Search Results

Search found 11512 results on 461 pages for 'usb mass storage'.

Page 437/461 | < Previous Page | 433 434 435 436 437 438 439 440 441 442 443 444  | Next Page >

  • ESXi 5.1 ghettoVCB stuck at Clone: 10% done

    - by stormdrain
    Trying to run ghettoVCB for the first time here. I am using a NAS that is set up as a datastore on the host. I did a dry run and it completed without error. The VM is ~500GB and there is only one on the host that I'm trying to backup. I proceeded to start the actual backup: ./ghettoVCB.sh -m vmname -g ghettoVCB.conf It goes though the config and looks like it's taking off: 2013-10-24 11:43:19 -- info: CONFIG - USING GLOBAL GHETTOVCB CONFIGURATION FILE = ghettoVCB.conf 2013-10-24 11:43:19 -- info: CONFIG - VERSION = 2013_01_11_0 2013-10-24 11:43:19 -- info: CONFIG - GHETTOVCB_PID = 17398616 2013-10-24 11:43:19 -- info: CONFIG - VM_BACKUP_VOLUME = /vmfs/volumes/nas2tb-001/esxi4 2013-10-24 11:43:19 -- info: CONFIG - VM_BACKUP_ROTATION_COUNT = 3 2013-10-24 11:43:19 -- info: CONFIG - VM_BACKUP_DIR_NAMING_CONVENTION = 2013-10-24_11-43-18 2013-10-24 11:43:19 -- info: CONFIG - DISK_BACKUP_FORMAT = thin 2013-10-24 11:43:19 -- info: CONFIG - POWER_VM_DOWN_BEFORE_BACKUP = 0 2013-10-24 11:43:19 -- info: CONFIG - ENABLE_HARD_POWER_OFF = 0 2013-10-24 11:43:19 -- info: CONFIG - ITER_TO_WAIT_SHUTDOWN = 4 2013-10-24 11:43:19 -- info: CONFIG - POWER_DOWN_TIMEOUT = 5 2013-10-24 11:43:19 -- info: CONFIG - SNAPSHOT_TIMEOUT = 15 2013-10-24 11:43:19 -- info: CONFIG - LOG_LEVEL = info 2013-10-24 11:43:19 -- info: CONFIG - BACKUP_LOG_OUTPUT = /tmp/ghettoVCB-2013-10-24_11-43-18-17398616.log 2013-10-24 11:43:19 -- info: CONFIG - ENABLE_COMPRESSION = 0 2013-10-24 11:43:19 -- info: CONFIG - VM_SNAPSHOT_MEMORY = 0 2013-10-24 11:43:19 -- info: CONFIG - VM_SNAPSHOT_QUIESCE = 0 2013-10-24 11:43:19 -- info: CONFIG - ALLOW_VMS_WITH_SNAPSHOTS_TO_BE_BACKEDUP = 0 2013-10-24 11:43:19 -- info: CONFIG - VMDK_FILES_TO_BACKUP = all 2013-10-24 11:43:19 -- info: CONFIG - VM_SHUTDOWN_ORDER = 2013-10-24 11:43:19 -- info: CONFIG - VM_STARTUP_ORDER = 2013-10-24 11:43:19 -- info: CONFIG - EMAIL_LOG = 0 2013-10-24 11:43:19 -- info: 2013-10-24 11:43:22 -- info: Initiate backup for vmname 2013-10-24 11:43:22 -- info: Creating Snapshot "ghettoVCB-snapshot-2013-10-24" for serv2 Destination disk format: VMFS thin-provisioned Cloning disk '/vmfs/volumes/esxi4-storage/vmname/vmname_1.vmdk'... Clone: 10% done. and it's been that way for over an hour now. Stuck at Clone: 10% done.. Thing is: I can see the vmdk on the NAS. And it looks like almost the whole thing is there. On the NAS it's showing ~430GB but on vSphere Client Summary is shows as 507GB. I don't see the vmdk on the NAS growing any more. The logfile mimics some of the above and is sitting at "Creating Snapshot..." and nothing else is coming in. Is the vmdk on the NAS showing all those GB because of the provisioning or something? i.e. is the size of the file not necessarily indicative of the amount of actual data that has been copied? Is there are reason it might be "Stuck" at 10%? i.e. could it really be taking this long? Any other tips? Thanks. Edit: as soon as I hit the Submit button, I glance over to see that it has incremented to 11% done. Good to know it'll be complete sometime around when the sun explodes.

    Read the article

  • All the Gear and No Idea: Suggestions for re-designing my home/office/entertainment network

    - by 5arx
    Help/ Advice/ Suggestions please: I have a load of kit that I love but which currently operate in disconnected, sometimes counter-productive way. Because I never really had a masterplan I just added these things one after another and connected them up in ad hoc ways. Since I bought my Macbook I've found I spend much less time on the MacPro that was until then my main machine. Perversely, as my job involves writing .Net software, I spend a lot of Mac time actually inside a Windows 7 VM. I stream media from the HP box to the PS3 and thus to the TV, but its not without its limitations/annoyances. We listen to each other's iTunes libraries but the music files are all over the place and it would be good to know they were all safely in one location (and fully backed up). I need to come up with a strategy that will allow me to use all the kit for work, play (recording live music, making tunes, iMovie work), pushing/streaming media to the TV and sharing files with my other half (she uses a Windows laptop and her iPod touch). Ideally I'd like to be able to work on any of the machines and have a shared homedrive that was visible to all machines so all my current files were synced up wherever i was. It would be great if I could access everything securely and quickly over the web. I'd also like to be able to set up a background backup process. The kit list thus far: Apple MacPro 8GB/3x250GB RAID0 + 1TB Apple MacBook Pro 13" 8GB/250GB - I spend a lot of my work time on a Windows 7 VM on this. Crappy Acer laptop (for children's use - iPlayer, watching movies/tv files) HP Proliant Server 4GB/80GB+160GB+300GB Sun Ultra 10 2 x 80GB (old, but in top-notch condition) PS3 160GB iPod Classic 2 x 8GB iPod Touch Observations: Part of the problem is our dual use of Windows and OS X - we can't go for a pure NT style roaming profile. Because the server is also used for hosting test/beta applications and a SQL Server db, it can't be dedicated to file serving. The two Macs really could do with sharing a roaming profile or similar. I'd love to be able to do something useful with the Ultra 10. My other half has been trying to throw it away for over five years now and regularly ask what function it serves in my study :-( I've got no shortage of 500GB external USB hard drives iMovie files are very large and ideally would be processed on a RAID system. Apple's TimeMachine isn't so great. If anyone could suggest all or part of a setup that would fulfil some of my requirements I'd be very grateful. I am willing to consider purchasing one or two more bits of kit (an Apple TV and a Squeezebox have been moted by friends) if they will help make efficiencies rather than add to the chaos and confusion. Thanks for looking.

