Search Results

Search found 1148 results on 46 pages for 'capacity'.

Page 44/46 | < Previous Page | 40 41 42 43 44 45 46  | Next Page >

  • Emtel Knowledge Series - Q2/2014

    From Cyber Island to Smart Mauritius Cyber Island? Smart Mauritius? - What is Emtel talking about? "With the majority of the population living in urban environments today, the concept of "Smart Cities" has become an urgent necessity. "Smart Cities" refer to an urban transformation which, by using latest ICT technologies makes cities more efficient. Many Governments are setting out ambitious plans to build the cities of the future based on massive connectivity, high bandwidth communications, intelligent sensors and analysis of huge volumes of data. Various researches have shown four key enablers for smart city success - Government leadership, suitable technology infrastructure, solid public-private partnerships and engaged citizens. It is around these enabling factors that telecoms companies can play a vital role in assisting governments to deliver on the smart city vision." The Emtel Knowledge Series goes in compliance with Emtel's 25th anniversary celebrations throughout the year and the master of ceremony, Kim Andersen, mentioned that there will be more upcoming events on a quarterly base. As a representative of the Mauritius Software Craftsmanship Community (MSCC) there was absolutely no hesitation to join in again. Following my visit to the first Emtel Knowledge Series workshop back in February this year, it was great to have another opportunity to meet and exchange with technology experts. But quite frankly what is it with those buzz words... As far as I remember and how it was mentioned "Cyber Island" is an old initiative from around 2005/2006 which has been refreshed in 2010. It implies the empowerment of Information & Communication Technologies (ICT) as an essential factor of growth by the government here in Mauritius. Actually, the first promotional period of Cyber Island brought me here but that's another story. The venue and its own problems Like last time the event was organised and held at the Conference Hall at Cyber Tower I in Ebene. As I've been working there for some years, I know about the frustrating situation of finding a proper parking. So, does Smart Island include better solutions for the search of parking spaces? Maybe, let's see whether I will be able to answer that question at the end of the article. Anyway, after circling around the tower almost two times, I finally got a decent space to put the car, without risking to get a ticket or damage actually. International speakers and their experience Once again, Emtel did a great job to get international expertise onto the stage to share their experience and vision on this kind of embarkment. Personally, I really appreciated the fact they were speakers of global reach and could provide own-experience knowledge. Johan Gott spoke about the fundamental change that the Swedish government ignited in order to move their society and workers' environment away from heavy industry towards a knowledge-based approach. Additionally, we spoke about the effort and transformation of New York City into a greener and more efficient Smart City. Given modern technology he also advised that any kind of available Big Data should be opened to the general public - this openness would provide a playground for anyone to garner new ideas and most probably solid solutions of which no one else thought about before. Emtel Knowledge Series on moving from Cyber Island to Smart Mauritus Later during the afternoon that exact statement regarding openness to and transparency of government-owned Big Data has been emphasised again by the Danish speaker Kim Andersen and his former colleague Mika Jantunen from Finland. Mika continued to underline the important role of the government to provide a solid foundation for a knowledge-based society and mentioned that Finnish citizens have a constitutional right to broadband connectivity. Next to free higher (tertiary) education Finland already produced a good number of innovations, among them are: First country to grant voting rights to women Free higher education Constitutional right to broadband connectivity Nokia Linux Angry Birds Sauna and others...  General access to internet via broadband and/or mobile connectivity is surely a key factor towards Smart Cities, or better said Smart Mauritius given the area dimensions and size of population. CTO Paul Valette gave the audience a brief overview of the essential role that Emtel will have to move Mauritius forward towards a knowledge-based and innovation-driven environment for its citizen. What I have seen looks really promising and with recently published information that Mauritians have 127% of mobile capacity - meaning more than 1 mobile, smartphone or tablet per person - it will be crucial to have the right infrastructure for these connected devices. How would it be possible to achieve a knowledge-based society? YouTube to the rescue!Seriously, gaining more knowledge will require to have fast access to educational course material as explained by Dr Kaviraj Sukon, General Director of the Open University of Mauritius. According to him a good number of high-profile universities in the world have opened their course libraries to the general public, among them EDX, Coursera and Open University. Nowadays, you're actually able and enabled to learn for and earn a BSc or even MSc certification on your own pace - no need to attend classed on campus. It was really impressive to see the number of available hours - more than enough for a life-long learning experience! {loadposition content_adsense} Networking in the name of MSCC As briefly mentioned above I was about to combine two approaches for this workshop. Of course, getting latest information and updates on Emtel services available, especially for my business here on the west coast of the island, but also to meet and greet new people for the MSCC. And I think it was very positive on both sides. Let me quickly describe some of the key aspects that happened during the day: Met with Arnaud Meslier and Kellie, both Microsoft to swap latest information on IT events. Hereby, I got an invite to Microsoft Windows Phone 8.1 Dev Camp. Got in touch with Arvin Lockee, Emtel to check our options to meet with the data team, and seizing the opportunity to have a visiting tour at the Emtel Data Centre. Had a great chat with Avinash Meetoo, Knowledge 7, Kim Andersen and Mika Jantunen about the situation of teaching and learning in general and specifically in the private sector here in Mauritius. Additionally, a number of various other interesting chats... Once again, I'm catching up on a couple of business cards in order to provide more background information about the MSCC, and to create a better awareness of MSCC within the local IT businesses. There is more to come soon!  Resume of the day The number of attendees during this event has been doubled or even tripled this time. The whole organisation has been improved massively and the combination of presentation and summarizing panel discussions was better than during the previous workshop back in February. Overall, once again a well-organised workshop and I'm already looking forward to join the next workshop in Q3. Update End of July we finally managed to visit the Emtel Data Centre in Arsenal. It was an interesting opportunity for some of our MSCC members.

    Read the article

  • NUMA-aware placement of communication variables

    - by Dave
    For classic NUMA-aware programming I'm typically most concerned about simple cold, capacity and compulsory misses and whether we can satisfy the miss by locally connected memory or whether we have to pull the line from its home node over the coherent interconnect -- we'd like to minimize channel contention and conserve interconnect bandwidth. That is, for this style of programming we're quite aware of where memory is homed relative to the threads that will be accessing it. Ideally, a page is collocated on the node with the thread that's expected to most frequently access the page, as simple misses on the page can be satisfied without resorting to transferring the line over the interconnect. The default "first touch" NUMA page placement policy tends to work reasonable well in this regard. When a virtual page is first accessed, the operating system will attempt to provision and map that virtual page to a physical page allocated from the node where the accessing thread is running. It's worth noting that the node-level memory interleaving granularity is usually a multiple of the page size, so we can say that a given page P resides on some node N. That is, the memory underlying a page resides on just one node. But when thinking about accesses to heavily-written communication variables we normally consider what caches the lines underlying such variables might be resident in, and in what states. We want to minimize coherence misses and cache probe activity and interconnect traffic in general. I don't usually give much thought to the location of the home NUMA node underlying such highly shared variables. On a SPARC T5440, for instance, which consists of 4 T2+ processors connected by a central coherence hub, the home node and placement of heavily accessed communication variables has very little impact on performance. The variables are frequently accessed so likely in M-state in some cache, and the location of the home node is of little consequence because a requester can use cache-to-cache transfers to get the line. Or at least that's what I thought. Recently, though, I was exploring a simple shared memory point-to-point communication model where a client writes a request into a request mailbox and then busy-waits on a response variable. It's a simple example of delegation based on message passing. The server polls the request mailbox, and having fetched a new request value, performs some operation and then writes a reply value into the response variable. As noted above, on a T5440 performance is insensitive to the placement of the communication variables -- the request and response mailbox words. But on a Sun/Oracle X4800 I noticed that was not the case and that NUMA placement of the communication variables was actually quite important. For background an X4800 system consists of 8 Intel X7560 Xeons . Each package (socket) has 8 cores with 2 contexts per core, so the system is 8x8x2. Each package is also a NUMA node and has locally attached memory. Every package has 3 point-to-point QPI links for cache coherence, and the system is configured with a twisted ladder "mobius" topology. The cache coherence fabric is glueless -- there's not central arbiter or coherence hub. The maximum distance between any two nodes is just 2 hops over the QPI links. For any given node, 3 other nodes are 1 hop distant and the remaining 4 nodes are 2 hops distant. Using a single request (client) thread and a single response (server) thread, a benchmark harness explored all permutations of NUMA placement for the two threads and the two communication variables, measuring the average round-trip-time and throughput rate between the client and server. In this benchmark the server simply acts as a simple transponder, writing the request value plus 1 back into the reply field, so there's no particular computation phase and we're only measuring communication overheads. In addition to varying the placement of communication variables over pairs of nodes, we also explored variations where both variables were placed on one page (and thus on one node) -- either on the same cache line or different cache lines -- while varying the node where the variables reside along with the placement of the threads. The key observation was that if the client and server threads were on different nodes, then the best placement of variables was to have the request variable (written by the client and read by the server) reside on the same node as the client thread, and to place the response variable (written by the server and read by the client) on the same node as the server. That is, if you have a variable that's to be written by one thread and read by another, it should be homed with the writer thread. For our simple client-server model that means using split request and response communication variables with unidirectional message flow on a given page. This can yield up to twice the throughput of less favorable placement strategies. Our X4800 uses the QPI 1.0 protocol with source-based snooping. Briefly, when node A needs to probe a cache line it fires off snoop requests to all the nodes in the system. Those recipients then forward their response not to the original requester, but to the home node H of the cache line. H waits for and collects the responses, adjudicates and resolves conflicts and ensures memory-model ordering, and then sends a definitive reply back to the original requester A. If some node B needed to transfer the line to A, it will do so by cache-to-cache transfer and let H know about the disposition of the cache line. A needs to wait for the authoritative response from H. So if a thread on node A wants to write a value to be read by a thread on node B, the latency is dependent on the distances between A, B, and H. We observe the best performance when the written-to variable is co-homed with the writer A. That is, we want H and A to be the same node, as the writer doesn't need the home to respond over the QPI link, as the writer and the home reside on the very same node. With architecturally informed placement of communication variables we eliminate at least one QPI hop from the critical path. Newer Intel processors use the QPI 1.1 coherence protocol with home-based snooping. As noted above, under source-snooping a requester broadcasts snoop requests to all nodes. Those nodes send their response to the home node of the location, which provides memory ordering, reconciles conflicts, etc., and then posts a definitive reply to the requester. In home-based snooping the snoop probe goes directly to the home node and are not broadcast. The home node can consult snoop filters -- if present -- and send out requests to retrieve the line if necessary. The 3rd party owner of the line, if any, can respond either to the home or the original requester (or even to both) according to the protocol policies. There are myriad variations that have been implemented, and unfortunately vendor terminology doesn't always agree between vendors or with the academic taxonomy papers. The key is that home-snooping enables the use of a snoop filter to reduce interconnect traffic. And while home-snooping might have a longer critical path (latency) than source-based snooping, it also may require fewer messages and less overall bandwidth. It'll be interesting to reprise these experiments on a platform with home-based snooping. While collecting data I also noticed that there are placement concerns even in the seemingly trivial case when both threads and both variables reside on a single node. Internally, the cores on each X7560 package are connected by an internal ring. (Actually there are multiple contra-rotating rings). And the last-level on-chip cache (LLC) is partitioned in banks or slices, which with each slice being associated with a core on the ring topology. A hardware hash function associates each physical address with a specific home bank. Thus we face distance and topology concerns even for intra-package communications, although the latencies are not nearly the magnitude we see inter-package. I've not seen such communication distance artifacts on the T2+, where the cache banks are connected to the cores via a high-speed crossbar instead of a ring -- communication latencies seem more regular.

    Read the article

  • Unable to connect to Wireless after installing Ubuntu 12.10

    - by Moulik
    I am using Asus U56E laptop and after installing Ubuntu 12.10 alongside Windows 8, I am unable to connect to the Wireless. I have been trying to solve this problem since two weeks and couldn't solve it. Please help. Any answer would be appreciated. Here are some command-line results. lspci -v | grep -iA 7 network ubuntu@ubuntu:~$ lspci -v | grep -iA 7 network 02:00.0 Network controller: Intel Corporation Centrino Wireless-N + WiMAX 6150 (rev 67) Subsystem: Intel Corporation Centrino Wireless-N + WiMAX 6150 BGN Flags: bus master, fast devsel, latency 0, IRQ 52 Memory at de800000 (64-bit, non-prefetchable) [size=8K] Capabilities: <access denied> Kernel driver in use: iwlwifi Kernel modules: iwlwifi lsmod | grep iwlwifi ubuntu@ubuntu:~$ lsmod | grep iwlwifi iwlwifi 386826 0 mac80211 539908 1 iwlwifi cfg80211 206566 2 iwlwifi,mac80211 ubuntu@ubuntu:~$ dmesg | grep iwlwifi [ 57.846261] iwlwifi: Intel(R) Wireless WiFi Link AGN driver for Linux, in-tree: [ 57.846264] iwlwifi: Copyright(c) 2003-2012 Intel Corporation [ 57.846336] iwlwifi 0000:02:00.0: >pci_resource_len = 0x00002000 [ 57.846338] iwlwifi 0000:02:00.0: >pci_resource_base = ffffc90000c7c000 [ 57.846341] iwlwifi 0000:02:00.0: >HW Revision ID = 0x67 [ 57.846438] iwlwifi 0000:02:00.0: >irq 52 for MSI/MSI-X [ 59.558335] iwlwifi 0000:02:00.0: >loaded firmware version 41.28.5.1 build 33926 [ 59.558514] iwlwifi 0000:02:00.0: >CONFIG_IWLWIFI_DEBUG disabled [ 59.558516] iwlwifi 0000:02:00.0: >CONFIG_IWLWIFI_DEBUGFS enabled [ 59.558517] iwlwifi 0000:02:00.0: >CONFIG_IWLWIFI_DEVICE_TRACING enabled [ 59.558519] iwlwifi 0000:02:00.0: >CONFIG_IWLWIFI_DEVICE_TESTMODE enabled [ 59.558520] iwlwifi 0000:02:00.0: >CONFIG_IWLWIFI_P2P disabled [ 59.558522] iwlwifi 0000:02:00.0: >Detected Intel(R) Centrino(R) Wireless-N + WiMAX 6150 BGN, REV=0x84 [ 59.558583] iwlwifi 0000:02:00.0: >L1 Disabled; Enabling L0S [ 59.569083] iwlwifi 0000:02:00.0: >device EEPROM VER=0x557, CALIB=0x6 [ 59.569085] iwlwifi 0000:02:00.0: >Device SKU: 0x150 [ 59.569087] iwlwifi 0000:02:00.0: >Valid Tx ant: 0x1, Valid Rx ant: 0x3 [ 59.569100] iwlwifi 0000:02:00.0: >Tunable channels: 13 802.11bg, 0 802.11a channels [ 70.208469] iwlwifi 0000:02:00.0: >L1 Disabled; Enabling L0S [ 70.208648] iwlwifi 0000:02:00.0: >Radio type=0x1-0x2-0x0 [ 70.366319] iwlwifi 0000:02:00.0: >L1 Disabled; Enabling L0S [ 70.366470] iwlwifi 0000:02:00.0: >Radio type=0x1-0x2-0x0 sudo lshw -c network ubuntu@ubuntu:~$ sudo lshw -c network *-network description: Wireless interface product: Centrino Wireless-N + WiMAX 6150 vendor: Intel Corporation physical id: 0 bus info: pci@0000:02:00.0 logical name: wlan0 version: 67 serial: 40:25:c2:84:99:c4 width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list ethernet physical wireless configuration: broadcast=yes driver=iwlwifi driverversion=3.5.0-17-generic firmware=41.28.5.1 build 33926 latency=0 link=no multicast=yes wireless=IEEE 802.11bgn resources: irq:52 memory:de800000-de801fff *-network description: Ethernet interface product: AR8151 v2.0 Gigabit Ethernet vendor: Atheros Communications Inc. physical id: 0 bus info: pci@0000:04:00.0 logical name: eth0 version: c0 serial: 54:04:a6:2b:6a:ef capacity: 1Gbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress vpd bus_master cap_list ethernet physical tp 10bt 10bt-fd 100bt 100bt-fd 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=atl1c driverversion=1.0.1.0-NAPI latency=0 link=no multicast=yes port=twisted pair resources: irq:54 memory:dd400000-dd43ffff ioport:a000(size=128) ifconfig ubuntu@ubuntu:~$ ifconfig eth0 Link encap:Ethernet HWaddr 54:04:a6:2b:6a:ef UP BROADCAST MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:0 (0.0 B) TX bytes:0 (0.0 B) lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:176 errors:0 dropped:0 overruns:0 frame:0 TX packets:176 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:14368 (14.3 KB) TX bytes:14368 (14.3 KB) wlan0 Link encap:Ethernet HWaddr 40:25:c2:84:99:c4 UP BROADCAST MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:0 (0.0 B) TX bytes:0 (0.0 B) iwconfig ubuntu@ubuntu:~$ iwconfig eth0 no wireless extensions. lo no wireless extensions. wlan0 IEEE 802.11bgn ESSID:off/any Mode:Managed Access Point: Not-Associated Tx-Power=15 dBm Retry long limit:7 RTS thr:off Fragment thr:off Power Management:off iwlist scan ubuntu@ubuntu:~$ iwlist scan eth0 Interface doesn't support scanning. lo Interface doesn't support scanning. wlan0 No scan results nm-tool ubuntu@ubuntu:~$ nm-tool NetworkManager Tool State: disconnected - Device: eth0 ----------------------------------------------------------------- Type: Wired Driver: atl1c State: unavailable Default: no HW Address: 54:04:A6:2B:6A:EF Capabilities: Carrier Detect: yes Wired Properties Carrier: off - Device: wlan0 ---------------------------------------------------------------- Type: 802.11 WiFi Driver: iwlwifi State: disconnected Default: no HW Address: 40:25:C2:84:99:C4 Capabilities: Wireless Properties WEP Encryption: yes WPA Encryption: yes WPA2 Encryption: yes Wireless Access Points hypeness2: Infra, 00:21:29:DA:08:4F, Freq 2462 MHz, Rate 54 Mb/s, Strength 42 WPA love: Infra, 68:7F:74:17:02:66, Freq 2412 MHz, Rate 54 Mb/s, Strength 19 WPA WPA2 DIRECT-MwSCX-3400Pamela: Infra, 02:15:99:A3:3F:AC, Freq 2412 MHz, Rate 54 Mb/s, Strength 22 WPA2 router: Infra, 1C:AF:F7:D6:76:F3, Freq 2417 MHz, Rate 54 Mb/s, Strength 20 WPA2 wing: Infra, E8:40:F2:34:E4:F7, Freq 2437 MHz, Rate 54 Mb/s, Strength 20 WPA WPA2 132LINKSYS: Infra, 00:1A:70:80:1F:E9, Freq 2437 MHz, Rate 54 Mb/s, Strength 57 WEP VMITTAL: Infra, E0:46:9A:3C:F0:C4, Freq 2412 MHz, Rate 54 Mb/s, Strength 27 WEP HP-Print-10-LaserJet 1025: Infra, 7C:E9:D3:7E:F8:10, Freq 2437 MHz, Rate 54 Mb/s, Strength 59 ACNBB: Infra, 00:26:75:22:A6:2F, Freq 2437 MHz, Rate 54 Mb/s, Strength 20 SATKAIVAL: Infra, 00:18:E7:CE:69:A6, Freq 2412 MHz, Rate 54 Mb/s, Strength 69 WPA WPA2 hypeness: Infra, B8:E6:25:24:C3:B1, Freq 2437 MHz, Rate 54 Mb/s, Strength 54 WPA WPA2 CSNetwork: Infra, BC:14:01:58:C5:88, Freq 2437 MHz, Rate 54 Mb/s, Strength 25 WPA WPA2 tharma: Infra, BC:14:01:E2:06:18, Freq 2412 MHz, Rate 54 Mb/s, Strength 15 WPA WPA2 Active2.4: Infra, 10:6F:3F:0E:F3:8E, Freq 2462 MHz, Rate 54 Mb/s, Strength 17 WPA WPA2 ACNBB: Infra, 00:26:75:58:4E:7A, Freq 2437 MHz, Rate 54 Mb/s, Strength 85 KO: Infra, BC:14:01:2E:AF:A8, Freq 2452 MHz, Rate 54 Mb/s, Strength 22 WPA WPA2 FEAR: Infra, 00:18:4D:C0:BC:58, Freq 2462 MHz, Rate 54 Mb/s, Strength 17 WPA Pamela: Infra, BC:14:01:52:F6:F8, Freq 2412 MHz, Rate 54 Mb/s, Strength 24 WPA WPA2 bvrk2: Infra, 78:CD:8E:7B:3C:79, Freq 2457 MHz, Rate 54 Mb/s, Strength 19 WPA WPA2 BELL030: Infra, D8:6C:E9:17:AF:09, Freq 2462 MHz, Rate 54 Mb/s, Strength 22 WPA2 Desai: Infra, 00:1D:7E:52:FB:C5, Freq 2437 MHz, Rate 54 Mb/s, Strength 14 WEP Sritharan: Infra, BC:14:01:E5:59:78, Freq 2462 MHz, Rate 54 Mb/s, Strength 19 WPA WPA2 PFN: Infra, 00:13:10:8B:CF:45, Freq 2437 MHz, Rate 54 Mb/s, Strength 19 WEP rfkill list all ubuntu@ubuntu:~$ rfkill list all 0: asus-wlan: Wireless LAN Soft blocked: no Hard blocked: no 1: asus-wimax: WiMAX Soft blocked: yes Hard blocked: no 2: phy0: Wireless LAN Soft blocked: no Hard blocked: no so these are some more results sudo modprobe -r iwlwifi ubuntu@ubuntu:~$ sudo modprobe -r iwlwifi sudo modprobe iwlwifi 11n_disable=1 ubuntu@ubuntu:~$ sudo modprobe iwlwifi 11n_disable=1 echo "blacklist asus_wmi" | sudo tee -a /etcmodprobe.d/blacklist.conf ubuntu@ubuntu:~$ echo "blacklist asus_wmi" | sudo tee -a /etc/modprobe.d/blacklist.conf blacklist asus_wmi echo "options iwlwifi 11n_disable=1" | sudo tee /etc/modprobe.d/iwlwifi.conf ubuntu@ubuntu:~$ echo "options iwlwifi 11n_disable=1" | sudo tee /etc/modprobe.d/iwlwifi.conf options iwlwifi 11n_disable=1 sudo modprobe -rfv iwlwifi ubuntu@ubuntu:~$ sudo modprobe -rfv iwlwifi rmmod /lib/modules/3.5.0-17-generic/kernel/drivers/net/wireless/iwlwifi/iwlwifi.ko rmmod /lib/modules/3.5.0-17-generic/kernel/net/mac80211/mac80211.ko rmmod /lib/modules/3.5.0-17-generic/kernel/net/wireless/cfg80211.ko sudo modprobe -v iwlwifi ubuntu@ubuntu:~$ sudo modprobe -v iwlwifi insmod /lib/modules/3.5.0-17-generic/kernel/net/wireless/cfg80211.ko insmod /lib/modules/3.5.0-17-generic/kernel/net/mac80211/mac80211.ko insmod /lib/modules/3.5.0-17-generic/kernel/drivers/net/wireless/iwlwifi/iwlwifi.ko 11n_disable=1

