Search Results

Search found 14185 results on 568 pages for 'cd drive'.

Page 552/568 | < Previous Page | 548 549 550 551 552 553 554 555 556 557 558 559  | Next Page >

  • DTracing a PHPUnit Test: Looking at Functional Programming

    - by cj
    Here's a quick example of using DTrace Dynamic Tracing to work out what a PHP code base does. I was reading the article Functional Programming in PHP by Patkos Csaba and wondering how efficient this stype of programming is. I thought this would be a good time to fire up DTrace and see what is going on. Since DTrace is "always available" even in production machines (once PHP is compiled with --enable-dtrace), this was easy to do. I have Oracle Linux with the UEK3 kernel and PHP 5.5 with DTrace static probes enabled, as described in DTrace PHP Using Oracle Linux 'playground' Pre-Built Packages I installed the Functional Programming sample code and Sebastian Bergmann's PHPUnit. Although PHPUnit is included in the Functional Programming example, I found it easier to separately download and use its phar file: cd ~/Desktop wget -O master.zip https://github.com/tutsplus/functional-programming-in-php/archive/master.zip wget https://phar.phpunit.de/phpunit.phar unzip master.zip I created a DTrace D script functree.d: #pragma D option quiet self int indent; BEGIN { topfunc = $1; } php$target:::function-entry /copyinstr(arg0) == topfunc/ { self->follow = 1; } php$target:::function-entry /self->follow/ { self->indent += 2; printf("%*s %s%s%s\n", self->indent, "->", arg3?copyinstr(arg3):"", arg4?copyinstr(arg4):"", copyinstr(arg0)); } php$target:::function-return /self->follow/ { printf("%*s %s%s%s\n", self->indent, "<-", arg3?copyinstr(arg3):"", arg4?copyinstr(arg4):"", copyinstr(arg0)); self->indent -= 2; } php$target:::function-return /copyinstr(arg0) == topfunc/ { self->follow = 0; } This prints a PHP script function call tree starting from a given PHP function name. This name is passed as a parameter to DTrace, and assigned to the variable topfunc when the DTrace script starts. With this D script, choose a PHP function that isn't recursive, or modify the script to set self->follow = 0 only when all calls to that function have unwound. From looking at the sample FunSets.php code and its PHPUnit test driver FunSetsTest.php, I settled on one test function to trace: function testUnionContainsAllElements() { ... } I invoked DTrace to trace function calls invoked by this test with # dtrace -s ./functree.d -c 'php phpunit.phar \ /home/cjones/Desktop/functional-programming-in-php-master/FunSets/Tests/FunSetsTest.php' \ '"testUnionContainsAllElements"' The core of this command is a call to PHP to run PHPUnit on the FunSetsTest.php script. Outside that, DTrace is called and the PID of PHP is passed to the D script $target variable so the probes fire just for this invocation of PHP. Note the quoting around the PHP function name passed to DTrace. The parameter must have double quotes included so DTrace knows it is a string. The output is: PHPUnit 3.7.28 by Sebastian Bergmann. ......-> FunSetsTest::testUnionContainsAllElements -> FunSets::singletonSet <- FunSets::singletonSet -> FunSets::singletonSet <- FunSets::singletonSet -> FunSets::union <- FunSets::union -> FunSets::contains -> FunSets::{closure} -> FunSets::contains -> FunSets::{closure} <- FunSets::{closure} <- FunSets::contains <- FunSets::{closure} <- FunSets::contains -> PHPUnit_Framework_Assert::assertTrue -> PHPUnit_Framework_Assert::isTrue <- PHPUnit_Framework_Assert::isTrue -> PHPUnit_Framework_Assert::assertThat -> PHPUnit_Framework_Constraint::count <- PHPUnit_Framework_Constraint::count -> PHPUnit_Framework_Constraint::evaluate -> PHPUnit_Framework_Constraint_IsTrue::matches <- PHPUnit_Framework_Constraint_IsTrue::matches <- PHPUnit_Framework_Constraint::evaluate <- PHPUnit_Framework_Assert::assertThat <- PHPUnit_Framework_Assert::assertTrue -> FunSets::contains -> FunSets::{closure} -> FunSets::contains -> FunSets::{closure} <- FunSets::{closure} <- FunSets::contains -> FunSets::contains -> FunSets::{closure} <- FunSets::{closure} <- FunSets::contains <- FunSets::{closure} <- FunSets::contains -> PHPUnit_Framework_Assert::assertTrue -> PHPUnit_Framework_Assert::isTrue <- PHPUnit_Framework_Assert::isTrue -> PHPUnit_Framework_Assert::assertThat -> PHPUnit_Framework_Constraint::count <- PHPUnit_Framework_Constraint::count -> PHPUnit_Framework_Constraint::evaluate -> PHPUnit_Framework_Constraint_IsTrue::matches <- PHPUnit_Framework_Constraint_IsTrue::matches <- PHPUnit_Framework_Constraint::evaluate <- PHPUnit_Framework_Assert::assertThat <- PHPUnit_Framework_Assert::assertTrue -> FunSets::contains -> FunSets::{closure} -> FunSets::contains -> FunSets::{closure} <- FunSets::{closure} <- FunSets::contains -> FunSets::contains -> FunSets::{closure} <- FunSets::{closure} <- FunSets::contains <- FunSets::{closure} <- FunSets::contains -> PHPUnit_Framework_Assert::assertFalse -> PHPUnit_Framework_Assert::isFalse -> {closure} -> main <- main <- {closure} <- PHPUnit_Framework_Assert::isFalse -> PHPUnit_Framework_Assert::assertThat -> PHPUnit_Framework_Constraint::count <- PHPUnit_Framework_Constraint::count -> PHPUnit_Framework_Constraint::evaluate -> PHPUnit_Framework_Constraint_IsFalse::matches <- PHPUnit_Framework_Constraint_IsFalse::matches <- PHPUnit_Framework_Constraint::evaluate <- PHPUnit_Framework_Assert::assertThat <- PHPUnit_Framework_Assert::assertFalse <- FunSetsTest::testUnionContainsAllElements ... Time: 1.85 seconds, Memory: 3.75Mb OK (9 tests, 23 assertions) The periods correspond to the successful tests before and after (and from) the test I was tracing. You can see the function entry ("->") and return ("<-") points. Cross checking with the testUnionContainsAllElements() source code confirms the two singletonSet() calls, one union() call, two assertTrue() calls and finally an assertFalse() call. These assertions have a contains() call as a parameter, so contains() is called before the PHPUnit assertion functions are run. You can see contains() being called recursively, and how the closures are invoked. If you want to focus on the application logic and suppress the PHPUnit function trace, you could turn off tracing when assertions are being checked by adding D clauses checking the entry and exit of assertFalse() and assertTrue(). But if you want to see all of PHPUnit's code flow, you can modify the functree.d code that sets and unsets self-follow, and instead change it to toggle the variable in request-startup and request-shutdown probes: php$target:::request-startup { self->follow = 1 } php$target:::request-shutdown { self->follow = 0 } Be prepared for a large amount of output!

    Read the article

  • JavaOne pictures and Community Commentary on JCP Awards

    - by heathervc
    We posted some pictures from JCP related events at JavaOne 2012 on the JCP Facebook page today.  The 2012 JCP Program Award winners and some of the nominees responded to the community recognition of their achievements during some of the JCP events last week.     “Our job on the EC is to balance the need of innovation – so we don’t standardize too early, or too late. We try to find that sweet spot that makes innovation and standardization work together, and not against each other.”- Ben Evans, CEO of jClarity and Executive Committee (EC) representative of the London Java Community, 2012 JCP Member/Participant of the Year Winner“SouJava has been evangelizing the Java platform, promoting the Java ecosystem in Brazil, and contributing to JSRs for several years. It’s very gratifying to have our work recognized, on behalf of many developers and Java User Groups around the world. This really is the work of a large group of people, represented by the few that can be here tonight.”- Michael Santos, representative of SouJava, 2012 JCP Member/Participant of the Year Winner "In the last years Credit Suisse has contributed to the development of Java EE specifications through participation in many customer advisory boards, through statements of requirements for extensions to the core Java related products in use, and active participation in JSRs. Winning the JCP Outstanding Spec Lead Award 2012 is very encouraging for our engagement and also demonstrates the level of expertise and commitment to drive the evolution of Java. Victor Grazi is happy and honored to receive this award." - Susanne Cech Previtali, Executive Committee (EC) representative of Credit Suisse, accepting award for 2012 JCP Outstanding Spec Lead Winner "Managing a JSR is difficult. There are so many decisions to be made and so many good and varied opinions, you never really know if you have decided correctly. The key to success is transparency and collaboration. I am truly humbled by receiving this award, there are so many other active JSRs.” Victor added that going forward in the JCP EC, they would like to simplify and open the process of participation – being addressed in the JCP.Next initiative of the JCP EC. "We would also like to encourage the engagement of universities, professors and students – as an important part of the Java community. While innovation is the lifeblood of our community and industry, without strong standards and compatibility requirements, we all end up in a maze of technology where everything is slightly different and doesn’t quite work with everything else." Victo Grazi, Executive Committee (EC) representative of Credit Suisse, 2012 JCP Outstanding Spec Lead Winner“I am very pleased, of course, to accept this award, but the credit really should go to all of those who have participated in the work of the JCP, while pushing for changes in the way it operates.  JCP.Next represents three JSRs. The first two are done, but the final step, JSR 358, is the complicated one, and it will bring in the lawyers. Just to give you an idea of what we’re dealing with, it affects licensing, intellectual property, patents, implementations not based on the Reference Implementation (RI), the role of the RI, compatibility policy, possible changes to the Technical Compatibility Kit (TCK), transparency, where do individuals fit in, open source, and more.”- Patrick Curran, JCP Chair, Spec Lead on JCP.Next JSRs (JSR 348, JSR 355 and JSR 358), 2012 JCP Most Significant JSR Winner“I’m especially glad to see the JCP community recognize JCP.Next for its importance. The governance work it represents is KEY to moving the Java platform forward and the success of the technology.”- John Rizzo, Executive Committee (EC) representative of Aplix Corporation, JSR Expert Group Member “I am deeply honored to be nominated. I had the privilege to receive two awards on behalf of Expert Groups and Spec Leads two years ago. But this time, I am nominated personally, which values my own contribution to the JCP, and of course, participation in JSRs and the EC work. I’m a fan of Agile Principles and Values Working. Being an Agile Coach and Consultant, I use it for some of the biggest EC Member companies and projects. It fuels my ability to help the JCP become more agile, lean and transparent as part of the JCP.Next effort.” - Werner Keil, Individual Executive Committee (EC) Member, a 2012 JCP Member/Participant of the Year Nominee, JSR Expert Group Member“The JCP ever has been some kind of institution for me,” Markus said. “If in technical doubt, I go there, look for the specifications of the implementation I work with at the moment and verify what I had observed. Since the beginning of my Java journey more than 12 years back now, I always had a strong relationship with the JCP. Shaping the future of a technology by joining the JCP – giving feedback and contributing to the road ahead through individual JSRs – that brings you to a whole new level.”Calling himself, “the new kid on the block,” he explained that for years he was afraid to join the JCP and contribute. But in reality, “Every single one of the big names I meet from the different Expert Groups is a nice person. People you can actually work with,” he says. “And nobody blames you for things you don't know. As long as you are committed and bring what is worth the most: passion, experiences and the desire to make a difference.” - Markus Eisele, a 2012 JCP Member of the Year Nominee, JSR Expert Group MemberCongratulations again to all of the nominees and winners of the JCP Program Awards.  Next year, we will add another award for the group of JUG members (not an entire JUG) that makes the best contribution to the Adopt-a-JSR program.  Let us know if you have other suggestions or improvements.

    Read the article

  • Who broke the build?

    - by Martin Hinshelwood
    I recently sent round a list of broken builds at SSW and asked for them to be fixed or deleted if they are not being used. My colleague Peter came back with a couple of questions which I love as it tells me that at least one person reads my email I think first we need to answer a couple of other questions related to builds in general.   Why do we want the build to pass? Any developer can pick up a project and build it Standards can be enforced Constant quality is maintained Problems in code are identified early What could a failed build signify? Developers have not built and tested their code properly before checking in. Something added depends on a local resource that is not under version control or does not exist on the target computer. Developers are not writing tests to cover common problems. There are not enough tests to cover problems. Now we know why, lets answer Peters questions: Where is this list? (can we see it somehow) You can normally only see the builds listed for each project. But, you have a little application called “Build Notifications” on your computer. It is installed when you install Visual Studio 2010. Figure: Staring the build notification application on Windows 7. Once you have it open (it may disappear into your system tray) you should click “Options” and select all the projects you are involved in. This application only lists projects that have builds, so don’t worry if it is not listed. This just means you are about to setup a build, right? I just selected ALL projects that have builds. Figure: All builds are listed here In addition to seeing the list you will also get toast notification of build failure’s. How can we get more info on what broke the build? (who is interesting too, to point the finger but more important is what) The only thing worse than breaking the build, is continuing to develop on a broken build! Figure: I have highlighted the users who either are bad for braking the build, or very bad for not fixing it. To find out what is wrong with a build you need to open the build definition. You can open a web version by double clicking the build in the image above, or you can open it from “Team Explorer”. Just connect to your project and open out the “Builds” tree. Then Open the build by double clicking on it. Figure: Opening a build is easy, but double click it and then open a build run from the list. Figure: Good example, the build and tests have passed Figure: Bad example, there are 133 errors preventing POK from being built on the build server. For identifying failures see: Solution: Getting Silverlight to build on Team Build 2010 RC Solution: Testing Web Services with MSTest on Team Build Finding the problem on a partially succeeded build So, Peter asked about blame, let’s have a look and see: Figure: The build has been broken for so long I have no idea when it was broken, but everyone on this list is to blame (I am there too) The rest of the history is lost in the sands of time, there is no way to tell when the build was originally broken, or by whom, or even if it ever worked in the first place. Build should be protected by the team that uses them and the only way to do that is to have them own them. It is fine for me to go in and setup a build, but the ownership for a build should always reside with the person who broke it last. Conclusion This is an example of a pointless build. Lets be honest, if you have a system like TFS in place and builds are constantly left broken, or not added to projects then your developers don’t yet understand the value. I have found that adding a Gated Check-in helps instil that understanding of value. If you prevent them from checking in without passing that basic quality gate of “your code builds on another computer” then it makes them look more closely at why they can’t check-in. I have had builds fail because one developer had a “d” drive, but the build server did not. That is what they are there to catch.   If you want to know what builds to create and why I wrote a post on “Do you know the minimum builds to create on any branch?”   Technorati Tags: TFS2010,Gated Check-in,Builds,Build Failure,Broken Build

    Read the article

  • Advanced donut caching: using dynamically loaded controls

    - by DigiMortal
    Yesterday I solved one caching problem with local community portal. I enabled output cache on SharePoint Server 2007 to make site faster. Although caching works fine I needed to do some additional work because there are some controls that show different content to different users. In this example I will show you how to use “donut caching” with user controls – powerful way to drive some content around cache. About donut caching Donut caching means that although you are caching your content you have some holes in it so you can still affect the output that goes to user. By example you can cache front page on your site and still show welcome message that contains correct user name. To get better idea about donut caching I suggest you to read ScottGu posting Tip/Trick: Implement "Donut Caching" with the ASP.NET 2.0 Output Cache Substitution Feature. Basically donut caching uses ASP.NET substitution control. In output this control is replaced by string you return from static method bound to substitution control. Again, take a look at ScottGu blog posting I referred above. Problem If you look at Scott’s example it is pretty plain and easy by its output. All it does is it writes out current user name as string. Here are examples of my login area for anonymous and authenticated users:    It is clear that outputting mark-up for these views as string is pretty lame to implement in code at string level. Every little change in design will end up with new version of controls library because some parts of design “live” there. Solution: using user controls I worked out easy solution to my problem. I used cache substitution and user controls together. I have three user controls: LogInControl – this is the proxy control that checks which “real” control to load. AnonymousLogInControl – template and logic for anonymous users login area. AuthenticatedLogInControl – template and logic for authenticated users login area. This is the control we render for each user separately because it contains user name and user profile fill percent. Anonymous control is not very interesting because it is only about keeping mark-up in separate file. Interesting parts are LogInControl and AuthenticatedLogInControl. Creating proxy control The first thing was to create control that has substitution area where “real” control is loaded. This proxy control should also be available to decide which control to load. The definition of control is very primitive. <%@ Control EnableViewState="false" Inherits="MyPortal.Profiles.LogInControl" %> <asp:Substitution runat="server" MethodName="ShowLogInBox" /> But code is a little bit tricky. Based on current user instance we decide which login control to load. Then we create page instance and load our control through it. When control is loaded we will call DataBind() method. In this method we evaluate all fields in loaded control (it was best choice as Load and other events will not be fired). Take a look at the code. public static string ShowLogInBox(HttpContext context) {     var user = SPContext.Current.Web.CurrentUser;     string controlName;       if (user != null)         controlName = "AuthenticatedLogInControl.ascx";     else         controlName = "AnonymousLogInControl.ascx";       var path = "~/_controltemplates/" + controlName;     var output = new StringBuilder(10000);       using(var page = new Page())     using(var ctl = page.LoadControl(path))     using(var writer = new StringWriter(output))     using(var htmlWriter = new HtmlTextWriter(writer))     {         ctl.DataBind();         ctl.RenderControl(htmlWriter);     }     return output.ToString(); } When control is bound to data we ask to render it its contents to StringBuilder. Now we have the output of control as string and we can return it from our method. Of course, notice how correct I am with resources disposing. :) The method that returns contents for substitution control is static method that has no connection with control instance because hen page is read from cache there are no instances of controls available. Conclusion As you saw it was not very hard to use donut caching with user controls. Instead of writing mark-up of controls to static method that is bound to substitution control we can still use our user controls.