    Read the article

  • kernel panic after LVM setup

    - by Manuel Sopena Ballesteros
    I broke my webserver... My setup is: VMWare ESXi environemt CPanel installed CentOS release 6.5 (Final) 4 CPUs 2G RAM 2x VM disks 100G each LVM system This was my previous storage settings (the server was working fine at this time): # df -h Filesystem Size Used Avail Use% Mounted on /dev/mapper/vg_test01-lv_root 95G 1.4G 88G 2% / tmpfs 939M 0 939M 0% /dev/shm /dev/sdb1 99G 188M 94G 1% /tmp /dev/sda1 485M 54M 407M 12% /boot My web developer asked me to merge /tmp and / disks so this is what I did: Delete /dev/sdb1 partition using fdisk Create a new partition as LVM on /dev/sdb1 using fdisk Create a new physical volume -- pvcreate /dev/sdb1 Extend volume group -- vgextend /dev/sdb1 vg_test01 Extend logical volume -- lvextend -l +100%FREE /dev/vg_test01/lv_root Resize filesystem -- resize2fs /dev/vg_test01/lv_root This is the new configuration: # df -h Filesystem Size Used Avail Use% Mounted on /dev/mapper/vg_test01-lv_root 213G 105G 97G 52% / tmpfs 939M 0 939M 0% /dev/shm /dev/sda1 485M 54M 407M 12% /boot /usr/tmpDSK 4.0G 145M 3.6G 4% /tmp Since I have the new settings my web server is throwing kernel panics quite often (around every 2 days). The message says: INFO: task <taskName>:<pid> blocked for more than 120 seconds. The list of process affected that I can see from the console are: mysqld queueprocd httpd suphp vmtoolsd loop0 auditd The only way I can fix this is reseting (cold reboot) the VM. I don't think it is a hardware issue as sar is not showing any bottleneck: Linux 2.6.32-431.3.1.el6.x86_64 (test01) 08/22/2014 _x86_64_ (4 CPU) 12:00:01 AM CPU %user %nice %system %iowait %steal %idle 12:10:01 AM all 26.86 0.01 0.98 0.57 0.00 71.57 12:20:01 AM all 1.78 0.02 1.03 0.08 0.00 97.09 12:30:01 AM all 26.34 0.02 0.85 0.05 0.00 72.74 12:40:01 AM all 27.12 0.01 1.11 1.22 0.00 70.54 12:50:01 AM all 1.59 0.02 0.94 0.13 0.00 97.32 01:00:01 AM all 26.10 0.01 0.77 0.04 0.00 73.07 01:10:01 AM all 27.51 0.01 1.16 0.14 0.00 71.18 01:20:01 AM all 1.80 0.07 1.06 0.08 0.00 96.99 01:30:01 AM all 26.19 0.01 0.78 0.05 0.00 72.96 01:40:01 AM all 26.62 0.02 0.87 0.05 0.00 72.45 01:50:02 AM all 1.35 0.01 0.87 0.02 0.00 97.75 02:00:01 AM all 26.11 0.02 0.69 0.02 0.00 73.17 02:10:01 AM all 26.73 0.02 0.89 0.14 0.00 72.21 02:20:01 AM all 1.45 0.01 0.92 0.04 0.00 97.58 02:30:01 AM all 26.59 0.01 1.06 0.03 0.00 72.31 02:40:01 AM all 26.27 0.01 0.72 0.05 0.00 72.95 02:50:01 AM all 0.86 0.01 0.50 0.09 0.00 98.53 03:00:01 AM all 25.61 0.02 0.39 0.03 0.00 73.96 03:10:01 AM all 26.30 0.08 0.66 0.14 0.00 72.82 03:20:01 AM all 0.81 0.01 0.51 0.04 0.00 98.63 03:30:02 AM all 26.15 0.02 0.53 0.07 0.00 73.24 03:40:01 AM all 26.06 0.01 0.47 0.04 0.00 73.42 03:50:01 AM all 0.96 0.02 0.51 0.03 0.00 98.48 Average: all 17.69 0.02 0.79 0.14 0.00 81.36 06:58:14 AM LINUX RESTART 07:00:01 AM CPU %user %nice %system %iowait %steal %idle 07:10:01 AM all 1.04 0.02 0.57 0.95 0.00 97.42 07:20:02 AM all 0.66 0.01 0.39 0.06 0.00 98.87 07:30:01 AM all 25.71 0.01 0.45 0.16 0.00 73.67 07:40:01 AM all 25.88 0.01 0.35 0.08 0.00 73.68 07:50:01 AM all 1.13 0.02 0.55 0.11 0.00 98.19 As you can see the server became unresponsive at 03.50 AM and I had to reset the VM at 06.58 AM to bring the website up again. I would appreciate any help/assistance to fix this issue. thank you very much

    Read the article

  • Cannot run a VM with more than three network interfaces with KVM

    - by Bostonvaulter
    I'm running KVM on top of Ubuntu 10.10 Server I can create VM's (Virtual Machine) and network interfaces fine but I cannot seem to add more than three network interfaces. As soon as I have a VM with four network interfaces it gets stuck on startup at the starting SeaBIOS page with this message: Starting SeaBIOS (version pre-0.6.1-20100702_143500-palmer) So far I've verified this with two VM's, a Ubuntu 10.10 desktop and a Vyatta router. The specific network hardware I assign to the VM's doesn't seem to matter. I'm trying to have one bridged interface and three private networks using Vyatta to route between them. Does anyone know why I can't run a VM with more than three network interfaces? Edit: Additionally the KVM thread responsible for the specific VM hangs using ~100% CPU (i.e. one core). Here's the command for the process that is hanging: /usr/bin/kvm -S -M pc-0.12 -enable-kvm -m 512 -smp 1,sockets=1,cores=1,threads=1 -name vyatta -uuid 6dff7c94-6810-423e-5fea-fec10da0e9b7 -nodefaults -chardev socket,id=monitor,path=/var/lib/libvirt/qemu/vyatta.monitor,server,nowait -mon chardev=monitor,mode=readline -rtc base=utc -boot c -drive file=/home/rams/virtual-machines/vyatta.img,if=none,id=drive-ide0-0-0,boot=on,format=raw -device ide-drive,bus=ide.0,unit=0,drive=drive-ide0-0-0,id=ide0-0-0 -drive if=none,media=cdrom,id=drive-ide0-1-0,readonly=on,format=raw -device ide-drive,bus=ide.1,unit=0,drive=drive-ide0-1-0,id=ide0-1-0 -device rtl8139,vlan=0,id=net0,mac=00:54:00:be:cc:4b,bus=pci.0,addr=0x3 -net tap,fd=97,vlan=0,name=hostnet0 -device rtl8139,vlan=1,id=net1,mac=52:54:00:da:59:ed,bus=pci.0,addr=0x5 -net tap,fd=98,vlan=1,name=hostnet1 -device rtl8139,vlan=2,id=net2,mac=52:54:00:ce:22:b6,bus=pci.0,addr=0x6 -net tap,fd=99,vlan=2,name=hostnet2 -device rtl8139,vlan=3,id=net3,mac=52:54:00:1e:bc:46,bus=pci.0,addr=0x7 -net tap,fd=101,vlan=3,name=hostnet3 -chardev pty,id=serial0 -device isa-serial,chardev=serial0 -usb -vnc 127.0.0.1:0 -k en-us -vga cirrus -device virtio-balloon-pci,id=balloon0,bus=pci.0,addr=0x4 Edit: I've also found an error in dmesg that might be related (it also shows up when running virtd in verbose mode): 14:47:24.399: warning : qemudParsePCIDeviceStrs:1422 : Unexpected exit status '1', qemu probably failed I've also tried disabling app armor but that doesn't seem to make a difference.

    Read the article

  • libvirt qemu/kvm migration problem

    - by Panda
    I am using kvm and libvirt on my Dell server. Now i am trying to migrate one virtual machine from a physical server to another. However, I failed everytime. In virsh on physicalServer1, I typed: virsh # migrate virtualmachine1 qemu+ssh://username@physicalServer2/system error: operation failed: migration to 'tcp:physicalServer2:49163' failed: migration failed Then I searched FAQ part on libvirt.org. It says: error: operation failed: migration to '...' failed: migration failed This is an error often encountered when trying to migrate with QEMU/KVM. This typically happens with plain migration, when the source VM cannot connect to the destination host. You will want to make sure your hosts are properly configured for migration (see the migration section of this FAQ) I managed to ssh physicalServer2 from a shell on virtualmachine1 so the above red part did not explain my failure. I also open ports on physicalServer2, iptables -L shows following information: Chain INPUT (policy ACCEPT) target prot opt source destination ACCEPT udp -- anywhere anywhere udp dpt:domain ACCEPT tcp -- anywhere anywhere tcp dpt:domain ACCEPT udp -- anywhere anywhere udp dpt:bootps ACCEPT tcp -- anywhere anywhere tcp dpt:bootps ACCEPT udp -- anywhere anywhere udp dpt:domain ACCEPT tcp -- anywhere anywhere tcp dpt:domain ACCEPT udp -- anywhere anywhere udp dpt:bootps ACCEPT tcp -- anywhere anywhere tcp dpt:bootps ACCEPT tcp -- anywhere anywhere state NEW tcp dpts:49152:49215 Chain FORWARD (policy ACCEPT) target prot opt source destination ACCEPT all -- anywhere 192.168.122.0/24 state RELATED,ESTABLISHED ACCEPT all -- 192.168.122.0/24 anywhere ACCEPT all -- anywhere anywhere REJECT all -- anywhere anywhere reject-with icmp-port-unreachable REJECT all -- anywhere anywhere reject-with icmp-port-unreachable ACCEPT all -- anywhere 192.168.122.0/24 state RELATED,ESTABLISHED ACCEPT all -- 192.168.122.0/24 anywhere ACCEPT all -- anywhere anywhere REJECT all -- anywhere anywhere reject-with icmp-port-unreachable REJECT all -- anywhere anywhere reject-with icmp-port-unreachable Chain OUTPUT (policy ACCEPT) target prot opt source destination The /var/log/libvirt/qemu/virtualmachine1.log on physicalServer2: 2011-05-06 13:37:30.708: starting up LC_ALL=C PATH=/usr/local/sbin:/usr/local/bin:/usr/bin:/usr/sbin:/sbin:/bin QEMU_AUDIO_DRV=none /usr/bin/kvm -S -M pc-0.14 -enable-kvm -m 2048 -smp 1,sockets=1,cores=1,threads=1 -name openjudge-test -uuid a8c704bc-a4f9-90db-3e57-40e60b00aac1 -nodefconfig -nodefaults -chardev socket,id=charmonitor,path=/var/lib/libvirt/qemu/virtualmachine1.monitor,server,nowait -mon chardev=charmonitor,id=monitor,mode=readline -rtc base=utc -boot c -drive file=/media/nfs/virtualmachine1.img,if=none,id=drive-ide0-0-0,format=raw -device ide-drive,bus=ide.0,unit=0,drive=drive-ide0-0-0,id=ide0-0-0 -drive if=none,media=cdrom,id=drive-ide0-1-0,readonly=on,format=raw -device ide-drive,bus=ide.1,unit=0,drive=drive-ide0-1-0,id=ide0-1-0 -netdev tap,fd=20,id=hostnet0 -device rtl8139,netdev=hostnet0,id=net0,mac=00:16:36:8a:22 :a0,bus=pci.0,addr=0x3 -chardev pty,id=charserial0 -device isa-serial,chardev=charserial0,id=serial0 -usb -vnc 127.0.0.1:2 -vga cirrus -incoming tcp:0.0.0.0:49163 -device virtio-balloon-pci,id=balloon0,bus=pci.0,addr=0x4 char device redirected to /dev/pts/0 2011-05-06 13:37:30.915: shutting down The /var/log/libvirt/qemu/virtualmachine1.log on physicalServer1 is empty. Both physical servers are using Ubuntu 11.04. The libvirt and kvm used are installed by apt-get. The libvirt version is 0.8.8.

