Search Results

Search found 17913 results on 717 pages for 'old school rules'.

Page 438/717 | < Previous Page | 434 435 436 437 438 439 440 441 442 443 444 445  | Next Page >

  • Have you changed your coding style recently? It wasn't hard wasn't it?

    - by Ernelli
    I've used to write code in C-like languages using the Allman style, regarding the position of braces. void foo(int bar) { if(bar) { //... } else return; //... } Now the last two years I have been working mostly in JavaScript and when we adopted jslint as part of our QA process, I had to adopt to the Crockford way of doing things. So I had to change the coding style into: function foo(bar) { if (bar) { //... } else { return; } //... } Now apart from comparing a C/C++ example with JavaScript, I must say that my JavaScript-Crockford-coding style now has spread into my C/C++/Java coding when I revise old projects and work on code in those languages that for example has no problem with single line statements or ambiguous newline insertion. I used to consider the later format very awkward, I have never had any problems with adapting my coding style to the one chosen by my predecessors, except for when I was a Junior developer mostly being the solve developer on legacy projects and the first thing I did was to change the indenting style. But now after a couple of months I consider the Allman style a little bit too spacious and feel more comfortable with the K&R-like style. Have you changed your coding style during your career?

    Read the article

  • The Eight Most-Important EBS Techstack Stories in 2010

    - by Steven Chan
    I've never really understood the custom of stuffing a summary of one's family's activities for the year in a Christmas/Hanukkah/Kwanzaa card.  It seems a little self-congratulatory and impersonal.  I'd rather my friends kept authentically in touch throughout the year, but perhaps that's just me.Nonetheless, I see the value of a year-end summary in the IT industry.  I spend a lot of time helping our customers understand the latest new developments... and straightening out confusion over changes to the old and familiar.  It can be hard to keep up with the latest news in this space.Here are the eight most-important news items for 2010, with suggested actions for Apps DBAs:Premier Support for EBS 11.5.10 ended on November 30, 2010You need to be on a minimum baseline of 11.5.10 patches to be eligible for Extended Support.  New patches for EBS 11i released during the Extended Support period will be produced only for the minimum baseline configuration.Action: Ensure that your EBS 11i environments meet the minimum baseline requirements. Minimum Baselines are Emerging for EBS 12.0 Extended SupportExtended Support for EBS 12.0 begins on February 1, 2012.  That's only 13 months away.  Minimum baselines haven't been finalized yet, but the 12.0.6 Release Update Pack and the Financials CPC July 2009 are currently slated.  Action: Ensure that your EBS 12.0 environments meet the currently-specified baseline requirements. Sun, Windows, and Linux users should have upgraded to JDK 6 by nowJDK 5's End of Service Life was October 30, 2009 for those three platforms.  If you're running the E-Business Suite on Sun, Windows, or Linux, you should upgrade your EBS servers to JDK 6.  Alternatively, you can purchase Java for Business support (the equivalent of Extended Support for Java). Action: Upgrade your Sun, Windows, or Linux EBS servers to JDK 6. Premier Support for Database 10gR2 ended on July 31, 2010The 10gR2 Database is now in Extended Support.  If you're still on 10gR2, you should start planning your upgrade to a higher certified database version such as 11gR2 11.2.0.2.Action: Upgrade to 10gR2 databases to 11gR2 11.2.0.2. 

    Read the article

  • Design and Print Your Own Christmas Cards in MS Word, Part 1

    - by Eric Z Goodnight
    Looking for a  little DIY fun this holiday season? Open up familiar tool MS Word and create simple, beautiful Christmas and Holiday cards, and impress your family with your crafting skills. This is the first part of a two part article. In this first section, we’ll tackle design in MS Word. In our second, we’ll cover supplies and proper printing methods to get a great look out of your dusty old inkjet. Latest Features How-To Geek ETC The How-To Geek Guide to Learning Photoshop, Part 8: Filters Get the Complete Android Guide eBook for Only 99 Cents [Update: Expired] Improve Digital Photography by Calibrating Your Monitor The How-To Geek Guide to Learning Photoshop, Part 7: Design and Typography How to Choose What to Back Up on Your Linux Home Server How To Harmonize Your Dual-Boot Setup for Windows and Ubuntu Hang in There Scrat! – Ice Age Wallpaper How Do You Know When You’ve Passed Geek and Headed to Nerd? On The Tip – A Lamborghini Theme for Chrome and Iron What if Wile E. Coyote and the Road Runner were Human? [Video] Peaceful Winter Cabin Wallpaper Store Tabs for Later Viewing in Opera with Tab Vault

