Search Results

Search found 1506 results on 61 pages for 'replacement'.

Page 47/61 | < Previous Page | 43 44 45 46 47 48 49 50 51 52 53 54  | Next Page >

  • Computer Won't Boot Properly, unless in safe mode?

    - by Mr_CryptoPrime
    I bought a computer today and booted it up, but when I did I only got a blank screen. I checked to make sure it wasn't the monitor by connecting it to my old computer...it worked. I then tried connecting my monitor to both DVI ports and found that the bottom one did work. However, now it just boots up and says "loading windows" and then when the login screen is suppose to come up the screen just goes blank and monitor says "no input, check cord" (or something like that). I tried reinstalling windows and then I was able to log on normally. I used the CD's and reinstalled all the drivers, then rebooted...now I am stuck right back where I started. I tried taking out the RAM and inserting into different slots, that didn't fix anything. I was able to boot up into windows using safe-mode. I suspected that my ATI Radeon 6950 was the issue and downloaded the drivers, but I can't install them on safe-mode. Someone said to install C++ distr. and I tried doing that to fix driver installation problem of "failed to load detection driver" but it wouldn't let me do that either. Please someone help me, I don't want to have to deal with the evil redtape of sending it back to get a replacement! My computer: -Content--text-_-"http://www.newegg.com/Product/Product.aspx?Item=N82E16883229236&nm_mc=TEMC-RMA-Approvel&cm_mmc=TEMC-RMA-Approvel--Content--text-_- Driver detection problem: http://www.hardwareheaven.com/hardwareheaven-tools-discussion/174912-failed-load-detection-driver-installation-error.html Driver download page: http://sites.amd.com/us/game/downloads/Pages/radeon_win7-64.aspx#1 I am using windows 7. Thanks again.

    Read the article

  • PC -> TV HDMI suddenly doesn't work, any other option does

    - by XSlicer
    So my parents wanted to connect their PC to their TV, so they bought a 10m (35 ft) cable. It all worked perfectly. Then my mom tripped over the cable, breaking it. She somehow got a free replacement, but at the same time some more expensive one from an uncle. Now the problem is that this suddenly doesn't work anymore (TV saying "Format not supported"). I've tried several other things to pinpoint the actual problem, but none brought me something conslusive: PC (hdmi) to TV doesn't work (both cables) PC (hdmi) to TV doesn't work (short cable) Laptop (hdmi) to TV work (same cables) BluRay (hdmi) to TV works (same cables) PC (hdmi) to monitor works (same cables) PC (DVI w/ adapter HDMI) to TV works (same cables) I've tried different ports, tried Linux, reinstalling drivers (the graphics card is internal using an i5 sandy bridge. Normally it's running Windows 7 Home Prem, the TV being a Philips 37PFL7605H). So basically, everything works, except that thing what we want. The only things I am thinking of is that the sound is interfering or that the HDMI-output is somehow broken. Or is it anything else? I'm kind of lost.

    Read the article

  • How to migrate WinXP from failing old HD to new one

    - by Péter Török
    Following this issue, we have all our important data backed up now. I also bought and installed a new replacement hard disk (WD 160GB PATA) as secondary (slave) drive. I created two primary NTFS partitions on it: a 40 GB system partition, and a 110GB data partition. In theory I could start reinstalling WinXP from scratch on the new system partition, then copying over all user data from the old drive to the new data partition. Once this is done, I could even throw away the old drive, or keep it just to see what happens. (Note: I don't want to clone the whole drive as it contains a dual boot setup with an old Linux installation which I don't need anymore, and anyway, a fresh reinstall would do WinXP good to get rid of many years' clutter.) However, I am lazy :-) The old HD is still functioning, the problem has not manifested again since. So I feel there is no need to hurry with a complete OS reinstall. What I don't know though is whether I will be able to install WinXP on the new system partition at a later stage without affecting the contents of the data partition on the same drive. If this is possible, I can just move over all our data to the new data partition to have it safe, then continue running WinXP from the old drive as long as it works. Does anyone see any problems/risks with this plan?

