Search Results

Search found 23897 results on 956 pages for 'installation configuration'.

Page 499/956 | < Previous Page | 495 496 497 498 499 500 501 502 503 504 505 506  | Next Page >

  • Applicability of the Joel Test to web development companies

    - by dreftymac
    QUESTION: How can you re-write the questions of the Joel test to apply to web developers? 1. Do you use source control? (source control for all aspects of your app, including configuration, database and user-based settings?) 2. Can you make a build in one step? (can you deploy a site from staging to prod in 1 step?) ... 10. Do you have testers? (how do you test AJAX and CSS?) BACKGROUND: This is for people who work in a shop that does some web development but also uses some off-the-shelf tools like Drupal and Wordpress, but doing custom development on top of that. RELATED LINKS: http://www.joelonsoftware.com/articles/fog0000000043.html What do you think about the Joel Test?

    Read the article

  • Can't get wireless on macbook pro 8,2

    - by Jeff
    I'm a linux Newb, and I have tried several of the fixes listed to try and get my wifi drivers to work, but to no avail. Does anyone here know why this isn't working for me, or better yet, how to fix it? Under lspci -vvv I get the following output: 03:00.0 Network controller: Broadcom Corporation BCM4331 802.11a/b/g/n (rev 02) Subsystem: Apple Inc. AirPort Extreme Control: I/O- Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx- Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast TAbort- SERR- Kernel modules: bcma With sudo lshw -class network I get this output: *-network UNCLAIMED description: Network controller product: BCM4331 802.11a/b/g/n vendor: Broadcom Corporation physical id: 0 bus info: pci@0000:03:00.0 version: 02 width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list configuration: latency=0 resources: memory:b0600000-b0603fff Any help would be greatly appreciated!

    Read the article

  • Issues with ganglia and upstart in 13.04

    - by theist
    I'm having an issue with ganglia-monitor and upstart. Just after installing it starts and it cannot be stopped. I tried to solve it following http://upstart.ubuntu.com/cookbook/#expect but I can achieve upstart to track the actual pid of gmond. Assuming the configuration of the init config is wrong i followed direcetions in http://upstart.ubuntu.com/cookbook/#how-to-establish-fork-count in order to try to fix it. As it states a count of 1 means "exec fork" stanza and 2 means "exec daemon" .... gmond gives a count of 8... And of course I can get it to track the actual PID. I haven't found a bug report or something like that. Is there something I missed ? Upstart seems to be failing and the worst thing is that upstart hangs on start/stop and I cannot even uninstall or reconfigure packages.

    Read the article

  • Why does my domain not show up in Google anymore?

    - by Earlz
    So I have had a website since about 2006. It's http://earlz.biz.tm . Recently I've noticed that no results will show up for it in google. I do have a secondary domain(that I plan on getting rid of) pointing to it but I don't understand why google would suddenly not show my site. I believe it was showing up a few months ago and my website is hardly ever down, like one or two days I believe has been the most it's been down in a row in this time period. Is there something wrong with my DNS or other configuration that would make google not index me? For reference I've tried: earlz.biz.tm site:earlz.biz.tm and the heading from my site "Earlz.biz.tm -- The reasoning is bacon" A few show up with the therusticstone.com domain(the one I plan to point somewhere else) but none show up directly linking to earlz.biz.tm.

    Read the article

  • MVVM Light V4 preview 2 (BL0015) #mvvmlight

    - by Laurent Bugnion
    Over the past few weeks, I have worked hard on a few new features for MVVM Light V4. Here is a second early preview (consider this pre-alpha if you wish). The features are unit-tested, but I am now looking for feedback and there might be bugs! Bug correction: Messenger.CleanupList is now thread safe This was an annoying bug that is now corrected: In some circumstances, an exception could be thrown when the Messenger’s recipients list was cleaned up (i.e. the “dead” instances were removed). The method is called now and then and the exception was thrown apparently at random. In fact it was really a multi-threading issue, which is now corrected. Bug correction: AllowPartiallyTrustedCallers prevents EventToCommand to work This is a particularly annoying regression bug that was introduced in BL0014. In order to allow MVVM Light to work in XBAPs too, I added the AllowPartiallyTrustedCallers attribute to the assemblies. However, we just found out that this causes issues when using EventToCommand. In order to allow EventToCommand to continue working, I reverted to the previous state by removing the AllowPartiallyTrustedCallers attribute for now. I will work with my friends at Microsoft to try and find a solution. Stay tuned. Bug correction: XML documentation file is now generated in Release configuration The XML documentation file was not generated for the Release configuration. This was a simple flag in the project file that I had forgotten to set. This is corrected now. Applying EventToCommand to non-FrameworkElements This feature has been requested in order to be able to execute a command when a Storyboard is completed. I implemented this, but unfortunately found out that EventToCommand can only be added to Storyboards in Silverlight 3 and Silverlight 4, but not in WPF or in Windows Phone 7. This obviously limits the usefulness of this change, but I decided to publish it anyway, because it is pretty damn useful in Silverlight… Why not in WPF? In WPF, Storyboards added to a resource dictionary are frozen. This is a feature of WPF which allows to optimize certain objects for performance: By freezing them, it is a contract where we say “this object will not be modified anymore, so do your perf optimization on them without worrying too much”. Unfortunately, adding a Trigger (such as EventTrigger) to an object in resources does not work if this object is frozen… and unfortunately, there is no way to tell WPF not to freeze the Storyboard in the resources… so there is no way around that (at least none I can see. In Silverlight, objects are not frozen, so an EventTrigger can be added without problems. Why not in WP7? In Windows Phone 7, there is a totally different issue: Adding a Trigger can only be done to a FrameworkElement, which Storyboard is not. Here I think that we might see a change in a future version of the framework, so maybe this small trick will work in the future. Workaround? Since you cannot use the EventToCommand on a Storyboard in WPF and in WP7, the workaround is pretty obvious: Handle the Completed event in the code behind, and call the Command from there on the ViewModel. This object can be obtained by casting the DataContext to the ViewModel type. This means that the View needs to know about the ViewModel, but I never had issues with that anyway. New class: NotifyPropertyChanged Sometimes when you implement a model object (for example Customer), you would like to have it implement INotifyPropertyChanged, but without having all the frills of a ViewModelBase. A new class named NotifyPropertyChanged allows you to do that. This class is a simple implementation of INotifyPropertyChaned (with all the overloads of RaisePropertyChanged that were implemented in BL0014). In fact, ViewModelBase inherits NotifyPropertyChanged. ViewModelBase does not implement IDisposable anymore The IDisposable interface and the Dispose method had been marked obsolete in the ViewModelBase class already in V3. Now they have been removed. Note: By this, I do not mean that IDisposable is a bad interface, or that it shouldn’t be used on viewmodels. In the contrary, I know that this interface is very useful in certain circumstances. However, I think that having it by default on every instance of ViewModelBase was sending a wrong message. This interface has a strong meaning in .NET: After Dispose has been executed, the instance should not be used anymore, and should be ready for garbage collection. What I really wanted to have on ViewModelBase was rather a simple cleanup method, something that can be executed now and then during runtime. This is fulfilled by the ICleanup interface and its Cleanup method. If your ViewModels need IDisposable, you can still use it! You will just have to implement the interface on the class itself, because it is not available on ViewModelBase anymore. What’s next? I have a couple exciting new features implemented already but that need more testing before they go live… Just stay tuned and by MIX11 (12-14 April 2011), we should see at least a major addition to MVVM Light Toolkit, as well as another smaller feature which is pretty cool nonetheless More about this later! Happy Coding Laurent   Laurent Bugnion (GalaSoft) Subscribe | Twitter | Facebook | Flickr | LinkedIn

