  • Exceptional slowdown of robocopy copying from VM to DFS array

    - by user1588867
    I've got an old win 2003 VM (VMware) on a blade cluster of VMs that I'm moving a considerable amount of files to our new DFS array. There are two main folders with about 1.7 million and half a million smaller files (letters, memos, and other smaller files) respectively. Total size is ~420 GB and ~100 GB. We're using the gui version of robocopy on the server to copy the files. We had initiated a file copy about a month ago to test the process and found that it was taking around 4 hours for the large file. Now that I'm in the process of actually switching the files over it has been taking 18-20 hours. Nothing has changed on the server side and nothing has changed on the settings of the copy (no logs, 1 retry with a wait of 1 second). Our intent is to shut off the share and force the copy over again to get all the files that have been left out of the copy due to being locked by users. I can't take a 20 hour outage to do that though. Does anyone have any theories about what could be causing such a delay for robocopy compared to previously shorter runs?

    Read the article

  • DNS manager in Windows Server 2012 Essentials - My one server appears twice

    - by tetranz
    I have a newly installed Windows Server 2012 Essentials. It works pretty good although I'm working on some DNS improvements. Something that seems a little weird is in DNS Manager, my server appears twice. Once as hostname and once as hostname.mydomain.local. They seem to be identical and locked in sync. If I change one, the other follows. Is this normal? Does anyone know why I have this? I'm talking about the top level on the navigation. The very top is DNS and then these two below. Zones, forwarders etc are below them. I've found a couple of forum posts of people asking the same thing but no useful answer. All tutorials etc I can find with screenshots show only one which makes me uncomfortable. The server was installed out of the box as standard with the wizards. I know about the recommendation not to use .local but the wizards didn't give me any other option.

    Read the article

  • How does one debug Windows network share authentication?

    - by ajs410
    I have machine0 with 32-bit Vista, logged in as a domain user, running a VMWare image of 32-bit Vista, logged in as a local user, with the VM set to bridge the network. From an administrator account (called admin) within the VM, I try to access the hidden C$ share on machine0 (i.e. start - run - "\\machine0\C$\"). I get no prompts for credentials. Worse, machine0 has an admin account (different password), and machine0\admin gets locked out when VM\admin tries to access the network share. I get a message several seconds later, which feels like a cached credential failure leading to the lockout. I have checked several places for cached credentials; net use, Stored Usernames and Passwords, mapped shares. I rebooted (both machine0 and VM) to make sure the session was clear of any cached credentials. I can force net use to use my domain credentials when accessing machine0, and then I can see the share. I can also see shares that do not require credentials. I decided to try another machine on the network (machine1), 64-bit Vista, local user. This machine has no lockout policy, and after several seconds (feels like failed cached credentials again) it prompts me for credentials. After I enter them, it re-prompts me, saying "logon unsuccessful" (tried my domain credentials, and also machine1\admin's). Which is bogus, because I proceed to log on with remote desktop using the machine1\admin credentials. I have tried this on another machine (machine2, 64-bit Vista), running a copy of the same 32-bit VM, and I don't remember having this problem. machine0 has a fingerprint reader...could that try storing passwords and interfere? Are there any places I'm missing where there could be cached credentials? Is there a way to see what credentials are flying around when I try to connect?

