Search Results

Search found 39406 results on 1577 pages for 'two legged'.

Page 455/1577 | < Previous Page | 451 452 453 454 455 456 457 458 459 460 461 462  | Next Page >

  • Multihomed Windows server and DNS resolution

    - by mpkilroy
    I have a Windows 2008 server with two IP addresses assigned to a single NIC. The DNS settings are setup to register the connections's addresses on the DNS server. nslookup shows both IP addresses for the server name. How is name resolution done in this case, i.e. which IP address does the DNS server return for a host lookup? Or does it return both, and the client selects one of the addresses?

    Read the article

  • What exactly is the difference between update-manager -d and the process

    - by jldugger
    The official recommendation of Ubuntu is to use sudo do-release-upgrade to do an online upgrade from one version to the next. Historically many of my Debianite friends and myself have simply altered apt's sources.list and run apt-get dist-upgrade. I follow Ubuntu's recommendations, but I've always wondered what the magic difference between these two processes is. What, exactly, does do-release-upgrade do, on say an upgrade from 9.04 to 9.10? (Examples from other releases welcome.)

    Read the article

  • How long does a blocked connection from Iptables last? Is there a way to set the timeout?

    - by Josh
    iptables -A INPUT -m state --state NEW -m recent --set # If we receive more than 10 connections in 10 seconds block our friend. iptables -A INPUT -m state --state NEW -m recent --update --seconds 5 --hitcount 15 -j Log-N-Drop I have these two relevant rules from iptables. if more than 15 connections are made in 5 seconds it logs the attempt and blocks it. How long does iptables maintain the counter? Does it refresh if connections are attempted again?

    Read the article

  • Selectively Remove Auto Complete Entries from Internet Explorer

    - by Kanini
    Hello...I use Windows XP with IE 8. When I try to access GMail (or any other site for that matter), the Auto Complete feature shows the list of username and on select of that, it auto-completes the password as well. Is there a way, I can selectively remove one or two of the entries alone without having to delete all of Auto Complete entries? PS: Ofcourse, I do know about In-Private browsing and that it can be used for ensuring that a History is not left behind and ...

    Read the article

  • Why do my files fail checksums when transferring to esata dive but not when transfered off the external?

    - by R. Peterson
    I have been using teracopy to verify and the large movie files show artifacting after transfer and fail checksum, small files do not fail, only large files seem to. When I transfer files off the external hard drive no such failure of checksums occur on any of the files, could this be a bad cable, or maybe a bad external interface or esata interface on my computer, I have tried two interfaces for esata, one with a pci card the other on the motherboard, both with similar results, so what maybe the reason if a bad hard drive or external case maybe the problem?

    Read the article

  • Import into Aperture 3 without moving files

    - by delwin
    I like managing my own files, and this is definitely possible with Aperture 3. But there seems to be two ways to import into Aperture: either by dragging and dropping, or importing one folder at a time, manually, through the Aperture import window. BUT whenever I drag and drop the photos, it imports them into the Aperture library, making duplicates of everything. And if I add them manually through Aperture, I have to add each folder at a time, which is extremely tedious. Is there any solution?

    Read the article

  • networking related problem

    - by abhay
    i have installed two LAN cards in my PC. one is used for local networking and other is for Wide area networking( both have a different gateways). But when i need to browse in WAN for that i have to disable my LAN and vice versa. so i don't know the technical / logical reason behind that. so could you please give me reason why this happens.

    Read the article

  • Comparison between operational systems

    - by Gustavo Bandeira
    Some years ago, I've heard people saying that the OSX and Linux were better than Windows, I also remember of reading something that said the Solaris operating system didn't fragment their files and that the Linux file system was almost in the same step but none of these claims seemed to have basis or references. I got two questions: When comparing operating systems, what are the main points for comparison? How's the comparison between the main operating systems today?