    Read the article

  • Windows 7 x64 installation freezes on new PC build

    - by jhsowter
    Symptoms While attempting to install Windows 7 (64 bit) on my new PC build, it freezes usually at the point where it is expanding the windows image, but has frozen as early as accepting the licence agreement, and as late as just after the first restart. My specs are at the bottom of the post. So far I have tried the following to identify the problem, in rough chronological order: Tried different hard drives with different sata cables. Same symptoms. I later used a different computer to install windows on the same hard drive with no problems. Tried the RAM in different slots, and tried one RAM stick instead of two. Same symptoms. Updated the BIOS to 1.60. Same symptoms. Ran Memtest86+ with RAM in dual channel. It passed about 6 times when I left it running overnight. Used USB to install windows instead of an optical drive. Same symptoms. Change SATA configuration from AHCI to IDE. Same symptoms. Tried various different SATA ports. Same symptoms. Updated BIOS to 1.70. Same symptoms. I saw the RAM did not list my motherboard as being supported even though the motherboard did list the RAM as being supported. So I tried some Kingston DDR3 1333MHz RAM instead. Same symptoms. Other (possibly) pertinent information My CPU idles at about 30 °C. I can't tell what it gets to when it's working. When I installed the CPU, the lever which locks the CPU in place took quite a bit of force to pull down. Now I didn't just yank it down without rechecking the CPU was seated properly about 5 times, but it does seems unusual, and I wonder if the CPU was seated badly if I would see these symptoms? I am out of ideas and don't know how to diagnose any further. I suppose either the motherboard or CPU must be the problem. I am on the verge of taking it to a specialist. The Question How should I proceed from here? Is there anything I can rule out as being the source of the symptoms I am seeing? My Specs CPU: Intel i5 3570k RAM: G.Skill RipjawsX 8GB kit HDD: single 3.5" 500GB SATA or 160GB 2.5" SATA (at different times and sometime together. But no RAID or anything). MB: ASRock Extreme4 Z77 PSU: Silverstone Strider Plus 600W ST60F-P

    Read the article

  • How to diagnose repeated "Starting up database '<dbname>'"

    - by Richard Slater
    I have a SQL 2008 server which is predominantly used as a development server, in the last two weeks it has been having occasional "fits", I have isolated the cause of these fits as CHECKDB being run almost continuiously, the following log information is logged to the Windows Event Log (Source: MSSQLSERVER, Category: Server): Event: 1073758961, Message: Starting up database 'DBName1'. Event: 1073758961, Message: Starting up database 'DBName2'. Event: 1073759397, Message: CHECKDB for database 'DBName1' finished without errors on 2010-07-19 20:29:26.993 (local time). This is an informational message only; no user action is required. Event: 1073759397, Message: CHECKDB for database 'DBName1' finished without errors on 2010-07-19 20:29:26.993 (local time). This is an informational message only; no user action is required. This is repeated every 1-2 seconds untill SQL Server is restarted or the offending databases are detatched. I initially thought that it was a problem with the databases so I took a backup and restored them to a SQL Express instance, all of the data is in tact, and CHECKDB runs without problem. The two databases that were causing a problem last week were not being used; so I took full backups of them and detached the databases, this resolved the problem. However at 0100 GMT this morning to other totally unrelated databases started showing the same problems. There is nothing in the event log to suggest that something happened to the server such as a restart, there are no messages about processes crashing or issues being detected with the storage controller. Speaking to the owner of the company this computer has suffered from "gremlins" in the past, however advice was taken and the motherboard was replaced and the computer rebuilt, memory and processor are the same. Stats: O/S: Windows 2008 Standard Build 6002 CPU: 2x Pentium Dual-Core E5200 @ 2.5GHz RAM: 2GB SQL: 2008 Standard 10.0.2531 Edit: someone posted then deleted a comment about AutoClose, it was turned on on the databases affected. It seems that best practice is to disable it so I have done that with the folllowing. EXECUTE sp_MSforeachdb 'IF (''?'' NOT IN (''master'', ''tempdb'', ''msdb'', ''model'')) EXECUTE (''ALTER DATABASE [?] SET AUTO_CLOSE OFF WITH NO_WAIT'')' I won't know if the problem recurs for some time so I am still open to further answers.

    Read the article

  • OCZ Vertex 2 not recognized by Ubuntu installer

    - by Zsub
    As I boot into the Ubuntu 10.10 (or 11.04, doesn't matter) live environment or installer, it just refuses to recognise my Vertex 2. It reports the disk as ATA and not supporting smart, shows no serial number, and doesn't list the size correctly. All fdisk tells me is Unable to read /dev/sda (it's the only storage in the PC). I'm now running a temporary install of Windows 7 off of it, which worked like a charm, so where am I going wrong with Ubuntu... Specs: Asus M4N68T-M LE V2 (BIOS 0702, most recent) OCZ Vertex 2 SSD 60 GB Amd Athlon II X4 640 Patriot PSD34G13332 4GB DDR3 ram (two banks) EDIT I installed a second drive, installed Ubuntu on that and booted, it recognised the SSD just fine. I'm now trying to apt-get upgrade the live-environment. I wonder if there is any way to sort of install Ubuntu from Ubuntu (I boot into the working install on the other drive, install it on the SSD and then boot from the SSD). EDIT2 Ok, so that doesn't work. The install detects the SSD, however, it cannot format it. EDIT3 After a fresh boot I can read out SMART-data and even perform a read-benchmark, but if I try to format it, or do a write-bench, it'll crap out and after that it says SMART is not supported. So basically it seems I can't write to the disk, as it will stop working when I do, I will try to run repeated read-benchmarks to see if that has any effect. EDIT4 I'm running several read benchmarks on the drive right now, they give results that are to be expected from an SSD. If the read-benches don't fail, I can use fdisk on the disk, but it is now stuck trying to re-read the partition table after issueing the 'w' command. EDIT5 Parted Magic did recognize the drive and with hdparm -I even could tell me the drive was in a frozen state. I powercycled it (just pull out the plug from the SSD and plug it back in) and it wasn't frozen anymore. After that I could upgrade the firmware on the drive (still using Parted Magic) and format it to Ext4. After I rebooted into the Ubuntu installer, it wouldn't get recognized and hdparm didn't want to talk to it saying HDIO_DRIVE_CMD(identify) failed: Invalid exchange. EDIT6 For some reason if I enable one of the RAID controllers (the one the SSD is connected to, obviously) Ubuntu will let me format it, mount it and write to it. The installer also recognizes it. However if the raid controller is enabled but no array is defined the motherboard can't boot from it :(

