  • boolean in java: what am I doing wrong?

    - by Cheesegraterr
    Hello, I am trying to make my boolean value work. I am new at programming java so I must be missing something simple. I am trying to make it so that if one of the tire pressures is below 35 or over 45 the system outputs "bad inflation" For class me must use a boolean which is what I tried. I cant figure out why this isnt working. No matter what I do the boolean is always true. Any tips? public class tirePressure { private static double getDoubleSystem1 () //Private routine to simply read a double in from the command line { String myInput1 = null; //Store the string that is read form the command line double numInput1 = 0; //Used to store the converted string into an double BufferedReader mySystem; //Buffer to store input mySystem = new BufferedReader (new InputStreamReader (System.in)); // creates a connection to system files or cmd try { myInput1 = mySystem.readLine (); //reads in data from console myInput1 = myInput1.trim (); //trim command cuts off unneccesary inputs } catch (IOException e) //checks for errors { System.out.println ("IOException: " + e); return -1; } numInput1 = Double.parseDouble (myInput1); //converts the string to an double return numInput1; //return double value to main program } static public void main (String[] args) { double TireFR; //double to store input from console double TireFL; double TireBR; double TireBL; boolean goodPressure; goodPressure = false; System.out.println ("Tire Pressure Checker"); System.out.println (" "); System.out.print ("Enter pressure of front left tire:"); TireFL = getDoubleSystem1 (); //read in an double from the user if (TireFL < 35 || TireFL > 45) { System.out.println ("Pressure out of range"); goodPressure = false; } System.out.print ("Enter pressure of front right tire:"); TireFR = getDoubleSystem1 (); //read in an double from the user if (TireFR < 35 || TireFR > 45) { System.out.println ("Pressure out of range"); goodPressure = false; } if (TireFL == TireFR) System.out.print (" "); else System.out.println ("Front tire pressures do not match"); System.out.println (" "); System.out.print ("Enter pressure of back left tire:"); TireBL = getDoubleSystem1 (); //read in an double from the user if (TireBL < 35 || TireBL > 45) { System.out.println ("Pressure out of range"); goodPressure = false; } System.out.print ("Enter pressure of back right tire:"); TireBR = getDoubleSystem1 (); //read in an double from the user if (TireBR < 35 || TireBR > 45) { System.out.println ("Pressure out of range"); goodPressure = false; } if (TireBL == TireBR) System.out.print (" "); else System.out.println ("Back tire pressures do not match"); if (goodPressure = true) System.out.println ("Inflation is OK."); else System.out.println ("Inflation is BAD."); System.out.println (goodPressure); } //mainmethod } // tirePressure Class

    Read the article

  • Implementing Unit Testing with the iPhone SDK

    - by ing0
    Hi, So I've followed this tutorial to setup unit testing on my app when I got a little stuck. At bullet point 8 in that tutorial it shows this image, which is what I should be expecting when I build: However this isn't what I get when I build. I get this error message: Command /bin/sh failed with exit code 1 as well as the error message the unit test has created. Then, when I expand on the first error I get this: PhaseScriptExecution "Run Script" "build/3D Pool.build/Debug-iphonesimulator/LogicTests.build/Script-1A6BA6AE10F28F40008AC2A8.sh" cd "/Users/james/Desktop/FYP/3D Pool" setenv ACTION build setenv ALTERNATE_GROUP staff ... setenv XCODE_VERSION_MAJOR 0300 setenv XCODE_VERSION_MINOR 0320 setenv YACC /Developer/usr/bin/yacc /bin/sh -c "\"/Users/james/Desktop/FYP/3D Pool/build/3D Pool.build/Debug-iphonesimulator/LogicTests.build/Script-1A6BA6AE10F28F40008AC2A8.sh\"" /Developer/Tools/RunPlatformUnitTests.include:412: note: Started tests for architectures 'i386' /Developer/Tools/RunPlatformUnitTests.include:419: note: Running tests for architecture 'i386' (GC OFF) objc[12589]: GC: forcing GC OFF because OBJC_DISABLE_GC is set Test Suite '/Users/james/Desktop/FYP/3D Pool/build/Debug-iphonesimulator/LogicTests.octest(Tests)' started at 2010-01-04 21:05:06 +0000 Test Suite 'LogicTests' started at 2010-01-04 21:05:06 +0000 Test Case '-[LogicTests testFail]' started. /Users/james/Desktop/FYP/3D Pool/LogicTests.m:17: error: -[LogicTests testFail] : Must fail to succeed. Test Case '-[LogicTests testFail]' failed (0.000 seconds). Test Suite 'LogicTests' finished at 2010-01-04 21:05:06 +0000. Executed 1 test, with 1 failure (0 unexpected) in 0.000 (0.000) seconds Test Suite '/Users/james/Desktop/FYP/3D Pool/build/Debug-iphonesimulator/LogicTests.octest(Tests)' finished at 2010-01-04 21:05:06 +0000. Executed 1 test, with 1 failure (0 unexpected) in 0.000 (0.002) seconds /Developer/Tools/RunPlatformUnitTests.include:448: error: Failed tests for architecture 'i386' (GC OFF) /Developer/Tools/RunPlatformUnitTests.include:462: note: Completed tests for architectures 'i386' Command /bin/sh failed with exit code 1 Now this is very odd as it is running the tests (and succeeding as you can see my STFail firing) because if I add a different test which passes I get no errors, so the tests are working fine. But why am I getting this extra build fail? It may also be of note that when downloading solutions/templates which should work out the box, I get the same error. I'm guessing I've set something up wrong here but I've just followed a tutorial 100% correctly!! If anyone could help I'd be very grateful! Thanks EDIT: According to this blog, this post and a few other websites, I'm not the only one getting this problem. It has been like this since the release of xCode 3.2, assuming the apple dev center documents and tutorials etc are pre-3.2 as well. However some say its a known issue whereas others seem to think this was intentional. I for one would like both the extended console and in code messages, and I certainly do not like the "Command /bin/sh..." error and really think they would have documented such an update. Hopefully it will be fixed soon anyway. UPDATE: Here's confirmation it's something changed since the release of xCode 3.2.1. This image: is from my test build using 3.2.1. This one is from an older version (3.1.4): . (The project for both was unchanged). Edit: Image URLS updated.

    Read the article

  • Forms bound to updateable ADO recordsets are not updateable when the source includes a JOIN

