with my HP laptop. It showed at bootup as system diagnostics are run -- Smart Drive attribute failed. Also i repeatedly got a warning for imminent hard drive failure and thus to back up my data. So i gave my laptop to authorized HP service center for repair. They formatted my hard disk and installed a pirated copy of Win 7 Ultimate (i earlier had genuine Win 7 Home Premium running on my laptop) and they told me they cover out-of-warranty issues and even charged me for it. What's worse is that the hard drive problem is still present and all i am left with is an illegal copy of windows which i think also voids my warranty. What should i do? I mean i did purchase a genuine Windows with my laptop, so there must be some way to reinstall it even when i don't have a genuine copy now on my machine. Can't i get legit keys to reinstall Win 7 from Microsoft because i did pay for the software when i purchased my machine. And if that's not possible, how can i claim warranty and get my hard disk replaced by HP?

    Read the article

  • Ruby Mobile Ports

    - by Nathan Campos
    I'm now learning Ruby because I saw it's a very powerfull language, but now I want to know what mobile ports of Ruby we have and for what devices. PS: I have a HTC S711, HP iPAQ Hx2, Nokia E61, Nokia N95, Palm T|X, Palm Z22, HP Jornada 720..., it's better if I can use it on these platforms, but I'm open to buy other devices, as I'm a mobile addict.

    Read the article

  • java double buffering problem

    - by russell
    Whats wrong with my applet code which does not render double buffering correctly.I am trying and trying.But failed to get a solution.Plz Plz someone tell me whats wrong with my code. import java.applet.* ; import java.awt.* ; import java.awt.event.* ; public class Ball extends Applet implements Runnable { // Initialisierung der Variablen int x_pos = 10; // x - Position des Balles int y_pos = 100; // y - Position des Balles int radius = 20; // Radius des Balles Image buffer=null; //Graphics graphic=null; int w,h; public void init() { Dimension d=getSize(); w=d.width; h=d.height; buffer=createImage(w,h); //graphic=buffer.getGraphics(); setBackground (Color.black); } public void start () { // Schaffen eines neuen Threads, in dem das Spiel l?uft Thread th = new Thread (this); // Starten des Threads th.start (); } public void stop() { } public void destroy() { } public void run () { // Erniedrigen der ThreadPriority um zeichnen zu erleichtern Thread.currentThread().setPriority(Thread.MIN_PRIORITY); // Solange true ist l?uft der Thread weiter while (true) { // Ver?ndern der x- Koordinate repaint(); x_pos++; y_pos++; //x2--; //y2--; // Neuzeichnen des Applets if(x_pos>410) x_pos=20; if(y_pos>410) y_pos=20; try { Thread.sleep (30); } catch (InterruptedException ex) { // do nothing } Thread.currentThread().setPriority(Thread.MAX_PRIORITY); } } public void paint (Graphics g) { Graphics screen=null; screen=g; g=buffer.getGraphics(); g.setColor(Color.red); g.fillOval(x_pos - radius, y_pos - radius, 2 * radius, 2 * radius); g.setColor(Color.green); screen.drawImage(buffer,0,0,this); } public void update(Graphics g) { paint(g); } } what change should i make.When offscreen image is drawn the previous image also remain in screen.How to erase the previous image from the screen??

    Read the article

  • Sun Fire X4270 M3 SAP Enhancement Package 4 for SAP ERP 6.0 (Unicode) Two-Tier Standard Sales and Distribution (SD) Benchmark

