Search Results

Search found 2523 results on 101 pages for 'communication'.

Page 44/101 | < Previous Page | 40 41 42 43 44 45 46 47 48 49 50 51  | Next Page >

  • Accessing SQL Data Services via ADO.NET Data Service Client Library

    - by Mehmet Aras
    Is this possible? Basically I would like to use SQL Data Services REST interface and let the ADO.NET Data Service Client library handle communication details and generate the entities that I can use. I looked at the samples in February release of Azure services kit but the samples in there are using HttpWebRequest and HttpWebResponse to consume SQL Data Services RESTfully. I was hoping to use ADO.NET Data Service Client library to abstract low-level details away.

    Read the article

  • VS2010 Load Testing - Restricting ports

    - by marks-s
    As per the trouble shooting guide for VS2010 Load Testing (http://social.msdn.microsoft.com/Forums/en/vststest/thread/df043823-ffcf-46a4-9e47-1c4b8854ca13), I'm trying to restrict the range of ports used for client-controller communication. HKEY_LOCAL_MACHINE\SOFTWARE\MICROSOFT\VisualStudio\10.0\EnterpriseTools\QualityTools\ListenPortRange\PortRangeStart HKEY_LOCAL_MACHINE\SOFTWARE\MICROSOFT\VisualStudio\10.0\EnterpriseTools\QualityTools\ListenPortRange\PortRangeEnd I've set these keys on the client as described but according to netstat the client is still listening on random ports. The controller is attempting to communicate on the same random ports as the client. Anyone experienced the same?

    Read the article

  • H.264 over RTP - Identify SPS and PPS Frames

    - by Toby
    I have a raw H.264 Stream from an IP Camera packed in RTP frames. I want to get raw H.264 data into a file so I can convert it with ffmpeg. So when I want to write the data into my raw H.264 file I found out it has to look like this: 00 00 01 [SPS] 00 00 01 [PPS] 00 00 01 [NALByte] [PAYLOAD RTP Frame 1] // Payload always without the first 2 Bytes -> NAL [PAYLOAD RTP Frame 2] [... until PAYLOAD Frame with Mark Bit received] // From here its a new Video Frame 00 00 01 [NAL BYTE] [PAYLOAD RTP Frame 1] .... So I get the SPS and the PPS from the Session Description Protocol out of my preceding RTSP communication. Additionally the camera sends the SPS and the PPSin two single messages before starting with the video stream itself. So I capture the messages in this order: 1. Preceding RTSP Communication here ( including SDP with SPS and PPS ) 2. RTP Frame with Payload: 67 42 80 28 DA 01 40 16 C4 // This is the SPS 3. RTP Frame with Payload: 68 CE 3C 80 // This is the PPS 4. RTP Frame with Payload: ... // Video Data Then there come some Frames with Payload and at some point a RTP Frame with the Marker Bit = 1. This means ( if I got it right) that I have a complete video frame. Afer this I write the Prefix Sequence ( 00 00 01 ) and the NALfrom the payload again and go on with the same procedure. Now my camera sends me after every 8 complete Video Frames the SPS and the PPS again. ( Again in two RTP Frames, as seen in the example above ). I know that especially the PPS can change in between streaming but that's not the problem. My questions are now: 1. Do I need to write the SPS/PPS every 8th Video Frame? If my SPS and my PPS don't change it should be enough to have them written at the very beginning of my file and nothing more? 2. How to distinguish between SPS/PPS and normal RTP Frames? In my C++ Code which parses the transmitted data I need make a difference between the RTP Frames with normal Payload an the ones carrying the SPS/PPS. How can I distinguish them? Okay the SPS/PPS frames are usually way smaller, but that's not a save call to rely on. Because if I ignore them I need to know which data I can throw away, or if I need to write them I need to put the 00 00 01 Prefix in front of them. ? Or is it a fixed rule that they occur every 8th Video Frame?

    Read the article

  • how to connect to ethernet printer throught python?

    - by Prasanth
    How can i connect and send data to a Ethernet receipt printer Epson-T88V through python2.7, i have set the ipaddress of the Ethernet printer manually and the utility software communication is also successful. How do i detect and connect to these printers and send data to print. Is there and module for Ethernet connection in python. Using more than one Ethernet printer and separate data to be printed simultaneously from a single system, i am using windows xp and python 2.7 hope i am clear Thanks.

