Search Results

Search found 1232 results on 50 pages for 'aaron kyle'.

Page 50/50 | < Previous Page | 46 47 48 49 50 

  • Hello Operator, My Switch Is Bored

    - by Paul White
    This is a post for T-SQL Tuesday #43 hosted by my good friend Rob Farley. The topic this month is Plan Operators. I haven’t taken part in T-SQL Tuesday before, but I do like to write about execution plans, so this seemed like a good time to start. This post is in two parts. The first part is primarily an excuse to use a pretty bad play on words in the title of this blog post (if you’re too young to know what a telephone operator or a switchboard is, I hate you). The second part of the post looks at an invisible query plan operator (so to speak). 1. My Switch Is Bored Allow me to present the rare and interesting execution plan operator, Switch: Books Online has this to say about Switch: Following that description, I had a go at producing a Fast Forward Cursor plan that used the TOP operator, but had no luck. That may be due to my lack of skill with cursors, I’m not too sure. The only application of Switch in SQL Server 2012 that I am familiar with requires a local partitioned view: CREATE TABLE dbo.T1 (c1 int NOT NULL CHECK (c1 BETWEEN 00 AND 24)); CREATE TABLE dbo.T2 (c1 int NOT NULL CHECK (c1 BETWEEN 25 AND 49)); CREATE TABLE dbo.T3 (c1 int NOT NULL CHECK (c1 BETWEEN 50 AND 74)); CREATE TABLE dbo.T4 (c1 int NOT NULL CHECK (c1 BETWEEN 75 AND 99)); GO CREATE VIEW V1 AS SELECT c1 FROM dbo.T1 UNION ALL SELECT c1 FROM dbo.T2 UNION ALL SELECT c1 FROM dbo.T3 UNION ALL SELECT c1 FROM dbo.T4; Not only that, but it needs an updatable local partitioned view. We’ll need some primary keys to meet that requirement: ALTER TABLE dbo.T1 ADD CONSTRAINT PK_T1 PRIMARY KEY (c1);   ALTER TABLE dbo.T2 ADD CONSTRAINT PK_T2 PRIMARY KEY (c1);   ALTER TABLE dbo.T3 ADD CONSTRAINT PK_T3 PRIMARY KEY (c1);   ALTER TABLE dbo.T4 ADD CONSTRAINT PK_T4 PRIMARY KEY (c1); We also need an INSERT statement that references the view. Even more specifically, to see a Switch operator, we need to perform a single-row insert (multi-row inserts use a different plan shape): INSERT dbo.V1 (c1) VALUES (1); And now…the execution plan: The Constant Scan manufactures a single row with no columns. The Compute Scalar works out which partition of the view the new value should go in. The Assert checks that the computed partition number is not null (if it is, an error is returned). The Nested Loops Join executes exactly once, with the partition id as an outer reference (correlated parameter). The Switch operator checks the value of the parameter and executes the corresponding input only. If the partition id is 0, the uppermost Clustered Index Insert is executed, adding a row to table T1. If the partition id is 1, the next lower Clustered Index Insert is executed, adding a row to table T2…and so on. In case you were wondering, here’s a query and execution plan for a multi-row insert to the view: INSERT dbo.V1 (c1) VALUES (1), (2); Yuck! An Eager Table Spool and four Filters! I prefer the Switch plan. My guess is that almost all the old strategies that used a Switch operator have been replaced over time, using things like a regular Concatenation Union All combined with Start-Up Filters on its inputs. Other new (relative to the Switch operator) features like table partitioning have specific execution plan support that doesn’t need the Switch operator either. This feels like a bit of a shame, but perhaps it is just nostalgia on my part, it’s hard to know. Please do let me know if you encounter a query that can still use the Switch operator in 2012 – it must be very bored if this is the only possible modern usage! 2. Invisible Plan Operators The second part of this post uses an example based on a question Dave Ballantyne asked using the SQL Sentry Plan Explorer plan upload facility. If you haven’t tried that yet, make sure you’re on the latest version of the (free) Plan Explorer software, and then click the Post to SQLPerformance.com button. That will create a site question with the query plan attached (which can be anonymized if the plan contains sensitive information). Aaron Bertrand and I keep a close eye on questions there, so if you have ever wanted to ask a query plan question of either of us, that’s a good way to do it. The problem The issue I want to talk about revolves around a query issued against a calendar table. The script below creates a simplified version and adds 100 years of per-day information to it: USE tempdb; GO CREATE TABLE dbo.Calendar ( dt date NOT NULL, isWeekday bit NOT NULL, theYear smallint NOT NULL,   CONSTRAINT PK__dbo_Calendar_dt PRIMARY KEY CLUSTERED (dt) ); GO -- Monday is the first day of the week for me SET DATEFIRST 1;   -- Add 100 years of data INSERT dbo.Calendar WITH (TABLOCKX) (dt, isWeekday, theYear) SELECT CA.dt, isWeekday = CASE WHEN DATEPART(WEEKDAY, CA.dt) IN (6, 7) THEN 0 ELSE 1 END, theYear = YEAR(CA.dt) FROM Sandpit.dbo.Numbers AS N CROSS APPLY ( VALUES (DATEADD(DAY, N.n - 1, CONVERT(date, '01 Jan 2000', 113))) ) AS CA (dt) WHERE N.n BETWEEN 1 AND 36525; The following query counts the number of weekend days in 2013: SELECT Days = COUNT_BIG(*) FROM dbo.Calendar AS C WHERE theYear = 2013 AND isWeekday = 0; It returns the correct result (104) using the following execution plan: The query optimizer has managed to estimate the number of rows returned from the table exactly, based purely on the default statistics created separately on the two columns referenced in the query’s WHERE clause. (Well, almost exactly, the unrounded estimate is 104.289 rows.) There is already an invisible operator in this query plan – a Filter operator used to apply the WHERE clause predicates. We can see it by re-running the query with the enormously useful (but undocumented) trace flag 9130 enabled: Now we can see the full picture. The whole table is scanned, returning all 36,525 rows, before the Filter narrows that down to just the 104 we want. Without the trace flag, the Filter is incorporated in the Clustered Index Scan as a residual predicate. It is a little bit more efficient than using a separate operator, but residual predicates