Search Results

Search found 53332 results on 2134 pages for 'c to vb net'.

Page 52/2134 | < Previous Page | 48 49 50 51 52 53 54 55 56 57 58 59  | Next Page >

  • oRecordset in ASP.NET mySQL problem

    - by StealthRT
    I have this mySQL code that connects to my server. It connects just fine: Dim MyConString As String = "DRIVER={MySQL ODBC 3.51 Driver};" & _ "SERVER=xxx.com;" & _ "DATABASE=xxx;" & _ "UID=xxx;" & _ "PASSWORD=xxx;" & _ "OPTION=3;" Dim conn As OdbcConnection = New OdbcConnection(MyConString) conn.Open() Dim MyCommand As New OdbcCommand MyCommand.Connection = conn MyCommand.CommandText = "select * from userinfo WHERE emailAddress = '" & theUN & "'"" MyCommand.ExecuteNonQuery() conn.Close() However, i have an old Classic ASP page that uses "oRecordset" to get the data from the mySQL server: Set oConnection = Server.CreateObject("ADODB.Connection") Set oRecordset = Server.CreateObject("ADODB.Recordset") oConnection.Open "DRIVER={MySQL ODBC 3.51 Driver}; SERVER=xxx.com; PORT=3306; DATABASE=xxx; USER=xxx; PASSWORD=xxx; OPTION=3;" sqltemp = "select * from userinfo WHERE emailAddress = '" & theUN & "'" oRecordset.Open sqltemp, oConnection,3,3 And i can use oRecordset as follows: if oRecordset.EOF then.... or strValue = oRecordset("Table_Name").value or oRecordset("Table_Name").value = "New Value" oRecordset.update etc... However, for the life of me, i can not find any .net code that is simular to that of my Classic ASP page!!!!! Any help would be great! :o) David

    Read the article

  • Merge Word Documents (Office Interop & .NET), Keeping Formatting

    - by mbmccormick
    I'm having some difficulty merging multiple word documents together using Microsoft Office Interop Assemblies (Office 2007) and ASP.NET 3.5. I'm able to merge the documents, but some of my formatting is missing (namely the fonts and images). My current merge code is shown below. private void CombineDocuments() { object wdPageBreak = 7; object wdStory = 6; object oMissing = System.Reflection.Missing.Value; object oFalse = false; object oTrue = true; string fileDirectory = @"C:\documents\"; Microsoft.Office.Interop.Word.Application WordApp = new Microsoft.Office.Interop.Word.Application(); Microsoft.Office.Interop.Word.Document wDoc = WordApp.Documents.Add(ref oMissing, ref oMissing, ref oMissing, ref oMissing); string[] wordFiles = Directory.GetFiles(fileDirectory, "*.doc"); for (int i = 0; i < wordFiles.Length; i++) { string file = wordFiles[i]; wDoc.Application.Selection.Range.InsertFile(file, ref oMissing, ref oMissing, ref oMissing, ref oFalse); wDoc.Application.Selection.Range.InsertBreak(ref wdPageBreak); wDoc.Application.Selection.EndKey(ref wdStory, ref oMissing); } string combineDocName = Path.Combine(fileDirectory, "Merged Document.doc"); if (File.Exists(combineDocName)) File.Delete(combineDocName); object combineDocNameObj = combineDocName; wDoc.SaveAs(ref combineDocNameObj, ref m_WordDocumentType, ref oMissing, ref oMissing, ref oMissing, ref oMissing, ref oMissing, ref oMissing, ref oMissing, ref oMissing, ref oMissing, ref oMissing, ref oMissing, ref oMissing, ref oMissing, ref oMissing); } I don't care necessarily how this is accomplished. It could output via PDF if it had to. I just want the formatting to carry over. Any help or hints that you could provide me with would be appreciated! Thanks!

    Read the article

  • Using A Local file path in a Streamwriter object ASP.Net

    - by Nick LaMarca
    I am trying to create a csv file of some data. I have wrote a function that successfully does this.... Private Sub CreateCSVFile(ByVal dt As DataTable, ByVal strFilePath As String) Dim sw As New StreamWriter(strFilePath, False) ''# First we will write the headers. ''EDataTable dt = m_dsProducts.Tables[0]; Dim iColCount As Integer = dt.Columns.Count For i As Integer = 0 To iColCount - 1 sw.Write(dt.Columns(i)) If i < iColCount - 1 Then sw.Write(",") End If Next sw.Write(sw.NewLine) ''# Now write all the rows. For Each dr As DataRow In dt.Rows For i As Integer = 0 To iColCount - 1 If Not Convert.IsDBNull(dr(i)) Then sw.Write(dr(i).ToString()) End If If i < iColCount - 1 Then sw.Write(",") End If Next sw.Write(sw.NewLine) Next sw.Close() End Sub The problem is I am not using the streamwriter object correctly for what I trying to accomplish. Since this is an asp.net I need the user to pick a local filepath to put the file on. If I pass any path to this function its gonna try to write it to the directory specified on the server where the code is. I would like this to popup and let the user select a place on their local machine to put the file.... Dim exData As Byte() = File.ReadAllBytes(Server.MapPath(eio)) File.Delete(Server.MapPath(eio)) Response.AddHeader("content-disposition", String.Format("attachment; filename={0}", fn)) Response.ContentType = "application/x-msexcel" Response.BinaryWrite(exData) Response.Flush() Response.End() I am calling the first function in code like this... Dim emplTable As DataTable = SiteAccess.DownloadEmployee_H() CreateCSVFile(emplTable, "C:\\EmplTable.csv") Where I dont want to have specify the file loaction (because this will put the file on the server and not on a client machine) but rather let the user select the location on their client machine. Can someone help me put this together? Thanks in advance.