    Read the article

  • A New Threat To Web Applications: Connection String Parameter Pollution (CSPP)

    - by eric.maurice
    Hi, this is Shaomin Wang. I am a security analyst in Oracle's Security Alerts Group. My primary responsibility is to evaluate the security vulnerabilities reported externally by security researchers on Oracle Fusion Middleware and to ensure timely resolution through the Critical Patch Update. Today, I am going to talk about a serious type of attack: Connection String Parameter Pollution (CSPP). Earlier this year, at the Black Hat DC 2010 Conference, two Spanish security researchers, Jose Palazon and Chema Alonso, unveiled a new class of security vulnerabilities, which target insecure dynamic connections between web applications and databases. The attack called Connection String Parameter Pollution (CSPP) exploits specifically the semicolon delimited database connection strings that are constructed dynamically based on the user inputs from web applications. CSPP, if carried out successfully, can be used to steal user identities and hijack web credentials. CSPP is a high risk attack because of the relative ease with which it can be carried out (low access complexity) and the potential results it can have (high impact). In today's blog, we are going to first look at what connection strings are and then review the different ways connection string injections can be leveraged by malicious hackers. We will then discuss how CSPP differs from traditional connection string injection, and the measures organizations can take to prevent this kind of attacks. In web applications, a connection string is a set of values that specifies information to connect to backend data repositories, in most cases, databases. The connection string is passed to a provider or driver to initiate a connection. Vendors or manufacturers write their own providers for different databases. Since there are many different providers and each provider has multiple ways to make a connection, there are many different ways to write a connection string. Here are some examples of connection strings from Oracle Data Provider for .Net/ODP.Net: Oracle Data Provider for .Net / ODP.Net; Manufacturer: Oracle; Type: .NET Framework Class Library: - Using TNS Data Source = orcl; User ID = myUsername; Password = myPassword; - Using integrated security Data Source = orcl; Integrated Security = SSPI; - Using the Easy Connect Naming Method Data Source = username/password@//myserver:1521/my.server.com - Specifying Pooling parameters Data Source=myOracleDB; User Id=myUsername; Password=myPassword; Min Pool Size=10; Connection Lifetime=120; Connection Timeout=60; Incr Pool Size=5; Decr Pool Size=2; There are many variations of the connection strings, but the majority of connection strings are key value pairs delimited by semicolons. Attacks on connection strings are not new (see for example, this SANS White Paper on Securing SQL Connection String). Connection strings are vulnerable to injection attacks when dynamic string concatenation is used to build connection strings based on user input. When the user input is not validated or filtered, and malicious text or characters are not properly escaped, an attacker can potentially access sensitive data or resources. For a number of years now, vendors, including Oracle, have created connection string builder class tools to help developers generate valid connection strings and potentially prevent this kind of vulnerability. Unfortunately, not all application developers use these utilities because they are not aware of the danger posed by this kind of attacks. So how are Connection String parameter Pollution (CSPP) attacks different from traditional Connection String Injection attacks? First, let's look at what parameter pollution attacks are. Parameter pollution is a technique, which typically involves appending repeating parameters to the request strings to attack the receiving end. Much of the public attention around parameter pollution was initiated as a result of a presentation on HTTP Parameter Pollution attacks by Stefano Di Paola and Luca Carettoni delivered at the 2009 Appsec OWASP Conference in Poland. In HTTP Parameter Pollution attacks, an attacker submits additional parameters in HTTP GET/POST to a web application, and if these parameters have the same name as an existing parameter, the web application may react in different ways depends on how the web application and web server deal with multiple parameters with the same name. When applied to connections strings, the rule for the majority of database providers is the "last one wins" algorithm. If a KEYWORD=VALUE pair occurs more than once in the connection string, the value associated with the LAST occurrence is used. This opens the door to some serious attacks. By way of example, in a web application, a user enters username and password; a subsequent connection string is generated to connect to the back end database. Data Source = myDataSource; Initial Catalog = db; Integrated Security = no; User ID = myUsername; Password = XXX; In the password field, if the attacker enters "xxx; Integrated Security = true", the connection string becomes, Data Source = myDataSource; Initial Catalog = db; Integrated Security = no; User ID = myUsername; Password = XXX; Intergrated Security = true; Under the "last one wins" principle, the web application will then try to connect to the database using the operating system account under which the application is running to bypass normal authentication. CSPP poses serious risks for unprepared organizations. It can be particularly dangerous if an Enterprise Systems Management web front-end is compromised, because attackers can then gain access to control panels to configure databases, systems accounts, etc. Fortunately, organizations can take steps to prevent this kind of attacks. CSPP falls into the Injection category of attacks like Cross Site Scripting or SQL Injection, which are made possible when inputs from users are not properly escaped or sanitized. Escaping is a technique used to ensure that characters (mostly from user inputs) are treated as data, not as characters, that is relevant to the interpreter's parser. Software developers need to become aware of the danger of these attacks and learn about the defenses mechanism they need to introduce in their code. As well, software vendors need to provide templates or classes to facilitate coding and eliminate developers' guesswork for protecting against such vulnerabilities. Oracle has introduced the OracleConnectionStringBuilder class in Oracle Data Provider for .NET. Using this class, developers can employ a configuration file to provide the connection string and/or dynamically set the values through key/value pairs. It makes creating connection strings less error-prone and easier to manager, and ultimately using the OracleConnectionStringBuilder class provides better security against injection into connection strings. For More Information: - The OracleConnectionStringBuilder is located at http://download.oracle.com/docs/cd/B28359_01/win.111/b28375/OracleConnectionStringBuilderClass.htm - Oracle has developed a publicly available course on preventing SQL Injections. The Server Technologies Curriculum course "Defending Against SQL Injection Attacks!" is located at http://st-curriculum.oracle.com/tutorial/SQLInjection/index.htm - The OWASP web site also provides a number of useful resources. It is located at http://www.owasp.org/index.php/Main_Page

    Read the article

  • Responsible BI for Excel, Even for Older Versions

    - by andrewbrust
    On Wednesday, I will have the honor of co-presenting, for both The Data Warehouse Institute (TDWI) and the New York Technology Council. on the subject of Excel and BI. My co-presenter will be none other than Bill Baker, who was a Microsoft Distinguished Engineer and, essentially, the father of BI at that company.  Details on the events are here and here. We'll be talking about PowerPivot, of course, but that's not all. Probably even more important than any one product, will be our discussion of whether the usual characterization of Excel as the nemesis of IT, the guilty pleasure of business users and the antithesis of formal BI is really valid and/or hopelessly intractable. Without giving away our punchline, I'll tell you that we are much more optimistic than that. There are huge upsides to Excel and while there are real dangers to using it in the BI space, there are standards and practices you can employ to ensure Excel is used responsibly. And when those practices are followed, Excel becomes quite powerful indeed. One of the keys to this is using Excel as a data consumer rather than data storage mechanism. Caching data in Excel is OK, but only if that data is (a) not modified and (b) configured for automated periodic refresh. PowerPivot meets both criteria -- it stores a read-only copy of your data in the form of a model, and once workbook containing a PowerPivot model is published to SharePoint, it can be configured for scheduled data refresh, on the server, requiring no user intervention whatsoever. Data refresh is a bit like hard drive backup: it will only happen reliably if it's automated, and super-easy to configure. PowerPivot hits a real home run here (as does Windows Home Server for PC backup, but I digress). The thing about PowerPivot is that it's an add-in for Excel 2010. What if you're not planning to go to that new version for quite a while? What if you’ve just deployed Office 2007 in your organization? What if you're still on Office 2003, or an even earlier version? What can you do immediately to share data responsibly and easily? As it turns out, there's a feature in Excel that's been around for quite a while, that can help: Web Queries.  The Web Query feature was introduced, ostensibly, to allow Excel to pull data in from Internet Web pages…for example, data in a stock quote history table will come in nicely, as will any data in a Web page that is displayed in an HTML table.  To use the feature In Excel 2007 or 2010, click the Data Tab or the ribbon and click the “From Web” button towards the left; in older versions use the corresponding option in  the menu or  toolbars.  Next, paste a URL into the resulting dialog box and tap Enter or click the Go button.  A preview of the Web page will come up, and the dialog will allow you to select the specific table within the page whose data you’d like to import.  Here’s an example: Now just click the table, click the Import button, and the Import Data dialog appears.  You can simply click OK to bring in your data or you can first click the Properties… button and configure the data import to be refreshed at an interval in minutes that you select.  Now your data’s in the spreadsheet and ready to worked with: Your data may be vulnerable to modification, but if you’ve set up the data refresh, any accidental or malicious changes will be corrected in time anyway. The thing about this feature is that it’s most useful not for public Web pages, but for pages behind the firewall.  In effect, the Web Query feature provides an incredibly easy way to consume data in Excel that’s “published” from an application.  Users just need a URL.  They don’t need to know server and database names and since the data is read-only, providing credentials may be unnecessary, or can be handled using integrated security.  If that’s not good enough, the Web Query can be saved to a special .iqy file, which can be edited to provide POST parameter data. The only requirement is that the data must be provided in an HTML table, with the first row providing the column names.  From an ASP.NET project, it couldn’t be easier: a simple bound GridView control is totally compatible.  Use a data source control with it, and you don’t even have to write any code.  Users can link to pages that are part of an application’s UI, or developers can create pages that are specially designed for the purpose of providing an interface to the Web Query import feature.  And none of this is Microsoft- or .NET-specific.  You can create pages in any language you want (PHP comes to mind) that output the result set of a query in HTML table format, and then consume that data in a Web Query.  Then build PivotTables and charts on the data, and in Excel 2007 or 2010 you can use conditional formatting to create scorecards and dashboards. This strategy allows you to create pages that function quite similarly to the OData XML feeds rendered when .NET developers create an “Astoria” WCF Data Service.  And while it’s cool that PowerPivot and Excel 2010 can import such OData feeds, it’s good to know that older versions of Excel can function in a similar fashion, and can consume data produced by virtually any Web development platform. As a final matter, instead of just telling you that “older versions” of Excel support this feature, I’ll be more specific.  To discover what the first version of Excel was to support Web queries, go to http://bit.ly/OldSchoolXL.

    Read the article

  • Creating an SMF service for mercurial web server

    - by Chris W Beal
    I'm working on a project at the moment, which has a number of contributers. We're managing the project gate (which is stand alone) with mercurial. We want to have an easy way of seeing the changelog, so we can show management what is going on.  Luckily mercurial provides a basic web server which allows you to see the changes, and drill in to change sets. This can be run as a daemon, but as it was running on our build server, every time it was rebooted, someone needed to remember to start the process again. This is of course a classic usage of SMF. Now I'm not an experienced person at writing SMF services, so it took me 1/2 an hour or so to figure it out the first time. But going forward I should know what I'm doing a bit better. I did reference this doc extensively. Taking a step back, the command to start the mercurial web server is $ hg serve -p <port number> -d So we somehow need to get SMF to run that command for us. In the simplest form, SMF services are really made up of two components. The manifest Usually lives in /var/svc/manifest somewhere Can be imported from any location The method Usually live in /lib/svc/method I simply put the script straight in that directory. Not very repeatable, but it worked Can take an argument of start, stop, or refresh Lets start with the manifest. This looks pretty complex, but all it's doing is describing the service name, the dependencies, the start and stop methods, and some properties. The properties can be by instance, that is to say I could have multiple hg serve processes handling different mercurial projects, on different ports simultaneously Here is the manifest I wrote. I stole extensively from the examples in the Documentation. So my manifest looks like this $ cat hg-serve.xml <?xml version="1.0"?> <!DOCTYPE service_bundle SYSTEM "/usr/share/lib/xml/dtd/service_bundle.dtd.1"> <service_bundle type='manifest' name='hg-serve'> <service name='application/network/hg-serve' type='service' version='1'> <dependency name='network' grouping='require_all' restart_on='none' type='service'> <service_fmri value='svc:/milestone/network:default' /> </dependency> <exec_method type='method' name='start' exec='/lib/svc/method/hg-serve %m' timeout_seconds='2' /> <exec_method type='method' name='stop' exec=':kill' timeout_seconds='2'> </exec_method> <instance name='project-gate' enabled='true'> <method_context> <method_credential user='root' group='root' /> </method_context> <property_group name='hg-serve' type='application'> <propval name='path' type='astring' value='/src/project-gate'/> <propval name='port' type='astring' value='9998' /> </property_group> </instance> <stability value='Evolving' /> <template> <common_name> <loctext xml:lang='C'>hg-serve</loctext> </common_name> <documentation> <manpage title='hg' section='1' /> </documentation> </template> </service> </service_bundle> So the only things I had to decide on in this are the service name "application/network/hg-serve" the start and stop methods (more of which later) and the properties. This is the information I need to pass to the start method script. In my case the port I want to start the web server on "9998", and the path to the source gate "/src/project-gate". These can be read in to the start method. So now lets look at the method scripts $ cat /lib/svc/method/hg-serve #!/sbin/sh # # # Copyright (c) 2012, Oracle and/or its affiliates. All rights reserved. # # Standard prolog # . /lib/svc/share/smf_include.sh if [ -z $SMF_FMRI ]; then echo "SMF framework variables are not initialized." exit $SMF_EXIT_ERR fi # # Build the command line flags # # Get the port and directory from the SMF properties port=`svcprop -c -p hg-serve/port $SMF_FMRI` dir=`svcprop -c -p hg-serve/path $SMF_FMRI` echo "$1" case "$1" in 'start') cd $dir /usr/bin/hg serve -d -p $port ;; *) echo "Usage: $0 {start|refresh|stop}" exit 1 ;; esac exit $SMF_EXIT_OK This is all pretty self explanatory, we read the port and directory using svcprop, and use those simply to run a command in the start case. We don't need to implement a stop case, as the manifest says to use "exec=':kill'for the stop method. Now all we need to do is import the manifest and start the service, but first verify the manifest # svccfg verify /path/to/hg-serve.xml If that doesn't give an error try importing it # svccfg import /path/to/hg-serve.xml If like me you originally put the hg-serve.xml file in /var/svc/manifest somewhere you'll get an error and told to restart the import service svccfg: Restarting svc:/system/manifest-import The manifest being imported is from a standard location and should be imported with the command : svcadm restart svc:/system/manifest-import # svcadm restart svc:/system/manifest-import and you're nearly done. You can look at the service using svcs -l # svcs -l hg-serve fmri svc:/application/network/hg-serve:project-gate name hg-serve enabled false state disabled next_state none state_time Thu May 31 16:11:47 2012 logfile /var/svc/log/application-network-hg-serve:project-gate.log restarter svc:/system/svc/restarter:default contract_id 15749 manifest /var/svc/manifest/network/hg/hg-serve.xml dependency require_all/none svc:/milestone/network:default (online) And look at the interesting properties # svcprop hg-serve hg-serve/path astring /src/project-gate hg-serve/port astring 9998 ...stuff deleted.... Then simply enable the service and if every things gone right, you can point your browser at http://server:9998 and get a nice graphical log of project activity. # svcadm enable hg-serve # svcs -l hg-serve fmri svc:/application/network/hg-serve:project-gate name hg-serve enabled true state online next_state none state_time Thu May 31 16:18:11 2012 logfile /var/svc/log/application-network-hg-serve:project-gate.log restarter svc:/system/svc/restarter:default contract_id 15858 manifest /var/svc/manifest/network/hg/hg-serve.xml dependency require_all/none svc:/milestone/network:default (online) None of this is rocket science, but a bit fiddly. Hence I thought I'd blog it. It might just be you see this in google and it clicks with you more than one of the many other blogs or how tos about it. Plus I can always refer back to it myself in 3 weeks, when I want to add another project to the server, and I've forgotten how to do it.

