Search Results

Search found 6079 results on 244 pages for 'power law'.

Page 54/244 | < Previous Page | 50 51 52 53 54 55 56 57 58 59 60 61  | Next Page >

  • A Knights Tale

    - by Phil Factor
    There are so many lessons to be learned from the story of Knight Capital losing nearly half a billion dollars as a result of a deployment gone wrong. The Knight Capital Group (KCG N) was an American global financial services firm engaging in market making, electronic execution, and institutional sales and trading. According to the recent order (File No.3.15570) against Knight Capital by U.S. Securities and Exchange Commission?, Knight had, for many years used some software which broke up incoming “parent” orders into smaller “child” orders that were then transmitted to various exchanges or trading venues for execution. A tracking ‘cumulative quantity’ function counted the number of ‘child’ orders and stopped the process once the total of child orders matched the ‘parent’ and so the parent order had been completed. Back in the mists of time, some code had been added to it  which was excuted if a particular flag was set. It was called ‘power peg’ and seems to have had a similar design and purpose, but, one guesses, would have shared the same tracking function. This code had been abandoned in 2003, but never deleted. In 2005, The tracking function was moved to an earlier point in the main process. It would seem from the account that, from that point, had that flag ever been set, the old ‘Power Peg’ would have been executed like Godzilla bursting from the ice, making child orders without limit without any tracking function. It wasn’t, presumably because the software that set the flag was removed. In 2012, nearly a decade after ‘Power Peg’ was abandoned, Knight prepared a new module to their software to cope with the imminent Retail Liquidity Program (RLP) for the New York Stock Exchange. By this time, the flag had remained unused and someone made the fateful decision to reuse it, and replace the old ‘power peg’ code with this new RLP code. Had the two actions been done together in a single automated deployment, and the new deployment tested, all would have been well. It wasn’t. To quote… “Beginning on July 27, 2012, Knight deployed the new RLP code in SMARS in stages by placing it on a limited number of servers in SMARS on successive days. During the deployment of the new code, however, one of Knight’s technicians did not copy the new code to one of the eight SMARS computer servers. Knight did not have a second technician review this deployment and no one at Knight realized that the Power Peg code had not been removed from the eighth server, nor the new RLP code added. Knight had no written procedures that required such a review.” (para 15) “On August 1, Knight received orders from broker-dealers whose customers were eligible to participate in the RLP. The seven servers that received the new code processed these orders correctly. However, orders sent with the repurposed flag to the eighth server triggered the defective Power Peg code still present on that server. As a result, this server began sending child orders to certain trading centers for execution. Because the cumulative quantity function had been moved, this server continuously sent child orders, in rapid sequence, for each incoming parent order without regard to the number of share executions Knight had already received from trading centers. Although one part of Knight’s order handling system recognized that the parent orders had been filled, this information was not communicated to SMARS.” (para 16) SMARS routed millions of orders into the market over a 45-minute period, and obtained over 4 million executions in 154 stocks for more than 397 million shares. By the time that Knight stopped sending the orders, Knight had assumed a net long position in 80 stocks of approximately $3.5 billion and a net short position in 74 stocks of approximately $3.15 billion. Knight’s shares dropped more than 20% after traders saw extreme volume spikes in a number of stocks, including preferred shares of Wells Fargo (JWF) and semiconductor company Spansion (CODE). Both stocks, which see roughly 100,000 trade per day, had changed hands more than 4 million times by late morning. Ultimately, Knight lost over $460 million from this wild 45 minutes of trading. Obviously, I’m interested in all this because, at one time, I used to write trading systems for the City of London. Obviously, the US SEC is in a far better position than any of us to work out the failings of Knight’s IT department, and the report makes for painful reading. I can’t help observing, though, that even with the breathtaking mistakes all along the way, that a robust automated deployment process that was ‘all-or-nothing’, and tested from soup to nuts would have prevented the disaster. The report reads like a Greek Tragedy. All the way along one wants to shout ‘No! not that way!’ and ‘Aargh! Don’t do it!’. As the tragedy unfolds, the audience weeps for the players, trapped by a cruel fate. All application development and deployment requires defense in depth. All IT goes wrong occasionally, but if there is a culture of defensive programming throughout, the consequences are usually containable. For financial systems, these defenses are required by statute, and ignored only by the foolish. Knight’s mistakes weren’t made by just one hapless sysadmin, but were progressive errors by an  IT culture spanning at least ten years.  One can spell these out, but I think they’re obvious. One can only hope that the industry studies what happened in detail, learns from the mistakes, and draws the right conclusions.

    Read the article

  • remastersys created Live DVD hangs in "Choose a picture"

    - by eos2012
    I used remastersys to create a Live DVD. Then, I used the Live DVD for the installation on another computer. The installation hung at the "Choose a picture" session. Both the "Back" and "Continue" buttons were disabled. It seemed like the installation was hung. I had to power-cycle the computer and reinstall from the Live DVD again. After the power-cycle, the installation from the Live DVD went successfully. Any idea why the installation hung at the "Choose a picture" session, and how to fix it without power-cycle the computer? Thanks a lot!

    Read the article

  • WIFI card intel r 2200 will not work

    - by Telemarkhero
    I have installed 12.04 on a Fujitsu Siemens Amilo Pro. Wifi card does not work. Have tried various threads but none have the same problem. Think I have the correct firmware but the following comes up: gill@ubuntu:~$ iwconfig lo no wireless extensions. eth1 IEEE 802.11bg ESSID:off/any Mode:Managed Channel:0 Access Point: Not-Associated Bit Rate:0 kb/s Tx-Power=off Sensitivity=8/0 Retry limit:7 RTS thr:off Fragment thr:off Power Management:off Link Quality:0 Signal level:0 Noise level:0 Rx invalid nwid:0 Rx invalid crypt:0 Rx invalid frag:0 Tx excessive retries:0 Invalid misc:0 Missed beacon:0 eth0 no wireless extensions. Also gill@ubuntu:~$ rfkill list all 0: phy0: Wireless LAN Soft blocked: no Hard blocked: yes There is a power switch for wifi but it does not do anything in Ubuntu. Any pointers greatfully received.

    Read the article

  • How do I make a form transparent while keeping the controls fully visible?

    - by Power-Mosfet
    I would like to have a form in which the controls on the form are fully visible but the form itself is invisible. If I change the form's Opacity, this makes both the form and the controls on it semi-transparent, so this doesn't work. I can't do this by setting the form's TransparencyKey, since I have a PictureBox on the form. If the image in the PictureBox happens to contain pixels that match the TransparencyKey, they appear as openings in the form, which I don't want.

    Read the article

  • How do I turn off nVidia high performance mode?

