Search Results

Search found 44026 results on 1762 pages for 'raid question'.

Page 50/1762 | < Previous Page | 46 47 48 49 50 51 52 53 54 55 56 57  | Next Page >

  • Expendable, Redundant, Easily recoverable

    - by MeIr
    I am desperate at this point, I have been looking for "Big storage" solution for a while on my own and I can't find anything that would suite my needs. But now push came to shove. Current situation: I have about 6TB data storage (already full) - Drobo. Yesterday Drobo died on me and it put me into bad situation - I can't recover my data without buying another Drobo. From extensive research online I realized that Drobo is not the safest bet and by now it seems very poor choice. I ordered new Drobo to try to get my data back, however I don't want to be in the same situation later and continuing using Drobo promises this event to re-occur. What I am looking for: 1) Inexpensive setup. 2) Dynamically extendable - add more drives and/or replace a drive with bigger capacity. 3) Redundant - setup against 1-3 drive failure, will depend on total number of drives. For the sake of argument let's assume for every 4 drives one should be able to fail without data loss. 4) Easy data recovery - let's say unforeseen happens, I would like to be able to recover information without buying new tools or replacements - example: new Drobo. 5) Should be USB or Network Attach Storage 6) No demand on speed. Doesn't have to be fast, I am not doing video editing on the setup. However if option exists, would be nice to have a decent speed. After thoughts: I reviewed few options and FreeNAS looks nice, but it doesn't have #2 - Dynamic extendability. There are work around with Pools but it seems a bit complicated and unnecessary. More over it seems like data safety is a big question - saw some horror stories. Please advise on what options I have and what seems like an optimal solution (if any). I don't care if it has to be Windows or Linux box or any other OS and/or software that has to run on top, but simple solution is more attractive. Thank you! P.S: Feel free to ignore "After thoughts".

    Read the article

  • debugging scaffolding contingent upon degbugging boolean (java)

    - by David
    Recently i've found myself writing a lot of methods with what i can only think to call debugging scaffolding. Here's an example: public static void printArray (String[] array, boolean bug) { for (int i = 0; i<array.lenght; i++) { if (bug) System.out.print (i) ; //this line is what i'm calling the debugging scaffolding i guess. System.out.println(array[i]) ; } } in this method if i set bug to true, wherever its being called from maybe by some kind of user imput, then i get the special debugging text to let me know what index the string being printed as at just in case i needed to know for the sake of my debugging (pretend a state of affairs exists where its helpful). All of my questions more or less boil down to the question: is this a good idea? but with a tad bit more objectivity: Is this an effective way to test my methods and debug them? i mean effective in terms of efficiency and not messing up my code. Is it acceptable to leave the if (bug) stuff ; code in place after i've got my method up and working? (if a definition of "acceptability" is needed to make this question objective then use "is not a matter of programing controversy such as ommiting brackets in an if(boolean) with only one line after it, though if you've got something better go ahead and use your definition i won't mind) Is there a more effective way to accomplish the gole of making debugging easier than what i'm doing? Anything you know i mean to ask but that i have forgotten too (as much information as makes sense is appreciated).

    Read the article

  • special debugging lines (java)

    - by David
    Recently i've found myself writing a lot of methods with what i can only think to call debugging scaffolding. Here's an example: public static void printArray (String[] array, boolean bug) { for (int i = 0; i<array.lenght; i++) { if (bug) System.out.print (i) ; //this line is what i'm calling the debugging scaffolding i guess. System.out.println(array[i]) ; } } in this method if i set bug to true, wherever its being called from maybe by some kind of user imput, then i get the special debugging text to let me know what index the string being printed as at just in case i needed to know for the sake of my debugging (pretend a state of affairs exists where its helpful). All of my questions more or less boil down to the question: is this a good idea? but with a tad bit more objectivity: Is this an effective way to test my methods and debug them? i mean effective in terms of efficiency and not messing up my code. Is it acceptable to leave the if (bug) stuff ; code in place after i've got my method up and working? (if a definition of "acceptability" is needed to make this question objective then use "is not a matter of programing controversy such as ommiting brackets in an if(boolean) with only one line after it, though if you've got something better go ahead and use your definition i won't mind) Is there a more effective way to accomplish the gole of making debugging easier than what i'm doing? Anything you know i mean to ask but that i have forgotten too (as much information as makes sense is appreciated).