    Read the article

  • How to implement a download for dynamic files in asp.net with masterpages

    - by Tim
    Hello, the title says it all. I have seen some similar questions on SO like this or this, but either i have overlooked something or my requirement is different, neither works. My situation is following: i have a Masterpage one of its contentpage is called MasterData.aspx MasterData has an asp.net ajax tabcontainer control with one usercontrol in every tabpanel these usercontrols(f.e. MD_Customer.ascx)hold the main content(like a normal page) they all have GridViews in it and i want to provide an Excel-Export-Button What i've tried is is to use an iframe like here. But the function that adds the iframe to the document gets never called and therefore i never see the save-as-dialog. Maybe this is caused by using a MasterPage. Does somebody has an idea on how to provide a button in an UpdatePanel that causes an async postback, so that i can generate a CSV dynamically in codebehind and write it to the response? Thank you in advance. aspx-markup: <asp:UpdatePanel ID="UpdGridInfo" runat="server" > <ContentTemplate> <asp:Label ID="LblInfo" Font-Underline="false" runat="server" CssClass="content" ></asp:Label>&nbsp;&nbsp; <asp:ImageButton ToolTip="export to Excel" style="vertical-align:bottom" ID="BtnExcelExport" ImageUrl="~/images/excel2007logo.png" runat="server" /> </ContentTemplate> </asp:UpdatePanel> and the BtnExportExcel codebehind handler(of course it cannot work to write the csv to the response of this page): Private Sub BtnExcelExport_Click(ByVal sender As Object, ByVal e As System.Web.UI.ImageClickEventArgs) Handles BtnExcelExport.Click Dim csv As String = tableToCsv(DirectCast(Me.GridSource, DataTable)) Response.AddHeader("Content-disposition", "attachment; filename=RuleConfigurationFile.csv") Response.ContentType = "application/octet-stream" Response.Write(csv) Response.End() End Sub

    Read the article

  • How to Loop through LINQ results (VB.NET)

    - by rockinthesixstring
    I've got some code to try and loop through LINQ results, but it doesn't seem to be working. HERE'S THE CODE Public Sub ProcessRequest(ByVal context As System.Web.HttpContext) Implements System.Web.IHttpHandler.ProcessRequest ' the page contenttype is plain text' HttpContext.Current.Response.ContentType = "text/plain" ' store the querystring as a variable' Dim qs As Nullable(Of Integer) = Integer.TryParse(HttpContext.Current.Request.QueryString("ID"), Nothing) ' use the RegionsDataContext' Using RegionDC As New DAL.RegionsDataContext 'create a (q)uery variable' Dim q As Object ' if the querystring PID is not blank' ' then we want to return results based on the PID' If Not qs Is Nothing Then ' that fit within the Parent ID' q = (From r In RegionDC.bt_Regions _ Where r.PID = qs _ Select r.Region).ToArray ' now we loop through the array' ' and write out the ressults' For Each item As DAL.bt_Region In q HttpContext.Current.Response.Write(item.Region & vbCrLf) Next End If End Using End Sub HERE'S THE ERROR Public member 'Region' on type 'String' not found. Description: An unhandled exception occurred during the execution of the current web request. Please review the stack trace for more information about the error and where it originated in the code. Exception Details: System.MissingMemberException: Public member 'Region' on type 'String' not found. Source Error: Line 33: ' and write out the ressults Line 34: For Each item In q Line 35: HttpContext.Current.Response.Write(item.Region & vbCrLf) Line 36: Next Line 37: Source File: E:\Projects\businesstrader\App_Code\Handlers\RegionsAutoComplete.vb Line: 35 Stack Trace: [MissingMemberException: Public member 'Region' on type 'String' not found.] Microsoft.VisualBasic.CompilerServices.Container.GetMembers(String& MemberName, Boolean ReportErrors) +509081 Microsoft.VisualBasic.CompilerServices.NewLateBinding.LateGet(Object Instance, Type Type, String MemberName, Object[] Arguments, String[] ArgumentNames, Type[] TypeArguments, Boolean[] CopyBack) +222 BT.Handlers.RegionsAutoComplete.ProcessRequest(HttpContext context) in E:\Projects\businesstrader\App_Code\Handlers\RegionsAutoComplete.vb:35 System.Web.CallHandlerExecutionStep.System.Web.HttpApplication.IExecutionStep.Execute() +181 System.Web.HttpApplication.ExecuteStep(IExecutionStep step, Boolean& completedSynchronously) +75 Can anyone tell me what I'm doing wrong?

