Search Results

Search found 28989 results on 1160 pages for 'modal view controller'.

Page 54/1160 | < Previous Page | 50 51 52 53 54 55 56 57 58 59 60 61  | Next Page >

  • Areca 1280ml RAID6 volume set failed

    - by Richard
    Today we hit some kind of worst case scenario and are open to any kind of good ideas. Here is our problem: We are using several dedicated storage servers to host our virtual machines. Before I continue, here are the specs: Dedicated Server Machine Areca 1280ml RAID controller, Firmware 1.49 12x Samsung 1TB HDDs We configured one RAID6-set with 10 discs that contains one logical volume. We have two hot spares in the system. Today one HDD failed. This happens from time to time, so we replaced it. Upon rebuilding a second disc failed. Normally this is no fun. We stopped heavy IO-operations to ensure a stable RAID rebuild. Sadly the hot-spare disc failed while rebuilding and the whole thing stopped. Now we have the following situation: The controller says that the raid set is rebuilding The controller says that the volume failed It is a RAID 6 system and two discs failed, so the data has to be intact, but we cannot bring the volume online again to access the data. While searching we found the following leads. I don't know whether they are good or bad: Mirroring all the discs to a second set of drives. So we would have the possibility to try different things without loosing more than we already have. Trying to rebuild the array in R-Studio. But we have no real experience with the software. Pulling all drives, rebooting the system, changing into the areca controller bios, reinserting the HDDs one-by-one. Some people are saying that the brought the system online by this. Some are saying that the effect is zero. Some say, that they blew the whole thing. Using undocumented areca commands like "rescue" or "LeVel2ReScUe". Contacting a computer forensics service. But whoa... primary estimates by phone exceeded 20.000€. That's why we would kindly ask for help. Maybe we are missing the obvious? And yes of course, we have backups. But some systems lost one week of data, thats why we'd like to get the system up and running again. Any help, suggestions and questions are more than welcome.

    Read the article

  • How to Rebuilt Global Catalog?

    - by SZayat
    I am running two domain controllers in a windows 2003 r2 infrastructure. The main domain controller with the global catalog role went down and I had to reformat it. Now I am facing issues with creating new users in the active directory. I think I must create a global catalog but how? or is it possible since the original domain controller is not there anymore? Thanks in advance

    Read the article

  • IT merger - self-sufficient site with domain controller VS thin clients outpost with access to termi

    - by imagodei
    SITUATION: A larger company acquires a smaller one. IT infrastructure has to be merged. There are no immediate plans to change the current size or role of the smaller company - the offices and production remain. It has a Win 2003 SBS domain server, Win 2000 file server, linux server for SVN and internal Wikipedia, 2 or 3 production machines, LTO backup solution. The servers are approx. 5 years old. Cisco network equippment (switches, wireless, ASA). Mail solution is a hosted Exchange. There are approx. 35 desktops and laptops in the company. IT infrastructure unification: There are 2 IT merging proposals. 1.) Replacing old servers, installing Win Server 2008 domain controller, and setting up either subdomain or domain trust to a larger company. File server and other servers remain local and synchronization should be set up to a centralized location in larger company. Similary with the backup - it remains local and if needed it should be replicated to a centralized location. Licensing is managed by smaller company. 2.) All servers are moved to a centralized location in larger company. As many desktop machines as possible are replaced by thin clients. The actual machines are virtualized and hosted by Terminal server at the same central location. Citrix solutions will be used. Only router and site-2-site VPN connection remain at the smaller company. Backup internet line to insure near 100% availability is needed. Licensing is mainly managed by larger company. Only specialized software for PCs that will not be virtualized is managed by smaller company. I'd like to ask you to discuss both solutions a bit. In your opinion, which is better from the operational point of view? Which is more reliable, cheaper in the long run? Easier to manage from the system administrator's point of view? Easier on the budget and easier to maintain from IT department's point of view? Does anybody have any experience with the second option and how does it perform in production environment? Pros and cons of both? Your input will be of great significance to me. Thank you very much!

    Read the article

  • How to use generic (NSObject) controller with subviews of a UIViewController?

    - by wanderlust
    I have a UIViewController that is loading several subviews at different times based on user interaction. I originally built all of these subviews in code, with no nib files. Now I am moving to nib files with custom UIView subclasses. Some of these subviews display static data, and I am using loadNibNamed:owner:options: to load them into the view controller. Others contain controls that I need to access. I (sort of) understand the reasons Apple says to use one view controller per screen of content, using generic controller objects (NSObjects) to manage subsections of a screen. So I need a view controller, a generic controller, a view class and a nib. How do I put this all together? My working assumptions and subsequent questions: I will associate the view class with the nib in the 'class identity' drop down in IB. The view controller will coordinate overall screen interactions. When necessary, it will create an instance of the generic controller. Does the generic controller load the nib? How? Do I define the outlets and actions in that view class, or should they be in the generic controller? How do I pass messages between the view controller and the generic controller? If anyone can point me to some sample code using a controller in this way, it will go a long way to helping me understand. None of the books or stackoverflow posts I've read have quite hit the spot yet.

