Search Results

Search found 62912 results on 2517 pages for 'data entry'.

Page 573/2517 | < Previous Page | 569 570 571 572 573 574 575 576 577 578 579 580  | Next Page >

  • Advice on designing web application with a 40+ year lifetime

    - by user2708395
    Scenario Currently, I am apart of a health care project whose main requirement is to capture data with unknown attributes using user generated forms by health care providers. The second requirement is that data integrity is key and that the application will be used for 40+ years. We are currently migrating the client's data from the past 40 years from various sources (Paper, Excel, Access, etc...) to the database. Future requirements are: Workflow management of forms Schedule management of forms Security/Role based management Reporting engine Mobile/Tablet support Situation Only 6 months in, the current (contracted) architect/senior programmer has taken the "fast" approach and has designed a poor system. The database is not normalized, the code is coupled, the tiers have no dedicated purpose and data is starting to go missing since he has designed some beans to perform "deletes" on the database. The code base is extremely bloated and there are jobs just to synchronize data since the database is not normalized. His approach has been to rely on backup jobs to restore missing data and doesn't seem to believe in re-factoring. Having presented my findings to the PM, the architect will be removed when his contract ends. I have been given the task to re-architect this application. My team consists of me and one junior programmer. We have no other resources. We have been granted a 6-month requirement freeze in which we can focus on re-building this system. I suggested using a CMS system like Drupal, but for policy reasons at the client's organization, the system must be built from scratch. This is the first time that I will be designing a system with a 40+ lifespan. I have only worked on projects with 3-5 year lifespans, so this situation is very new, yet exciting. Questions What design considerations will make the system more "future proof"? What experiences have you had in designing such systems - both failures and successes? What questions should be asked to the client/PM to make the system more "future proof"?

    Read the article

  • Caching by in-memory dictionaries. Are we doing it all wrong?

    - by user73983
    This approach is pretty much the accepted way to do anything in our company. A simple example : when a piece of data for a customer is requested from a service, we fetch all the data for that customer(relevant part to the service) and save it in a in-memory dictionary then serve it from there on following requests(we run singleton services). Any update goes to DB, then updates the in memory dictionary. It seems all simple and harmless but as we implement more complicated business rules the cache gets out of sync and we have to deal with hard to find bugs. Sometimes we defer writing to database, keeping new data in cache till then. There are cases when we store millions of rows in memory because the table has many relations to other tables and we need to show aggregate data quickly. All this cache handling is a big part of our codebase and I sense this is not the right way to do it. All of this juggling adds too much noise to the code and it makes it hard to understand the actual business logic. However I don't think we can serve data in a reasonable amount of time if we have to hit the database every time. I am unhappy about the current situation but I don't have a better alternative. My only solution would be to use NHibernate 2nd level cache but I have nearly no experience with it. I know many campanies use Redis or MemCached heavily to gain performance but I have no idea how I would integrate them into our system. I also don't know if they can perform better than in-memory data structures and queries. Are there any alternative approaches that I should look into?

    Read the article

  • FP for simulation and modelling

    - by heaptobesquare
    I'm about to start a simulation/modelling project. I already know that OOP is used for this kind of projects. However, studying Haskell made me consider using the FP paradigm for modelling a system of components. Let me elaborate: Let's say I have a component of type A, characterised by a set of data (a parameter like temperature or pressure,a PDE and some boundary conditions,etc.) and a component of type B, characterised by a different set of data(different or same parameter, different PDE and boundary conditions). Let's also assume that the functions/methods that are going to be applied on each component are the same (a Galerkin method for example). If I were to use an OOP approach, I would create two objects that would encapsulate each type's data, the methods for solving the PDE(inheritance would be used here for code reuse) and the solution to the PDE. On the other hand, if I were to use an FP approach, each component would be broken down to data parts and the functions that would act upon the data in order to get the solution for the PDE. This approach seems simpler to me assuming that linear operations on data would be trivial and that the parameters are constant. What if the parameters are not constant(for example, temperature increases suddenly and therefore cannot be immutable)? In OOP, the object's (mutable) state can be used. I know that Haskell has Monads for that. To conclude, would implementing the FP approach be actually simpler,less time consuming and easier to manage (add a different type of component or new method to solve the pde) compared to the OOP one? I come from a C++/Fortran background, plus I'm not a professional programmer, so correct me on anything that I've got wrong.

    Read the article

  • Domain model integration using JSON capable DTOs

    - by g-makulik
    I'm a bit confused about architectural choices for the java/web-applications world. The background is I have a system with certain hardware components (that introduce system immanent active behavior) and a configuration database for system meta and HW-components configuration data (these are even usually self contained, since the HW-components persist configuration data anyway). For realization of the configuration/status data exchange protocol with the HW-components we have chosen the Google Protobuf format, which works well for the directly wired communication with these components. Now we want to develop an abstract model (domain model) for those HW-components and I have the feeling that a plain Java class model would fit best for this (c++ implementation seems to have too much implementation/integration overhead with viable language-bridge interfaces). Google Protobuf message definitions could still serve well to describe DTO objects used to interact with a domain model API. But integrating Google Protobuf messages client side for e.g. data binding in the current view doesn't seem to be a good choice. I'm thinking about some extra serialization features, e.g. for JSON based data exchange with the views/controllers. Most lightweight solutions seem to involve a python based presentation layer using JSON based data transfer (I'm at least not sure to be fully informed about this). Is there some lightweight (applicable for a limited ARM Linux platform) framework available, supporting such architecture to realize a web-application?

    Read the article

  • What can I do in order to inform users of potential errors in my software in order to minimize liability?

    - by phobitor
    I'm an independent software developer that's spent the last few months creating software for viewing and searching map data. The software has some navigation functionality as well (mapping, directions,etc). The eventual goal is to sell it in mobile app markets. I use OpenStreetMap as my data source. I'm concerned about liability for erroneous map data / routing instructions, etc that might result when someone uses the application. There are a lot of stories on the internet where someone gets into an accident or gets stuck or gets lost because of their GPS unit/Google Maps/mapping app... I myself have come across incorrect map data as well in a GPS unit I have in my car. While I try to make my own software as bug free as possible, no software is truly bug free. And moving beyond what I can control, OpenStreetMap data (and street map data in general) is prone to errors as well. What steps can I take to clearly inform the user that results from the software aren't always perfect, and to minimize my liability?

