Search Results

Search found 2316 results on 93 pages for 'cmd'.

Page 46/93 | < Previous Page | 42 43 44 45 46 47 48 49 50 51 52 53  | Next Page >

  • Excel Reader ASP.NET

    - by user304429
    I declared a DataGrid in a ASP.NET View and I'd like to generate some C# code to populate said DataGrid with an Excel spreadsheet (.xlsx). Here's the code I have: <asp:DataGrid id="DataGrid1" runat="server"/> <script language="C#" runat="server"> protected void Page_Load(object sender, EventArgs e) { string connString = @"Provider=Microsoft.Jet.OLEDB.4.0;Data Source=c:\FileName.xlsx;Extended Properties=""Excel 12.0;HDR=YES;"""; // Create the connection object OleDbConnection oledbConn = new OleDbConnection(connString); try { // Open connection oledbConn.Open(); // Create OleDbCommand object and select data from worksheet Sheet1 OleDbCommand cmd = new OleDbCommand("SELECT * FROM [sheetname$]", oledbConn); // Create new OleDbDataAdapter OleDbDataAdapter oleda = new OleDbDataAdapter(); oleda.SelectCommand = cmd; // Create a DataSet which will hold the data extracted from the worksheet. DataSet ds = new DataSet(); // Fill the DataSet from the data extracted from the worksheet. oleda.Fill(ds, "Something"); // Bind the data to the GridView DataGrid1.DataSource = ds.Tables[0].DefaultView; DataGrid1.DataBind(); } catch { } finally { // Close connection oledbConn.Close(); } } </script> When I run the website, nothing really happens. What gives?

    Read the article

  • Oracle Data Provider and casting

    - by mrjoltcola
    I use Oracle's specific data provider, not the Microsoft provider that is being discontinued. The thing I've found about ODP.NET is how picky it is with data types. Where JDBC and other ADO providers just convert and make things work, ODP.NET will throw an invalid cast exception unless you get it exactly right. Consider this code: String strSQL = "SELECT DOCUMENT_SEQ.NEXTVAL FROM DUAL"; OracleCommand cmd = new OracleCommand(strSQL, conn); reader = cmd.ExecuteReader(); if (reader != null && reader.Read()) { Int64 id = reader.GetInt64(0); return id; } Due to ODP.NET's pickiness on conversion, this doesn't work. My usual options are: 1) Retrieve into a Decimal and return it with a cast to an Int64 (I don't like this because Decimal is just overkill, and at least once I remember reading it was deprecated...) Decimal id = reader.GetDecimal(0); return (Int64)id; 2) Or cast in the SQL statement to make sure it fits into Int64, like NUMBER(18) String strSQL = "SELECT CAST(DOCUMENT_SEQ.NEXTVAL AS NUMBER(18)) FROM DUAL"; I do (2), because I feel its just not clean pulling a number into a .NET Decimal when my domain types are Int32 or Int64. Other providers I've used are nice (smart) enough to do the conversion on the fly. Any suggestions from the ODP.NET gurus?

    Read the article

  • how I can print WPF treeview items over multiple pages?

    - by RAJKISHOR
    Hello friend, I want to print tree structure showing in WPF treeview control in multiple page. I tried PrintVisual() but it only prints only visible parts. Then I tried FlowDocument and written AddNode(), but its not showing the same result as treeview doimg. Please help me with code. public void AddNodes(int uid, ListItem tSubNode) { string query = "select fullname, id from members where refCode=" + uid + ";"; String memValue; MySqlCommand cmd = new MySqlCommand(query, db.conn); MySqlDataAdapter _DA = new MySqlDataAdapter(cmd); DataTable _DT = new DataTable(); _DA.Fill(_DT); ListOffset += 20; foreach (DataRow _dr in _DT.Rows) { ListItem tNode = new ListItem(); tNode.Margin = new Thickness(ListOffset,0,0,0); memValue = _dr["fullname"].ToString() + " (" + _dr["id"].ToString() + ")"; tNode.Blocks.Add(new Paragraph(new Run(hyp+memValue))); myList.ListItems.Add(tNode); flowDoc.Blocks.Add(myList); _fdrMembers.Document = flowDoc; if (db.HasMembers(Convert.ToInt32(_dr["id"].ToString()))) { AddNodes(Convert.ToInt32(_dr["id"]), tNode); } } ListOffset = 20; } private void button_Click(object sender, RoutedEventArgs e) { ListOffset = 0; myList.ListItems.Clear(); tSuper.Blocks.Clear(); if (db.GetNameByUID(100001) != null) { tSuper.Blocks.Add(new Paragraph(new Run(db.GetNameByUID(100001)))); myList.ListItems.Add(tSuper); AddNodes(100001, tSuper); } MessageBox.Show("Member by ID - "+does.ToString()+", "+dosnt.ToString(), "Error!", MessageBoxButton.OK, MessageBoxImage.Information); }**strong text**

    Read the article

  • Trying to build the basic python extension example fails (windows)