    Read the article

  • Delegate within a delegate in VB.NET.

    - by Topdown
    I am trying to write a VB.NET alternative to a C# anonymous function. I wish to call Threading.SynchronizationContext.Current.Send which expects a delegate of type Threading.SendOrPostCallback to be passed to it. The background is here, but because I wish to both pass in a string to MessageBox.Show and also capture the DialogResult I need to define another delegate within. I am struggling with the VB.NET syntax, both from the traditional delegate style, and lambda functions. My go at the traditional syntax is below, but I have gut feeling it should be much simpler than this: Private Sub CollectMesssageBoxResultFromUserAsDelegate(ByVal messageToShow As String, ByRef wasCanceled As Boolean) wasCanceled = False If Windows.Forms.MessageBox.Show(String.Format("{0}{1}Please press [OK] to ignore this error and continue, or [Cancel] to stop here.", messageToShow), "Continue", Windows.Forms.MessageBoxButtons.OKCancel, Windows.Forms.MessageBoxIcon.Exclamation) = Windows.Forms.DialogResult.Cancel Then wasCanceled = True End If End Sub Private Delegate Sub ShowMessageBox(ByVal messageToShow As String, ByRef canceled As Boolean) Private Sub AskUserWhetherToCancel(ByVal message As String, ByVal args As CancelEventArgs) If args Is Nothing Then args = New System.ComponentModel.CancelEventArgs With {.Cancel = False} Dim wasCancelClicked As Boolean Dim firstDelegate As New ShowMessageBox(AddressOf CollectMesssageBoxResultFromUserAsDelegate) '…. Now what?? 'I can’t declare SendOrPostCallback as below: 'Dim myDelegate As New Threading.SendOrPostCallback(AddressOf firstDelegate) End Sub

    Read the article

  • Dynamic SQL To Dynamic LINQ in VB.NET with MS SQL Server 2008

    - by user337501
    I dread asking this question, because with what I've read so far I understand im gonna have to cram a lotta new things into my head. In spite of all the similiar questions(and the wide variety of answers) I thought I'd ask as nothing I've read tailors to what I need specifically enough. I need to represent the following query using LINQ: DECLARE @PurchasedInventoryItemID Int = 2 DECLARE @PurchasedInventorySectionID Int = 0 DECLARE @PurchasedInventoryItem_PurchasingCategoryID Int = 3 DECLARE @PurchasedInventorySection_PurchasingCategoryID Int = 0 DECLARE @IsActive Bit = 1 DECLARE @PropertyID Int = 2 DECLARE @PropertyValue nvarchar(1000) = 'Granny Smith' --Property1, Property2, Property3 ... SELECT O.PurchasedInventoryObjectID, O.PurchasedInventoryObjectName, O.PurchasedInventoryConjunctionID, O.Summary, O.Count, O.PropertyCount, O.IsActive FROM tblPurchasedInventoryObject As O INNER JOIN tblPurchasedInventoryConjunction As C ON C.PurchasedInventoryConjunctionID = O.PurchasedInventoryConjunctionID INNER JOIN tblPurchasedInventoryItem As I ON I.PurchasedInventoryItemID = C.PurchasedInventoryItemID INNER JOIN tblPurchasedInventorySection As S ON S.PurchasedInventorySectionID = C.PurchasedInventorySectionID INNER JOIN tblPurchasedInventoryPropertyMap as M ON M.PurchasedInventoryObjectID = O.PurchasedInventoryObjectID INNER JOIN tblPropertyValue As V ON V.PropertyValueID = M.PropertyValueID WHERE I.PurchasedInventoryItemID = @PurchasedInventoryItemID AND S.PurchasedInventorySectionID = @PurchasedInventorySectionID AND I.PurchasingCategoryID = @PurchasedInventoryItem_PurchasingCategoryID AND S.PurchasingCategoryID = @PurchasedInventorySection_PurchasingCategoryID AND O.IsActive = @IsActive AND V.PropertyID = @PropertyID AND V.Value = @PropertyValue Now, I know that a query in .NET doesnt look like this, this is my test in the SQL Design Studio. Naturally VB.NET variables will be used in place of the SQL local variables. My problem is this: All of the conditions after "WHERE" are optional. In that a query might be made that uses one, some, all, or none of the conditions. V.PropertyID and V.Value can also appear any number of times. In VB.NET I can make this query easy enough by simply concatenating strings, and using a loop to append the "V.PropertyID/V.Value" conditions. I can also make a Stored Procedure in MS SQL, which is easy enough. However, I want to accomplish this using LINQ. If anyone could direct me, I would be most appreciative.