    - by Art
    I'm developing an application in Access 2007. It uses an .accdb front end connecting to an SQL Server 2005 backend. I use forms that are bound to ADO recordsets at runtime. For the sake of efficiency, the recordsets usually contain only one record, and are queried out on the server: Public Sub SetUpFormRecordset(cn As ADODB.Connection, rstIn As ADODB.Recordset, rstSource As String) Dim cmd As ADODB.Command Dim I As Long Set cmd = New ADODB.Command cn.Errors.Clear ' Recordsets based on command object Execute method are Read Only! With cmd Set .ActiveConnection = cn .CommandType = adCmdText .CommandText = rstSource End With With rstIn .CursorType = adOpenKeyset .LockType = adLockPessimistic 'Check the locktype after opening; optimistic locking is worthless on a bound End With ' form, and ADO might open optimistically without firing an error! rstIn.Open cmd, , adOpenKeyset, adLockPessimistic 'This should run the query on the server and return an updatable recordset With cn If .Errors.Count <> 0 Then For Each errADO In .Errors Call HandleADOErrors(.Errors(I)) I = I + 1 Next errADO End If End With End Sub rstSource (the string containg the TSQL on which the recordset is based) is assembled by the calling routine, in this case from the Open event of the form being bound: Private Sub Form_Open(Cancel As Integer) Dim rst As ADODB.Recordset Dim strSource As String, DefaultSource as String Dim lngID As Long lngID = Forms!MyParent.CurrentID strSource = "SELECT TOP (100) PERCENT dbo.Customers.CustomerID, dbo.Customers.LegacyID, dbo.Customers.Active, dbo.Customers.TypeID, dbo.Customers.Category, " & _ "dbo.Customers.Source, dbo.Customers.CustomerName, dbo.Customers.CustAddrID, dbo.Customers.Email, dbo.Customers.TaxExempt, dbo.Customers.SalesTaxCode, " & _ "dbo.Customers.SalesTax2Code, dbo.Customers.CreditLimit, dbo.Customers.CreationDate, dbo.Customers.FirstOrder, dbo.Customers.LastOrder, " & _ "dbo.Customers.nOrders, dbo.Customers.Concurrency, dbo.Customers.LegacyLN, dbo.Addresses.AddrType, dbo.Addresses.AddrLine1, dbo.Addresses.AddrLine2, " & _ "dbo.Addresses.City, dbo.Addresses.State, dbo.Addresses.Country, dbo.Addresses.PostalCode, dbo.Addresses.PhoneLandline, dbo.Addresses.Concurrency " & _ "FROM dbo.Customers INNER JOIN " & _ "dbo.Addresses ON dbo.Customers.CustAddrID = dbo.Addresses.AddrID " strSource = strSource & "WHERE dbo.Customers.CustomerID= " & lngID With Me 'Default is Set up for editing one record If Not Nz(.RecordSource, vbNullString) = vbNullString Then If .Dirty Then .Dirty = False 'Save any changes on the form .RecordSource = vbNullString End If If rst Is Nothing Then 'Might not be first time through DefaultSource = .RecordSource Else rst.Close Set rst = Nothing End If End With Set rst = New ADODB.Recordset Call setupformrecordset(dbconn, rst, strSource) 'dbconn is a global variable With Me Set .Recordset = rst End With End Sub The recordset that is returned from setupformrecordset is fully updateable, and its .Supports property shows this. It can be edited and updated in code. The entire form, however, is read only, even though it's .AllowEdits and .AllowAdditions properties are both true. Even the fields from the right hand side (the 'many' side) cannot be edited. Removing the INNER JOIN clause from the TSQL (restricting strSource to one table) makes the form fully editable. I've verified that the TSQL includes priimary key fields from both tables, and each table includes a timestamp field for concurrency. I tried changing the .CursorType and .CursorLocation properties of the recordset to no avail. What am I doing wrong?

    Read the article

  • Run unit tests in Jenkins / Hudson in automated fashion from dev to build server

    - by Kevin Donde
    We are currently running a Jenkins (Hudson) CI server to build and package our .net web projects and database projects. Everything is working great but I want to start writing unit tests and then only passing the build if the unit tests pass. We are using the built in msbuild task to build the web project. With the following arguments ... MsBuild Version .NET 4.0 MsBuild Build File ./WebProjectFolder/WebProject.csproj Command Line Arguments ./target:Rebuild /p:Configuration=Release;DeployOnBuild=True;PackageLocation=".\obj\Release\WebProject.zip";PackageAsSingleFile=True We need to run automated tests over our code that run automatically when we build on our machines (post build event possibly) but also run when Jenkins does a build for that project. If you run it like this it doesn't build the unit tests project because the web project doesn't reference the test project. The test project would reference the web project but I'm pretty sure that would be butchering our automated builds as they exist primarily to build and package our deployments. Running these tests should be a step in that automated build and package process. Options ... Create two Jenkins jobs. one to run the tests ... if the tests pass another build is triggered which builds and packages the web project. Put the post build event on the test project. Build the solution instead of the project (make sure the solution contains the required tests) and put post build events on any test projects that would run the nunit console to run the tests. Then use the command line to copy all the required files from each of the bin and content directories into a package. Just build the test project in jenkins instead of the web project in jenkins. The test project would reference the web project (depending on what you're testing) and build it. Problems ... There's two jobs and not one. Two things to debug not one. One to see if the tests passed and one to build and compile the web project. The tests could pass but the build could fail if its something that isn't used by what you're testing ... This requires us to know exactly what goes into the build. Right now msbuild does it all for us. If you have multiple teams working on a project everytime an extra folder is created you have to worry about the possibly brittle command line statements. This seems like a corruption of our main purpose here. The tests should be a step in this process not the overriding most important thing in this process. I'm also not 100% sure that a triggered build is the same as a normal build does it do all the same things as a normal build. Move all the correct files in the same way move them all into the same directories etc. Initial problem. We want to run our tests whenever our main project is built. But adding a post build event to the web project that runs against the test project doesn't work because the web project doesn't reference the test project and won't trigger a build of this project. I could go on ... but that's enough ... We've spent about a week trying to make this work nicely but haven't succeeded. Feel free to edit this if you feel you can get a better response ...

    Read the article

  • Binary data from a serial port in linux using c

    - by user1680393
    I am reading binary data from a serial port on Phidget sbc using Linux to get a command from an application running on a PC. I wrote a test program in VB to read the data into a byte array and convert it to decimal to use it but can’t figure out how to do it in c. I am unable to come up with anything with the research I have done on the internet. Command sent from PC is 0x0F. To check if I am getting correct data I read the data and send it back. Here is what I get back. Returned data has a carriage return added to it. Hex Display 0F00 0000 0D ‘\’ Display \0F\00\00\00\r Normal display just display a strange character. This tells me that the data is there that I can use, but can’t figure out to extract the value 0F or 15. How can I convert the incoming data to use it? I tried converting the received data using strtol, but it returns 0. I also tried setting the port to raw but it did not make any difference. unsigned char buffer1[1]; int ReadPort1() { int result; result = read(file1, &buffer1,1); if(result > 0) { WritePort1(buffer1); sprintf(tempstr, "Port1 data %s %d", buffer1, result); DisplayText(2,tempstr); } return result; } Port Open/Setup void OpenPort1() { //file1 = open("/dev/ttyUSB1", O_RDWR | O_NOCTTY | O_NONBLOCK); file1 = open("/dev/ttyUSB1", O_RDWR | O_NOCTTY | O_NODELAY); if(file1 < 0) printf("Error opening serial port1.\n"); else { SetPort(file1, 115200, 8, 1, 0, 1); port1open = 1; } } void SetPort(int fd, int Baud_Rate, int Data_Bits, int Stop_Bits, int Parity, int raw) { long BAUD; // derived baud rate from command line long DATABITS; long STOPBITS; long PARITYON; long PARITY; struct termios newtio; switch (Baud_Rate) { case 115200: BAUD = B115200; break; case 38400: BAUD = B38400; break; case 19200: BAUD = B19200; break; case 9600: BAUD = B9600; break; } //end of switch baud_rate switch (Data_Bits) { case 8: default: DATABITS = CS8; break; case 7: DATABITS = CS7; break; case 6: DATABITS = CS6; break; case 5: DATABITS = CS5; break; } //end of switch data_bits switch (Stop_Bits) { case 1: default: STOPBITS = 0; break; case 2: STOPBITS = CSTOPB; break; } //end of switch stop bits switch (Parity) { case 0: default: //none PARITYON = 0; PARITY = 0; break; case 1: //odd PARITYON = PARENB; PARITY = PARODD; break; case 2: //even PARITYON = PARENB; PARITY = 0; break; } //end of switch parity newtio.c_cflag = BAUD | DATABITS | STOPBITS | PARITYON | PARITY | CLOCAL | CREAD; newtio.c_iflag = IGNPAR; if(raw == 1) { newtio.c_oflag &= ~OPOST; newtio.c_lflag &= ~(ICANON | ECHO | ECHOE | ISIG); } else { newtio.c_lflag = 0; //ICANON; newtio.c_oflag = 0; } newtio.c_cc[VMIN]=1; newtio.c_cc[VTIME]=0; tcflush(fd, TCIFLUSH); tcsetattr(fd,TCSANOW,&newtio); }