    Read the article

  • realtime diagnostics

    - by Ion Todirel
    I have an application which has a loop, part of a "Scheduler", which runs at all time and is the heart of the application. Pretty much like a game loop, just that my application is a WPF application and it's not a game. Naturally the application does logging at many points, but the Scheduler does some sensitive monitoring, and sometimes it's impossible just from the logs to tell what may have gotten wrong (and by wrong I don't mean exceptions) or the current status. Because Scheduler's inner loop runs at short intervals, you can't do file I/O-based logging (or using the Event Viewer) in there. First, you need to watch it in real-time, and secondly the log file would grow in size very fast. So I was thinking of ways to show this data to the user in the realtime, some things I considered: Display the data in realtime in the UI Use AllocConsole/WriteConsole to display this information in a console Use a different console application which would display this information, communicate between the Scheduler and the console app using pipes or other IPC techniques Use Windows' Performance Monitor and somehow feed it with this information ETW Displaying in the UI would have its issues. First it doesn't integrate with the UI I had in mind for my application, and I don't want to complicate the UI just for this. This diagnostics would only happen rarely. Secondly, there is going to be some non-trivial data protection, as the Scheduler has it's own thread. A separate console window would work probably, but I'm still worried if it's not too much threshold. Allocating my own console, as this is a windows app, would probably be better than a different console application (3), as I don't need to worry about IPC communication, and non-blocking communication. However a user could close the console I allocated, and it would be problematic in that case. With a separate process you don't have to worry about it. Assuming there is an API for Performance Monitor, it wouldn't be integrated too well with my app or apparent to the users. Using ETW also doesn't solve anything, just a random idea, I still need to display this information somehow. What others think, would there be other ways I missed?

    Read the article

  • Sending multiline message via sockets without closing the connection

    - by Yasir Arsanukaev
    Hello folks. Currently I have this code of my client-side Haskell application: import Network.Socket import Network.BSD import System.IO hiding (hPutStr, hPutStrLn, hGetLine, hGetContents) import System.IO.UTF8 connectserver :: HostName -- ^ Remote hostname, or localhost -> String -- ^ Port number or name -> IO Handle connectserver hostname port = withSocketsDo $ do -- withSocketsDo is required on Windows -- Look up the hostname and port. Either raises an exception -- or returns a nonempty list. First element in that list -- is supposed to be the best option. addrinfos <- getAddrInfo Nothing (Just hostname) (Just port) let serveraddr = head addrinfos -- Establish a socket for communication sock <- socket (addrFamily serveraddr) Stream defaultProtocol -- Mark the socket for keep-alive handling since it may be idle -- for long periods of time setSocketOption sock KeepAlive 1 -- Connect to server connect sock (addrAddress serveraddr) -- Make a Handle out of it for convenience h <- socketToHandle sock ReadWriteMode -- Were going to set buffering to LineBuffering and then -- explicitly call hFlush after each message, below, so that -- messages get logged immediately hSetBuffering h LineBuffering return h sendid :: Handle -> String -> IO String sendid h id = do hPutStr h id -- Make sure that we send data immediately hFlush h -- Retrieve results hGetLine h The code portions in connectserver are from this chapter of Real World Haskell book where they say: When dealing with TCP data, it's often convenient to convert a socket into a Haskell Handle. We do so here, and explicitly set the buffering – an important point for TCP communication. Next, we set up lazy reading from the socket's Handle. For each incoming line, we pass it to handle. After there is no more data – because the remote end has closed the socket – we output a message about that. Since hGetContents blocks until the server closes the socket on the other side, I used hGetLine instead. It satisfied me before I decided to implement multiline output to client. I wouldn't like the server to close a socket every time it finishes sending multiline text. The only simple idea I have at the moment is to count the number of linefeeds and stop reading lines after two subsequent linefeeds. Do you have any better suggestions? Thanks.

    Read the article

  • error to send SMS

    - by deni
    i have a problem with that code.. i got a error when i execute CommSetting.comm.SendMessage(pdu); the error is Phone reports generic communication error or syntax error can u tell me how to solve my problem?? thx i develop with c#, VS 2008

    Read the article

  • stunnel on window for IBM MQ connection

    - by user171523
    Does anyone have an experience or just thoughts about securing MQ TCP communication channels using stunnel? I am integration with third party S.W which has MQ support built in but it can not support SSL. So to have some kind of security over the TCP we would like to use stunnel. Does any one have any thoughts how to implement and any best practices

    Read the article

  • Hessian on Windows Phone 7/ Silverlight ??

    - by Michal
    Hi, I'm using hessian protocol for communication betwee server (java) and various client applications. Now I started to develop Windows Phone 7 client. I downloaded hessian C# implementation but it does not compile for windows phone 7/silverlight. Does anyone managed to make it work on WP7/Silverlight? It's looks like there is many thing to be done/changed to make it work, which I'd like to avoid if it has been done by someone already. Thanks.

