Search Results

Search found 6575 results on 263 pages for 'cscript exe'.

Page 5/263 | < Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >

  • Windows cmd.exe output in PowerShell

    - by noledgeispower
    I have a script for remotely executing commands on other machines, however... when using windows cmd.exe commands It does not write to the file on the remote server. Here is the code. $server = 'serverName' $Username = 'userName' $Password = 'passWord' $cmd = "cmd /c ipconfig" ######################## ######################## $ph = "C:\mPcO.txt" $rph = "\\$server\C$\mPcO.txt" $cmde = "$cmd > $ph" $pass = ConvertTo-SecureString -AsPlainText $Password -Force $mycred = new-object -typename System.Management.Automation.PSCredential -argumentlist "$Username",$pass Invoke-WmiMethod win32_process -name create -ComputerName $server -ArgumentList $cmde Credential $mycred cmd /c net use \\$server\C$ $password /USER:$username Get-Content $rph Remove-Item $rph cmd /c net use \\$server\C$ /delete As you can see we simply write $cmde = "$cmd > $ph" if I use a PowerShell command I use $cmde = "$cmd | Out-File $ph" and it works fine. Any advice Appreciated

    Read the article

  • Merging 3 apps - 2.msi and 1.exe

    - by Netguy
    EXACT duplicate of Combining three MSI into a single installer Hi Guys , I am having 3 files - Alky for Applications.msi ( which make Vista Apps work on XP) 2. Windows VIsta sidebar.exe ( Which make that VIsta sidebar work on XP) *3.Gadget Extractor.ms*i ( A part of number 2) Now , the problem is that all the 3 applications are installers and I want to merge them to 1 installer . So please tell me what should I do and I also want to remove some content( normal files) from 2. Note: I do NOT want to bind the files , so that 3 installers start at the same time. I want to make them into one The Person who is able to help me gets a VPS with cPanel with RL/TF allowed :D

    Read the article

  • BizTalk - Removing BAM Activities and Views using bm.exe

    - by Stuart Brierley
    Originally posted on: http://geekswithblogs.net/StuartBrierley/archive/2013/10/16/biztalk---removing-bam-activities-and-views-using-bm.exe.aspxOn the project I am currently working on, we are making quite extensive use of BAM within our growing number of BizTalk applications, all of which are being deployed and undeployed using the excellent Deployment Framework for BizTalk 5.0.Recently I had an issue where problems on the build server had left the target development servers in a state where the BAM activities and views for a particular application were not being removed by the undeploy process and unfortunately the definition in the solution had changed meaning that I could not easily recreate the file from source control.  To get around this I used the bm.exe application from the command line to manually remove the problem BAM artifacts - bm.exe can be found at the following path:C:\Program Files (x86)\Microsoft BizTalk Server 2010\TrackingC:\Program Files (x86)\Microsoft BizTalk Server 2010\TrackingStep1 :Get the BAM Definition FileRun the following command to get the BAm definition file, containing the details of all the activities, views and alerts:bm.exe get-defxml -FileName:{Path and File Name Here}.xmlStep 2: Remove the BAM ArtifactsAt this stage I chose to manually remove each of my problem BAM activities and views using seperate command line calls.  By looking in the definition file I could see the names of the activities and views that I wanted to remove and then use the following commands to remove first the views and then the activities:bm.exe remove-view -name:{viewname}bm.exe remove-activity -name:{activityname}

    Read the article

  • xsd.exe creating invalid constraints in dataset from xsd file

    - by Dan Neely
    I have a sequence with an allowed minimum length of zero in my xsd. When I try and load an xml file which doesn't have any elements of the sequence into the DataSet that xsd.exe created I get an exception indicating that my file violated one of the DataSet's constraints. The xml file validates against the schema so I know it's valid. Is there anything I can do to make the tool generate a valid dataset? <xs:sequence minOccurs="0" maxOccurs="unbounded"> <xs:element name="Numbers" type="xs:double"/> </xs:sequence> Edit: if I change my schema to this the generated code works properly. It looks wrong to me though since it appears to be implying that I could have sequence items with nothing in them, which doesn't make any sense. <xs:sequence minOccurs="0" maxOccurs="unbounded"> <xs:element name="Numbers" type="xs:double" minOccurs="0"/> </xs:sequence>

    Read the article

  • Windows 7: Touch gestures in IE not working without explorer.exe being run once

