Search Results

Search found 22914 results on 917 pages for 'solid state drive'.

Page 50/917 | < Previous Page | 46 47 48 49 50 51 52 53 54 55 56 57  | Next Page >

  • Do I need to be worried about these SMART drive temperatures?

    - by Steve Lorimer
    I have 5 hard drives in a machine sitting in a cupboard. /dev/sda is a 500GB Seagate drive, and is the boot disk. /dev/sd{b,c,d,e} are 2TB drives in a raid6 configuration. smartctl is showing significantly higher temperatures (like ~140 degrees celsius) on the raid drives than the boot drive. Do I need to be worried? /dev/sdb and /dev/sde are new Western Digital Black drives (new=1 week) /dev/sdc and /dev/sdd are 5 year old Hitachi drives /dev/sda [SAT], Temperature_Celsius changed from 40 to 39 /dev/sdc [SAT], Temperature_Celsius changed from 142 to 146 /dev/sdc [SAT], Temperature_Celsius changed from 146 to 142 /dev/sdd [SAT], Temperature_Celsius changed from 142 to 146 /dev/sda [SAT], Airflow_Temperature_Cel changed from 61 to 62 /dev/sda [SAT], Temperature_Celsius changed from 39 to 38 /dev/sde [SAT], Temperature_Celsius changed from 107 to 108 /dev/sdb [SAT], Temperature_Celsius changed from 108 to 109 /dev/sdc [SAT], Temperature_Celsius changed from 146 to 150 /dev/sdc [SAT], Temperature_Celsius changed from 146 to 150 /dev/sda [SAT], Airflow_Temperature_Cel changed from 62 to 61 /dev/sda [SAT], Temperature_Celsius changed from 38 to 39 Update: Adding detailed drive information as per request: /dev/sda =========================== smartctl 6.0 2012-10-10 r3643 [x86_64-linux-3.9.10-100.fc17.x86_64] (local build) Copyright (C) 2002-12, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Seagate Pipeline HD 5900.2 Device Model: ST3500312CS Serial Number: 5VV47HXA LU WWN Device Id: 5 000c50 02aad5ad6 Firmware Version: SC13 User Capacity: 500,107,862,016 bytes [500 GB] Sector Size: 512 bytes logical/physical Rotation Rate: 5900 rpm Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 2.6, 1.5 Gb/s (current: 1.5 Gb/s) Local Time is: Tue Jun 3 10:54:11 2014 EST SMART support is: Available - device has SMART capability. SMART support is: Enabled /dev/sdb =========================== smartctl 6.0 2012-10-10 r3643 [x86_64-linux-3.9.10-100.fc17.x86_64] (local build) Copyright (C) 2002-12, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: WDC WD2003FZEX-00Z4SA0 Serial Number: WD-WMC1F1398726 LU WWN Device Id: 5 0014ee 003b8bd25 Firmware Version: 01.01A01 User Capacity: 2,000,398,934,016 bytes [2.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 7200 rpm Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-2 (minor revision not indicated) SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Tue Jun 3 10:54:11 2014 EST SMART support is: Available - device has SMART capability. SMART support is: Enabled /dev/sdc =========================== smartctl 6.0 2012-10-10 r3643 [x86_64-linux-3.9.10-100.fc17.x86_64] (local build) Copyright (C) 2002-12, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Hitachi Deskstar 7K3000 Device Model: Hitachi HDS723020BLA642 Serial Number: MN1220F30WSTUD LU WWN Device Id: 5 000cca 369cc9f5d Firmware Version: MN6OA580 User Capacity: 2,000,398,934,016 bytes [2.00 TB] Sector Size: 512 bytes logical/physical Rotation Rate: 7200 rpm Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 2.6, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Tue Jun 3 10:54:11 2014 EST SMART support is: Available - device has SMART capability. SMART support is: Enabled /dev/sdd =========================== smartctl 6.0 2012-10-10 r3643 [x86_64-linux-3.9.10-100.fc17.x86_64] (local build) Copyright (C) 2002-12, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Hitachi Deskstar 7K3000 Device Model: Hitachi HDS723020BLA642 Serial Number: MN1220F30WST4D LU WWN Device Id: 5 000cca 369cc9f48 Firmware Version: MN6OA580 User Capacity: 2,000,398,934,016 bytes [2.00 TB] Sector Size: 512 bytes logical/physical Rotation Rate: 7200 rpm Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 2.6, 6.0 Gb/s (current: 1.5 Gb/s) Local Time is: Tue Jun 3 10:54:11 2014 EST SMART support is: Available - device has SMART capability. SMART support is: Enabled /dev/sde =========================== smartctl 6.0 2012-10-10 r3643 [x86_64-linux-3.9.10-100.fc17.x86_64] (local build) Copyright (C) 2002-12, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: WDC WD2003FZEX-00Z4SA0 Serial Number: WD-WMC1F1483782 LU WWN Device Id: 5 0014ee 3002d235c Firmware Version: 01.01A01 User Capacity: 2,000,398,934,016 bytes [2.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 7200 rpm Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-2 (minor revision not indicated) SATA Version is: SATA 3.0, 6.0 Gb/s (current: 1.5 Gb/s) Local Time is: Tue Jun 3 10:54:11 2014 EST SMART support is: Available - device has SMART capability. SMART support is: Enabled

    Read the article

  • How to backup a NAS drive to a USB drive?

    - by Tim Murphy
    How would you backup 600+ GB of data on a NAS (Network-Attached Storage) drive to a USB external drive? The NAS drive does not contain mission critical data nonetheless I wish to make weekly copies of it just in case. The NAS drive is almost exclusively used as an archive dump and is rarely updated. However the backup strategy used must have a simple restore procedure so I can confidently say the data now on the NAS drive is exactly how it was at the time of backup. I did try xcopy but seemed like it would take many-many hours and eventually crashed with insufficient memory. http://www.ctunion.com/node/114 suggests I would need to use xxcopy instead due to folder/file name lengths. My concern with xcopy/xxcopy is the length of time it takes. Hoping something else is faster. NAS drive is DLink DNS-313. 1TB drive installed. Connected to router via Ethernet cable. USB drive is Seagate 1TB. Can be connected to Windows Vista (preferred) or Windows 7 PCs. Both PCs are usually connected Wirelessly however ethernet cable can be used during backup to speed up the process.

    Read the article

  • What is the quickest reliable way to backup a NAS drive to a USB drive?