    Read the article

  • Half of installed RAM is hardware reserved

    - by user968270
    After a rather arduous and convoluted series of problems that left me without a desktop for ~80 days, I've finally got the thing up and running, having replaced the power supply, motherboard, graphics card and CPU. Now, however, I'm experiencing the 'hardware reserved RAM' issue. Perhaps this is the exhaustion talking, but looking at the question that tends to get pointed to when this kind of topic gets locked as a duplicate hasn't helped. I have 16 GB of RAM installed in an MSi 970A-G46, which is spec'd for up to 32 GB of RAM. The BIOS recognizes that I have 16 GB installed, and the resource monitor also shows the whole 16 GB, only it shows 8 GB as hardware reserved. I've seen suggestions that it's an OS issue, but the particular installation of Windows 7 (64-bit) which I'm running on my boot drive is the same as the one that could actually access the 16 GB in my previous motherboard (MSi 870A-G54). I've updated my BIOS using the MSi Live Update tool and restarted the machine with no effect, and I cannot seem to locate any 'Memory Remapping' option as I've seen mentioned. I've physically swapped the RAM between the slots to no effect. I've unchecked the Maximum Memory box in the msconfig Boot tab's advanced options, also to no effect. These are my system's basic specifications OS: Windows 7 Home Premium (64-Bit) Motherboard: MSi 970A-G46 CPU: AMD FX-8150 Graphics Card: XFX Radeon HD 6870 Boot Drive: OCZ Agility 3 Storage Drive: Samsung Spinpoint F3 ST1000DM005/HD103SJ 1TB PSU: Thermaltake TR-2 TR600 600W ATX12V v2.3

    Read the article

  • Diagnosing Random Network Lag

    - by uesp
    I'm having trouble diagnosing some random lag on a 6 server LAMP cluster serving a MediaWiki site. While we're serving some 100 pages/sec the servers themselves are running fine with less than 0.5 load, no locked processes, no paging, no errors being logged, etc.... Lag is present on all servers and is random: one minute its fine the next it's there. DNS lookups on the servers are randomly slow. For example time nslookup google.com varies randomly from a few milliseconds to several seconds and sometimes times out entirely. While we use IP addresses internally on the cluster this may be a symptom of the root issue. We are not running our own DNS server. The Apache server-status pages randomly lag or time out. Benchmarking using ab between servers shows a few loads sometimes take 3000 ms (almost exactly). Benchmarking server-status on the local server itself usually shows no issue (it showed a lag only once among a few hundred tests). The servers are sitting behind a switch and a firewall which I don't have any access to so I don't know their setup or status. While we are under heavier than normal load a 2 Mbps incoming and 20 Mbps outgoing traffic shouldn't be stressing the switch or firewall should it? My feeling is that it is the switch/firewall or something above them in the ISP like their DNS but can't confirm it. I need some other tests or methods of diagnosing this lag to try and narrow down the ultimate cause.

    Read the article

  • Joomla performance problems on AWS

    - by Bobby Jack
    I'm running a site on AWS with the following setup: Single m1.small instance (web server) Single RDS m1.small db Joomla 1.5 Generally, the site is performant, but is fairly low-traffic - say around 50-100 visits / hour. However, at peak time, we see about double that traffic. During peak time, pretty much every day: CPU usage on the web server slowly climbs to 100% CPU usage on the RDS server climbs quite quickly to about 30%, from an average of about 15 Database connections shoot up to about 140, from a normal average of about 2 or 3 The site is then occasionally unreachable, certainly according to pingdom monitoring. Does anyone recognise this behaviour? Can you point me in the right direction to begin investigating? Of course, RDS makes it difficult to do things like slow query logging, so I've started by regularly dumping the mysql process list into a file to see if there's anything I can spot there, but it would be good to have something more concrete to investigate. UPDATE At least, can someone confirm that I'm definitely right in saying that the level of traffic implies the problem must be a specific type of query taking way longer than it should to execute? This would happen if a table gets locked, and many queries need to write to it, right? For this very reason, I've already changed the __session table type to InnoDB.

