Search Results

Search found 6363 results on 255 pages for 'buford speed'.

Page 44/255 | < Previous Page | 40 41 42 43 44 45 46 47 48 49 50 51  | Next Page >

  • Way to speed up load-balanced ssl using nginx?

    - by paulnsorensen
    So the setup for our website is 4 nodes running rails 3 and nginx 1 that all use the same GoDaddy certificate. Because we are a paid site, we have to maintain PCI-DSS compliance and thus have to use the more expensive SSL ciphers -- also we force SSL using Rack. I've recently switched over to Linode's NodeBalancer (which I've read is an HACluster), and we're not getting the performance we'd ideally like. From what I've read, it looks like terminating the SSL on the nodes using the high cipher is what is causing the poor performance, but I'd like to be thorough. Is there anything I can do? I've read about other ways to terminate the SSL before the NodeBalancer (like using stud), but I don't know enough about these solutions. We certainly don't want to do anything experimental or anything that has a single point of failure. If there really isn't anything I can do to speed up the SSL handshake, my alternative would be to support certain pages on Rails using a secure and insecure subdomain. I've found a few guides that walk through that, but my resulting question is in this situation, would it be better to have nginx handle forcing ssl on the secure subdomain instead of rails? Thanks!

    Read the article

  • Is there any way to limit the turbo boost speed / intensity on i7 lap?

    - by Anonymous
    I've just got a used i7 laptop, one of these overheating pavilions from HP with quad cores. And I really want to find a compromise between the temp and performance. If I use linpack, or some other heavy benchmark, the temp easily gets to 95+, and having a TJ of 100 Degrees, for a 2630QM model, it really gets me throttling, that no cooling pad or even an industrial fan could solve. I figured later that it is due to turbo boost, and if I set my power settings to use 99% of the CPU instead of 100%, and it seems to disable the turbo boost, so the temp gets better. But then again it loses quite a bit of performance. The regular clock is 2GHz, and in turbo boost it gets to 2.6Ghz, but I just wonder if I could limit it to around 2.3Ghz, that would be a real nice thing. Also there is another question I've hard time getting answer to. It seems to me that clocks are very quickly boosting up to max even when not needed, eg, it's ok if the CPU has 0% load, the clocks get to their 800MHz, but even if it gets to about 5% it quickly jumps to a max and even popping up turbo, which seems very strange to me. So I wonder if there is any way to adjust the sensitivity of the Speed Step feature. I believe it would be more logical to demand increased clock if it hits let's say 50% load. I do understand that most of these features are probably hardwired somewhere in the CPU itself or the MB, which has no tuning options just like on many laptops. But I would appreciate if you could recommend some thing, or some software. Thanks

    Read the article

  • How to speed up the reading of innerHTML in IE8?

    - by Dennis Cheung
    I am using JQuery with the DataTable plugin, and now I have a big performnce issue on the following line. aLocalData[jInner] = nTds[j].innerHTML; // jquery.dataTables.js:2220 I have a ajax call, and result string in HTML format. I convert them into HTML nodes, and that part is ok. var $result = $('<div/>').html(result).find("*:first"); // simlar to $result=$(result) but much more faster in Fx Then I activate enable the result from a plain table to a sortable datatable. The speed is acceptable in Fx (around 4sec for 900 rows), but unacceptable in IE8 (more then 100 seconds). I check it deep using the buildin profiler, and found the above single line take all 99.9% of the time, how can I speed it up? anything I missed? nTrs = oSettings.nTable.getElementsByTagName('tbody')[0].childNodes; for ( i=0, iLen=nTrs.length ; i<iLen ; i++ ) { if ( nTrs[i].nodeName == "TR" ) { iThisIndex = oSettings.aoData.length; oSettings.aoData.push( { "nTr": nTrs[i], "_iId": oSettings.iNextId++, "_aData": [], "_anHidden": [], "_sRowStripe": '' } ); oSettings.aiDisplayMaster.push( iThisIndex ); aLocalData = oSettings.aoData[iThisIndex]._aData; nTds = nTrs[i].childNodes; jInner = 0; for ( j=0, jLen=nTds.length ; j<jLen ; j++ ) { if ( nTds[j].nodeName == "TD" ) { aLocalData[jInner] = nTds[j].innerHTML; // jquery.dataTables.js:2220 jInner++; } } } }