    Read the article

  • The Oracle Enterprise Linux Software and Hardware Ecosystem

    - by sergio.leunissen
    It's been nearly four years since we launched the Unbreakable Linux support program and with it the free Oracle Enterprise Linux software. Since then, we've built up an extensive ecosystem of hardware and software partners. Oracle works directly with these vendors to ensure joint customers can run Oracle Enterprise Linux. As Oracle Enterprise Linux is fully--both source and binary--compatible with Red Hat Enterprise Linux (RHEL), there is minimal work involved for software and hardware vendors to test their products with it. We develop our software on Oracle Enterprise Linux and perform full certification testing on Oracle Enterprise Linux as well. Due to the compatibility between Oracle Enterprise Linux and RHEL, Oracle also certifies its software for use on RHEL, without any additional testing. Oracle Enterprise Linux tracks RHEL by publishing freely downloadable installation media on edelivery.oracle.com/linux and updates, bug fixes and security errata on Unbreakable Linux Network (ULN). At the same time, Oracle's Linux kernel team is shaping the future of enterprise Linux distributions by developing technologies and features that matter to customers who deploy Linux in the data center, including file systems, memory management, high performance computing, data integrity and virtualization. All this work is contributed to the Linux and Xen communities. The list below is a sample of the partners who have certified their products with Oracle Enterprise Linux. If you're interested in certifying your software or hardware with Oracle Enterprise Linux, please contact us via [email protected] Chip Manufacturers Intel, Intel Enabled Server Acceleration Alliance AMD Server vendors Cisco Unified Computing System Dawning Dell Egenera Fujitsu HP Huawei IBM NEC Sun/Oracle Storage Systems, Volume Management and File Systems 3Par Compellent EMC VPLEX FalconStor Fusion-io Hitachi Data Systems HP Storage Array Systems Lustre Network Appliance OCFS2 PillarData Symantec Veritas Storage Foundation Networking: Switches, Host Bus Adapters (HBAs), Converged Network Adapters (CNAs), InfiniBand Brocade Emulex Mellanox QLogic Voltaire SOA and Middleware ActiveState ActivePerl, ActivePython Tibco Zend Backup, Recovery & Replication Arkeia Network Backup Suite BakBone NetVault CommVault Simpana 8 EMC Networker, Replication Manager FalconStor Continuous Data Protector HP Data Protector NetApp Snapmanager Quest LiteSpeed Engine Steeleye Data Replication, Disaster Recovery Symantec NetBackup, Veritas Volume Replicator, Symantec Backup Exec Zmanda Amanda Enterprise Data Center Automation BMC CA Unicenter HP Server Automation (formerly Opsware), System Management Homepage Oracle Enterprise Manager Ops Center Quest Vizioncore vFoglight Pro TeamQuest Manager Clustering & High Availability FUJITSU x10sure NEC Express Cluster X Steeleye Lifekeeper Symantec Cluster Server Univa UniCluster Virtualization Platforms and Cloud Providers Amazon EC2 Citrix XenServer Rackspace Cloud VirtualBox VMWare ESX Security Management ArcSight: Enterprise Security Manager, Logger CA Access Control Centrify Suite Ecora Auditor FoxT Manager Likewise: Unix Account Management Lumension Endpoint Management and Security Suite QualysGuard Suite Quest Privilege Manager McAfee Application Control, Change ControlIntegrity Monitor, Integrity Control, PCI Pro Solidcore S3 Symantec Enterprise Security Manager (ESM) Tripwire Trusted Computer Solutions