    Read the article

  • Windows 7 x64 "upgrade" repair fails

    - by Polynomial
    I've been running into issues with Windows Update, which I can't seem to fix. The hotfixes don't work, nor does the Windows update readyness tool, or the manual SP1 upgrade. I get various esoteric errors which nobody seems to have a fix for. Looks like some of the update cache is corrupt and digital signatures seem to be broken on some packages / Windows Update components. Long story short, I have discovered the only option is to do a repair operation on the OS, to repair everything. It's so corrupt that only a complete replacement will fix it. According to various sources (including MSKB) one can perform a repair by running an in-place upgrade. I've got the Windows 7 Ultimate retail disc, which I've inserted into my machine. I ran setup.exe and went through in the following order: Install now Go online to get latest updates (I've also tried not getting updates) Wait for updates to be downloaded Select Windows 7 Ultimate (x64 architecture) and click next Accept the T&Cs, click next Click Upgrade At this point it spends a minute on the "checking compatibility" screen, after which I get the following error: The following issues are preventing Windows from upgrading. Cancel the upgrade, complete each task, and then restart the upgrade to continue. You can’t upgrade 64-bit Windows to a 32-bit version of Windows. To upgrade, obtain a 64-bit version of the installation disc, or go online to see how to install Windows 7 and keep your files and settings. 32-bit Windows cannot be upgraded to a 64-bit version of Windows. To upgrade, obtain a 32-bit version of the Windows installation disc. It also mentions a warning about potential conflicts with a storage driver and VS2010, but that doesn't seem to be the blocking issue. My currently installed version of Windows is Ultimate 64-bit (absolutely sure of this) and the disc is definitely a x86 / x64 combined Ultimate retail disc. There seem to be a few people who have run into this (e.g. this question), but I've not seen any answers. I've checked the event viewer, but can't spot anything in there that's related. Any idea how I can get this working? P.S: Just to pre-empt the inevitable "are you suuuuuuuuuuuuure it's x64 Ultimate?" questions:

    Read the article

  • Using Amazon S3 for multiple remote data site uploads, securely

    - by Aitch
    I've been playing about with Amazon S3 a little for the first time and like what I see for various reasons relating to my potential use case. We have multiple (online) remote server boxes harvesting sensor data that is regularly uploaded every hour or so (rsync'ed) to a VPS server. The number of remote server boxes is growing regularly and forecast to keep growing (hundreds). The servers are geographically dispersed. The servers are also automatically built, therefore generic with standard tools and not bespoke per location. The data is many hundreds of files per day. I want to avoid a situation where I need to provision more VPS storage, or additional servers every time we hit the VPS capacity limit, after every N server deployments, whatever N might be. The remote servers can never be considered fully secure due to us not knowing what might happen to them when we are not looking. Our current solution is a bit naive and simply restricts inbound rsync only over ssh to known mac address directories and a known public key. There are plenty of holes to pick in this, I know. Let's say I write or use a script like s3cmd/s3sync to potentially push up the files. Would I need to manage hundreds of access keys and have each server customized to include this (do-able, but key management becomes nightmarish?) Could I restrict inbound connections somehow (eg by mac address), or just allow write-only to any client that was running the script? ( i could deal with a flood of data if someone got into a system? ) having a bucket per remote machine does not seem feasible due to bucket limits? I don't think I want to use a single common key as if one machine is breached then potentially, a malicious hack could get access to the filestore key and start deleting for ll clients, correct? I hope my inexperience has not blinded me to some other solution that might be suggested! I've read lots of examples of people using S3 for backup, but can't really find anything about this sort of data collection, unless my google terminology is wrong... I've written more than I should here, perhaps it can be summarised thus: In a perfect world I just want to have one of our techs install a new remote server into a location and it automagically starts sending files home with little or no intervention, and minimises risk? Pipedream or feasible? TIA, Aitch

    Read the article

  • Logitech Optical Mouse Frozen In Middle of Windows XP Pro Screen

    - by Code Sherpa
    I have a Logitech Optical Mouse/Keyboard. I have been using them just fine with the system drivers for almost a year now. I recently updated my Kaspersky software and rebooted. Now the mouse is frozen in the middle of my screen. I am not able to login to the Windows XP Pro box that has the frozen mouse (because i can't work the mouse) but am able to remote desktop to this computer. Things I know / have tried: When I boot on the problem computer, I am able to use the keyboard, but not the mouse. I have installed the latest version of Logitech's SetPoint (with the updated drivers) on the problem computer (via remote desktop) and that didn't seem to matter. I bought new batteries for the mouse and that didn't matter. I have tried the mouse/keyboard on another computer and the mouse works just fine there. My suspicion is that the Kaspersky install has overwritten a driver of some sort. Things I have not done (and would appreciate detailed steps if you feel this is the way to go): 1) Uninstalled all the mouse drivers on the machine and reboot. Then, reinstall. Note: When I get to the Device Manager I don't see an option for Human Interface Devices (where the mouse device is). Here are my options: Computer, Disk Drives, DVD/CD-Rom drives, Floppy controllers, IDE ATA/ATAPI, Imaging devices, Network Adapters, Other devices, Ports, Processors, Sound, video, and gaming, System devices, USB controllers. Also, I should point out that Video Controller is the only thing under Other devices and it has a yellow exclamation mark. The same is true for all the items under Universal Serial Bus controllers. I think this means I have to update my BIOS but, since my mouse was working just fine without doing that, I don't think that is my problem. So, how do I get to my Mouse Device? 2) Update my BIOS. Note: As pointed out above, I don't think this matters as my mouse was working just fine under my computer's current BIOS version. Thanks for your help.

    Read the article

  • Clonezilla restore from Samba - no 'restoredisk' option

    - by MT_Head
    I used a CloneZilla LiveCD to back up a couple of Windows machines to a Samba share. Now I'm trying to restore those images, and CloneZilla won't even give me the 'restoredisk' or 'restorepart' options on the menu. I'm guessing that this is because CZ isn't recognizing a valid image... but why? Here's a listing of the folder on the Samba share: -rwxrwxrwx 1 marc users 319 May 31 03:45 blkdev.list -rwxrwxrwx 1 marc users 5307 May 31 04:41 clonezilla-img -rwxrwxrwx 1 marc users 4 May 31 04:31 disk -rwxrwxrwx 1 marc users 16091 May 31 04:31 Info-dmi.txt -rwxrwxrwx 1 marc users 11029 May 31 04:31 Info-lshw.txt -rwxrwxrwx 1 marc users 1502 May 31 04:31 Info-lspci.txt -rwxrwxrwx 1 marc users 170 May 31 04:31 Info-packages.txt -rwxrwxrwx 1 marc users 80 May 31 04:41 Info-saved-by-cmd.txt -rwxrwxrwx 1 marc users 10 May 31 04:31 parts -rwxrwxrwx 1 marc users 2097152000 May 31 04:06 sda1.ntfs-ptcl-img.gz.aa -rwxrwxrwx 1 marc users 247361656 May 31 04:08 sda1.ntfs-ptcl-img.gz.ab -rwxrwxrwx 1 marc users 823182034 May 31 04:31 sda2.ntfs-ptcl-img.gz.aa -rwxrwxrwx 1 marc users 36 May 31 03:45 sda-chs.sf -rwxrwxrwx 1 marc users 31744 May 31 03:45 sda-hidden-data-after-mbr -rwxrwxrwx 1 marc users 512 May 31 03:45 sda-mbr -rwxrwxrwx 1 marc users 315 May 31 03:45 sda-pt.parted -rwxrwxrwx 1 marc users 285 May 31 03:45 sda-pt.parted.compact -rwxrwxrwx 1 marc users 259 May 31 03:45 sda-pt.sf (I've been experimenting with various permissions trying to get this to work; that's why they're currently all "rwxrwxrwx"...) I've got my CZ LiveCD stuck in a (different) machine with a 160GB SATA disk that I'm fine with overwriting; although CZ doesn't show a directory listing, it does show that the correct folder is mounted as /home/partimag. But a moment later, after selecting either Beginner or Expert, I'm only presented with the "savedisk", "saveparts", and "exit" options. What am I doing wrong? I am confident that the initial backup was successful; I can post the log if desired, or any other information that might be germane. Edit: I've copied the contents of the folder onto a 16GB USB stick and set THAT as /home/partimag. Still nothing. What the hell is CZ looking for?

    Read the article

  • What "pieces" are needed in order to set up a cluster of physical servers?

