Search Results

Search found 16445 results on 658 pages for 'array initialization'.

Page 551/658 | < Previous Page | 547 548 549 550 551 552 553 554 555 556 557 558  | Next Page >

  • Uploadify Flash Uploader and Random UPLOAD_ERR_CANT_WRITE errors

    - by dcneiner
    I am using Uploadify to provide progress bar support for file uploads on a PHP app I built. It works perfectly for a few uploads,then every few uploads it fails and the data from the $_FILES array reveals an UPLOAD_ERR_CANT_WRITE error. (Error code 7). I ran Paros proxy between my browser and the server to see the difference between a passing and failing request. The only difference was the content separator for the multi-part post which changes every time. I would conclude this was fully a server error, except with a plain jane form, I cannot reproduce the error. I am not a server guy, so please let me know what information is needed to troubleshoot this and I will update the question with those details. I did place these lines in the .htaccess, but to know avail. The site is hosted on Rackspace Cloudsites so my configuration options are limited: <IfModule mod_security.c> SecFilterEngine Off SecFilterScanPOST Off </IfModule> php_value upload_max_filesize 10M php_value post_max_size 10M php_value max_execution_time 200 php_value max_input_time 200

    Read the article

  • RAID 5 - DELL 2850 and others

    - by Kiara
    I have installed Ubuntu on a DELL 2850 and I have configured an array of 5 disks (SCSI 73GB 10K) in RAID5. I wanted to simulate a drive error so in the middle of something I just took one of the drives out and put it back again after a bit. Then the drive shows an orange light and seems to be rebuilding but actually is taking hours and hours with no results. So I went to the PERC utility (Ctrl+M) and the disk shows "REBLD". But it never gets to an online state. So I went to Objects - Physical drives - Rebuilding - View rebuild process. And in here I can see a bar moving from 0%... but if I reboot before finishing and get into the PERC Utility again, it seems to start again rebuilding from 0% - so it is not rebuilding automatically. My concern is: what would happen in a real situation? Do I have to just switch the server off and go to the Perc utility to start the rebuilding manually? I thought the whole point was to have this done automatically and without the need of stopping the server. Or does it perhaps rebuild automatically indeed but needs to have enough time without rebooting because otherwise the rebuilding process will start from scratch? It seems to take more than 3h for a 73gb disk! My second question is: can I mix then hard drives? So if I have a RAID of 5x73GB 10K can I use different size (146GB) or speeds (15K)? Apparently someone said it is OK in here Poweredge 2850: replace disk with larger in RAID?

    Read the article

  • Move database from SQL Server 2012 to 2008

    - by Rich
    I have a database on a SQL Sever 2012 instance which I would like to copy to a 2008 server. The 2008 server cannot restore backups created by a 2012 server (I have tried). I cannot find any options in 2012 to create a 2008 compatible backup. Am I missing something? Is there an easy way to export the schema and data to a version-agnostic format which I can then import into 2008? The database does not use any 2012 specific features. It contains tables, data and stored procedures. Here is what I have tried so far: I tried "tasks" - "generate scripts" on the 2012 server, and I was able to generate the schema (including stored procedures) as a sql script. This didn't include any of the data, though. After creating that schema on my 2008 machine, I was able to open the "Export Data" wizard on the 2012 machine, and after configuring the 2012 as source machine and the 2008 as target machine, I was presented with a list of tables which I could copy. I selected all my tables (300+), and clicked through the wizard. Unfortunately it spends ages generating its scripts, then fails with errors like "Failure inserting into the read-only column 'FOO_ID'". I also tried the "Copy Database Wizard", which claimed to be able to copy "from 2000 or later to 2005 or later". It has two modes: 1) "detach and attach", which failed with error: Message: Index was outside the bounds of the array. StackTrace: at Microsoft.SqlServer.Management.Smo.PropertyBag.SetValue(Int32 index, Object value) ... at Microsoft.SqlServer.Management.Smo.DataFile.get_FileName() 2) SQL Management Object Method which failed with error "Cannot read property IsFileStream.This property is not available on SQL Server 7.0."

    Read the article

  • Outbound HTTP performance tuning recommendations

    - by Richard Gadsden
    I'll detail my exact setup below, but general recommendations for a better web-browsing experience will be useful. A nice checklist of things to try would be great! I have 600 users on a single site with an 8MB leased line. I get a lot of moans about the performance of "the internet" (ie web-browsing). What recommendations do the community have for speeding things up without just throwing more bandwidth at it? I expect I will end up buying some more, but good management tips are always valuable. My setup is this: Cisco PIX (515E) firewall on the edge of the network. It's just doing some basic NAT, and opening up a handful of ports to various bastion hosts (aka DMZ servers). The DMZ is just a switch that the servers are plugged into. ISA 2006 Enterprise array (two servers) connecting DMZ to the internal LAN, with WebSense Web Security filtering HTTP traffic so users can't look at porn or waste bandwidth on YouTube during working hours. I've done a few things - I've just switched my internal DNS over to use root hints, which halved DNS query latency from 500ms to 250ms. Well worth doing. I'm trying to cache more aggressively, but so much more of the internet is AJAXy and doesn't cache very well as compared to five years ago. Plus the 70GB of cache which felt like a lot a few years ago really isn't any more. I'm getting about 45% cache hits by number of requests, but only about 22% by size, ie larger objects are less likely to be cached. Latency seems to be part of the problem. Is that attributable to the bandwidth problem, or are there things I can look at to try to reduce latency even on heavily-loaded bandwidth?

    Read the article

  • NVidia ION and /dev/mapper/nvidia_... issues.

