Search Results

Search found 71031 results on 2842 pages for 'windows search'.

Page 498/2842 | < Previous Page | 494 495 496 497 498 499 500 501 502 503 504 505  | Next Page >

  • How do you efficiently implement a document similarity search system?

    - by Björn Lindqvist
    How do you implement a "similar items" system for items described by a set of tags? In my database, I have three tables, Article, ArticleTag and Tag. Each Article is related to a number of Tags via a many-to-many relationship. For each Article i want to find the five most similar articles to implement a "if you like this article you will like these too" system. I am familiar with Cosine similarity and using that algorithm works very well. But it is way to slow. For each article, I need to iterate over all articles, calculate the cosine similarity for the article pair and then select the five articles with the highest similarity rating. With 200k articles and 30k tags, it takes me half a minute to calculate the similar articles for a single article. So I need another algorithm that produces roughly as good results as cosine similarity but that can be run in realtime and which does not require me to iterate over the whole document corpus each time. Maybe someone can suggest an off-the-shelf solution for this? Most of the search engines I looked at does not enable document similarity searching.

    Read the article

  • How to force user to user Administrator account in WinForms

    - by Smejda
    I have simple WinForms application where modifying Windows Registry. The problem is that in Vista / Windows 7 I need to force user to switch to administrator. I do not want to force user to Run as Administrator form start of the application. I want him to do it when there is necessity to write to registry. Best case scenario would be to reach exacly the same message which appear in lot's of Setups, when user need to 'switch' to Administrator so there is no necessity to Run as Administrator form beginning. How I can achieve this in .Net ?

    Read the article

  • How can Windows XP/7 users cleanly connect to Mac OS X Server 10.9.4 Mavericks with Active Directory integration?

    - by JakeGould
    I’m a Linux/Unix systems admin who also manages a Macintosh server infrastructure & there is a lone Mac Mini in the mix running 10.9.4 that I would like Windows XP & Windows 7 users to connect to with little or no hassle. The problem? Windows users can’t seem to even get to the point of a password prompt yet connect. Mind you this server replaced a Mac OS X 10.6.8 server that had issues, but never had issues with Windows users connected. The gist of this post is: The tons of different messages out there about Mac OS X 10.9.4 Samba support are mind-numbingly confusing. Can anyone share some solid specifics here? I’ve read pieces like this one here that suggest turning off file sharing & then adding a share with AFP/SMB enabled would work. But the suggestion seems to apply to 10.8. And from what I know a lot has changed in Samba support in 10.9 let alone the iterations to 10.9.4. Then I found this great tutorial here that explains things step-by-step. Which seems like it should work, but the problem is the example given applies to a local user created on the Mac when I would like users in an Active Directory group—which the Mac is bound to—access the Mac Mini shares. There are also tons of great tips here on MacWindows.com but nothing seems solid to the issue I am facing. So from what I am reading these are my options: Local User Versus Active Directory: Setup a common local user on the Mac OS X 10.9.4 server to be used for Samba sharing since Active Directory won’t work. Is this really the case? Because loss of AD integration is a major pain. Do Extended File Attributes Get Retained from Windows Users: If this were to work, how do extended attributes come into play? Loss of metadata & related info is not an option. How Fragile is Any of this to Updates: How does any of this shake out with Mac OS X updates as well as Windows updates? Installing Official, Open Source Samba: Would upgrading the Samba install on the server to the official open source Samba via a package like SMBUp or via the Hombrew method described here help or make the issue worse? I fully understand there have historically been issues in mixed environments, but nowadays Windows users connecting to a Mac seem to have a truly hellish road ahead of them. Unless I am missing something?