are still something you will want to avoid where possible. The estimates are still spot on though: Anyway, looking to improve the performance of this query, Dave added the following filtered index to the Calendar table: CREATE NONCLUSTERED INDEX Weekends ON dbo.Calendar(theYear) WHERE isWeekday = 0; The original query now produces a much more efficient plan: Unfortunately, the estimated number of rows produced by the seek is now wrong (365 instead of 104): What’s going on? The estimate was spot on before we added the index! Explanation You might want to grab a coffee for this bit. Using another trace flag or two (8606 and 8612) we can see that the cardinality estimates were exactly right initially: The highlighted information shows the initial cardinality estimates for the base table (36,525 rows), the result of applying the two relational selects in our WHERE clause (104 rows), and after performing the COUNT_BIG(*) group by aggregate (1 row). All of these are correct, but that was before cost-based optimization got involved :) Cost-based optimization When cost-based optimization starts up, the logical tree above is copied into a structure (the ‘memo’) that has one group per logical operation (roughly speaking). The logical read of the base table (LogOp_Get) ends up in group 7; the two predicates (LogOp_Select) end up in group 8 (with the details of the selections in subgroups 0-6). These two groups still have the correct cardinalities as trace flag 8608 output (initial memo contents) shows: During cost-based optimization, a rule called SelToIdxStrategy runs on group 8. It’s job is to match logical selections to indexable expressions (SARGs). It successfully matches the selections (theYear = 2013, is Weekday = 0) to the filtered index, and writes a new alternative into the memo structure. The new alternative is entered into group 8 as option 1 (option 0 was the original LogOp_Select): The new alternative is to do nothing (PhyOp_NOP = no operation), but to instead follow the new logical instructions listed below the NOP. The LogOp_GetIdx (full read of an index) goes into group 21, and the LogOp_SelectIdx (selection on an index) is placed in group 22, operating on the result of group 21. The definition of the comparison ‘the Year = 2013’ (ScaOp_Comp downwards) was already present in the memo starting at group 2, so no new memo groups are created for that. New Cardinality Estimates The new memo groups require two new cardinality estimates to be derived. First, LogOp_Idx (full read of the index) gets a predicted cardinality of 10,436. This number comes from the filtered index statistics: DBCC SHOW_STATISTICS (Calendar, Weekends) WITH STAT_HEADER; The second new cardinality derivation is for the LogOp_SelectIdx applying the predicate (theYear = 2013). To get a number for this, the cardinality estimator uses statistics for the column ‘theYear’, producing an estimate of 365 rows (there are 365 days in 2013!): DBCC SHOW_STATISTICS (Calendar, theYear) WITH HISTOGRAM; This is where the mistake happens. Cardinality estimation should have used the filtered index statistics here, to get an estimate of 104 rows: DBCC SHOW_STATISTICS (Calendar, Weekends) WITH HISTOGRAM; Unfortunately, the logic has lost sight of the link between the read of the filtered index (LogOp_GetIdx) in group 22, and the selection on that index (LogOp_SelectIdx) that it is deriving a cardinality estimate for, in group 21. The correct cardinality estimate (104 rows) is still present in the memo, attached to group 8, but that group now has a PhyOp_NOP implementation. Skipping over the rest of cost-based optimization (in a belated attempt at brevity) we can see the optimizer’s final output using trace flag 8607: This output shows the (incorrect, but understandable) 365 row estimate for the index range operation, and the correct 104 estimate still attached to its PhyOp_NOP. This tree still has to go through a few post-optimizer rewrites and ‘copy out’ from the memo structure into a tree suitable for the execution engine. One step in this process removes PhyOp_NOP, discarding its 104-row cardinality estimate as it does so. To finish this section on a more positive note, consider what happens if we add an OVER clause to the query aggregate. This isn’t intended to be a ‘fix’ of any sort, I just want to show you that the 104 estimate can survive and be used if later cardinality estimation needs it: SELECT Days = COUNT_BIG(*) OVER () FROM dbo.Calendar AS C WHERE theYear = 2013 AND isWeekday = 0; The estimated execution plan is: Note the 365 estimate at the Index Seek, but the 104 lives again at the Segment! We can imagine the lost predicate ‘isWeekday = 0’ as sitting between the seek and the segment in an invisible Filter operator that drops the estimate from 365 to 104. Even though the NOP group is removed after optimization (so we don’t see it in the execution plan) bear in mind that all cost-based choices were made with the 104-row memo group present, so although things look a bit odd, it shouldn’t affect the optimizer’s plan selection. I should also mention that we can work around the estimation issue by including the index’s filtering columns in the index key: CREATE NONCLUSTERED INDEX Weekends ON dbo.Calendar(theYear, isWeekday) WHERE isWeekday = 0 WITH (DROP_EXISTING = ON); There are some downsides to doing this, including that changes to the isWeekday column may now require Halloween Protection, but that is unlikely to be a big problem for a static calendar table ;)  With the updated index in place, the original query produces an execution plan with the correct cardinality estimation showing at the Index Seek: That’s all for today, remember to let me know about any Switch plans you come across on a modern instance of SQL Server! Finally, here are some other posts of mine that cover other plan operators: Segment and Sequence Project Common Subexpression Spools Why Plan Operators Run Backwards Row Goals and the Top Operator Hash Match Flow Distinct Top N Sort Index Spools and Page Splits Singleton and Range Seeks Bitmaps Hash Join Performance Compute Scalar © 2013 Paul White – All Rights Reserved Twitter: @SQL_Kiwi