    Read the article

  • Are these three brand new sticks of RAM really dead?

    - by David Brown
    I'm working on a Dell Dimension 4700 desktop for a friend. It came with 512MB of DDR2 RAM (two sticks of 256MB). One morning, it started blue screening on startup with no helpful error messages. It refused to boot into any form of Windows installation, including Safe Mode, original recovery disk, and my custom Windows PE disk. It did boot into the Ultimate Boot CD, so I ran memtest86, which reported errors everywhere. I removed one stick of RAM and the system booted up just fine. I moved the remaining stick into each slot and the system continued to operate normally, so I came to the conclusion that the stick that I removed was dead. I ordered an exact replacement, along with 2 more sticks of 256MB DDR2 (again, exactly the same as the original), bringing the total system memory to 1GB. Upon installing the three brand new sticks, the system blue screened again, this time stating that win32k.sys attempted to write to read-only memory. I inserted my custom Windows PE disk in order to get a better look at the memory dump with BlueScreenView, but it refused to boot and produced another blue screen, but without an error message. I removed each new stick one-by-one, restarting each time. It continued to blue screen until I was left with only the original stick. I then tried inserting the new sticks in various different orders, but this only produced more blue screens. I reinserted all three sticks (along with the original) and ran memtest86 again, which reported errors all over the place. So, now I'm right back where I started. I don't think it could be the slots themselves, because I can plug the original stick into any slot and it works just fine. System setup reports each stick correctly and shows the total as 1GB, however. It just seems strange to me that all three brand new sticks of RAM could be dead on arrival. Is there something I missed? Or should I just go ahead and RMA them?

    Read the article

  • Unusable network, packet losses between router and NIC

    - by KáGé
    I have this setup: Gigabyte P35-DS3P motherboard Asus NX1101 PCI network card (the one on the motherboard got fried a few years ago by a power surge) Asus RT-N16 router Windows 7 x64 I think the other specs are irrelevant here, but I'll post them if you say so. Until a week ago everything was fine, but then my network became unusable: websites start loading but timeout before anything would come through (true for the web interface of the router as well), I can't reach the computer from my notebook and Windows' ping utility measures a ~50% packet loss between the computer and the router. Pinging localhost is good. The router works completely fine when wired to my notebook. I also tested different ports on the router, different cables, different router and connecting directly to the modem, but it's still the same. Sometimes it works for a few minutes right after turning on the machine, but then it becomes crap again, but mostly it's useless from the start. I've tried updating the firmware on the router, updating the driver for the network card (after which I started getting BSoDs in every 15 minutes), reinstalling Windows, swapping to Fedora 15 but none of them changed anything. Does this mean that the network card is dying, or could it be something else? If it's the card, what model do you recommend as a replacement? (Could be PCI or PCI-Ex x1) Thanks for your help.

    Read the article

  • Flash Backed Write Cache (FBWC) without capacitor pack

    - by Martyn
    I brought a HP Smart Array P410 controller and it is installed and working fine in a HP Prolient Microserver with 4 drives in two RAID 1 arrays. I didn’t realise however that it came without any cache so would only work by directly writing straight to the disk, and the performance was horrible. So I then brought the 512MB Flash Backed Write Cache (FBWC) memory module as I was under the impression that with FBWC I would not need a battery. I got this idea from a forum post. "What do you guys think of the choice between 'BBWC' (battery backed write cache) and 'FBWC' (flash backed write cache)? The flashed based ones use non-volitile memory so need no battery." After installing the cache module however the server pretty much won’t boot. The P410 has a flashing amber light on it, and from the manual that doesn’t sound good. I’ve managed to get to the on board BIOS once and even managed to get to boot to the HP Array Configuration Utility (ACU) CD once, but every other time the Server continuingly reboots once it get to the POST screen and reads ARRAY INITILIZING %%%. The one time I reached the ACU, it reported a problem with the Cache Module. To me, it seems like the cache module is faulty, however the supplier tells me “Do you have an FBWC battery pack, p/n 587324-001, because that is required for the cache to work. If you have it, please complete an RMA form and we'll send a replacement / credit.” Does this sound right to you? I’ve been ordering the parts from the US and I don’t want to spend $77 + $40 p&p on a battery, wait a week for the shipping to find the card is faulty, and I don’t want to send back a working card?