    - by gpen06
    I am new to Ubuntu 11.10 and never touched linux until today. I installed Ubuntu alongside with Windows 7. I have an issue with my laptop overheating and freezing when it uses the high performance GPU graphics mode (hybrid card). It is an easy fix for Windows 7. I simply set the graphics mode manually to the low performance integrated graphics (save power) mode using advanced power settings. In Ubuntu, I'm stumped at how to do this. When using Ubuntu, my laptop is showing the same symptoms as it did without the fix for Windows. I have the nVidia graphics driver installed for Windows which allows me to see which mode I am in. I downloaded it off of my laptop's website (ASUS). They do not offer driver downloads for linux. Screenshot of power settings in Windows 7

    Read the article

  • Ajax page.replace_html problems with partials in Rails

    - by Chris Power
    Hello, I am having a problem with a pretty simple AJAX call in rails. I have a blog-style application and each post has a "like" feature. I want to be able to increment the "like" on each post in the index using AJAX onclick. I got it to work; however, the DOM is a bit tricky here, because no matter what partial its looking at, it will only update the TOP partial. so if I click "like" on post #2, it will update and replace the "likes" on post #1 instead. Code for _post partial: <some code here...> <div id="postcontent"> Posted <%= post.created_at.strftime("%A, %b %d")%> <br /> </div> <div id="postlikes"> <%= link_to_remote 'Like', :url => {:controller => 'posts', :action => 'like_post', :id => post.id}%> <%= post.like %> </div> code for _postlikes partial: <div id="postlikes"> <%= link_to_remote 'Like', :url => {:controller => 'posts', :action => 'like_post', :id => @post.id}%> <%= @post.like %> </div> </div> like_post.rjs code: page.replace_html "postlikes", :partial => "postlikes", :object => @post page.visual_effect :highlight, "postlikes", :duration => 3 So this all works properly for the first "postcontent" div. But this is an index of posts, so if I wanted to updated the second "postcontent" div on the page, it will still replace the html of the first. I understand the problem, I just don't know how to fix it :) Thanks in advance!

    Read the article

  • Shutdown issues on my Dell XPS M1530

    - by CppLearner
    On my Dell XPS M1530 lapttop, I am facing issues with shut-down option after upgrading to 12.04 LTS from 11.10. Sometimes it shutdowns "cleanly". But other times everything goes down but I can still see the power LED glowing (even after removing the power cord). If I keep it like that laptop temperature increases. So finally I opt for "hard shut-down" (i.e. pressing the power button on). Any thoughts what is happening here?. Edit: I just found this link to already reported bug https://bugs.launchpad.net/ubuntu/+source/linux/+bug/987933

    Read the article

  • get a different file name

    - by Power-Mosfet
    Hi, How do i get a different file name on a webserver by requesting the url. for example "file" click url link and get "file.bin" the "file" is located on a webserver by requesting the url, user can download "file.bin" instead of "file" something like (file + .bin)

    Read the article

  • [C#] Startup List

    - by Power-Mosfet
    Hi, How do I gat the the full .exe path ManagementClass mangnmt = new ManagementClass("Win32_StartupCommand"); ManagementObjectCollection mcol = mangnmt.GetInstances(); foreach (ManagementObject strt in mcol) { string[] lv = new String[4]; lv[0] = strt["Caption"].ToString(); lv[1] = strt["Location"].ToString(); lv[2] = strt["Command"].ToString(); lv[3] = strt["Description"].ToString(); listView1.Items.Add(new ListViewItem(lv, 0)); }

    Read the article

  • DoWork of BackgroundWorker is called twice when RunWorkerAsync is called once?

    - by Power-Mosfet
    I have create a backgroundworker in an class it works, but if i call and wait until the end run, call it for the second time it will do the same process twice i thinks there is somthing wrong with bw.DoWork += private void button1_Click(object sender, EventArgs e) { nptest.test.start("null", "null"); } namespace nptest { class test { public static void start(string str, string strb) { if (bw.IsBusy != true) { bw.WorkerSupportsCancellation = true; bw.DoWork += (obj, e) => bw_DoWork(str, strb); bw.RunWorkerCompleted += new RunWorkerCompletedEventHandler(bw_RunWorkerCompleted); bw.RunWorkerAsync(); } } private static BackgroundWorker bw = new BackgroundWorker(); private static void bw_DoWork(string str, string strb) { System.Windows.Forms.MessageBox.Show("initializing BackgroundWorker"); } private static void bw_RunWorkerCompleted(object sender, RunWorkerCompletedEventArgs e) { if ((e.Cancelled == true)) { Console.WriteLine("Canceled"); } else if (!(e.Error == null)) { Console.WriteLine("Error: " + e.Error.Message); } bw.Dispose(); } } }

    Read the article

  • List with items returns empty

    - by Power-Mosfet
    I have created a simple List function but if I Loop through the List it's empty. It should not be! All, thank you for the input. problem solved // List function public class process_hook { public static List<string> pro_hook = list_all_processes(); protected static List<string> list_all_processes() { var list = new List<string>(); foreach (Process i in Process.GetProcesses(".")) { try { foreach (ProcessModule pm in i.Modules) { list.Add(pm.FileName); } } catch { } } return list; } } // call private void button1_Click(object sender, EventArgs e) { foreach (String _list in process_hook.pro_hook) { Console.WriteLine(_list); } }

    Read the article

  • how to open many tabs in chromium but unload/disable inactive/notCurrent ones, releasing memory and cpu?

    - by Aquarius Power
    So I have 50 tabs opened on chromium, but that is using too much memory and some of the CPU. How can I have all those concurrent researches I am doing opened but not clog my machine? I think there should have a way that only the active tab is loaded in memory and running, and all the others should stay closed/unloaded from memory, until I want to look at them... Any extension can do something like that?