    Read the article

  • Tuning Red Gate: #4 of Some

    - by Grant Fritchey
    First time connecting to these servers directly (keys to the kingdom, bwa-ha-ha-ha. oh, excuse me), so I'm going to take a look at the server properties, just to see if there are any issues there. Max memory is set, cool, first possible silly mistake clear. In fact, these look to be nicely set up. Oh, I'd like to see the ANSI Standards set by default, but it's not a big deal. The default location for database data is the F:\ drive, where I saw all the activity last time. Cool, the people maintaining the servers in our company listen, parallelism threshold is set to 35 and optimize for ad hoc is enabled. No shocks, no surprises. The basic setup is appropriate. On to the problem database. Nothing wrong in the properties. The database is in SIMPLE recovery, but I think it's a reporting system, so no worries there. Again, I'd prefer to see the ANSI settings for connections, but that's the worst thing I can see. Time to look at the queries, tables, indexes and statistics because all the information I've collected over the last several days suggests that we're not looking at a systemic problem (except possibly not enough memory), but at the traditional tuning issues. I just want to note that, I started looking at the system, not the queries. So should you when tuning your environment. I know, from the data collected through SQL Monitor, what my top poor performing queries are, and the most frequently called, etc. I'm starting with the most frequently called. I'm going to get the execution plan for this thing out of the cache (although, with the cache dumping constantly, I might not get it). And it's not there. Called 1.3 million times over the last 3 days, but it's not in cache. Wow. OK. I'll see what's in cache for this database: SELECT  deqs.creation_time,         deqs.execution_count,         deqs.max_logical_reads,         deqs.max_elapsed_time,         deqs.total_logical_reads,         deqs.total_elapsed_time,         deqp.query_plan,         SUBSTRING(dest.text, (deqs.statement_start_offset / 2) + 1,                   (deqs.statement_end_offset - deqs.statement_start_offset) / 2                   + 1) AS QueryStatement FROM    sys.dm_exec_query_stats AS deqs         CROSS APPLY sys.dm_exec_sql_text(deqs.sql_handle) AS dest         CROSS APPLY sys.dm_exec_query_plan(deqs.plan_handle) AS deqp WHERE   dest.dbid = DB_ID('Warehouse') AND deqs.statement_end_offset > 0 AND deqs.statement_start_offset > 0 ORDER BY deqs.max_logical_reads DESC ; And looking at the most expensive operation, we have our first bad boy: Multiple table scans against very large sets of data and a sort operation. a sort operation? It's an insert. Oh, I see, the table is a heap, so it's doing an insert, then sorting the data and then inserting into the primary key. First question, why isn't this a clustered index? Let's look at some more of the queries. The next one is deceiving. Here's the query plan: You're thinking to yourself, what's the big deal? Well, what if I told you that this thing had 8036318 reads? I know, you're looking at skinny little pipes. Know why? Table variable. Estimated number of rows = 1. Actual number of rows. well, I'm betting several more than one considering it's read 8 MILLION pages off the disk in a single execution. We have a serious and real tuning candidate. Oh, and I missed this, it's loading the table variable from a user defined function. Let me check, let me check. YES! A multi-statement table valued user defined function. And another tuning opportunity. This one's a beauty, seriously. Did I also mention that they're doing a hash against all the columns in the physical table. I'm sure that won't lead to scans of a 500,000 row table, no, not at all. OK. I lied. Of course it is. At least it's on the top part of the Loop which means the scan is only executed once. I just did a cursory check on the next several poor performers. all calling the UDF. I think I found a big tuning opportunity. At this point, I'm typing up internal emails for the company. Someone just had their baby called ugly. In addition to a series of suggested changes that we need to implement, I'm also apologizing for being such an unkind monster as to question whether that third eye & those flippers belong on such an otherwise lovely child.

    Read the article

  • Establishing WebLogic Server HTTPS Trust of IIS Using a Microsoft Local Certificate Authority

    - by user647124
    Everyone agrees that self-signed and demo certificates for SSL and HTTPS should never be used in production and preferred not to be used elsewhere. Most self-signed and demo certificates are provided by vendors with the intention that they are used only to integrate within the same environment. In a vendor’s perfect world all application servers in a given enterprise are from the same vendor, which makes this lack of interoperability in a non-production environment an advantage. For us working in the real world, where not only do we not use a single vendor everywhere but have to make do with self-signed certificates for all but production, testing HTTPS between an IIS ASP.NET service provider and a WebLogic J2EE consumer application can be very frustrating to set up. It was for me, especially having found many blogs and discussion threads where various solutions were described but did not quite work and were all mostly similar but just a little bit different. To save both you and my future (who always seems to forget the hardest-won lessons) all of the pain and suffering, I am recording the steps that finally worked here for reference and sanity. How You Know You Need This The first cold clutches of dread that tells you it is going to be a long day is when you attempt to a WSDL published by IIS in WebLogic over HTTPS and you see the following: <Jul 30, 2012 2:51:31 PM EDT> <Warning> <Security> <BEA-090477> <Certificate chain received from myserver.mydomain.com - 10.555.55.123 was not trusted causing SSL handshake failure.> weblogic.wsee.wsdl.WsdlException: Failed to read wsdl file from url due to -- javax.net.ssl.SSLKeyException: [Security:090477]Certificate chain received from myserver02.mydomain.com - 10.555.55.123 was not trusted causing SSL handshake failure. The above is what started a three day sojourn into searching for a solution. Even people who had solved it before would tell me how they did, and then shrug when I demonstrated that the steps did not end in the success they claimed I would experience. Rather than torture you with the details of everything I did that did not work, here is what finally did work. Export the Certificates from IE First, take the offending WSDL URL and paste it into IE (if you have an internal Microsoft CA, you have IE, even if you don’t use it in favor of some other browser). To state the semi-obvious, if you received the error above there is a certificate configured for the IIS host of the service and the SSL port has been configured properly. Otherwise there would be a different error, usually about the site not found or connection failed. Once the WSDL loads, to the right of the address bar there will be a lock icon. Click the lock and then click View Certificates in the resulting dialog (if you do not have a lock icon but do have a Certificate Error message, see http://support.microsoft.com/kb/931850 for steps to install the certificate then you can continue from the point of finding the lock icon). Figure 1: View Certificates in IE Next, select the Details tab in the resulting dialog Figure 2: Use Certificate Details to Export Certificate Click Copy to File, then Next, then select the Base-64 encoded option for the format Figure 3: Select the Base-64 encoded option for the format For the sake of simplicity, I choose to save this to the root of the WebLogic domain. It will work from anywhere, but later you will need to type in the full path rather than just the certificate name if you save it elsewhere. Figure 4: Browse to Save Location Figure 5: Save the Certificate to the Domain Root for Convenience This is the point where I ran into some confusion. Some articles mentioned exporting the entire chain of certificates. This supposedly works for some types of certificates, or if you have a few other tools and the time to learn them. For the SSL experts out there, they already have these tools, know how to use them well, and should not be wasting their time reading this article meant for folks who just want to get things wired up and back to unit testing and development. For the rest of us, the easiest way to make sure things will work is to just export all the links in the chain individually and let WebLogic Server worry about re-assembling them into a chain (which it does quite nicely). While perhaps not the most elegant solution, the multi-step process is easy to repeat and uses only tools that are immediately available and require no learning curve. So… Next, go to Tools then Internet Options then the Content tab and click Certificates. Go to the Trust Root Certificate Authorities tab and find the certificate root for your Microsoft CA cert (look for the Issuer of the certificate you exported earlier). Figure 6: Trusted Root Certification Authorities Tab Export this one the same way as before, with a different name Figure 7: Use a Unique Name for Each Certificate Repeat this once more for the Intermediate Certificate tab. Import the Certificates to the WebLogic Domain Now, open an command prompt, navigate to [WEBLOGIC_DOMAIN_ROOT]\bin and execute setDomainEnv. You should then be in the root of the domain. If not, CD to the domain root. Assuming you saved the certificate in the domain root, execute the following: keytool -importcert -alias [ALIAS-1] -trustcacerts -file [FULL PATH TO .CER 1] -keystore truststore.jks -storepass [PASSWORD] An example with the variables filled in is: keytool -importcert -alias IIS-1 -trustcacerts -file microsftcert.cer -keystore truststore.jks -storepass password After several lines out output you will be prompted with: Trust this certificate? [no]: The correct answer is ‘yes’ (minus the quotes, of course). You’ll you know you were successful if the response is: Certificate was added to keystore If not, check your typing, as that is generally the source of an error at this point. Repeat this for all three of the certificates you exported, changing the [ALIAS-1] and [FULL PATH TO .CER 1] value each time. For example: keytool -importcert -alias IIS-1 -trustcacerts -file microsftcert.cer -keystore truststore.jks -storepass password keytool -importcert -alias IIS-2 -trustcacerts -file microsftcertRoot.cer -keystore truststore.jks -storepass password keytool -importcert -alias IIS-3 -trustcacerts -file microsftcertIntermediate.cer -keystore truststore.jks -storepass password In the above we created a new JKS key store. You can re-use an existing one by changing the name of the JKS file to one you already have and change the password to the one that matches that JKS file. For the DemoTrust.jks  that is included with WebLogic the password is DemoTrustKeyStorePassPhrase. An example here would be: keytool -importcert -alias IIS-1 -trustcacerts -file microsoft.cer -keystore DemoTrust.jks -storepass DemoTrustKeyStorePassPhrase keytool -importcert -alias IIS-2 -trustcacerts -file microsoftRoot.cer -keystore DemoTrust.jks -storepass DemoTrustKeyStorePassPhrase keytool -importcert -alias IIS-2 -trustcacerts -file microsoftInter.cer -keystore DemoTrust.jks -storepass DemoTrustKeyStorePassPhrase Whichever keystore you use, you can check your work with: keytool -list -keystore truststore.jks -storepass password Where “truststore.jks” and “password” can be replaced appropriately if necessary. The output will look something like this: Figure 8: Output from keytool -list -keystore Update the WebLogic Keystore Configuration If you used an existing keystore rather than creating a new one, you can restart your WebLogic Server and skip the rest of this section. For those of us who created a new one because that is the instructions we found online… Next, we need to tell WebLogic to use the JKS file (truststore.jks) we just created. Log in to the WebLogic Server Administration Console and navigate to Servers > AdminServer > Configuration > Keystores. Scroll down to “Custom Trust Keystore:” and change the value to “truststore.jks” and the value of “Custom Trust Keystore Passphrase:” and “Confirm Custom Trust Keystore Passphrase:” to the password you used when earlier, then save your changes. You will get a nice message similar to the following: Figure 9: To Be Safe, Restart Anyways The “No restarts are necessary” is somewhat of an exaggeration. If you want to be able to use the keystore you may need restart the server(s). To save myself aggravation, I always do. Your mileage may vary. Conclusion That should get you there. If there are some erroneous steps included for your situation in particular, I will offer up a semi-apology as the process described above does not take long at all and if there is one step that could be dropped from it, is still much faster than trying to figure this out from other sources.

    Read the article

  • Running Solaris 11 as a control domain on a T2000

    - by jsavit
    There is increased adoption of Oracle Solaris 11, and many customers are deploying it on systems that previously ran Solaris 10. That includes older T1-processor based systems like T1000 and T2000. Even though they are old (from 2005) and don't have the performance of current SPARC servers, they are still functional, stable servers that customers continue to operate. One reason to install Solaris 11 on them is that older machines are attractive for testing OS upgrades before updating current, production systems. Normally this does not present a challenge, because Solaris 11 runs on any T-series or M-series SPARC server. One scenario adds a complication: running Solaris 11 in a control domain on a T1000 or T2000 hosting logical domains. Solaris 11 pre-installed Oracle VM Server for SPARC incompatible with T1 Unlike Solaris 10, Solaris 11 comes with Oracle VM Server for SPARC preinstalled. The ldomsmanager package contains the logical domains manager for Oracle VM Server for SPARC 2.2, which requires a SPARC T2, T2+, T3, or T4 server. It does not work with T1-processor systems, which are only supported by LDoms Manager 1.2 and earlier. The following screenshot shows what happens (bold font) if you try to use Oracle VM Server for SPARC 2.x commands in a Solaris 11 control domain. The commands were issued in a control domain on a T2000 that previously ran Solaris 10. We also display the version of the logical domains manager installed in Solaris 11: root@t2000 psrinfo -vp The physical processor has 4 virtual processors (0-3) UltraSPARC-T1 (chipid 0, clock 1200 MHz) # prtconf|grep T SUNW,Sun-Fire-T200 # ldm -V Failed to connect to logical domain manager: Connection refused # pkg info ldomsmanager Name: system/ldoms/ldomsmanager Summary: Logical Domains Manager Description: LDoms Manager - Virtualization for SPARC T-Series Category: System/Virtualization State: Installed Publisher: solaris Version: 2.2.0.0 Build Release: 5.11 Branch: 0.175.0.8.0.3.0 Packaging Date: May 25, 2012 10:20:48 PM Size: 2.86 MB FMRI: pkg://solaris/system/ldoms/[email protected],5.11-0.175.0.8.0.3.0:20120525T222048Z The 2.2 version of the logical domains manager will have to be removed, and 1.2 installed, in order to use this as a control domain. Preparing to change - create a new boot environment Before doing anything else, lets create a new boot environment: # beadm list BE Active Mountpoint Space Policy Created -- ------ ---------- ----- ------ ------- solaris NR / 2.14G static 2012-09-25 10:32 # beadm create solaris-1 # beadm activate solaris-1 # beadm list BE Active Mountpoint Space Policy Created -- ------ ---------- ----- ------ ------- solaris N / 4.82M static 2012-09-25 10:32 solaris-1 R - 2.14G static 2012-09-29 11:40 # init 0 Normally an init 6 to reboot would have been sufficient, but in the next step I reset the system anyway in order to put the system in factory default mode for a "clean" domain configuration. Preparing to change - reset to factory default There was a leftover domain configuration on the T2000, so I reset it to the factory install state. Since the ldm command is't working yet, it can't be done from the control domain, so I did it by logging onto to the service processor: $ ssh -X admin@t2000-sc Copyright (c) 2010, Oracle and/or its affiliates. All rights reserved. Oracle Advanced Lights Out Manager CMT v1.7.9 Please login: admin Please Enter password: ******** sc> showhost Sun-Fire-T2000 System Firmware 6.7.10 2010/07/14 16:35 Host flash versions: OBP 4.30.4.b 2010/07/09 13:48 Hypervisor 1.7.3.c 2010/07/09 15:14 POST 4.30.4.b 2010/07/09 14:24 sc> bootmode config="factory-default" sc> poweroff Are you sure you want to power off the system [y/n]? y SC Alert: SC Request to Power Off Host. SC Alert: Host system has shut down. sc> poweron SC Alert: Host System has Reset At this point I rebooted into the new Solaris 11 boot environment, and Solaris commands showed it was running on the factory default configuration of a single domain owning all 32 CPUs and 32GB of RAM (that's what it looked like in 2005.) # psrinfo -vp The physical processor has 8 cores and 32 virtual processors (0-31) The core has 4 virtual processors (0-3) The core has 4 virtual processors (4-7) The core has 4 virtual processors (8-11) The core has 4 virtual processors (12-15) The core has 4 virtual processors (16-19) The core has 4 virtual processors (20-23) The core has 4 virtual processors (24-27) The core has 4 virtual processors (28-31) UltraSPARC-T1 (chipid 0, clock 1200 MHz) # prtconf|grep Mem Memory size: 32640 Megabytes Note that the older processor has 4 virtual CPUs per core, while current processors have 8 per core. Remove ldomsmanager 2.2 and install the 1.2 version The Solaris 11 pkg command is now used to remove the 2.2 version that shipped with Solaris 11: # pkg uninstall ldomsmanager Packages to remove: 1 Create boot environment: No Create backup boot environment: No Services to change: 2 PHASE ACTIONS Removal Phase 130/130 PHASE ITEMS Package State Update Phase 1/1 Package Cache Update Phase 1/1 Image State Update Phase 2/2 Finally, LDoms 1.2 installed via its install script, the same way it was done years ago: # unzip LDoms-1_2-Integration-10.zip # cd LDoms-1_2-Integration-10/Install/ # ./install-ldm Welcome to the LDoms installer. You are about to install the Logical Domains Manager package that will enable you to create, destroy and control other domains on your system. Given the capabilities of the LDoms domain manager, you can now change the security configuration of this Solaris instance using the Solaris Security Toolkit. ... ... normal install messages omitted ... The Solaris Security Toolkit applies to Solaris 10, and cannot be used in Solaris 11 (in which several things hardened by the Toolkit are already hardened by default), so answer b in the choice below: You are about to install the Logical Domains Manager package that will enable you to create, destroy and control other domains on your system. Given the capabilities of the LDoms domain manager, you can now change the security configuration of this Solaris instance using the Solaris Security Toolkit. Select a security profile from this list: a) Hardened Solaris configuration for LDoms (recommended) b) Standard Solaris configuration c) Your custom-defined Solaris security configuration profile Enter a, b, or c [a]: b ... other install messages omitted for brevity... After install I ensure that the necessary services are enabled, and verify the version of the installed LDoms Manager: # svcs ldmd STATE STIME FMRI online 22:00:36 svc:/ldoms/ldmd:default # svcs vntsd STATE STIME FMRI disabled Aug_19 svc:/ldoms/vntsd:default # ldm -V Logical Domain Manager (v 1.2-debug) Hypervisor control protocol v 1.3 Using Hypervisor MD v 1.1 System PROM: Hypervisor v. 1.7.3. @(#)Hypervisor 1.7.3.c 2010/07/09 15:14\015 OpenBoot v. 4.30.4. @(#)OBP 4.30.4.b 2010/07/09 13:48 Set up control domain and domain services At this point we have a functioning LDoms 1.2 environment that can be configured in the usual fashion. One difference is that LDoms 1.2 behavior had 'delayed configuration mode (as expected) during initial configuration before rebooting the control domain. Another minor difference with a Solaris 11 control domain is that you define virtual switches using the 'vanity name' of the network interface, rather than the hardware driver name as in Solaris 10. # ldm list ------------------------------------------------------------------------------ Notice: the LDom Manager is running in configuration mode. Configuration and resource information is displayed for the configuration under construction; not the current active configuration. The configuration being constructed will only take effect after it is downloaded to the system controller and the host is reset. ------------------------------------------------------------------------------ NAME STATE FLAGS CONS VCPU MEMORY UTIL UPTIME primary active -n-c-- SP 32 32640M 3.2% 4d 2h 50m # ldm add-vdiskserver primary-vds0 primary # ldm add-vconscon port-range=5000-5100 primary-vcc0 primary # ldm add-vswitch net-dev=net0 primary-vsw0 primary # ldm set-mau 2 primary # ldm set-vcpu 8 primary # ldm set-memory 4g primary # ldm add-config initial # ldm list-spconfig factory-default initial [current] That's it, really. After reboot, we are ready to install guest domains. Summary - new wine in old bottles This example shows that (new) Solaris 11 can be installed on (old) T2000 servers and used as a control domain. The main activity is to remove the preinstalled Oracle VM Server for 2.2 and install Logical Domains 1.2 - the last version of LDoms to support T1-processor systems. I tested Solaris 10 and Solaris 11 guest domains running on this server and they worked without any surprises. This is a viable way to get further into Solaris 11 adoption, even on older T-series equipment.

