Search Results

Search found 5127 results on 206 pages for 'mscorwks dll'.

Page 49/206 | < Previous Page | 45 46 47 48 49 50 51 52 53 54 55 56  | Next Page >

  • VSTS test deployment and invalid assembly culture

    - by Merlyn Morgan-Graham
    I have a DLL that I'm testing, which links to a DLL that has what I think is an invalid value for AssemblyCulture. The value is "Neutral" (notice the upper-case "N"), whereas the DLL I'm testing, and every other DLL in my project, has a value of "neutral" (because they specify AssemblyCulture("")). When I try to deploy the DLL that links to the problem DLL, I get this error in VSTS: Failed to queue test run '...': Culture is not supported. Parameter name: name Neutral is an invalid culture identifier. <Exception>System.Globalization.CultureNotFoundException: Culture is not supported. Parameter name: name Neutral is an invalid culture identifier. at System.Globalization.CultureInfo..ctor(String name, Boolean useUserOverride) at System.Globalization.CultureInfo..ctor(String name) at System.Reflection.RuntimeAssembly.GetReferencedAssemblies(RuntimeAssembly assembly) at System.Reflection.RuntimeAssembly.GetReferencedAssemblies() at Microsoft.VisualStudio.TestTools.Utility.AssemblyLoadWorker.ProcessChildren(Assembly assembly) at Microsoft.VisualStudio.TestTools.Utility.AssemblyLoadWorker.GetDependentAssemblies(String path) at Microsoft.VisualStudio.TestTools.Utility.AssemblyLoadWorker.GetDependentAssemblies(String path) at Microsoft.VisualStudio.TestTools.Utility.AssemblyLoadStrategy.GetDependentAssemblies(String path) at Microsoft.VisualStudio.TestTools.Utility.AssemblyHelper.GetDependentAssemblies(String path, DependentAssemblyOptions options, String configFile) at Microsoft.VisualStudio.TestTools.TestManagement.DeploymentManager.GetDependencies(String master, String configFile, TestRunConfiguration runConfig, DeploymentItemOrigin dependencyOrigin, List`1 dependencyDeploymentItems, Dictionary`2 missingDependentAssemblies) at Microsoft.VisualStudio.TestTools.TestManagement.DeploymentManager.DoDeployment(TestRun run, FileCopyService fileCopyService) at Microsoft.VisualStudio.TestTools.TestManagement.ControllerProxy.SetupTestRun(TestRun run, Boolean isNewTestRun, FileCopyService fileCopyService, DeploymentManager deploymentManager) at Microsoft.VisualStudio.TestTools.TestManagement.ControllerProxy.SetupRunAndListener(TestRun run, FileCopyService fileCopyService, DeploymentManager deploymentManager) at Microsoft.VisualStudio.TestTools.TestManagement.ControllerProxy.QueueTestRunWorker(Object state)</Exception> Even if I don't link to the DLL (in my VSTS wrapper test, or in the NUnit test), as soon as I add it in my GenericTest file (I'm wrapping NUnit tests), I get that exception. We don't have the source for the problem DLL, and it is also code signed, so I can't solve this by recompiling. Is there a way to skip deploying the dependencies of a DLL DeploymentItem, to fix or disable the culture check, or to work around this by convoluted means (maybe somehow embed the assembly)? Is there a way to override the value for the culture, short of hacking the DLL (and removing code signing so the hack works)? Maybe with an external manifest? Any correct solution must work without weird changes to production code. We can't deploy a hacked DLL, for example. It also must allow the DLL to be instrumented for code coverage. Additional note: I do get a linker warning when compiling the DLL under test that links to the problem DLL, but this hasn't broken anything but VSTS, and multiple versions have shipped.

    Read the article

  • Signing 3rd Party Assemblies leads to them turnign invisible!

    - by Andrew
    Hi All, I followed OJ's instructions here This allowed me to successfully breakdown, then rebuild and sign some 3rd party DLLs. Here's what I did: Dissassembled Old.dll Rebuild and signed as New.dll (using the same *.snk that my VS2005 proj is signed with) Removed all references in my proj to Old.dll and added references to New.dll Replaced 'Imports Old.dll' with 'Imports New.dll' this final step fails. VS2005 won't recognise my New.dll Any clues?

    Read the article

  • Why aren't my old DLL's running with my app pool in 32bit mode?

    - by brokkalen
    I am moving my websites from a server 2003x86 environment to a server 2008x64. the 2008 server is using iis 7.5 and the app pool I am using is configured for 32bit mode. I get an error 'Server object error 'ASP 0177 : 800401f3' Server.createObject failed.' I beleive that it is in the DLL's that all the ASP sites point to. My programmers, as usual, say it isn't code or the DLL's. Am I missing something to make these old DLL's work? By the way these sites are connecting to a SQL 2000 Database.

    Read the article

  • how to use serial port in UDK using windows DLL and DLLBind directive?