    Read the article

  • SOLVED Install MythTV & 11.10 on Lenovo S12 (Intel atom) with wireless

    - by keepitsimpleengineer
    This is how I installed Ubuntu 11.10 and MythTV client on my Lenovo S12 (Intel Atom) laptop and use it using WiFi (see additional notes at end). I did this because the upgrade from 11.04 bricked the laptop. Note that the partitions on the Lenovo standard disk were already in place for this installation. Also note that my LAN is setup for fixed IP addresses. Downloaded and burned 11.10 x86 Desktop Ubuntu CD Connected the power supply cord, LAN wire and the external DVD USB drive. Ran Windows XP and made sure performance level "Performance" was set and "Wireless" was enabled. Booted S12 from CD Disabled Networking from icon on upper left panel icon Edited Connections… "Wired connection 1" ? Set IP address, accepted default netmask and set gateway. Also set DNS server. Good idea to check "Connection Information" here to verify everything's O.K. Selected Install Ubuntu from the initial "Install" window Verified the three items were checked (required disk space available, plugged into a power source, & connected to the Internet) Selected Download updates while installing and third party software. Hit Continue… At wireless selected don't want to connect…WiFi…now. Continue… At Installation type, selected Something else. Continue… At partition tale, selected the ext4 Linux partition, set the mount point as "/", and marked for formatting. Here I selected the main disk (/sda) for installing the boot manager. Continue… Selected or verified my Time zone. Continue… Selected my keyboard layout. Continue… Filled in the who are you fields. Make sure password is required to sign in is checked. Continue… Chose a picture. Continue… I selected import no accounts. Continue… Wait as the Install creeps along. If your screen goes blank, tap the space bar ? apparently the screen saver/power plan does this. There are several progress bars. The longest was "Installing system", and it was the next to the last one. Installation Complete window appears, Restart Now… Wait as it stops, The screen blanks then the message "…remove…media…close tray…press enter" I just unplugged the USB DVD and hit enter… It was disheartening but the screen turned Ubuntu Purple-beige and nothing happened, so I help down the power key until it shut down, the pressed it again and the Grub Boot screen appeared. Select Ubuntu… 25.The screen went blank with the little flashing underscore cursor on it and the disk light would occasionally flash. I hit the enter key and eventuality Ubuntu started. After a somewhat long time the unity desktop appeared. 11.10, unlike earlier versions, retains the connection information. Check this by checking the network icon on the upper left applet panel. Here the touch-pad·mouse quit working and I had to reboot. It takes and extremely long time to boot, sometimes requiring several power off/ power on (cold boot). You can try to get the default network manager to work, but it might not, it didn't on mine for WiFi. Thanks to: Chris at URL here's what to do… disconnect your wired Internet connection. input your wireless information into network manager open a terminal (unity dash, top of icon totem, open, and make sure the ruler&pen icon on the bottom is selected, 2nd from left) type in "terminal". Might be a good idea to drag and drop the terminal icon to the terminal, it's easy to get rid of later. click to open a terminal, and type in: sudo rmmod acer_wmi && echo "blacklist acer_wmi" >> /etc/modprobe.d/blacklist.conf and hit enter. type in your password as asked. if you have correctly entered your WiFi information and you are near your AP, you should connect immediately if not, see the URL above ? you might need to replace "network manager" with "wicd" ? I did with 11.04. Update the new 11.10, in the upper left panel applet weird·gear icon is menu with a line about updating. It's the new way to invoke Update Manager. Your lenovo S12 (intel atom) should now run the new unity Ubuntu. Point your elbow at the ceiling and pat yourself on the back. Installing Mythbuntu Client 24.1 Open mythbuntu.org/repos (I urge you not to directly use Ubuntu Software Center for this) Install Mythbuntu Repos Save the file (in ~/Downloads, the default) Run the file ? it will update your repositories so that you will get the proper installation sources ? it will start Ubuntu Software Center to do this ? Click Install… You will need your password. Debconf window will open, select by making sure check mark is in the little box "Would you like to activate…". Forward… Which version? At the time of writing the current "Stable" version was 24.1, select 0.24.x… Forward… Read the message, then forward… Delete the downloaded file. Install synaptic (unity dash, top of icon totem, open, and make sure the ruler&pen icon on the bottom is selected, 2nd from left) type in "synaptic". Click on the synaptic icon. Ubuntu Software Center will open and allow you to install synaptic package manager. Open Synaptic (unity dash, top of icon totem, open, and make sure the ruler&pen icon on the bottom is selected, 2nd from left) type in "Synaptic". Might be a good idea to drag and drop the terminal icon to the terminal, it's easy to get rid of later. Run synaptic, read the intro, and close the intro window. Type in mythbuntu-control-centre in the Quick filter text box, and then select it "Mark for installation" by clicking on the box next to it's name. Marvel at the additional to be installed items, then select "?Mark"… At the top of the synaptic window click on the "? Apply" button. Marvel at the amount of stuff to be installed, the click on "Apply". When finished, close finished window and synaptic. Open mythbuntu-control-centre (unity dash, top of icon totem, open, and make sure the ruler&pen icon on the bottom is selected, 2nd from left) type in "mythbuntu". Might be a good idea to drag and drop the mythbuntu-control-centre icon to the terminal, it's easy to get rid of later. You can now configure and install the frontend. Go down the icon totem on the right side of the window and click as needed… System roles. ? No Backend, Desktop Frontend, and Ubuntu Desktop. Apply… & Apply changes… & Password… MySQL Configuration ? from backend ? Setup General Alt-N(ext) Alt-N(ext) Stetting Access Setup PIN code: ~~~~ Input Security key and click "Test Connection", if ?, then Apply… & Apply… {note: for some inexplicable reason, control centre hung on this, but when I restarted it, it was set properly} Graphics drivers, When I did this, only the Broadcom wireless driver showed up. I closed without doing anything. Services. I enabled SSH & Samba. Apply… & Apply… Repositories. Asked & Answered. MythExport. Pass, I believe it requires backend on the same system. Proprietary Codec Support. Check to enable, Apply… & Apply… System Updates. No action necessary, will be a part of the Ubuntu update mechanism. Themes and Artwork. For themes, I selected Enable/Update all. Apply… & Apply… Infrared & Startup behavior and Plugins. Defer until you know more. Close software centre. Open mythTV (unity dash, top of icon totem, open, and make sure the ruler&pen icon on the bottom is selected, 2nd from left) type in "mythTV". Might be a good idea to drag and drop the mythTV icon to the terminal, it's easy to get rid of later. Incorrect Group Membership. Fix this by clicking "Yes"… Log out/end. Do this by clicking "Yes"… For my Lenovo S12, I had to manually restart Ubuntu - and still with the very long restart…/no start/cold boot/reboot/pressing the shift key required Open mythTV (unity dash, top of icon totem, open, and make sure the ruler&pen icon on the bottom is selected, 2nd from left) type in "mythTV". Might be a good idea to drag and drop the mythTV icon to the terminal, it's easy to get rid of later. Will open with Select country & language. Do so. then get message with "No", hit "Ok" and arrive at the data base Configuration 1/2 screen. You will need your brackend password, from backend ? Setup General Database Configuration 1/2 Password:~? Enter this Hit Alt-n to go to the next page. Select "Use custom id…", then enter a custom ID, I use the machine's name. Hit finish, and MythTV should start up with all default settings. For the lenovo S12, the first thing you want to do is to set Playback profiles to "Normal". From Setup TV Settings Playback Alt-N(ext) Alt-N(ext) Playback Profiles (3/8) : Change Current Video Playback Profile to "Normal". You can fiddle with this setting later. For the lenovo S12, the second thing is to get the sound going. From Setup General Alt-N(ext) Alt-N(ext) Alt-N(ext) Audio System: The top of the screen is a button title "Scan for audio devices", move the highlight there and press the Space bar. Then Tab down to Audio Output Device: and left-right arrow until "ALSA:hw:Card=Intel,DEV=0" is selected. Then Alt-N(ext) until "Finish". Now you should have sound. You should now have MythTV working nicely on the Lenovo S12 Notes about wireless: Running Lenovo S12 on wireless is demanding on both power and WiFi connection. Best results will be obtained when running on power and wired connection. I run my S12 on wireless, actually two serial connections with two access points, something that is not easy to achieve. Here Mythbuntu client-server (in den) <? wireless link 1 <?office LAN? wireless link 2 <? Lenovo S12 Ubuntu 11.10 The office LAN is fixed IP behind an Untangle firewall router. There is another MythTV client on Ubuntu 10.10 computer in the office (which has always worked well). ProblemMythbuntu\Win7 client hangs with frozen frames, short segment of audio repeating. Hardware Rosewill RNX-G300EX IEEE 802.11b/g PCI Wireless Card on client-server 2 Linksys WRT54GL wireless broadband routers on LAN for link1 and link 2 WRT54GL FirmwareDD-WRT v24-sp2(07/22/09) voip set up to act as an access point. Note? many people advised this was an unworkable scheme, and in probably most cases it will be. Solution? Set up DD-WRT with the following Wireless settings… Basic Channel: Different fixed channels at least 4 difference, I use 6 & 11 Basic Sensitivity Range (ACK timing): 50 MAC filter use filter: Enable, Selected Permit only clients listed to access… Requires adding MAC addresses in "Edit MAC Filter List" This causes the 54GL's to ignore any but the listed MAC address, down side, no "guest" capability. Advanced Basic rate: All Advanced CTS Protection Mode: Off Advanced Frame Burst: Enable Advanced Max associate clients: 4 for client link 2, 1 for client-server link 1 Advanced AP isolation: Enable Advanced Preamble: Short Advanced Afterburner: On Advanced Wireless GUI access: Off Advanced WMM support: Off Other settings: default for supplied firmware. Why I suspect this worked? The 54GL Access Points's with the firmware's setting are set to handle a multiple client, wide area situation. With these mods I reconfigured them for a small area, few client situation, disabling Advanced WMM probably the most important. In addition, the client mythtv when used all other users of its access point are turned off except for a Skype phone. Also, the client-server is set up to allow other connections though it's LAN connection, and these are used to connect the TV and disc players, not used when client is being used.