    Read the article

  • Help to restructure my Doc/View more correctly

    - by Harvey
    Edited by OP. My program is in need of a lot of cleanup and restructuring. In another post I asked about leaving the MFC DocView framework and going to the WinProc & Message Loop way (what is that called for short?). Well at present I am thinking that I should clean up what I have in Doc View and perhaps later convert to non-MFC it that even makes sense. My Document class currently has almost nothing useful in it. I think a place to start is the InitInstance() function (posted below). In this part: POSITION pos=pDocTemplate->GetFirstDocPosition(); CLCWDoc *pDoc=(CLCWDoc *)pDocTemplate->GetNextDoc(pos); ASSERT_VALID(pDoc); POSITION vpos=pDoc->GetFirstViewPosition(); CChildView *pCV=(CChildView *)pDoc->GetNextView(vpos); This seem strange to me. I only have one doc and one view. I feel like I am going about it backwards with GetNextDoc() and GetNextView(). To try to use a silly analogy; it's like I have a book in my hand but I have to look up in it's index to find out what page the Title of the book is on. I'm tired of feeling embarrassed about my code. I either need correction or reassurance, or both. :) Also, all the miscellaneous items are in no particular order. I would like to rearrange them into an order that may be more standard, structured or straightforward. ALL suggestions welcome! BOOL CLCWApp::InitInstance() { InitCommonControls(); if(!AfxOleInit()) return FALSE; // Initialize the Toolbar dll. (Toolbar code by Nikolay Denisov.) InitGuiLibDLL(); // NOTE: insert GuiLib.dll into the resource chain SetRegistryKey(_T("Real Name Removed")); // Register document templates CSingleDocTemplate* pDocTemplate; pDocTemplate = new CSingleDocTemplate( IDR_MAINFRAME, RUNTIME_CLASS(CLCWDoc), RUNTIME_CLASS(CMainFrame), RUNTIME_CLASS(CChildView)); AddDocTemplate(pDocTemplate); // Parse command line for standard shell commands, DDE, file open CCmdLineInfo cmdInfo; ParseCommandLine(cmdInfo); // Dispatch commands specified on the command line // The window frame appears on the screen in here. if (!ProcessShellCommand(cmdInfo)) { AfxMessageBox("Failure processing Command Line"); return FALSE; } POSITION pos=pDocTemplate->GetFirstDocPosition(); CLCWDoc *pDoc=(CLCWDoc *)pDocTemplate->GetNextDoc(pos); ASSERT_VALID(pDoc); POSITION vpos=pDoc->GetFirstViewPosition(); CChildView *pCV=(CChildView *)pDoc->GetNextView(vpos); if(!cmdInfo.m_Fn1.IsEmpty() && !cmdInfo.m_Fn2.IsEmpty()) { pCV->OpenF1(cmdInfo.m_Fn1); pCV->OpenF2(cmdInfo.m_Fn2); pCV->DoCompare(); // Sends a paint message when complete } // enable file manager drag/drop and DDE Execute open m_pMainWnd->DragAcceptFiles(TRUE); m_pMainWnd->ShowWindow(SW_SHOWNORMAL); m_pMainWnd->UpdateWindow(); // paints the window background pCV->bDoSize=true; //Prevent a dozen useless size calculations return TRUE; } Thanks

    Read the article

  • Looking for best practise for writing a serial device communication app in C#

    - by cdotlister
    I am pretty new to serial comms, but would like advise on how to best achieve a robust application which speak to and listens to a serial device. I have managed to make use of System.IO.serialport, and successfully connected to, sent data to and recieved from my device. The way things work is this. My application connects to the Com Port and opens the port.... I then connect my device to the com port, and it detects a connectio to the PC, so sends a bit of text. it's really just copyright info, as well as the version of the firmware. I don't do anything with that, except display it in my 'activity' window. The device then waits. I can then query information, but sending a command such as 'QUERY PARAMETER1'. It then replies with something like: 'QUERY PARAMETER1\r\n\r\n76767\r\n\r\n' I then process that. I can then update it by sending 'SET PARAMETER1 12345', and it will reply with 'QUERY PARAMETER1\r\n\r\n12345\r\n\r\n'. All pretty basic. So, what I have done is created a Communication Class. this call is called in it's own thread, and sends data back to the main form... and also allows me to send messages to it. Sending data is easy. Recieving is a bit more tricky. I have employed the use of the datarecieved event, and when ever data comes in, I echo that to my screen. My problem is this: When I send a command, I feel I am being very dodgy in my handling. What I am doing is, lets say I am sending 'QUERY PARAMETER1'. I send the command to the device, I then put 'PARAMETER1' into a global variable, and I do a Thread.Sleep(100). On the data recieved, I then have a bit of logic that checks the incoming data, and sees if the string CONTAINS the value in the gloabl variable. As the reply may be 'QUERY PARAMETER1\r\n\r\n76767\r\n\r\n', it sees that it contains my parameter, parses the string, and returns the value I am looking for, but placing it into another global variable. My sending method was sleeping for 100ms. It then wakes, and checks the returned global variable. If it has data... then I'm happy, and I process the data. Problem is... if the sleep is too short.. it will fail. And I feel it's flakey.. putting stuff into variables.. then waiting... The other option is to use ReadLine instead, but that's very blocking. So I remove the datarecieved method, and instead... just send the data... then call ReadLine(). That may give me better results. There's no time, except when we connect initially, that data comes from the device, without me requesting it. So, maybe readline will be simpler and safer? Is this known as 'Blocking' reads? Also, can I set a timeout? Hopefully someone can guide me.

    Read the article

  • Looking for best practise for writing a serial device communication app

    - by cdotlister
    I am pretty new to serial comms, but would like advise on how to best achieve a robust application which speak to and listens to a serial device. I have managed to make use of System.IO.SerialPort, and successfully connected to, sent data to and recieved from my device. The way things work is this. My application connects to the Com Port and opens the port.... I then connect my device to the com port, and it detects a connection to the PC, so sends a bit of text. it's really just copyright info, as well as the version of the firmware. I don't do anything with that, except display it in my 'activity' window. The device then waits. I can then query information, but sending a command such as 'QUERY PARAMETER1'. It then replies with something like: 'QUERY PARAMETER1\r\n\r\n76767\r\n\r\n' I then process that. I can then update it by sending 'SET PARAMETER1 12345', and it will reply with 'QUERY PARAMETER1\r\n\r\n12345\r\n\r\n'. All pretty basic. So, what I have done is created a Communication Class. this call is called in it's own thread, and sends data back to the main form... and also allows me to send messages to it. Sending data is easy. Recieving is a bit more tricky. I have employed the use of the datarecieved event, and when ever data comes in, I echo that to my screen. My problem is this: When I send a command, I feel I am being very dodgy in my handling. What I am doing is, lets say I am sending 'QUERY PARAMETER1'. I send the command to the device, I then put 'PARAMETER1' into a global variable, and I do a Thread.Sleep(100). On the data received, I then have a bit of logic that checks the incoming data, and sees if the string CONTAINS the value in the global variable. As the reply may be 'QUERY PARAMETER1\r\n\r\n76767\r\n\r\n', it sees that it contains my parameter, parses the string, and returns the value I am looking for, but placing it into another global variable. My sending method was sleeping for 100ms. It then wakes, and checks the returned global variable. If it has data... then I'm happy, and I process the data. Problem is... if the sleep is too short.. it will fail. And I feel it's flaky.. putting stuff into variables.. then waiting... The other option is to use ReadLine instead, but that's very blocking. So I remove the data received method, and instead... just send the data... then call ReadLine(). That may give me better results. There's no time, except when we connect initially, that data comes from the device, without me requesting it. So, maybe ReadLine will be simpler and safer? Is this known as 'Blocking' reads? Also, can I set a timeout? Hopefully someone can guide me.

    Read the article

  • Why does this Java code not utilize all CPU cores?