    Read the article

  • Five Ways Enterprise 2.0 Can Transform Your Business - Q&A from the Webcast

    - by [email protected]
    A few weeks ago, Vince Casarez and I presented with KMWorld on the Five Ways Enterprise 2.0 Can Transform Your Business. It was an enjoyable, interactive webcast in which Vince and I discussed the ways Enterprise 2.0 can transform your business and more importantly, highlighted key customer examples of how to do so. If you missed the webcast, you can catch a replay here. We had a lot of audience participation in some of the polls we conducted and in the Q&A session. We weren't able to address all of the questions during the broadcast, so we attempted to answer them here: Q: Which area within your firm focuses on Web 2.0? Meaning, do you find new departments developing just to manage the web 2.0 (Twitter, Facebook, etc.) user experience or are you structuring current departments? A: There are three distinct efforts within Oracle. The first is around delivery of these Web 2.0 services for enterprise deployments. This is the focus of the WebCenter team. The second effort is injecting these Web 2.0 services into use cases that drive the different enterprise applications. This effort is focused on how to manage these external services and bring them into a cohesive flow for marketing programs, customer care, and purchasing. The third effort is how we consume these services internally to enhance Oracle's business delivery. It leverages the technologies and use cases of the first two but also pushes the envelope with regards to future directions of these other two areas. Q: In a business, Web 2.0 is mostly like action logs. How can we leverage the official process practice versus the logs of a recent action? Example: a system configuration modified last night on a call out versus the official practice that everybody would use in the morning.A: The key thing to remember is that most Web 2.0 actions / activity streams today are based on collaboration and communication type actions. At least with public social sites like Facebook and Twitter. What we're delivering as part of the WebCenter Suite are not just these types of activities but also enterprise application activities. These enterprise application activities come from different application modules: purchasing, HR, order entry, sales opportunity, etc. The actions within these systems are normally tied to a business object or process: purchase order/customer, employee or department, customer and supplier, customer and product, respectively. Therefore, the activities or "logs" as you name them are able to be "typed" so that as a viewer, you can filter or decide to see only certain types of information. In your example, you could have a view that only showed you recent "configuration" changes and this could be right next to a view that showed off the items to be watched every morning. Q: It's great to hear about customers using the software but is there any plan for future webinars to show what the products/installs look like? That would be very helpful.A: We don't have a webinar planned to show off the install process. However, we have a viewlet that's posted on Oracle Technology Network. You can see it here:http://www.oracle.com/technetwork/testcontent/wcs-install-098014.htmlAnd we've got excellent documentation that walks you through the steps here:http://download.oracle.com/docs/cd/E14571_01/install.1111/e12001/install.htmAnd there's a whole set of demos and examples of what WebCenter can do at this URL:http://www.oracle.com/technetwork/middleware/webcenter/release11-demos-097468.html Q: How do you anticipate managing metadata across the enterprise to make content findable?A: We need to first make sure we are all talking about the same thing when we use a word like "metadata". Here's why...  For a developer, metadata means information that describes key elements of the portal or application and what the portal or application can do. For content systems, metadata means key terms that provide a taxonomy or folksonomy about the information that is being indexed, ordered, and managed. For business intelligence systems, metadata means key terms that provide labels to groups of data that most non-mathematicians need to understand. And for SOA, metadata means labels for parts of the processes that business owners should understand that connect development terminology. There are also additional requirements for metadata to be available to the team building these new solutions as well as requirements to make this metadata available to the running system. These requirements are often separated by "design time" and "run time" respectively. So clearly, a general goal of managing metadata across the enterprise is very challenging. We've invested a huge amount of resources around Oracle Metadata Services (MDS) to be able to provide a more generic system for all of these elements. No other vendor has anything like this technology foundation in their products. This provides a huge benefit to our customers as they will now be able to find content, processes, people, and information from a common set of search interfaces with consistent enterprise wide results. Q: Can you give your definition of terms as to document and content, please?A: Content applies to a broad category of information from Word documents, presentations and reports through attachments to invoices and/or purchase orders. Content is essentially any type of digital asset including images, video, and voice. A document is just one type of content. Q: Do you have special integration tools to realize an interaction between UCM and WebCenter Spaces/Services?A: Yes, we've dedicated a whole team of engineers to exploit the key features of Oracle UCM within WebCenter.  While ensuring that WebCenter can connect to other non-Oracle systems, we've made sure that with the combined set of Oracle technology, no other solution can match the combined power and integration.  This is part of the Oracle Fusion Middleware strategy which is to provide best in class capabilities for Content and Portals.  When combined together, the synergy between the two products enables users to quickly add capabilities when they are needed.  For example, simple document sharing is part of the combined product offering, but if legal discovery or archiving is required, Oracle UCM product includes these capabilities that can be quickly added.  There's no need to move content around or add another system to support this, it's just a feature that gets turned on within Oracle UCM. Q: All customers have some interaction with their applications and have many older versions, how do you see some of these new Enterprise 2.0 capabilities adding value to existing enterprise application deployments?A: Just as Service Oriented Architectures allowed for connecting the processes of different applications systems to work together, there's a need for a similar approach with regards to these enterprise 2.0 capabilities. Oracle WebCenter is built on a core architecture that allows for SOA of these Enterprise 2.0 services so that one set of scalable services can be used and integrated directly into any type of application. In this way, users can get immediate value out of the Enterprise 2.0 capabilities without having to wait for the next major release or upgrade. These centrally managed WebCenter services expose a set of standard interfaces that make it extremely easy to add them into existing applications no matter what technology the application has been implemented. Q: We've heard about Oracle Next Generation applications called "Fusion Applications", can you tell me how all this works together?A: Oracle WebCenter powers the core collaboration and social computing services found within Fusion Applications. It is the core user experience technology for how all the application screens have been implemented. And the core concept of task flows allows for all the Fusion Applications modules to be adaptable and composable by business users and IT without needing to be a professional developer. Oracle WebCenter is at the heart of the new Fusion Applications. In addition, the same patterns and technologies are now being added to the existing applications including JD Edwards, Siebel, Peoplesoft, and eBusiness Suite. The core technology enables all these customers to have a much smoother upgrade path to Fusion Applications. They get immediate benefits of injecting new user interactions into their existing applications without having to completely move to Fusion Applications. And then when the time comes, their users will already be well versed in how the new capabilities work. Q: Does any of this work with non Oracle software? Other databases? Other application servers? etc.A: We have made sure that Oracle WebCenter delivers the broadest set of development choices so that no matter what technology you developers are using, WebCenter capabilities can be quickly and easily added to the site or application. In addition, we have certified Oracle WebCenter to run against non-Oracle databases like DB2 and SQLServer. We have stated plans for certification against MySQL as well. Later in CY 2011, Oracle will provide certification on non-Oracle application servers such as WebSphere and JBoss. Q: How do we balance User and IT requirements in regards to Enterprise 2.0 technologies?A: Wrong decisions are often made because employee knowledge is not tapped efficiently and opportunities to innovate are often missed because the right people do not work together. Collaboration amongst workers in the right business context is critical for success. While standalone Enterprise 2.0 technologies can improve collaboration for collaboration's sake, using social collaboration tools in the context of business applications and processes will improve business responsiveness and lead companies to a more competitive position. As these systems become more mission critical it is essential that they maintain the highest level of performance and availability while scaling to support larger communities. Q: What are the ways in which Enterprise 2.0 can improve business responsiveness?A: With a wide range of Enterprise 2.0 tools in the marketplace, CIOs need to deploy solutions that will meet the requirements from users as well as address the requirements from IT. Workers want a next-generation user experience that is personalized and aggregates their daily tools and tasks, while IT needs to ensure the solution is secure, scalable, flexible, reliable and easily integrated with existing systems. An open and integrated approach to deploying portals, content management, and collaboration can enhance your business by addressing both the needs of knowledge workers for better information and the IT mandate to conserve resources by simplifying, consolidating and centralizing infrastructure and administration.  

    Read the article

  • Top Reasons You Need A User Engagement Platform

    - by Michael Snow
    Guest post by: Amit Sircar, Senior Sales Consultant, Oracle Deliver complex enterprise functionality through a simple intuitive and unified User Interface (UI) The modern enterprise contains a wide range of applications that are used to manage the business and drive competitive advantages. Organizations respond by creating a complex structure that results in a functional and management grouping of users. Each of these groups of users requires access to multiple applications and information sources in order to perform their job functions. This leads to the lack of a unified view of enterprise information, inconsistent user interfaces and disjointed security. To be effective, portals must be designed from the end-user perspective, enabling the user to accomplish as many tasks as possible while visiting the fewest number of portals. This requires rethinking the way that portals are built, moving from a functional business unit perspective to a user-focused, process-oriented point of view. Oracle WebCenter provides the Common User Experience Architecture that allows organizations to seamlessly present a unified view of enterprise information tailored to a particular user’s role and preferences. This architecture provides the best practices, design patterns and delivery mechanism for myriad services, applications, and data sources.  In order to serve as a primary system of access, Oracle WebCenter also provides access to unstructured content and to other users via integrated search, service-oriented artifacts, content management, and collaboration tools. Provide a modern and engaging experience without modifying the core business application Web 2.0 technologies such as blogs, wikis, forums or social media sites are having a profound impact in the public internet.  These technologies can be leveraged by enterprises to add significant value to the business. Organizations need to integrate these technologies directly into their business applications while continuing to meet their security and governance needs. To deliver richer connections and become a more agile and intelligent business, WebCenter provides an enterprise portal platform that contains pre-integrated, standards-based Enterprise 2.0 services. These Enterprise 2.0 services can be easily accessed, integrated and utilized by users. By giving users the ability to use and integrate Enterprise 2.0 services such as tags, links, wikis, activities, blogs or social networking directly with their portals and applications, they are empowered to make richer connections, optimize their productivity, and ultimately increase the value of their applications. Foster a collaborative experience The organizational workplace has undergone a major change in the last decade. With increasing globalization and a distributed workforce, project teams may be physically separated by large distances. Online collaboration technologies are becoming a critical resource to enable virtual teams to share information and work together effectively. Oracle WebCenter delivers dynamic business communities with rich Services to empower teams to quickly and efficiently manage their information, applications, projects, and people without requiring IT assistance. It brings together the latest technology around Enterprise 2.0 and social computing, communities, personal productivity, and ad-hoc team interactions without any development effort. It enables the sharing and collaboration on team content, focusing an organization’s valuable resources on solving business problems, tapping into new ideas, and reducing time-to-market. Mobile Support The traditional workplace dynamics that required employees to access their work applications from their desktops have undergone a fundamental shift. Employees were used to primarily working from company offices and utilized an IT-issued computer for performing their job functions. With the introduction of flexible work hours and the growth of remote workers, more and more employees need the ability to remain productive even when they do not have access to a computer via the use of tablets and smartphones.  In addition, customers and citizens have come to expect 24x7 access to resources and websites from wherever they are located. Tablets and smartphones have empowered everyone to quickly access services they need anytime and from any place.  WebCenter provides out of the box capabilities to deliver the mobile experience in a seamless manner. Seeded device profiles and toolkits within WebCenter can be used to render the same web pages into multiple target devices such iPads, iPhones and android devices. Web designers can preview the portal using the built in simulator, make necessary updates and then deploy their UI design for the targeted device. Conclusion The competitive economy and resource constraints facing organizations today require them to find ways to make their applications, portals and Web sites more agile and intelligent and their knowledge workers more productive no matter where they are located. Organizations need to provide faster access to relevant information and resources, enhance existing applications and business processes with rich Enterprise 2.0 services, and seamlessly deliver content to mobile platforms. Oracle WebCenter successfully meets these challenges by providing the modern user experience platform for the enterprise and the Web.