    Read the article

  • Perl program doesn't get displayed in browser (windows)

    - by Dextar
    system info: i have installed XAMPP on my machine having Window XP OS . also installed Apache2.2, now, i have created two folders in C:\xampp\htdocs they are php and perl . these folder contains programs in their respective languages (ie index.php and index.pl respectively) when i type in browser : http: //localhost:88/php/ the program in index.php gets executed and o/p is displayed in browser but , when i type: http://localhost:88/perl/ browser displays a blank page PROBLEM : how to run .pl file in above scenario ?

    Read the article

  • Can a faulty battery cause a laptop to crash?

    - by Paul Johnson
    After replacing a blown out motherboard, my Toshiba Satellite C600 is still malfunctioning lately: BSODs. Distorted graphics, and freezes. Sudden shutdowns. After removing the battery and doing a re-format the laptop works perfectly (I should mention the problems continued before removing the battery after the re-format). I haven't seen a fault while solely running on A/C power for two days. Could the problem be a faulty battery?

    Read the article

  • RSH between servers not working

    - by churnd
    I have two servers: one CentOS 5.8 & one Solaris 10. Both are joined to my workplace AD domain via PBIS-Open. A user will log into the linux server & run an application which issues commands over RSH to the solaris server. Some commands are also run on the linux server, so both are needed. Due to the application these servers are being used for (proprietary GE software), the software on the linux server needs to be able to issue rsh commands to the solaris server on behalf of the user (the user just runs a script & the rest is automatic). However, rsh is not working for the domain users. It does work for a local user, so I believe I have the necessary trust settings between the two servers correct. However, I can rlogin as a domain user from the linux server to the solaris server. SSH works too (how I wish I could use it). Some relevant info: via rlogin: [user@linux~]$ rlogin solaris connect to address 192.168.1.2 port 543: Connection refused Trying krb4 rlogin... connect to address 192.168.1.2 port 543: Connection refused trying normal rlogin (/usr/bin/rlogin) Sun Microsystems Inc. SunOS 5.10 Generic January 2005 solaris% via rsh: [user@linux ~]$ rsh solaris ls connect to address 192.168.1.2 port 544: Connection refused Trying krb4 rsh... connect to address 192.168.1.2 port 544: Connection refused trying normal rsh (/usr/bin/rsh) permission denied. [user@linux ~]$ relevant snippet from /etc/pam.conf on solaris: # # rlogin service (explicit because of pam_rhost_auth) # rlogin auth sufficient pam_rhosts_auth.so.1 rlogin auth requisite pam_lsass.so set_default_repository rlogin auth requisite pam_lsass.so smartcard_prompt try_first_pass rlogin auth requisite pam_authtok_get.so.1 try_first_pass rlogin auth sufficient pam_lsass.so try_first_pass rlogin auth required pam_dhkeys.so.1 rlogin auth required pam_unix_cred.so.1 rlogin auth required pam_unix_auth.so.1 # # Kerberized rlogin service # krlogin auth required pam_unix_cred.so.1 krlogin auth required pam_krb5.so.1 # # rsh service (explicit because of pam_rhost_auth, # and pam_unix_auth for meaningful pam_setcred) # rsh auth sufficient pam_rhosts_auth.so.1 rsh auth required pam_unix_cred.so.1 # # Kerberized rsh service # krsh auth required pam_unix_cred.so.1 krsh auth required pam_krb5.so.1 # I have not really seen anything useful in either system log that seem to be directly related to the failed login attempt. I've tail -f'd /var/adm/messages on solaris & /var/log/messages on linux during the failed attempts & nothing shows up. Maybe I need to be doing something else?

    Read the article

  • Can you tell DDR and DDR2 apart visually?

    - by Macha
    I'm getting a few old computers to take apart for parts soon. Most of them are defintely using DDR2 RAM, but there is the possibility that one or two of them are using DDR RAM. Since these are quite old, the manuals have since been lost. Is it possible to tell DDR and DDR2 RAM apart visually, and if so how?