    Read the article

  • NAnt authorization access issue

    - by Luís Custódio
    I'm having a problem trying to move a file through my network, I want to transfer the release from my continuos integration virtual machine to the host of this VM. but i get this: System.UnauthorizedAccessException: Access to the path '\\192.168.0.36\E$\WebApps\MyProgram' is denied. at System.IO.__Error.WinIOError(Int32 errorCode, String maybeFullPath) at System.IO.Directory.InternalCreateDirectory(String fullPath, String path, DirectorySecurity dirSecurity) at System.IO.Directory.CreateDirectory(String path, DirectorySecurity directorySecurity) at NAnt.Core.Tasks.MoveTask.DoFileOperations() at NAnt.Core.Tasks.CopyTask.ExecuteTask() at NAnt.Core.Task.Execute() at NAnt.Core.Target.Execute() at NAnt.Core.Project.Execute(String targetName, Boolean forceDependencies) at NAnt.Core.Project.Execute() at NAnt.Core.Project.Run() I'm trying to transfer from a Windows Server 2003 R2 to a Windows Server 2008 R2.

    Read the article

  • Accessing py2exe program over network in Windows 98 throws ImportErrors

    - by darvids0n
    I'm running a py2exe-compiled python program from one server machine on a number of client machines (mapped to a network drive on every machine, say W:). For Windows XP and later machines, have so far had zero problems with Python picking up W:\python23.dll (yes, I'm using Python 2.3.5 for W98 compatibility and all that). It will then use W:\zlib.pyd to decompress W:\library.zip containing all the .pyc files like os and such, which are then imported and the program runs no problems. The issue I'm getting is on some Windows 98 SE machines (note: SOME Windows 98 SE machines, others seem to work with no apparent issues). What happens is, the program runs from W:, the W:\python23.dll is, I assume, found (since I'm getting Python ImportErrors, we'd need to be able to execute a Python import statement), but a couple of things don't work: 1) If W:\library.zip contains the only copy of the .pyc files, I get ZipImportError: can't decompress data; zlib not available (nonsense, considering W:\zlib.pyd IS available and works fine with the XP and higher machines on the same network). 2) If the .pyc files are actually bundled INSIDE the python exe by py2exe, OR put in the same directory as the .exe, OR put into a named subdirectory which is then set as part of the PYTHONPATH variable (e.g W:\pylib), I get ImportError: no module named os (os is the first module imported, before sys and anything else). Come to think of it, sys.path wouldn't be available to search if os was imported before it maybe? I'll try switching the order of those imports but my question still stands: Why is this a sporadic issue, working on some networks but not on others? And how would I force Python to find the files that are bundled inside the very executable I run? I have immediate access to the working Windows 98 SE machine, but I only get access to the non-working one (a customer of mine) every morning before their store opens. Thanks in advance! EDIT: Okay, big step forward. After debugging with PY2EXE_VERBOSE, the problem occurring on the specific W98SE machine is that it's not using the right path syntax when looking for imports. Firstly, it doesn't seem to read the PYTHONPATH environment variable (there may be a py2exe-specific one I'm not aware of, like PY2EXE_VERBOSE). Secondly, it only looks in one place before giving up (if the files are bundled inside the EXE, it looks there. If not, it looks in library.zip). EDIT 2: In fact, according to this, there is a difference between the sys.path in the Python interpreter and that of Py2exe executables. Specifically, sys.path contains only a single entry: the full pathname of the shared code archive. Blah. No fallbacks? Not even the current working directory? I'd try adding W:\ to PATH, but py2exe doesn't conform to any sort of standards for locating system libraries, so it won't work. Now for the interesting bit. The path it tries to load atexit, os, etc. from is: W:\\library.zip\<module>.<ext> Note the single slash after library.zip, but the double slash after the drive letter (someone correct me if this is intended and should work). It looks like if this is a string literal, then since the slash isn't doubled, it's read as an (invalid) escape sequence and the raw character is printed (giving W:\library.zipos.pyd, W:\library.zipos.dll, ... instead of with a slash); if it is NOT a string literal, the double slash might not be normpath'd automatically (as it should be) and so the double slash confuses the module loader. Like I said, I can't just set PYTHONPATH=W:\\library.zip\\ because it ignores that variable. It may be worth using sys.path.append at the start of my program but hard-coding module paths is an absolute LAST resort, especially since the problem occurs in ONE configuration of an outdated OS. Any ideas? I have one, which is to normpath the sys.path.. pity I need os for that. Another is to just append os.getenv('PATH') or os.getenv('PYTHONPATH') to sys.path... again, needing the os module. The site module also fails to initialise, so I can't use a .pth file. I also recently tried the following code at the start of the program: for pth in sys.path: fErr.write(pth) fErr.write(' to ') pth.replace('\\\\','\\') # Fix Windows 98 pathing issues fErr.write(pth) fErr.write('\n') But it can't load linecache.pyc, or anything else for that matter; it can't actually execute those commands from the looks of things. Is there any way to use built-in functionality which doesn't need linecache to modify the sys.path dynamically? Or am I reduced to hard-coding the correct sys.path?