    Read the article

  • Raspberry Pi entrance signed backed by Umbraco - Part 1

    - by Chris Houston
    Being experts on all things Umbraco, we jumped at the chance to help our client, QV Offices, with their pressing signage predicament. They needed to display a sign in the entrance to their building and approached us for our advice. Of course it had to be electronic: displaying multiple names of their serviced office clients, meeting room bookings and on-the-pulse promotions. But with a winding Victorian staircase and minimal storage space how could the monitor be run, updated and managed? That’s where we came in…Raspberry PiUmbraco CMSAutomatic updatesAutomated monitor of the signPower saving when the screen is not in useMounting the screenThe screen that has been used is a standard LED low energy Full HD screen and has been mounted on the wall using it's VESA mounting points, as the wall is a stud wall we were able to add an access panel behind the screen to feed through the mains, HDMI and sensor cables.The Raspberry Pi is then tucked away out of sight in the main electrical cupboard which just happens to be next to the sign, we had an electrician add a power point inside this cupboard to allow us to power the screen and the Raspberry Pi.Designing the interface and editing the contentAlthough a room sign was the initial requirement from QV Offices, their medium term goal has always been to add online meeting booking to their website and hence we suggested adding information about the current and next day's meetings to the sign that would be pulled directly from their online booking system.We produced the design and built the web page to fit exactly on a 1920 x 1080 screen (Full HD in Portrait)As you would expect all the information can be edited via an Umbraco CMS, they are able to add floors, rooms, clients and virtual clients as well as add meeting bookings to their meeting diary.How we configured the Raspberry PiAfter receiving a new Raspberry Pi we downloaded the latest release of Raspbian operating system and followed the official guide which shows how to copy the OS onto an SD card from a Mac, we then followed the majority of steps on this useful guide: 10 Things to Do After Buying a Raspberry Pi.Installing ChromiumWe chose to use the Chromium web browser which for those who do not know is the open sourced version of Google Chrome. You can install this from the terminal with the following command:sudo apt-get install chromium-browserInstalling UnclutterWe found this little application which automatically hides the mouse pointer, it is used in the script below and is installed using the following command:sudo apt-get install unclutterAuto start Chromium and disabling the screen saver, power saving and mouseWhen the Raspberry Pi has been installed it will not have a keyboard or mouse and hence if their was a power cut we needed it to always boot and re-loaded Chromium with the correct URL.Our preferred command line text editor is Nano and I have assumed you know how to use this editor or will be able to work it out pretty quickly.So using the following command:sudo nano /etc/xdg/lxsession/LXDE/autostartWe then changed the autostart file content to:@lxpanel --profile LXDE@pcmanfm --desktop --profile LXDE@xscreensaver -no-splash@xset s off@xset -dpms@xset s noblank@chromium --kiosk --incognito http://www.qvoffices.com/someURL@unclutter -idle 0The first few commands turn off the screen saver and power saving, we then open Cromium in Kiosk Mode (full screen with no menu etc) and pass in the URL to use (I have changed the URL in this example) We found a useful blog post with the Cromium command line switches.Finally we also open an application called Unclutter which auto hides the mouse after 0 seconds, so you will never see a mouse on the sign.We also had to edit the following file:sudo nano /etc/lightdm/lightdm.confAnd added the following line under the [SeatDefault] section:xserver-command=X -s 0 dpmsRefreshing the screenWe decided to try and add a scheduled task that would trigger Chromium to reload the page, at some point in the future we might well change this to using Javascript to update the content, but for now this works fine.First we installed the XDOTool which enables you to script Keyboard commands:sudo apt-get install xdotoolWe used the Refreshing Chromium Browser by Shell Script post as a reference and created the following shell script (which we called refreshing.sh):export DISPLAY=":0"WID=$(xdotool search --onlyvisible --class chromium|head -1)xdotool windowactivate ${WID}xdotool key ctrl+F5This selects the correct display and then sends a CTRL + F5 to refresh Chromium.You will need to give this file execute permissions:chmod a=rwx refreshing.shNow we have the script file setup we just need to schedule it to call this script periodically which is done by using Crontab, to edit this you use the following command:crontab -eAnd we added the following:*/5 * * * * DISPLAY=":.0" /home/pi/scripts/refreshing.sh >/home/pi/cronlog.log 2>&1This calls our script every 5 minutes to refresh the display and it logs any errors to the cronlog.log file.SummaryQV Offices now have a richer and more manageable booking system than they did before we started, and a great new sign to boot.How could we make sure that the sign was running smoothly downstairs in a busy office centre? A second post will follow outlining exactly how Vizioz enabled QV Offices to monitor their sign simply and remotely, from the comfort of their desks.