    Read the article

  • program to track recent saved files or downloads?

    - by DiegoDD
    Back to windows XP times, i used a program named Ava Find that can find any file in the system, but a really nice feature it had, called "scout bot" that automatically finds new files, that is, recently created. More info here: AvaFind For example, if i saved or downloaded a file (in any program), but i cant remember its name or where i put it, i just simply looked at the scoutbot list, and it showed me the most recent files, and then i could just open them from there, or jump to their path. Since i changed to windows 7 (passing through vista), the program no longer works. It simply keeps indexing forever and never finds anything. I don't know if it is not compatible with win 7 itself, or because the fact that my windows 7 is 64 bit. I already tried to contact the Avafind creators, but they never answered, and the program seems to be no longer supported (although the site still works). Now, is there a similar program that finds RECENT files? e.g. listing the most recently saved files, system-wide (or even limiting it to some folders, discs)? And that of course, that is confirmed to work with win 7 64 bit. I know that there are many programs that can find any file, like everything, but what i want is to find recent files and their paths, without knowing their name or e. "everything" also can sort results by date, which is almost what i need, simply to look for part of the file name or extension, and get the most recent one. but if i get to many results, it takes a while, plus, i STILL need to know the name or at least extension of the file. What i want is simply a "Most recently Saved files" tool. i.e., a replacement for Scout Bot in Ava Find. Do you know any alternative?

    Read the article

  • Seperate external and intranet portals using the same functions .htaccess

    - by jezzipin
    We are currently struggling with setting up rules for a .htaccess file for a website built upon our company product. The product is built using PLSQL and procedures can be accessed using URLs. We use this functionality to present different options to our users. These options can be injected into HTML pages using replacement tags. So, the tag [user_menu] is always replaced with: /wd_portal_cand.menu?p_web_site_id={variable1}&p_candidate_id={variable2} for external sites and /intranet/wd_portal_cand.menu?p_web_site_id={variable1}&p_candidate_id={variable2} for internal sites. The issue we are having is twofold. We need to write our .htaccess rules so that the user can access the functionality whether they are internal or external. So, the links should work as follows: http://www.example.com/wd_portal_cand.menu?p_web_site_id={variable1}&p_candidate_id={variable2} or http://www.example.com/internal/wd_portal_cand.menu?p_web_site_id={variable1}&p_candidate_id={variable2} This is the other problem. As you can see for the internal link above, the procedure needs to be prefixed with internal instead or intranet. We cannot change this in our standard tags as this will affect other sites so we need to achieve this also using htaccess. Could anyone assist with this issue? I apologise if this is brief or confusing but it's something i've never done before and have been given the task of doing. I apologise for the lack of code that will be posted above however I am a front end developer and have been left to make these changes having no prior experience of .htaccess to please bare with me.

    Read the article

  • saving data from a failing drive

    - by intuited
    An external 3½" HDD seems to be in danger of failing — it's making ticking sounds when idle. I've acquired a replacement drive, and want to know the best strategy to get the data off of the dubious drive with the best chance of saving as much as possible. There are some directories that are more important than others. However, I'm guessing that picking and choosing directories is going to reduce my chances of saving the whole thing. I would also have to mount it, dump a file listing, and then unmount it in order to be able to effectively prioritize directories. Adding in the fact that it's time-consuming to do this, I'm leaning away from this approach. I've considered just using dd, but I'm not sure how it would handle read errors or other problems that might prevent only certain parts of the data from being rescued, or which could be overcome with some retries, but not so many that they endanger other parts of the drive from being saved. I guess ideally it would do a single pass to get as much as possible and then go back to retry anything that was missed due to errors. Is it possible that copying more slowly — e.g. pausing every x MB/GB — would be better than just running the operation full tilt, for example to avoid any overheating issues? For the "where is your backup" crowd: this actually is my backup drive, but it also contains some non-critical and bulky stuff, like music, that aren't backups, i.e. aren't backed up. The drive has not exhibited any clear signs of failure other than this somewhat ominous sound. I did have to fsck a few errors recently — orphaned inodes, incorrect free blocks/inodes counts, inode bitmap differences, zero dtime on deleted inodes; about 20 errors in all. The filesystem of the partition is ext3.