    Read the article

  • VB.NET - Object reference not set to an instance of an object

    - by Daniel
    I need some help with my program. I get this error when I run my VB.NET program with a custom DayView control. ***** Exception Text ******* System.NullReferenceException: Object reference not set to an instance of an object. at SeaCow.Main.DayView1_ResolveAppointments(Object sender, ResolveAppointmentsEventArgs args) in C:\Users\Daniel\My Programs\Visual Basic\SeaCow\SeaCow\SeaCow\Main.vb:line 120 at Calendar.DayView.OnResolveAppointments(ResolveAppointmentsEventArgs args) at Calendar.DayView.OnPaint(PaintEventArgs e) at System.Windows.Forms.Control.PaintWithErrorHandling(PaintEventArgs e, Int16 layer) at System.Windows.Forms.Control.WmPaint(Message& m) at System.Windows.Forms.Control.WndProc(Message& m) at System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam) According to the error code, the 'for each' loop below is causing the NullReferenceException error. At default, the 'appointments' list is assigned to nothing and I can't find where the ResolveAppointments function is being called at. Private Sub DayView1_ResolveAppointments(ByVal sender As Object, ByVal args As Calendar.ResolveAppointmentsEventArgs) Handles DayView1.ResolveAppointments Dim m_Apps As New List(Of Calendar.Appointment) For Each m_App As Calendar.Appointment In appointments If (m_App.StartDate >= args.StartDate) AndAlso (m_App.StartDate <= args.EndDate) Then m_Apps.Add(m_App) End If Next args.Appointments = m_Apps End Sub Anyone have any suggestions?

    Read the article

  • Deserialize complex JSON (VB.NET)

    - by Ssstefan
    I'm trying to deserialize json returned by some directions API similar to Google Maps API. My JSON is as follows (I'm using VB.NET 2008): jsontext = { "version":0.3, "status":0, "route_summary": { "total_distance":300, "total_time":14, "start_point":"43", "end_point":"42" }, "route_geometry":[[51.025421,18.647631],[51.026131,18.6471],[51.027802,18.645639]], "route_instructions": [["Head northwest on 43",88,0,4,"88 m","NW",334.8],["Continue on 42",212,1,10,"0.2 km","NW",331.1,"C",356.3]] } So far I came up with the following code: Dim js As New System.Web.Script.Serialization.JavaScriptSerializer Dim lstTextAreas As Output_CloudMade() = js.Deserialize(Of Output_CloudMade())(jsontext) I'm not sure how to define complex class, i.e. Output_CloudMade. I'm trying something like: Public Class RouteSummary Private mTotalDist As Long Private mTotalTime As Long Private mStartPoint As String Private mEndPoint As String Public Property TotalDist() As Long Get Return mTotalDist End Get Set(ByVal value As Long) mTotalDist = value End Set End Property Public Property TotalTime() As Long Get Return mTotalTime End Get Set(ByVal value As Long) mTotalTime = value End Set End Property Public Property StartPoint() As String Get Return mStartPoint End Get Set(ByVal value As String) mStartPoint = value End Set End Property Public Property EndPoint() As String Get Return mEndPoint End Get Set(ByVal value As String) mEndPoint = value End Set End Property End Class Public Class Output_CloudMade Private mVersion As Double Private mStatus As Long Private mRSummary As RouteSummary 'Private mRGeometry As RouteGeometry 'Private mRInstructions As RouteInstructions Public Property Version() As Double Get Return mVersion End Get Set(ByVal value As Double) mVersion = value End Set End Property Public Property Status() As Long Get Return mStatus End Get Set(ByVal value As Long) mStatus = value End Set End Property Public Property Summary() As RouteSummary Get Return mRSummary End Get Set(ByVal value As RouteSummary) mRSummary = value End Set End Property 'Public Property Geometry() As String ' Get ' End Get ' Set(ByVal value As String) ' End Set 'End Property 'Public Property Instructions() As String ' Get ' End Get ' Set(ByVal value As String) ' End Set 'End Property End Class but it does not work. The problem is with complex properties, like route_summary. It is filled with "nothing". Other properties, like "status" or "version" are filled properly. Any ideas, how to define class for the above JSON? Can you share some working code for deserializing JSON in VB.NET? Thanks,

    Read the article

  • VB.NET pinvoke declaration wrong?

    - by tmighty
    I copied and pasted the following VB.NET structure from the pinvoke website. http://www.pinvoke.net/default.aspx/Structures/BITMAPINFOHEADER.html However when I paste it into a module under the module name like this, VB.NET is telling me that a declaration is expected: Option Strict Off Option Explicit On Imports System Imports System.Diagnostics Imports System.Drawing Imports System.Drawing.Drawing2D Imports System.Runtime.InteropServices Imports System.Windows.Forms Module modDrawing StructLayout(LayoutKind.Explicit)>Public Structure BITMAPINFOHEADER <FieldOffset(0)> Public biSize As Int32 <FieldOffset(4)> Public biWidth As Int32 <FieldOffset(8)> Public biHeight As Int32 <FieldOffset(12)> Public biPlanes As Int16 <FieldOffset(14)> Public biBitCount As Int16 <FieldOffset(16)> Public biCompression As Int32 <FieldOffset(20)> Public biSizeImage As Int32 <FieldOffset(24)> Public biXPelsperMeter As Int32 <FieldOffset(28)> Public biYPelsPerMeter As Int32 <FieldOffset(32)> Public biClrUsed As Int32 <FieldOffset(36)> Public biClrImportant As Int32 End Structure Where did I go wrong, please? Thank you very much.

