Search Results

Search found 1470 results on 59 pages for 'suspend resume'.

Page 48/59 | < Previous Page | 44 45 46 47 48 49 50 51 52 53 54 55  | Next Page >

  • SQL Server 2008 R2 mirroring failing

    - by andriusn
    I have two Windows 2008 R2 (Amazon EC2) instances running SQL Server 2008 R2. I use 9TB striped disks (9x1TB EBS volumes) for storage. One server is running as principal and second one as mirror. Both started from the same image, database and tlog files located on striped disk. Mirror server failed 3 times in last 2 months with errors: EventID 823 The operating system returned error 2(The system cannot find the file specified.) to SQL Server during a write at offset 0x00000048058a00 in file 'D:\TLogs***_log.ldf'. Additional messages in the SQL Server error log and system event log may provide more detail. This is a severe system-level error condition that threatens database integrity and must be corrected immediately. Complete a full database consistency check (DBCC CHECKDB). This error can be caused by many factors; for more information, see SQL Server Books Online. and EventID 1454 Database mirroring will be suspended. Server instance 'xxxxxxxxxx' encountered error 823, state 6, severity 24 when it was acting as a mirroring partner for database '***'. The database mirroring partners might try to recover automatically from the error and resume the mirroring session. For more information, view the error log for additional error messages. followed by EventID 19019 The MSSQLSERVER service terminated unexpectedly. After this rebooting instance is necessary to restore mirroring. First two times I thought it was hardware related (striped disk failure) and relaunched instance on new hardware. But the issue is back after few weeks again. It only affects mirror instances. Any help would be really appreciated. Thanks.

    Read the article

  • Win XP error 0x80041003 using GetObject/winmgmts

    - by John Lewis
    My computer is called "neil" and I want to set some values using WMI in vbScript. I adapetd the script below from one supplied by Microsoft. When I run it in my browser I get Error Type: (0x80041003) /dressage/30/pdf2.asp, line 8 I suspect it is some registry/security setting. Any advice? John Lewis FULL SCRIPT call Print_HTML_Page("http://neil/dressage/ascii.asp", "ascii") Sub SetPDFFile(strPDFFile) Const HKEY_LOCAL_MACHINE = &H80000002 strKeyPath = "SOFTWARE\Dane Prairie Systems\Win2PDF" strComputer = "." Set objReg=GetObject( _ "winmgmts:{impersonationLevel=impersonate}!\\" & _ strComputer & "\root\default:StdRegProv") strValueName = "PDFFileName" objReg.SetExpandedStringValue HKEY_LOCAL_MACHINE,_ strKeyPath,strValueName,strPDFFile End Sub Sub Print_HTML_Page(strPathToPage, strPDFFile) SetPDFFile( strPDFFile ) Set objIE = CreateObject("InternetExplorer.Application") 'From http://www.tek-tips.com/viewthread.cfm?qid=1092473&page=5 On Error Resume Next strPrintStatus = objIE.QueryStatusWB(6) If Err.Number 0 Then MsgBox "Cannot find a printer. Operation aborted." objIE.Quit Set objIE = Nothing Exit Sub End If With objIE .visible=0 .left=200 .top=200 .height=400 .width=400 .menubar=0 .toolbar=1 .statusBar=0 .navigate strPathToPage End With 'Wait until IE has finished loading Do while objIE.busy WScript.Sleep 100 Loop On Error Goto 0 objIE.ExecWB 6,2 'Wait until IE has finished printing WScript.Sleep 2000 objIE.Quit Set objIE = Nothing End Sub

    Read the article

  • Dynamically create a text file from a C# program

    - by techstu
    Can I dynamically create a text file from a C# program, using data from a previously created xml file and text file, I have written half the code, but can't go any further please help using System; using System.IO; using System.Xml; namespace Task3 { class TextFileReader { static void Main(string[] args) { String strn=" ", strsn=String.Empty; XmlTextReader reader = new XmlTextReader("my.xml"); while (reader.Read()) { switch (reader.NodeType) { case XmlNodeType.Element: // The node is an element. if (reader.HasAttributes) { strn = reader.GetAttribute(0); strsn = reader.GetAttribute(1); int counter = 0; string line; // Read the file and display it line by line. System.IO.StreamReader file = new System.IO.StreamReader("read_file.txt"); string ch, ch1; while ((line = file.ReadLine()) != null) { if (line.Substring(0, 1).Equals("%")) { int a = line.IndexOf('%'); int b = line.LastIndexOf('%'); ch = line.Substring(a + 1, b - 1); ch1 = line.Substring(a, b+1); if (ch == "name") { string test = line.Replace(ch1, strn); Console.WriteLine(test); } else if (ch == "sirname") { string test = line.Replace(ch1, strsn); Console.WriteLine(test); } } else { Console.WriteLine(line); } counter++; } file.Close(); } break; } } // Suspend the screen. Console.ReadLine(); } } } the xml file from which i am reading is: <?xml version="1.0" encoding="utf-8" ?> - <Workflow> <User UserName="pqr" Sirname="sbd" /> <User UserName="abc" Sirname="xyz" /> </Workflow> and the text file is: hi this is me %sirname% %name% but this is not wat i want..please help

    Read the article

  • Access Windows Boot Manager selector when timeout is set to 0?