    - by Shayan Abbas
    I want to use serial port in UDK, For that purpose i use a windows DLL and DLLBind directive. I have a thread in windows DLL for serial port data recieve event. My problem is: this thread doesn't work properly. Please Help me. below is my code SerialPortDLL Code: // SerialPortDLL.cpp : Defines the exported functions for the DLL application. // #include "stdafx.h" #include "Cport.h" extern "C" { // This is an example of an exported variable //SERIALPORTDLL_API int nSerialPortDLL=0; // This is an example of an exported function. //SERIALPORTDLL_API int fnSerialPortDLL(void) //{ // return 42; //} CPort *sp; __declspec(dllexport) void Open(wchar_t* portName) { sp = new CPort(portName); //MessageBox(0,L"ha ha!!!",L"ha ha",0); //MessageBox(0,portName,L"ha ha",0); } __declspec(dllexport) void Close() { sp->Close(); MessageBox(0,L"ha ha!!!",L"ha ha",0); } __declspec(dllexport) wchar_t *GetData() { return sp->GetData(); } __declspec(dllexport) unsigned int GetDSR() { return sp->getDSR(); } __declspec(dllexport) unsigned int GetCTS() { return sp->getCTS(); } __declspec(dllexport) unsigned int GetRing() { return sp->getRing(); } } CPort class code: #include "stdafx.h" #include "CPort.h" #include "Serial.h" CSerial serial; HANDLE HandleOfThread; LONG lLastError = ERROR_SUCCESS; bool fContinue = true; HANDLE hevtOverlapped; HANDLE hevtStop; OVERLAPPED ov = {0}; //char szBuffer[101] = ""; wchar_t *szBuffer = L""; wchar_t *data = L""; DWORD WINAPI ThreadHandler( LPVOID lpParam ) { // Keep reading data, until an EOF (CTRL-Z) has been received do { MessageBox(0,L"ga ga!!!",L"ga ga",0); //Sleep(10); // Wait for an event lLastError = serial.WaitEvent(&ov); if (lLastError != ERROR_SUCCESS) { //LOG( " Unable to wait for a COM-port event" ); } // Setup array of handles in which we are interested HANDLE ahWait[2]; ahWait[0] = hevtOverlapped; ahWait[1] = hevtStop; // Wait until something happens switch (::WaitForMultipleObjects(sizeof(ahWait)/sizeof(*ahWait),ahWait,FALSE,INFINITE)) { case WAIT_OBJECT_0: { // Save event const CSerial::EEvent eEvent = serial.GetEventType(); // Handle break event if (eEvent & CSerial::EEventBreak) { //LOG( " ### BREAK received ###" ); } // Handle CTS event if (eEvent & CSerial::EEventCTS) { //LOG( " ### Clear to send %s ###", serial.GetCTS() ? "on":"off" ); } // Handle DSR event if (eEvent & CSerial::EEventDSR) { //LOG( " ### Data set ready %s ###", serial.GetDSR() ? "on":"off" ); } // Handle error event if (eEvent & CSerial::EEventError) { switch (serial.GetError()) { case CSerial::EErrorBreak: /*LOG( " Break condition" );*/ break; case CSerial::EErrorFrame: /*LOG( " Framing error" );*/ break; case CSerial::EErrorIOE: /*LOG( " IO device error" );*/ break; case CSerial::EErrorMode: /*LOG( " Unsupported mode" );*/ break; case CSerial::EErrorOverrun: /*LOG( " Buffer overrun" );*/ break; case CSerial::EErrorRxOver: /*LOG( " Input buffer overflow" );*/ break; case CSerial::EErrorParity: /*LOG( " Input parity error" );*/ break; case CSerial::EErrorTxFull: /*LOG( " Output buffer full" );*/ break; default: /*LOG( " Unknown" );*/ break; } } // Handle ring event if (eEvent & CSerial::EEventRing) { //LOG( " ### RING ###" ); } // Handle RLSD/CD event if (eEvent & CSerial::EEventRLSD) { //LOG( " ### RLSD/CD %s ###", serial.GetRLSD() ? "on" : "off" ); } // Handle data receive event if (eEvent & CSerial::EEventRecv) { // Read data, until there is nothing left DWORD dwBytesRead = 0; do { // Read data from the COM-port lLastError = serial.Read(szBuffer,33,&dwBytesRead); if (lLastError != ERROR_SUCCESS) { //LOG( "Unable to read from COM-port" ); } if( dwBytesRead == 33 && szBuffer[0]=='$' ) { // Finalize the data, so it is a valid string szBuffer[dwBytesRead] = '\0'; ////LOG( "\n%s\n", szBuffer ); data = szBuffer; } } while (dwBytesRead > 0); } } break; case WAIT_OBJECT_0+1: { // Set the continue bit to false, so we'll exit fContinue = false; } break; default: { // Something went wrong //LOG( "Error while calling WaitForMultipleObjects" ); } break; } } while (fContinue); MessageBox(0,L"kka kk!!!",L"kka ga",0); return 0; } CPort::CPort(wchar_t *portName) { // Attempt to open the serial port (COM2) //lLastError = serial.Open(_T(portName),0,0,true); lLastError = serial.Open(portName,0,0,true); if (lLastError != ERROR_SUCCESS) { //LOG( "Unable to open COM-port" ); } // Setup the serial port (115200,8N1, which is the default setting) lLastError = serial.Setup(CSerial::EBaud115200,CSerial::EData8,CSerial::EParNone,CSerial::EStop1); if (lLastError != ERROR_SUCCESS) { //LOG( "Unable to set COM-port setting" ); } // Register only for the receive event lLastError = serial.SetMask(CSerial::EEventBreak | CSerial::EEventCTS | CSerial::EEventDSR | CSerial::EEventError | CSerial::EEventRing | CSerial::EEventRLSD | CSerial::EEventRecv); if (lLastError != ERROR_SUCCESS) { //LOG( "Unable to set COM-port event mask" ); } // Use 'non-blocking' reads, because we don't know how many bytes // will be received. This is normally the most convenient mode // (and also the default mode for reading data). lLastError = serial.SetupReadTimeouts(CSerial::EReadTimeoutNonblocking); if (lLastError != ERROR_SUCCESS) { //LOG( "Unable to set COM-port read timeout" ); } // Create a handle for the overlapped operations hevtOverlapped = ::CreateEvent(0,TRUE,FALSE,0);; if (hevtOverlapped == 0) { //LOG( "Unable to create manual-reset event for overlapped I/O" ); } // Setup the overlapped structure ov.hEvent = hevtOverlapped; // Open the "STOP" handle hevtStop = ::CreateEvent(0,TRUE,FALSE,_T("Overlapped_Stop_Event")); if (hevtStop == 0) { //LOG( "Unable to create manual-reset event for stop event" ); } HandleOfThread = CreateThread( NULL, 0, ThreadHandler, 0, 0, NULL); } CPort::~CPort() { //fContinue = false; //CloseHandle( HandleOfThread ); //serial.Close(); } void CPort::Close() { fContinue = false; CloseHandle( HandleOfThread ); serial.Close(); } wchar_t *CPort::GetData() { return data; } bool CPort::getCTS() { return serial.GetCTS(); } bool CPort::getDSR() { return serial.GetDSR(); } bool CPort::getRing() { return serial.GetRing(); } Unreal Script Code: class MyPlayerController extends GamePlayerController DLLBind(SerialPortDLL); dllimport final function Open(string portName); dllimport final function Close(); dllimport final function string GetData();