    Read the article

  • Configuring UCM cache to check for external Content Server changes

    - by Martin Deh
    Recently, I was involved in a customer scenario where they were modifying the Content Server's contributor data files directly through Content Server.  This operation of course is completely supported.  However, since the contributor data file was modified through the "backdoor", a running WebCenter Spaces page, which also used the same data file, would not get the updates immediately.  This was due to two reasons.  The first reason is that the Spaces page was using Content Presenter to display the contents of the data file. The second reason is that the Spaces application was using the "cached" version of the data file.  Fortunately, there is a way to configure cache so backdoor changes can be picked up more quickly and automatically. First a brief overview of Content Presenter.  The Content Presenter task flow enables WebCenter Spaces users with Page-Edit permissions to precisely customize the selection and presentation of content in a WebCenter Spaces application.  With Content Presenter, you can select a single item of content, contents under a folder, a list of items, or query for content, and then select a Content Presenter based template to render the content on a page in a Spaces application.  In addition to displaying the folders and the files in a Content Server, Content Presenter integrates with Oracle Site Studio to allow you to create, access, edit, and display Site Studio contributor data files (Content Server Document) in either a Site Studio region template or in a custom Content Presenter display template.  More information about creating Content Presenter Display Template can be found in the OFM Developers Guide for WebCenter Portal. The easiest way to configure the cache is to modify the WebCenter Spaces Content Server service connection setting through Enterprise Manager.  From here, under the Cache Details, there is a section to set the Cache Invalidation Interval.  Basically, this enables the cache to be monitored by the cache "sweeper" utility.  The cache sweeper queries for changes in the Content Server, and then "marks" the object in cache as "dirty".  This causes the application in turn to get a new copy of the document from the Content Server that replaces the cached version.  By default the initial value for the Cache Invalidation Interval is set to 0 (minutes).  This basically means that the sweeper is OFF.  To turn the sweeper ON, just set a value (in minutes).  The mininal value that can be set is 2 (minutes): Just a note.  In some instances, once the value of the Cache Invalidation Interval has been set (and saved) in the Enterprise Manager UI, it becomes "sticky" and the interval value cannot be set back to 0.  The good news is that this value can also be updated throught a WLST command.   The WLST command to run is as follows: setJCRContentServerConnection(appName, name, [socketType, url, serverHost, serverPort, keystoreLocation, keystorePassword, privateKeyAlias, privateKeyPassword, webContextRoot, clientSecurityPolicy, cacheInvalidationInterval, binaryCacheMaxEntrySize, adminUsername, adminPassword, extAppId, timeout, isPrimary, server, applicationVersion]) One way to get the required information for executing the command is to use the listJCRContentServerConnections('webcenter',verbose=true) command.  For example, this is the sample output from the execution: ------------------ UCM ------------------ Connection Name: UCM Connection Type: JCR External Appliction ID: Timeout: (not set) CIS Socket Type: socket CIS Server Hostname: webcenter.oracle.local CIS Server Port: 4444 CIS Keystore Location: CIS Private Key Alias: CIS Web URL: Web Server Context Root: /cs Client Security Policy: Admin User Name: sysadmin Cache Invalidation Interval: 2 Binary Cache Maximum Entry Size: 1024 The Documents primary connection is "UCM" From this information, the completed  setJCRContentServerConnection would be: setJCRContentServerConnection(appName='webcenter',name='UCM', socketType='socket', serverHost='webcenter.oracle.local', serverPort='4444', webContextRoot='/cs', cacheInvalidationInterval='0', binaryCacheMaxEntrySize='1024',adminUsername='sysadmin',isPrimary=1) Note: The Spaces managed server must be restarted for the change to take effect. More information about using WLST for WebCenter can be found here. Once the sweeper is turned ON, only cache objects that have been changed will be invalidated.  To test this out, I will go through a simple scenario.  The first thing to do is configure the Content Server so it can monitor and report on events.  Log into the Content Server console application, and under the Administration menu item, select System Audit Information.  Note: If your console is using the left menu display option, the Administration link will be located there. Under the Tracing Sections Information, add in only "system" and "requestaudit" in the Active Sections.  Check Full Verbose Tracing, check Save, then click the Update button.  Once this is done, select the View Server Output menu option.  This will change the browser view to display the log.  This is all that is needed to configure the Content Server. For example, the following is the View Server Output with the cache invalidation interval set to 2(minutes) Note the time stamp: requestaudit/6 08.30 09:52:26.001  IdcServer-68    GET_FOLDER_HISTORY_REPORT [dUser=sysadmin][IsJava=1] 0.016933999955654144(secs) requestaudit/6 08.30 09:52:26.010  IdcServer-69    GET_FOLDER_HISTORY_REPORT [dUser=sysadmin][IsJava=1] 0.006134999915957451(secs) requestaudit/6 08.30 09:52:26.014  IdcServer-70    GET_DOCUMENT_HISTORY_REPORT [dUser=sysadmin][IsJava=1] 0.004271999932825565(secs) ... other trace info ... requestaudit/6 08.30 09:54:26.002  IdcServer-71    GET_FOLDER_HISTORY_REPORT [dUser=sysadmin][IsJava=1] 0.020323999226093292(secs) requestaudit/6 08.30 09:54:26.011  IdcServer-72    GET_FOLDER_HISTORY_REPORT [dUser=sysadmin][IsJava=1] 0.017928000539541245(secs) requestaudit/6 08.30 09:54:26.017  IdcServer-73    GET_DOCUMENT_HISTORY_REPORT [dUser=sysadmin][IsJava=1] 0.010185999795794487(secs) Now that the tracing logs are reporting correctly, the next step is set up the Spaces app to test the sweeper. I will use 2 different pages that will use Content Presenter task flows.  Each task flow will use a different custom Content Presenter display template, and will be assign 2 different contributor data files (document that will be in the cache).  