    Read the article

  • Changing the View of a Folder When It Is Opened from Finder

    - by user60044
    When I was running OS 10.4 I had all my folders beautifully organized with position and which ones should be opened in View mode and which one in Icon, etc. When I transitioned to 10.6 I found that OS ignored all that information and imposes an awful consequence of changing the view for some folder and that view moving up to all parent folders which don't have their views locked. The only way I can think of to get this functionality back is to either write a program that given a root directory will enumerate it setting the views based upon a static template I have. The other way I thought I could accomplish this is by Folder Actions. Aside from the fact that I don't know AppleScript it seems folder actions cannot be inherited. Since I have 1000s of folders involved here, all being inherited from a single root, I could not possibly manually add that action to each of those folders. What I would like to have is a folder action that whenever I open the folder from Finder, then if it contains any JPG, GIF, etc. type image files that it will automatically open that folder with a view of Icon with a reasonable size to support the number of images. If the folder contains only folders, then to open that folder in the list view. Does anyone have anything that could do this for me? Thank You, -- Mark

    Read the article

  • SQL Server log backups “stalling”

    - by MattK
    I have interited a box running SQL Server 2008 and Windows 2003, and have had a few events where largeish (35GB) log backups "stall", both before and after the installation of SQL 2008 SP1. The server log ships to a standby, so regular log backups are taken at 15 minute intervals. However, after an index reorg causes the log to grow to about 35GB (on a DB with about 17GB of data), the next log backup runs to ~95% completion, then seems to stop. The process shows as suspended, with a wait state of BACKUPIO. CPU, read, and write activity on the SPID also does not change, and the process stays in this state for hours, when normally a backup of this size should complete in about 20 minutes. This server has a single RAID-1 volume, thus the source database files and destination backup files are on the same volume. However, I cannot determine if another process is blocking the backup. The backup SPID cannot be killed, and the only way to terminate the log backup and clear the lock on the backup file is to cycle the SQL Server service. There was one event where the backup terminated completely, with an error that another process had locked the backup file, but no details about what that process was. Can anyone suggest a cause or diagnostic process to this situation?

    Read the article

  • Windows 8 preinstall downgrade to Win 7: UEFI problems :/

    - by Tim Flemming
    I have a friend who has a Hp Laptop with UEFI booting. He locked himself out of windows 8 (forgot his password)... so he called me. Well after trying to use the latest version of chntpw in UBCD5.2.6, i came to the conclusion i needed to wipe the drive and install windows 7. A little googling suggested using certain versions of chntpw, but i decided to not waste the time burning endless CDs. Anyway, He agreed to installing Win7 "I hate the big tile thingys". So i attacked with Gparted. Wiped the whole drive. Set flags to boot. Set part table as MBR. However upon trying to install win7, it still claimed i had a GPT style disk. unable to install. the only thing i can think of I'm doing wrong is not changing the bios/UEFI to legacy... My question is, If I enable legacy, somehow get the drive to actually be MBR, and use my X86 DVD, should I be good? Is there some common glitches ppl miss when dealing with GPT/EFI/UEFI? I need answers cuz he now has a blank laptop which I am responsible for. Another question. windows 8 came installed on a GPT disk. SO WHY WHEN I BOOT THE INSTALL DVD DOES IT SAY IT CANT INSTALL TO A GPT STYLE DISK??? WTF??? talk about the bleeding edge man.

    Read the article

  • windows 2008 r2 iis worker proccess memory usage increase

    - by nLL
    I have this web site written in c#. around 400-500 users online at any time. it was on windows 2008 32 bit machine before and never ever locked/slowed down due to increased memory consumption up until i upgraded it's server to win 2008 r2 64 bit. Old server had only 4 gig ram and quad core cpu at 2ghz. site was working just fine. since i've upgraded the server i noticed (2 times with in 10 days) it started to eat ram. last night it went up to 4 gb ram. with ram increase response slows down quite a lot. recycling app pool doesn't help. I have to restart it's worker process to recover. i've noticed this usually happens if there are continuous errors. as i didn't change anything in the code am i safe to assume it is not related to memory leak in the code? did anyone came across something like that? same thing happens if i create continuous errors with classic asp. thanks

    Read the article

  • The BitLocker encrypted logical drive of my laptop is not accessible. On clicking error appears,"Application not found"