    Read the article

  • Parner Webcast - Innovations in Products Program

    - by Richard Lefebvre
    We are pleased to invite you to join the Innovations in Products –webcast. Innovations in Products will present Oracle Applications' Product's new functions and features including sales positioning. The key objectives of these webcasts are to inspire System Integrator's implementation personnel to conduct successful after sales in their Customer projects. Innovations in Products will be presented on the 1st Monday of each quarter after the billable day (4:00 to 5:00 PM CET). The webcast is intended for System Integrator's Implementation Certified Specialists but Innovations in Products is open for other interested Oracle Applications system Integrator's personnel as well. At first, two Oracle representatives will discuss Oracle's contribution to Partners. Then you will see product breakout session followed by Q&A with Oracle Experts. Each session will last for maximum 1 hour. A Q&A document covering all questions and answers will be made available after the webcast. What are the Benefits for partners? Find out how Innovations in Products helps you to improve your after sales Discover new functions and features so you can enrich your Customers's solution Learn more about Oracle Applications products, especially sales positioning Hear crucial questions raised by colleague alike, learn from their interest Engage and present your questions to subject experts Be inspired of the richness of Oracle Application portfolio – for your and your customer’s benefit Note: Should you already be familiar with a specific Product, then choose another one. Doing so you would expand your knowledge of the overall Applications portfolio. Some presentations contain product demonstration, although these presentations are not intended to be extremely detailed technical presentations. Note: At the latter part of this email you have also 17 links into the recent Applications Products presentations and 6 links into the Public Sector Value Proposition presentations that were presented in Innovations in Industries -program. Product breakout sessions: Topics Speaker To Register Fusion Applications Technology and Extensibility: A next-generation platform that adapts to client needs. Matthew Johnson, Sr. Director, SCM Product Development, EMEA CLICK HERE Fusion Applications - Transforming your Back-Office Accounting Function: Changing how people work in back office functions to drive value add Liam Nolan, Director, ERP Product Development, EMEA CLICK HERE Fusion HCM & Talent Overview & Extensibility: A more in-depth look into a personalized HCM solution Synco Jonkeren, Vice-President HCM Product Development & Management, EMEA CLICK HERE Fusion HCM Compensation Planning: Compensate To Compete Rosie Warner, Director, HCM Sales Development CLICK HERE Enterprise PLM for the Product Value Chain: Oracle Enterprise PLM offers Industry specific solutions that cover the Product Value Chain Ulf Köster, Sales Development Leader Enterprise PLM, Oracle Western Europe CLICK HERE Oracle's Asset Management and Maintenance Solution: What you need to know to successfully implement Oracle Asset Management solutions within Oracle Installed Base Philip Carey, Asset Management and Maintenance Solution Specialist CLICK HERE For more details please visit Innovations in Products and other breakout sessions on OPN page. Delivery Format Innovations in Products –program is a series of FREE prerecorded Applications product presentations followed by Q&A. It will be delivered over the Web. Participants have the opportunity to submit questions during the web cast via chat and subject matter experts will provide verbal answers live. Innovations in Products consists of several parallel prerecorded product breakout sessions, each lasting for max. 1 hour. At first, two Oracle representatives will discuss Oracle’s contribution to Partners. Then you’ll see the product breakout sessions followed by Q&A with Oracle Experts. A Q&A document covering all questions and answers will be made available after the webcast. You can also see Innovations in Products afterwards as its content will be available online for the next 6-12 months. The next Innovations in Products web casts will be presented as follows: July 2nd 2012 October 1st 2012 January 14th 2013 April 8th 2013. Note: Depending on local network bandwidth please allow some seconds time the presentations to download. You might want to refresh your screen by pressing F5. Duration Maximum 1 hour For further information please contact me Markku Rouhiainen. Recent Innovations in Products presentations Applications Products presented on April the 2nd, 2012 Speaker To Register Fusion CRM: Effective, Efficient and Easy James Penfold , Senior Director, Applications Product Development and Product Management CLICK HERE Fusion HCM: Talent management overview performance, goals, talent review Jaime Losantos Viñolas, Director, HCM Sales Development CLICK HERE Distributed Order Management - Fusion SCM Solution Vikram K Singla, Business Development Director, Supply Chain Management Applications, UK CLICK HERE Oracle Transportation Management Dominic Regan, Senior Director Oracle Transportation Management EMEA CLICK HERE Oracle Value Chain Planning: Demantra Sales & Operation Planning and Demantra Demand Management Lionel Albert, Senior Director Value Chain Planning, EMEA CLICK HERE Oracle CX (Customer Experience) - formerly CEM: Powering Great Customer Experiences Maria Ramirez , CRM Presales Consultant, EPC CLICK HERE EPM 11.1.2.2 Overview Nicholas Cox , EMEA Sales Development Director - Enterprise Performance Management CLICK HERE Oracle Hyperion Profitability and Cost Management, 11.1.2.1 Daniela Lazar , Senior EPM Sales Consultant, EPC CLICK HERE January the 16th 2012 Speaker To Register CRM / ATG: Best-in-Class CRM & Commerce Maria Ramirez , Associate CRM Presales Consultant, EPC CLICK HERE CRM / Automate Business Rules for Maximum Efficiency with OPA (Oracle Policy Automation) Marco Nilo, Associate CRM Presales Consultant, EPC CLICK HERE CRM / InQuira Toby Baker, Principal Sales Consultant, CRM Product Specialist Team CLICK HERE EPM / Business Intelligence Foundation Suite – Sales and Product Updates Liviu Nitescu, Senior BI Sales Consultant, EPC CLICK HERE EPM / Hyperion Planning 11.1.2.1 - Sales & Product Updates Andreea Voinea, EPM Sales Consultant, EPC CLICK HERE ERP / JDE EnterpriseOne Fulfillment Management Overview Mirela Andreea Nasta , ERP Presales Consultant, EPC CLICK HERE ERP / Spotlights on iExpenses Elena Nita ,ERP Presales Consultant, EPC CLICK HERE MDM / Master Data Management Martin Boyd , Senior Director Product Strategy CLICK HERE Product break through session Fusion Applications Human Capital Management Rosie Warner , Director, HCM Sales Development CLICK HERE Recent Innovations in Industries Value Proposition presentations January the 16th 2012 Speaker To Register Process Modernisation Iemke Idsingh Public Sector Solutions Director CLICK HERE Shared Services Ann Smith Business Development Director, Shared Services CLICK HERE Strengthening Financial Discipline Whilst Delivering Cashable Savings Philippa Headley UK Sales Development Director Public Sector - EPM Solutions CLICK HERE Social Welfare Industry Solutions Christian Wernberg-Tougaard Industry Director - Social Welfare CLICK HERE Police Industry Solutions Jeff Penrose Solution Sales Director CLICK HERE Tax and Revenue Management Industry Solutions Andre van der Post Global Director - Tax Solutions and Strategy CLICK HERE  

    Read the article

  • NVIDIA x server - "sudo nvidia config" does not generate a working 'xorg.config'

    - by Mike
    I am over 18 hours deep on this challenge. I got to this point and am stuck. very stuck. Maybe you can figure it out? Ubuntu Version 12.04 LTS with all the updates installed. Problem: The default settings in "etc/X11/xorg.conf" that are generated by the "nvidia-xconfig" tool, do not allow the NVIDIA x server to connect to the driver in my "System Settings Additional Driver window". (that's how I understand it. Lots of information below). Symptoms of Problem "System Settings Additional Driver" window has drivers, but the nvidia x server cannot connect/utilize any of the 4 drivers. the drivers are activated, but not in use. When I go to "System Tools Administration NVIDIA x server settings" I get an error that basically tells me to create a default file to initialize the NVIDIA X server (screen shot below). This is the messages the terminal gives after running a "sudo nvidia-xconfig" command for the first time. It seems that the generated file by the tool i just ran is generating a bad/unusable file: If I run the "sudo nvidia-xconfig" command again, I wont get an error the second time. However when I reboot, the default file that is generated (etc/X11/xorg.conf) simply puts the screen resolution at 800 x 600 (or something big like that). When I try to go to NVIDIA x server settings I am greeted with the same screen as the screen shot as in symptom 2 (no option to change the resolution). If I try to go to "system settings display" there are no other resolutions to choose from. At this point I must delete the newly minted "xorg.conf" and reinstate the original in its place. Here are the contents of the "xorg.conf" that is generated first (the one missing required information): # nvidia-xconfig: X configuration file generated by nvidia-xconfig # nvidia-xconfig: version 304.88 (buildmeister@swio-display-x86-rhel47-06) Wed Mar 27 15:32:58 PDT 2013 Section "ServerLayout" Identifier "Layout0" Screen 0 "Screen0" InputDevice "Keyboard0" "CoreKeyboard" InputDevice "Mouse0" "CorePointer" EndSection Section "Files" EndSection Section "InputDevice" # generated from default Identifier "Mouse0" Driver "mouse" Option "Protocol" "auto" Option "Device" "/dev/psaux" Option "Emulate3Buttons" "no" Option "ZAxisMapping" "4 5" EndSection Section "InputDevice" # generated from default Identifier "Keyboard0" Driver "kbd" EndSection Section "Monitor" Identifier "Monitor0" VendorName "Unknown" ModelName "Unknown" HorizSync 28.0 - 33.0 VertRefresh 43.0 - 72.0 Option "DPMS" EndSection Section "Device" Identifier "Device0" Driver "nvidia" VendorName "NVIDIA Corporation" EndSection Section "Screen" Identifier "Screen0" Device "Device0" Monitor "Monitor0" DefaultDepth 24 SubSection "Display" Depth 24 EndSubSection EndSection Hardware: I ran the "lspci|grep VGA". There results are: 00:02.0 VGA compatible controller: Intel Corporation 2nd Generation Core Processor Family Integrated Graphics Controller (rev 09) 01:00.0 VGA compatible controller: NVIDIA Corporation GF108 [Quadro 1000M] (rev a1) More Hardware info: Ram: 16GB CPU: Intel Core i7-2720QM @2.2GHz * 8 Other: 64 bit. This is a triple boot computer and not a VM. Attempts With Not Success on My End: 1) Tried to append the "xorg.conf" with what I perceive is missing information and obviously it didn't fly. 2) All the other stuff I tried got me to this point. 3) See if this link is helpful to you (I barely get it, but i get enough knowing that a smarter person might find this useful): http://manpages.ubuntu.com/manpages/lucid/man1/nvidia-xconfig.1.html 4) I am completely new to Linux (40 hours over past week), but not to programming. However I am very serious about changing over to Linux. When you respond (I hope someone responds...) please respond in a way that a person new to Linux can understand. 5) By the way, the reason I am in this mess is because I MUST have a second monitor running from my laptop, and "System Settings Display" doesn't recognize my second display. I know it is possible to make the second display work in my system, because when I boot from the install CD, I perform work on the native laptop monitor, but the second monitor shows a purple screen with Ubuntu in the middle, so I know the VGA port is sending a signal out. If this is too much for you to tackle please suggest an alternative method to get a second display. I don't want to go to windows but I cannot have a single display. I am really fudged here. I hope some smart person can help. Thanks in advance. Mike. **********************EDIT #1********************** More Details About Graphics Card I was asked "which brand of nvidia-card do you have exactly?" Here is what I did to provide more info (maybe relevant, maybe not, but here is everything): 1) Took my Lenovo W520 right apart to see if there is an identifier on the actual card. However I realized that if I get deep enough to take a look, the laptop "won't like it". so I put it back together. Figuring out the card this way is not an option for me right now. 2) (My computer is triple boot) I logged into Win7 and ran 'dxdiag' command. here is the screen shot: 3) I tried to look on the lenovo website for more details... but no luck. I took a look at my receipts and here is info form receipt: System Unit: W520 NVIDIA Quadro 1000M 2GB 4) In win7 I went to the NVIDIA website and used the option to have my card 'scanned' by a Java applet to determine the latest update for my card. I tried the same with Ubuntu but I can't get the applet to run. Here is the recommended driver from from the NVIDIA Applet for my card for Win7 (I hope this shines some light on the specifics of the card): Quadro/NVS/Tesla/GRID Desktop Driver Release R319 Version: 320.00 WHQL Release Date: 3.5.2013 5) Also I went on the NVIDIA driver search and looked through every possible combination of product type + product series + product to find all the combinations that yield a 1000M card. My card is: Product Type: Quadro Product Series: Quadro Series (Notebooks) Product: 1000M ***********************EDIT #2******************* Additional Symptoms Another question that generated more symptoms I previously didn't mention was: "After generating xorg.conf by nvidia-xconfig, go to additional drivers, do you see nvidia-304?" 1) I took a screen shot of the "additional drivers" right after generating xorg.conf by nvidia-xconfig. Here it is: 2) Then I did a reboot. Now Ubuntu is 600 x 800 resolution. When I logged in after the computer came up I got an error (which I always get after generating xorg.conf by nvidia-xconfig and rebooting) 3) To finally answer the question - No. There is no "NVIDIA-304" driver. Screen shot of additional drivers after generating xorg.conf by nvidia-xconfig and rebooting : At this point I revert to the original xorg.conf and delete the xorg.conf generated by Nvidia.

    Read the article

  • Five Things Learned at the BSR Conference in San Francisco on Nov 2nd-4th

    - by Evelyn Neumayr
    The BSR Conference 2011—“Redefining Leadership”—held from Nov 2nd to Nov 4th in San Francisco, with Oracle as one of the main sponsors, saw senior business executives, civil society representatives, and other experts from around the world gathering to share strategies and insights on the future of sustainability. The general conference sessions kicked off on November 2nd with a plenary address by former U.S. Vice President Al Gore. Other sessions were presented by CEOs of the caliber of Carl Bass (Autodesk), Brian Dunn (Best Buy), Carlos Brito (Anheuser-Busch InBev) and Ofra Strauss (Strauss Group). Here are five key highlights from the conference: 1.      The main leadership challenge is integrating sustainability into core business functions and overcoming short-termism. The “BSR GlobeScan State of Sustainable Business Poll 2011” - a survey of nearly 500 business leaders from 300 member companies - shows that 84% of respondents are optimistic that global businesses will embrace CSR/sustainability as part of their core strategies and operations in the next five years but consider integrating sustainability into their core business functions the key challenge. It is still difficult for many companies that are committed to the sustainability agenda to find investors that understand the long-term implications and as Al Gore said “Many companies are given the signal by the investors that it is the short term results that matter and that is a terribly debilitating force in the market.” 2.      Companies are required to address increasing compliance requirements and transparency in their supply chain, especially in relation with conflict minerals legislation and water management. The Dodd-Frank legislation, OECD guidelines, and the upcoming Securities and Exchange Commission (SEC) rules require companies to monitor upstream the sourcing of tin, tantalum, tungsten, and gold, but given the complexity of this issue companies need to collaborate and partner with peer companies in their industry as well as in other industries to understand how to address conflict minerals in their supply chains. The Institute of Public and Environmental Affairs’ (IPE) China Water Pollution Map enables the public to access thousands of environmental quality, discharge, and infraction records released by various government agencies. Empowered with this information, the public has the opportunity to place greater pressure on polluting companies to comply with environmental standards and create solutions to improve their performance. 3.      A new standard for reporting on supply chain greenhouse gas emissions is available. The New “Scope 3” Supply Chain Greenhouse Gas Inventory Standard, released on October 4th 2011, is the only international greenhouse gas emissions standard that accounts for the full lifecycle of a company’s products. It provides a framework for companies to account for indirect emissions outside of energy use, such as transportation, manufacturing, and distribution, and it incorporates both upstream and downstream impacts of a product. With key investors now listing supplier vulnerability to rising energy prices and disruptions of service as a key concern, greenhouse gas (GHG) management isn’t just for leading companies but a necessity for any business. 4.      Environmental, social, and corporate governance (ESG) reporting is becoming increasingly important to investors and other stakeholders. While European investors have traditionally driven the ESG agenda, U.S. investors are increasingly including ESG data in their analyses. This trend will likely increase as stakeholders continue to demand that an ESG lens be applied to their investments. Investors are increasingly looking to partner on sustainability, as they see the benefits of ESG providing significant returns on investment. 5.      Software companies are offering an increasing variety of solutions to help drive changes and measure performance internally, in supply chains, and across peer companies. The significant challenge is how to integrate different software systems to facilitate decision-making based on a holistic understanding of trade-offs. Jon Chorley, Chief Sustainability Officer and Vice President, Supply Chain Management Product Strategy at Oracle was a panelist in the “Trends in Sustainability Software” session and commented that, “How we think about our business decisions really comes down to how we think about cost. And as long as we don’t assign a cost to things that have an environmental impact or social impact, then we make decisions based on incomplete information. If we could include that in the process that determines ‘Is this product profitable? we would then have a much better decision.” For more information on BSR visit www.brs.org. You can also view highlights of the plenary session at http://www.bsr.org/en/bsr-conference/session-summaries/2011. Oracle is proud to be a sponsor of this BSR conference. By Elena Avesani, Principal Product Strategy Manager, Oracle          

    Read the article

  • A little primer on using TFS with a small team

    - by johndoucette
    The scenario; A small team of 3 developers mostly in maintenance mode with traditional ASP.net, classic ASP, .Net integration services and utilities with the company’s third party packages, and a bunch of java-based Coldfusion web applications all under Visual Source Safe (VSS). They are about to embark on a huge SharePoint 2010 new construction project and wanted to use subversion instead VSS. TFS was a foreign word and smelled of “high cost” and of an “over complicated process”. Since they had no preconditions about the old TFS versions (‘05 & ‘08), it was fun explaining how simple it was to install a TFS server and get the ball rolling, with or without all the heavy stuff one sometimes associates with such a huge and powerful application management lifecycle product. So, how does a small team begin using TFS? 1. Start by using source control and migrate current VSS source trees into TFS. You can take the latest version or migrate the entire version history. It’s up to you on whether you want a clean start or need quick access to all the version notes and history of the bits. 2. Since most shops are mainly in maintenance mode with existing applications, begin using bug workitems for everything. When you receive an issue/bug from your current tracking system, manually enter the workitem in TFS right through Visual Studio. You can automate the integration to the current tracking system later or replace it entirely. Believe me, this thing is powerful and can handle even the largest of help desks. 3. With new construction, begin work with requirements and task workitems and follow the traditional sprint-based development lifecycle. Obviously, some minor training will be needed, but don’t fear, this is very intuitive and MSDN has a ton of lesson based labs and videos. 4. For the java developers, use the new Team Explorer Everywhere 2010 plugin (recently known as Teamprise). There is a seamless interface in Eclipse, but also a good command-line utility for other environments such as Dreamweaver. 5. Wait to fully integrate the whole workitem/project management/testing process until your team is familiar with the integrated workitems for bugs and code. After a while, you will see the team wanting more transparency into the work they are all doing and naturally, everyone will want workitems to help them organize the chaos! 6. Management will be limited in the value of the reports until you have a fully blown implementation of project planning, construction, build, deployment and testing. However, there are some basic “bug rate” reports and current backlog listings that can provide good information. Some notable explanations of TFS; Work Item Tracking and Project Management - A workitem represents the unit of work within the system which enables tracking of all activities produced by a user, whether it is a developer, business user, project manager or tester. The properties of a workitem such as linked changesets (checked-in code), who updated the data and when, the states and reasons for change, are all transitioned to a data warehouse within TFS for reporting purposes. A workitem can be defines as a "bug", "requirement", test case", or a "change request". They drive the work effort by the individual assigned to it and also provide a key role in defining what needs to be done. Workitems are the things the team needs to do to accomplish a goal. Test Case Management - Starting with a workitem known as a "test case", a tester (or developer) can now author and manage test cases within a formal test plan subsystem. Although TFS supports the test case workitem type, there is a new product known as the VS Test Professional 2010 which allows a tester to facilitate manual tests including fast forwarding steps in the process to arrive at the assertion point quickly. This repeatable process provides quick regression tests and can be conducted by the business user to ensure completeness during UAT. In addition, developers no longer can provide a response to a bug with the line "cannot reproduce". With every test run, attachments including the recorded session, captured environment configurations and settings, screen shots, intellitrace (debugging history), and in some cases if the lab manager is being used, a snapshot of the tested environment is available. Version Control - A modern system allowing shared check-in/check-out, excellent merge conflict resolution, Shelvesets (personal check-ins), branching/merging visualization, public workspaces, gated check-ins, security hierarchy capabilities, and changeset/workitem tracking. Knowing what was done with the code by any developer has become much easier to picture and resolve issues. Team Build - Automate the compilation process whether you need it to be whenever a developer checks-in code, periodically such as nightly builds for testers in the morning, or manual builds to be deployed into production. Each build can run through pre-determined tests, perform code analysis to see if the developer conforms to the team standards, and reject the build if either fails. Project Portal & Reporting - Provide management with a dashboard with insight into the project(s). "Where are we" in each step of the way including past iterations and the current burndown rate. Enabling this feature is easy as it seamlessly interfaces with existing SharePoint implementations.