    - by Alexandros
    Hello, I have Python 2.6 and Visual Studio 2008 running on a Win7 x64 machine. When I try to build the basic python extension example in c "example_nt" as found in the python 2.6 sources distribution, it fails: python setup.py build And this results in: running build running build_ext building 'aspell' extension Traceback (most recent call last): File "setup.py", line 7, in <module> ext_modules = [module1]) File "C:\Python26\lib\distutils\core.py", line 152, in setup dist.run_commands() File "C:\Python26\lib\distutils\dist.py", line 975, in run_commands self.run_command(cmd) File "C:\Python26\lib\distutils\dist.py", line 995, in run_command cmd_obj.run() File "C:\Python26\lib\distutils\command\build.py", line 134, in run self.run_command(cmd_name) File "C:\Python26\lib\distutils\cmd.py", line 333, in run_command self.distribution.run_command(command) File "C:\Python26\lib\distutils\dist.py", line 995, in run_command cmd_obj.run() File "C:\Python26\lib\distutils\command\build_ext.py", line 343, in run self.build_extensions() File "C:\Python26\lib\distutils\command\build_ext.py", line 469, in build_extensions self.build_extension(ext) File "C:\Python26\lib\distutils\command\build_ext.py", line 534, in build_extension depends=ext.depends) File "C:\Python26\lib\distutils\msvc9compiler.py", line 448, in compile self.initialize() File "C:\Python26\lib\distutils\msvc9compiler.py", line 358, in initialize vc_env = query_vcvarsall(VERSION, plat_spec) File "C:\Python26\lib\distutils\msvc9compiler.py", line 274, in query_vcvarsall raise ValueError(str(list(result.keys()))) ValueError: [u'path'] What can I do to fix this? Any help will be appreciated

    Read the article

  • SharePoint Visual web part and Oracle connection problem

    - by Rishi
    Hi, I'm trying to build a "visual web part" for SharePoint 2010 which should connect to Oracle table and display records on SharePoint page.For development, Oracle 11g client (with ODP.net) ,SharePoint server 2010, Visual Studio 2010 and Oracle 10g express all running on my machine. First,I've written sample code in ASP.NET web app to connect my local Oracle table and display data in grid view and it works fine. My code is , OracleConnection con; try { // Connect string constr = "Data Source=(DESCRIPTION=(ADDRESS_LIST=(ADDRESS=(PROTOCOL=TCP)(HOST=localhost)(PORT=1521)))(CONNECT_DATA=(SERVER=DEDICATED)(SERVICE_NAME=XE)));User Id=SYSTEM; Password=password"; con = new OracleConnection(constr); //Open database connection con.Open(); // Execute a SQL SELECT OracleCommand cmd = new OracleCommand("select * from T_ACTIONPOINTS WHERE AP_STATUS='Active' ", con); OracleDataReader dr = cmd.ExecuteReader(); GridView.DataSource = dr; GridView.DataBind(); GridView.AllowPaging = true; } catch (Exception e) { lblError.Text = e.Message; } Now, I'm trying to create new "SharePoint" visual web part project and using same code and deploying it on my local SP server. But when it runs , I get following error here is my solution explorer, It looks something wrong in compatibility.Can someone point me in right direction ?

    Read the article

  • Bind SQLiteDataReader to GridView in ASP.NET

    - by Charles Gargent
    Hi, this is all rather new to me, but I have searched for a good while and cant find any idea why I cant get this to work, dr looks like it is populated but I get this nullreferenceexeception when I try to bind to the gridview Thanks code SQLiteConnection cnn = new SQLiteConnection(@"Data Source=c:\log.db"); cnn.Open(); SQLiteCommand cmd = new SQLiteCommand(@"SELECT * FROM evtlog", cnn); SQLiteDataReader dr = cmd.ExecuteReader(); GridView1.DataSource = dr; GridView1.DataBind(); dr.Close(); cnn.Close(); Codebehind <asp:ContentPlaceHolder ID="MainContent" runat="server"> <asp:GridView ID="GridView1" runat="server"> </asp:GridView> </asp:ContentPlaceHolder> error Object reference not set to an instance of an object. at WPKG_Report.SiteMaster.Button1_Click(Object sender, EventArgs e) in C:\Projects\Report\Site.Master.cs:line 32 at System.Web.UI.WebControls.Button.OnClick(EventArgs e) at System.Web.UI.WebControls.Button.RaisePostBackEvent(String eventArgument) at System.Web.UI.WebControls.Button.System.Web.UI.IPostBackEventHandler.RaisePostBackEvent(String eventArgument) at System.Web.UI.Page.RaisePostBackEvent(IPostBackEventHandler sourceControl, String eventArgument) at System.Web.UI.Page.RaisePostBackEvent(NameValueCollection postData) at System.Web.UI.Page.ProcessRequestMain(Boolean includeStagesBeforeAsyncPoint, Boolean includeStagesAfterAsyncPoint)

    Read the article

  • Web form is not updating tables, why?

