  • Laptop will not boot

    - by WillumMaguire
    This is a dell studio 1558 laptop. Now, something is wrong with the charger that it won't charge the laptop, but the laptop can turn on and operate properly as long as it is attached. It has been like this for a while, but it's not the problem. My problem is that as of yesterday, It takes several minutes to get past the "dell" startup logo (where is says "f2 setup" and "f12 boot options"). After it gets past, it beeps as normal to tell me about the charger and gives me the f2/f12 options and f1 to continue as normal. I can press f12 to get into boot options and load into my live USB BackTrack 5 ISO, but after "startx" it just stays at a black screen. I can also access BIOS setup, but see nothing that would help the problem. When I boot to the HDD, it gives me this Intel UNDI, PXE-2.1 (build 083) Realktek PCIe GBE Family Controller Series V.2.29 (06/30/09) PXE-E61: Media test failure, check cable PXE-M0F: Exiting PXE ROM Operating System not found Also, pressing f8 gives me the same results as booting as normal. It is running Windows 7 Ultimate, dual-core Intel i3 @ 2.27ghz and 4gb RAM. I think there is an issue with the HDD, as the "Operating System not found" would lead me to believe. Is this a fixable problem?

    Read the article

  • VNC error: "Could not connect to session bus: Failed to connect to socket"

    - by GJ
    I started a vncserver on display :1 on an ubuntu machine. When I connect to it, I get a grey X window with an error message Could not connect to session bus: Failed to connect to socket. The vnc log is: Xvnc Free Edition 4.1.1 - built Apr 9 2010 15:59:33 Copyright (C) 2002-2005 RealVNC Ltd. See http://www.realvnc.com for information on VNC. Underlying X server release 40300000, The XFree86 Project, Inc Sun Mar 20 15:33:59 2011 vncext: VNC extension running! vncext: Listening for VNC connections on port 5901 vncext: created VNC server for screen 0 error opening security policy file /etc/X11/xserver/SecurityPolicy Could not init font path element /usr/X11R6/lib/X11/fonts/Type1/, removing from list! Could not init font path element /usr/X11R6/lib/X11/fonts/Speedo/, removing from list! Could not init font path element /usr/X11R6/lib/X11/fonts/misc/, removing from list! Could not init font path element /usr/X11R6/lib/X11/fonts/75dpi/, removing from list! Could not init font path element /usr/X11R6/lib/X11/fonts/100dpi/, removing from list! cat: /var/run/gdm/auth-for-link2-eGnVvf/database: No such file or directory gnome-session[24880]: WARNING: Could not make bus activated clients aware of DISPLAY=:1.0 environment variable: Failed to connect to socket /tmp/dbus-FhdHHIq8jt: Connection refused gnome-session[24880]: WARNING: Could not make bus activated clients aware of GNOME_DESKTOP_SESSION_ID=this-is-deprecated environment variable: Failed to connect to socket /tmp/dbus-FhdHHIq8jt: Connection refused gnome-session[24880]: WARNING: Could not make bus activated clients aware of SESSION_MANAGER=local/dell:@/tmp/.ICE-unix/24880,unix/dell:/tmp/.ICE-unix/24880 environment variable: Failed to connect to socket /tmp/dbus-FhdHHIq8jt: Connection refused Sun Mar 20 15:34:10 2011 Connections: accepted: 0.0.0.0::51620 SConnection: Client needs protocol version 3.8 SConnection: Client requests security type VncAuth(2) VNCSConnST: Server default pixel format depth 16 (16bpp) little-endian rgb565 VNCSConnST: Client pixel format depth 16 (16bpp) little-endian rgb565 gnome-session[24880]: Gtk-CRITICAL: gtk_main_quit: assertion `main_loops != NULL' failed gnome-session[24880]: CRITICAL: dbus_g_proxy_new_for_name: assertion `connection != NULL' failed Any ideas how to fix it?