The pages at run time appear as follows: Initially, when the Space pages containing the content is loaded in the browser for the first time, you can see the tracing information in the Content Server output viewer. requestaudit/6 08.30 11:51:12.030 IdcServer-129 CLEAR_SERVER_OUTPUT [dUser=weblogic] 0.029171999543905258(secs) requestaudit/6 08.30 11:51:12.101 IdcServer-130 GET_SERVER_OUTPUT [dUser=weblogic] 0.025721000507473946(secs) requestaudit/6 08.30 11:51:26.592 IdcServer-131 VCR_GET_DOCUMENT_BY_NAME [dID=919][dDocName=DF_UCMCACHETESTER][dDocTitle=DF_UCMCacheTester][dUser=weblogic][RevisionSelectionMethod=LatestReleased][IsJava=1] 0.21525299549102783(secs) requestaudit/6 08.30 11:51:27.117 IdcServer-132 VCR_GET_CONTENT_TYPES [dUser=sysadmin][IsJava=1] 0.5059549808502197(secs) requestaudit/6 08.30 11:51:27.146 IdcServer-133 VCR_GET_CONTENT_TYPE [dUser=sysadmin][IsJava=1] 0.03360399976372719(secs) requestaudit/6 08.30 11:51:27.169 IdcServer-134 VCR_GET_CONTENT_TYPE [dUser=sysadmin][IsJava=1] 0.008806000463664532(secs) requestaudit/6 08.30 11:51:27.204 IdcServer-135 VCR_GET_CONTENT_TYPE [dUser=sysadmin][IsJava=1] 0.013265999965369701(secs) requestaudit/6 08.30 11:51:27.384 IdcServer-136 VCR_GET_CONTENT_TYPE [dUser=sysadmin][IsJava=1] 0.18119299411773682(secs) requestaudit/6 08.30 11:51:27.533 IdcServer-137 VCR_GET_CONTENT_TYPE [dUser=sysadmin][IsJava=1] 0.1519480049610138(secs) requestaudit/6 08.30 11:51:27.634 IdcServer-138 VCR_GET_CONTENT_TYPE [dUser=sysadmin][IsJava=1] 0.10827399790287018(secs) requestaudit/6 08.30 11:51:27.687 IdcServer-139 VCR_GET_CONTENT_TYPE [dUser=sysadmin][IsJava=1] 0.059702999889850616(secs) requestaudit/6 08.30 11:51:28.271 IdcServer-140 GET_USER_PERMISSIONS [dUser=weblogic][IsJava=1] 0.006703000050038099(secs) requestaudit/6 08.30 11:51:28.285 IdcServer-141 GET_ENVIRONMENT [dUser=sysadmin][IsJava=1] 0.010893999598920345(secs) requestaudit/6 08.30 11:51:30.433 IdcServer-142 GET_SERVER_OUTPUT [dUser=weblogic] 0.017318999394774437(secs) requestaudit/6 08.30 11:51:41.837 IdcServer-143 VCR_GET_DOCUMENT_BY_NAME [dID=508][dDocName=113_ES][dDocTitle=Landing Home][dUser=weblogic][RevisionSelectionMethod=LatestReleased][IsJava=1] 0.15937699377536774(secs) requestaudit/6 08.30 11:51:42.781 IdcServer-144 GET_FILE [dID=326][dDocName=WEBCENTERORACL000315][dDocTitle=Duke][dUser=anonymous][RevisionSelectionMethod=LatestReleased][dSecurityGroup=Public][xCollectionID=0] 0.16288499534130096(secs) The highlighted sections show where the 2 data files DF_UCMCACHETESTER (P1 page) and 113_ES (P2 page) were called by the (Spaces) VCR connection to the Content Server. The most important line to notice is the VCR_GET_DOCUMENT_BY_NAME invocation.  On subsequent refreshes of these 2 pages, you will notice (after you refresh the Content Server's View Server Output) that there are no further traces of the same VCR_GET_DOCUMENT_BY_NAME invocations.  This is because the pages are getting the documents from the cache. The next step is to go through the "backdoor" and change one of the documents through the Content Server console.  This operation can be done by first locating the data file document, and from the Content Information page, select Edit Data File menu option.   This invokes the Site Studio Contributor, where the modifications can be made. Refreshing the Content Server View Server Output, the tracing displays the operations perform on the document.  requestaudit/6 08.30 11:56:59.972 IdcServer-255 SS_CHECKOUT_BY_NAME [dID=922][dDocName=DF_UCMCACHETESTER][dUser=weblogic][dSecurityGroup=Public] 0.05558200180530548(secs) requestaudit/6 08.30 11:57:00.065 IdcServer-256 SS_GET_CONTRIBUTOR_CONFIG [dID=922][dDocName=DF_UCMCACHETESTER][dDocTitle=DF_UCMCacheTester][dUser=weblogic][dSecurityGroup=Public][xCollectionID=0] 0.08632399886846542(secs) requestaudit/6 08.30 11:57:00.470 IdcServer-259 DOC_INFO_BY_NAME [dID=922][dDocName=DF_UCMCACHETESTER][dDocTitle=DF_UCMCacheTester][dUser=weblogic][dSecurityGroup=Public][xCollectionID=0] 0.02268899977207184(secs) requestaudit/6 08.30 11:57:10.177 IdcServer-264 GET_FOLDER_HISTORY_REPORT [dUser=sysadmin][IsJava=1] 0.007652000058442354(secs) requestaudit/6 08.30 11:57:10.181 IdcServer-263 GET_FOLDER_HISTORY_REPORT [dUser=sysadmin][IsJava=1] 0.01868399977684021(secs) requestaudit/6 08.30 11:57:10.187 IdcServer-265 GET_DOCUMENT_HISTORY_REPORT [dUser=sysadmin][IsJava=1] 0.009367000311613083(secs) (internal)/6 08.30 11:57:26.118 IdcServer-266 File to be removed: /oracle/app/admin/domains/webcenter/ucm/cs/vault/~temp/703253295.xml (internal)/6 08.30 11:57:26.121 IdcServer-266 File to be removed: /oracle/app/admin/domains/webcenter/ucm/cs/vault/~temp/703253295.xml requestaudit/6 08.30 11:57:26.122 IdcServer-266 SS_SET_ELEMENT_DATA [dID=923][dDocName=DF_UCMCACHETESTER][dDocTitle=DF_UCMCacheTester][dUser=weblogic][dSecurityGroup=Public][xCollectionID=0][StatusCode=0][StatusMessage=Successfully checked in content item 'DF_UCMCACHETESTER'.] 0.3765290081501007(secs) requestaudit/6 08.30 11:57:30.710 IdcServer-267 DOC_INFO_BY_NAME [dID=923][dDocName=DF_UCMCACHETESTER][dDocTitle=DF_UCMCacheTester][dUser=weblogic][dSecurityGroup=Public][xCollectionID=0] 0.07942699640989304(secs) requestaudit/6 08.30 11:57:30.733 IdcServer-268 SS_GET_CONTRIBUTOR_STRINGS [dUser=weblogic] 0.0044570001773536205(secs) After a few moments and refreshing the P1 page, the updates has been applied. Note: The refresh time may very, since the Cache Invalidation Interval (set to 2 minutes) is not determined by when changes happened.  The sweeper just runs every 2 minutes. Refreshing the Content Server View Server Output, the tracing displays the important information. requestaudit/6 08.30 11:59:10.171 IdcServer-270 GET_FOLDER_HISTORY_REPORT [dUser=sysadmin][IsJava=1] 0.00952600035816431(secs) requestaudit/6 08.30 11:59:10.179 IdcServer-271 GET_FOLDER_HISTORY_REPORT [dUser=sysadmin][IsJava=1] 0.011118999682366848(secs) requestaudit/6 08.30 11:59:10.182 IdcServer-272 GET_DOCUMENT_HISTORY_REPORT [dUser=sysadmin][IsJava=1] 0.007447000127285719(secs) requestaudit/6 08.30 11:59:16.885 IdcServer-273 VCR_GET_DOCUMENT_BY_NAME [dID=923][dDocName=DF_UCMCACHETESTER][dDocTitle=DF_UCMCacheTester][dUser=weblogic][RevisionSelectionMethod=LatestReleased][IsJava=1] 0.0786449983716011(secs) After the specifed interval time the sweeper is invoked, which is noted by the GET_ ... calls.  Since the history has noted the change, the next call is to the VCR_GET_DOCUMENT_BY_NAME to retrieve the new version of the (modifed) data file.  Navigating back to the P2 page, and viewing the server output, there are no further VCR_GET_DOCUMENT_BY_NAME to retrieve the data file.  This simply means that this data file was just retrieved from the cache.   Upon further review of the server output, we can see that there was only 1 request for the VCR_GET_DOCUMENT_BY_NAME: requestaudit/6 08.30 12:08:00.021 Audit Request Monitor Request Audit Report over the last 120 Seconds for server webcenteroraclelocal16200****  requestaudit/6 08.30 12:08:00.021 Audit Request Monitor -Num Requests 8 Errors 0 Reqs/sec. 0.06666944175958633 Avg. Latency (secs) 0.02762500010430813 Max Thread Count 2  requestaudit/6 08.30 12:08:00.021 Audit Request Monitor 1 Service VCR_GET_DOCUMENT_BY_NAME Total Elapsed Time (secs) 0.09200000017881393 Num requests 1 Num errors 0 Avg. Latency (secs) 0.09200000017881393  requestaudit/6 08.30 12:08:00.021 Audit Request Monitor 2 Service GET_PERSONALIZED_JAVASCRIPT Total Elapsed Time (secs) 0.054999999701976776 Num requests 1 Num errors 0 Avg. Latency (secs) 0.054999999701976776  requestaudit/6 08.30 12:08:00.021 Audit Request Monitor 3 Service GET_FOLDER_HISTORY_REPORT Total Elapsed Time (secs) 0.028999999165534973 Num requests 2 Num errors 0 Avg. Latency (secs) 0.014499999582767487  requestaudit/6 08.30 12:08:00.021 Audit Request Monitor 4 Service GET_SERVER_OUTPUT Total Elapsed Time (secs) 0.017999999225139618 Num requests 1 Num errors 0 Avg. Latency (secs) 0.017999999225139618  requestaudit/6 08.30 12:08:00.021 Audit Request Monitor 5 Service GET_FILE Total Elapsed Time (secs) 0.013000000268220901 Num requests 1 Num errors 0 Avg. Latency (secs) 0.013000000268220901  requestaudit/6 08.30 12:08:00.021 Audit Request Monitor ****End Audit Report*****  