    Read the article

  • Network Sniffing and Hubs

    - by Chris_K
    This will likely seem naive to the experts... but it has been on my mind lately. For years I've been using ntop and a cheap 4 port hub to sniff client networks to determine who's doing what -- and how much. Great way to see what's going on when they call and say "Geeze, the network seems really slow today." No need to bring in a managed switch (or access the existing one) and no need to configure spanning or mirroring. I just drop in the hub inline where I want to measure. Lately I noticed it is just about impossible to buy a real honest-to-goodness hub anymore. While looking for a new one, I had someone tell me that I should be sure to get a full-duplex hub or I'd only be seeing half the traffic when I monitor. Really? I've been using a crusty old Netgear DS104 all this time. No clue if it is half or FD. Have I really been understating my measurements? I'm just not bright enough about the physical layer to really know... Side note: Just ordered a Dualcomm Ethernet Switch TAP as a hub replacement. Seems like a nifty gadget. Any notes or tips about it would be welcome in the comments :-)

    Read the article

  • VM load and ping problems after replacing server motherboard

    - by Andre
    Recently, we had to replace the motherboard of one of our servers. The procedure was done by IBM as it had guarantee. The server runs ESXi 5.1, with several virtual machines, including our main mail server (Domino) and a file server. After the replacing the motherboard and staring the VMs, ESXi asked us if we had moved it or copied (different motherboard is like a different computer). We clicked the latter. We started each machine and after some basic reconfiguration, all of them were up. However, we have been having problems with the mail server, it has been acting really slow at times (this could be when it syncs with the secondary mail server) and we have been checking with Centreon (a Nagios frontend) that its CPU load has been a bit high at times and ping response too. There was a moment this morning in which I tried connecting via SSH console and it was really slow to show login and basic commands like ifconfig and top. This particular mail server is a CentOS 4.4.7 64-bit. The little configuring we had to do after restarting it was to configure the network connection as it was resolving through DHCP. Our mail software is Lotus Notes server 9. Do you know of any way in which this replacement may be causing these difficulties, and how to fix it? Thanks.

    Read the article

  • VNC Server that can be used from command line?

    - by jesusiniesta
    I'm looking for a replacement for a custom vnc server that we have been using in my company for a long time. I need a simple executable that can be run from command line by an IT Support software without the user noticing it (our application will warn the user, we don't want him to see we are using that VNC sever). I need it to support Windows and preferably also OSX. The only option I've found is UltraVNC, but I can't configure it from command line to accept loopback connections without authentication. We have already a whole VNC Viewer + VNC Repeater + Bouncers architecture, and the only missing piece is the VNC Server. Do you know any solution you could suggest me? I'm afraid I'll end up developing a new VNC server myself, may be based on an open source one. EDIT: When I said I don't want the user to notice this VNC server, I should have added that I don't want him even noticing the installation. So better if it can be installed silently or can be executed as a portable executalbe (for instance, ultravnc can be installed and ran as a service from command line, or simply executed quietly, with only a notification icon; its problem is that I can't run it without authentication).

    Read the article

  • What are my options in replacing the noisy fan in my Linksys Cisco SRW2008P managed GigE switch?