    Read the article

  • passing multiple queries to view with codeigniter

    - by LvS
    I am trying to build a forum with Codeigniter. So far i have the forums themselves displayed and the threads displayed, based on the creating dynamic news tutorial. But that is 2 different pages, i need to obviously display them into one page, like this: Forum 1 - thread 1 - thread 2 - thread 3 Forum 2 - thread 1 - thread 2 etc. And then the next step is obviously to display all the posts in a thread. Most likely with some pagination going on. But that is for later. For now i have the forum controller (slimmed version): <?php class Forum extends CI_Controller { public function __construct() { parent::__construct(); $this->load->model('forum_model'); $this->lang->load('forum'); $this->lang->load('dutch'); } public function index() { $data['forums'] = $this->forum_model->get_forums(); $data['title'] = $this->lang->line('title'); $data['view'] = $this->lang->line('view'); $this->load->view('templates/header', $data); $this->load->view('forum/index', $data); $this->load->view('templates/footer'); } public function view($slug) { $data['forum_item'] = $this->forum_model->get_forums($slug); if (empty($data['forum_item'])) { show_404(); } $data['title'] = $data['forum_item']['title']; $this->load->view('templates/header', $data); $this->load->view('forum/view', $data); $this->load->view('templates/footer'); } } ?> And the forum_model (also slimmed down) <?php class Forum_model extends CI_Model { public function __construct() { $this->load->database(); } public function get_forums($slug = FALSE) { if ($slug === FALSE) { $query= $this->db->get('forum'); return $query->result_array(); } $query = $this->db->get_where('forum', array('slug' => $slug)); return $query->row_array(); } public function get_threads($forumid, $limit, $offset) { $query = $this->db->get_where('thread', array('forumid', $forumid), $limit, $offset); return $query->result_array(); } } ?> And the view file <?php foreach ($forums as $forum_item): ?> <h2><?=$forum_item['title']?></h2> <div id="main"> <?=$forum_item['description']?> </div> <p><a href="forum/<?php echo $forum_item['slug'] ?>"><?=$view?></a></p> <?php endforeach ?> Now that last one, i would like to have something like this: <?php foreach ($forums as $forum_item): ?> <h2><?=$forum_item['title']?></h2> <div id="main"> <?=$forum_item['description']?> </div> <?php foreach ($threads as $thread_item): ?> <h2><?php echo $thread_item['title'] ?></h2> <p><a href="thread/<?php echo $thread_item['slug'] ?>"><?=$view?></a></p> <?php endforeach ?> <?php endforeach ?> But the question is, how do i get the model to return like a double query to the view, so that it contains both the forums and the threads within each forum. I tried to make a foreach loop in the get_forum function, but when i do this: public function get_forums($slug = FALSE) { if ($slug === FALSE) { $query= $this->db->get('forum'); foreach ($query->row_array() as $forum_item) { $thread_query=$this->get_threads($forum_item->forumid, 50, 0); } return $query->result_array(); } $query = $this->db->get_where('forum', array('slug' => $slug)); return $query->row_array(); } i get the error A PHP Error was encountered Severity: Notice Message: Trying to get property of non-object Filename: models/forum_model.php Line Number: 16 I hope anyone has some good tips, thanks! Lenny *EDIT*** Thanks for the feedback. I have been puzzling and this seems to work now :) $query= $this->db->get('forum'); foreach ($query->result() as $forum_item) { $forum[$forum_item->forumid]['title']=$forum_item->title; $thread_query=$this->db->get_where('thread', array('forumid' => $forum_item->forumid), 20, 0); foreach ($thread_query->result() as $thread_item) { $forum[$forum_item->forumid]['thread'][]=$thread_item->title; } } return $forum; } What is now next, is how to display this multidimensional array in the view, with foreach statements.... Any suggestions ? Thanks