    Read the article

  • Deep in the Heart of Texas

    - by Applications User Experience
    Author: Erika Webb, Manager, Fusion Applications UX User Assistance When I was first working in the usability field, the only way I could consider conducting a usability study was to bring a potential user to a lab environment where I could show them whatever I was interested in learning more about and ask them questions. While I hate to reveal just how long I have been working in this field, let's just say that pads of paper and a stopwatch were key tools for any test I conducted. Over the years, I have worked in simple labs with basic video taping equipment and not much else, and I have worked in corporate environments with sophisticated usability labs and state-of-the-art equipment. Years ago, we conducted all usability studies at the location of the user. If we wanted to see if there were any differences between users in New York, Chicago, and Los Angeles, we went to those places to run the test. A lab environment is very useful for many test situations. However, there has always been a debate in the usability field about whether bringing someone into a lab environment, however friendly we make it, somehow intrinsically changes the behavior of the user as compared to having them work in their own environment, at their own desk, and on their own computer. We developed systems to create a portable usability lab, so that we could go to the users that we needed to test.  Do lab environments change user behavior patterns? Then 9/11 hit. You may not remember, but no planes flew for weeks afterwards. Companies all over the world couldn't fly-in employees for meetings. Suddenly, traveling to the location of the users had an additional difficulty. The company I was working for at the time had usability specialists stuck in New York for days before they could finally rent a car and drive home to Colorado. This changed the world pretty suddenly, and technology jumped on the change. Companies offering Internet meeting tools were strugglinguntil no one could travel. The Internet boomed with collaboration tools that enabled people to work together wherever they happened to be. This change in technology has made a huge difference in my world. We use collaborative tools to bring our product concepts and ideas to the user across the Internet. As a global company, we benefit from having users from all over the world inform our designs. We now run usability studies with users all over the world in a single day, a feat we couldn't have accomplished 10 years ago by plane! Other technology companies have started to do more of this type of usability testing, since the tools have improved so dramatically. Plus, in our busy world, it's not always easy to find users who can take the time away from their jobs to come to our labs. reaching users where it is convenient for them greatly improves the odds that people do participate. I manage a team of usability specialists who live in India and California, whlie I live in Colorado. We have wonderful labs that we bring users into to show them our products. But very often, we run our studies remotely. We used to take the lab to the users now we use the labs, but we let the users stay where they are. We gain users who might not have been able to leave work to come to our labs, and they get to use the system they are familiar with. And we gain users nearly anywhere that we can set up an Internet connection, as long as the users have a phone, a broadband connection, and a compatible Web browser (with no pop-up blockers). After we recruit participants in a traditional manner, we send them an invitation to participate through the use of a telephone conference call and Web conferencing tool. At Oracle, we use Oracle Web Conference part of Oracle Collaboration Suite, which enables us to give the user control of the mouse, while we present a prototype or wireframe pictures. We can record the sessions over the Web and phone conference. We send the users instructions, plus tips to ensure that we won't have problems sharing screens. In some cases, when time is tight, we even run a five-minute "test session" with users a day in advance to be sure that we can connect. Prior to the test, we send users a participant script that contains information about the study, including any questionnaires. This is exactly the same script we give to participants who come to the labs. We ask users to print this before the beginning of the session. We generally run these studies by having a usability engineer in our usability labs, so that we can record the session as though the user were in the lab with us. Roughly 80% of our application software usability testing at Oracle is performed using remote methods. The probability of getting a   remote test participant decreases the higher up the person is in the target organization. We have a methodology checklist available to help our usability engineers work through the remote processes.

    Read the article

  • How to Never Use iTunes With Your iPhone, iPad, or iPod Touch

    - by Chris Hoffman
    iTunes isn’t an amazing program on Windows. There was a time when Apple device users had to plug their devices into their PCs or Macs and use iTunes for device activation, updates, and syncing, but iTunes is no longer necessary. Apple still allows you to use iTunes for these things, but you don’t have to. Your iOS device can function independently from iTunes, so you should never be forced to plug it into a PC or Mac. Device Activation When the iPad first came out, it was touted as a device that could replace full PCs and Macs for people who only needed to perform light computing tasks. Yet, to set up a new iPad, users had to plug it into a PC or Mac running iTunes and use iTunes to activate the device. This is no longer necessary. With new iPads, iPhones, and iPod Touches, you can simply go through the setup process after turning on your new device without ever having to plug it into iTunes. Just connect to a Wi-Fi or cellular data network and log in with your Apple ID when prompted. You’ll still see an option that allows you to activate the device via iTunes, but this should only be necessary if you don’t have a wireless Internet connection available for your device. Operating System Updates You no longer have to use Apple’s iTunes software to update to a new version of Apple’s iOS operating system, either. Just open the Settings app on your device, select the General category, and tap Software Update. You’ll be able to update right from your device without ever opening iTunes. Purchased iTunes Media Apple allows you to easily access content you’ve purchased from the iTunes Store on any device. You don’t have to connect your device to your computer and sync via iTunes. For example, you can purchase a movie from the iTunes Store. Then, without any syncing, you can open the iTunes Store app on any of your iOS devices, tap the Purchased section, and see stuff you’ve downloaded. You can download the content right from the store to your device. This also works for apps — apps you purchase from the App Store can be accessed in the Purchased section on the App Store on your device later. You don’t have to sync apps from iTunes to your device, although iTunes still allows you to. You can even set up automatic downloads from the iTunes & App Store settings screen. This would allow you to purchase content on one device and have it automatically download to your other devices without any hassle. Music Apple allows you to re-download purchased music from the iTunes Store in the same way. However, there’s a good chance you have your own music you didn’t purchase from iTunes. Maybe you spent time ripping it all from your old CDs and you’ve been syncing it to your devices via iTunes ever since. Apple’s solution for this is named iTunes Match. This feature isn’t free, but it’s not a bad deal at all. For $25 per year, Apple allows you to upload all your music to your iCloud account. You can then access all your music from any iPhone, IPad, or iPod Touch. You can stream all your music — perfect if you have a huge library and little storage on your device — and choose which songs you want to download to your device for offline use. When you add additional music to your computer, iTunes will notice it and upload it using iTunes Match, making it available for streaming and downloading directly from your iOS devices without any syncing. This feature is named iTunes Match because it doesn’t just upload music — if Apple already has a song you upload, it will “match” your song with Apple’s copy. This means you may get higher-quality versions of your songs if you ripped them from CD at a lower bitrate. Podcasts You don’t have to use iTunes to subscribe to podcasts and sync them to your devices. Even if you have a lowly iPod Touch, you can install APple’s Podcasts app from the app store. Use it to subscribe to podcasts and configure them to automatically download directly to your device. You can use other podcast apps for this, too. Backups You can continue backing up your device’s data through iTunes, generating local backups that are stored on your computer. However, new iOS devices are configured to automatically back up their data to iCloud. This happens automatically in the background without you even having to think about it, and you can restore such backups when setting up a device simply by logging in with your Apple ID. Personal Data In the days of PalmPilots, people would use desktop programs like iTunes to sync their email, contacts, and calendar events with their mobile devices. You probably shouldn’t have to sync this data form your computer. Just sign into your email account — for example, a Gmail account — on your device and iOS will automatically pull your email, contacts, and calendar events from your associated account. Photos Rather than connecting your iOS device to your computer and syncing photos from it, you can use an app that automatically uploads your photos to a web service. Dropbox, Google+, and even Flickr all have this feature in their apps. You’ll be able to access your photos from any computer and have a backup copy without any syncing required. You may still need to use iTunes if you want to sync local music without paying for iTunes Match or copy local video files to your device. Copying large local files over is the only real scenario where you’d need iTunes. If you don’t need to copy such files over, you can go ahead and uninstall iTunes from your Windows PC if you like. You shouldn’t need it.     

    Read the article

  • Row Count Plus Transformation

    As the name suggests we have taken the current Row Count Transform that is provided by Microsoft in the Integration Services toolbox and we have recreated the functionality and extended upon it. There are two things about the current version that we thought could do with cleaning up Lack of a custom UI You have to type the variable name yourself In the Row Count Plus Transformation we solve these issues for you. Another thing we thought was missing is the ability to calculate the time taken between components in the pipeline. An example usage would be that you want to know how many rows flowed between Component A and Component B and how long it took. Again we have solved this issue. Credit must go to Erik Veerman of Solid Quality Learning for the idea behind noting the duration. We were looking at one of his packages and saw that he was doing something very similar but he was using a Script Component as a transformation. Our philosophy is that if you have to write or Copy and Paste the same piece of code more than once then you should be thinking about a custom component and here it is. The Row Count Plus Transformation populates variables with the values returned from; Counting the rows that have flowed through the path Returning the time in seconds between when it first saw a row come down this path and when it saw the final row. It is possible to leave both these boxes blank and the component will still work.   All input columns are passed through the transformation unaltered, you are not permitted to change or add to the inputs or outputs of this component. Optionally you can set the component to fire an event, which happens during the PostExecute phase of the execution. This can be useful to improve visibility of this information, such that it is captured in package logging, or can be used to drive workflow in the case of an error event. Properties Property Data Type Description OutputRowCountVariable String The name of the variable into which the amount of row read will be passed (Optional). OutputDurationVariable String The name of the variable into which the duration in seconds will be passed. (Optional). EventType RowCountPlusTransform.EventType The type of event to fire during post execute, included in which are the row count and duration values. RowCountPlusTransform.EventType Enumeration Name Value Description None 0 Do not fire any event. Information 1 Fire an Information event. Warning 2 Fire a Warning event. Error 3 Fire an Error event. Installation The component is provided as an MSI file which you can download and run to install it. This simply places the files on disk in the correct locations and also installs the assemblies in the Global Assembly Cache as per Microsoft’s recommendations. You may need to restart the SQL Server Integration Services service, as this caches information about what components are installed, as well as restarting any open instances of Business Intelligence Development Studio (BIDS) / Visual Studio that you may be using to build your SSIS packages. For 2005/2008 Only - Finally you will have to add the transformation to the Visual Studio toolbox manually. Right-click the toolbox, and select Choose Items.... Select the SSIS Data Flow Items tab, and then check the Row Count Plus Transformation in the Choose Toolbox Items window. This process has been described in detail in the related FAQ entry for How do I install a task or transform component? We recommend you follow best practice and apply the current Microsoft SQL Server Service pack to your SQL Server servers and workstations, and this component requires a minimum of SQL Server 2005 Service Pack 1. Downloads The Row Number Transformation is available for SQL Server 2005, SQL Server 2008 (includes R2) and SQL Server 2012. Please choose the version to match your SQL Server version, or you can install multiple versions and use them side by side if you have more than one version of SQL Server installed. Row Count Plus Transformation for SQL Server 2005 Row Count Plus Transformation for SQL Server 2008 Row Count Plus Transformation for SQL Server 2012 Version History SQL Server 2012 Version 3.0.0.6 - SQL Server 2012 release. Includes upgrade support for both 2005 and 2008 packages to 2012. (5 Jun 2012) SQL Server 2008 Version 2.0.0.5 - SQL Server 2008 release. (15 Oct 2008) SQL Server 2005 Version 1.1.0.43 - Bug fix for duration. For long running processes the duration second count may have been incorrect. (8 Sep 2006) Version 1.1.0.42 - SP1 Compatibility Testing. Added the ability to raise an event with the count and duration data for easier logging or workflow. (18 Jun 2006) Version 1.0.0.1 - SQL Server 2005 RTM. Made available as general public release. (20 Mar 2006) Screenshot Troubleshooting Make sure you have downloaded the version that matches your version of SQL Server. We offer separate downloads for SQL Server 2005, SQL Server 2008 and SQL Server 2012. If you get an error when you try and use the component along the lines of The component could not be added to the Data Flow task. Please verify that this component is properly installed.  ... The data flow object "Konesans ..." is not installed correctly on this computer, this usually indicates that the internal cache of SSIS components needs to be updated. This is held by the SSIS service, so you need restart the the SQL Server Integration Services service. You can do this from the Services applet in Control Panel or Administrative Tools in Windows. You can also restart the computer if you prefer. You may also need to restart any current instances of Business Intelligence Development Studio (BIDS) / Visual Studio that you may be using to build your SSIS packages. Once installation is complete you need to manually add the task to the toolbox before you will see it and to be able add it to packages - How do I install a task or transform component?