    Read the article

  • Microsoft Press Deal of the Day - 9/Jul/2012 - Windows® Communication Foundation 4 Step by Step

    - by TATWORTH
    Today's Deal of the Day from Microsoft Press at http://shop.oreilly.com/product/0790145302403.do?code=MSDEAL is Windows® Communication Foundation 4 Step by Step"Teach yourself the essentials of Windows Communication Foundation (WCF) 4 -- one step at a time. With this practical, learn-by-doing tutorial, you get the clear guidance and hands-on examples you need to begin creating Web services for robust Windows-based business applications. Discover how to: Build and host SOAP and REST servicesMaintain service contracts and data contractsControl configuration and communications programmaticallyImplement message encryption, authentication, and authorizationManage identity with Windows CardSpaceBegin working with Windows Workflow Foundation to create scalable and durable business servicesImplement service discovery and message routingOptimize performance with service throttling, encoding, and streamingIntegrate WCF services with ASP.NET clients and enterprise services components"  Note the comment:Use code: MSDEAL

    Read the article

  • Oracle VM Administration: Oracle VM Server for x86 - new Training

    - by Antoinette O'Sullivan
     Oracle VM Administration: Oracle VM Server for x86 - new course just released. This 3 day hands-on course teaches students how to build a virtualization platform using the Oracle VM Manager and Oracle VM Server for x86. Students learn how deploy and manage highly configurable, inter-connected virtual machines. The course teaches students how to install and configure Oracle VM Server for x86 as well as details of network and storage configuration, pool and repository creation, and virtual machine management. You can follow this class that brings you great hands-on experience either in-class or from your own desk.

    Read the article

  • Oracle VM Administration: Oracle VM Server for x86 - new Training

    - by Antoinette O'Sullivan
     Oracle VM Administration: Oracle VM Server for x86 - new course just released. This 3 day hands-on course teaches students how to build a virtualization platform using the Oracle VM Manager and Oracle VM Server for x86. Students learn how deploy and manage highly configurable, inter-connected virtual machines. The course teaches students how to install and configure Oracle VM Server for x86 as well as details of network and storage configuration, pool and repository creation, and virtual machine management. You can follow this class that brings you great hands-on experience either in-class or from your own desk.

    Read the article

  • JMS Step 5 - How to Create an 11g BPEL Process Which Reads a Message Based on an XML Schema from a JMS Queue