    - by Michael
    Details: Internet Explorer 9 and Windows 7 Professional, running on a HP TouchSmart (touch screen PC). It is going to be a kiosk PC (running a custom GUI for displaying websites). Scenario 1: When running Internet Explorer as a normal program in Windows 7, touch functions work perfectly. I can scroll the website by dragging it with my finger, I can pinch zoom and I can touch-and-hold right click. I now change the default shell in Windows to Internet Explorer (ie. IE starts instead of explorer.exe). Internet Explorer of course starts up when logging in. However, touch functions are reduced to basic clicking (no dragging, no pinch zooming, no touch-and-hold right click). Then I manually start explorer.exe, and the touch functions work again! And here is the weird part: When I kill explorer.exe, the touch functions keeps working - even if I close IE and start a new instance. Scenario 2: The exact same, but instead of changing the default shell to Internet Explorer, I change it to my own program, which uses an embedded Internet Explorer ("WebBrowser"). Same thing happens. What I've tried: Autorun programs: When explorer.exe launches, it launches all the autorun programs. There are no relevant programs being run by explorer, but just in case, I have manually started all the autorun programs, so that it is identical (but without explorer.exe) to a normal login. It still does not work (until I launch explorer.exe). Specifically TabTip.exe, TabTip32.exe and wisptis.exe are all running. All services are also started. To sum it up Running explorer.exe once changes something in the touch capabilities of Internet Explorer. It doesn't matter if explorer.exe is running - as long as it has been run once. Does anyone know what causes this behavior? Or how I can circumvent it neatly? Thanks!

    Read the article

  • Deserializing classes from XML generated using XSD.exe

    - by heap
    I have classes generated (using xsd.exe) from an .xsd that I can serialize just fine, but when I try and deserialize it, I get the error: {"<XMLLanguages xmlns='http://tempuri.org/XMLLanguages.xsd'> was not expected."} I've searched for a couple of hours and found most peoples problems lie in not declaring namespaces in their xsd/xml, not defining namespaces in their classes, etc, but I can't find a solution for my problem. Here are code snippets for the relevant classes. <?xml version="1.0" encoding="utf-8"?> <xs:schema id="SetupData" targetNamespace="http://tempuri.org/XMLLanguages.xsd" elementFormDefault="qualified" xmlns="http://tempuri.org/XMLLanguages.xsd" xmlns:xs="http://www.w3.org/2001/XMLSchema" > <xs:element name="XMLLanguages"> <xs:complexType> <xs:sequence> <xs:element name="Tier" minOccurs="1" maxOccurs="unbounded"> <xs:complexType> <xs:sequence> <xs:element name="L" minOccurs="1" maxOccurs="unbounded" type="Language"/> </xs:sequence> <xs:attribute name="TierID" type="xs:int"/> </xs:complexType> </xs:element> </xs:sequence> </xs:complexType> </xs:element> <xs:complexType name="Language"> <xs:sequence> <xs:element name="LangID" type="xs:int"/> <xs:element name="Tier" type="xs:int"/> <xs:element name ="Name" type="xs:string"/> </xs:sequence> <xs:attribute name ="PassRate" type="xs:int"/> </xs:complexType> </xs:schema> And the class: /// <remarks/> [System.CodeDom.Compiler.GeneratedCodeAttribute("xsd", "4.0.30319.1")] [System.SerializableAttribute()] [System.Diagnostics.DebuggerStepThroughAttribute()] [System.ComponentModel.DesignerCategoryAttribute("code")] [System.Xml.Serialization.XmlTypeAttribute(Namespace = "http://tempuri.org/XMLLanguages.xsd")] [System.Xml.Serialization.XmlRootAttribute(Namespace = "http://tempuri.org/XMLLanguages.xsd", IsNullable = false)] public partial class XMLLanguages { private List<XMLLanguagesTier> tierField; /// <remarks/> [System.Xml.Serialization.XmlElementAttribute("Tier")] public List<XMLLanguagesTier> Tiers { get { return this.tierField; } set { this.tierField = value; } } } And a the line in XML causing the error: <XMLLanguages xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xsd="http://www.w3.org/2001/XMLSchema" xmlns="http://tempuri.org/XMLLanguages.xsd">

