Search Results

Search found 1554 results on 63 pages for 'sas macro'.

Page 5/63 | < Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >

  • MS Word Macro - Numeric field insertion with automatic calculation at end of page

    - by Will
    Hi, I am trying to duplicate a feature that exists in Multimate (Ashton Tate) word processor. Yes, the one that hasnt been supported for 20 years! If I can duplicate this one feature I can get all the users off MM and onto Word. The documents they create are billing documents. they consist of a descriptive paragraph of any length on the left side of the page, and a billing amount at the end of the paragraph over on the right hand side, like this (excuse the imperfect formatting).... +-----------------whole page--------------------+ |                                                                    | |    pppp-para 1-pppppppppp                   | |    p                                         p                   | |    p                                         p                   | |    p                                         p                   | |    p                                         p                   | |    p                                         p                   | |    p                                         p                   | |    pppppppppppppppppppp      $$$$$  | |                                                                    |  |                                                                    |  |    pppp-para 2-pppppppppp                   | |    p                                         p                   | |    p                                         p                   | |    p                                         p                   | |    p                                         p                   | |    p                                         p                   | |    p                                         p                   | |    pppppppppppppppppppp      $$$$$  | |                                                                    |  |                                                                    |  |                             etc                                  | +-----------------------------------------------------+ some of these bills can be a few hundred pages and have a dozen or so paragraphs on each page, which is why none of the users will leave MM until this efficient little feature can be duplicated. The thing that MM does really easily is that there is a function key that they can press at any time that will - - jump the cursor from the paragraph they are writing over to the right hand side - create a numeric field - allow them to enter a number into the numeric field - return them to the left hand side to start a new paragraph What MM also does is automatically total the numeric fields on each page and create a subtotal in the page footer. it also creates a total for the entire document and puts this in the footer of the last page. I would like to duplicate this feature in word with a macro, but have no idea where to start. Any suggestions or code would be great, thanks, will.

    Read the article

  • What is a Linux device name for RAID of sas drives?

    - by flashnik
    I have a RAID1 using Promise FastTrack TX2650 consisting of 2 SAS drives. What is a Linux device name for them? Like sda is for first sata drive. I have Windows server so I can't look it directly but need this information for smartctl usage. UPDATE. I found how to access RAID: smartctl -d scsi sdb (because I also have a SATA drive). But in this case I just get an information about just raid controller though I wantto get information about drives itself. Is it possible? Promises's control panel provides information only about their healthy status (boolean) and I want more. Mostly now I need information about temperature.

    Read the article

  • Is it normal for a SAS drive to have a few bad blocks, or should I replace my drive ASAP?

    - by Nate
    I have a drive—part of a RAID 1 mirror—that has two bad blocks. Adaptec Storage Manger e-mailed me when it detected the blocks. It shows 4 medium errors for that drive, but state is still “optimal”. This is my first time using Adaptec RAID controllers. I don’t know if an occasional bad block is normal, or if I should immediately replace that drive. Update: The drive failed later the same day! The disk subsystem is: Adaptec 6405 with ZMM (2) Seagate near-line SAS drives (ST31000424SS) The other drive hasn’t reported any bad blocks yet. I am running a consistency check.

    Read the article

  • elisp macro to write function?

    - by aaa
    hello I have written few functions, which nearly identical, save for names. For example ; x is name, such as function/paragraph/line/etc. (defun my-x-function (interactive) (mark-x) (do-more-stuff) (modify-x)) is there a way to put it automatically? I have a feeling this is what macros do, but I am not sure how to use them. you help/maybe small example would be great Thanks

    Read the article

  • Microsoft Word Macro - Exporting Word Review Comments - How do you reference the sentence related to