    - by John-Brown.Evans
    JMS Step 5 - How to Create an 11g BPEL Process Which Reads a Message Based on an XML Schema from a JMS Queue .jblist{list-style-type:disc;margin:0;padding:0;padding-left:0pt;margin-left:36pt} ol{margin:0;padding:0} .c12_5{vertical-align:top;width:468pt;border-style:solid;background-color:#f3f3f3;border-color:#000000;border-width:1pt;padding:5pt 5pt 5pt 5pt} .c8_5{vertical-align:top;border-style:solid;border-color:#000000;border-width:1pt;padding:5pt 5pt 0pt 5pt} .c10_5{vertical-align:top;width:207pt;border-style:solid;border-color:#000000;border-width:1pt;padding:5pt 5pt 5pt 5pt} .c14_5{vertical-align:top;border-style:solid;border-color:#000000;border-width:1pt;padding:0pt 5pt 0pt 5pt} .c21_5{background-color:#ffffff} .c18_5{color:#1155cc;text-decoration:underline} .c16_5{color:#666666;font-size:12pt} .c5_5{background-color:#f3f3f3;font-weight:bold} .c19_5{color:inherit;text-decoration:inherit} .c3_5{height:11pt;text-align:center} .c11_5{font-weight:bold} .c20_5{background-color:#00ff00} .c6_5{font-style:italic} .c4_5{height:11pt} .c17_5{background-color:#ffff00} .c0_5{direction:ltr} .c7_5{font-family:"Courier New"} .c2_5{border-collapse:collapse} .c1_5{line-height:1.0} .c13_5{background-color:#f3f3f3} .c15_5{height:0pt} .c9_5{text-align:center} .title{padding-top:24pt;line-height:1.15;text-align:left;color:#000000;font-size:36pt;font-family:"Arial";font-weight:bold;padding-bottom:6pt} .subtitle{padding-top:18pt;line-height:1.15;text-align:left;color:#666666;font-style:italic;font-size:24pt;font-family:"Georgia";padding-bottom:4pt} li{color:#000000;font-size:10pt;font-family:"Arial"} p{color:#000000;font-size:10pt;margin:0;font-family:"Arial"} h1{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:24pt;font-family:"Arial";font-weight:normal} h2{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:18pt;font-family:"Arial";font-weight:normal} h3{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:14pt;font-family:"Arial";font-weight:normal} h4{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:12pt;font-family:"Arial";font-weight:normal} h5{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:11pt;font-family:"Arial";font-weight:normal} h6{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:10pt;font-family:"Arial";font-weight:normal} Welcome to another post in the series of blogs which demonstrates how to use JMS queues in a SOA context. The previous posts were: JMS Step 1 - How to Create a Simple JMS Queue in Weblogic Server 11g JMS Step 2 - Using the QueueSend.java Sample Program to Send a Message to a JMS Queue JMS Step 3 - Using the QueueReceive.java Sample Program to Read a Message from a JMS Queue JMS Step 4 - How to Create an 11g BPEL Process Which Writes a Message Based on an XML Schema to a JMS Queue Today we will create a BPEL process which will read (dequeue) the message from the JMS queue, which we enqueued in the last example. The JMS adapter will dequeue the full XML payload from the queue. 1. Recap and Prerequisites In the previous examples, we created a JMS Queue, a Connection Factory and a Connection Pool in the WebLogic Server Console. Then we designed and deployed a BPEL composite, which took a simple XML payload and enqueued it to the JMS queue. In this example, we will read that same message from the queue, using a JMS adapter and a BPEL process. As many of the configuration steps required to read from that queue were done in the previous samples, this one will concentrate on the new steps. A summary of the required objects is listed below. To find out how to create them please see the previous samples. They also include instructions on how to verify the objects are set up correctly. WebLogic Server Objects Object Name Type JNDI Name TestConnectionFactory Connection Factory jms/TestConnectionFactory TestJMSQueue JMS Queue jms/TestJMSQueue eis/wls/TestQueue Connection Pool eis/wls/TestQueue Schema XSD File The following XSD file is used for the message format. It was created in the previous example and will be copied to the new process. stringPayload.xsd <?xml version="1.0" encoding="windows-1252" ?> <xsd:schema xmlns:xsd="http://www.w3.org/2001/XMLSchema"                 xmlns="http://www.example.org"                 targetNamespace="http://www.example.org"                 elementFormDefault="qualified">   <xsd:element name="exampleElement" type="xsd:string">   </xsd:element> </xsd:schema> JMS Message After executing the previous samples, the following XML message should be in the JMS queue located at jms/TestJMSQueue: <?xml version="1.0" encoding="UTF-8" ?><exampleElement xmlns="http://www.example.org">Test Message</exampleElement> JDeveloper Connection You will need a valid Application Server Connection in JDeveloper pointing to the SOA server which the process will be deployed to. 2. Create a BPEL Composite with a JMS Adapter Partner Link In the previous example, we created a composite in JDeveloper called JmsAdapterWriteSchema. In this one, we will create a new composite called JmsAdapterReadSchema. There are probably many ways of incorporating a JMS adapter into a SOA composite for incoming messages. One way is design the process in such a way that the adapter polls for new messages and when it dequeues one, initiates a SOA or BPEL instance. This is possibly the most common use case. Other use cases include mid-flow adapters, which are activated from within the BPEL process. In this example we will use a polling adapter, because it is the most simple to set up and demonstrate. But it has one disadvantage as a demonstrative model. When a polling adapter is active, it will dequeue all messages as soon as they reach the queue. This makes it difficult to monitor messages we are writing to the queue, because they will disappear from the queue as soon as they have been enqueued. To work around this, we will shut down the composite after deploying it and restart it as required. (Another solution for this would be to pause the consumption for the queue and resume consumption again if needed. This can be done in the WLS console JMS-Modules -> queue -> Control -> Consumption -> Pause/Resume.) We will model the composite as a one-way incoming process. Usually, a BPEL process will do something useful with the message after receiving it, such as passing it to a database or file adapter, a human workflow or external web service. But we only want to demonstrate how to dequeue a JMS message using BPEL and a JMS adapter, so we won’t complicate the design with further activities. However, we do want to be able to verify that we have read the message correctly, so the BPEL process will include a small piece of embedded java code, which will print the message to standard output, so we can view it in the SOA server’s log file. Alternatively, you can view the instance in the Enterprise Manager and verify the message. The following steps are all executed in JDeveloper. Create the project in the same JDeveloper application used for the previous examples or create a new one. Create a SOA Project Create a new project and choose SOA Tier > SOA Project as its type. Name it JmsAdapterReadSchema. When prompted for the composite type, choose Empty Composite. Create a JMS Adapter Partner Link In the composite editor, drag a JMS adapter over from the Component Palette to the left-hand swim lane, under Exposed Services. This will start the JMS Adapter Configuration Wizard. Use the following entries: Service Name: JmsAdapterRead Oracle Enterprise Messaging Service (OEMS): Oracle WebLogic JMS AppServer Connection: Use an application server connection pointing to the WebLogic server on which the JMS queue and connection factory mentioned under Prerequisites above are located. Adapter Interface > Interface: Define from operation and schema (specified later) Operation Type: Consume Message Operation Name: Consume_message Consume Operation Parameters Destination Name: Press the Browse button, select Destination Type: Queues, then press Search. Wait for the list to populate, then select the entry for TestJMSQueue , which is the queue created in a previous example. JNDI Name: The JNDI name to use for the JMS connection. As in the previous example, this is probably the most common source of error. This is the JNDI name of the JMS adapter’s connection pool created in the WebLogic Server and which points to the connection factory. JDeveloper does not verify the value entered here. If you enter a wrong value, the JMS adapter