    Read the article

  • SQL SERVER – Weekly Series – Memory Lane – #003

    - by pinaldave
    Here is the list of curetted articles of SQLAuthority.com across all these years. Instead of just listing all the articles I have selected a few of my most favorite articles and have listed them here with additional notes below it. Let me know which one of the following is your favorite article from memory lane. 2006 This was the first year of my blogging and lots of new things I was learning as I go. I was indeed an infant in blogging a few years ago. However, as time passed by I have learned a lot. This year was year of experiments and new learning. 2007 Working as a full time DBA I often encoutered various errors and I started to learn how to avoid those error and document the same. ERROR Msg 5174 Each file size must be greater than or equal to 512 KB Whenever I see this error I wonder why someone is trying to attempt a database which is extremely small. Anyway, it does not matter what I think I keep on seeing this error often in industries. Anyway the solution of the error is equally interesting – just created larger database. Dilbert Humor This was very first encounter with database humor and I started to love it. It does not matter how many time we read this cartoon it does not get old. Generate Script with Data from Database – Database Publishing Wizard Generating schema script with data is one of the most frequently performed tasks among SQL Server Data Professionals. There are many ways to do the same. In the above article I demonstrated that how we can use the Database Publishing Wizard to accomplish the same. It was new to me at that time but I have not seen much of the adoption of the same still in the industry. Here is one of my videos where I demonstrate how we can generate data with schema. 2008 Delete Backup History – Cleanup Backup History Deleting backup history is important too but should be done carefully. If this is not carried out at regular interval there is good chance that MSDB will be filled up with all the old history. Every organization is different. Some would like to keep the history for 30 days and some for a year but there should be some limit. One should regularly archive the database backup history. South Asia MVP Open Days 2008 This was my very first year Microsoft MVP. I had Indeed big blast at the event and the fun was incredible. After this event I have attended many different MVP events but the fun and learning this particular event presented was amazing and just like me many others are not able to forget the same. Here are other links related to the event: South Asia MVP Open Day 2008 – Goa South Asia MVP Open Day 2008 – Goa – Day 1 South Asia MVP Open Day 2008 – Goa – Day 2 South Asia MVP Open Day 2008 – Goa – Day 3 2009 Enable or Disable Constraint  This is very simple script but I personally keep on forgetting it so I had blogged it. Till today, I keep on referencing this again and again as sometime a very little thing is hard to remember. Policy Based Management – Create, Evaluate and Fix Policies This article will cover the most spectacular feature of SQL 2008 – Policy-based management and how the configuration of SQL Server with policy-based management architecture can make a powerful difference. Policy based management is loaded with several advantages. It can help you implement various policies for reliable configuration of the system. It also provides additional administrative assistance to DBAs and helps them effortlessly manage various tasks of SQL Server across the enterprise. SQLPASS 2009 – My Very First SQPASS Experience Just Brilliant! I never had an experience such a thing in my life. SQL SQL and SQL – all around SQL! I am listing my own reasons here in order of importance to me. Networking with SQL fellows and experts Putting face to the name or avatar Learning and improving my SQL skills Understanding the structure of the largest SQL Server Professional Association Attending my favorite training sessions Since last time I have never missed a single time this event. This event is my favorite event and something keeps me going. Here are additional post related SQLPASS 2009. SQL PASS Summit, Seattle 2009 – Day 1 SQL PASS Summit, Seattle 2009 – Day 2 SQL PASS Summit, Seattle 2009 – Day 3 SQL PASS Summit, Seattle 2009 – Day 4 2010 Get All the Information of Database using sys.databases Even though we believe that we know everything about our database, we do not know a lot of things about our database. This little script enables us to know so many details about databases which we may not be familiar with. Run this on your server today and see how much you know your database. Reducing CXPACKET Wait Stats for High Transactional Database While engaging in a performance tuning consultation for a client, a situation occurred where they were facing a lot of CXPACKET Waits Stats. The client asked me if I could help them reduce this huge number of wait stats. I usually receive this kind of request from other client as well, but the important thing to understand is whether this question has any merits or benefits, or not. I discusses the same in this article – a bit long but insightful for sure. Error related to Database in Use There are so many database management operations in SQL Server which requires exclusive access to the database and it is not always possible to get it. When any database is online in SQL Server it either applications or system thread often accesses them. This means database can’t have exclusive access and the operations which required this access throws an error. There is very easy method to overcome this minor issue – a single line script can give you exclusive access to the database. Difference between DATETIME and DATETIME2 Developers have found the root reason of the problem when dealing with Date Functions – when data time values are converted (implicit or explicit) between different data types, which would lose some precision, so the result cannot match each other as expected. In this blog post I go over very interesting details and difference between DATETIME and DATETIME2 History of SQL Server Database Encryption I recently met Michael Coles and Rodeney Landrum the author of one of the kind book Expert SQL Server 2008 Encryption at SQLPASS in Seattle. During the conversation we ended up how Microsoft is evolving encryption technology. The same discussion lead to talking about history of encryption tools in SQL Server. Michale pointed me to page 18 of his book of encryption. He explicitly gave me permission to re-produce relevant part of history from his book. 2011 Functions FIRST_VALUE and LAST_VALUE with OVER clause and ORDER BY Some time an interesting feature and smart audience make a total difference in places. From last two days, I have been writing on SQL Server 2012 feature FIRST_VALUE and LAST_VALUE. I created a puzzle which was very interesting and got many people attempt to resolve it. It was based on following two articles: Introduction to FIRST_VALUE and LAST_VALUE Introduction to FIRST_VALUE and LAST_VALUE with OVER clause I even provided the hint about how one can solve this problem. The best part was many people solved the problem without using hints! Try your luck!  A Real Story of Book Getting ‘Out of Stock’ to A 25% Discount Story Available This is a great problem and everybody would love to have it. We had it and we loved it. Our book got out of stock in 48 hours of releasing and stocks were empty. We faced many issues and learned many valuable lessons. Some we were able to avoid in the future and some we are still facing it as those problems have no solutions. However, since that day – our books never gone out of stock. This inspiring learning story for us and I am confident that you will love to read it as well. Introduction to LEAD and LAG – Analytic Functions Introduced in SQL Server 2012 SQL Server 2012 introduces new analytical function LEAD() and LAG(). This function accesses data from a subsequent row (for lead) and previous row (for lag) in the same result set without the use of a self-join . It will be very difficult to explain this in words so I will attempt small example to explain you this function. I had a fantastic time writing this blog post and I am very confident when you read it, you will like the same. Reference: Pinal Dave (http://blog.sqlauthority.com) Filed under: Memory Lane, PostADay, SQL, SQL Authority, SQL Query, SQL Server, SQL Tips and Tricks, T SQL, Technology

    Read the article

  • Silverlight Cream for June 17, 2010 -- #885

    - by Dave Campbell
    In this Issue: Zoltan Arvai, Antoni Dol, Jeff Prosise, David Anson, and John Papa. Shoutouts: Rob Davis has a World Cup Football Stadium tour in Silverlight, Azure, and Bing Maps up: The World Cup Map... cruise around this... tons of features. The Silverlight Team Blog reports that NBC sports is streaming the US Open in Silverlight Adam Kinney announced Expression Studio 4 Launch keynote videos are available From SilverlightCream.com: Data Driven Applications with MVVM Part III: Validation, Bringing the UI Closer Zoltan Arvai's 3rd (and final) part of the Data-Driven MVVM apps is up at SilverlightShow. In this final section he is focusing on validation, and discussion of closer integration to the view. Focus on FocusVisualElement in Silverlight buttons Antoni Dol has a cool post up about the FocusVisualElement, and uses a button to demonstrate how it can be used. Dynamic XAP Discovery with Silverlight MEF Jeff Prosise is discussing Silverlight and MEF ... but better than the normal loading XAP files ... he's doing dynamic discovery of XAP files ... and makes it look easy! Updated analysis of two ways to create a full-size Popup in Silverlight David Anson revisits a prior post with an eye toward Silverlight 4. The feature he's discussing is that you can now hook the Resized event without having browser zoom disabled... and he demonstrates it's use in the code from the old post. Silverlight as a Transmedia Platform (Silverlight TV #33) Jesse Liberty joins John Papa this week with Silverlight TV #33, discussing Transmedia and Silverlight as a Transmedia Platform. Stay in the 'Light! Twitter SilverlightNews | Twitter WynApse | WynApse.com | Tagged Posts | SilverlightCream Join me @ SilverlightCream | Phoenix Silverlight User Group Technorati Tags: Silverlight    Silverlight 3    Silverlight 4    Windows Phone MIX10

