Search Results

Search found 6706 results on 269 pages for 'power supply'.

Page 47/269 | < Previous Page | 43 44 45 46 47 48 49 50 51 52 53 54  | Next Page >

  • In 10.10, USB 3.0 PCI Express card recognized by lspci but not lsusb or dmesg. How to fix?

    - by Paul
    Asus N PC, runs 10.10 x86_64 The Asus N comes with 4 usb 2.0 ports, each labelled 2.0 on the case. Attempting to add two usb 3.0 ports to be provided by a generic usb 3.0 pci express card installed in the pci expres slot. The new card says usb 3.0 and has the blue ports. The card is installed into the laptop unpowered, then the laptop is powered on and boots normally. Nothing happens when a USB 3.0 flash drive is inserted into the usb 3.0 port. uname -a Linux drpaulbrewer-N90SV 2.6.35.8 #1 SMP Fri Jan 14 15:54:11 EST 2011 x86_64 GNU/Linux lspci -v 00:00.0 Host bridge: Silicon Integrated Systems [SiS] 671MX Subsystem: ASUSTeK Computer Inc. Device 1b27 Flags: bus master, medium devsel, latency 64 Kernel modules: sis-agp 00:01.0 PCI bridge: Silicon Integrated Systems [SiS] PCI-to-PCI bridge (prog-if 00 [Normal decode]) Flags: bus master, fast devsel, latency 0 Bus: primary=00, secondary=01, subordinate=01, sec-latency=0 I/O behind bridge: 0000d000-0000dfff Memory behind bridge: fa000000-fdefffff Prefetchable memory behind bridge: 00000000d0000000-00000000dfffffff Capabilities: [d0] Express Root Port (Slot+), MSI 00 Capabilities: [a0] MSI: Enable+ Count=1/1 Maskable- 64bit- Capabilities: [f4] Power Management version 2 Capabilities: [70] Subsystem: Silicon Integrated Systems [SiS] PCI-to-PCI bridge Kernel driver in use: pcieport 00:02.0 ISA bridge: Silicon Integrated Systems [SiS] SiS968 [MuTIOL Media IO] (rev 01) Flags: bus master, medium devsel, latency 0 00:02.5 IDE interface: Silicon Integrated Systems [SiS] 5513 [IDE] (rev 01) (prog-if 80 [Master]) Subsystem: ASUSTeK Computer Inc. Device 1b27 Flags: bus master, medium devsel, latency 128 I/O ports at 01f0 [size=8] I/O ports at 03f4 [size=1] I/O ports at 0170 [size=8] I/O ports at 0374 [size=1] I/O ports at ffe0 [size=16] Capabilities: [58] Power Management version 2 Kernel driver in use: pata_sis 00:03.0 USB Controller: Silicon Integrated Systems [SiS] USB 1.1 Controller (rev 0f) (prog-if 10 [OHCI]) Subsystem: ASUSTeK Computer Inc. Device 1b27 Flags: bus master, medium devsel, latency 64, IRQ 20 Memory at f9fff000 (32-bit, non-prefetchable) [size=4K] Kernel driver in use: ohci_hcd 00:03.1 USB Controller: Silicon Integrated Systems [SiS] USB 1.1 Controller (rev 0f) (prog-if 10 [OHCI]) Subsystem: ASUSTeK Computer Inc. Device 1b27 Flags: bus master, medium devsel, latency 64, IRQ 21 Memory at f9ffe000 (32-bit, non-prefetchable) [size=4K] Kernel driver in use: ohci_hcd 00:03.3 USB Controller: Silicon Integrated Systems [SiS] USB 2.0 Controller (prog-if 20 [EHCI]) Subsystem: ASUSTeK Computer Inc. Device 1b27 Flags: bus master, medium devsel, latency 64, IRQ 22 Memory at f9ffd000 (32-bit, non-prefetchable) [size=4K] Capabilities: [50] Power Management version 2 Kernel driver in use: ehci_hcd 00:04.0 Ethernet controller: Silicon Integrated Systems [SiS] 191 Gigabit Ethernet Adapter (rev 02) Subsystem: ASUSTeK Computer Inc. Device 11f5 Flags: bus master, medium devsel, latency 0, IRQ 19 Memory at f9ffcc00 (32-bit, non-prefetchable) [size=128] I/O ports at cc00 [size=128] Capabilities: [40] Power Management version 2 Kernel driver in use: sis190 Kernel modules: sis190 00:05.0 IDE interface: Silicon Integrated Systems [SiS] SATA Controller / IDE mode (rev 03) (prog-if 8f [Master SecP SecO PriP PriO]) Subsystem: ASUSTeK Computer Inc. Device 1b27 Flags: bus master, medium devsel, latency 64, IRQ 17 I/O ports at c800 [size=8] I/O ports at c400 [size=4] I/O ports at c000 [size=8] I/O ports at bc00 [size=4] I/O ports at b800 [size=16] I/O ports at b400 [size=128] Capabilities: [58] Power Management version 2 Kernel driver in use: sata_sis Kernel modules: sata_sis 00:06.0 PCI bridge: Silicon Integrated Systems [SiS] PCI-to-PCI bridge (prog-if 00 [Normal decode]) Flags: bus master, fast devsel, latency 0 Bus: primary=00, secondary=02, subordinate=02, sec-latency=0 Memory behind bridge: fdf00000-fdffffff Capabilities: [b0] Subsystem: Silicon Integrated Systems [SiS] Device 0004 Capabilities: [c0] MSI: Enable+ Count=1/1 Maskable- 64bit+ Capabilities: [d0] Express Root Port (Slot+), MSI 00 Capabilities: [f4] Power Management version 2 Kernel driver in use: pcieport 00:07.0 PCI bridge: Silicon Integrated Systems [SiS] PCI-to-PCI bridge (prog-if 00 [Normal decode]) Flags: bus master, fast devsel, latency 0 Bus: primary=00, secondary=03, subordinate=06, sec-latency=0 I/O behind bridge: 0000e000-0000efff Memory behind bridge: fe000000-febfffff Prefetchable memory behind bridge: 00000000f6000000-00000000f8ffffff Capabilities: [b0] Subsystem: Silicon Integrated Systems [SiS] Device 0004 Capabilities: [c0] MSI: Enable+ Count=1/1 Maskable- 64bit+ Capabilities: [d0] Express Root Port (Slot+), MSI 00 Capabilities: [f4] Power Management version 2 Kernel driver in use: pcieport 00:0f.0 Audio device: Silicon Integrated Systems [SiS] Azalia Audio Controller Subsystem: ASUSTeK Computer Inc. Device 17b3 Flags: bus master, medium devsel, latency 0, IRQ 18 Memory at f9ff4000 (32-bit, non-prefetchable) [size=16K] Capabilities: [50] Power Management version 2 Kernel driver in use: HDA Intel Kernel modules: snd-hda-intel 01:00.0 VGA compatible controller: nVidia Corporation G96 [GeForce GT 130M] (rev a1) (prog-if 00 [VGA controller]) Subsystem: ASUSTeK Computer Inc. Device 2021 Flags: bus master, fast devsel, latency 0, IRQ 16 Memory at fc000000 (32-bit, non-prefetchable) [size=16M] Memory at d0000000 (64-bit, prefetchable) [size=256M] Memory at fa000000 (64-bit, non-prefetchable) [size=32M] I/O ports at dc00 [size=128] [virtual] Expansion ROM at fde80000 [disabled] [size=512K] Capabilities: [60] Power Management version 3 Capabilities: [68] MSI: Enable- Count=1/1 Maskable- 64bit+ Capabilities: [78] Express Endpoint, MSI 00 Capabilities: [b4] Vendor Specific Information: Len=14 <?> Kernel driver in use: nvidia Kernel modules: nvidia-current, nouveau, nvidiafb 02:00.0 Network controller: Atheros Communications Inc. AR928X Wireless Network Adapter (PCI-Express) (rev 01) Subsystem: Device 1a3b:1067 Flags: bus master, fast devsel, latency 0, IRQ 16 Memory at fdff0000 (64-bit, non-prefetchable) [size=64K] Capabilities: [40] Power Management version 2 Capabilities: [50] MSI: Enable- Count=1/1 Maskable- 64bit- Capabilities: [60] Express Legacy Endpoint, MSI 00 Capabilities: [90] MSI-X: Enable- Count=1 Masked- Kernel driver in use: ath9k Kernel modules: ath9k 03:00.0 USB Controller: NEC Corporation uPD720200 USB 3.0 Host Controller (rev 03) (prog-if 30) Flags: bus master, fast devsel, latency 0, IRQ 10 Memory at febfe000 (64-bit, non-prefetchable) [size=8K] Capabilities: [50] Power Management version 3 Capabilities: [70] MSI: Enable- Count=1/8 Maskable- 64bit+ Capabilities: [90] MSI-X: Enable- Count=8 Masked- Capabilities: [a0] Express Endpoint, MSI 00 lsusb Bus 003 Device 002: ID 0b05:1751 ASUSTek Computer, Inc. BT-253 Bluetooth Adapter Bus 003 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 002 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 001 Device 004: ID 0bda:0158 Realtek Semiconductor Corp. USB 2.0 multicard reader Bus 001 Device 002: ID 04f2:b071 Chicony Electronics Co., Ltd 2.0M UVC Webcam / CNF7129 Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub dmesg trying to post dmesg exceeded the stackexchange posting limit of 30K... but nothing there is usb 3.0