    Read the article

  • How can I speed up Subversion checkins? (Using ANKH, latest, Visual Studio 2010)

    - by Timothy Khouri
    I've started working on a new web project with some friends... we are using the latest Subversion server (installed last week), the latest version of ANKH. My web project is a whapping 1.5 megabytes (that's with all images, css files, dll's after compiling, pdb files... etc). Checking in even super small changes (literally adding the letter "x" to a few files for testing)... takes FOREVER! (about 10 seconds - I almost killed myself). The ANKH client is measuring in BYTES PER SECOND ... BYTES? per second... I must be doing something wrong. Does anyone what config file has a joke totallyMessWithPeople=true so that I can turn that off or something? Oh, also, changing one "big" file of a super 10k gains speed up to nearly the speed of light (which is apparently 857 bytes per second). Help me obi wan kenobi, your my only hope! EDIT: As a note... my real work project that uses Visual Source Safe 2005 (I know, ouch) uploads files at about 200-500kbps from this very same computer/internet connection.

    Read the article

  • Why does Tex/Latex not speed up in subsequent runs?

    - by Debilski
    I really wonder, why even recent systems of Tex/Latex do not use any caching to speed up later runs. Every time that I fix a single comma*, calling Latex costs me about the same amount of time, because it needs to load and convert every single picture file. (* I know that even changing a tiny comma could affect the whole structure but of course, a well-written cache format could see the impact of that. Also, there might be situations where 100% correctness is not needed as long as it’s fast.) Is there something in the language of Tex which makes this complicated or impossible to accomplish or is it just that in the original implementation of Tex, there was no need for this (because it would have been slow anyway on those large computers)? But then on the other hand, why doesn’t this annoy other people so much that they’ve started a fork which has some sort of caching (or transparent conversion of Tex files to a format which is faster to parse)? Is there anything I can do to speed up subsequent runs of Latex? Except from putting all the stuff into chapterXX.tex files and then commenting them out?

    Read the article

  • How do I optimize this postfix expression tree for speed?

    - by Peter Stewart
    Thanks to the help I received in this post: I have a nice, concise recursive function to traverse a tree in postfix order: deque <char*> d; void Node::postfix() { if (left != __nullptr) { left->postfix(); } if (right != __nullptr) { right->postfix(); } d.push_front(cargo); return; }; This is an expression tree. The branch nodes are operators randomly selected from an array, and the leaf nodes are values or the variable 'x', also randomly selected from an array. char *values[10]={"1.0","2.0","3.0","4.0","5.0","6.0","7.0","8.0","9.0","x"}; char *ops[4]={"+","-","*","/"}; As this will be called billions of times during a run of the genetic algorithm of which it is a part, I'd like to optimize it for speed. I have a number of questions on this topic which I will ask in separate postings. The first is: how can I get access to each 'cargo' as it is found. That is: instead of pushing 'cargo' onto a deque, and then processing the deque to get the value, I'd like to start processing it right away. I don't yet know about parallel processing in c++, but this would ideally be done concurrently on two different processors. In python, I'd make the function a generator and access succeeding 'cargo's using .next(). But I'm using c++ to speed up the python implementation. I'm thinking that this kind of tree has been around for a long time, and somebody has probably optimized it already. Any Ideas? Thanks

    Read the article

  • How can I speed up a 1800-line PHP include? It's slowing my pageload down to 10sec/view

    - by somerandomguy
    I designed my code to put all important functions in a single PHP file that's now 1800 lines long. I call it in other PHP files--AJAX processors, for example--with a simple "require_once("codeBank.php")". I'm discovering that it takes about 10 seconds to load up all those functions, even though I have nothing more than a few global arrays and a bunch of other functions involved. The main AJAX processor code, for example, is taking 8 seconds just to do a simple syntax verification (whose operational function is stored in codeBank.php). When I comment out the require_once, my AJAX response time speeds up from 10sec to 40ms, so it's pretty clear that PHP's trying to do something with those 1800 lines of functions. That's even with APC installed, which is surprising. What should I do to get my code speed back to the sub-100ms level? Am I failing to get the cache's benefit somehow? Do I need to cut that single function bank file into different pieces? Are there other subtle things that I could be doing to screw up my response time? Or barring all that, what are some tools to dig further into which PHP operations are hitting speed bumps?