    Read the article

  • Touch gestures in IE not working without explorer.exe being run once

    - by Michael
    Edit: Rephrasing my question: Upon further troubleshooting, I can conclude that: Touch gestures (dragging, pinch to zoom, touch-and-hold right click) in Internet Explorer start to work when: The system has been running for ~2 minutes. This coincides with the delayed start of services. Explorer.exe is being run, then killed. I assume Explorer.exe starts some services? The services with delayed start are as follows: Security Center Software Protection Windows Defender, Search and Update Windows Font Cache Service Microsoft .NET Framework NGEN v4.0.30319_X64 and X86 I see no connection between these services and touch gestures, but just in case, I manually tried starting these services, but without luck. What else happens delayed after system boot, which also happens when explorer is started? Old question: Details: Internet Explorer 9 and Windows 7 Professional, running on a HP TouchSmart (touch screen PC). It is going to be a kiosk PC (running a custom GUI for displaying websites). Scenario 1: When running Internet Explorer as a normal program in Windows 7, touch functions work perfectly. I can scroll the website by dragging it with my finger, I can pinch zoom and I can touch-and-hold right click. I now change the default shell in Windows to Internet Explorer (ie. IE starts instead of explorer.exe). Internet Explorer of course starts up when logging in. However, touch functions are reduced to basic clicking (no dragging, no pinch zooming, no touch-and-hold right click). Then I manually start explorer.exe, and the touch functions work again! And here is the weird part: When I kill explorer.exe, the touch functions keeps working - even if I close IE and start a new instance. Scenario 2: The exact same, but instead of changing the default shell to Internet Explorer, I change it to my own program, which uses an embedded Internet Explorer ("WebBrowser"). Same thing happens. What I've tried: Autorun programs: When explorer.exe launches, it launches all the autorun programs. There are no relevant programs being run by explorer, but just in case, I have manually started all the autorun programs, so that it is identical (but without explorer.exe) to a normal login. It still does not work (until I launch explorer.exe). Specifically TabTip.exe, TabTip32.exe and wisptis.exe are all running. All services are also started. To sum it up Running explorer.exe once changes something in the touch capabilities of Internet Explorer. It doesn't matter if explorer.exe is running - as long as it has been run once. Does anyone know what causes this behavior? Or how I can circumvent it neatly?

    Read the article

  • WiX 3 Tutorial: Generating file/directory fragments with Heat.exe

    - by Mladen Prajdic
    In previous posts I’ve shown you our SuperForm test application solution structure and how the main wxs and wxi include file look like. In this post I’ll show you how to automate inclusion of files to install into your build process. For our SuperForm application we have a single exe to install. But in the real world we have 10s or 100s of different files from dll’s to resource files like pictures. It all depends on what kind of application you’re building. Writing a directory structure for so many files by hand is out of the question. What we need is an automated way to create this structure. Enter Heat.exe. Heat is a command line utility to harvest a file, directory, Visual Studio project, IIS website or performance counters. You might ask what harvesting means? Harvesting is converting a source (file, directory, …) into a component structure saved in a WiX fragment (a wxs) file. There are 2 options you can use: Create a static wxs fragment with Heat and include it in your project. The pro of this is that you can add or remove components by hand. The con is that you have to do the pro part by hand. Automation always beats manual labor. Run heat command line utility in a pre-build event of your WiX project. I prefer this way. By always recreating the whole fragment you don’t have to worry about missing any new files you add. The con of this is that you’ll include files that you otherwise might not want to. There is no perfect solution so pick one and deal with it. I prefer using the second way. A neat way of overcoming the con of the second option is to have a post-build event on your main application project (SuperForm.MainApp in our case) to copy the files needed to be installed in a special location and have the Heat.exe read them from there. I haven’t set this up for this tutorial and I’m simply including all files from the default SuperForm.MainApp \bin directory. Remember how we created a System Environment variable called SuperFormFilesDir? This is where we’ll use it for the first time. The command line text that you have to put into the pre-build event of your WiX project looks like this: "$(WIX)bin\heat.exe" dir "$(SuperFormFilesDir)" -cg SuperFormFiles -gg -scom -sreg -sfrag -srd -dr INSTALLLOCATION -var env.SuperFormFilesDir -out "$(ProjectDir)Fragments\FilesFragment.wxs" After you install WiX you’ll get the WIX environment variable. In the pre/post-build events environment variables are referenced like this: $(WIX). By using this you don’t have to think about the installation path of the WiX. Remember: for 32 bit applications Program files folder is named differently between 32 and 64 bit systems. $(ProjectDir) is obviously the path to your project and is a Visual Studio built in variable. You can view all Heat.exe options by running it without parameters but I’ll explain some that stick out the most. dir "$(SuperFormFilesDir)": tell Heat to harvest the whole directory at the set location. That is the location we’ve set in our System Environment variable. –cg SuperFormFiles: the name of the Component group that will be created. This name is included in out Feature tag as is seen in the previous post. -dr INSTALLLOCATION: the directory reference this fragment will fall under. You can see the top level directory structure in the previous post. -var env.SuperFormFilesDir: the name of the variable that will replace the SourceDir text that would otherwise appear in the fragment file. -out "$(ProjectDir)Fragments\FilesFragment.wxs": the full path and name under which the fragment file will be saved. If you have source control you have to include the FilesFragment.wxs into your project but remove its source control binding. The auto generated FilesFragment.wxs for our test app looks like this: <?xml version="1.0" encoding="utf-8"?><Wix xmlns="http://schemas.microsoft.com/wix/2006/wi"> <Fragment> <ComponentGroup Id="SuperFormFiles"> <ComponentRef Id="cmp5BB40DB822CAA7C5295227894A07502E" /> <ComponentRef Id="cmpCFD331F5E0E471FC42A1334A1098E144" /> <ComponentRef Id="cmp4614DD03D8974B7C1FC39E7B82F19574" /> <ComponentRef Id="cmpDF166522884E2454382277128BD866EC" /> </ComponentGroup> </Fragment> <Fragment> <DirectoryRef Id="INSTALLLOCATION"> <Component Id="cmp5BB40DB822CAA7C5295227894A07502E" Guid="{117E3352-2F0C-4E19-AD96-03D354751B8D}"> <File Id="filDCA561ABF8964292B6BC0D0726E8EFAD" KeyPath="yes" Source="$(env.SuperFormFilesDir)\SuperForm.MainApp.exe" /> </Component> <Component Id="cmpCFD331F5E0E471FC42A1334A1098E144" Guid="{369A2347-97DD-45CA-A4D1-62BB706EA329}"> <File Id="filA9BE65B2AB60F3CE41105364EDE33D27" KeyPath="yes" Source="$(env.SuperFormFilesDir)\SuperForm.MainApp.pdb" /> </Component> <Component Id="cmp4614DD03D8974B7C1FC39E7B82F19574" Guid="{3443EBE2-168F-4380-BC41-26D71A0DB1C7}"> <File Id="fil5102E75B91F3DAFA6F70DA57F4C126ED" KeyPath="yes" Source="$(env.SuperFormFilesDir)\SuperForm.MainApp.vshost.exe" /> </Component> <Component Id="cmpDF166522884E2454382277128BD866EC" Guid="{0C0F3D18-56EB-41FE-B0BD-FD2C131572DB}"> <File Id="filF7CA5083B4997E1DEC435554423E675C" KeyPath="yes" Source="$(env.SuperFormFilesDir)\SuperForm.MainApp.vshost.exe.manifest" /> </Component> </DirectoryRef> </Fragment></Wix> The $(env.SuperFormFilesDir) will be replaced at build time with the directory where the files to be installed are located. There is nothing too complicated about this. In the end it turns out that this sort of automation is great! There are a few other ways that Heat.exe can compose the wxs file but this is the one I prefer. It just seems the clearest. Play with its options to see what can it do. It’s one awesome little tool.   WiX 3 tutorial by Mladen Prajdic navigation WiX 3 Tutorial: Solution/Project structure and Dev resources WiX 3 Tutorial: Understanding main wxs and wxi file WiX 3 Tutorial: Generating file/directory fragments with Heat.exe