    Read the article

  • SQL SERVER – Securing TRUNCATE Permissions in SQL Server

    - by pinaldave
    Download the Script of this article from here. On December 11, 2010, Vinod Kumar, a Databases & BI technology evangelist from Microsoft Corporation, graced Ahmedabad by spending some time with the Community during the Community Tech Days (CTD) event. As he was running through a few demos, Vinod asked the audience one of the most fundamental and common interview questions – “What is the difference between a DELETE and TRUNCATE?“ Ahmedabad SQL Server User Group Expert Nakul Vachhrajani has come up with excellent solutions of the same. I must congratulate Nakul for this excellent solution and as a encouragement to User Group member, I am publishing the same article over here. Nakul Vachhrajani is a Software Specialist and systems development professional with Patni Computer Systems Limited. He has functional experience spanning legacy code deprecation, system design, documentation, development, implementation, testing, maintenance and support of complex systems, providing business intelligence solutions, database administration, performance tuning, optimization, product management, release engineering, process definition and implementation. He has comprehensive grasp on Database Administration, Development and Implementation with MS SQL Server and C, C++, Visual C++/C#. He has about 6 years of total experience in information technology. Nakul is an member of the Ahmedabad and Gandhinagar SQL Server User Groups, and actively contributes to the community by actively participating in multiple forums and websites like SQLAuthority.com, BeyondRelational.com, SQLServerCentral.com and many others. Please note: The opinions expressed herein are Nakul own personal opinions and do not represent his employer’s view in anyway. All data from everywhere here on Earth go through a series of  four distinct operations, identified by the words: CREATE, READ, UPDATE and DELETE, or simply, CRUD. Putting in Microsoft SQL Server terms, is the process goes like this: INSERT, SELECT, UPDATE and DELETE/TRUNCATE. Quite a few interesting responses were received and evaluated live during the session. To summarize them, the most important similarity that came out was that both DELETE and TRUNCATE participate in transactions. The major differences (not all) that came out of the exercise were: DELETE: DELETE supports a WHERE clause DELETE removes rows from a table, row-by-row Because DELETE moves row-by-row, it acquires a row-level lock Depending upon the recovery model of the database, DELETE is a fully-logged operation. Because DELETE moves row-by-row, it can fire off triggers TRUNCATE: TRUNCATE does not support a WHERE clause TRUNCATE works by directly removing the individual data pages of a table TRUNCATE directly occupies a table-level lock. (Because a lock is acquired, and because TRUNCATE can also participate in a transaction, it has to be a logged operation) TRUNCATE is, therefore, a minimally-logged operation; again, this depends upon the recovery model of the database Triggers are not fired when TRUNCATE is used (because individual row deletions are not logged) Finally, Vinod popped the big homework question that must be critically analyzed: “We know that we can restrict a DELETE operation to a particular user, but how can we restrict the TRUNCATE operation to a particular user?” After returning home and having a nice cup of coffee, I noticed that my gray cells immediately started to work. Below was the result of my research. As what is always said, the devil is in the details. Upon looking at the Permissions section for the TRUNCATE statement in Books On Line, the following jumps right out: “The minimum permission required is ALTER on table_name. TRUNCATE TABLE permissions default to the table owner, members of the sysadmin fixed server role, and the db_owner and db_ddladmin fixed database roles, and are not transferable. However, you can incorporate the TRUNCATE TABLE statement within a module, such as a stored procedure, and grant appropriate permissions to the module using the EXECUTE AS clause.“ Now, what does this mean? Unlike DELETE, one cannot directly assign permissions to a user/set of users allowing or revoking TRUNCATE rights. However, there is a way to circumvent this. It is important to recall that in Microsoft SQL Server, database engine security surrounds the concept of a “securable”, which is any object like a table, stored procedure, trigger, etc. Rights are assigned to a principal on a securable. Refer to the image below (taken from the SQL Server Books On Line). urable”, which is any object like a table, stored procedure, trigger, etc. Rights are assigned to a principal on a securable. Refer to the image below (taken from the SQL Server Books On Line). SETTING UP THE ENVIRONMENT – (01A_Truncate Table Permissions.sql) Script Provided at the end of the article. By the end of this demo, one will be able to do all the CRUD operations, except the TRUNCATE, and the other will only be able to execute the TRUNCATE. All you will need for this test is any edition of SQL Server 2008. (With minor changes, these scripts can be made to work with SQL 2005.) We begin by creating the following: 1.       A test database 2.        Two database roles: associated logins and users 3.       Switch over to the test database and create a test table. Then, add some data into it. I am using row constructors, which is new to SQL 2008. Creating the modules that will be used to enforce permissions 1.       We have already created one of the modules that we will be assigning permissions to. That module is the table: TruncatePermissionsTest 2.       We will now create two stored procedures; one is for the DELETE operation and the other for the TRUNCATE operation. Please note that for all practical purposes, the end result is the same – all data from the table TruncatePermissionsTest is removed Assigning the permissions Now comes the most important part of the demonstration – assigning permissions. A permissions matrix can be worked out as under: To apply the security rights, we use the GRANT and DENY clauses, as under: That’s it! We are now ready for our big test! THE TEST (01B_Truncate Table Test Queries.sql) Script Provided at the end of the article. I will now need two separate SSMS connections, one with the login AllowedTruncate and the other with the login RestrictedTruncate. Running the test is simple; all that’s required is to run through the script – 01B_Truncate Table Test Queries.sql. What I will demonstrate here via screen-shots is the behavior of SQL Server when logged in as the AllowedTruncate user. There are a few other combinations than what are highlighted here. I will leave the reader the right to explore the behavior of the RestrictedTruncate user and these additional scenarios, as a form of self-study. 1.       Testing SELECT permissions 2.       Testing TRUNCATE permissions (Remember, “deny by default”?) 3.       Trying to circumvent security by trying to TRUNCATE the table using the stored procedure Hence, we have now proved that a user can indeed be assigned permissions to specifically assign TRUNCATE permissions. I also hope that the above has sparked curiosity towards putting some security around the probably “destructive” operations of DELETE and TRUNCATE. I would like to wish each and every one of the readers a very happy and secure time with Microsoft SQL Server. (Please find the scripts – 01A_Truncate Table Permissions.sql and 01B_Truncate Table Test Queries.sql that have been used in this demonstration. Please note that these scripts contain purely test-level code only. These scripts must not, at any cost, be used in the reader’s production environments). 