    - by JPJedi
    I have a web application and on page is an update page to update some profile information. Below is the code I am using to update the table. But I think it is wrong. Does anything stick out? The connection string works cause it is used to read the database to get the profile information, I just removed it due to it containing password/login info for the db. player is the class of properties that contains player information and ds is the dataset, but I would like to update the database itself online... Dim connectionString As String = "" Dim GigsterDBConnection As New System.Data.SqlClient.SqlConnection(connectionString) GigsterDBConnection.Open() Dim updatetoursql As String = "UPDATE PLAYERS SET FIRSTNAME = '" & player.FIRSTNAME & "', LASTNAME = '" & player.LASTNAME & "', ADDRESS = '" & player.ADDRESS & "', CITY = '" & player.CITY & "', ZIP = '" & player.ZIP & "', PHONE = '" & player.PHONE & "', EMAIL = '" & player.EMAIL & "', REFFEREDBY = '" & player.REFEREDBY & "' " updatetoursql = updatetoursql & "PLAYERID = '" & player.PLAYERID & "';" Dim cmd As New System.Data.SqlClient.SqlCommand(updatetoursql, GigsterDBConnection) Dim sqlAdapter As New System.Data.SqlClient.SqlDataAdapter(cmd) sqlAdapter.Update(ds, "PLAYERS") I think the issue is something the 3 last lines of the code. am I doing it right or is their a better way? Thanks

    Read the article

  • How to run R through PHP with exec?

    - by dkar
    I am going to ask something, that I know that it has been asked already some times. But since, all of the past posts are quite old and none of them answer my problem..I try again. I am completely new in R language and relative new in php. What I want to do is to use the exec() function from php in order to execute a R script. Most of the people here will start talking about rapache, rserve and I don't know what else..but since I am not familiar with all these technologies, I prefer just using exec. The code I will show here is working just fine when I run it with Rscript from the terminal. # R script png("temp.png") plot(5,5) dev.off() But when I try to run it either with Rscript or with R CMD BATCH from PHP, like this: echo exec("Rscript my_rscript.R"); //OR //echo exec("R CMD BATCH my_rscript.R"); I get nothing back. I have checked if exec() function is available and if it works. Everything is ok with this. I read also, that I might have to change the permissions of the webserver...but I don't know how to do this in mamp. I hope I am clear with my problem and someone can help. Thanks Dimitris

    Read the article

  • SD card initialization using SPI interface

    - by Tobias
    I get invalid response Codes from my SD Card(CMD8, CMD55, CMD41) Init routine: SDCS = 1; // MMC deaktiviert SPI1CON1bits.SMP = 0; SPI1CON1bits.CKE = 1; SPI1CON1bits.MSTEN = 1; SPI1CON1bits.CKP = 0; SPI1STATbits.SPIEN = 1; for(i=0;i<10;i++) SPI(0xFF); // RESET unsigned char rr=Command(CMD0,0); SDCS=1; // MMC deactivated /*OK response == 1*/ r=Command(CMD8,0); // check voltage SDCS=1; /* response == 0xC1 ?!? */ r = Command(CMD58,0); // READ_OCR unsigned char ocr1 = SPI(0xFF); unsigned char ocr2 = SPI(0xFF); unsigned char ocr3 = SPI(0xFF); unsigned char ocr4 = SPI(0xFF); unsigned char ocr5 = SPI(0xFF); /* r = 0xF8; ?!? ocr1 = 0x0F; ocr2 = 0xFF; ocr3 = 0xFF; ocr4 = 0xFF; ocr5 = 0xFF; */ SDCS=1; // INIT unsigned char rrr = 0; i=10000; do { rrr=Command(55,0); // Next is APP CMD SDCS=1; if(r) break; }while(--i>0); /* OK response == 1 */ // APP CMD 41 with OCR = 0x0F?? You can read the response codes in the comments. Is it possible the response code to CMD8 is 0xC1? Bit 7 should be 0, right? Is it a hardware error?

    Read the article

  • sorting filtered data in asp.net listview

    - by user791345
    I've created a listview that's filled up with a list of guitars from the database on page load like so: protected void Page_Load(object sender, EventArgs e) { SqlConnection con = new SqlConnection(WebConfigurationManager.ConnectionStrings["GuitarsLTDBConnectionString"].ToString()); SqlCommand cmd = new SqlCommand("SELECT * FROM Guitars", con); SqlDataAdapter da = new SqlDataAdapter(cmd.CommandText, con); DataTable dt = new DataTable(); da.Fill(dt); lvGuitars.DataSource = dt; lvGuitars.DataBind(); } The following code filters that list of guitars by a certain Make when the user checks the checkbox corresponding to that make protected void chkOrgs_SelectedIndexChanged(object sender, EventArgs e) { DataTable dt = (DataTable)lvGuitars.DataSource; DataView dv = new DataView(dt); if (chkOrgs.SelectedValue == "Gibson") { dv.RowFilter = "Make = 'Gibson' OR Make='Fender'"; } lvGuitars.DataSource = dv.ToTable(); lvGuitars.DataBind(); } Now, what I want to do is be able to sort the latest data that is present within the listview. Meaning, if sort is clicked before filtering, the it should sort all data. If sort is clicked after filtering, it should sort the filtered data. I'm using the following code, which is triggered upon a LinkButton click protected void lnkSortResults_Click(object sender, EventArgs e) { DataTable dt = (DataTable)lvGuitars.DataSource; DataView dv = new DataView(dt); dv.Sort = "Make ASC"; lvGuitars.DataSource = dv.ToTable(); lvGuitars.DataBind(); } The problem is that all the data that the listview was loaded with before any filtering is sorted, and not the latest filtered data. How can I change this code so that the latest data available in the listview is the one that's sorted? Thanks