    Read the article

  • Book Review: Brownfield Application Development in .NET

    - by DotNetBlues
    I recently finished reading the book Brownfield Application Development in .NET by Kyle Baley and Donald Belcham.  The book is available from Manning.  First off, let me say that I'm a huge fan of Manning as a publisher.  I've found their books to be top-quality, over all.  As a Kindle owner, I also appreciate getting an ebook copy along with the dead tree copy.  I find ebooks to be much more convenient to read, but hard-copies are easier to reference. The book covers, surprisingly enough, working with brownfield applications.  Which is well and good, if that term has meaning to you.  It didn't for me.  Without retreading a chunk of the first chapter, the authors break code bases into three broad categories: greenfield, brownfield, and legacy.  Greenfield is, essentially, new development that hasn't had time to rust and is (hopefully) being approached with some discipline.  Legacy applications are those that are more or less stable and functional, that do not expect to see a lot of work done to them, and are more likely to be replaced than reworked. Brownfield code is the gray (brown?) area between the two and the authors argue, quite effectively, that it is the most likely state for an application to be in.  Brownfield code has, in some way, been allowed to tarnish around the edges and can be difficult to work with.  Although I hadn't realized it, most of the code I've worked on has been brownfield.  Sometimes, there's talk of scrapping and starting over.  Sometimes, the team dismisses increased discipline as ivory tower nonsense.  And, sometimes, I've been the ignorant culprit vexing my future self. The book is broken into two major sections, plus an introduction chapter and an appendix.  The first section covers what the authors refer to as "The Ecosystem" which consists of version control, build and integration, testing, metrics, and defect management.  The second section is on actually writing code for brownfield applications and discusses object-oriented principles, architecture, external dependencies, and, of course, how to deal with these when coming into an existing code base. The ecosystem section is just shy of 140 pages long and brings some real meat to the matter.  The focus on "pain points" immediately sets the tone as problem-solution, rather than academic.  The authors also approach some of the topics from a different angle than some essays I've read on similar topics.  For example, the chapter on automated testing is on just that -- automated testing.  It's all well and good to criticize a project as conflating integration tests with unit tests, but it really doesn't make anyone's life better.  The discussion on testing is more focused on the "right" level of testing for existing projects.  Sometimes, an integration test is the best you can do without gutting a section of functional code.  Even if you can sell other developers and/or management on doing so, it doesn't actually provide benefit to your customers to rewrite code that works.  This isn't to say the authors encourage sloppy coding.  Far from it.  Just that they point out the wisdom of ignoring the sleeping bear until after you deal with the snarling wolf. The other sections take a similarly real-world, workable approach to the pain points they address.  As the section moves from technical solutions like version control and continuous integration (CI) to the softer, process issues of metrics and defect tracking, the authors begin to gently suggest moving toward a zero defect count.  While that really sounds like an unreasonable goal for a lot of ongoing projects, it's quite apparent that the authors have first-hand experience with taming some gruesome projects.  The suggestions are grounded and workable, and the difficulty of some situations is explicitly acknowledged. I have to admit that I started getting bored by the end of the ecosystem section.  No matter how valuable I think a good project manager or business analyst is to a successful ALM, at the end of the day, I'm a gear-head.  Also, while I agreed with a lot of the ecosystem ideas, in theory, I didn't necessarily feel that a lot of the single-developer projects that I'm often involved in really needed that level of rigor.  It's only after reading the sidebars and commentary in the coding section that I had the context for the arguments made in favor of a strong ecosystem supporting the development process.  That isn't to say that I didn't support good product management -- indeed, I've probably pushed too hard, on occasion, for a strong ALM outside of just development.  This book gave me deeper insight into why some corners shouldn't be cut and how damaging certain sins of omission can be. The code section, though, kept me engaged for its entirety.  Many technical books can be used as reference material from day one.  The authors were clear, however, that this book is not one of these.  The first chapter of the section (chapter seven, over all) addresses object oriented (OO) practices.  I've read any number of definitions, discussions, and treatises on OO.  None of the chapter was new to me, but it was a good review, and I'm of the opinion that it's good to review the foundations of what you do, from time to time, so I didn't mind. The remainder of the book is really just about how to apply OOP to existing code -- and, just because all your code exists in classes does not mean that it's object oriented.  That topic has the potential to be extremely condescending, but the authors miraculously managed to never once make me feel like a dolt or that they were wagging their finger at me for my prior sins.  Instead, they continue the "pain points" and problem-solution presentation to give concrete examples of how to apply some pretty academic-sounding ideas.  That's a point worth emphasizing, as my experience with most OO discussions is that they stay in the academic realm.  This book gives some very, very good explanations of why things like the Liskov Substitution Principle exist and why a corporate programmer should even care.  Even if you know, with absolute certainty, that you'll never have to work on an existing code-base, I would recommend this book just for the clarity it provides on OOP. This book goes beyond just theory, or even real-world application.  It presents some methods for fixing problems that any developer can, and probably will, encounter in the wild.  First, the authors address refactoring application layers and internal dependencies.  Then, they take you through those layers from the UI to the data access layer and external dependencies.  Finally, they come full circle to tie it all back to the overall process.  By the time the book is done, you're left with a lot of ideas, but also a reasonable plan to begin to improve an existing project structure. Throughout the book, it's apparent that the authors have their own preferred methodology (TDD and domain-driven design), as well as some preferred tools.  The "Our .NET Toolbox" is something of a neon sign pointing to that latter point.  They do not beat the reader over the head with anything resembling a "One True Way" mentality.  Even for the most emphatic points, the tone is quite congenial and helpful.  With some of the near-theological divides that exist within the tech community, I found this to be one of the more remarkable characteristics of the book.  Although the authors favor tools that might be considered Alt.NET, there is no reason the advice and techniques given couldn't be quite successful in a pure Microsoft shop with Team Foundation Server.  For that matter, even though the book specifically addresses .NET, it could be applied to a Java and Oracle shop, as well.