    - by Nauman Khan
    I had an important personal data that was stored in my laptop drive 'F'. My 4 year old son also uses my laptop to play games. To secure my data I used bitlocker software that was already there in my windows 7 ultimate 32 bit. I am using a Dell D 630 Core2Duo laptop. The thing worked fine for me and I have been able to access my data in drive 'F' as and when I required. But today, when I tried to open my 'F' drive, an error box appeared saying "Application not found". I right clicked and checked 'properties' of 'F' drive. It showed me Used Space = 0 bytes and Free Space = 0 bytes. I opened 'Disk Management' which showed my 'F' drive file system as 'Unknown (Bitlocker Encrypted). 'Disk Management' is also showing my 'F' drive as healthy logical drive. I opened 'Manage bitlocker' and found that my 'F' drive was being shown locked and 'Unlock Drive' was displayed against it, however, when i click on 'Unlock Drive', it does not function. I opened 'TPM Administration' and found an information that 'Compatible TPM cannot be found'. My bitlocker encryption was working fine which means that I had a compatible TPM in my laptop. Where has it gone? How can I enable it? Is my 'F' Drive lost forever and thus the data in there as well?

    Read the article

  • Strange WiFi problem - network is "not connected" but works

    - by GalacticCowboy
    Background I'm using a Windows XP tablet PC connected to my home network. I do broadcast the SSID, but otherwise the wireless network is locked down as tight as I can make it - WPA2 with a strong key, MAC filtering, etc. I've had this computer for about 4 years and the router for about 6 months. Before that, the previous router was set up in the same way, and I've never had any particular problems. Problem This morning - as I type this, as a matter of fact - Windows is reporting that none of my network connections are connected. Yet somehow my Internet connectivity still works! ipconfig reports a valid IP address, domain, etc., even though Windows apparently doesn't know about it. I tried repairing the connection and it had no effect - the repair eventually timed out. I'm pretty sure that I could reboot the computer and/or the router, etc. and it would fix the problem. However, I'm more interested in knowing if any of you have ever seen anything like this, and what might have caused it? Since it works I'm not inclined to mess with it too much. My concern is that it's a precursor to bigger problems.

    Read the article

  • Allow outgoing connections for DNS

    - by Jimmy
    I'm new to IPtables, but I am trying to setup a secure server to host a website and allow SSH. This is what I have so far: #!/bin/sh i=/sbin/iptables # Flush all rules $i -F $i -X # Setup default filter policy $i -P INPUT DROP $i -P OUTPUT DROP $i -P FORWARD DROP # Respond to ping requests $i -A INPUT -p icmp --icmp-type any -j ACCEPT # Force SYN checks $i -A INPUT -p tcp ! --syn -m state --state NEW -j DROP # Drop all fragments $i -A INPUT -f -j DROP # Drop XMAS packets $i -A INPUT -p tcp --tcp-flags ALL ALL -j DROP # Drop NULL packets $i -A INPUT -p tcp --tcp-flags ALL NONE -j DROP # Stateful inspection $i -A INPUT -m state --state NEW -p tcp --dport 22 -j ACCEPT # Allow established connections $i -A INPUT -m state --state ESTABLISHED,RELATED -j ACCEPT # Allow unlimited traffic on loopback $i -A INPUT -i lo -j ACCEPT $i -A OUTPUT -o lo -j ACCEPT # Open nginx $i -A INPUT -p tcp --dport 443 -j ACCEPT $i -A INPUT -p tcp --dport 80 -j ACCEPT # Open SSH $i -A INPUT -p tcp --dport 22 -j ACCEPT However I've locked down my outgoing connections and it means I can't resolve any DNS. How do I allow that? Also, any other feedback is appreciated. James