    Read the article

  • Language for non-programmers to start learning programming

    - by zarawesome
    A non-programmer friend will be starting the Computer Science college course in a few months. I'd like her to try her hand at some programming before she starts her studies (the course itself expects one to know C, but it's an horrible language to learn to program at). What language would be the best to do so? Related question: Best ways to teach a beginner to program?

    Read the article

  • Android Multiple Handlers Design Question

    - by Soumya Simanta
    This question is related to an existing question I asked. I though I'll ask a new question instead of replying back to the other question. Cannot "comment" on my previous question because of a word limit. Marc wrote - I've more than one Handlers in an Activity." Why? If you do not want a complicated handleMessage() method, then use post() (on Handler or View) to break the logic up into individual Runnables. Multiple Handlers makes me nervous. I'm new to Android. Is having multiple handlers in a single activity a bad design ? I'm new to Android. My question is - is having multiple handlers in a single activity a bad design ? Here is the sketch of my current implementation. I've a mapActivity that creates a data thread (a UDP socket that listens for data). My first handler is responsible for sending data from the data thread to the activity. On the map I've a bunch of "dynamic" markers that are refreshed frequently. Some of these markers are video markers i.e., if the user clicks a video marker, I add a ViewView that extends a android.opengl.GLSurfaceView to my map activity and display video on this new vide. I use my second handler to send information about the marker that the user tapped on ItemizedOverlay onTap(int index) method. The user can close the video view by tapping on the video view. I use my third handler for this. I would appreciate if people can tell me what's wrong with this approach and suggest better ways to implement this. Thanks.

    Read the article

  • HP SmartArray P400 has slow read and write speed

    - by Tadas D.
    I have desktop in which I installed HP SmartArray P400 controller with two HP DF0146B8052 hard drives. I made RAID0 logical volume from them, but I am getting 20MB/s write speed and ~140-120MB/s read speed. Also there is quite low scatter for benchmark results (I am getting quite nice line) and it looks like controller is "capping" my speeds. I tried reseting controllers configuration and I haven't found any settings in HP ACU (Array Configuration Utility) to help me. I am using Windows 7 Ultimate and M4A78 board Does anyone have ideas what could be wrong? Also I am attaching diagnostic results.

    Read the article

  • Backup NAS to another NAS?

    - by Tronic
    hey there, is there a way to backup / transfer a NAS (it's like a big harddrive with some access to a webinterface, but closed linux etc.... only two ethernet ports) to another one? or is the only way to connect both NASs to my computer and copy the data from one to the other? it's like 750gb of data... thanks in advance... regards

    Read the article

  • Hard drive device names are different from one reboot to another in Ubuntu.

    - by Mike
    I have an Ubuntu machine (10.04 but had the same problem in 8.04) with a bunch of drives that I use as a file server. 1 SATA that I boot off of. 2 IDE that in RAID1 and 2 SATA in RAID1. The problem is the drives that I have in RAID1 change device names on reboot. This is a problem because the in my mdadm.conf a reference to /dev/sda1, for example, might not work the next time I reboot because /dev/sda1 could be a disk from another array. Any help getting around this would be appreciated. -Mike

    Read the article

  • Hard drive device names are different from one reboot to another in Ubuntu.

    - by Mike
    I have an Ubuntu machine (10.04 but had the same problem in 8.04) with a bunch of drives that I use as a file server. 1 SATA that I boot off of. 2 IDE that in RAID1 and 2 SATA in RAID1. The problem is the drives that I have in RAID1 change device names on reboot. This is a problem because the in my mdadm.conf a reference to /dev/sda1, for example, might not work the next time I reboot because /dev/sda1 could be a disk from another array. Any help getting around this would be appreciated. -Mike

    Read the article

  • Event Log: atapi - the device did not respond within the timeout period - Freeze