    - by Kyle Cronin
    I've installed Wubi onto a Windows Vista computer. I've also set the boot timeout to 0: bcdedit /timeout 0 However, now I can't figure out how to get the menu to come up at all! I read on the internets that I had to hold F8 or space when starting up, but they doesn't seem to do anything. Is there a different key or setting I've overlooked? The computer itself is a Dell that's a few months old. The keyboard is USB, but I don't think that's the problem as I can get into the BIOS just fine. Maybe I'm doing it wrong? Am I supposed to hold the keys or rapidly tap them (I've tried both)? If it helps, here's the output from bcdedit: C:\Windows\system32>bcdedit Windows Boot Manager -------------------- identifier {bootmgr} device partition=C: description Windows Boot Manager locale en-US inherit {globalsettings} default {current} resumeobject {5460d9d2-d391-11dc-9d9f-aba67a8797c5} displayorder {current} {e2484fe7-5e97-11de-84d4-0024e8074422} toolsdisplayorder {memdiag} timeout 0 resume No Windows Boot Loader ------------------- identifier {current} device partition=C: path \Windows\system32\winload.exe description Windows Vista locale en-US inherit {bootloadersettings} recoverysequence {572bcd55-ffa7-11d9-aae0-0007e994107d} recoveryenabled Yes osdevice partition=C: systemroot \Windows resumeobject {5460d9d2-d391-11dc-9d9f-aba67a8797c5} nx OptIn Real-mode Boot Sector --------------------- identifier {e2484fe7-5e97-11de-84d4-0024e8074422} device partition=C: path \ubuntu\winboot\wubildr.mbr description Ubuntu

    Read the article

  • Prevent Win7 from resuming from hibernation

    - by Tigraine
    Hi Guys, I am running Win7 x64 on my machine and everything is perfect. I actually never turn off my PC completely but rather I always put it into hibernation mode for fast resume once I get back. Hibernation works like a charm, but once every 50 or 100 hibernations something goes wrong and the machine reboots. After that I usually have to reset the system clock in BIOS and Windows is starting up from the hibernation image that somehow got saved to disk (that's really cool). But: This hibernation image recovery is awfully slow, once the machine is up again it takes almost 2 minutes for it to not feel sluggish any more (I suspect this is due to pagefaults on all memory access). I'm looking for a way to tell Windows to NOT recover from the crash but rather just boot fresh, discarding the hibernation since it's faster to just reboot rather than wait for 3+ minutes for the machine to get it's act together. I do see the normal bios startup and also the windows boot afterwards, but hitting F8 like crazy doesn't do anything. In Win2000 and XP a Menu would come up asking me how I do want to boot, but I can't find it on Win7. Thanks in advance!

    Read the article

  • Disable Painting of the VScrollbar in a System.Windows.Forms.RichTextBox

    - by SchlaWiener
    I have a custom control inherited from RichTextBox. This control has the ability to "disable" rich text editing. I achive this by just setting the Rtf property to the text property during the TextChanged event. this is how my code looks like: private bool lockTextChanged; void RichTextBox_TextChanged(object sender, EventArgs e) { // prevent StackOverflowException if (lockTextChanged) return; // remember current position int rtbstart = rtb.SelectionStart; int len = rtb.SelectionLength; // prevent painting rtb.SuspendLayout(); // set the text property to remove the entire formatting. lockTextChanged = true; rtb.Text = rtb.Text; rtb.Select(rtbstart, len); lockTextChanged = false; rtb.ResumeLayout(true); } That worked well. However in a large text with like 200 lines the controls jitters (you see the first lines of text for the wink). To prevent that from happening I filter the WM_PAINT between SuspendLayout() and ResumeLayout() private bool layoutSuspended; public new void SuspendLayout() { layoutSuspended = true; base.SuspendLayout(); } public new void ResumeLayout() { layoutSuspended = false; base.ResumeLayout(); } public new void ResumeLayout(bool performLayout) { layoutSuspended = false; base.ResumeLayout(performLayout); } private const int WM_PAINT = 0x000F; protected override void WndProc(ref System.Windows.Forms.Message m) { if (!(m.Msg == WM_PAINT && layoutSuspended)) base.WndProc(ref m); } that did the trick, the RichTextBox isn't jittering anymoe. That's what I wanted to achive, except one thing: The scrollbar is still jittering everytime I type text to my control. Now my question: Does anyone have a clue for me how to prevent the scrollbar from redrawing during Suspend/Resume Layout?