    - by ReneS
    The attached simple Java code should load all available cpu core when starting it with the right parameters. So for instance, you start it with java VMTest 8 int 0 and it will start 8 threads that do nothing else than looping and adding 2 to an integer. Something that runs in registers and not even allocates new memory. The problem we are facing now is, that we do not get a 24 core machine loaded (AMD 2 sockets with 12 cores each), when running this simple program (with 24 threads of course). Similar things happen with 2 programs each 12 threads or smaller machines. So our suspicion is that the JVM (Sun JDK 6u20 on Linux x64) does not scale well. Did anyone see similar things or has the ability to run it and report whether or not it runs well on his/her machine (= 8 cores only please)? Ideas? I tried that on Amazon EC2 with 8 cores too, but the virtual machine seems to run different from a real box, so the loading behaves totally strange. package com.test; import java.util.concurrent.ExecutorService; import java.util.concurrent.Executors; import java.util.concurrent.Future; import java.util.concurrent.TimeUnit; public class VMTest { public class IntTask implements Runnable { @Override public void run() { int i = 0; while (true) { i = i + 2; } } } public class StringTask implements Runnable { @Override public void run() { int i = 0; String s; while (true) { i++; s = "s" + Integer.valueOf(i); } } } public class ArrayTask implements Runnable { private final int size; public ArrayTask(int size) { this.size = size; } @Override public void run() { int i = 0; String[] s; while (true) { i++; s = new String[size]; } } } public void doIt(String[] args) throws InterruptedException { final String command = args[1].trim(); ExecutorService executor = Executors.newFixedThreadPool(Integer.valueOf(args[0])); for (int i = 0; i < Integer.valueOf(args[0]); i++) { Runnable runnable = null; if (command.equalsIgnoreCase("int")) { runnable = new IntTask(); } else if (command.equalsIgnoreCase("string")) { runnable = new StringTask(); } Future<?> submit = executor.submit(runnable); } executor.awaitTermination(1, TimeUnit.HOURS); } public static void main(String[] args) throws InterruptedException { if (args.length < 3) { System.err.println("Usage: VMTest threadCount taskDef size"); System.err.println("threadCount: Number 1..n"); System.err.println("taskDef: int string array"); System.err.println("size: size of memory allocation for array, "); System.exit(-1); } new VMTest().doIt(args); } }

    Read the article

  • SqlDataAdapter Update is not working in C# wih Sql Server

    - by Ahmed
    I am trying to save data from C# form to Sql server Northwind Orders database, I am only using CustomerID, OrderDate and ShippedDate for data entry. Following is the code to Form load and save button: private void Form1_Load(object sender, EventArgs e) { SetComb(); connectionString = ConfigurationManager.AppSettings["connectionString"]; sqlConnection = new SqlConnection(connectionString); String sqlSelect = "Select OrderID, CustomerID, OrderDate, ShippedDate from Orders"; sqlDataMaster = new SqlDataAdapter(sqlSelect, sqlConnection); sqlConnection.Open(); //=============================================================================== //--- Set up the INSERT Command //=============================================================================== sInsProcName = "prInsert_Order"; insertcommand = new SqlCommand(sInsProcName, sqlConnection); insertcommand.CommandType = CommandType.StoredProcedure; insertcommand.Parameters.Add(new SqlParameter("@nNewID", SqlDbType.Int, 0, ParameterDirection.Output, false, 0, 0, "OrderID", DataRowVersion.Default, null)); insertcommand.UpdatedRowSource = UpdateRowSource.OutputParameters; insertcommand.Parameters.Add(new SqlParameter("@sCustomerID", SqlDbType.NChar, 5,"CustomerID")); insertcommand.Parameters["@sCustomerID"].Value = cmbCust.SelectedValue; insertcommand.Parameters.Add(new SqlParameter("@dtOrderDate", SqlDbType.DateTime, 8,"OrderDate")); insertcommand.Parameters["@dtOrderDate"].Value = dtOrdDt.Text; insertcommand.Parameters.Add(new SqlParameter("@dtShipDate", SqlDbType.DateTime, 8,"ShippedDate")); insertcommand.Parameters["@dtShipDate"].Value = dtShipDt.Text; sqlDataMaster.InsertCommand = insertcommand; //=============================================================================== //--- Set up the UPDATE Command //=============================================================================== sUpdProcName = "prUpdate_Order"; updatecommand = new SqlCommand(sUpdProcName, sqlConnection); updatecommand.CommandType = CommandType.StoredProcedure; updatecommand.Parameters.Add(new SqlParameter("@nOrderID", SqlDbType.Int, 4, "OrderID")); updatecommand.Parameters.Add(new SqlParameter("@dtOrderDate", SqlDbType.DateTime, 8, "OrderDate")); updatecommand.Parameters.Add(new SqlParameter("@dtShipDate", SqlDbType.DateTime, 8, "ShippedDate")); sqlDataMaster.UpdateCommand = updatecommand; //=============================================================================== //--- Set up the DELETE Command //=============================================================================== sDelProcName = "prDelete_Order"; deletecommand = new SqlCommand(sDelProcName, sqlConnection); deletecommand.CommandType = CommandType.StoredProcedure; deletecommand.Parameters.Add(new SqlParameter("@nOrderID", SqlDbType.Int, 4, "OrderID")); sqlDataMaster.DeleteCommand = deletecommand; dt = new DataTable(); sqlDataMaster.FillSchema(dt, SchemaType.Source); ds = new DataSet(); ds.Tables.Add(dt); bs = new BindingSource(); bs.DataSource = ds.Tables[0]; } public void SetComb() { cmbCust.DataSource = dm.GetData("Select * from Customers order by CompanyName"); cmbCust.DisplayMember = "CompanyName"; cmbCust.ValueMember = "CustomerId"; cmbCust.Text = ""; } private void btnSave_Click(object sender, EventArgs e) { sqlDataMaster.Update((DataTable) bs.DataSource); } and Stored Procedures for Insert/Update/Delete set ANSI_NULLS ON set QUOTED_IDENTIFIER ON GO ALTER PROCEDURE [dbo].[prInsert_Order] -- ALTER PROCEDURE prInsert_Order @sCustomerID CHAR(5), @dtOrderDate DATETIME, @dtShipDate DATETIME, @nNewID INT OUTPUT AS SET NOCOUNT ON INSERT INTO Orders (CustomerID, OrderDate, ShippedDate) VALUES (@sCustomerID, @dtOrderDate, @dtShipDate) SELECT @nNewID = SCOPE_IDENTITY() set ANSI_NULLS ON set QUOTED_IDENTIFIER ON GO ALTER PROCEDURE [dbo].[prUpdate_Order] -- ALTER PROCEDURE prUpdate_Order @nOrderID INT, @dtOrderDate DATETIME, @dtShipDate DATETIME AS UPDATE Orders SET OrderDate = @dtOrderDate, ShippedDate = @dtShipDate WHERE OrderID = @nOrderID set ANSI_NULLS ON set QUOTED_IDENTIFIER ON GO ALTER PROCEDURE [dbo].[prDelete_Order] -- ALTER PROCEDURE prDelete_Order @nOrderID INT AS DELETE Orders WHERE OrderID = @nOrderID In the form CustomerID is selected via combobox which has Display property of CustomerName and Value property of CustomerID. But when clicking save button it shows no error, but it also don't save anything in Orders Table of Northwind....dm.GetData is the method of my Data Access Layer class to just get the info and populate CustomerID combobox. Any help with the code is highly appreciated... Thanks Ahmed

    Read the article

  • "FOR UPDATE" v/s "LOCK IN SHARE MODE" : Allow concurrent threads to read updated "state" value of locked row

    - by shadesco
    I have the following scenario: User X logs in to the application from location lc1: call it Ulc1 User X (has been hacked, or some friend of his knows his login credential, or he just logs in from a different browser on his machine,etc.. u got the point) logs in at the same time from location lc2: call it Ulc2 I am using a main servlet which : - gets a connection from database pooling - sets autocommit to false - executes a command that goes through app layers: if all successful, set autocommit to true in a "finally" statement, and closes connection. Else if an exception happens, rollback(). In my database (mysql/innoDb) i have a "history" table, with row columns: id(primary key) |username | date | topic | locked The column "locked" has by default value "false" and it serves as a flag that marks if a specific row is locked or not. Each row is specific to a user (as u can see from the username column) So back to the scenario: --Ulc1 sends the command to update his history from the db for date "D" and topic "T". --Ulc2 sends the same command to update history from the db for the same date "D" and same topic "T" at the exact same time. I want to implement an mysql/innoDB locking system that will enable whichever thread arriving to do the following check: Is column "locked" for this row true or not? if true, return a message to the user that " he is already updating the same data from another location" if not true (ie not locked) : flag it as locked and update then reset locked to false once finished. Which of these two mysql locking techniques, will actually allow the 2nd arriving thread from reading the "updated" value of the locked column to decide wt action to take?Should i use "FOR UPDATE" or "LOCK IN SHARE MODE"? This scenario explains what i want to accomplish: - Ulc1 thread arrives first: column "locked" is false, set it to true and continue updating process - Ulc2 thread arrives while Ulc1's transaction is still in process, and even though the row is locked through innoDb functionalities, it doesn't have to wait but in fact reads the "new" value of column locked which is "true", and so doesn't in fact have to wait till Ulc1 transaction commits to read the value of the "locked" column(anyway by that time the value of this column will already have been reset to false). I am not very experienced with the 2 types of locking mechanisms, what i understand so far is that LOCK IN SHARE MODE allow other transaction to read the locked row while FOR UPDATE doesn't even allow reading. But does this read gets on the updated value? or the 2nd arriving thread has to wait the first thread to commit to then read the value? Any recommendations about which locking mechanism to use for this scenario is appreciated. Also if there's a better way to "check" if the row has been locked (other than using a true/false column flag) please let me know about it. thank you SOLUTION (Jdbc pseudocode example based on @Darhazer's answer) Table : [ id(primary key) |username | date | topic | locked ] connection.setautocommit(false); //transaction-1 PreparedStatement ps1 = "Select locked from tableName for update where id="key" and locked=false); ps1.executeQuery(); //transaction 2 PreparedStatement ps2 = "Update tableName set locked=true where id="key"; ps2.executeUpdate(); connection.setautocommit(true);// here we allow other transactions threads to see the new value connection.setautocommit(false); //transaction 3 PreparedStatement ps3 = "Update tableName set aField="Sthg" where id="key" And date="D" and topic="T"; ps3.executeUpdate(); // reset locked to false PreparedStatement ps4 = "Update tableName set locked=false where id="key"; ps4.executeUpdate(); //commit connection.setautocommit(true);