    - by Tim Murphy
    How would you backup 600+ GB of data on a NAS (Network-Attached Storage) drive to a USB external drive? The NAS drive does not contain mission critical data nonetheless I wish to make weekly copies of it just in case. The NAS drive is almost exclusively used as an archive dump and is rarely updated. However the backup strategy used must have a simple restore procedure so I can confidently say the data now on the NAS drive is exactly how it was at the time of backup. I did try xcopy but seemed like it would take many-many hours and eventually crashed with insufficient memory. http://www.ctunion.com/node/114 suggests I would need to use xxcopy instead due to folder/file name lengths. My concern with xcopy/xxcopy is the length of time it takes. Hoping something else is faster. NAS drive is DLink DNS-313. 1TB drive installed. Connected to router via Ethernet cable. USB drive is Seagate 1TB. Can be connected to Windows Vista (preferred) or Windows 7 PCs. Both PCs are usually connected Wirelessly however ethernet cable can be used during backup to speed up the process.

    Read the article

  • File copying utility like rsync with error handling like ddrescue, for data recovery from a hard drive with bad sectors or hardware failure

    - by purefusion
    I have a hard drive with either bad blocks or sectors that are failing to read due to potential mechanical issues, such as a bad disk head, bad motor, or some other issue that is causing the hard drive to read data excruciatingly slowly and with lots of read errors. I'm seeing an average of 50 KB/sec, with some reads dropping below 10 KB/sec, and frequently it gets stuck on a file or sector altogether, usually for quite a long time—from 2-10 minutes or more (when using rsync, before it times out). Speed seems to vary wildly, and it gets stuck on files a lot, and when it finally gets "unstuck" it only seems to last for a short burst before it gets stuck again. The drive is also very quiet with only an occasional sound of files copying (usually when it gets stuck/unstuck for a brief time, before getting stuck again). Thus, there are none of those evil sounds that are normally associated with HDD death. Someone suggested that the problems sounded like they might be caused by a misaligned disk head, which requires a lot of re-reads before it finally reads data with success. Sounds plausible, but I digress... Anyway, the problem with rsync is that it seems to have no decent error handling support. Obviously, it wasn't meant for use in recovering data from failing hard drives, but all the so-called "data recovery" utilities out there that are meant for such use usually focus on recovery of deleted files or messed up partitions, rather than copying files off dying hard drives. Deleted file recovery is not what I need, obviously, so perhaps you can understand my disappointment in not being able to find what I'm after yet. Naturally, this is where you'd probably say "You should use ddrescue!" Well, that's all fine and dandy, but I've already got most of the data backed up, so I just want to recover certain files. I'm not concerned with trying to recover a full partition block-by-block as ddrescue does. I am only interested in rescuing just specific files and directories. Ideally, what I'd like is some sort of cross between rsync and ddrescue: something that lets me specify source and destination as directories of normal files like rsync (rather than two full partitions as ddrescue requires), with a way to skip files with errors in an initial run, and then allows me to attempt recovery of those files with errors in a later run (with a slightly altered command, of course), perhaps even offering an option to specify the number of retry attempts ...just like how ddrescue works with blocks, only I want a utility that works with specific files/directories like rsync does. So am I daydreaming here, or does something out there exist that can do this? Or, maybe even a way to make rsync or ddrescue work in such a way? I'm really open to whatever solutions might work, so long as they let me choose which files I want to "rescue", and can skip files with errors in the initial run, and try/retry those errors again later. So far I've tried rsync with the following options, but it often gets stuck on a file for longer than the timeout, and ideally I'd just like it to move on to the next file and come back later to the files it gets stuck on. I don't think that's possible though. Anyway, here's what I've been using up till now: rsync -avP --stats --block-size=512 --timeout=600 /path/to/source/* /path/to/destination/

    Read the article

  • Can't detect hard drive on Macbook Pro

    - by MartinMoizard
    I changed a few month ago the config of my Macbook Pro with the following: I bought a SSD hard drive I removed the hard drive of my Mac book Pro and installed there my brand new SSD Then I removed my DVD drive and installed my hold hard drive instead with a caddy Everything was working great until today when I couldn't access anymore to my old hard drive because it is not detected anymore. Sometimes Mac OSX is mounting it but it takes like 15 min to browse a simple folder. I opened my laptop to have a look at the problem. It seemed like the optical drive connector was not plugged correctly to the motherboard (that connector: http://cl.ly/2T0X2e1j0J1g47061d1t). So I plugged it correctly and reboot. It didn't fix my problem. Then I tried to put my SSD in the caddy and to boot: no hard drive was detected. So I guess there is something wrong either with the caddy, either with the optical drive connector, or either with the plug that is on the motherboard. So my question is, how can I know where the problem comes from?

    Read the article

  • Installed Windows 7 Ultimate on D Drive and previous Windows 7 Enterprise on C Drive has stopped starting up

    - by teenup
    Please please help! I have installed Windows 7 Ultimate on same hard drive on D Drive on my laptop and the previous Windows 7 Enterprise which was installed on C Drive is not booting up now. When I turn on my laptop, I see two Windows 7 on the screen, when I select newer one, it starts, but when I select older one which is Enterprise edition, system won't start and I get the DOS black screen with this error message: Windows Boot Manager Windows failed to start. A recent hardware or software change might be the cause. To fix the problem: Insert your Windows installation disc and restart your computer. Choose your language settings, and then click "Next." Click "repair your computer." Info: The boot selection failed because a required device is inaccessible. I notice that when I run the newer OS installed, the previous OS's drive (Which is D: now instead of C:) has become unusable and when I double click it, it asks me to format the drive. The data, that I had on my D Drive (Which is now C Drive for new OS), I had copied it to a network path and it is available. It was containing Windows 7 Users folder which I copied at that time when installing new windows. I have copied that Users folder again to the new OS's C Drive thinking it would run again, but of no use. Please please please...if someone can help...It is extremely required for me. Thanks a lot in advance.