    Read the article

  • Unable to register the DLL/OCX: RegSvr32 failed with exit code 0xC0000005 with Inno Setup 5.2.3

    - by robodale
    I am trying to register a COM DLL using Inno Setup in a setup package I created. During test installations on Vista, I get this error: Unable to register the DLL/OCX: RegSvr32 failed with exit code 0xC0000005 I click "Ignore" and my application appears to install, but I have to then open a command prompt (as an administrator) and then regsvr32 to install the COM DLL. Is there any way to do this automatically in Inno Setup?

    Read the article

  • How Does a COM Program Locate a .NET DLL Registered for COM Interop?

    - by Eric J.
    One customer wants to consume our .NET DLLs from VB6. They are designed to support reverse interop and all works fine... except: There are two separate VB6 programs in two different directories. It seems it's necessary to do one of: Copy the .NET DLL into both directories, or Install the .NET DLL in the GAC This is the customer's observation and also supported by the RegAsm documentation: After registering an assembly using Regasm.exe, you can install it in the global assembly cache so that it can be activated from any COM client. If the assembly is only going to be activated by a single application, you can place it in that application's directory. I'm confused on this point. First point of confusion: As far as I understand, the COM runtime locates the DLL using the Prog ID / Class ID. When I look in the registry at the Class ID entry, I see the full path to the .NET DLL in the CodeBase key. Why is it that a COM program using the Prog ID / Class ID doesn't locate the .NET DLL using the CodeBase? Second point of confusion: The GAC is specific to .NET. How is it involved in resolving COM references?

    Read the article

  • gcServer config not taking effect

    - by G33kKahuna
    I'm supporting a ASP.NET v2.0 app installed on a Windows 2003 SP3 Enterprise on a quad core 8G machine running on .NET 2.0 SP1. 1.before enabling the config, ran "tasklist /m mscorwks.dll" Image Name PID Modules w3wp.exe 7888 mscorwks.dll 2.add under section in web.config 3.ran IISRESET, rebooted server too 4.ran "tasklist /m mscorsvr.dll" INFO: No tasks are running which match the specified criteria. 5.ran "tasklist /m mscorwks.dll" Image Name PID Modules w3wp.exe 6251 mscorwks.dll It seems like gcServer is not taking effect. Are there any additional settings/ configurations necessary to get it working?

    Read the article

  • Saving Types generated via Reflection.Emit as code file (.cs) instead of saving it in .dll files

    - by Manish Sinha
    Before start let me tell my experience: I am experienced with C#.NET, web services, XML part and few more. Reflection is something new to me, though I have read extensively on it and tried out some experimental code, but haven't made anything great using reflection I checked out many examples of how we can create Type at runtime and then which can be saved in an assembly (.dll) files. Of all the examples I have seen is about saving the created types in the .dll files instead of code file. Isn't there any way to create the code file out of reflection? I need to create code file since I want to distribute code instead of compiled assemblies. What I want to do is something like xsd.exe does, either spit out a .dll or the code file(in any language). Isn't there any way to create a code file, since most of the place I can find is AssemblyBuilder ab = System.AppDomain.CurrentDomain.DefineDynamicAssembly(an, AssemblyBuilderAccess.Save); and then lastly ab.Save("QuoteOfTheDay.dll");

    Read the article

  • How do I create a dll project with Eclipse Ganymede?