    - by jspeaks
    I am trying to export of a Word document review comments. I want to export the sentence selection that was commented on followed by the comment. Screen shot of the image: http://jspeaks.com/mswordcomment.png I have found code to loop through the document comments, but I cannot figure out how to reference the sentence selection that the comment was related to. The current logic is: Sub ExportComments() Dim s As String Dim cmt As Word.Comment Dim doc As Word.Document For Each cmt In ActiveDocument.Comments s = s & cmt.Initial & cmt.Index & "," & cmt.Range.Text & vbCr Next Set doc = Documents.Add doc.Range.Text = s End Sub I tinkered with Selection.Range, however I cannot determine the proper object or property that contains the referenced sentence. I would like to produce output like the follow (if we use the example in picture above): Sentence: Here are more sentences that contain interesting facts - Comment: This is an interesting fact. Sentence: Here are more sentences that contain interesting facts. Here are more sentences that contain interesting facts. - Comment: This is a very interesting fact

    Read the article

  • macro function for printing

    - by seven
    Hi, if for example i have : define PRINT(x) fprintf(stderr, x); and in code i append it : PRINT(("print this")) output is : [print this] if i append it : PRINT(("print %s", "this")) output is : [this] could someone explain me why it receives just the "this" argument and not the whole string ?

    Read the article

  • Are incremental Macro definition possible?

    - by Davorak
    I often find the following type of incremental definition useful: (define (foo) (display "bar")) (foo) ;prints bar (define foo (let ((bar foo)) (lambda () (display "foo") (bar)))) (foo) ;prints foobar How do I preform this type of incremental definition with macros? I could not get let-syntax to provide the same functionality. Currently I use plt scheme, but would like to see answers in different lisp implementations as well.

    Read the article

  • Is incremental Macro definition possible?

    - by Davorak
    I often find the following type of incremental definition useful: (define (foo) (display "bar")) (foo) ;prints bar (define foo (let ((bar foo)) (lambda () (display "foo") (bar)))) (foo) ;prints foobar How do I preform this type of incremental definition with macros? I could not get let-syntax to provide the same functionality. Currently I use plt scheme, but would like to see answers in different lisp implementations as well.

    Read the article

  • C++ boost wave, scoped macro

    - by aaa
    hello. Is it possible to have scoped macros using custom defined macros through boost wave? I know it should a possible with C++0x however I am working with regular C++. If it is possible, can you provide link or reference how to accomplish this? Thanks

    Read the article

  • C++ Macro problem, not replacing all values

    - by JP
    I have the following 2 macros: #define SCOPED_ENUM_HEADER(NAME) struct NAME{ enum _NAME{ #define SCOPED_ENUM_FOOTER(NAME) };}; typedef NAME::_NAME NAMEtype; Only the first instance of NAME get replaced by the passed NAME. What's wrong with it? Is is to be used in such a way: SCOPED_ENUM_HEADER(LOGLEVEL) UNSET, FILE, SCREEN SCOPED_ENUM_FOOTER(LOGLEVEL) Thanks you

    Read the article

  • C++ Macro problem, not remplacing all values

    - by JP
    I have the following 2 macros: #define SCOPED_ENUM_HEADER(NAME) struct NAME{ enum _NAME{ #define SCOPED_ENUM_FOOTER(NAME) };}; typedef NAME::_NAME NAMEtype; Only the first instance of NAME get remplaced by the passed NAME. What's wrong with it? Is is to be used in such a way: SCOPED_ENUM_HEADER(LOGLEVEL) UNSET, FILE, SCREEN SCOPED_ENUM_FOOTER(LOGLEVEL) Thanks you

    Read the article

  • Does the Intel DX79TO motherboard support x8 devices (SAS HBAs) on PCIe x16 slots?

    - by Zac B
    Context: I have an Intel DX79TO motherboard and a Sun SAS3081E-S/LSI 1060E-S HBA card with a PCIe x8 interface. I plug the HBA into my mobo next to my graphics card, and the HBA power lights illuminate, but the BIOS and OSes (tried Linux, ESXi, Win7) don't see the HBA at all. Question: Does the DX79TO motherboard support non-x16/non-GPU devices in its PCIe x16 slots? According to this question, some consumer motherboards don't support this, but I can't figure out whether or not this motherboard/family does. The answer will affect whether I buy a new motherboard or RMA the SAS card, with money attached to each course, so I figured I'd ask here first. What I've Tried: I've read the spec/manuals for the motherboard and the HBA, and I didn't see anything regarding whether or not the x16 slots were back-compatible to lower lane widths/non graphics-card devices, or whether or not the card could run in wider slots than x8. I've tried contacting Intel, but that was over a month ago and I haven't yet heard anything back except an automated "we got your email!" message.