    Read the article

  • this operation has been canceled due to restrictions in effect on this computer

    - by Dan
    I have this HUGELY irritating problem on Windows 7 (x64). Whenever I click on ANY link (that exists on a Word document, excel or Outlook), I get an alert box with the message: "This operation has been canceled due to restrictions in effect on this computer" I have been scouring my settings and the internet for a solution, but to no avail. Has anybody else encounted this problem? It even happens when I click anchors in word documents i.e. I can't even click on an entry in a Table of Contents to go to the appropriate page - I get this same error then. Is this a Windows 7 thing? Anyway to turn this off?

    Read the article

  • How can I enable Vista/Win 7 theming/style for a ToolTip control?

    - by Joakim Hårsman
    In Windows Vista and Windows 7, ToolTips have a new visual style or theme, they are shiny grey metallic. How can I enable the new style for a ToolTip control? Some controls, like ListViews and ToolBars, use the new tooltips automatically, but other tooltips are rendered with the old yellow XP style. I've tried sending an TTM_SETWINDOWTHEME message but nothing happens and I'm not sure what string I am supposed to use for the visual style name. SetWindowTheme doesn't work either, I've used it successfully on ListViews and TreeViews to set the "Explorer" style (see http://www.danielmoth.com/Blog/TreeViewVista.aspx), but that doesn't seem to work on ToolTips. I'm using the plain win32 C API.

    Read the article

  • I copied a Windows VM from Mac VMWare to Windows VMWare Player. It runs, but very slowly...

    - by thrillscience
    I copied a Windows XP VM that I've been using on my Mac (VMWare Fusion)to a Windows 7 machine that has VMWare 7 installed. I was quite pleased when it started up and appeared to work, but when I actually tried to use it, I noticed it runs very slowly. Unusably so. It takes about 10 minutes, for example, for a Visual Studio 2010 project to open (with VS 2010 running in the VM). Is this supposed to work? Is there any way to fix this VM to get it to run well under Windows VMWare Player?

    Read the article

  • WPF integrate Windows live authentication for windows health vault

    - by AnD
    Hi all, I'm just wondering if there's any way for WPF application integrated with windows live ID? and it's actually for windows health vault [www.healthvault.com] so health vault is using windows live id or open id to login into their system. and what i gonna do is, creating wpf application (instead of web application) for health vault, so all of the login form username pass and everything is handled inside the wpf application without showing/using any internet browser. so since this's quite new for me, i hope if there's somebody ever did this before especially for health vault system that run on standalone wpf app. alright, so that's it, thank you in advance!

    Read the article

  • Set window to stays always on desktop on windows7

    - by Nuno
    Hi, I'm trying to set my window a child of the desktop, and i'm doing this like this: HWND ProgmanHwnd = ::FindWindowEx( ::FindWindowEx( ::FindWindow(L"Progman", L"Program Manager"), NULL, L"SHELLDLL_DefView", L""), NULL, L"SysListView32", L"FolderView"); SetParent(m_hWnd, ProgmanHwnd); This works fine in windowsXP, my window is underneath all windows and when i press the "show desktop" option the window shows and all other "normal" windows are hide. But in Win7 when i do the above code the same window is not displayed, in spy++ i can see that my window is a child window of the SysListView32 but it not display (and it has the WM_VISIBLE style)? What i'm missing? or what changed from winXP to win7? how can i do this to work on win7? Update: It's got something to do with aero theme, because if i change the desktop theme to the basic then the window is displayed, but if i switch back to one of the aero theme then is hided again. Thanks

    Read the article

  • Spaces and Parenthesis in windows PATH variable screws up batch files.