    - by MRFerocius
    Guys; How are you doing today? I have to create a dll project on Eclipse Ganymede and I don´t know where to start... (I am a C# guy with VS). Can you please indicate me what type of project should I create to make a dll on Eclipse Ganymede so I can call the DLL from other Java Project? Thanks in advanced :D

    Read the article

  • C++ Compile problem when using Windows - CodeGear

    - by Carlos
    This is a follow-up question to this one i made earlier. Btw thanks Neil Butterworth for you help http://stackoverflow.com/questions/2461977/problem-compiling-c-in-codegear A quick recap. Im currently developing a C++ program for university, I used Netbeans 6.8 on my personal computer (Mac) and all works perfect. When I try them on my windows partition or at the university PC's using CodeGear RAD Studio 2009 & 2010 i was getting a few compile errors which were solved by adding the following header file: #include <string> However now the program does compile but it doesn't run, just a blank console. And am getting the following in the CodeGear event's log: Thread Start: Thread ID: 2024. Process Project1.exe (3280) Process Start: C:\Users\Carlos\Documents\RAD Studio\Projects\Debug\Project1.exe. Base Address: $00400000. Process Project1.exe (3280) Module Load: Project1.exe. Has Debug Info. Base Address: $00400000. Process Project1.exe (3280) Module Load: ntdll.dll. No Debug Info. Base Address: $77E80000. Process Project1.exe (3280) Module Load: KERNEL32.dll. No Debug Info. Base Address: $771C0000. Process Project1.exe (3280) Module Load: KERNELBASE.dll. No Debug Info. Base Address: $75FE0000. Process Project1.exe (3280) Module Load: cc32100.dll. No Debug Info. Base Address: $32A00000. Process Project1.exe (3280) Module Load: USER32.dll. No Debug Info. Base Address: $77980000. Process Project1.exe (3280) Module Load: GDI32.dll. No Debug Info. Base Address: $75F50000. Process Project1.exe (3280) Module Load: LPK.dll. No Debug Info. Base Address: $75AB0000. Process Project1.exe (3280) Module Load: USP10.dll. No Debug Info. Base Address: $76030000. Process Project1.exe (3280) Module Load: msvcrt.dll. No Debug Info. Base Address: $776A0000. Process Project1.exe (3280) Module Load: ADVAPI32.dll. No Debug Info. Base Address: $777D0000. Process Project1.exe (3280) Module Load: SECHOST.dll. No Debug Info. Base Address: $77960000. Process Project1.exe (3280) Module Load: RPCRT4.dll. No Debug Info. Base Address: $762F0000. Process Project1.exe (3280) Module Load: SspiCli.dll. No Debug Info. Base Address: $759F0000. Process Project1.exe (3280) Module Load: CRYPTBASE.dll. No Debug Info. Base Address: $759E0000. Process Project1.exe (3280) Module Load: IMM32.dll. No Debug Info. Base Address: $763F0000. Process Project1.exe (3280) Module Load: MSCTF.dll. No Debug Info. Base Address: $75AD0000. Process Project1.exe (3280) I would really appreciate any help or ideas on how to solve this problem. P.S: In the case anyone wonders why am I sticking with CodeGear is because is the IDE professors use to evaluate our assignments.

    Read the article

  • How can I tell [G]vim where to look for python26.dll?

    - by Ariel
    I have a version of Vim compiled with python 2.6 support enabled (from here). however vim cannot find the python26.dll. :version confirms +python/dyn :version and gvim.exe confirms DYNAMIC_PYTHON_DLL="python26.dll" echo PATH confirms python26.dll is in the search path. (both c:\windows\system32, and C:\python26) What could I be missing? Did I skip something silly?

    Read the article

  • Windows 7: L10N mechanics

    - by John Sonderson
    I have a localized version of Windows 7. I can't figure out where windows gets the names for files and directories on the system. For instance, consider the following (default) files. > cd C:\Users\Public\Pictures\Sample Pictures > dir Chrysanthemum.jpg Desert.jpg ... When I view these files on the default file explorer I see these names: Crisantemo.jpg Deserto.jpg ... This seems to imply that each file can be somehow assigned a localized name somewhere. However I cannot figure out how. Would appreciate if someone could shed some light on this issue. Thanks. UPDATE EDIT: The desktop.ini file in the folder containing Chrysanthemum.jpg contains the following entries. The .dll files used to translate the various resources are unfortunately not human-readable and I have no clue as to how they could be generated for other files created by the user to be translated, but they serve the purpose, and solve the mystery which lead to the post. Thanks. [LocalizedFileNames] Chrysanthemum.jpg=@%systemroot%\system32\SampleRes.dll,-101 Desert.jpg=@%systemroot%\system32\SampleRes.dll,-102 Hydrangeas.jpg=@%systemroot%\system32\SampleRes.dll,-103 Jellyfish.jpg=@%systemroot%\system32\SampleRes.dll,-104 Koala.jpg=@%systemroot%\system32\SampleRes.dll,-105 Tulips.jpg=@%systemroot%\system32\SampleRes.dll,-106 Lighthouse.jpg=@%systemroot%\system32\SampleRes.dll,-107 Penguins.jpg=@%systemroot%\system32\SampleRes.dll,-108 [.ShellClassInfo] LocalizedResourceName=@%SystemRoot%\system32\shell32.dll,-21805

    Read the article

  • Dll in both the bin and the gac, which one gets used?

    - by John Boker
    We have a web application that's deployed to many websites with only frontend changes, the shared backend portion has it's DLL in the GAC so we only have to update that one dll and all the sites get the update. Is there a way to override the GAC with a DLL in the /bin folder to test out new features before they get released?

    Read the article

  • Can I load a 32 bit DLL into a 64 bit process on Windows?