    Read the article

  • Java process is not terminating after starting an external process

    - by tangens
    On Windows I've started a program "async.cmd" with a ProcessBuilder like this: ProcessBuilder processBuilder = new ProcessBuilder( "async.cmd" ); processBuilder.redirectErrorStream( true ); processBuilder.start(); Then I read the output of the process in a separate thread like this: byte[] buffer = new byte[ 8192 ]; while( !interrupted() ) { int available = m_inputStream.available(); if( available == 0 ) { Thread.sleep( 100 ); continue; } int len = Math.min( buffer.length, available ); len = m_inputStream.read( buffer, 0, len ); if( len == -1 ) { throw new CX_InternalError(); } String outString = new String( buffer, 0, len ); m_output.append( outString ); } Now it happened that the content of the file "async.cmd" was this: REM start a command window start cmd /k The process that started this extenal program terminated (process.waitFor() returned the exit value). Then I sent an readerThread.interrupt() to the reader thread and the thread terminated, too. But there was still a thread running that wasn't terminating. This thread kept my java application running even if it exited its main method. With the debugger (eclipse) I wasn't able to suspend this thread. After I quit the opened command window, my java program exited, too. Question How can I quit my java program while the command window stays open?

    Read the article

  • Ubuntu 64bit Xen DomU Issues after upgrade from Karmic to Lucid

    - by Shoaibi
    I was upgrading my servers today and it all went fine except the last machine which has the following issues: [Resolved using http://www.ndchost.com/wiki/server-administration/upgrade-ubuntu-pre-10.04#post-1004-upgradefinal-steps] No login prompt on console Done. Begin: Mounting root file system... ... Begin: Running /scripts/local-top ... Done. [ 0.545705] blkfront: xvda: barriers enabled [ 0.546949] xvda: xvda1 [ 0.549961] blkfront: xvde: barriers enabled [ 0.550619] xvde: xvde1 xvde2 Begin: Running /scripts/local-premount ... Done. [ 0.870385] kjournald starting. Commit interval 5 seconds [ 0.870449] EXT3-fs: mounted filesystem with ordered data mode. Begin: Running /scripts/local-bottom ... Done. Done. Begin: Running /scripts/init-bottom ... Done. Also tried by pressing ENTER and CTRL+C many times, no use. Resolved: [/tmp was mounted as noexec, changing that fix it]: I get errors when i try to re-install udev in single user mode: Unpacking replacement udev ... Processing triggers for ureadahead ... ureadahead will be reprofiled on next reboot Processing triggers for man-db ... Setting up udev (151-12.1) ... udev start/running, process 1003 Removing `local diversion of /sbin/udevadm to /sbin/udevadm.upgrade' update-initramfs: deferring update (trigger activated) Processing triggers for initramfs-tools ... update-initramfs: Generating /boot/initrd.img-2.6.32-25-server /usr/sbin/mkinitramfs: 329: /tmp/mkinitramfs_yuuTSc/scripts/local-premount/fixrtc: Permission denied /usr/sbin/mkinitramfs: 329: /tmp/mkinitramfs_yuuTSc/scripts/local-premount/ntfs_3g: Permission denied /usr/sbin/mkinitramfs: 329: /tmp/mkinitramfs_yuuTSc/scripts/local-premount/resume: Permission denied /usr/sbin/mkinitramfs: 329: /tmp/mkinitramfs_yuuTSc/scripts/nfs-top/udev: Permission denied /usr/sbin/mkinitramfs: 329: /tmp/mkinitramfs_yuuTSc/scripts/panic/console_setup: Permission denied /usr/sbin/mkinitramfs: 329: /tmp/mkinitramfs_yuuTSc/scripts/init-top/all_generic_ide: Permission denied /usr/sbin/mkinitramfs: 329: /tmp/mkinitramfs_yuuTSc/scripts/init-top/blacklist: Permission denied /usr/sbin/mkinitramfs: 329: /tmp/mkinitramfs_yuuTSc/scripts/init-top/udev: Permission denied /usr/sbin/mkinitramfs: 329: /tmp/mkinitramfs_yuuTSc/scripts/init-bottom/udev: Permission denied /usr/sbin/mkinitramfs: 329: /tmp/mkinitramfs_yuuTSc/scripts/local-bottom/ntfs_3g: Permission denied

    Read the article

  • how to back up data from a machine that keeps hanging

    - by Amit Phatarphekar
    Hello - I have a storage server running opensolaris. But lately its been acting up - it hangs at random times due to some SCSI/ATA related error messages. I've tried to fix it without any progress, so I'm giving up now. The machine keeps hanging every 30 minutes or 1 hr ...sometimes after 4 hrs. Its very unpredictable. So I've decided to just reformat the storage server and start from scratch...maybe I'll just not use solaris and install something else, since the errors are related to solaris running on ATA HDD or something. Question - Before I reformat it, I want to back up some of the important data on it. Like it has a VM with 200 GB disk files, it has a whole bunch of ISOs stored on it etc etc. I'm using a simple scp to copy the files over to a different machine. My issue is that, because the machine hangs....sometimes my file copy is incomplete and I have to start all over again. Lets say I'm trying to copy a 200GB file which takes like 4 hrs....IF the machine hangs before the whole file i copied over...I have to recopy the file from scratch. Is there a solution to copy the files over such that if the machine hangs or network goes down..the copying can resume from where it left off? - like if 50 GB of a 200GB file was copied and machine hung....next time, it'll just continue to copy rest of the amount, instead of starting all over again. Thanks Amit

    Read the article

  • Cisco Configuration backup with Windows Script.