    Read the article

  • What would cause ANY .NET application to crash immediately... except a project I create and Debug in

    - by blak3r
    My software recently got deployed to a customer who said that the application was crashing immediately after it started. After some initial debugging, the customer provided me remote access to one of the computers which was unable to run the application. I found that the crash wasn't specific to my application. Any application which depended on the .NET framework crashed immediately. Conveniently, Visual Studio 2008 was installed so I created a quick hello world application on it and clicked Debug. The application worked fine. But, then when I tried to execute the generated binaries in the /bin/Debug/HelloWorld.exe directory outside of visual studio it crashed. List of things i've tried (UPDATED): I checked that "Everyone" has Read&Execute permissions for c:\Windows. To test that the problem was with the .NET Framework (and not my application), I attempted to download Paint .NET on to the computers. The setup frontend crashed in the same manner. Performed a repair of the .NET framework as outlined in http://support.microsoft.com/kb/908077 (Boy was this fun and time consuming). No luck. Installed .NET 3.5 SP1 (before it just had .NET 3.5) Note: my application targets 2.0 so I did this more as a long shot... but i learned in the process that .NET 3.5 SP1 also updates the underlying frameworks. Ran Aaron Stebner's .NET Setup Verification Tool. This tool indicated that .NET was successfully installed. (I forget if i checked all the versions but at least 2.0 worked). Tested some mini hello world applications which were targeted for .NET 2.0 and .NET 3.5 and both crashed in the same way. Tried launching .NET apps via windbg cmd line. Doing this did allow me invoke my simple hello world applications. So, simple .NET hello world works when invoked by windbg or by launching via debug in visual studio... but doesn't if i try to execute it standalone. I created a dump file using WinDbg. It wasn't all that revealing to me. FAULTING_IP: mscorwks!PEImage::GetEntryPointToken+21 79f4ff9d f6401010 test byte ptr [eax+10h],10h EXCEPTION_RECORD: 0012f710 -- (.exr 0x12f710) ExceptionAddress: 79f4ff9d (mscorwks!PEImage::GetEntryPointToken+0x00000021) ExceptionCode: c0000005 (Access violation) ExceptionFlags: 00000000 NumberParameters: 2 Parameter[0]: 00000000 Parameter[1]: 00000010 Attempt to read from address 00000010 FAULTING_THREAD: 00000b44 PROCESS_NAME: MyProcess.exe ERROR_CODE: (NTSTATUS) 0x80000003 - {EXCEPTION} Breakpoint A breakpoint has been reached. EXCEPTION_CODE: (HRESULT) 0x80000003 (2147483651) - One or more arguments are invalid DETOURED_IMAGE: 1 NTGLOBALFLAG: 0 APPLICATION_VERIFIER_FLAGS: 0 MANAGED_STACK: !dumpstack -EE OS Thread Id: 0xb44 (0) Current frame: ChildEBP RetAddr Caller,Callee EXCEPTION_OBJECT: !pe cb10b4 Exception object: 00cb10b4 Exception type: System.ExecutionEngineException Message: <none> InnerException: <none> StackTrace (generated): <none> StackTraceString: <none> HResult: 80131506 MANAGED_OBJECT_NAME: System.ExecutionEngineException CONTEXT: 0012f72c -- (.cxr 0x12f72c) eax=00000000 ebx=00000000 ecx=00000000 edx=0000000e esi=001a1490 edi=00000001 eip=79f4ff9d esp=0012f9f8 ebp=0012fa1c iopl=0 nv up ei pl zr na pe nc cs=001b ss=0023 ds=0023 es=0023 fs=003b gs=0000 efl=00010246 mscorwks!PEImage::GetEntryPointToken+0x21: 79f4ff9d f6401010 test byte ptr [eax+10h],10h ds:0023:00000010=?? Resetting default scope READ_ADDRESS: 00000010 FOLLOWUP_IP: mscorwks!PEImage::GetEntryPointToken+21 79f4ff9d f6401010 test byte ptr [eax+10h],10h BUGCHECK_STR: APPLICATION_FAULT_NULL_CLASS_PTR_DEREFERENCE_SHUTDOWN PRIMARY_PROBLEM_CLASS: NULL_CLASS_PTR_DEREFERENCE_SHUTDOWN DEFAULT_BUCKET_ID: NULL_CLASS_PTR_DEREFERENCE_SHUTDOWN LAST_CONTROL_TRANSFER: from 79ef02b5 to 79f4ff9d STACK_TEXT: 79f4ff9d mscorwks!PEImage::GetEntryPointToken+0x21 79ef02b5 mscorwks!PEFile::GetEntryPointToken+0xa0 79eefeaf mscorwks!SystemDomain::ExecuteMainMethod+0xd4 79fb9793 mscorwks!ExecuteEXE+0x59 79fb96df mscorwks!_CorExeMain+0x15c 7900b1b3 mscoree!_CorExeMain+0x2c 7c817077 kernel32!BaseProcessStart+0x23 SYMBOL_STACK_INDEX: 0 SYMBOL_NAME: mscorwks!PEImage::GetEntryPointToken+21 FOLLOWUP_NAME: MachineOwner MODULE_NAME: mscorwks IMAGE_NAME: mscorwks.dll DEBUG_FLR_IMAGE_TIMESTAMP: 471ef729 STACK_COMMAND: .cxr 0012F72C ; kb ; dds 12f9f8 ; kb FAILURE_BUCKET_ID: NULL_CLASS_PTR_DEREFERENCE_SHUTDOWN_80000003_mscorwks.dll!PEImage::GetEntryPointToken BUCKET_ID: APPLICATION_FAULT_NULL_CLASS_PTR_DEREFERENCE_SHUTDOWN_DETOURED_mscorwks!PEImage::GetEntryPointToken+21 WATSON_STAGEONE_URL: http://watson.microsoft.com/StageOne/MyProcess_exe/2_4_4_39/4a8a192c/unknown/0_0_0_0/bbbbbbb4/80000003/00000000.htm?Retriage=1 Followup: MachineOwner Edit 1:The event log details for this error say it's a .NET Runtime version 2.0.50727.3053 - Fatal Execution Engine Error (7A097706)(80131506). Edit 2 (10-7-09): This issue is still active. Edit 3 (3-29-10): This update is to let everyone know that I never did successfully solve the problem. The customer who's machine this was on lost interest in solving it and just reimaged the machine :(. Thanks for all the contributions though.