    - by Lee
    I recently upgraded a c# windows service to run as a 64 bit .net process. Normally, this would be trivial, but the system makes use of a 32-bit DLL written in C++. It is not an option to convert this DLL to 64 bit, so I wrapped the DLL in a separate 32 bit .net process and exposed a .net interface via remoting. This is quite a reliable solution, but I would prefer to run the system as a single process. Is there any way I can load my 32 bit DLL into a 64 bit process and access it directly (perhaps through some sort of thunking layer)?

    Read the article

  • BizTalk and SQL: Alternatives to the SQL receive adapter. Using Msmq to receive SQL data

    - by Leonid Ganeline
    If we have to get data from the SQL database, the standard way is to use a receive port with SQL adapter. SQL receive adapter is a solicit-response adapter. It periodically polls the SQL database with queries. That’s only way it can work. Sometimes it is undesirable. With new WCF-SQL adapter we can use the lightweight approach but still with the same principle, the WCF-SQL adapter periodically solicits the database with queries to check for the new records. Imagine the situation when the new records can appear in very broad time limits, some - in a second interval, others - in the several minutes interval. Our requirement is to process the new records ASAP. That means the polling interval should be near the shortest interval between the new records, a second interval. As a result the most of the poll queries would return nothing and would load the database without good reason. If the database is working under heavy payload, it is very undesirable. Do we have other choices? Sure. We can change the polling to the “eventing”. The good news is the SQL server could issue the event in case of new records with triggers. Got a new record –the trigger event is fired. No new records – no the trigger events – no excessive load to the database. The bad news is the SQL Server doesn’t have intrinsic methods to send the event data outside. For example, we would rather use the adapters that do listen for the data and do not solicit. There are several such adapters-listeners as File, Ftp, SOAP, WCF, and Msmq. But the SQL Server doesn’t have methods to create and save files, to consume the Web-services, to create and send messages in the queue, does it? Can we use the File, FTP, Msmq, WCF adapters to get data from SQL code? Yes, we can. The SQL Server 2005 and 2008 have the possibility to use .NET code inside SQL code. See the SQL Integration. How it works for the Msmq, for example: ·         New record is created, trigger is fired ·         Trigger calls the CLR stored procedure and passes the message parameters to it ·         The CLR stored procedure creates message and sends it to the outgoing queue in the SQL Server computer. ·         Msmq service transfers message to the queue in the BizTalk Server computer. ·         WCF-NetMsmq adapter receives the message from this queue. For the File adapter the idea is the same, the CLR stored procedure creates and stores the file with message, and then the File adapter picks up this file. Using WCF-NetMsmq adapter to get data from SQL I am describing the full set of the deployment and development steps for the case with the WCF-NetMsmq adapter. Development: 1.       Create the .NET code: project, class and method to create and send the message to the MSMQ queue. 2.       Create the SQL code in triggers to call the .NET code. Installation and Deployment: 1.       SQL Server: a.       Register the CLR assembly with .NET (CLR) code b.      Install the MSMQ Services 2.       BizTalk Server: a.       Install the MSMQ Services b.      Create the MSMQ queue c.       Create the WCF-NetMsmq receive port. The detailed description is below. Code .NET code … using System.Xml; using System.Xml.Linq; using System.Xml.Serialization;   //namespace MyCompany.MySolution.MyProject – doesn’t work. The assembly name is MyCompany.MySolution.MyProject // I gave up with the compound namespace. Seems the CLR Integration cannot work with it L. Maybe I’m wrong.     public class Event     {         static public XElement CreateMsg(int par1, int par2, int par3)         {             XNamespace ns = "http://schemas.microsoft.com/Sql/2008/05/TypedPolling/my_storedProc";             XElement xdoc =                 new XElement(ns + "TypedPolling",                     new XElement(ns + "TypedPollingResultSet0",                         new XElement(ns + "TypedPollingResultSet0",                             new XElement(ns + "par1", par1),                             new XElement(ns + "par2", par2),                             new XElement(ns + "par3", par3),                         )                     )                 );             return xdoc;         }     }   //////////////////////////////////////////////////////////////////////// … using System.ServiceModel; using System.ServiceModel.Channels; using System.Transactions; using System.Data; using System.Data.Sql; using System.Data.SqlTypes;   public class MsmqHelper {     [Microsoft.SqlServer.Server.SqlProcedure]     // msmqAddress as "net.msmq://localhost/private/myapp.myqueue";     public static void SendMsg(string msmqAddress, string action, int par1, int par2, int par3)     {         using (TransactionScope scope = new TransactionScope(TransactionScopeOption.Suppress))         {             NetMsmqBinding binding = new NetMsmqBinding(NetMsmqSecurityMode.None);             binding.ExactlyOnce = true;             EndpointAddress address = new EndpointAddress(msmqAddress);               using (ChannelFactory<IOutputChannel> factory = new ChannelFactory<IOutputChannel>(binding, address))             {                 IOutputChannel channel = factory.CreateChannel();                 try                 {                     XElement xe = Event.CreateMsg(par1, par2, par3);                     XmlReader xr = xe.CreateReader();                     Message msg = Message.CreateMessage(MessageVersion.Default, action, xr);                     channel.Send(msg);                     //SqlContext.Pipe.Send(…); // to test                 }                 catch (Exception ex)                 { …                 }             }             scope.Complete();         }     }   SQL code in triggers   -- sp_SendMsg was registered as a name of the MsmqHelper.SendMsg() EXEC sp_SendMsg'net.msmq://biztalk_server_name/private/myapp.myqueue', 'Create', @par1, @par2, @par3   Installation and Deployment On the SQL Server Registering the CLR assembly 1.       