    - by Jeff
    We have a client with a lot of Cisco Devices and we would like to automate the backups of these devices through telnet. We have both 2003 and 2008 servers and ideally use tftp to back it up. I wrote this: Set WshShell = WScript.CreateObject("WScript.Shell") Dim fso Set fso = CreateObject("Scripting.FileSystemObject") Dim ciscoList ciscoList = "D:\Scripts\SwitchList.txt" Set theSwitchList = fso.OpenTextFile(ciscoList, 1) Do While theSwitchList.AtEndOfStream <> True cisco = theSwitchList.ReadLine Run "cmd.exe" SendKeys "telnet " SendKeys cisco SendKeys "{ENTER}" SendKeys "USERNAME" SendKeys "{ENTER}" SendKeys "PASSWORD" SendKeys "{ENTER}" SendKeys "en" SendKeys "{ENTER}" SendKeys "PASSWORD" SendKeys "{ENTER}" SendKeys "copy startup-config tftp{ENTER}" SendKeys "(TFTP IP){ENTER}" SendKeys "FileName.txt{ENTER}" SendKeys "exit{ENTER}" 'close telnet session' SendKeys "{ENTER}" 'get command prompt back SendKeys "{ENTER}" SendKeys "exit{ENTER}" 'close cmd.exe On Error Resume Next WScript.Sleep 3000 Loop Sub SendKeys(s) WshShell.SendKeys s WScript.Sleep 300 End Sub Sub Run(command) WshShell.Run command WScript.Sleep 100 WshShell.AppActivate command WScript.Sleep 300 End Sub But the problem with this is the sendkeys are sent to the console session, I'm trying to find a solution that would not require a user to be logged in. Does anyone have any ideas? I have some knowlage of VBS, PowerShell and a pretty good grasp on batching.

    Read the article

  • MySQL Master - Master Broken

    - by Recc
    I've Inherited a Mysql master master system, I've noticed the second master (lets call it slave from now on as it's running on a 'slave' machine) stopped getting its db's updated. I saw that Master: Slave_IO_Running: Yes Slave_SQL_Running: Yes Slave: (with an error I truncated) Slave_IO_Running: Yes Slave_SQL_Running: No Last_Errno: 1062 Last_Error: Error 'Duplicate entry '3' for key 'PRIMARY'' on [...] I don't know what caused it to process considering we cant get duplicate there. What's important is to resume normal operations; Right now I've stop slave; on the Master and stop slave; on the Slave because I saw that if I change records on the Slave the changes Do Get Propagated to Master which is in active use. How do I: Force sync EVERYTHING from master to slave without affecting data on master? Then hopefully have slave pickup replication as usual? UPDATE OK I Tried deleting all tables on slave then it complained in that error section that the 'table' doesnt exist. So i made a no data dump of Master, and made sure I have only empty tables in Secondary (slave). I start slave; on slave BUT now it's complaining about bloody alter table statements for instance: Last_Errno: 1060 Last_Error: Error 'Duplicate column name [...] Query: 'ALTER TABLE [...] How to skip the fracking alter statements I just want to replicate the bloody data and be done with it, my tables have the lates changes already FFS and now its complaining about changes made after the replication seized weeks ago How do I reset the log or something? OUTSTANDING Why would this start happening? The "Secondary" is propagating to "Primary". "Primary" is not propagating to "Secondary". But any fixes I tried to do left it in the same state Yes-Yes Yes-No with same Last_Error. I think around that time the server was taken off the network, could that confuse MySQL in some way?