    Read the article

  • JFreeChart - change SeriesStroke of chart lines from solid to dashed in one line

    - by MisterMichaelK
    The answer accepted here (JFreechart(Java) - How to draw lines that is partially dashed lines and partially solid lines?) helped me start down the path of changing my seriesstroke lines on my chart. After stepping through my code and watching the changes, I see that my seriesstroke does in fact change to "dashedStroke" when it is supposed to (after a certain date "dai"), but when the chart is rendered the entire series line is dashed. How can I get a series line to be drawn solid at first and dashed after a set date? /* series line modifications */ final Number dashedAfter = timeNowDate.getTime(); final int dai = Integer.parseInt(ndf.format(timeNowDate)); XYLineAndShapeRenderer render = new XYLineAndShapeRenderer() { Stroke regularStroke = new BasicStroke(); Stroke dashedStroke = new BasicStroke( 1.0f, BasicStroke.CAP_ROUND, BasicStroke.JOIN_ROUND, 1.0f, new float[] {10.0f, 6.0f}, 0.0f ); @Override public Stroke getItemStroke(int row, int column) { Number xVal = cd.getXValue(row, column); int xiv = xVal.intValue(); if (xVal.doubleValue() > dashedAfter.doubleValue()) { return dashedStroke; } else { return regularStroke; } } }; plot.setRenderer(render);

    Read the article

  • Hard Disk Space Changes

    - by Write.
    I am currently running on Windows 7 x64, and have observe that my hard disk space is acting a little weird. Currently, my harddisk has 3 partitions, C:, D:, E:. Previously, before I delete a huge folder (30gb of data) from my D: drive, my C: drive has about 1gb left, while my E: drive has about 5 gb left. After deleting the 30gb of data (from D: drive), my space in D: drive has been recovered (but not sure if it's fully recovered), my C: drive which only had about 1gb left increased to 3. While my E: drive which had 5gb left dropped to 1. I was wondering if it has something to do with the fragmentations and whatsoever I always hear about in harddisk. Has anyone encountered similar issues or have an explanation to why it could be happening?

    Read the article

  • Can hard drives experience magnetic interference from a server chassis?

    - by eek142
    I'm currently building a server, and it's exhibiting the weirdest behavior with the hard drive. It is a 2U case, and I have trouble trouble accessing the Seagate SATAIII hard drive when it is in the bottom slot of the hard drive cage. The case is made of galvanized/anodized steel. I thought the drive was DOA, but then I swapped it into the top slot, and the problem was solved--the system had no trouble recognizing the drive anymore! This got me thinking: Is it possible that the magnetic field from the chassis was affecting the hard drive's functionality? I only have this problem with the mechanical hard drive, not the SSD. Could it be because the chassis is made of steel? I'm baffled.

    Read the article

  • How to have file/folder icons use a relative path?

    - by Memor-X
    On my portable hard drive I set icons for almost every organized folder. All these icons are located in an Icons folder located on the root directory of the same hard drive. When I change the drive letter of the hard drive (well I don't, windows does automatically sometimes) these icons are lost. So far this hard drive is assigned to F: While it's not a problem now, it may becomes a problem if I upgrade my computer or get a new one and the F: Drive is already taken up for something else. It's also annoying on networks where F: is mapped to a network drive.