    - by Ritsaert Hornstra
    I have an NVidia ION board with 4 SATA ports and want to use that to run a Linux Server (CentOS 5.4). I first hooed up 3 HDs (that will be a RAID5 array) and a forth small boot HD. I first started to use the onboard RAID capability but that does not work correctly under Linux: the raid capacity is not a real RAID but uses lvm to define some arays. After setting the BIOS back to normal SATA mode and whiping the HDs, the first boot harddisk (/dev/sda) is seen as /dev/sda BEFORE mounting and after mounting as /dev/mapper/nvidia_. CentOS is unable to install on it (and grub is not installable on it either). So somehow the harddisk is still seen as if it belongs to some lvm volume. I tried to clean out the HD by issuing a few dd if=/dev/zero of=/dev/sda commands to wipe the starting cylinders and final cylinders but to no avail. Did anyone see this problem and did anyone find a solution? UPDATE When I create only a single ext3 partition on the first HD (/dev/mapper/nvidia_...) no LVM partitions are seen and I can boot from /dev/mapper/nvidia_.... Now the next step is to see how I can get rid of this folly.

    Read the article

  • Can't get an IBM xSeries 345 server to load Windows Server 2003 using ServerGuide utility

    - by Kyle Noland
    I have a client that has an IBM xSeries 345 eServer. Per the IBM support website, I have downloaded the ServerGuide Setup 7.4.17 installation ISO and burned a bootable CD. The CD boots fine and loads the utility. I walk through the following screens without any issue: Set the date and Time Detect the IBM ServeRAID card and install the latest firmware Clear the hard disks Set up the RAID array The next step is format the NOS partition. I select my partition size and the utility goes through the following steps: Creating NOS partition Formatting NOS partition (NTFS) Copying W32 files The copying W32 files takes about 10 minutes. I see the CD drive and disks working hard. When the copying is complete, I'm taken to a blank page just NOS Partitioning at the top. At the bottom of the screen are the familiar Back and Exit buttons. I see the place where the Next button should be, and if I click on it I can tell there is something there, but the space is empty. No button is displayed and clicking the empty spot doesn't ever take me to the next screen. I can't load the OS until I get past this part. I have already tried: Burning multiple copies and versions of the ServerGuide CD Letting the final screen just sit there over the weekend thinking it might advance after syncing the drives or something Has anybody else seen this? I'm really at a loss here. EDIT: I found another person who has the exact same problem as me: http://www.ibm.com/developerworks/forums/thread.jspa?messageID=14451763

    Read the article

  • JAWStats statspath error on windows

    - by crosenblum
    I have AWStats which works fine, and JAWStats I am trying to get working. I have tried back and forward slashes to get the program to read the dirdata files. I even moved the folder of dirdata outside of program files folder, in case it had problems with folder names with spaces in them. Here is my config file. // core config parameters $sConfigDefaultView = "thismonth.all"; $bConfigChangeSites = true; $bConfigUpdateSites = true; $sUpdateSiteFilename = "xml_update.php"; // individual site configuration // awstats092012.noname.jumpingcrab.com.txt $aConfig["site1"] = array( "statspath" => "C:\\Program Files\\AWStats\\DirData\\", "statsname" => "awstats[MM][YYYY].yourexample.com.txt", "updatepath" => "C:\\Program Files\\AWStats\\wwwroot\\cgi-bin\\awstats.pl\\", "siteurl" => "http://yourexample.com", "theme" => "default", "fadespeed" => 250, "password" => "", "includes" => "" ); Domain names changed to protect the innocent...:P Here is the error message: An error has occured: No AWStats Log Files Found JAWStats cannot find any AWStats log files in the specified directory: C:\Program Files\AWStats\DirData\ Is this the correct folder? Is your config name, site1, correct? Please refer to the installation instructions for more information.

    Read the article

  • ZFS: Mirror vs. RAID-Z

    - by John Clayton
    I'm planning on building a file server using OpenSolaris and ZFS that will provide two primary services - be an iSCSI target for XenServer virtual machines & be a general home file server. The hardware I'm looking at includes 2x 4-port SATA controllers, 2x small boot drives (one on each controller), and 4x big drives for storage. This allows one free port per controller for upgrading the array down the road. Where I'm a little confused is how to setup the storage drives. For performance, mirroring appears to be king. I'm having a hard time seeing what the benefit would be of using RAIDZ over mirroring would be. With this setup I can see two options - two mirrored pools in one stripe, or RAIDZ2. Both should protect against 2 drive failures, and/or one controller failure...the only benefit of RAIDZ2 would be that any 2 drives could fail. The storage should be 50% of capacity in both cases, but the first should have much better performance, right? The other thing I'm trying to wrap my mind around is the benefit of mirrored arrays with more than two devices. For data integrity what, if any, would be the benefit of a RAIDZ over a three-way mirror? Since ZFS maintains file integrity what does RAIDZ bring to the table...doesn't ZFS's integrity checks negate the value of RAIDZ's parity?

    Read the article

  • Unable to authenticate to Windows Server 2003 for file browsing as non-administrator user.

    - by Fopedush
    I've got a windows server 2003 box containing a raid 5 array I use for mass storage. I want to set up a special non-administrator account that can be used to browse files over the network, with only read access. Ideally I'll map my network drive as this user to avoid accidentally hosing my data, and mount as an administrator user on occasions where I actually need write access. I've created a non-administrator user on the Windows Server box (called "ReadOnly)", and granted the user read permissions on the folders I need. However, when I try to browse to the files, and authenticate as this user, I'm told "Permission denied". If I throw the readOnly user into the administrators group, however, I can authenticate and browse just fine. I am, of course, only attempting to browse to folder for which I have given this user read permissions. Obviously my ReadOnly user is missing some privilege here, but I can't figure out what it is. I've been digging around in group policy editor all day to no avail. What am I missing? Fake Edit: I'm doing my browsing from a Windows 7 box, but I don't think that is relevant.