    - by NoName
    So, my path variable (System-Adv Settings-Env Vars-System-PATH) is set to: C:\Python26\Lib\site-packages\PyQt4\bin; %SystemRoot%\system32; %SystemRoot%; %SystemRoot%\System32\Wbem; %SYSTEMROOT%\System32\WindowsPowerShell\v1.0\; C:\Python26\; C:\Python26\Scripts\; C:\cygwin\bin; "C:\PathWithSpaces\What_is_this_bullshit"; "C:\PathWithSpaces 1.5\What_is_this_bullshit_1.5"; "C:\PathWithSpaces (2.0)\What_is_this_bullshit_2.0"; "C:\Program Files (x86)\IronPython 2.6"; "C:\Program Files (x86)\Subversion\bin"; "C:\Program Files (x86)\Git\cmd"; "C:\Program Files (x86)\PuTTY"; "C:\Program Files (x86)\Mercurial"; Z:\droid\android-sdk-windows\tools; Although, obviously, without the newlines. Notice the lines containing PathWithSpaces - the first has no spaces, the second has a space, and the third has a space followed by a parenthesis. Now, notice the output of this batch file: C:\Program Files (x86)\Microsoft Visual Studio 9.0\VC\bin\>vcvars32.bat C:\Program Files (x86)\Microsoft Visual Studio 9.0\VC\bin>"C:\Program Files (x86 )\Microsoft Visual Studio 9.0\Common7\Tools\vsvars32.bat" Setting environment for using Microsoft Visual Studio 2008 x86 tools. \What_is_this_bullshit_2.0";"C:\Program was unexpected at this time. C:\Program Files (x86)\Microsoft Visual Studio 9.0\VC\bin> set "PATH=C:\Pro gram Files\Microsoft SDKs\Windows\v6.0A\bin;C:\Python26\Lib\site-packages\PyQt4\ bin;C:\Windows\system32;C:\Windows;C:\Windows\System32\Wbem;C:\Windows\System32\ WindowsPowerShell\v1.0\;C:\Python26\;C:\Python26\Scripts\;C:\cygwin\bin;"C:\Path WithSpaces\What_is_this_bullshit";"C:\PathWithSpaces 1.5\What_is_this_bullshit_1 .5";"C:\PathWithSpaces (2.0)\What_is_this_bullshit_2.0";"C:\Program Files (x86)\ IronPython 2.6";"C:\Program Files (x86)\Subversion\bin";"C:\Program Files (x86)\ Git\cmd";"C:\Program Files (x86)\PuTTY";"C:\Program Files (x86)\Mercurial";Z:\dr oid\android-sdk-windows\tools;" or specifically the line: \What_is_this_bullshit_2.0";"C:\Program was unexpected at this time. So, what is this bullshit? Specifically: Directory in path that is properly escaped with quotes, but with no spaces = fine Directory in path that is properly escaped with quotes, and has spaces but no parenthesis = fine Directory in path that is properly escaped with quotes, and has spaces and has a parenthesis = ERROR Whats going on here? How can I fix this? I'll probably resort to a junction point to let my tools still work as workaround, but if you have any insight into this, please let me know :)

    Read the article

  • Search and replace hundreds of strings in tens of thousands of files?