    Read the article

  • "Undefined reference to"

    - by user1332364
    I know that there are a lot of questions somewhat related to this one, but they answers are a bit hard for me to make sense of. I'm receiving the following error for a few different lines of code: C:\Users\Jeff\AppData\Local\Temp\ccAixtmT.o:football.cpp:(.text+0x6f0): undefined reference to `Player::set_values(int, std::string, float)' From these blocks of code: class Player { int playerNum; string playerPos; float playerRank; public: void set_values(int, string, float); float get_rank(){ return playerRank; }; bool operator == (const Player &p1/*, const Player &p2*/) const { if(&p1.playerNum == &playerNum && &p1.playerPos == &playerPos && &p1.playerRank == &playerRank) return true; else return false; }; }; And this being the main function referencing the subclass: int main() { ifstream infile; infile.open ("input.txt", ifstream::in); int numTeams; string command; while(!infile.fail() && !infile.eof()){ infile >> numTeams; string name; Player p; int playNum; string playPos; float playRank; Player all[11]; float ranks[11]; Team allTeams[numTeams]; for(int i=0; i<numTeams; i++){ infile >> name; for(int j=0; j<11; j++){ infile >> playNum; infile >> playPos; infile >> playRank; if(playPos == "QB") p.set_values(playNum, playPos, (playRank*2.0)); else if(playPos == "RB") p.set_values(playNum, playPos, (playRank*1.5)); else if(playPos == "WR") p.set_values(playNum, playPos, (playRank/1.8)); else if(playPos == "TE") p.set_values(playNum, playPos, (playRank*1.1)); else if(playPos == "GD") p.set_values(playNum, playPos, (playRank/2.0)); else if(playPos == "TC") p.set_values(playNum, playPos, (playRank/2.2)); else if(playPos == "CR") p.set_values(playNum, playPos, (playRank/1.2)); all[j] = p; allTeams[i].set_values(all, name); } } infile >> command; if (command == "play"){ int t1; int t2; infile >> t1; infile >> t2; play(allTeams[t1], allTeams[t2]); } else { int t1; int p1; int t2; int p2; swap(allTeams[t1], allTeams[t1].get_player(p1), allTeams[t2], allTeams[t2].get_player(p2)); } } }

    Read the article

  • about getadrrinfo() C++?

    - by Isavel
    I'm reading this book called beej's guide to network programming and there's a part in the book were it provide a sample code which illustrate the use of getaddrinfo(); the book state that the code below "will print the IP addresses for whatever host you specify on the command line" - beej's guide to network programming. now I'm curious and want to try it out and run the code, but I guess the code was develop in UNIX environment and I'm using visual studio 2012 windows 7 OS, and most of the headers was not supported so I did a bit of research and find out that I need to include the winsock.h and ws2_32.lib for windows, for it to get working, fortunately everything compiled no errors, but when I run it using the debugger and put in 'www.google.com' as command argument I was disappointed that it did not print any ipaddress, the output that I got from the console is "getaddrinfo: E" what does the letter E mean? Do I need to configure something out of the debugger? Interestingly I left the command argument blank and the output changed to "usage: showip hostname" Any help would be appreciated. #ifdef _WIN32 #endif #include <sys/types.h> #include <winsock2.h> #include <ws2tcpip.h> #include <iostream> using namespace std; #include <stdio.h> #include <string.h> #include <sys/types.h> #include <winsock.h> #pragma comment(lib, "ws2_32.lib") int main(int argc, char *argv[]) { struct addrinfo hints, *res, *p; int status; char ipstr[INET6_ADDRSTRLEN]; if (argc != 2) { fprintf(stderr,"usage: showip hostname\n"); system("PAUSE"); return 1; } memset(&hints, 0, sizeof hints); hints.ai_family = AF_UNSPEC; // AF_INET or AF_INET6 to force version hints.ai_socktype = SOCK_STREAM; if ((status = getaddrinfo(argv[1], NULL, &hints, &res)) != 0) { fprintf(stderr, "getaddrinfo: %s\n", gai_strerror(status)); system("PAUSE"); return 2; } printf("IP addresses for %s:\n\n", argv[1]); for(p = res;p != NULL; p = p->ai_next) { void *addr; char *ipver; // get the pointer to the address itself, // different fields in IPv4 and IPv6: if (p->ai_family == AF_INET) { // IPv4 struct sockaddr_in *ipv4 = (struct sockaddr_in *)p->ai_addr; addr = &(ipv4->sin_addr); ipver = "IPv4"; } else { // IPv6 struct sockaddr_in6 *ipv6 = (struct sockaddr_in6 *)p->ai_addr; addr = &(ipv6->sin6_addr); ipver = "IPv6"; } // convert the IP to a string and print it: inet_ntop(p->ai_family, addr, ipstr, sizeof ipstr); printf(" %s: %s\n", ipver, ipstr); } freeaddrinfo(res); // free the linked list system("PAUSE"); return 0; }