    Read the article

  • Sun Fire X4800 M2 Posts World Record x86 SPECjEnterprise2010 Result

    - by Brian
    Oracle's Sun Fire X4800 M2 using the Intel Xeon E7-8870 processor and Sun Fire X4470 M2 using the Intel Xeon E7-4870 processor, produced a world record single application server SPECjEnterprise2010 benchmark result of 27,150.05 SPECjEnterprise2010 EjOPS. The Sun Fire X4800 M2 server ran the application tier and the Sun Fire X4470 M2 server was used for the database tier. The Sun Fire X4800 M2 server demonstrated 63% better performance compared to IBM P780 server result of 16,646.34 SPECjEnterprise2010 EjOPS. The Sun Fire X4800 M2 server demonstrated 4% better performance than the Cisco UCS B440 M2 result, both results used the same number of processors. This result used Oracle WebLogic Server 12c, Java HotSpot(TM) 64-Bit Server 1.7.0_02, and Oracle Database 11g. This result was produced using Oracle Linux. Performance Landscape Complete benchmark results are at the SPEC website, SPECjEnterprise2010 Results. The table below compares against the best results from IBM and Cisco. SPECjEnterprise2010 Performance Chart as of 3/12/2012 Submitter EjOPS* Application Server Database Server Oracle 27,150.05 1x Sun Fire X4800 M2 8x 2.4 GHz Intel Xeon E7-8870 Oracle WebLogic 12c 1x Sun Fire X4470 M2 4x 2.4 GHz Intel Xeon E7-4870 Oracle Database 11g (11.2.0.2) Cisco 26,118.67 2x UCS B440 M2 Blade Server 4x 2.4 GHz Intel Xeon E7-4870 Oracle WebLogic 11g (10.3.5) 1x UCS C460 M2 Blade Server 4x 2.4 GHz Intel Xeon E7-4870 Oracle Database 11g (11.2.0.2) IBM 16,646.34 1x IBM Power 780 8x 3.86 GHz POWER 7 WebSphere Application Server V7 1x IBM Power 750 Express 4x 3.55 GHz POWER 7 IBM DB2 9.7 Workgroup Server Edition FP3a * SPECjEnterprise2010 EjOPS, bigger is better. Configuration Summary Application Server: 1 x Sun Fire X4800 M2 8 x 2.4 GHz Intel Xeon processor E7-8870 256 GB memory 4 x 10 GbE NIC 2 x FC HBA Oracle Linux 5 Update 6 Oracle WebLogic Server 11g Release 1 (10.3.5) Java HotSpot(TM) 64-Bit Server VM on Linux, version 1.7.0_02 (Java SE 7 Update 2) Database Server: 1 x Sun Fire X4470 M2 4 x 2.4 GHz Intel Xeon E7-4870 512 GB memory 4 x 10 GbE NIC 2 x FC HBA 2 x Sun StorageTek 2540 M2 4 x Sun Fire X4270 M2 4 x Sun Storage F5100 Flash Array Oracle Linux 5 Update 6 Oracle Database 11g Enterprise Edition Release 11.2.0.2 Benchmark Description SPECjEnterprise2010 is the third generation of the SPEC organization's J2EE end-to-end industry standard benchmark application. The SPECjEnterprise2010 benchmark has been designed and developed to cover the Java EE 5 specification's significantly expanded and simplified programming model, highlighting the major features used by developers in the industry today. This provides a real world workload driving the Application Server's implementation of the Java EE specification to its maximum potential and allowing maximum stressing of the underlying hardware and software systems. The workload consists of an end to end web based order processing domain, an RMI and Web Services driven manufacturing domain and a supply chain model utilizing document based Web Services. The application is a collection of Java classes, Java Servlets, Java Server Pages, Enterprise Java Beans, Java Persistence Entities (pojo's) and Message Driven Beans. The SPECjEnterprise2010 benchmark heavily exercises all parts of the underlying infrastructure that make up the application environment, including hardware, JVM software, database software, JDBC drivers, and the system network. The primary metric of the SPECjEnterprise2010 benchmark is jEnterprise Operations Per Second ("SPECjEnterprise2010 EjOPS"). This metric is calculated by adding the metrics of the Dealership Management Application in the Dealer Domain and the Manufacturing Application in the Manufacturing Domain. There is no price/performance metric in this benchmark. Key Points and Best Practices Sixteen Oracle WebLogic server instances were started using numactl, binding 2 instances per chip. Eight Oracle database listener processes were started, binding 2 instances per chip using taskset. Additional tuning information is in the report at http://spec.org. See Also Oracle Press Release -- SPECjEnterprise2010 Results Page Sun Fire X4800 M2 Server oracle.com OTN Sun Fire X4270 M2 Server oracle.com OTN Sun Storage 2540-M2 Array oracle.com OTN Oracle Linux oracle.com OTN Oracle Database 11g Release 2 Enterprise Edition oracle.com OTN WebLogic Suite oracle.com OTN Disclosure Statement SPEC and the benchmark name SPECjEnterprise are registered trademarks of the Standard Performance Evaluation Corporation. Sun Fire X4800 M2, 27,150.05 SPECjEnterprise2010 EjOPS; IBM Power 780, 16,646.34 SPECjEnterprise2010 EjOPS; Cisco UCS B440 M2, 26,118.67 SPECjEnterprise2010 EjOPS. Results from www.spec.org as of 3/27/2012.

    Read the article

  • Visual Studio Little Wonders: Quick Launch / Quick Access

    - by James Michael Hare
    Once again, in this series of posts I look at features of Visual Studio that may seem trivial, but can help improve your efficiency as a developer. The index of all my past little wonders posts can be found here. Well, my friends, this post will be a bit short because I’m in the middle of a bit of a move at the moment.  But, that said, I didn’t want to let the blog go completely silent this week, so I decided to add another Little Wonder to the list for the Visual Studio IDE. How often have you wanted to change an option or execute a command in Visual Studio, but can’t remember where the darn thing is in the menu, settings, etc.?  If so, Quick Launch in VS2012 (or Quick Access in VS2010 with the Productivity Power Tools extension) is just for you! Quick Launch / Quick Access – find a command or option quickly For those of you using Visual Studio 2012, Quick Launch is built right into the IDE at the top of the title bar, near the minimize, maximize, and close buttons: But do not despair if you are using Visual Studio 2010, you can get Quick Access from the Productivity Power Tools extension.  To do this, you can go to the extension manager: And then go to the gallery and search for Productivity Power Tools and install it.  If you don’t have VS2012 yet, then the Productivity Power Tools is the next best thing.  This extension updates VS2010 with features such as Quick Access, the Solution Navigator, searchable Add Reference Dialog, better tab wells, etc.  I highly recommend it! But back to the topic at hand!  In VS2012 Quick Launch is built into the IDE and can be accessed by clicking in the Quick Launch area of the title bar, or by pressing CTRL+Q.  If you have VS2010 with the PPT installed, though, it is called Quick Access and is accessible through View –> Quick Access: Regardless of which IDE you are using, the feature behaves mostly the same.  It allows you to search all of Visual Studio’s commands and options for a particular topic.  For example, let’s say you want to change from tabs to tabs expanded to spaces, but don’t remember where that option is buried.  You can bring up Quick Launch / Quick Access and type in “tabs”: And it brings up a list of all options on tabs, you can then choose the one appropriate to you and click on it and it will take you right there! A lot easier than diving through the options tree to find what you are looking for!  It also works on menu commands, for example if you can’t remember how to open the Output window: It shows you the menu items that will get you to the Output window, and (if applicable) the keyboard shortcuts.  Again, clicking on one of these will perform the action for you as well. There are also some tasks you can perform directly from Quick Launch / Quick Access.  For example, perhaps you are one of those people who like to have the line numbers in your editor (I do), so let’s bring up Quick Launch / Quick Access and type “line numbers”: And let’s select Turn Line Numbers On, and now our editor looks like: And Voila!  We have line numbers in VS2010.  You can do this in VS2012 too, but it takes you to the option settings instead of directly turning them off and on.  There are bound to be differences between the way the two editors organize settings and commands, but you get the point. So, as you can see, the Quick Launch / Quick Access feature in Visual Studio makes it easy to jump right to the options, commands, or tasks you are interested in without all the digging. Summary An IDE as powerful as Visual Studio has so many options and commands that it can be confusing to remember how to find and invoke them.  Quick Launch (Quick Access in VS2010 with Productivity Power Tools extension) is a quick and handy way to jump to any of these options, commands, or tasks quickly without having to remember in what menu or screen they are buried!  Technorati Tags: C#,CSharp,.NET,Little Wonders,Visual Studio,Quick Access,Quick Launch

    Read the article

  • Cannot Mount USB 3.0 Hard Disk ?!!