    Read the article

  • Explorer.EXE ordinal 423 not found in urlmon.dll after updates/IE8 install

    - by Zoot
    Setting up a brand new Dell Optiplex 980 with Windows XP SP3, and everything started up fine on the first boot. My first task was to install system updates, including IE8 and WGA. After the required reboot after installing updates, I now get this error message: Explorer.EXE Ordinal not found. The ordinal 423 could not be located in the dynamic link library urlmon.dll Per my cursory Google search, this forum thread places the blame squarely on IE8. The solution provided is to enter safe mode and remove IE8. Unfortunately, when I press F8 to choose to boot safe mode, I only have the option of "Windows XP SP3 Professional" and no safe mode options. Any other ideas? Thanks in advance. FYI, I can get to the Windows Task Manager by holding down Control-Alt-Delete, but programs don't seem to run properly if you select them. I tried chatting with Dell Support, and we tried to initiate the system restore at c:\windows\system32\restore\rstrui.exe, but that had a similar "ordinal 423 not found in urlmon.dll" error.

    Read the article

  • Windows Bluescreen - atikmpag.sys

    - by Mochan
    Information Name: atikmpag.sys bluescreen (BSOD or BlueScreen of Death) Error code: 0x00000116 Appears when: Playing games, watching videos Can be reproduced: Yes Cause: Graphics Card is the main assumption System Specifications Before we begin - I will inform you of my specifications. OS: Windows 7 x64 Home Edition Model: Dell Inspiron 15R Special Edition (aka Inspiron 7520) (Add 2GB of RAM to the model linked) Hard Drive: 1TB CPU: Intel Quad-Core i7 Sandy Bridge (I think) Processor at 2.10GHz (I think it can be clocked to 3GHz?) RAM: 6GB (I think 1 x 4GB and 1 x 2GB) Display: 15.6" HD (1366x768) Graphics: AMD Radeon HD 7500M 2GB Details So now that you know some basics about my computer, I'll get to the problem. Being an Ubuntu user I hardly use Windows, but occasionally I do. Like to run Skyrim and other games incompatible with Linux and WINE. The new Sims 3 Seasons patch is also now not supported. When playing these two games and other ones, theoretically. I have also heard others saying that while watching HD movies and video series it also happens. While watching the bluescreen as it happens, I see it is the 'atikmpag.sys' error. I have not installed much and nothing significant. I think I have downloaded Skyrim, Firefox and The Sims 3. I haven't done much more... since Ubuntu is definitely the best in comparison! (No hate, just a joke :P). I can reproduce it easily (just by running a game for less than a minute). It is always there each time, but it's never at a specific time or anything. So far I have found that it may be caused by lack of power to the graphics card, or it may be damaged or fried. Since I've had the computer for a mere 4 months (and have had other problems with it also). I have contacted Dell but they are useless beyond belief. Anyone with any information, solutions or details are encouraged to share your knowledge, as it would be immensely appreciated.

    Read the article

  • Windows Server 2003 DC hangs after network drivers update

    - by tcv
    Earlier today, we attempted to update the Broadcom BCM5716C network drivers on a Windows Server 2003. (Dell PowerEdge T310, FWIW). Since then we have not been able to boot the server in any normal mode. Safe Mode works. Safe Mode with Networking and regular bootups hang at "Applying Network Settings." I haven't tried Last Known Good Configuration nor have I tried Directory Services Restore Mode. I should also mention that the longest I've allowed "Applying Network Settings" was perhaps 30 minutes. I spoke to Dell since the server is under a basic warranty. They sent me the original Broadcom drivers. The trouble seems to be, however, that since I can only boot in Safe Mode, I can't install the application package as given. In safe mode, I receive the error: "The system administrator has set policies to prohibit this installation." I can install the drivers independently, but that doesn't allow the NICs to work. The most I've been able to get are Code 10 errors on each NIC. I plan to get back to the site tomorrow to attempt installation of a different NIC. I'm wondering what else I can try.

    Read the article

  • Backup hardware and strategy on distributed Windows Server 2008 network

    - by CesarGon
    This question is a follow up to this. We have a Windows Server 2008 R2 domain over a network that spans two different buildings, linked by a 100-Mbps point-to-point line. Over 60 users work in the organisation. We are planning to use DFS folders and DFS replication for file serving across the organisation. The estimated data volume is over 2 TB, and will grow at approximately 20% annually. The idea is to set up a DFS file server in each building and use DFS so that all the contents stay replicated over the 100-Mbps link. We are now considering backup hardware and strategies. We are Dell customers and, after browsing the online Dell catalogue, I can see a number of backup hardware options. My main doubts are the following: Would you go for a tape library, disk backup, or are there other options worth considering? Would you perform batch backups (i.e. nightly) or would you use continuous backup (i.e. while users are working)? Would you use a dedicated backup server to which the tape library (or any other backup device) is attached, or is there any other alternative way of doing things? My experience with backup hardware and overall setup is limited, so I appreciate any good piece of advice that you may have. Thanks.