    Read the article

  • The maximum message size quota for incoming messages (65536) has been exceeded.

    - by DaleyKD
    My WCF Service has an OperationContract that accepts, as a parameter, an array of objects. This can potentially be quite large. After looking for fixes for Bad Request: 400, I found the real reason: the maximum message size. I know this question has been asked before in MANY places. I've tried what everyone says: "Increase the sizes in the client and server config files." I have. It still doesn't work. My Service's web.config: <system.serviceModel> <services> <service name="myService"> <endpoint name="myEndpoint" address="" binding="basicHttpBinding" bindingConfiguration="myBinding" contract="Meisel.WCF.PDFDocs.IPDFDocsService" /> </service> </services> <bindings> <basicHttpBinding> <binding name="myBinding" closeTimeout="00:11:00" openTimeout="00:11:00" receiveTimeout="00:15:00" sendTimeout="00:15:00" maxBufferSize="2147483647" maxReceivedMessageSize="2147483647" maxBufferPoolSize="2147483647" transferMode="Buffered" allowCookies="false" bypassProxyOnLocal="false" hostNameComparisonMode="StrongWildcard" messageEncoding="Text" textEncoding="utf-8" useDefaultWebProxy="true"> <readerQuotas maxDepth="2147483647" maxStringContentLength="2147483647" maxArrayLength="2147483647" maxBytesPerRead="2147483647" maxNameTableCharCount="2147483647" /> <security mode="None" /> </binding> </basicHttpBinding> </bindings> <behaviors> <serviceBehaviors> <behavior> <serviceMetadata httpGetEnabled="true" /> <serviceDebug includeExceptionDetailInFaults="true" /> <dataContractSerializer maxItemsInObjectGraph="2147483647" /> </behavior> </serviceBehaviors> </behaviors> <serviceHostingEnvironment multipleSiteBindingsEnabled="true" /> </system.serviceModel> My Client's app.config: <system.serviceModel> <bindings> <basicHttpBinding> <binding name="BasicHttpBinding_IPDFDocsService" closeTimeout="00:11:00" openTimeout="00:11:00" receiveTimeout="00:10:00" sendTimeout="00:11:00" allowCookies="false" bypassProxyOnLocal="false" hostNameComparisonMode="StrongWildcard" maxBufferSize="2147483647" maxBufferPoolSize="2147483647" maxReceivedMessageSize="2147483647" messageEncoding="Text" textEncoding="utf-8" transferMode="Buffered" useDefaultWebProxy="true"> <readerQuotas maxDepth="32" maxStringContentLength="2147483647" maxArrayLength="2147483647" maxBytesPerRead="2147483647" maxNameTableCharCount="2147483647" /> <security mode="None"> <transport clientCredentialType="None" proxyCredentialType="None" realm="" /> <message clientCredentialType="UserName" algorithmSuite="Default" /> </security> </binding> </basicHttpBinding> </bindings> <client> <endpoint address="http://localhost:8451/PDFDocsService.svc" behaviorConfiguration="MoreItemsInObjectGraph" binding="basicHttpBinding" bindingConfiguration="BasicHttpBinding_IPDFDocsService" contract="PDFDocsService.IPDFDocsService" name="BasicHttpBinding_IPDFDocsService" /> </client> <behaviors> <endpointBehaviors> <behavior name="MoreItemsInObjectGraph"> <dataContractSerializer maxItemsInObjectGraph="2147483647" /> </behavior> </endpointBehaviors> </behaviors> </system.serviceModel> What can I possibly be missing or doing wrong? It's as though the service is ignoring what I typed in the maxReceivedBufferSize. Thanks in advance, Kyle UPDATE Here are two other StackOverflow questions where they never received an answer, either: http://stackoverflow.com/questions/2880623/maxreceivedmessagesize-adjusted-but-still-getting-the-quotaexceedexception-with http://stackoverflow.com/questions/2569715/wcf-maxreceivedmessagesize-property-not-taking

    Read the article

  • Help with Design for Vacation Tracking System (C#/.NET/Access/WebServices/SOA/Excel) [closed]