    Read the article

  • Memory Leak Looping cfmodule inside cffunction

    - by orangepips
    Hoping someone else can confirm or tell me what I'm doing wrong. I am able to consistently reproduce an OOM running by calling the file oom.cfm (shown below). Using jconsole I am able to see the request consumes memory and never releases it until complete. The issue appears to be calling <cfmodule> inside of <cffunction>, where if I comment out the <cfmodule> call things are garbage collected while the request is running. ColdFusion version: 9,0,1,274733 JVM Arguments java.home=C:/Program Files/Java/jdk1.6.0_18 java.args=-server -Xms768m -Xmx768m -Dsun.io.useCanonCaches=false -XX:MaxPermSize=512m -XX:+UseParallelGC -Xbatch -Dcoldfusion.rootDir={application.home}/ -Djava.security.policy={application.home}/servers/41ep8/cfusion.ear/cfusion.war/WEB-INF/cfusion/lib/coldfusion.policy -Djava.security.auth.policy={application.home}/servers/41ep8/cfusion.ear/cfusion.war/WEB-INF/cfusion/lib/neo_jaas.policy -Xdebug -Xrunjdwp:transport=dt_socket,server=y,suspend=n,address=56033 Test Case oom.cfm (this calls template.cfm below) <cffunction name="fun" output="false" access="public" returntype="any" hint=""> <cfset var local = structNew()/> <!--- comment out cfmodule and no OOM ---> <cfmodule template="template.cfm"> </cffunction> <cfset size = 1000 * 200> <cfloop from="1" to="#size#" index="idx"> <cfset fun()> <cfif NOT idx mod 1000> <cflog file="se-err" text="#idx# of #size#"> </cfif> </cfloop> template.cfm <!--- I am empty! --->

    Read the article

  • Write Null/Nothing value with Databinding

    - by clawson
    I have extended a MaskedTextBox component to add some functionality. The text property of the extended MaskedTextBox is bound to a DateTime? property and the format of binding is set to a time format of "HH:mm:ss" (i.e. 24hr time). So that this masked text box will capture the display a time. The extra functionality I have added is to make the component readonly unless the component is double clicked or the enter button is pressed (the back color of the control helps to inform the users if the component is locked/readonly or not). When the enter button is pressed I also suspend the bindings so that bound data is updated the users input won't be lost. The information is then written back to the value and databindings resumed when the user presses the enter key again. This all works fine up to here, with values written and displayed as would be expected. However, I also want to write the null or nothing value to the DateTime? property if the user hasn't entered any text (or invalid text but let's just stick with no text) when enter key is pressed to submit the new value. Unlike with other valid entries in the MaskedTextBox, with no text entered when i execute: Me.DataBindings("Text").WriteValue() (when 'locking' the MaskedTextBox) it then branches to the bound properties Get method as I step into each line of code in the debugger (as opposed to the Set method with other valid entries) How can I write this null/nothing/"" value to the DateTime? property when no text "" is entered into the MaskedTextBox? Thanks for the help!

    Read the article

  • Scripted forwarding for Outlook 2003

    - by John Gardeniers
    We have a staff member in sales who has gone onto a 4 day week (getting ready for retirement), so each Thursday afternoon her email needs to be forwarded to another user and each Friday afternoon it needs to be set back. I'm using the VBS script below to do this, run via the Task Scheduler. Although the script appears to do it's job, based on what I see when I view the user's Exchange settings, Exchange doesn't always recognise that the setting has changed. e.g. Last Thursday the forwarding was a enabled and worked correctly. On Friday the script did it's thing to clear the forwarding but Exchange continued to forward messages all weekend. I found that I can force Exchange to honour the changed setting be merely opening and closing the user's properties in ADUC. Of course I don't want to have to do that. Is there a non-manual way I can have Exchange read and honour the setting? The script (VBS): ' Call this script with the following parameters: ' ' SrcUser - The logon ID of the suer who's account is to be modified ' DstUser - The logon account of the person to who mail is to be forwarded ' Use "reset" to clear the email forwarding SrcUser = WScript.Arguments.Item(0) DstUser = WScript.Arguments.Item(1) SourceUser = SearchDistinguishedName(SrcUser) 'The user login name Set objUser = GetObject("LDAP://" & SourceUser) If DstUser = "reset" then objUser.PutEx 1, "altRecipient", "" Else ForwardTo = SearchDistinguishedName(DstUser)' The contact common name objUser.Put "AltRecipient", ForwardTo End If objUser.SetInfo Public Function SearchDistinguishedName(ByVal vSAN) Dim oRootDSE, oConnection, oCommand, oRecordSet Set oRootDSE = GetObject("LDAP://rootDSE") Set oConnection = CreateObject("ADODB.Connection") oConnection.Open "Provider=ADsDSOObject;" Set oCommand = CreateObject("ADODB.Command") oCommand.ActiveConnection = oConnection oCommand.CommandText = "<LDAP://" & oRootDSE.get("defaultNamingContext") & ">;(&(objectCategory=User)(samAccountName=" & vSAN & "));distinguishedName;subtree" Set oRecordSet = oCommand.Execute On Error Resume Next SearchDistinguishedName = oRecordSet.Fields("DistinguishedName") On Error GoTo 0 oConnection.Close Set oRecordSet = Nothing Set oCommand = Nothing Set oConnection = Nothing Set oRootDSE = Nothing End Function