    - by C Johnson
    I am looking into changing the file name of hundreds of files in a (C/C++) project that I work on. The problem is our software has tens of thousands of files that including (i.e. #include) these hundreds of files that will get changed. This looks like a maintenance nightmare. If I do this I will be stuck in Ultra-Edit for weeks, rolling hundreds of regex's by hand like so: ^\#include.*["<\\/]stupid_name.*$ with #include <dir/new_name.h> Such drudgery would be worse than peeling hundreds of potatoes in a sunken submarine in the antarctic with a spoon. I think it would rather be ideal to put the inputs and outputs into a table like so: stupid_name.h <-> <dir/new_name.h> stupid_nameb.h <-> <dir/new_nameb.h> stupid_namec.h <-> <dir/new_namec.h> and feed this into a regular expression engine / tool / app / etc... My Ultimate Question: Is there a tool that will do that? Bonus Question: Is it multi-threaded? I looked at quite a few search and replace topics here on this website, and found lots of standard queries that asked a variant of the following question: standard question: Replace one term in N files. as opposed to: my question: Replace N terms in N files. Thanks in advance for any replies.

    Read the article

  • C#: standard Windows menu bars in Windows Forms

    - by BoltClock
    I noticed that adding a MenuStrip (from the VS Toolbox) to my form design doesn't yield a menu bar like many native Windows applications. Instead I get a menu bar like VS's own. None of the style settings for MenuStrip appear to mimic the much more common native menu bar. Is there a way to add a menu bar to my Windows Forms application that looks the same as the one you see in Notepad, Task Manager, Windows Explorer and others? (Preferably with the designer, but I wouldn't mind adding it programmatically either.)

    Read the article

  • Possible to rank partial matches in Postgres full text search?

    - by Joe
    I'm trying to calculate a ts_rank for a full-text match where some of the terms in the query may not be in the ts_vector against which it is being matched. I would like the rank to be higher in a match where more words match. Seems pretty simple? Because not all of the terms have to match, I have to | the operands, to give a query such as to_tsquery('one|two|three') (if it was &, all would have to match). The problem is, the rank value seems to be the same no matter how many words match. In other words, it's maxing rather than multiplying the clauses. select ts_rank('one two three'::tsvector, to_tsquery('one')); gives 0.0607927. select ts_rank('one two three'::tsvector, to_tsquery('one|two|three|four')); gives the expected lower value of 0.0455945 because 'four' is not the vector. But select ts_rank('one two three'::tsvector, to_tsquery('one|two')); gives 0.0607927 and likewise select ts_rank('one two three'::tsvector, to_tsquery('one|two|three')); gives 0.0607927 I would like the result of ts_rank to be higher if more terms match. Possible? To counter one possible response: I cannot calculate all possible subsequences of the search query as intersections and then union them all in a query because I am going to be working with large queries. I'm sure there are plenty of arguments against this anyway! Edit: I'm aware of ts_rank_cd but it does not solve the above problem.

    Read the article

  • Why is this attempt at a binary search crashing?

    - by Ian Campbell
    I am fairly new to the concept of a binary search, and am trying to write a program that does this in Java for personal practice. I understand the concept of this well, but my code is not working. There is a run-time exception happening in my code that just caused Eclipse, and then my computer, to crash... there are no compile-time errors here though. Here is what I have so far: public class BinarySearch { // instance variables int[] arr; int iterations; // constructor public BinarySearch(int[] arr) { this.arr = arr; iterations = 0; } // instance method public int findTarget(int targ, int[] sorted) { int firstIndex = 1; int lastIndex = sorted.length; int middleIndex = (firstIndex + lastIndex) / 2; int result = sorted[middleIndex - 1]; while(result != targ) { if(result > targ) { firstIndex = middleIndex + 1; middleIndex = (firstIndex + lastIndex) / 2; result = sorted[middleIndex - 1]; iterations++; } else { lastIndex = middleIndex + 1; middleIndex = (firstIndex + lastIndex) / 2; result = sorted[middleIndex - 1]; iterations++; } } return result; } // main method public static void main(String[] args) { int[] sortedArr = new int[] { 1, 3, 5, 7, 9, 11, 13, 15, 17, 19, 21, 23, 25, 27, 29 }; BinarySearch obj = new BinarySearch(sortedArr); int target = sortedArr[8]; int result = obj.findTarget(target, sortedArr); System.out.println("The original target was -- " + target + ".\n" + "The result found was -- " + result + ".\n" + "This took " + obj.iterations + " iterations to find."); } // end of main method } // end of class BinarySearch

    Read the article

  • How can I have a VBA macro perform a Search/Replace in formulas across an entire workbook?