Prerequisites: .NET 3.5 SP1 Framework. It could be the issue for the production SQL Server! 2.       For more information, please, see the link http://nielsb.wordpress.com/sqlclrwcf/ 3.       Copy files: >copy “\Windows\Microsoft.net\Framework\v3.0\Windows Communication Foundation\Microsoft.Transactions.Bridge.dll” “\Program Files\Reference Assemblies\Microsoft\Framework\v3.0 \Microsoft.Transactions.Bridge.dll” If your machine is a 64-bit, run two commands: >copy “\Windows\Microsoft.net\Framework\v3.0\Windows Communication Foundation\Microsoft.Transactions.Bridge.dll” “\Program Files (x86)\Reference Assemblies\Microsoft\Framework\v3.0 \Microsoft.Transactions.Bridge.dll” >copy “\Windows\Microsoft.net\Framework64\v3.0\Windows Communication Foundation\Microsoft.Transactions.Bridge.dll” “\Program Files\Reference Assemblies\Microsoft\Framework\v3.0 \Microsoft.Transactions.Bridge.dll” 4.       Execute the SQL code to register the .NET assemblies: -- For x64 OS: CREATE ASSEMBLY SMdiagnostics AUTHORIZATION dbo FROM 'C:\Windows\Microsoft.NET\Framework\v3.0\Windows Communication Foundation\SMdiagnostics.dll' WITH permission_set = unsafe CREATE ASSEMBLY [System.Web] AUTHORIZATION dbo FROM 'C:\Windows\Microsoft.NET\Framework64\v2.0.50727\System.Web.dll' WITH permission_set = unsafe CREATE ASSEMBLY [System.Messaging] AUTHORIZATION dbo FROM 'C:\Windows\Microsoft.NET\Framework\v2.0.50727\System.Messaging.dll' WITH permission_set = unsafe CREATE ASSEMBLY [System.ServiceModel] AUTHORIZATION dbo FROM 'C:\Program Files (x86)\Reference Assemblies\Microsoft\Framework\v3.0\System.ServiceModel.dll' WITH permission_set = unsafe CREATE ASSEMBLY [System.Xml.Linq] AUTHORIZATION dbo FROM 'C:\Program Files\Reference Assemblies\Microsoft\Framework\v3.5\System.Xml.Linq.dll' WITH permission_set = unsafe   -- For x32 OS: --CREATE ASSEMBLY SMdiagnostics AUTHORIZATION dbo FROM 'C:\Windows\Microsoft.NET\Framework\v3.0\Windows Communication Foundation\SMdiagnostics.dll' WITH permission_set = unsafe --CREATE ASSEMBLY [System.Web] AUTHORIZATION dbo FROM 'C:\Windows\Microsoft.NET\Framework\v2.0.50727\System.Web.dll' WITH permission_set = unsafe --CREATE ASSEMBLY [System.Messaging] AUTHORIZATION dbo FROM 'C:\Windows\Microsoft.NET\Framework\v2.0.50727\System.Messaging.dll' WITH permission_set = unsafe --CREATE ASSEMBLY [System.ServiceModel] AUTHORIZATION dbo FROM 'C:\Program Files\Reference Assemblies\Microsoft\Framework\v3.0\System.ServiceModel.dll' WITH permission_set = unsafe 5.       Register the assembly with the external stored procedure: CREATE ASSEMBLY [HelperClass] AUTHORIZATION dbo FROM ’<FilePath>MyCompany.MySolution.MyProject.dll' WITH permission_set = unsafe where the <FilePath> - the path of the file on this machine! 6. Create the external stored procedure CREATE PROCEDURE sp_SendMsg (        @msmqAddress nvarchar(100),        @Action NVARCHAR(50),        @par1 int,        @par2 int,        @par3 int ) AS EXTERNAL NAME HelperClear.MsmqHelper.SendMsg   Installing the MSMQ Services 1.       Check if the MSMQ service is NOT installed. To check:  Start / Administrative Tools / Computer Management, on the left pane open the “Services and Applications”, search to the “Message Queuing”. If you cannot see it, follow next steps. 2.       Start / Control Panel / Programs and Features 3.       Click “Turn Windows Features on or off” 4.       Click Features, click “Add Features” 5.       Scroll down the feature list; open the “Message Queuing” / “Message Queuing Services”; and check the “Message Queuing Server” option  6.       Click Next; Click Install; wait to the successful finish of the installation Creating the MSMQ queue We don’t need to create the queue on the “sender” side. On the BizTalk Server Installing the MSMQ Services The same is as for the SQL Server. Creating the MSMQ queue 1.       Start / Administrative Tools / Computer Management, on the left pane open the “Services and Applications”, open the “Message Queuing”, and open the “Private Queues”. 2.       Right-click the “Private Queues”; choose New; choose “Private Queue”. 3.       Type the Queue name as ’myapp.myqueue'; check the “Transactional” option. Creating the WCF-NetMsmq receive port I will not go through this step in all details. It is straightforward. URI for this receive location should be 'net.msmq://localhost/private/myapp.myqueue'. Notes ·         The biggest problem is usually on the step the “Registering the CLR assembly”. It is hard to predict where are the assemblies from the assembly list, what version should be used, x86 or x64. It is pity of such “rude” integration of the SQL with .NET. ·         In couple cases the new WCF-NetMsmq port was not able to work with the queue. Try to replace the WCF- NetMsmq port with the WCF-Custom port with netMsmqBinding. It was working fine for me. ·         To test how messages go through the queue you can turn on the Journal /Enabled option for the queue. I used the QueueExplorer utility to look to the messages in Journal. The Computer Management can also show the messages but it shows only small part of the message body and in the weird format. The QueueExplorer can do the better job; it shows the whole body and Xml messages are in good color format.