    Read the article

  • What options exist when the vendor does not supply an ADB driver for an Android device?

    - by STATUS_ACCESS_DENIED
    So I bought an Android phone and the vendor does not offer any drivers whatsoever. The Android SDK and the drivers that come with it don't seem to work with the device, but the device itself reports as Android 2.2.1. Other users have reported that the drivers of the Nook Color worked for them, but I cannot confirm this, after trying. What options do I have to connect to the device (and ultimately to root it)? Is it truly just the .inf file that I need to manipulate in order to make the device ID known to Windows? After all there are tools to figure out those strings while the device is connected (although "unknown") ...

    Read the article

  • A Question About the Expressive Power of Higher-Order Logical Reasoning Formalisms.

    - by Bubba88
    Hi! I do not really know if this is scientifically proven, but I've read in a book (It was a relatively modern AI book by Peter Norvig) that secon-order logical programming could be more expressive than existing first-order languages. The question is: Is it statistically/symbolically proven that higher-order predicate logics exceed first-order predicates in their expressive power? Or they just bring the modularity/convenience/maintainability to your knowledge bases? Additionally: If there is some kind of firm direction in which I could go seeking more expressive power than I have (I mean exactly the descriptive potential of the symbols I write in given semantics/syntax) - then I would be glad to hear just almost everything :) Thank you.

    Read the article

  • How to restore data on Power Failure using C++ programming on windows.

    - by Tarun
    Hi, In my program I am writing a file of my programs states. I am writing the file many times to the file during the program run, because the program changes some variables that that i need to store very frequently. Now, if , for some reasons my power fails. Then most of the time I loose data in that file. Please, tell me any mechanism which can protect data even if the power fails. (I have written C++ program on windows). Thank you

    Read the article

  • Why does Process Explorer cause highly targeted failure of some applications / basic UI functions in a high-power EC2 Windows instance?

    - by Dan Nissenbaum
    Update: I have determined that Process Explorer itself - the program I am using to debug a performance issue - seems to be the cause of the issue. See note, with updated question, at end. I am running a high-power (cc2.8xlarge) Amazon AWS EC2 Windows instance off of a boot EBS volume, provisioned at 2500 PIOPS, which was created from a snapshot of a previous boot volume. My purpose with the instance is to use it as a development workstation with many developer tools installed, such as Visual Studio, a local XAMPP stack, etc. I have upwards of 40 programs installed on the machine. The usability of the instance as a development machine often works quite well. The RDP lag is adequately small. I have used it for hours on end without problems for some of my most intense development tasks. As a result, I have just purchased a reserved instance, and I opted to rebuild my development machine starting from scratch with a Windows Server 2012 AMI. After having installed all of my desired/required applications for development over this past week, again the machine seems to often work well and I have worked for up to an hour at a time without problems doing heavy development work. However, I continue to run into catastrophic OS usability issues that may prevent me from being able to rely on this machine as a development machine. I would like to track down the source of the problem, if there is an easily identifiable source. (Update: I have tracked down the source to be Process Explorer, the very program I was using to debug the problem. See update at end.) The issues are as follows. (These are some primary examples) Some applications, after a period of adequate responsiveness, suddenly begin to respond very, very slowly to basic user interface actions such as clicking on menus and pressing Ctrl-Tab to switch between open documents. Two examples are UltraEdit and PhpEd. It typically takes ~2 seconds for a menu to appear, and ~4 seconds to switch between open documents. Additionally, insertion point motion in the editor is lagged by upwards of ~2 seconds. Process Explorer, which I am using to help debug the problem, seems to run acceptably for a couple of minutes, but on multiple occasions Process Explorer itself hangs completely. It hangs at the same time as the problems noted above. When it hangs, it is 100% unresponsive. Clicking on its taskbar icon neither causes it to come to the top or go behind, and its viewable area is filled with nothing but a region partially containing pure white and partially containing incomplete windows widgets that are unreadable, and that never change. Waiting 10 minutes does not clear the problem. Attempting to force-quit Process Explorer by right-clicking on its taskbar icon and choosing "Close Window" takes about 5 full minutes to exit (Process Explorer itself can't be used to exit Process Explorer, and it is registered as a Task Manager substitute). Other programs work just fine during this time. For example, Chrome tabs flip very quickly back and forth, menus pop open instantly, web pages load quickly, and typing in forms/web applications inside the browser works promptly. Another example of an application that works crisply is Filemaker - its menus open instantly, and switching views in this application occurs promptly. Other applications also work without issue. Also, switching between applications occurs promptly as well. It is only a handful of applications that exhibit the problem, with some primary examples given above. At first I thought that EBS IOPS might be a problem. Therefore, I ran Performance Monitor, and watched the "Disk Transfers/sec" monitor in real time. At no point did this measure come anywhere close to hitting the 2500 PIOPS provisioned for the EBS volume. The RAM was also well under the limit (~10 GB used out of 60 GB). I did notice that one CPU core (out of 32 logical cores) was fully thrashing at 100% (i.e., ~3.1%) during the problematic periods. This seems to indicate that a single CPU core is handling the menus / flipping between open documents (for some applications only) / managing the Process Explorer user interface, and that this single core was hosed for some reason during the problematic periods. Also note that I have a desktop workstation (Windows 7) that I also use as a development machine, via a remote connection, with a nearly identical set of programs installed, and this desktop workstation does not exhibit any of the problems I've discussed above. I have been using it heavily for well over a year now. Any suggestions regarding either the source of the problem, or steps I might take to investigate the source of the problem, would be appreciated. Thanks. Note: After extensive testing & investigation, I have noticed that when I quit Process Explorer, the problem vanishes and the system performance returns to normal, and then reappears quickly when I run Process Explorer again (note: again, the performance problems only appear for a subset of applications - other applications work perfectly fine during the same period). My question is therefore (thankfully) more specific: Why does Process Explorer cause highly targeted failure of some applications (including itself) and basic UI functions, in a high-power EC2 Windows instance?