    Read the article

  • Fan not working on thinkpad L430, laptop overheating

    - by Dirk B.
    I'm having problems controlling the fan of my Lenovo Thinkpad L430. The fan doesn't start. Without any fan control installed the fan just doesn't run. If I run stress, it does run a little, but it's nowhere near the speed it should be. After a while, the laptop just overheats and stops. I Tried to install tp-fancontrol, and enabled thinkpad_acpi fancontrol=1, but to no avail. If I try to set the fan speed manually, it doesn't start up. In windows, there's a program called TPFanControl. It turns out that this laptop uses a different scheme to control the fan than other thinkpads. The level runs from 0 to 255, and max = 0 and min=255. Now I'm looking for a fan control program that works for linux. Does anyone know if it actually exists? Anyone with any experience on fan control on a L430? Update: sudo pwmconfig gives the following output: # pwmconfig revision 5857 (2010-08-22) This program will search your sensors for pulse width modulation (pwm) controls, and test each one to see if it controls a fan on your motherboard. Note that many motherboards do not have pwm circuitry installed, even if your sensor chip supports pwm. We will attempt to briefly stop each fan using the pwm controls. The program will attempt to restore each fan to full speed after testing. However, it is ** very important ** that you physically verify that the fans have been to full speed after the program has completed. Found the following devices: hwmon0 is acpitz hwmon1/device is coretemp hwmon2/device is thinkpad Found the following PWM controls: hwmon2/device/pwm1 hwmon2/device/pwm1 is currently setup for automatic speed control. In general, automatic mode is preferred over manual mode, as it is more efficient and it reacts faster. Are you sure that you want to setup this output for manual control? (n) y Giving the fans some time to reach full speed... Found the following fan sensors: hwmon2/device/fan1_input current speed: 0 ... skipping! There are no working fan sensors, all readings are 0. Make sure you have a 3-wire fan connected. You may also need to increase the fan divisors. See doc/fan-divisors for more information. regards, Dirk

    Read the article

  • Lenovo Thinkpad L430 overheating due to fan problems

    - by Dirk B.
    This is the same question as Fan not working on thinkpad L430, laptop overheating, but that question has been marked as a duplicate, which it is not, and I cannot reopen it. I'm having problems controlling the fan of my Lenovo Thinkpad L430. The fan doesn't start. Without any fan control installed the fan just doesn't run. If I run stress, it does run a little, but it's nowhere near the speed it should be. After a while, the laptop just overheats and stops. I Tried to install tp-fancontrol, and enabled thinkpad_acpi fancontrol=1, but to no avail. If I try to set the fan speed manually, it doesn't start up. In windows, there's a program called TPFanControl. It turns out that this laptop uses a different scheme to control the fan than other thinkpads. The level runs from 0 to 255, and max = 0 and min=255. Now I'm looking for a fan control program that works for linux. Does anyone know if it actually exists? Anyone with any experience on fan control on a L430? Update: sudo pwmconfig gives the following output: # pwmconfig revision 5857 (2010-08-22) This program will search your sensors for pulse width modulation (pwm) controls, and test each one to see if it controls a fan on your motherboard. Note that many motherboards do not have pwm circuitry installed, even if your sensor chip supports pwm. We will attempt to briefly stop each fan using the pwm controls. The program will attempt to restore each fan to full speed after testing. However, it is ** very important ** that you physically verify that the fans have been to full speed after the program has completed. Found the following devices: hwmon0 is acpitz hwmon1/device is coretemp hwmon2/device is thinkpad Found the following PWM controls: hwmon2/device/pwm1 hwmon2/device/pwm1 is currently setup for automatic speed control. In general, automatic mode is preferred over manual mode, as it is more efficient and it reacts faster. Are you sure that you want to setup this output for manual control? (n) y Giving the fans some time to reach full speed... Found the following fan sensors: hwmon2/device/fan1_input current speed: 0 ... skipping! There are no working fan sensors, all readings are 0. Make sure you have a 3-wire fan connected. You may also need to increase the fan divisors. See doc/fan-divisors for more information. update: If you need it, lspci is available here

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • Do glue records in non-circular dns-lookups speed up domain resolution or not?