    - by Chris Dutrow
    Background: Currently, we use Rackspace cloud servers. We have no intention to stop using them, but would like to look into setting up a cluster of physical servers (probably desktop computers in the $400 range with 8gb memory each) to offset some of our load and work as a secondary, more powerful, less reliable system. To put things in perspective, we can buy comparable desktop computers for the same price as we pay in one month to rent them on Rackspace Cloud. I understand that this is generally a dumb idea. However, in this particular instance, the server cluster is needed for its computation power. It is not mission-critical, it does not host a consumer-facing website, and if it goes down for a day or two, its not really a problem. Currently, we have access to business class verizon fios. If I understand correctly, we can get at least 25 dedicated IP addresses with this service, this should be enough. Requirements: Each server runs Linux Centos 6.3 Some of the servers run Python and execute processes from a task queue (Redis or RabbitMQ) Some of the servers are capable of serving static files and Python driven REST APIs Some of the servers host a Cassandra database cluster One or more of the servers are a Redis database servers One or more of the servers are PostgreSQL servers Questions: What kind of router or switch is needed? We would like the computers to be able to communicate effectively with each other via internal IP addresses. This is especially important for communicating with servers hosting Redis that need to be able to respond to requests very quickly. Are there special switches or routers that need to be used to connect the servers together? Are Desktop computers ok for this? We have found that we are mostly RAM-bottle necked, I understand that some servers have highly superior CPUs, but I'm not sure we need CPU power as much as we need RAM, which is cheap in Desktop computers. Will we have problems with the WIFI cards in the desktops or any other unexpected hardware limitation? What tools should be used to "image" the servers. For example, when we get an installation right for a Redis server or Cassandra node, are there tools that come with Linux Centos 6.3 to image the server to a USB drive or something like that? Or do we need to use some other software for this? What other things are we missing that we should be concerned about? Thanks so much!

    Read the article

  • Can someone explain RAID-0 in plain English?

    - by Edward Tanguay
    I've heard about and read about RAID throughout the years and understand it theoretically as a way to help e.g. server PCs reduce the chance of data loss, but now I am buying a new PC which I want to be as fast as possible and have learned that having two drives can considerably increase the perceived performance of your machine. In the question Recommendations for hard drive performance boost, the author says he is going to RAID-0 two 7200 RPM drives together. What does this mean in practical terms for me with Windows 7 installed, e.g. can I buy two drives, go into the device manager and "raid-0 them together"? I am not a network administrator or a hardware guy, I'm just a developer who is going to have a computer store build me a super fast machine next week. I can read the wikipedia page on RAID but it is just way too many trees and not enough forest to help me build a faster PC: RAID-0: "Striped set without parity" or "Striping". Provides improved performance and additional storage but no redundancy or fault tolerance. Because there is no redundancy, this level is not actually a Redundant Array of Inexpensive Disks, i.e. not true RAID. However, because of the similarities to RAID (especially the need for a controller to distribute data across multiple disks), simple strip sets are normally referred to as RAID 0. Any disk failure destroys the array, which has greater consequences with more disks in the array (at a minimum, catastrophic data loss is twice as severe compared to single drives without RAID). A single disk failure destroys the entire array because when data is written to a RAID 0 drive, the data is broken into fragments. The number of fragments is dictated by the number of disks in the array. The fragments are written to their respective disks simultaneously on the same sector. This allows smaller sections of the entire chunk of data to be read off the drive in parallel, increasing bandwidth. RAID 0 does not implement error checking so any error is unrecoverable. More disks in the array means higher bandwidth, but greater risk of data loss. So in plain English, how can "RAID-0" help me build a faster Windows-7 PC that I am going to order next week?

    Read the article

  • Transferring a Windows 8 license and proper un- and reinstallation

    - by Kiwi
    Long story short I have two computers: a laptop and a desktop computer. Both have Windows 7 on them. I buy the Windows 8 Pro upgrade. To see if it screws up anything, I install it on my laptop as a guinea pig. I intend to use Windows 8 for my main computer, my desktop, but I want to test it on the laptop, so I know I don’t risk losing access to my desktop and the data on it. I never use my laptop, and only used it, because it already has a Windows 7 installation on it. The problem At some point, I must have entered the license key on my laptop, because when I go to the activation screen on my desktop, I get this: Uh-oh. I can’t use the key on my desktop. Now how the hell do I transfer the key from my laptop to my desktop computer? Answers and suggestions so far Let’s just say that I tried everything possible to get some answers on this matter. The best response I got from Microsoft is this: To install Windows 8 on your desktop, do the following: Uninstall Windows 8 on your laptop Afterwards, install Windows 8 on your desktop If it won’t activate, call product activation at (...) I am not a fan of that last point. The error message does allude to such a solution, however: If you’ve reinstalled Windows or made changes to your hardware recently, you may be able to use your current key. The question My main question is this: has anyone been in a similar situation, and if so, what did you do to resolve this? Failing that, what is the proper way to uninstall the Windows 8 installation on my laptop, and reinstall the Windows 8 installation on my desktop? Ad 1 I have already tried using the “reset” feature on my laptop, but that only resulted in a new Windows 8 installation that was already activated. But which is the right way to uninstall the installation in a way that allows me to use the license key on the desktop computer? Ad 2 Which is the proper way to reinstall the Windows 8 installation on my desktop computer? Why do I even have to reinstall it in the first place? I won’t get around to do this, until my USB key with 3.0 support arrives in the mail, but it is going to be a while, until I find a assuaging response to the best way to go about this anyway.

    Read the article

  • Moving Windows XP from ICH10R RAID 5 to single disk using Linux [migrated]

    - by tudor
    A friend's machine running Windows XP refused to boot recently which is running 3 SATA disks on RAID 5 (which was previously upgraded from RAID 1 not by me). I have determined there to be a disk failure. The disks have been replaced many times in the past few years. I wish to backup the RAID5 partition before I try anything to fix it. The RAID chipset used is ICH10R/DO. So, I plugged in an extra IDE drive and an Ubuntu USB key and looked at the RAID. The partitioning is a mess, but I did find at least one degraded but working RAID array with two partitions, one 79GB and the other 86GB. Then I: 1) Partitioned my IDE disk using fdisk to have a partition of 80GB and bootable, and marked as NTFS. 2) dd the contents of the array to the partition 3) disconnected everything else 4) inserted a Windows XP CD and ran fixboot, fixmbr, and bootcfg. They all run ok and claim that they worked. (e.g. bootcfg detects the Windows partition, fixboot returns saying that it was written correctly.) However, I'm still getting an error like "DISK FAILURE, BOOT DISK NOT FOUND". I have tried running the GRUB rescue disk, which also runs ok, but won't boot into Windows. It just stops with a flashing cursor after chainloader +1, boot. One clue may be that the partitions appear to be wack. One disk has a 79GB RAID partition on a 500GB drive with a offset, the second disk has a 320GB RAID partition across the whole drive. Additionally, the BIOS lists the RAID size as being 149GB. I don't see how this works. How are they even assembling the array when the partitions are so different? I have also tried running the Windows XP automated repair tool, but that didn't work either. I'm presuming this is something simple. Perhaps Windows is attempting to boot into RAID and, upon not finding it, simply crashing? Perhaps the 79GB partitions offset means that it's looking into the disk by that much? Please help!! To clarify: I want to make the single IDE disk bootable with a copy of the array so that I can prove/disprove that it's just that Windows has become corrupted, and use windows tools to correct it before attempting the same thing on the RAID array. That way I have a working backup and can show the process I used to fix it.

    Read the article

  • The Koyal Group Info Mag News¦Charged building material could make the renewable grid a reality

    - by Chyler Tilton
    What if your cell phone didn’t come with a battery? Imagine, instead, if the material from which your phone was built was a battery. The promise of strong load-bearing materials that can also work as batteries represents something of a holy grail for engineers. And in a letter published online in Nano Letters last week, a team of researchers from Vanderbilt University describes what it says is a breakthrough in turning that dream into an electrocharged reality. The researchers etched nanopores into silicon layers, which were infused with a polyethylene oxide-ionic liquid composite and coated with an atomically thin layer of carbon. In doing so, they created small but strong supercapacitor battery systems, which stored electricity in a solid electrolyte, instead of using corrosive chemical liquids found in traditional batteries. These supercapacitors could store and release about 98 percent of the energy that was used to charge them, and they held onto their charges even as they were squashed and stretched at pressures up to 44 pounds per square inch. Small pieces of them were even strong enough to hang a laptop from—a big, fat Dell, no less. Although the supercapacitors resemble small charcoal wafers, they could theoretically be molded into just about any shape, including a cell phone’s casing or the chassis of a sedan. They could also be charged—and evacuated of their charge—in less time than is the case for traditional batteries. “We’ve demonstrated, for the first time, the simple proof-of-concept that this can be done,” says Cary Pint, an assistant professor in the university’s mechanical engineering department and one of the authors of the new paper. “Now we can extend this to all kinds of different materials systems to make practical composites with materials specifically tailored to a host of different types of applications. We see this as being just the tip of a very massive iceberg.” Pint says potential applications for such materials would go well beyond “neat tech gadgets,” eventually becoming a “transformational technology” in everything from rocket ships to sedans to home building materials. “These types of systems could range in size from electric powered aircraft all the way down to little tiny flying robots, where adding an extra on-board battery inhibits the potential capability of the system,” Pint says. And they could help the world shift to the intermittencies of renewable energy power grids, where powerful batteries are needed to help keep the lights on when the sun is down or when the wind is not blowing. “Using the materials that make up a home as the native platform for energy storage to complement intermittent resources could also open the door to improve the prospects for solar energy on the U.S. grid,” Pint says. “I personally believe that these types of multifunctional materials are critical to a sustainable electric grid system that integrates solar energy as a key power source.”