    Read the article

  • External HDD USB 3.0 failure

    - by Philip
    [ 2560.376113] usb 9-1: new high-speed USB device number 2 using xhci_hcd [ 2560.376186] usb 9-1: Device not responding to set address. [ 2560.580136] usb 9-1: Device not responding to set address. [ 2560.784104] usb 9-1: device not accepting address 2, error -71 [ 2560.840127] hub 9-0:1.0: unable to enumerate USB device on port 1 [ 2561.080182] usb 10-1: new SuperSpeed USB device number 5 using xhci_hcd [ 2566.096163] usb 10-1: device descriptor read/8, error -110 [ 2566.200096] usb 10-1: new SuperSpeed USB device number 5 using xhci_hcd [ 2571.216175] usb 10-1: device descriptor read/8, error -110 [ 2571.376138] hub 10-0:1.0: unable to enumerate USB device on port 1 [ 2571.744174] usb 10-1: new SuperSpeed USB device number 7 using xhci_hcd [ 2576.760116] usb 10-1: device descriptor read/8, error -110 [ 2576.864074] usb 10-1: new SuperSpeed USB device number 7 using xhci_hcd [ 2581.880153] usb 10-1: device descriptor read/8, error -110 [ 2582.040123] hub 10-0:1.0: unable to enumerate USB device on port 1 [ 2582.224139] hub 9-0:1.0: unable to enumerate USB device on port 1 [ 2582.464177] usb 10-1: new SuperSpeed USB device number 9 using xhci_hcd [ 2587.480122] usb 10-1: device descriptor read/8, error -110 [ 2587.584079] usb 10-1: new SuperSpeed USB device number 9 using xhci_hcd [ 2592.600150] usb 10-1: device descriptor read/8, error -110 [ 2592.760134] hub 10-0:1.0: unable to enumerate USB device on port 1 [ 2593.128175] usb 10-1: new SuperSpeed USB device number 11 using xhci_hcd [ 2598.144183] usb 10-1: device descriptor read/8, error -110 [ 2598.248109] usb 10-1: new SuperSpeed USB device number 11 using xhci_hcd [ 2603.264171] usb 10-1: device descriptor read/8, error -110 [ 2603.480157] usb 10-1: new SuperSpeed USB device number 12 using xhci_hcd [ 2608.496162] usb 10-1: device descriptor read/8, error -110 [ 2608.600091] usb 10-1: new SuperSpeed USB device number 12 using xhci_hcd [ 2613.616166] usb 10-1: device descriptor read/8, error -110 [ 2613.832170] usb 10-1: new SuperSpeed USB device number 13 using xhci_hcd [ 2618.848135] usb 10-1: device descriptor read/8, error -110 [ 2618.952079] usb 10-1: new SuperSpeed USB device number 13 using xhci_hcd [ 2623.968155] usb 10-1: device descriptor read/8, error -110 [ 2624.184176] usb 10-1: new SuperSpeed USB device number 14 using xhci_hcd [ 2629.200124] usb 10-1: device descriptor read/8, error -110 [ 2629.304075] usb 10-1: new SuperSpeed USB device number 14 using xhci_hcd [ 2634.320172] usb 10-1: device descriptor read/8, error -110 [ 2634.424135] hub 10-0:1.0: unable to enumerate USB device on port 1 [ 2634.776186] usb 10-1: new SuperSpeed USB device number 15 using xhci_hcd [ 2639.792105] usb 10-1: device descriptor read/8, error -110 [ 2639.896090] usb 10-1: new SuperSpeed USB device number 15 using xhci_hcd [ 2644.912172] usb 10-1: device descriptor read/8, error -110 [ 2645.128174] usb 10-1: new SuperSpeed USB device number 16 using xhci_hcd [ 2650.144160] usb 10-1: device descriptor read/8, error -110 [ 2650.248062] usb 10-1: new SuperSpeed USB device number 16 using xhci_hcd [ 2655.264120] usb 10-1: device descriptor read/8, error -110 [ 2655.480182] usb 10-1: new SuperSpeed USB device number 17 using xhci_hcd [ 2660.496121] usb 10-1: device descriptor read/8, error -110 [ 2660.600086] usb 10-1: new SuperSpeed USB device number 17 using xhci_hcd [ 2665.616167] usb 10-1: device descriptor read/8, error -110 [ 2665.832177] usb 10-1: new SuperSpeed USB device number 18 using xhci_hcd [ 2670.848110] usb 10-1: device descriptor read/8, error -110 [ 2670.952066] usb 10-1: new SuperSpeed USB device number 18 using xhci_hcd [ 2675.968081] usb 10-1: device descriptor read/8, error -110 [ 2676.072124] hub 10-0:1.0: unable to enumerate USB device on port 1 [ 2786.104531] xhci_hcd 0000:02:00.0: remove, state 4 [ 2786.104546] usb usb10: USB disconnect, device number 1 [ 2786.104686] xHCI xhci_drop_endpoint called for root hub [ 2786.104692] xHCI xhci_check_bandwidth called for root hub [ 2786.104942] xhci_hcd 0000:02:00.0: USB bus 10 deregistered [ 2786.105054] xhci_hcd 0000:02:00.0: remove, state 4 [ 2786.105065] usb usb9: USB disconnect, device number 1 [ 2786.105176] xHCI xhci_drop_endpoint called for root hub [ 2786.105181] xHCI xhci_check_bandwidth called for root hub [ 2786.109787] xhci_hcd 0000:02:00.0: USB bus 9 deregistered [ 2786.110134] xhci_hcd 0000:02:00.0: PCI INT A disabled [ 2794.268445] pci 0000:02:00.0: [1b73:1000] type 0 class 0x000c03 [ 2794.268483] pci 0000:02:00.0: reg 10: [mem 0x00000000-0x0000ffff] [ 2794.268689] pci 0000:02:00.0: PME# supported from D0 D3hot [ 2794.268700] pci 0000:02:00.0: PME# disabled [ 2794.276383] pci 0000:02:00.0: BAR 0: assigned [mem 0xd7800000-0xd780ffff] [ 2794.276398] pci 0000:02:00.0: BAR 0: set to [mem 0xd7800000-0xd780ffff] (PCI address [0xd7800000-0xd780ffff]) [ 2794.276419] pci 0000:02:00.0: no hotplug settings from platform [ 2794.276658] xhci_hcd 0000:02:00.0: enabling device (0000 -> 0002) [ 2794.276675] xhci_hcd 0000:02:00.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 2794.276762] xhci_hcd 0000:02:00.0: setting latency timer to 64 [ 2794.276771] xhci_hcd 0000:02:00.0: xHCI Host Controller [ 2794.276913] xhci_hcd 0000:02:00.0: new USB bus registered, assigned bus number 9 [ 2794.395760] xhci_hcd 0000:02:00.0: irq 16, io mem 0xd7800000 [ 2794.396141] xHCI xhci_add_endpoint called for root hub [ 2794.396144] xHCI xhci_check_bandwidth called for root hub [ 2794.396195] hub 9-0:1.0: USB hub found [ 2794.396203] hub 9-0:1.0: 1 port detected [ 2794.396305] xhci_hcd 0000:02:00.0: xHCI Host Controller [ 2794.396371] xhci_hcd 0000:02:00.0: new USB bus registered, assigned bus number 10 [ 2794.396496] xHCI xhci_add_endpoint called for root hub [ 2794.396499] xHCI xhci_check_bandwidth called for root hub [ 2794.396547] hub 10-0:1.0: USB hub found [ 2794.396553] hub 10-0:1.0: 1 port detected [ 2798.004084] usb 1-3: new high-speed USB device number 8 using ehci_hcd [ 2798.140824] scsi21 : usb-storage 1-3:1.0 [ 2820.176116] usb 1-3: reset high-speed USB device number 8 using ehci_hcd [ 2824.000526] scsi 21:0:0:0: Direct-Access BUFFALO HD-PZU3 0001 PQ: 0 ANSI: 6 [ 2824.002263] sd 21:0:0:0: Attached scsi generic sg2 type 0 [ 2824.003617] sd 21:0:0:0: [sdb] 1953463728 512-byte logical blocks: (1.00 TB/931 GiB) [ 2824.005139] sd 21:0:0:0: [sdb] Write Protect is off [ 2824.005149] sd 21:0:0:0: [sdb] Mode Sense: 1f 00 00 08 [ 2824.009084] sd 21:0:0:0: [sdb] No Caching mode page present [ 2824.009094] sd 21:0:0:0: [sdb] Assuming drive cache: write through [ 2824.011944] sd 21:0:0:0: [sdb] No Caching mode page present [ 2824.011952] sd 21:0:0:0: [sdb] Assuming drive cache: write through [ 2824.049153] sdb: sdb1 [ 2824.051814] sd 