    Read the article

  • Combine lighttpd configs for IPv4 and IPv6

    - by mrothe
    My lighttpd.conf includes the following lines: $SERVER["socket"] == "188.40.236.66:443" { ssl.engine = "enable" ssl.ca-file = "/etc/lighttpd/ssl/startcom.ca.pem" ssl.pemfile = "/etc/lighttpd/ssl/www.unixforces.net.pem" } $SERVER["socket"] == "[2a01:4f8:100:30a5:0:bc28:ec43:2]:443" { ssl.engine = "enable" ssl.ca-file = "/etc/lighttpd/ssl/startcom.ca.pem" ssl.pemfile = "/etc/lighttpd/ssl/www.unixforces.net.pem" } Is it possible to combine these two blocks into one? $SERVER["socket"] only allows for == and not =~.

    Read the article

  • Capturing same interface with tshark with same or different capture filters

    - by Pankaj Goyal
    I am in stuck in a situation where an interface will be captured more than one time. Like :- $ tshark -i rpcap://1.1.1.1/lo -f "ip proto 1" -i rpcap://1.1.1.1/lo -f "ip proto 132" or (same filter) $ tshark -i rpcap://1.1.1.1/lo -f "ip proto 1" -i rpcap://1.1.1.1/lo -f "ip proto 1" what will happen in both the cases ? In first case, will the capture filter gets OR'ed or AND'ed ?? In second case, will the same packets be captured two times ?

    Read the article

  • Intermittently, IIS7 requests get stuck in WindowsAuthenticationModule

    - by Richard Beier
    We're running an IIS7 server hosting several dozen websites. Several of these websites are all part of the same legacy app we've developed. These sites all run the same code and run in the same app pool. Roughly once a month over the past few months, we've found that all requests for this app pool start hanging indefinitely. When this happens, we receive an alert and we recycle the app pool. After that, the sites start working again. This only ever affects this one app pool - never any others on the same server. A couple times, before recycling the pool, I've looked at the currently-executing requests in the worker process. They all show up as executing inside the WindowsAuthenticationModule. Which is strange, because the vast majority of the application does not require authentication. There is a small admin section which uses Windows auth... but all the other requests should be anonymous. Does anyone have any idea as to what might be causing this? There are several unusual things about the way these sites are set up. As I mentioned, they all run the same code - multiple sites point at the same physical directory. The only difference is the host header bindings. I'm not sure why there isn't just one site with all the host headers, but that's how it works. In several of these sites, the same physical directory is mapped at two levels - as the root of the site and again as an application within the site. So if a user goes to http://oursite.com/index.aspx, that maps to c:\files\oursite\index.aspx. If a user goes to http://oursite.com/foo/index.aspx, that also maps to c:\files\oursite\index.aspx. I think there is code which looks at the request URL and handles the two requests differently. This is strange because the same web.config ends up being interpreted as a site config file, and also as an application config file within the site. I don't know if this might be related to the authentication problem. If we can't find the cause, we're thinking of a few workarounds we could try: Move the admin section into a separate site, and give the client a new admin URL. Run that separate site in its own app pool. Then in the web.config shared by all the other sites, remove the WindowsAuthenticationModule. That way there should be no possibility of a hang within the WindowsAuthenticationModule. Try running all these sites in the classic pipeline instead of the integrated pipeline. They were working fine on our old IIS6 server... (If we get desperate) Set up a watchdog script which monitors the sites and auto-recycles the app pool when it detects that requests are getting stuck. What do you think? Thanks for your help, Richard

    Read the article

  • Configuration Manager sub site codes

    - by NA Slacker
    I have two sub-sites set up in configuration manager. When the SCCM agent installs on the client machines within the boundaries of those sub sites they are assigned the site code of the Primary site, not the sub site code. As a result their management server remains the main server not the sub site server. I am setting up thes sub sites on cross WAN locations to cut down on traffic. What could be preventing the clients from getting associated with the proper sub site code.