    Read the article

  • from Java to SAS

    - by Giovanni Rossi
    I am a seasoned python,java,...other programmer having a (fairly advanced) mathematical education (so I do understand statistics and data mining, for example) . For various reasons I am thinking to switch to SAS/BI area (I am naming SAS because it might be, for me, a possible way to enter in BI). My question, for whoever might have an experience of both: is it, in BI current state, worth it? I mean, the days of big ideas in BI for business seem to be over (there are the APIs, managers think that they know what you can do with them), and my mathematical background might turn out to be superflous. Also, the big companies now have their data organized, have their BI procedures well established, and trying to analyze it from a different standpoint might not be what they want. Another difference is: while in Java etc. development one codes and codes and codes, I don't know if this is the case for BI; in fact, from what I read on the net, a BI (or OLAP, ...etc) developer, in a big organization, is usually in a state of standby, and does in fact little coding. Any opinions, and in particular strong opinions, will be appreciated.

    Read the article

  • How do I encode Unicode strings using pyodbc to save to a SAS dataset?

    - by Chris B.
    I'm using Python to read and write SAS datasets, using pyodbc and the SAS ODBC drivers. I can load the data perfectly well, but when I save the data, using something like: cursor.execute('insert into dataset.test VALUES (?)', u'testing') ... I get a pyodbc.Error: ('HY004', '[HY004] [Microsoft][ODBC Driver Manager] SQL data type out of range (0) (SQLBindParameter)') error. The problem seems to be the fact I'm passing a unicode string; what do I need to do to handle this?

    Read the article

  • Dell External SAS 5/E HBA and Hyper-V

    - by JohnyD
    I have a Dell R710 running Win2008 R2 + Hyper-V with dual SAS 5/E HBA's. I'm building a Linux VM to install Bacula on and I need to connect it to my Dell PowerVault 124T via the SAS HBA. I've been doing some looking online and I have yet to find a straightforward answer on how to connect a SAS HBA to a VM, let alone a Linux VM. The flavor is Ubuntu 32-bit.

    Read the article

  • C++ MACRO that will execute a block of code and a certain command after that block.

    - by Poni
    void main() { int xyz = 123; // original value { // code block starts xyz++; if(xyz < 1000) xyz = 1; } // code block ends int original_value = xyz; // should be 123 } void main() { int xyz = 123; // original value MACRO_NAME(xyz = 123) // the macro takes the code code that should be executed at the end of the block. { // code block starts xyz++; if(xyz < 1000) xyz = 1; } // code block ends << how to make the macro execute the "xyz = 123" statement? int original_value = xyz; // should be 123 } Only the first main() works. I think the comments explain the issue. It doesn't need to be a macro but to me it just sounds like a classical "macro-needed" case. By the way, there's the BOOST_FOREACH macro/library and I think it does the exact same thing I'm trying to achieve but it's too complex for me to find the essence of what I need. From its introductory manual page, an example: #include <string> #include <iostream> #include <boost/foreach.hpp> int main() { std::string hello( "Hello, world!" ); BOOST_FOREACH( char ch, hello ) { std::cout << ch; } return 0; }

    Read the article

  • PostgreSQL server: 10k RPM SAS or Intel 520 Series SSD drives?

    - by Vlad
    We will be expanding the storage for a PostgreSQL server and one of the things we are considering is using SSDs (Intel 520 Series) instead of rotating discs (10k RPM). Price per GB is comparable and we expect improved performance, however we are concerned about longevity since our database usage pattern is quite write-heavy. We are also concerned about data corruption in case of power failure (due to SSDs write cache not flushing properly). We currently use RAID10 with 4 active HDDs (10k 146GB) and 1 spare configured in the controller. It's a HP DL380 G6 server with P410 Smart Array Controller and BBWC. What makes more sense: upgrading the drives to 300GB 10k RPM or using Intel 520 Series SSDs (240GB)?