    Read the article

  • NavigationBar from UINavigationController not positioned correctly

    - by David Liu
    So, my iPad program has a pseudo-split view controller (one that I implemented, not base SDK one), and was working correctly a while ago. It has the basic layout (UINavController for master, content view controller for detail on right), but I have it so the master view doesn't disappear when rotated into portrait view. Recently, I added in a UITabBarController to contain the entire split view, which has made the navigation bar go wonky, while all the other views are positioned fine. In addition, the navigation bar only gets mispositioned when the program starts up while the iPad is in landscape, or upside-down portrait. If it starts out in portrait, everything is fine. Relevant Code: RootViewController.m: - (void)loadView { navController = [[NavigationBreadcrumbsController_Pad alloc] init]; ABTableViewController_Pad * tableViewController = [[ABTableViewController_Pad alloc] initWithNibName:@"ABTableView"]; master = [[UINavigationController_Pad alloc] initWithRootViewController:tableViewController]; [tableViewController release]; // Dummy blank UIViewcontroller detail = [[UIViewController alloc] init]; detail.view = [[[UIView alloc] init] autorelease]; [detail.view setBackgroundColor:[UIColor grayColor]]; self.view = [[[UIView alloc] init] autorelease]; self.view.backgroundColor = [UIColor blackColor]; [self positionViews]; [self.view addSubview:navToolbarController.view]; [self.view addSubview:master.view]; [self.view addSubview:detail.view]; } // Handles the respositioning of view into it's current orientation -(void)positionViews{ CGFloat tabBarOffset = 0; if(self.tabBarController){ tabBarOffset = self.tabBarController.tabBar.frame.size.height; } if(self.interfaceOrientation == UIInterfaceOrientationPortrait || self.interfaceOrientation == UIInterfaceOrientationPortraitUpsideDown) { self.view.frame = CGRectMake(0, 0, 768, 1004); navController.view.frame = CGRectMake(0,0,768,44); //adjust master view [master.view setFrame:CGRectMake(0, 44, 320, 1024 - 44 - 20 - tabBarOffset)]; //adjust detail view [detail.view setFrame:CGRectMake(321,44, 448, 1024 - 44 - 20 - tabBarOffset)]; } // Landscape Layout else{ self.view.frame = CGRectMake(0, 0, 748, 1024); navToolbarController.view.frame = CGRectMake(0,0,1024,44); //adjust master view [master.view setFrame:CGRectMake(0, 44, 320, 768 - 44 - 20 - tabBarOffset)]; //adjust detail view [detail.view setFrame:CGRectMake(321,44, 1024 - 320, 768 - 44 - 20 - tabBarOffset)]; } }

    Read the article

  • SQL. Sorting by a field

    - by strakastroukas
    I have created a simple view consisting of 3 tables in SQL. By right clicking and selecting Design, in the Object explorer table, i modified my custom view. I just added sortby asc in a field. The problem is that the changes are not reflected in the outout of the View. After saving the view, and selecting Open view the sort is not displayed in output. So what is going on here?

    Read the article

  • Bad disk performance on HP DL360 with Smarty Array P400i RAID controller

    - by sarge
    I have a HP DL360 server with 4x 146GB SAS disks and a Smart Array P400i RAID controller with 256MB cache. The disks are in RAID 5 (3 disks + 1 hot spare). The server is running VMware ESX 3i. The disk write performance is really bad. Here are some numbers: ns1:~# hdparm -tT /dev/sda /dev/sda: Timing cached reads: 3364 MB in 2.00 seconds = 1685.69 MB/sec Timing buffered disk reads: 18 MB in 3.79 seconds = 4.75 MB/sec ns1:~# time sh -c "dd if=/dev/zero of=ddfile bs=8k count=125000 && sync" 125000+0 records in 125000+0 records out 1024000000 bytes (1.0 GB) copied, 282.307 s, 3.6 MB/s real 4m52.003s user 0m2.160s sys 3m10.796s Compared to another server those number are terrible: Dell R200, 2x 500GB SATA disks, PERC raid controller (disks are mirrored). web4:~# hdparm -tT /dev/sda /dev/sda: Timing cached reads: 6584 MB in 2.00 seconds = 3297.79 MB/sec Timing buffered disk reads: 316 MB in 3.02 seconds = 104.79 MB/sec web4:~# time sh -c "dd if=/dev/zero of=ddfile bs=8k count=125000 && sync" 125000+0 records in 125000+0 records out 1024000000 bytes (1.0 GB) copied, 35.2919 s, 29.0 MB/s real 0m36.570s user 0m0.476s sys 0m32.298s The server isn't very loaded and the VMware Infrastructure Client performance monitor is showing 550KBps average read and 1208KBps average write for the last 30 minutes (highest write rate: 6.6MBps). This has been a problem from the start. Any ideas?