    Read the article

  • HPET for x86 BSP (how to build it for WCE8)

    - by Werner Willemsens
    Originally posted on: http://geekswithblogs.net/WernerWillemsens/archive/2014/08/02/157895.aspx"I needed a timer". That is how we started a few blogs ago our series about APIC and ACPI. Well, here it is. HPET (High Precision Event Timer) was introduced by Intel in early 2000 to: Replace old style Intel 8253 (1981!) and 8254 timers Support more accurate timers that could be used for multimedia purposes. Hence Microsoft and Intel sometimes refers to HPET as Multimedia timers. An HPET chip consists of a 64-bit up-counter (main counter) counting at a frequency of at least 10 MHz, and a set of (at least three, up to 256) comparators. These comparators are 32- or 64-bit wide. The HPET is discoverable via ACPI. The HPET circuit in recent Intel platforms is integrated into the SouthBridge chip (e.g. 82801) All HPET timers should support one-shot interrupt programming, while optionally they can support periodic interrupts. In most Intel SouthBridges I worked with, there are three HPET timers. TIMER0 supports both one-shot and periodic mode, while TIMER1 and TIMER2 are one-shot only. Each HPET timer can generate interrupts, both in old-style PIC mode and in APIC mode. However in PIC mode, interrupts cannot freely be chosen. Typically IRQ11 is available and cannot be shared with any other interrupt! Which makes the HPET in PIC mode virtually unusable. In APIC mode however more IRQs are available and can be shared with other interrupt generating devices. (Check the datasheet of your SouthBridge) Because of this higher level of freedom, I created the APIC BSP (see previous posts). The HPET driver code that I present you here uses this APIC mode. Hpet.reg [HKEY_LOCAL_MACHINE\Drivers\BuiltIn\Hpet] "Dll"="Hpet.dll" "Prefix"="HPT" "Order"=dword:10 "IsrDll"="giisr.dll" "IsrHandler"="ISRHandler" "Priority256"=dword:50 Because HPET does not reside on the PCI bus, but can be found through ACPI as a memory mapped device, you don't need to specify the "Class", "SubClass", "ProgIF" and other PCI related registry keys that you typically find for PCI devices. If a driver needs to run its internal thread(s) at a certain priority level, by convention in Windows CE you add the "Priority256" registry key. Through this key you can easily play with the driver's thread priority for better response and timer accuracy. See later. Hpet.cpp (Hpet.dll) This cpp file contains the complete HPET driver code. The file is part of a folder that you typically integrate in your BSP (\src\drivers\Hpet). It is written as sample (example) code, you most likely want to change this code to your specific needs. There are two sets of #define's that I use to control how the driver works. _TRIGGER_EVENT or _TRIGGER_SEMAPHORE: _TRIGGER_EVENT will let your driver trigger a Windows CE Event when the timer expires, _TRIGGER_SEMAPHORE will trigger a Windows CE counting Semaphore. The latter guarantees that no events get lost in case your application cannot always process the triggers fast enough. _TIMER0 or _TIMER2: both timers will trigger an event or semaphore periodically. _TIMER0 will use a periodic HPET timer interrupt, while _TIMER2 will reprogram a one-shot HPET timer after each interrupt. The one-shot approach is interesting if the frequency you wish to generate is not an even multiple of the HPET main counter frequency. The sample code uses an algorithm to generate a more correct frequency over a longer period (by reducing rounding errors). _TIMER1 is not used in the sample source code. HPT_Init() will locate the HPET I/O memory space, setup the HPET counter (_TIMER0 or _TIMER2) and install the Interrupt Service Thread (IST). Upon timer expiration, the IST will run and on its turn will generate a Windows CE Event or Semaphore. In case of _TIMER2 a new one-shot comparator value is calculated and set for the timer. The IRQ of the HPET timers are programmed to IRQ22, but you can choose typically from 20-23. The TIMERn_INT_ROUT_CAP bits in the TIMn_CONF register will tell you what IRQs you can choose from. HPT_IOControl() can be used to set a new HPET counter frequency (actually you configure the counter timeout value in microseconds), start and stop the timer, and request the current HPET counter value. The latter is interesting because the Windows CE QueryPerformanceCounter() and QueryPerformanceFrequency() APIs implement the same functionality, albeit based on other counter implementations. HpetDrvIst() contains the IST code. DWORD WINAPI HpetDrvIst(LPVOID lpArg) { psHpetDeviceContext pHwContext = (psHpetDeviceContext)lpArg; DWORD mainCount = READDWORD(pHwContext->g_hpet_va, GenCapIDReg + 4); // Main Counter Tick period (fempto sec 10E-15) DWORD i = 0; while (1) { WaitForSingleObject(pHwContext->g_isrEvent, INFINITE); #if defined(_TRIGGER_SEMAPHORE) LONG p = 0; BOOL b = ReleaseSemaphore(pHwContext->g_triggerEvent, 1, &p); #elif defined(_TRIGGER_EVENT) BOOL b = SetEvent(pHwContext->g_triggerEvent); #else #pragma error("Unknown TRIGGER") #endif #if defined(_TIMER0) DWORD currentCount = READDWORD(pHwContext->g_hpet_va, MainCounterReg); DWORD comparator = READDWORD(pHwContext->g_hpet_va, Tim0_ComparatorReg + 0); SETBIT(pHwContext->g_hpet_va, GenIntStaReg, 0); // clear interrupt on HPET level InterruptDone(pHwContext->g_sysIntr); // clear interrupt on OS level _LOGMSG(ZONE_INTERRUPT, (L"%s: HpetDrvIst 0 %06d %08X %08X", pHwContext->g_id, i++, currentCount, comparator)); #elif defined(_TIMER2) DWORD currentCount = READDWORD(pHwContext->g_hpet_va, MainCounterReg); DWORD previousComparator = READDWORD(pHwContext->g_hpet_va, Tim2_ComparatorReg + 0); pHwContext->g_counter2.QuadPart += pHwContext->g_comparator.QuadPart; // increment virtual counter (higher accuracy) DWORD comparator = (DWORD)(pHwContext->g_counter2.QuadPart >> 8); // "round" to real value WRITEDWORD(pHwContext->g_hpet_va, Tim2_ComparatorReg + 0, comparator); SETBIT(pHwContext->g_hpet_va, GenIntStaReg, 2); // clear interrupt on HPET level InterruptDone(pHwContext->g_sysIntr); // clear interrupt on OS level _LOGMSG(ZONE_INTERRUPT, (L"%s: HpetDrvIst 2 %06d %08X %08X (%08X)", pHwContext->g_id, i++, currentCount, comparator, comparator - previousComparator)); #else #pragma error("Unknown TIMER") #endif } return 1; } The following figure shows how the HPET hardware interrupt via ISR -> IST is translated in a Windows CE Event or Semaphore by the HPET driver. The Event or Semaphore can be used to trigger a Windows CE application. HpetTest.cpp (HpetTest.exe)This cpp file contains sample source how to use the HPET driver from an application. The file is part of a separate (smart device) VS2013 solution. It contains code to measure the generated Event/Semaphore times by means of GetSystemTime() and QueryPerformanceCounter() and QueryPerformanceFrequency() APIs. HPET evaluation If you scan the internet about HPET, you'll find many remarks about buggy HPET implementations and bad performance. Unfortunately that is true. I tested the HPET driver on an Intel ICH7M SBC (release date 2008). When a HPET timer expires on the ICH7M, an interrupt indeed is generated, but right after you clear the interrupt, a few more unwanted interrupts (too soon!) occur as well. I tested and debugged it for a loooong time, but I couldn't get it to work. I concluded ICH7M's HPET is buggy Intel hardware. I tested the HPET driver successfully on a more recent NM10 SBC (release date 2013). With the NM10 chipset however, I am not fully convinced about the timer's frequency accuracy. In the long run - on average - all is fine, but occasionally I experienced upto 20 microseconds delays (which were immediately compensated on the next interrupt). Of course, this was all measured by software, but I still experienced the occasional delay when both the HPET driver IST thread as the application thread ran at CeSetThreadPriority(1). If it is not the hardware, only the kernel can cause this delay. But Windows CE is an RTOS and I have never experienced such long delays with previous versions of Windows CE. I tested and developed this on WCE8, I am not heavily experienced with it yet. Internet forum threads however mention inaccurate HPET timer implementations as well. At this moment I haven't figured out what is going on here. Useful references: http://www.intel.com/content/dam/www/public/us/en/documents/technical-specifications/software-developers-hpet-spec-1-0a.pdf http://en.wikipedia.org/wiki/High_Precision_Event_Timer http://wiki.osdev.org/HPET Windows CE BSP source file package for HPET in MyBsp Note that this source code is "As Is". It is still under development and I cannot (and never will) guarantee the correctness of the code. Use it as a guide for your own HPET integration.