    Read the article

  • Dependency Injection for Windows Phone 7

    - by Igor Zevaka
    I was trying to use Unity 2.0 beta 2 for Silverlight in my Windows Phone 7 project and I kept getting this crash: Microsoft.Practices.Unity.Silverlight.dll!Microsoft.Practices.ObjectBuilder2.DynamicMethodConstructorStrategy.DynamicMethodConstructorStrategy() + 0x1f bytes Microsoft.Practices.Unity.Silverlight.dll!Microsoft.Practices.ObjectBuilder2.DynamicMethodConstructorStrategy.DynamicMethodConstructorStrategy() + 0x1f bytes mscorlib.dll!System.Reflection.RuntimeConstructorInfo.InternalInvoke(System.Reflection.RuntimeConstructorInfo rtci = {System.Reflection.RuntimeConstructorInfo}, System.Reflection.BindingFlags invokeAttr = Default, System.Reflection.Binder binder = null, object parameters = {object[0]}, System.Globalization.CultureInfo culture = null, bool isBinderDefault = false, System.Reflection.Assembly caller = null, bool verifyAccess = true, ref System.Threading.StackCrawlMark stackMark = LookForMyCaller) mscorlib.dll!System.Reflection.RuntimeConstructorInfo.InternalInvoke(object obj = null, System.Reflection.BindingFlags invokeAttr = Default, System.Reflection.Binder binder = null, object[] parameters = {object[0]}, System.Globalization.CultureInfo culture = null, ref System.Threading.StackCrawlMark stackMark = LookForMyCaller) + 0x103 bytes mscorlib.dll!System.Activator.InternalCreateInstance(System.Type type = {Name = "DynamicMethodConstructorStrategy" FullName = "Microsoft.Practices.ObjectBuilder2.DynamicMethodConstructorStrategy"}, bool nonPublic = false, ref System.Threading.StackCrawlMark stackMark = LookForMyCaller) + 0xf0 bytes mscorlib.dll!System.Activator.CreateInstance() + 0xc bytes Microsoft.Practices.Unity.Silverlight.dll!Microsoft.Practices.ObjectBuilder2.StagedStrategyChain.AddNew(Microsoft.Practices.Unity.ObjectBuilder.UnityBuildStage stage = Creation) + 0x1d bytes Microsoft.Practices.Unity.Silverlight.dll!Microsoft.Practices.Unity.UnityDefaultStrategiesExtension.Initialize() + 0x6c bytes Microsoft.Practices.Unity.Silverlight.dll!Microsoft.Practices.Unity.UnityContainerExtension.InitializeExtension(Microsoft.Practices.Unity.ExtensionContext context = {Microsoft.Practices.Unity.UnityContainer.ExtensionContextImpl}) + 0x31 bytes Microsoft.Practices.Unity.Silverlight.dll!Microsoft.Practices.Unity.UnityContainer.AddExtension(Microsoft.Practices.Unity.UnityContainerExtension extension = {Microsoft.Practices.Unity.UnityDefaultStrategiesExtension}) + 0x1a bytes Microsoft.Practices.Unity.Silverlight.dll!Microsoft.Practices.Unity.UnityContainer.UnityContainer() + 0xf bytes Thinking I could resolve it I've tried a few things but to no avail. Turns out that this is a rather fundamental problem and my assumption that Windows Phone 7 is Silverlight 3 + Some other stuff is wrong. This page describes the differences between Mobile Silverlight and Silverlight 3. Of particular interest is this: The System.Reflection.Emit namespace is not supported in Silverlight for Windows Phone. This is precisely why Unity is crashing on the phone, DynamicMethodConstructorStrategy class uses System.Reflection.Emit quite extensively... So the question is, what alternative to Unity is there for Windows Phone 7?

    Read the article

  • App no longer working - any ideas

    - by hamishmcn
    I am out of ideas as to why my app has suddenly stopped working - perhaps the collective mind of the SO community can help... Background: I have a large application that has been working up until recently. Now when ever I try and run it I get the error "The application failed to initialize properly (0xc0000005)" This happens before the app gets to _tmain(). It happens in both release and debug builds. I have tried cleaning and rebuilding the projects and rebooted my PC. The call stack just shows entries for kernel32.dll and ntdll.dll The output window shows: First-chance exception at 0x00532c13 in a.exe: 0xC0000005: Access violation reading location 0xabababdb. First-chance exception at 0x7c964ed1 in a.exe: 0xC0000005: Access violation. Unhandled exception at 0x7c964ed1 in a.exe: 0xC0000005: Access violation. Any ideas? Edit: Okay - found the problem - it was dll related my app uses shared dlls a.dll and b.dll (and others) a.dll hardly every changes (and uses b.dll) b.dll was changed by another developer this morning and a.dll was not rebuilt. Depends.exe did not show any missing dlls, however a.dll no longer works because of the change to b.dll

    Read the article

  • Supress output from Visual Studio output pane (C++)