    Read the article

  • Toshiba Satellite L630 broken after bios update

    - by Mustafa Kamal
    I have Toshiba Satellite L630, which has been broken. It had no more OS installed in it. All the disk partition were cleared into one single empty unformatted partition. So I begin to install windows XP on this laptop. Apparently, win XP's driver support for this laptop is very limited. So I have to find almost all important driver (display, sound, etherned, wireless etc) on the net and install it manually one by one. So I start googling, and I got some driver download page from several Toshiba's website (the global version, the europe, asia, etc). Pretty hard to find the exact drivers, but I managed to find pretty good drivers. It's all works quite fine, although still have a few glitches. But everything turned into a big mess when I downloaded the "BIOS Update", which is also listed on Toshiba's official driver directory site. When I installed it, it show a big red warning sign telling me not to do anything while flashing the BIOS . I follow that instruction prudently. The process was finished, and that update BIOS software (it is InsydeH2O BIOS) told me that the BIOS has been succesfully updated and the computer need to restart. So I restart the computer. This is where the problem appear. I can no longer boot to my laptop. The booting process seems to be able to enter windows for a moment (it shows the windows XP loading screen), and then suddenly it just got that hateful blue screen and then instantiy restarts the machine. It goes on a loop. Boot bios - enter XP - blue screen - restart. I can't even try to reinstall my win XP again. Evertime the machine tries to boot to win XP CD, it got the same blue screen as I gets when loading from HDD. Many google search results said that I should open the laptop cover and try to clear CMOS with some kind of jumper or something. Or to unplug/re-plug the CMOS battery. Do I really need to do that? Is there anyway I could do without disassembling my laptop? I read some tricks about booting from USB device but I can't get the exat tools that I need to do that thing... Btw, this is my detailed laptop number photographed from the back of my laptop

    Read the article

  • Turn off email notification from abrt (Automatic Bug Reporting Tool)

    - by Banjer
    I'm configuring CentOS 6.2 and have seen a few "[abrt] full crash report" emails. I understand that abrt is useful for creating crash dumps and what not, so I don't want to disable the service, I just would like to stop getting the crash report emails. I probably have to add something to the config file in /etc/abrt/abrt.conf. I can't seem to find anything in my searches. Any idea? Thanks. Edit: Here is my abrt.conf, which is rather simple. [root@myhost~]# cat /etc/abrt/abrt.conf # Enable this if you want abrtd to auto-unpack crashdump tarballs which appear # in this directory (for example, uploaded via ftp, scp etc). # Note: you must ensure that whatever directory you specify here exists # and is writable for abrtd. abrtd will not create it automatically. # #WatchCrashdumpArchiveDir = /var/spool/abrt-upload # Max size for crash storage [MiB] or 0 for unlimited # MaxCrashReportsSize = 1000 # Specify where you want to store coredumps and all files which are needed for # reporting. (default:/var/spool/abrt) # #DumpLocation = /var/spool/abrt And a listing of /etc/abrt: [root@myhost~]# ls -la /etc/abrt total 32 drwxr-xr-x. 3 root root 4096 Apr 13 06:14 . drwxr-xr-x. 97 root root 12288 Apr 13 03:50 .. -rw-r--r--. 1 root root 527 Dec 13 22:50 abrt-action-save-package-data.conf -rw-r--r--. 1 root root 572 Dec 13 22:50 abrt.conf -rw-r--r--. 1 root root 175 Dec 13 22:50 gpg_keys drwxr-xr-x. 2 root root 4096 Apr 13 06:13 plugins [root@myhost~]# ls -la /etc/abrt/plugins/ total 12 drwxr-xr-x. 2 root root 4096 Apr 13 06:13 . drwxr-xr-x. 3 root root 4096 Apr 13 06:14 .. -rw-r--r--. 1 root root 278 Dec 13 22:50 CCpp.conf Actually all of those conf files above are only a few lines and do not mention anything about mail, email, or notifications.

    Read the article

  • File/printer sharing issues on network with multiple OSes

    - by DanZ
    My workplace consists of computers running a variety of different operating systems, and I have been running into problems getting some of them to connect to a shared drive and printer over the network. Here is a brief description of the computers involved and the issues I have encountered: 1: Dell desktop, Windows Vista Business-- This is the computer I want the others to connect to. It has a USB printer and eSATA hard drive enclosure that I have set up for sharing, with different accounts for the various users. 2: Fujitsu laptop, Windows XP Tablet edition-- No problems. Can connect to both the shared printer and hard drive. 3: Lenovo laptop, Windows Vista Business 64 bit-- No problems. Can connect to both the shared printer and drive. 4: Apple MacBook, OS 10.4-- Can connect to the shared drive, but not to the shared printer. I am aware that the printer issue is due to a known incompatibility between Vista and OS 10.4 and earlier with regards to Samba. It is not a big problem, however, as this computer can access a network printer. 5: Sony laptop, Windows Vista Home Premium-- Can connect to the shared printer, but not the shared drive. It can see computer 1 and its shared drive on the network, and appears to successfully log in to user accounts. However, if you try to access the shared drive, it says you do not have permission. I have tried both standard and administrator accounts, and none can access the drive from this computer. 6: MacBook Pro, OS 10.5 (there are two of these)-- Can connect to the shared printer, but not the shared drive. They can't see computer 1 on the network. For that matter, they also can't see each other or the older Mac, but can see and access shared folders on the XP machine (computer 2) and can see other PCs in the building. I was able to add the shared printer manually by typing in its network location, but was unable to manually add the shared drive in the same way. So, what I am looking for is suggestions on how to get computers 5 and 6 to connect to the shared drive. Since they can already connect to the shared printer (which is on the same computer as the shared drive), it seems reasonable that they should be able to access the drive as well.

    Read the article

  • Trust Bluetooth 4.0 and Bluetooth Headset

    - by Seregwethrin
    Firstly, I'm writing this after 5 hours of nonstop struggle to make it work, so I searched into the deepest websites from Google, and tried many things. I have Trust Bluetooth 4.0 USB adapter (link) Samsung HM1500 Bluetooth Headset Windows 7 64-bit Desktop PC Facts Nothing wrong with the headset. (it works, tested on a phone and a laptop. Problem is all about bluetooth dongle and its driver.) Trust BT adapter can send and receive files even without any driver. I can pair successfully without any driver too. In Headset's Properties, Services tab, Handsfree and Headset services are checked. Problem When I pair with my BT headset, I cannot see it as a sound playback device. Also when I double-click the headset device icon in Bluetooth Devices, in laptop: it opens a connection window where I can connect and disconnect to that device - perfect! in desktop: it opens the properties window, even though Handsfree and Headset services are checked (I check them explicitly, in laptop they came as already checked) - Problem! Unsuccessful driver installations The driver on the Trust's website says "Error 1606 Could not access Network Location" on start, so it doesn't get installed. The driver on Broadcom (link) is being closed with Windows's that classic "has stopped working" error on validation step, so it doesn't get installed too. (Those tests made more than once) Successful installation In the Win64 folder of Trust's driver from their website, if I install through "BTW.msi", it doesn't give me Error 1606 and it gets installed. Then the problem: When I try to start bluetooth from start menu (or it gets started at Windows startup), an error popup says: "BtBalloon.dll is missing..." so it doesn't start. I found BBalloon.dll in the driver folder, I renamed it to BtBalloon.dll, moved into Windows/system32 and Windows/SysWOW64 folders, and it seems working. Or maybe it gets closed behind the scenes. The bluetooth icon is there with or without this driver since Windows has it. Bluetooth Peripheral Device First it didn't get installed from Windows Update. After, I showed the driver folder path in Device Manager and pressed "Explore in this location". Surprisingly, it's being found as "Handsfree" driver. Now even I uninstall the drivers, it still can see the Handsfree. But still, no playback device. Any ideas to guide me? I'm out of ideas.