    - by Aaronaught
    I have been tasked with developing a system for tracking our company's paid time-off (vacation, sick days, etc.) At the moment we are using an Excel spreadsheet on a shared network drive, and it works pretty well, but we are concerned that we won't be able to "trust" employees forever and sometimes we run into locking issues when two people try to open the spreadsheet at once. So we are trying to build something a little more robust. I would like some input on this design in terms of maintainability, scalability, extensibility, etc. It's a pretty simple workflow we need to represent right now: I started with a basic MS Access schema like this: Employees (EmpID int, EmpName varchar(50), AllowedDays int) Vacations (VacationID int, EmpID int, BeginDate datetime, EndDate datetime) But we don't want to spend a lot of time building a schema and database like this and have to change it later, so I think I am going to go with something that will be easier to expand through configuration. Right now the vacation table has this schema: Vacations (VacationID int, PropName varchar(50), PropValue varchar(50)) And the table will be populated with data like this: VacationID | PropName | PropValue -----------+--------------+------------------ 1 | EmpID | 4 1 | EmpName | James Jones 1 | Reason | Vacation 1 | BeginDate | 2/24/2010 1 | EndDate | 2/30/2010 1 | Destination | Spectate Swamp 2 | ... | ... I think this is a pretty good, extensible design, we can easily add new properties to the vacation like the destination or maybe approval status, etc. I wasn't too sure how to go about managing the database of valid properties, I thought of putting them in a separate PropNames table but it gets complicated to manage all the different data types and people say that you shouldn't put CLR type names into a SQL database, so I decided to use XML instead, here is the schema: <VacationProperties> <PropertyNames>EmpID,EmpName,Reason,BeginDate,EndDate,Destination</PropertyNames> <PropertyTypes>System.Int32,System.String,System.String,System.DateTime,System.DateTime,System.String</PropertyTypes> <PropertiesRequired>true,true,false,true,true,false</PropertiesRequired> </VacationProperties> I might need more fields than that, I'm not completely sure. I'm parsing the XML like this (would like some feedback on the parsing code): string xml = File.ReadAllText("properties.xml"); Match m = Regex.Match(xml, "<(PropertyNames)>(.*?)</PropertyNames>"; string[] pn = m.Value.Split(','); // do the same for PropertyTypes, PropertiesRequired Then I use the following code to persist configuration changes to the database: string sql = "DROP TABLE VacationProperties"; sql = sql + " CREATE TABLE VacationProperties "; sql = sql + "(PropertyName varchar(100), PropertyType varchar(100) "; sql = sql + "IsRequired varchar(100))"; for (int i = 0; i < pn.Length; i++) { sql = sql + " INSERT VacationProperties VALUES (" + pn[i] + "," + pt[i] + "," + pv[i] + ")"; } // GlobalConnection is a singleton new SqlCommand(sql, GlobalConnection.Instance).ExecuteReader(); So far so good, but after a few days of this I then realized that a lot of this was just a more specific kind of a generic workflow which could be further abstracted, and instead of writing all of this boilerplate plumbing code I could just come up with a workflow and plug it into a workflow engine like Windows Workflow Foundation and have the users configure it: In order to support routing these configurations throw the workflow system, it seemed natural to implement generic XML Web Services for this instead of just using an XML file as above. I've used this code to implement the Web Services: public class VacationConfigurationService : WebService { [WebMethod] public void UpdateConfiguration(string xml) { // Above code goes here } } Which was pretty easy, although I'm still working on a way to validate that XML against some kind of schema as there's no error-checking yet. I also created a few different services for other operations like VacationSubmissionService, VacationReportService, VacationDataService, VacationAuthenticationService, etc. The whole Service Oriented Architecture looks like this: And because the workflow itself might change, I have been working on a way to integrate the WF workflow system with MS Visio, which everybody at the office already knows how to use so they could make changes pretty easily. We have a diagram that looks like the following (it's kind of hard to read but the main items are Activities, Authenticators, Validators, Transformers, Processors, and Data Connections, they're all analogous to the services in the SOA diagram above). The requirements for this system are: (Note - I don't control these, they were given to me by management) Main workflow must interface with Excel spreadsheet, probably through VBA macros (to ease the transition to the new system) Alerts should integrate with MS Outlook, Lotus Notes, and SMS (text messages). We also want to interface it with the company Voice Mail system but that is not a "hard" requirement. Performance requirements: Must handle 250,000 Transactions Per Second Should be able to handle up to 20,000 employees (right now we have 3) 99.99% uptime ("four nines") expected Must be secure against outside hacking, but users cannot be required to enter a username/password. Platforms: Must support Windows XP/Vista/7, Linux, iPhone, Blackberry, DOS 2.0, VAX, IRIX, PDP-11, Apple IIc. Time to complete: 6 to 8 weeks. My questions are: Is this a good design for the system so far? Am I using all of the recommended best practices for these technologies? How do I integrate the Visio diagram above with the Windows Workflow Foundation to call the ConfigurationService and persist workflow changes? Am I missing any important components? Will this be extensible enough to support any scenario via end-user configuration? Will the system scale to the above performance requirements? Will we need any expensive hardware to run it? Are there any "gotchas" I should know about with respect to cross-platform compatibility? For example would it be difficult to convert this to an iPhone app? How long would you expect this to take? (We've dedicated 1 week for testing so I'm thinking maybe 5 weeks?) Many thanks for your advices, Aaron