    Read the article

  • laptop crashed: why?

    - by sds
    my linux (ubuntu 12.04) laptop crashed, and I am trying to figure out why. # last sds pts/4 :0 Tue Sep 4 10:01 still logged in sds pts/3 :0 Tue Sep 4 10:00 still logged in reboot system boot 3.2.0-29-generic Tue Sep 4 09:43 - 11:23 (01:40) sds pts/8 :0 Mon Sep 3 14:23 - crash (19:19) this seems to indicate a crash at 09:42 (= 14:23+19:19). as per another question, I looked at /var/log: auth.log: Sep 4 09:17:02 t520sds CRON[32744]: pam_unix(cron:session): session closed for user root Sep 4 09:43:17 t520sds lightdm: pam_unix(lightdm:session): session opened for user lightdm by (uid=0) no messages file syslog: Sep 4 09:24:19 t520sds kernel: [219104.819975] CPU0: Package power limit normal Sep 4 09:43:16 t520sds kernel: imklog 5.8.6, log source = /proc/kmsg started. kern.log: Sep 4 09:24:19 t520sds kernel: [219104.819969] CPU1: Package power limit normal Sep 4 09:24:19 t520sds kernel: [219104.819971] CPU2: Package power limit normal Sep 4 09:24:19 t520sds kernel: [219104.819974] CPU3: Package power limit normal Sep 4 09:24:19 t520sds kernel: [219104.819975] CPU0: Package power limit normal Sep 4 09:43:16 t520sds kernel: imklog 5.8.6, log source = /proc/kmsg started. Sep 4 09:43:16 t520sds kernel: [ 0.000000] Initializing cgroup subsys cpuset Sep 4 09:43:16 t520sds kernel: [ 0.000000] Initializing cgroup subsys cpu I had a computation running until 9:24, but the system crashed 18 minutes later! kern.log has many pages of these: Sep 4 09:43:16 t520sds kernel: [ 0.000000] total RAM covered: 8086M Sep 4 09:43:16 t520sds kernel: [ 0.000000] gran_size: 64K chunk_size: 64K num_reg: 10 lose cover RAM: 38M Sep 4 09:43:16 t520sds kernel: [ 0.000000] gran_size: 64K chunk_size: 128K num_reg: 10 lose cover RAM: 38M Sep 4 09:43:16 t520sds kernel: [ 0.000000] gran_size: 64K chunk_size: 256K num_reg: 10 lose cover RAM: 38M Sep 4 09:43:16 t520sds kernel: [ 0.000000] gran_size: 64K chunk_size: 512K num_reg: 10 lose cover RAM: 38M Sep 4 09:43:16 t520sds kernel: [ 0.000000] gran_size: 64K chunk_size: 1M num_reg: 10 lose cover RAM: 38M Sep 4 09:43:16 t520sds kernel: [ 0.000000] gran_size: 64K chunk_size: 2M num_reg: 10 lose cover RAM: 38M Sep 4 09:43:16 t520sds kernel: [ 0.000000] gran_size: 64K chunk_size: 4M num_reg: 10 lose cover RAM: 38M Sep 4 09:43:16 t520sds kernel: [ 0.000000] gran_size: 64K chunk_size: 8M num_reg: 10 lose cover RAM: 38M Sep 4 09:43:16 t520sds kernel: [ 0.000000] gran_size: 64K chunk_size: 16M num_reg: 10 lose cover RAM: 38M Sep 4 09:43:16 t520sds kernel: [ 0.000000] *BAD*gran_size: 64K chunk_size: 32M num_reg: 10 lose cover RAM: -16M Sep 4 09:43:16 t520sds kernel: [ 0.000000] *BAD*gran_size: 64K chunk_size: 64M num_reg: 10 lose cover RAM: -16M Sep 4 09:43:16 t520sds kernel: [ 0.000000] gran_size: 64K chunk_size: 128M num_reg: 10 lose cover RAM: 0G Sep 4 09:43:16 t520sds kernel: [ 0.000000] gran_size: 64K chunk_size: 256M num_reg: 10 lose cover RAM: 0G Sep 4 09:43:16 t520sds kernel: [ 0.000000] gran_size: 64K chunk_size: 512M num_reg: 10 lose cover RAM: 0G Sep 4 09:43:16 t520sds kernel: [ 0.000000] gran_size: 64K chunk_size: 1G num_reg: 10 lose cover RAM: 0G Sep 4 09:43:16 t520sds kernel: [ 0.000000] *BAD*gran_size: 64K chunk_size: 2G num_reg: 10 lose cover RAM: -1G does this mean that my RAM is bad?! it also says Sep 4 09:43:16 t520sds kernel: [ 2.944123] EXT4-fs (sda1): INFO: recovery required on readonly filesystem Sep 4 09:43:16 t520sds kernel: [ 2.944126] EXT4-fs (sda1): write access will be enabled during recovery Sep 4 09:43:16 t520sds kernel: [ 3.088001] firewire_core: created device fw0: GUID f0def1ff8fbd7dff, S400 Sep 4 09:43:16 t520sds kernel: [ 8.929243] EXT4-fs (sda1): orphan cleanup on readonly fs Sep 4 09:43:16 t520sds kernel: [ 8.929249] EXT4-fs (sda1): ext4_orphan_cleanup: deleting unreferenced inode 658984 ... Sep 4 09:43:16 t520sds kernel: [ 9.343266] EXT4-fs (sda1): ext4_orphan_cleanup: deleting unreferenced inode 525343 Sep 4 09:43:16 t520sds kernel: [ 9.343270] EXT4-fs (sda1): 56 orphan inodes deleted Sep 4 09:43:16 t520sds kernel: [ 9.343271] EXT4-fs (sda1): recovery complete Sep 4 09:43:16 t520sds kernel: [ 9.645799] EXT4-fs (sda1): mounted filesystem with ordered data mode. Opts: (null) does this mean my HD is bad? As per FaultyHardware, I tried smartctl -l selftest, which uncovered no errors: smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.2.0-30-generic] (local build) Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Model Family: Seagate Momentus 7200.4 Device Model: ST9500420AS Serial Number: 5VJE81YK LU WWN Device Id: 5 000c50 0440defe3 Firmware Version: 0003LVM1 User Capacity: 500,107,862,016 bytes [500 GB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 4 Local Time is: Mon Sep 10 16:40:04 2012 EDT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED See vendor-specific Attribute list for marginal Attributes. General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 109) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x103b) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 117 099 034 Pre-fail Always - 162843537 3 Spin_Up_Time 0x0003 100 100 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 571 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 069 060 030 Pre-fail Always - 17210154023 9 Power_On_Hours 0x0032 095 095 000 Old_age Always - 174362787320258 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 571 184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 1 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 061 043 045 Old_age Always In_the_past 39 (0 11 44 26) 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 84 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 20 193 Load_Cycle_Count 0x0032 099 099 000 Old_age Always - 2434 194 Temperature_Celsius 0x0022 039 057 000 Old_age Always - 39 (0 15 0 0) 195 Hardware_ECC_Recovered 0x001a 041 041 000 Old_age Always - 162843537 196 Reallocated_Event_Count 0x000f 095 095 030 Pre-fail Always - 4540 (61955, 0) 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 254 Free_Fall_Sensor 0x0032 100 100 000 Old_age Always - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 4545 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. Googling for the messages proved inconclusive, I can't even figure out whether the messages are routine or catastrophic. So, what do I do now?

    Read the article

  • Ubuntu 12.04 + Wifi not working

    - by user171154
    i'm having problems connecting over wireless. At the moment, I'm using wicd. It seems to get stuck on "Verifying AP association...". Without wicd I can get the connection up and ping the Net - but if I take eth0 down (ifconfig eth0 down), my wireless goes away too (same result if I unplug the wire instead). wicd is the only way I can bring eth0 back (which is the main reason I'm using it) - ifconfig eth0 and/or ifup eth0 do not re-enable the connection (I just discovered it leaves out the gateway. Adding the gateway back in re-enables the connection including wifi; I didn't want to delete the info about wicd above in case it gives someone an idea.) Doing it manually, despite the errors (which it would be nice to also resolve) - allows me to ping the outside world: ifup wlan0 ioctl[SIOCSIWENCODEEXT]: Invalid argument ioctl[SIOCSIWENCODEEXT]: Invalid argument ssh stop/waiting ssh start/running, process 17336 ping -I wlan0 -c 4 8.8.8.8 PING 8.8.8.8 (8.8.8.8) from 192.168.0.12 wlan0: 56(84) bytes of data. 64 bytes from 8.8.8.8: icmp_req=1 ttl=43 time=48.8 ms 64 bytes from 8.8.8.8: icmp_req=2 ttl=43 time=47.9 ms 64 bytes from 8.8.8.8: icmp_req=3 ttl=43 time=48.7 ms 64 bytes from 8.8.8.8: icmp_req=4 ttl=43 time=53.2 ms --- 8.8.8.8 ping statistics --- 4 packets transmitted, 4 received, 0% packet loss, time 3003ms rtt min/avg/max/mdev = 47.975/49.711/53.235/2.063 ms # iwconfig lo no wireless extensions. wlan0 IEEE 802.11bgn ESSID:"TPLINK" Mode:Managed Frequency:2.427 GHz Access Point: 64:66:xx:xx:xx:22 Bit Rate=108 Mb/s Tx-Power=27 dBm Retry long limit:7 RTS thr:off Fragment thr:off Encryption key:off Power Management:off Link Quality=70/70 Signal level=-39 dBm Rx invalid nwid:0 Rx invalid crypt:0 Rx invalid frag:0 Tx excessive retries:0 Invalid misc:3 Missed beacon:0 bus info: pci@0000:03:00.0 logical name: wlan0 version: 01 serial: f0:7d:68:c1:b4:13 width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix bus_master cap_list ethernet physical wireless configuration: broadcast=yes driver=ath9k driverversion=3.2.0-67-generic-pae firmware=N/A latency=0 link=no multicast=yes wireless=IEEE 802.11bgn resources: irq:17 memory:dfbf0000-dfbfffff ip route default via 192.168.0.1 dev eth0 default via 192.168.0.1 dev wlan0 metric 100 169.254.0.0/16 dev wlan0 scope link metric 1000 192.168.0.0/24 dev eth0 proto kernel scope link src 192.168.0.102 192.168.0.0/24 dev wlan0 proto kernel scope link src 192.168.0.12 (For the record, I have no idea what the 169.254.0.0 address is doing there.) uname -a 3.2.0-67-generic-pae #101-Ubuntu SMP Tue Jul 15 18:04:54 UTC 2014 i686 i686 i386 GNU/Linux lshw -C network *-network description: Ethernet interface product: NetXtreme BCM5751 Gigabit Ethernet PCI Express vendor: Broadcom Corporation physical id: 0 bus info: pci@0000:02:00.0 logical name: eth0 version: 01 serial: 00:11:11:59:fc:09 size: 100Mbit/s capacity: 1Gbit/s width: 64 bits clock: 33MHz capabilities: pm vpd msi pciexpress bus_master cap_list ethernet physical tp 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=tg3 driverversion=3.121 duplex=full firmware=5751-v3.23a ip=192.168.0.102 latency=0 link=yes multicast=yes port=twisted pair speed=100Mbit/s resources: irq:16 memory:dfcf0000-dfcfffff *-network description: Wireless interface product: AR5418 Wireless Network Adapter [AR5008E 802.11(a)bgn] (PCI-Express) vendor: Qualcomm Atheros physical id: 0 /etc/network/interfaces # interfaces(5) file used by ifup(8) and ifdown(8) auto lo iface lo inet loopback source /etc/network/interfaces.eth0 source /etc/network/interfaces.wlan0 /etc/network/interfaces.eth0 #Main Interface auto eth0 iface eth0 inet static address 192.168.0.102 netmask 255.255.255.0 gateway 192.168.0.1 /etc/network/interfaces.wlan0 auto wlan0 iface wlan0 inet static address 192.168.0.12 gateway 192.168.0.1 dns-nameservers 192.168.0.1 8.8.8.8 netmask 255.255.255.0 wpa-driver wext wpa-ssid TPLINK wpa-ap-scan 1 wpa-proto RSN wpa-pairwise CCMP wpa-group CCMP wpa-key-mgmt WPA-PSK wpa-psk dca1badb5fd4e9axxx4xxdaaxxfa91xx610bxx6a7d57ef67af9809dxx6af42e39 /etc/wpa_supplicant.conf ctrl_interface=/var/run/wpa_supplicant network={ ssid="TPLINK" psk="my password" key_mgmt=WPA-PSK proto=RSN pairwise=CCMP group=CCMP } ifdown eth0 ifdown: interface eth0 not configured ifconfig eth0 Link encap:Ethernet HWaddr 00:11:xx:xx:xx:09 inet addr:192.168.0.102 Bcast:192.168.0.255 Mask:255.255.255.0 inet6 addr: fe80::211:11ff:fe59:fc09/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:213690 errors:0 dropped:0 overruns:0 frame:0 TX packets:155266 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:220057808 (220.0 MB) TX bytes:21137696 (21.1 MB) Interrupt:16 lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:196412 errors:0 dropped:0 overruns:0 frame:0 TX packets:196412 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:153270697 (153.2 MB) TX bytes:153270697 (153.2 MB) wlan0 Link encap:Ethernet HWaddr f0:7d:xx:xx:xx:13 inet addr:192.168.0.12 Bcast:192.168.0.255 Mask:255.255.255.0 inet6 addr: fe80::f27d:68ff:fec1:b413/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:11335 errors:0 dropped:0 overruns:0 frame:0 TX packets:7287 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:2563290 (2.5 MB) TX bytes:855746 (855.7 KB) ifconfig eth0 down ifconfig eth0 Link encap:Ethernet HWaddr 00:xx:xx:xx:xx:09 inet addr:192.168.0.102 Bcast:192.168.0.255 Mask:255.255.255.0 inet6 addr: fe80::211:11ff:fe59:fc09/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:2 errors:0 dropped:0 overruns:0 frame:0 TX packets:1 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:192 (192.0 B) TX bytes:94 (94.0 B) Interrupt:16 lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:196418 errors:0 dropped:0 overruns:0 frame:0 TX packets:196418 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:153270871 (153.2 MB) TX bytes:153270871 (153.2 MB) wlan0 Link encap:Ethernet HWaddr f0:7d:xx:xx:xx:13 inet addr:192.168.0.12 Bcast:192.168.0.255 Mask:255.255.255.0 inet6 addr: fe80::f27d:68ff:fec1:b413/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:11359 errors:0 dropped:0 overruns:0 frame:0 TX packets:7293 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:2565482 (2.5 MB) TX bytes:856363 (856.3 KB) ip route default via 192.168.0.1 dev wlan0 metric 100 169.254.0.0/16 dev wlan0 scope link metric 1000 192.168.0.0/24 dev wlan0 proto kernel scope link src 192.168.0.12 192.168.0.0/24 dev eth0 proto kernel scope link src 192.168.0.102 ping -I wlan0 -c 4 8.8.8.8 PING 8.8.8.8 (8.8.8.8) from 192.168.0.12 wlan0: 56(84) bytes of data. --- 8.8.8.8 ping statistics --- 4 packets transmitted, 0 received, 100% packet loss, time 3024ms ping -I eth0 -c 3 router PING router (192.168.0.1) from 192.168.0.102 eth0: 56(84) bytes of data. --- router ping statistics --- 3 packets transmitted, 0 received, 100% packet loss, time 2015ms ping -I wlan0 -c 3 router PING router (192.168.0.1) from 192.168.0.12 wlan0: 56(84) bytes of data. --- router ping statistics --- 3 packets transmitted, 0 received, 100% packet loss, time 2014ms Let me know if you need more info. Thank you in advance.