    Read the article

  • VB.NET trying simple captcha

    - by Pride Grimm
    I'm trying to write a simple captcha program in vb.net. I'm just wanting to make an image from random numbers and display it, check the answer, and then proceed. I'm pretty new to vb.net, so I found some code to generate the information. I will cite the owner when I find it again (http://www.knowlegezone.com/80/article/Technology/Software/Asp-Net/Simple-ASP-NET-CAPTCHA-Tutorial) This is in the onload() of default2.aspx Public Sub returnNumer() Dim num1 As New Random Dim num2 As New Random Dim numQ1 As Integer Dim numQ2 As Integer Dim QString As String numQ1 = num1.Next(10, 15) numQ2 = num2.Next(17, 31) QString = numQ1.ToString + " + " + numQ2.ToString + " = " Session("answer") = numQ1 + numQ2 Dim bitmap As New Bitmap(85, 35) Dim Grfx As Graphics = Graphics.FromImage(bitmap) Dim font As New Font("Arial", 18, FontStyle.Bold, GraphicsUnit.Pixel) Dim Rect As New Rectangle(0, 0, 100, 50) Grfx.FillRectangle(Brushes.Brown, Rect) Grfx.DrawRectangle(Pens.PeachPuff, Rect) ' Border Grfx.DrawString(QString, font, Brushes.Azure, 0, 0) Response.ContentType = "Image/jpeg" bitmap.Save(Response.OutputStream, System.Drawing.Imaging.ImageFormat.Jpeg) bitmap.Dispose() Grfx.Dispose() End Sub So I put this in a separate page, like this This all works find and dandy, but when I get the answer from the session like this Dim literal As String = Convert.ToString(Session("answer")) It's always one behind. So if The images adds to 32, the answer in session isn't 32. But after a refresh (and a new image) the session("answer") will be 32. Is there a way to refresh the session on page 1, after the default2.aspx loads? Is there a better way to do this? I though about trying to run the code all on one page, and trying to set the src of and image to returnNumber(), but I need a bit of help on that one.

    Read the article

  • VB .NET error handling, pass error to caller

    - by user1375452
    this is my very first project on vb.net and i am now struggling to migrate a vba working add in to a vb.net COM Add-in. I think i'm sort of getting the hang, but error handling has me stymied. This is a test i've been using to understand the try-catch and how to pass exception to caller Public Sub test() Dim ActWkSh As Excel.Worksheet Dim ActRng As Excel.Range Dim ActCll As Excel.Range Dim sVar01 As String Dim iVar01 As Integer Dim sVar02 As String Dim iVar02 As Integer Dim objVar01 As Object ActWkSh = Me.Application.ActiveSheet ActRng = Me.Application.Selection ActCll = Me.Application.ActiveCell iVar01 = iVar02 = 1 sVar01 = CStr(ActCll.Value) sVar02 = CStr(ActCll.Offset(1, 0).Value) Try objVar01 = GetValuesV(sVar01, sVar02) 'DO SOMETHING HERE Catch ex As Exception MsgBox("ERRORE: " + ex.Message) 'LOG ERROR SOMEWHERE Finally MsgBox("DONE!") End Try End Sub Private Function GetValuesV(ByVal QryStr As Object, ByVal qryConn As String) As Object Dim cnn As Object Dim rs As Object Try cnn = CreateObject("ADODB.Connection") cnn.Open(qryConn) rs = CreateObject("ADODB.recordset") rs = cnn.Execute(QryStr) If rs.EOF = False Then GetValuesV = rs.GetRows Else Throw New System.Exception("Query Return Empty Set") End If Catch ex As Exception Throw ex Finally rs.Close() cnn.Close() End Try End Function i'd like to have the error message up to test, but MsgBox("ERRORE: " + ex.Message) pops out something unexpected (Object variable or With block variable not set) What am i doing wrong here?? Thanks D

    Read the article

  • VB.Net - Launch app on Windows startup

    - by Queops
    We all now the tricky folders where your application runs when you publish your VB.NET to other people, but I won't give up on the benefits of the system (auto-update, you know). Problem is: Program is supposed to startup, or not, with Windows if the user wishes so. I'm saving program preferences into My.Settings. All fine with that. If you debug it it will save the values between sessions. The problem is after deployment. I installed the program on a testing machine. Application works okay, the settings load, if it's the user launching it by themselfs (using shortcut on desktop for example). Now upon restarting the program does indeed start up as I want it to but the My.Settings don't show up! It's like the config file has been erased. If I close program and re-open by clicking shorcut it loads the settings just fine though. So I wonder what's the problem? This is the code I use to save the registry key: regKey = Registry.CurrentUser.OpenSubKey("SOFTWARE\Microsoft\Windows\CurrentVersion\Run", True) regKey.SetValue("ScapeTracker", Chr(34) & Application.ExecutablePath & Chr(34) & " startup") Does what it's supposed to. The startup parameter is needed so the program knows if it's launched on startup on not (to show up on tray and idle there until user decides to use it). So the problem is that I can't use the settings upon restart of Windows, so I'm assuming the VB.Net applications have some extra parameters when launching? How can I solve this?