won’t find the queue and you will get an error message at runtime, which is very difficult to trace. In our example, this is the value eis/wls/TestQueue . (See the earlier step on how to create a JMS Adapter Connection Pool in WebLogic Server for details.) Messages/Message SchemaURL: We will use the XSD file created during the previous example, in the JmsAdapterWriteSchema project to define the format for the incoming message payload and, at the same time, demonstrate how to import an existing XSD file into a JDeveloper project. Press the magnifying glass icon to search for schema files. In the Type Chooser, press the Import Schema File button. Select the magnifying glass next to URL to search for schema files. Navigate to the location of the JmsAdapterWriteSchema project > xsd and select the stringPayload.xsd file. Check the “Copy to Project” checkbox, press OK and confirm the following Localize Files popup. Now that the XSD file has been copied to the local project, it can be selected from the project’s schema files. Expand Project Schema Files > stringPayload.xsd and select exampleElement: string . Press Next and Finish, which will complete the JMS Adapter configuration.Save the project. Create a BPEL Component Drag a BPEL Process from the Component Palette (Service Components) to the Components section of the composite designer. Name it JmsAdapterReadSchema and select Template: Define Service Later and press OK. Wire the JMS Adapter to the BPEL Component Now wire the JMS adapter to the BPEL process, by dragging the arrow from the adapter to the BPEL process. A Transaction Properties popup will be displayed. Set the delivery mode to async.persist. This completes the steps at the composite level. 3 . Complete the BPEL Process Design Invoke the BPEL Flow via the JMS Adapter Open the BPEL component by double-clicking it in the design view of the composite.xml, or open it from the project navigator by selecting the JmsAdapterReadSchema.bpel file. This will display the BPEL process in the design view. You should see the JmsAdapterRead partner link in the left-hand swim lane. Drag a Receive activity onto the BPEL flow diagram, then drag a wire (left-hand yellow arrow) from it to the JMS adapter. This will open the Receive activity editor. Auto-generate the variable by pressing the green “+” button and check the “Create Instance” checkbox. This will result in a BPEL instance being created when a new JMS message is received. At this point it would actually be OK to compile and deploy the composite and it would pick up any messages from the JMS queue. In fact, you can do that to test it, if you like. But it is very rudimentary and would not be doing anything useful with the message. Also, you could only verify the actual message payload by looking at the instance’s flow in the Enterprise Manager. There are various other possibilities; we could pass the message to another web service, write it to a file using a file adapter or to a database via a database adapter etc. But these will all introduce unnecessary complications to our sample. So, to keep it simple, we will add a small piece of Java code to the BPEL process which will write the payload to standard output. This will be written to the server’s log file, which will be easy to monitor. Add a Java Embedding Activity First get the full name of the process’s input variable, as this will be needed for the Java code. Go to the Structure pane and expand Variables > Process > Variables. Then expand the input variable, for example, "Receive1_Consume_Message_InputVariable > body > ns2:exampleElement”, and note variable’s name and path, if they are different from this one. Drag a Java Embedding activity from the Component Palette (Oracle Extensions) to the BPEL flow, after the Receive activity, then open it to edit. Delete the example code and replace it with the following, replacing the variable parts with those in your sample, if necessary.: System.out.println("JmsAdapterReadSchema process picked up a message"); oracle.xml.parser.v2.XMLElement inputPayload =    (oracle.xml.parser.v2.XMLElement)getVariableData(                           "Receive1_Consume_Message_InputVariable",                           "body",                           "/ns2:exampleElement");   String inputString = inputPayload.getFirstChild().getNodeValue(); System.out.println("Input String is " + inputPayload.getFirstChild().getNodeValue()); Tip. If you are not sure of the exact syntax of the input variable, create an Assign activity in the BPEL process and copy the variable to another, temporary one. Then check the syntax created by the BPEL designer. This completes the BPEL process design in JDeveloper. Save, compile and deploy the process to the SOA server. 3. Test the Composite Shut Down the JmsAdapterReadSchema Composite After deploying the JmsAdapterReadSchema composite to the SOA server it is automatically activated. If there are already any messages in the queue, the adapter will begin polling them. To ease the testing process, we will deactivate the process first Log in to the Enterprise Manager (Fusion Middleware Control) and navigate to SOA > soa-infra (soa_server1) > default (or wherever you deployed your composite to) and click on JmsAdapterReadSchema [1.0] . Press the Shut Down button to disable the composite and confirm the following popup. Monitor Messages in the JMS Queue In a separate browser window, log in to the WebLogic Server Console and navigate to Services > Messaging > JMS Modules > TestJMSModule > TestJMSQueue > Monitoring. This is the location of the JMS queue we created in an earlier sample (see the prerequisites section of this sample). Check whether there are any messages already in the queue. If so, you can dequeue them using the QueueReceive Java program created in an earlier sample. This will ensure that the queue is empty and doesn’t contain any messages in the wrong format, which would cause the JmsAdapterReadSchema to fail. Send a Test Message In the Enterprise Manager, navigate to the JmsAdapterWriteSchema created earlier, press Test and send a test message, for example “Message from JmsAdapterWriteSchema”. Confirm that the message was written correctly to the queue by verifying it via the queue monitor in the WLS Console. Monitor the SOA Server’s Output A program deployed on the SOA server will write its standard output to the terminal window in which the server was started, unless this has been redirected to somewhere else, for example to a file. If it has not been redirected, go to the terminal session in which the server was started, otherwise open and monitor the file to which it was redirected. Re-Enable the JmsAdapterReadSchema Composite In the Enterprise Manager, navigate to the JmsAdapterReadSchema composite again and press Start Up to re-enable it. This should cause the JMS adapter to dequeue the test message and the following output should be written to the server’s standard output: JmsAdapterReadSchema process picked up a message. Input String is Message from JmsAdapterWriteSchema Note that you can also monitor the payload received by the process, by navigating to the the JmsAdapterReadSchema’s Instances tab in the Enterprise Manager. Then select the latest instance and view the flow of the BPEL component. The Receive activity will contain and display the dequeued message too. 4 . Troubleshooting This sample demonstrates how to dequeue an XML JMS message using a BPEL process and no additional functionality. For example, it doesn’t contain any error handling. Therefore, any errors in the payload will result in exceptions being written to the log file or standard output. If you get any errors related to the payload, such as Message handle error ... ORABPEL-09500 ... XPath expression failed to execute. An error occurs while processing the XPath expression; the expression is /ns2:exampleElement. ... etc. check that the variable used in the Java embedding part of the process was entered correctly. Possibly follow the tip mentioned in previous section. If this doesn’t help, you can delete the Java embedding part and simply verify the message via the flow diagram in the Enterprise Manager. Or use a different method, such as writing it to a file via a file adapter. This concludes this example. In the next post, we will begin with an AQ JMS example, which uses JMS to write to an Advanced Queue stored in the database. Best regards John-Brown Evans Oracle Technology Proactive Support Delivery