    Read the article

  • sql statement supposed to have 2 distinct rows, but only 1 is returned. for C# windows

    - by jello
    yeah so I have an sql statement that is supposed to return 2 rows. the first with psychological_id = 1, and the second, psychological_id = 2. here is the sql statement select * from psychological where patient_id = 12 and symptom = 'delire'; But with this code, with which I populate an array list with what is supposed to be 2 different rows, two rows exist, but with the same values: the second row. OneSymptomClass oneSymp = new OneSymptomClass(); ArrayList oneSympAll = new ArrayList(); string connStrArrayList = "Data Source=.\\SQLEXPRESS;AttachDbFilename=|DataDirectory|\\PatientMonitoringDatabase.mdf; " + "Initial Catalog=PatientMonitoringDatabase; " + "Integrated Security=True"; string queryStrArrayList = "select * from psychological where patient_id = " + patientID.patient_id + " and symptom = '" + SymptomComboBoxes[tag].SelectedItem + "';"; using (var conn = new SqlConnection(connStrArrayList)) using (var cmd = new SqlCommand(queryStrArrayList, conn)) { conn.Open(); using (SqlDataReader rdr = cmd.ExecuteReader()) { while (rdr.Read()) { oneSymp.psychological_id = Convert.ToInt32(rdr["psychological_id"]); oneSymp.patient_history_date_psy = (DateTime)rdr["patient_history_date_psy"]; oneSymp.strength = Convert.ToInt32(rdr["strength"]); oneSymp.psy_start_date = (DateTime)rdr["psy_start_date"]; oneSymp.psy_end_date = (DateTime)rdr["psy_end_date"]; oneSympAll.Add(oneSymp); } } conn.Close(); } OneSymptomClass testSymp = oneSympAll[0] as OneSymptomClass; MessageBox.Show(testSymp.psychological_id.ToString()); the message box outputs "2", while it's supposed to output "1". anyone got an idea what's going on?

    Read the article

  • ASP.NET DropDownList posting ""

    - by Daniel
    I am using ASP.NET forms version 3.5 in VB I have a dropdownlist that is filled with data from a DB with a list of countries The code for the dropdown list is <label class="ob_label"> <asp:DropDownList ID="lstCountry" runat="server" CssClass="ob_forminput"> </asp:DropDownList> Country*</label> And the code that the list is Dim selectSQL As String = "exec dbo.*******************" ' Define the ADO.NET objects. Dim con As New SqlConnection(connectionString) Dim cmd As New SqlCommand(selectSQL, con) Dim reader As SqlDataReader ' Try to open database and read information. Try con.Open() reader = cmd.ExecuteReader() ' For each item, add the author name to the displayed ' list box text, and store the unique ID in the Value property. Do While reader.Read() Dim newItem As New ListItem() newItem.Text = reader("AllSites_Countries_Name") newItem.Value = reader("AllSites_Countries_Id") CType(LoginViewCart.FindControl("lstCountry"), DropDownList).Items.Add(newItem) Loop reader.Close() CType(LoginViewCart.FindControl("lstCountry"), DropDownList).SelectedValue = 182 Catch Err As Exception Response.Redirect("~/error-on-page/") MailSender.SendMailMessage("*********************", "", "", OrangeBoxSiteId.SiteName & " Error Catcher", "<p>Error in sub FillCountry</p><p>Error on page:" & HttpContext.Current.Request.Url.AbsoluteUri & "</p><p>Error details: " & Err.Message & "</p>") Response.Redirect("~/error-on-page/") Finally con.Close() End Try When the form is submitted an error occurs which says that the string "" cannot be converted to the datatype integer. For some reason the dropdownlist is posting "" rather than the value for the selected country.