    Read the article

  • Do I need to compile my solution with VS2010 in order to benefit from .NET 4.0 new Code Access Secur

    - by leo
    Hello, I currently develop an application in C# with framework .NET 3.5 SP1. In my app, I have satellite assemblies which are not in the same folder as the exe, and that causes me some trouble with FullTrust, as explained here. In order to solve that problem, I wish to use .NET 4.0 whose Code Access Security Policy should allow my satellite assemblies to be FullyTrusted. So my question is: is just installing the framework enough, or do I need to rebuild the solution with VS2010? Thanks

    Read the article

  • What is the equivalent of ASP:Timer control in ASP.NET MVC?

    - by Rupa
    Hi Recently i am working on migrating the ASP.NET Web application to MVC. I am wondering if there is any equivalent of ASP:Timer control in ASP.NET MVC Framework. So that this Timer control can automatically check for a particular value from the Database once in every couple of Seconds(that we specify). If there is no equivalent of Timer control in MVC, Are there any other ways to implement this. Appreciate your responses. Thanks

    Read the article

  • Am I Leaking ADO.NET Connections?

    - by HardCode
    Here is an example of my code in a DAL. All calls to the database's Stored Procedures are structured this way, and there is no in-line SQL. Friend Shared Function Save(ByVal s As MyClass) As Boolean Dim cn As SqlClient.SqlConnection = Dal.Connections.MyAppConnection Dim cmd As New SqlClient.SqlCommand Try cmd.Connection = cn cmd.CommandType = CommandType.StoredProcedure cmd.CommandText = "proc_save_my_class" cmd.Parameters.AddWithValue("@param1", s.Foo) cmd.Parameters.AddWithValue("@param2", s.Bar) Return True Finally Dal.Utility.CleanupAdoObjects(cmd, cn) End Try End Function Here is the Connection factory (if I am using the correct term): Friend Shared Function MyAppConnection() As SqlClient.SqlConnection Dim cn As New SqlClient.SqlConnection(ConfigurationManager.ConnectionStrings("MyConnectionString").ToString) cn.Open() If cn.State <> ConnectionState.Open Then ' CriticalException is a custom object inheriting from Exception. Throw New CriticalException("Could not connect to the database.") Else Return cn End If End Function Here is the Dal.Utility.CleaupAdoObjects() function: Friend Shared Sub CleanupAdoObjects(ByVal cmd As SqlCommand, ByVal cn As SqlConnection) If cmd IsNot Nothing Then cmd.Dispose() If cn IsNot Nothing AndAlso cn.State <> ConnectionState.Closed Then cn.Close() End Sub I am getting a lot of "Timeout expired. The timeout period elapsed prior to completion of the operation or the server is not responding." error messages reported by the users. The application's DAL opens a connection, reads or saves data, and closes it. No connections are ever left open - intentionally! There is nothing obvious on the Windows 2000 Server hosting the SQL Server 2000 that would indicate a problem. Nothing in the Event Logs and nothing in the SQL Server logs. The timeouts happen randomly - I cannot reproduce. It happens early in the day with only 1 to 5 users in the system. It also happens with around 50 users in the system. The most connections to SQL Server via Performance Monitor, for all databases, has been about 74. The timeouts happen in code that both saves to, and reads from, the database in different parts of the application. The stack trace does not point to one or two offending DAL functions. It's happened in many different places. Does my ADO.NET code appear to be able to leak connections? I've goolged around a bit, and I've read that if the connection pool fills up, this can happen. However, I'm not explicitly setting any connection pooling. I've even tried to increase the Connection Timeout in the connection string, but timeouts happen long before the 300 second (5 minute) value: <add name="MyConnectionString" connectionString="Data Source=MyServer;Initial Catalog=MyDatabase;Integrated Security=SSPI;Connection Timeout=300;"/> I'm at a total loss already as to what is causing these Timeout issues. Any ideas are appreciated.

    Read the article

  • What to choose.... web service or WCF in asp.net 3.5

    - by HotTester
    The current project i am working on is extensively using web services and is made in .net 3.5. Now as we are going for implementation of second phase we are confused if we should either use WCF or web service as done previously ? Further is there anything new that can be useful and is coming up with .net 4.0 regarding web services or WCF. Thanks in advance. A good link for this is here.

    Read the article

  • Oi! What's going on with the .NET Reflector update mechanism?

    - by Bart Read
    Anyone who's been using .NET Reflector for any length of time will by now be used to its built-in update mechanism. Every 6 months or so it will ask you to upgrade to the latest version and, if you don't, will refuse to work after a few weeks have passed. Love it or hate it, it mostly works pretty well, unless your internet connection is down, in which case it can be a pain in the ass (we're discussing options to improve this situation at the moment because, if you haven't fired it up for a while,...(read more)

    Read the article

  • VSTO Development - Key Improvements In VS2010 / .NET 4.0?