    Read the article

  • Failed to download repository information Check your Internet connection

    - by Luca Brazza
    I need to check if I have updates for Ubuntu. I think it is 11.05 As you can see this is what it says: Failed to download repository information Check your Internet connection. Details: W:Failed to fetch cdrom://Ubuntu 12.04 LTS _Precise Pangolin_ - Release amd64 (20120425)/dists/precise/main/binary-amd64/Packages Please use apt-cdrom to make this CD-ROM recognized by APT. apt-get update cannot be used to add new CD-ROMs , W:Failed to fetch cdrom://Ubuntu 12.04 LTS _Precise Pangolin_ - Release amd64 (20120425)/dists/precise/restricted/binary-amd64/Packages Please use apt-cdrom to make this CD-ROM recognized by APT. apt-get update cannot be used to add new CD-ROMs , W:Failed to fetch cdrom://Ubuntu 12.04 LTS _Precise Pangolin_ - Release amd64 (20120425)/dists/precise/main/binary-i386/Packages Please use apt-cdrom to make this CD-ROM recognized by APT. apt-get update cannot be used to add new CD-ROMs , W:Failed to fetch cdrom://Ubuntu 12.04 LTS _Precise Pangolin_ - Release amd64 (20120425)/dists/precise/restricted/binary-i386/Packages Please use apt-cdrom to make this CD-ROM recognized by APT. apt-get update cannot be used to add new CD-ROMs , W:Failed to fetch http://ppa.launchpad.net/ferramroberto/java/ubuntu/dists/precise/main/source/Sources 404 Not Found , W:Failed to fetch http://ppa.launchpad.net/ferramroberto/java/ubuntu/dists/precise/main/binary-i386/Packages 404 Not Found , E:Some index files failed to download. They have been ignored, or old ones used instead.

    Read the article

  • How do I re-install Unity after uninstalling gnome-shell?

    - by Florian
    I am using Ubuntu 14.04. I have big issues with the Unity desktop. I installed then uninstalled gnome-shell (using "apt-get autoremove --purge gnome-shell"). Since then, my desktop has no background and no icons. Plus, and this is the bothering part, unity is very unstable. On startup, there is a huge use of memory, much more than before. Sometimes, I also cannot minimize a window without having the desktop freezing and having to kill the process in question with tty1. I have tried to use : apt-get autoremove --purge ubuntu-desktop apt-get install ubuntu-desktop But it does not change a thing. I tried to update my video drivers but it is still the same. How can I reinstall the unity desktop thoroughly (obviously, something in its install is broken) ? If it is not possible, is it safe that I create a new partition on my disk where I will put my files and reinstall Ubuntu on the old partition (I do have a USB install of Ubuntu 14.04 but not enough space to save my files on it) ?

    Read the article

  • Glowing Chess Set Combines LEDs, Chess, and DIY Electronics Fun

    - by ETC
    Anyone who says that the centuries old game of Chess cannot be improved upon has obviously never played with a glowing chess board. Today we take a look at a cheap glass chess set modded to glow from within. Instructables user Tetranitrate had a glass chess set he scored on-the-cheap and had always wanted to illuminate it in some way. He ruled out illuminating the board itself (no good way to keep track of the piece colors) and putting a battery in each piece (too big of a pain, over complicates the design). His final solution, the one seen in the photo here, was to build a wood and copper board, run a low voltage across the surface of the chess board, and affix a conductive copper ring to the bottom of each chess piece to power the LED embedded inside. In this manner the pieces would glow on the board and then go dark as soon as they were removed from play. Hit up the link below for additional details on the build and instructions on building your own. LED Chess Set [Instructables] Latest Features How-To Geek ETC How to Get Amazing Color from Photos in Photoshop, GIMP, and Paint.NET Learn To Adjust Contrast Like a Pro in Photoshop, GIMP, and Paint.NET Have You Ever Wondered How Your Operating System Got Its Name? Should You Delete Windows 7 Service Pack Backup Files to Save Space? What Can Super Mario Teach Us About Graphics Technology? Windows 7 Service Pack 1 is Released: But Should You Install It? Save Files Directly from Your Browser to the Cloud in Chrome and Iron The Steve Jobs Chronicles – Charlie and the Apple Factory [Video] Google Chrome Updates; Faster, Cleaner Menus, Encrypted Password Syncing, and More Glowing Chess Set Combines LEDs, Chess, and DIY Electronics Fun Peaceful Alpine River on a Sunny Day [Wallpaper] Fast Society Creates Mini and Mobile Temporary Social Networks

    Read the article

  • Don&rsquo;t use MySQL .net connector, here is why ?