    - by Brian
    Oracle's Sun Fire X4270 M3 server achieved 8,320 SAP SD Benchmark users running SAP enhancement package 4 for SAP ERP 6.0 with unicode software using Oracle Database 11g and Oracle Solaris 10. The Sun Fire X4270 M3 server using Oracle Database 11g and Oracle Solaris 10 beat both IBM Flex System x240 and IBM System x3650 M4 server running DB2 9.7 and Windows Server 2008 R2 Enterprise Edition. The Sun Fire X4270 M3 server running Oracle Database 11g and Oracle Solaris 10 beat the HP ProLiant BL460c Gen8 server using SQL Server 2008 and Windows Server 2008 R2 Enterprise Edition by 6%. The Sun Fire X4270 M3 server using Oracle Database 11g and Oracle Solaris 10 beat Cisco UCS C240 M3 server running SQL Server 2008 and Windows Server 2008 R2 Datacenter Edition by 9%. The Sun Fire X4270 M3 server running Oracle Database 11g and Oracle Solaris 10 beat the Fujitsu PRIMERGY RX300 S7 server using SQL Server 2008 and Windows Server 2008 R2 Enterprise Edition by 10%. Performance Landscape SAP-SD 2-Tier Performance Table (in decreasing performance order). SAP ERP 6.0 Enhancement Pack 4 (Unicode) Results (benchmark version from January 2009 to April 2012) System OS Database Users SAPERP/ECCRelease SAPS SAPS/Proc Date Sun Fire X4270 M3 2xIntel Xeon E5-2690 @2.90GHz 128 GB Oracle Solaris 10 Oracle Database 11g 8,320 20096.0 EP4(Unicode) 45,570 22,785 10-Apr-12 IBM Flex System x240 2xIntel Xeon E5-2690 @2.90GHz 128 GB Windows Server 2008 R2 EE DB2 9.7 7,960 20096.0 EP4(Unicode) 43,520 21,760 11-Apr-12 HP ProLiant BL460c Gen8 2xIntel Xeon E5-2690 @2.90GHz 128 GB Windows Server 2008 R2 EE SQL Server 2008 7,865 20096.0 EP4(Unicode) 42,920 21,460 29-Mar-12 IBM System x3650 M4 2xIntel Xeon E5-2690 @2.90GHz 128 GB Windows Server 2008 R2 EE DB2 9.7 7,855 20096.0 EP4(Unicode) 42,880 21,440 06-Mar-12 Cisco UCS C240 M3 2xIntel Xeon E5-2690 @2.90GHz 128 GB Windows Server 2008 R2 DE SQL Server 2008 7,635 20096.0 EP4(Unicode) 41,800 20,900 06-Mar-12 Fujitsu PRIMERGY RX300 S7 2xIntel Xeon E5-2690 @2.90GHz 128 GB Windows Server 2008 R2 EE SQL Server 2008 7,570 20096.0 EP4(Unicode) 41,320 20,660 06-Mar-12 Complete benchmark results may be found at the SAP benchmark website http://www.sap.com/benchmark. Configuration and Results Summary Hardware Configuration: Sun Fire X4270 M3 2 x 2.90 GHz Intel Xeon E5-2690 processors 128 GB memory Sun StorageTek 6540 with 4 * 16 * 300GB 15Krpm 4Gb FC-AL Software Configuration: Oracle Solaris 10 Oracle Database 11g SAP enhancement package 4 for SAP ERP 6.0 (Unicode) Certified Results (published by SAP): Number of benchmark users: 8,320 Average dialog response time: 0.95 seconds Throughput: Fully processed order line: 911,330 Dialog steps/hour: 2,734,000 SAPS: 45,570 SAP Certification: 2012014 Benchmark Description The SAP Standard Application SD (Sales and Distribution) Benchmark is a two-tier ERP business test that is indicative of full business workloads of complete order processing and invoice processing, and demonstrates the ability to run both the application and database software on a single system. The SAP Standard Application SD Benchmark represents the critical tasks performed in real-world ERP business environments. SAP is one of the premier world-wide ERP application providers, and maintains a suite of benchmark tests to demonstrate the performance of competitive systems on the various SAP products. See Also SAP Benchmark Website Sun Fire X4270 M3 Server oracle.com OTN Oracle Solaris oracle.com OTN Oracle Database 11g Release 2 Enterprise Edition oracle.com OTN Disclosure Statement Two-tier SAP Sales and Distribution (SD) standard SAP SD benchmark based on SAP enhancement package 4 for SAP ERP 6.0 (Unicode) application benchmark as of 04/11/12: Sun Fire X4270 M3 (2 processors, 16 cores, 32 threads) 8,320 SAP SD Users, 2 x 2.90 GHz Intel Xeon E5-2690, 128 GB memory, Oracle 11g, Solaris 10, Cert# 2012014. IBM Flex System x240 (2 processors, 16 cores, 32 threads) 7,960 SAP SD Users, 2 x 2.90 GHz Intel Xeon E5-2690, 128 GB memory, DB2 9.7, Windows Server 2008 R2 EE, Cert# 2012016. IBM System x3650 M4 (2 processors, 16 cores, 32 threads) 7,855 SAP SD Users, 2 x 2.90 GHz Intel Xeon E5-2690, 128 GB memory, DB2 9.7, Windows Server 2008 R2 EE, Cert# 2012010. Cisco UCS C240 M3 (2 processors, 16 cores, 32 threads) 7,635 SAP SD Users, 2 x 2.90 GHz Intel Xeon E5-2690, 128 GB memory, SQL Server 2008, Windows Server 2008 R2 DE, Cert# 2012011. Fujitsu PRIMERGY RX300 S7 (2 processors, 16 cores, 32 threads) 7,570 SAP SD Users, 2 x 2.90 GHz Intel Xeon E5-2690, 128 GB memory, SQL Server 2008, Windows Server 2008 R2 EE, Cert# 2012008. HP ProLiant DL380p Gen8 (2 processors, 16 cores, 32 threads) 7,865 SAP SD Users, 2 x 2.90 GHz Intel Xeon E5-2690, 128 GB memory, SQL Server 2008, Windows Server 2008 R2 EE, Cert# 2012012. SAP, R/3, reg TM of SAP AG in Germany and other countries. More info www.sap.com/benchmark