    Read the article

  • Strange boot problems on 6 month old setup

    - by Balefire
    I've already exhausted my knowledge on this one, so forgive me if this post is a bit long. I built a computer 6 months ago for my wife and it worked fine until last week. Then it randomly shut down and would lock up while trying to boot on the boot screen. I cleared cmos and it allowed me to do startup recovery, but it "failed to fix the issue" so I reinstalled windows on the HD (moving the old install to windows_old). It worked, so I started installing drivers again, but then when I restarted to finalize installations it locked up again. This time, I took the hard drive and hooked it up to my computer, backed up all her files, and then formatted the hard drive before reinstalling it. (again had to clear cmos to let me boot from disk) It installed windows, I installed drivers, and it worked for a few hours but then died during startup again. So, then I got a new HD, cleared cmos, and installed clean again, with the same result as the time before, it worked for a few hours, installed windows updates, then crashed on the 3rd or 4th time turning it on. I decided next to try reinstalling and then going online to see if there were any updates for the BIOS or drivers on the Motherboard, but now I can't get it to even bring up the boot menu, so now I'm just left wondering was it the motherboard, or is it the CPU, or the RAM? The problem was strangely intermittent so I thought it had to be a software issue, since a hardware issue would ALWAYS fail to boot, right? But now it seems to be a hardware issue, because it's not bringing up anything. Any suggestions? System: Windows 7 64-bit 970A-DS3 Gigabyte Motherboard AMD Phenom II X4 955 Deneb 3.2GHz Quad core Proc GeForce GT 430 (Fermi) 1GB Video Card 500W PSU 2 x G.SKILL Ripjaws X Series 4GB 240-Pin DDR3 1600 RAM

    Read the article

  • Svchost.exe connecting to different IPs with remote port 445

    - by Coll911
    Im using Windows XP Professional SP2. Whenever I start my Windows, svchost.exe starts connecting to all the possible IPs on LAN like from 192.168.1.2 to 192.168.1.200. The local port ranges from 1000-1099 and the remote port being 445. After it's done with the local IPs, it starts connecting to other random IPs. I tried blocking connections to the port 445 using the local security polices but it didn't work. Is there any possible way I could prevent svchost from connecting to these IPs without involving any firewall installed? My PC slows down due to the load. I scanned my PC with MalwareBytes and found out it was infected with a worm, it's deleted now but still svchost is connecting to the IPs. I also found out that in my Windows Firewall settings, under Internet Control Message Protocol (ICMP), there's a tick on "allow incoming echo request" (usually disabled) which is locked and I can't disable it. Its description is as follows Messages sent to this computer will be repeated back to the sender. This is used for trouble shooting for e.g to ping a machine. Requests of this type are automatically allowed if TCP port 445 is enabled. Any solutions? I can't bear going with the reinstalling Windows phase again.

    Read the article

  • Windows 7 pc freezes for an indeterminate amount of time after unlocking

    - by pikes
    Not sure if this type of question is appropriate for this forum, but I've tried everything I can think of to solve this problem aside from format/reinstall. I recently got a new work PC (Dell optiplex 755) with windows 7 professional x64. Standard developer software installed for .net development: VS2008, VS2005, SQL management studio, office 2007, etc. Recently I've been having this weird problem where after I lock my pc, when I try to unlock it, the screen will be black for awhile after unlocking. I can ctl+alt+del and put my password in but then it just goes black. The amount of time on the black screen seems to be related to the amount of time I am away from my PC. If only away a few minutes, it'll take about a minute to get to the desktop. If away for an hour, could take up to 15 minutes. If I lock it and go home for the night, I have to restart my PC in the morning (I've let it sit for an hour after a night of being locked and nothing happened). It doesn't do it every time but definitely the majority of the time. One weird thing I've seen is that if I remote into my machine before trying to log back in it does not do it. I uninstalled all software back to the point when I remember it started happening and it still does it. I was using this PC for a few weeks without this problem happening at all. Anyone know what my next troubleshooting steps could be? My IT department tried to fix it by moving my old profile to another disk and having me log in, effectively recreating a profile from scratch but that didn't solve it. As I said above if this isn't the right forum for these types of questions please let me know. Thanks in advance!