    Read the article

  • Windows 2003 Domain Controller Very Upset about NIC Teaming

    - by Kyle Brandt
    I set up BACS (Broadcom Teaming) to team two NIC on a Windows 2003 Active Directory Domain Controller. Networking still works okay, I can ping the gateway etc, but both DNS and Active Directory fail to start with various 40xx errors. The team that I created is Smart load Balancing with Failover, with one backup and only one in smart load balancing (So really it is just failover). I have the team the same IP address that the single active NIC had before. Anyone seen this before, or have any ideas what the problem might be? Event Type: Error Event Source: DNS Event Category: None Event ID: 4015 Date: 3/7/2010 Time: 10:33:03 AM User: N/A Computer: ADC Description: The DNS server has encountered a critical error from the Active Directory. Check that the Active Directory is functioning properly. The extended error debug information (which may be empty) is "". The event data contains the error. Event Type: Error Event Source: DNS Event Category: None Event ID: 4004 Date: 3/7/2010 Time: 10:33:03 AM User: N/A Computer: ADC Description: The DNS server was unable to complete directory service enumeration of zone .. This DNS server is configured to use information obtained from Active Directory for this zone and is unable to load the zone without it. Check that the Active Directory is functioning properly and repeat enumeration of the zone. The extended error debug information (which may be empty) is "". The event data contains the error. Event Type: Error Event Source: NTDS Replication Event Category: DS RPC Client Event ID: 2087 Date: 3/7/2010 Time: 10:40:28 AM User: NT AUTHORITY\ANONYMOUS LOGON Computer: ADC Description: Active Directory could not resolve the following DNS host name of the source domain controller to an IP address. This error prevents additions, deletions and changes in Active Directory from replicating between one or more domain controllers in the forest. Security groups, group policy, users and computers and their passwords will be inconsistent between domain controllers until this error is resolved, potentially affecting logon authentication and access to network resources.

    Read the article

  • Red Hat 5.3 on HP Proliant DL380 G5 and failed drive on RAID controller

    - by thinkdreams
    I have a development ERP server here in my office that I assist with support on, and originally the DBA requested a single drive setup for some of the drives on the server. Thus the hardware RAID controller (an HP embedded controller) looks like: c0d0 (2 drive) RAID-1 c0d1 (2 drive) RAID-1 c0d2 (1 drive) No RAID <-- Failed c0d3 (1 drive) No RAID c0d4 (1 drive) No RAID c0d5 (1 drive) No RAID c0d2 has failed. I replaced the drive immediately with a spare using the hot-swap, but the c0d2 continues to mark itself as failed, even when I umount the partition. I'm loathe to reboot the server since I'm concerned about the server coming back up in rescue mode but I'm afraid that's the only way to get the system to re-read the drive. I assumed there was some sort of auto-detection routine for this, but I haven't been able to figure out the proper procedure. I have installed the HP ACU CLI utilties, so I can see the hardware RAID setup. I'd really like to find out what the proper procedure should have been, where I went wrong, and how to correct it now. Obviously this goes without saying I should NOT have listened to the DBA and set the drives up as RAID-1 throughout as was my first instinct. He wasn't worried about data loss, but it sure would have been easier to replace the failed drive. :)

    Read the article

  • Slow parity initialization of RAID-5 array on HP Smart Array 411 controller

    - by Rob Nicholson
    On 29th October 2011, I built a RAID-5 array using 4 x 146.8GB Seagate SAS ST3146855SS drives running at 15k connected to a PowerEdge R515 with HP Smart Array P411 controller running Windows 2008 (so nothing particularly unusual). I know that parity initialisation of a RAID-5 array can take some time but it's still running after 2.5 weeks which seems a little unusual. I'd previously built another array on the same controller using 4 x 2TB SATA-2 drives and that did take a while to complete but a) I'm sure it was less than 2.5 weeks, b) that array was ~12 times bigger and c) during initialization, the percentrage slowly increased each day. At the moment, the status display for this new 2nd array simply says "Parity Initialization Status: In Progress" and it's said that since the start. It's this lack of change on the status that worries me the most - feels like it's not actually doing anything. Do you think something has gone wrong or am I being unpatient and for some reason, the status not increasing is normal? I kind of expected a much smaller array on faster drives (15k SAS versus 7.5k SATA-2) to build in a few days. This is our primary SAN running StarWind so my "have a play" options are very limited. This 2nd array is currently in use for one small virtual disk so I could shut the target machine down, move the virtual disk to another drive and try rebuilding.