    Read the article

  • Problems with synaptic touchpad

    - by penlite
    The "enhanced" features of the synaptics touchpad (ie scroll, pinch zoom) on my windows 7 64 bit dell studio 17 only work intermittently. This was an issue with the original OEM driver and also with the new driver from synaptics - please do not suggest that i update, reinstall, install as administrator, check or jiggle the driver - if i hear that one more time i will freak out. I have researched this for days and appears to be a common problem without a solution (many suggestions to update the driver though -argh). Dell and synaptics have not been helpful. I have checked that syntpehn.exe and syntphelper.exe are running (sometimes the UAC seems to block syntpehn.exe from running at startup). When the touchpad fails i can still use it to control the pointer and access the synaptics settings although some of the options are disabled (greyed out or simply unresponsive). It is the only pointing device i have installed - i had a logitech trackball attached but have uninstalled all software and drivers (including hidden devices) as per synaptic. It is also the only device using IRQ 12. Any help would be greatly appreciated except "update the driver".

    Read the article

  • Windows 7 x64 RTM USB Port Has Power But Won't Recognize Mouse/Keyboard/Anything

    - by ben
    I have an odd error that doesn't seem to fit in with any of the other odd Windows 7 x64 USB errors that have been kicked up on Google. Here we go: Uninstalled Tortoise SVN and clicked restart computer. My machine had been up for around 28 days On reboot my mouse and keyboard failed to work anymore, couldn't log in. Tried every USB port I have on my Dell 390 and the ports on my Dell 19's, nothing worked. They had power but Windows would not respond when I manipulated the keyboard/mouse. Rebooted my computer and pressed F2 to get into bios, my keyboard is working fine in bios. Keyboard and mouse work fine on other computers when using USB. Found adapters for keyboard and mouse to convert from USB to PS/2 ports, works fine. I'm actually typing this question on the same keyboard, same computer, just using PS/2 ports for my mouse and keyboard. It appears to be a Windows 7 x64 issue. Other things I have tried: Multiple other mice and keyboards, iphone, all with no luck. Each one gets power, but Windows never tries to install drivers or sees that they are connected. Uninstall and reinstall all USB drivers. Drives uninstall and reinstall fine and report no errors in Control Panel. In Power Management I disallow Windows from turning off USB ports to save power Installed the latest nVidia drivers for my graphics card, no change. Anyplace else I can look/try? Thanks!

    Read the article

  • Why does my DSDT table is different from what I found online?

    - by Hao Shen
    I have found a field in DSDT table where I want to modify from here http://www.ztex.de/misc/c2ctl.e.html Generally, I want to modify the _PSS field about the processor so that I can have more frequency levels available in the CPUfreq driver interface. I try to use this command to dissemble the DSDT table from my Desktop(Linux2.6.29,Intel CORE 2): cat /proc/acpi/dsdt > dsdt.aml iasl -d dsdt.aml Then I have a file dsdt.dsl as following(very long, so I just show the beginning of the file): /* * Intel ACPI Component Architecture * AML Disassembler version 20090123 * * Disassembly of dsdt.aml, Mon May 6 20:41:40 2013 * * * Original Table Header: * Signature "DSDT" * Length 0x00003794 (14228) * Revision 0x01 **** ACPI 1.0, no 64-bit math support * Checksum 0x46 * OEM ID "DELL" * OEM Table ID "dt_ex" * OEM Revision 0x00001000 (4096) * Compiler ID "INTL" * Compiler Version 0x20050624 (537200164) */ DefinitionBlock ("dsdt.aml", "DSDT", 1, "DELL", "dt_ex", 0x00001000) { Method (DBIN, 0, NotSerialized) { Noop } Scope (\) { Device (_SB.VBTN) ................... But I can not find the _PSS field as shown in the website I have given above. I do not know why? I am sure the current cpufreq driver shows 4 frequency levels available. So at least there should be something in the table showing this..right? Has anybody here played with the DSDT table before? Thanks,

    Read the article

  • How to change my W2k8 System Partition?