    Read the article

  • Hosting options for data-enabled web application

    - by Hertfordian
    I am independently developing an asp.net business application with a MySQL database. I currently have a Windows web hosting account which includes MySQL and MS SQL as installed supported options. I am not yet finally committed to using MySQL and I want to keep my options open to evaluate MS SQL and possibly other options such as PostGreSQL later when more of the business logic is in place - my data access layer will handle the database connectivity. The web hosting setup I have now is fine for development purposes, but if in future I want to use, say, PostGreSQL Server, and a level of usage of, say, 10,000 hits per day concentrated in business hours, I'm assuming I'll need a dedicated server. But in that case, should I just install PostGreSQL on the dedicated server, or is best practice to have a separate database server - perhaps locked down so that it can only be accessed through the web server? And supposing it was only 2000 hits a day - how would that change things? I'd appreciate it if anyone could point me in the direction of a useful guide to these sorts of issues. Naturally if I start paying for separate servers, I would like to know exactly why I'm doing it and what the performance issues and thresholds are.

    Read the article

  • How to find Stolen MacBook with iCloud

    - by user1518089
    My MacBook Air was stolen about 6 weeks ago. Through iCloud and "Find Phone", I have some pictures and a location down to about 2 blocks. The pictures are from the current user taking photos which automatically appear on my local devices. (Yes they probably saw my pictures until I stopped taking them. Yes, they are stupid.) I was thinking about going there and hanging out until I recognized the current users, but it is in a very bad neighborhood and I would be noticed. The police have not done anything. Yes, the MacBook can be locked or a message sent. I am hoping to get it back. Does anyone have ideas on how to track them down? While Find Phone shows their location, it does not report an ip address. Is there a way to get an ip address? Does Facebook face recognition work on strangers? Come on tech geniuses, help me play detective. It does not have Drop Box installed.

    Read the article

  • Rsync root files between systems without specifying password

    - by xpt
    This seems very tricky to me. I've set up my two systems so that I can rsync files between them as me, without specifying password. Now the the problem is to rsync files that belong to root. On both of my systems, there are no root passwords. The only way to become root is via sudo. So I can neither give a password for sudo rsyn local root@remote:, no use my ssh-agent to supply pass phrase. I don't want to set up a root password on any systems; and I do need the files to be owned by root on both systems. EDIT: Using the files that belong to root is just an example, I need a way for my unprivileged account to read/write system (including root-owned) files easily. One example is to copy my configured /root environment into the freshly-installed system. The two systems are actually two VMs under a single host, so it's not a big concern for me to copy root-owned files between them. EDIT 2: If I only want to copy my configured /root environment into the freshly-installed system, I can use tar: sudo tar cvzf - /root | ssh me@remote sudo tar xvzf - -C / But I do need rsync to update from time to time. Any easy way to make it happen? EDIT 3: Formally formulate the question Alright, it all began with the question, how to rsync files that belong to root between two systems as a normal unprivileged user, without specifying password, under the condition that, The root account is locked on both of systems. I.e., there are no root passwords. The only way to become root is via sudo (recommended security practice, see http://help.ubuntu.com/community/RootSudo) I don't want a completely passwordless sudo but don’t want to be typing passwords all the time either. The normal unprivileged user has entered their ssh pass phrase into the ssh agent. Thanks

    Read the article

  • Windows 7 VM log on lockout

    - by AKa
    My Windows 7 XP Mode virtual machine has just locked me out of password log on. Two years of use and it never required I use a password on wake up, I never asked for that. Suddenly yesterday, password required! I located password and used it successfully a couple of times, but now even that is not good enough! Perhaps (unfairly) because I tried to get to the bottom of the new phenomenon and removed the password from the user accounts? Permissions are still set to ok for all users. I have been all the way through the settings I can access with the VM file hibernated, and have deleted the previously saved log on info, which always previously worked automatically as charged. Now when I attempt to log on it asks me for credentials, seems like progress, but when I offer them, and check the "remember my credentials" box, I still get the splash screen "The system could not log you on. [reminder about caps...]" !! Round and round. Back up and restore point versions of the VM toss me back into the same log on loop. There are no other machines on any network, I am the administrator and sole user. It must be specifically about the log on, a speck of dust corruption ... is there a way around this? I tried creating a new VM but the black inner box gets stuck at one point requesting I insert a boot disc. Thanks for input, AKa