21:0:0:0: [sdb] No Caching mode page present [ 2824.051821] sd 21:0:0:0: [sdb] Assuming drive cache: write through [ 2824.051825] sd 21:0:0:0: [sdb] Attached SCSI disk [ 2839.536624] usb 1-3: USB disconnect, device number 8 [ 2844.620178] usb 10-1: new SuperSpeed USB device number 2 using xhci_hcd [ 2844.640281] scsi22 : usb-storage 10-1:1.0 [ 2850.326545] scsi 22:0:0:0: Direct-Access BUFFALO HD-PZU3 0001 PQ: 0 ANSI: 6 [ 2850.327560] sd 22:0:0:0: Attached scsi generic sg2 type 0 [ 2850.329561] sd 22:0:0:0: [sdb] 1953463728 512-byte logical blocks: (1.00 TB/931 GiB) [ 2850.329889] sd 22:0:0:0: [sdb] Write Protect is off [ 2850.329897] sd 22:0:0:0: [sdb] Mode Sense: 1f 00 00 08 [ 2850.330223] sd 22:0:0:0: [sdb] No Caching mode page present [ 2850.330231] sd 22:0:0:0: [sdb] Assuming drive cache: write through [ 2850.331414] sd 22:0:0:0: [sdb] No Caching mode page present [ 2850.331423] sd 22:0:0:0: [sdb] Assuming drive cache: write through [ 2850.384116] usb 10-1: USB disconnect, device number 2 [ 2850.392050] sd 22:0:0:0: [sdb] Unhandled error code [ 2850.392056] sd 22:0:0:0: [sdb] Result: hostbyte=DID_NO_CONNECT driverbyte=DRIVER_OK [ 2850.392061] sd 22:0:0:0: [sdb] CDB: Read(10): 28 00 00 00 00 00 00 00 08 00 [ 2850.392074] end_request: I/O error, dev sdb, sector 0 [ 2850.392079] quiet_error: 70 callbacks suppressed [ 2850.392082] Buffer I/O error on device sdb, logical block 0 [ 2850.392194] ldm_validate_partition_table(): Disk read failed. [ 2850.392271] Dev sdb: unable to read RDB block 0 [ 2850.392377] sdb: unable to read partition table [ 2850.392581] sd 22:0:0:0: [sdb] READ CAPACITY failed [ 2850.392584] sd 22:0:0:0: [sdb] Result: hostbyte=DID_NO_CONNECT driverbyte=DRIVER_OK [ 2850.392588] sd 22:0:0:0: [sdb] Sense not available. [ 2850.392613] sd 22:0:0:0: [sdb] Asking for cache data failed [ 2850.392617] sd 22:0:0:0: [sdb] Assuming drive cache: write through [ 2850.392621] sd 22:0:0:0: [sdb] Attached SCSI disk [ 2850.732182] usb 10-1: new SuperSpeed USB device number 3 using xhci_hcd [ 2850.752228] scsi23 : usb-storage 10-1:1.0 [ 2851.752709] scsi 23:0:0:0: Direct-Access BUFFALO HD-PZU3 0001 PQ: 0 ANSI: 6 [ 2851.754481] sd 23:0:0:0: Attached scsi generic sg2 type 0 [ 2851.756576] sd 23:0:0:0: [sdb] 1953463728 512-byte logical blocks: (1.00 TB/931 GiB) [ 2851.758426] sd 23:0:0:0: [sdb] Write Protect is off [ 2851.758436] sd 23:0:0:0: [sdb] Mode Sense: 1f 00 00 08 [ 2851.758779] sd 23:0:0:0: [sdb] No Caching mode page present [ 2851.758787] sd 23:0:0:0: [sdb] Assuming drive cache: write through [ 2851.759968] sd 23:0:0:0: [sdb] No Caching mode page present [ 2851.759977] sd 23:0:0:0: [sdb] Assuming drive cache: write through [ 2851.817710] sdb: sdb1 [ 2851.820562] sd 23:0:0:0: [sdb] No Caching mode page present [ 2851.820568] sd 23:0:0:0: [sdb] Assuming drive cache: write through [ 2851.820572] sd 23:0:0:0: [sdb] Attached SCSI disk [ 2852.060352] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2852.076533] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2852.076538] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2852.196329] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2852.212593] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2852.212599] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2852.456290] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2852.472402] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2852.472408] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2852.624304] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2852.640531] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2852.640536] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2852.772296] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2852.788536] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2852.788541] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2852.920349] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2852.936536] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2852.936540] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2853.072287] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2853.088565] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2853.088570] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2884.176339] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2884.192561] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2884.192567] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2884.320349] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2884.336526] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2884.336531] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2884.468344] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2884.484551] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2884.484556] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2884.612349] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2884.628540] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2884.628545] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2884.756350] usb 10-1: reset SuperSpeed USB device number 3 using xhci_hcd [ 2884.772528] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b19060 [ 2884.772533] xhci_hcd 0000:02:00.0: xHCI xhci_drop_endpoint called with disabled ep f6b1908c [ 2884.848116] usb 10-1: USB disconnect, device number 3 [ 2884.851493] scsi 23:0:0:0: [sdb] killing request [ 2884.851501] scsi 23:0:0:0: [sdb] killing request [ 2884.851699] scsi 23:0:0:0: [sdb] Unhandled error code [ 2884.851702] scsi 23:0:0:0: [sdb] Result: hostbyte=DID_NO_CONNECT driverbyte=DRIVER_OK [ 2884.851708] scsi 23:0:0:0: [sdb] CDB: Read(10): 28 00 00 5f 2b ee 00 00 3e 00 [ 2884.851721] end_request: I/O error, dev sdb, sector 6237166 [ 2884.851726] Buffer I/O error on device sdb1, logical block 6237102 [ 2884.851730] Buffer I/O error on device sdb1, logical block 6237103 [ 2884.851738] Buffer I/O error on device sdb1, logical block 6237104 [ 2884.851741] Buffer I/O error on device sdb1, logical block 6237105 [ 2884.851744] Buffer I/O error on device sdb1, logical block 6237106 [ 2884.851747] Buffer I/O error on device sdb1, logical block 6237107 [ 2884.851750] Buffer I/O error on device sdb1, logical block 6237108 [ 2884.851753] Buffer I/O error on device sdb1, logical block 6237109 [ 2884.851757] Buffer I/O error on device sdb1, logical block 6237110 [ 2884.851807] scsi 23:0:0:0: [sdb] Unhandled error code [ 2884.851810] scsi 23:0:0:0: [sdb] Result: hostbyte=DID_NO_CONNECT driverbyte=DRIVER_OK [ 2884.851813] scsi 23:0:0:0: [sdb] CDB: Read(10): 28 00 00 5f 2c 2c 00 00 3e 00 [ 2884.851824] end_request: I/O error, dev sdb, sector 6237228 [ 2885.168190] usb 10-1: new SuperSpeed USB device number 4 using xhci_hcd [ 2885.188268] scsi24 : usb-storage 10-1:1.0 Please help me with my problem. I got this after running dmesg.