    - by Chris May
    On my Windows 2008 server, my C: is 1.5 TB, and the partition is marked as: Healthy (Boot, Page File, Active, Crash Dump, Primary Partition) and somehow I ended up with a 2GB D: that is marked as Healthy (System). On this D: drive are only a few MB worth of files (bootmgr, boot folder, bootsect.bak), but all Windows files are on the c:. I've done everything I can to remove the (System) mark. I tried using bcdedit, I tried marking the C:partition as "Active", I tried using bootsect.exe to assign the C: drive as the boot partition. Maybe I didn't do one of those steps correct, but I've tried everything I can. When I got my new Dell Poweredge T710, I didn't bother removing their 2 small drives before I put in my 2 new large drives. So I think when I installed W2k8 Server, maybe dell left some bootable partition on their drives to help me install the OS, but I never used it and just booted right from the install CD. Can anyone help me remove the (System) mark from the D: so I can remove the D: partition and still boot to the C:? I know I could remove the D: drives and reinstall windows, but I'm trying to avoid a total reinstall.

    Read the article

  • AMD switchable graphics are not working OR I don't know how to make them work

    - by Deus Deceit
    I don't know if this is the right place for this question, but I'll give it a shot. I have a Dell Inspiron 17R 5721. It's supposed to be using switchable graphics. It has an Intel HD 4000 and a Radeon HD 8730M and I'm using windows 8. My problem is this, I Installed the drivers that dell gives me but I don't see the AMD graphics card ANYWHERE ( I do see it in device manager but not anywhere else to select and play a game using AMD). I installed the latest drivers from AMD and same thing, I can't run a game with AMD graphics card. I change the applications preferences in the Catalyst control center but even after that, games don't give me the option to select the AMD card, they list only the Intel HD 4000. Can someone tell me what I have to do to make this work? ------------------- After looking around and messing with stuff. I think.... I THINK that you don't really get the option to select a graphics card. Switchable graphics is all about switching automatically depending on application's needs. Cause when I uninstalled AMD's drivers or actually (screwed up lol) games were playing much worse. When I re-installed them, games went back to being good looking. So even if a game sees only the Intel HD 4000 graphics card windows or AMD's drivers will switch to the AMD Readeon graphics card automatically. I hope someone can verify this. Cause seriously I don't think you get to play scyrim with High graphics settings or even ultra with the Intel HD Graphics card. -------------------

    Read the article

  • Google Chrome warning that Javascript is disabled

    - by kirchoffs415
    I hope somebody can help. I keep getting the following message when I log on: Your Javascript is disabled. Limited functionality is available. It will stay for maybe a day sometimes two. I have uninstalled javascript and reinstalled but still the same. I am using chrome. Any help would be grateful many thanks Dominic My system spec is as follows System InformationOS Name Microsoft® Windows Vista™ Home Premium Version 6.0.6002 Service Pack 2 Build 6002 Other OS Description Not Available OS Manufacturer Microsoft Corporation System Name DOM-PC System Manufacturer Dell Inc. System Model Inspiron 1545 System Type X86-based PC Processor Pentium(R) Dual-Core CPU T4200 @ 2.00GHz, 2000 Mhz, 2 Core(s), 2 Logical Processor(s) BIOS Version/Date Dell Inc. A05, 25/02/2009 SMBIOS Version 2.4 Windows Directory C:\Windows System Directory C:\Windows\system32 Boot Device \Device\HarddiskVolume3 Locale United Kingdom Hardware Abstraction Layer Version = "6.0.6002.18005" User Name DOM-PC\DOM Time Zone GMT Standard Time Installed Physical Memory (RAM) 3.00 GB Total Physical Memory 2.96 GB Available Physical Memory 1.38 GB Total Virtual Memory 5.89 GB Available Virtual Memory 4.25 GB Page File Space 3.00 GB Page File C:\pagefile.sys My System Specs