    - by rjlopes
    Hi, I have a Windows Server 2003 that stops working randomly (displays image on monitor but is completely frozen), all I could found on the event log as causes were an error from atapi and a warning from msas2k3. The event log entries are: Event Type: Error Event Source: atapi Event Category: None Event ID: 9 Date: 22-07-2009 Time: 16:13:33 User: N/A Computer: SERVER Description: The device, \Device\Ide\IdePort0, did not respond within the timeout period. For more information, see Help and Support Center at http : // go.microsoft.com / fwlink / events.asp. Data: 0000: 0f 00 10 00 01 00 64 00 ......d. 0008: 00 00 00 00 09 00 04 c0 .......À 0010: 01 01 00 50 00 00 00 00 ...P.... 0018: f8 06 20 00 00 00 00 00 ø. ..... 0020: 00 00 00 00 00 00 00 00 ........ 0028: 00 00 00 00 01 00 00 00 ........ 0030: 00 00 00 00 07 00 00 00 ........ Event Type: Warning Event Source: msas2k3 Event Category: None Event ID: 129 Date: 22-07-2009 Time: 16:14:23 User: N/A Computer: SERVER Description: Reset to device, \Device\RaidPort0, was issued. For more information, see Help and Support Center at http : // go.microsoft.com / fwlink / events.asp. Data: 0000: 0f 00 10 00 01 00 68 00 ......h. 0008: 00 00 00 00 81 00 04 80 ......? 0010: 04 00 00 00 00 00 00 00 ........ 0018: 00 00 00 00 00 00 00 00 ........ 0020: 00 00 00 00 00 00 00 00 ........ 0028: 00 00 00 00 00 00 00 00 ........ 0030: 01 00 00 00 81 00 04 80 ......? Any hints?

    Read the article

  • KVM guest io is much slower than host io: is that normal?

    - by Evolver
    I have a Qemu-KVM host system setup on CentOS 6.3. Four 1TB SATA HDDs working in Software RAID10. Guest CentOS 6.3 is installed on separate LVM. People say that they see guest performance almost equal to host performance, but I don't see that. My i/o tests are showing 30-70% slower performance on guest than on host system. I tried to change scheduler (set elevator=deadline on host and elevator=noop on guest), set blkio.weight to 1000 in cgroup, change io to virtio... But none of these changes gave me any significant results. This is a guest .xml config part: <disk type='file' device='disk'> <driver name='qemu' type='raw'/> <source file='/dev/vgkvmnode/lv2'/> <target dev='vda' bus='virtio'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x05' function='0x0'/> </disk> There are my tests: Host system: iozone test # iozone -a -i0 -i1 -i2 -s8G -r64k random random KB reclen write rewrite read reread read write 8388608 64 189930 197436 266786 267254 28644 66642 dd read test: one process and then four simultaneous processes # dd if=/dev/vgkvmnode/lv2 of=/dev/null bs=1M count=1024 iflag=direct 1073741824 bytes (1.1 GB) copied, 4.23044 s, 254 MB/s # dd if=/dev/vgkvmnode/lv2 of=/dev/null bs=1M count=1024 iflag=direct skip=1024 & dd if=/dev/vgkvmnode/lv2 of=/dev/null bs=1M count=1024 iflag=direct skip=2048 & dd if=/dev/vgkvmnode/lv2 of=/dev/null bs=1M count=1024 iflag=direct skip=3072 & dd if=/dev/vgkvmnode/lv2 of=/dev/null bs=1M count=1024 iflag=direct skip=4096 1073741824 bytes (1.1 GB) copied, 14.4528 s, 74.3 MB/s 1073741824 bytes (1.1 GB) copied, 14.562 s, 73.7 MB/s 1073741824 bytes (1.1 GB) copied, 14.6341 s, 73.4 MB/s 1073741824 bytes (1.1 GB) copied, 14.7006 s, 73.0 MB/s dd write test: one process and then four simultaneous processes # dd if=/dev/zero of=test bs=1M count=1024 oflag=direct 1073741824 bytes (1.1 GB) copied, 6.2039 s, 173 MB/s # dd if=/dev/zero of=test bs=1M count=1024 oflag=direct & dd if=/dev/zero of=test2 bs=1M count=1024 oflag=direct & dd if=/dev/zero of=test3 bs=1M count=1024 oflag=direct & dd if=/dev/zero of=test4 bs=1M count=1024 oflag=direct 1073741824 bytes (1.1 GB) copied, 32.7173 s, 32.8 MB/s 1073741824 bytes (1.1 GB) copied, 32.8868 s, 32.6 MB/s 1073741824 bytes (1.1 GB) copied, 32.9097 s, 32.6 MB/s 1073741824 bytes (1.1 GB) copied, 32.9688 s, 32.6 MB/s Guest system: iozone test # iozone -a -i0 -i1 -i2 -s512M -r64k random random KB reclen write rewrite read reread read write 524288 64 93374 154596 141193 149865 21394 46264 dd read test: one process and then four simultaneous processes # dd if=/dev/mapper/VolGroup-lv_home of=/dev/null bs=1M count=1024 iflag=direct skip=1024 1073741824 bytes (1.1 GB) copied, 5.04356 s, 213 MB/s # dd if=/dev/mapper/VolGroup-lv_home of=/dev/null bs=1M count=1024 iflag=direct skip=1024 & dd if=/dev/mapper/VolGroup-lv_home of=/dev/null bs=1M count=1024 iflag=direct skip=2048 & dd if=/dev/mapper/VolGroup-lv_home of=/dev/null bs=1M count=1024 iflag=direct skip=3072 & dd if=/dev/mapper/VolGroup-lv_home of=/dev/null bs=1M count=1024 iflag=direct skip=4096 1073741824 bytes (1.1 GB) copied, 24.7348 s, 43.4 MB/s 1073741824 bytes (1.1 GB) copied, 24.7378 s, 43.4 MB/s 1073741824 bytes (1.1 GB) copied, 24.7408 s, 43.4 MB/s 1073741824 bytes (1.1 GB) copied, 24.744 s, 43.4 MB/s dd write test: one process and then four simultaneous processes # dd if=/dev/zero of=test bs=1M count=1024 oflag=direct 1073741824 bytes (1.1 GB) copied, 10.415 s, 103 MB/s # dd if=/dev/zero of=test bs=1M count=1024 oflag=direct & dd if=/dev/zero of=test2 bs=1M count=1024 oflag=direct & dd if=/dev/zero of=test3 bs=1M count=1024 oflag=direct & dd if=/dev/zero of=test4 bs=1M count=1024 oflag=direct 1073741824 bytes (1.1 GB) copied, 49.8874 s, 21.5 MB/s 1073741824 bytes (1.1 GB) copied, 49.8608 s, 21.5 MB/s 1073741824 bytes (1.1 GB) copied, 49.8693 s, 21.5 MB/s 1073741824 bytes (1.1 GB) copied, 49.9427 s, 21.5 MB/s I wonder is that normal situation or did I missed something?