    Read the article

  • Diagram that could explain a state machine's code?

    - by Incognito
    We have a lot of concepts in making diagrams like UML and flowcharting or just making up whatever boxes-and-arrows combination works at the time, but I'm looking at doing a visual diagram on something that's actually really complex. State machines like those that parse HTML or regular expressions tend to be very long and complicated bits of code. For example, this is the stateLoop for FireFox 9 beta. It's actually generated by another file, but this is the code that runs. How can I diagram something with the complexity of this in a way that explains flow of the code without taking it to a level where I draw every single line-of-code into it's own box on a flowchart? I don't want to draw "Invoke loop, then return" but I don't want to explain every last detail. What kind of graph is suitable to do this? Is there already something out there similar to this? Just an example of how to do this without going overboard in complexity or too-high-level is really what I want. If you don't feel like looking at the code, basically it's 70 different state flags that could occur, inside an infinite loop that exists to a label based on some conditions, each flag has it's own infinite loop that exists to a label somewhere, and each of those loops has checks for different types of chars, which then runs off into various other methods.

    Read the article

  • Fix Package is in a very bad inconsistent state

    - by Benjamin Piller
    I can't update my system because it freezes while installing a third-party update (zramswap-enabler)!! Sometimes I get the following message in Update manager: Could not initialize the package information An unresolvable problem occurred while initializing the package information. Please report this bug against the 'update-manager' package and include the following error message: E:The package zramswap-enabler needs to be reinstalled, but I can't find an archive for it. I tried to remove the zramswap-enabler, but it's impossible because I get the following message: dpkg: error processing zramswap-enabler (--remove): Package is in a very bad inconsistent state - you should reinstall it before attempting a removal. Errors were encountered while processing: zramswap-enabler E: Sub-process /usr/bin/dpkg returned an error code (1) Actually i would really reinstall that package, but it is unable to do it! If i remove this third-party PPA then the system is warning me about a very very serious problem. So why can i not install/reinstall/remove/update this package and why freezes the updater if i try to update? -S O L U T I O N-: Okay! Finally i found the solution for this Problem! Step 1. Make sure that your PPA is correctly Step 2. Remove the broken package via the following command: sudo dpkg --remove --force-remove-reinstreq zramswap-enabler Step 3. install the package again (sudo apt-get install zramswap-enabler) Step 4. After restart (not necessary) you are able to install the updates correctly! Actually you can fix any "Package is in a very bad inconsistent state” Issues with this solution!!!

    Read the article

  • How to Structure a Trinary state in DB and Application

    - by ABMagil
    How should I structure, in the DB especially, but also in the application, a trinary state? For instance, I have user feedback records which need to be reviewed before they are presented to the general public. This means a feedback reviewer must see the unreviewed feedback, then approve or reject them. I can think of a couple ways to represent this: Two boolean flags: Seen/Unseen and Approved/Rejected. This is the simplest and probably the smallest database solution (presumably boolean fields are simple bits). The downside is that there are really only three states I care about (unseen/approved/rejected) and this creates four states, including one I don't care about (a record which is seen but not approved or rejected is essentially unseen). String column in the DB with constants/enum in application. Using Rating::APPROVED_STATE within the application and letting it equal whatever it wants in the DB. This is a larger column in the db and I'm concerned about doing string comparisons whenever I need these records. Perhaps mitigatable with an index? Single boolean column, but allow nulls. A true is approved, a false is rejected. A null is unseen. Not sure the pros/cons of this solution. What are the rules I should use to guide my choice? I'm already thinking in terms of DB size and the cost of finding records based on state, as well as the readability of code the ends up using this structure.

    Read the article

  • Best approach for tracking dependent state

    - by Pace
    Let's pretend I work on a project tracking application. The application is a database backed, server hosted, web application. In this application there are Projects which have many Activities which have many Tasks. A Task has two date fields an originalDueDate and a projectedDueDate. In addition, there are dynamic fields on the Activities and the Projects which indicate whether the Activity or Project is behind schedule based on the projected due dates of the child tasks and various other variables such as remaining buffer time, etc. There are a number of things that can cause the projectedDueDate to change. For example, an employee working on the project may (via a server request) enter in a shipping delay. Alternatively, a site may (via a server request) enter in an unexpected closure. When any of these things occur I need to not only update the projectedDueDate of the Task but also trigger the corresponding Project and Activity to update as well. What is the best way to do this? I've thought of the observer pattern but I don't keep a single copy of all these objects in memory. When a request comes in, I query the Task in from the database, at that point there is no associated Activity in memory that would be a listener. I could remove the ability to query for Tasks and force the application to query first by Project, then by Activity (in context of Project), then by task (in context of Activity) adding the observer relationships at each step but I'm not sure if that is the best way. I could setup a database event listening system so when a Task modified event is dispatched I have a handler which queries for the Activity at that point. I could simply setup a two-way relationship between Task and Activity so that the Task knows about the parent Activity and when the Task updates his state the Task grabs his parent and updates state. Right now I'm stuck considering all the options and am wondering if any single approach (doesn't have to be a listed approach) is jumping out at others as the best approach.

    Read the article

  • On Developing Web Services with Global State

    - by user74418
    I'm new to web programming. I'm more experienced and comfortable with client-side code. Recently, I've been dabbling in web programming through Python's Google App Engine. I ran into some difficulty while trying to write some simple apps for the purposes of learning, mainly involving how to maintain some kind of consistent universally-accessible state for the application. I tried to write a simple queueing management system, the kind you would expect to be used in a small clinic, or at a cafeteria. Typically, this is done with hardware. You take a number from a ticketing machine, and when your number is displayed or called you approach the counter for service. Alternatively, you could be given a small pager, which will beep or vibrate when it is your turn to receive service. The former is somewhat better in that you have an idea of how many people are still ahead of you in the queue. In this situation, the global state is the last number in queue, which needs to be updated whenever a request is made to the server. I'm not sure how to best to store and maintain this value in a GAE context. The solution I thought of was to keep the value in the Datastore, attempt to query it during a ticket request, update the value, and then re-store it with put. My problem is that I haven't figured out how to lock the resource so that other requests do not check the value while it is in the middle of being updated. I am concerned that I may end up ticket requests that have the same queue number. Also, the whole solution feels awkward to me. I was wondering if there was a more natural way to accomplish this without having to go through the Datastore. Can anyone with more experience in this domain provide some advice on how to approach the design of the above application?

    Read the article

  • Saving a list of items in Application State ASP.NET MVC ?