    - by Tenken
    Hi, I have a USB 3.0 external hard disk which I am unable to mount. The entry appears in the "lsusb" command, but I do not exactly understand how to mount it. This is the output for my lsusb command. "ASMedia Technology Inc." is the USB 3.0 device. I would appreciate some help in mounting and accessing the hard disk. This the relevant output of my "lsusb -v" : Bus 009 Device 002: ID 174c:5106 ASMedia Technology Inc. Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 2.10 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 idVendor 0x174c ASMedia Technology Inc. idProduct 0x5106 bcdDevice 0.01 iManufacturer 2 ASMedia iProduct 3 AS2105 iSerial 1 00000000000000000000 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 32 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xc0 Self Powered MaxPower 0mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 2 bInterfaceClass 8 Mass Storage bInterfaceSubClass 6 SCSI bInterfaceProtocol 80 Bulk (Zip) iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x02 EP 2 OUT bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0200 1x 512 bytes bInterval 0 Device Qualifier (for other device speed): bLength 10 bDescriptorType 6 bcdUSB 2.10 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 64 bNumConfigurations 1 Device Status: 0x0001 Self Powered Bus 009 Device 001: ID 1d6b:0003 Linux Foundation 3.0 root hub Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 3.00 bDeviceClass 9 Hub bDeviceSubClass 0 Unused bDeviceProtocol 3 bMaxPacketSize0 9 idVendor 0x1d6b Linux Foundation idProduct 0x0003 3.0 root hub bcdDevice 2.06 iManufacturer 3 Linux 2.6.35-28-generic xhci_hcd iProduct 2 xHCI Host Controller iSerial 1 0000:04:00.0 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 25 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xe0 Self Powered Remote Wakeup MaxPower 0mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 9 Hub bInterfaceSubClass 0 Unused bInterfaceProtocol 0 Full speed (or root) hub iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0004 1x 4 bytes bInterval 12 Hub Descriptor: bLength 9 bDescriptorType 41 nNbrPorts 4 wHubCharacteristic 0x0009 Per-port power switching Per-port overcurrent protection TT think time 8 FS bits bPwrOn2PwrGood 10 * 2 milli seconds bHubContrCurrent 0 milli Ampere DeviceRemovable 0x00 PortPwrCtrlMask 0xff Hub Port Status: Port 1: 0000.0100 power Port 2: 0000.0100 power Port 3: 0000.0503 highspeed power enable connect Port 4: 0000.0503 highspeed power enable connect Device Status: 0x0003 Self Powered Remote Wakeup Enabled This is the error given when I try to mount the hard drive: shinso@shinso-IdeaPad:~$ sudo mount /dev/sdb /mnt [sudo] password for shinso: mount: /dev/sdb: unknown device This the output of "dmesg|tail": [30062.774178] Either the lower file is not in a valid eCryptfs format, or the key could not be retrieved. Plaintext passthrough mode is not enabled; returning -EIO [30535.800977] usb 9-4: USB disconnect, address 3 [30659.237342] Valid eCryptfs headers not found in file header region or xattr region [30659.237351] Either the lower file is not in a valid eCryptfs format, or the key could not be retrieved. Plaintext passthrough mode is not enabled; returning -EIO [31259.268310] Valid eCryptfs headers not found in file header region or xattr region [31259.268313] Either the lower file is not in a valid eCryptfs format, or the key could not be retrieved. Plaintext passthrough mode is not enabled; returning -EIO [31860.059058] Valid eCryptfs headers not found in file header region or xattr region [31860.059062] Either the lower file is not in a valid eCryptfs format, or the key could not be retrieved. Plaintext passthrough mode is not enabled; returning -EIO [32465.220590] Valid eCryptfs headers not found in file header region or xattr region [32465.220593] Either the lower file is not in a valid eCryptfs format, or the key could not be retrieved. Plaintext passthrough mode is not enabled; returning -EIO I am using Ubuntu 10.10 (64 bit). Any help is appreciated.

    Read the article

  • The Best Data Integration for Exadata Comes from Oracle

    - by maria costanzo
    Oracle Data Integrator and Oracle GoldenGate offer unique and optimized data integration solutions for Oracle Exadata. For example, customers that choose to feed their data warehouse or reporting database with near real-time throughout the day, can do so without decreasing  performance or availability of source and target systems. And if you ask why real-time, the short answer is: in today’s fast-paced, always-on world, business decisions need to use more relevant, timely data to be able to act fast and seize opportunities. A longer response to "why real-time" question can be found in a related blog post. If we look at the solution architecture, as shown on the diagram below,  Oracle Data Integrator and Oracle GoldenGate are both uniquely designed to take full advantage of the power of the database and to eliminate unnecessary middle-tier components. Oracle Data Integrator (ODI) is the best bulk data loading solution for Exadata. ODI is the only ETL platform that can leverage the full power of Exadata, integrate directly on the Exadata machine without any additional hardware, and by far provides the simplest setup and fastest overall performance on an Exadata system. We regularly see customers achieving a 5-10 times boost when they move their ETL to ODI on Exadata. For  some companies the performance gain is even much higher. For example a large insurance company did a proof of concept comparing ODI vs a traditional ETL tool (one of the market leaders) on Exadata. The same process that was taking 5hrs and 11 minutes to complete using the competing ETL product took 7 minutes and 20 seconds with ODI. Oracle Data Integrator was 42 times faster than the conventional ETL when running on Exadata.This shows that Oracle's own data integration offering helps you to gain the most out of your Exadata investment with a truly optimized solution. GoldenGate is the best solution for streaming data from heterogeneous sources into Exadata in real time. Oracle GoldenGate can also be used together with Data Integrator for hybrid use cases that also demand non-invasive capture, high-speed real time replication. Oracle GoldenGate enables real-time data feeds from heterogeneous sources non-invasively, and delivers to the staging area on the target Exadata system. ODI runs directly on Exadata to use the database engine power to perform in-database transformations. Enterprise Data Quality is integrated with Oracle Data integrator and enables ODI to load trusted data into the data warehouse tables. Only Oracle can offer all these technical benefits wrapped into a single intelligence data warehouse solution that runs on Exadata. Compared to traditional ETL with add-on CDC this solution offers: §  Non-invasive data capture from heterogeneous sources and avoids any performance impact on source §  No mid-tier; set based transformations use database power §  Mini-batches throughout the day –or- bulk processing nightly which means maximum availability for the DW §  Integrated solution with Enterprise Data Quality enables leveraging trusted data in the data warehouse In addition to Starwood Hotels and Resorts, Morrison Supermarkets, United Kingdom’s fourth-largest food retailer, has seen the power of this solution for their new BI platform and shared their story with us. Morrisons needed to analyze data across a large number of manufacturing, warehousing, retail, and financial applications with the goal to achieve single view into operations for improved customer service. The retailer deployed Oracle GoldenGate and Oracle Data Integrator to bring new data into Oracle Exadata in near real-time and replicate the data into reporting structures within the data warehouse—extending visibility into operations. Using Oracle's data integration offering for Exadata, Morrisons produced financial reports in seconds, rather than minutes, and improved staff productivity and agility. You can read more about Morrison’s success story here and hear from Starwood here. From an Irem Radzik article.