    Read the article

  • Wireless networks are not detected at start up in Ubuntu 12.04

    - by Kanhaiya Mishra
    I have recently (three four days ago) installed Ubuntu 12.04 via windows installer i.e. wubi.exe. After the installation completed wireless and Ethernet were both working well. But after restart wireless networks didn't show up while in the network manager both networking and wireless were enabled. Though sometimes after boot it did show the networks available but very rarely. So I went through various posts regarding wireless issues in Ubuntu 12.04 and tried so many things but ended up in nothing satisfactory. I have Broadcom 4313 LAN network controller and brcmsmac driver. Then relying on some suggestions I tried to install bcm-wl driver but couldn't install due to some error in jockeyl.log file. Then i tried fresh installation of the same driver but still could resolve the startup issues with wireless. Then again I reinstalled Ubuntu inside windows using wubi installer. This time again same problem occurred after boot. But this time I successfully installed wl driver before disturbing file-system files of Ubuntu. But again the same issue. This time I noticed some new things: If I inserted Ethernet/LAN cable before startup then wireless networks are available and of course LAN(wired) networks also work. but if i don't plug in cable before startup and then plug it after startup then it didn't detect Ethernet network neither wireless. So I haven't noticed it before that LAN along with wifi also doesn't work after startup. But if i suspend the session and make it sleep and again login then it worked. I tried it every time that WLAN worked perfectly. But still i m unable to resolve that startup problem. Each time i boot first I have to suspend it once then only networks are available. It irritates me each time i reboot/boot my lappy. So please help out of this problem. Any ideas/help regarding this issue would be highly appreciated. Some of the commands that i run gave following results: # lspci 00:00.0 Host bridge: Intel Corporation Core Processor DRAM Controller (rev 12) 00:02.0 VGA compatible controller: Intel Corporation Core Processor Integrated Graphics Controller (rev 12) 00:16.0 Communication controller: Intel Corporation 5 Series/3400 Series Chipset HECI Controller (rev 06) 00:1a.0 USB controller: Intel Corporation 5 Series/3400 Series Chipset USB2 Enhanced Host Controller (rev 06) 00:1b.0 Audio device: Intel Corporation 5 Series/3400 Series Chipset High Definition Audio (rev 06) 00:1c.0 PCI bridge: Intel Corporation 5 Series/3400 Series Chipset PCI Express Root Port 1 (rev 06) 00:1c.1 PCI bridge: Intel Corporation 5 Series/3400 Series Chipset PCI Express Root Port 2 (rev 06) 00:1c.5 PCI bridge: Intel Corporation 5 Series/3400 Series Chipset PCI Express Root Port 6 (rev 06) 00:1d.0 USB controller: Intel Corporation 5 Series/3400 Series Chipset USB2 Enhanced Host Controller (rev 06) 00:1e.0 PCI bridge: Intel Corporation 82801 Mobile PCI Bridge (rev a6) 00:1f.0 ISA bridge: Intel Corporation Mobile 5 Series Chipset LPC Interface Controller (rev 06) 00:1f.2 SATA controller: Intel Corporation 5 Series/3400 Series Chipset 6 port SATA AHCI Controller (rev 06) 00:1f.3 SMBus: Intel Corporation 5 Series/3400 Series Chipset SMBus Controller (rev 06) 00:1f.6 Signal processing controller: Intel Corporation 5 Series/3400 Series Chipset Thermal Subsystem (rev 06) 03:00.0 Network controller: Broadcom Corporation BCM4313 802.11b/g/n Wireless LAN Controller (rev 01) 04:00.0 Ethernet controller: Atheros Communications Inc. AR8152 v1.1 Fast Ethernet (rev c1) ff:00.0 Host bridge: Intel Corporation Core Processor QuickPath Architecture Generic Non-core Registers (rev 02) ff:00.1 Host bridge: Intel Corporation Core Processor QuickPath Architecture System Address Decoder (rev 02) ff:02.0 Host bridge: Intel Corporation Core Processor QPI Link 0 (rev 02) ff:02.1 Host bridge: Intel Corporation Core Processor QPI Physical 0 (rev 02) ff:02.2 Host bridge: Intel Corporation Core Processor Reserved (rev 02) ff:02.3 Host bridge: Intel Corporation Core Processor Reserved (rev 02) # sudo lshw -C network *-network description: Wireless interface product: BCM4313 802.11b/g/n Wireless LAN Controller vendor: Broadcom Corporation physical id: 0 bus info: pci@0000:03:00.0 logical name: eth1 version: 01 serial: 70:f1:a1:49:b6:ab width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list ethernet physical wireless configuration: broadcast=yes driver=wl0 driverversion=5.100.82.38 ip=192.168.1.7 latency=0 multicast=yes wireless=IEEE 802.11 resources: irq:17 memory:f0500000-f0503fff *-network description: Ethernet interface product: AR8152 v1.1 Fast Ethernet vendor: Atheros Communications Inc. physical id: 0 bus info: pci@0000:04:00.0 logical name: eth0 version: c1 serial: b8:ac:6f:6b:f7:4a capacity: 100Mbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress vpd bus_master cap_list ethernet physical tp 10bt 10bt-fd 100bt 100bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=atl1c driverversion=1.0.1.0-NAPI firmware=N/A latency=0 link=no multicast=yes port=twisted pair resources: irq:44 memory:f0400000-f043ffff ioport:2000(size=128) # lsmod | grep wl wl 2568210 0 lib80211 14381 2 lib80211_crypt_tkip,wl # sudo iwlist eth1 scanning eth1 Scan completed : Cell 01 - Address: 30:46:9A:85:DA:9A ESSID:"BH DASHIR 2" Mode:Managed Frequency:2.462 GHz (Channel 11) Quality:4/5 Signal level:-60 dBm Noise level:-98 dBm IE: IEEE 802.11i/WPA2 Version 1 Group Cipher : CCMP Pairwise Ciphers (1) : CCMP Authentication Suites (1) : PSK IE: Unknown: DD7F0050F204104A00011010440001021041000100103B000103104700109AFE7D908F8E2D381860668BA2E8D8771021000D4E4554474541522C20496E632E10230009574752363134763130102400095747523631347631301042000538333235381054000800060050F204000110110009574752363134763130100800020084 Encryption key:on Bit Rates:1 Mb/s; 2 Mb/s; 5.5 Mb/s; 11 Mb/s; 18 Mb/s 24 Mb/s; 36 Mb/s; 54 Mb/s; 6 Mb/s; 9 Mb/s 12 Mb/s; 48 Mb/s Cell 02 - Address: C0:3F:0E:EB:45:14 ESSID:"BH DASHIR 3" Mode:Managed Frequency:2.462 GHz (Channel 11) Quality:2/5 Signal level:-71 dBm Noise level:-98 dBm IE: IEEE 802.11i/WPA2 Version 1 Group Cipher : CCMP Pairwise Ciphers (1) : CCMP Authentication Suites (1) : PSK IE: Unknown: DD7F0050F204104A00011010440001021041000100103B00010310470010F3C9BBE499D140540F530E7EBEDE2F671021000D4E4554474541522C20496E632E10230009574752363134763130102400095747523631347631301042000538333235381054000800060050F204000110110009574752363134763130100800020084 Encryption key:on Bit Rates:1 Mb/s; 2 Mb/s; 5.5 Mb/s; 11 Mb/s; 18 Mb/s 24 Mb/s; 36 Mb/s; 54 Mb/s; 6 Mb/s; 9 Mb/s 12 Mb/s; 48 Mb/s Cell 03 - Address: A0:21:B7:A8:2F:C0 ESSID:"BH DASHIR 4" Mode:Managed Frequency:2.422 GHz (Channel 3) Quality:1/5 Signal level:-86 dBm Noise level:-98 dBm IE: IEEE 802.11i/WPA2 Version 1 Group Cipher : CCMP Pairwise Ciphers (1) : CCMP Authentication Suites (1) : PSK IE: Unknown: DD8B0050F204104A0001101044000102103B0001031047001000000000000010000000A021B7A82FC01021000D4E6574676561722C20496E632E10230009574E523130303076321024000456324831104200046E6F6E651054000800060050F20400011011001B574E5231303030763228576972656C6573732041502D322E344729100800020086103C000103 Encryption key:on Bit Rates:1 Mb/s; 2 Mb/s; 5.5 Mb/s; 11 Mb/s; 6 Mb/s 9 Mb/s; 12 Mb/s; 18 Mb/s; 24 Mb/s; 36 Mb/s 48 Mb/s; 54 Mb/s

    Read the article

  • Symantec Protection Suite and System Recovery 2011 Desktop Edition

    - by rihatum
    I am re-posting this as my previous question was being treated as if I am "Shopping or seeking Product Recommendations" even though I was NOT - BTW they have deleted my comments too which were not offensive in nature. anyway - I have re-phrased some parts of my question and I hope SF Admins "Do Not Modify / Edit" this one - will be most grateful for that. I have a lot of respect for the People who visit this SITE and help others ! Just To clarify : Just to go by SF rules - I am not seeking someone to Design this solution, I am simply seeking real world examples, experiences, technical expert opinions / suggestions, any tips or tricks they may have or any problems they may have faced while doing something similar above with these products. I am also not asking for Capacity Planning for Storage, We have done some research and I am seeking Expert Assurance / Suggestions. We (our company) are planning to deploy Symantec Endpoint Protection and Symantec Desktop Recovery 2011 Desktop Edition to our 3000 - 4000 workstations (Windows7 32 and 64) with a few 100s with Windows XP 32/64 Bit. I have read the implementation guide for SEP and have read tech-notes for Desktop Recovery 2011. Our team have planned to deploy this as follows : 1 x dedicated SQL 2008R2 for Symantec Endpoint Protection (Instead of using the Embedded Database) 1 x Dedicated SQL 2008R2 for Symantec Desktop Recovery 2011 (Instead of using the Embedded Database) 1 x Dedicated W2K8 R2 Box for the SEPM (Symantec Endpoint Protection Manager - Mgmt. APP) 1 x Dedicated W2K8 R2 Box for the Symantec Desktop Recovery 2011 Management Application Agent Deployment : As per Symantec Documentation for both of the above, an agent can be pushed via the Mgmt. Application (provided no firewalls are blocking ports required etc. - we have Windows firewall disabled already). Server Hardware : Per SQL Server : 16GB RAM + SAS DISKS + Dual XEON, RAID-10 for the SQL DB or I can always mount a LUN from our existing Hitachi or EMC SAN. SEPM Server : 16GB RAM + SAS DISKS + DUAL XEON System Recovery MGMT SERVER : 16GB RAM + SAS DISKS + DUAL XEON Above is the initial plan we have for 3000 - 4000 client workstation (Windows) Now my Questions :-) a) If we had these users distributed amongst two sites with AD DC / GC in each site, How would I restrict SEPM and Desktop Mgmt. solution to only check for users in their respective site ? b) At present all users are under one building but we are going to move some dept. to a new location (with dedicated connectivity), How would we control which SEPM / MGMT Server is responsible for which site ? c) We have netbackup in our environment backing up other servers, I am planning to protect these 4 (2 x SQL, 1 x SEPM, 1 x System Recovery Mgmt. Server) via netbackup or I can use System recovery 2011 server edition on all 4 of these boxes as well. (License is not an issue as we have the complete symantec portfolio included in our license). d) Now - Saving Desktop backups - What strategies have you implemented ? Any best practice recommendation for a large user base ? I was thinking to either mount a LUN from our Hitachi SAN on the Symantec Recovery Server itself or backup to the users hard drive locally and then copy it over to a network location ? Suggestions welcome :-) If you have anything to add / correct - that will be really helpful before diving into the actual implementation phase. Will be most grateful with your suggestions, recommendations and corrections with above - Many Thanks !

