Search Results

Search found 15273 results on 611 pages for 'subtle array'.

Page 570/611 | < Previous Page | 566 567 568 569 570 571 572 573 574 575 576 577  | Next Page >

  • Is the Leptonica implementation of 'Modified Median Cut' not using the median at all?

    - by TheCodeJunkie
    I'm playing around a bit with image processing and decided to read up on how color quantization worked and after a bit of reading I found the Modified Median Cut Quantization algorithm. I've been reading the code of the C implementation in Leptonica library and came across something I thought was a bit odd. Now I want to stress that I am far from an expert in this area, not am I a math-head, so I am predicting that this all comes down to me not understanding all of it and not that the implementation of the algorithm is wrong at all. The algorithm states that the vbox should be split along the lagest axis and that it should be split using the following logic The largest axis is divided by locating the bin with the median pixel (by population), selecting the longer side, and dividing in the center of that side. We could have simply put the bin with the median pixel in the shorter side, but in the early stages of subdivision, this tends to put low density clusters (that are not considered in the subdivision) in the same vbox as part of a high density cluster that will outvote it in median vbox color, even with future median-based subdivisions. The algorithm used here is particularly important in early subdivisions, and 3is useful for giving visible but low population color clusters their own vbox. This has little effect on the subdivision of high density clusters, which ultimately will have roughly equal population in their vboxes. For the sake of the argument, let's assume that we have a vbox that we are in the process of splitting and that the red axis is the largest. In the Leptonica algorithm, on line 01297, the code appears to do the following Iterate over all the possible green and blue variations of the red color For each iteration it adds to the total number of pixels (population) it's found along the red axis For each red color it sum up the population of the current red and the previous ones, thus storing an accumulated value, for each red note: when I say 'red' I mean each point along the axis that is covered by the iteration, the actual color may not be red but contains a certain amount of red So for the sake of illustration, assume we have 9 "bins" along the red axis and that they have the following populations 4 8 20 16 1 9 12 8 8 After the iteration of all red bins, the partialsum array will contain the following count for the bins mentioned above 4 12 32 48 49 58 70 78 86 And total would have a value of 86 Once that's done it's time to perform the actual median cut and for the red axis this is performed on line 01346 It iterates over bins and check they accumulated sum. And here's the part that throws me of from the description of the algorithm. It looks for the first bin that has a value that is greater than total/2 Wouldn't total/2 mean that it is looking for a bin that has a value that is greater than the average value and not the median ? The median for the above bins would be 49 The use of 43 or 49 could potentially have a huge impact on how the boxes are split, even though the algorithm then proceeds by moving to the center of the larger side of where the matched value was.. Another thing that puzzles me a bit is that the paper specified that the bin with the median value should be located, but does not mention how to proceed if there are an even number of bins.. the median would be the result of (a+b)/2 and it's not guaranteed that any of the bins contains that population count. So this is what makes me thing that there are some approximations going on that are negligible because of how the split actually takes part at the center of the larger side of the selected bin. Sorry if it got a bit long winded, but I wanted to be as thoroughas I could because it's been driving me nuts for a couple of days now ;)

    Read the article

  • Entity System with C++ templates

    - by tommaisey
    I've been getting interested in the Entity/Component style of game programming, and I've come up with a design in C++ which I'd like a critique of. I decided to go with a fairly pure Entity system, where entities are simply an ID number. Components are stored in a series of vectors - one for each Component type. However, I didn't want to have to add boilerplate code for every new Component type I added to the game. Nor did I want to use macros to do this, which frankly scare me. So I've come up with a system based on templates and type hinting. But there are some potential issues I'd like to check before I spend ages writing this (I'm a slow coder!) All Components derive from a Component base class. This base class has a protected constructor, that takes a string parameter. When you write a new derived Component class, you must initialise the base with the name of your new class in a string. When you first instantiate a new DerivedComponent, it adds the string to a static hashmap inside Component mapped to a unique integer id. When you subsequently instantiate more Components of the same type, no action is taken. The result (I think) should be a static hashmap with the name of each class derived from Component that you instantiate at least once, mapped to a unique id, which can by obtained with the static method Component::getTypeId ("DerivedComponent"). Phew. The next important part is TypedComponentList<typename PropertyType>. This is basically just a wrapper to an std::vector<typename PropertyType> with some useful methods. It also contains a hashmap of entity ID numbers to slots in the array so we can find Components by their entity owner. Crucially TypedComponentList<> is derived from the non-template class ComponentList. This allows me to maintain a list of pointers to ComponentList in my main ComponentManager, which actually point to TypedComponentLists with different template parameters (sneaky). The Component manager has template functions such as: template <typename ComponentType> void addProperty (ComponentType& component, int componentTypeId, int entityId) and: template <typename ComponentType> TypedComponentList<ComponentType>* getComponentList (int componentTypeId) which deal with casting from ComponentList to the correct TypedComponentList for you. So to get a list of a particular type of Component you call: TypedComponentList<MyComponent>* list = componentManager.getComponentList<MyComponent> (Component::getTypeId("MyComponent")); Which I'll admit looks pretty ugly. Bad points of the design: If a user of the code writes a new Component class but supplies the wrong string to the base constructor, the whole system will fail. Each time a new Component is instantiated, we must check a hashed string to see if that component type has bee instantiated before. Will probably generate a lot of assembly because of the extensive use of templates. I don't know how well the compiler will be able to minimise this. You could consider the whole system a bit complex - perhaps premature optimisation? But I want to use this code again and again, so I want it to be performant. Good points of the design: Components are stored in typed vectors but they can also be found by using their entity owner id as a hash. This means we can iterate them fast, and minimise cache misses, but also skip straight to the component we need if necessary. We can freely add Components of different types to the system without having to add and manage new Component vectors by hand. What do you think? Do the good points outweigh the bad?

    Read the article

  • Making user input/math on data fast, unlike excel type programs

    - by proGrammar
    I'm creating a research platform solely for myself to do some research on data. Programs like excel are terribly slow for me so I'm trying to come up with another solution. Originally I used excel. A1 was the cell that contained the data and all other cells in use calculated something on A1, or on other cells, that all could be in the end traced to A1. A1 was like an element of an array, I then I incremented it to go through all my data. This was way too slow. So the only other option I found originally was to hand code in c# the calculations inside a loop. Then I simply recompiled each time I changed my math. This was terribly slow to do and I had to order everything correctly so things would update correctly (dependencies). I could have also used events, but hand coding events for each cell like calculation would also be very slow. Next I created an application to read Excel and to perfectly imitate it. Which is what I now use. Basically I write formulas onto a fraction of my data to get live results inside excel. Then my program reads excel, writes another c# program, compiles it, and runs that program which runs my excel created formulas through a lot more data a whole lot faster. The advantage being my application dependency sorts everything (or I could use events) so I don't have to (like excel does) And of course the speed. But now its not a single application anymore. Instead its 2 applications, one which only reads my formulas and writes another program. The other one being the result which only lives for a short while before I do other runs through my data with different formulas / settings. So I can't see multiple results at one time without introducing even more programs like a database or at least having the 2 applications talking to each other. My idea was to have a dll that would be written, compiled, loaded, and unloaded again and again. So a self-updating program, sort of. But apparently that's not possible without another appdomain which means data has to be marshaled to be moved between the appdomains. Which would slow things down, not for summaries, but for other stuff I need to do with all my data. I'm also forgetting to mention a huge problem with restarting an application again and again which is having to reload ALL my data into memory again and again. But its still a whole lot faster than excel. I'm really super puzzled as to what people do when they want to research data fast. I'm completely unable to have a program accept user input and having it fast. My understanding is that it would have to do things like excel which is to evaluate strings again and again. So my only option is to repeatedly compile applications. Do I have a correct understanding on computer science? I've only just began programming, and didn't think I would have to learn much to do some simple math on data. My understanding is its either compiling my user defined stuff to a program or evaluating them from a string or something stupid again and again. And my only option is to probably switch operating systems or something to be able to have a program compile and run itself without stopping (writing/compiling dll, loading dll to program, unloading, and repeating). Can someone give me some idea on how computers work? Is anything better possible? Like a running program, that can accept user input and compile it and then unload it later? I mean heck operating systems dont need to be RESTARTED with every change to user input. What is this the cave man days? Sorry, it's just so super frustrating not knowing what one can do, and can't do. If only I could understand and learn this stuff fast enough.

    Read the article

  • i want to access mysql database table on given conditions in drop down menu [on hold]

    - by user3909877
    as the code below is accesing the database table directly but i want it to display the table content on giving conditions in drop down menu like when i select islamabad in one drop down menu and lahore in other as given in code and press search buttonn then it display the table flights.but it is displaying it directly <p class="h2">Quick Search</p> <div class="sb2_opts"> <p> </p> <form method="post" action=""> <p>Enter your source and destination.</p> <p> From:</p> <select name="from"> <option value="Islamabad">Islamabad</option> <option value="Lahore">Lahore</option> <option value="murree">Murree</option> <option value="Muzaffarabad">Muzaffarabad</option> </select> <p> To:</p> <select name="To"> <option value="Islamabad">Islamabad</option> <option value="Lahore">Lahore</option> <option value="murree">Murree</option> <option value="Muzaffarabad">Muzaffarabad</option> </select> <input type="submit" value="search" /> </form> </form> </table> <?php $from = isset($_POST['from'])?$_POST['from']:''; $to = isset($_POST['to'])?$_POST['to']:''; if( $from =='Islamabad'){ if($to == 'Lahore'){ $db_host = 'localhost'; $db_user = 'root'; $database = 'homedb'; $table = 'flights'; if (!mysql_connect($db_host, $db_user)) die("Can't connect to database"); if (!mysql_select_db($database)) die("Can't select database"); $result = mysql_query("SELECT * FROM {$table}"); if (!$result) { die("Query to show fields from table failed"); } $result = mysql_query("SELECT * FROM {$table}"); if (!$result) { die("Query to show fields from table failed"); } $fields_num = mysql_num_fields($result); echo "<h1>Table: {$table}</h1>"; echo "<table border='1'><tr>"; while($row = mysql_fetch_row($result)) { echo "<tr>"; // $row is array... foreach( .. ) puts every element // of $row to $cell variable foreach($row as $cell) echo "<td>$cell</td>"; echo "</tr>\n"; } } } mysqli_close($con); ?>

    Read the article

  • android client not working [migrated]

    - by Syeda Zunairah
    i have a java client and c# server the server code is static Socket listeningSocket; static Socket socket; static Thread thrReadRequest; static int iPort = 4444; static int iConnectionQueue = 100; static void Main(string[] args) { Console.WriteLine(IPAddress.Parse(getLocalIPAddress()).ToString()); try { listeningSocket = new Socket(AddressFamily.InterNetwork, SocketType.Stream, ProtocolType.Tcp); //listeningSocket.Bind(new IPEndPoint(0, iPort)); listeningSocket.Bind(new IPEndPoint(IPAddress.Parse(getLocalIPAddress()), iPort)); listeningSocket.Listen(iConnectionQueue); thrReadRequest = new Thread(new ThreadStart(getRequest)); thrReadRequest.Start(); } catch (Exception e) { Console.WriteLine("Winsock error: " + e.ToString()); //throw; } } static private void getRequest() { int i = 0; while (true) { i++; Console.WriteLine("Outside Try i = {0}", i.ToString()); try { socket = listeningSocket.Accept(); // Receiving //byte[] rcvLenBytes = new byte[4]; //socket.Receive(rcvLenBytes); //int rcvLen = System.BitConverter.ToInt32(rcvLenBytes, 0); //byte[] rcvBytes = new byte[rcvLen]; //socket.Receive(rcvBytes); //String formattedBuffer = System.Text.Encoding.ASCII.GetString(rcvBytes); byte[] buffer = new byte[socket.SendBufferSize]; int iBufferLength = socket.Receive(buffer, 0, buffer.Length, 0); Console.WriteLine("Received {0}", iBufferLength); Array.Resize(ref buffer, iBufferLength); string formattedBuffer = Encoding.ASCII.GetString(buffer); Console.WriteLine("Data received by Client: {0}", formattedBuffer); if (formattedBuffer == "quit") { socket.Close(); listeningSocket.Close(); Environment.Exit(0); } Console.WriteLine("Inside Try i = {0}", i.ToString()); Thread.Sleep(500); } catch (Exception e) { //socket.Close(); Console.WriteLine("Receiving error: " + e.ToString()); Console.ReadKey(); //throw; } finally { socket.Close(); //listeningsocket.close(); } } } static private string getLocalIPAddress() { IPHostEntry host; string localIP = ""; host = Dns.GetHostEntry(Dns.GetHostName()); foreach (IPAddress ip in host.AddressList) { if (ip.AddressFamily == AddressFamily.InterNetwork) { localIP = ip.ToString(); break; } } return localIP; } } and the jave android code is private TCPClient mTcpClient; @Override protected void onCreate(Bundle savedInstanceState) { super.onCreate(savedInstanceState); setContentView(R.layout.activity_main); final EditText editText = (EditText) findViewById(R.id.edit_message); Button send = (Button)findViewById(R.id.sendbutton); // connect to the server new connectTask().execute(""); send.setOnClickListener(new View.OnClickListener() { @Override public void onClick(View view) { String message = editText.getText().toString(); //sends the message to the server if (mTcpClient != null) { mTcpClient.sendMessage(message); } editText.setText(""); } }); } @Override public boolean onCreateOptionsMenu(Menu menu) { getMenuInflater().inflate(R.menu.main, menu); return true; } public class connectTask extends AsyncTask<String,String,TCPClient> { @Override protected TCPClient doInBackground(String... message) { mTcpClient = new TCPClient(new TCPClient.OnMessageReceived() { @Override public void messageReceived(String message) { publishProgress(message); } }); mTcpClient.run(); return null; } @Override protected void onProgressUpdate(String... values) { super.onProgressUpdate(values); } } } when i run the server it gives output of try i=1. can any one tell me what to do next

    Read the article

  • 3Ware 9650SE RAID-6, two degraded drives, one ECC, rebuild stuck

    - by cswingle
    This morning I came in the office to discover that two of the drives on a RAID-6, 3ware 9650SE controller were marked as degraded and it was rebuilding the array. After getting to about 4%, it got ECC errors on a third drive (this may have happened when I attempted to access the filesystem on this RAID and got I/O errors from the controller). Now I'm in this state: > /c2/u1 show Unit UnitType Status %RCmpl %V/I/M Port Stripe Size(GB) ------------------------------------------------------------------------ u1 RAID-6 REBUILDING 4%(A) - - 64K 7450.5 u1-0 DISK OK - - p5 - 931.312 u1-1 DISK OK - - p2 - 931.312 u1-2 DISK OK - - p1 - 931.312 u1-3 DISK OK - - p4 - 931.312 u1-4 DISK OK - - p11 - 931.312 u1-5 DISK DEGRADED - - p6 - 931.312 u1-6 DISK OK - - p7 - 931.312 u1-7 DISK DEGRADED - - p3 - 931.312 u1-8 DISK WARNING - - p9 - 931.312 u1-9 DISK OK - - p10 - 931.312 u1/v0 Volume - - - - - 7450.5 Examining the SMART data on the three drives in question, the two that are DEGRADED are in good shape (PASSED without any Current_Pending_Sector or Offline_Uncorrectable errors), but the drive listed as WARNING has 24 uncorrectable sectors. And, the "rebuild" has been stuck at 4% for ten hours now. So: How do I get it to start actually rebuilding? This particular controller doesn't appear to support /c2/u1 resume rebuild, and the only rebuild command that appears to be an option is one that wants to know what disk to add (/c2/u1 start rebuild disk=<p:-p...> [ignoreECC] according to the help). I have two hot spares in the server, and I'm happy to engage them, but I don't understand what it would do with that information in the current state it's in. Can I pull out the drive that is demonstrably failing (the WARNING drive), when I have two DEGRADED drives in a RAID-6? It seems to me that the best scenario would be for me to pull the WARNING drive and tell it to use one of my hot spares in the rebuild. But won't I kill the thing by pulling a "good" drive in a RAID-6 with two DEGRADED drives? Finally, I've seen reference in other posts to a bad bug in this controller that causes good drives to be marked as bad and that upgrading the firmware may help. Is flashing the firmware a risky operation given the situation? Is it likely to help or hurt wrt the rebuilding-but-stuck-at-4% RAID? Am I experiencing this bug in action? Advice outside the spiritual would be much appreciated. Thanks.

    Read the article

  • exchange web service C# code send email from home

    - by KK
    Is it possible to write C# code as below and send email using my home network? I have a valid user name and password on that exchange server. Is there any configuration that I can set to achieve this? BTW this code blow works when I run it within office network. I want this code to work when run from any network. String cMSExchangeWebServiceURL = (String)System.Configuration.ConfigurationSettings.AppSettings["MSExchangeWebServiceURL"]; String cEmail = (String)System.Configuration.ConfigurationSettings.AppSettings["Cemail"]; String cPassword = (String)System.Configuration.ConfigurationSettings.AppSettings["Cpassword"]; String cTo = (String)System.Configuration.ConfigurationSettings.AppSettings["CTo"]; ExchangeServiceBinding esb = new ExchangeServiceBinding(); esb.Timeout = 1800000; esb.AllowAutoRedirect = true; esb.UseDefaultCredentials = false; esb.Credentials = new NetworkCredential(cEmail, cPassword); esb.Url = cMSExchangeWebServiceURL; ServicePointManager.ServerCertificateValidationCallback += delegate(object sender1, X509Certificate certificate, X509Chain chain, SslPolicyErrors sslPolicyErrors) { return true; }; // Create a CreateItem request object CreateItemType request = new CreateItemType(); // Setup the request: // Indicate that we only want to send the message. No copy will be saved. request.MessageDisposition = MessageDispositionType.SendOnly; request.MessageDispositionSpecified = true; // Create a message object and set its properties MessageType message = new MessageType(); message.Subject = subject; message.Body = new TestOutgoingEmailServer.com.cogniti.mail1.BodyType(); message.Body.BodyType1 = BodyTypeType.HTML; message.Body.Value = body; message.ToRecipients = new EmailAddressType[3]; message.ToRecipients[0] = new EmailAddressType(); //message.ToRecipients[1] = new EmailAddressType(); //message.ToRecipients[2] = new EmailAddressType(); message.ToRecipients[0].EmailAddress = "[email protected]"; message.ToRecipients[0].RoutingType = "SMTP"; //message.CcRecipients = new EmailAddressType[1]; //message.CcRecipients[0] = new EmailAddressType(); //message.CcRecipients[0].EmailAddress = toEmailAddress.ElementAt(1).ToString(); //message.CcRecipients[0].RoutingType = "SMTP"; //There are some more properties in MessageType object //you can set all according to your requirement // Construct the array of items to send request.Items = new NonEmptyArrayOfAllItemsType(); request.Items.Items = new ItemType[1]; request.Items.Items[0] = message; // Call the CreateItem EWS method. CreateItemResponseType response = esb.CreateItem(request);

    Read the article

  • IRP_MJ_WRITE latency up to 15 seconds

    - by racitup
    We have written an application that performs small (22kB) writes to multiple files at once (one thread performing asynchronous queued writes to multiple locations on behalf of other threads) on the same local volume (RAID1). 99.9% of the writes are low-latency but occasionally (maybe every minute or two) we get one or two huge latency writes (I have seen 10 seconds and above) without any real explanation. Platform: Win2003 Server with NTFS. Monitoring: Sysinternals Process Monitor (see link below) and our own application logging. We have tried multiple things to try and solve this that have been gleaned from a few websites, e.g.: Making the first part of file names unique to aid 8.3 name generation Writing files to multiple directories Changing Intel Disk Write Caching Windows File/Printer Sharing Minimize memory used Balance Maximize data throughput for file sharing Maximize data throughput for network applications System-Advanced-Performance-Advanced NtfsDisableLastAccessUpdate - use fsutil behavior set disablelastaccess 1 disable 8.3 name generation - use "fsutil behavior set disable8dot3 1" + restart Enable a large size file system cache Disable paging of the kernel code IO Page Lock Limit Turn Off (or On) the Indexing Service But nothing seems to make much difference. There's a whole host of things we haven't tried yet but we wondered if anyone had come across the same problem, a reason and a solution (programmatic or not)? We can reproduce the problem using IOMeter and a simple setup: Start IOMeter and remove all but the first worker thread in 'Topology' using the disconnect button. Select the Worker thread and put a cross in the box next to the disk you want to use in the Disk Targets tab and put '2000000' in Maximum Disk Size (NOTE: must have at least 1GB free space; sector size is 512 bytes) Next create a new access specification and add it to the worker thread: Transfer Request Size = 22kB 100% Sequential Percent of Access Spec = 100% Percent Read/Write = 100% Write Change Results Display Update Frequency to 5 seconds, Test Setup Run Time to 20 seconds and both 'Number of Workers to Spawn Automatically' settings to zero. Select the Worker Thread in the Topology panel and hit the Duplicate Worker button 59 times to create 60 threads with identical settings. Hit the 'Go' button (green flag) and monitor the Results tab. The 'Maximum I/O Response Time (ms)' always hits at least 3500 on our machine. Our machine isn't exactly slow (Xeon 8 core rack server with 4GB and onboard RAID). I'd be interested to see what other people get. We have a feeling it might be something to do with the NTFS filesystem (ours is currently 75% full of fragmented files) and we are going to try a few things around this principle. But it is also related to disk performance since we don't see it on a RAMDisk and it's not as severe on a RAID10 array. Any help is much appreciated. Richard Right-click and select 'Open Link in New Tab': ProcMon Result

    Read the article

  • uploading via http post (multipart/form-data) silently fails with big files

    - by matteo
    When uploading multipart/form-data forms via a http post request to my apache web server, very big files (i.e. 30MB) are silently discarded. On the server side all looks as if the attached file was received with 0 bytes size. On the client side all looks like it had been uploaded succesfully (it takes the expected long time to upload and the browser gives no error message). On the server, nothing is logged into the error log. An entry is logged into the access log as if everything was ok (a post request and a 200 ok response). These uploads are being posted to a php script. In the php script, If I print_r $_FILES, I see the following information for the relevant file: [file5] => Array ( [name] => MOV023.3gp [type] => video/3gpp [tmp_name] => /tmp/phpgOdvYQ [error] => 0 [size] => 0 ) Note both [error] = 0 (which should mean no error) and [size] = 0 (as if the file was empty). My php script runs fine and receives all the rest of the data except these files. move_uploaded_file succeeds on these files and actually copies them as 0byte files. I've already changed the php directives max_upload_size to 50M and post_max_size to 200M, so neither the single file nor the request exceed any size limit. max_execution_time is not relevant, because the time to transfer the data does not count; and I've increased max_input_time to 1000 seconds, though this shouldn't be necessary since this is the time taken to parse the input data, not the time taken to upload it. Is there any apache configuration, prior to php, that could be causing these files to be discarded even prior to php execution? Some limit in size or in upload time? I've read about a default 300 seconds timeout limit, but this should apply to the time the connection is idle, not the time it takes while actually transferring data, right? Needless to say, uploads with all exactly identical conditions (including file format, client and everything) except smaller file size, work seamlessly, so the issue is clearly related to the file or request size, or to the time it takes to send it.

    Read the article

  • MD3200 - 3 to 4x less throughput than MD1220. Am I missing something here?

    - by Igor Polishchuk
    I have two R710 servers with similar configuration. One in my office has MD1220 attached. Another one in the datacenter of my hosting services vendor has MD3200. I'm getting significantly worse throughput from MD3200 at my vendors setup. I'm mostly interested in sequential writes, and I'm getting these results in bonnie++ and dd tests: Seq. writes on MD1220 in my office: 1.1 GB/s - bonnie++, 1.3GB/s - dd Seq. writes on MD3200 at my vendor's: 240MB/s - bonnie++, 310MB/s - dd Unfortunately, I could not test the exactly the same configurations, but the two I have should be comparable. If anything, my good performing environment is cheaper than the bad performing. I expect at least similar throughput from these two setups. My vendor cannot really help me. Hopefully, somebody more familiar with the DAS performance can look at it and tell if I'm missing something here and my expectations are too high. To summarize, the question here is it reasonable to expect about 100MB/s of sequential write throughput per each couple of drives in RAID10 on MD3200? Is there any trick to enable such performance in MD3200 with dual controller as opposed to simple MD1220 with a single H800 adapter? More details about the configurations: A good one in my office: Dell R710 2CPU X5650 @ 2.67GHz 12 cores 96GB DDR3, OS: RHEL 5.5, kernel 2.6.18-194.26.1.el5 x86_64 20x300GB 2.5" SAS 10K in a single RAID10 1MB chunk size on MD1220 + Dell H800 I/O controller with 1GB cache in the host Not so good one at my vendor's: Dell R710 2CPU L5520 @ 2.27GHz 8 cores 144GB DDR3, OS: RHEL 5.5, kernel 2.6.18-194.11.4.el5 x86_64 20x146GB 2.5" SAS 15K in a single RAID10 512KB chunk size, Dell MD3200, 2 I/O controllers in array with 1GB cache each Additional information. I've also ran the same tests on the same vendor's host, but the storage was: two raids of 14x146GB 15K RPM drives RAID 10, striped together on the OS level on MD3000+MD1000. The performance was about 25% worse than on MD3200 despite having more drives. When I ran similar tests on the internal storage of my vendor's host (2x146GB 15K RPM drives RAID1, Perc 6i) I've got about 128MB/s seq. writes. Just two internal drives gave me about a half of 20 drives' throughput on MD3200. The random I/O performance of the MD3200 setup is ok, it gives me at least 1300 IOPS. I'm mostly have problems with sequentioal I/O throughput. Thank you for looking into it. Regards Igor

    Read the article

  • order of operations for environment variables

    - by alyda
    I want to understand how environment variables are set and reset (overridden). I'm running Apache/2.2.24 (Unix) PHP/5.4.14 on a mac . My theory is this: Environment vars can be set in bash, then they can be overwritten with httpd.conf preceding a VirtualHost directive that precedes php.ini, which can then be overwritten by .htaccess (if allowable) and finally by PHP I tried the following: setting environment variable in bash: I added export ENVIRONMENT='local' to my ~/.bashrc file, restarted apache and did not get any output from print_r($_ENV); (in a simple index.php file at the root of my webserver). I also tried putting ENVIRONMENT='local' into /etc/environment, and restarting apache, nothing, as well as /etc/bashrc, restart apache. still nothing. setting environment variable in httpd.conf: I added SetEnv ENVIRONMENT 'local-httpd to the end of my /etc/apache2/httpd.conf file (but before I load other conf files, such as virtual host [Include /private/etc/apache2/other/*.conf]). I now see the variable in the array print_r($_SERVER); but not print_r($_ENV);. setting environment variable in httpd-vhosts.conf: I added SetEnv ENVIRONMENT 'local-vhost to my /etc/apache2/extra/httpd-vhosts.conf file in my generic directive that points to my default document root. I now see the variable has been overwritten (to local-vhost from local-httpd, so I know where the variable is getting set). setting environment variable in php.ini: while searching for a proper place to put my environment variable, I noticed that variables_order = "GPCS" was set to the production value rather than EGPCS. I changed it, restarted my server and found that I was now getting output for print_r($_ENV); but not my expected custom variable. It also appears that I am not able to set a custom variable in this file. Please tell me if I am wrong setting environment variable in .htaccess: I added SetEnv ENVIRONMENT 'local-htaccess'. This worked as expected, overwriting all other values that were set. setting / overwriting environment variable in PHP: if (...) { putenv('ENVIRONMENT=local'); } I'm asking this question because I have a lot of local and remote testing servers, some of which may or may not allow me access to modify httpd, httpd-vhost, php.ini or environment variables. I want to understand what is best for those difference scenarios (shared hosting, heroku, local servers, etc) I obviously don't know how to properly set the environment variable in bash in a way that php can use it, I'd like to know how to do that (as I think Heroku does something similar with heroku config set...)

    Read the article

  • OCZ Vertex 2 not recognized by Ubuntu installer

    - by Zsub
    As I boot into the Ubuntu 10.10 (or 11.04, doesn't matter) live environment or installer, it just refuses to recognise my Vertex 2. It reports the disk as ATA and not supporting smart, shows no serial number, and doesn't list the size correctly. All fdisk tells me is Unable to read /dev/sda (it's the only storage in the PC). I'm now running a temporary install of Windows 7 off of it, which worked like a charm, so where am I going wrong with Ubuntu... Specs: Asus M4N68T-M LE V2 (BIOS 0702, most recent) OCZ Vertex 2 SSD 60 GB Amd Athlon II X4 640 Patriot PSD34G13332 4GB DDR3 ram (two banks) EDIT I installed a second drive, installed Ubuntu on that and booted, it recognised the SSD just fine. I'm now trying to apt-get upgrade the live-environment. I wonder if there is any way to sort of install Ubuntu from Ubuntu (I boot into the working install on the other drive, install it on the SSD and then boot from the SSD). EDIT2 Ok, so that doesn't work. The install detects the SSD, however, it cannot format it. EDIT3 After a fresh boot I can read out SMART-data and even perform a read-benchmark, but if I try to format it, or do a write-bench, it'll crap out and after that it says SMART is not supported. So basically it seems I can't write to the disk, as it will stop working when I do, I will try to run repeated read-benchmarks to see if that has any effect. EDIT4 I'm running several read benchmarks on the drive right now, they give results that are to be expected from an SSD. If the read-benches don't fail, I can use fdisk on the disk, but it is now stuck trying to re-read the partition table after issueing the 'w' command. EDIT5 Parted Magic did recognize the drive and with hdparm -I even could tell me the drive was in a frozen state. I powercycled it (just pull out the plug from the SSD and plug it back in) and it wasn't frozen anymore. After that I could upgrade the firmware on the drive (still using Parted Magic) and format it to Ext4. After I rebooted into the Ubuntu installer, it wouldn't get recognized and hdparm didn't want to talk to it saying HDIO_DRIVE_CMD(identify) failed: Invalid exchange. EDIT6 For some reason if I enable one of the RAID controllers (the one the SSD is connected to, obviously) Ubuntu will let me format it, mount it and write to it. The installer also recognizes it. However if the raid controller is enabled but no array is defined the motherboard can't boot from it :(

    Read the article

  • SQL Server High Availability - Mirroring with MSCS?

    - by David
    I'm looking at options for high-availability for my SQL Server-powered application. The requirements are: HA protection from storage failure. Data accessibility when one of the DB servers is undergoing software updates (e.g. planned outage for Windows Update / SQL Server service-packs). Must not involve much in the way of hardware procurement. The application is an ASP.NET web application. The web application's users have their own database instances. I've seen two main options: SQL Server failover clustering, and SQL Server mirroring. I understand that SQL Server Failover Clustering requires the purchasing of a shared disk array and doesn't offer any protection if the shared storage goes down (so the documentation recommends to set up a Mirroring between two clusters). Database Mirroring seems the cheaper option (as it only requires two database servers and a simple witness box) - but I've heard it doesn't work well when you have a large number of databases. The application I'm developing involves giving each client their own database for their application - there could be hundreds of databases. Setting up the mirroring is no problem thanks to the automation systems we have in place. My final point concerns how failover works with respect to client connections - SQL Server Failover Clustering uses MSCS which means that the cluster is invisible to clients - a connection attempt might fail during the failover, but a simple reconnect will have it working again. However mirroring, as far as I know, requires that the client be aware of the mirrored partners: if the client cannot connect to the primary server then it tries the secondary server. I'm wondering how this work with respect to Connection Pooling in ASP.NET applications - does the client connection failovering mean that there's a potential 2-second (assuming 2000ms TCP timeout policy) pause when the connection pool tries the primary server on every connection attempt? I read somewhere that Mirroring can be used on top of MSCS which means that the client does not need to be aware of mirroring (so there wouldn't be any potential delays during connection, and also that no changes would need to be made to the client, not even the connection string) - however I'm finding it hard to get documentation or white papers on this approach. But if true, then it means the best method is then Mirroring (for HA) with MSCS (for client ignorance and connection performance). ...but how does this scale to a server instance that might contain hundreds of mirrored databases?

    Read the article

  • Using smartctl to get vendor specific Attributes from ssd drive behind a SmartArray P410 controller

    - by Lairsdragon
    Hi! Recently I have deployed some HP server with SSD's behind a SmartArray P410 controller. While not official supported from HP the server work well sofar. Now I like to get wear level info's, error statistics etc from the drive. While the SA P410 supports a passthru of the SMART Command to a single drive in the array the output I was not able to the the interesting things from the drive. In this case especially the value the Wear level indicator is from interest for me (Attr.ID 233), but this is ony present if the drive is directly attanched to a SATA Controller. smartctl on directly connected ssd: # smartctl -A /dev/sda smartctl version 5.38 [x86_64-unknown-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF READ SMART DATA SECTION === SMART Attributes Data Structure revision number: 5 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 3 Spin_Up_Time 0x0000 100 000 000 Old_age Offline In_the_past 0 4 Start_Stop_Count 0x0000 100 000 000 Old_age Offline In_the_past 0 5 Reallocated_Sector_Ct 0x0002 100 100 000 Old_age Always - 0 9 Power_On_Hours 0x0002 100 100 000 Old_age Always - 8561 12 Power_Cycle_Count 0x0002 100 100 000 Old_age Always - 55 192 Power-Off_Retract_Count 0x0002 100 100 000 Old_age Always - 29 232 Unknown_Attribute 0x0003 100 100 010 Pre-fail Always - 0 233 Unknown_Attribute 0x0002 088 088 000 Old_age Always - 0 225 Load_Cycle_Count 0x0000 198 198 000 Old_age Offline - 508509 226 Load-in_Time 0x0002 255 000 000 Old_age Always In_the_past 0 227 Torq-amp_Count 0x0002 000 000 000 Old_age Always FAILING_NOW 0 228 Power-off_Retract_Count 0x0002 000 000 000 Old_age Always FAILING_NOW 0 smartctl on P410 connected ssd: # ./smartctl -A -d cciss,0 /dev/cciss/c1d0 smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net (Right, it is complety empty) smartctl on P410 connected hdd: # ./smartctl -A -d cciss,0 /dev/cciss/c0d0 smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net Current Drive Temperature: 27 C Drive Trip Temperature: 68 C Vendor (Seagate) cache information Blocks sent to initiator = 1871654030 Blocks received from initiator = 1360012929 Blocks read from cache and sent to initiator = 2178203797 Number of read and write commands whose size <= segment size = 46052239 Number of read and write commands whose size > segment size = 0 Vendor (Seagate/Hitachi) factory information number of hours powered up = 3363.25 number of minutes until next internal SMART test = 12 Do I hunt here a bug, or is this a limitation of the p410 SMART cmd Passthru?

    Read the article

  • Linux RAID-0 performance doesn't scale up over 1 GB/s

    - by wazoox
    I have trouble getting the max throughput out of my setup. The hardware is as follow : dual Quad-Core AMD Opteron(tm) Processor 2376 16 GB DDR2 ECC RAM dual Adaptec 52245 RAID controllers 48 1 TB SATA drives set up as 2 RAID-6 arrays (256KB stripe) + spares. Software : Plain vanilla 2.6.32.25 kernel, compiled for AMD-64, optimized for NUMA; Debian Lenny userland. benchmarks run : disktest, bonnie++, dd, etc. All give the same results. No discrepancy here. io scheduler used : noop. Yeah, no trick here. Up until now I basically assumed that striping (RAID 0) several physical devices should augment performance roughly linearly. However this is not the case here : each RAID array achieves about 780 MB/s write, sustained, and 1 GB/s read, sustained. writing to both RAID arrays simultaneously with two different processes gives 750 + 750 MB/s, and reading from both gives 1 + 1 GB/s. however when I stripe both arrays together, using either mdadm or lvm, the performance is about 850 MB/s writing and 1.4 GB/s reading. at least 30% less than expected! running two parallel writer or reader processes against the striped arrays doesn't enhance the figures, in fact it degrades performance even further. So what's happening here? Basically I ruled out bus or memory contention, because when I run dd on both drives simultaneously, aggregate write speed actually reach 1.5 GB/s and reading speed tops 2 GB/s. So it's not the PCIe bus. I suppose it's not the RAM. It's not the filesystem, because I get exactly the same numbers benchmarking against the raw device or using XFS. And I also get exactly the same performance using either LVM striping and md striping. What's wrong? What's preventing a process from going up to the max possible throughput? Is Linux striping defective? What other tests could I run?

    Read the article

  • How to use Hardware RAID in Ubuntu Server

    - by user2071938
    I have an Adaptec RAID-Controller and created an RAID-1(Mirroring) succesfully. Now I have installed Ubuntu Server 12.04.3. When I type fdisk -l I get this output: bf@fileserver:~$ sudo fdisk -l Disk /dev/sda: 1000.2 GB, 1000204886016 bytes 255 heads, 63 sectors/track, 121601 cylinders, total 1953525168 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 4096 bytes I/O size (minimum/optimal): 4096 bytes / 4096 bytes Disk identifier: 0x00000000 Disk /dev/sda doesn't contain a valid partition table Disk /dev/sdb: 1000.2 GB, 1000204886016 bytes 255 heads, 63 sectors/track, 121601 cylinders, total 1953525168 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 4096 bytes I/O size (minimum/optimal): 4096 bytes / 4096 bytes Disk identifier: 0x00000000 Disk /dev/sdb doesn't contain a valid partition table Disk /dev/sdc: 80.0 GB, 80026361856 bytes 255 heads, 63 sectors/track, 9729 cylinders, total 156301488 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x0004c454 Device Boot Start End Blocks Id System /dev/sdc1 * 2048 499711 248832 83 Linux /dev/sdc2 501758 156301311 77899777 5 Extended /dev/sdc5 501760 156301311 77899776 8e Linux LVM Disk /dev/mapper/fileserver--vg-root: 75.6 GB, 75606523904 bytes 255 heads, 63 sectors/track, 9191 cylinders, total 147668992 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/mapper/fileserver--vg-root doesn't contain a valid partition table Disk /dev/mapper/ddf1_Data: 1000.1 GB, 1000065728512 bytes 255 heads, 63 sectors/track, 121584 cylinders, total 1953253376 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 4096 bytes I/O size (minimum/optimal): 4096 bytes / 4096 bytes Disk identifier: 0x00000000 Disk /dev/mapper/ddf1_Data doesn't contain a valid partition table Disk /dev/mapper/fileserver--vg-swap_1: 4160 MB, 4160749568 bytes 255 heads, 63 sectors/track, 505 cylinders, total 8126464 sectors Units = sectors of 1 * 512 = 512 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Disk /dev/mapper/fileserver--vg-swap_1 doesn't contain a valid partition table The 80 GB HDD is for the System The 1000.2 GB HDD should be for my data. But I'm a bit confused becauser there are listed two 1000.2 GB HDDs, due the Hardware RAID shoudln't there be only one HDD vissible to the OS? (I have two 1000.2 GB HDDs in an Raid-1 Array) dmraid gives me bf@fileserver:~$ sudo dmraid -r /dev/sdb: ddf1, ".ddf1_disks", GROUP, ok, 1953253376 sectors, data@ 0 /dev/sda: ddf1, ".ddf1_disks", GROUP, ok, 1953253376 sectors, data@ 0 so It seems to be ok? But how do I partitionate this disks and which one should I mount(sdb or sda?) Hope you can help me thx Florian

    Read the article

  • Best Processor for MediaSmart Server?

    - by Kent Boogaart
    I'm trying to figure out what the best possible processor is that I can stick in my HP MediaSmart server. I'm clueless when it comes to correlating CPUs to motherboards. I suspect it's the socket type I care about, but I worry that there's more to it. CPU-Z gives me (excerpt): Processors Information ------------------------------------------------------------------------- Processor 1 ID = 0 Number of cores 1 (max 1) Number of threads 1 (max 1) Name AMD Sempron LE-1150 Codename Sparta Specification AMD Sempron(tm) Processor LE-1150 Package Socket AM2 (940) CPUID F.F.1 Extended CPUID F.7F Brand ID 1 Core Stepping DH-G1 Technology 65 nm Core Speed 1000.0 MHz Multiplier x FSB 5.0 x 200.0 MHz HT Link speed 800.0 MHz Stock frequency 2000 MHz Instructions sets MMX (+), 3DNow! (+), SSE, SSE2, SSE3, x86-64 L1 Data cache 64 KBytes, 2-way set associative, 64-byte line size L1 Instruction cache 64 KBytes, 2-way set associative, 64-byte line size L2 cache 256 KBytes, 16-way set associative, 64-byte line size FID/VID Control yes Max FID 10.0x Max VID 1.350 V P-State FID 0x2 - VID 0x12 (5.0x - 1.100 V) P-State FID 0xA - VID 0x0C (9.0x - 1.250 V) P-State FID 0xC - VID 0x0A (10.0x - 1.300 V) K8 Thermal sensor yes K8 Revision ID 6.0 Attached device PCI device at bus 0, device 24, function 0 Attached device PCI device at bus 0, device 24, function 1 Attached device PCI device at bus 0, device 24, function 2 Attached device PCI device at bus 0, device 24, function 3 Chipset ------------------------------------------------------------------------- Northbridge SiS 761GX rev. 02 Southbridge SiS 966 rev. 59 Graphic Interface AGP AGP Revision 3.0 AGP Transfer Rate 8x AGP SBA supported, enabled Memory Type DDR2 Memory Size 2048 MBytes Channels Single Memory Frequency 200.0 MHz (CPU/5) CAS# latency (CL) 5.0 RAS# to CAS# delay (tRCD) 5 RAS# Precharge (tRP) 5 Cycle Time (tRAS) 15 Bank Cycle Time (tRC) 21 Command Rate (CR) 1T DMI ------------------------------------------------------------------------- DMI BIOS vendor Phoenix Technologies, LTD version R03 date 05/08/2008 DMI System Information manufacturer HP product MediaSmart Server version unknown serial CN68330DGH UUID A482007B-B0CC7593-DD11736A-407B7067 DMI Baseboard vendor Wistron model SJD4 revision A.0 serial unknown DMI System Enclosure manufacturer HP chassis type Desktop chassis serial unknown DMI Processor manufacturer AMD model AMD Sempron(tm) Processor LE-1150 clock speed 2000.0 MHz FSB speed 200.0 MHz multiplier 10.0x DMI Memory Controller correction 64-bit ECC Max module size 4096 MBytes DMI Memory Module designation A0 size 2048 MBytes (double bank) DMI Memory Module designation A1 DMI Memory Module designation A2 DMI Memory Module designation A3 DMI Port Connector designation PS/2 Mouse (internal) port type Mouse Port connector PS/2 connector PS/2 DMI Port Connector designation USB0 (external) port type USB DMI Physical Memory Array location Motherboard usage System Memory correction None max capacity 16384 MBytes max# of devices 4 DMI Memory Device designation A0 format DIMM type unknown total width 64 bits data width 64 bits size 2048 MBytes DMI Memory Device designation A1 format DIMM type unknown total width 64 bits data width 64 bits DMI Memory Device designation A2 format DIMM type unknown total width 64 bits data width 64 bits DMI Memory Device designation A3 format DIMM type unknown total width 64 bits data width 64 bits How do I figure out what options I have for an upgrade?

    Read the article

  • How do I parse file paths separated by a space in a string?

    - by user1130637
    Background: I am working in Automator on a wrapper to a command line utility. I need a way to separate an arbitrary number of file paths delimited by a single space from a single string, so that I may remove all but the first file path to pass to the program. Example input string: /Users/bobby/diddy dum/ding.mp4 /Users/jimmy/gone mia/come back jimmy.mp3 ... Desired output: /Users/bobby/diddy dum/ding.mp4 Part of the problem is the inflexibility on the Automator end of things. I'm using an Automator action which returns unescaped POSIX filepaths delimited by a space (or comma). This is unfortunate because: 1. I cannot ensure file/folder names will not contain either a space or comma, and 2. the only inadmissible character in Mac OS X filenames (as far as I can tell) is :. There are options which allow me to enclose the file paths in double or single quotes, or angle brackets. The program itself accepts the argument of the aforementioned input string, so there must be a way of separating the paths. I just do not have a keen enough eye to see how to do it with sed or awk. At first I thought I'll just use sed to replace every [space]/ with [newline]/ and then trim all but the first line, but that leaves the loophole open for folders whose names end with a space. If I use the comma delimiter, the same happens, just for a comma instead. If I encapsulate in double or single quotation marks, I am opening another can of worms for filenames with those characters. The image/link is the relevant part of my Automator workflow. -- UPDATE -- I was able to achieve what I wanted in a rather roundabout way. It's hardly elegant but here is working generalized code: path="/Users/bobby/diddy dum/ding.mp4 /Users/jimmy/gone mia/come back jimmy.mp3" # using colon because it's an inadmissible Mac OS X # filename character, perfect for separating # also, unlike [space], multiple colons do not collapse IFS=: # replace all spaces with colons colpath=$(echo "$path" | sed 's/ /:/g') # place words from colon-ized file path into array # e.g. three spaces -> three colons -> two empty words j=1 for word in $colpath do filearray[$j]="$word" j=$j+1 done # reconstruct file path word by word # after each addition, check file existence # if non-existent, re-add lost [space] and continue until found name="" for seg in "${filearray[@]}" do name="$name$seg" if [[ -f "$name" ]] then echo "$name" break fi name="$name " done All this trouble because the default IFS doesn't count "emptiness" between the spaces as words, but rather collapses them all.

    Read the article

  • Linux not picking up new partition correctly on emc pseudo device

    - by James
    Hi We have a database server running oracle rac. We were recently running out of space on the main LUN that it is attached to. I created a new 100GB LUN and concatenated this onto the existing LUN creating a new MetaLUN. After some messing I managed to get linux to recognise the new space. I then created a new partition in on the pseudo device, to use the new space. Previously when I have done this on other system the next step is to create an ASM disk on the new partition and add this disk to the oracle disk group. This however fails. I am aware of various issues with ASM and powerpath, but I don't think this is the issue here. As on while investigating the issue I discovered that one of the underlying logical device is not reflecting the size change. See below; Powermt displays all of the underlying logical units [root@XXXXX~]# powermt display dev=emcpowerd Pseudo name=emcpowerd CLARiiON ID=CKM00091500009 [VFRAC2] Logical device ID=6006016030312200787502866C65DE11 [LUN 30] state=alive; policy=CLAROpt; priority=0; queued-IOs=0 Owner: default=SP A, current=SP A Array failover mode: 1 ============================================================================== ---------------- Host --------------- - Stor - -- I/O Path - -- Stats --- ### HW Path I/O Paths Interf. Mode State Q-IOs Errors ============================================================================== 3 qla2xxx sde SP A0 active alive 0 0 3 qla2xxx sdj SP B0 active alive 0 0 4 qla2xxx sdo SP A1 active alive 0 0 4 qla2xxx sdt SP B1 active alive 0 0 Fdisk on the pseudo device shows correct space. [root@XXXXX ~]# fdisk -l /dev/emcpowerd Disk /dev/emcpowerd: 429.4 GB, 429496729600 bytes 255 heads, 63 sectors/track, 52216 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Device Boot Start End Blocks Id System /dev/emcpowerd1 1 39162 314568733+ 83 Linux /dev/emcpowerd2 39163 52216 104856255 83 Linux fdisk on one of the logical units is wrong [root@XXXXX~]# fdisk -l /dev/sde Disk /dev/sde: 322.1 GB, 322122547200 bytes 255 heads, 63 sectors/track, 39162 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Device Boot Start End Blocks Id System /dev/sde1 1 39162 314568733+ 83 Linux /dev/sde2 39163 52216 104856255 83 Linux fdisk on the rest of the units is fine [root@XXXXX ~]# fdisk -l /dev/sdj Disk /dev/sdj: 429.4 GB, 429496729600 bytes 255 heads, 63 sectors/track, 52216 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Device Boot Start End Blocks Id System /dev/sdj1 1 39162 314568733+ 83 Linux /dev/sdj2 39163 52216 104856255 83 Linux Also when I created the the partition linux did not create the any entries in the /dev directory for the second partition so I created these manually [root@XXXXX dev]# mknod sde2 b 8 66 [root@XXXXX dev]# ls -al sd[ejot]? brw-r----- 1 root disk 8, 65 Dec 29 14:20 sde1 brw-r--r-- 1 root disk 8, 66 Apr 8 20:31 sde2 brw-r----- 1 root disk 8, 145 Dec 29 14:19 sdj1 brw-r--r-- 1 root disk 8, 146 Apr 8 20:33 sdj2 brw-r----- 1 root disk 8, 225 Apr 6 23:12 sdo1 brw-r--r-- 1 root disk 8, 226 Apr 8 20:33 sdo2 brw-r----- 1 root disk 65, 49 Dec 29 14:19 sdt1 brw-r--r-- 1 root disk 65, 50 Apr 8 20:33 sdt2 This is a production server that we cannot easily reboot. Any ideas would be much appreciated. J

    Read the article

  • Areca 1280ml RAID6 volume set failed

    - by Richard
    Today we hit some kind of worst case scenario and are open to any kind of good ideas. Here is our problem: We are using several dedicated storage servers to host our virtual machines. Before I continue, here are the specs: Dedicated Server Machine Areca 1280ml RAID controller, Firmware 1.49 12x Samsung 1TB HDDs We configured one RAID6-set with 10 discs that contains one logical volume. We have two hot spares in the system. Today one HDD failed. This happens from time to time, so we replaced it. Upon rebuilding a second disc failed. Normally this is no fun. We stopped heavy IO-operations to ensure a stable RAID rebuild. Sadly the hot-spare disc failed while rebuilding and the whole thing stopped. Now we have the following situation: The controller says that the raid set is rebuilding The controller says that the volume failed It is a RAID 6 system and two discs failed, so the data has to be intact, but we cannot bring the volume online again to access the data. While searching we found the following leads. I don't know whether they are good or bad: Mirroring all the discs to a second set of drives. So we would have the possibility to try different things without loosing more than we already have. Trying to rebuild the array in R-Studio. But we have no real experience with the software. Pulling all drives, rebooting the system, changing into the areca controller bios, reinserting the HDDs one-by-one. Some people are saying that the brought the system online by this. Some are saying that the effect is zero. Some say, that they blew the whole thing. Using undocumented areca commands like "rescue" or "LeVel2ReScUe". Contacting a computer forensics service. But whoa... primary estimates by phone exceeded 20.000€. That's why we would kindly ask for help. Maybe we are missing the obvious? And yes of course, we have backups. But some systems lost one week of data, thats why we'd like to get the system up and running again. Any help, suggestions and questions are more than welcome.

    Read the article

  • Interop.Outlook.UserProperties.Add causing problem during connection time

    - by aanataliya
    Hi All, I have created a plug-in for outlook. Plug-in has only below code. private void OnNewOutlookInspector(Outlook.Inspector OutlookInsptr) { Outlook.MailItem MlItem = (Outlook.MailItem)OutlookInsptr.CurrentItem; //if I remove below line. Everything is working fine. MlItem.UserProperties.Add("INSPINIT", Outlook.OlUserPropertyType.olText , true , true ).Value = "1"; } public void OnConnection(object application, Extensibility.ext_ConnectMode connectMode, object addInInst, ref System.Array custom) { applicationObject = application; addInInstance = addInInst; MessageBox.Show("in connection new 2"); OutlkApp = (Outlook.Application)application; OutlkInsptrs = OutlkApp.Inspectors; OutlkInsptrs.NewInspector += new Outlook.InspectorsEvents_NewInspectorEventHandler(OnNewOutlookInspector); } Problem I am facing is, When I send HTML mail while plug-in is enabled, receiving end it is being received as a plain text. Below is the mail content along with the header and body at recieving end. x-sender: [email protected] x-receiver: [email protected] Received: from blr-s-07.pointcrossblr.com ([192.168.1.107]) by blr-ws-134.pointcrossblr.com with Microsoft SMTPSVC(6.0.2600.5949); Wed, 22 Dec 2010 17:11:02 +0530 Received: from blrws134 ([192.168.1.175]) by blr-s-07.pointcrossblr.com with Microsoft SMTPSVC(6.0.3790.4675); Wed, 22 Dec 2010 17:11:02 +0530 From: "Ashif Nataliya" <[email protected]> To: <[email protected]> Cc: <[email protected]> Subject: RTF FRM blr to pc.com cc blr-ws-134 Date: Wed, 22 Dec 2010 17:11:02 +0530 Message-ID: <[email protected]> MIME-Version: 1.0 Content-Type: multipart/mixed; boundary="----=_NextPart_000_00F7_01CBA1FB.36115580" X-Mailer: Microsoft Outlook 14.0 Content-Language: en-us X-MS-TNEF-Correlator: 00000000DCB2344DE8F50F4FBC91085BB5C06D55A4172000 thread-index: AcuhzRuTOBkvHPUnS1aLi9+cHNAWhA== Return-Path: [email protected] X-OriginalArrivalTime: 22 Dec 2010 11:41:02.0822 (UTC) FILETIME=[1C788860:01CBA1CD] This is a multipart message in MIME format. ------=_NextPart_000_00F7_01CBA1FB.36115580 Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: 7bit HTML Test Test Mail ------=_NextPart_000_00F7_01CBA1FB.36115580 Content-Type: application/ms-tnef; name="winmail.dat" Content-Transfer-Encoding: base64 Content-Disposition: attachment; filename="winmail.dat" // and some other code..... Any help is appreciated. Thanks.

    Read the article

  • Why is my new Phenom II 965 BE not significantly faster than my old Athlon 64 X2 4600+?

    - by Software Monkey
    I recently rebuilt my 5 year old computer. I upgraded all core components, in particular from an Athlon 64 X2 4600+ at 2.4 GHz with DDR2 800 to a Phenom II 965 BE (quad core) at 3.6 GHz with DDR3 1333 (actually 1600, but testing consistently detected memory errors at 1600). The motherboard is also much newer and better. The HDD's (x3), DVD writer and card reader are the same. The BIOS memory config is auto-everything except the base timing which I overrode to 1T instead of 2T. The BIOS CPU multiplier is slightly over-clocked to 3.6 GHz from the stock 3.4 GHz. I noticed compiling Java is slower than I expected. As it happens I have some (single-threaded) Java pattern-matching code which is CPU and memory bound and for which I have performance numbers recorded on a number of hardware platforms, including my old system. So I did a test run on the new equipment and was stunned to find that the numbers are only slightly better than my old system, about 25%. The data set it is operating on is a 148,975 character array, which should easily fit in caches, but in any event the new CPU has larger caches all around. The system was, of course, otherwise idle for the test and the test run is a timed 10 seconds to eliminate scheduling anomalies. A long while ago, when I upgraded only memory from DD2 667 to DDR2 800 there was no change in performance of this test, which subjectively supports that the test cycle does not need to (significantly) access main memory, but yes it is creating and garbage collecting a large number of objects in the process of this test (low millions of matches are found for the pattern set). I am about 99.999% certain the code hasn't changed since I last ran it on 2009-03-17 - but I can't easily retest the old hardware, because it is currently in pieces on my work-bench waiting to be built into a new computer for my kids. Note that Windows (XP) reports a CPU speed of 795 MHz unless I have some thing running. With stuff running it seems to jump all over the place each time I use ALT-Pause to display the system properties, everywhere from 795 MHz to 3.4 Ghz. So why might my shiny new hardware under-performing so badly? EDIT: The old memory was Mushkin DDR2 800 with timings set for auto which should have been 5-5-5-12. The new memory is Corsair DDR3 1600, running at 1333 with timings also auto which are 9-9-9-21. In both cases they are a paired set of dual channel DIMMs. I was waiting to ensure my system was stable before tweaking with memory timings.

    Read the article

  • Why MySQL sat for 2 minutes doing nothing?

    - by Alex R
    This was a one-time thing, not reproducible... But I saved the show innodb status output. Can anybody tell what's going on here? The simple insert took almost 3 minutes to complete. | InnoDB | | ===================================== 110201 15:58:10 INNODB MONITOR OUTPUT ===================================== Per second averages calculated from the last 34 seconds ---------- SEMAPHORES ---------- OS WAIT ARRAY INFO: reservation count 11963, signal count 11766 --Thread 1824 has waited at .\btr\btr0cur.c line 443 for 118.00 seconds the sema phore: S-lock on RW-latch at 09D6453C created in file .\buf\buf0buf.c line 550 a writer (thread id 1824) has reserved it in mode wait exclusive number of readers 1, waiters flag 1 Last time read locked in file .\buf\buf0flu.c line 599 Last time write locked in file .\btr\btr0cur.c line 443 Mutex spin waits 0, rounds 527817, OS waits 7133 RW-shared spins 2532, OS waits 1226; RW-excl spins 1652, OS waits 1118 ------------ TRANSACTIONS ------------ Trx id counter 0 95830 Purge done for trx's n:o < 0 95814 undo n:o < 0 0 History list length 11 LIST OF TRANSACTIONS FOR EACH SESSION: ---TRANSACTION 0 0, not started, OS thread id 3704 MySQL thread id 551, query id 2702112 localhost 127.0.0.1 root show innodb status ---TRANSACTION 0 95829, not started, OS thread id 3132 MySQL thread id 534, query id 2702020 localhost 127.0.0.1 root ---TRANSACTION 0 95828, not started, OS thread id 3152 MySQL thread id 527, query id 2701973 localhost 127.0.0.1 root ---TRANSACTION 0 95827, ACTIVE 118 sec, OS thread id 1824 inserting, thread decl ared inside InnoDB 500 mysql tables in use 1, locked 1 1 lock struct(s), heap size 320, 0 row lock(s) MySQL thread id 526, query id 2701972 localhost 127.0.0.1 root update INSERT INTO log_searchcriteria (userid,search_criteria,date,search_type) VALUES ( NAME_CONST('userid',NULL), NAME_CONST('search_criteria',_latin1' SELECT SQL_C ALC_FOUND_ROWS idx_search.CTCX_LATITUDE, idx_search.CTCX_LONGITUDE, idx_search.b uilding_id, idx_search.LN_LIST_NUMBER, idx_search.LP_LIST_PRICE, idx_search.HSN_ ADRESS_HOUSE_NUMBER, idx_search.STR_ADDRESS_STREET, idx_search.CP_ADDRESS_COMPAS S_POINT, idx_search.UN_UNIT, idx_search.CIT_CITY, idx_search.ZP_ZIP_CODE, idx_se arch.AR_AREA_NAME, idx_search.BR_BEDROOMS, idx_search.BTH_BATHS, idx_search.ST_S TATUS, idx_search.CTCX_STYLE_TYPE, idx_s -------- FILE I/O -------- I/O thread 0 state: wait Windows aio (insert buffer thread) I/O thread 1 state: wait Windows aio (log thread) I/O thread 2 state: wait Windows aio (read thread) I/O thread 3 state: wait Windows aio (write thread) Pending normal aio reads: 0, aio writes: 1, ibuf aio reads: 0, log i/o's: 0, sync i/o's: 0 Pending flushes (fsync) log: 0; buffer pool: 0 151006 OS file reads, 120758 OS file writes, 6844 OS fsyncs 0.00 reads/s, 0 avg bytes/read, 0.00 writes/s, 0.00 fsyncs/s ------------------------------------- INSERT BUFFER AND ADAPTIVE HASH INDEX ------------------------------------- Ibuf: size 1, free list len 5, seg size 7, 24664 inserts, 24664 merged recs, 4612 merges Hash table size 553253, node heap has 629 buffer(s) 0.00 hash searches/s, 0.00 non-hash searches/s --- LOG --- Log sequence number 5 2318193115 Log flushed up to 5 2318193115 Last checkpoint at 5 2318129891 0 pending log writes, 0 pending chkp writes 3036 log i/o's done, 0.00 log i/o's/second ---------------------- BUFFER POOL AND MEMORY ---------------------- Total memory allocated 213459462; in additional pool allocated 1720192 Dictionary memory allocated 240416 Buffer pool size 8192 Free buffers 0 Database pages 7563 Modified db pages 18 Pending reads 0 Pending writes: LRU 0, flush list 18, single page 0 Pages read 150973, created 28788, written 115137 0.00 reads/s, 0.00 creates/s, 0.00 writes/s No buffer pool page gets since the last printout -------------- ROW OPERATIONS -------------- 1 queries inside InnoDB, 0 queries in queue 1 read views open inside InnoDB Main thread id 2992, state: flushing buffer pool pages Number of rows inserted 794294, updated 89203, deleted 13698, read 1453084305 0.00 inserts/s, 0.00 updates/s, 0.00 deletes/s, 0.00 reads/s ---------------------------- END OF INNODB MONITOR OUTPUT ============================ Thanks

    Read the article

  • Is it possible to write C# code as below and send email using my home network?

    - by kedar karthik
    Is it possible to write C# code as below and send email using my home network? I have a valid user name and password on that exchange server. Is there any configuration that I can set to achieve this? BTW this code blow works when I run it within office network. I want this code to work when run from any network. String cMSExchangeWebServiceURL = (String)System.Configuration.ConfigurationSettings.AppSettings["MSExchangeWebServiceURL"]; String cEmail = (String)System.Configuration.ConfigurationSettings.AppSettings["Cemail"]; String cPassword = (String)System.Configuration.ConfigurationSettings.AppSettings["Cpassword"]; String cTo = (String)System.Configuration.ConfigurationSettings.AppSettings["CTo"]; ExchangeServiceBinding esb = new ExchangeServiceBinding(); esb.Timeout = 1800000; esb.AllowAutoRedirect = true; esb.UseDefaultCredentials = false; esb.Credentials = new NetworkCredential(cEmail, cPassword); esb.Url = cMSExchangeWebServiceURL; ServicePointManager.ServerCertificateValidationCallback += delegate(object sender1, X509Certificate certificate, X509Chain chain, SslPolicyErrors sslPolicyErrors) { return true; }; // Create a CreateItem request object CreateItemType request = new CreateItemType(); // Setup the request: // Indicate that we only want to send the message. No copy will be saved. request.MessageDisposition = MessageDispositionType.SendOnly; request.MessageDispositionSpecified = true; // Create a message object and set its properties MessageType message = new MessageType(); message.Subject = subject; message.Body = new TestOutgoingEmailServer.com.cogniti.mail1.BodyType(); message.Body.BodyType1 = BodyTypeType.HTML; message.Body.Value = body; message.ToRecipients = new EmailAddressType[3]; message.ToRecipients[0] = new EmailAddressType(); //message.ToRecipients[1] = new EmailAddressType(); //message.ToRecipients[2] = new EmailAddressType(); message.ToRecipients[0].EmailAddress = "[email protected]"; message.ToRecipients[0].RoutingType = "SMTP"; //message.CcRecipients = new EmailAddressType[1]; //message.CcRecipients[0] = new EmailAddressType(); //message.CcRecipients[0].EmailAddress = toEmailAddress.ElementAt(1).ToString(); //message.CcRecipients[0].RoutingType = "SMTP"; //There are some more properties in MessageType object //you can set all according to your requirement // Construct the array of items to send request.Items = new NonEmptyArrayOfAllItemsType(); request.Items.Items = new ItemType[1]; request.Items.Items[0] = message; // Call the CreateItem EWS method. CreateItemResponseType response = esb.CreateItem(request);

    Read the article

  • How to enable caching on Apache / Ubuntu Linux?

    - by Jim Mischel
    I have a large (several megabytes) XML file that's updated rather frequently (every 10 minutes or less) and gets a lot of traffic. I'd like to implement some caching to reduce bandwidth and server load. Looking at the Apache documents, I see a dizzying array of configuration options that involve various combinations of mod_expires, mod_headers, and mod_cache (and variants). I end up running in circles and the results aren't what I expect. I'm comfortable editing the various configuration files if I have some idea what I'm supposed to change. But at the moment I'm poking around in the dark and that's never a comfortable feeling. So, perhaps if I describe what I want, somebody here can take me by the hand and say, "This is what you need to do." Periodically, this file, call it "stuff.xml" is updated and a new version copied to the directory. The external url would be, for example, http://example.com/stuff.xml. Understand, this part works. Whenever I request the file, I get the expected result. But the file is big and I want to save bandwidth, so first I'd like to implement conditional GET semantics with the If-Modified-Since header. How do I do this? I've enabled mod_headers and mod_expired and added the <FilesMatching> section in my httpd.conf as recommended in countless examples I've seen online, but that didn't change the behavior when made a conditional GET request. I always get a status 200 with the entire document. So how the heck do I implement this? That'll cut down on neeless transfers. I'd also like to limit the amount of data transferred. Seeing as this is XML, gzipping it should save me 50% or more. My next step would be to somehow gzip the file and, if it's not too difficult, store it in memory. That'll cut down on per-access data transfer, and also reduce disk transfers. So how do I implement this type of caching? Thanks in advance.

    Read the article

< Previous Page | 566 567 568 569 570 571 572 573 574 575 576 577  | Next Page >