    Read the article

  • How to solve "catastrophic failure" with 32-bit COM component in SysWOW64\cscript or wscript

    - by kcrumley
    I'm trying to run a VBScript script that uses a 7-year-old 3rd-party 32-bit COM component on Windows Server 2008 R2, with the command-line 32-bit script host, SysWOW64\cscript.exe. When I call CreateObject on the class, it appears to be successful, but the very first time I try to use a property or method (I've tried several different ones) on the object, it gives me the "catastrophic failure". I have identical results with SysWOW64\wscript.exe, except, of course, that my error message comes in a msgbox instead of the command-line window. I think this has to do specifically with the 64-bit scripting hosts because of the following: The equivalent Classic ASP script, calling the same component and using 95% of the same code, works correctly on the same server, with IIS configured to support 32-bit COM. The same VBScript works correctly on a 32-bit Windows XP machine and a 32-bit Windows Server 2003 machine. The component fails in exactly the same way on my 64-bit Windows 7 machine. My Google searches for solutions to this problem have mostly turned up a lot of different problems that were solved by putting the COM component into a toolbar in Visual Studio. Obviously, that solution doesn't apply here. My questions are: Is there a core problem that is always behind a "catastrophic failure" from a Windows scripting host calling a COM component? Is there a place in a configuration snap-in, or in the registry, where I need to make a change similar to the change I had to make to the IIS Application pool to "Enable 32-bit Applications"? Is there a general place in the Server 2008 R2 Event Viewer that I should be looking, to see if there are any more details on the failure, in case it turns out to be specific to this component? Thanks in advance.