01A_Truncate Table Permissions.sql /* ***************************************************************************************************************** Developed By          : Nakul Vachhrajani Functionality         : This demo is focused on how to allow only TRUNCATE permissions to a particular user How to Use            : 1. Run through, step-by-step through the sequence till Step 08 to create a test database 2. Switch over to the "Truncate Table Test Queries.sql" and execute it step-by-step in two different SSMS windows, one where you have logged in as 'RestrictedTruncate', and the other as 'AllowedTruncate' 3. Come back to "Truncate Table Permissions.sql" 4. Execute Step 10 to cleanup! Modifications         : December 13, 2010 - NAV - Updated to add a security matrix and improve code readability when applying security December 12, 2010 - NAV - Created ***************************************************************************************************************** */ -- Step 01: Create a new test database CREATE DATABASE TruncateTestDB GO USE TruncateTestDB GO -- Step 02: Add roles and users to demonstrate the security of the Truncate operation -- 2a. Create the new roles CREATE ROLE AllowedTruncateRole; GO CREATE ROLE RestrictedTruncateRole; GO -- 2b. Create new logins CREATE LOGIN AllowedTruncate WITH PASSWORD = 'truncate@2010', CHECK_POLICY = ON GO CREATE LOGIN RestrictedTruncate WITH PASSWORD = 'truncate@2010', CHECK_POLICY = ON GO -- 2c. Create new Users using the roles and logins created aboave CREATE USER TruncateUser FOR LOGIN AllowedTruncate WITH DEFAULT_SCHEMA = dbo GO CREATE USER NoTruncateUser FOR LOGIN RestrictedTruncate WITH DEFAULT_SCHEMA = dbo GO -- 2d. Add the newly created login to the newly created role sp_addrolemember 'AllowedTruncateRole','TruncateUser' GO sp_addrolemember 'RestrictedTruncateRole','NoTruncateUser' GO -- Step 03: Change over to the test database USE TruncateTestDB GO -- Step 04: Create a test table within the test databse CREATE TABLE TruncatePermissionsTest (Id INT IDENTITY(1,1), Name NVARCHAR(50)) GO -- Step 05: Populate the required data INSERT INTO TruncatePermissionsTest VALUES (N'Delhi'), (N'Mumbai'), (N'Ahmedabad') GO -- Step 06: Encapsulate the DELETE within another module CREATE PROCEDURE proc_DeleteMyTable WITH EXECUTE AS SELF AS DELETE FROM TruncateTestDB..TruncatePermissionsTest GO -- Step 07: Encapsulate the TRUNCATE within another module CREATE PROCEDURE proc_TruncateMyTable WITH EXECUTE AS SELF AS TRUNCATE TABLE TruncateTestDB..TruncatePermissionsTest GO -- Step 08: Apply Security /* *****************************SECURITY MATRIX*************************************** =================================================================================== Object                   | Permissions |                 Login |             | AllowedTruncate   |   RestrictedTruncate |             |User:NoTruncateUser|   User:TruncateUser =================================================================================== TruncatePermissionsTest  | SELECT,     |      GRANT        |      (Default) | INSERT,     |                   | | UPDATE,     |                   | | DELETE      |                   | -------------------------+-------------+-------------------+----------------------- TruncatePermissionsTest  | ALTER       |      DENY         |      (Default) -------------------------+-------------+----*/----------------+----------------------- proc_DeleteMyTable | EXECUTE | GRANT | DENY -------------------------+-------------+-------------------+----------------------- proc_TruncateMyTable | EXECUTE | DENY | GRANT -------------------------+-------------+-------------------+----------------------- *****************************SECURITY MATRIX*************************************** */ /* Table: TruncatePermissionsTest*/ GRANT SELECT, INSERT, UPDATE, DELETE ON TruncateTestDB..TruncatePermissionsTest TO NoTruncateUser GO DENY ALTER ON TruncateTestDB..TruncatePermissionsTest TO NoTruncateUser GO /* Procedure: proc_DeleteMyTable*/ GRANT EXECUTE ON TruncateTestDB..proc_DeleteMyTable TO NoTruncateUser GO DENY EXECUTE ON TruncateTestDB..proc_DeleteMyTable TO TruncateUser GO /* Procedure: proc_TruncateMyTable*/ DENY EXECUTE ON TruncateTestDB..proc_TruncateMyTable TO NoTruncateUser GO GRANT EXECUTE ON TruncateTestDB..proc_TruncateMyTable TO TruncateUser GO -- Step 09: Test --Switch over to the "Truncate Table Test Queries.sql" and execute it step-by-step in two different SSMS windows: --    1. one where you have logged in as 'RestrictedTruncate', and --    2. the other as 'AllowedTruncate' -- Step 10: Cleanup sp_droprolemember 'AllowedTruncateRole','TruncateUser' GO sp_droprolemember 'RestrictedTruncateRole','NoTruncateUser' GO DROP USER TruncateUser GO DROP USER NoTruncateUser GO DROP LOGIN AllowedTruncate GO DROP LOGIN RestrictedTruncate GO DROP ROLE AllowedTruncateRole GO DROP ROLE RestrictedTruncateRole GO USE MASTER GO DROP DATABASE TruncateTestDB GO 01B_Truncate Table Test Queries.sql /* ***************************************************************************************************************** Developed By          : Nakul Vachhrajani Functionality         : This demo is focused on how to allow only TRUNCATE permissions to a particular user How to Use            : 1. Switch over to this from "Truncate Table Permissions.sql", Step #09 2. Execute this step-by-step in two different SSMS windows a. One where you have logged in as 'RestrictedTruncate', and b. The other as 'AllowedTruncate' 3. Return back to "Truncate Table Permissions.sql" 4. Execute Step 10 to cleanup! Modifications         : December 12, 2010 - NAV - Created ***************************************************************************************************************** */ -- Step 09A: Switch to the test database USE TruncateTestDB GO -- Step 09B: Ensure that we have valid data SELECT * FROM TruncatePermissionsTest GO -- (Expected: Following error will occur if logged in as "AllowedTruncate") -- Msg 229, Level 14, State 5, Line 1 -- The SELECT permission was denied on the object 'TruncatePermissionsTest', database 'TruncateTestDB', schema 'dbo'. --Step 09C: Attempt to Truncate Data from the table without using the stored procedure TRUNCATE TABLE TruncatePermissionsTest GO -- (Expected: Following error will occur) --  Msg 1088, Level 16, State 7, Line 2 --  Cannot find the object "TruncatePermissionsTest" because it does not exist or you do not have permissions. -- Step 09D:Regenerate Test Data INSERT INTO TruncatePermissionsTest VALUES (N'London'), (N'Paris'), (N'Berlin') GO -- (Expected: Following error will occur if logged in as "AllowedTruncate") -- Msg 229, Level 14, State 5, Line 1 -- The INSERT permission was denied on the object 'TruncatePermissionsTest', database 'TruncateTestDB', schema 'dbo'. --Step 09E: Attempt to Truncate Data from the table using the stored procedure EXEC proc_TruncateMyTable GO -- (Expected: Will execute successfully with 'AllowedTruncate' user, will error out as under with 'RestrictedTruncate') -- Msg 229, Level 14, State 5, Procedure proc_TruncateMyTable, Line 1 -- The EXECUTE permission was denied on the object 'proc_TruncateMyTable', database 'TruncateTestDB', schema 'dbo'. -- Step 09F:Regenerate Test Data INSERT INTO TruncatePermissionsTest VALUES (N'Madrid'), (N'Rome'), (N'Athens') GO --Step 09G: Attempt to Delete Data from the table without using the stored procedure DELETE FROM TruncatePermissionsTest GO -- (Expected: Following error will occur if logged in as "AllowedTruncate") -- Msg 229, Level 14, State 5, Line 2 -- The DELETE permission was denied on the object 'TruncatePermissionsTest', database 'TruncateTestDB', schema 'dbo'. -- Step 09H:Regenerate Test Data INSERT INTO TruncatePermissionsTest VALUES (N'Spain'), (N'Italy'), (N'Greece') GO --Step 09I: Attempt to Delete Data from the table using the stored procedure EXEC proc_DeleteMyTable GO -- (Expected: Following error will occur if logged in as "AllowedTruncate") -- Msg 229, Level 14, State 5, Procedure proc_DeleteMyTable, Line 1 -- The EXECUTE permission was denied on the object 'proc_DeleteMyTable', database 'TruncateTestDB', schema 'dbo'. --Step 09J: Close this SSMS window and return back to "Truncate Table Permissions.sql" Thank you Nakul to take up the challenge and prove that Ahmedabad and Gandhinagar SQL Server User Group has talent to solve difficult problems. Reference: Pinal Dave (http://blog.SQLAuthority.com) Filed under: Best Practices, Pinal Dave, Readers Contribution, Readers Question, SQL, SQL Authority, SQL Query, SQL Scripts, SQL Security, SQL Server, SQL Tips and Tricks, T SQL, Technology