    Read the article

  • Repairing inconsistent pages in database

    - by Raj
    We have a SQL 2000 DB. The server crashed due to Raid array failure. Now when we run DBCC CHECKDB, we get an error that there are 27 consistency errors in 9 pages. When we run DBCC PAGE on these pages, we get this: Msg 8939, Level 16, State 106, Line 1 Table error: Object ID 1397580017, index ID 2, page (1:8404521). Test (m_freeCnt == freeCnt) failed. Values are 2 and 19. Msg 8939, Level 16, State 108, Line 1 Table error: Object ID 1397580017, index ID 2, page (1:8404521). Test (emptySlotCnt == 0) failed. Values are 1 and 0. Since the indicated index is non-clustered and is created by a unique constarint that includes 2 columns, we tried dropping and recreating the index. This resulted in the following error: CREATE UNIQUE INDEX terminated because a duplicate key was found for index ID 2. Most significant primary key is '3280'. The statement has been terminated. However running Select var_id,result_on from tests group by var_id,result_on having count(*)>1 returns 0 rows. Here is what we are planning to do: Restore a pre-server crash copy of the DB and run DBCC CHECKDB If that returns clean, then restore again with no recovery Apply all subequent TLOG backups Stop production app, take a tail log backup and apply that too Drop prod DB and rename the freshly restored DB to make it prod Start prod app Could someone please punch holes in this approach? Maybe, suggest a different approach? What we need is minimum downtime. SQL 2000 DB Size 94 GB The table that has corrupt pages has 460 Million+ rows of data Thanks for the help. Raj

    Read the article

  • Where do I connect the HDD LED wires on my RAID adapter?

    - by Giffyguy
    I'm using a Promise FastTrak TX8660 with RAID 5. The manual (and Google) just doesn't seem to explain how exactly to connect a standard two-pin HDD LED wire to the eight available pins on the card. The Manual just says - To connect your LED, follow the following diagram: The card itself resembles the diagram: But it doesn't make any sense to me. All I have is a two-pin connecter for HDD LED on the front of my computer case. I don't need anything fancy like the fault LED or seperate indicators for each drive. I just want to be able to see when my RAID 5 array is working, that's all. I don't know what the "R" and "G" stand for, but my HDD LED wires are red and white. I tried connecting the red wire to the "R" pin and the white wire to the "G" pin, but that just makes the LED on the front of my case light up indefinitely, even when the computer is idle. Which pins am I suppose to connect the HDD LED header to for basic activity indication?

    Read the article

  • Why my VPN doesn't work anymore?