    Read the article

  • Space in Directory Parameter of svcutil.exe

    - by Drew Frisk
    I'm attempting to download metadata for a WCF service using svcutil but I'm running into issues with the /directory:< parameter. The directory I want to save to has a space in it: C:\Service References\Logging so when I execute /t:metadata I receive the following error: Error: The directory 'C:\Program Files (x86)\Microsoft SDKs\Windows\v8.0A\bin\NETFX 4.0 Tools\References\Logging' could not be found. Verify that the directory exists and that you have the appropriate permissions to read it. It looks to me like the space in "Service References" is causing the issue. From my understanding of command shell (which is very little) spaces act as delimiters for an executable. So I tried escaping the space with a carrot Service^ References and surrounding the path in double quotes "C:\Service References\Logging" but neither of those seem to be working, as the /directory: parameter doesn't recognize them as valid characters in the value. I haven't been able to find any direction in regards to this and svcutil, so I'm at a loss right now. I could download the files to a temp folder and then move them, but I would prefer not to take that approach. I would appreciate any direction that could be given on trying to resolve this. Thanks in advance.

    Read the article

  • Will running aspnet_regiis.exe -ir create any problems?

    - by alexander-strandberg
    Hi there. I've asked a question about changing the version of .Net sites in the IIS. If it affects classic asp sites etc (See Does asp.net setting affect classic asp (IIS 6 settings)) And that seems fine. So my follow-up question is, will running this command get me fired? What it does is changing the default value (and all existing?) of the .net version to 2.0. This wont affect any of the .net sites since they're allready versioned to 2.0. The classic asp pages needs to get its app pools updated so its functionoal with 2.0 but may I run into any other troubles? I've tried doing this on a test environment and no sites whet down during the installation period (from the command) but I did not have any classic asp sites or any .net sites running though (which I should test, come to think about it) but may something else break? Is this command doing anything else? We have some very large sites running and we cannot have downtime periods so I need to be 100% sure that this command is safe. Since all sites go down everytime we change a new sites .net version number we need to get this fix live asap. Any good ideas?

    Read the article

  • Modify cmd.exe properties using the command prompt

    - by CodexArcanum
    Isn't that nicely recursive? I've got a portable command prompt on my external drive, and it has a nice .bat file to configure some initial settings, but I'd like more! Here's what I know how to set from .bat: Colors = (color XY) where x and y are hex digits for the predefined colors Prompt = (prompt $p$g) sets the prompt to "C:\etc\etc " the default prompt Title = (title "text") sets the window title to "text" Screen Size = (mode con: cols=XX lines=YY) sets the columns and lines size of the window Path = (SET PATH=%~d0\bin;%PATH%) sets up local path to my tools and appends the computer's path So that's all great. But there are a few settings I can't seem to set from the bat. Like, how would I set these up wihtout using the Properties dialogue: Buffer = not screen size, but the buffer Options like quick edit mode and autocomplete Popup colors Font. And can you use a font on the portable drive, or must it be installed to work? Command history options

    Read the article

  • XSD.exe question about include files and code generation

    - by Roger Willcocks
    If you have an XSD with an includes reference. Is it possible to generate 2 separate class files. 1 for the XSD, and 1 for the included XSD? My Scenario 4 XSDs, each of which share 15-20 element definitions in common. Rather than maintaining, I'd like to end up with the 4 XSDs all referencing a fifth file with the common definitions, and code generating 5 .cs files to use.

    Read the article

  • Open + Save .exe file in notepad makes it corrupted

    - by Jacob Kofoed
    Hi, I just published this simple console application that is supposed to show a textbox with the value of a setting called "userID" with value 1001. This works like a charm. Now what I need is to change this value outside the editor, from notepad etc. When I open the application a lot in there is non-sence (& o! -å Þþþ,o" Ü+) etc. but with a quick (ctrl + F) I found the value 1001, and changed this to some other integer. I ran the application again, and it failed, didn't even give any userful error-message. At a point I tried just opening a newly published non-corrupted version of the application, didn't change anything, then saved from notepad, and it were also corrupted. It seems like notepad can't open some characters or something. Do I need to publish the application in some specific text-unicode language or something? Help much appreciated :) I know it sounds like a stupid application, but it is just a test of concept :) I use vb.net for this

    Read the article

  • Is it possible to build exe on Vista and deploy on XP using py2exe

    - by dfens
    I have created some program using python on Windows Vista. But I want to deploy it on Windows XP. Is it necessary to make new build on windows XP? Or there is possibility to make build that will work on both of these systems? EDIT (EDIT 2 - very simple program does not work also): My setup: from distutils.core import setup import py2exe setup(console=['orderer.py']) Using dependency explorer i checked that dependencies are: msvcr90.dll kernel32.dll +ntdll.dll

    Read the article

  • How to find which w3wp.exe to attach when debugging your SharePiont2010 project

    - by ybbest
    When debugging SharePoint2010 project, you need to attach w3wp.exe process, however there are often quite a few of them and it is very hard to figure out which one to attach. Today, I will show you how to find out which process to attach using a tool called process explorer. 1. Download the process explorer and run it after you download it. 2. Find the w3wp.exe processes under wininit.exe right-click the columns header and click Select Columns. 3. Include Command Line under Process Image. 4. Now you can see your IIS site name next to w3wp.exe, in my case I’d like to attach the “SharePoint – BenDev80″.You can see the PID of the process is 2920. 5. From the above process you know the process ID you’d like to attach is 2920, you can then go ahead to attach the process from Visual Studio.