    Read the article

  • Using smartctl to get vendor specific Attributes from ssd drive behind a SmartArray P410 controller

    - by Lairsdragon
    Recently I have deployed some HP server with SSD's behind a SmartArray P410 controller. While not official supported from HP the server work well sofar. Now I like to get wear level info's, error statistics etc from the drive. While the SA P410 supports a passthru of the SMART Command to a single drive in the array the output I was not able to the the interesting things from the drive. In this case especially the value the Wear level indicator is from interest for me (Attr.ID 233), but this is ony present if the drive is directly attanched to a SATA Controller. smartctl on directly connected ssd: # smartctl -A /dev/sda smartctl version 5.38 [x86_64-unknown-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF READ SMART DATA SECTION === SMART Attributes Data Structure revision number: 5 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 3 Spin_Up_Time 0x0000 100 000 000 Old_age Offline In_the_past 0 4 Start_Stop_Count 0x0000 100 000 000 Old_age Offline In_the_past 0 5 Reallocated_Sector_Ct 0x0002 100 100 000 Old_age Always - 0 9 Power_On_Hours 0x0002 100 100 000 Old_age Always - 8561 12 Power_Cycle_Count 0x0002 100 100 000 Old_age Always - 55 192 Power-Off_Retract_Count 0x0002 100 100 000 Old_age Always - 29 232 Unknown_Attribute 0x0003 100 100 010 Pre-fail Always - 0 233 Unknown_Attribute 0x0002 088 088 000 Old_age Always - 0 225 Load_Cycle_Count 0x0000 198 198 000 Old_age Offline - 508509 226 Load-in_Time 0x0002 255 000 000 Old_age Always In_the_past 0 227 Torq-amp_Count 0x0002 000 000 000 Old_age Always FAILING_NOW 0 228 Power-off_Retract_Count 0x0002 000 000 000 Old_age Always FAILING_NOW 0 smartctl on P410 connected ssd: # ./smartctl -A -d cciss,0 /dev/cciss/c1d0 smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net (Right, it is complety empty) smartctl on P410 connected hdd: # ./smartctl -A -d cciss,0 /dev/cciss/c0d0 smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net Current Drive Temperature: 27 C Drive Trip Temperature: 68 C Vendor (Seagate) cache information Blocks sent to initiator = 1871654030 Blocks received from initiator = 1360012929 Blocks read from cache and sent to initiator = 2178203797 Number of read and write commands whose size <= segment size = 46052239 Number of read and write commands whose size > segment size = 0 Vendor (Seagate/Hitachi) factory information number of hours powered up = 3363.25 number of minutes until next internal SMART test = 12 Do I hunt here a bug, or is this a limitation of the p410 SMART cmd Passthru?

    Read the article

  • how to initialize two logical drives on a HP P400i controller without reboot

    - by John
    What I am trying to do is initialize two logical drives on a HP P400i embedded controller without a reboot of the system here my current Array config: array A (SAS, Unused Space: 0 MB) logicaldrive 1 (17.9 GB, RAID 5, OK) logicaldrive 2 (17.9 GB, RAID 5, OK) logicaldrive 3 (75.9 GB, RAID 5, OK) logicaldrive 4 (25.0 GB, RAID 5, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 72 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 72 GB, OK) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 72 GB, OK) array B (SAS, Unused Space: 0 MB) logicaldrive 5 (99 MB, RAID 0, OK) logicaldrive 6 (68.2 GB, RAID 0, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 72 GB, OK) windows 2003 machine running the HpCISs2.sys driver version 6.20.0.32 . I have the ACU and ACU CLI tools installed version 8.28.13.0, P400i firmware version 2.74 . Now what I'd like to do is removes the physical drive 1I:1:4 and delete the two logical drives in array B. then insert a new drive in to bay 4 that contains two new logical drives and have them show up in array B again. So far after I remove the drive and delete the failed logical drives, I insert the new drive and run HPacucli rescan. I get the new drive to show up as unassinged physical drive but I cant figure out now to "for lack of a better word" mount the 2 logical drives on the new unassinged disk. If I reboot the system the array controller picks up the new fourth drive and creates Array B with the drives without problem but I'd really like to not have to reboot the server. Any ideas?

    Read the article

  • Domain Controller DNS Best Practice/Practical Considerations for Domain Controllers in Child Domains

    - by joeqwerty
    I'm setting up several child domains in an existing Active Directory forest and I'm looking for some conventional wisdom/best practice guidance for configuring both DNS client settings on the child domain controllers and for the DNS zone replication scope. Assuming a single domain controller in each domain and assuming that each DC is also the DNS server for the domain (for simplicity's sake) should the child domain controller point to itself for DNS only or should it point to some combination (primary VS. secondary) of itself and the DNS server in the parent or root domain? If a parentchildgrandchild domain hierarchy exists (with a contiguous DNS namespace) how should DNS be configured on the grandchild DC? Regarding the DNS zone replication scope, if storing each domain's DNS zone on all DNS servers in the domain then I'm assuming a DNS delegation from the parent to the child needs to exist and that a forwarder from the child to the parent needs to exist. With a parentchildgrandchild domain hierarchy then does each child forward to the direct parent for the direct parent's zone or to the root zone? Does the delegation occur at the direct parent zone or from the root zone? If storing all DNS zones on all DNS servers in the forest does it make the above questions regarding the replication scope moot? Does the replication scope have some bearing on the DNS client settings on each DC?