    Read the article

  • AI to move custom-shaped spaceships (shape affecting movement behaviour)

    - by kaoD
    I'm designing a networked turn based 3D-6DOF space fleet combat strategy game which relies heavily on ship customization. Let me explain the game a bit, since you need to know a bit about it to set the question. What I aim for is the ability to create your own fleet of ships with custom shapes and attached modules (propellers, tractor beams...) which would give advantages and disadvantages to each ship, so you have lots of different fleet distributions. E.g., long ship with two propellers at the side would let the ship spin around that plane easily, bigger ships would move slowly unless you place lots of propellers at the back (therefore spending more "construction" points and energy when moving, and it will only move fast towards that direction.) I plan to balance all the game around this feature. The game would revolve around two phases: orders and combat phase. During the orders phase, you command the different ships. When all players finish the order phase, the combat phase begins and the ship orders get resolved in real-time for some time, then the action pauses and there's a new orders phase. The problem comes when I think about player input. To move a ship, you need to turn on or off different propellers if you want to steer, travel forward, brake, rotate in place... These propellers don't have to work at their whole power, so you can achieve more movement combinations with less propellers. I think this approach is a bit boring. The player doesn't want to fiddle with motors or anything, you just want to MOVE and KILL. The way I intend the player to give orders to these ships is by a destination and a rotation, and then the AI would calculate the correct propeller power to achive that movement and rotation. Propulsion doesn't have to be the same throught the entire turn calculation (after the orders have been given) so it would be cool if the ships reacted as they move, adjusting the power of the propellers for their needs dynamically, but it may be too hard to implement and it's not really needed for the game to work. In both cases, how would that AI decide which propellers to activate for the best (or at least not worst) trajectory to be achieved? I though about some approaches: Learning AI: The ship types would learn about their movement by trial and error, adjusting their behaviour with more uses, and finally becoming "smart". I don't want to get involved THAT far in AI coding, and I think it can be frustrating for the player (even if you can let it learn without playing.) Pre-calculated timestep movement: Upon ship creation, ALL possible movements are calculated for each propeller configuration and power for a given delta-time. Memory intensive, ugly, bad. Pre-calculated trajectories: The same as above but not for each delta-time but the whole trajectory, which would then be fitted as much as possible. Requires a fixed propeller configuration for the whole combat phase and is still memory intensive, ugly and bad. Continuous brute forcing: The AI continously checks ALL possible propeller configurations throughout the entire combat phase, precalculates a few time steps and decides which is the best one based on that. Con: what's good now might not be that good later, and it's too CPU intensive, ugly, and bad too. Single brute forcing: Same as above, but only brute forcing at the beginning of the simulation, so it needs constant propeller configuration throughout the entire combat phase. Coninuous angle check: This is not a full movement method, but maybe a way to discard "stupid" propeller configurations. Given the current propeller's normal vector and the final one, you can approximate the power needed for the propeller based on the angle. You must do this continuously throughout the whole combat phase. I figured this one out recently so I didn't put in too much thought. A priori, it has the "what's good now might not be that good later" drawback too, and it doesn't care about the other propellers which may act together to make a better propelling configuration. I'm really stuck here. Any ideas?

    Read the article

  • Failing Sata HDD

    - by DaveCol
    I think my HDD is fried... Could someone confirm or help me restore it? I was using Hardware RAID 1 Configuration [2 x 160GB SATA HDD] on a CentOS 4 Installation. All of a sudden I started seeing bad sectors on the second HDD which stopped being mirrored. I have removed the RAID array and have tested with SMART which showed the following error: 187 Unknown_Attribute 0x003a 001 001 051 Old_age Always FAILING_NOW 4645 I have no clue what this means, or if I can recover from it. Could someone give me some ideas on how to fix this, or what HDD to get to replace this? Complete SMART report: Smartctl version 5.33 [i686-redhat-linux-gnu] Copyright (C) 2002-4 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: GB0160CAABV Serial Number: 6RX58NAA Firmware Version: HPG1 User Capacity: 160,041,885,696 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 7 ATA Standard is: ATA/ATAPI-7 T13 1532D revision 4a Local Time is: Tue Oct 19 13:42:42 2010 COT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED See vendor-specific Attribute list for marginal Attributes. General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 433) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 54) minutes. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 100 253 006 Pre-fail Always - 0 3 Spin_Up_Time 0x0002 097 097 000 Old_age Always - 0 4 Start_Stop_Count 0x0033 100 100 020 Pre-fail Always - 152 5 Reallocated_Sector_Ct 0x0033 095 095 036 Pre-fail Always - 214 7 Seek_Error_Rate 0x000f 078 060 030 Pre-fail Always - 73109713 9 Power_On_Hours 0x0032 083 083 000 Old_age Always - 15133 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0033 100 100 020 Pre-fail Always - 154 184 Unknown_Attribute 0x0032 038 038 000 Old_age Always - 62 187 Unknown_Attribute 0x003a 001 001 051 Old_age Always FAILING_NOW 4645 189 Unknown_Attribute 0x0022 100 100 000 Old_age Always - 0 190 Unknown_Attribute 0x001a 061 055 000 Old_age Always - 656408615 194 Temperature_Celsius 0x0000 039 045 000 Old_age Offline - 39 (Lifetime Min/Max 0/22) 195 Hardware_ECC_Recovered 0x0032 070 059 000 Old_age Always - 12605265 197 Current_Pending_Sector 0x0000 100 100 000 Old_age Offline - 1 198 Offline_Uncorrectable 0x0000 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0000 200 200 000 Old_age Offline - 62 SMART Error Log Version: 1 ATA Error Count: 4645 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 4645 occurred at disk power-on lifetime: 15132 hours (630 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 7b 86 b1 ea Error: UNC at LBA = 0x0ab1867b = 179406459 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 02 7b 86 b1 ea 00 00:38:52.796 READ DMA ec 03 45 00 00 00 a0 00 00:38:52.796 IDENTIFY DEVICE ef 03 45 00 00 00 a0 00 00:38:52.794 SET FEATURES [Set transfer mode] ec 00 00 7b 86 b1 a0 00 00:38:49.991 IDENTIFY DEVICE c8 00 04 79 86 b1 ea 00 00:38:49.935 READ DMA Error 4644 occurred at disk power-on lifetime: 15132 hours (630 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 7b 86 b1 ea Error: UNC at LBA = 0x0ab1867b = 179406459 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 04 79 86 b1 ea 00 00:38:41.517 READ DMA ec 03 45 00 00 00 a0 00 00:38:41.515 IDENTIFY DEVICE ef 03 45 00 00 00 a0 00 00:38:41.515 SET FEATURES [Set transfer mode] ec 00 00 7b 86 b1 a0 00 00:38:49.991 IDENTIFY DEVICE c8 00 06 77 86 b1 ea 00 00:38:49.935 READ DMA Error 4643 occurred at disk power-on lifetime: 15132 hours (630 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 7b 86 b1 ea Error: UNC at LBA = 0x0ab1867b = 179406459 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 06 77 86 b1 ea 00 00:38:41.517 READ DMA ec 03 45 00 00 00 a0 00 00:38:41.515 IDENTIFY DEVICE ef 03 45 00 00 00 a0 00 00:38:41.515 SET FEATURES [Set transfer mode] ec 00 00 7b 86 b1 a0 00 00:38:41.513 IDENTIFY DEVICE c8 00 06 77 86 b1 ea 00 00:38:38.706 READ DMA Error 4642 occurred at disk power-on lifetime: 15132 hours (630 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 7b 86 b1 ea Error: UNC at LBA = 0x0ab1867b = 179406459 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 06 77 86 b1 ea 00 00:38:41.517 READ DMA ec 03 45 00 00 00 a0 00 00:38:41.515 IDENTIFY DEVICE ef 03 45 00 00 00 a0 00 00:38:41.515 SET FEATURES [Set transfer mode] ec 00 00 7b 86 b1 a0 00 00:38:41.513 IDENTIFY DEVICE c8 00 06 77 86 b1 ea 00 00:38:38.706 READ DMA Error 4641 occurred at disk power-on lifetime: 15132 hours (630 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 7b 86 b1 ea Error: UNC at LBA = 0x0ab1867b = 179406459 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 06 77 86 b1 ea 00 00:38:41.517 READ DMA ec 03 45 00 00 00 a0 00 00:38:41.515 IDENTIFY DEVICE ef 03 45 00 00 00 a0 00 00:38:41.515 SET FEATURES [Set transfer mode] ec 00 00 7b 86 b1 a0 00 00:38:41.513 IDENTIFY DEVICE c8 00 06 77 86 b1 ea 00 00:38:38.706 READ DMA SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 15131 - # 2 Short offline Completed without error 00% 15131 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.