    Read the article

  • Redirecting to a diferent exe for download based on user agent

    - by Ra
    I own a Linux-Apache site where I host exe files for download. Now, when a user clicks this link to my site (published on another site): http://mysite.com/downloads/file.exe I need to dynamically check their user agent and redirect them to either http://mysite.com/downloads/file-1.exe or http://mysite.com/downloads/file-2.exe It seems to me that I have to options: Put a .htaccess file stating that .exe files should be considered to be scripts. Then write a script that checks the user agent and redirects to a real exe placed in another folder. Call this script file.exe. Use Apache mod-rewrite to point file.exe to redirect.php. Which of these is better? Any other considerations? Thanks.

    Read the article

  • The great Vanishing Act of INetMgr.exe on my Windows 7 x64 system

    - by marc_s
    I'm facing an odd issue with the IIS Manager on Windows 7 (x64). At home, I have Win7 Professional, and when I check my IIS manager icon in the start menu, I see it links to %windir%\system32\inetsrv\InetMgr.exe When I launch this from the command line, it works like a charm. At work, however, I have Windows 7 Enterprise (x64), and when I check my link in the start menu, the entry is exactly the same. If I click on it - it works like a charm. Now if I'd like to launch it from the command line (cmd.exe or TakeCommand), however - the file just isn't there - a DIR %windir%\system32\inetsrv\*.exe shows a number of files, including a "inetmgr6.exe" - but no "inetmgr.exe" - and of course, I can't launch it either :-( Strangely enough, when I look at the directory %windir%\system32\INetSrv in Windows Explorer or Windows Powershell, I SEE the INetMgr.exe file and I can launch it - no problem. What the **** is going on here? How can I find the INetMgr.exe from my classic command line and launch it from there?? UPDATE: ok, some updates. On my work laptop, the INetMgr.exe file appears to really be located in a directory called c:\windows\syswow64\inetsrv (I'm recalling from memory, so don't quote me on the directory name - something like that). I can see this if I search for it in e.g. Powershell or Windows 7 Explorer. However, from a "classic" command line like cmd.exe, it appears to be in c:\windows\system32\inetsrv ..... hmmm.... trouble is - even though I now know where the file really is, I cannot access that directory from my classic command line - not even if I'm running cmd.exe as admin with elevated privileges....... so I know where the file is, but that still doesn't solve my problem :-(

    Read the article

  • Explorer.exe hangup during move large file into external drive

    - by PiotrK
    During move large files (700mb+) to external drive formated NTFS via USB 3.0 I've noticed strange things about explorer.exe (I am using Windows 7 up to date) Sometimes after move file the explorer get stuck (ie. it can happen after few files during move of several large files) - moving window freeze and I am unable to kill explorer (via taskmgr, or cmdline TASKKILL). In command line I've got something like this (taskmgr shows that explorer.exe is still running - I've got the same PID every time I try to kill it and no diagnostic message): C:\Windows\system32TASKKILL /F /IM explorer.exe SUKCES: proces "explorer.exe" o identyfikatorze PID 6296 zostal zakonczony. C:\Windows\system32TASKKILL /F /IM explorer.exe SUKCES: proces "explorer.exe" o identyfikatorze PID 6296 zostal zakonczony. If I try to run another explorer.exe process at this point, I got desktop icon and start bar back but I cannot open any explorer window After few minutes explorer.exe finally dies and I am able to rerun it without rebooting File that I moved have two copies - one local and one on the external drive (the original file wasn't delete after move); Both copies seems to contain the same data (same length and CRC info) If this happen during move of multiply files, only some files are moved and one of them have two copies (both locally and on the external drive) What can I do to fix those explorer hangs? Added: The same problem exist when copying files, it hangsup between large files Similar problem exist when I tried to use TotalCommander (x64): copying paused at 80% of one of files, TC didn't hung up (but clicking cancel in copying dialog box doesn't have any effect). During this pause I can't kill TotalCmd.exe just like Explorer.exe Added (2): This problem seems to disappear when I use 32 bit applications (like TotalCommander (x86) ), but I need to do more testing to be sure of this Added (3): There are several errors in event log, source: disk, id: 11, qualifiers: 49156, task: 0, level: 2, keywords: 0x80000000000000 (This may be important, and I forgot to mention this): Main disk is encrypted via Truecrypt (boot-in password)

    Read the article

  • Remote App - linked exe

    - by StaWho
    I'm experiencing below problem: I'm trying to run Microsoft NAV as remote app. There are two exe file involved: finsql.exe - main executable and finhlink.exe. Later one is used to directly run a 'window' within NAV (it takes certain link as parameter). This functionality is not present in finsql.exe. After configuring and running finhlink.exe as remote app I get an error "...finsql.exe can't be executed...". I believe it's because finhlink.exe is in fact invoking finsql.exe. Is there a way of allowing invocation of linked executable via remote app?