    - by Anirudha
    Originally posted on: http://geekswithblogs.net/anirugu/archive/2013/11/04/donrsquot-use-mysql-.net-connector-here-is-why.aspxIf you use .net mysql connector and all project new or old use different different version of Mysql .net connector then you need to upgrade it to latest (if you don’t use copy local=true for bin assembly). This is not the single problem happen to me.   In my case I use .net connector 6.7.4.0 and let’s see what happen to me after I start using it. 6.7.4.0 install register the mysql module in machine.config and it’s broke every software you haven’t deployed with Mysql.   Suppose for example I just create a website ( in webmatrix 3) put my index.cshtml and now see what it preview for me. This means I need to add the mysql.Web even I don’t use any kind of database. I need to do every asp.net mvc project no matter they use mysql. it’s problematic when we use older .net  mysql connector in some of my project.   If you have trouble like this simply use nuget and say Bye bye to this trouble.

    Read the article

  • UEFI/GPT Win 7 Load Failure in Dual Boot and no GRUB2 [Ubuntu 12.04]

    - by cristian_jordache
    Configuration: MBB: ASRock X79 Extreme6 Win 7 installed on a INTEL 40GB SSD (GPT partitioned) Ubuntu 14.04 on a CORSAIR 30GB SSD (Ext4 and SWAP) I had Windows 7 installed previously in UEFI mode, using 3 partitions (GPT) and works fine if left alone. In UEFI BIOS settings I can see sometimes a "Windows Boot Manager" and other times (?) a "UEFI Intel" entry for INTEL HDD and Windows will boot properly selecting the one available at that time. I installed Ubuntu 14.04 after Win 7 w/o changing any UEFI BIOS settings and it works fine only if the BIOS is set w/ the Ubuntu partition as the first drive to boot, in AHCI mode. If both SSD drives are connected, the Win7 Intel boot drive can be chosen as first boot device but only as an "AHCI Intel drive" (No "Windows Boot Manager" nor "UEFI Intel device" options available in BIOS Boot menu) and Win7 will not load properly as long as the Ubuntu Crucial SSD is NOT PHYSICALLY DISCONNECTED. Windows will try, start booting for few seconds but will fail replacing Win7 logo and that startup animation with w/ the "old" white progress bar and then and will notify that there is a issue and prompt the user to try to Load Win 7 in Normal Mode again or try a Recovery Mode to fix it. If I let Windows INTEL HDD boot via BIOS/UEFI - Windows Boot manager selection, I may see the purple screen of Grub2 loaded for a while, but there's no selection for Ubuntu or Windows and/or then machine is not booting, showing a black screen and a small command prompt cursor blinking on top. So far the only option I see to have Ubuntu boot side by side w/ Win 7 is to reformat the Win7 SDD and set it boot in legacy BIOS mode with a MBR instead of GPT. Per my understanding this is a quite complex issue to fix (Rod Smith's answer was pretty helpful: UEFI boot on my Asus k52f) but any other suggestions are welcome. I find a bit odd that I can boot properly Windows7 SSD or an Ubuntu DVD using a DVD drive set in UEFI-BIOS in "AHCI mode" and w/ using "UEFI/Windows Boot Manager" booting option but I cannot boot a secondary SSD-HDD w/ Ubuntu having the same BIOS/UEFI Boot configuration. Looks like plugging the second SSD [the Ubuntu partition] is interfering with boot options in UEFI-BIOS.

    Read the article

  • Create a Shortcut To Group Policy Editor in Windows 7

    - by Mysticgeek
    If you’re a system administrator and find yourself making changes in Group Policy Editor, you might want to make a shortcut to it. Here we look at creating a shortcut, pinning it to the Taskbar, and adding it to Control Panel. Note: Local Group Policy Editor is not available in Home versions of Windows 7. Typing gpedit.msc into the search box in the Start menu to access Group Policy Editor can get old fast. To create a shortcut, right-click on the desktop and select New \ Shortcut. Next type or copy the following path into the location field and click Next. c:\windows\system32\gpedit.msc Then give your shortcut a name…something like Group Policy, or whatever you want it to be and click Finish. Now you have your Group Policy shortcut… If you want it on the Taskbar just drag it there to pin it. And that’s all there is to it!   If you want to change the icon, you can use one of the following guides… Customize Icons in Windows 7 Change a File Type Icon in Windows 7 Add Group Policy to Control Panel If you’re using non Home versions of XP, Vista, or Windows 7, check out The Geek’s article on how to Add Group Policy Editor to Control Panel. Similar Articles Productive Geek Tips Add Group Policy Editor to Control PanelQuick Tip: Disable Search History Display in Windows 7Remove Shutdown and Restart Buttons In Windows 7How To Disable Control Panel in Windows 7Allow Users To Run Only Specified Programs in Windows 7 TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips Acronis Online Backup DVDFab 6 Revo Uninstaller Pro Registry Mechanic 9 for Windows Fun with 47 charts and graphs Tomorrow is Mother’s Day Check the Average Speed of YouTube Videos You’ve Watched OutlookStatView Scans and Displays General Usage Statistics How to Add Exceptions to the Windows Firewall Office 2010 reviewed in depth by Ed Bott

    Read the article

  • Geek it Up

    - by BuckWoody
    I’ve run into a couple of kinds of folks in IT. Some really like technology a lot – a whole lot –and others treat it more as a job. For those of you in the second camp, you can go back to your drab, meaningless jobs – this post is for the first group. I’m a geek. Not a little bit of a geek, a really big one. I love technology, I get excited about science and electronics in general, and I read math books when I don’t have to. Yes, I have a Star Trek item or two around the house. My daughter is fluent in both Monty Python AND Serenity. I totally admit it. So if you’re like me (OK, maybe a little less geeky than that), then go for it. Put those toys in your cubicle, wear your fan shirt, but most of all, geek up your tools. No, this isn’t an April Fool’s post – I really mean it. I’ve noticed that when I get the larger monitor, better mouse, cooler keyboard, I LIKE coming to work. It’s a way to reward yourself – I’ve even found that it makes work easier if I have the kind of things I enjoy around to work with. So buy that old “clicky” IBM keyboard, get three monitors, and buy a nice headset so that you can set all of your sounds to Monty Python WAV’s. And get to work. Share this post: email it! | bookmark it! | digg it! | reddit! | kick it! | live it!