    - by richardtallent
    I distribute an Excel workbook to a number of users, and they are supposed to have a particular macro file pre-installed in their XLSTART folder. If they don't have the macro installed correctly, and they send the workbook back to me, any formulas depending on it include the full path of the macro, e.g.: 'C:\Documents and Settings\richard.tallent\Application Data\ Microsoft\Excel\XLSTART\pcs.xls'!MyMacroFunction() I want to create a quick macro I can use to remove the improper path from every formula in the workbook. I've successfully retrieved the special folder using GetSpecialFolder (an external function that is working just fine), but the Replace call itself shown below throws an "Application-defined or object-defined error". Public Sub FixBrokenMacroFormulas() Dim badpath As String badpath = "'" & GetSpecialFolder(AppDataFolder) & "\Microsoft\Excel\XLSTART\mymacro.xls'!" Dim Sheet As Worksheet For Each Sheet In ActiveWorkbook.Sheets Call Sheet.Activate Call Sheet.Select(True) Call Selection.Replace(What:=badpath, Replacement:="", LookIn:=xlFormulas) ''//LookAt:=xlPart, MatchCase:=False, SearchFormat:=False, ReplaceFormat:=False Next End Sub Automating search and replace isn't exactly my forte, what am I doing wrong? I've already commented out some of the parameters that don't seem essential.

    Read the article

  • Is it possible to change an "Unidentified Network" into a "Home" or "Work" network on Windows 7

    - by Rhys
    I have a problem with Windows 7 RC (7100). I frequently use a crossover network cable on WinXP with static IP addresses to connect to various industrial devices (e.g. robots, pumps, valves or even other Windows PCs) that have Ethernet network ports. When I do this on Windows 7, the network connection is classed as an "Unidentified Network" in Networks and Sharing Center and the public firewall profile is enforced by Windows. I do not want to change the public profile and would prefer to use the Home or Work profile instead. For other networks like Home and Work I'm able to click on them and change the classification. This is not available for unidentified networks. My questions are these:- Is there a way to manual override the "Unidentified Network" classification? What tests are performed on the network that fail, therefore classifying it as an "Unidentified Network" By googling (hitting mainly vista issues) it seems that you need to ensure that the default gateway is not 0.0.0.0. I've done this. I've also tried to remove IPv6 but this does not seem possible on Windows 7. UPDATE For those still having problems here is the answer to my issue and the possible reasons why:- Win7 keeps a list of the networks you visit by (I am assuming, but don’t know for sure) the MACID of the device pointed to by the Default Gateway. The default gateway is usually the constant device in a network (i.e. the NAT or router) so can be used to uniquely identify one network from another. The default gateway in the IPv4 properties panel must therefore point to an actual endpoint so windows can then keep track of it. If there is a device at the end of the Default Gateway windows will identify it and track it remembering its settings. The ways you can therefore fool Win7 is to either point the default gateway to your own IP address, or the IP address of the target device you’re communicating with. This will have the side effect of expecting that target device to start routing packets for IP destinations that are outside your subnet. So some applications on Win7 will try to communicate with the internet, these will be passed on to the default gateway (either back you the same IP address or a target device that is not a router) and thus will eventually timeout because neither can route packets. Which you can usually live with. This gets slightly complicated when you mix a this type of connection with a real connection to the internet via WIFI. The wired network card usually has priority when routing because of the “interface metric” so some applications might not connect correctly.