    Read the article

  • Why does this monitor go to sleep but won't wake up, event though all related power options are turned off?

    - by VoidKing
    We have a machine, Windows 7 (64-bit) with ASUS motherboard, in our building that only sometimes seems to go to sleep, but won't wake up. The machine is still running but shaking the mouse or hitting keys on the keyboard won't wake it up. I have tried for days to isolate the problem, but every time we get to a "let's try this" scenario, it happens again, later. All power options related to display being off are set to never, except the simple, "turn display off after..." setting. That is, the hard drive is set to never turn off, and the computer is set to never sleep nor hibernate. All drivers seem to be up to date, but I am afraid I will hose the machine if I do a BIOS update (plus I figured that will probably have nothing to do with the issue and only make something else break). Wasn't sure if there was something obvious I was missing?

    Read the article

  • Power cut during Ubuntu upgrade to 10.04 - boots to command line, apt-get and dpkg do not work.

    - by Macha
    I was upgrading Ubuntu to 10.04, when a tripswitch tripped, cutting power to the computer. When it was restarted, it booted into a command line prompt. Google tells me to try: sudo dpkg --configure -a This gets me a lot of output that ends with a list of packages. I can't tell you what the output is, as piping the output to more/less does not work (still just all scrolls by and moves to next prompt), and redirecting it to a file just results in an empty file. Google also suggested: sudo apt-get install -f This also didn't work. Is a fresh install the only solution at this point?

    Read the article

  • Windows 7 on 1st Gen Macbook Pro (Q4-2008), power management problems.

    - by typemismatch
    I have the first generation macbook pro, purchased Q4 2008. I've been trying to run Windows 7 and can get it all installed great with the BootCamp 3.1 64 bit drivers however ... power management isn't great. The screen and keyboard don't automatically dim - the laptop gets too hot. I noticed on some newer macbook pros that windows 7 works perfectly and the above doesn't happen. Does anyone know if there really is a hardware issue with this 1st gen or is there some firmware update I can use to fix this? Thanks!

    Read the article

  • How do I leverage the power of my desktop from my laptop?

    - by TheDeeno
    I have a powerful desktop, and a decent laptop. My laptop is my primary machine. When I'm home, I'd like to "tap into" the power of my desktop while using my laptop. I'm not thinking a solution like "remoting in" and actually using my desktop from my laptop. I mean sending work to the desktop when my laptop is taxed in a seamless way. Is this possible at all? How would I do it? I'll do whatever is necessary to my desktop to enable this if it's feasible. My laptop has Vista installed.

    Read the article

  • Windows 7 on 1st Gen MacbookPro Unibody (Q4-2008) - power problems.

    - by typemismatch
    I have the first generation macbook pro, purchased Q4 2008. I've been trying to run Windows 7 and can get it all installed great with the BootCamp 3.1 64 bit drivers however ... power management isn't great. The screen and keyboard don't automatically dim - the laptop gets too hot. I noticed on some newer macbook pros that windows 7 works perfectly and the above doesn't happen. Does anyone know if there really is a hardware issue with this 1st gen or is there some firmware update I can use to fix this? Thanks!

    Read the article

  • Laptop GPU apparently blew up, motherboard doesn't even turn on its power LED. [But..]

    - by leladax
    If I take out the GPU, the motherboard LED turns on but then [if it attempts to power up and boot] it turns off after 2 seconds [fans turn on normally in that short period]. [Without the GPUs out there's not even an attempt to boot.] It's an SLI motherboard for a toshiba (model X200-219). If I take out one of the GPUs (they are on top of each other) it surprisingly lets the motherboard turn on too (as it is if both are out) but it still turns off after 2-3 seconds, same behavior. I wonder if it's the GPU that produces the 'turn off after being on' behavior and not something else. [Has anyone seen this behavior with blown up GPUs or could it be something else?]

    Read the article

  • How to convert a power point pdf to a pdf that is easy to read on kindle?

    - by SpaceTrucker
    I have several power point presentations as pdfs. I would like to read them on the original kindle in landscape format. When I read the original on the kindle then a single slide won't fit on the kindles display. I thought the easiest way to convert the pdf was to repring it with a pdf printer. However I don't know the paper size to use. I already tried using Calibre as suggested by this question. However the output is not usable because of formatting issues. So what paper size should I use for the pdf printer to reprint them in landscape format or are there any other tools I could use for that task?

    Read the article

  • Configure Linux server hardware buttons for soft reset or power cycle?

    - by Jakobud
    I have a small modest CentOS server at home. I run it headless because anytime I access it, it's always via SSH. Anyways, tonight it became unresponsive to the network. I could not connect to it to investigate. In this case, I have to hook up a keyboard and monitor to see the problem. I ended up just rebooting it. But after this experience, I was wondering if it's possible to configure the hardware buttons on the CPU case to perform a graceful reboot or graceful power cycle in Linux. Even though the server becomes unresponsive once in a blue moon, it would be nice to simply press a button and have it shutdown all services and gracefully reboot. Anyone know how this could be accomplished?