    Read the article

  • dig works but dig +trace <domain_name> not working

    - by anoopmathew
    In my local system i can't get the proper result of dig +trace , but dig works fine. I'm using Ubuntu 10.04 LTS version. I'll attach the result of dig and dig +trace along with this updates. dig +trace gmail.com ; << DiG 9.7.0-P1 << +trace gmail.com ;; global options: +cmd ;; Received 12 bytes from 4.2.2.4#53(4.2.2.4) in 291 ms dig gmail.com ; << DiG 9.7.0-P1 << gmail.com ;; global options: +cmd ;; Got answer: ;; -HEADER<<- opcode: QUERY, status: NOERROR, id: 59528 ;; flags: qr rd ra; QUERY: 1, ANSWER: 2, AUTHORITY: 0, ADDITIONAL: 0 ;; QUESTION SECTION: ;gmail.com. IN A ;; ANSWER SECTION: gmail.com. 49 IN A 74.125.236.118 gmail.com. 49 IN A 74.125.236.117 ;; Query time: 302 msec ;; SERVER: 4.2.2.4#53(4.2.2.4) ;; WHEN: Sat Oct 13 14:57:56 2012 ;; MSG SIZE rcvd: 59 Please anyone update a solution for this issue. I'm just worried about my issue.

    Read the article

  • Why is my GUI unresponsive while a SwingWorker thread runs?

    - by Starchy
    Hello, I have a SwingWorker thread with an IOBound task which is totally locking up the interface while it runs. Swapping out the normal workload for a counter loop has the same result. The SwingWorker looks basically like this: public class BackupWorker extends SwingWorker<String, String> { private static String uname = null; private static String pass = null; private static String filename = null; static String status = null; BackupWorker (String uname, String pass, String filename) { this.uname = uname; this.pass = pass; this.filename = filename; } @Override protected String doInBackground() throws Exception { BackupObject bak = newBackupObject(uname,pass,filename); return "Done!"; } } The code that kicks it off lives in a class that extends JFrame: public void actionPerformed(ActionEvent event) { String cmd = event.getActionCommand(); if (BACKUP.equals(cmd)) { SwingUtilities.invokeLater(new Runnable() { public void run() { final StatusFrame statusFrame = new StatusFrame(); statusFrame.setVisible(true); SwingUtilities.invokeLater(new Runnable() { public void run () { statusFrame.beginBackup(uname,pass,filename); } }); } }); } } Here's the interesting part of StatusFrame: public void beginBackup(final String uname, final String pass, final String filename) { worker = new BackupWorker(uname, pass, filename); worker.execute(); try { System.out.println(worker.get()); } catch (InterruptedException e) { e.printStackTrace(); } catch (ExecutionException e) { e.printStackTrace(); } } } So far as I can see, everything "long-running" is handled by the worker, and everything that touches the GUI on the EDT. Have I tangled things up somewhere, or am I expecting too much of SwingWorker?

    Read the article

  • Java Process.waitFor() and IO streams

    - by lynks
    I have the following code; String[] cmd = { "bash", "-c", "~/path/to/script.sh" }; Process p = Runtime.getRuntime().exec(cmd); PipeThread a = new PipeThread(p.getInputStream(), System.out); PipeThread b = new PipeThread(p.getErrorStream(), System.err); p.waitFor(); a.die(); b.die(); The PipeThread class is quite simple so I will include it in full; public class PipeThread implements Runnable { private BufferedInputStream in; private BufferedOutputStream out; public Thread thread; private boolean die = false; public PipeThread(InputStream i, OutputStream o) { in = new BufferedInputStream(i); out = new BufferedOutputStream(o); thread = new Thread(this); thread.start(); } public void die() { die = true; } public void run() { try { byte[] b = new byte[1024]; while(!die) { int x = in.read(b, 0, 1024); if(x > 0) out.write(b, 0, x); else die(); out.flush(); } } catch(Exception e) { e.printStackTrace(); } try { in.close(); out.close(); } catch(Exception e) { } } } My problem is this; p.waitFor() blocks endlessly, even after the subprocess has terminated. If I do not create the pair of PipeThread instances, then p.waitFor() works perfectly. What is it about the piping of io streams that is causing p.waitFor() to continue blocking? I'm confused as I thought the IO streams would be passive, unable to keep a process alive, or to make Java think the process is still alive.

    Read the article

  • Sending and receiving IM messages via controller in Rails

    - by Grnbeagle
    Hi, I need a way to handle XMPP communication in my Rails app. My requirements are: Keep an instance of XMPP client running and logged in as one specific user (my bot user) Trigger an event from a controller to send a message and wait for a reply. The message is sent to another machine equipped with a bot so that the reply is supposed to be returned quickly. I installed xmpp4r and backgrounDrb similar to what's described here, but backgrounDrb seems to have evolved and I couldn't get it to wait for a reply. If it has to happen asynchronously, I am willing to use a server-push technology to notify the browser when the reply arrives. To give you a better idea, here are snippets of my code: (In controller) class ServicesController < ApplicationController layout 'simple' def index render :text => "index" end def show @my_service = Service.find(params[:id]) worker = MiddleMan.worker(:jabber_agent_worker) worker.send_request(:arg => {:jid => "someuser@someserver", :cmd => "help"}) render :text => "testing" end end (In worker script) require 'xmpp4r' require 'logger' class JabberAgentWorker < BackgrounDRb::MetaWorker set_worker_name :jabber_agent_worker def create(args = nil) jid = Jabber::JID.new('myagent@myserver') @client = Jabber::Client.new(jid) @client.connect @client.auth('pass') @client.send(Jabber::Presence.new.set_show(:chat).set_status('BackgrounDRb')) @client.add_message_callback do |message| logger.info("**** messaged received: #{message}") # never reaches here end end def send_request(args = nil) to_jid = Jabber::JID.new(args[:jid]) message = Jabber::Message::new(to_jid, args[:cmd]).set_type(:normal).set_id('1') @client.send(message) end end If anyone can tell me any of the following, I'd much appreciate it: issue with my backgrounDrb usage other background process alternatives appropriate for XMPP interactions other ways of achieving this Thanks in advance.