    Read the article

  • Let your Signature Experience drive IT-decision making

    - by Tania Le Voi
    Today’s CIO job description:  ‘’Align IT infrastructure and solutions with business goals and objectives ; AND while doing so reduce costs; BUT ALSO, be innovative, ensure the architectures are adaptable and agile as we need to act today on the changes that we may request tomorrow.”   Sound like an unachievable request? The fact is, reality dictates that CIO’s are put under this type of pressure to deliver more with less. In a past career phase I spent a few years as an IT Relationship Manager for a large Insurance company. This is a role that we see all too infrequently in many of our customers, and it’s a shame.  The purpose of this role was to build a bridge, a relationship between IT and the business. Key to achieving that goal was to ensure the same language was being spoken and more importantly that objectives were commonly understood - hence service and projects were delivered to time, to budget and actually solved the business problems. In reality IT and the business are already married, but the relationship is most often defined as ‘supplier’ of IT rather than a ‘trusted partner’. To deliver business value they need to understand how to work together effectively to attain this next level of partnership. The Business cannot compete if they do not get a new product to market ahead of the competition, or for example act in a timely manner to address a new industry problem such as a legislative change. An even better example is when the Application or Service fails and the Business takes a hit by bad publicity, being trending topics on social media and losing direct revenue from online channels. For this reason alone Business and IT need the alignment of their priorities and deliverables now more than ever! Take a look at Forrester’s recent study that found ‘many IT respondents considering themselves to be trusted partners of the business but their efforts are impaired by the inadequacy of tools and organizations’.  IT Meet the Business; Business Meet IT So what is going on? We talk about aligning the business with IT but the reality is it’s difficult to do. Like any relationship each side has different goals and needs and language can be a barrier; business vs. technology jargon! What if we could translate the needs of both sides into actionable information, backed by data both sides understand, presented in a meaningful way?  Well now we can with the Business-Driven Application Management capabilities in Oracle Enterprise Manager 12cR2! Enterprise Manager’s Business-Driven Application Management capabilities provide the information that IT needs to understand the impact of its decisions on business criteria.  No longer does IT need to be focused solely on speeds and feeds, performance and throughput – now IT can understand IT’s impact on business KPIs like inventory turns, order-to-cash cycle, pipeline-to-forecast, and similar.  Similarly, now the line of business can understand which IT services are most critical for the KPIs they care about. There are a good deal of resources on Oracle Technology Network that describe the functionality of these products, so I won’t’ rehash them here.  What I want to talk about is what you do with these products. What’s next after we meet? Where do you start? Step 1:  Identify the Signature Experience. This is THE business process (or set of processes) that is core to the business, the one that drives the economic engine, the process that a customer recognises the company brand for, reputation, the customer experience, the process that a CEO would state as his number one priority. The crème de la crème of your business! Once you have nailed this it gets easy as Enterprise Manager 12c makes it easy. Step 2:  Map the Signature Experience to underlying IT.  Taking the signature experience, map out the touch points of the components that play a part in ensuring this business transaction is successful end to end, think of it like mapping out a critical path; the applications, middleware, databases and hardware. Use the wealth of Enterprise Manager features such as Systems, Services, Business Application Targets and Business Transaction Management (BTM) to assist you. Adding Real User Experience Insight (RUEI) into the mix will make the end to end customer satisfaction story transparent. Work with the business and define meaningful key performance indicators (KPI’s) and thresholds to enable you to report and action upon. Step 3:  Observe the data over time.  You now have meaningful insight into every step enabling your signature experience and you understand the implication of that experience on your underlying IT.  Watch if for a few months, see what happens and reconvene with your business stakeholders and set clear and measurable targets which can re-define service levels.  Step 4:  Change the information about which you and the business communicate.  It’s amazing what happens when you and the business speak the same language.  You’ll be able to make more informed business and IT decisions. From here IT can identify where/how budget is spent whether on the level of support, performance, capacity, HA, DR, certification etc. IT SLA’s no longer need be focused on metrics such as %availability but structured around business process requirements. The power of this way of thinking doesn’t end here. IT staff get to see and understand how their own role contributes to the business making them accountable for the business service. Take a step further and appraise your staff on the business competencies that are linked to the service availability. For the business, the language barrier is removed by producing targeted reports on the signature experience core to the business and therefore key to the CEO. Chargeback or show back becomes easier to justify as the ‘cost of day per outage’ can be more easily calculated; the business will be able to translate the cost to the business to the cost/value of the underlying IT that supports it. Used this way, Oracle Enterprise Manager 12c is a key enabler to a harmonious relationship between the end customer the business and IT to deliver ultimate service and satisfaction. Just engage with the business upfront, make the signature experience visible and let Enterprise Manager 12c do the rest. In the next blog entry we will cover some of the Enterprise Manager features mentioned to enable you to implement this new way of working.  

    Read the article

  • OS8- AK8- The bad news...

    - by Steve Tunstall
    Ok I told you I would give you the bad news of AK8 to go along with all the cool new stuff, so here it is. It's not that bad, really, just things you need to be aware of. First, the 2013.1 code is being called OS8, AK8 and 2013.1 by different people. I mean different people INSIDE Oracle!! It was supposed to be easy, but it never is. So for the rest of this blog entry, I'm calling it AK8. AK8 is not compatible with the 7x10 series. Ever. The 7x10 series is not supported with AK8, and if you try to upgrade one, it will fail at the healthcheck. All 7x20 series, all of them regardless of age, are supported with AK8. Drive trays. Let's talk about drive trays and SAS cards. The older drive trays for the 7x20 series were called the "Riverwalk 2" or "DS2" trays. They were technically the "J4410" series JBODs that Sun used to sell a la carte before we stopped selling JBODs. Don't get me started on that, it still makes me mad. We used these for many years, and you can still buy them right now until December 15th, 2013, when they will no longer be sold. The DS2 tray only came as a 4u, 24 drive shelf. It held 3.5" drives, and you had a choice of 2TB, 3TB, 300GB or 600GB drives. The SAS HBA in the 7x20 series was called a "Thebe" card, with a part # of 7105394. The 7420, for example, came standard with two of these "Thebe" cards for connecting to the disk trays. Two Thebe cards could handle up to 12 trays, so one would add two more cards to go to 24 trays, or have up to six Thebe cards to handle 36 trays. This card was for external SAS only. It did not connect to the internal OS drives or the Readzillas, both of which used the internal SCSI controller of the server. These Riverwalk 2 trays ARE supported with AK8. You can upgrade your older 7420 or 7320, no problem, as-is. The much older Riverwalk 1 trays or J4400 trays are NOT supported by AK8. However, they were only used by the 7x10 series, and we already said that the 7x10 series was not supported. Here's where it gets tricky. Since last January, we have been selling the new style disk trays. We call them the "DE2-24P" and the "DE2-24C" trays. The "C" tray is for capacity drives, which are 3.5" 3TB or 4TB drives. The "P" trays are for performance drives, which are 2.5" 300GB and 900GB drives. These trays are NOT Riverwalk 2 trays, even though the "C" series may kind of look like it. Different manufacturer and different firmware. They are not new. Like I said, we've been selling them with the 7x20 series since last January. They are the only disk trays we will be selling going forward. Of course, AK8 supports them. So what's the problem? The problem is going to be for people who have to mix drive trays. Remember, your older 7x20 series has Thebe SAS2 HBAs. These have 2 SAS ports per card.  The new ZS3-2 and ZS3-4 systems, however, have the new "Thebe2" SAS2 HBAs. These Thebe2 cards have 4 ports per card. This is very cool, as we can now do more SAS channels with less cards. Instead of needing 4 SAS cards to grow to 24 trays like we did with the old Thebe cards, I can now do 24 trays with only 2 Thebe2 cards. This means more IO slots for fun things like Infiniband and 10G. So far, so good, right? These Thebe2 cards work with any disk tray. You can even mix older DS2 trays with the newer DE2 trays in the same system, as long as you have Thebe2 cards. Ah, there's your problem. You don't have Thebe2 cards in your old 7420, do you? Well, I told you the bad news wasn't that bad, right? We can take out your Thebe cards and replace them with Thebe2. You can then plug your older DS2 trays right back in, and also now get newer DE2 trays going forward. However, it's important that the trays are on different SAS channels. You can mix them in the same system, but not on the same channel. Ask your local SC if you need help with the new cable layout. By the way, the new ZS3-2 and ZS3-4 systems also include a new IO card called "Erie" cards. These are for INTERNAL SAS to the OS drives and the Readzillas. So those are now SAS2 instead of SATA like the older models. Yes, the Erie card uses an IO slot, but that's OK, because the Thebe2 cards allow us to use less SAS HBAs to grow the system, right? That's it. Not too much bad news and really not that bad. AK8 does not support the 7x10 series, and you may need new Thebe2 cards in your older systems if you want to add on newer DE2 trays. I think we can all agree that there are worse things out there. Like our Congress.   Next up.... More good news and cool AK8 tricks. Such as virtual NICS. 

    Read the article

  • File server share access intermittent/slow/machine unstable: win2k8r2

    - by Jack B.
    I have a file server running Win2k8R2 on an older HP DL380G4. It has nothing set up on it other than file sharing. All drivers/firmware/updates installed. The file server is used as a dump for a bunch of test machines - so essentially a lot of small files are being written to it. It was working fine until it started showing the following symptoms: Shares became either very slow/intermittent or could not access them at all. Logging in the the server, you could use it like normal but windows would start freezing and eventually you had to hard reboot it because nothing was responsive. After rebooting, it would work fine for 20min-2hours and then degrade into this broken state again. Some info after investigation: HP Raid Config utility shows the Raid array as functioning properly (RAID5 btw). Event log shows a bunch of DoS attacks from the test machines, saying it has disconnected the connection a. AFAIK (not part of my job) the test machines haven't changed the way they log information to this server or the amount of them hasn't increased. b. Nothing is infected, this server was scanned fully, and the test machines are re-imaged almost daily. Nothing in performance monitor shows as anything being pegged at maximum (CPU/HD/Network/RAM) I installed MS Network Monitor and it is showing a lot of traffic The server was using one gigabit Ethernet connection, I connected the second one as well with the same results. Forgot to add - one of the commonly written to dirs on the share has over 16k subdirs in it, with a crapton of small files within those dirs. Some of the OS instability was slow access to the drive which has this directory - perfmon doesn't show much activity on the HD though so I'm not sure if this crowded dir is the cause. Here is one important fact: I ran into this issue 2-3 months ago, couldn't figure it out, but I had a spare identical machine so I swapped them out (thought it was related to the machine), and now I have the same issue. Also, the computer will be stable if I turn off file sharing. So is the server just getting DoS'd by the test machines? I've never dealt with such an issue. Is instability in the server's OS common when getting DoS'd? Is there anything I can do to confirm this before telling the owners of the test machines to optimize their traffic? (I'm not sure what they'll be able to do). Is there something within Win2k8R2 that can balance the traffic across the two NICs? Any help would be appreciated. Update: Another thought - the drive with the share is RAID5 across 6 SCSI320 300GB HDs. They are near full capacity about 100GB from 1TB left. Could the amount of tiny files could be causing some weirdness with the parity in this array? I think I've read something about this in the past but I'm no expert on RAID.

    Read the article

  • Using different SSDs types (not only SATA based) as system drive

    - by Hubert Kario
    Currently I have a Thinkpad X61s and want to make it both a bit faster and a bit more power efficient. For that reason I thought that adding SSD drive would make most sense. Unfortunately, because of financial reasons, buying SSD of over 200GB capacity is out of reach for me (not only it would be worth more than the rest of the laptop, but also I currently have a 500GB drive in it, so even such a drive would be kind of a downgrade for me). During preliminary testing with a cheap Transcend 4GB Class 6 (14MiB/s streaming, 9MiB/s random read) card I experienced boot times to be reduced by half so putting the OS only on it would already would be an improvement. Unfortunately, my system now is about 11GiB in size so anything less than 16GB would be constraining. In this laptop I can connect additional drives on at least 5 different ways: using SATA-ATA converter caddy in the X6 Ultrabase using internal mini PCIe slot using integrated SDHC slot using CardBus (a.k.a PCMCIA or PC Card) slot using USB Thankfully, because I use only Linux on this PC the bootability of them is irrelevant as I can put the /boot partition on internal HDD and / on any of the above mentioned Flash memories (as I already did for the SDHC test). From what I was able to research and from my own experience those options come with rather big downsides or other problems: SATA-ATA caddy It has three downsides: I have to carry the Ultrabse with me at all times (it's not really inconvenient, but those grams do add) and couldn't disconnect it when I want to disconnect the battery It makes the bay unusable for the optical drive and occasional quick access to other hard drives the only caddies I could buy have rather flaky controllers in them so putting my OS on it would hamper its stability Internal mini PCIe slot This would be an ideal solution, if only I could find real PCIe SSDs, not only devices that could talk only SATA or ATA over PCIe mechanical connection (the ones used in Dell Mini or Asus EEE). Theoretically Samsung did release such devices but I couldn't find them in retail anywhere. Integrated SDHC slot It's a nice solution with a single drawback: the fastest 16GB SDHC card on the market can only do around 35MiB/s read and 15MiB/s write while still costing like a normal 40GB SATA SSD that's 10 times faster. Not really cost-effective. CardBus (a.k.a PCMCIA or PC Card) slot Those cards are much faster than the SDHC option (there are ones that can do well over 50MiB/s read in benchmarks) and from what I could find the PCMCIA controller in my laptop does support UDMA so it should be able to deliver comparable speeds. They still cost similarly to SD cards but at least they provide streaming performance comparable to my current HDD. USB That's the worst option. Not only is it limited to 20-30MiB/s by the interface itself the drive would stick out of the laptop so it's a big no no. The question As such I think that going the "CF in a CardBus adapter" route will be the best option. My question is: did anyone try using CF cards in CardBus adapters as system drives with Linux on Thinkpad laptops? Laptops in general? What was the real-world performance? I don't have any CF cards so I can't check how well does it work with suspend/resume, or whatever it's easy to make it work in initramfs (I'm using ArchLinux and SD card was trivial — add 3 modules in single config line and rebuilding initramfs) so any tips/gotchas on this are welcome as well.

    Read the article

  • Clouds Everywhere But not a Drop of Rain – Part 3

    - by sxkumar
    I was sharing with you how a broad-based transformation such as cloud will increase agility and efficiency of an organization if process re-engineering is part of the plan.  I have also stressed on the key enterprise requirements such as “broad and deep solutions, “running your mission critical applications” and “automated and integrated set of capabilities”. Let me walk you through some key cloud attributes such as “elasticity” and “self-service” and what they mean for an enterprise class cloud. I will also talk about how we at Oracle have taken a very enterprise centric view to developing cloud solutions and how our products have been specifically engineered to address enterprise cloud needs. Cloud Elasticity and Enterprise Applications Requirements Easy and quick scalability for a short-period of time is the signature of cloud based solutions. It is this elasticity that allows you to dynamically redistribute your resources according to business priorities, helps increase your overall resource utilization, and reduces operational costs by allowing you to get the most out of your existing investment. Most public clouds are offering a instant provisioning mechanism of compute power (CPU, RAM, Disk), customer pay for the instance-hours(and bandwidth) they use, adding computing resources at peak times and removing them when they are no longer needed. This type of “just-in-time” serving of compute resources is well known for mid-tiers “state less” servers such as web application servers and web servers that just need another machine to start and run on it but what does it really mean for an enterprise application and its underlying data? Most enterprise applications are not as quite as “state less” and justifiably so. As such, how do you take advantage of cloud elasticity and make it relevant for your enterprise apps? This is where Cloud meets Grid Computing. At Oracle, we have invested enormous amount of time, energy and resources in creating enterprise grid solutions. All our technology products offer built-in elasticity via clustering and dynamic scaling. With products like Real Application Clusters (RAC), Automatic Storage Management, WebLogic Clustering, and Coherence In-Memory Grid, we allow all your enterprise applications to benefit from Cloud elasticity –both vertically and horizontally - without requiring any application changes. A number of technology vendors take a rather simplistic route of starting up additional or removing unneeded VM as the "Cloud Scale-Out" solution. While this may work for stateless mid-tier servers where load balancers can handle the addition and remove of instances transparently but following a similar approach for the database tier - often called as "database sharding" - requires significant application modification and typically does not work with off the shelf packaged applications. Technologies like Oracle Database Real Application Clusters, Automatic Storage Management, etc. on the other hand bring the benefits of incremental scalability and on-demand elasticity to ANY application by providing a simplified abstraction layers where the application does not need deal with data spread over multiple database instances. Rather they just talk to a single database and the database software takes care of aggregating resources across multiple hardware components. It is the technologies like these that truly make a cloud solution relevant for enterprises.  For customers who are looking for a next generation hardware consolidation platform, our engineered systems (e.g. Exadata, Exalogic) not only provide incredible amount of performance and capacity, they also reduce the data center complexity and simplify operations. Assemble, Deploy and Manage Enterprise Applications for Cloud Products like Oracle Virtual assembly builder (OVAB) resolve the complex problem of bringing the cloud speed to complex multi-tier applications. With assemblies, you can not only provision all components of a multi-tier application and wire them together by push of a button, other aspects of application lifecycle, such as real-time application testing, scale-up/scale-down, performance and availability monitoring, etc., are also automated using Oracle Enterprise Manager.  An essential criteria for an enterprise cloud to succeed is the ability to ensure business service levels especially when business users have either full visibility on the usage cost with a “show back” or a “charge back”. With Oracle Enterprise Manager 12c, we have created the most comprehensive cloud management solution in the industry that is capable of managing business service levels “applications-to-disk” in a enterprise private cloud – all from a single console. It is the only cloud management platform in the industry that allows you to deliver infrastructure, platform and application cloud services out of the box. Moreover, it offers integrated and complete lifecycle management of the cloud - including planning and set up, service delivery, operations management, metering and chargeback, etc .  Sounds unbelievable? Well, just watch this space for more details on how Oracle Enterprise Manager 12c is the nerve center of Oracle Cloud! Our cloud solution portfolio is also the broadest and most deep in the industry  - covering public, private, hybrid, Infrastructure, platform and applications clouds. It is no coincidence therefore that the Oracle Cloud today offers the most comprehensive set of public cloud services in the industry.  And to a large part, this has been made possible thanks to our years on investment in creating cloud enabling technologies.  Summary  But the intent of this blog post isn't to dwell on how great our solutions are (these are just some examples to illustrate how we at Oracle have approached this problem space). Rather it is to help you ask the right questions before you embark on your cloud journey.  So to summarize, here are the key takeaways.       It is critical that you are clear on why you are building the cloud. Successful organizations keep business benefits as the first and foremost cloud objective. On the other hand, those who approach this purely as a technology project are more likely to fail. Think about where you want to be in 3-5 years before you get started. Your long terms objectives should determine what your first step ought to be. As obvious as it may seem, more people than not make the first move without knowing where they are headed.  Don’t make the mistake of equating cloud to virtualization and Infrastructure-as-a-Service (IaaS). Spinning a VM on-demand will give some short term relief to your IT staff but is unlikely to solve your larger business problems. As such, even if IaaS is your first step towards a more comprehensive cloud, plan the roadmap around those higher level services before you begin. And ask your vendors on how they are going to be your partners in this journey. Capabilities like self-service access and chargeback/showback are absolutely critical if you really expect your cloud to be transformational. Your business won't see the full benefits of the cloud until it empowers them with same kind of control and transparency that they are used to while using a public cloud service.  Evaluate the benefits of integration, as opposed to blindly following the best-of-breed strategy. Integration is a huge challenge and more so in a cloud environment. There are enormous costs associated with stitching a solution out of disparate components and even more in maintaining it. Hope you found these ideas helpful. Looking forward to hearing your thoughts and experiences.