    Read the article

  • ASP.NET 4 Website Fails to Start on Your TFS 2010 Server?

    - by jdanforth
    Getting a “Could not find permission set named ‘ASP.Net’” error on your TFS 2010 server? It may have to do with the fact you’re trying to run ASP.NET as a child site of a SharePoint Web Site. The problem is described in the “ASP.NET 4 braking changes” site:   This error occurs because the ASP.NET 4 code access security (CAS) infrastructure looks for a permission set named ASP.Net. However, the partial trust configuration file that is referenced by WSS_Minimal does not contain any permission sets with that name. Currently there is not a version of SharePoint available that is compatible with ASP.NET. As a result, you should not attempt to run an ASP.NET 4 Web site as a child site underneath SharePoint Web sites.   There is a workaround you could try by setting this in your web.config, if you know what you’re doing: <trust level="Full" originUrl="" />

    Read the article

  • using Unity Android In a sub view and add actionbar and style

    - by aeroxr1
    I exported a simple animation from Unity3D (version 4.5) in android project. With eclipse I modified the manifest and added another activity. In this activity I put a button that it makes start the animation,and this is the result. The action bar appear in the main activity but it doesn't in the unity's activity :( How can I add the action bar and the style of the first activity to unity's animation activity ? This is the unity's activity's code : package com.rabidgremlin.tut.redcube; import android.app.NativeActivity; import android.content.res.Configuration; import android.graphics.PixelFormat; import android.os.Bundle; import android.view.KeyEvent; import android.view.MotionEvent; import android.view.View; import android.view.ViewGroup; import android.view.Window; import android.view.WindowManager; import com.unity3d.player.UnityPlayer; public class UnityPlayerNativeActivity extends NativeActivity { protected UnityPlayer mUnityPlayer; // don't change the name of this variable; referenced from native code // Setup activity layout @Override protected void onCreate (Bundle savedInstanceState) { //requestWindowFeature(Window.FEATURE_NO_TITLE); super.onCreate(savedInstanceState); getWindow().takeSurface(null); //setTheme(android.R.style.Theme_NoTitleBar_Fullscreen); getWindow().setFormat(PixelFormat.RGB_565); mUnityPlayer = new UnityPlayer(this); /*if (mUnityPlayer.getSettings ().getBoolean ("hide_status_bar", true)) getWindow ().setFlags (WindowManager.LayoutParams.FLAG_FULLSCREEN, WindowManager.LayoutParams.FLAG_FULLSCREEN); */ setContentView(mUnityPlayer); mUnityPlayer.requestFocus(); } // Quit Unity @Override protected void onDestroy () { mUnityPlayer.quit(); super.onDestroy(); } // Pause Unity @Override protected void onPause() { super.onPause(); mUnityPlayer.pause(); } // eliminiamo questa onResume() e proviamo a modificare la onResume() // Resume Unity @Override protected void onResume() { super.onResume(); mUnityPlayer.resume(); } // inseriamo qualche modifica qui // This ensures the layout will be correct. @Override public void onConfigurationChanged(Configuration newConfig) { super.onConfigurationChanged(newConfig); mUnityPlayer.configurationChanged(newConfig); } // Notify Unity of the focus change. @Override public void onWindowFocusChanged(boolean hasFocus) { super.onWindowFocusChanged(hasFocus); mUnityPlayer.windowFocusChanged(hasFocus); } // For some reason the multiple keyevent type is not supported by the ndk. // Force event injection by overriding dispatchKeyEvent(). @Override public boolean dispatchKeyEvent(KeyEvent event) { if (event.getAction() == KeyEvent.ACTION_MULTIPLE) return mUnityPlayer.injectEvent(event); return super.dispatchKeyEvent(event); } // Pass any events not handled by (unfocused) views straight to UnityPlayer @Override public boolean onKeyUp(int keyCode, KeyEvent event) { return mUnityPlayer.injectEvent(event); } @Override public boolean onKeyDown(int keyCode, KeyEvent event) { return mUnityPlayer.injectEvent(event); } @Override public boolean onTouchEvent(MotionEvent event) { return mUnityPlayer.injectEvent(event); } /*API12*/ public boolean onGenericMotionEvent(MotionEvent event) { return mUnityPlayer.injectEvent(event); } } And this is the AndroidManifest.xml android:versionCode="1" android:versionName="1.0" > <!-- android:theme="@android:style/Theme.NoTitleBar"--> <supports-screens android:anyDensity="true" android:largeScreens="true" android:normalScreens="true" android:smallScreens="true" android:xlargeScreens="true" /> <application android:icon="@drawable/app_icon" android:label="@string/app_name" android:theme="@android:style/Theme.Holo.Light" > <activity android:name="com.rabidgremlin.tut.redcube.UnityPlayerNativeActivity" android:configChanges="mcc|mnc|locale|touchscreen|keyboard|keyboardHidden|navigation|orientation|screenLayout|uiMode|screenSize|smallestScreenSize|fontScale" android:label="@string/app_name" android:screenOrientation="portrait" > <!--android:launchMode="singleTask"--> <meta-data android:name="unityplayer.UnityActivity" android:value="true" /> <meta-data android:name="unityplayer.ForwardNativeEventsToDalvik" android:value="false" /> </activity> <activity android:name="com.rabidgremlin.tut.redcube.MainActivity" android:label="@string/title_activity_main" > <intent-filter> <action android:name="android.intent.action.MAIN" /> <category android:name="android.intent.category.LAUNCHER" /> </intent-filter> </activity> </application> <uses-sdk android:minSdkVersion="17" android:targetSdkVersion="19" /> <uses-feature android:glEsVersion="0x00020000" /> </manifest>

    Read the article

  • Mobile redirect strategy

    - by Kevin
    Looking for help on deciding how to redirect users to a mobile optimized version of my site (m.mysite.com). Looking at two methods: Server configuration (.htaccess or even varnish) Webapp (php) The problem I see with #1 is with the "view full site" link on the mobile site. If a user clicks that link and they go to mysite.com won't the server just redirect them back to m.mysite.com? For #2 I could create a cookie that is checked in addition to the user agent. Any suggestions/comments? Is there a better way to "remember" if the user clicked "visit full site"? Thanks, Kevin

    Read the article

  • Creating a Reverse Proxy with URL Rewrite for IIS

    - by OWScott
    There are times when you need to reverse proxy through a server. The most common example is when you have an internal web server that isn’t exposed to the internet, and you have a public web server accessible to the internet. If you want to serve up traffic from the internal web server, you can do this through the public web server by creating a tunnel (aka reverse proxy). Essentially, you can front the internal web server with a friendly URL, even hiding custom ports. For example, consider an internal web server with a URL of http://10.10.0.50:8111. You can make that available through a public URL like http://tools.mysite.com/ as seen in the following image. The URL can be made public or it can be used for your internal staff and have it password protected and/or locked down by IP address. This is easy to do with URL Rewrite and IIS. You will also need Application Request Routing (ARR) installed even though for a simple reverse proxy you won’t use most of ARR’s functionality. If you don’t already have URL Rewrite and ARR installed you can do so easily with the Web Platform Installer. A lot can be said about reverse proxies and many different situations and ways to route the traffic and handle different URL patterns. However, my goal here is to get you up and going in the easiest way possible. Then you can dig in deeper after you get the base configuration in place. URL Rewrite makes a reverse proxy very easy to set up. Note that the URL Rewrite Add Rules template doesn’t include Reverse Proxy at the server level. That’s not to say that you can’t create a server-level reverse proxy, but the URL Rewrite rules template doesn’t help you with that. Getting Started First you must create a website on your public web server that has the public bindings that you need. Alternately, you can use an existing site and route using conditions for certain traffic. After you’ve created your site then open up URL Rewrite at the site level. Using the “Add Rule(s)…” template that is opened from the right-hand actions pane, create a new Reverse Proxy rule. If you receive a prompt (the first time) that the proxy functionality needs to be enabled, select OK. This is telling you that a proxy can route traffic outside of your web server, which happens to be our goal in this case. Be aware that reverse proxy rules can be dangerous if you open sites from inside you network to the world, so just be aware of what you’re doing and why. The next and final step of the template asks a few questions. The first textbox asks the name of the internal web server. In our example, it’s 10.10.0.50:8111. This can be any URL, including a subfolder like internal.mysite.com/blog. Don’t include the http or https here. The template assumes that it’s not entered. You can choose whether to perform SSL Offloading or not. If you leave this checked then all requests to the internal server will be over HTTP regardless of the original web request. This can help with performance and SSL bindings if all requests are within a trusted network. If the network path between the two web servers is not completely trusted and safe then uncheck this. Next, the template enables you to create an outbound rule. This is used to rewrite links in the page to look like your public domain name rather than the internal domain name. Outbound rules have a lot of CPU overhead because the entire web content needs to be parsed and updated. However, if you need it, then it’s well worth the extra CPU hit on the web server. If you check the “Rewrite the domain names of the links in HTTP responses” checkbox then the From textbox will be filled in with what you entered for the inbound rule. You can enter your friendly public URL for the outbound rule. This will essentially replace any reference to 10.10.0.50:8111 (or whatever you enter) with tools.mysite.com in all <a>, <form>, and <img> tags on your site. That’s it! Well, there is a lot more that you can do, this but will give you the base configuration. You can now visit www.mysite.com on your public web server and it will serve up the site from your internal web server. You should see two rules show up; one inbound and one outbound. You can edit these, add conditions, and tweak them further as needed. One common issue that can occur without outbound rules has to do with compression. If you run into errors with the new proxied site, try turning off compression to confirm if that’s the issue. Here’s a link with details on how to deal with compression and outbound rules. I hope this was helpful to get started and to see how easy it is to create a simple reverse proxy using URL Rewrite for IIS.