    Read the article

  • How to Make Your Verizon FIOS Router 1000% More Secure

    - by The Geek
    If you’ve just switched to Verizon FIOS and they’ve installed the new router in your house, there’s just one problem: it’s set to use lousy WEP encryption by default, instead of the much more secure WPA2. Here’s how to fix it. The problem with WEP encryption is that it can be cracked really easily—a skilled hacker can do it in a few minutes, and even an unskilled geek can do it in just a little more time with the right tools. Once they’ve done that, they can leech off your internet connection and do anything they want—including illegal stuff coming from your network. Note: if you are using an old Nintendo DS connected to the internet, they usually only support WEP encryption, so you may not want to do this Latest Features How-To Geek ETC The Complete List of iPad Tips, Tricks, and Tutorials The 50 Best Registry Hacks that Make Windows Better The How-To Geek Holiday Gift Guide (Geeky Stuff We Like) LCD? LED? Plasma? The How-To Geek Guide to HDTV Technology The How-To Geek Guide to Learning Photoshop, Part 8: Filters Improve Digital Photography by Calibrating Your Monitor The Spam Police Parts 1 and 2 – Goodbye Spammers [Videos] Snow Angels Theme for Windows 7 Exploring the Jungle Ruins Wallpaper Protect Your Privacy When Browsing with Chrome and Iron Browser Free Shipping Day is Friday, December 17, 2010 – National Free Shipping Day Find an Applicable Quote for Any Programming Situation

    Read the article

  • BizTalk 2009 - The Community ODBC Adapter: Installation

    - by Stuart Brierley
    I have previsouly detailed the installation of MySQL, the configuration of MySQL and the installation of the ODBC Data Connector for MySQL.  The reason I needed to install and configure these servers was to provide a test environment for a BizTalk Server 2009 solution I am working on where BizTalk will be querying and populating a MySQL database. To do this I then needed to install and add the Community ODBC adapter from Two Connect: "The Community BizTalk Adapter for ODBC is based on the code that was first made available on GotDotNet a few years ago. TwoConnect has refreshed this code, added an installer, and tested it against the latest BizTalk editions. We are releasing the updates back to the BizTalk developer, user and partner community as part of our ongoing community intitiatives. This is the second adapter package that TwoConnect makes available to the community after the very succesful release of the BizTalk WSE 3 adapter a couple of years ago. This adapter is useful in all ODBC based integration scenarios. The following are the new features added and fixes made to the old code base on GotDotNet." Detailed below are the installation instructions for this adapter.  Downloading and running the installer will load up the splash screen. Next you need to select the installation location for the adapter. You then need to confirm the installation following which you will be shown the installation progress. Assuming all has gone well you should see the installation complete screen. Once the installation has completed successfully you will then need to add the adapter to your BizTalk Server.  To do this open the BizTalk Administration console, expand the Platform Settings and right click on Adapters then select New\Adapter. You should then be able to select the ODBC adapter and choose the display name for the adapter. This adapter will then be shown in the BizTalk Administration console. Next I will be looking at using the ODBC Adapter when: Generating schemas Creating a receive port Creating a send port

    Read the article

  • Bulgogi to Beignets

    - by Randy Walker
    While it’s still a full month away, I’m getting super excited about my upcoming trips. May and June are chock full of events, two of which I’ll have full announcements for within the week.  In mid May I’ll be driving to Dallas to take my 2nd trip to Korea (the bulgogi part).  Seeing a bunch of old friends from my first trip as well as taking a week for some deeper personal things. While in my absence, June 1st-4th, I’ve setup a tour across Arkansas and Texas for two Microsoft employees who work on the Visual Studio & Visual Basic team to talk at various user groups and companies.  Look for my announcement within the next couple of days. As soon as I get back from Korea, I’m off to New Orleans!  It’s been years since I’ve been there (pre-Katrina), and I have a hankering for some Beignets and Cafe Ole from Cafe Du Monde.  The big news?  I’m hosting a PARTY on Bourbon Street!  The party will be very exclusive, featuring a crawfish and shrimp boil, various Cajun dishes, and an open bar.  Huge thanks to Infragistics for putting up the initial sponsor money.  See you guys at Microsoft’s TechEd 2010!

    Read the article

  • Developers are strange

    - by DavidWimbush
    Why do developers always use the GUI tools in SQL Server? I've always found this irritating and just vaguely assumed it's because they aren't familiar with SQL syntax. But when you think about it it, it's a genuine puzzle. Developers type code all day - really heavy code too like generics, lamda functions and extension methods. They (thankfully) scorn the Visual Studio stuff where you drag a table onto the class and it pastes in lots of code to query the table into a DataSet or something. But when they want to add a column to a table, without fail they dive into the graphical table designer. And half the time the script it generates does horrible things like copy the table to another one with the new column, delete the old table, and rename the new table. Which is fine if your users don't care about uptime. Is ALTER TABLE ADD <column definition> really that hard? I just don't get it.