    Read the article

  • Is it possible to power off a PCIe video card/slot? (eg. hot-plug)

    - by CR.
    I'm looking at building a system that supports VT-d so I can pass through a high powered loud video card to a Xen/KVM/whatever VM (host will be Linux based). However, when I'm not using the VM I want to turn the video card off so its fan does not run. The card will not be used when the VM isn't running. Anyone know if this is possible? The PCI-Express hot-plug specification allows cutting power to specific slots but I have never heard of anyone doing it with a video card and my searches for information have turned up nothing.

    Read the article

  • In terms of load handling, which is better: one server or two of equivalent power?

    - by seldary
    My goal is to figure out if i'm better off with one strong server, or multiple weaker servers with a load balancer. Does the fact of splitting the load between servers have an effect on the total load my website could take? It's hard to single that out, because there are of course a lot of parameters that affect the results, so some assumptions: Putting failover considerations aside - I know it matters, but for the sake of the question's simplicity, lets assume nothing fails. The servers in the multiple servers option have an accumulated "power" equivalent to the one server option (about the same amount of cores and RAM space). If that is too theoretical, here is a concrete question that could help: Suppose I have several instances of exactly the same server - lets call it S. Suppose that server S can serve a load of up to X calls per time unit. Will two S servers with a load balancer serve 2X calls per time unit? significantly more? significantly less?

    Read the article

  • Please help me give this principle a name

    - by Brent Arias
    As a designer, I like providing interfaces that cater to a power/simplicity balance. For example, I think the LINQ designers followed that principle because they offered both dot-notation and query-notation. The first is more powerful, but the second is easier to read and follow. If you disagree with my assessment of LINQ, please try to see my point anyway; LINQ was just an example, my post is not about LINQ. I call this principle "dial-able power". But I'd like to know what other people call it. Certainly some will say "KISS" is the common term. But I see KISS as a superset, or a "consumerism" practice. Using LINQ as my example again, in my view, a team of programmers who always try to use query notation over dot-notation are practicing KISS. Thus the LINQ designers practiced "dial-able power", whereas the LINQ consumers practice KISS. The two make beautiful music together. I'll give another example. Imagine a C# logging tool that has two signatures allowing two uses: void Write(string message); void Write(Func<string> messageCallback); The purpose of the two signatures is to fulfill these needs: //Every-day "simple" usage, nothing special. myLogger.Write("Something Happened" + error.ToString() ); //This is performance critical, do not call ToString() if logging is //disabled. myLogger.Write( () => { "Something Happened" + error.ToString() }); Having these overloads represents "dial-able power," because the consumer has the choice of a simple interface or a powerful interface. A KISS-loving consumer will use the simpler signature most of the time, and will allow the "busy" looking signature when the power is needed. This also helps self-documentation, because usage of the powerful signature tells the reader that the code is performance critical. If the logger had only the powerful signature, then there would be no "dial-able power." So this comes full-circle. I'm happy to keep my own "dial-able power" coinage if none yet exists, but I can't help think I'm missing an obvious designation for this practice. p.s. Another example that is related, but is not the same as "dial-able power", is Scott Meyer's principle "make interfaces easy to use correctly, and hard to use incorrectly."

    Read the article

  • Is post-sudden-power-loss filesystem corruption on an SSD drive's ext3 partition "expected behavior"?