    - by Fred Sobotka
    My first managed GigE switch, the Linksys SRW2008, was a dream, until it started randomly chattering on various ports. That started while I was on the road all the time, which made it take forever to diagnose, but that's a different problem. When I finally determined that the switch was bad, it was still covered by warranty by Linksys/Cisco, so I opened an RMA ticket and returned it. Unfortunately, Linksys/Cisco "upgraded" my replacement switch to a SRW2008P, which has Power over Ethernet features I never planned on using. That by itself wasn't so bad, but it's my guess that the inclusion of PoE functions in this model required a tiny, super-loud internal fan to keep everything cool. This wasn't something I wanted or asked for, but, now that I am stuck with it, I am investigating options for replacing that little internal fan with something far quieter. For example, if I attach a larger fan to the outsite of the chassis, I think it could push enough air to replace the stock fan that is currently there. Any advice on carrying this out? I have no interest in melting my switch due to insufficient ventilation.

    Read the article

  • Hardware testing tool/suite

    - by Aviator
    Hi All, I just bought a new core i5 system (assembled) and started installing Windows 7. It was failing for many times and at some point got installed. After that, frequent crashes related to MEMORY. So checked the RAM using memtest86+ and found many errors.I got it replaced with the vendor and now if i install ANY OS, at some point in installation it either freezes completely with no response for hours, or restarts automatically. I tried installing Windows 7, Windows Vista and Ubuntu 9.10. I tested the new RAM again and found no problems in about 2 passes using memtest86+. I even updated the BIOS using bootable USB and even the problem persists. I am really not sure which hardware is causing trouble. I dont have any OS inside it, so i have to check using bootable CDs DVDs and USB only. Please advice on how to proceed. Are there any suites/ separate tools for checking integrity of each hardware parts and troubleshoot it? I wanted to confirm which part is problematic before going for replacement. Thanks a lot! This is the config: Core i5, MSI P55-GD65, GSKill 2x2GB, Seagate 500GB 7200rpm, CM Extreme 600W PSU, Saphhire Radeon 5770 1GB, LG DVD Writer

    Read the article

  • Disaster Recovery Standby Server

    - by user64300
    Hi, I work for a small business with 25 users and 2 servers. 1 server is the DC running Windows Server 2003/Exchange 2003. We want a reliable disaster recovery strategy for this server without having to spend a lot of money. We take regular backups but I have been advised that only an identical server will allow them to be restored easily. I'm trying to come up with a solution that means we don't have to buy two servers at twice the cost everytime we upgrade. I'm toying with the idea of upgrading our DC more frequently (say every 3 years) and then using the old server as the recovery server (temporarily - until we can source a replacement server). However, I won't know whether the backups will restore on the old server until I try it! We're planning to upgrade to Server 2008R2 in the near future so I'm hoping the backup tools will give me some success in restoring to different hardware (or perhaps I can use hyper-v if not). So what I am wondering is whether it is a idea to use old hardware as a disaster recovery strategy (providing we regular test it obviously!).

    Read the article

  • mod_rewrite changes case even if not matching RewriteCond?

    - by kirdie
    I have a really strange problem with my MediaWiki which I want to have articles of the form mywiki.org/MyArticle. Now I got most of it to work using the following code but it mysteriously cannot display the logo anymore. RewriteEngine On # don't rewrite valid requests to files and directories RewriteCond %{DOCUMENT_ROOT}%{REQUEST_URI} !-f RewriteCond %{DOCUMENT_ROOT}%{REQUEST_URI} !-d # mywiki.org/MyArticle gets rewritten to mywiki.org/index.php/MyArticle RewriteRule ^/(.*)$ /index.php/$1 [L,QSA] Now when I type in mywiki.org/img/logo.jpg in my browser the adress changes to http://wiki.geoknow.eu/Img/logo.jpg (capital I) and I get to the empty article page but the image is definitely there (in my document root under the img folder): /var/www/mywiki.org$ ls img logo.jpg So far so bad. But now it gets really crazy: When I add RewriteCond %{REQUEST_URI} !^/.*\.jpg my adress still gets rewritten and my access log says - - [05/Dec/2012:16:30:21 +0100] "GET /Img/geoknow_logo.jpg HTTP/1.1" 404 509 "-" "Mozilla/5.0 (X11; Linux x86_64; rv:17.0) Gecko/17.0 Firefox/17.0" Where does that capital I in Img come from? The rule is not even executed because at least one condition is definitely not met now and I also don't have any to lowercase-transformation defined anywhere. What is happening there and how can I repair this? P.S.: Now all of the sudden the problem went away (the image is displayed as it should and there is no capital replacement anymore. What can cause this and why does it spontanously appear and disappear?