    Read the article

  • Need help with testdisk output

    - by dan
    I had (note the past tense) an ubuntu 12.04 system with separate partitions for the base and /home directories. It started acting wonky, so I decided to do a reinstall with 12.10, intending just to do a reinstall to the base partition. After several seconds, I realize that the installer was repartitioning the drive and reinstalling, so I pulled the power cord. I'm now trying to recover as much as I can with testdisk, but it seems that testdisk is finding 100 unique partitions when I run it - they mostly tend to be HFS+ or solaris /home (which I think is just an ext4; I've never had solaris on the machine). I've pasted an abbreviated version of the testdisk output below (first ~100 lines, and then ~100 lines from the middle of the output). Is there a way to combine or recreate the partitions and then data recovery, or some other way maximize what I can recover (ideally as much of the file system as possible)? I really only care about what was in the /home directory - I'd rather not use photorec since I don't have another 2 TB HD lying around to recover to. Thanks, Dan Mon Dec 10 06:03:00 2012 Command line: TestDisk TestDisk 6.13, Data Recovery Utility, November 2011 Christophe GRENIER <[email protected]> http://www.cgsecurity.org OS: Linux, kernel 3.2.34-std312-amd64 (#2 SMP Sat Nov 17 08:06:32 UTC 2012) x86_64 Compiler: GCC 4.4 Compilation date: 2012-11-27T22:44:52 ext2fs lib: 1.42.6, ntfs lib: libntfs-3g, reiserfs lib: 0.3.1-rc8, ewf lib: none /dev/sda: LBA, HPA, LBA48, DCO support /dev/sda: size 3907029168 sectors /dev/sda: user_max 3907029168 sectors /dev/sda: native_max 3907029168 sectors Warning: can't get size for Disk /dev/mapper/control - 0 B - CHS 1 1 1, sector size=512 /dev/sr0 is not an ATA disk Hard disk list Disk /dev/sda - 2000 GB / 1863 GiB - CHS 243201 255 63, sector size=512 - WDC WD20EARS-00J2GB0, S/N:WD-WCAYY0075071, FW:80.00A80 Disk /dev/sdb - 1013 MB / 967 MiB - CHS 1014 32 61, sector size=512 - Generic Flash Disk, FW:8.07 Disk /dev/sr0 - 367 MB / 350 MiB - CHS 179470 1 1 (RO), sector size=2048 - PLDS DVD+/-RW DH-16AAS, FW:JD12 Partition table type (auto): Intel Disk /dev/sda - 2000 GB / 1863 GiB - WDC WD20EARS-00J2GB0 Partition table type: EFI GPT Analyse Disk /dev/sda - 2000 GB / 1863 GiB - CHS 243201 255 63 Current partition structure: Bad GPT partition, invalid signature. search_part() Disk /dev/sda - 2000 GB / 1863 GiB - CHS 243201 255 63 recover_EXT2: s_block_group_nr=0/14880, s_mnt_count=5/4294967295, s_blocks_per_group=32768, s_inodes_per_group=8192 recover_EXT2: s_blocksize=4096 recover_EXT2: s_blocks_count 487593984 recover_EXT2: part_size 3900751872 MS Data 2048 3900753919 3900751872 EXT4 Large file Sparse superblock, 1997 GB / 1860 GiB Linux Swap 3900755968 3907028975 6273008 SWAP2 version 1, 3211 MB / 3062 MiB Results P MS Data 2048 3900753919 3900751872 EXT4 Large file Sparse superblock, 1997 GB / 1860 GiB P Linux Swap 3900755968 3907028975 6273008 SWAP2 version 1, 3211 MB / 3062 MiB interface_write() 1 P MS Data 2048 3900753919 3900751872 2 P Linux Swap 3900755968 3907028975 6273008 search_part() Disk /dev/sda - 2000 GB / 1863 GiB - CHS 243201 255 63 recover_EXT2: s_block_group_nr=0/14880, s_mnt_count=5/4294967295, s_blocks_per_group=32768, s_inodes_per_group=8192 recover_EXT2: s_blocksize=4096 recover_EXT2: s_blocks_count 487593984 recover_EXT2: part_size 3900751872 MS Data 2048 3900753919 3900751872 EXT4 Large file Sparse superblock, 1997 GB / 1860 GiB block_group_nr 1 recover_EXT2: "e2fsck -b 32768 -B 4096 device" may be needed recover_EXT2: s_block_group_nr=1/14880, s_mnt_count=0/4294967295, s_blocks_per_group=32768, s_inodes_per_group=8192 recover_EXT2: s_blocksize=4096 recover_EXT2: s_blocks_count 487593984 recover_EXT2: part_size 3900751872 MS Data 2046 3900753917 3900751872 EXT4 Large file Sparse superblock Backup superblock, 1997 GB / 1860 GiB block_group_nr 1 recover_EXT2: "e2fsck -b 32768 -B 4096 device" may be needed recover_EXT2: s_block_group_nr=1/14880, s_mnt_count=0/4294967295, s_blocks_per_group=32768, s_inodes_per_group=8192 recover_EXT2: s_blocksize=4096 recover_EXT2: s_blocks_count 487593984 recover_EXT2: part_size 3900751872 MS Data 2048 3900753919 3900751872 EXT4 Large file Sparse superblock Backup superblock, 1997 GB / 1860 GiB block_group_nr 1 recover_EXT2: "e2fsck -b 32768 -B 4096 device" may be needed recover_EXT2: s_block_group_nr=1/14584, s_mnt_count=0/27, s_blocks_per_group=32768, s_inodes_per_group=8192 recover_EXT2: s_blocksize=4096 recover_EXT2: s_blocks_count 477915164 recover_EXT2: part_size 3823321312 MS Data 4094 3823325405 3823321312 EXT4 Large file Sparse superblock Backup superblock, 1957 GB / 1823 GiB block_group_nr 1 ....snip...... MS Data 2046 3900753917 3900751872 EXT4 Large file Sparse superblock Backup superblock, 1997 GB / 1860 GiB MS Data 2048 3900753919 3900751872 EXT4 Large file Sparse superblock, 1997 GB / 1860 GiB MS Data 4094 3823325405 3823321312 EXT4 Large file Sparse superblock Backup superblock, 1957 GB / 1823 GiB MS Data 4096 3823325407 3823321312 EXT4 Large file Sparse superblock Backup superblock, 1957 GB / 1823 GiB MS Data 7028840 7033383 4544 FAT12, 2326 KB / 2272 KiB Mac HFS 67856948 67862179 5232 HFS+ found using backup sector!, 2678 KB / 2616 KiB Mac HFS 67862176 67867407 5232 HFS+, 2678 KB / 2616 KiB Mac HFS 67862244 67867475 5232 HFS+ found using backup sector!, 2678 KB / 2616 KiB Mac HFS 67867404 67872635 5232 HFS+, 2678 KB / 2616 KiB Mac HFS 67867472 67872703 5232 HFS+, 2678 KB / 2616 KiB Mac HFS 67872700 67877931 5232 HFS+, 2678 KB / 2616 KiB Mac HFS 67937834 67948067 10234 [EasyInstall_OSX] HFS found using backup sector!, 5239 KB / 5117 KiB Mac HFS 67938012 67948155 10144 HFS+ found using backup sector!, 5193 KB / 5072 KiB Mac HFS 67948064 67958297 10234 [EasyInstall_OSX] HFS, 5239 KB / 5117 KiB Mac HFS 67948070 67958303 10234 [EasyInstall_OSX] HFS found using backup sector!, 5239 KB / 5117 KiB Mac HFS 67948152 67958295 10144 HFS+, 5193 KB / 5072 KiB Mac HFS 67958292 67968435 10144 HFS+, 5193 KB / 5072 KiB Mac HFS 67958300 67968533 10234 [EasyInstall_OSX] HFS, 5239 KB / 5117 KiB Mac HFS 67992596 67997827 5232 HFS+ found using backup sector!, 2678 KB / 2616 KiB Mac HFS 67997824 68003055 5232 HFS+, 2678 KB / 2616 KiB Mac HFS 67997892 68003123 5232 HFS+ found using backup sector!, 2678 KB / 2616 KiB Mac HFS 68003052 68008283 5232 HFS+, 2678 KB / 2616 KiB Mac HFS 68003120 68008351 5232 HFS+, 2678 KB / 2616 KiB Mac HFS 68008348 68013579 5232 HFS+, 2678 KB / 2616 KiB Solaris /home 84429840 123499141 39069302 UFS1, 20 GB / 18 GiB Solaris /home 84429952 123499253 39069302 UFS1, 20 GB / 18 GiB Solaris /home 84493136 123562437 39069302 UFS1, 20 GB / 18 GiB Solaris /home 84493248 123562549 39069302 UFS1, 20 GB / 18 GiB Solaris /home 84566088 123635389 39069302 UFS1, 20 GB / 18 GiB Solaris /home 84566200 123635501 39069302 UFS1, 20 GB / 18 GiB Solaris /home 84571232 123640533 39069302 UFS1, 20 GB / 18 GiB Solaris /home 84571344 123640645 39069302 UFS1, 20 GB / 18 GiB Solaris /home 84659952 123729253 39069302 UFS1, 20 GB / 18 GiB Solaris /home 84660064 123729365 39069302 UFS1, 20 GB / 18 GiB Solaris /home 84690504 123759805 39069302 UFS1, 20 GB / 18 GiB Solaris /home 84690616 123759917 39069302 UFS1, 20 GB / 18 GiB Solaris /home 84700424 123769725 39069302 UFS1, 20 GB / 18 GiB Solaris /home 84700536 123769837 39069302 UFS1, 20 GB / 18 GiB Solaris /home 84797720 123867021 39069302 UFS1, 20 GB / 18 GiB Solaris /home 84797832 123867133 39069302 UFS1, 20 GB / 18 GiB Solaris /home 84812544 123881845 39069302 UFS1, 20 GB / 18 GiB Solaris /home 84812656 123881957 39069302 UFS1, 20 GB / 18 GiB Solaris /home 84824552 123893853 39069302 UFS1, 20 GB / 18 GiB Solaris /home 84824664 123893965 39069302 UFS1, 20 GB / 18 GiB Solaris /home 84847528 123916829 39069302 UFS1, 20 GB / 18 GiB Solaris /home 84847640 123916941 39069302 UFS1, 20 GB / 18 GiB Solaris /home 84886840 123956141 39069302 UFS1, 20 GB / 18 GiB Solaris /home 84886952 123956253 39069302 UFS1, 20 GB / 18 GiB Solaris /home 84945488 124014789 39069302 UFS1, 20 GB / 18 GiB Solaris /home 84945600 124014901 39069302 UFS1, 20 GB / 18 GiB Solaris /home 84957992 124027293 39069302 UFS1, 20 GB / 18 GiB Solaris /home 84958104 124027405 39069302 UFS1, 20 GB / 18 GiB Solaris /home 84962240 124031541 39069302 UFS1, 20 GB / 18 GiB Solaris /home 84962352 124031653 39069302 UFS1, 20 GB / 18 GiB Solaris /home 84977168 124046469 39069302 UFS1, 20 GB / 18 GiB Solaris /home 84977280 124046581 39069302 UFS1, 20 GB / 18 GiB MS Data 174395467 178483851 4088385 ..... snip (it keeps going on for quite a while)

    Read the article

  • How to Tell If Your Computer is Overheating and What to Do About It

    - by Chris Hoffman
    Heat is a computer’s enemy. Computers are designed with heat dispersion and ventilation in mind so they don’t overheat. If too much heat builds up, your computer may become unstable or suddenly shut down. The CPU and graphics card produce much more heat when running demanding applications. If there’s a problem with your computer’s cooling system, an excess of heat could even physically damage its components. Is Your Computer Overheating? When using a typical computer in a typical way, you shouldn’t have to worry about overheating at all. However, if you’re encountering system instability issues like abrupt shut downs, blue screens, and freezes — especially while doing something demanding like playing PC games or encoding video — your computer may be overheating. This can happen for several reasons. Your computer’s case may be full of dust, a fan may have failed, something may be blocking your computer’s vents, or you may have a compact laptop that was never designed to run at maximum performance for hours on end. Monitoring Your Computer’s Temperature First, bear in mind that different CPUs and GPUs (graphics cards) have different optimal temperature ranges. Before getting too worried about a temperature, be sure to check your computer’s documentation — or its CPU or graphics card specifications — and ensure you know the temperature ranges your hardware can handle. You can monitor your computer’s temperatures in a variety of different ways. First, you may have a way to monitor temperature that is already built into your system. You can often view temperature values in your computer’s BIOS or UEFI settings screen. This allows you to quickly see your computer’s temperature if Windows freezes or blue screens on you — just boot the computer, enter the BIOS or UEFI screen, and check the temperatures displayed there. Note that not all BIOSes or UEFI screens will display this information, but it is very common. There are also programs that will display your computer’s temperature. Such programs just read the sensors inside your computer and show you the temperature value they report, so there are a wide variety of tools you can use for this, from the simple Speccy system information utility to an advanced tool like SpeedFan. HWMonitor also offer this feature, displaying a wide variety of sensor information. Be sure to look at your CPU and graphics card temperatures. You can also find other temperatures, such as the temperature of your hard drive, but these components will generally only overheat if it becomes extremely hot in the computer’s case. They shouldn’t generate too much heat on their own. If you think your computer may be overheating, don’t just glance as these sensors once and ignore them. Do something demanding with your computer, such as running a CPU burn-in test with Prime 95, playing a PC game, or running a graphical benchmark. Monitor the computer’s temperature while you do this, even checking a few hours later — does any component overheat after you push it hard for a while? Preventing Your Computer From Overheating If your computer is overheating, here are some things you can do about it: Dust Out Your Computer’s Case: Dust accumulates in desktop PC cases and even laptops over time, clogging fans and blocking air flow. This dust can cause ventilation problems, trapping heat and preventing your PC from cooling itself properly. Be sure to clean your computer’s case occasionally to prevent dust build-up. Unfortunately, it’s often more difficult to dust out overheating laptops. Ensure Proper Ventilation: Put the computer in a location where it can properly ventilate itself. If it’s a desktop, don’t push the case up against a wall so that the computer’s vents become blocked or leave it near a radiator or heating vent. If it’s a laptop, be careful to not block its air vents, particularly when doing something demanding. For example, putting a laptop down on a mattress, allowing it to sink in, and leaving it there can lead to overheating — especially if the laptop is doing something demanding and generating heat it can’t get rid of. Check if Fans Are Running: If you’re not sure why your computer started overheating, open its case and check that all the fans are running. It’s possible that a CPU, graphics card, or case fan failed or became unplugged, reducing air flow. Tune Up Heat Sinks: If your CPU is overheating, its heat sink may not be seated correctly or its thermal paste may be old. You may need to remove the heat sink and re-apply new thermal paste before reseating the heat sink properly. This tip applies more to tweakers, overclockers, and people who build their own PCs, especially if they may have made a mistake when originally applying the thermal paste. This is often much more difficult when it comes to laptops, which generally aren’t designed to be user-serviceable. That can lead to trouble if the laptop becomes filled with dust and needs to be cleaned out, especially if the laptop was never designed to be opened by users at all. Consult our guide to diagnosing and fixing an overheating laptop for help with cooling down a hot laptop. Overheating is a definite danger when overclocking your CPU or graphics card. Overclocking will cause your components to run hotter, and the additional heat will cause problems unless you can properly cool your components. If you’ve overclocked your hardware and it has started to overheat — well, throttle back the overclock! Image Credit: Vinni Malek on Flickr     

    Read the article

  • Silverlight Cream Monday WP7 App Review # 1

    - by Dave Campbell
    I'm going to try something here... if it seems useful, I'll continue, if it doesn't, I'll stop... so give me feedback! There are *lots* of Apps in the WP7 Marketplace, and heaven help me, but the Marketplace sucks for finding stuff. I won't rehash what's already been said in the blogs, but I agree with one and all. I went out last Saturday to find 2 apps that I knew were released, and couldn't do so on my device. Even in the Zune app, it took quite a while to find them... ok, I'll back off a bit, because I just found out I can do 'Search' now if I know the name... I didn't think that was working before. So my thought is on Monday (like today), I will post a review of 5 apps/games I either use or have played with on my device. These are strictly my opinions, you understand, but hey... it's better than a poke in the eye with an iPhone! A few disclaimers:     Feel free to write me about your app and tell me about it. While it would be very cool to receive a whole bunch of xap files to review, at this point, for technical reasons, I'm unable to side-load my device. Since I plan on only doing this one day a week, and only 5, I may never get caught up, so if you send me some info, be patient. Re: games ... remember I'm old... I'm from the era of Colossal Cave and Zork. Duke-Nukem 2D and Captain Comic were awesome. I don't own an XBOX or any other game system, so take game reviews from my perspective -- who knows, it may be refreshing :) I won't pay for an app or game just to try it. If you expect me to test-drive your app, it's going to have to have a Free Trial. In this Issue:   Jingo! is the first app I bought, just to see what the experience was like. It's very much like a game we used to play in school in the Army in 1971 on paper we passed around. Sort of a cross between hangman and Mastermind, you try to figure out the hidden word in 5 tries. You get really good at 5-letter words after a while. I like this because you have to think, and you're not pressured by a clock Jingo! is by James Furdell and is $1.99 I reviewed René Schulte's Pictures Lab a while back, and have not changed my mind. This is an excellent app for playing with any photo on your device... one you've just taken, one you've synced from your PC, or one you've saved from email. I like this because you can get some cool effects for your photos, and it just works. Pictures Lab is by Schulte Software Development and is $1.99 Since I work as a consultant, and from home, I wanted something I could track my time with. I've test-driven all the contenders I could find so far on the phone, and so far I like ONTRACK! the best. If asked, I have some suggestions, but it's probably just the way I work or think. What I do like is I can tap a project to start/stop/restart a counter, and at the end of the day it shows me how much time I've been working. If there's a way to make an adjustment in case you forget to tap the counter, I don't know how to do it, and that's my biggest complaint. I like this because you can get a daily readout which you can also email as a spreadsheet. The daily results display is very good. ONTRACK! is by Qmino and is $2.99 Remember Item 4 above... I've been playing guitar for 48 years... obviously since before the invention of 'tuners', so I'm not as dependent upon these as some folks are. I've tried some in the past and have always felt I can do just as good by ear (I have perfect relative pitch). So, I gave this app by András Velvárt a dance just to see how it works, and it is surprisingly good. If you're used to one of the stage tuners this may take a little getting used to, but it does the job. The difference with this one is there is no real 'null' point inside which you can think your guitar is in tune. The soundwave stays visible on the device, and if it's moving to the right, your string is flat, if it's moving to the left, your string is sharp. Getting it exact might be tricky, but it is exact! If you need to rely on a tuner, this is a good choice in my opinion, exactly because of the sensitivity.. tune up with this and you're dead-on. Guitar Tuner is by Kinabalu Innovation Limited and is $0.99 Popper 2 is the WP7 version of a wildly popular game by Bill Reiss named Dr. Popper. You can get a trial, or you can now get a free lite version of the game. Popper 2 is a fast-paced bubble breaker game. I find it something fun to play when I just want to buzz out, but maybe the best review is that my daughter didn't want to give my phone back when I showed it to her, and always wants to grab my phone to play 'that game'. A fun distraction with great graphics and a great price Popper 2 is by Blue Rose Systems, LLC and is $1.29 Let me know what you think of the idea of doing reviews, or the layout/whatever, and Stay in the 'Light!   Twitter SilverlightNews | Twitter WynApse | WynApse.com | Tagged Posts | SilverlightCream Join me @ SilverlightCream | Phoenix Silverlight User Group Technorati Tags: Silverlight    Silverlight 3    Silverlight 4    Windows Phone MIX10

    Read the article

  • H1 Visa interview tips–What you must know before attending the interview?