    Read the article

  • MySQL Config File for Large System

    - by Jonathon
    We are running MySQL on a Windows 2003 Server Enterpise Edition box. MySQL is about the only program running on the box. We have approx. 8 slaves replicated to it, but my understanding is that having multiple slaves connecting to the same master does not significantly slow down performance, if at all. The master server has 16G RAM, 10 Terabyte drives in RAID 10, and four dual-core processors. From what I have seen from other sites, we have a really robust machine as our master db server. We just upgraded from a machine with only 4G RAM, but with similar hard drives, RAID, etc. It also ran Apache on it, so it was our db server and our application server. It was getting a little slow, so we split the db server onto this new machine and kept the application server on the first machine. We also distributed the application load amongst a few of our other slave servers, which also run the application. The problem is the new db server has mysqld.exe consuming 95-100% of CPU almost all the time and is really causing the app to run slowly. I know we have several queries and table structures that could be better optimized, but since they worked okay on the older, smaller server, I assume that our my.ini (MySQL config) file is not properly configured. Most of what I see on the net is for setting config files on small machines, so can anyone help me get the my.ini file correct for a large dedicated machine like ours? I just don't see how mysqld could get so bogged down! FYI: We have about 100 queries per second. We only use MyISAM tables, so skip-innodb is set in the ini file. And yes, I know it is reading the ini file correctly because I can change some settings (like the server-id and it will kill the server at startup). Here is the my.ini file: #MySQL Server Instance Configuration File # ---------------------------------------------------------------------- # Generated by the MySQL Server Instance Configuration Wizard # # # Installation Instructions # ---------------------------------------------------------------------- # # On Linux you can copy this file to /etc/my.cnf to set global options, # mysql-data-dir/my.cnf to set server-specific options # (@localstatedir@ for this installation) or to # ~/.my.cnf to set user-specific options. # # On Windows you should keep this file in the installation directory # of your server (e.g. C:\Program Files\MySQL\MySQL Server X.Y). To # make sure the server reads the config file use the startup option # "--defaults-file". # # To run run the server from the command line, execute this in a # command line shell, e.g. # mysqld --defaults-file="C:\Program Files\MySQL\MySQL Server X.Y\my.ini" # # To install the server as a Windows service manually, execute this in a # command line shell, e.g. # mysqld --install MySQLXY --defaults-file="C:\Program Files\MySQL\MySQL Server X.Y\my.ini" # # And then execute this in a command line shell to start the server, e.g. # net start MySQLXY # # # Guildlines for editing this file # ---------------------------------------------------------------------- # # In this file, you can use all long options that the program supports. # If you want to know the options a program supports, start the program # with the "--help" option. # # More detailed information about the individual options can also be # found in the manual. # # # CLIENT SECTION # ---------------------------------------------------------------------- # # The following options will be read by MySQL client applications. # Note that only client applications shipped by MySQL are guaranteed # to read this section. If you want your own MySQL client program to # honor these values, you need to specify it as an option during the # MySQL client library initialization. # [client] port=3306 [mysql] default-character-set=latin1 # SERVER SECTION # ---------------------------------------------------------------------- # # The following options will be read by the MySQL Server. Make sure that # you have installed the server correctly (see above) so it reads this # file. # [mysqld] # The TCP/IP Port the MySQL Server will listen on port=3306 #Path to installation directory. All paths are usually resolved relative to this. basedir="D:/MySQL/" #Path to the database root datadir="D:/MySQL/data" # The default character set that will be used when a new schema or table is # created and no character set is defined default-character-set=latin1 # The default storage engine that will be used when create new tables when default-storage-engine=MYISAM # Set the SQL mode to strict #sql-mode="STRICT_TRANS_TABLES,NO_AUTO_CREATE_USER,NO_ENGINE_SUBSTITUTION" # we changed this because there are a couple of queries that can get blocked otherwise sql-mode="" #performance configs skip-locking max_allowed_packet = 1M table_open_cache = 512 # The maximum amount of concurrent sessions the MySQL server will # allow. One of these connections will be reserved for a user with # SUPER privileges to allow the administrator to login even if the # connection limit has been reached. max_connections=1510 # Query cache is used to cache SELECT results and later return them # without actual executing the same query once again. Having the query # cache enabled may result in significant speed improvements, if your # have a lot of identical queries and rarely changing tables. See the # "Qcache_lowmem_prunes" status variable to check if the current value # is high enough for your load. # Note: In case your tables change very often or if your queries are # textually different every time, the query cache may result in a # slowdown instead of a performance improvement. query_cache_size=168M # The number of open tables for all threads. Increasing this value # increases the number of file descriptors that mysqld requires. # Therefore you have to make sure to set the amount of open files # allowed to at least 4096 in the variable "open-files-limit" in # section [mysqld_safe] table_cache=3020 # Maximum size for internal (in-memory) temporary tables. If a table # grows larger than this value, it is automatically converted to disk # based table This limitation is for a single table. There can be many # of them. tmp_table_size=30M # How many threads we should keep in a cache for reuse. When a client # disconnects, the client's threads are put in the cache if there aren't # more than thread_cache_size threads from before. This greatly reduces # the amount of thread creations needed if you have a lot of new # connections. (Normally this doesn't give a notable performance # improvement if you have a good thread implementation.) thread_cache_size=64 #*** MyISAM Specific options # The maximum size of the temporary file MySQL is allowed to use while # recreating the index (during REPAIR, ALTER TABLE or LOAD DATA INFILE. # If the file-size would be bigger than this, the index will be created # through the key cache (which is slower). myisam_max_sort_file_size=100G # If the temporary file used for fast index creation would be bigger # than using the key cache by the amount specified here, then prefer the # key cache method. This is mainly used to force long character keys in # large tables to use the slower key cache method to create the index. myisam_sort_buffer_size=64M # Size of the Key Buffer, used to cache index blocks for MyISAM tables. # Do not set it larger than 30% of your available memory, as some memory # is also required by the OS to cache rows. Even if you're not using # MyISAM tables, you should still set it to 8-64M as it will also be # used for internal temporary disk tables. key_buffer_size=3072M # Size of the buffer used for doing full table scans of MyISAM tables. # Allocated per thread, if a full scan is needed. read_buffer_size=2M read_rnd_buffer_size=8M # This buffer is allocated when MySQL needs to rebuild the index in # REPAIR, OPTIMZE, ALTER table statements as well as in LOAD DATA INFILE # into an empty table. It is allocated per thread so be careful with # large settings. sort_buffer_size=2M #*** INNODB Specific options *** innodb_data_home_dir="D:/MySQL InnoDB Datafiles/" # Use this option if you have a MySQL server with InnoDB support enabled # but you do not plan to use it. This will save memory and disk space # and speed up some things. skip-innodb # Additional memory pool that is used by InnoDB to store metadata # information. If InnoDB requires more memory for this purpose it will # start to allocate it from the OS. As this is fast enough on most # recent operating systems, you normally do not need to change this # value. SHOW INNODB STATUS will display the current amount used. innodb_additional_mem_pool_size=11M # If set to 1, InnoDB will flush (fsync) the transaction logs to the # disk at each commit, which offers full ACID behavior. If you are # willing to compromise this safety, and you are running small # transactions, you may set this to 0 or 2 to reduce disk I/O to the # logs. Value 0 means that the log is only written to the log file and # the log file flushed to disk approximately once per second. Value 2 # means the log is written to the log file at each commit, but the log # file is only flushed to disk approximately once per second. innodb_flush_log_at_trx_commit=1 # The size of the buffer InnoDB uses for buffering log data. As soon as # it is full, InnoDB will have to flush it to disk. As it is flushed # once per second anyway, it does not make sense to have it very large # (even with long transactions). innodb_log_buffer_size=6M # InnoDB, unlike MyISAM, uses a buffer pool to cache both indexes and # row data. The bigger you set this the less disk I/O is needed to # access data in tables. On a dedicated database server you may set this # parameter up to 80% of the machine physical memory size. Do not set it # too large, though, because competition of the physical memory may # cause paging in the operating system. Note that on 32bit systems you # might be limited to 2-3.5G of user level memory per process, so do not # set it too high. innodb_buffer_pool_size=500M # Size of each log file in a log group. You should set the combined size # of log files to about 25%-100% of your buffer pool size to avoid # unneeded buffer pool flush activity on log file overwrite. However, # note that a larger logfile size will increase the time needed for the # recovery process. innodb_log_file_size=100M # Number of threads allowed inside the InnoDB kernel. The optimal value # depends highly on the application, hardware as well as the OS # scheduler properties. A too high value may lead to thread thrashing. innodb_thread_concurrency=10 #replication settings (this is the master) log-bin=log server-id = 1 Thanks for all the help. It is greatly appreciated.

    Read the article

  • find substring and indices in mips

    - by ccc
    im trying find out substring and first occurrence indices. but something wrong. im comparing each element of pattern array and each element of string array until pointer reach to '\0'. and if any characater found it keep in temp array. and increasing pointers +1. whats the problem. algorithm is totaly wrong ? #Note: $v0 is a symbolic name used by the assember for $2. # $a0 is a symbolic name used by the assember for $4. .data prompt_str: .asciiz "Please type a text string: " prompt_ptr: .asciiz "Please type a pattern string: " print_yes: .asciiz "Yes, there is a match." print_no: .asciiz "No, there is no match." text_str: .asciiz "Text string : " pattern_str: .asciiz "Pattern string : " print_out: .asciiz "Output to be produced :" print_dash: .asciiz "----------------------" print_index: .asciiz "Starting index :" print_msg : .asciiz "Length of longest partial match = " nl: .asciiz "\n" str : .space 81 ptr : .space 81 tmp : .space 81 .text main: la $a0, prompt_str li $v0, 4 #print_string command. syscall la $a0,str #read string li $a1,81 li $v0,8 syscall la $t0,str #move string to $t0 la $a0,prompt_ptr li $v0,4 #print pattern command syscall la $a0,ptr #read pattern li $a1,81 li $v0,8 syscall la $t1,ptr #move pattern to $t1 la $t5,tmp #move temp to $t5 lb $t2,0($t0) #pointer first element array of string lb $t3,0($t1) #pointer first element array of pattern lb $t6,0($t5) #pointer first element array of temp loop : beq $t3,$0,end_loop beq $t2,$t3,match addiu $t0,$t0,1 j loop match : move $t6,$t2 addiu $t5,$t5,1 addiu $t0,$t0,1 addiu $t1,$t1,1 j print_match print_match : la $a0,text_str #print string li $v0,4 syscall move $a0,$t0 li $v0,4 syscall la $a0,nl #print newline character li $v0,4 syscall la $a0,pattern_str #print pattern string li $v0,4 syscall move $a0,$t1 li $v0,4 syscall la $a0,nl #print newline character li $v0,4 syscall la $a0,print_out #print output line and newline character li $v0,4 syscall la $a0,nl li $v0,4 syscall la $a0,print_dash li $v0,4 syscall la $a0,print_yes li $v0,4 syscall la $a0,print_index #print starting index li $v0,4 syscall li $v0,10 syscall end_loop : li $v0,10 syscall