    - by Joe Hopfgartner
    Doing a lookup for my domain on http://www.intodns.com/ I noticed theese two messages: In Parent section: DNS Parent sent Glue The parent nameserver g.gtld-servers.net is not sending out GLUE for every nameservers listed, meaning he is sending out your nameservers host names without sending the A records of those nameservers. It's ok but you have to know that this will require an extra A lookup that can delay a little the connections to your site. This happens a lot if you have nameservers on different TLD (domain.com for example with nameserver ns.domain.org.) and in NS section: Glue for NS records INFO: GLUE was not sent when I asked your nameservers for your NS records.This is ok but you should know that in this case an extra A record lookup is required in order to get the IPs of your NS records. The nameservers without glue are: 109.230.225.96 84.201.40.52 You can fix this for example by adding A records to your nameservers for the zones listed above. I do perfectly understand that the primary objective of glue records is to resolve circular dependencies. The classic use case: my domain is example.com and I want to have the nameserver ns1.example.com. This will never work because i cannot know the ip of ns1.example.com if I don't fetch example.com and in order to do that I need to fetch it from ns1.example.com. To resolve this deadlock I add a glue record to ns1.example.com containing the ip adress of the nameserver, so this can work out. So this problem does not occour if the nameservers are in a different TLD than the domain i want to look up. But however to fetch the zone information from the nameservers I need to know their ip adress right? And in order to know that i need to fetch the zone the nameservers are in from their respective nameservers, right? (or rather my ISP needs to do that in the background) So an extra lookup that takes time? If I now have glue records, I know the IP adress right away without the need to look it up - so this should speed up the resolution of my domain, shouldnt it? However my DNS zone provider (tecserver.at) replied that this would make no sense because "we are not running ns1.ourdomain.com an ns1.ourdomain.com as authorative NS for ourdomain.com. This would be the only sense for glue records. Tecserver has a glue record because the NS for tecserver.at are ns1.tecserver.at and ns2.tecserver.at. Therefore a glue record is needed for resolution.

    Read the article

  • Weird Network Behavior of Home Router

    - by Stilgar
    First of all I would like to apologize because what you are going to read will be long and confusing but I am fighting this issue for 3 days now and am out of ideas. At home I have the following setup 50Mbps Internet connects into a home router A 2 desktop computers connect to router A via standard FTP LAN cables including one where the cable is ~20m long. a second router B connects to router A via standard FTP LAN cable X (~20m long). several devices connect to the wireless network of router B and there are a couple of desktop computers connected to it through FTP LAN cables. For some reason computers connected to router B when it is connected via cable X have very slow Internet connection. It is like 5 times slower than what is expected. This is the actual problem I am trying to solve. Interesting facts If a computer is connected to cable X directly instead of through router B the Internet speed is just fine (up to the 50Mbps I get from the ISP). Tested with two computers. I have tried replacing router B with another router C and the problem persists. If I connect router B via another cable to the same ports with the same settings everything seems to work fine and computers connected to router B have quite fast Internet I have tested mainly via Speedtest.net but I have also achieved similar speeds when downloading a file The upload speed is quite higher than the download speed in all cases. Note that my ISP usually has higher upload speed (unless it manages to hit the 50Mbps cap) It seems like the speed when connecting through router B with cable X is reduced 4-5 times no matter what the original speed is. For example via router B I get 10Mbps speed to local servers where I get 50Mbps when connected on router A. If I use a distant server where the ISP is only able to provide 25Mbps I get 4-5Mbps on router B. WiFi is slower than LAN on both routers (which is normal) but the reduced speed is reduced proportionally for WiFi. In addition the upload speed is normally higher from the ISP and it is also reduced proportionally. I have tried two different network configurations. One where I have NAT behind NAT where router B connects to router A via the WAN port and has its own DHCP. Second where router B connects to router A via standard LAN port and has DHCP disabled. In this configuration router B serves as a switch and the Network Gateway for computers connected to router B is the internal IP address of router A. Both configurations work just fine but both manifest the reduced speed issue. pings seem to work just fine As far as I can tell none of the cables is crossed The RJ45 setup for cable X orange orange-white brown brow-white blue blue-white green green-white This is a big problem for me since cable X passes through walls and floors and is very hard to replace. I also may have gotten some of the facts wrong because I am almost going crazy with this issue and testing includes going several floors up and down the staircase. One hypothesis I came up with is that the cable is defective in such a way that the voltage from the router affects its performance. When it is connected to a computer it performs just fine but the router has less power. Related hypothesis includes the cable being affected by electricity cables in the walls when the voltage is low. (I know nothing about electricity) So any ideas what to do, what to test or what the issue may be?