    Read the article

  • Clone a Windows Installation to a 3TB Hard Drive; MBR to GPT

    - by DanBlakemore
    I have Windows 7 Professional 64-bit installed on my desktop. Unfortunately for me and my wallet my hard drive is failing. I have purchased a 3TB hard drive as a replacement for my current 2TB drive. I would like to avoid as much hassle as possible in moving to this new drive so I would like to copy my current partition to the new drive using Gparted. The problem is that I suspect that my current partition is MBR, and I need GPT on my new drive since it is 3TB. Can I simply copy the MBR partition onto the new disk and then convert it to GPT after the fact (can you even convert the type of a partition)? Or would I need to somehow copy the contents of the partition into a GPT partition on the new drive? How do I go about making this transistion? Also, are there any issues I should be wary of booting to a GPT partition? If it matters, my motherboard is 1 year old as of May, 2012. Edit: My motherboard is 1 day old. My old one does not have UEFI compatibility, so I decided to make an upgrade to Intel today given that I would need a UEFI motherboard to use my new HDD. How much can I use a dying hard drive (bad sectors according to Hitachi Drive Fitness Test)? I have assumed not at all, to be safe.

    Read the article

  • Computer Won't Boot Properly, unless in safe mode?

    - by Mr_CryptoPrime
    I bought a computer today and booted it up, but when I did I only got a blank screen. I checked to make sure it wasn't the monitor by connecting it to my old computer...it worked. I then tried connecting my monitor to both DVI ports and found that the bottom one did work. However, now it just boots up and says "loading windows" and then when the login screen is suppose to come up the screen just goes blank and monitor says "no input, check cord" (or something like that). I tried reinstalling windows and then I was able to log on normally. I used the CD's and reinstalled all the drivers, then rebooted...now I am stuck right back where I started. I tried taking out the RAM and inserting into different slots, that didn't fix anything. I was able to boot up into windows using safe-mode. I suspected that my ATI Radeon 6950 was the issue and downloaded the drivers, but I can't install them on safe-mode. Someone said to install C++ distr. and I tried doing that to fix driver installation problem of "failed to load detection driver" but it wouldn't let me do that either. Please someone help me, I don't want to have to deal with the evil redtape of sending it back to get a replacement! My computer: -Content--text-_-"http://www.newegg.com/Product/Product.aspx?Item=N82E16883229236&nm_mc=TEMC-RMA-Approvel&cm_mmc=TEMC-RMA-Approvel--Content--text-_- Driver detection problem: http://www.hardwareheaven.com/hardwareheaven-tools-discussion/174912-failed-load-detection-driver-installation-error.html Driver download page: http://sites.amd.com/us/game/downloads/Pages/radeon_win7-64.aspx#1 I am using windows 7. Thanks again.