    Read the article

  • exec() in BeanShell macro causes jEdit to hang when it returns non-zero exit code

    - by rossmeissl
    I have a jEdit BeanShell macro that runs my Markdown files through Maruku when I save them: if (buffer.getMode().toString().equals("markdown")) { cmd = "C:\\Ruby\\bin\\maruku.bat -o " + buffer.getDirectory() + buffer.getName().replaceAll("markdown$", "html") + " " + buffer.getPath(); exec(cmd); } This works great when the Markdown file is valid. But if I've made a mistake, jEdit just waits around forever for the exec() call to "succeed," which it never will. When this happens, I have to kill jEdit's javaw.exe process and run Maruku manually from the command line to discover the error, e.g.: E:\bp\plan\supply_chain>maruku business_plan.markdown ___________________________________________________________________________ | Maruku tells you: +--------------------------------------------------------------------------- | Could not find ref_id = "17" for md_link(["17"],"17") | Available refs are [] +--------------------------------------------------------------------------- !C:/Ruby/lib/ruby/gems/1.8/gems/maruku-0.6.0/lib/maruku/errors_management.rb:49:in `maruku_error' !C:/Ruby/lib/ruby/gems/1.8/gems/maruku-0.6.0/lib/maruku/output/to_html.rb:716:in `to_html_link' !C:/Ruby/lib/ruby/gems/1.8/gems/maruku-0.6.0/lib/maruku/output/to_html.rb:970:in `send' !C:/Ruby/lib/ruby/gems/1.8/gems/maruku-0.6.0/lib/maruku/output/to_html.rb:970:in `array_to_html' !C:/Ruby/lib/ruby/gems/1.8/gems/maruku-0.6.0/lib/maruku/output/to_html.rb:961:in `each' \___________________________________________________________________________ Not creating a link for ref_id = "17". Then I restart jEdit, fix the error, and re-save the file, at which point the macro succeeds. How can I make my macro more resilient to either die helpfully (display Maruku's error output) or, at the very least, die silently so I don't have to kill jEdit?

    Read the article

  • paypal sadbox IPN

    - by Phil Jackson
    Morning all. I am trying to test a SIMPLE php script to deal with the IPN response from paypal sandbox. <?php // read the post from PayPal system and add 'cmd' $req = 'cmd=_notify-validate'; foreach ($post as $key => $value) { $value = urlencode(stripslashes($value)); $req .= "&$key=$value"; } // post back to PayPal system to validate $header = "POST /cgi-bin/webscr HTTP/1.0\r\n"; $header .= "Content-Type: application/x-www-form-urlencoded\r\n"; $header .= "Content-Length: " . strlen($req) . "\r\n\r\n"; $fp = fsockopen ('ssl://www.sandbox.paypal.com/', 443, $errno, $errstr, 30); if ( !$fp ) { // HTTP ERROR $fp = fopen('thinbg.txt', 'a'); fwrite($fp, "false !fp - " . implode(" ", $post) ); fclose($fp); } else { fputs ($fp, $header . $req); while (!feof($fp)) { $res = fgets ($fp, 1024); if (strcmp ($res, "VERIFIED") == 0) { // PAYMENT VALIDATED & VERIFIED! $fp2 = fopen('thinbg.txt', 'a'); fwrite($fp2, "true - " . implode(" ", $post) ); fclose($fp2); } else if (strcmp ($res, "INVALID") == 0) { // PAYMENT INVALID & INVESTIGATE MANUALY! $fp2 = fopen('thinbg.txt', 'a'); fwrite($fp2, "false - " . implode(" ", $post) ); fclose($fp2); } } fclose ($fp); } ?> When I click on "send IPN" in the test ac"IPN successfully sent". when I look at the file that I created to check the vars it begins with "false !fp" yet still displays all the vars. Can anyone see whats happening and how I go about fixing. Regards, Phil