    Read the article

  • sendto: Invalid Argument

    - by Sylvain
    Hi, I have a list<struct sockaddr_in> _peers I'd like to use for sendto() the list is filled this way struct hostent *hp; hp = gethostbyname(hostname); sockaddr_in sin; bzero(&sin, sizeof(sin)); sin.sin_family = AF_INET; sin.sin_port = htons(port); sin.sin_addr.s_addr = *(in_addr_t *)hp->h_addr; _peers.push_front(sin); and here's how I try to send: for (list<struct sockaddr_in>::iterator it = _peers.begin(); it != _peers.end(); ++it) { if (sendto(_s, "PING", 5, 0, (struct sockaddr *)&(*it), sizeof(struct sockaddr_in)) < 0) perror("sendto"); } outputs: sendto: Invalid argument If I create the struct sockaddr_in right before sendto(), everything works fine, so I guess I fail at using the list properly ... I also tested using &_peers.front() directly and still get the same error ... what am I doing wrong? Thanks in advance,

    Read the article

  • How should I go about implementing a points-to analysis in Maude?

    - by reprogrammer
    I'm going to implement a points-to analysis algorithm. I'd like to implement this analysis mainly based on the algorithm by Whaley and Lam. Whaley and Lam use a BDD based implementation of Datalog to represent and compute the points-to analysis relations. The following lists some of the relations that are used in a typical points-to analysis. Note that D(w, z) :- A(w, x),B(x, y), C(y, z) means D(w, z) is true if A(w, x), B(x, y), and C(y, z) are all true. BDD is the data structure used to represent these relations. Relations input vP0 (variable : V, heap : H) input store (base : V, field : F, source : V) input load (base : V, field : F, dest : V) input assign (dest : V, source : V) output vP (variable : V, heap : H) output hP (base : H, field : F, target : H) Rules vP(v, h) :- vP0(v, h) vP(v1, h) :- assign(v1, v2), vP(v2, h) hP(h1, f,h2) :- store(v1, f, v2), vP(v1, h1), vP(v2, h2) vP(v2, h2) :- load(v1, f, v2), vP(v1, h1), hP(h1, f, h2) I need to understand if Maude is a good environment for implementing points-to analysis. I noticed that Maude uses a BDD library called BuDDy. But, it looks like that Maude uses BDDs for a different purpose, i.e. unification. So, I thought I might be able to use Maude instead of a Datalog engine to compute the relations of my points-to analysis. I assume Maude propagates independent information concurrently. And this concurrency could potentially make my points-to analysis faster than sequential processing of rules. But, I don't know the best way to represent my relations in Maude. Should I implement BDD in Maude myself, or Maude's internal unification based on BDD has the same effect?