    - by xx77aBs
    I have openvpn server running on debian lenny. There is only one client - and it is running Windows 7 64-bit. This has worked for few months without any problems. And now, let's say for the last 7 days, it doesn't work at all. I connect successfully from client to the server, but I can't access anything through VPN. I have set it up so that all internet traffic is routed through VPN, and now when I connect with the client, the client can't do anything on the net (open any webpage, ping google, anything ...). Can you help me to figure out what's wrong ? I don't know where to start. I've also tried to connect to another openvpn server (I've installed and configured openvpn on another server, and when I try to connect to it result is the same). So I think there's something wrong with client ... Here is my connection log: Wed Apr 04 21:35:59 2012 OpenVPN 2.3-alpha1 Win32-MSVC++ [SSL (OpenSSL)] [LZO2] [PF_INET6] [IPv6 payload 20110522-1 (2.2.0)] built on Feb 21 2012 Enter Management Password: Wed Apr 04 21:35:59 2012 MANAGEMENT: TCP Socket listening on [AF_INET]127.0.0.10:25340 Wed Apr 04 21:35:59 2012 Need hold release from management interface, waiting... Wed Apr 04 21:36:00 2012 MANAGEMENT: Client connected from [AF_INET]127.0.0.10:25340 Wed Apr 04 21:36:00 2012 MANAGEMENT: CMD 'state on' Wed Apr 04 21:36:00 2012 MANAGEMENT: CMD 'log all on' Wed Apr 04 21:36:00 2012 MANAGEMENT: CMD 'hold off' Wed Apr 04 21:36:00 2012 MANAGEMENT: CMD 'hold release' Wed Apr 04 21:36:00 2012 WARNING: No server certificate verification method has been enabled. See http://openvpn.net/howto.html#mitm for more info. Wed Apr 04 21:36:00 2012 NOTE: OpenVPN 2.1 requires '--script-security 2' or higher to call user-defined scripts or executables Wed Apr 04 21:36:00 2012 Socket Buffers: R=[8192->8192] S=[8192->8192] Wed Apr 04 21:36:00 2012 MANAGEMENT: >STATE:1333568160,RESOLVE,,, Wed Apr 04 21:36:00 2012 UDPv4 link local: [undef] Wed Apr 04 21:36:00 2012 UDPv4 link remote: [AF_INET]11.22.33.44:1234 Wed Apr 04 21:36:00 2012 MANAGEMENT: >STATE:1333568160,WAIT,,, Wed Apr 04 21:36:00 2012 MANAGEMENT: >STATE:1333568160,AUTH,,, Wed Apr 04 21:36:00 2012 TLS: Initial packet from [AF_INET]11.22.33.44:1234, sid=ee329574 f15e9e04 Wed Apr 04 21:36:00 2012 VERIFY OK: depth=1, C=US, ST=CA, L=SanFrancisco, O=Fort-Funston, CN=Fort-Funston CA, [email protected] Wed Apr 04 21:36:00 2012 VERIFY OK: depth=0, C=US, ST=CA, L=SanFrancisco, O=Fort-Funston, CN=server_key, [email protected] Wed Apr 04 21:36:01 2012 Data Channel Encrypt: Cipher 'BF-CBC' initialized with 128 bit key Wed Apr 04 21:36:01 2012 Data Channel Encrypt: Using 160 bit message hash 'SHA1' for HMAC authentication Wed Apr 04 21:36:01 2012 Data Channel Decrypt: Cipher 'BF-CBC' initialized with 128 bit key Wed Apr 04 21:36:01 2012 Data Channel Decrypt: Using 160 bit message hash 'SHA1' for HMAC authentication Wed Apr 04 21:36:01 2012 Control Channel: TLSv1, cipher TLSv1/SSLv3 DHE-RSA-AES256-SHA, 1024 bit RSA Wed Apr 04 21:36:01 2012 [server_key] Peer Connection Initiated with [AF_INET]11.22.33.44:1234 Wed Apr 04 21:36:02 2012 MANAGEMENT: >STATE:1333568162,GET_CONFIG,,, Wed Apr 04 21:36:03 2012 SENT CONTROL [server_key]: 'PUSH_REQUEST' (status=1) Wed Apr 04 21:36:03 2012 PUSH: Received control message: 'PUSH_REPLY,redirect-gateway def1,route 172.16.100.1,topology net30,ping 10,ping-restart 120,ifconfig 172.16.100.6 172.16.100.5' Wed Apr 04 21:36:03 2012 OPTIONS IMPORT: timers and/or timeouts modified Wed Apr 04 21:36:03 2012 OPTIONS IMPORT: --ifconfig/up options modified Wed Apr 04 21:36:03 2012 OPTIONS IMPORT: route options modified Wed Apr 04 21:36:03 2012 ROUTE_GATEWAY 192.168.1.1/255.255.255.0 I=15 HWADDR=00:1f:1f:3f:61:55 Wed Apr 04 21:36:03 2012 do_ifconfig, tt->ipv6=0, tt->did_ifconfig_ipv6_setup=0 Wed Apr 04 21:36:03 2012 MANAGEMENT: >STATE:1333568163,ASSIGN_IP,,172.16.100.6, Wed Apr 04 21:36:03 2012 open_tun, tt->ipv6=0 Wed Apr 04 21:36:03 2012 TAP-WIN32 device [VPN] opened: \\.\Global\{E28FD52B-F6C3-4094-A36A-30CB02FAC7E8}.tap Wed Apr 04 21:36:03 2012 TAP-Win32 Driver Version 9.9 Wed Apr 04 21:36:03 2012 Notified TAP-Win32 driver to set a DHCP IP/netmask of 172.16.100.6/255.255.255.252 on interface {E28FD52B-F6C3-4094-A36A-30CB02FAC7E8} [DHCP-serv: 172.16.100.5, lease-time: 31536000] Wed Apr 04 21:36:03 2012 Successful ARP Flush on interface [31] {E28FD52B-F6C3-4094-A36A-30CB02FAC7E8} Wed Apr 04 21:36:08 2012 TEST ROUTES: 2/2 succeeded len=1 ret=1 a=0 u/d=up Wed Apr 04 21:36:08 2012 C:\Windows\system32\route.exe ADD 11.22.33.44 MASK 255.255.255.255 192.168.1.1 Wed Apr 04 21:36:08 2012 ROUTE: CreateIpForwardEntry succeeded with dwForwardMetric1=25 and dwForwardType=4 Wed Apr 04 21:36:08 2012 Route addition via IPAPI succeeded [adaptive] Wed Apr 04 21:36:08 2012 C:\Windows\system32\route.exe ADD 0.0.0.0 MASK 128.0.0.0 172.16.100.5 Wed Apr 04 21:36:08 2012 ROUTE: CreateIpForwardEntry succeeded with dwForwardMetric1=30 and dwForwardType=4 Wed Apr 04 21:36:08 2012 Route addition via IPAPI succeeded [adaptive] Wed Apr 04 21:36:08 2012 C:\Windows\system32\route.exe ADD 128.0.0.0 MASK 128.0.0.0 172.16.100.5 Wed Apr 04 21:36:08 2012 ROUTE: CreateIpForwardEntry succeeded with dwForwardMetric1=30 and dwForwardType=4 Wed Apr 04 21:36:08 2012 Route addition via IPAPI succeeded [adaptive] Wed Apr 04 21:36:08 2012 MANAGEMENT: >STATE:1333568168,ADD_ROUTES,,, Wed Apr 04 21:36:08 2012 C:\Windows\system32\route.exe ADD 172.16.100.1 MASK 255.255.255.255 172.16.100.5 Wed Apr 04 21:36:08 2012 ROUTE: CreateIpForwardEntry succeeded with dwForwardMetric1=30 and dwForwardType=4 Wed Apr 04 21:36:08 2012 Route addition via IPAPI succeeded [adaptive] Wed Apr 04 21:36:08 2012 Initialization Sequence Completed Wed Apr 04 21:36:08 2012 MANAGEMENT: >STATE:1333568168,CONNECTED,SUCCESS,172.16.100.6,11.22.33.44 Client's route table after connection with OpenVPN: IPv4 Route Table =========================================================================== Active Routes: Network Destination Netmask Gateway Interface Metric 0.0.0.0 0.0.0.0 192.168.1.1 192.168.1.41 281 0.0.0.0 128.0.0.0 172.16.100.1 172.16.100.6 31 94.23.53.45 255.255.255.255 192.168.1.1 192.168.1.41 25 127.0.0.0 255.0.0.0 On-link 127.0.0.1 306 127.0.0.1 255.255.255.255 On-link 127.0.0.1 306 127.255.255.255 255.255.255.255 On-link 127.0.0.1 306 128.0.0.0 128.0.0.0 172.16.100.1 172.16.100.6 31 172.16.100.4 255.255.255.252 On-link 172.16.100.6 286 172.16.100.6 255.255.255.255 On-link 172.16.100.6 286 172.16.100.7 255.255.255.255 On-link 172.16.100.6 286 192.168.1.0 255.255.255.0 On-link 192.168.1.41 281 192.168.1.41 255.255.255.255 On-link 192.168.1.41 281 192.168.1.255 255.255.255.255 On-link 192.168.1.41 281 224.0.0.0 240.0.0.0 On-link 127.0.0.1 306 224.0.0.0 240.0.0.0 On-link 192.168.1.41 281 224.0.0.0 240.0.0.0 On-link 172.16.100.6 286 255.255.255.255 255.255.255.255 On-link 127.0.0.1 306 255.255.255.255 255.255.255.255 On-link 192.168.1.41 281 255.255.255.255 255.255.255.255 On-link 172.16.100.6 286 =========================================================================== Persistent Routes: Network Address Netmask Gateway Address Metric 0.0.0.0 0.0.0.0 192.168.1.1 Default =========================================================================== IPv6 Route Table =========================================================================== Active Routes: If Metric Network Destination Gateway 13 58 ::/0 On-link 1 306 ::1/128 On-link 13 58 2001::/32 On-link 13 306 2001:0:5ef5:79fd:3cc3:6b9:ac7c:14db/128 On-link 15 281 fe80::/64 On-link 31 286 fe80::/64 On-link 13 306 fe80::/64 On-link 13 306 fe80::3cc3:6b9:ac7c:14db/128 On-link 31 286 fe80::7d72:9515:7213:35e3/128 On-link 15 281 fe80::9cec:ce3f:89de:a123/128 On-link 1 306 ff00::/8 On-link 13 306 ff00::/8 On-link 15 281 ff00::/8 On-link 31 286 ff00::/8 On-link =========================================================================== Persistent Routes: None