    Read the article

  • Pushing DNSSEC updates with offline keys

    - by eggyal
    In a non-professional capacity, I look after the DNS of some 18 domains: mostly personal/vanity domains for immediate family. I outsource the whole shebang to an inexpensive managed hosting provider with a web interface through which I manage the zones; since the provider also offers DNSSEC, I have successfully deployed that too. These domains are so unimportant that an attack targetted against them seems much less likely than a general compromise of my provider's systems, at which point the records of all their customers might be changed to misdirect traffic (perhaps with extremely long TTLs). DNSSEC could protect against such an attack, but only if the zone's private keys are not held by the hosting provider. So, I wonder: how can one keep DNSSEC private keys offline yet still transfer signed zones to an outsourced DNS host? The most obvious answer (to me, at least) is to run one's own shadow/hidden master (from which the provider can slave) and then copy offline-signed zonefiles to the master as required. The problem is that the only machine I (want to*) control is my personal laptop, which usually connects from a typical home ADSL (behind NAT over a dynamically-assigned IP address). Having them slave from that (e.g. with a very long Expiry time on the zone for periods when my laptop is offline/unavailable) would not only require a Dynamic DNS record from which they can slave (if indeed they can slave from a named host rather than a static IP address), but would also involve me running a DNS server on my laptop and opening both it and my home network up to the incoming zone transfer requests: not ideal. I would prefer a much more push-oriented design, whereby my laptop initiates transfer of offline-signed zonefiles/updates to the provider's servers. I looked into whether nsupdate could fit the bill: documentation is a little sketchy, but my testing (with BIND 9.7) suggests it can indeed update DNSSEC zones, but only where the server holds the keys to perform the zone signing; I have not found a way to have it take an update including the relevant RRSIG/NSEC/etc. records and have the server accept them. Is this a supported use-case? If not, I suspect the only solutions which could fit the bill will involve non-DNS-based transfer of the zone updates and would welcome recommendations that are supported by (hopefully inexpensive) hosting providers: SFTP/SCP? rsync? RDBMS replication? Proprietary API? Finally, what would be the practical implications of such a setup? Key rotation is jumping out at me as being an obvious difficulty, especially if my laptop is offline for extended periods. But the zones are extremely stable, so perhaps I could get away with long-lived ZSKs**...? * Whilst I could run a shadow/hidden master on e.g. an outsourced VPS, I dislike the overhead of having to secure / manage / monitor / maintain yet another system; not to mention the additional financial costs of so doing. ** Okay, this would enable a concerted attacker to replay outdated records—but the risk and impact of such are both tolerable in the case of these domains.

    Read the article

  • IPv6: Should I have private addresses?

    - by AlReece45
    Right now, we have a rack of servers. Every server right now has at least 2 IP addresses, one for the public interface, another for the private. The servers that have SSL websites on them have more IP addresses. We also have virtual servers, that are configured similarly. Private Network The private range is currently just used for backups and monitoring. Its a gigabit port, the interface usage does not usually get very high. There are other technologies we're considering using that would use this port: iSCSI (implementations usually recommends dedicating an interface to it, which would be yet another IP network), VPN to get access to the private range (something I'd rather avoid) dedicated database servers LDAP centralized configuration (like puppet) centralized logging We don't have any private addresses in our DNS records (only public addresses). For our servers to utilize the correct IP address for the right interface (and not hard code the IP address) probably requires setting up a private DNS server (So now we add 2 different dns entries to 2 different systems). Public Network Our public range has a variety of services include web, email, and ftp. There is a hardware firewall between our network and the "public" network. We have (relatively secure) method to instruct the firewall to open and close administrative access (web interfaces, ssh, etc) for our current IP address. With either solution discussed, the host-based firewalls will be configured as well. The public network currently runs at a dedicated 20Mbps link. There are a couple of legacy servers with fast-ethernet ports, but they are scheduled for decommissioning. All of the other production boxes have at least 2 Gigabit Ethernet ports. The more traffic-heavy servers have 4-6 available (none is using more than the 2 Gigabit ports right now). IPv6 I want to get an IPv6 prefix from our ISP. So at least every "server" has at least one IPv6 interface. We'll still need to keep the IPv4 addressees up and available for legacy clients (web servers and email at the very least). We have two IP networks right now. Adding the public IPv6 address would make it three. Just use IPv6? I'm thinking about just dumping the private IPv4 range and using the IPv6 range as the primary means of all communications. If an interface starts reaching its capacity, utilize the newly free interfaces to create a trunk. It has the advantage that if either the public or private traffic needs to exceed 1Gbps. The traffic for each interface is already analyzed on a regular basis to predict future bandwidth use. In the rare instances where bandwidth unexpected peaks: utilize QoS to ensure traffic (like our limited SSH access) is prioritized correctly so the problem can be corrected (if possible, our WAN is the bottleneck right now). It also has the advantage of not needing to make an entry for every private address. We may have private DNS (or just LDAP), but it'll be much more limited in scope with less entries to duplicate. Summary I'm trying to make this network as "simple" as possible. At the same time, I want to make sure its reliable, upgradeable, scalable, and (eventually) redundant. Having one IPv6 network, and a legacy IPv4 network seems to be the best solution to me. Regarding using assigned IPv6 addresses for both networks, sharing the available bandwidth on one (more trunked if needed): Are there any technical disadvantages (limitations, buffers, scalability)? Are there any other security considerations (asides from firewalls mentioned above) to consider? Are there regulations or other security requirements (like PCI-DSS) that this doesn't meet? Is there typical software for setting up a Linux network that doesn't have IPv6 support yet? (logging, ldap, puppet) Some other thing I didn't consider?

    Read the article

  • File server share access intermittent/slow/machine unstable: win2k8r2

    - by Jack B.
    I have a file server running Win2k8R2 on an older HP DL380G4. It has nothing set up on it other than file sharing. All drivers/firmware/updates installed. The file server is used as a dump for a bunch of test machines - so essentially a lot of small files are being written to it. It was working fine until it started showing the following symptoms: Shares became either very slow/intermittent or could not access them at all. Logging in the the server, you could use it like normal but windows would start freezing and eventually you had to hard reboot it because nothing was responsive. After rebooting, it would work fine for 20min-2hours and then degrade into this broken state again. Some info after investigation: HP Raid Config utility shows the Raid array as functioning properly (RAID5 btw). Event log shows a bunch of DoS attacks from the test machines, saying it has disconnected the connection a. AFAIK (not part of my job) the test machines haven't changed the way they log information to this server or the amount of them hasn't increased. b. Nothing is infected, this server was scanned fully, and the test machines are re-imaged almost daily. Nothing in performance monitor shows as anything being pegged at maximum (CPU/HD/Network/RAM) I installed MS Network Monitor and it is showing a lot of traffic The server was using one gigabit Ethernet connection, I connected the second one as well with the same results. Forgot to add - one of the commonly written to dirs on the share has over 16k subdirs in it, with a crapton of small files within those dirs. Some of the OS instability was slow access to the drive which has this directory - perfmon doesn't show much activity on the HD though so I'm not sure if this crowded dir is the cause. Here is one important fact: I ran into this issue 2-3 months ago, couldn't figure it out, but I had a spare identical machine so I swapped them out (thought it was related to the machine), and now I have the same issue. Also, the computer will be stable if I turn off file sharing. So is the server just getting DoS'd by the test machines? I've never dealt with such an issue. Is instability in the server's OS common when getting DoS'd? Is there anything I can do to confirm this before telling the owners of the test machines to optimize their traffic? (I'm not sure what they'll be able to do). Is there something within Win2k8R2 that can balance the traffic across the two NICs? Any help would be appreciated. Update: Another thought - the drive with the share is RAID5 across 6 SCSI320 300GB HDs. They are near full capacity about 100GB from 1TB left. Could the amount of tiny files could be causing some weirdness with the parity in this array? I think I've read something about this in the past but I'm no expert on RAID.

    Read the article

  • mySQL Optimization Suggestions

    - by Brian Schroeter
    I'm trying to optimize our mySQL configuration for our large Magento website. The reason I believe that mySQL needs to be configured further is because New Relic has shown that our SELECT queries are taking a long time (20,000+ ms) in some categories. I ran MySQLTuner 1.3.0 and got the following results... (Disclaimer: I restarted mySQL earlier after tweaking some settings, and so the results here may not be 100% accurate): >> MySQLTuner 1.3.0 - Major Hayden <[email protected]> >> Bug reports, feature requests, and downloads at http://mysqltuner.com/ >> Run with '--help' for additional options and output filtering [OK] Currently running supported MySQL version 5.5.37-35.0 [OK] Operating on 64-bit architecture -------- Storage Engine Statistics ------------------------------------------- [--] Status: +ARCHIVE +BLACKHOLE +CSV -FEDERATED +InnoDB +MRG_MYISAM [--] Data in MyISAM tables: 7G (Tables: 332) [--] Data in InnoDB tables: 213G (Tables: 8714) [--] Data in PERFORMANCE_SCHEMA tables: 0B (Tables: 17) [--] Data in MEMORY tables: 0B (Tables: 353) [!!] Total fragmented tables: 5492 -------- Security Recommendations ------------------------------------------- [!!] User '@host5.server1.autopartsnetwork.com' has no password set. [!!] User '@localhost' has no password set. [!!] User 'root@%' has no password set. -------- Performance Metrics ------------------------------------------------- [--] Up for: 5h 3m 4s (5M q [317.443 qps], 42K conn, TX: 18B, RX: 2B) [--] Reads / Writes: 95% / 5% [--] Total buffers: 35.5G global + 184.5M per thread (1024 max threads) [!!] Maximum possible memory usage: 220.0G (174% of installed RAM) [OK] Slow queries: 0% (6K/5M) [OK] Highest usage of available connections: 5% (61/1024) [OK] Key buffer size / total MyISAM indexes: 512.0M/3.1G [OK] Key buffer hit rate: 100.0% (102M cached / 45K reads) [OK] Query cache efficiency: 66.9% (3M cached / 5M selects) [!!] Query cache prunes per day: 3486361 [OK] Sorts requiring temporary tables: 0% (0 temp sorts / 812K sorts) [!!] Joins performed without indexes: 1328 [OK] Temporary tables created on disk: 11% (126K on disk / 1M total) [OK] Thread cache hit rate: 99% (61 created / 42K connections) [!!] Table cache hit rate: 19% (9K open / 49K opened) [OK] Open file limit used: 2% (712/25K) [OK] Table locks acquired immediately: 100% (5M immediate / 5M locks) [!!] InnoDB buffer pool / data size: 32.0G/213.4G [OK] InnoDB log waits: 0 -------- Recommendations ----------------------------------------------------- General recommendations: Run OPTIMIZE TABLE to defragment tables for better performance MySQL started within last 24 hours - recommendations may be inaccurate Reduce your overall MySQL memory footprint for system stability Enable the slow query log to troubleshoot bad queries Increasing the query_cache size over 128M may reduce performance Adjust your join queries to always utilize indexes Increase table_cache gradually to avoid file descriptor limits Read this before increasing table_cache over 64: http://bit.ly/1mi7c4C Variables to adjust: *** MySQL's maximum memory usage is dangerously high *** *** Add RAM before increasing MySQL buffer variables *** query_cache_size (> 512M) [see warning above] join_buffer_size (> 128.0M, or always use indexes with joins) table_cache (> 12288) innodb_buffer_pool_size (>= 213G) My my.cnf configuration is as follows... [client] port = 3306 [mysqld_safe] nice = 0 [mysqld] tmpdir = /var/lib/mysql/tmp user = mysql port = 3306 skip-external-locking character-set-server = utf8 collation-server = utf8_general_ci event_scheduler = 0 key_buffer = 512M max_allowed_packet = 64M thread_stack = 512K thread_cache_size = 512 sort_buffer_size = 24M read_buffer_size = 8M read_rnd_buffer_size = 24M join_buffer_size = 128M # for some nightly processes client sessions set the join buffer to 8 GB auto-increment-increment = 1 auto-increment-offset = 1 myisam-recover = BACKUP max_connections = 1024 # max connect errors artificially high to support behaviors of NetScaler monitors max_connect_errors = 999999 concurrent_insert = 2 connect_timeout = 5 wait_timeout = 180 net_read_timeout = 120 net_write_timeout = 120 back_log = 128 # this table_open_cache might be too low because of MySQL bugs #16244691 and #65384) table_open_cache = 12288 tmp_table_size = 512M max_heap_table_size = 512M bulk_insert_buffer_size = 512M open-files-limit = 8192 open-files = 1024 query_cache_type = 1 # large query limit supports SOAP and REST API integrations query_cache_limit = 4M # larger than 512 MB query cache size is problematic; this is typically ~60% full query_cache_size = 512M # set to true on read slaves read_only = false slow_query_log_file = /var/log/mysql/slow.log slow_query_log = 0 long_query_time = 0.2 expire_logs_days = 10 max_binlog_size = 1024M binlog_cache_size = 32K sync_binlog = 0 # SSD RAID10 technically has a write capacity of 10000 IOPS innodb_io_capacity = 400 innodb_file_per_table innodb_table_locks = true innodb_lock_wait_timeout = 30 # These servers have 80 CPU threads; match 1:1 innodb_thread_concurrency = 48 innodb_commit_concurrency = 2 innodb_support_xa = true innodb_buffer_pool_size = 32G innodb_file_per_table innodb_flush_log_at_trx_commit = 1 innodb_log_buffer_size = 2G skip-federated [mysqldump] quick quote-names single-transaction max_allowed_packet = 64M I have a monster of a server here to power our site because our catalog is very large (300,000 simple SKUs), and I'm just wondering if I'm missing anything that I can configure further. :-) Thanks!

    Read the article

  • File server share access intermittent/slow/machine unstable: win2kr2

    - by Jack B.
    I have a file server running Win2k8R2 on an older HP DL380G4. It has nothing set up on it other than file sharing. All drivers/firmware/updates installed. The file server is used as a dump for a bunch of test machines - so essentially a lot of small files are being written to it. It was working fine until it started showing the following symptoms: Shares became either very slow/intermittent or could not access them at all. Logging in the the server, you could use it like normal but windows would start freezing and eventually you had to hard reboot it because nothing was responsive. After rebooting, it would work fine for 20min-2hours and then degrade into this broken state again. Some info after investigation: HP Raid Config utility shows the Raid array as functioning properly (RAID5 btw). Event log shows a bunch of DoS attacks from the test machines, saying it has disconnected the connection a. AFAIK (not part of my job) the test machines haven't changed the way they log information to this server or the amount of them hasn't increased. b. Nothing is infected, this server was scanned fully, and the test machines are re-imaged almost daily. Nothing in performance monitor shows as anything being pegged at maximum (CPU/HD/Network/RAM) I installed MS Network Monitor and it is showing a lot of traffic The server was using one gigabit Ethernet connection, I connected the second one as well with the same results. Forgot to add - one of the commonly written to dirs on the share has over 16k subdirs in it, with a crapton of small files within those dirs. Some of the OS instability was slow access to the drive which has this directory - perfmon doesn't show much activity on the HD though so I'm not sure if this crowded dir is the cause. Here is one important fact: I ran into this issue 2-3 months ago, couldn't figure it out, but I had a spare identical machine so I swapped them out (thought it was related to the machine), and now I have the same issue. Also, the computer will be stable if I turn off file sharing. So is the server just getting DoS'd by the test machines? I've never dealt with such an issue. Is instability in the server's OS common when getting DoS'd? Is there anything I can do to confirm this before telling the owners of the test machines to optimize their traffic? (I'm not sure what they'll be able to do). Is there something within Win2k8R2 that can balance the traffic across the two NICs? Any help would be appreciated. Update: Another thought - the drive with the share is RAID5 across 6 SCSI320 300GB HDs. They are near full capacity about 100GB from 1TB left. Could the amount of tiny files could be causing some weirdness with the parity in this array? I think I've read something about this in the past but I'm no expert on RAID.