    Read the article

  • PC doesn't POST with a certain model of PSU

    - by Core Xii
    I have this PC with an Asus P5N32-E SLI motherboard and an Intel Q6600 CPU. I got a new RX-5300 PSU, but it didn't work. The motherboard power LED is on fine When I switch power on, the PC powers up briefly (0.5-1 sec) then shuts down From there on out when I switch power on, it stays on, all fans and components seem to be receiving power, but the motherboard won't POST. No video output, no PC speaker beeps, nothing If I turn the hard switch on the PSU off and then back on again, go to step 2; The PC turns on and then off immediately again, and on subsequent power-ups it stays on but won't POST I disconnected every component but the motherboard, CPU and PSU. Still nothing. I tried three other models of PSU on this PC, both of higher (600) and lower (<300) wattage than the 530 on the RX-5300 and they all work fine. At this point I was convinced the PSU was faulty so I returned it. When the replacement arrived, it behaved exactly the same. So two different units of RX-5300 both with the same symptoms, neither working with this motherboard + CPU. Yet, three other models of PSU work perfectly fine. The PC store couldn't reproduce my problem with the returned PSU. I tried resetting the CMOS with the jumper. I tried with both the 4 and 4+4 (with and without the extra +4 connected) CPU connectors (curiously the RX-5300 comes equipped with both). Could it be a statistical probability that I get two units of the same model of PSU that are faulty in the exact same manner? Could the RX-5300 model itself be somehow incompatible with this motherboard? I was under the impression that PSUs were pretty much universal so long as you have the wattage. Could the motherboard be broken in some such a way as to work with certain PSUs but not others? What's going on here?

    Read the article

  • Is there any functional-like unix shell?

    - by Caruccio
    I'm (really) newbie to functional programming (in fact only had contact with it using python) but seems to be a good approach for some list-intensive tasks in a shell environment. I'd love to do something like this: $ [ git clone $host/$repo for repo in repo1 repo2 repo3 ] Is there any Unix shell with these kind of feature? Or maybe some feature to allow easy shell access (commands, env/vars, readline, etc...) from within python (the idea is to use python's interactive interpreter as a replacement to bash). EDIT: Maybe a comparative example would clarify. Let's say I have a list composed of dir/file: $ FILES=( build/project.rpm build/project.src.rpm ) And I want to do a really simple task: copy all files to dist/ AND install it in the system (it's part of a build process): Using bash: $ cp ${files[*]} dist/ $ cd dist && rpm -Uvh $(for f in ${files[*]}; do basename $f; done)) Using a "pythonic shell" approach (caution: this is imaginary code): $ cp [ os.path.join('dist', os.path.basename(file)) for file in FILES ] 'dist' Can you see the difference ? THAT is what i'm talking about. How can not exits a shell with these kind of stuff build-in yet? It's a real pain to handle lists in shell, even its being a so common task: list of files, list of PIDs, list of everything. And a really, really, important point: using syntax/tools/features everybody already knows: sh and python. IPython seams to be on a good direction, but it's bloated: if var name starts with '$', it does this, if '$$' it does that. It's syntax is not "natural", so many rules and "workarounds" ([ ln.upper() for ln in !ls ] -- syntax error)

    Read the article

  • cheap gigabit switch for small business

    - by neoice
    my friend's business is currently borrowing my Adtran 1224R and is very happy with it. it's configured with a few VLANs to segment customers, internal traffic and public wifi. port 1 is a "trunk" port to the router, a chunky Linux box with iptables+NAT. they push a lot of traffic over the LAN (data backups) and really need gigabit. besides, I'd like my Adtran back :P my goal is to find a cheap(ish) switch that can function as a drop-in replacement. it looks like VLAN trunking is actually part of the 802.1q spec, so anything with VLAN support should cover the current trunk-to-router setup. it's nice to have both a web interface and SSH, but I can configure it either way if needed. things like the Netgear GS724T have caught my eye, but it seems like none of the hardware in the $300-500 range have really solid reviews. I'm concerned that "cheaper" hardware might not work for a network full of power users. does anyone have a recommendation for the Netgear GS724T or a switch that will meet my needs?