    - by Calibre2010
    Hi Guys, I'm having a bit of trouble with knowing how I can save items from a list I have in Application state in the global.asax as- Application[""]. My controller basically takes in some user input, I then pass this to another classes Method as parameters it gets added to a list all the time. This data thats getting added to the list I want to store it, but without using a db. By using Application State. . I have been instantiating this class and calling its method to return the list of items but I dont think Application State is saving it. Here is what I have so far. . protected void Application_Start() { RegisterRoutes(RouteTable.Routes); TimeLineInformation t = new TimeLineInformation(); IList<SWTimeEnvInfoDTO> g = t.getInfo(); Application["AppID"] = g; } ^ Global.asax IList<SWTimeEnvInfoDTO> result = new List<SWTimeEnvInfoDTO>(); public void returnTimeLineInfo(string SWrelease, string EnvName, DateTime SDate, DateTime EDate) { SWTimeEnvInfoDTO myDTO = new SWTimeEnvInfoDTO(); myDTO.softwareReleaseName = SWrelease; myDTO.environmentName = EnvName; myDTO.StartDate = SDate; myDTO.EndDate = EDate; result.Add(myDTO); getInfo(); } public IList<SWTimeEnvInfoDTO> getInfo() { return result; } ^ class im calling The SWTimeEnvInfoDTO type has get and set methods for the data. I am calling the application from a View as well. It works with a string Application["AppID"] = "fgt"; and shows this once i read it from my view.

    Read the article

  • How to let hard drive sleep in RAID1 configuration?

    - by Al Kepp
    Normally in Windows 7 a hard drive stops spinning when it is not used for a longer while. This can be configured in Windows and I use it on computers which are turned on 24/7 but not used much often. My problem is on a computer with Intel X79 chipset with an integrated RAID controller. There is Windows 7 installed on an SSD drive, and there is RAID1 array with two SATA HDD drives for data. Those SATA drives aren't used much so I'd like to let them sleep (i.e stop spinning). But they ignore settings in Windows. How to let them sleep when using RAID1? It seems to me that those drives are "unstoppable", they are spinning 24/7 even when they aren't used at all. Maybe they would behave normally if I used Windows-based software RAID, but I use hardware RAID controller. Is there a way to let them stop spinning and sleep after for example 3 or 5 hours of inactivity (i.e. the same way as they would behave in Windows without RAID)?

    Read the article

  • How do I remove a USB drive's write protection?

    - by nate
    I have a SanDisk Cruser Blade USB stick that suddenly seems to be write protected. I tried running DiskPart but after I write the command "attributes disk clear readonly" it displays this: Microsoft DiskPart version 5.1.3565 ADD - Add a mirror to a simple volume. ACTIVE - Marks the current basic partition as an active boot partition. ASSIGN - Assign a drive letter or mount point to the selected volume. BREAK - Break a mirror set. CLEAN - Clear the configuration information, or all information, off the disk. CONVERT - Converts between different disk formats. CREATE - Create a volume or partition. DELETE - Delete an object. DETAIL - Provide details about an object. EXIT - Exit DiskPart EXTEND - Extend a volume. HELP - Prints a list of commands. IMPORT - Imports a disk group. LIST - Prints out a list of objects. INACTIVE - Marks the current basic partition as an inactive partition. ONLINE - Online a disk that is currently marked as offline. REM - Does nothing. Used to comment scripts. REMOVE - Remove a drive letter or mount point assignment. REPAIR - Repair a RAID-5 volume. RESCAN - Rescan the computer looking for disks and volumes. RETAIN - Place a retainer partition under a simple volume. SELECT - Move the focus to an object. It's like when you type help at the DiskPart prompt, so how do I get past this? This problem started when I plugged the stick into a laptop which had viruses, if that's any help.

    Read the article

  • How can I write directly to my Zune HD hard drive?

    - by iamgoat
    When syncing photos to the Zune HD it resizes them down to a much lower resolution which means I cannot load a high res picture on it (comic book) and zoom in to read it. This defeats the whole purpose of having a zoom feature. There is a registry hack you can make to get the Zune to display under My Computer. Then if you killed the zune process while it's syncing you'd be able to access it like a hard drive and copy files to it. It seems like the more recent firmware and/or Zune software version now prevents this. How can I treat it like an HDD and copy files to it? I simply want to take my original pictures folder and copy it over the low resolution versions the Zune software resized it to. An alternative option would be to remove the hard drive from it and see if I can connect it to a computer directly, but I just got this and don't want to disassemble it yet. Note to Microsoft: Why do you allow me to set the encoding quality of music, but not photos?

    Read the article

  • Can a folder on a NAS be made available as a physical drive in VMWare?

    - by asbjornu
    We are currently in the process of moving from a single web server to two load balanced web servers and are facing some challenges we don't quite know how to fix. One of these is that the current single server hosts applications that write stuff to disk. The applications running on the server expects that when something is written to disk it later will in fact exist, so it's important that this premise is fulfilled with the dual server architecture as well. The dual server setup is a couple of VMWare instances with Windows Server 2008 R2 as the guest operating system. Out of the box, these instances does not share any kind of file system, so just moving the applications over would make them break since one instance would write something to the file system that doesn't exist on the other. Thus we need to share a file system between the two virtual servers. Our host has proposed to create a network share on a SAN and map this share individually on each virtual machine. This doesn't work too well due to NTFS permissions, etc., because the share needs to be accessed by several independent web applications that won't even be in the same application pool. The only solution that kind of works is to hard code an "identity" for each web application into its web.config file, but this means password in clear text which doesn't sit well with me. Since the servers are virtual, I'm thinknig: Wouldn't it be possible to make a NAS area available as a physical disk in the gues operating system somehow? Since VMWare has full control of the virtual hardware, you'd think it would be able to "fake" a local hard drive in the virtual machine that in reality is a folder on a NAS, but so far I haven't found anything that states how and if this is possible. So I have to ask the wonderful Server Fault community: Can a folder on a NAS be made available as a physical drive (typical D:) in both of the virtual machines?

    Read the article

  • How can I wipe my iPod classic and fix any bad sectors on the hard drive without killing it?