    Read the article

  • Data and Secularism

    - by kaleidoscope
    Ever since we’ve been using Data we’ve been religious. Religious about the way we represent it and equally religious about the way we access it. Be it plain old SQL, DAO, ADO, ADO.Net and I am just referring to religions in MSFT world. A peek outside and I’d need a separate book to list out the Data faiths. Various application areas in networked computing are converging under the HTTP umbrella with a plausible transition to purist HTTP and in turn REST fuelled by the Web2.0 storm. It was time the Data access faiths also gave up the religious silos wrapped around our long worshipped data publishing and access methods. OData is the secular solution we have at hand today. It is an open protocol for sharing data. It can be exposed via REST. It is Open as in the Microsoft Open Specification Promise. This allows virtually everyone to build Data Services for any runtime. OData is one of the key standards for Data publishing/subscribing on Microsoft Codename Dallas. For us .Netters OData data sources can be exposed/consumed via WCF Data Services and the process is very simple, elegant and intuitive. Applications exposing OData Services Sharepoint 2010 IBM Web Sphere Microsoft SQL Azure Windows Azure Table Storage SQL Server Reporting Services   Live OData Services Netflix Open Science Data Initiative Open Government Data Initiatives Northwind database exposed as OData Service and many others Some may prefer to call it commoditization of data, unification of data access strategies or any other sweet name. I for one will stick to my secular definition. :) Technorati Tags: Sarang,OData,MOSP

    Read the article

  • Line Numbering in Notepad-Week 41

    - by OWScott
    You can find this week’s video here. Notepad is so simple, yet so useful. Yet, at times the "Go To" appears to break and doesn't work as expected. This week's video is short and sweet. Learn about line numbering in notepad. One of my all-time favorite applications is notepad. You may think I’m joking, but I’ve grown quite fond of notepad over the years. Like a faithful friend, always there for you when you need it. Whether it’s an old computer or new, it opens instantly. I can’t remember notepad ever crashing. Wish I could say that for most other applications. This week’s lesson is a quick one, but if you’ve ever run into issues with line numbering in notepad, I hope you find it useful. I remember the first time the “Go To” feature didn’t work in notepad for me. It took me a while to figure it out so I hope to save you the grief that I went through. Watch this week’s video for a couple quick tips on the tried and true notepad. This is now week 41 of a 52 week series for the web pro. You can view past and future weeks here: http://dotnetslackers.com/projects/LearnIIS7/ You can find this week’s video here.

    Read the article

  • Weird Net Connection problem

    - by Sarthak
    hullo folks....this is my first thread here Ok,i first installed ubuntu 11.10 the day it released on my old laptop...internet worked fine without configuring anything so now,i installed ubuntu 11.10 on my newer laptop.But it says ,"device not ready(firmware missing". Windows 7 worked absolutely fine on it i also tried using a Netgear routed i use on my HDTV,but ubuntu doesnt detect it Any Help? Thanks in advance Peace Log of lspci command sarthak@sarthak:~$ lspci 00:00.0 Host bridge: Intel Corporation Mobile 4 Series Chipset Memory Controller Hub (rev 07) 00:02.0 VGA compatible controller: Intel Corporation Mobile 4 Series Chipset Integrated Graphics Controller (rev 07) 00:02.1 Display controller: Intel Corporation Mobile 4 Series Chipset Integrated Graphics Controller (rev 07) 00:1a.0 USB Controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #4 (rev 03) 00:1a.1 USB Controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #5 (rev 03) 00:1a.2 USB Controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #6 (rev 03) 00:1a.7 USB Controller: Intel Corporation 82801I (ICH9 Family) USB2 EHCI Controller #2 (rev 03) 00:1b.0 Audio device: Intel Corporation 82801I (ICH9 Family) HD Audio Controller (rev 03) 00:1c.0 PCI bridge: Intel Corporation 82801I (ICH9 Family) PCI Express Port 1 (rev 03) 00:1c.1 PCI bridge: Intel Corporation 82801I (ICH9 Family) PCI Express Port 2 (rev 03) 00:1c.2 PCI bridge: Intel Corporation 82801I (ICH9 Family) PCI Express Port 3 (rev 03) 00:1c.3 PCI bridge: Intel Corporation 82801I (ICH9 Family) PCI Express Port 4 (rev 03) 00:1c.5 PCI bridge: Intel Corporation 82801I (ICH9 Family) PCI Express Port 6 (rev 03) 00:1d.0 USB Controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #1 (rev 03) 00:1d.1 USB Controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #2 (rev 03) 00:1d.2 USB Controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #3 (rev 03) 00:1d.7 USB Controller: Intel Corporation 82801I (ICH9 Family) USB2 EHCI Controller #1 (rev 03) 00:1e.0 PCI bridge: Intel Corporation 82801 Mobile PCI Bridge (rev 93) 00:1f.0 ISA bridge: Intel Corporation ICH9M LPC Interface Controller (rev 03) 00:1f.2 SATA controller: Intel Corporation ICH9M/M-E SATA AHCI Controller (rev 03) 00:1f.3 SMBus: Intel Corporation 82801I (ICH9 Family) SMBus Controller (rev 03) 00:1f.6 Signal processing controller: Intel Corporation 82801I (ICH9 Family) Thermal Subsystem (rev 03) 04:00.0 Network controller: Broadcom Corporation BCM4312 802.11b/g LP-PHY (rev 01) 07:00.0 Ethernet controller: Broadcom Corporation NetLink BCM5906M Fast Ethernet PCI Express (rev 02)

    Read the article

  • Silverlight Cream for May 01, 2010 -- #853

    - by Dave Campbell
    In this Issue: Damian Schenkelman, Rob Eisenberg, Sergey Barskiy, Victor Gaudioso, CorrinaB, Mike Snow, and Adam Kinney. From SilverlightCream.com: Prism’s future: Trying to summarize things Damian Schenkelman collected links to the latest Prism information to provide a reference post, including discussing WP7. MVVM Study - Interlude Rob Eisenberg discusses MVVM - it's beginnings and links out to all the major players old and new. Windows Phone 7 Database Here we go... Sergey Barskiy converted his Silverlight database project to WP7, and it's available on CodePlex... cool! New Silverlight Video Tutorial: How to Save an Image in Your Silverlight Applications Victor Gaudioso has a new video tutorial up... demonstrating saving an image from Silverlight to your hard disk. He also has the source files for download. Enforce Design Guidelines With Styles And Behaviors CorrinaB has a post up discussing attaching behaviors in styles. She has a couple good examples and a sample project to download. Silverlight Tip of the Day #9 – Obtaining Your clients IP Address Mike Snow has Tip number 9 up and he's explaining how to find the client IP address even though it's not natively available from Silverlight or jscript. Expression Blend 4 for Windows Phone in 90 seconds Adam Kinney talks about the release of a new version of the Expression Blend add-in for WP7. He's got links and instructions for removing and upgrading. Stay in the 'Light! Twitter SilverlightNews | Twitter WynApse | WynApse.com | Tagged Posts | SilverlightCream Join me @ SilverlightCream | Phoenix Silverlight User Group Technorati Tags: Silverlight    Silverlight 3    Silverlight 4    Windows Phone MIX10