    Read the article

  • install Oracle’s VirtualBox

    - by Shamith c
    I am trying to install Oracle’s VirtualBox. I used sudo dpkg -i virtualbox-4.2_4.2.4-81684\~Ubuntu\~quantal_i386.deb Getting following errors (Reading database ... 226237 files and directories currently installed.) Preparing to replace virtualbox-4.2 4.2.4-81684~Ubuntu~quantal (using virtualbox-4.2_4.2.4-81684~Ubuntu~quantal_i386.deb) ... Unpacking replacement virtualbox-4.2 ... dpkg: dependency problems prevent configuration of virtualbox-4.2: virtualbox-4.2 depends on libc6 (>= 2.15); however: Version of libc6 on system is 2.13-20ubuntu5. virtualbox-4.2 depends on libqtcore4 (>= 4:4.8.0); however: Version of libqtcore4 on system is 4:4.7.4-0ubuntu8.1. virtualbox-4.2 depends on libqtgui4 (>= 4:4.8.0); however: Version of libqtgui4 on system is 4:4.7.4-0ubuntu8.1. dpkg: error processing virtualbox-4.2 (--install): dependency problems - leaving unconfigured Processing triggers for ureadahead ... Processing triggers for shared-mime-info ... How to solve it?

    Read the article

  • Modifying value of "Rating" column within Explorer for arbitrary file types

    - by Fake Name
    Basically, I have a large body of assorted media (text, images, flash files, archives, folders, etc...) and I'm attempting to organize it. Windows Explorer has a rating column, but there seems to be no way to modify the rating of the files short of opening them in their type-specific software (e.g. Media player, or Photo viewer). However, this does not work when the file is of an unsupported type (.rar, .swf ...), or a directory. I'd be more than willing to consider a file-manager replacement (I've alreadly looked at quite a few, Directory Opus, Total Commander, etc...), or even a solution that stores the rating metadata in a hidden file in each folder, or a separate database. The one real critical requirement is the ability to sort by rating, and being filetype-agnostic. Basically, is there any way to categorize a large collection of assorted files by rating that will work with any file type, including directories? - Ideally, there would be an easy way to add arbitrary columns to windows explorer, and edit them directly. However, there seems to be no way to do this. The rating column is the next best thing.

    Read the article

  • How to disable my laptop's defective keyboard?

    - by Kolink
    I have an Alienware M17x R2, and after a couple years of use I started having problems with the keyboard: Intermittently, and without warning or apparent cause (even if I'm not touching the computer), the S key (and more recently the D key) will start firing incessant signals until I hit the offending key. I've been using a USB keyboard, which is conveniently exactly the right size to fit over the built-in keyboard without touching any buttons. However, even as I type the defective keyboard will fire its stream of signals. I have contacted Dell about this, twice in fact. The first time, I was just bluntly told that they don't ship replacement keyboards. The second time I was told that they did, but they were out of stock and they would contact me when they were in stock again. They haven't contacted me since. I can't seem to work out which device to disable in the device manager. Here's a screenshot of what I have: None of the keyboard devices have "Disable" in their context menus, only "Uninstall"... so you'll understand if I'm hesitant to try anything myself. Any advice on how to fix this?

    Read the article

  • visually documenting web server configuration and infrastructure

    - by Alex Ciarlillo
    I have just finished a large re-organization and update of our institutions web server(s). This server hosts 3 virtual hosts, 3-4 blogs, 2 wikis, some legacy static HTML pages, and many hosted documents (PDF, .jpg, .xls). I have organized the site into a structure of something like: /var/www/sites/vhost1, vhost2, vhost3 .../wordpress/blogX .../mediawiki/wikiX Data is in a seperate directory structure so I can run a cron task over it to make sure it is all writeable and such. I then symlink to these data directories for each application. /var/www/data/vhost1, vhost2, vhost3 .../wordpress/blogX/uploads .../mediawiki/wikiX/images All Apache configs are in /etc/httpd/conf.d/vhosts.d/vhost1,2,3.conf On top of this there is also a testing server which mirrors this setup. Once changes are fully tested, they are rsynced down to the live server. All the wordpress installs and mediawiki installs are straight form SVN and updates are done by switching branches or "svn up". So my question is how can I best document to share with a) co-workers, b) possible future replacement, c) myself 6 months from now. Obviously I can make a wiki page, excel document, whatever and fill it with text, but I am looking for a more visual representation that I can use to explain the architecture to less-technical people. Ideally it would be awesome if this visual representation could then be expanded to get more technical details.

    Read the article

< Previous Page | 43 44 45 46 47 48 49 50 51 52 53 54  | Next Page >