    Read the article

  • HP ML115 with P400 Smart Array Controller

    - by John
    Hi, I have a HP ML115 server I have installed a HP P400 Smart Array Controller card, I also have 4 x 1TB Samsung Hard drives. I'm unable to get the the controller to detect the hard drives, I have changed the drives to SATA 1.5G without luck, I have also tried connecting a single 80GB Maxtor drive without luck The controller shows up just after boot and tries to initialize, The controller does not show up in the POST prompt, although I can see the controller when booting off a ACU CD THe controller firmware is a little old v4.12 but I have no way to update it. Any ideas on how I can get this going?

    Read the article

  • SAS Array with or without expander

    - by tegbains
    Is it better to use a SAS Expander backplane for 12 drives via one SAS connection or is it better to use a SAS backplane with 3 SAS connections? This is in terms of performance, rather than expansion. This array will be setup using ZFS on a OpenSolaris via a LSI SAS controller as an iSCSI target. The two products being considered are the SuperMicro SuperChassis 826A-R1200LPB or the SuperChassis 826E2-R800LPB

    Read the article

  • Very poor SCSI hd performance on IBM x336 with LSI 1030 RAID1

    - by David Tschoepe
    I'm experiencing very poor performance on an IBM x336 server with dual 73GB 15k hard drives on a U320 controller, LSI 1030. We're getting maybe 3.5MB/sec max (per HD Tune utility). It should be over 100MB/sec at least, I would think (another x335 box is running 70-80MB/sec). The server was recently setup and didn't really notice the problem, but may have been there from the beginning, so not sure. I have installed the IBM ServerRAID Windows utility. The server is running Windows 2008 R2 Web edition (if that matters). I thought maybe one of the drives was bad, so far I have removed one of the drives out of the array and tested again, but still the same results. I'm waiting for the RAID1 to resync and I will try pulling the other drive next. I've also used the ServerRAID utility but haven't noticed anything in there that might indicate a problem. Not sure if I'm on the right path here. So looking for some advice to track this down.

    Read the article

  • Creating RAID1 on Windows Server causes not enough disk space error

    - by northpole
    I have three disks. Disk0 (boot), Disk1 and Disk2. Disk 1 and 2 are both unformatted and unallocated drives. I am trying to mirror Disk0 to Disk1. They are both Dynamic and are both the same size (1TB). When I select Disk1 to be the mirror I get the error "There is not enough space available on the disk(s) to complete this operation". I have spent several hours searching for a solution but have not found one. Why do I get this error when they are both the same size? EDIT: Shrinking the volume size on the boot disk by 100MB allowed me to get past this error. From what I read the mirror drive needs to be the same size or larger than the boot drive. So I am confused why that change worked. However, I now get the error " all disks holding extents for a given volume must have the same sector size and the sector size must be valid". I believe this is because the drives are different and one has 512B and the other is the Advanced Drive that is 4KB. What the different sector sizes cause both problems? If I got the same disks would both issues go away?