    - by Jeremy Friesner
    My company makes an embedded Debian Linux device that boots from an ext3 partition on an internal SSD drive. Because the device is an embedded "black box", it is usually shut down the rude way, by simply cutting power to the device via an external switch. This is normally okay, as ext3's journalling keeps things in order, so other than the occasional loss of part of a log file, things keep chugging along fine. However, we've recently seen a number of units where after a number of hard-power-cycles the ext3 partition starts to develop structural issues -- in particular, we run e2fsck on the ext3 partition and it finds a number of issues like those shown in the output listing at the bottom of this Question. Running e2fsck until it stops reporting errors (or reformatting the partition) clears the issues. My question is... what are the implications of seeing problems like this on an ext3/SSD system that has been subjected to lots of sudden/unexpected shutdowns? My feeling is that this might be a sign of a software or hardware problem in our system, since my understanding is that (barring a bug or hardware problem) ext3's journalling feature is supposed to prevent these sorts of filesystem-integrity errors. (Note: I understand that user-data is not journalled and so munged/missing/truncated user-files can happen; I'm specifically talking here about filesystem-metadata errors like those shown below) My co-worker, on the other hand, says that this is known/expected behavior because SSD controllers sometimes re-order write commands and that can cause the ext3 journal to get confused. In particular, he believes that even given normally functioning hardware and bug-free software, the ext3 journal only makes filesystem corruption less likely, not impossible, so we should not be surprised to see problems like this from time to time. Which of us is right? Embedded-PC-failsafe:~# ls Embedded-PC-failsafe:~# umount /mnt/unionfs Embedded-PC-failsafe:~# e2fsck /dev/sda3 e2fsck 1.41.3 (12-Oct-2008) embeddedrootwrite contains a file system with errors, check forced. Pass 1: Checking inodes, blocks, and sizes Pass 2: Checking directory structure Invalid inode number for '.' in directory inode 46948. Fix<y>? yes Directory inode 46948, block 0, offset 12: directory corrupted Salvage<y>? yes Entry 'status_2012-11-26_14h13m41.csv' in /var/log/status_logs (46956) has deleted/unused inode 47075. Clear<y>? yes Entry 'status_2012-11-26_10h42m58.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47076. Clear<y>? yes Entry 'status_2012-11-26_11h29m41.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47080. Clear<y>? yes Entry 'status_2012-11-26_11h42m13.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47081. Clear<y>? yes Entry 'status_2012-11-26_12h07m17.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47083. Clear<y>? yes Entry 'status_2012-11-26_12h14m53.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47085. Clear<y>? yes Entry 'status_2012-11-26_15h06m49.csv' in /var/log/status_logs (46956) has deleted/unused inode 47088. Clear<y>? yes Entry 'status_2012-11-20_14h50m09.csv' in /var/log/status_logs (46956) has deleted/unused inode 47073. Clear<y>? yes Entry 'status_2012-11-20_14h55m32.csv' in /var/log/status_logs (46956) has deleted/unused inode 47074. Clear<y>? yes Entry 'status_2012-11-26_11h04m36.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47078. Clear<y>? yes Entry 'status_2012-11-26_11h54m45.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47082. Clear<y>? yes Entry 'status_2012-11-26_12h12m20.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47084. Clear<y>? yes Entry 'status_2012-11-26_12h33m52.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47086. Clear<y>? yes Entry 'status_2012-11-26_10h51m59.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47077. Clear<y>? yes Entry 'status_2012-11-26_11h17m09.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47079. Clear<y>? yes Entry 'status_2012-11-26_12h54m11.csv.gz' in /var/log/status_logs (46956) has deleted/unused inode 47087. Clear<y>? yes Pass 3: Checking directory connectivity '..' in /etc/network/run (46948) is <The NULL inode> (0), should be /etc/network (46953). Fix<y>? yes Couldn't fix parent of inode 46948: Couldn't find parent directory entry Pass 4: Checking reference counts Unattached inode 46945 Connect to /lost+found<y>? yes Inode 46945 ref count is 2, should be 1. Fix<y>? yes Inode 46953 ref count is 5, should be 4. Fix<y>? yes Pass 5: Checking group summary information Block bitmap differences: -(208264--208266) -(210062--210068) -(211343--211491) -(213241--213250) -(213344--213393) -213397 -(213457--213463) -(213516--213521) -(213628--213655) -(213683--213688) -(213709--213728) -(215265--215300) -(215346--215365) -(221541--221551) -(221696--221704) -227517 Fix<y>? yes Free blocks count wrong for group #6 (17247, counted=17611). Fix<y>? yes Free blocks count wrong (161691, counted=162055). Fix<y>? yes Inode bitmap differences: +(47089--47090) +47093 +47095 +(47097--47099) +(47101--47104) -(47219--47220) -47222 -47224 -47228 -47231 -(47347--47348) -47350 -47352 -47356 -47359 -(47457--47488) -47985 -47996 -(47999--48000) -48017 -(48027--48028) -(48030--48032) -48049 -(48059--48060) -(48062--48064) -48081 -(48091--48092) -(48094--48096) Fix<y>? yes Free inodes count wrong for group #6 (7608, counted=7624). Fix<y>? yes Free inodes count wrong (61919, counted=61935). Fix<y>? yes embeddedrootwrite: ***** FILE SYSTEM WAS MODIFIED ***** embeddedrootwrite: ********** WARNING: Filesystem still has errors ********** embeddedrootwrite: 657/62592 files (24.4% non-contiguous), 87882/249937 blocks Embedded-PC-failsafe:~# Embedded-PC-failsafe:~# e2fsck /dev/sda3 e2fsck 1.41.3 (12-Oct-2008) embeddedrootwrite contains a file system with errors, check forced. Pass 1: Checking inodes, blocks, and sizes Pass 2: Checking directory structure Directory entry for '.' in ... (46948) is big. Split<y>? yes Missing '..' in directory inode 46948. Fix<y>? yes Setting filetype for entry '..' in ... (46948) to 2. Pass 3: Checking directory connectivity '..' in /etc/network/run (46948) is <The NULL inode> (0), should be /etc/network (46953). Fix<y>? yes Pass 4: Checking reference counts Inode 2 ref count is 12, should be 13. Fix<y>? yes Pass 5: Checking group summary information embeddedrootwrite: ***** FILE SYSTEM WAS MODIFIED ***** embeddedrootwrite: 657/62592 files (24.4% non-contiguous), 87882/249937 blocks Embedded-PC-failsafe:~# Embedded-PC-failsafe:~# e2fsck /dev/sda3 e2fsck 1.41.3 (12-Oct-2008) embeddedrootwrite: clean, 657/62592 files, 87882/249937 blocks

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • Can't Get Mac Mini to turn on - no screen, no beep, only the fan, power light, and optical drive noi