    Read the article

  • How long are fragmented TCP fragments kept in the TCP server

    - by Justin
    Suppose that a given TCP fragment is fragmented into two IP datagrams, and that the first datagram arrives to the TCP server, but the second datagram never arrives. After a certain amount of time the TCP server sends a keepalive, and determines that the client is alive. What does the TCP server then do with this first datagram? Does is wait for the second datagram to arrive, or does it discard the first datagram?

    Read the article

  • Excel 2007 Macro Changes?

    - by Guy Thomas
    My excel macros are no longer working as designed. Last week they worked as expected, this week a different result. I even tried a two year old version, it did not work the way it used to. Guy's conclusion an Office / Excel update changed the macro behaviour. Am I alone in this conclusion? If so I'll take a different troubleshooting approach.

    Read the article

  • HP UX can not boot from Ignite Tape

    - by Spirit
    We have hp rp2470 server running hp-ux 11.00, with LVM mirroring. As for redundancy we have second rp2470 same hw (same two processors, same ram, same two hdd’s, same number of lan cards). I want to clone first one to the second. For that purpose I am making ignite tape with the following command: make_tape_recovery -x inc_entire=vg00 Ignite tape finishes without problems. When I boot second server from this ignate tape, server is starting to boot, and ignite restore finishes without any errors, only few notes, which are normal. However vmunix is not booting and when restore finishes, it boot to ISL prompt. From this I cannot boot /stand/vmunix. I tried to run recovery shell but no success. When recovery shell ask to do frecover to restore critical files, then I receive error: frecover(5405): unable to open /dev/rmt/0m At first I thought that the problem might be in the difference of the firmware version of the servers: fw version of production server is: Firmware Version 43.50 and fw version of backup server is: Firmware Version 42.19 So i did a fw upgrade of my backup server so that both servers are v43.50, and tried a recovery but again cant boot the system. Next I did another archive tape with -I (Interactive) flag: make_tape_recovery -I -x inc_entire=vg00 and tried recovery with it, again no good. I cannot find any error or warnings on ignite log, and I cannot boot hpux. I am only on ISL prompt. This is what i've noticed on the gsp logs: ************* SYSTEM ALERT ************** SYSTEM NAME: mcnfwim1 DATE: 07/27/2003 TIME: 10:18:49 ALERT LEVEL: 6 = Boot possible, pending failure - action required REASON FOR ALERT SOURCE: 8 = I/O SOURCE DETAIL: 6 = disk SOURCE ID: 0 PROBLEM DETAIL: 0 = no problem detail LEDs: RUN ATTENTION FAULT REMOTE POWER FLASH OFF ON ON ON LED State: Boot Failed. Running non-OS code. Check Chassis and Console Logs for error messages. 0x00000060860010B0 00000000 00000000 - type 0 = Data Field Unused 0x58000860860010B0 00006706 1B0A1231 - type 11 = Timestamp 07/27/2003 10:18:49 And another gsp log: Log Entry # 3 : SYSTEM NAME: mcnfwim1 DATE: 07/27/2003 TIME: 10:12:20 ALERT LEVEL: 6 = Boot possible, pending failure - action required SOURCE: 8 = I/O SOURCE DETAIL: 6 = disk SOURCE ID: 0 PROBLEM DETAIL: 0 = no problem detail CALLER ACTIVITY: 1 = test STATUS: 0 CALLER SUBACTIVITY: 0B = implementation dependent REPORTING ENTITY TYPE: 0 = system firmware REPORTING ENTITY ID: 00 0x00000060860010B0 00000000 00000000 type 0 = Data Field Unused 0x58000860860010B0 00006706 1B0A0C14 type 11 = Timestamp 07/27/2003 10:12:20 Type CR for next entry, - CR for previous entry, Q CR to quit. Please note that I can not change anything on the production server. I can only make changes to the backup server. Any help is appreciated.