    - by dferraro
    Hi all, I am trying to make a case to my bosses on why we should use VS2010 for an upcoming Excel Workbook VSTO application. I haven't used VSTO before but have used VBA. With 2010 just around the corner, I wanted to read about the improvements made to see if it was worth using 2010 to develop this application. So far I have read 2 major improvements are ease of deployments and also debugging / com interop improvements ... I was just wondering if there was anything else I wasn't aware of, or if anyone here is actually developing in VSTO and has used 2010 and both 2008 and could help make a case / arm me with information. The main concern of my bosses is deploying .NET 4.0 runtime on the Citrix servers here... however it seems that with 3.5, we would have to deploy the VSTO runtime and PIA's, etc... So really wouldn't deployments be easier with 2010 because installing just the 4.0 runtime is better than having to install the 'VSTO Runtime' as well as PIA's, etc? Or is there something I'm missing here? Anyone here deploy VSTO app in an enterprise and can speak to this? Also - I'm trying to also fight to use C# over VB.NET for this app. Does anyone know any key reasons why (except for my bias on preference of syntax) it would be better to use C# over VB for this? Any key features lacking in VB VSTO development? I've read about the VSTO Power Tools, and one of them describes LINQ enalbment of the Excel Object Model classes - however it says 'a set of C# classes'... Does anyone know if they literally mean C# - so this would not work with VB.NET, or do they just mean the code is written in C#? Anyone ever used these power tools with VB? I am going to download & play with it now, but any help again is greatly appreciated Thanks very much for any information.

    Read the article

  • Want to bind querystring in postbackurl of imagebutton in gridview?

    - by Sikender
    Hi ,when i try to databind the '<%#Eval("EntryID") %>' to the ImageButton's postbackurl as <asp:ImageButton ID="ibtnEdit" runat="server" CommandName="Edit" CommandArgument='<%#DataBinder.Eval(Container.DataItem,"SystemEmailID")%>' ImageUrl="~/Images/edit-list.gif" PostBackUrl="~/Edit_SyatemEmails.aspx?blogentry=edit&id=<%#DataBinder.Eval(Container.DataItem,"SystemEmailID")%>"/> it's failed, then i updated the code to <asp:ImageButton ID="ibtnBlogEntryEdit" PostBackUrl='"~/admin/BlogEntry.aspx?blogentry=edit&entryid=" & <%# Eval("EntryID") %>' SkinID="edit" runat="server" /> well,the above code has pass the debugging,but failed to databind to the postbackurl,the result as http://localhost/dovoshow/"~/admin/BlogEntry.aspx?blogentry=edit&entryid="%20&%20<%#%20Eval("EntryID")%20%> so,anyonw know how to solve it ,help me thanks

    Read the article

  • "Randomly" occurring errors...

    - by ClarkeyBoy
    Hi, My website has a setup whereby when the application starts a module called SiteContent is "created". This runs a clearup function which basically deletes any irrelevant data from the database, in case any has been left in there from previously run functions. The module has instances of Manager classes - namely RangeManager, CollectionManager, DesignManager. There are others but I will just use these as an example. Each Manager class contains an array of items - items may be of type Range, Collection or Design, whichever one is relevant. Data for each range is then read into an instance of Range, Collection or Design. I know this is basically duplicating data - not very efficient but its my final year project at the moment so I can always change it to use Linq or something similar later, when I am not pressured by the one month deadline. I have a form which, on clicking the Save button, saves data by calling SiteContent.RangeManager.Create(vars) or SiteContent.RangeManager.Update(Range As Range, vars) (or the equivalent for other manager classes, whichever one happens to be relevant). These functions call a stored procedure to insert or update in the relevant table. Classes Range, Collection and Design all have attributes such as Name, Description, Display and several others. When the Create or Update function is called, the Manager loops through all the other items to check if an item with the same name already exists. The Update function ensures that it does not compare the item being updated to itself. A custom exception (ItemAlreadyExistsException) is thrown if another item with the same name is found. For some weird reason, if I go into a Range, Collection or Design in edit mode, change something and try to update it, it occasionally doesnt update the item. When I say occasionally I mean every 3 - 4 page loads, sometimes more. I see absolutely no pattern in when or why it occurs. I have a try-catch statement which catches ItemAlreadyExistsException, and outputs "An item with this name already exists" when caught. Occasionally it will output this; other times it will not. Does anyone have any idea why this could happen? Maybe a mistake which someone has made and solved before? I used to have regular expressions in place that the names were compared to - I believe it was [a-zA-Z]{1, 100} (between 1 and 100 lower- or upper-case characters). For some reason the customer who I am developing the site for used to get errors saying its not in the correct format. Yet he could try the same text 5 minutes later and it would work fine. I am thinking this could well be the same problem, since both problems occur at random. Many thanks in advance. Regards, Richard Clarke Edit: After much time spent narrowing down the code, I have decided to wait till my brother, who has been a programmer for at least 8 years more than I have, to come down over Easter and get him to have a look at it. If he cant solve it then I will zip the files up and put them somewhere for people to access and have a go at. I narrowed it down literally to the minimum number of files possible, and it still occurs. It seems to be about every 10th time. Having said that, I force the manager classes to refresh every 10 page loads or 5 minutes (whichever one is sooner). I may look into this - this could be causing a problem. Basically each Manager contains an array of an object. This array is populated using data from the database. The Update function takes an instance of the item and the new values to be set for the object. If it happens to be a page load where the array is reset (ie the data is loaded freshly from the database) then the object instance with the same ID wont be the same instance as the one being passed in. This explains the fact that it throws an ItemAlreadyExistsException now and then. It all makes sense now the more I think about it. If I were to pass in the ID of the object to be altered, rather than the object itself, then it should work perfectly. I will answer the question if I solve it..