    Read the article

  • MySQL consuming all system memory on INSERT ... SELECT

    - by siete
    The mysql daemon is getting killed because Linux is reaching out of memory: Oct 24 07:41:23 <hostname> kernel: [82297.673701] Out of memory: kill process 13816 (mysqld) score 1839626 or a child There is a link with some workaround on this. That only happen when executing a query INSERT ... SELECT with a very huge resulset. MySQLTuner script displays that maximum theorical memory is less than 8GB, but top and munim shows that is getting over all RAM and swap available: [--] Total buffers: 560.0M global + 72.2M per thread (100 max threads) [OK] Maximum possible memory usage: 7.6G (43% of installed RAM) I'm tried to tune some options with not results, there are the relevant ones: skip-locking max_connections = 100 key_buffer_size = 512M max_allowed_packet = 32M table_open_cache = 2000 open_files_limit = 3000 sort_buffer_size = 16M read_buffer_size = 16M read_rnd_buffer_size = 8M myisam_sort_buffer_size = 64M thread_cache_size = 4 query_cache_size = 16M query_cache_limit = 2M thread_concurrency = 4 join_buffer_size = 32M tmp_table_size = 32M max_heap_table_size = 32M query_cache_limit = 8M bulk_insert_buffer_size = 64M myisam_max_sort_file_size = 50GB myisam_mmap_size = 10GB And there is a system resume: OS: Linux Debian "Squeeze" 6.0.8 (upgraded yesterday) RAM: 18GB Swap: 18GB MySQL: 5.1.72-2 (official Debain release) At this moment, update or change OS or MySQL version is not possible, there is any option that can help and i missed? Sorry by my english, and thank you in advance! Edit: I'm only using MyISAM tables, and cannot change to InnoDB.

    Read the article

  • How to get rid of Windows XP Pro Blue pop up screen

    - by LISA
    Windows XP user-home edition 36 bit. One day I woke to see a blue pop up screen from Microsoft Windows XP Pro. I have not installed anything new myself. The 'add on' pop up always comes on when I open up mozilla to surf the net. I always just close it out to not install anything. I then woke to have colored tabs, the new download status bar at the bottom and this pop up window that asks me to retype two words spaced, a timer of two minutes starts and states if no word put in system will shut off. I have let it run down more than a few times and it does not shut down. No other options to choose from. If I misspell with a lot of letters it tells me I did so, but if I can't read a few letters I guess at it although it is not and it lets me resume what I am doing. This window pops up every single minute no matter what I am doing. Please help, I'm really annoyed with this. I have searched the net all over and don't quit know what to look for anymore

    Read the article

  • Linux - preventing an application from failing due to lack of disk space [migrated]

    - by Jernej
    Due to an unpredicted scenario I am currently in need of finding a solution to the fact that an application (which I do not wish to kill) is slowly hogging the entire disk space. To give more context I have an application in Python that uses multiprocessing.Pool to start 5 threads. Each thread writes some data to its own file. The program is running on Linux and I do not have root access to the machine. The program is CPU intensive and has been running for months. It still has a few days to write all the data. 40% of the data in the files is redundant and can be removed after a quick test. The system on which the program is running only has 30GB of remaining disk space and at the current rate of work it will surely be hogged before the program finishes. Given the above points I see the following solutions with respective problems Given that the process number i is writing to file_i, is it safe to move file_i to an external location? Will the OS simply create a new instance of file_i and write to it? I assume moving the file would remove it and the process would end up writing to a "dead" file? Is there a "command line" way to stop 4 of the 5 spawned workers and wait until one of them finishes and then resume their work? (I am sure one single worker thread would avoid hogging the disk) Suppose I use CTRL+Z to freeze the main process. Will this stop all the other processes spawned by multiprocessing.Pool? If yes, can I then safely edit the files as to remove the redundant lines? Given the three options that I see, would any of them work in this context? If not, is there a better way to handle this problem? I would really like to avoid the scenario in which the program crashes just few days before its finish.

    Read the article

  • How to kill tasks in Windows 7 when even Task Manager won't open or respond?

    - by endolith
    Occasionally one of my computers will get so bogged down that everything locks up, Ctrl+Alt+Del doesn't work, Task Manager won't open, or they work, but are opening so slowly that it will take hours or days to shut down other processes and regain control of the computer, etc. Is there a way to, for instance, force Task Manager to be highest priority so it always opens immediately with Ctrl+Shift+Esc even when some other process/driver is hogging the CPU? Is there some other program that can run in the background and open immediately like this? This question isn't about fixing "underlying problems". No matter how much memory you have, it's still possible for a rogue process to eat it all up and lock up the computer in page fault thrashing, hog the CPU, etc. This question is about how to take back control of the computer when that happens. Basically when these kind of lock-ups happen, I want to open some kind of task manager that pauses every other process and allows me to kill one of them, and then let everything resume so I can save my work, etc. Otherwise my only option is to hold down the power button. Antifreeze is supposed to do exactly what i want, pausing all other applications and starting a task manager to kill the offender, but in my testing, it actually does neither.