    - by pibyers
    I have an Intel-based Mac mini mid-2007 (Model A1176). This is the computer my kids use so I don't use it regularly. The computer had been working fine until one day my kids told me that it no longer works. The computer will not boot up. When I turn it on the fan turns, the white power light in the front turns on, and there is a sound that appears to be from the optical drive (rather than hard drive). I don't get anything to the monitor, nor do I get any dings or other start up sounds from the computer. Here is what I've tried thus far to no avail: 1) Swapped out the monitors early on since I figured that was my weak link - no change 2) Reset the PMU - no change 3) Tried to boot up from the System Disk - The mini loaded the dvd into the drive, but nothing else (I can't eject the disk so I can put it back) 3) Start up the computer in target mode connected to another mac - I tried this too, but I never received a chime or the disk show up on the other mac. I'm about out of ideas apart from scraping the computer. Does anyone have any ideas that I can try? Again, nothing has been done to the computer in at least 6 months when I upgraded the RAM. I'm also still on Leopard. Thanks.

    Read the article

  • What can I do to prevent system power downs?

    - by Joe King
    Yesterday I was given my brother's old laptop - core i7, 2.67GHz, 8GB RAM, 128GB SSD, Win7 64 bit. It's a Sony Vaio Z11. Approx 18 months old. When running something computationally intensive, the fan starts up and after about 30 secs it just powers itself down with no warning. I guess it is overheating. There is nothing in the event logs to suggest what is causing it - the only thing I see is "the last system shutdown was unexpected" or something similar. This is a problem for me because I use a lot of number crunching apps, which pretty much makes it useless to me. I would like to know if there is anything I can do, other than the obvious things I've done already - open up and clean out dust, re-install the OS. According to my brother, this problem started about 6 months ago when it was already outside warranty. If it's just used for simple things - web browsing, word processing etc, the problem does not occur. Any ideas for what I can do to fix this ? Update: I found that the laptop has 2 hardware settings for graphics: Speed and Stamina - the Speed setting seems to use an nvidia GEforce GT 330M, while the Stamina setting uses an Intel chipset. With the setting on Speed, I can hear the fan the whole time, and the system powers down after a short while (5-10 mins) even just doing basic tasks (browsing this site for example), but doesn't shut down if I just leave it switched on. In this mode it also sometimes just freezes the screen and I have to power off myself. However on Stamina setting it only powers down when doing number crunching and never freezes the screen.

    Read the article

  • Is there a way to force the monitor to power off in Windows 8?

    - by Rune Jacobsen
    I have googled this a bit and looked at powrprof.dll and PsShutdown but I haven't found a way to do exactly what I want to do. You know that power save option that lets Windows turn off your monitor(s) if you haven't touched the system for x amount of time? Well, I have a PC that needs to be on most of the day (and night), and I have to watch it much of the time, so I can't have a short timeout for automatically turning off the monitor. However, once I leave it for a few hours (happens at varying times of the day), I would like to be able to issue a command that puts the computer in this mode. Not sleep mode, not hibernate mode. Monitor off, that is all. I realize of course I could just turn the physical monitor off. That is not what I want. This Dell monitor takes forever to display a picture from a cold state. If it is turned off by the computer not sending a signal - not so bad. Is there any way for me to do this? As mentioned, the OS can do it, so I would find it really useful if I could do it too. :)

    Read the article

  • Pull network or power? (for contianing a rooted server)

    - by Aleksandr Levchuk
    When a server gets rooted (e.g. a situation like this), one of the first things that you may decide to do is containment. Some security specialists advise not to enter remediation immediately and to keep the server online until forensics are completed. Those advises are usually for APT. It's different if you have occasional Script kiddie breaches. However, you may decide to remediate (fix things) early and one of the steps in remediation is containment of the server. Quoting from Robert Moir's Answer - "disconnect the victim from its muggers". A server can be contained by pulling the network cable or the power cable. Which method is better? Taking into consideration the need for: Protecting victims from further damage Executing successful forensics (Possibly) Protecting valuable data on the server Edit: 5 assumptions Assuming: You detected early: 24 hours. You want to recover early: 3 days of 1 systems admin on the job (forensics and recovery). The server is not a Virtual Machine or a Container able to take a snapshot capturing the contents of the servers memory. You decide not to attempt prosecuting. You suspect that the attacker may be using some form of software (possibly sophisticated) and this software is still running on the server.

    Read the article

  • Running two graphics cards (non-SLI) to power 3D on two different monitors?

    - by Delameko
    Hi, I'm a bit clueless about this, so excuse my naivety. I have two video cards, a Nvidia 8800 and a GT120, powering three monitors. I run two 3D game instances (two Everquest 2 clients), one on each of my first two monitors. It's been running fine, although sometimes it sounds like the computer is trying to take off. Today I realised that I was actually playing them on the two monitors that are both powered by the 8800. Thinking that I might as well make use of the power of both cards I tried switching the monitor cables over so that each card would be "powering" one of the clients. (Is it silly to assume this is how it works?) This doesn't seem to have had the desired effect, as the client running on the 8800 screen is running worse than it was before. Is it even possible to run two clients on separate GPUs? Is SLI the only way to utilise 2 GPUs? Is there something special I have to do? Or do I have to set the client to use a particular GPU (an option I can't seem to find in EQ2)? I run the clients in window mode if that makes any difference, and I'm running Win 7. Thanks.