    Read the article

  • Using mercurial and beyond compare 3(bc3) as the diff tool? help needed

    - by mhd
    Hi, in windows I am able to use winmerge as the external diff tool for hg using mercurial.ini,etc. Using some options switch that you can find in web(I think it's a japanese website) Anyway, here for example: hg winmerge -r1 -r2 will list file(s) change(s) between rev1 and rev2 in winmerge. I can just click which file to diff but for bc3: hg bcomp -r1 -r2 will make bc3 open a dialog which stated that a temp dir can't be found. The most I can do using bc3 and hg is hg bcomp -r1 -r2 myfile.cpp which will open diff between rev1 and rev2 of myfile.cpp So,it seems that hg+bc3 can't successfully acknowledge of all files change between revision. Only able to diff 1 file at a time. Anyone can use bc3 + hg better ? edit: Problem Solved ! Got the solution from scooter support page. I have to use bcompare instead of bcomp Here's a snippet of my mercurial.ini [extensions] hgext.win32text = ;mhd adds hgext.extdiff = ;mhd adds for bc [extdiff] cmd.bc3 = bcompare opts.bc3 = /ro ;mhd adds for winmerge ;[extdiff] ;cmd.winmerge = WinMergeU ;opts.winmerge = /r /e /x /ub

    Read the article

  • sql statement supposed to have 2 distinct rows, but only 1 is returned

    - by jello
    I have an sql statement that is supposed to return 2 rows. the first with psychological_id = 1, and the second, psychological_id = 2. here is the sql statement select * from psychological where patient_id = 12 and symptom = 'delire'; But with this code, with which I populate an array list with what is supposed to be 2 different rows, two rows exist, but with the same values: the second row. OneSymptomClass oneSymp = new OneSymptomClass(); ArrayList oneSympAll = new ArrayList(); string connStrArrayList = "Data Source=.\\SQLEXPRESS;AttachDbFilename=|DataDirectory|\\PatientMonitoringDatabase.mdf; " + "Initial Catalog=PatientMonitoringDatabase; " + "Integrated Security=True"; string queryStrArrayList = "select * from psychological where patient_id = " + patientID.patient_id + " and symptom = '" + SymptomComboBoxes[tag].SelectedItem + "';"; using (var conn = new SqlConnection(connStrArrayList)) using (var cmd = new SqlCommand(queryStrArrayList, conn)) { conn.Open(); using (SqlDataReader rdr = cmd.ExecuteReader()) { while (rdr.Read()) { oneSymp.psychological_id = Convert.ToInt32(rdr["psychological_id"]); oneSymp.patient_history_date_psy = (DateTime)rdr["patient_history_date_psy"]; oneSymp.strength = Convert.ToInt32(rdr["strength"]); oneSymp.psy_start_date = (DateTime)rdr["psy_start_date"]; oneSymp.psy_end_date = (DateTime)rdr["psy_end_date"]; oneSympAll.Add(oneSymp); } } conn.Close(); } OneSymptomClass testSymp = oneSympAll[0] as OneSymptomClass; MessageBox.Show(testSymp.psychological_id.ToString()); the message box outputs "2", while it's supposed to output "1". anyone got an idea what's going on?

    Read the article

  • populate checkboxes with database.

    - by amby
    Hi, I have to poulate checkboxes with data coming from database but no checkbox is showing on my page. please give me correct way to do that. in C# file page_load method i m doing this: public partial class dbTest1 : System.Web.UI.Page { protected void Page_Load(object sender, EventArgs e) { string Server = "al2222"; string Username = "hshshshsh"; string Password = "sjjssjs"; string Database = "database1"; string ConnectionString = "Data Source=" + Server + ";"; ConnectionString += "User ID=" + Username + ";"; ConnectionString += "Password=" + Password + ";"; ConnectionString += "Initial Catalog=" + Database; string query = "Select * from Customer_Order where orderNumber = 17"; using (SqlConnection conn = new SqlConnection(ConnectionString)) { using (SqlCommand cmd = new SqlCommand(query, conn)) { conn.Open(); SqlDataReader dr = cmd.ExecuteReader(); while (dr.Read()) { if (!IsPostBack) { Interests.DataSource = dr; Interests.DataTextField = "OptionName"; Interests.DataValueField = "OptionName"; Interests.DataBind(); } } conn.Close(); conn.Dispose(); } } } } and in .aspx using this: <asp:CheckBoxList ID="Interests" runat="server"></asp:CheckBoxList> please tell me correct way to do that.

    Read the article

  • How can click on a java show link programatically?

    - by Jules
    I'm trying to develop a new feature for our vb.net order entry system. At the moment I provide an assisted paypal login which loops through transactions and copies the transactions. My program then looks at this data and copies it into text boxes. The operator then approves and saves the record. So my code uses IHTMLFormElement and loops round form elements and adds values. However I only really use this to log in to paypal. See my code... Dim theObject As Object = Nothing theObject = "https://www.paypal.com/cgi-bin/webscr?cmd=_login-run" WebBrowPayPal.AxWebBrowser1.Navigate2(theObject) While WebBrowPayPal.AxWebBrowser1.ReadyState <> tagREADYSTATE.READYSTATE_COMPLETE Application.DoEvents() End While Dim HtmlDoc As IHTMLDocument2 = CType(WebBrowPayPal.AxWebBrowser1.Document, IHTMLDocument2) Dim FormCol As IHTMLElementCollection = HtmlDoc.forms Dim iForms As Integer = FormCol.length Dim i As Integer Dim x As Integer For i = 0 To iForms - 1 Dim oForm As IHTMLFormElement = CType(FormCol.item(CType(i, Object), CType(i, Object)), IHTMLFormElement) For x = 0 To oForm.length - 1 If oForm.elements(x).tagname = "INPUT" Then If oForm.elements(x).name = "login_email" Then oForm.elements(x).value = "[email protected]" End If If oForm.elements(x).name = "login_password" Then oForm.elements(x).value = "mypassword" End If If oForm.elements(x).type = "submit" Or _ oForm.elements(x).type = "SUBMIT" Then oForm.elements(x).click() End If End If Next Next i I'm now trying this page https://www.paypal.com/uk/cgi-bin/webscr?cmd=_history&nav=0.3.0 Which is the history page, which allows you to search on the paypal transaction id. Unfortunately you need to click on 'find a transaction' which then uses some javascript to shows the post fields. So the problem is that the fields I need to use are hidden. How can I click on this java link in code ?