    Read the article

  • Solarized Theme in Terminal Vim on Xubuntu

    - by Dave Long
    I recently setup my laptop with Xubuntu 13.04 and after installing and setting up all my dotfiles, which have previously worked fine with Ubuntu 13.04 with XFCE installed, my colorscheme in Vim is using the wrong colors. I dropped the terminalrc file from the Solarized repository in ~/.config/xfce4/terminal/terminalrc and setup my dotfiles (which can be found at http://github.com/davejlong/dotfiles). Here is a screen shot of my Temrinal when I open a file in Vim: Here is the contents of ~/.config/xfce4/terminal/terminalrc: [Configuration] ColorCursor=#0f0f49499999 ColorForeground=#838394949696 ColorBackground=#00002b2b3636 ColorPalette1=#070736364242 ColorPalette2=#dcdc32322f2f ColorPalette3=#858599990000 ColorPalette4=#b5b589890000 ColorPalette5=#26268b8bd2d2 ColorPalette6=#d3d336368282 ColorPalette7=#2a2aa1a19898 ColorPalette8=#eeeee8e8d5d5 ColorPalette9=#00002b2b3636 ColorPalette10=#cbcb4b4b1616 ColorPalette11=#58586e6e7575 ColorPalette12=#65657b7b8383 ColorPalette13=#838394949696 ColorPalette14=#6c6c7171c4c4 ColorPalette15=#9393a1a1a1a1 ColorPalette16=#fdfdf6f6e3e3 Term=xterm-256color FontName=Inconsolata Medium 12 MiscAlwaysShowTabs=FALSE MiscBell=FALSE MiscBordersDefault=TRUE MiscCursorBlinks=FALSE MiscCursorShape=TERMINAL_CURSOR_SHAPE_BLOCK MiscDefaultGeometry=80x24 MiscInheritGeometry=FALSE MiscMenubarDefault=TRUE MiscMouseAutohide=FALSE MiscToolbarDefault=FALSE MiscConfirmClose=TRUE MiscCycleTabs=TRUE MiscTabCloseButtons=TRUE MiscTabCloseMiddleClick=TRUE MiscTabPosition=GTK_POS_TOP MiscHighlightUrls=TRUE MiscScrollAlternateScreen=TRUE

    Read the article

  • Mathematica 8 crashes Ubuntu 13.10

    - by Georgy Ivanov
    I have Mathematica 8 installed on my Ubuntu laptop since 2011. I updated Ubuntu several times, and experienced no problems with Mathematica. It also worked smoothly after I updated Ubuntu to 13.10 (it worked for sure for a week after update). When I tried to start Mathematica today by executing a .sh-file, the screen went black, I was logged out from the session and thrown back to the login screen. Typing mathematica in the terminal produced the same effect. Typing mathematica -cleanstart or mathematica -mesa did not help. Starting Gnome session with or without effects did not help Launching mathematica under another user account did not help. I still can run text-only version of mathematica by typing math in the terminal. I don't remember making any changes to my configuration except for installing updates. Is there any quick way to fix this behavior? How can I know which component exactly crashed? Where should I look for crash logs?

    Read the article

  • Ikoula lance sa machine virtuelle à 1 Euro, l'hébergeur veut concurrencer Amazon et son offre EC2

    Ikoula lance sa machine virtuelle à 1€ L'hébergeur veut concurrencer Amazon et son offre EC2 Ikoula lance une offre Cloud qu'il qualifie de « unique sur le marché ». Destinée à concurrencer Amazon, et son offre EC2, l'hébergeur informatique a décidé de proposer une VM (machine virtuelle) à 1 €. Le principe est simple. Une franchise de 1€ donne accès à une machine d'une configuration standard. Le supplément est facturé à l'usage. « La VM à 1€ a été conçue pour apporter aux utilisateurs un maximum de flexibilité et d'élasticité dans la consommation de leurs ressources », explique Ikoula Mais que r...

    Read the article

  • Oracle Linux 6 Implementation Essentials Certification Exam Now Available

    - by Antoinette O'Sullivan
    Get proof of your linux system administration skills by taking the Oracle Linux 6 Implementation Essentials Certification exam. This certification is available to all candidates. Oracle Partner Members earning this certification will be recognized as OPN Certified Specialists. This certification takes under 3 hours, asking you between 120-150 questions on areas including: Introduction to Oracle Linux Installing Oracle Linux 6 Linux Boot Process Oracle Linux System Configuration and Process Management Oracle Linux Package Management Ksplice Zero Downtime Updates Automate Tasks and System Logging User and Group Administration Oracle Linux File Sytems and Storage Administration Network Administration Oracle Linux System Monitoring and Troubleshooting Oracle Certifications are among the most sought after badges of credibility for expertise in the Information Technology marketplace. See Benefits of Oracle Certification for more information. To prepare for this exam, you can take the Oracle Linux System Administration training.

    Read the article

  • How do I change which audio jacks are used for input and output?

    - by yamaha1996
    I'm using a Realtek HD audio card built-in my motherboard. The Windows driver comes with a control panel that allows me to select which back panel jacks are used for what. So for example I can make both the blue jack and green jack for output and only the red one for mic-in. (Whereas by default, the blue jack is for line in, which I never need.) How can I do the same under Linux? If possible, please don't suggest something that involves PulseAudio or JACK; I'd like to do it the plain way, e.g. by editing ALSA configuration files, if possible. The way I understand it, my problem should have nothing to do with software servers redirecting streams, just instructing the driver to treat this jack as so and so because it's hardware supported. Thank you very much!