    Read the article

  • SQL Server Editions and Integration Services

    The SQL Server 2005 and SQL Server 2008 product family has quite a few editions now, so what does this mean for SQL Server Integration Services? Starting from the bottom we have the free edition known as Express, and the entry level Workgroup edition, as well as the new Web edition. None of these three include the full SSIS product, but they do all include the SQL Server Import and Export Wizard, with access to basic data sources but nothing more, so for simple loading and extraction of data this should suffice. You will not be able to build packages though, this is just a one shot deal aimed at using the wizard on an ad-hoc basis. To get the full power of Integration Services you need to start with Standard edition. This includes the BI Development Studio, for building your own packages, and fully functional IDE integrated into Visual Studio. (You get the full VS 2005/2008 IDE with the product). All core functions will be available but with a restricted set of transformations and tasks. The SQL Server 2005 Features Comparison or Features Supported by the Editions of SQL Server 2008 describes standard edition as having basic transforms, compared to Enterprise which includes the advanced transforms. I think basic is a little harsh considering the power you get with Standard, but the advanced covers the truly ground-breaking capabilities of data mining, text mining and cleansing or fuzzy transforms. The power of performing these operations within your ETL pipeline should not be underestimated, but not all processes will require these capabilities, so it seems like a reasonable delineation. Thankfully there are no feature limitations or artificial governors within Standard compared to Enterprise. The same control flow and data flow engines underpin both editions, with the same configuration and deployment options allowing you to work seamlessly between environments and editions if using the common components. In fact there are no govenors at all in SSIS, so whilst the SQL Database engine is limited to 4 CPUs in Standard edition, SSIS is only limited by the base operating system. The advanced transforms only available with Enterprise edition: Data Mining Training Destination Data Mining Query Component Fuzzy Grouping Fuzzy Lookup Term Extraction Term Lookup Dimension Processing Destination Partition Processing Destination The advanced tasks only available with Enterprise edition: Data Mining Query Task So in summary, if you want SQL Server Integration Services, you need SQL Server Standard edition, and for the more advanced tasks and transforms you need SQL Server Enterprise edition. To recap, the answer to the often asked question is no, SQL Server Integration Services is not available in SQL Server Express or Workgroup editions.