    Read the article

  • MSBuild (.NET 4.0) access problems

    - by JMP
    I'm using Cruise Control .NET as my build server (Windows 2008 Server). Yesterday I upgraded my ASP.NET MVC project from VS 2008/.NET 3.5 to VS 2010/.NET 4.0. The only change I made to my ccnet.config's MSBuild task was the location of MSBuild.exe. Ever since I made that change, the build has been broken with the error: MSB4019 - The imported project "C:\Program Files (x86)\MSBuild\Microsoft\VisualStudio\v10.0\WebApplications\Microsoft.WebApplication.targets" was not found. Confirm that the path in the declaration is correct, and that the file exists on disk. This file does, in fact, exist in the location specified (I solved a problem similar to this when setting up the build server for VS2008/.NET 3.5 by copying the files from my dev environment to my build environment). So I RDP'ed into the build machine and opened a command prompt, used MSBUILD to attempt to build my project. MSBUILD returns the error: MSB3021 - Unable to copy file "obj\debug....dll". Access to the path 'bin....dll' is denied. Since I'm running MSBUILD from the command prompt, logged in with an account that has administrative privileges, I'm assuming that MSBUILD is running with the same privileges that I have. Next, I tried to copy the file that MSBUILD was attempting to copy. In this case, I get the UAC dialog that makes me click the [Continue] button to complete the copy. I'd like to avoid installing Visual Studio 2010 on my build machine, can anyone suggest other fixes I might try?

    Read the article

  • i get the exception org.hibernate.MappingException: No Dialect mapping for JDBC type: -9

    - by ramesh m
    i am using hibernate .i wrote Native sql query. this query will be execute in sqlSever command promt try { session=HibernateUtil.getInstance().getSession(); transaction=session.beginTransaction(); SQLQuery query = session.createSQLQuery("SELECT AP.PROJECT_NAME, AP.SKILLSET, PA.START_DATE, PA.END_DATE, RS.EMPLOYEE_ID, RS.EMPLOYEE_NAME, RS.REPORTING_PM FROM RESOURCE_MASTER RS,SHARED_PROPOSAL S, ACTUAL_PROPOSAL AP, PROJECT_APPROVED PA, PROJECT_ALLOCATION PL WHERE RS.EMPLOYEE_ID = PL.EMPLOYEE_ID AND PA.PROJECT_ID = PL.PROJECT_ID AND PA.SHARED_PROPOSAL_ID = S.SHARED_PROPOSAL_ID AND S.ACTUAL_PROPOSAL_ID=AP.ACTUAL_PROPOSAL_ID"); List<Object[]> obj=query.list(); Object[] object=new Object[arrayList.size()]; for (int i = 0; i < arrayList.size(); i++) { object[i]=arrayList.get(i); System.out.println(object[i]); } arrayList.get(0); String name=(String)arrayList.get(0); logger.info("In find All searchDeveloper"); }catch(Exception exception) { throw new PPAMException("Contact admin","Problem retrieving resource master list",exception); } like that i am using on that time i got this Exception: org.hibernate.MappingException: No Dialect mapping for JDBC type: -9 this query is executed in sqlserver command propt , i maaped seven tables, but remove ACTUAL_PROPOSAL AP table .it is execute correctly please help me

    Read the article

  • Could not start ZK at requested port of 2181, while export HBASE_MANAGES_ZK=false

    - by utrecht
    Problem The first aim was to run HBase standalone. Navigating to ip:60010/master-status is succesfull once HBase has been started. The second aim is to run a distinct ZooKeeper quorum. ZooKeeper has been downloaded and has been started: netstat -nato | grep 2181 tcp 0 0 :::2181 :::* LISTEN off (0.00/0/0) The conf/hbase-env.sh was changed as follows: # Tell HBase whether it should manage it's own instance of Zookeeper or not. export HBASE_MANAGES_ZK=false in order to avoid HBase starts ZooKeeper once HBase has been started. However, the following error occurs once HBase has been started. Could not start ZK at requested port of 2181. ZK was started at port: 2182. Aborting as clients (e.g. shell) will not be able to find this ZK quorum. Question How to disable the startup of ZooKeeper by HBase and run ZooKeeper separately?

    Read the article

  • Why do I see "Operation was denied because the current credentials do not have the appropriate privileges" when trying to chsh?

    - by alecmce
    I'm setting up a new dev Macbook Pro, and trying to replace bash with zsh. I installed zsh and can run it to change shell in a session. When I use sudo chsh -s /bin/zsh username I get the error message: chsh: Operation was denied because the current credentials do not have the appropriate privileges. Operation was denied because the current credentials do not have the appropriate privileges. AFAIK I have admin privileges on the machine. What could be causing this?

    Read the article

  • File system loop detected in /var/named/chroot/var/named/ CentOS6.3

    - by wilco
    When I use find command on shell, I got the following error. find: File system loop detected; /var/named/chroot/var/named' is part of the same file system loop as/var/named'. I verified the inode number and it comes out the same as below. [root@serverone ~]# ls -ldi /var/named/chroot/var/named/ /var/named 6684673 drwxr-x--- 6 root named 4096 Sep 7 17:17 /var/named 6684673 drwxr-x--- 6 root named 4096 Sep 7 17:17 /var/named/chroot/var/named/ I cannot remove the directory with rm -f and it is saying this is directory. It is minimal CentOS6.3 install with plesk 11. Any help would be appreciated.

    Read the article

  • "SignTool error: Access is denied" in TFS 2010 build process

    - by user351352
    I'm getting "SignTool Error: Access is Denied" when I attempt to sign a file. When I use an administrator cmd, all works fine. However, this process is going to be used in a TFS 2010 build process and using the InvokeProcess task with signtool gives the same access denied message as a non-administrator command prompt. More info: On a Win2008 R2 enterprise machine. User is machine admin and on the domain. The TFS Build service is also set to run as this user. Using a self signed certificate created using these instructions: How do I create a self-signed certificate for code signing on Windows? After following these instructions I have the following files: MyCA.cer MyCA.pvk MySPC.cer MySPC.pvk MySPC.pfx MyCA is in my Trusted Root Certification Authorities I imported MySPC.pfx into personal certificates, following the advice here: SignTool error: Access is denied To do the signing I'm using the thumbprint of the MySPC.pfx that was imported into the Personal section so my signtool command looks like: sign /sha1 1e9d7b5ad98552d9c58944e3f3903e6b929f4819 /t http://timestamp.verisign.com/scripts/timestamp.dll "FileName" Once again this works in Admin mode. This also works when running cmd as administrator: sign /f "C:\Code Signing Non-Release\MySPC.pfx" /t http://timestamp.verisign.com/scripts/timestamp.dll "FileName" New to code signing in general, so any help is welcome.