    - by Ryan Ginstrom
    When I run my Win32 project in the Visual Studio debugger, I get this huge screed of output about which DLLs were loaded, first-chance exceptions, and so on. Is there a way that I can suppress this output? Some day, I might want to know when 'C:\Windows\SysWOW64\ntdll.dll' was loaded, but normally I don't care. This is especially true when I'm running unit tests, and just want to be told whether any of the tests failed. This stuff isn't output with console applications, but it is with windows applications. To give an example of what I mean, here are the first lines from the output of a recent unit-test run. 'MyProject.exe': Loaded 'C:\dev\MyProject\Testing\MyProject.exe', Symbols loaded. 'MyProject.exe': Loaded 'C:\Windows\SysWOW64\ntdll.dll' 'MyProject.exe': Loaded 'C:\Windows\SysWOW64\kernel32.dll' 'MyProject.exe': Loaded 'C:\Windows\SysWOW64\KernelBase.dll' 'MyProject.exe': Loaded 'C:\Windows\SysWOW64\dbghelp.dll' 'MyProject.exe': Loaded 'C:\Windows\SysWOW64\msvcrt.dll' 'MyProject.exe': Loaded 'C:\Windows\SysWOW64\user32.dll' 'MyProject.exe': Loaded 'C:\Windows\SysWOW64\gdi32.dll' 'MyProject.exe': Loaded 'C:\Windows\SysWOW64\lpk.dll' 'MyProject.exe': Loaded 'C:\Windows\SysWOW64\usp10.dll' 'MyProject.exe': Loaded 'C:\Windows\SysWOW64\advapi32.dll' ... and on and on ...

    Read the article

  • Asus Machine fails to start due to missing msvcr.dll - what?

    - by Malcolm Anderson
    So first off a thanks to the internet, knoppix and a post over at http://www.overclock.net/windows/879553-msvcr80-dll-missing-catastrophic-failure.html   My Symptoms: my laptop would not boot.  Would not let me get anywhere.  Just like the symptoms in the post.   Thankfully, all I had to do was go rename my avg directory and all was good.  But I needed something to boot from and I knew and trusted Knoppix from my past linux experimental days.    If it wasn't for Knoppix, I would have probably reformatted my machine and I didn't want that.

    Read the article

  • How do I avoid the loader lock?

    - by Mark0978
    We have a managed app, that uses an assembly. That assembly uses some unmanaged C++ code. The Managed C++ code is in a dll, that depends on several other dlls. All of those Dlls are loaded by this code. (We load all the dll's that ImageCore.dll depends on first, so we can tell which ones are missing, otherwise it would just show up as ImageCore.dll failed to load, and the log file would give no clues as to why). class Interop { private const int DONT_RESOLVE_DLL_REFERENCES = 1; private static log4net.ILog log = log4net.LogManager.GetLogger("Imagecore.NET"); [DllImport("kernel32.dll", CharSet = CharSet.Auto, SetLastError = true)] private static extern IntPtr LoadLibraryEx(string fileName, IntPtr dummy, int flags); [DllImport("kernel32.dll", CharSet = CharSet.Auto, SetLastError = true)] private static extern IntPtr FreeLibrary(IntPtr hModule); static private String[] libs = { "log4cplus.dll", "yaz.dll", "zlib1.dll", "libxml2.dll" }; public static void PreloadAssemblies() { for (int i=0; i < libs.Length; ++i) { String libname = libs[i]; IntPtr hModule = LoadLibraryEx(libname, IntPtr.Zero, DONT_RESOLVE_DLL_REFERENCES); if(hModule == IntPtr.Zero) { log.Error("Unable to pre-load '" + libname + "'"); throw new DllNotFoundException("Unable to pre-load '" + libname + "'"); } else { FreeLibrary(hModule); } } IntPtr h = LoadLibraryEx("ImageCore.dll", IntPtr.Zero, 0); if (h == IntPtr.Zero) { throw new DllNotFoundException("Unable to pre-load ImageCore.dll"); } } } And this code is called by public class ImageDoc : IDisposable { static ImageDoc() { ImageHawk.ImageCore.Utility.Interop.PreloadAssemblies(); } ... } Which is static constructor. As near as I can understand it, as soon as we attempt to use an ImageDoc object, the dll that contains that assembly is loaded and as part of that load, the static constructor is called which in turn causes several other DLLs to be loaded as well. What I'm trying to figure out, is how do we defer loading of those DLLs so that we don't run smack dab into this loader lock that is being kicked out because of the static constructor. I've pieced this much together by looking at: http://social.msdn.microsoft.com/Forums/en-US/vsto/thread/dd192d7e-ce92-49ce-beef-3816c88e5a86 http://msdn.microsoft.com/en-us/library/aa290048%28VS.71%29.aspx http://forums.devx.com/showthread.php?t=53529 http://www.yoda.arachsys.com/csharp/beforefieldinit.html But I just can't seem to find a way to get these external DLLs to load without it happening at the point the class is loading. I think I need to get these LoadLibrary calls out of the static constructor, but don't know how to get them called before they are needed (except for how it is done here). I would prefer to not have to put this kind of knowledge of the dlls into every app that uses this assembly. (And I'm not sure that would even fix the problem.... The strange thing is that the exception only appears to be happening while running within the debugger, not while running outside the debugger.

    Read the article

< Previous Page | 45 46 47 48 49 50 51 52 53 54 55 56  | Next Page >