    Read the article

  • DRBD Not syncing between my nodes

    - by Mike Curry
    Some version info: Operating system is Ubuntu 11.10, on EC2, kernel is 3.0.0-16-virtual and the application info is: Version: 8.3.11 (api:88) GIT-hash: 0de839cee13a4160eed6037c4bddd066645e23c5 build by buildd@allspice, 2011-07-05 19:51:07 Getting some strange errors in dmesg (seen below) as well, there is no replication happening. I have made my first node primary and its showing: drbd driver loaded OK; device status: version: 8.3.11 (api:88/proto:86-96) srcversion: DA5A13F16DE6553FC7CE9B2 m:res cs ro ds p mounted fstype 0:r0 StandAlone Primary/Unknown UpToDate/DUnknown r----s ext3 my secondary node is showing: drbd driver loaded OK; device status: version: 8.3.11 (api:88/proto:86-96) srcversion: DA5A13F16DE6553FC7CE9B2 m:res cs ro ds p mounted fstype 0:r0 StandAlone Secondary/Unknown Inconsistent/DUnknown r----s Showing /proc/drbd on the master shows: version: 8.3.11 (api:88/proto:86-96) srcversion: DA5A13F16DE6553FC7CE9B2 0: cs:StandAlone ro:Primary/Unknown ds:UpToDate/DUnknown r----s ns:0 nr:0 dw:4 dr:1073 al:0 bm:0 lo:0 pe:0 ua:0 ap:0 ep:1 wo:f oos:262135964 Showing /proc/drbd on the slave shows that there is nothing being transfered... version: 8.3.11 (api:88/proto:86-96) srcversion: DA5A13F16DE6553FC7CE9B2 0: cs:StandAlone ro:Secondary/Unknown ds:Inconsistent/DUnknown r----s ns:0 nr:0 dw:0 dr:0 al:0 bm:0 lo:0 pe:0 ua:0 ap:0 ep:1 wo:f oos:262135964 Here is my config... resource r0 { protocol C; startup { wfc-timeout 15; degr-wfc-timeout 60; } net { cram-hmac-alg sha1; shared-secret "test123; } on drbd01 { device /dev/drbd0; disk /dev/xvdm; address 23.XX.XX.XX:7788; # blocked out ip meta-disk internal; } on drbd02 { device /dev/drbd0; disk /dev/xvdm; address 184.XX.XX.XX:7788; #blocked out ip meta-disk internal; } } I have run the following on the master: sudo drbdadm -- --overwrite-data-of-peer primary all There is no firewall between the systems. Here is the dmesg with some errors: [2285172.969955] drbd: initialized. Version: 8.3.11 (api:88/proto:86-96) [2285172.969960] drbd: srcversion: DA5A13F16DE6553FC7CE9B2 [2285172.969962] drbd: registered as block device major 147 [2285172.969965] drbd: minor_table @ 0xffff88000276ea00 [2285173.000952] block drbd0: Starting worker thread (from drbdsetup [1300]) [2285173.003971] block drbd0: disk( Diskless -> Attaching ) [2285173.006150] block drbd0: No usable activity log found. [2285173.006154] block drbd0: Method to ensure write ordering: flush [2285173.006158] block drbd0: max BIO size = 4096 [2285173.006165] block drbd0: drbd_bm_resize called with capacity == 524271928 [2285173.008512] block drbd0: resync bitmap: bits=65533991 words=1023969 pages=2000 [2285173.008518] block drbd0: size = 250 GB (262135964 KB) [2285173.079566] block drbd0: bitmap READ of 2000 pages took 17 jiffies [2285173.081189] block drbd0: recounting of set bits took additional 1 jiffies [2285173.081194] block drbd0: 250 GB (65533991 bits) marked out-of-sync by on disk bit-map. [2285173.081203] block drbd0: Suspended AL updates [2285173.081210] block drbd0: disk( Attaching -> UpToDate ) [2285173.081214] block drbd0: attached to UUIDs 1C1291D39584C1D1:0000000000000004:0000000000000000:0000000000000000 [2285173.095016] block drbd0: conn( StandAlone -> Unconnected ) [2285173.095046] block drbd0: Starting receiver thread (from drbd0_worker [1301]) [2285173.099297] block drbd0: receiver (re)started [2285173.099304] block drbd0: conn( Unconnected -> WFConnection ) [2285173.099330] block drbd0: bind before connect failed, err = -99 [2285173.099346] block drbd0: conn( WFConnection -> Disconnecting ) [2285173.295788] block drbd0: Discarding network configuration. [2285173.295815] block drbd0: Connection closed [2285173.295826] block drbd0: conn( Disconnecting -> StandAlone ) [2285173.295840] block drbd0: receiver terminated [2285173.295844] block drbd0: Terminating drbd0_receiver Edit: Reading some other similar issues, it was suggested to do a 'drbdadm dump all', so I figured it couldn't hurt. ubuntu@drbd01:~$ drbdadm dump all /etc/drbd.conf:19: in resource r0, on drbd01: IP 23.XX.XX.XX not found on this host. and on slave: root@drbd02:~# drbdadm dump all /etc/drbd.conf:25: in resource r0, on drbd02: IP 184.XX.XX.XX not found on this host. Strange it doesn't find its own ip, however, this is an Amazon EC2 system using an elastic IP... here are my ipconfigs for both... master: ubuntu@drbd01:~$ ifconfig eth0 Link encap:Ethernet HWaddr 22:00:0a:1c:27:11 inet addr:10.28.39.17 Bcast:10.28.39.63 Mask:255.255.255.192 inet6 addr: fe80::2000:aff:fe1c:2711/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:1569 errors:0 dropped:0 overruns:0 frame:0 TX packets:1169 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:124409 (124.4 KB) TX bytes:213601 (213.6 KB) Interrupt:26 lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:0 (0.0 B) TX bytes:0 (0.0 B) slave: root@drbd02:~# ifconfig eth0 Link encap:Ethernet HWaddr 12:31:3f:00:14:9d inet addr:10.160.27.107 Bcast:10.160.27.255 Mask:255.255.254.0 inet6 addr: fe80::1031:3fff:fe00:149d/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:915 errors:0 dropped:0 overruns:0 frame:0 TX packets:774 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:75381 (75.3 KB) TX bytes:109673 (109.6 KB) Interrupt:26 lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:0 (0.0 B) TX bytes:0 (0.0 B)

    Read the article

  • PHP+Apache as forward/reverse proxy: ¿how to process client requests and server responses in PHP?

    - by Lightworker
    Hi! I'm having a lot of troubles with the propper configuration of Apache mod_proxy.so to work as desired... The main idea, is to create a proxy on a local machine in a network wich will have the ability to proces a client request (client connected through this Apache prepared proxy) in PHP. And also, it will have the capacity to process the server responses on PHP too. Those are the 2 funcionalities, and they are independent one from each other. Let me present a little schema of what I need to achive: As you can see here, there're 2 ways: blue one and red one. For the blue one, I basically conected a client (Machine B - cell phone) on my local network (home) and configured it to go thorugh a proxy, wich is the Machine A (personal computer) on the exactly same network. So let's say (not DHCP): Machine A: 192.168.1.40 -- Apache is running on this machine, and configured to listen port 80. Machine B (cell phone): 192.168.1.75 -- configured to go throug a proxy, wich is IP 192.168.1.75 and port 80 (basically, Machine A). After configuring Apache properly, wich is basically to remove the "#" from httpd.conf on the lines for the mod_proxy.so (main worker), mod_proxy_connect.so (SSL, allowCONNECT, ...) and mod_proxy_http.so (needed for handle HTTP request/responses) and having in my case, lines like this: # Implements a proxy/gateway for Apache. Include "conf/extra/httpd-proxy.conf" # Various default settings Include "conf/extra/httpd-default.conf" # Secure (SSL/TLS) connections Include "conf/extra/httpd-ssl.conf" wich gives me the ability to configure the file httpd-proxy.conf to prepare the forward proxy or the reverse proxy. So I'm not sure, if what I need it's a forward proxy or a reverse one. For a forward proxy I've done this: <IfModule proxy_module> <IfModule proxy_http_module> # # FORWARD Proxy # #ProxyRequests Off ProxyRequests On ProxyVia On <Proxy *> Order deny,allow # Allow from all Deny from all Allow from 192.168.1 </Proxy> </IfModule> </IfModule> wich basically passes all the packets normally to the server and back to the client. I can trace it perfectly (and testing that works) looking at the "access.log" from Apache. Any request I make with the cell phone, appears then on the Apache log. So it works. But here come the problem: I need to process those client requests. And I need to do it, in PHP. I have read a lot about this. I've read in detail the oficial site from Apache about mod_proxy. And I've searched a lot on forums, but without luck. So I thought about a first aproximation: 1) Forward proxy in Apache, passes all the packets and it's not possible to process them. This seems to be true, so, what about a reverse proxy? So I envisioned something like: ProxyRequests Off <Proxy *> Order deny,allow Allow from all </Proxy> ProxyPass http://www.google.com http://www.yahoo.com ProxyPassReverse http://www.google.com http://www.yahoo.com which is just a test, but this should cause on my cell phone that when trying to navigate to Google, I should be going to Yahoo, isn't it? But not. It doesn't work. So you really see, that ALL the examples on Apache reverse proxy, goes like: ProxyPass /foo http://foo.example.com/bar ProxyPassReverse /foo http://foo.example.com/bar wich means, that any kind of request in a local context, will be solved on a remote location. But what I needed is the inverse! It's that when asking for a remote site on my phone, I solve this request on my local server (the Apache one) to process it with a PHP module. So, if it's a forward proxy, I need to pass through PHP first. If it's a reverse proxy, I need to change the "going" direction to my local server one to process first on PHP. Then comes in mind second option: 2) I've seen something like: <Proxy http://example.com/foo/*> SetOutputFilter INCLUDES </Proxy> And I started to search for SetOutputFilter, SetInputFilter, AddOutputFilter and AddInputFilter. But I don't really know how can I use it. Seems to be good, or a solution to me, cause with somethin' like this, I should can add an Input filter to process on PHP the client requests and send back to the client what I programed/want (not the remote server response) wich is the BLUE path on schema, and I should have the ability to add an Output filter wich seems to give me the ability to process the remote server response befor sending it to the client, wich should be the RED path on the schema. Red path, it's just to read server responses and play with em. But nothing more. The Blue path, it's the important one. Cause I will send to the client whatever I want after procesing the requests. I so sorry for this amazingly big post, but I needed to explain it as well as I can. I hope someone will understand my problem, and will help me to solve it! Lot of thanks in advance!! :)

    Read the article

  • Confirm disk is broken when it passes all diagnostics

    - by Halfgaar
    I have a system with a potentially broken disk, but the disk passes all manner of diagnostics. I have been unable to confirm that the disk is broken. What are my options? I could just replace the disk, but because this situation is very similar to another more severe situation I have (long story), I'd like to actually make a proper diagnosis as opposed to randomly binning hardware. The issue and history is this: I had a Debian Linux PC (500 MHz P3) acting as router, nagios and munin. It crashed every couple of weeks. No logs or dmesg could be obtained (because it's an old Compaq that only boots when you configure it as keyboardless, making connecting a keyboard later, once it's booted, impossible). At the time, I just replaced the computer with another Compaq (P4 2.4 GHz) because I thought the hardware was faulty. However, it still crashed every couple of weeks. the difference is that on this computer, I can still SSH into it. It gives all kinds of errors on hda. I'd like to confirm that the disk is broken, but nothing I do confirms this: SMART error logs shows no errors. Normally when a disk starts acting up, SMART my pass, but it still records a read-error in the error log. SMART self-test (smartctl -t long /dev/sda) completes without errors. re-allocated sector count (a tell-tale parameter) has been 31 all its life, even when the disk was still in use in my desktop PC years ago, and it still is. The figure never changed. dd if=/dev/sda of=/dev/null bs=4096 passes with flying colors. What else can I do to assess the health of the drive? Again, this is not about making this router fully functional again, this is a disk forensic question, because it just so happens that I have another server that potentially has the same problem, and knowing the answer to this will possibly help me greatly. For the record, below are logs and such. This is the smartctl -a output: smartctl 5.40 2010-07-12 r3124 [i686-pc-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Model Family: Seagate Barracuda 7200.7 and 7200.7 Plus family Device Model: ST3120026A Serial Number: 5JT1CLQM Firmware Version: 3.06 User Capacity: 120,034,123,776 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 6 ATA Standard is: ATA/ATAPI-6 T13 1410D revision 2 Local Time is: Mon Jul 1 21:18:33 2013 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 24) The self-test routine was aborted by the host. Total time to complete Offline data collection: ( 430) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. No General Purpose Logging support. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 85) minutes. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 050 046 006 Pre-fail Always - 47766662 3 Spin_Up_Time 0x0003 097 096 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 10 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 31 7 Seek_Error_Rate 0x000f 084 060 030 Pre-fail Always - 820305 9 Power_On_Hours 0x0032 048 048 000 Old_age Always - 46373 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 605 194 Temperature_Celsius 0x0022 036 065 000 Old_age Always - 36 195 Hardware_ECC_Recovered 0x001a 050 046 000 Old_age Always - 47766662 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 196 000 Old_age Always - 6 200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline - 0 202 Data_Address_Mark_Errs 0x0032 100 253 000 Old_age Always - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Aborted by host 80% 46361 - # 2 Extended offline Completed without error 00% 46358 - # 3 Short offline Completed without error 00% 12046 - # 4 Extended offline Completed without error 00% 10472 - # 5 Short offline Completed without error 00% 10471 - # 6 Short offline Completed without error 00% 10471 - # 7 Short offline Completed without error 00% 6770 - # 8 Extended offline Aborted by host 90% 5958 - # 9 Extended offline Aborted by host 90% 5951 - #10 Short offline Completed without error 00% 5024 - #11 Extended offline Aborted by host 80% 5024 - #12 Short offline Completed without error 00% 3697 - #13 Short offline Completed without error 00% 237 - #14 Short offline Completed without error 00% 145 - #15 Short offline Completed without error 00% 69 - #16 Extended offline Completed without error 00% 68 - #17 Short offline Completed without error 00% 66 - #18 Short offline Completed without error 00% 49 - #19 Short offline Completed without error 00% 29 - #20 Short offline Completed without error 00% 29 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. And this is the dmesg error when it has crashed (which repeats for a bunch of different sectors): [1755091.211136] sd 0:0:0:0: [sda] Unhandled error code [1755091.211144] sd 0:0:0:0: [sda] Result: hostbyte=DID_BAD_TARGET driverbyte=DRIVER_OK [1755091.211151] sd 0:0:0:0: [sda] CDB: Read(10): 28 00 08 fe ad 38 00 00 08 00 [1755091.211166] end_request: I/O error, dev sda, sector 150908216

    Read the article

  • Skipping scheduled self-tests and predicting drive EOL

    - by Steve Madsen
    For a few weeks now, smartd has been reporting that it is skipping some of its scheduled self-tests on the weekends: Apr 24 18:29:32 calvin smartd[4758]: Device: /dev/sda, skip scheduled Offline Immediate Test; 40% remaining of current Self-Test. Apr 24 18:29:33 calvin smartd[4758]: Device: /dev/sdb, skip scheduled Offline Immediate Test; 50% remaining of current Self-Test. The drives in this RAID-1 array are set to run an offline test four times a day, a short self-test at 2am every day, and a long self-test on Saturdays at 2am. For some reason, it looks like the long self-test is taking longer, causing the other scheduled tests to be skipped. First question: is this a sign of likely drive failure? Then today, smartd reported that a self-test failed. Here is the output of smartctl -a /dev/sdb: smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Model Family: Seagate Barracuda 7200.8 family Device Model: ST3250823AS Serial Number: 3ND1GNBC Firmware Version: 3.03 User Capacity: 250,059,350,016 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 7 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Sun Apr 25 13:15:34 2010 EDT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 430) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 84) minutes. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 047 039 006 Pre-fail Always - 168450357 3 Spin_Up_Time 0x0003 098 098 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 33 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 9 7 Seek_Error_Rate 0x000f 087 060 030 Pre-fail Always - 654745480 9 Power_On_Hours 0x0032 055 055 000 Old_age Always - 40141 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 51 194 Temperature_Celsius 0x0022 037 062 000 Old_age Always - 37 (0 17 0 0) 195 Hardware_ECC_Recovered 0x001a 047 039 000 Old_age Always - 168450357 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline - 0 202 TA_Increase_Count 0x0032 100 253 000 Old_age Always - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 40131 - # 2 Extended offline Completed: read failure 30% 40129 379795511 # 3 Short offline Completed without error 00% 40084 - # 4 Short offline Completed without error 00% 40060 - # 5 Short offline Completed without error 00% 40036 - # 6 Short offline Completed without error 00% 40013 - # 7 Short offline Completed without error 00% 39990 - # 8 Extended offline Completed without error 00% 39977 - # 9 Short offline Completed without error 00% 39919 - #10 Short offline Completed without error 00% 39895 - #11 Short offline Completed without error 00% 39872 - #12 Short offline Completed without error 00% 39848 - #13 Short offline Completed without error 00% 39824 - #14 Short offline Completed without error 00% 39801 - #15 Extended offline Completed without error 00% 39789 - #16 Short offline Completed without error 00% 39754 - #17 Short offline Completed without error 00% 39732 - #18 Short offline Completed without error 00% 39707 - #19 Short offline Completed without error 00% 39683 - #20 Short offline Completed without error 00% 39660 - #21 Short offline Completed without error 00% 39636 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. Given that this drive is about 4.5 years old, I am probably tempting fate by keeping it in service. SMART doesn't seem to get much respect as a reliable way to predict drive failure. What else can I use to get an early indication of drive failure?

    Read the article

  • Unicast traffic between hosts on a switch leaving the switch by its uplink. Why?