    Read the article

  • Suggest the way to design several classes

    - by Oleg Tarasenko
    Hi, I'm building simple application on as3. Kind of starship game. What I want to do is to create several different star ships. Each one should have different images (different look), different sets of animation (e.g. when it's flying, burning, damaged), different kind of weapon and also different controllers (e.g. one can be managed by user, another one by computer, and I want to be able to reuse same ships for AI controller as well as for users controls). Each ship is created in the following way: Create entity Add spatial Add renderers Add other components.... ...... n. init the ship So what I am trying to do: 1) Create StarShip superclass, to store HP (as every ship has it), store spatial (same reason) 2) Create inherited class for any other ship... (It will contain renderer - (responsible for display part), weapon, set of animations), etc What do you think about such way of composition? Maybe it's better to place everything in super class, and then just create instances using long, long, long constructors like: StarShip(hp:HP, animations:DICT, weapon:Weapon, ....) Need advice

    Read the article

  • Behavior of <- NULL on lists versus data.frames for removing data

    - by Ananda Mahto
    Many R users eventually figure out lots of ways to remove elements from their data. One way is to use NULL, particularly when you want to do something like drop a column from a data.frame or drop an element from a list. Eventually, a user comes across a situation where they want to drop several columns from a data.frame at once, and they hit upon <- list(NULL) as the solution (since using <- NULL will result in an error). A data.frame is a special type of list, so it wouldn't be too tough to imagine that the approaches for removing items from a list should be the same as removing columns from a data.frame. However, they produce different results, as can be seen in the example below. ## Make some small data--two data.frames and two lists cars1 <- cars2 <- head(mtcars)[1:4] cars3 <- cars4 <- as.list(cars2) ## Demonstration that the `list(NULL)` approach works cars1[c("mpg", "cyl")] <- list(NULL) cars1 # disp hp # Mazda RX4 160 110 # Mazda RX4 Wag 160 110 # Datsun 710 108 93 # Hornet 4 Drive 258 110 # Hornet Sportabout 360 175 # Valiant 225 105 ## Demonstration that simply using `NULL` does not work cars2[c("mpg", "cyl")] <- NULL # Error in `[<-.data.frame`(`*tmp*`, c("mpg", "cyl"), value = NULL) : # replacement has 0 items, need 12 Switch to applying the same concept to a list, and compare the difference in behavior. ## Does not fully drop the items, but sets them to `NULL` cars3[c("mpg", "cyl")] <- list(NULL) # $mpg # NULL # # $cyl # NULL # # $disp # [1] 160 160 108 258 360 225 # # $hp # [1] 110 110 93 110 175 105 ## *Does* drop the `list` items while this would ## have produced an error with a `data.frame` cars4[c("mpg", "cyl")] <- NULL # $disp # [1] 160 160 108 258 360 225 # # $hp # [1] 110 110 93 110 175 105 The main questions I have are, if a data.frame is a list, why does it behave so differently in this scenario? Is there a foolproof way of knowing when an element will be dropped, when it will produce an error, and when it will simply be given a NULL value? Or do we depend on trial-and-error for this?

    Read the article

  • Boot from USB on MediaSmart EX485

    - by Matt Hanson
    I have an HP MediaSmart EX485. I'm attempting to install Vail on it with a USB flash drive and this guide: http://www.mediasmartserver.net/2010/04/26/how-to-install-windows-home-server-vail-on-the-hp-mediasmart-server/. I'm having issues getting the server to boot from the USB flash drive. The MediaSmart itself being headless doesn't help matters. The flash drive has an LED on it for disk activity, and I'm able to see that it's detected when the server is powered on, but it's definitely not booting from it. Any ideas?

    Read the article

< Previous Page | 39 40 41 42 43 44 45 46 47 48 49 50  | Next Page >