    Read the article

  • Changing The Underlying Background Color Of A Swing Window

    - by dimo414
    As discussed here, when resizing a Swing application in Vista (and Windows 7, which is what I'm using) you get a black background in the right/bottom corner while Swing's repaint catches up to the changes. Playing with other applications (Windows Explorer (Native), Firefox (C++?), and Eclipse (Java)) I notice that they all have this same problem - contrary to what the folks in the link above say - but they minimize the problem by having a grey fill color, which is far less visually jarring than the black that appears in Swing. I'm wondering if there's some way to change this so that Swing behaves like these other applications? I tried setting the background color of the JFrame, but to no avail.

    Read the article

  • Is there a way to allow a property of a user control to be modified only during design time?

    - by Dan
    I've looked into the DesignOnly attribute, but that doesn't seem to accomplish what I want*. Basically, I'm looking for some way to indicate that some property of a user control (let's say Text) can be modified during design time -- i.e., from the Windows Forms designer in VS (or presumably from any GUI designer that can be used to modify a Windows Forms GUI) -- but not during run time. Once the application is running, the property should effectively be readonly. Is this possible? * When I add the DesignOnly attribute to a property, the value I select for that property from design mode doesn't seem to stick; the property just ends up being whatever I have it set to by default in code.

    Read the article

  • Restoring using SyncBack without profiles

    - by Thomas Matthews
    I backed up my internal hard drive (C:) using SyncBack onto an external (USB) hard drive with maximum compression. I then performed a clean install of Windows Vista onto the computer. I forgot to copy the SyncBack logs before the clean install. And now when ever I try to restore a directory, the RAR/ZIP files are copied to the system hard drive instead of extracting their contents to the hard drive. Also, SyncBack is not traversing the folders during the Restore process. How can I tell SyncBack to expand the compressed files? I am running the freeware version of SyncBack. I have to create new log files (unless SyncBack put them somewhere on the external drive). My alternative is to write a program that traverses the folders on the external drive and extracts files from the RAR/ZIP files. I am using Windows Vista, Service Pack 2, and the data size prior to backup was about 200 GB. (The backup process took over 72 hours due to "hiccups").

    Read the article

  • Can someone who understands C code help me understand this code?

    - by Benjamin
    INT GetTree (HWND hWnd, HTREEITEM hItem, HKEY *pRoot, TCHAR *pszKey, INT nMax) { TV_ITEM tvi; TCHAR szName[256]; HTREEITEM hParent; HWND hwndTV = GetDlgItem (hWnd, ID_TREEV); memset (&tvi, 0, sizeof (tvi)); hParent = TreeView_GetParent (hwndTV, hItem); if (hParent) { // Get the parent of the parent of the... GetTree (hWnd, hParent, pRoot, pszKey, nMax); // Get the name of the item. tvi.mask = TVIF_TEXT; tvi.hItem = hItem; tvi.pszText = szName; tvi.cchTextMax = dim(szName); TreeView_GetItem (hwndTV, &tvi); //send the TVM_GETITEM message? lstrcat (pszKey, TEXT ("\\")); lstrcat (pszKey, szName); } else { *pszKey = TEXT ('\0'); szName[0] = TEXT ('\0'); // Get the name of the item. tvi.mask = TVIF_TEXT | TVIF_PARAM; tvi.hItem = hItem; tvi.pszText = szName; tvi.cchTextMax = dim(szName); if (TreeView_GetItem (hwndTV, &tvi)) //*pRoot = (HTREEITEM)tvi.lParam; //original hItem = (HTREEITEM)tvi.lParam; else { INT rc = GetLastError(); } } return 0; } The block of code that begins with the comment "Get the name of the item" does not make sense to me. If you are getting the listview item why does the code set the parameters of the item being retrieved, because if you already had the values there would be no need to retrieve them. Secondly near the comment "original" is the original line of code which will compile with a varning under embedded visual c++, but if you copy the exact same code into visual studio 2008 it will not compile. Since I did not write any of this code and am trying to learn is it possible the original author made a mistake on this line, since the *pRoot should point to and HKEY type yet he is casting to an HTREEITEM type which should never work since the data types don't match? (Side note someone with a better reputation should add a windows ce tag to SO since windows mobile is not the same as windows ce.)