    Read the article

  • Cheapest way to connect 20-24 Sata II HDDs in a budget storage server?

    - by Joe Hopfgartner
    I need to assemble a high density storage server for as cheap as possible. It's been a while for me and the last systems I integrated didn't even have Sata yet... During my Research I of course stumbled about Nexsan SATA Beast, the BackBlaze storage Pods as well as some ridiculously overpriced HP Proliant or Dell storage solutions. Finally I choose Norco cases as the way to go. My eye is set on the RPC-4020, which is a 4U 19" Rackmount case with 20 Hot Swap 3.5" SATA/SAS Hdd trays (Backplanes included) and room for two 2.5" OS drives as well as a Slim Line CD-Rom. The backplanes connect with a single SATA port for each drive, so there are 20 internal SATA ports to to be connected. They also have redundant power ports which I think is quite nice. The cheapest price I have found is 290$ + 40$ shipping. In europe the cheapest unfortunately is 370€ (500$) + 40 € shipping... A nice alternative would be the RPC-4224 which has SFF-8087 Mini SAS connectors that bundle 4 SATA trays each. But it doesn't seem to be available in Europe (where i am) anywhere. So here comes my problem: What Mainboard/Controller to choose to connect them for as cheap as possible while still having nice data rates? I have to say that the server is intended as a Storage server with 1gps connectivity and the data transfer will be distributed very evenly across all drives. I also don't require any raid functionality. This is all done at application level, I just need JBOD. So for example if I go for the RPC 4020 Model I need to connect 20 Storage + 1 OS + 1 CDROM Sata ports. I searched a bit and stumbled across this very low priced controller: http://www.intel.com/products/server/raid-controllers/SASWT4I/SASWT4I-overview.htm They sell it for 115 € here and the specs say it can control up to 122 hard discs and has 4 Mini SAS connectors. So I would use 4 Mini SAS 36pin - 4 SATA 7pin cables to connect 4 SATA drives to each port and choose a Mainboard taht has 6 SATA on board (for example this one) and hurray, I can connect my 22 SATA devices for as low as about ~ 220 EUR (cpu, ram, psu, case not counted) Question: WOULD THAT WORK? And if not, why? 2nd Question: If I go for the 4220 or 4224 Model, I have internal Mini SAS connectors. Am I right in assuming that the backplane than acts as a "SAS Expander"? And can I just plug these SAS connectors into any SAS port I can find on my controller / mainboard or are there certain requirements? I know that SATA port multipliers only work with controllers that are ready for that. But isn't this expansion already implemented in the SAS standard? I am sorry that this is a very broad question, but I really spent the last week reading up and it seems to be not so clear! Especially all the controlling hardware specifications! 3rd Question: A lot of hardware specs feature "internal channels" and "internal connectors". The connecors are the physical numbers of places where I can plug a cable in. I got that. But are the "internal channels" always the maximum numbers of physical drives that can be used in the end? Or can I enhance this further by Expanders/Fanouts? 4th and last question: What do you think about the setup so far? Do you know any good alternatives? Maby I am completely going the wrong way and some DAS would be way better? Are there any comparable chassis available in europe? Please feel free to say whatever you think is relevant to the subject!

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • Using macro as an abstraction layer

    - by tehnyit
    I am having a discussion with a colleague about using macro as a thin (extremely) layer of abstraction vs using a function wrapper. The example that I used is Macro way. #define StartOSTimer(period) (microTimerStart(period)) Function wrapper method void StartOSTimer(period) { microTimerStart(period); } Personally, I liked the second method as it allows for future modification, the #include dependencies are also abstracted as well.

    Read the article

< Previous Page | 1 2 3 4 5 6 7 8 9 10 11 12  | Next Page >