    Read the article

  • Hard Disk DRDY error: is it a crash

    - by pranjal
    I am using IBM Thinkpad, 1.7GHz, 512 RAM with Linux Mint 9 installed. I have two partitions in addition to root. One of the partitions became read-only yesterday, after which I rebooted my system. It is extremely slow along with DRDY Error : Is my Hard disk crashed ? Error Log while booting. Differences between boot sector and its backup. failed command : READ DMA BMDMA : stat 0X25 ata 1.00 : status : { DRDY ERR } ata 1.00 : status :{ UNC } Buffer I/O error on logical device, logical block 65467 smartctl output for the partition: mint mint # smartctl -a /dev/sda1 smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: TOSHIBA MK4026GAX RoHS Serial Number: X5LY1623T Firmware Version: PA107E User Capacity: 40,007,761,920 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 6 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Thu Feb 17 06:48:25 2011 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x84) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 153) seconds. Offline data collection capabilities: (0x1b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. No General Purpose Logging support. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 30) minutes. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0 2 Throughput_Performance 0x0005 100 100 050 Pre-fail Offline - 0 3 Spin_Up_Time 0x0027 100 100 001 Pre-fail Always - 310 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 3968 5 Reallocated_Sector_Ct 0x0033 100 100 050 Pre-fail Always - 40 7 Seek_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0 8 Seek_Time_Performance 0x0005 100 100 050 Pre-fail Offline - 0 9 Power_On_Hours 0x0032 082 082 000 Old_age Always - 7257 10 Spin_Retry_Count 0x0033 179 100 030 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 3484 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 489 193 Load_Cycle_Count 0x0032 064 064 000 Old_age Always - 367150 194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 36 (Lifetime Min/Max 14/57) 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 33 197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 82 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 1 199 UDMA_CRC_Error_Count 0x0032 200 253 000 Old_age Always - 0 220 Disk_Shift 0x0002 100 100 000 Old_age Always - 101 222 Loaded_Hours 0x0032 085 085 000 Old_age Always - 6146 223 Load_Retry_Count 0x0032 100 100 000 Old_age Always - 0 224 Load_Friction 0x0022 100 100 000 Old_age Always - 0 226 Load-in_Time 0x0026 100 100 000 Old_age Always - 227 240 Head_Flying_Hours 0x0001 100 100 001 Pre-fail Offline - 0 SMART Error Log Version: 1 ATA Error Count: 2371 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 2371 occurred at disk power-on lifetime: 7256 hours (302 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 05 1a 1b 00 e0 Error: UNC 5 sectors at LBA = 0x00001b1a = 6938 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 05 1a 1b 00 e0 00 00:03:10.061 READ DMA f8 00 00 00 00 00 e0 00 00:03:10.061 READ NATIVE MAX ADDRESS ec 00 00 00 00 00 a0 02 00:03:10.053 IDENTIFY DEVICE ef 03 45 00 00 00 a0 02 00:03:10.053 SET FEATURES [Set transfer mode] f8 00 00 00 00 00 e0 00 00:03:10.053 READ NATIVE MAX ADDRESS Error 2370 occurred at disk power-on lifetime: 7256 hours (302 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 05 1a 1b 00 e0 Error: UNC 5 sectors at LBA = 0x00001b1a = 6938 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 05 1a 1b 00 e0 00 00:03:03.328 READ DMA f8 00 00 00 00 00 e0 00 00:03:03.327 READ NATIVE MAX ADDRESS ec 00 00 00 00 00 a0 02 00:03:03.320 IDENTIFY DEVICE ef 03 45 00 00 00 a0 02 00:03:03.319 SET FEATURES [Set transfer mode] f8 00 00 00 00 00 e0 00 00:03:03.319 READ NATIVE MAX ADDRESS Error 2369 occurred at disk power-on lifetime: 7256 hours (302 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 05 1a 1b 00 e0 Error: UNC 5 sectors at LBA = 0x00001b1a = 6938 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 05 1a 1b 00 e0 00 00:02:56.582 READ DMA f8 00 00 00 00 00 e0 00 00:02:56.582 READ NATIVE MAX ADDRESS ec 00 00 00 00 00 a0 02 00:02:56.574 IDENTIFY DEVICE ef 03 45 00 00 00 a0 02 00:02:56.574 SET FEATURES [Set transfer mode] f8 00 00 00 00 00 e0 00 00:02:56.574 READ NATIVE MAX ADDRESS Error 2368 occurred at disk power-on lifetime: 7256 hours (302 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 05 1a 1b 00 e0 Error: UNC 5 sectors at LBA = 0x00001b1a = 6938 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 05 1a 1b 00 e0 00 00:02:49.809 READ DMA f8 00 00 00 00 00 e0 00 00:02:49.809 READ NATIVE MAX ADDRESS ec 00 00 00 00 00 a0 02 00:02:49.801 IDENTIFY DEVICE ef 03 45 00 00 00 a0 02 00:02:49.801 SET FEATURES [Set transfer mode] f8 00 00 00 00 00 e0 00 00:02:49.801 READ NATIVE MAX ADDRESS Error 2367 occurred at disk power-on lifetime: 7256 hours (302 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 05 1a 1b 00 e0 Error: UNC 5 sectors at LBA = 0x00001b1a = 6938 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 05 1a 1b 00 e0 00 00:02:43.056 READ DMA f8 00 00 00 00 00 e0 00 00:02:43.056 READ NATIVE MAX ADDRESS ec 00 00 00 00 00 a0 02 00:02:43.048 IDENTIFY DEVICE ef 03 45 00 00 00 a0 02 00:02:43.048 SET FEATURES [Set transfer mode] f8 00 00 00 00 00 e0 00 00:02:43.047 READ NATIVE MAX ADDRESS SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] Device does not support Selective Self Tests/Logging Do I need to get a new Hard Disk my PC ?

    Read the article

< Previous Page | 50 51 52 53 54 55 56 57 58 59 60 61  | Next Page >