    - by Sam Meldrum
    My iPod never finishes syncing and only syncs audio, not pictures or video. Any ideas as to how I can fix it? My iPod classic 160GB worked well for a couple of years. I used to sync a lot of photos at full resolution to it, but this recently stopped working after I moved to Windows 7. iTunes is on latest version - 9.1.1.12 iPod software is up to date - 1.1.2 Windows 7 is fully up to date and patched The symptoms are that the iPod will start to sync, all audio (music and podcasts will sync successfully) but the syncing will then just appear to continue - itunes message: Syncing iPod. Do not Disconnect. This sync never completes - I have left it trying for days. I have tried resetting the iPod using the Restore button, whereupon it restarts sync from default options and again will sync audio, but nothing else. I suspect that something has gone wrong on the hard-drive - either a bad sector or some corrupt data. Is there a process I can go through to fix this? E.g. SpinRite or a format? If so how do I go about formatting an iPod and will it be recognised as an iPod after format and work as normal? Any advice on what to try next much appreciated? Update I have eliminated problems with the files, PC or iTunes as they sync fine to other iPods. I have also eliminated the cable by trying different cables which work with other iPods. What I'd really like to know is if there is any way to more fundamentally wipe the iPod safely, attempt to repair any bad sectors on the hard drive and then start from scratch. Anyone ever managed this?

    Read the article

  • how can i move ext3 partition to the beginning of drive without losing data?

    - by Felipe Alvarez
    I have a 500GB external drive. It had two partitions, each around 250GB. I removed the first partition. I'd like to move the 2nd to the left, so it consumes 100% of the drive. How can this be accomplished without any GUI tools (CLI only)? fdisk Disk /dev/sdd: 500.1 GB, 500107862016 bytes 255 heads, 63 sectors/track, 60801 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Disk identifier: 0xc80b1f3d Device Boot Start End Blocks Id System /dev/sdd2 29374 60801 252445410 83 Linux parted Model: ST350032 0AS (scsi) Disk /dev/sdd: 500GB Sector size (logical/physical): 512B/512B Partition Table: msdos Number Start End Size Type File system Flags 2 242GB 500GB 259GB primary ext3 type=83 dumpe2fs Filesystem volume name: extstar Last mounted on: <not available> Filesystem UUID: f0b1d2bc-08b8-4f6e-b1c6-c529024a777d Filesystem magic number: 0xEF53 Filesystem revision #: 1 (dynamic) Filesystem features: has_journal dir_index filetype needs_recovery sparse_super large_file Filesystem flags: signed_directory_hash Default mount options: (none) Filesystem state: clean Errors behavior: Continue Filesystem OS type: Linux Inode count: 15808608 Block count: 63111168 Reserved block count: 0 Free blocks: 2449985 Free inodes: 15799302 First block: 0 Block size: 4096 Fragment size: 4096 Blocks per group: 32768 Fragments per group: 32768 Inodes per group: 8208 Inode blocks per group: 513 Filesystem created: Mon Feb 15 08:07:01 2010 Last mount time: Fri May 21 19:31:30 2010 Last write time: Fri May 21 19:31:30 2010 Mount count: 5 Maximum mount count: 29 Last checked: Mon May 17 14:52:47 2010 Check interval: 15552000 (6 months) Next check after: Sat Nov 13 14:52:47 2010 Reserved blocks uid: 0 (user root) Reserved blocks gid: 0 (group root) First inode: 11 Inode size: 256 Required extra isize: 28 Desired extra isize: 28 Journal inode: 8 Default directory hash: half_md4 Directory Hash Seed: d0363517-c095-4f53-baa7-7428c02fbfc6 Journal backup: inode blocks Journal size: 128M

    Read the article

  • Win 7 crashes, PC reboots and says "Hard drive 0 not found" until I turn if off and on again

    - by Danny T.
    I recently made the move from Windows XP to Windows 7. Since then, when my computer is on for a few hours it always ends up rebooting without warning. Then the BIOS won't recognize my hard drive (hard drive 0 not found). If I turn off my computer and then on again, it boots normally. Some details: Dell Dimension 9150 Windows 7 I updated the BIOS I updated all system drivers with the latest version from Dell (SATA, Chipset, etc.) Other drivers updated too (Graphic card, sound, etc.) There is one thing that I tried after some Googling: I turned off the DMA access to the drives, but it's still rebooting after a few hours. Any clue? UPDATE 2010/12/13 Here are the events from the Event Log for today, from when I turned the computer on until it crashed: 19:17 - Error - ID 10016 - DistributedCom 20:06 - Error - ID 1008 - Customer Improvement Program (could not send data to Microsoft) 21:48 - Critical - ID 41 - Kernel-Power (System was restarted without proper shutdown) 21:48 - Error - ID 6008 - EventLog (Previous system down was not planned) 21:48 - Error - ID 1101 - EventLog (Audit Event ignored) 21:49 - Error - ID 10016 - DistributedCom Both DistributedCom events have a description along these lines (translated from French): The authorisation parameters specific to the application are not allowing Local Execeution for the COM server application with the CLSID {C97FCC79-E628-407D-AE68-A06AD6D8B4D1} and the APPID {344ED43D-D086-4961-86A6-1106F4ACAD9B} to the SID AUTHORITY NT\User System (S-1-5-18) from the address LocalHost (LRPC usage). This security authorisation can be changed with the Component service administration tool. UPDATE 2010/12/31 Here are the error messages I have on blue screens : STOP C000007xA - Kernel_Data_Inpage_Error "Unkown hard error" C00000135 - Can't start because &hs is missing

    Read the article

  • Can a OS be copied from one hard drive to another and still boot?

    - by AlexMorley-Finch
    Background My computer gets stuck on the make and model screen after the BIOS screen, aka the Toshiba screen. After some research I've realized that the problem is the hard drive. I'm using an old 250gb model that USED to be used for backup purposes, however I loaded windows 7 ultimate onto it This hard drive has trouble getting up to full RPM therefore cannot boot correctly until its warmed up. meaning that my pc needs to be restarted several times before it boots (once it took my 13 reboots to get my pc on!) From my research its either that, or lack of power supply, and I've tried multiple PSUs. Question I have my OS and all my files on this 250gb HDD... If I were to literally open the explorer, and copy EVERYTHING (including hidden files obviously) from this 250gb, to a spare 500gb I've got knocking about... Will it boot if I just copy everything? I cannot be bothered to load another OS onto my PC so if there is a way I can just copy the existing one over from one HDD to another and have it boot normally. This would be epic! I've heard about HDD cloning software. But before I purchase and/or download this software, I need to know if i can just copy the OS over through the windows explorer

    Read the article

< Previous Page | 46 47 48 49 50 51 52 53 54 55 56 57  | Next Page >