    Read the article

  • How to determine expected license serial number by viewing an EXE File?

    - by Steve
    I was attempting to install an exe that requires a serial number before the install, which the vendor has not provided to us yet. This got my wheels turning about whether there is any information that can be gained from viewing an exe using a hex editor/VI/etc? Using VI to view an exe, I can see some sections of plain text, but it is difficult to determine what it refers to without any context around it. Is it possible to determine any information by reading an exe? Thanks

    Read the article

  • Windows 7 Bluescreen: IRQ_NOT_LESS_OR_EQUAL | athrxusb.sys

    - by wretrOvian
    I'd left my system on last night, and found the bluescreen in the morning. This has been happening occasionally, over the past few days. Details: ================================================== Dump File : 022710-18236-01.dmp Crash Time : 2/27/2010 8:46:44 AM Bug Check String : DRIVER_IRQL_NOT_LESS_OR_EQUAL Bug Check Code : 0x000000d1 Parameter 1 : 00000000`00001001 Parameter 2 : 00000000`00000002 Parameter 3 : 00000000`00000000 Parameter 4 : fffff880`06b5c0e1 Caused By Driver : athrxusb.sys Caused By Address : athrxusb.sys+760e1 File Description : Product Name : Company : File Version : Processor : x64 Computer Name : Full Path : C:\Windows\minidump\022710-18236-01.dmp Processors Count : 2 Major Version : 15 Minor Version : 7600 ================================================== HiJackThis ("[...]" indicates removed text; full log [posted to pastebin][1]): Logfile of Trend Micro HijackThis v2.0.2 Scan saved at 8:49:15 AM, on 2/27/2010 Platform: Unknown Windows (WinNT 6.01.3504) MSInternet Explorer: Internet Explorer v8.00 (8.00.7600.16385) Boot mode: Normal Running processes: C:\Windows\DAODx.exe C:\Program Files (x86)\Asus\EPU\EPU.exe C:\Program Files\Asus\TurboV\TurboV.exe C:\Program Files (x86)\PowerISO\PWRISOVM.EXE C:\Program Files (x86)\OpenOffice.org 3\program\soffice.exe C:\Program Files (x86)\OpenOffice.org 3\program\soffice.bin D:\Downloads\HijackThis.exe C:\Program Files (x86)\uTorrent\uTorrent.exe R1 - HKCU\Software\Microsoft\Internet Explorer\[...] [...] O2 - BHO: Java(tm) Plug-In 2 SSV Helper - {DBC80044-A445-435b-BC74-9C25C1C588A9} - C:\Program Files (x86)\Java\jre6\bin\jp2ssv.dll O4 - HKLM\..\Run: [HDAudDeck] C:\Program Files (x86)\VIA\VIAudioi\VDeck\VDeck.exe -r O4 - HKLM\..\Run: [StartCCC] "C:\Program Files (x86)\ATI Technologies\ATI.ACE\Core-Static\CLIStart.exe" MSRun O4 - HKLM\..\Run: [TurboV] "C:\Program Files\Asus\TurboV\TurboV.exe" O4 - HKLM\..\Run: [PWRISOVM.EXE] C:\Program Files (x86)\PowerISO\PWRISOVM.EXE O4 - HKLM\..\Run: [googletalk] C:\Program Files (x86)\Google\Google Talk\googletalk.exe /autostart O4 - HKLM\..\Run: [AdobeCS4ServiceManager] "C:\Program Files (x86)\Common Files\Adobe\CS4ServiceManager\CS4ServiceManager.exe" -launchedbylogin O4 - HKCU\..\Run: [uTorrent] "C:\Program Files (x86)\uTorrent\uTorrent.exe" O4 - HKUS\S-1-5-19\..\Run: [Sidebar] %ProgramFiles%\Windows Sidebar\Sidebar.exe /autoRun (User 'LOCAL SERVICE') O4 - HKUS\S-1-5-19\..\RunOnce: [mctadmin] C:\Windows\System32\mctadmin.exe (User 'LOCAL SERVICE') O4 - HKUS\S-1-5-20\..\Run: [Sidebar] %ProgramFiles%\Windows Sidebar\Sidebar.exe /autoRun (User 'NETWORK SERVICE') O4 - HKUS\S-1-5-20\..\RunOnce: [mctadmin] C:\Windows\System32\mctadmin.exe (User 'NETWORK SERVICE') O4 - Startup: OpenOffice.org 3.1.lnk = C:\Program Files (x86)\OpenOffice.org 3\program\quickstart.exe O13 - Gopher Prefix: O23 - Service: @%SystemRoot%\system32\Alg.exe,-112 (ALG) - Unknown owner - C:\Windows\System32\alg.exe (file missing) O23 - Service: AMD External Events Utility - Unknown owner - C:\Windows\system32\atiesrxx.exe (file missing) O23 - Service: Asus System Control Service (AsSysCtrlService) - Unknown owner - C:\Program Files (x86)\Asus\AsSysCtrlService\1.00.02\AsSysCtrlService.exe O23 - Service: DeviceVM Meta Data Export Service (DvmMDES) - DeviceVM - C:\Asus.SYS\config\DVMExportService.exe O23 - Service: @%SystemRoot%\system32\efssvc.dll,-100 (EFS) - Unknown owner - C:\Windows\System32\lsass.exe (file missing) O23 - Service: ESET HTTP Server (EhttpSrv) - ESET - C:\Program Files\ESET\ESET NOD32 Antivirus\EHttpSrv.exe O23 - Service: ESET Service (ekrn) - ESET - C:\Program Files\ESET\ESET NOD32 Antivirus\x86\ekrn.exe O23 - Service: @%systemroot%\system32\fxsresm.dll,-118 (Fax) - Unknown owner - C:\Windows\system32\fxssvc.exe (file missing) O23 - Service: FLEXnet Licens