    - by Gopinath
    USA’s H1 visa allows highly qualified professionals from other countries to work in America. Many IT professionals in India aspire to go to USA on H1 and work for their clients. Recently I had a chance to study H1 visa process to help one of my friends and I would like to share what I learned. With the assumption that your H1 petition is approved and you got an interview scheduled at US Embassy for your visa stamping, here are tips you must know before attending the interview Dress Code – Formals Say no to casuals or any fancy dress when you attend the interview. It’s not a party or friends home you are visiting. Consider H1 Visa interview as your job interview and dress up in formals. There is no option B for your, you must be in formals. A plain formal shirt with a matching pant is suggested for men. Tie and Suit would not be required, but if you are a professional at management level you can consider wearing suit. Women can wear either formal Salwar or formal pant-shirt. Avoid heavy jewellery, wear what is must as per your tradition or culture. Body Language -  Smile on your face Your body language reflects what you are and what’s going on in your mind. Don’t be nervous or restless, be relaxed and wear a beautiful smile on your face. A smile is a curve that sets everything straight. When you are called for the interview, greet the interviewer with a beautiful smile. Say Good Morning/Afternoon/Evening depending on time you are visiting them. Whenever appropriate say Thank You. Generally American professionals are very friendly people and they reciprocate for your greetings. Make sure that you make them comfortable to start the interview. Carry original documents in a separate folder I don’t want to talk much about the documents that are required for your H1B interview as it’s big subject on it’s own and it requires a separate post. I assume that your consultant or employer helped you in gathering all the required documents like – petition, DS 160 forms, education & job related documents, resume, interview call letters, client letters, etc. For all the documents you are going to submit at the interview make sure that you have originals in a separate folder.  If required interviewer may ask you show the originals of any of the document you submitted for visa processing. Don’t mix the original documents with the documents you need to submit for interview. Have a separate folder for them. For those who are going to stamping along with their spouse and children, they need to carry few extra original documents like – marriage certificate, marriage photos(30 numbers)/album, birth certificates, passports, education and profession related certificates of the spouse and children. Know your role & responsibilities The interviewer will ask you questions on your roles and responsibilities at client location. Be clear what is your day to day tasks at client place and prepared to face detailed questions on the same. When asked explain clearly and also make sure what you say is inline with what is mentioned in your petition and client invitation letter. At times they may ask you questions specific to the project/technology you are going to work. So doing some homework in this area will help you easily answer the questions. Failing to answer basic questions on your role & responsibilities may result in rejection. You work for your Employer at Client location but NOT FOR CLIENT One of the important things to keep in mind that you work for your employer and you are being deputed to client location on a work visa.  Your employer is going to be solely responsible for your salary, work, promotion, pay hikes or what so ever during your stay at USA. Your client will not be responsible for anything. Lets say you are employed with Company X in India and they are applying for H1B to work at your client(ex: Microsoft) in USA, you must keep in my mind that Microsoft is not your employer. Microsoft will not pay your salaries or responsible for any employment related activities. Company X will be solely responsible for all your employer related activities. If you don’t get this correctly and say to Visa interviewer that your client is responsible, then you may get into troubles. Know your client It’s always good to know the clients with whom you are going to work in USA and their business. If your client is a well know organisation then you may not get many questions from interviewer else you need to be well prepared to provide details like – nature of business, location, size of the organisation, etc.  Get to know the basic details about your client and be confident while providing those details to the interviewer. Also make sure that you never talk about any confidential details of your client projects and business. Revealing confidential details of your client may land your job itself in soup. Make sure that your spouse is also in sync with you If you’ve applied a H4 visa for your spouse along with your H1, make sure that spouse is in sync with you. Your spouse also should know the basic details of your job, your employer, client and location where you will be travelling. Your spouse should also be prepared to answers questions related to marriage, their profession(if working), kids, education, etc. Interviewers will try to asses your spouse communication skills, whereabouts while staying in USA and would they prefer to work USA or not. On H4, which is a dependent visa, your spouse is not allowed to work in USA and at any point your spouse should not show the intentions to search for work in USA. Less luggage more comfort You would have definitely heard that there are lot of restrictions on what you can carry along with you to an US Embassy while attending the interview. To be frank it’s not good to say there are many restrictions, but there are a hell a lot of restrictions. There are unbelievable restrictions and it’s for the safety of everyone. You are not allowed to carry mobile phones, CD/DVDs, USBs, bank cards, cameras, cosmetics, food(except baby food), water, wallets, backpacks, sealed covers, etc. Trust me most of the things we carry with us regularly every day are not allowed inside. As there are 100s of restrictions, it would be easier if you understand what you can carry along with you and just carry them alone. Ask your employer/consultant to provide you a checklist of items that you can carry. Most what you would require are H1B related documents provided by the employer/consultant Photographs All original documents supporting your H1B Passports Some cash for your travel expenses (avoid coins) Any important phone number / details written in a paper(like your cab driver number, etc.) If you carry restricted stuff then you will be stopped at security checks, you have to find people who can safely keep all the restricted items. Due to heavy restrictions in and around the US Embassy you will not find any  place to keep your luggage. So just carry the bare minimum things required so that you feel more comfortable. Useful Links THE U.S. NON IMMIGRANT VISA APPLICATION PROCESS U.S VISA SECURITY REGULATIONS GENERAL FAQS Hope this information is helpful to you and best of luck for your interview. Creative commons Image credit: Flickr/ alexfrance, vinothchandar. hughelectronic, architratan, striatic

    Read the article

  • Spacewalk 2.0 provided to manage Oracle Linux systems

    - by wcoekaer
    Oracle Linux customers have a few options to manage and provision their servers. We provide a license to use Oracle Enterprise Manager's Linux OS management, monitoring and provisioning features without additional cost for every server that has an Oracle Linux support subscription. So there is no additional pack to license and no additional per server cost, it's all included in our Basic, Premier and Systems support subscriptions. The nice thing with Oracle Enterprise Manager is that you end up with a single management product that can manage all aspects of your software stack. You have complete insight into the applications running, you have roles and responsibilities, you have third party connectors for storage or other products and it makes it very easy and convenient to correlate data and events when something happens. If you use Oracle VM as well, you end up with a complete cloud portal with selfservice, chargeback, etc... Another, much simpler option, is just using yum. It is very easy to take a server and create directories and expose these through apache as repositories. You can have a simple yum config on each server pointing to a few specific repositories. It requires some manual effort in terms of creating directories, downloading packages and creating local repo files but it's easy to do and for many people a preferred solution. There are also a good number of customers that just connect their servers directly to ULN or to our free update server public-yum. Just to re-iterate, our public-yum servers have all the errata and updates available for free. Now we added another option. Many of our customers have switched from a competing Linux vendor and they had familiarity with their management tools. Switching to Oracle for support is very easy since we don't require changes to the installed servers but we also want to make sure there is a very easy and almost transparent switch for the management tools as well. While Oracle Enterprise Manager is our preferred way of managing systems, we now are offering Spacewalk 2.0 to our customers. The community project can be found here. We have made a few changes to ensure easy and complete support for Oracle Linux, tested it with public-yum, etc.. You can find the rpms in our public-yum repos at http://public-yum.oracle.com/repo/OracleLinux/OL6/. There are repositories for spacewalk server and then for each version (OL5,OL6) and architecture (x86 and x86-64) we have the client repositories as well. Spacewalk itself is only made available for OL6 x86-64. Documentation can be found here. I set it up myself and here are some quick steps on how you can get going in just a matter of minutes: Spacewalk Server Installation : 1) Installing an Oracle Database Use an existing Oracle Database or install a new Oracle Database (Standard or Enterprise Edition) [at this time use 11g, we will add support for 12c in the near future]. This database can be installed on the spacewalk server or on a separate remote server. While Oracle XE might work to create a small sample POC, we do not support the use of Oracle XE, spacewalk repositories can become large and create a significant database workload. Customers can use their existing database licenses, they can download the database with a trial licence from http://edelivery.oracle.com or Oracle Linux subscribers (customers) will be allowed to use the Oracle Database as a spacewalk repository as part of their Oracle Linux subscription at no additional cost. |NOTE : spacewalk requires the database to be configured with the UTF8 characterset. |Installation will fail if your database does not use UTF8. |To verify if your database is configured correctly, run the following command in sqlplus: | |select value from nls_database_parameters where parameter='NLS_CHARACTERSET'; |This should return 'AL32UTF8' 2) Configure the database schema for spacewalk Ideally, create a tablespace in the database to hold the spacewalk schema tables/data; create tablespace spacewalk datafile '/u01/app/oracle/oradata/orcl/spacewalk.dbf' size 10G autoextend on; Create the database user spacewalk (or use some other schema name) in sqlplus. example : create user spacewalk identified by spacewalk; grant connect, resource to spacewalk; grant create table, create trigger, create synonym, create view, alter session to spacewalk; grant unlimited tablespace to spacewalk; alter user spacewalk default tablespace spacewalk; 4) Spacewalk installation and configuration Spacewalk server requires an Oracle Linux 6 x86-64 system. Clients can be Oracle Linux 5 or 6, both 32- and 64bit. The server is only supported on OL6/64bit. The easiest way to get started is to do a 'Minimal' install of Oracle Linux on a server and configure the yum repository to include the spacewalk repo from public-yum. Once you have a system with a minimal install, modify your yum repo to include the spacewalk repo. Example : edit /etc/yum.repos.d/public-yum-ol.repo and add the following lines at the end of the file : [spacewalk] name=spacewalk baseurl=http://public-yum.oracle.com/repo/OracleLinux/OL6/spacewalk20/server/$basearch/ gpgkey=http://public-yum.oracle.com/RPM-GPG-KEY-oracle-ol6 gpgcheck=1 enabled=1 Install the following pre-requisite packages on your spacewalk server : oracle-instantclient11.2-basic-11.2.0.3.0-1.x86_64 oracle-instantclient11.2-sqlplus-11.2.0.3.0-1.x86_64 rpm -ivh oracle-instantclient11.2-basic-11.2.0.3.0-1.x86_64 rpm -ivh oracle-instantclient11.2-sqlplus-11.2.0.3.0-1.x86_64 The above RPMs can be found on the Oracle Technology Network website : http://www.oracle.com/technetwork/topics/linuxx86-64soft-092277.html As the root user, configure the library path to include the Oracle Instant Client libraries : cd /etc/ld.so.conf.d echo /usr/lib/oracle/11.2/client64/lib oracle-instantclient11.2.conf ldconfig Install spacewalk : # yum install spacewalk-oracle The above yum command should download and install all required packages to run spacewalk on your local server. | NOTE : if you did a full, desktop or workstation installation, | you have to remove the JTA package | BEFORE installing spacewalk-oracle (rpm -e --nodeps jta) Once the installation completes, simply run the spacewalk configuration tool and you are all set. (make sure to run the command with the 2 arguments) spacewalk-setup --disconnected --external-db Answer the questions during the setup, ensure you provide the current database user (example : spacewalk) and password (example : spacewalk) and database server hostname (the standard hostname of the server on which you have deployed the Oracle database) At the end of the setup script, your spacewalk server should be fully configured and you can log into the web portal. Use your favorite browser to connect to the website : http://[spacewalkserverhostname] The very first action will be to create the main admin account.

    Read the article

  • How to Recover From a Virus Infection: 3 Things You Need to Do

    - by Chris Hoffman
    If your computer becomes infected with a virus or another piece of malware, removing the malware from your computer is only the first step. There’s more you need to do to ensure you’re secure. Note that not every antivirus alert is an actual infection. If your antivirus program catches a virus before it ever gets a chance to run on your computer, you’re safe. If it catches the malware later, you have a bigger problem. Change Your Passwords You’ve probably used your computer to log into your email, online banking websites, and other important accounts. Assuming you had malware on your computer, the malware could have logged your passwords and uploaded them to a malicious third party. With just your email account, the third party could reset your passwords on other websites and gain access to almost any of your online accounts. To prevent this, you’ll want to change the passwords for your important accounts — email, online banking, and whatever other important accounts you’ve logged into from the infected computer. You should probably use another computer that you know is clean to change the passwords, just to be safe. When changing your passwords, consider using a password manager to keep track of strong, unique passwords and two-factor authentication to prevent people from logging into your important accounts even if they know your password. This will help protect you in the future. Ensure the Malware Is Actually Removed Once malware gets access to your computer and starts running, it has the ability to do many more nasty things to your computer. For example, some malware may install rootkit software and attempt to hide itself from the system. Many types of Trojans also “open the floodgates” after they’re running, downloading many different types of malware from malicious web servers to the local system. In other words, if your computer was infected, you’ll want to take extra precautions. You shouldn’t assume it’s clean just because your antivirus removed what it found. It’s probably a good idea to scan your computer with multiple antivirus products to ensure maximum detection. You may also want to run a bootable antivirus program, which runs outside of Windows. Such bootable antivirus programs will be able to detect rootkits that hide themselves from Windows and even the software running within Windows. avast! offers the ability to quickly create a bootable CD or USB drive for scanning, as do many other antivirus programs. You may also want to reinstall Windows (or use the Refresh feature on Windows 8) to get your computer back to a clean state. This is more time-consuming, especially if you don’t have good backups and can’t get back up and running quickly, but this is the only way you can have 100% confidence that your Windows system isn’t infected. It’s all a matter of how paranoid you want to be. Figure Out How the Malware Arrived If your computer became infected, the malware must have arrived somehow. You’ll want to examine your computer’s security and your habits to prevent more malware from slipping through in the same way. Windows is complex. For example, there are over 50 different types of potentially dangerous file extensions that can contain malware to keep track of. We’ve tried to cover many of the most important security practices you should be following, but here are some of the more important questions to ask: Are you using an antivirus? – If you don’t have an antivirus installed, you should. If you have Microsoft Security Essentials (known as Windows Defender on Windows 8), you may want to switch to a different antivirus like the free version of avast!. Microsoft’s antivirus product has been doing very poorly in tests. Do you have Java installed? – Java is a huge source of security problems. The majority of computers on the Internet have an out-of-date, vulnerable version of Java installed, which would allow malicious websites to install malware on your computer. If you have Java installed, uninstall it. If you actually need Java for something (like Minecraft), at least disable the Java browser plugin. If you’re not sure whether you need Java, you probably don’t. Are any browser plugins out-of-date? – Visit Mozilla’s Plugin Check website (yes, it also works in other browsers, not just Firefox) and see if you have any critically vulnerable plugins installed. If you do, ensure you update them — or uninstall them. You probably don’t need older plugins like QuickTime or RealPlayer installed on your computer, although Flash is still widely used. Are your web browser and operating system set to automatically update? – You should be installing updates for Windows via Windows Update when they appear. Modern web browsers are set to automatically update, so they should be fine — unless you went out of your way to disable automatic updates. Using out-of-date web browsers and Windows versions is dangerous. Are you being careful about what you run? – Watch out when downloading software to ensure you don’t accidentally click sketchy advertisements and download harmful software. Avoid pirated software that may be full of malware. Don’t run programs from email attachments. Be careful about what you run and where you get it from in general. If you can’t figure out how the malware arrived because everything looks okay, there’s not much more you can do. Just try to follow proper security practices. You may also want to keep an extra-close eye on your credit card statement for a while if you did any online-shopping recently. As so much malware is now related to organized crime, credit card numbers are a popular target.     

    Read the article

< Previous Page | 548 549 550 551 552 553 554 555 556 557 558 559  | Next Page >