    Read the article

  • using ILMerge with .NET 4 libraries

    - by Sarah Vessels
    I'm having trouble using ILMerge in my post-build after upgrading from .NET 3.5/Visual Studio 2008 to .NET 4/Visual Studio 2010. I have a Solution with several projects whose target framework is set to ".NET Framework 4". I use the following ILMerge command to merge the individual project DLLs into a single DLL: if not $(ConfigurationName) == Debug if exist "C:\Program Files (x86)\Microsoft\ILMerge\ILMerge.exe" "C:\Program Files (x86)\Microsoft\ILMerge\ILMerge.exe" /lib:"C:\Windows\Microsoft.NET\Framework64\v4.0.30319" /lib:"C:\Program Files (x86)\Microsoft Visual Studio 10.0\Common7\IDE\PublicAssemblies" /keyfile:"$(SolutionDir)$(SolutionName).snk" /targetplatform:v4 /out:"$(SolutionDir)bin\development\$(SolutionName).dll" "$(SolutionDir)Connection\$(OutDir)Connection.dll" ...other project DLLs... /xmldocs If I leave off specifying the location of the .NET 4 framework directory, I get an "Unresolved assembly reference not allowed: System" error from ILMerge. If I leave off specifying the location of the MSTest directory, I get an "Unresolved assembly reference not allowed: Microsoft.VisualStudio.QualityTools.UnitTestFramework" error. The ILMerge command above works and produces a DLL. When I reference that DLL in another .NET 4 C# project, however, and try to use code within it, I get the following warning: The primary reference "MyILMergedDLL" could not be resolved because it has an indirect dependency on the .NET Framework assembly "mscorlib, Version=4.0, Culture=neutral, PublicKeyToken=b77a5c561934e089" which has a higher version "4.0.65535.65535" than the version "4.0.0.0" in the current target framework. If I then remove the /targetplatform:v4 flag and try to use MyILMergedDLL.dll, I get the following error: The type 'System.Xml.Serialization.IXmlSerializable' is defined in an assembly that is not referenced. You must add a reference to assembly 'System.Xml, Version=4.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089'. It doesn't seem like I should have to do that. Whoever uses my MyILMergedDLL.dll API should not have to add references to whatever libraries it references. How can I get around this?

    Read the article

  • Creating a multi-tenant application using PostgreSQL's schemas and Rails

    - by ramon.tayag
    Stuff I've already figured out I'm learning how to create a multi-tenant application in Rails that serves data from different schemas based on what domain or subdomain is used to view the application. I already have a few concerns answered: How can you get subdomain-fu to work with domains as well? Here's someone that asked the same question which leads you to this blog. What database, and how will it be structured? Here's an excellent talk by Guy Naor, and good question about PostgreSQL and schemas. I already know my schemas will all have the same structure. They will differ in the data they hold. So, how can you run migrations for all schemas? Here's an answer. Those three points cover a lot of the general stuff I need to know. However, in the next steps I seem to have many ways of implementing things. I'm hoping that there's a better, easier way. Finally, to my question When a new user signs up, I can easily create the schema. However, what would be the best and easiest way to load the structure that the rest of the schemas already have? Here are some questions/scenarios that might give you a better idea. Should I pass it on to a shell script that dumps the public schema into a temporary one, and imports it back to my main database (pretty much like what Guy Naor says in his video)? Here's a quick summary/script I got from the helpful #postgres on freenode. While this will probably work, I'm gonna have to do a lot of stuff outside of Rails, which makes me a bit uncomfortable.. which also brings me to the next question. Is there a way to do this straight from Ruby on Rails? Like create a PostgreSQL schema, then just load the Rails database schema (schema.rb - I know, it's confusing) into that PostgreSQL schema. Is there a gem/plugin that has these things already? Methods like "create_pg_schema_and_load_rails_schema(the_new_schema_name)". If there's none, I'll probably work at making one, but I'm doubtful about how well tested it'll be with all the moving parts (especially if I end up using a shell script to create and manage new PostgreSQL schemas). Thanks, and I hope that wasn't too long! UPDATE May 11, 2010 11:26 GMT+8 Since last night I've been able to get a method to work that creates a new schema and loads schema.rb into it. Not sure if what I'm doing is correct (seems to work fine, so far) but it's a step closer at least. If there's a better way please let me know. module SchemaUtils def self.add_schema_to_path(schema) conn = ActiveRecord::Base.connection conn.execute "SET search_path TO #{schema}, #{conn.schema_search_path}" end def self.reset_search_path conn = ActiveRecord::Base.connection conn.execute "SET search_path TO #{conn.schema_search_path}" end def self.create_and_migrate_schema(schema_name) conn = ActiveRecord::Base.connection schemas = conn.select_values("select * from pg_namespace where nspname != 'information_schema' AND nspname NOT LIKE 'pg%'") if schemas.include?(schema_name) tables = conn.tables Rails.logger.info "#{schema_name} exists already with these tables #{tables.inspect}" else Rails.logger.info "About to create #{schema_name}" conn.execute "create schema #{schema_name}" end # Save the old search path so we can set it back at the end of this method old_search_path = conn.schema_search_path # Tried to set the search path like in the methods above (from Guy Naor) # conn.execute "SET search_path TO #{schema_name}" # But the connection itself seems to remember the old search path. # If set this way, it works. conn.schema_search_path = schema_name # Directly from databases.rake. # In Rails 2.3.5 databases.rake can be found in railties/lib/tasks/databases.rake file = "#{Rails.root}/db/schema.rb" if File.exists?(file) Rails.logger.info "About to load the schema #{file}" load(file) else abort %{#{file} doesn't exist yet. It's possible that you just ran a migration!} end Rails.logger.info "About to set search path back to #{old_search_path}." conn.schema_search_path = old_search_path end end

    Read the article

  • Random DNS Client Issue with BIND9/Windows Server 2003 DNS

    - by upkels
    Within our office, we have a local server running DNS, for internal related "domains", (e.g. .internal, .office, .lan, .vpn, etc.). Randomly, only the hosts configured with those extensions will stop resolving on the Windows-based workstations. Sometimes it'll work for a couple weeks without issue on one machine, then suddenly stop working, or it'll happen on another 15 times per day. It's completely random for all workstations. When troubleshooting, I have opened up a command prompt, and issued various nslookup commands for some of these hosts, and they resolve, however I've been told that nslookup uses different "libraries" for name resolution than other applications such as web browsers, email clients, etc. The only solution thus far, is manually restarting the Windows DNS Client on each workstation when this happens. Issuing the ipconfig /flushdns command multiple times helps every now and then, but is not successful enough to even attempt before restarting the DNS Client. I have tried two different DNS servers; BIND9, and Windows Server 2003 R2 DNS, and the behavior is the same. We have a single Netgear JGS524 switch all workstations and servers are connected to within the office, and a Linksys SR224G switch in another department with workstations attached.

    Read the article

  • Entity Framework with MySQL - Timeout Expired while Generating Model

    - by Nathan Taylor
    I've constructed a database in MySQL and I am attempting to map it out with Entity Framework, but I start running into "GenerateSSDLException"s whenever I try to add more than about 20 tables to the EF context. An exception of type 'Microsoft.Data.Entity.Design.VisualStudio.ModelWizard.Engine.ModelBuilderEngine+GenerateSSDLException' occurred while attempting to update from the database. The exception message is: 'An error occurred while executing the command definition. See the inner exception for details.' Fatal error encountered during command execution. Timeout expired. The timeout period elapsed prior to completion of the operation or the server is not responding. There's nothing special about the affected tables, and it's never the same table(s), it's just that after a certain (unspecific) number of tables have been added, the context can no longer be updated without the "Timeout expired" error. Sometimes it's only one table left over, and sometimes it's three; results are pretty unpredictable. Furthermore, the variance in the number of tables which can be added before the error indicates to me that perhaps the problem lies in the size of the query being generated to update the context which includes both the existing table definitions, and also the new tables that are being added to it. Essentially, the SQL query is getting too large and it's failing to execute for some reason. If I generate the model with EdmGen2 it works without any errors, but the generated EDMX file cannot be updated within Visual Studio without producing the aforementioned exception. In all likelihood the source of this problem lies in the tool within Visual Studio given that EdmGen2 works fine, but I'm hoping that perhaps others could offer some advice on how to approach this very unique issue, because it seems like I'm not the only person experiencing it. One suggestion a colleague offered was maintaining two separate EBMX files with some table crossover, but that seems like a pretty ugly fix in my opinion. I suppose this is what I get for trying to use "new technology". :(

    Read the article