    Read the article

  • DAS vs SAN storage for serving 2 to 4 nodes

    - by Luke404
    We currently have 4 Linux nodes with local storage, arranged in two active/passive pairs with storage mirrored using DRBD, running virtual machines (actually using Xen Hypervisor) for typical hosting workloads (mail, web, a couple VPS, etc.). We're approaching the (presumed) maximum IOPS of those servers, and we're planning to migrate to an external storage solution with two active nodes, with capacity for up to four active nodes. Since we're an all-Dell shop I've done some research and found the MD3200 / MD3200i products should be the ones we're looking for. We are pretty sure we won't be attaching more than 4 hosts on a single storage and I'm wondering if there is any clear advantage for one or the other. In theory I should be able to attach 4 SAS hosts to a single MD3200 (single links on a single controller MD3200, or dual redundant SAS links from each host to a dual-controller MD3200), or 4 iSCSI hosts to a single MD3200i (directly on its 4 GigE ports without any switch, again with dual links for the dual controller option). Both setups should let us implement live VM migration since all hosts can access all the LUNs at the same time, and also some shared filesystem like GFS2 or OCFS2. Also, both setups should allow full redundancy of the whole system (assuming dual controllers in the storage). One difference I can see is that the DAS solution is actually limited to 4 hosts while the iSCSI one should be able to grow to more hosts (adding two GigE switches to the mix). One point for the iSCSI solution is that it would allow us to start out with our current nodes and upgrade them at a later time (we can't add other SAS controllers, but they already have 4 GigE ports each). With the right (iSCSI|SAS) controllers I should be able to connect diskless nodes and boot them off the external storage which I think is a good thing (get rid of any local storage). On the other hand, I would have thought the SAS one to be cheaper but it seems like an MD3200 actually costs a little less than an MD3200i (?) (please note: I've used Dell gear in my examples since that's what we're looking for but I assume the same goes with other vendors) I would like to know if my assumptions above are correct, and if I'm missing any important difference between the two setups.

    Read the article

  • Anyone else experiencing high rates of linux server crashes today?

    - by Bron Gondwana
    Just today, Sat June 30th - starting soon after the start of the day GMT. We've had a handful of blades in different datacentres as managed by different teams all go dark - not responding to pings, screen blank. They're all running Debian Squeeze - with everything from stock kernel to custom 3.2.21 builds. Most are Dell M610 blades, but I've also just lost a Dell R510 and other departments have lost machines from other vendors too. There was also an older IBM x3550 which crashed and which I thought might be unrelated, but now I'm wondering. The one crash which I did get a screen dump from said: [3161000.864001] BUG: spinlock lockup on CPU#1, ntpd/3358 [3161000.864001] lock: ffff88083fc0d740, .magic: dead4ead, .owner: imapd/24737, .owner_cpu: 0 Unfortunately the blades all supposedly had kdump configured, but they died so hard that kdump didn't trigger - and they had console blanking turned on. I've disabled console blanking now, so fingers crossed I'll have more information after the next crash. Just want to know if it's a common thread or "just us". It's really odd that they're different units in different datacentres bought at different times and run by different admins (I run the FastMail.FM ones)... and now even different vendor hardware. Most of the machines which crashed had been up for weeks/months and were running 3.1 or 3.2 series kernels. The most recent crash was a machine which had only been up about 6 hours running 3.2.21.

    Read the article

  • Synaptics touchpad stops working randomly

    - by Jus12
    I have two laptops. One dell Vostro and other Vaio Z. Both have Synaptics (Yes, I have checked, and the original drivers were from Synaptics as well). On both laptops, the touchpad scrolling stops working at some arbitrary time and nothing seems to solve it except a reboot. Sometimes, it randomly starts working again. I have downloaded all latest drivers from OEM. Interestingly, when I run a program as Administrator, scrolling works in that window only. This problem is very odd. It happens without any reason and I've not been able to find a fix for more than a year. I have seen some unusual suggestions on forums (e.g., to "restore windows to a previous working state") but never any fix that solves this issue properly. I have tried installing latest drivers and I DO NOT want to restore windows to a previous working configuration. OS: Windows 7 64 bit Professional (Sony Vaio Z - VPCZ128GG) Windows 7 32 bit Professional (Dell) Edit: Temporary solution is to uninstall the synaptics driver and let Windows 7 use its default built in one. However, I really prefer the Synaptic driver because it activates the scroll button rather than the mouse wheel (useful in some apps such as MS Photo Editor)

    Read the article

  • How to best tune my SAN/Initiators for best performance?