    Read the article

  • __doPostBack is undefined on DotNetNuke website for IE 10

    - by nick
    I have a DotNetNuke site, and today a customer called in and said it wasn't working on IE 10. Specifically the login and register links weren't working, but they do in compatibility mode. I took a look on our test windows 8 machine and saw that it was failing because __doPostBack was undefined. I've been searching for a fix for the last 6ish hours, and what I've been able to find is that apparently the IE10 user agent is covered in the ie.browser file and that I should install this hotfix and reboot the server. That didn't work. I haven't noticed any changes, even though I think the new ie.browser file should match the new user agent. What other steps can I take to fix the problem? Note: the server is running .NET 3.5 with service pack 1 on Windows server 2003. The site is running DotNetNuke 05.06.02. Any suggestions would be greatly appreciated.

    Read the article

  • Where is the windows app installed + .NET + VS2005

    - by The King
    I deployed a windows application in the following website http://StagingServer/MyProgs/MPP/ on my intranet site, using the Publish Wizard of VS 2005... I accepted all defaults (including Offline support). My users were also able to install the same from the path specified. But when I try to find out the exact location of the EXE in the client, it is not pointing anywhere. I also tried a file search but in vain. Initially I thought the application is running from the server itself, but we were able to start the app, even when the server is down (ofcourse it takes more time to search for updates initially). Ps : The app is showing even in control panel... Raja

    Read the article

  • Does F# documentation have a way to search for functions by their types?

    - by Nathan Sanders
    Say I want to know if F# has a library function of type ('T -> bool) -> 'T list -> int ie, something that counts how many items of a list that a function returns true for. (or returns the index of the first item that returns true) I used to use the big list at the MSR site for F# before the documentation on MSDN was ready. I could just search the page for the above text because the types were listed. But now the MSDN documentation only lists types on the individual pages--the module page is a mush of descriptive text. Google kinda-sorta works, but it can't help with // compatible interfaces ('T -> bool) -> Seq<'T> -> int // argument-swaps Seq<'T> -> ('T -> bool) -> int // type-variable names ('a -> bool) -> Seq<'a> -> int // wrappers ('a -> bool) -> 'a list -> option<int> // uncurried versions ('T -> bool) * 'T list -> int // .NET generic syntax ('T -> bool) -> List<'T> -> int // methods List<'T> member : ('T -> bool) -> int Haskell has a standalone program for this called Hoogle. Does F# have an equivalent, like Fing or something?

    Read the article

  • Works for Short Input, Fails for Long Input. How to Solve?

    - by r0ach
    I've this program which finds substring in a string. It works for small inputs. But fails for long inputs. Here's the program: //Find Substring in given String #include <stdio.h> #include <string.h> main() { //Variable Initialization int i=0,j=0,k=0; char sentence[50],temp[50],search[50]; //Gets Strings printf("Enter Sentence: "); fgets(sentence,50,stdin); printf("Enter Search: "); fgets(search,50,stdin); //Actual Work Loop while(sentence[i]!='\0') { k=i;j=0; while(sentence[k]==search[j]) { temp[j]=sentence[k]; j++; k++; } if(strcmp(temp,search)==0) break; i++; } //Output Printing printf("Found string at: %d \n",k-strlen(search)); } Works for: Enter Sentence: good evening Enter Search: evening Found string at 6 Fails for: Enter Sentence: dear god please make this work Enter Search: make Found string at 25 Which is totally wrong. Can any expert find me a solution? P.S: This is kinda like reinventing the wheel since strstr() has this functionality. But I'm trying for a non-library way of doing it.

    Read the article

< Previous Page | 494 495 496 497 498 499 500 501 502 503 504 505  | Next Page >