    Read the article

  • USB Drive that simultaneously connects to more than one computer

    - by user2499
    Background: I have a portable USB drive that I use to make sure I have access to common files whenever at home, work, travel etc for cases when I may not have Internet/Network access of any kind. There are some cases when I have to work simultaneously on a laptop and a desktop computer, and for those cases I usually have to unplug this USB hard drive and move it between the two. Question: dual-computer USB drive? Is there a USB-based solution that would enable me to use this portable drive between two computers simultaneously? If there is not a USB-based solution, does anyone have alternative suggestions, consistent with the underlying rationale? Rationale: Sometimes I have to work on a desktop computer with locked-down networking capabilities (such as at the local photocopy shop) and it can be difficult to get a network configuration that allows dual-computer access without breaking things, or accidentally making my USB drive visible to the entire network. Basically what I need is a very simply LAN that is guaranteed to work regardless of the rules or constraints set by the network administrator for wherever I happen to be at the time. See also: http://superuser.com/questions/99274/how-to-connect-two-computers-with-usb

    Read the article

  • Methods and practices for managing a network that has no internet connection

    - by FaultyJuggler
    Originally asked in Super User but realized this belongs here. Long story short, I am setting up a network with 32 servers of varying specs that will be used for testing and development. We will be using RedHat Linux, we also do not have a router as of yet and were looking into making one of the servers act as our router/DHCP etc. The small cluster will be on an isolated network with no internet. I can use external harddrives and discs to transfer anything from external sources into machines on the network, so this isn't a locked down secure network, it just won't have a direct connection to the outside world. I've worked on such setups before, but always long after they were setup. So I'm reaching out to see what everyone knows as far as how groups have handled initial setup and maintenance of such a situation. What is the best way to get them all configured and up to date? What are the best ways to automate updates, network wide installs, etc. With the only given that I have large multi-terabyte external hard drives that would be used to drop whatever files are needed onto a central server, how do i then distribute those files and install their contents? I've done perl scripting, some teammates have played with puppet, so we aren't completely in the dark, I just wanted to avoid reinventing the wheel since this is a common challenge.

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • How do NTP Servers Manage to Stay so Accurate?