    - by Rich Lafferty
    I have a weird thing happening on our network at my office which I can't quite get my head around. In particular I can't tell if it's a problem with a switch, or a problem with configuration. We have a Cisco SG300-52 switch (sw01) in the top of a rack in our server room, connected to another SG300-28 that acts as our core switch (core01). Both run layer 2 only, our firewalls do routing between VLANs. They have a dozen or so VLANs between them. Gi1 on sw01 is a trunk port connected to gi1 on core01. (Disclosure: There are other switches in our environment but I'm pretty sure I've isolated the problem down to these two. Happy to provide more info if necessary.) The behaviour I'm seeing is limited to one VLAN, vlan 12 -- or, at least, it's not happening on the other ones I checked (It's hard to guarantee the absence of packets), and it is: sw01 is forwarding, to core01, traffic which is between two hosts which are both plugged into sw01. (I noticed this because the IDS in our firewall gave a false positive on traffic which should not reach the firewall.) We noticed this mostly between our two dhcp/dns servers, net01 (10.12.0.10) and net02 (10.12.0.11). net01 is physical hardware and net02 is on a VMware ESX server. net01 is connected to gi44 on sw01 and net02's ESX server to gi11. [net01]----gi44-[sw01]-gi1----gi1-[core01] [net02]----gi11/ Let's see some interfaces! Remember, vlan 12 is the problem vlan. Of the others I explicitly verified that vlan 27 was not affected. Here's the two hosts' ports: esx01 contains net02. sw01#sh run int gi11 interface gigabitethernet11 description esx01 lldp med disable switchport trunk allowed vlan add 5-7,11-13,100 switchport trunk native vlan 27 ! sw01#sh run int gi44 interface gigabitethernet44 description net01-1 lldp med disable switchport mode access switchport access vlan 12 ! Here's the trunk on sw01. sw01#sh run int gi1 interface gigabitethernet1 description "trunk to core01" lldp med disable switchport trunk allowed vlan add 4-7,11-13,27,100 ! And the other end of the trunk on core01. interface gigabitethernet1 description sw01 macro description switch switchport trunk allowed vlan add 2-7,11-16,27,100 ! I have a monitor port on core01, thus: core01#sh run int gi12 interface gigabitethernet12 description "monitor port" port monitor GigabitEthernet 1 ! And the monitor port on core01 sees unicast traffic going between net01 and net02, both of which are on sw01! I've verified this with a monitor port on sw01 that sees the net01-net02 unicast traffic leaving via gi1 too. sw01 knows that both of those hosts are on ports that are not its trunk port: :) ratchet$ arp -a | grep net net02.2ndsiteinc.com (10.12.0.11) at 00:0C:29:1A:66:15 [ether] on eth0 net01.2ndsiteinc.com (10.12.0.10) at 00:11:43:D8:9F:94 [ether] on eth0 sw01#sh mac addr addr 00:0C:29:1A:66:15 Aging time is 300 sec Vlan Mac Address Port Type -------- --------------------- ---------- ---------- 12 00:0c:29:1a:66:15 gi11 dynamic sw01#sh mac addr addr 00:11:43:D8:9F:94 Aging time is 300 sec Vlan Mac Address Port Type -------- --------------------- ---------- ---------- 12 00:11:43:d8:9f:94 gi44 dynamic I also brought up an unused port on sw01 on vlan 12, but the unicast traffic was (as best as I could tell) not coming out that port. So it doesn't look like sw01 is pushing it out all its ports, just the right ports and also gi1! I've verified that sw01 is not filling up its address-table: sw01#sh mac addr count This may take some time. Capacity : 8192 Free : 7983 Used : 208 The full configs for both core01 and sw01 are available: core01, sw01. Finally, versions: sw01#sh ver SW version 1.1.2.0 ( date 12-Nov-2011 time 23:34:26 ) Boot version 1.0.0.4 ( date 08-Apr-2010 time 16:37:57 ) HW version V01 core01#sh ver SW version 1.1.2.0 ( date 12-Nov-2011 time 23:34:26 ) Boot version 1.1.0.6 ( date 11-May-2011 time 18:31:00 ) HW version V01 So my understanding is this: sw01 should take unicast traffic for net01 and send it only out net02's port, and vice versa; none of it should go out sw01's uplink. But core01, receiving traffic on gi1 for a host it knows is on gi1, is right in sending it out all of its ports. (That is: sw01 is misbehaving, but core01 is doing what it should given the circumstances.) My question is: Why is sw01 sending that unicast traffic out its uplink, gi1? (And pre-emptively: yes, I know SG300s leave much to be desired, and yes, we should have spanning-tree enabled, but that's where I'm at right now.)

    Read the article

  • Ubuntu, No wireless networks found after correctly installed madwifi

    - by Peter
    Hi, I just installed madwifi on my MSI laptop with an Atheros AR5001 wifi card & Lucid. As far as I can see and according to System - Administration - Hardware drivers the install was successful and the card + driver is up and running. However, I don't see any wireless network (my windows PC can see about 5 wireless networks). I tried it with the network manager applet as well as with wicd. If I try to connect to "Hidden Wireless Network" via nm-applet, it will start to connect for a while but is unable too (although I supply it with the correct WEP settings & key) So, I'm unable to use my wireless network. What am i doing wrong? Some information about my system: iwconfig lo no wireless extensions. eth0 no wireless extensions. wifi0 no wireless extensions. ath0 IEEE 802.11g ESSID:"" Mode:Managed Frequency:2.437 GHz Access Point: Not-Associated Bit Rate:0 kb/s Tx-Power:17 dBm Sensitivity=1/1 Retry:off RTS thr:off Fragment thr:off Power Management:off Link Quality=0/70 Signal level=-96 dBm Noise level=-96 dBm Rx invalid nwid:0 Rx invalid crypt:0 Rx invalid frag:0 Tx excessive retries:0 Invalid misc:0 Missed beacon:0 pan0 no wireless extensions. ifconfig ath0 Link encap:Ethernet HWaddr 00:15:af:cf:e2:ca inet6 addr: fe80::215:afff:fecf:e2ca/64 Scope:Link UP BROADCAST MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:0 (0.0 B) TX bytes:0 (0.0 B) eth0 Link encap:Ethernet HWaddr 00:21:85:4d:82:78 inet addr:192.168.2.101 Bcast:192.168.2.255 Mask:255.255.255.0 inet6 addr: fe80::221:85ff:fe4d:8278/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:3800 errors:0 dropped:0 overruns:0 frame:0 TX packets:2944 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:3940261 (3.9 MB) TX bytes:525218 (525.2 KB) Interrupt:27 lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:12 errors:0 dropped:0 overruns:0 frame:0 TX packets:12 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:720 (720.0 B) TX bytes:720 (720.0 B) wifi0 Link encap:UNSPEC HWaddr 00-15-AF-CF-E2-CA-00-00-00-00-00-00-00-00-00-00 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:3497 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:280 RX bytes:0 (0.0 B) TX bytes:179947 (179.9 KB) Interrupt:16 lshw -C network *-network description: Wireless interface product: AR5001 Wireless Network Adapter vendor: Atheros Communications Inc. physical id: 0 bus info: pci@0000:02:00.0 logical name: wifi0 version: 01 serial: 00:15:af:cf:e2:ca width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix bus_master cap_list logical ethernet physical wireless configuration: broadcast=yes driver=ath_pci latency=0 multicast=yes wireless=IEEE 802.11g resources: irq:16 memory:fd7f0000-fd7fffff *-network description: Ethernet interface product: RTL8111/8168B PCI Express Gigabit Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:05:00.0 logical name: eth0 version: 01 serial: 00:21:85:4d:82:78 size: 100MB/s capacity: 1GB/s width: 64 bits clock: 33MHz capabilities: pm vpd msi pciexpress bus_master cap_list rom ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8169 driverversion=2.3LK-NAPI duplex=full ip=192.168.2.101 latency=0 link=yes multicast=yes port=MII speed=100MB/s resources: irq:27 ioport:c800(size=256) memory:fe2ff000-fe2fffff memory:fe2c0000-fe2dffff(prefetchable) lspci 00:00.0 Host bridge: ATI Technologies Inc RS690 Host Bridge 00:01.0 PCI bridge: ATI Technologies Inc RS690 PCI to PCI Bridge (Internal gfx) 00:04.0 PCI bridge: ATI Technologies Inc Device 7914 00:06.0 PCI bridge: ATI Technologies Inc RS690 PCI to PCI Bridge (PCI Express Port 2) 00:07.0 PCI bridge: ATI Technologies Inc RS690 PCI to PCI Bridge (PCI Express Port 3) 00:12.0 SATA controller: ATI Technologies Inc SB600 Non-Raid-5 SATA 00:13.0 USB Controller: ATI Technologies Inc SB600 USB (OHCI0) 00:13.1 USB Controller: ATI Technologies Inc SB600 USB (OHCI1) 00:13.2 USB Controller: ATI Technologies Inc SB600 USB (OHCI2) 00:13.3 USB Controller: ATI Technologies Inc SB600 USB (OHCI3) 00:13.4 USB Controller: ATI Technologies Inc SB600 USB (OHCI4) 00:13.5 USB Controller: ATI Technologies Inc SB600 USB Controller (EHCI) 00:14.0 SMBus: ATI Technologies Inc SBx00 SMBus Controller (rev 14) 00:14.1 IDE interface: ATI Technologies Inc SB600 IDE 00:14.2 Audio device: ATI Technologies Inc SBx00 Azalia (Intel HDA) 00:14.3 ISA bridge: ATI Technologies Inc SB600 PCI to LPC Bridge 00:14.4 PCI bridge: ATI Technologies Inc SBx00 PCI to PCI Bridge 00:18.0 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] HyperTransport Technology Configuration 00:18.1 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] Address Map 00:18.2 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] DRAM Controller 00:18.3 Host bridge: Advanced Micro Devices [AMD] K8 [Athlon64/Opteron] Miscellaneous Control 01:05.0 VGA compatible controller: ATI Technologies Inc RS690M [Radeon X1200 Series] 01:05.2 Audio device: ATI Technologies Inc Radeon X1200 Series Audio Controller 02:00.0 Ethernet controller: Atheros Communications Inc. AR5001 Wireless Network Adapter (rev 01) 05:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller (rev 01) 06:04.0 CardBus bridge: O2 Micro, Inc. OZ711MP1/MS1 MemoryCardBus Controller (rev 21) 06:04.2 SD Host controller: O2 Micro, Inc. Integrated MMC/SD Controller (rev 01) 06:04.3 Bridge: O2 Micro, Inc. Integrated MS/xD Controller (rev 01) 06:04.4 FireWire (IEEE 1394): O2 Micro, Inc. Firewire (IEEE 1394) (rev 02) less /proc/modules | grep ath ath_rate_sample 11476 1 - Live 0xf812b000 ath_pci 193197 0 - Live 0xf85c3000 wlan 222892 5 wlan_wep,wlan_scan_sta,ath_rate_sample,ath_pci, Live 0xf8537000 ath_hal 398604 3 ath_rate_sample,ath_pci, Live 0xf8480000 I've been at this for hours now, also tried ndiswrapper and ath5k drivers with no luck, and really could use some help. Cheers.

    Read the article

  • Cross-platform, human-readable, du on root partition that truly ignores other filesystems

    - by nice_line
    I hate this so much: Linux builtsowell 2.6.18-274.7.1.el5 #1 SMP Mon Oct 17 11:57:14 EDT 2011 x86_64 x86_64 x86_64 GNU/Linux df -kh Filesystem Size Used Avail Use% Mounted on /dev/mapper/mpath0p2 8.8G 8.7G 90M 99% / /dev/mapper/mpath0p6 2.0G 37M 1.9G 2% /tmp /dev/mapper/mpath0p3 5.9G 670M 4.9G 12% /var /dev/mapper/mpath0p1 494M 86M 384M 19% /boot /dev/mapper/mpath0p7 7.3G 187M 6.7G 3% /home tmpfs 48G 6.2G 42G 14% /dev/shm /dev/mapper/o10g.bin 25G 7.4G 17G 32% /app/SIP/logs /dev/mapper/o11g.bin 25G 11G 14G 43% /o11g tmpfs 4.0K 0 4.0K 0% /dev/vx lunmonster1q:/vol/oradb_backup/epmxs1q1 686G 507G 180G 74% /rpmqa/backup lunmonster1q:/vol/oradb_redo/bisxs1q1 4.0G 1.6G 2.5G 38% /bisxs1q/rdoctl1 lunmonster1q:/vol/oradb_backup/bisxs1q1 686G 507G 180G 74% /bisxs1q/backup lunmonster1q:/vol/oradb_exp/bisxs1q1 2.0T 1.1T 984G 52% /bisxs1q/exp lunmonster2q:/vol/oradb_home/bisxs1q1 10G 174M 9.9G 2% /bisxs1q/home lunmonster2q:/vol/oradb_data/bisxs1q1 52G 5.2G 47G 10% /bisxs1q/oradata lunmonster1q:/vol/oradb_redo/bisxs1q2 4.0G 1.6G 2.5G 38% /bisxs1q/rdoctl2 ip-address1:/vol/oradb_home/cspxs1q1 10G 184M 9.9G 2% /cspxs1q/home ip-address2:/vol/oradb_backup/cspxs1q1 674G 314G 360G 47% /cspxs1q/backup ip-address2:/vol/oradb_redo/cspxs1q1 4.0G 1.5G 2.6G 37% /cspxs1q/rdoctl1 ip-address2:/vol/oradb_exp/cspxs1q1 4.1T 1.5T 2.6T 37% /cspxs1q/exp ip-address2:/vol/oradb_redo/cspxs1q2 4.0G 1.5G 2.6G 37% /cspxs1q/rdoctl2 ip-address1:/vol/oradb_data/cspxs1q1 160G 23G 138G 15% /cspxs1q/oradata lunmonster1q:/vol/oradb_exp/epmxs1q1 2.0T 1.1T 984G 52% /epmxs1q/exp lunmonster2q:/vol/oradb_home/epmxs1q1 10G 80M 10G 1% /epmxs1q/home lunmonster2q:/vol/oradb_data/epmxs1q1 330G 249G 82G 76% /epmxs1q/oradata lunmonster1q:/vol/oradb_redo/epmxs1q2 5.0G 609M 4.5G 12% /epmxs1q/rdoctl2 lunmonster1q:/vol/oradb_redo/epmxs1q1 5.0G 609M 4.5G 12% /epmxs1q/rdoctl1 /dev/vx/dsk/slaxs1q/slaxs1q-vol1 183G 17G 157G 10% /slaxs1q/backup /dev/vx/dsk/slaxs1q/slaxs1q-vol4 173G 58G 106G 36% /slaxs1q/oradata /dev/vx/dsk/slaxs1q/slaxs1q-vol5 75G 952M 71G 2% /slaxs1q/exp /dev/vx/dsk/slaxs1q/slaxs1q-vol2 9.8G 381M 8.9G 5% /slaxs1q/home /dev/vx/dsk/slaxs1q/slaxs1q-vol6 4.0G 1.6G 2.2G 42% /slaxs1q/rdoctl1 /dev/vx/dsk/slaxs1q/slaxs1q-vol3 4.0G 1.6G 2.2G 42% /slaxs1q/rdoctl2 /dev/mapper/appoem 30G 1.3G 27G 5% /app/em Yet, I equally, if not quite a bit more, also hate this: SunOS solarious 5.10 Generic_147440-19 sun4u sparc SUNW,SPARC-Enterprise Filesystem size used avail capacity Mounted on kiddie001Q_rpool/ROOT/s10s_u8wos_08a 8G 7.7G 1.3G 96% / /devices 0K 0K 0K 0% /devices ctfs 0K 0K 0K 0% /system/contract proc 0K 0K 0K 0% /proc mnttab 0K 0K 0K 0% /etc/mnttab swap 15G 1.8M 15G 1% /etc/svc/volatile objfs 0K 0K 0K 0% /system/object sharefs 0K 0K 0K 0% /etc/dfs/sharetab fd 0K 0K 0K 0% /dev/fd kiddie001Q_rpool/ROOT/s10s_u8wos_08a/var 31G 8.3G 6.6G 56% /var swap 512M 4.6M 507M 1% /tmp swap 15G 88K 15G 1% /var/run swap 15G 0K 15G 0% /dev/vx/dmp swap 15G 0K 15G 0% /dev/vx/rdmp /dev/dsk/c3t4d4s0 3 20G 279G 41G 88% /fs_storage /dev/vx/dsk/oracle/ora10g-vol1 292G 214G 73G 75% /o10g /dev/vx/dsk/oec/oec-vol1 64G 33G 31G 52% /oec/runway /dev/vx/dsk/oracle/ora9i-vol1 64G 33G 31G 59% /o9i /dev/vx/dsk/home 23G 18G 4.7G 80% /export/home /dev/vx/dsk/dbwork/dbwork-vol1 292G 214G 73G 92% /db03/wk01 /dev/vx/dsk/oradg/ebusredovol 2.0G 475M 1.5G 24% /u21 /dev/vx/dsk/oradg/ebusbckupvol 200G 32G 166G 17% /u31 /dev/vx/dsk/oradg/ebuscrtlvol 2.0G 475M 1.5G 24% /u20 kiddie001Q_rpool 31G 97K 6.6G 1% /kiddie001Q_rpool monsterfiler002q:/vol/ebiz_patches_nfs/NSA0304 203G 173G 29G 86% /oracle/patches /dev/odm 0K 0K 0K 0% /dev/odm The people with the authority don't rotate logs or delete packages after install in my environment. Standards, remediation, cohesion...all fancy foreign words to me. ============== How am I supposed to deal with / filesystem full issues across multiple platforms that have a devastating number of mounts? On Red Hat el5, du -x apparently avoids traversal into other filesystems. While this may be so, it does not appear to do anything if run from the / directory. On Solaris 10, the equivalent flag is du -d, which apparently packs no surprises, allowing Sun to uphold its legacy of inconvenience effortlessly. (I'm hoping I've just been doing it wrong.) I offer up for sacrifice my Frankenstein's monster. Tell me how ugly it is. Tell me I should download forbidden 3rd party software. Tell me I should perform unauthorized coreutils updates, piecemeal, across 2000 systems, with no single sign-on, no authorized keys, and no network update capability. Then, please help me make this bastard better: pwd / du * | egrep -v "$(echo $(df | awk '{print $1 "\n" $5 "\n" $6}' | \ cut -d\/ -f2-5 | egrep -v "[0-9]|^$|Filesystem|Use|Available|Mounted|blocks|vol|swap")| \ sed 's/ /\|/g')" | egrep -v "proc|sys|media|selinux|dev|platform|system|tmp|tmpfs|mnt|kernel" | \ cut -d\/ -f1-2 | sort -k2 -k1,1nr | uniq -f1 | sort -k1,1n | cut -f2 | xargs du -shx | \ egrep "G|[5-9][0-9]M|[1-9][0-9][0-9]M" My biggest failure and regret is that it still requires a single character edit for Solaris: pwd / du * | egrep -v "$(echo $(df | awk '{print $1 "\n" $5 "\n" $6}' | \ cut -d\/ -f2-5 | egrep -v "[0-9]|^$|Filesystem|Use|Available|Mounted|blocks|vol|swap")| \ sed 's/ /\|/g')" | egrep -v "proc|sys|media|selinux|dev|platform|system|tmp|tmpfs|mnt|kernel" | \ cut -d\/ -f1-2 | sort -k2 -k1,1nr | uniq -f1 | sort -k1,1n | cut -f2 | xargs du -shd | \ egrep "G|[5-9][0-9]M|[1-9][0-9][0-9]M" This will exclude all non / filesystems in a du search from the / directory by basically munging an egrepped df from a second pipe-delimited egrep regex subshell exclusion that is naturally further excluded upon by a third egrep in what I would like to refer to as "the whale." The munge-fest frantically escalates into some xargs du recycling where -x/-d is actually useful, and a final, gratuitous egrep spits out a list of directories that almost feels like an accomplishment: Linux: 54M etc/gconf 61M opt/quest 77M opt 118M usr/ ##===\ 149M etc 154M root 303M lib/modules 313M usr/java ##====\ 331M lib 357M usr/lib64 ##=====\ 433M usr/lib ##========\ 1.1G usr/share ##=======\ 3.2G usr/local ##========\ 5.4G usr ##<=============Ascending order to parent 94M app/SIP ##<==\ 94M app ##<=======Were reported as 7gb and then corrected by second du with -x. Solaris: 63M etc 490M bb 570M root/cores.ric.20100415 1.7G oec/archive 1.1G root/packages 2.2G root 1.7G oec Guess what? It's really slow. Edit: Are there any bash one-liner heroes out there than can turn my bloated abomination into divine intervention, or at least something resembling gingerly copypasta?