    Read the article

  • Robust and easy to implement serial bus (automotive application)

    - by JcMaco
    What serial communication bus would you use in a automotive embedded system if your main selection criteria were: * Electrically robust * Slow speed (32 kb/s) * Easy to program * Easy to interface with microcontrollers It won't be transferring much data, but it will need to be transferred periodically at high speed (100 - 500 Hz). I find that RS-232 is just not reliable enough if you have noise in your ground line. CAN-bus seems interesting, but I have no experience with it. We are currently interested in a combination of AVR AT90CAN128 microcontrollers.

    Read the article

  • Arduino wireless options

    - by user541597
    I am currently working on a wireless solution for my arduino and computer. I am trying to connect a Transmitter to my computer and a receiver to my arduino. I have seen a lot of examples with arduino to arduino communication but none for computer to arduino. What would I need to interface the transmitter with my computer, PIC? If anyone can provide any insight or any links it would be greatly appreciated. Thanks,

    Read the article

  • Ajax In Firefox Plugin

    - by Jishnu
    Hi, Is there any way to send Ajax request to server from Firefox plugin? If yes how? If no, how do we have client server communication in Firefox plugin? I want to get some json data from server and manipulate dom object according to the client input. I am pretty beginner in plugin programming Regards, Jishnu

    Read the article

  • C# problem with two threads and hardware access

    - by mack369
    I'm creating an application which communicates with the device via FT2232H USB/RS232 converter. For communication I'm using FTD2XX_NET.dll library from FTDI website. I'm using two threads: first thread continuously reads data from the device the second thread is the main thread of the Windows Form Application I've got a problem when I'm trying to write any data to the device while the receiver's thread is running. The main thread simply hangs up on ftdiDevice.Write function. I tried to synchronize both threads so that only one thread can use Read/Write function at the same time, but it didn't help. Below code responsible for the communication. Note that following functions are methods of FtdiPort class. Receiver's thread private void receiverLoop() { if (this.DataReceivedHandler == null) { throw new BackendException("dataReceived delegate is not set"); } FTDI.FT_STATUS ftStatus = FTDI.FT_STATUS.FT_OK; byte[] readBytes = new byte[this.ReadBufferSize]; while (true) { lock (FtdiPort.threadLocker) { UInt32 numBytesRead = 0; ftStatus = ftdiDevice.Read(readBytes, this.ReadBufferSize, ref numBytesRead); if (ftStatus == FTDI.FT_STATUS.FT_OK) { this.DataReceivedHandler(readBytes, numBytesRead); } else { Trace.WriteLine(String.Format("Couldn't read data from ftdi: status {0}", ftStatus)); Thread.Sleep(10); } } Thread.Sleep(this.RXThreadDelay); } } Write function called from main thread public void Write(byte[] data, int length) { if (this.IsOpened) { uint i = 0; lock (FtdiPort.threadLocker) { this.ftdiDevice.Write(data, length, ref i); } Thread.Sleep(1); if (i != (int)length) { throw new BackendException("Couldnt send all data"); } } else { throw new BackendException("Port is closed"); } } Object used to synchronize two threads static Object threadLocker = new Object(); Method that starts the receiver's thread private void startReceiver() { if (this.DataReceivedHandler == null) { return; } if (this.IsOpened == false) { throw new BackendException("Trying to start listening for raw data while disconnected"); } this.receiverThread = new Thread(this.receiverLoop); //this.receiverThread.Name = "protocolListener"; this.receiverThread.IsBackground = true; this.receiverThread.Start(); } The ftdiDevice.Write function doesn't hang up if I comment following line: ftStatus = ftdiDevice.Read(readBytes, this.ReadBufferSize, ref numBytesRead);

    Read the article

  • What's the right way to communicate between 2 or more .Net applications running on a same computer w

    - by Ivan
    If my applications run on a same computer or even on different computers in a same LAN and need intense and quick communication, it seems illogical for me to use text-encoded web services and HTTP. I could possibly use IP/TCP/UDP sockets and invent my own protocols, but believe there is a standard way for .Net applications to send/receive object instances (and, maybe, even sharing an object by reference?). Can you tell me what's that standard way? I am only interested in .Net Framework 4 applications and don't need to support legacy frameworks.

    Read the article

  • How do I implement TimeOut in idarkstar?

    - by malik
    Hi, A little background on the question: I am developing a RedDwarf(http://reddwarfserver.org/) client on iphone, for the client/server communication I use idarkstar. I had to make minor modifications to make it work till now. So here's the question, if the server is taking to long to respond or the network is very slow, how do I add a timeout functionality to make sure it doesn't keep waiting on the server forever? appreciate any pointers.

    Read the article

< Previous Page | 40 41 42 43 44 45 46 47 48 49 50 51  | Next Page >