    Read the article

  • Are HDMI to VGA Adapters Really Device-Specific?

    - by allquixotic
    There are a lot of devices on the market right now (especially mobile devices) with a Micro-HDMI or Mini-HDMI port and no VGA or D-Sub output. Most manufacturers of said devices sell a cable that looks something like this: I have yet to find a cable like this that claims to work on a wide array of devices. In general, these cables claim to work with one specific device only. The way these cables work, I think, is that analog VGA signals are sent from the HDMI port on the device. This should work for devices that have special hardware on the motherboard/GPU capable of driving this. Is it the case that these cables have to be custom designed for each device? Or, is it rather that any device which possesses this special "signaling of analog VGA over the HDMI port" can be made to work with a cable that is physically compatible (i.e. the HDMI end plugs into the device and the VGA end accepts a VGA monitor cable)? Note that I am not looking for a product recommendation, just a conceptual clarification on what exactly these devices are doing. Also, a few remarks: The cables like the one depicted here are not digital to analog converters. I know about these: they are expensive, and they are the ONLY solution if your device only outputs a digital signal and is incapable of driving analog VGA over the HDMI port. The cables like the one depicted here are not straight crossover cables from VGA to HDMI, either. The crossover cables are designed to send a digital HDMI signal over the VGA port's wires; that is, the wire protocol is HDMI (digital) but the physical pinout is the same as VGA, even though nothing analog is happening. Once again, this is not the behavior that, I believe, the devices which I'm talking about in this question are doing. The cabling and devices that this question is about transmit the analog VGA data over the HDMI port (the HDMI port is in the device outputting the data, and the VGA side is the monitor/projector).

    Read the article

  • 24TB RAID 6 configuration

    - by Phil
    I am in charge of a new website in a niche industry that stores lots of data (10+ TB per client, growing to 2 or 3 clients soon). We are considering ordering about $5000 worth of 3TB drives (10 in a RAID 6 configuration and 10 for backup), which will give us approximately 24 TB of production storage. The data will be written once and remain unmodified for the lifetime of the website, so we only need to do a backup one time. I understand basic RAID theory, however I am not experienced with it. My question is, does this sound like a good configuration? What potential problems could this setup cause? Also, what is the best way to do a one-time backup? Have two RAID 6 arrays, one for offsite backup and one for production? Or should I backup the RAID 6 production array to a JBOD? EDIT: The data server is running Windows 2008 Server x64. EDIT 2: To reduce rebuild time, what would you think about using two RAID 5's instead of one RAID 6?