    Read the article

  • External HDD USB 3.0 failure

    - by Philip
    [ 2560.376113] usb 9-1: new high-speed USB device number 2 using xhci_hcd [ 2560.376186] usb 9-1: Device not responding to set address. [ 2560.580136] usb 9-1: Device not responding to set address. [ 2560.784104] usb 9-1: device not accepting address 2, error -71 [ 2560.840127] hub 9-0:1.0: unable to enumerate USB device on port 1 [ 2561.080182] usb 10-1: new SuperSpeed USB device number 5 using xhci_hcd [ 2566.096163] usb 10-1: device descriptor read/8, error -110 [ 2566.200096] usb 10-1: new SuperSpeed USB device number 5 using xhci_hcd [ 2571.216175] usb 10-1: device descriptor read/8, error -110 [ 2571.376138] hub 10-0:1.0: unable to enumerate USB device on port 1 [ 2571.744174] usb 10-1: new SuperSpeed USB device number 7 using xhci_hcd [ 2576.760116] usb 10-1: device descriptor read/8, error -110 [ 2576.864074] usb 10-1: new SuperSpeed USB device number 7 using xhci_hcd [ 2581.880153] usb 10-1: device descriptor read/8, error -110 [ 2582.040123] hub 10-0:1.0: unable to enumerate USB device on port 1 [ 2582.224139] hub 9-0:1.0: unable to enumerate USB device on port 1 [ 2582.464177] usb 10-1: new SuperSpeed USB device number 9 using xhci_hcd [ 2587.480122] usb 10-1: device descriptor read/8, error -110 [ 2587.584079] usb 10-1: new SuperSpeed USB device number 9 using xhci_hcd [ 2592.600150] usb 10-1: device descriptor read/8, error -110 [ 2592.760134] hub 10-0:1.0: unable to enumerate USB device on port 1 [ 2593.128175] usb 10-1: new SuperSpeed USB device number 11 using xhci_hcd [ 2598.144183] usb 10-1: device descriptor read/8, error -110 [ 2598.248109] usb 10-1: new SuperSpeed USB device number 11 using xhci_hcd [ 2603.264171] usb 10-1: device descriptor read/8, error -110 [ 2603.480157] usb 10-1: new SuperSpeed USB device number 12 using xhci_hcd [ 2608.496162] usb 10-1: device descriptor read/8, error -110 [ 2608.600091] usb 10-1: new SuperSpeed USB device number 12 using xhci_hcd [ 2613.616166] usb 10-1: device descriptor read/8, error -110 [ 2613.832170] usb 10-1: new SuperSpeed USB device number 13 using xhci_hcd [ 2618.848135] usb 10-1: device descriptor read/8, error -110 [ 2618.952079] usb 10-1: new SuperSpeed USB device number 13 using xhci_hcd [ 2623.968155] usb 10-1: device descriptor read/8, error -110 [ 2624.184176] usb 10-1: new SuperSpeed USB device number 14 using xhci_hcd [ 2629.200124] usb 10-1: device descriptor read/8, error -110 [ 2629.304075] usb 10-1: new SuperSpeed USB device number 14 using xhci_hcd [ 2634.320172] usb 10-1: device descriptor read/8, error -110 [ 2634.424135] hub 10-0:1.0: unable to enumerate USB device on port 1 [ 2634.776186] usb 10-1: new SuperSpeed USB device number 15 using xhci_hcd [ 2639.792105] usb 10-1: device descriptor read/8, error -110 [ 2639.896090] usb 10-1: new SuperSpeed USB device number 15 using xhci_hcd [ 2644.912172] usb 10-1: device descriptor read/8, error -110 [ 2645.128174] usb 10-1: new SuperSpeed USB device number 16 using xhci_hcd [ 2650.144160] usb 10-1: device descriptor read/8, error -110 [ 2650.248062] usb 10-1: new SuperSpeed USB device number 16 using xhci_hcd [ 2655.264120] usb 10-1: device descriptor read/8, error -110 [ 2655.480182] usb 10-1: new SuperSpeed USB device number 17 using xhci_hcd [ 2660.496121] usb 10-1: device descriptor read/8, error -110 [ 2660.600086] usb 10-1: new SuperSpeed USB device number 17 using xhci_hcd [ 2665.616167] usb 10-1: device descriptor read/8, error -110 [ 2665.832177] usb 10-1: new SuperSpeed USB device number 18 using xhci_hcd [ 2670.848110] usb 10-1: device descriptor read/8, error -110 [ 2670.952066] usb 10-1: new SuperSpeed USB device number 18 using xhci_hcd [ 2675.968081] usb 10-1: device descriptor read/8, error -110 [ 2676.072124] hub 10-0:1.0: unable to enumerate USB device on port 1 [ 2786.104531] xhci_hcd 0000:02:00.0: remove, state 4 [ 2786.104546] usb usb10: USB disconnect, device number 1 [ 2786.104686] xHCI xhci_drop_endpoint called for root hub [ 2786.104692] xHCI xhci_check_bandwidth called for root hub [ 2786.104942] xhci_hcd 0000:02:00.0: USB bus 10 deregistered [ 2786.105054] xhci_hcd 0000:02:00.0: remove, state 4 [ 2786.105065] usb usb9: USB disconnect, device number 1 [ 2786.105176] xHCI xhci_drop_endpoint called for root hub [ 2786.105181] xHCI xhci_check_bandwidth called for root hub [ 2786.109787] xhci_hcd 0000:02:00.0: USB bus 9 deregistered [ 2786.110134] xhci_hcd 0000:02:00.0: PCI INT A disabled [ 2794.268445] pci 0000:02:00.0: [1b73:1000] type 0 class 0x000c03 [ 2794.268483] pci 0000:02:00.0: reg 10: [mem 0x00000000-0x0000ffff] [ 2794.268689] pci 0000:02:00.0: PME# supported from D0 D3hot [ 2794.268700] pci 0000:02:00.0: PME# disabled [ 2794.276383] pci 0000:02:00.0: BAR 0: assigned [mem 0xd7800000-0xd780ffff] [ 2794.276398] pci 0000:02:00.0: BAR 0: set to [mem 0xd7800000-0xd780ffff] (PCI address [0xd7800000-0xd780ffff]) [ 2794.276419] pci 0000:02:00.0: no hotplug settings from platform [ 2794.276658] xhci_hcd 0000:02:00.0: enabling device (0000 -> 0002) [ 2794.276675] xhci_hcd 0000:02:00.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 2794.276762] xhci_hcd 0000:02:00.0: setting latency timer to 64 [ 2794.276771] xhci_hcd 0000:02:00.0: xHCI Host Controller [ 2794.276913] xhci_hcd 0000:02:00.0: new USB bus registered, assigned bus number 9 [ 2794.395760] xhci_hcd 0000:02:00.0: irq 16, io mem 0xd7800000 [ 2794.396141] xHCI xhci_add_endpoint called for root hub [ 2794.396144] xHCI xhci_check_bandwidth called for root hub [ 2794.396195] hub 9-0:1.0: USB hub found [ 2794.396203] hub 9-0:1.0: 1 port detected [ 2794.396305] xhci_hcd 0000:02:00.0: xHCI Host Controller [ 2794.396371] xhci_hcd 0000:02:00.0: new USB bus registered, assigned bus number 10 [ 2794.396496] xHCI xhci_add_endpoint called for root hub [ 2794.396499] xHCI xhci_check_bandwidth called for root hub [ 2794.396547] hub 10-0:1.0: USB hub found [ 2794.396553] hub 10-0:1.0: 1 port detected [ 2798.004084] usb 1-3: new high-speed USB device number 8 using ehci_hcd [ 2798.140824] scsi21 : usb-storage 1-3:1.0 [ 2820.176116] usb 1-3: reset high-speed USB device number 8 using ehci_hcd [ 2824.000526] scsi 21:0:0:0: Direct-Access BUFFALO HD-PZU3 0001 PQ: 0 ANSI: 6 [ 2824.002263] sd 21:0:0:0: Attached scsi generic sg2 type 0 [ 2824.003617] sd 21:0:0:0: [sdb] 1953463728 512-byte logical blocks: (1.00 TB/931 GiB) [ 2824.005139] sd 21:0:0:0: [sdb] Write Protect is off [ 2824.005149] sd 21:0:0:0: [sdb] Mode Sense: 1f 00 00 08 [ 2824.009084] sd 21:0:0:0: [sdb] No Caching mode page present [ 2824.009094] sd 21:0:0:0: [sdb] Assuming drive cache: write through [ 2824.011944] sd 21:0:0:0: [sdb] No Caching mode page present [ 2824.011952] sd 21:0:0:0: [sdb] Assuming drive cache: write through [ 2824.049153] sdb: sdb1 [ 2824.051814] sd 21:0:0:0: [sdb] No Caching mode page present [ 2824.051821] sd 21:0:0:0: [sdb] Assuming drive cache: write through [ 2824.051825] sd 21:0:0:0: [sdb] Attached SCSI disk [ 2839.536624] usb 1-3: USB disconnect, device number 8 [ 2844.620178] usb 10-1: new SuperSpeed USB device number 2 using xhci_hcd [ 2844.640281] scsi22 : usb-storage 10-1:1.0 [ 2850.326545] scsi 22:0:0:0: Direct-Access BUFFALO HD-PZU3 0001 PQ: 0 ANSI: 6 [ 2850.327560] sd 22:0:0:0: Attached scsi generic sg2 type 0 [ 2850.329561] sd 22:0:0:0: [sdb] 1953463728 512-byte logical blocks: (1.00 TB/931 GiB) [ 2850.329889] sd 22:0:0:0: [sdb] Write Protect is off [ 2850.329897] sd 22:0:0:0: [sdb] Mode Sense: 1f 00 00 08 [ 2850.330223] sd 22:0:0:0: [sdb] No Caching mode page present [ 2850.330231] sd 22:0:0:0: [sdb] Assuming drive cache: write through [ 2850.331414] sd 22:0:0:0: [sdb] No Caching mode page present [ 2850.331423] sd 22:0:0:0: [sdb] Assuming drive cache: write through [ 2850.384116] usb 10-1: USB disconnect, device number 2 [ 2850.392050] sd 22:0:0:0: [sdb] Unhandled error code [ 2850.392056] sd 22:0:0:0: [sdb] Result: hostbyte=DID_NO_CONNECT driverbyte=DRIVER_OK [ 2850.392061] sd 22:0:0:0: [sdb] CDB: Read(10): 28 00 00 00 00 00 00 00 08 00 [ 2850.392074] end_request: I/O error, dev sdb, sector 0 [ 2850.392079] quiet_error: 70 callbacks suppressed [ 2850.392082] Buffer I/O error on device sdb, logical block 0 [ 2850.392194] ldm_validate_partition_table(): Disk read failed. [ 2850.392271] Dev sdb: unable to read RDB block 0 [ 2850.392377] sdb: unable to read partition table [ 2850.392581] sd 22:0:0:0: [sdb] READ CAPACITY failed [ 2850.392584] sd 22:0:0:0: [sdb] Result: hostbyte=DID_NO_CONNECT driverbyte=DRIVER_OK [ 2850.392588] sd 22:0:0:0: [sdb] Sense not available. [ 2850.392613] sd 22:0:0:0: [sdb] Asking for cache data failed [ 2850.392617] sd 22:0:0:0: [sdb] Assuming drive cache: write through [ 2850.392621] sd 22:0:0:0: [sdb] Attached SCSI disk [ 2850.732182] usb 10-1: new SuperSpeed USB device number 3 using xhci_hcd [ 2850.752228] scsi23 : usb-storage 10-1:1.0 [ 2851.752709] scsi 23:0:0:0: Direct-Access BUFFALO HD-PZU3 0001 PQ: 0 ANSI: 6 [ 2851.754481] sd 23:0:0:0: Attached scsi generic sg2 type 0 [ 2851.756576] sd 23:0:0:0: [sdb] 1953463728 512-byte logical blocks: (1.00 TB/931 GiB) [ 2851.758426] sd 23:0:0:0: [sdb] Write Protect is off [ 2851.758436] sd 23:0:0:0: [sdb] Mode Sense: 1f 00 00 08 [ 2851.758779] sd 23:0:0:0: [sdb] No Caching mode page present [ 2851.758787] sd 23:0:0:0: [sdb] Assuming drive cache: write through [ 2851.759968] sd 23:0:0:0: [sdb] No Caching mode page present [ 2851.759977] sd 23:0:0:0: [sdb] Assuming drive cache: write through [ 2851.817710] sdb: sdb1 [ 2851.820562] sd 23:0:0:0: [sdb] No Caching mode page present [ 2851.820568] sd 23:0:0:0: [sdb] Assuming drive cache: write through [ 2851.820572] sd 23:0:0:0: [sdb] Attached SCSI disk [ 2852.060352] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2852.076533] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2852.076538] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2852.196329] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2852.212593] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2852.212599] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2852.456290] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2852.472402] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2852.472408] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2852.624304] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2852.640531] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2852.640536] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2852.772296] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2852.788536] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2852.788541] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2852.920349] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2852.936536] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2852.936540] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2853.072287] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2853.088565] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2853.088570] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2884.176339] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2884.192561] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2884.192567] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2884.320349] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2884.336526] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2884.336531] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2884.468344] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2884.484551] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2884.484556] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2884.612349] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2884.628540] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2884.628545] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2884.756350] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2884.772528] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2884.772533] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2884.848116] usb 10-1: USB disconnect, device number 3 [ 2884.851493] scsi 23:0:0:0: [sdb] killing request [ 2884.851501] scsi 23:0:0:0: [sdb] killing request [ 2884.851699] scsi 23:0:0:0: [sdb] Unhandled error code [ 2884.851702] scsi 23:0:0:0: [sdb] Result: hostbyte=DID_NO_CONNECT driverbyte=DRIVER_OK [ 2884.851708] scsi 23:0:0:0: [sdb] CDB: Read(10): 28 00 00 5f 2b ee 00 00 3e 00 [ 2884.851721] end_request: I/O error, dev sdb, sector 6237166 [ 2884.851726] Buffer I/O error on device sdb1, logical block 6237102 [ 2884.851730] Buffer I/O error on device sdb1, logical block 6237103 [ 2884.851738] Buffer I/O error on device sdb1, logical block 6237104 [ 2884.851741] Buffer I/O error on device sdb1, logical block 6237105 [ 2884.851744] Buffer I/O error on device sdb1, logical block 6237106 [ 2884.851747] Buffer I/O error on device sdb1, logical block 6237107 [ 2884.851750] Buffer I/O error on device sdb1, logical block 6237108 [ 2884.851753] Buffer I/O error on device sdb1, logical block 6237109 [ 2884.851757] Buffer I/O error on device sdb1, logical block 6237110 [ 2884.851807] scsi 23:0:0:0: [sdb] Unhandled error code [ 2884.851810] scsi 23:0:0:0: [sdb] Result: hostbyte=DID_NO_CONNECT driverbyte=DRIVER_OK [ 2884.851813] scsi 23:0:0:0: [sdb] CDB: Read(10): 28 00 00 5f 2c 2c 00 00 3e 00 [ 2884.851824] end_request: I/O error, dev sdb, sector 6237228 [ 2885.168190] usb 10-1: new SuperSpeed USB device number 4 using xhci_hcd [ 2885.188268] scsi24 : usb-storage 10-1:1.0 Please help me with my problem. I got this after running dmesg.

    Read the article

< Previous Page | 40 41 42 43 44 45 46  | Next Page >