    Read the article

  • Loading an XML configuration file BEFORE the flex application loads

    - by Shahar
    Hi, We are using an XML file as an external configuration file for several parameters in our application (including default values for UI components and properties values of some service layer objects). The idea is to be able to load the XML configuration file before the flex application initializes any of its components. This is crucial because XML loading is processed a-synchronously in flex, which can potentially cause race-conditions in the application. For example: the configuration file holds the endpoint URL of a web service used to obtain data from the server. The URL resides in the XML because we want to allow our users to alter the endpoint URL according to their environment. Now because the endpoint URL is retrieved only after the XML has been completely loaded, some of the application's components might be invoking operations on this web service before it is initialized with the correct endpoint. The trivial solution would have been to suspend the initialization of the application until the complete event is dispatched by the loader. But it appears that this solution is far from being trivial. I haven't found a single solution that allows me to load the XML before any other object in the application. Can anyone advice or comment on this matter? Regards, Shahar

    Read the article

  • Is it possible to download extremely large files intelligently or in parts via SSH from Linux to Windows?

    - by Andrew
    I have a ~35 GB file on a remote Linux Ubuntu server. Locally, I am running Windows XP, so I am connecting to the remote Linux server using SSH (specifically, I am using a Windows program called SSH Secure Shell Client version 3.3.2). Although my broadband internet connection is quite good, my download of the large file often fails with a Connection Lost error message. I am not sure, but I think that it fails because perhaps my internet connection goes out for a second or two every several hours. Since the file is so large, downloading it may take 4.5 to 5 hours, and perhaps the internet connection goes out for a second or two during that long time. I think this because I have successfully downloaded files of this size using the same internet connection and the same SSH software on the same computer. In other words, sometimes I get lucky and the download finishes before the internet connection drops for a second. Is there any way that I can download the file in an intelligent way -- whereby the operating system or software "knows" where it left off and can resume from the last point if a break in the internet connection occurs? Perhaps it is possible to download the file in sections? Although I do not know if I can conveniently split my file into multiple files -- I think this would be very difficult, since the file is binary and is not human-readable. As it is now, if the entire ~35 GB file download doesn't finish before the break in the connection, then I have to start the download over and overwrite the ~5-20 GB chunk that was downloaded locally so far. Do you have any advice? Thanks.

    Read the article

  • Rebuilding LVM after RAID recovery

    - by Xiong Chiamiov
    I have 4 disks RAID-5ed to create md0, and another 4 disks RAID-5ed to create md1. These are then combined via LVM to create one partition. There was a power outage while I was gone, and when I got back, it looked like one of the disks in md1 was out of sync - mdadm kept claiming that it only could find 3 of the 4 drives. The only thing I could do to get anything to happen was to use mdadm --create on those four disks, then let it rebuild the array. This seemed like a bad idea to me, but none of the stuff I had was critical (although it'd take a while to get it all back), and a thread somewhere claimed that this would fix things. If this trashed all of my data, then I suppose you can stop reading and just tell me that. After waiting four hours for the array to rebuild, md1 looked fine (I guess), but the lvm was complaining about not being able to find a device with the correct UUID, presumably because md1 changed UUIDs. I used the pvcreate and vgcfgrestore commands as documented here. Attempting to run an lvchange -a y on it, however, gives me a resume ioctl failed message. Is there any hope for me to recover my data, or have I completely mucked it up?

    Read the article

  • Move a screen session back to its original PID

    - by cron410
    Installed McMyAdmin (minecraft manager) on Ubuntu 12.04 32 bit. Wrote my own service to start McMyAdmin (.net app running in Mono) in its own screen session, and be able to inject proper McMyAdmin commands into that session with the init.d script. Its been running great! Today, I decided to start installing a Source dedicated server (counterstrike pro mod) I determine its going to be a long download process so I quit the process and fire up a fresh screen session called "source". I paste the command in, but it has a space at the begining and bash complains of ignoring semaphores or some such. I detach and reattach the session. Its sliding like butter. I ctrl+a-d out of the session and start exploring the new folder structure and figure out where I need to place a symbolic link. I go to resume that screen and this is what I see: $screen -r source There are several suitable screens on 20091.source (12/02/12 22:59:53) (Detached) 19972.source (12/02/12 22:57:31) (Detached) 917.minecraft (11/30/12 15:30:37) (Attached) It appears I am connected to the minecraft screen?!?!?! So I attach to the other screens one at a time. minecraft is running in 19972.source and sourceds is running in 20091.source So how the hell did I move the minecraft process to another session called source and my main terminal is now "attached" to the minecraft screen? more: I just used exit to quit the putty session, then logged back in, its still the same. did that 3 more times and now the minecraft screen is gone and everything is acting as it should except, of course, for the session name and start time of the "new" minecraft screen. Should I just submit this as a bug for GNU screen?