    Read the article

  • Can't get an IBM xSeries 345 server to load Windows Server 2003 using ServerGuide utility

    - by Kyle Noland
    I have a client that has an IBM xSeries 345 eServer. Per the IBM support website, I have downloaded the ServerGuide Setup 7.4.17 installation ISO and burned a bootable CD. The CD boots fine and loads the utility. I walk through the following screens without any issue: Set the date and Time Detect the IBM ServeRAID card and install the latest firmware Clear the hard disks Set up the RAID array The next step is format the NOS partition. I select my partition size and the utility goes through the following steps: Creating NOS partition Formatting NOS partition (NTFS) Copying W32 files The copying W32 files takes about 10 minutes. I see the CD drive and disks working hard. When the copying is complete, I'm taken to a blank page just NOS Partitioning at the top. At the bottom of the screen are the familiar Back and Exit buttons. I see the place where the Next button should be, and if I click on it I can tell there is something there, but the space is empty. No button is displayed and clicking the empty spot doesn't ever take me to the next screen. I can't load the OS until I get past this part. I have already tried: Burning multiple copies and versions of the ServerGuide CD Letting the final screen just sit there over the weekend thinking it might advance after syncing the drives or something Has anybody else seen this? I'm really at a loss here.

    Read the article

  • Does a 3ware "ECC-ERROR" matter on a JBOD when I have ZFS?

    - by Stefan Lasiewski
    I have a FreeBSD 8.x machine running ZFS and with a 3ware 9690SA controller. The 3ware controller shows an ECC-ERROR with one of the disks: //host> /c0 show VPort Status Unit Size Type Phy Encl-Slot Model ------------------------------------------------------------------------------ p0 OK u0 279.39 GB SAS 0 - SEAGATE ST3300657SS p1 OK u0 279.39 GB SAS 1 - SEAGATE ST3300657SS p2 OK u1 931.51 GB SAS 2 - SEAGATE ST31000640SS p3 ECC-ERROR u2 931.51 GB SAS 3 - SEAGATE ST31000640SS p4 OK u3 931.51 GB SAS 4 - SEAGATE ST31000640SS /c0 show events shows no ECC errors in it's recent history. ZFS does not currently detect any errors. zpool status says No known data errors My question: Is this ECC-ERROR something that I need to be concerned about? According to the 3ware CLI 9.5.2 Manual, an ECC-ERROR means that the 3ware controller caught a read-error for one or more sectors on this drive. This sometimes occurs when a RAID array is recovering from a failed disk. I believe that ECC-ERRORS can also be detected when the 3ware Controller verifies each disk. None of the drives have failed and thus there was no drive rebuild, so I assume that 3ware discovered a bad sector when it ran it's weekly auto-verify scan of the disks. Is this a safe assumption? According to our logs, ZFS has not detected any bad sectors on this drive. ZFS can work around read errors -- if ZFS detects a bad sector on the drive, it will simply mark that sector as bad and never use it again. From the ZFS perspective one bad sector isn't a big deal, although it might indicate that the drive is starting to go bad.

    Read the article

  • How to let hard drive sleep in RAID1 configuration?

    - by Al Kepp
    Normally in Windows 7 a hard drive stops spinning when it is not used for a longer while. This can be configured in Windows and I use it on computers which are turned on 24/7 but not used much often. My problem is on a computer with Intel X79 chipset with an integrated RAID controller. There is Windows 7 installed on an SSD drive, and there is RAID1 array with two SATA HDD drives for data. Those SATA drives aren't used much so I'd like to let them sleep (i.e stop spinning). But they ignore settings in Windows. How to let them sleep when using RAID1? It seems to me that those drives are "unstoppable", they are spinning 24/7 even when they aren't used at all. Maybe they would behave normally if I used Windows-based software RAID, but I use hardware RAID controller. Is there a way to let them stop spinning and sleep after for example 3 or 5 hours of inactivity (i.e. the same way as they would behave in Windows without RAID)?

    Read the article

  • Using smartctl to get vendor specific Attributes from ssd drive behind a SmartArray P410 controller

    - by Lairsdragon
    Recently I have deployed some HP server with SSD's behind a SmartArray P410 controller. While not official supported from HP the server work well sofar. Now I like to get wear level info's, error statistics etc from the drive. While the SA P410 supports a passthru of the SMART Command to a single drive in the array the output I was not able to the the interesting things from the drive. In this case especially the value the Wear level indicator is from interest for me (Attr.ID 233), but this is ony present if the drive is directly attanched to a SATA Controller. smartctl on directly connected ssd: # smartctl -A /dev/sda smartctl version 5.38 [x86_64-unknown-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF READ SMART DATA SECTION === SMART Attributes Data Structure revision number: 5 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 3 Spin_Up_Time 0x0000 100 000 000 Old_age Offline In_the_past 0 4 Start_Stop_Count 0x0000 100 000 000 Old_age Offline In_the_past 0 5 Reallocated_Sector_Ct 0x0002 100 100 000 Old_age Always - 0 9 Power_On_Hours 0x0002 100 100 000 Old_age Always - 8561 12 Power_Cycle_Count 0x0002 100 100 000 Old_age Always - 55 192 Power-Off_Retract_Count 0x0002 100 100 000 Old_age Always - 29 232 Unknown_Attribute 0x0003 100 100 010 Pre-fail Always - 0 233 Unknown_Attribute 0x0002 088 088 000 Old_age Always - 0 225 Load_Cycle_Count 0x0000 198 198 000 Old_age Offline - 508509 226 Load-in_Time 0x0002 255 000 000 Old_age Always In_the_past 0 227 Torq-amp_Count 0x0002 000 000 000 Old_age Always FAILING_NOW 0 228 Power-off_Retract_Count 0x0002 000 000 000 Old_age Always FAILING_NOW 0 smartctl on P410 connected ssd: # ./smartctl -A -d cciss,0 /dev/cciss/c1d0 smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net (Right, it is complety empty) smartctl on P410 connected hdd: # ./smartctl -A -d cciss,0 /dev/cciss/c0d0 smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net Current Drive Temperature: 27 C Drive Trip Temperature: 68 C Vendor (Seagate) cache information Blocks sent to initiator = 1871654030 Blocks received from initiator = 1360012929 Blocks read from cache and sent to initiator = 2178203797 Number of read and write commands whose size <= segment size = 46052239 Number of read and write commands whose size > segment size = 0 Vendor (Seagate/Hitachi) factory information number of hours powered up = 3363.25 number of minutes until next internal SMART test = 12 Do I hunt here a bug, or is this a limitation of the p410 SMART cmd Passthru?