    Read the article

  • Dlink DWA-556 Access point fails to start on 2.6.35-25 while 2.6.35-24 works. How can I do this with >2.6.35-24?

    - by Azendale
    I'm using hostapd to run an access point with a Dlink DWA-556 wireless N card. However, I can no longer get it to start when I use kernels greater than 2.6.35-24. Here's a log where I ran the uname -a&&hostapd -c <configfile> on the different kernel versions. Linux erikbandersen 2.6.35-24-generic #42-Ubuntu SMP Thu Dec 2 02:41:37 UTC 2010 x86_64 GNU/Linux Configuration file: hostapd.conf ctrl_interface_group=0 Opening raw packet socket for ifindex 248 BSS count 1, BSSID mask ff:ff:ff:ff:ff:ff (0 bits) SIOCGIWRANGE: WE(compiled)=22 WE(source)=21 enc_capa=0xf nl80211: Added 802.11b mode based on 802.11g information HT40: control channel: 2 secondary channel: 6 RATE[0] rate=10 flags=0x2 RATE[1] rate=20 flags=0x6 RATE[2] rate=55 flags=0x6 RATE[3] rate=110 flags=0x6 RATE[4] rate=60 flags=0x0 RATE[5] rate=90 flags=0x0 RATE[6] rate=120 flags=0x0 RATE[7] rate=180 flags=0x0 RATE[8] rate=240 flags=0x0 RATE[9] rate=360 flags=0x0 RATE[10] rate=480 flags=0x0 RATE[11] rate=540 flags=0x0 Passive scanning not supported Mode: IEEE 802.11g Channel: 2 Frequency: 2417 MHz Flushing old station entries Deauthenticate all stations Using interface wlan1 with hwaddr 1c:bd:b9:d5:e8:3c and ssid 'erikbandersen.com/freewifi' wlan1: Setup of interface done. MGMT (TX callback) ACK Malformed netlink message: len=436 left=256 plen=420 256 extra bytes in the end of netlink message MGMT (TX callback) ACK mgmt::proberesp cb MGMT (TX callback) ACK mgmt::proberesp cb MGMT (TX callback) ACK mgmt::proberesp cb mgmt::auth authentication: STA=3c:4a:92:0e:41:2f auth_alg=0 auth_transaction=1 status_code=0 wep=0 New STA wlan1: STA 3c:4a:92:0e:41:2f IEEE 802.11: authentication OK (open system) wlan1: STA 3c:4a:92:0e:41:2f MLME: MLME-AUTHENTICATE.indication(3c:4a:92:0e:41:2f, OPEN_SYSTEM) wlan1: STA 3c:4a:92:0e:41:2f MLME: MLME-DELETEKEYS.request(3c:4a:92:0e:41:2f) authentication reply: STA=3c:4a:92:0e:41:2f auth_alg=0 auth_transaction=2 resp=0 (IE len=0) MGMT (TX callback) ACK mgmt::auth cb wlan1: STA 3c:4a:92:0e:41:2f IEEE 802.11: authenticated mgmt::assoc_req association request: STA=3c:4a:92:0e:41:2f capab_info=0x421 listen_interval=10 Validating WMM IE: OUI 00:50:f2 OUI type 2 OUI sub-type 0 version 1 QoS info 0x0 HT: STA 3c:4a:92:0e:41:2f HT Capabilities Info: 0x102c handle_assoc STA 3c:4a:92:0e:41:2f - no greenfield, num of non-gf stations 1 handle_assoc STA 3c:4a:92:0e:41:2f - 20 MHz HT, num of 20MHz HT STAs 1 hostapd_ht_operation_update current operation mode=0x0 hostapd_ht_operation_update new operation mode=0x7 changes=2 new AID 1 wlan1: STA 3c:4a:92:0e:41:2f IEEE 802.11: association OK (aid 1) MGMT (TX callback) ACK mgmt::assoc_resp cb wlan1: STA 3c:4a:92:0e:41:2f IEEE 802.11: associated (aid 1) wlan1: STA 3c:4a:92:0e:41:2f MLME: MLME-ASSOCIATE.indication(3c:4a:92:0e:41:2f) wlan1: STA 3c:4a:92:0e:41:2f MLME: MLME-DELETEKEYS.request(3c:4a:92:0e:41:2f) wlan1: STA 3c:4a:92:0e:41:2f RADIUS: starting accounting session 4DAC8224-00000000 MGMT (TX callback) ACK mgmt::action cb MGMT (TX callback) ACK mgmt::proberesp cb MGMT (TX callback) ACK mgmt::proberesp cb MGMT (TX callback) ACK mgmt::proberesp cb MGMT (TX callback) ACK mgmt::proberesp cb MGMT (TX callback) ACK mgmt::proberesp cb Signal 2 received - terminating wlan1: STA 3c:4a:92:0e:41:2f MLME: MLME-DEAUTHENTICATE.indication(3c:4a:92:0e:41:2f, 1) wlan1: STA 3c:4a:92:0e:41:2f MLME: MLME-DELETEKEYS.request(3c:4a:92:0e:41:2f) Removing station 3c:4a:92:0e:41:2f hostapd_ht_operation_update current operation mode=0x7 hostapd_ht_operation_update new operation mode=0x0 changes=2 Flushing old station entries Deauthenticate all stations . Linux erikbandersen 2.6.35-25-generic #44-Ubuntu SMP Fri Jan 21 17:40:44 UTC 2011 x86_64 GNU/Linux Configuration file: hostapd.conf ctrl_interface_group=0 Opening raw packet socket for ifindex 248 BSS count 1, BSSID mask ff:ff:ff:ff:ff:ff (0 bits) SIOCGIWRANGE: WE(compiled)=22 WE(source)=21 enc_capa=0xf nl80211: Added 802.11b mode based on 802.11g information Allowed channel: mode=1 chan=1 freq=2412 MHz max_tx_power=27 dBm Allowed channel: mode=1 chan=2 freq=2417 MHz max_tx_power=27 dBm Allowed channel: mode=1 chan=3 freq=2422 MHz max_tx_power=27 dBm Allowed channel: mode=1 chan=4 freq=2427 MHz max_tx_power=27 dBm Allowed channel: mode=1 chan=5 freq=2432 MHz max_tx_power=27 dBm Allowed channel: mode=1 chan=6 freq=2437 MHz max_tx_power=27 dBm Allowed channel: mode=1 chan=7 freq=2442 MHz max_tx_power=27 dBm Allowed channel: mode=1 chan=8 freq=2447 MHz max_tx_power=27 dBm Allowed channel: mode=1 chan=9 freq=2452 MHz max_tx_power=27 dBm Allowed channel: mode=1 chan=10 freq=2457 MHz max_tx_power=27 dBm Allowed channel: mode=1 chan=11 freq=2462 MHz max_tx_power=27 dBm Allowed channel: mode=0 chan=1 freq=2412 MHz max_tx_power=27 dBm Allowed channel: mode=0 chan=2 freq=2417 MHz max_tx_power=27 dBm Allowed channel: mode=0 chan=3 freq=2422 MHz max_tx_power=27 dBm Allowed channel: mode=0 chan=4 freq=2427 MHz max_tx_power=27 dBm Allowed channel: mode=0 chan=5 freq=2432 MHz max_tx_power=27 dBm Allowed channel: mode=0 chan=6 freq=2437 MHz max_tx_power=27 dBm Allowed channel: mode=0 chan=7 freq=2442 MHz max_tx_power=27 dBm Allowed channel: mode=0 chan=8 freq=2447 MHz max_tx_power=27 dBm Allowed channel: mode=0 chan=9 freq=2452 MHz max_tx_power=27 dBm Allowed channel: mode=0 chan=10 freq=2457 MHz max_tx_power=27 dBm Allowed channel: mode=0 chan=11 freq=2462 MHz max_tx_power=27 dBm HT40: control channel: 2 secondary channel: 6 RATE[0] rate=10 flags=0x2 RATE[1] rate=20 flags=0x6 RATE[2] rate=55 flags=0x6 RATE[3] rate=110 flags=0x6 RATE[4] rate=60 flags=0x0 RATE[5] rate=90 flags=0x0 RATE[6] rate=120 flags=0x0 RATE[7] rate=180 flags=0x0 RATE[8] rate=240 flags=0x0 RATE[9] rate=360 flags=0x0 RATE[10] rate=480 flags=0x0 RATE[11] rate=540 flags=0x0 Passive scanning not supported Mode: IEEE 802.11g Channel: 2 Frequency: 2417 MHz Could not set channel for kernel driver wlan1: Unable to setup interface. My wireless card is listed as 02:00.0 Network controller: Atheros Communications Inc. AR5008 Wireless Network Adapter (rev 01) by lspci. Am I doing it wrong and there's a new way of doing it? I'm holding off upgrading to Natty because of this. What changed between the versions that would cause this? Should I report it as a bug?