    Read the article

  • Problem using SQLDataReader with Sybase ASE

    - by John K.
    We're developing a reporting application that uses asp.net-mvc (.net 4). We connect through DDTEK.Sybase middleware to a Sybase ASE 12.5 database. We're having a problem pulling data into a datareader (from a stored procedure). The stored procedure computes values (approximately 50 columns) by doing sums, counts, and calling other stored procedures. The problem we're experiencing is... certain (maybe 5% of the columns) come back with NULL or 0. If we debug and copy the SQL statement being used for the datareader and run it inside another SQL tool we get all valid values for all columns. conn = new SybaseConnection { ConnectionString = ConfigurationManager.ConnectionStrings[ConnectStringName].ToString() }; conn.Open(); cmd = new SybaseCommand { CommandTimeout = cmdTimeout, Connection = conn, CommandText = mainSql }; reader = cmd.ExecuteReader(); // AT THIS POINT IMMEDIATELY AFTER THE EXECUTEREADER COMMAND // THE READER CONTAINS THE BAD (NULL OR 0) DATA FOR THESE COLUMNS. DataTable schemaTable = reader.GetSchemaTable(); // AT THIS POINT WE CAN VIEW THE DATATABLE FOR THE SCHEMA AND IT APPEARS CORRECT // THE COLUMNS THAT DON'T WORK HAVE SPECIFICATIONS IDENTICAL TO THE COLUMNS THAT DO WORK Has anyone had problems like this using Sybase and ADO? Thanks, John K.

    Read the article

  • google chrome extension update text after response callback

    - by Jerome
    I am writing a Google Chrome extension. I have reached the stage where I can pass messages back and forth readily but I am running into trouble with using the response callback. My background page opens a message page and then the message page requests more information from background. When the message page receives the response I want to replace some of the standard text on the message page with custom text based on the response. Here is the code: chrome.extension.sendRequest({cmd: "sendKeyWords"}, function(response) { keyWordList=response.keyWordsFound; var keyWords=""; for (var i = 0; i FIRST QUESTION: This all seems to work fine but the text on the page doesn't change. I am almost certainly because the callback completes after the page is finished loading and the rest of the code finishes before the callback completes, too. How do I update the page with the new text? Can I listen for the callback to complete or something like that? SECOND QUESTION: The procedure I am pursuing first opens the message page and then the message page requests the keyword list from background. Since I always want the keyword list, it makes more sense to just send it when I create the tab. Can I do that? Here is the code from background that opens the message page: //when request from detail page to open message page chrome.extension.onRequest.addListener(function(request, sender, sendResponse) { if(request.cmd == "openMessage") { console.log("Received Request to Open Message, Profile Score: "+request.keyWordsFound.length); keyWordList=request.keyWordsFound; chrome.tabs.create({url: request.url}, function(tab){ msgTabId=tab.id; //needed to determine if message tab has later been closed chrome.tabs.executeScript(tab.id, {file: "message.js"}); }); console.log("Opening Message"); } });

    Read the article

  • Extract data from PostgreSQL DB without using pg_dump

    - by John Horton
    There is a PostgreSQL database on which I only have limited access (e.g, I can't use pg_dump). I am trying to create a local "mirror" by exporting certain tables from the database. I do not have the permissions needed to just dump a table as SQL from within psql. Right now, I just have a Python script that iterates through my table_names, selects all fields and then exports them as a CSV: for table_name, file_name in zip(table_names, file_names): cmd = """echo "\\\copy (select * from %s)" to stdout WITH CSV HEADER | psql -d remote_db | gzip > ./%s/%s.gz"""%(table_name,dir_name,file_name) os.system(cmd) I would like to not use CSV if possible, as I lose the field types and the encoding can get messed up. First best would probably be some way of getting the generating SQL code for the table using \copy. Next best would be XML, ideally with some way of preserving the field types. If that doesn't work, I think the final option might be two queries---one to get the field data types, the other to get the actual data. Any thoughts or advice would be greatly appreciated - thanks!

    Read the article

< Previous Page | 42 43 44 45 46 47 48 49 50 51 52 53  | Next Page >