    Read the article

  • Very poor SCSI hd performance on IBM x336 with LSI 1030 RAID1

    - by David Tschoepe
    I'm experiencing very poor performance on an IBM x336 server with dual 73GB 15k hard drives on a U320 controller, LSI 1030. We're getting maybe 3.5MB/sec max (per HD Tune utility). It should be over 100MB/sec at least, I would think (another x335 box is running 70-80MB/sec). The server was recently setup and didn't really notice the problem, but may have been there from the beginning, so not sure. I have installed the IBM ServerRAID Windows utility. The server is running Windows 2008 R2 Web edition (if that matters). I thought maybe one of the drives was bad, so far I have removed one of the drives out of the array and tested again, but still the same results. I'm waiting for the RAID1 to resync and I will try pulling the other drive next. I've also used the ServerRAID utility but haven't noticed anything in there that might indicate a problem. Not sure if I'm on the right path here. So looking for some advice to track this down.

    Read the article

  • Disk IO slow on ESXi, even slower on a VM (freeNAS + iSCSI)

    - by varesa
    I have a server with ESXi 5 and iSCSI attached network storage(4x1Tb Raid-Z on freenas 8.0.4). Those two machines are connected to each other with Gigabit ethernet. The raid-z volume is divided into three parts: two zvols, shared with iscsi, and one directly on top of zfs, shared with nfs and similar. I ssh'd into the freeNAS box, and did some testing on the disks. I used ddto test the third part of the disks (straight on top of ZFS). I copied a 4GB (2x the amount of RAM) block from /dev/zero to the disk, and the speed was 80MB/s. Other of the iSCSI shared zvols is a datastore for the ESXi. I did similar test with time dd .. there. Since the dd there did not give the speed, I divided the amount of data transfered by the time show by time. The result was around 30-40 MB/s. Thats about half of the speed from the freeNAS host! Then I tested the IO on a VM running on the same ESXi host. The VM was a light CentOS 6.0 machine, which was not really doing anything else at that time. There were no other VMs running on the server at the time, and the other two "parts" of the disk array were not used. A similar dd test gave me result of about 15-20 MB/s. That is again about half of the result on a lower level! Of course the is some overhead in raid-z - zfs - zvolume - iSCSI - VMFS - VM, but I don't expect it to be that big. I belive there must be something wrong in my system. I have heard about bad performance of freeNAS's iSCSI, is that it? I have not managed to get any other "big" SAN OS to run on the box (NexentaSTOR, openfiler). Can you see any obvious problems with my setup?

    Read the article

  • RabbitMQ message consumers stop consuming messages

    - by Bruno Thomas
    Hi server fault, Our team is in a spike sprint to choose between ActiveMQ or RabbitMQ. We made 2 little producer/consumer spikes sending an object message with an array of 16 strings, a timestamp, and 2 integers. The spikes are ok on our devs machines (messages are well consumed). Then came the benchs. We first noticed that somtimes, on our machines, when we were sending a lot of messages the consumer was sometimes hanging. It was there, but the messsages were accumulating in the queue. When we went on the bench plateform : cluster of 2 rabbitmq machines 4 cores/3.2Ghz, 4Gb RAM, load balanced by a VIP one to 6 consumers running on the rabbitmq machines, saving the messages in a mysql DB (same type of machine for the DB) 12 producers running on 12 AS machines (tomcat), attacked with jmeter running on another machine. The load is about 600 to 700 http request per second, on the servlets that produces the same load of RabbitMQ messages. We noticed that sometimes, consumers hang (well, they are not blocked, but they dont consume messages anymore). We can see that because each consumer save around 100 msg/sec in database, so when one is stopping consumming, the overall messages saved per seconds in DB fall down with the same ratio (if let say 3 consumers stop, we fall around 600 msg/sec to 300 msg/sec). During that time, the producers are ok, and still produce at the jmeter rate (around 600 msg/sec). The messages are in the queues and taken by the consumers still "alive". We load all the servlets with the producers first, then launch all the consumers one by one, checking if the connexions are ok, then run jmeter. We are sending messages to one direct exchange. All consumers are listening to one persistent queue bounded to the exchange. That point is major for our choice. Have you seen this with rabbitmq, do you have an idea of what is going on ? Thank you for your answers.

    Read the article

  • Is it possible to have a wireless in-house NAS with wireless data transfer rates of equivalent to SATA speeds?

    - by techaddict
    Basically I would like to know, if it is possible to set up an NAS in my house to be accessed wirelessly, that can reach equivalent real-life data transfer speeds to USB 3.0 or an internal SATA hard drive. I have been wanting to do this for some time ( a couple of years now). Basically, this is what I want to do: Plug in a number of hard drives in an array, somewhere in my house, to be left plugged in and never have to be monitored. Ideally several terabytes. Whenever I am home, to have my computer and laptop configured to automatically find the NAS, as easy as plugging in an external hard drive - except completely wirelessly. Data transfer needs to be as seamless and quick as having added another internal hard drive in my laptop. Moreover, data should be able to accessed without having to copy it over - I should be able to wirelessly access the NAS and browse files, and open files directly from the NAS. For example, say I wanted to open a video - I should be able to play the video that is located on the NAS, directly from the NAS, completely wirelessly. If I wanted to open a .pdf file, I should be able to open it and read it directly from the NAS, as if it were located on my physical internal hard drive. Cost is important as well. Please tell me what equipment I need for this to be possible. I know you geniuses out there who can tell me if this is possible.