    Read the article

  • Ubuntu 14.04.1 will not load - stops in tty1

    - by Mitya Stiglitz
    I was following some "guides" on how to clean my system and have cleaned it so well that it doesn't work anymore. Example: in synaptic, I completely removed all packages in "Not installed: residual configuration" and a ton of other packages I "don't need". I know this has probably been asked a trillion times but I really need to find out how to get back to the working OS I had about two hours ago. One hour of googling has not helped me, so I am asking here. When I start Ubuntu, usually nothing happens for quite some time and then tty1 starts. I can log in normally, but I don't know how to proceed from there. I can do: less /var/log/apt/history.log and get a log, but I don't know how to get started with this...

    Read the article

  • Webmaster Tools - URL Parameters Settings Do Not Work

    - by David
    Google Webmaster Tools shows problems with duplicate title tags under Optimization - HTML Improvements, for example: ???????? Mitsubishi Electric Mr. Slim PC Series PC-3KAKLT (220V) 30000 BTU > /????-????/mitsubishi-mr-slim-pc3kaklt-30000-btu.html > /????-????/mitsubishi-mr-slim-pc3kaklt-30000-btu.html?category_id=96 These two pages have exactly the same content, a rel-canonical tag is set, and they are (no longer) linked to internally. Additionally, we used the Configuration - URL Parameters setting, to set this parameter to No: Doesn't affect page content about one month ago. However, Google is still showing these HTML improvements (and rankings dropped dramatically). What else can we do here? Best, David

    Read the article

  • Configurer un module Scaime eNod3-C en CANopen sur M340 en Unity, par Bruno Guérangé

    Contrairement à la série TSX57 Premium, la gamme M340 de Schneider ne comporte pas de carte de pesage. Pour ajouter des voies de pesage sur une configuration il faut donc installer et raccorder des modules externes sur l'automate. Nous avons donc cherché des modules raccordables sur le réseau CANopen, CANopen est un bus de terrain ouvert et rapide, de plus il est intégré de série sur certaines CPU de la gamme M340. Un des modules connectable sur le réseau CANopen est le transmetteur de pesage Scaime eNod3-C. Scaime est une marque reconnue dans le domaine du pesage et le module eNod3-C présente de très bonnes caractéristiques de mesure et filtrage. ...

    Read the article

  • AFP and SAMBA shares are confusing my MacOS X Lion

    - by Pierre
    I've setup my file server running ubuntu 12.04 with AFP/Avahi and Samba shares. Simple configuration, nothing too complicated. I've given my AFP machine a different name than %h to avoid confusion when looking into my Finder. However, my mac os lion mbp still confuses the two and the only way to access the AFP shares is via direct connect to IP address. The samba machine name seems to be hardwired to hostname (I can only see that that workgroup can be changed). Is there anything I am missing or obvious that I need to set? Best regards and thank you in advanced Pierre

    Read the article

  • Forked-daapd with alternative soundcard

    - by Mah
    I am trying to configure forked-daapd on my computer, and everything goes well except that in configuration file I can not set a new value for the line corresponding to soundcard. This is the default code in the config file: #card = "default" I want to use a soundcard called "DG2", which is the soundcard no.1 and has a first device that ALSA recognizes as no.0. So, I change the line to the following: card = "hw:DG2,0" I restart the daapd service and the next time I play a file through iTune remote, I get a message in my server log file saying that it can not play the file because the device is busy. Any change in the device name will return a different error, saying that the device does not exist. I am pretty sure no other uses this external device, and I don't understand why I get this message. I have tried hwplug as well, with no result.

    Read the article

  • Is running "milli"-benchmarks a good idea?

    - by Konstantin Weitz
    I just came across the Caliper project and it looks very nice. Reading the introduction to microbenchmarks, one gets the feeling that the developers would not suggest to use the framework if the benchmark takes longer than a second or so. I looked at the code and it looks like a RuntimeOutOfRangeException is actually thrown if a scenario takes longer than 10s to execute. Could you explain to me what the problems are with running larger benchmarks? My motivation for using Caliper was to compare two join-algorithm implementations. Those will definitely run for quite some time and will do some disk IO, yet running the entire database would make it hard to do the comparison, because the configuration of the algorithms and the visualization of the results would be a pain.

    Read the article

< Previous Page | 495 496 497 498 499 500 501 502 503 504 505 506  | Next Page >