    Read the article

  • .htaccess - Too many redirects

    - by Knocks X
    I am getting a "too many redirects" error from the following two .htaccess files. .htaccess on domain 1 Redirect 301 / http://www.domain2.com/ .htaccess on domain 2 RewriteEngine On RewriteBase / RewriteCond %{HTTP_HOST} !^www\. RewriteRule (.*) http://www.%{HTTP_HOST}/$1 [L,R] RewriteCond %{REQUEST_FILENAME} !-f RewriteCond %{REQUEST_FILENAME} !-d RewriteRule .* /forum/ [L,R] RedirectMatch permanent ^/$ /forum/ # Options +FollowSymlinks RewriteCond %{HTTP_REFERER} badsite1\.com [NC,OR] RewriteCond %{HTTP_REFERER} badsite2\.com [NC] RewriteRule .* - [F] Anyone know the reason for the too many redirects error?

    Read the article

  • Standby Internet connection by means of 3G Modem if Internet Fails

    - by Sarah Boss
    In my office I have 4 computers connected to the Internet with a DIR-615 Wireless N 300 router which gives Internet to all pc's via Ethernet cable. But sometimes this Internet goes off and I have to call the ISP and it takes them 2 days to repair it. I wanted to know if in such cases, can I connect my two zte 3g usb modems to this DIR-615 Wirless N300 router and get emergency Internet in my office? What other steps are required to set up this fail-safe connection?

    Read the article

  • High I/O latency with software RAID, LUKS encrypted and LVM partitioned KVM setup

    - by aef
    I found out a performance problems with a Mumble server, which I described in a previous question are caused by an I/O latency problem of unknown origin. As I have no idea what is causing this and how to further debug it, I'm asking for your ideas on the topic. I'm running a Hetzner EX4S root server as KVM hypervisor. The server is running Debian Wheezy Beta 4 and KVM virtualisation is utilized through LibVirt. The server has two different 3TB hard drives as one of the hard drives was replaced after S.M.A.R.T. errors were reported. The first hard disk is a Seagate Barracuda XT ST33000651AS (512 bytes logical, 4096 bytes physical sector size), the other one a Seagate Barracuda 7200.14 (AF) ST3000DM001-9YN166 (512 bytes logical and physical sector size). There are two Linux software RAID1 devices. One for the unencrypted boot partition and one as container for the encrypted rest, using both hard drives. Inside the latter RAID device lies an AES encrypted LUKS container. Inside the LUKS container there is a LVM physical volume. The hypervisor's VFS is split on three logical volumes on the described LVM physical volume: one for /, one for /home and one for swap. Here is a diagram of the block device configuration stack: sda (Physical HDD) - md0 (RAID1) - md1 (RAID1) sdb (Physical HDD) - md0 (RAID1) - md1 (RAID1) md0 (Boot RAID) - ext4 (/boot) md1 (Data RAID) - LUKS container - LVM Physical volume - LVM volume hypervisor-root - LVM volume hypervisor-home - LVM volume hypervisor-swap - … (Virtual machine volumes) The guest systems (virtual machines) are mostly running Debian Wheezy Beta 4 too. We have one additional Ubuntu Precise instance. They get their block devices from the LVM physical volume, too. The volumes are accessed through Virtio drivers in native writethrough mode. The IO scheduler (elevator) on both the hypervisor and the guest system is set to deadline instead of the default cfs as that happened to be the most performant setup according to our bonnie++ test series. The I/O latency problem is experienced not only inside the guest systems but is also affecting services running on the hypervisor system itself. The setup seems complex, but I'm sure that not the basic structure causes the latency problems, as my previous server ran four years with almost the same basic setup, without any of the performance problems. On the old setup the following things were different: Debian Lenny was the OS for both hypervisor and almost all guests Xen software virtualisation (therefore no Virtio, also) no LibVirt management Different hard drives, each 1.5TB in size (one of them was a Seagate Barracuda 7200.11 ST31500341AS, the other one I can't tell anymore) We had no IPv6 connectivity Neither in the hypervisor nor in guests we had noticable I/O latency problems According the the datasheets, the current hard drives and the one of the old machine have an average latency of 4.12ms.