    Read the article

  • Vertical Scrolling In Tile Based XNA Platformer

    - by alec100_94
    I'm making a 2D platformer in XNA 4.0. I have created a working tile engine, which works well for my purposes, and Horizontal Scrolling works flawlessly, however I am having great trouble with Vertical scrolling. I Basically want the camera to scroll up (world to scroll down) when the player reaches a certain Y co-ordinate, and I would also like to automatically scroll back down if coming down, and that co-ordinate is passed. My biggest problem is I have no real way of detecting the direction the player is moving in using only the Y Co-ord. Here Is My Code Code For The Camera Class (which appears to be a very different approach to most camera classes I have seen). using System; using System.Collections.Generic; using System.Linq; using System.Text; using Microsoft.Xna.Framework; namespace Marvin { class Camera : TileEngine { public static bool startReached; public static bool endReached; public static void MoveRight(float speed = 2) { //Moves The Position of Each Tile Right foreach (Tile t in tiles) { if(t!=null) { t.position.X -= speed; } } } public static void MoveLeft(float speed = 2) { //Moves The Position of Each Tile Right foreach (Tile t in tiles) { if(t!=null) { t.position.X += speed; } } } public static void MoveUp(float speed = 2) { foreach (Tile t in tiles) { if(t!=null) { t.position.Y += speed; } } } public static void MoveDown(float speed = 2) { foreach (Tile t in tiles) { if(t!=null) { t.position.Y -= speed; } } } public static void Restrain() { if(tiles.Last().position.X<Main.graphics.PreferredBackBufferWidth-tiles.Last().size.X) { MoveLeft(); endReached = true; } else { endReached = false; } if(tiles[1].position.X>0) { MoveRight(); startReached = true;} else { startReached = false; } } } } Here is My Player Code for Left and Right Scrolling/Moving if (Main.currentKeyState.IsKeyDown(Keys.Right)) { Camera.MoveRight(); if(Camera.endReached) { MoveRight(2); } else { if(marvin.GetRectangle().X!=Main.graphics.PreferredBackBufferWidth-(marvin.GetRectangle().X+marvin.GetRectangle().Width)) { MoveRight(2); Camera.MoveLeft(); } } } if(Main.currentKeyState.IsKeyDown(Keys.Left)) { Camera.MoveLeft(); if(Camera.startReached) { MoveLeft(2); } else { if(marvin.GetRectangle().X!=Main.graphics.PreferredBackBufferWidth-(marvin.GetRectangle().X+marvin.GetRectangle().Width)) { MoveLeft(2); Camera.MoveRight(); } } } Camera.Restrain(); if(marvin.GetRectangle().X>Main.graphics.PreferredBackBufferWidth-marvin.GetRectangle().Width) { MoveLeft(2); } if(marvin.GetRectangle().X<0) { MoveRight(2); } And Here Is My Player Jumping/Falling Code which may cause some conflicts with the vertical camera movement. if (!jumping) { if(!TileEngine.TopOfTileCollidingWith(footBounds)) { MoveDown(5); } else { if(marvin.GetRectangle().Y != TileEngine.LastPlatformStoodOnTop()-marvin.GetRectangle().Height) { float difference = (TileEngine.LastPlatformStoodOnTop()-marvin.GetRectangle().Height) - (marvin.GetRectangle().Y); marvin.SetRectangle(marvin.GetRectangle().X,(int)(marvin.GetRectangle().Y+difference)); armR.SetRectangle(armR.GetRectangle().X,(int)(armR.GetRectangle().Y+difference)); armL.SetRectangle(armL.GetRectangle().X,(int)(armL.GetRectangle().Y+difference)); eyeL.SetRectangle(eyeL.GetRectangle().X,(int)(eyeL.GetRectangle().Y+difference)); eyeR.SetRectangle(eyeR.GetRectangle().X,(int)(eyeR.GetRectangle().Y+difference)); } } } if (Main.currentKeyState.IsKeyDown(Keys.Up) && Main.previousKeyState.IsKeyUp(Keys.Up) && TileEngine.TopOfTileCollidingWith(footBounds)) { jumping = true; } if(jumping) { if(TileEngine.LastPlatformStoodOnTop()>0 && (TileEngine.LastPlatformStoodOnTop() - footBounds.Bottom)<120) { MoveUp(5); } else { jumping = false; } } All player code I have tried for vertical movements has failed, or caused weird results (like falling through platforms), and most have been a variation on the method I described above, hence I have not included it. I would really appreciate some help implementing a simple vertical scrolling into this game, Thanks.