    - by Disco
    Recent owner of a Dell PowerVault MD3600i i'm experiencing some weird results. I have a dedicated 24x 10GbE Switch (PowerConnect 8024), setup to jumbo frames 9K. The MD3600 has 2 RAID controllers, each has 2x 10GbE ethernet nics. There's nothing else on the switch; one VLAN for SAN traffic. Here's my multipath.conf defaults { udev_dir /dev polling_interval 5 selector "round-robin 0" path_grouping_policy multibus getuid_callout "/sbin/scsi_id -g -u -s /block/%n" prio_callout none path_checker readsector0 rr_min_io 100 max_fds 8192 rr_weight priorities failback immediate no_path_retry fail user_friendly_names yes # prio rdac } blacklist { device { vendor "*" product "Universal Xport" } # devnode "^sd[a-z]" } devices { device { vendor "DELL" product "MD36xxi" path_grouping_policy group_by_prio prio rdac # polling_interval 5 path_checker rdac path_selector "round-robin 0" hardware_handler "1 rdac" failback immediate features "2 pg_init_retries 50" no_path_retry 30 rr_min_io 100 prio_callout "/sbin/mpath_prio_rdac /dev/%n" } } And iscsid.conf : node.startup = automatic node.session.timeo.replacement_timeout = 15 node.conn[0].timeo.login_timeout = 15 node.conn[0].timeo.logout_timeout = 15 node.conn[0].timeo.noop_out_interval = 5 node.conn[0].timeo.noop_out_timeout = 10 node.session.iscsi.InitialR2T = No node.session.iscsi.ImmediateData = Yes node.session.iscsi.FirstBurstLength = 262144 node.session.iscsi.MaxBurstLength = 16776192 node.conn[0].iscsi.MaxRecvDataSegmentLength = 262144 After my tests; i can barely come to 200 Mb/s read/write. Should I expect more than that ? Providing it has dual 10 GbE my thoughts where to come around the 400 Mb/s. Any ideas ? Guidelines ? Troubleshooting tips ?

    Read the article

  • How to Install OS without DVD and USB boot

    - by Timothy James Reed
    I just purchased a used Dell F1D 1U rack mount server and would like to install Ubuntu or ESXi with Virtual Disks or anything for that matter. I'v read that Dell's have built in DRAC so you can access it remotely. There are 3 ethernet plugs in the back but I dont know which one to use. In the BIOS it says I can configure Remote access on [com1] or [com2] not sure if that is ethernet 1 & 2. I also set it up so to use a static IP adress. Thats as far as I have gone. Not sure what to do next. I'v Tried to do a PXE server with TFTP but get stuck at Error "cant locate file" or something like that. Not even sure I want to go that route anymore because of all the hassel of editing files. All my computers are OSX or Linux and the only Windows I have is via VMWare. What steps to i do now?

    Read the article

  • Virtual Windows 2008 Server Activation with ESX

    - by Logman
    I had a decommissioned server (Dell PE2950) that we could still use, it had OEM Windows 2003 Std on it but wanted to use it as a new host with VMware ESX5 to put a couple legacy severs on it. I wiped it clean and maxed out the memory. But when I added the memory I noticed the product key sticker was a "WindowsServer08 Std 1-4cpu" product key, and it also had a Virtual Key. Not sure why it had Win2003 and not Win2008 from the start, but I would like to use that license if I can. The virtual host would stay on the same physical server, so there shouldn't be a problem with licensing... but I do not want to use Hyper-V unless I can not help it. I have installed ESX5 on the server, but I cannot get the Windows 2008 server to activate. The product key is hard to read, and I have checked the key quite a few times. But my question is... Is it because Hyper-V was not installed on the host? But I thought you could use the product key alone on a virtual host? Maybe because I am not using a Dell Windows 2008 disk but iso from MS directly via the Volumne Licensing site? EDIT: well, Im pretty sure I got the product key correct. If its not the product key, could the activation problem be because Im not using hyper-v or maybe the correct install dvd? EDIT2: maybe because I added 28GB of memory? Originally 4GB...

    Read the article

  • How To Replace Laptop HDD Without Losing Data?