    Read the article

  • NServiceBus Generic Host and mqsvc.exe high CPU

    - by Michael Stephenson
    We have been doing some work with NServiceBus recently and observed some unusual behaviour which was caused by our mistake and seemed worthy of a small post.   The Scenario In our solution we were doing some standard NServiceBus stuff by pushing a message to a queue using NServiceBus.  We had a direct send/receive scenario rather than a publish/subscribe one.   The background process which was meant to collect the message and then process it was a normal NServiceBus message handler.  We would run the NServiceBus.Host.exe which would find the handler and then do the usual NServiceBus magic.   The Problem In this solution we were creating some automated tests around this module of the integration process to ensure that it would work well.  We had two tests.   Test 1 This test would start NServiceBus.Host.exe using the Process object, then seed a message to the queue via our web service façade sitting above the queue which wrapped NServiceBus.  The background process would then process the message and the test would check the message had been processed fine.   If all was well then the NServiceBus.Host.exe process was stopped.   Test 2 In test 2 we would do a very similar thing except that instead of starting the process the test would install NServiceBus.Host.exe as a windows service and then start the service before the test and once the test was executed it would stop the test.   The Results of the Tests Test 1 worked really well, however in test 2 we found that it didn’t really work at all, instead of doing the background process we were finding that between mqsvc.exe and NServiceBus.Host.exe the CPU on the machine was maxed and nothing was really happening.   The Solution After trying a few things we found it was the permissions on the queue were not set correctly.  Once this was resolved it all worked fine and CPU was not excessive and ran just like the console application.   I think the couple of take aways from this are:   Make sure you set the windows service for NserviceBus Generic Host to the right credentials When you install the generic host as a windows service then by default it will use the default windows credentials.  For any production like scenario you should be using a domain account to run the process as via the windows service. Make sure you have the queue set with the right permissions For the credentials you have used to configure the generic host as a windows service you should ensure that this user has the appropriate permissions for any queues it will interact with. Make sure you turn on the right logging configuration in NServiceBus When this wasnt working correctly we didnt know there was an issue, we were just experiencing the high CPU condition.  I am a little surprised that there wasnt something logged and that the process didnt crash.  I guess this could be by design bearing in mind that the process could be monitoring many queues.  In this point Im just saying that originally we didnt have all of the log4net logging which is available from NServiceBus turned on.  Its probably a good idea to have this turned on and configured until you are happy your solution is working fine.   Thanks to Ahmed Hashmi on my team who got this working in the end.

    Read the article

  • How to get path to current exe file on Linux?

    - by user1519221
    The code below gives current path to exe file on Linux: #include <iostream> std::string getExePath() { char result[ PATH_MAX ]; ssize_t count = readlink( "/proc/self/exe", result, PATH_MAX ); return std::string( result, (count > 0) ? count : 0 ); } int main() { std::cout << getExePath() << std::endl; return 0; } The problem is that when I run it gives me current path to exe and name of the exe, e.g.: /home/.../Test/main.exe I would like to get only /home/.../Test/ I know that I can parse it, but is there any nicer way to do that?

    Read the article

< Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >