Search Results

Search found 30909 results on 1237 pages for 'app switching'.

Page 56/1237 | < Previous Page | 52 53 54 55 56 57 58 59 60 61 62 63  | Next Page >

  • Replicate GAE Datastore On A Server LAN in Java

    - by Franz Noel
    There may be instances wherein one Company Client may not have internet connection on their vicinity. Either their Internet Service Provider currently experience a down time or there are some other problems involving the network, but not their LAN. GAE seems to be needing a connection at all times in the internet. I only need GAE Datastore. I'm thinking about a different application. Creating a Java Swing Client, for instance, and connecting to the Office Server via HRD of GAE Datastore. When I tried to check on the solutions for Java, it does not say anything about uploading all data and I do not need the App. I just need the GAE Datastore. In Java GAE, only indexes can be able to be manipulated. So, is there any tricks/ideas that you can use HRD with GAE Datastore on Java with an Internal Office Server combined? This way, it may provide service even during network down times. (Can somebody create me a tag of gae-datastore, please.)

    Read the article

  • How to mange big amount users at server side?

    - by Rami
    I built a social android application in which users can see other users around them by gps location. at the beginning thing went well as i had low number of users, But now that I have increasing number of users (about 1500 +100 every day) I revealed a major problem in my design. In my Google App Engine servlet I have static HashMap that holding all the users profiles objects, currenty 1500 and this number will increase as more users register. Why I'm doing it Every user that requesting for the users around him compares his gps with other users and check if they are in his 10km radius, this happens every 5 min on average. That is why I can't get the users from db every time because GAE read/write operation quota will tare me apart. The problem with this desgin is As the number of users increased the Hashmap turns to null every 4-6 hours, I thing that this time is getting shorten but I'm not sure. I'm fixing this by reloading the users from the db every time I detect that it became null, But this causes DOS to my users for 30 sec, So I'm looking for better solution. I'm guessing that it happens because the size of the hashmap, Am I right? I have been advised to use spatial database, but that mean that I can't work with GAE any more and that mean that I need to build my big server all over again and lose my existing DB. Is there something I can do with the existing tools? Thanks.

    Read the article

  • How to manage many mobile device users at server side?

    - by Rami
    I built a social Android application in which users can see other users around them by GPS location. At the beginning thing went well as I had low number of users, but now that I have increasing number of users (about 1500 +100 every day) it has revealed a major problem in my design. In my Google App Engine servlet I have static HashMap that holds all the users profiles objects, currently 1500 and this number will increase as more users register. Why I'm doing it? Every user that requests for the users around him compares his GPS with other users and checks if they are in his 10km radius. This happens every five minutes on average. Consequently, I can't get the users from db every time because GAE read/write operation quota will tear me apart. The problem with this design is? As the number of users increases, the Hashmap turns to null every 4-6 hours, I think that this time is getting shorter, but I'm not sure. I'm fixing this by reloading the users from the db every time I detect that it becomes null, but this causes DOS to my users for 30 sec, so I'm looking for better solution. I'm guessing that it happens because the size of the hashmap. Am I right? I have been advised to use a spatial database, but that means that I can't work with GAE any more and it means that I need to build my big server all over again and lose my existing DB. Is there something I can do with the existing tools? Thanks.

    Read the article

  • Data Synchronization in mobile apps - multiple devices, multiple users

    - by ProgrammerNewbie
    I'm looking into building my first mobile app. One of the core features of the application is that multiple devices/users will have access to the same data -- and all of them will have CRUD rights. I believe the architecture should involve a central server where all the data is stored. The devices will use an API to interact with the server to perform its data operations (e.g. adding a record, editing a record, deleting a record). I imagine a scenario where synchronizing the data will become a problem. Assume the application should work when it is not connected to the Internet, and thus cannot communicate with this central server. So: User A is offline and edits record #100 User B is offline and edits record #100 User C is offline and deletes record #100 User C goes online (presumably, record #100 should get deleted on the server) User A and B goes online, but the records they edited no longer exist All sorts of scenarios similar to the above can come up. How is this generally handled? I plan to use MySQL, but am wondering if it's not appropriate for such a problem.

    Read the article

  • On Developing Web Services with Global State

    - by user74418
    I'm new to web programming. I'm more experienced and comfortable with client-side code. Recently, I've been dabbling in web programming through Python's Google App Engine. I ran into some difficulty while trying to write some simple apps for the purposes of learning, mainly involving how to maintain some kind of consistent universally-accessible state for the application. I tried to write a simple queueing management system, the kind you would expect to be used in a small clinic, or at a cafeteria. Typically, this is done with hardware. You take a number from a ticketing machine, and when your number is displayed or called you approach the counter for service. Alternatively, you could be given a small pager, which will beep or vibrate when it is your turn to receive service. The former is somewhat better in that you have an idea of how many people are still ahead of you in the queue. In this situation, the global state is the last number in queue, which needs to be updated whenever a request is made to the server. I'm not sure how to best to store and maintain this value in a GAE context. The solution I thought of was to keep the value in the Datastore, attempt to query it during a ticket request, update the value, and then re-store it with put. My problem is that I haven't figured out how to lock the resource so that other requests do not check the value while it is in the middle of being updated. I am concerned that I may end up ticket requests that have the same queue number. Also, the whole solution feels awkward to me. I was wondering if there was a more natural way to accomplish this without having to go through the Datastore. Can anyone with more experience in this domain provide some advice on how to approach the design of the above application?

    Read the article

  • HP ProCurve & Cisco switches interoperability

    - by Kamil Z
    I have a couple of questions regarding Cisco and HP ProCurve interoperability. Here's a link to pdf with my network topology. Can someone help me with basic VLAN configuration in such topology? Below there are some details of my configuration: # m_management_2 interface FastEthernet0/43 switchport access vlan 250 switchport mode access spanning-tree port-priority 32 spanning-tree cost 100 # MTA2-swmgmt1 vlan 1 name "DEFAULT_VLAN" untagged 1-48 ip address 10.10.249.190 255.255.255.128 exit # MTA2-swtr1 vlan 1 name "DEFAULT_VLAN" untagged 1-14,16-48 no ip address no untagged 15 exit vlan 100 name "MTA Mgmt" untagged 15 ip address 10.10.249.188 255.255.255.128 exit # MTA2-swtr2 vlan 1 name "DEFAULT_VLAN" untagged 1-14,16-48 no ip address no untagged 15 exit vlan 100 name "MTA Mgmt" untagged 15 ip address 10.10.249.189 255.255.255.128 exit I don't post MTA2-bcsw[12] configuration, because I wasn's successfull in this one yet. Every time I configure VLANs on MTA2-bcsw[12] Fa0/24 interface on m_management_2 goes down bacause of receiving tagged BPDUs on access port (there are no VLANs configured on MTA2-swmgmt1 because of fact that only 250 VLAN is allowed in this switch. Is it correct?). Can someone provide me some basic configuration for this topology? Second thing I want to ask is concept of connection from MTA2-swmgmt1 to MTA2-swtr[12] HP switches for the sake of management. How to configure such ports on HP switches (managed switch and manager switch). Is my actual configuration correct?

    Read the article

  • ESXI 5.1 - Unable to trunk to cisco switch

    - by Lance
    I have configured my esxi host vSwitch1 to use the secondary NIC on my VMware host. On vSwitch1 configuration I have set the VLAN to 4095 which specifies to allow all VLANs. If my cisco switch port configuration is set to an access port my server can ping the vlan interface on the switch. If my cisco switch port configuration is set to a trunk, whilst it stays UP UP and CDP information is available, I lose my ping from VMware VM server to the local vlan interface on the switch and I lose any server connectivity to my network. Switch NIC teaming policy to Route based on originating virtual port ID Configuration based on: http://kb.vmware.com/selfservice/microsites/search.do?language=en_US&cmd=displayKC&externalId=1006628 interface GigabitEthernet0/42 description Host Port switchport trunk encapsulation dot1q switchport trunk allowed vlan 18,220 switchport mode trunk switchport nonegotiate spanning-tree portfast trunk end Output from ESXI CLI esxcfg-vswitch -l: ~ # esxcfg-vswitch -l Switch Name Num Ports Used Ports Configured Ports MTU Uplinks vSwitch0 128 5 128 1500 vmnic0 PortGroup Name VLAN ID Used Ports Uplinks VM Network 4095 1 vmnic0 Management Network 4095 1 vmnic0 Switch Name Num Ports Used Ports Configured Ports MTU Uplinks vSwitch1 128 4 128 1500 vmnic1 PortGroup Name VLAN ID Used Ports Uplinks VM Network 2 4095 1 vmnic1 Any tips welcome!!!

    Read the article

  • Should I remove all unmanged switches from my network?

    - by IMAbev
    I have a office network with approx 150 devices (computers/printers/ip phones). Almost all of the end point devices have straight run Cat5e from my Hp switches directly to the device. IP phones for each end user sit between the hp switch and computer. (hp switch - in to phone out of phone in to computer) While I have gotten rid of most of them, I still have a couple linksys unmanaged switches that split off to 2 or more devices. I have heard various reasons for removing these switches but not entirely sure if it actually degrades the network. I agree that eliminating these switches certainly cleans up the network from a management standpoint. Are these unmanaged switches bad for my network? Is there a clear advantage to having 'home run' cable runs to each of my end point devices?

    Read the article

  • Cisco vlan entry missing in vlan.dat, but appears in running-config

    - by nLinked
    One of our vlan's (ID: 104) stopped working suddenly and computers on that vlan failed when trying to obtain a dhcp ip address. On the Cisco switch if we do show vlan, this command is supposed to shows the vlans in the vlan.dat file. We notice it has every other vlan except the one that is now missing. If we show the running-config or even the startup config, they DO show the missing vlan (as if everything is fine), but that vlan doesn't take effect. We tried deleting the "missing" vlan using clear vlan 104, but it says No subinterface configured for vLAN Identifier 104, so it's already missing. Recreating the vlan, saving and rebooting still doesn't add it into the vlan.dat or make the vlan work. The switch is in vtp server mode. Our startup config is here: http://pastebin.com/RHxxTG5p Any ideas appreciated.

    Read the article

  • Port binding conflicts with "switch user" on Windows 7

    - by C-dizzle
    We are using the switch user function within Windows 7 under an active directory network. We have one application in particular that gives us an error: Only one usage of each socket address (protocol/network address/port) is normally permitted. bind Port 10001 Are there any other ports that can only be used at one time that might have an adverse effect on the other user? We try to mentor our users to use the log off function instead of switch user, but that doesn't always happen. As an alternative, is it possible to disable the 'switch user' button on our machines?

    Read the article

  • Turning down the sound on a switched off user

    - by soandos
    If one switches users (i.e. user one switches off, and then another users logs in) and there is sound playing on the first user, that sound will continue to play for the second user. If the second user has admin rights, they can guess what program is causing the sound and then kill it, but that is very clumsy, and far more than what "needs" to be done. When I open the mixer, it just shows that sound is playing. How can I stop it?

    Read the article

  • Moving MODx Files to Other MODx Website

    - by Austin
    I have one website with modx installed to www.website.com/modx/ --- Keep in mind there are other Websites In Progress on this storage server. My issue is that I'm moving all this: templates, template variables, chunks, snippets, etc to another server that already has modx installed in it. My first instinct is to go to phpMyAdmin and export the sql file and import them to the new website's server. However, an error occurred when I attempted to do this. It had found many duplicates in fields that were associated a PK (due to it being the same website just a redesign). I don't have to go and dump the table of the oldsite and then upload the new sql file do i? Please advise.

    Read the article

  • Autonegotiate errors between HP and Cisco hardware?

    - by Satanicpuppy
    This is a bit of a specific extension to this question. I've got two ASA's that feed into a Procurve switch, and then into an IPS. All is well except that the procurve absolutely refuses to autonegotiate with the ASA's...The asa's run 100full, and the procurve autonegotiates to 100half. It does it for both ASA's, so it's probably not a failure on one of them, and everything works fine if I force the procurve to 100full. Has anyone else seen this issue? I've been buying more HP hardware, but I'm not keen on getting equipment that's not going to play nice with my Cisco backbone.

    Read the article

  • Hubs/switches taking out switches?

    - by Bart Silverstrim
    Here's the issue...we have a network with a lot of Cisco switches. Someone plugged in a hub on the network, and then we started seeing "weird" behavior; errors in communication between clients and servers, or network timeouts, dropping network connections, etc. It seemed that somehow that hub (or SOHO switch) was particularly freaking out our Cisco 3700 series switches. Disconnect that hub or netgear-type SOHO switch and things settled down again. We're in the process of trying to get a centralized logging server for SNMP and management, etc., to see if we can trap errors or narrow down when someone does this sort of thing without our knowledge because things seem to work, for the most part, without issue, we just get freaky oddball incidents on particular switches that don't seem to have any explanation until we find out someone decided to take matters into their own hands to expand available ports in their room. Without getting into procedure changes or locking down ports or "in our organization they'd be fired" answers, can someone explain why adding a small switch or hub, not necessarily a SOHO router (even a dumb hub apparently caused the 3700's to freak out) sending DHCP request out, will cause issues? The boss said it's because the Cisco's are getting confused because that rogue hub/switch is bridging multiple MAC's/IP's into one port on the Cisco switches and they just choke on that, but I thought their routing tables should be able to handle multiple machines coming into the port. Anyone see that behavior before and have a clearer explanation of what's happening? I'd like to know for future troubleshooting and better understanding that just waving my hand and saying "you just can't".

    Read the article

  • Are there any statistics on the number of networks using Ethernet Jumbo frames?

    - by Russell Heilling
    I am often told by Sales Engineers and Product managers that a Layer 2 Ethernet service is not fit for purpose if the maximum supported frame size is in the 1518-1522 range (enough to support standard Ethernet frames or VLAN tagged frames). Or in other words: an MTU of 1500 is not enough (see this blog post for my definition of MTU and a short rant on how the term is often misused) I am never able to get any details from them on: a) What proportion of customers (Enterprise / SMB) require Jumbo frames b) What are typical expectations on frame size for Jumbos on WAN links? 1600, 2000, 9k, etc... I know that in Telco and Data Centre environments Jumbos are pretty common, but I am after some insight as to how common this is within Enterprise and SMB networks.

    Read the article

  • Disable of discrete/native graphics on MacBook Retina when using apps like VMware, VLC, etc

    - by badkitteh
    I got a MacBook Pro Retina a few months ago and I'm really happy with it. However, since I do a lot of work in different environments/OSes, I make heavy use of VMware to have them with me when I'm on the road. The MBPr has a great battery life - as long as integrated graphics are being used. Unfortunately as soon as I launch VMware, the MacBook switches to discrete graphics and battery life is effectively halved. I noticed that after installing gfxCardStatus, and now I'm wondering if there is a way to force the integrated graphics being used all of the time, so I can enjoy maximum battery life. Thanks.

    Read the article

  • Switch flooding when bonding interfaces in Linux

    - by John Philips
    +--------+ | Host A | +----+---+ | eth0 (AA:AA:AA:AA:AA:AA) | | +----+-----+ | Switch 1 | (layer2/3) +----+-----+ | +----+-----+ | Switch 2 | +----+-----+ | +----------+----------+ +-------------------------+ Switch 3 +-------------------------+ | +----+-----------+----+ | | | | | | | | | | eth0 (B0:B0:B0:B0:B0:B0) | | eth4 (B4:B4:B4:B4:B4:B4) | | +----+-----------+----+ | | | Host B | | | +----+-----------+----+ | | eth1 (B1:B1:B1:B1:B1:B1) | | eth5 (B5:B5:B5:B5:B5:B5) | | | | | | | | | +------------------------------+ +------------------------------+ Topology overview Host A has a single NIC. Host B has four NICs which are bonded using the balance-alb mode. Both hosts run RHEL 6.0, and both are on the same IPv4 subnet. Traffic analysis Host A is sending data to Host B using some SQL database application. Traffic from Host A to Host B: The source int/MAC is eth0/AA:AA:AA:AA:AA:AA, the destination int/MAC is eth5/B5:B5:B5:B5:B5:B5. Traffic from Host B to Host A: The source int/MAC is eth0/B0:B0:B0:B0:B0:B0, the destination int/MAC is eth0/AA:AA:AA:AA:AA:AA. Once the TCP connection has been established, Host B sends no further frames out eth5. The MAC address of eth5 expires from the bridge tables of both Switch 1 & Switch 2. Switch 1 continues to receive frames from Host A which are destined for B5:B5:B5:B5:B5:B5. Because Switch 1 and Switch 2 no longer have bridge table entries for B5:B5:B5:B5:B5:B5, they flood the frames out all ports on the same VLAN (except for the one it came in on, of course). Reproduce If you ping Host B from a workstation which is connected to either Switch 1 or 2, B5:B5:B5:B5:B5:B5 re-enters the bridge tables and the flooding stops. After five minutes (the default bridge table timeout), flooding resumes. Question It is clear that on Host B, frames arrive on eth5 and exit out eth0. This seems ok as that's what the Linux bonding algorithm is designed to do - balance incoming and outgoing traffic. But since the switch stops receiving frames with the source MAC of eth5, it gets timed out of the bridge table, resulting in flooding. Is this normal? Why aren't any more frames originating from eth5? Is it because there is simply no other traffic going on (the only connection is a single large data transfer from Host A)? I've researched this for a long time and haven't found an answer. Documentation states that no switch changes are necessary when using mode 6 of the Linux interface bonding (balance-alb). Is this behavior occurring because Host B doesn't send any further packets out of eth5, whereas in normal circumstances it's expected that it would? One solution is to setup a cron job which pings Host B to keep the bridge table entries from timing out, but that seems like a dirty hack.

    Read the article

  • servers connected to a poweredge 6248 receive traffic for their 'neighbours'

    - by Hannes
    In the network we have a few vlans but at the moment I was investigating vlan2 which carries the most traffic. When tcpdumping on the eth0.2 interface, I see a lot of packets arriving which are not addressed to, nor coming from the server. I checked this on several servers in the network and they all have the same issues. In short, our switches don't switch the traffic but threat it like they are a hub. Can you tell me what settings on the dell poweredge 6248 should prevent this behaviour?

    Read the article

  • Connecting office to data center via Metro-ethernet

    - by Eric
    I am installing a metro ethernet link from my office to my data center. The office will have a cisco 3750 with several vlans. The data center end will have a more complicated set up. The metro e from the office will connect to a 2960, which will have two other 2960s with a few vlans and a 2811 router connected to it for connectivity to our other environments and the internet. I am looking at implementing this by connecting the office 3750 and the data center 2960 with a dot1q trunk and doing all routing at the 2811. I will configure subinterfaces for gateways for each of the vlans on the 2811. I work for a small company and don't have much of a budget for an ideal architecture. I can post a simple diagram if needed for clarification. Is there anything I am missing here? I feel like I am forgetting something very basic and want to make sure I eliminate any boneheaded mistakes.

    Read the article

  • Have to run auto-negotiate between clients and switch - "old" switch works fine - "new" switch results in "port flapping"?

    - by ConfusedAboutSwitching
    I need some help understanding a problem we're having at work: We run Altiris/Deployment Solution and have to use auto-negotiate between client systems and our switches (Altiris apparently requires this for imaging, PXE boot and other functions). We have several areas with old wiring (Cat 3 & Cat 5) that have old 10/100 Cisco switches in them - and we can set these systems up to "auto/auto" (auto-negotiate on both the NIC and the switch port), and everything has been working fine. But - our networking crew changed out a couple of old switches for 10/100/1000 Cisco switches, and now - they are claiming that "auto/auto" won't work because the switches can't auto-negotiate the way the old 10/100 switches did - and that if we try to set the new gig switches to auto-negotiate, the switch port starts "port flapping", and shuts the port down. But - if we put the old switch back in - they work using "auto/auto" just fine - no port flapping. The networking crew is telling me that the problem is that we're putting "new switches" on "old wire", and that the old cabling can't/won't support the auto-negotiation with these new switches....??? There's something about this that doesn't make sense to me - can someone explain this to me? Or is our networking crew just doing something wrong in the configuration of these new switches? While will the old switches work "auto/auto", but the new switches won't?? HELP!!....and Thanks!! M

    Read the article

  • Cascading KVM switches

    - by einpoklum
    I have a not-so-small number of computers (say, 5) which I want to access with a single keyboard, USB and monitor. I can get an 8-port KVM switch, which is a pretty expensive piece of hardware; however, in theory, I should be able to cascade KVM switches: Have one 4-port KVM switch between 2 other KVMs (a 2-port and a 4-port). Is this doable (with typical off-the-shelf switches and cables)? Has anyone had experience doing this? Note: I'm interested in USB-only for the keyboard and mouse, and either VGA or DVI for the display. Audio and PS/2 connections are irrelevant for me..

    Read the article

  • In Opera 11, how can I set up shortcuts to switch to specific tabs?

    - by gphilip
    In Firefox on Linux, we can use Alt+1, Alt+2, etc. to switch to the first, second, etc. tabs, till the 9th tab. This is very useful to switch between tabs. In Opera 11 on Linux, I couldn't find a way to do this: the only way to switch among tabs seems to be to use Ctrl+Tab and then cycle till we reach the tab that we want. Needless to say, this "linear access" method is slower (and more annoying) than the random access available in FF. So my question is: How can I set up shortcuts in Opera 11 on Linux so that I can switch to one of the first nine tabs using a numbered shortcut?

    Read the article

  • Should the MAC Tables on a switch Stack be the same between sessions?

    - by Kyle Brandt
    According to Cisco's documentation: "The MAC address tables on all stack members are synchronized. At any given time, each stack member has the same copy of the address tables for each VLAN." However, when logged into the switch I see the following: ny-swstack01#show mac ad | inc Total Total Mac Addresses for this criterion: 222 ny-swstack01#ses 2 ny-swstack01-2#show mac ad | inc Total Total Mac Addresses for this criterion: 229 ny-swstack01-2#exit ny-swstack01#ses 3 ny-swstack01-3#show mac ad | inc Total Total Mac Addresses for this criterion: 229 ny-swstack01-3#exit ny-swstack01#ses 4 ny-swstack01-4#show mac ad | inc Total Total Mac Addresses for this criterion: 235 ny-swstack01-4#exit ny-swstack01#show mac ad | inc Total Total Mac Addresses for this criterion: 222 Going back and forth this isn't just because it is changing over time either, within certain sessions there are entries that I don't seen from the master session. We are currently waiting to hear back on CIsco from this, but has anyone run into this before? I stumbled upon this when looking into Unicast flooding, one of the hosts that is a destination MAC of flooding has a MAC entry that appears in session 3, but nowhere else. Also, I checked an all sessions show the same aging time.

    Read the article

< Previous Page | 52 53 54 55 56 57 58 59 60 61 62 63  | Next Page >