    Read the article

  • Linux - real-world hardware RAID controller tuning (scsi and cciss)

    - by ewwhite
    Most of the Linux systems I manage feature hardware RAID controllers (mostly HP Smart Array). They're all running RHEL or CentOS. I'm looking for real-world tunables to help optimize performance for setups that incorporate hardware RAID controllers with SAS disks (Smart Array, Perc, LSI, etc.) and battery-backed or flash-backed cache. Assume RAID 1+0 and multiple spindles (4+ disks). I spend a considerable amount of time tuning Linux network settings for low-latency and financial trading applications. But many of those options are well-documented (changing send/receive buffers, modifying TCP window settings, etc.). What are engineers doing on the storage side? Historically, I've made changes to the I/O scheduling elevator, recently opting for the deadline and noop schedulers to improve performance within my applications. As RHEL versions have progressed, I've also noticed that the compiled-in defaults for SCSI and CCISS block devices have changed as well. This has had an impact on the recommended storage subsystem settings over time. However, it's been awhile since I've seen any clear recommendations. And I know that the OS defaults aren't optimal. For example, it seems that the default read-ahead buffer of 128kb is extremely small for a deployment on server-class hardware. The following articles explore the performance impact of changing read-ahead cache and nr_requests values on the block queues. http://zackreed.me/articles/54-hp-smart-array-p410-controller-tuning http://www.overclock.net/t/515068/tuning-a-hp-smart-array-p400-with-linux-why-tuning-really-matters http://yoshinorimatsunobu.blogspot.com/2009/04/linux-io-scheduler-queue-size-and.html For example, these are suggested changes for an HP Smart Array RAID controller: echo "noop" > /sys/block/cciss\!c0d0/queue/scheduler blockdev --setra 65536 /dev/cciss/c0d0 echo 512 > /sys/block/cciss\!c0d0/queue/nr_requests echo 2048 > /sys/block/cciss\!c0d0/queue/read_ahead_kb What else can be reliably tuned to improve storage performance? I'm specifically looking for sysctl and sysfs options in production scenarios.

    Read the article

  • pxe boot dos 7.x / 8.x on modern mainboard without floppy controller

    - by GitaarLAB
    How to pxe boot MS DOS 7.x / 8.x on a modern pc (mainboard without floppy controller) without using an external usb floppy drive? MS DOS 6.22 and earlier or other flavors pxe boot just fine on floppy-less hardware. But DOS 7.x and 8.x renders an error on boot: "Type the name of the Command Interpreter (e.g., C:\WINDOWS\COMMAND.COM) I read somewhere during research this was a rather unknown error, that started to become more common due to the advent of floppy-controller-less hardware. On some hardware (bios dependent) one could plug a usb-floppy-drive in the computer before booting (but that MIGHT also require it to be a "golden floppy drive" (as they where called back then). From a russian site (I read about a year ago and cannot find the hyperlink) MS-Dos versions 6.22 did some-kind of floppy-drive reset during initialization and since it couldn't connect to the floppy-host thus the error. How can I resolve this (without a physical external usb floppy)? Might there be some kind of virtual floppy-driver that could resolve this (for example to be loaded before the dos image loads)? Or could someone point me into the right direction (maybe even a hex-address and some further explanation or something)? I'm using syslinux by the way.

    Read the article

  • Restricting access to one controller of an MVC app with Nginx

    - by kgb
    I have an MVC app where one controller needs to be accessible only from several ips(this controller is an oauth token callback trap - for google/fb api tokens). My conf looks like this: geo $oauth { default 0; 87.240.156.0/24 1; 87.240.131.0/24 1; } server { listen 80; server_name some.server.name.tld default_server; root /home/user/path; index index.php; location /oauth { deny all; if ($oauth) { rewrite ^(.*)$ /index.php last; } } location / { if ($request_filename !~ "\.(phtml|html|htm|jpg|jpeg|gif|png|ico|css|zip|tgz|gz|rar|bz2|doc|xls|exe|pdf|ppt|txt|tar|mid|midi|wav|bmp|rtf|js|xlsx)$") { rewrite ^(.*)$ /index.php last; break; } } location ~ \.php$ { fastcgi_pass unix:/var/run/php5-fpm.sock; fastcgi_index index.php; include fastcgi_params; } } It works, but does not look right. The following seems logical to me: location /oauth { allow 87.240.156.0/24; deny all; rewrite ^(.*)$ /index.php last; } But this way rewrite happens all the time, allow and deny directives are ignored. I don't understand why...

    Read the article

  • Cannot access Domain Controller through VPN

    - by Markus
    In our small network there is a Windows 2008 R2 Domain Controller that also serves as Remote Access Server. For years, we could access this server and the resources in the network over a VPN connection without any problem. Since some time however, I am able to connect to the VPN, but my Windows 8 client (and another one I used for testing purposes) is not able to connect the domain controller afterwards. I can access any other server in the network, but there seems to be a problem regarding the trust between the client(s) and the server. If I connect the client to the network directly over a LAN cable, everything works as expected. Also I can connect to another server over VPN and open a RDP prompt to the DC without a problem. On the client, whenever I try to access the DC, I get an access denied message. I've tried to update the group policies both over VPN and LAN. Also, I've removed the client from the domain and re-added it. The client shows a message that Windows requires valid login information when connected to the VPN - but my credentials are valid. They work when I logon to the client when not connected to the VPN and also when connected to the LAN. Turning off the firewall on the client and the server did not change anything. DNS resolution works both on the server and the client. What else can I do to diagnose and solve the problem?

    Read the article

  • How to run report in ReportViewer without having to click View Report button?

    - by user259286
    I've set up my report with params and it's value. When I run the page, it wants me to click the View Report button, but I need it to just run instead of interacting. Any ideas on this? Here's my code: rptViewer.Reset(); rptViewer.ProcessingMode = ProcessingMode.Remote; rptViewer.ServerReport.ReportServerUrl = new Uri("http://rptserver/reportserver"); rptViewer.ServerReport.ReportPath = "/Reports/My Report"; ReportParameterInfoCollection param = rptViewer.ServerReport.GetParameters(); ReportParameter[] rps = new ReportParameter[] {new ReportParameter(param[0].Name, param[0].ValidValues[0].Value)}; rptViewer.ServerReport.SetParameters(rps); IReportServerCredentials netCred = new CustomReportCredentials("me", "pwd", "domain"); rptViewer.ServerReport.ReportServerCredentials = netCred; rptViewer.ServerReport.Refresh(); rptViewer.SizeToReportContent = true; Thanks!

    Read the article

  • Android equivalent work-around for View.getX() before API 11?

    - by user48998
    I'm using the getX() and getY() method on a view for some special dragging logic (not animation, i.e. I never use setX/Y methods, I just need the getters to check). However, I've come to realize that these are only available post-API 11. The docs for getX() say that is it the addition of the 'left' property and the 'translationX' property. All well and good, except get/setTranslationX() is only around since API 11 as well. I was wondering if there was any knowledge on what this method returns behind the scenes, so I could maybe put in a workaround. Thanks for any help - Chase

    Read the article

  • How to make a slide gesture in a view?

    - by AedonEtLIRA
    I have a grid layout that holds a limited 6 items per screen. This set number is just a base for the app and make it look and feel better so it must stay set to that. To get passed this and to add some flash to the app, I want to animate a style of screen change. For instance, when a finger is dragged left, push the current view to the side and bring the next it, very similar to how a gallery does it, except I would like it to be able to scroll vertical as well. Any help or tutorials will be appreciated ~Aedon.

    Read the article

  • Rails view error "invalid byte sequence in US-ASCII" error after upgrading Ruby to 1.9.2

    - by Jon
    Running Rails 2.3.9 and just upgraded to Ruby 1.9.2p0. I have been putting: # encoding: utf-8 in a bunch of my .rb files where ever "£" character is used, and this seems to be working. But i just got my first view error: invalid byte sequence in US-ASCI for this line of code: <%= number_to_currency(product.price, :unit => "£", :precision => 0) %> I don't think its a coincidence that the "£" character is involved again. Any ideas on how to solve this please? Thanks

    Read the article

  • What's in-memory database technology that do realtime materialized view?

    - by KA100
    What I'm looking for is something like materialized views in front-end that shows my data in diffident ways without full recalculation. let's say I have stock watcher with many front-end views and dashborads some based on aggregation, order by or just filter with different criteria defined realtime by user. Now, I receive online record updates from some webservice and it's not like "data warehouse" every single record can be updated any time and it actually happens every second. Is there any technology can help me in such I create something like materialized view and it's update it without doing full recalculation every time data changed. Thank you.

    Read the article

  • Artec TV18R Tuner not working :(

    - by Antillar Maximus
    Can somebody kindly help me setup my TV Tuner stick? Make and Model: Artec TV18R USB TV Tuner OS: Ubuntu 11.10 64bit Hardware: MSI MS1656-US (GX640 barebones): i5 580M, 2xIntel X25M SSDs, Radeon HD5850M,Realtek sound. Logs and messages: antillar@antillar-MS-1656:/usr/share/dvb/atsc$ [B][COLOR=Red]sudo lsusb[/COLOR][/B] Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 002 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 001 Device 002: ID 8087:0020 Intel Corp. Integrated Rate Matching Hub Bus 002 Device 002: ID 8087:0020 Intel Corp. Integrated Rate Matching Hub Bus 002 Device 003: ID ffc0:001f Bus 002 Device 005: ID 05d8:8117 Ultima Electronics Corp. [/code][code]antillar@antillar-MS-1656:/usr/share/dvb/atsc$ So, it seems that the tuner is being detected, but the light on it does not turn on? Not sure what is going on? sudo lspci [sudo] password for antillar: 00:00.0 Host bridge: Intel Corporation Core Processor DRAM Controller (rev 02) 00:01.0 PCI bridge: Intel Corporation Core Processor PCI Express x16 Root Port (rev 02) 00:1a.0 USB Controller: Intel Corporation 5 Series/3400 Series Chipset USB2 Enhanced Host Controller (rev 05) 00:1b.0 Audio device: Intel Corporation 5 Series/3400 Series Chipset High Definition Audio (rev 05) 00:1c.0 PCI bridge: Intel Corporation 5 Series/3400 Series Chipset PCI Express Root Port 1 (rev 05) 00:1c.1 PCI bridge: Intel Corporation 5 Series/3400 Series Chipset PCI Express Root Port 2 (rev 05) 00:1c.2 PCI bridge: Intel Corporation 5 Series/3400 Series Chipset PCI Express Root Port 3 (rev 05) 00:1c.4 PCI bridge: Intel Corporation 5 Series/3400 Series Chipset PCI Express Root Port 5 (rev 05) 00:1d.0 USB Controller: Intel Corporation 5 Series/3400 Series Chipset USB2 Enhanced Host Controller (rev 05) 00:1e.0 PCI bridge: Intel Corporation 82801 Mobile PCI Bridge (rev a5) 00:1f.0 ISA bridge: Intel Corporation Mobile 5 Series Chipset LPC Interface Controller (rev 05) 00:1f.2 SATA controller: Intel Corporation 5 Series/3400 Series Chipset 4 port SATA AHCI Controller (rev 05) 00:1f.3 SMBus: Intel Corporation 5 Series/3400 Series Chipset SMBus Controller (rev 05) 01:00.0 VGA compatible controller: ATI Technologies Inc Broadway PRO [Mobility Radeon HD 5800 Series] 01:00.1 Audio device: ATI Technologies Inc Juniper HDMI Audio [Radeon HD 5700 Series] 02:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller (rev 03) 04:00.0 FireWire (IEEE 1394): JMicron Technology Corp. IEEE 1394 Host Controller 04:00.1 System peripheral: JMicron Technology Corp. SD/MMC Host Controller 04:00.2 SD Host controller: JMicron Technology Corp. Standard SD Host Controller 04:00.3 System peripheral: JMicron Technology Corp. MS Host Controller 04:00.4 System peripheral: JMicron Technology Corp. xD Host Controller 05:00.0 Network controller: Intel Corporation Ultimate N WiFi Link 5300 ff:00.0 Host bridge: Intel Corporation Core Processor QuickPath Architecture Generic Non-core Registers (rev 02) ff:00.1 Host bridge: Intel Corporation Core Processor QuickPath Architecture System Address Decoder (rev 02) ff:02.0 Host bridge: Intel Corporation Core Processor QPI Link 0 (rev 02) ff:02.1 Host bridge: Intel Corporation Core Processor QPI Physical 0 (rev 02) ff:02.2 Host bridge: Intel Corporation Core Processor Reserved (rev 02) ff:02.3 Host bridge: Intel Corporation Core Processor Reserved (rev 02) antillar@antillar-MS-1656:/usr/share/dvb/atsc$ I have been searching for a solution to this all weekend without any luck. I remember reading that ehci_hcd is the problem, but I'm not sure if disabling it is a good idea. I don't want my USB ports to go back to v1.1. Thank you!

    Read the article

< Previous Page | 50 51 52 53 54 55 56 57 58 59 60 61  | Next Page >