    Read the article

  • Orchestrating the Virtual Enterprise, Part II

    - by Kathryn Perry
    A guest post by Jon Chorley, Oracle's CSO & Vice President, SCM Product Strategy Almost everyone has ordered from Amazon.com at one time or another. Our orders are as likely to be fulfilled by third parties as they are by Amazon itself. To deliver the order promptly and efficiently, Amazon has to send it to the right fulfillment location and know the availability in that location. It needs to be able to track status of the fulfillment and deal with exceptions. As a virtual enterprise, Amazon's operations, using thousands of trading partners, requires a very different approach to fulfillment than the traditional 'take an order and ship it from your own warehouse' model. Amazon had no choice but to develop a complex, expensive and custom solution to tackle this problem as there used to be no product solution available. Now, other companies who want to follow similar models have a better off-the-shelf choice -- Oracle Distributed Order Orchestration (DOO).  Consider how another of our customers is using our distributed orchestration solution. This major airplane manufacturer has a highly complex business and interacts regularly with the U.S. Government and major airlines. It sits in the middle of an intricate supply chain and needed to improve visibility across its many different entities. Oracle Fusion DOO gives the company an orchestration mechanism so it could improve quality, speed, flexibility, and consistency without requiring an organ transplant of these highly complex legacy systems. Many retailers face the challenge of dealing with brick and mortar, Web, and reseller channels. They all need to be knitted together into a virtual enterprise experience that is consistent for their customers. When a large U.K. grocer with a strong brick and mortar retail operation added an online business, they turned to Oracle Fusion DOO to bring these entities together. Disturbing the Peace with Acquisitions Quite often a company's ERP system is disrupted when it acquires a new company. An acquisition can inject a new set of processes and systems -- or even introduce an entirely new business like Sun's hardware did at Oracle. This challenge has been a driver for some of our DOO customers. A large power management company is using Oracle Fusion DOO to provide the flexibility to rapidly integrate additional products and services into its central fulfillment operation. The Flip Side of Fulfillment Meanwhile, we haven't ignored similar challenges on the supply side of the equation. Specifically, how to manage complex supply in a flexible way when there are multiple trading parties involved? How to manage the supply to suppliers? How to manage critical components that need to merge in a tier two or tier three supply chain? By investing in supply orchestration solutions for the virtual enterprise, we plan to give users better visibility into their network of suppliers to help them drive down costs. We also think this technology and full orchestration process can be applied to the financial side of organizations. An example is transactions that flow through complex internal structures to minimize tax exposure. We can help companies manage those transactions effectively by thinking about the internal organization as a virtual enterprise and bringing the same solution set to this internal challenge.  The Clear Front Runner No other company is investing in solving the virtual enterprise supply chain issues like Oracle is. Oracle is in a unique position to become the gold standard in this market space. We have the infrastructure of Oracle technology. We already have an Oracle Fusion DOO application which embraces the best of what's required in this area. And we're absolutely committed to extending our Fusion solution to other use cases and delivering even more business value. Jon ChorleyChief Sustainability Officer & Vice President, SCM Product StrategyOracle Corporation

    Read the article

  • How to generate and encode (for use in GA), random, strict, binary rooted trees with N leaves?

    - by Peter Simon
    First, I am an engineer, not a computer scientist, so I apologize in advance for any misuse of nomenclature and general ignorance of CS background. Here is the motivational background for my question: I am contemplating writing a genetic algorithm optimizer to aid in designing a power divider network (also called a beam forming network, or BFN for short). The BFN is intended to distribute power to each of N radiating elements in an array of antennas. The fraction of the total input power to be delivered to each radiating element has been specified. Topologically speaking, a BFN is a strictly binary, rooted tree. Each of the (N-1) interior nodes of the tree represents the input port of an unequal, binary power splitter. The N leaves of the tree are the power divider outputs. Given a particular power divider topology, one is still free to map the power divider outputs to the array inputs in an arbitrary order. There are N! such permutations of the outputs. There are several considerations in choosing the desired ordering: 1) The power ratio for each binary coupler should be within a specified range of values. 2) The ordering should be chosen to simplify the mechanical routing of the transmission lines connecting the power divider. The number of ouputs N of the BFN may range from, say, 6 to 22. I have already written a genetic algorithm optimizer that, given a particular BFN topology and desired array input power distribution, will search through the N! permutations of the BFN outputs to generate a design with compliant power ratios and good mechanical routing. I would now like to generalize my program to automatically generate and search through the space of possible BFN topologies. As I understand it, for N outputs (leaves of the binary tree), there are $C_{N-1}$ different topologies that can be constructed, where $C_N$ is the Catalan number. I would like to know how to encode an arbitrary tree having N leaves in a way that is consistent with a chromosomal description for use in a genetic algorithm. Also associated with this is the need to generate random instances for filling the initial population, and to implement crossover and mutations operators for this type of chromosome. Any suggestions will be welcome. Please minimize the amount of CS lingo in your reply, since I am not likely to be acquainted with it. Thanks in advance, Peter

    Read the article

< Previous Page | 43 44 45 46 47 48 49 50 51 52 53 54  | Next Page >