    Read the article

  • After writing SQL statements in MySQL, how to measure the speed / performance of them?

    - by Jian Lin
    I saw something from an "execution plan" article: 10 rows fetched in 0.0003s (0.7344s) How come there are 2 durations shown? What if I don't have large data set yet. For example, if I have only 20, 50, or even just 100 records, I can't really measure how faster 2 different SQL statements compare in term of speed in real life situation? In other words, there needs to be at least hundreds of thousands of records, or even a million records to accurately compares the performance of 2 different SQL statements?

    Read the article

  • Is it worth purchasing Mahout in Action to get up to speed with Mahout, or are there other better sources?

    - by gab
    I'm currently a very casual user of Apache Mahout, and I'm considering purchasing the book Mahout in Action. Unfortunately, I'm having a really hard time getting an idea of how worth it this book is -- and seeing as it's a Manning Early Access Program book (and therefore only currently available as a beta-version e-book), I can't take a look myself in a bookstore. Can anyone recommend this as a good (or less good) guide to getting up to speed with Mahout, and/or other sources that can supplement the Mahout website?

    Read the article

  • How can I replace/speed up a text search query which uses LIKE ?

    - by Jules
    I'm trying to speed up my query... select PadID from Pads WHERE (keywords like '%$search%' or ProgramName like '%$search%' or English45 like '%$search%') AND RemovemeDate = '2001-01-01 00:00:00' ORDER BY VersionAddDate DESC I've done some work already, I have a keywords table so I can add ... PadID IN (SELECT PadID FROM Keywords WHERE word = '$search') ... However its going to be a nightmare to split up the words from English45 and ProgramName into a word table. Any ideas ? EDIT : (also provided actual table names)

    Read the article

  • CSS selectors : should I minimise my use of the class attribute in the HTML or optimise the speed

    - by Laurent Bourgault-Roy
    As I was working on a small website, I decided to use the PageSpeed extension to check if their was some improvement I could do to make the site load faster. However I was quite surprise when it told me that my use of CSS selector was "inefficient". I was always told that you should keep the usage of the class attribute in the HTML to a minimum, but if I understand correctly what PageSpeed tell me, it's much more efficient for the browser to match directly against a class name. It make sense to me, but it also mean that I need to put more CSS classes in my HTML. It also make my .css file a little harder to read. I usually tend to mark my CSS like this : #mainContent p.productDescription em.priceTag { ... } Which make it easy to read : I know this will affect the main content and that it affect something in a paragraph tag (so I wont start to put all sort of layout code in it) that describe a product and its something that need emphasis. However it seem I should rewrite it as .priceTag { ... } Which remove all context information about the style. And if I want to use differently formatted price tag (for example, one in a list on the sidebar and one in a paragraph), I need to use something like that .paragraphPriceTag { ... } .listPriceTag { ... } Which really annoy me since I seem to duplicate the semantic of the HTML in my classes. And that mean I can't put common style in an unqualified .priceTag { ... } and thus I need to replicate the style in both CSS rule, making it harder to make change. (Altough for that I could use multiple class selector, but IE6 dont support them) I believe making code harder to read for the sake of speed has never been really considered a very good practice . Except where it is critical, of course. This is why people use PHP/Ruby/C# etc. instead of C/assembly to code their site. It's easier to write and debug. So I was wondering if I should stick with few CSS classes and complex selector or if I should go the optimisation route and remove my fancy CSS selectors for the sake of speed? Does PageSpeed make over the top recommandation? On most modern computer, will it even make a difference?

    Read the article

  • How can I speed up my Perl regex matching?

    - by est
    I want to capture several text using the following regex: $text_normal = qr{^(\/F\d+) FF (.*?) SCF SF (.*?) MV (\(.*?)SH$}; A sample of the string is like below: my $text = '/F12345 FF FF this is SCF SF really MV (important stuff SH'; Can that be rewritten to speed up the matching?

    Read the article

< Previous Page | 40 41 42 43 44 45 46 47 48 49 50 51  | Next Page >