    Read the article

  • Third-party open-source projects in .NET and Ruby and NIH syndrome

    - by Anton Gogolev
    The title might seem to be inflammatory, but it's here to catch your eye after all. I'm a professional .NET developer, but I try to follow other platforms as well. With Ruby being all hyped up (mostly due to Rails, I guess) I cannot help but compare the situation in open-source projects in Ruby and .NET. What I personally find interesting is that .NET developers are for the most part severely suffering from the NIH syndrome and are very hesitant to use someone else's code in pretty much any shape or form. Comparing it with Ruby, I see a striking difference. Folks out there have gems literally for every little piece of functionality imaginable. New projects are popping out left and right and generally are heartily welcomed. On the .NET side we have CodePlex which I personally find to be a place where abandoned projects grow old and eventually get abandoned. Now, there certainly are several well-known and maintained projects, but the number of those pales in comparison with that of Ruby. Granted, NIH on the .NET devs part comes mostly from the fact that there are very few quality .NET projects out there, let alone projects that solve their specific needs, but even if there is such a project, it's often frowned upon and is reinvented in-house. So my question is multi-fold: Do you find my observations anywhere near being correct? If so, what are your thoughts on quality and quantitiy of OSS projects in .NET? Again, if you do agree with my thoughts on "NIH in .NET", what do you think is causing it? And finally, is it Ruby's feature set & community standpoint (dynamic language, strong focus on testing) that allows for such easy integration of third-party code?

    Read the article

  • Nautilus can't start due to segmentation fault

    - by Dmitriy Sukharev
    Out of the blue I can't start nautilus today. When I try to open any directory it tries to open it, and sometimes I even can see the content of directory, but finally it's closed, after that there are no icons on desktop. When I tried to launch nautilus from terminal, I got: $ nautilus . Initializing nautilus-dropbox 0.7.1 Initializing nautilus-gdu extension Segmentation fault (core dumped) I've tried to move ~/.local/share/gvfs-metadata folder, I don't have nautilus-open-terminal package and don't have file /usr/local/lib/libgtk-3.so.0 Also I can't update system right now. All the time I'm getting the the same hash-sum error: $ sudo apt-get update [sudo] password for dmitriy: Ign http://mirror.mirohost.net precise InRelease Ign http://mirror.mirohost.net precise-updates InRelease Ign http://mirror.mirohost.net precise-security InRelease Hit http://mirror.mirohost.net precise Release.gpg ... Ign http://ppa.launchpad.net precise/main Translation-en Hit http://mirror.mirohost.net precise-security/restricted Translation-en Hit http://mirror.mirohost.net precise-security/universe Translation-en Fetched 1 B in 1s (0 B/s) W: Failed to fetch gzip:/var/lib/apt/lists/partial/mirror.mirohost.net_ubuntu_dists_precise_universe_source_Sources Hash Sum mismatch E: Some index files failed to download. They have been ignored, or old ones used instead. Any ideas how to rescue my system? UPD: In syslog I have the following errors: Jul 7 21:35:02 dmitriy-desktop kernel: [ 58.059141] nautilus[1991]: segfault at 7fc09d9bb700 ip 00007fc0abb5feb6 sp 00007fff6caa4cf8 error 4 in libc-2.15.so[7fc0aba24000+1b3000] Jul 7 21:35:39 dmitriy-desktop kernel: [ 94.356490] update-notifier[3358]: segfault at 7f6507611700 ip 00007f64cc221eb6 sp 00007fffbcc0dd88 error 4 in libc-2.15.so[7f64cc0e6000+1b3000] Jul 7 21:37:45 dmitriy-desktop kernel: [ 220.501859] nautilus[3629]: segfault at 7f9b9744c700 ip 00007f9b7c9c6eb6 sp 00007fff72e990f8 error 4 in libc-2.15.so[7f9b7c88b000+1b3000] UPD2: Ubuntu version is 12.04.

    Read the article

  • What is the best aproach for coding in a slow compilation environment

    - by Andrew
    I used to coding in C# in a TDD style - write/or change a small chunk of code, re-compile in 10 seconds the whole solution, re-run the tests and again. Easy... That development methodology worked very well for me for a few years, until a last year when I had to go back to C++ coding and it really feels that my productivity has dramatically decreased since. The C++ as a language is not a problem - I had quite a lot fo C++ dev experience... but in the past. My productivity is still OK for a small projects, but it gets worse when with the increase of the project size and once compilation time hits 10+ minutes it gets really bad. And if I find the error I have to start compilation again, etc. That is just purely frustrating. Thus I concluded that in a small chunks (as before) is not acceptable - any recommendations how can I get myself into the old gone habit of coding for an hour or so, when reviewing the code manually (without relying on a fast C# compiler), and only recompiling/re-running unit tests once in a couple of hours. With a C# and TDD it was very easy to write a code in a evolutionary way - after a dozen of iterations whatever crap I started with was ending up in a good code, but it just does not work for me anymore (in a slow compilation environment). Would really appreciate your inputs and recos. p.s. not sure how to tag the question - anyone is welcome to re-tag the question appropriately. Cheers.

    Read the article

  • Linqpad with Table Storage

    - by kaleidoscope
    LinqPad as we all know has been a wonderful tool for running ad-hoc queries. With Azure Table storage in picture LinqPad was no longer in picture and we shifted focus to Cloud Storage Studio only to realize the limited and strange querying capabilities of CSS. With some tweaking to Linqpad we can get the comfortable old shoe of ad-hoc queries with LinqPad in the Azure Table storage. Steps: 1. Start LinqPad 2. Right Click in the query window and select “Query Properties” 3. In The Additional References add reference to Microsoft.WindowsAzure.StorageClient, System.Data.Services.Client.dll and the assembly containing the implementation of the DataServiceContext class tied to the Azure table storage. 4. In the additional namespace imports import the same three namespaces mentioned above. 5. Then we need to provide following details. a. Table storage account name and shared key. b. DataServiceContext implementing class in your code. c. A LINQ query. e.x. var storageAccountName = "myStorageAccount";  // Enter valid storage account name var storageSharedKey = "mysharedKey"; // Enter valid storage account shared key var uri = new System.Uri("http://table.core.windows.net/"); var storageAccountInfo = new CloudStorageAccount(new StorageCredentialsAccountKey(storageAccountName, storageSharedKey), false); var serviceContext = new TweetPollDataServiceContext(storageAccountInfo); // Specify the DataServiceContext implementation // The query var query = from row in serviceContext.Table select row;         query.Dump(); Sarang, K

    Read the article

< Previous Page | 434 435 436 437 438 439 440 441 442 443 444 445  | Next Page >