    Read the article

  • Fibre channel long distance woes

    - by Marki
    I need a fresh pair of eyes. We're using a 15km fibre optic line across which fibrechannel and 10GbE is multiplexed (passive optical CWDM). For FC we have long distance lasers suitable up to 40km (Skylane SFCxx0404F0D). The multiplexer is limited by the SFPs which can do max. 4Gb fibrechannel. The FC switch is a Brocade 5000 series. The respective wavelengths are 1550,1570,1590 and 1610nm for FC and 1530nm for 10GbE. The problem is the 4GbFC fabrics are almost never clean. Sometimes they are for a while even with a lot of traffic on them. Then they may suddenly start producing errors (RX CRC, RX encoding, RX disparity, ...) even with only marginal traffic on them. I am attaching some error and traffic graphs. Errors are currently in the order of 50-100 errors per 5 minutes when with 1Gb/s traffic. Optics Here is the power output of one port summarized (collected using sfpshow on different switches) SITE-A units=uW (microwatt) SITE-B ********************************************** FAB1 SW1 TX 1234.3 RX 49.1 SW3 1550nm (ko) RX 95.2 TX 1175.6 FAB2 SW2 TX 1422.0 RX 104.6 SW4 1610nm (ok) RX 54.3 TX 1468.4 What I find curious at this point is the asymmetry in the power levels. While SW2 transmits with 1422uW which SW4 receives with 104uW, SW2 only receives the SW4 signal with similar original power only with 54uW. Vice versa for SW1-3. Anyway the SFPs have RX sensitivity down to -18dBm (ca. 20uW) so in any case it should be fine... But nothing is. Some SFPs have been diagnosed as malfunctioning by the manufacturer (the 1550nm ones shown above with "ko"). The 1610nm ones apparently are ok, they have been tested using a traffic generator. The leased line has also been tested more than once. All is within tolerances. I'm awaiting the replacements but for some reason I don't believe it will make things better as the apparently good ones don't produce ZERO errors either. Earlier there was active equipment involved (some kind of 4GFC retimer) before putting the signal on the line. No idea why. That equipment was eliminated because of the problems so we now only have: the long distance laser in the switch, (new) 10m LC-SC monomode cable to the mux (for each fabric), the leased line, the same thing but reversed on the other side of the link. FC switches Here is a port config from the Brocade portcfgshow (it's like that on both sides, obviously) Area Number: 0 Speed Level: 4G Fill Word(On Active) 0(Idle-Idle) Fill Word(Current) 0(Idle-Idle) AL_PA Offset 13: OFF Trunk Port ON Long Distance LS VC Link Init OFF Desired Distance 32 Km Reserved Buffers 70 Locked L_Port OFF Locked G_Port OFF Disabled E_Port OFF Locked E_Port OFF ISL R_RDY Mode OFF RSCN Suppressed OFF Persistent Disable OFF LOS TOV enable OFF NPIV capability ON QOS E_Port OFF Port Auto Disable: OFF Rate Limit OFF EX Port OFF Mirror Port OFF Credit Recovery ON F_Port Buffers OFF Fault Delay: 0(R_A_TOV) NPIV PP Limit: 126 CSCTL mode: OFF Forcing the links to 2GbFC produces no errors, but we bought 4GbFC and we want 4GbFC. I don't know where to look anymore. Any ideas what to try next or how to proceed? If we can't make 4GbFC work reliably I wonder what the people working with 8 or 16 do... I don't assume that "a few errors here and there" are acceptable. Oh and BTW we are in contact with everyone of the manufacturers (FC switch, MUX, SFPs, ...) Except for the SFPs to be changed (some have been changed before) nobody has a clue. Brocade SAN Health says the fabric is ok. MUX, well, it's passive, it's only a prism, nature at it's best. Any shots in the dark? APPENDIX: Answers to your questions @Chopper3: This is the second generation of Brocades exhibiting the problem. Before we had 5000s, now we have 5100s. In the beginning when we still had the