    Read the article

  • Best Processor for MediaSmart Server?

    - by Kent Boogaart
    I'm trying to figure out what the best possible processor is that I can stick in my HP MediaSmart server. I'm clueless when it comes to correlating CPUs to motherboards. I suspect it's the socket type I care about, but I worry that there's more to it. CPU-Z gives me (excerpt): Processors Information ------------------------------------------------------------------------- Processor 1 ID = 0 Number of cores 1 (max 1) Number of threads 1 (max 1) Name AMD Sempron LE-1150 Codename Sparta Specification AMD Sempron(tm) Processor LE-1150 Package Socket AM2 (940) CPUID F.F.1 Extended CPUID F.7F Brand ID 1 Core Stepping DH-G1 Technology 65 nm Core Speed 1000.0 MHz Multiplier x FSB 5.0 x 200.0 MHz HT Link speed 800.0 MHz Stock frequency 2000 MHz Instructions sets MMX (+), 3DNow! (+), SSE, SSE2, SSE3, x86-64 L1 Data cache 64 KBytes, 2-way set associative, 64-byte line size L1 Instruction cache 64 KBytes, 2-way set associative, 64-byte line size L2 cache 256 KBytes, 16-way set associative, 64-byte line size FID/VID Control yes Max FID 10.0x Max VID 1.350 V P-State FID 0x2 - VID 0x12 (5.0x - 1.100 V) P-State FID 0xA - VID 0x0C (9.0x - 1.250 V) P-State FID 0xC - VID 0x0A (10.0x - 1.300 V) K8 Thermal sensor yes K8 Revision ID 6.0 Attached device PCI device at bus 0, device 24, function 0 Attached device PCI device at bus 0, device 24, function 1 Attached device PCI device at bus 0, device 24, function 2 Attached device PCI device at bus 0, device 24, function 3 Chipset ------------------------------------------------------------------------- Northbridge SiS 761GX rev. 02 Southbridge SiS 966 rev. 59 Graphic Interface AGP AGP Revision 3.0 AGP Transfer Rate 8x AGP SBA supported, enabled Memory Type DDR2 Memory Size 2048 MBytes Channels Single Memory Frequency 200.0 MHz (CPU/5) CAS# latency (CL) 5.0 RAS# to CAS# delay (tRCD) 5 RAS# Precharge (tRP) 5 Cycle Time (tRAS) 15 Bank Cycle Time (tRC) 21 Command Rate (CR) 1T DMI ------------------------------------------------------------------------- DMI BIOS vendor Phoenix Technologies, LTD version R03 date 05/08/2008 DMI System Information manufacturer HP product MediaSmart Server version unknown serial CN68330DGH UUID A482007B-B0CC7593-DD11736A-407B7067 DMI Baseboard vendor Wistron model SJD4 revision A.0 serial unknown DMI System Enclosure manufacturer HP chassis type Desktop chassis serial unknown DMI Processor manufacturer AMD model AMD Sempron(tm) Processor LE-1150 clock speed 2000.0 MHz FSB speed 200.0 MHz multiplier 10.0x DMI Memory Controller correction 64-bit ECC Max module size 4096 MBytes DMI Memory Module designation A0 size 2048 MBytes (double bank) DMI Memory Module designation A1 DMI Memory Module designation A2 DMI Memory Module designation A3 DMI Port Connector designation PS/2 Mouse (internal) port type Mouse Port connector PS/2 connector PS/2 DMI Port Connector designation USB0 (external) port type USB DMI Physical Memory Array location Motherboard usage System Memory correction None max capacity 16384 MBytes max# of devices 4 DMI Memory Device designation A0 format DIMM type unknown total width 64 bits data width 64 bits size 2048 MBytes DMI Memory Device designation A1 format DIMM type unknown total width 64 bits data width 64 bits DMI Memory Device designation A2 format DIMM type unknown total width 64 bits data width 64 bits DMI Memory Device designation A3 format DIMM type unknown total width 64 bits data width 64 bits How do I figure out what options I have for an upgrade?

    Read the article

  • Mongodb: why is my mongo server using two PID's?

    - by Lucas
    I started my mongo with the following command: [lucas@ecoinstance]~/node/nodetest2$ sudo mongod --dbpath /home/lucas/node/nodetest2/data 2014-06-07T08:46:30.507+0000 [initandlisten] MongoDB starting : pid=6409 port=27017 dbpat h=/home/lucas/node/nodetest2/data 64-bit host=ecoinstance 2014-06-07T08:46:30.508+0000 [initandlisten] db version v2.6.1 2014-06-07T08:46:30.508+0000 [initandlisten] git version: 4b95b086d2374bdcfcdf2249272fb55 2c9c726e8 2014-06-07T08:46:30.508+0000 [initandlisten] build info: Linux build14.nj1.10gen.cc 2.6.3 2-431.3.1.el6.x86_64 #1 SMP Fri Jan 3 21:39:27 UTC 2014 x86_64 BOOST_LIB_VERSION=1_49 2014-06-07T08:46:30.509+0000 [initandlisten] allocator: tcmalloc 2014-06-07T08:46:30.509+0000 [initandlisten] options: { storage: { dbPath: "/home/lucas/n ode/nodetest2/data" } } 2014-06-07T08:46:30.520+0000 [initandlisten] journal dir=/home/lucas/node/nodetest2/data/ journal 2014-06-07T08:46:30.520+0000 [initandlisten] recover : no journal files present, no recov ery needed 2014-06-07T08:46:30.527+0000 [initandlisten] waiting for connections on port 27017 It appears to be working, as I can execute mongo and access the server. However, here are the process running mongo: [lucas@ecoinstance]~/node/testSite$ ps aux | grep mongo root 6540 0.0 0.2 33424 1664 pts/3 S+ 08:52 0:00 sudo mongod --dbpath /ho me/lucas/node/nodetest2/data root 6541 0.6 8.6 522140 52512 pts/3 Sl+ 08:52 0:00 mongod --dbpath /home/lu cas/node/nodetest2/data lucas 6554 0.0 0.1 7836 876 pts/4 S+ 08:52 0:00 grep mongo As you can see, there are two PID's for mongo. Before I ran sudo mongod --dbpath /home/lucas/node/nodetest2/data, there were none (besides the grep of course). How did my command spawn two PID's, and should I be concerned? Any suggestions or tips would be great. Additional Info In addition, I may have other issues that might suggest a cause. I tried running mongo with --fork --logpath /home/lucas..., but it did not work. More information below: [lucas@ecoinstance]~/node/nodetest2$ sudo mongod --dbpath /home/lucas/node/nodetest2/data --fork --logpath /home/lucas/node/nodetest2/data/ about to fork child process, waiting until server is ready for connections. forked process: 6578 ERROR: child process failed, exited with error number 1 [lucas@ecoinstance]~/node/nodetest2$ ls -l data/ total 163852 drwxr-xr-x 2 mongodb nogroup 4096 Jun 7 08:54 journal -rw------- 1 mongodb nogroup 67108864 Jun 7 08:52 local.0 -rw------- 1 mongodb nogroup 16777216 Jun 7 08:52 local.ns -rwxr-xr-x 1 mongodb nogroup 0 Jun 7 08:54 mongod.lock -rw------- 1 mongodb nogroup 67108864 Jun 7 02:08 nodetest1.0 -rw------- 1 mongodb nogroup 16777216 Jun 7 02:08 nodetest1.ns Also, my db path folder is not the original location. It was originally created under the default /var/lib/mongodb/ and moved to my local data folder. This was done after shutting down the server via /etc/init.d/mongod stop. I have a Debian Wheezy server, if it matters.