    Read the article

  • applet does not load

    - by jcp
    We have a legacy program that was ported from Java 1.3 to Java 1.5. This application involves applets which worked fine before. After porting however, the applet would not load. However there are no errors or exceptions. The app would just try to load it forever. We tried to run it with Java 1.6 and poof! No problems whatsoever. Isn't Java 6 backwards compatible? So how come it would run in that version and not in 1.5? ==== Java Console log for Java 1.5.0_19 basic: Registered modality listener basic: Registered modality listener basic: Registered modality listener liveconnect: Invoking JS method: document liveconnect: Invoking JS method: document liveconnect: Invoking JS method: document liveconnect: Invoking JS method: URL liveconnect: Invoking JS method: URL liveconnect: Invoking JS method: URL basic: Referencing classloader: sun.plugin.ClassLoaderInfo@bb7759, refcount=1 basic: Referencing classloader: sun.plugin.ClassLoaderInfo@bb7759, refcount=2 basic: Referencing classloader: sun.plugin.ClassLoaderInfo@bb7759, refcount=3 basic: Added progress listener: sun.plugin.util.GrayBoxPainter@b0bad7 basic: Loading applet ... basic: Initializing applet ... basic: Starting applet ... basic: Added progress listener: sun.plugin.util.GrayBoxPainter@ba9340 basic: Added progress listener: sun.plugin.util.GrayBoxPainter@1198891 basic: Loading applet ... basic: Initializing applet ... basic: Starting applet ... basic: Loading applet ... basic: Initializing applet ... basic: Starting applet ... basic: Referencing classloader: sun.plugin.ClassLoaderInfo@bb7759, refcount=4 basic: Releasing classloader: sun.plugin.ClassLoaderInfo@bb7759, refcount=3 basic: Referencing classloader: sun.plugin.ClassLoaderInfo@bb7759, refcount=4 basic: Releasing classloader: sun.plugin.ClassLoaderInfo@bb7759, refcount=3 basic: Referencing classloader: sun.plugin.ClassLoaderInfo@bb7759, refcount=4 basic: Releasing classloader: sun.plugin.ClassLoaderInfo@bb7759, refcount=3 network: Connecting <something>.jar with proxy=HTTP @ proxy/<ip address> basic: Loading <something>.jar from cache basic: No certificate info, this is unsigned JAR file. Left START init() Left END init() Right START init() Control start() Waiting for Left Panel to load... Right START start() network: Connecting socket://<ip address>:14444 with proxy=DIRECT Control start() Waiting for Left Panel to load... Control start() Waiting for Left Panel to load... Control start() Waiting for Left Panel to load... my HostName : <ip address> Thread-19 Check : Thread-19 Check : Monitor : run : start Thread-20 Monitor : Monitor: run() start Control start() Waiting for Left Panel to load... Control start() Waiting for Left Panel to load... Control start() Waiting for Left Panel to load... Control start() Waiting for Left Panel to load... Control start() Waiting for Left Panel to load... Control start() Waiting for Left Panel to load... the last message goes on forever... and now with the working version: ==== Java Console log for Java 1.6.0_15 basic: Added progress listener: sun.plugin.util.GrayBoxPainter$GrayBoxProgressListener@1b000e7 basic: Added progress listener: sun.plugin.util.GrayBoxPainter$GrayBoxProgressListener@12611a7 basic: Added progress listener: sun.plugin.util.GrayBoxPainter$GrayBoxProgressListener@1807ca8 network: CleanupThread used 6 us network: CleanupThread used 5 us network: CleanupThread used 6 us cache: Skip blacklist check as cached value is ok. network: Cache entry found [url: <something>.jar, version: null] network: Connecting <something>.jar with proxy=HTTP @ proxy/<ip address> network: ResponseCode for <something>.jar : 304 network: Encoding for <something>.jar : null network: Disconnect connection to <something>.jar Reading certificates from 11 <something>.jar | <something>.idx network: No certificate info for unsigned JAR file: <something>.jar basic: Applet loaded. basic: Applet loaded. basic: Applet resized and added to parent container basic: Applet resized and added to parent container basic: PERF: AppletExecutionRunnable - applet.init() BEGIN ; jvmLaunch dt 330275 us, pluginInit dt 27768955 us, TotalTime: 28099230 us Right START init() basic: PERF: AppletExecutionRunnable - applet.init() BEGIN ; jvmLaunch dt 330275 us, pluginInit dt 27770563 us, TotalTime: 28100838 us Left START init() basic: Applet loaded. basic: Applet resized and added to parent container basic: PERF: AppletExecutionRunnable - applet.init() BEGIN ; jvmLaunch dt 330275 us, pluginInit dt 27779332 us, TotalTime: 28109607 us Left END init() basic: Applet initialized basic: Removed progress listener: sun.plugin.util.GrayBoxPainter$GrayBoxProgressListener@12611a7 basic: Applet made visible And that's it. Still haven't figured out why it works with java6 and not java5. @valli: the object tag was used, not applet @thorbjorn: i tried that already... it just keeps saying loading applet... @aaron: how can i know what exception it is, if there really is one? and yes we have considered that its a java bug but i still havent found what that bug is. i have to submit a report tomorrow and i've scoured the net but came up with nothing as of yet... @all: thank you for your replies