    - by Ishan
    Hello, I recently went to Dell Service center and they tell that HDD is faulty and needs to be replaced. I have a Studio 1457 laptop with 500 GB HDD and don't want to lose the data(purchased in May 2010, still under warranty). I have searched a bit and I think it may be best to use a disk imaging software for this task. However, I don't know about a good software. I have following steps in mind: Get a 1 TB External HDD. Make an image of existing 500 GB HDD and store data on external disk. Install new HDD and install a brand new Windows copy and then install the software on it. Using the same software I used to make image, restore the old HDD image on new one. However, I have some questions in mind. First, is this possible? Second, I live in a country where piracy is a big issue and I am sure the support executive who will come to change HDD will have a pirated copy. But I have genuine Windows 7 Pro and don't want to lose it. Now, Dell does not supply and OS disks, so I can't install it on new HDD! If I follow above steps, which version of Windows 7 will be retained? One in the image(authentic) or one in the new HDD(pirated). I am ready to purchase a good software for this task and my budget is $50-60. Since laptop is under warranty, new HDD will be free. One last thing, I have created a Windows Migration file whose size is 70 GB. Can it be used to move from Windows 7 Pro to Windows 7 Pro?(In case I get a genuine copy of Windows 7!) Any other method to save all the data? Thanks in advance.

    Read the article

  • Wireless keeps shutting off in Windows 7

    - by Nathan Adams
    I have Windows 7 Ultimate 32bit installed on a Dell Latitude XT Tablet and for the life of me I can't figure out this really weird problem. The symptom is that the Wireless will disconnect from the AP and if I tell it to scan again, it says there are no APs in the area. I do have another wireless card in the laptop and if I disable the first one and enable the second, I am able to get onto the wireless however if I want to use the first card again I have to restart. I tried enabling/disabling the device, nothing will kick start the wireless again in the first card without a restart. I even tried different drivers. So, it seems it is random but it does occur more often when there is increased network activity (ie downloading a large file). The laptop doesn't seem to be overheating. I have tried the following: Under "Change Advanced Power Settings" for the current power profile, I set the "Wireless Adapter settings" to "Maximum Performance". Under device manger, I went to the card in question, and went to the advanced tab and set the "Power Saving mode" to "MAX_PSP" Both cards I have seem to exhibit the behavior after awhile. Both models of those cards are: Dell Wireless 1505 Draft 802.11n WLAN Mini-Card Gigabyte GN-WS30N 802.11n mini WLAN Card Has anyone have any ideas or ran into this before?

    Read the article

  • Advice on Computer Specs for overall development/general use machine

    - by Ender
    At the moment I am restricted to a laptop with 512MB of RAM, a 120GB HDD and a 1.5GHz Intel processor for all my development and general browsing needs, and as you can probably tell using it for anything modern is a painful experience. As a result I've decided to buy myself a new desktop computer, one that will stand the test of time and one that can be upgraded easily. Rather than build the machine myself I've decided to go through Dell as I've had good experiences with them when purchasing computers for my family. I've had my eye on this as it's got a good amount of RAM, has a decent-rated processor and isn't priced too badly. http://www1.euro.dell.com/uk/en/home/Desktops/inspiron-580/pd.aspx?refid=inspiron-580&s=dhs&cs=ukepp1&~oid=uk~en~20211~inspiron-580_d005827~~ Intel® Core™ i5 Processor 750 (2.66GHz, 8MB) Genuine Windows® 7 Home Premium 64bit - English Display Not Included ATI Radeon™ HD 5450 1GB DDR3 graphics 6144MB Dual Channel DDR3 [3x2048] Memory 1TB (7200rpm) SATA Hard Drive DVD +/- RW Drive (read/write CD & DVD) with DVD Burn software 1 year of coverage included with your PC McAfee® Security Centre - 15 Month Protection - English After the pain of using a slow laptop for all this time the main thing I want is speed. I may look to play a couple of basic games on it, nothing too powerful. Obviously I'll be doing some development on it too so it'll have to be able to handle the latest IDE's and Database tools like SQL Server pretty quickly. Finally, should I ever need to improve it I'd like to be able to add more RAM and change some of the parts. I wouldn't have thought this would be a problem but a few people I've spoken to have said that the amount of RAM the motherboard can handle isn't that great. Is this true? How long can I expect to be using this computer before it's too slow? Thanks in advance for the help.