active MUX we rented a longdistance laser once to put it into the switch directly in order to make tests for a day, during that day of course it was clean. But as I said, sometimes it's clean just like that. And sometimes it's not. Alternative switches would mean to rebuild the entire SAN with those only to test. Alternative SFPs, well they're hard to come by just like that. @longneck: The line is rented. It's a dark fibre (9um monomode) so there's noone else on it. Sure there are splices. I can't go and look but I have to trust they have been done correctly. As I said the line has been checked and rechecked (using an optical time-domain reflectometer). Obviously you don't have all this equipment yourself because it's way too expensive. @mdpc: What would be the "wrong" type of cable according to you? Up to the switch everything is monomode, yes. The connectors are the correct ones too. Yeah I know there are the green ones where the fibre is cut off at a certain angle etc. But we have the correct ones for all that I know. Progress Report #1 We have had two fabrics (=2x2 switches) with Brocade 5100s with FabricOS 6.4.1 and two fabrics (another 2x4 switches) on FabricOS 7.0.2. On the longdistance ISLs (one in each fabric) it turned out that with FOS 6.4.1 setting it to long distance issues warnings about the VC Init setting and consequently the fill word. But those are only warnings. FOS 7.0.2 requires you to do modifications to VCI and the fillword for long distance links. Setting FOS 6.4.1 to the LS (long-distance static distance) setting with wrong VCI and fillword setting made the whole fabric inoperational (stuck in an SCN loop, use fabriclog -s to see, you don't see it anywhere else, no port error counters or anything increasing). Currently I'm giving the one fabric with the IMHO more correct settings a beating and it seems to do fine, whereas the other one without much traffic still has errors here and there. In short: We have eliminated the active part of the MUX (the FC retimer). We are putting the long distance SFPs into the end equipment themselves. Just to be sure we bought new monomode cables to connect the end equipment to the remaining passive part of the MUX. We are now trying out several long distance configs. It's almost black magic. Everything that happens is mostly empirical, noone seems to have a clue what are the exact reasons to do something. ("We have tried this, and it didn't work, then we tried that and it worked, so we stuck with that." But noone really seems to know why.) I'll keep you updated. Progress Report #2 We got the new lasers for one of the fabrics on warranty. It's ultra clean even on 4GbFC. They're transmitting with roughly 2mW (3dBm) whereas the others are only at 1.5mW (1.5dBm) although that should really be enough. The other fabric (where the lasers are apparently ok) still produces one or two CRCs infrequently. Using sfpshow the SFP producing the actual RX errors shows Status/Ctrl: 0x82 Alarm flags[0,1] = 0x5, 0x40 Warn Flags[0,1] = 0x5, 0x40 Now I'll have to find out what that means. Not sure if it was there before. Well I'll first clear my head with a week of vacation. 8-)

    Read the article

  • Slow ASP.NET site using IIS6

    - by lars
    Hi, I have two servers, one virtual and one physical, running the exact same site on both machines. Both machines are running on ~ 2% CPU load and very much RAM available for usage. Somehow the site, with cache turned off ofcourse, loads in ~ 500ms on the virtual machine (which is a dev-server by the way) but almost 3 full seconds on the physical machine. They're both running Server 2003, IIS6 aswell as asp.net version 2.0 Any ideas where I can start troubleshoot this? Best Regards LP

    Read the article

< Previous Page | 451 452 453 454 455 456 457 458 459 460 461 462  | Next Page >