    - by Akemi Iwaya
    Many of us have had the occasional problem with our computers and other devices retaining accurate time settings, but a quick sync with an NTP server makes all well again. But if our own devices can lose accuracy, how do NTP servers manage to stay so accurate? Today’s Question & Answer session comes to us courtesy of SuperUser—a subdivision of Stack Exchange, a community-driven grouping of Q&A web sites. Photo courtesy of LEOL30 (Flickr). The Question SuperUser reader Frank Thornton wants to know how NTP servers are able to remain so accurate: I have noticed that on my servers and other machines, the clocks always drift so that they have to sync up to remain accurate. How do the NTP server clocks keep from drifting and always remain so accurate? How do the NTP servers manage to remain so accurate? The Answer SuperUser contributor Michael Kjorling has the answer for us: NTP servers rely on highly accurate clocks for precision timekeeping. A common time source for central NTP servers are atomic clocks, or GPS receivers (remember that GPS satellites have atomic clocks onboard). These clocks are defined as accurate since they provide a highly exact time reference. There is nothing magical about GPS or atomic clocks that make them tell you exactly what time it is. Because of how atomic clocks work, they are simply very good at, having once been told what time it is, keeping accurate time (since the second is defined in terms of atomic effects). In fact, it is worth noting that GPS time is distinct from the UTC that we are more used to seeing. These atomic clocks are in turn synchronized against International Atomic Time or TAI in order to not only accurately tell the passage of time, but also the time. Once you have an exact time on one system connected to a network like the Internet, it is a matter of protocol engineering enabling transfer of precise times between hosts over an unreliable network. In this regard a Stratum 2 (or farther from the actual time source) NTP server is no different from your desktop system syncing against a set of NTP servers. By the time you have a few accurate times (as obtained from NTP servers or elsewhere) and know the rate of advancement of your local clock (which is easy to determine), you can calculate your local clock’s drift rate relative to the “believed accurate” passage of time. Once locked in, this value can then be used to continuously adjust the local clock to make it report values very close to the accurate passage of time, even if the local real-time clock itself is highly inaccurate. As long as your local clock is not highly erratic, this should allow keeping accurate time for some time even if your upstream time source becomes unavailable for any reason. Some NTP client implementations (probably most ntpd daemon or system service implementations) do this, and others (like ntpd’s companion ntpdate which simply sets the clock once) do not. This is commonly referred to as a drift file because it persistently stores a measure of clock drift, but strictly speaking it does not have to be stored as a specific file on disk. In NTP, Stratum 0 is by definition an accurate time source. Stratum 1 is a system that uses a Stratum 0 time source as its time source (and is thus slightly less accurate than the Stratum 0 time source). Stratum 2 again is slightly less accurate than Stratum 1 because it is syncing its time against the Stratum 1 source and so on. In practice, this loss of accuracy is so small that it is completely negligible in all but the most extreme of cases. Have something to add to the explanation? Sound off in the comments. Want to read more answers from other tech-savvy Stack Exchange users? Check out the full discussion thread here.

    Read the article

  • Stuck due to "knowing too much"

    - by Ran Biron
    Note more discussion at http://news.ycombinator.com/item?id=4037794 Welcome Hacker News Visitors! While HN is a fine forum for discussion and debate, Programmers - Stack Exchange is not. From the FAQ: If your motivation for asking the question is “I would like to participate in a discussion about ____”, then you should not be asking here. However, if your motivation is “I would like others to explain ____ to me”, then you are probably OK. (Discussions are of course welcome in our real time web chat.) Currently, this question is viewed by the membership of Programmers.SE as more likely to provoke unproductive discussion than constructive answers; while debates on its form and future are conducted, it will be locked to prevent arguments and vandalism. -- Shog9 I have a relatively simple development task, but every time I try to attack it, I end up spiraling in deep thoughts - how could it extending the future, what are the 2nd generation clients going to need, how does it affect "non functional" aspects (e.g. Performance, authorization...), how would it best be architectured to allow change... I remember myself a while ago, younger and, perhaps, more eager. The "me" I was then wouldn't have given a thought about all that - he would've gone ahead and wrote something, then rewrote it, then rewrote it again (and again...). The "me" today is more hesitant, more careful. I find it much easier today to sit and plan and instruct other people on how to do things than to actually go ahead and do them myself - not because I don't like to code - the opposite, I love to! - but because every time I sit at the keyboard, I end up in that same annoying place. Is this wrong? Is this a natural evolution, or did I drive myself into a rut? Fair disclosure - in the past I was a developer, today my job title is a "system architect". Good luck figuring what it means - but that's the title. Wow. I honestly didn't expect this question to generate that many responses. I'll try to sum it up. Reasons: Analysis paralysis / Over engineering / gold plating / (any other "too much thinking up-front can hurt you"). Too much experience for the given task. Not focusing on what's important. Not enough experience (and realizing that). Solutions (not matched to reasons): Testing first. Start coding (+ for fun) One to throw away (+ one API to throw away). Set time constraints. Strip away the fluff, stay with the stuff. Make flexible code (kinda opposite to "one to throw away", no?). Thanks to everyone - I think the major benefit here was to realize that I'm not alone in this experience. I have, actually, already started coding and some of the too-big things have fallen off, naturally. Since this question is closed, I'll accept the answer with most votes as of today. When/if it changes - I'll try to follow.