    Read the article

  • Show alert message box from the Global.asax (on Application_Error event)

    - by Albert
    Normally I just redirect to a custom error page in on the Application_Error event, but I have a specific error for which I'd like to display an alert message while the user is still on the page which triggers the error. How can I make this happen? I'm open to a modalpopup or any other type of error message, I just want to ensure the user stays on the page where they encounter the error. Thank for any ideas.

    Read the article

  • HttpRequest.BeginWebRequest not executing asynchronously

    - by Shawn Simon
    I have the following code: Private Function CreateRequest() As HttpWebRequest Dim request As HttpWebRequest = HttpWebRequest.Create(_url) request.Method = "POST" request.ContentType = "application/x-www-form-urlencoded" Dim postData As String = String.Join("&", GetPostData().Select(Function(s) String.Format("{0}={1}", s.Key, HttpUtility.UrlEncode(s.Value))).ToArray) Dim data As Byte() = (New ASCIIEncoding).GetBytes(postData) request.Timeout = _maxTimeoutSeconds * 1000 Dim stream = request.GetRequestStream stream.Write(data, 0, data.Length) stream.Close() Return request End Function Public Sub SendAsync(ByVal callback As Action(Of ResponseBase)) Dim request = CreateRequest() _attemptCount += 1 Dim reqID As Integer If _loggingContext IsNot Nothing Then Try reqID = Log.NotesRequest(_url.ToString, GetPostData, _loggingContext) Catch ex As Exception ErrorTracker.LogError(ex) End Try End If Dim responseState As New ResponseState responseState.LoggedNotesRequestID = reqID responseState.Request = request responseState.Callback = callback Dim response = request.BeginGetResponse(New AsyncCallback(AddressOf RespCallback), responseState) End Sub Private Sub RespCallback(ByVal ar As IAsyncResult) Dim responseState As ResponseState = CType(ar.AsyncState, ResponseState) ' Process response... I set up the request to go to a mock server which sleeps for 30 seconds. When I call BeginGetResponse, the application just waits at that line of code for the response. I want it to carry on with the app, and then just run the callback whenever it finishes. This code is run from a web page, and my callback just logs the response and sends an email. I don't want to use to have to wait for the response.

    Read the article

  • can't get data from database to dropdownlist in loginview

    - by Thomas Bøg Petersen
    I have this code on an aspx page. <asp:DropDownList runat="server" ID="ddlSize" CssClass="textbox" Width="100px"> <asp:ListItem Value="" Text="" /> <asp:ListItem Value="11" Text="11. Mands" /> <asp:ListItem Value="7" Text="7. Mands" /> <asp:ListItem Value="" Text="Ikke Kamp"/> </asp:DropDownList> <asp:DropDownList runat="server" ID="ddlType" CssClass="textbox" Width="100px"> <asp:ListItem Value="" Text="" /> <asp:ListItem Value="K" Text="Kamp" /> <asp:ListItem Value="T" Text="Træning" /> <asp:ListItem Value="E" Text="Aktivitet"/> </asp:DropDownList> ts inside a loginview with some other fields (textbox) Im trying to get a record id into the page so i can edit it, I have fix it with the Textbox and its working 100%, but i cant get the value from the database into the dropdownlist so it show that value as selected. I have tryed these 3 codes, but nothing is working fore the dropdownlist. // DataValueField Dim drop_obj As DropDownList = TryCast(LoginView2.FindControl("ddlSize"), DropDownList) drop_obj.DataValueField = dtEvents.Rows(0)("EventEventSize") Dim drop_obj2 As DropDownList = TryCast(LoginView2.FindControl("ddlType"), DropDownList) drop_obj2.DataValueField = dtEvents.Rows(0)("EventType") // SelectedIndex Dim drop_obj As DropDownList = TryCast(LoginView2.FindControl("ddlSize"), DropDownList) drop_obj.SelectedIndex = dtEvents.Rows(0)("EventEventSize") Dim drop_obj2 As DropDownList = TryCast(LoginView2.FindControl("ddlType"), DropDownList) drop_obj2.SelectedIndex = dtEvents.Rows(0)("EventType") // SelectedValue Dim drop_obj As DropDownList = TryCast(LoginView2.FindControl("ddlSize"), DropDownList) drop_obj.SelectedValue = dtEvents.Rows(0)("EventEventSize") Dim drop_obj2 As DropDownList = TryCast(LoginView2.FindControl("ddlType"), DropDownList) drop_obj2.SelectedValue = dtEvents.Rows(0)("EventType") Can someone plz. help !? I have values in the 2 dtEvents.Rows(0) i have checked that, with a debug and then step-into. and i get values like 7 or 11 and T or K.

    Read the article

< Previous Page | 48 49 50 51 52 53 54 55 56 57 58 59  | Next Page >