    Read the article

  • Outlook 2007/2010 autodiscovering old Exchange info

    - by Dan
    I currently have an Exchange setup as follows: two Exchange 2003 servers clustered together set up as the current mailbox stores, one Exchange 2003 setup as a frontend, one Exchange 2007 set up as a frontend (was set up for testing by my predecessor, never really used intentionally), and now four Exchange 2010 servers - two mailboxes in a DAG and two with Hub/CAS. Everything seems to be working fine with one exception - Outlook 2007/2010 clients are still autodiscovering the test 2007 frontend and not the 2010 CAS array. I know this because there's an expired cert on the 2007 box so the client displays a cert error when you attempt to autocreate the outlook profile. From what I've read, there is an SCP (Service Connection Point) in AD that is pointing to the old server and it is getting returned first, causing Outlook to try it first. How can I prevent Outlook from even attempting to connect to this 2007 box from now on? http://www.msexchange.org/articles_tutorials/exchange-server-2010/management-administration/exchange-autodiscover.html When Outlook 2007 is installed on a domain joined workstation then the Outlook client will query Active Directory for the Autodiscover information. Active Directory will return a list of SCP’s and the Outlook client will automatically select the first SCP in this list. Using the information found in the SCP the Outlook client will contact the Client Access Server for its configuration information and the Outlook client will be configured automatically.

    Read the article

  • Why are SMART error rates going down?

    - by Jeff Shattock
    I have a hard drive that's part of a Linux software raid5 array. SMART has reported that its multi_zone_error_rate was 0, then 1, then 3. So I figured I better start backing up more frequently and prepare to replace the drive. Now, today, the multi_zone_error_rate of that very same drive is back down to 1. It seems that 2 errors unhappened while I wasn't looking. I've also seen simliar behaviour by inspecting the syslog on the server. Jun 7 21:01:17 FS1 smartd[25593]: Device: /dev/sdc, SMART Usage Attribute: 7 Seek_Error_Rate changed from 200 to 100 Jun 7 21:01:17 FS1 smartd[25593]: Device: /dev/sde, SMART Usage Attribute: 7 Seek_Error_Rate changed from 200 to 100 Jun 7 21:01:18 FS1 smartd[25593]: Device: /dev/sdg, SMART Usage Attribute: 7 Seek_Error_Rate changed from 200 to 100 Jun 8 02:31:18 FS1 smartd[25593]: Device: /dev/sdg, SMART Usage Attribute: 7 Seek_Error_Rate changed from 100 to 200 Jun 8 03:01:17 FS1 smartd[25593]: Device: /dev/sdc, SMART Usage Attribute: 7 Seek_Error_Rate changed from 100 to 200 Jun 8 03:01:17 FS1 smartd[25593]: Device: /dev/sde, SMART Usage Attribute: 7 Seek_Error_Rate changed from 100 to 200 These are raw values, not the human-useful values that smartctl -a produces, but the behaviour is similar: error rates changing, then undoing the change. None of these are the drive that had the multi_zone weirdness. I haven't seen any problems from the RAID; its most recent scrub ( < 24 hours ago) came back totally clean. The only thing I can think of is that the SMART reporting circuitry on the drive isn't working properly all the time. The cables are in tight on the drive and board. What's going on here?

    Read the article

  • Chrome caching 302 redirects

    - by Thermionix
    I have a php script with is used to rotate banner images on a site. Under Firefox/IE page refreshes will make another request and a different image will be returned. Under Chrome, the request seems to be cached and only opening the page in a new tab will cause it to actually query the script. I believe this used to work in older versions of chrome, I've tried a few different types of redirect codes all with the same result. Any tips? <img class="banner" src="/inc/banner.php" alt=""> ~$ cat /var/www/inc/banner.php <?php header("HTTP/1.1 302 Redirect"); header("Cache-Control: max-age=0, no-cache, no-store, must-revalidate"); //header('HTTP/1.1 307 Temporary Redirect'); //header("expires: none"); //header("expires: max"); //header("Cache-Control: public"); $folder = '../img/banner/'; $exts = 'jpg jpeg png gif'; $files = array(); $i = -1; if ('' == $folder) $folder = './'; $handle = opendir($folder); $exts = explode(' ', $exts); while (false !== ($file = readdir($handle))) { foreach($exts as $ext) { // for each extension check the extension if (preg_match('/\.'.$ext.'$/i', $file, $test)) { // faster than ereg, case insensitive $files[] = $file; // it's good ++$i; } } } closedir($handle); // We're not using it anymore mt_srand((double)microtime()*1000000); // seed for PHP < 4.2 $rand = mt_rand(0, $i); // $i was incremented as we went along header('Location: '.$folder.$files[$rand]); flush(); ?> curl output; ~$ curl -I -k https://example.net/inc/banner.php HTTP/1.1 302 Redirect Server: nginx/1.1.14 Date: Fri, 24 Feb 2012 03:23:46 GMT Content-Type: text/html Connection: keep-alive X-Powered-By: PHP/5.3.10-1ubuntu1 Cache-Control: max-age=0, no-cache, no-store, must-revalidate Location: ../img/banner/2.jpg

    Read the article

< Previous Page | 547 548 549 550 551 552 553 554 555 556 557 558  | Next Page >