    Read the article

  • Windows 7 - cancel mirror synchronisation

    - by Chris W
    I've got basic disk OS managed disk mirroring setup in Windows 7 for a couple of volumes. After a power failure the mirrors are currently resynching. These are only small volumes of data but the sync has not completed after more than 24 hours. Is there any way to stop this as it's driving me nuts? I need to get the machine back to a usable state to get some work done but it's a bit of a dog whilst this synch is going on. I've tried removing the mirrors but it won't let me do that whilst the re-sync is in progress.

    Read the article

  • Windows 7 - cancel mirror synchronisation

    - by Chris W
    I've got basic disk OS managed disk mirroring setup in Windows 7 for a couple of volumes. After a power failure the mirrors are currently resynching. These are only small volumes of data but the sync has not completed after more than 24 hours. Is there any way to stop this as it's driving me nuts? I need to get the machine back to a usable state to get some work done but it's a bit of a dog whilst this synch is going on. I've tried removing the mirrors but it won't let me do that whilst the re-sync is in progress.

    Read the article

  • prevent filesystem from entering read-only mode

    - by user788171
    I have found that my server's filesystem is continuously entering read-only mode. There have been some issues with the raid1 array, but I have removed the bad disk from the array. However, it is still physically plugged into the system because I haven't had a chance to go over to the datacentre, I suspect udev and the system kernel is still picking up the bad disk and throwing errors. In /var/log/messages, there are errors like this: Mar 2 06:53:14 nocloud kernel: ata1: exception Emask 0x10 SAct 0x0 SErr 0x4010000 action 0xe frozen Mar 2 06:53:14 nocloud kernel: ata1: irq_stat 0x00400040, connection status changed Mar 2 06:53:14 nocloud kernel: ata1: SError: { PHYRdyChg DevExch } Mar 2 06:53:14 nocloud kernel: ata1: hard resetting link Mar 2 06:53:20 nocloud kernel: ata1: link is slow to respond, please be patient (ready=0) Mar 2 06:53:21 nocloud kernel: ata1: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Mar 2 06:53:21 nocloud kernel: ata1.00: configured for UDMA/133 Mar 2 06:53:21 nocloud kernel: ata1: EH complete This happens fairly randomly throughout the day until eventually the filesystem becomes read-only. When this happens, my system becomes non-operational which kind of defeats the purpose of having a raid1. Note, ata1 is the bad disk (I think ata1 corresponds to /dev/sda because they are both first in line). Under mdadm, /dev/sda1,2 is no longer being used, but I can't prevent the system kernel from continuing to query that disk when I am no longer using it and throwing these errors. Is there a way to prevent my filesystem from automatically going into read-only mode? Furthermore, is it safe to do so? Thanks in advance. EDIT: Additional information: output from cat /proc/mdstat md1 : active raid1 sdb2[1] 976554876 blocks super 1.1 [2/1] [_U] bitmap: 5/8 pages [20KB], 65536KB chunk md0 : active raid1 sdb1[1] 204788 blocks super 1.0 [2/1] [_U] Output from mount: /dev/mapper/VolGroup-LogVol00 on / type ext4 (rw,noatime) proc on /proc type proc (rw) sysfs on /sys type sysfs (rw) devpts on /dev/pts type devpts (rw,gid=5,mode=620) tmpfs on /dev/shm type tmpfs (rw,rootcontext="system_u:object_r:tmpfs_t:s0") /dev/md0 on /boot type ext4 (rw) none on /proc/sys/fs/binfmt_misc type binfmt_misc (rw) sunrpc on /var/lib/nfs/rpc_pipefs type rpc_pipefs (rw) EDIT2: pvdisplay output: --- Physical volume --- PV Name /dev/md1 VG Name VolGroup PV Size 931.32 GiB / not usable 2.87 MiB Allocatable yes (but full) PE Size 16.00 MiB Total PE 59604 Free PE 0 Allocated PE 59604

    Read the article

< Previous Page | 46 47 48 49 50 51 52 53 54 55 56 57  | Next Page >