    Read the article

  • Printer Naming Conventions

    - by John
    I am working on building a new AD print server and have been pondering the idea of renaming the printers. Right now we have a mix of names that varies between a mashup of some that reference location, some that reference functional area, and some that are rather generic. Some examples include the following: Dell 5210 - Building Name HP 4350 - Functional Area Dell Color 3100 - Location and Building Number HP 6500 - Mailroom I was curious what other people used to name their printers with. What conventions do you use and how to design a method that will be able to be used for a while without needing to rename them all again. Also, the naming methodology needs to be understandable for regular computing users so that they can relatively easily find the printer that they need. I was looking at some ideas from here, but I was not sure how practical some of them are. Any help that you can provide is appreciated. Note: I have reviewed many of the postings on here in relation to server naming conventions and found that they were not specific enough for the use case I present above.

    Read the article

  • Unable to connect to server after a certain amount of time

    - by Troy
    I am a business FIOS subscriber with 5 static IPs. I have the following network setup: Verizon provided ONT Dlink switch Dell server running Ubuntu 12.04 with iptables enabled and a static IP address. The makes/models of hardware are: FIOS ONT Alcatel-Lucent I-211M-H ONT D-Link D-Link Web Smart Switch DES-1228P Server Dell Optiplex 755 (Ubuntu 12.04 Server) I have iptables running on the server with http, https and ssh ports open. I can connect to a website on the server from an external computer, but after a certain amount of time (mins to hours), I can no longer connect. All I have to do to re-enable connectivity is connect to the server via SSH from a computer INSIDE the network. I don't have to actually login, I just have to establish a connection. I can then access the website externally again. I did some googling and it seems some of verizon's equipment had an ARP bug where the ARP entries would expire after a certain time period, but those issues all seem to be from back in 2009 - 2010. I know the switch has an 'auto learning Mac address' feature, but I'm not sure if that could be the problem or not. Does anyone have any ideas or advice on how I can troubleshoot this? Thanks!

    Read the article

  • RAID 10 or RAID 5 for multiple VMs - what is the best choice?

    - by Lars Fastrup
    I have just ordered a new rig for my business. We do a lot of software development for Microsoft SharePoint and need the rig to run several virtual machines for development and test purposes. We will be using the free VMware ESXi for virtualization. For a start, we plan to build and start the following VMs - all with Windows Server 2008 R2 x64: Active Directory server MS SQL Server 2008 R2 Automated Build Server SharePoint 2010 Server for hosting our public Web site and our internal Intranet for a few people. The load on this server is going to be quite insignificant. 2xSharePoint 2007 development server 2xSharePoint 2010 development server Beyond that we will need to build several SharePoint farms for testing purposes. These VMs will only be started when needed. The specs of the new rig is: Dell R610 rack server 2xIntel XEON E5620 48GB RAM 6x146GB SAS drives Dell H700 RAID controller We believe the new server is going to make our VMs perform a lot better than our existing setup (2xIntel XEON, 16GB RAM, 2x500 GB SATA in RAID 1). But we are not sure about the RAID level for the new rig. Should we go for having the the 6x146GB SAS drives in a RAID 10 configuration or a RAID 5 configuration? RAID 10 seems to offer better write performance and lower risk of a RAID failure. But it comes at a cost of less drive space. Do we need RAID 10 or would RAID 5 also be a good choice for us?

    Read the article

  • Dual-head monitor system Kubuntu 10.04

    - by andrii
    I have a notebook Asus V6X00V with 1400*1050 monitor(name: LVDS) and Dell Monitor 1920*1080 (VGA-0). I want to have a dual monitor system. At MS Windows everything is working fine. During the Kubuntu installation the Dell and the main notebook monitors have a right resolutions(1920*1080 & 1400*1050). But after some stage it have been changed to the 1152*864 for both. Now the right resolution is only during turning off process and when I am using the console. So it shows that system can use this resolutions. The problem is just in a settings. I am using Size & Orientation - System Settings for setting adjustment. Any option that changes resolution for any monitor or changing position(Absolute, Left Of, Right of and so on) cause the color line noise on the screens. I have tried xrandr: xrandr --output LVDS --mode 1400x1050 --pos 0x0 --output VGA-0 --mode 1920x1080 --right-of LVDS --pos 1400x0 but have received the same result. I have find out that for example the previous version of Randr(1.2, now I have xrandr 1.3) need a xorg.conf file modification to create a big virtual screen, but kubuntu 10.4 don't have xorg.conf and I don't know should I modify xorg for 1.3 version of xrandr or not. Please help me to solve this problem

    Read the article

< Previous Page | 48 49 50 51 52 53 54 55 56 57 58 59  | Next Page >