    Read the article

  • GPO startup script not copying files

    - by marcwenger
    I created a GPO startup script to execute for computers in a specific AD container. The script takes a file from the AD netlogon share and places it on a directory on the computer. Given the right permissions (ie: myself) can execute the script just fine and the file copies. But it doesn't work on startup - the file does not copy over from the AD server. The startup script should run as localsystem (am I right?). So the question is why do the files not copy on startup? Could it be because of: Is it permissions of the local system user? Reading the registry is problematic on startup? Obtaining files from the AD netlogon folder is problematic on startup? Am I missing it completely? My test machine does have the registry key and local directories as described in the script. I myself have standard user permissions on the test machine. AD server is Windows 2008, test client is Windows XP SP3 (and soon to be Windows 7, which I assume permissions issues will be inevitable) Dim wShell, fso, oraHome, tnsHome, key, srcDir Set wShell = WScript.CreateObject("WScript.Shell") Set fso = CreateObject("Scripting.FileSystemObject") key = "HKLM\Software\Oracle\Oracle_Home" On Error Resume Next orahome = wShell.RegRead(key) If err.Number = 0 Then tnsHome = oraHome + "\" + "network\admin\" srcDir = wShell.ExpandEnvironmentStrings("%logonserver%") + "\netlogon\UpdatedFiles\" fso.CopyFile srcDir + "file1.ext", tnsHome, true End If Side note: To ensure that the script is properly deployed, I purposely put some errors in the script, and on the next startup the error message appeared. So I know the GPO is deployed properly.

    Read the article

  • Configure static IPv6 on Ubuntu

    - by Charles Offenbacher
    I'm trying to configure IPv6 on a dedicated Ubuntu server. My provider gave me a "/64" (whatever that is - I'm still confused) of IPv6 addresses. However, when I try to use them, I can't ping anything. What do I do? :( # ping6 ipv6.google.com PING ipv6.google.com(vx-in-x63.1e100.net) 56 data bytes From fe80::219:d1ff:fefb:42d8 icmp_seq=1 Destination unreachable: Address unreachable From fe80::219:d1ff:fefb:42d8 icmp_seq=2 Destination unreachable: Address unreachable From fe80::219:d1ff:fefb:42d8 icmp_seq=3 Destination unreachable: Address unreachable --- ipv6.google.com ping statistics --- 3 packets transmitted, 0 received, +3 errors, 100% packet loss, time 2014ms # tracepath6 ipv6.google.com 1?: [LOCALHOST] 0.025ms pmtu 1500 1: fe80::219:d1ff:fefb:42d8%eth0 2000.022ms !H Resume: pmtu 1500 # cat /etc/network/interfaces # The loopback network interface auto lo iface lo inet loopback # The primary network interface auto eth0 iface eth0 inet static address 64.***.***.*** netmask 255.255.255.248 gateway 64.***.***.*** iface eth0 inet6 static pre-up modprobe ipv6 address 2607:F878:1:***::1 netmask 64 gateway 2607:F878:1:***(same as address)::1 # ifconfig eth0 Link encap:Ethernet HWaddr 00:19:d1:fb:42:d8 inet addr:64.***.***.*** Bcast:64.***.***.*** Mask:255.255.255.248 inet6 addr: fe80::219:d1ff:fefb:42d8/64 Scope:Link inet6 addr: 2607:f878:1:***::1/64 Scope:Global UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:52451 errors:0 dropped:0 overruns:0 frame:0 TX packets:39729 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:6817761 (6.8 MB) TX bytes:6153835 (6.1 MB) Interrupt:41 Base address:0xc000 lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:166 errors:0 dropped:0 overruns:0 frame:0 TX packets:166 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:31714 (31.7 KB) TX bytes:31714 (31.7 KB)

    Read the article

  • Is there any way to customize the Windows 7 taskbar auto-hide behavior? Delay activation? Timer?

    - by calbar
    I'm becoming increasingly frustrated with the way Windows 7 handles showing a hidden taskbar. It's incredibly over-eager to pop out and obscure what I'm really trying to interact with, requiring me to move the mouse away, wait for it to auto-hide again, then resume what I was doing but more deliberately. After closely examining the behavior, it appears that a hidden taskbar "peeks out" from the edge by 2 or 3 pixels, and slowly moving your mouse into this area activates it; you don't even need to touch the edge of the screen. I would love it if there was a way to customize or change this behavior. Ideally, the taskbar would only pop out if you are actively "pushing" the edge of the screen it is hidden on. So activation only occurs once you've reached the screens edge and continue to move the mouse past a customizable threshold. Alternatively, a simple activation delay would suffice as well. So only if the mouse remains in that 2-3 pixel area (a.k.a. on the taskbar) for greater than a customizable amount of time does it pop out again. This would only be a fraction of a second. Often times the cursor simply "careens" off the edge of the screen while trying to focus on something nearby. Anyway, if there are any registry settings or utilities that can achieve either of these effects, that would be great! Thanks for your help.

    Read the article

< Previous Page | 44 45 46 47 48 49 50 51 52 53 54 55  | Next Page >