    Read the article

  • PC powers off at random times

    - by Timo Huovinen
    Short Version After experiencing some problems with Mobo batteries my PC started to power off at random times, the power off is instant and sudden and does not restart afterwards, need help figuring out the cause. Facts: Powers off when PC is playing games Powers off when PC is idle Powers off when PC is in safe mode Powers off when PC is in BIOS Powers off when PC is booted through a Windows installation USB Replaced the motherboard battery several times Replaced the 650W PSU with a 750W PSU Replaced the RAM Swapped the RAM between slots Re-applied thermal paste to the CPU Checked if the motherboard touches the case Nothing is overclocked PC Specs PC specs: OS: Windows 7 Ultimate SP1 RAM: klingston 1333MHz 4GB stick CPU: AMD Phenom II x4 955 Mobo: Gigabyte 88GMA-UD2H rev 2.2 Motherboard battery: CR2032 3v HDD: 500GB Seagate ST3500418AS ATA Device Graphics: ATI/AMD Radeon HD 6870 Very Long version Around 10 months ago I built a brand new gaming PC. Around 6 months ago it's time setting in windows started resetting to the year 2010. I swapped the Motherboard battery for a new one of the exact same size and shape and voltage, and the problems disappeared...for around 2 weeks. Then the same problem happened again, time gets reset, I swapped the battery again, and the problem was gone for good and everything was great for about 3 months.. then another problem started happening, the PC started to power off suddenly and without warning at completely random times, sometimes the PC works for and hour, sometimes 5 minutes. So I read on the forums that it might be either the PSU or the motherboard Battery or RAM or HDD or the Graphics card or the CPU or the motherboard or the drivers or a Virus or Grounding issues, or something short circuiting, basically it can be anything... I spent some days researching, and decided to remove the possibility of a virus. I reset the CMOS, cleared all BIOS settings and reinstalled windows 7 after a full format of the HDD, but the random power off kept happening. I then disabled the restart on error option in windows and looked at the event log for error events, but they did not help me figure out the problem. Network list service depends on network location awareness the dependency group failed to start Source Kernel Power Event 41 Task Category 63 Source Disk Event ID 11 Task Category None The driver detected a controller error on device disk I took apart the PC, every little piece, re-applied some expensive thermal paste to the CPU, and double checked that none of the pieces are touching the PC case. The problem was gone, the PC no longer powered off randomly I re-attached the graphics card and all was good for 4 months... then the power off problem appeared again, but was happening at high intervals, the PC would shutdown once in 2 days on average, at random points in time, sometimes when it's idle all day long, sometimes when it's running CRYSIS 2. I checked the CPU temperature, because I know that AMD CPU's have a built in protection mechanism that switches off the PC if the CPU gets too hot, and the Temp was 50C system temp, and 45C CPU after running the PC all day long (I did not do tests to see if there are any temperature spikes, don't know how to do them) Originally the PSU that powered the PC was 650Watts and had one 4 pin cable to power the CPU, I replaced it with a new 750Watts PSU which has two 4 pin cables for the CPU, but the problem remained. I removed the graphics card and let the motherboard use the built in one, but the PC kept suddenly powering off at random times. I took apart the PC completely again, and re-applied thermal paste to the CPU, added lots of insulation, and checked for any type of short-circuit possibility again and again, but the problem remained. The problem was like that for some months. I replaced the Battery a couple of times over the time, changed lots of options in windows, and tried everything I could, but it kept powering off, so I stopped using the PC as much as I used to, just living with the random power offs from time to time, until a couple of days ago, when the power off happens almost immediately after powering on the PC. I replaced the RAM with a brand new one, but that did not help. Took apart the PC again, checked for anything anywhere that might cause it, found some small scratches on the very edge of the motherboard to the left of the PCI express x16 slot. This might cause the problem, I thought, but the scratch looks very superficial, not deep at all, and if the scratch did harm the motherboard, wouldn't it cause it to not start at all? And why did it start to power off a while ago, and then suddenly stop powering off? The scratches could not have vanished??? did chkdsk \d but it powered off when it was at 75% I removed the hard disks, the graphics card, while I fiddled with the BIOS settings, and suddenly the PC shut down while I was looking at the BIOS version. This makes me realize, it is not caused by: HDD, Windows, Drivers or the Graphics card I cleared the CMOS again, updated the BIOS from F5 to F6f beta, but that did not help, it might even seem that the PC powers off even sooner. The shutdown even happened to me while I booted through a windows 7 installation USB and was in the repair console. I removed one of the cables powering the CPU, now only one 4pin cable powers it, and it worked for 30mins after doing that, which makes me think that it's the CPU overheating, and because it gets less power, it overheats slower? The things that I am still considering: CPU overheating (does not seem to overheat, maybe false readings?) Motherboard short circuiting (faulty motherboard?) I desperately need some advice in what is faulty, is it a faulty Motherboard or an overheating CPU? or maybe something else? I have been breaking my head over this problem over a span of 6 months. I'm not sure if this is a good place to ask this question, if it is not, then tell me where I can get some experienced help. More info I have also discovered a mysterious piece that seems to have fallen out of the motherboard i119.photobucket.com/albums/o126/yurikolovsky/strangepiece.jpg What is it? Looks like each time that it powers off the datetime gets reset I also found another forum post tomshardware.co.uk/forum/… except I don't have Integrated PeripheralsUSB Keyboard Function option in BIOS :S Comments summary (asked by Random moderator) Q. tell me, if the computer restarts, is it immediately? Does it take a second and then restarts? Do you see (BSOD) or hear (PSU, short circuit) any suspicious when it happens? After reading trough it, it remains the mainboard that is faulty. – JohannesM A. Immediate power off, all the fans stop instantly, all the light turn off instantly, no sound or anything, and it remains off until I turn it back on. Thanks for the feedback, faulty motherboard is what I fear. Q. Try stress-testing the system with Prime95 and see if errors or shutdowns occur when the CPU is under full load. – speakr A. Prime95 heat stress test peaked CPU heat at 60C after 5mins, it powered off after 30mins of testing in the middle of the test with no errors, Prime95 Heat test or the stress-testing with low RAM usage (small or in-place FFTs) do not report errors while testing for 10-60 mins. The power off does not seem like it is affected by Prime95 at all Makes me wonder if it's a CPU or Motherboard issue at all. Q. I had similar random/intermittent problems with my old board. It gave one of a few different symptoms: keyboard and/or mouse would die and/or the RAM wouldn't work and/or it would shut down. It was in bad shape. One problems was that my old PSU had literally burned the connector on it (browned around the pins), another was that a broken lead inside the layers of the PCB would work sometimes if it happened to be hot or if I bent the board—by jamming a hunk of wood behind it. I managed to keep the board alive for several years, but eventually nothing I did would make it work correctly anymore. – Synetech A. I will try that as the last resort, ok? ;) Q. Have you tried a different power cord, surge protector, outlet (on a different circuit). It's worth a shot just to ensure it's not subpar wiring or a week circuit (dips in power may cause shutdown if the PSU can't pull enough juice from the wall). – Kyle A. yes, I attached the PC to an entirely different outlet on a different circuit and the problem persists. After connecting it to a different outlet after starting the PC it gave me 3 long beeps and 1 short one, then the PC immediately proceeded to boot up normally. Q. Re-check your mainboard manual and all PSU connections to your mainboard to be sure that nothing is missing (e.g. 12V ATX 4-pin/6-pin connector). If you can provoke shutdowns with Prime95, then consider buying new hardware -- a stable system should run Prime95 for 24h without any errors. Prime95 mentions errors in the log when they occur and gives a summary after the stress test was stopped manually (e.g. "0 errors, 0 warnings", if all is fine) – speakr A. Re-checked, there are no more PSU connectors that I can physically connect, except the one ATX 4-pin (there are 2 that power the CPU) that I disconnected on purpose, I have reconnected it but the problem persists. Q. With one PC I had a short curcuit. The power button on the front plate had its cables soldered, but not isolated, and the contacts were very close to the metal case. A heavier touch was enough to cause a shutdown. The PC's vibration could be enough – ott-- A. yes, it seems to switch off with even the lightest touch, I switched on the PC, then pulled out the front panel power cable that connects to the motherboard so the power button does not work anymore, after 5 mins of working like that, with the power button completely disconnected, just sitting idle, the PC powered off again, I don't think it's the power button. Q. I wonder if you dare to operate components without the case, that is remove motherboard, power, disk ( just put the motherboard on a wooden desk). Don't bend the adapters when running like that. – ott-- A. yes, I do dare to do that, but only tomorrow, too tired/late right now.

    Read the article

< Previous Page | 46 47 48 49 50