    Read the article

  • Messenger Thinks My Ip is Invalid

    - by Umut Benzer
    Hello. I am using Windows Live Messenger 2009 on Windows 7. I am using a 3G modem (ZTE Propietary USB Modem) I connect to the Internet using a software my ISP provided me. In last three days, my Messenger started to disconnect. Here is what I observed and tried to do: 1- I can browse web, can do FTP transfer etc. and obiviously have a valid IP. 2- I can sign in to Messenger (appear offline) but when I change my status to anything other then appear offline, Messenger says my connection to service has been lost. (However, it exists.) 3- When I run, MSN Connection Troubleshooter, it says my IP is invalid. When I click repair, it says repaired and just after that, I run the troubleshooter again, and it says my IP is invalid again. (However, it is valid and I am browsing the net.) 4- If I connect the Internet through eterhet or wireless there is no problem at all. 5- I re-installed Messenger (deleting all settings manually through registry and folders), re-installed all drivers and software related to USB 3G Modem. It doesn't work. And then, I took a full backup then formatted entire computer, installed a fresh windows 7, after 5 minutes, the same problem occured. What do you recommend? What can I do? Addition As seen on screenshot, it says Server IPv4 adress is 0.0.0.0 It seems like a problem, I don't know if it is. If it is, how can I solve it? Here is what I get, when I netstat. PPP adapter TTNET internet: Connection-specific DNS Suffix . : IPv4 Address. . . . . . . . . . . : 217.174.39.122 Subnet Mask . . . . . . . . . . . : 255.255.255.255 Default Gateway . . . . . . . . . : 0.0.0.0 Wireless LAN adapter Wireless Network Connection 2: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Wireless LAN adapter Wireless Network Connection: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : ege.edu.tr Ethernet adapter Local Area Connection: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Tunnel adapter Local Area Connection* 16: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Tunnel adapter Local Area Connection* 13: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Tunnel adapter 6TO4 Adapter: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Tunnel adapter Local Area Connection* 9: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Tunnel adapter Local Area Connection* 11: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Tunnel adapter Local Area Connection* 12: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Tunnel adapter Local Area Connection* 14: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Tunnel adapter Local Area Connection* 17: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Tunnel adapter Local Area Connection* 25: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Tunnel adapter Local Area Connection* 20: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Tunnel adapter Local Area Connection* 18: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Tunnel adapter Local Area Connection* 19: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Tunnel adapter Local Area Connection* 22: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Tunnel adapter Local Area Connection* 21: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Tunnel adapter Local Area Connection* 15: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Tunnel adapter Local Area Connection* 23: Connection-specific DNS Suffix . : IPv6 Address. . . . . . . . . . . : 2001:0:4137:9e74:2448:3909:2a2c:eb7b Link-local IPv6 Address . . . . . : fe80::2448:3909:2a2c:eb7b%30 Default Gateway . . . . . . . . . : Tunnel adapter Local Area Connection* 24: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Tunnel adapter isatap.{CFFCFEDB-6B53-42E0-B091-548B9ADE9C9D}: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Tunnel adapter Local Area Connection* 26: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Tunnel adapter Local Area Connection* 27: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Tunnel adapter Local Area Connection* 29: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Tunnel adapter Local Area Connection* 31: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Tunnel adapter Local Area Connection* 28: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Tunnel adapter Local Area Connection* 32: Connection-specific DNS Suffix . : IPv6 Address. . . . . . . . . . . : 2002:d9ae:277a::d9ae:277a Default Gateway . . . . . . . . . : 2002:c058:6301::c058:6301 Tunnel adapter Local Area Connection* 30: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Tunnel adapter isatap.{157CF713-B3AC-4701-87A9-14C23CA60AAB}: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Tunnel adapter isatap.ege.edu.tr: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . : Tunnel adapter isatap.{0D3CD01B-0993-4B37-89B8-12557ECF484D}: Media State . . . . . . . . . . . : Media disconnected Connection-specific DNS Suffix . :

    Read the article

  • TomCat starts, but does not load properly

    - by user37136
    Hey guys, I've been working on this for a day now and still don't know what's wrong. I am essentially building a second environment for our web and app server. I got apache to load up just fine, but tomcat is proving to be difficult. It appears to start and load just fine, but when it comes to loading our application, its just got stuck for 2-5 minutes and then shut down. Here is the log on the original machine where it works fine: 2010-02-12 11:52:40,506 INFO Web application servlet context is initializing... 2010-02-12 11:52:40,540 DEBUG Servlet context attribute added: select_jobType=[{1,Undefined}, {100,Completion}, {200,Plugging}, {300,R+M}, {400,Workover}, {500,Swab - tubing}, {600,Swab - fluid}] 2010-02-12 11:52:40,540 DEBUG Servlet context attribute added: select_jobTaskType=[{1,Undefined}, {100,Rod part}, {200,Tubing leak}, {300,Pump change}, {400,Stripping job}, {500,Long stroke}, {600,A/L optimization}] 2010-02-12 11:52:40,541 DEBUG Servlet context attribute added: select_wellType=[{1,Undefined}, {100,Rod pump}, {200,ESP}, {300,Injector}, {400,PC pump}, {500,Co-Rod}, {600,Flowing}, {700,Storage}] 2010-02-12 11:52:40,541 DEBUG Servlet context attribute added: select_assetType=[{1,Rig}, {100,Disabled rig}] 2010-02-12 11:52:40,542 DEBUG Servlet context attribute added: select_state=[{AL,Alabama}, {AK,Alaska}, {AZ,Arizona}, {AR,Arkansas}, {CA,California}, {CO,Colorado}, {CT,Connecticut}, {DE,Delaware}, {FL,Florida}, {GA,Georgia}, {HI,Hawaii}, {ID,Idaho}, {IL,Illinois}, {IN,Indiana}, {IA,Iowa}, {KS,Kansas}, {KY,Kentucky}, {LA,Louisiana}, {ME,Maine}, {MD,Maryland}, {MA,Massachusetts}, {MI,Michigan}, {MN,Minnesota}, {MS,Mississippi}, {MO,Missouri}, {MT,Montana}, {NE,Nebraska}, {NV,Nevada}, {NH,New Hampshire}, {NJ,New Jersey}, {NM,New Mexico}, {NY,New York}, {NC,North Carolina}, {ND,North Dakota}, {OH,Ohio}, {OK,Oklahoma}, {OR,Oregon}, {PA,Pennsylvania}, {RI,Rhode Island}, {SC,South Carolina}, {SD,South Dakota}, {TN,Tennessee}, {TX,Texas}, {UT,Utah}, {VT,Vermont}, {VA,Virginia}, {WA,Washington}, {WV,West Virginia}, {WI,Wisconsin}, {WY,Wyoming}, {ACO,Atlantic Coast Offshore}, {FOAK,Federal Offshore Alaska}, {NGOM,Northern Gulf of Mexico}, {PCO,Pacific Coastal Offshore}] 2010-02-12 11:52:40,542 INFO KeyviewContextMonitor.contextInitialized: Loaded drop-down lists:com/key/portal/web/common/lists.properties 2010-02-12 11:52:40,937 DEBUG Servlet context attribute added: org.apache.struts.action.SERVLET_MAPPING=*.do 2010-02-12 11:52:40,937 DEBUG Servlet context attribute added: org.apache.struts.action.ACTION_SERVLET=org.apache.struts.action.ActionServlet@155d578 2010-02-12 11:52:41,939 DEBUG Servlet context attribute added: org.apache.struts.action.MODULE=org.apache.struts.config.impl.ModuleConfigImpl@e08e9d 2010-02-12 11:52:41,962 DEBUG Servlet context attribute added: org.apache.struts.action.FORM_BEANS=org.apache.struts.action.ActionFormBeans@b31c3c 2010-02-12 11:52:41,967 DEBUG Servlet context attribute added: org.apache.struts.action.FORWARDS=org.apache.struts.action.ActionForwards@102c646 2010-02-12 11:52:41,973 DEBUG Servlet context attribute added: org.apache.struts.action.MAPPINGS=org.apache.struts.action.ActionMappings@127276a 2010-02-12 11:52:41,974 DEBUG Servlet context attribute added: org.apache.struts.action.MESSAGE=org.apache.struts.util.PropertyMessageResources@18cae13 2010-02-12 11:52:41,984 DEBUG Servlet context attribute added: org.apache.struts.action.PLUG_INS=[Lorg.apache.struts.action.PlugIn;@f875ae 2010-02-12 11:52:46,816 INFO Sucessfully loaded application properties com/key/core/properties/application On my second environment, it didn't execute the last line. I start tomcat with the exact same command line !/bin/ksh export JAVA_HOME=/app/java export CATALINA_HOME=/app/tomcat export CATALINA_BASE=/app/keyview/appserver CATALINA_OPTS=" -Xms128m -Xmx800m -Dapplication.props=com/key/core/properties/application -Dlog4j.configuration=com/key/core/log/log4j.xml -Djava.awt.headless=true -Dlog4j.debug" export CATALINA_OPTS ${CATALINA_HOME}/bin/startup.sh I bolded the line that I think are in error. Thanks

    Read the article

< Previous Page | 433 434 435 436 437 438 439 440 441 442 443 444  | Next Page >