    Read the article

  • Building an HTML5 App with ASP.NET

    - by Stephen Walther
    I’m teaching several JavaScript and ASP.NET workshops over the next couple of months (thanks everyone!) and I thought it would be useful for my students to have a really easy to use JavaScript reference. I wanted a simple interactive JavaScript reference and I could not find one so I decided to put together one of my own. I decided to use the latest features of JavaScript, HTML5 and jQuery such as local storage, offline manifests, and jQuery templates. What could be more appropriate than building a JavaScript Reference with JavaScript? You can try out the application by visiting: http://Superexpert.com/JavaScriptReference Because the app takes advantage of several advanced features of HTML5, it won’t work with Internet Explorer 6 (but really, you should stop using that browser). I have tested it with IE 8, Chrome 8, Firefox 3.6, and Safari 5. You can download the source for the JavaScript Reference application at the end of this article. Superexpert JavaScript Reference Let me provide you with a brief walkthrough of the app. When you first open the application, you see the following lookup screen: As you type the name of something from the JavaScript language, matching results are displayed: You can click the details link for any entry to view details for an entry in a modal dialog: Alternatively, you can click on any of the tabs -- Objects, Functions, Properties, Statements, Operators, Comments, or Directives -- to filter results by type of syntax. For example, you might want to see a list of all JavaScript built-in objects: You can login to the application to make modification to the application: After you login, you can add, update, or delete entries in the reference database: HTML5 Local Storage The application takes advantage of HTML5 local storage to store all of the reference entries on the local browser. IE 8, Chrome 8, Firefox 3.6, and Safari 5 all support local storage. When you open the application for the first time, all of the reference entries are transferred to the browser. The data is stored persistently. Even if you shutdown your computer and return to the application many days later, the data does not need to be transferred again. Whenever you open the application, the app checks with the server to see if any of the entries have been updated on the server. If there have been updates, then only the updates are transferred to the browser and the updates are merged with the existing entries in local storage. After the reference database has been transferred to your browser once, only changes are transferred in the future. You get two benefits from using local storage. First, the application loads very fast and works very fast after the data has been loaded once. The application does not query the server whenever you filter or view entries. All of the data is persisted in the browser. Second, you can browse the JavaScript reference even when you are not connected to the Internet (when you are on the proverbial airplane). The JavaScript Reference works as an offline application for browsers that support offline applications (unfortunately, not IE). When using Google Chrome, you can easily view the contents of local storage by selecting Tools, Developer Tools (CTRL-SHIFT I) and selecting Storage, Local Storage: The JavaScript Reference app stores two items in local storage: entriesLastUpdated and entries. HTML5 Offline App For browsers that support HTML5 offline applications – Chrome 8 and Firefox 3.6 but not Internet Explorer – you do not need to be connected to the Internet to use the JavaScript Reference. The JavaScript Reference can execute entirely on your machine just like any other desktop application. When you first open the application with Firefox, you are presented with the following warning: Notice the notification bar that asks whether you want to accept offline content. If you click the Allow button then all of the files (generated ASPX, images, CSS, JavaScript) needed for the JavaScript Reference will be stored on your local computer. Automatic Script Minification and Combination All of the custom JavaScript files are combined and minified automatically whenever the application is built with Visual Studio. All of the custom scripts are contained in a folder named App_Scripts: When you perform a build, the combine.js and combine.debug.js files are generated. The Combine.config file contains the list of files that should be combined (importantly, it specifies the order in which the files should be combined). Here’s the contents of the Combine.config file:   <?xml version="1.0"?> <combine> <scripts> <file path="compat.js" /> <file path="storage.js" /> <file path="serverData.js" /> <file path="entriesHelper.js" /> <file path="authentication.js" /> <file path="default.js" /> </scripts> </combine>   jQuery and jQuery UI The JavaScript Reference application takes heavy advantage of jQuery and jQuery UI. In particular, the application uses jQuery templates to format and display the reference entries. Each of the separate templates is stored in a separate ASP.NET user control in a folder named Templates: The contents of the user controls (and therefore the templates) are combined in the default.aspx page: <!-- Templates --> <user:EntryTemplate runat="server" /> <user:EntryDetailsTemplate runat="server" /> <user:BrowsersTemplate runat="server" /> <user:EditEntryTemplate runat="server" /> <user:EntryDetailsCloudTemplate runat="server" /> When the default.aspx page is requested, all of the templates are retrieved in a single page. WCF Data Services The JavaScript Reference application uses WCF Data Services to retrieve and modify database data. The application exposes a server-side WCF Data Service named EntryService.svc that supports querying, adding, updating, and deleting entries. jQuery Ajax calls are made against the WCF Data Service to perform the database operations from the browser. The OData protocol makes this easy. Authentication is handled on the server with a ChangeInterceptor. Only authenticated users are allowed to update the JavaScript Reference entry database. JavaScript Unit Tests In order to build the JavaScript Reference application, I depended on JavaScript unit tests. I needed the unit tests, in particular, to write the JavaScript merge functions which merge entry change sets from the server with existing entries in browser local storage. In order for unit tests to be useful, they need to run fast. I ran my unit tests after each build. For this reason, I did not want to run the unit tests within the context of a browser. Instead, I ran the unit tests using server-side JavaScript (the Microsoft Script Control). The source code that you can download at the end of this blog entry includes a project named JavaScriptReference.UnitTests that contains all of the JavaScripts unit tests. JavaScript Integration Tests Because not every feature of an application can be tested by unit tests, the JavaScript Reference application also includes integration tests. I wrote the integration tests using Selenium RC in combination with ASP.NET Unit Tests. The Selenium tests run against all of the target browsers for the JavaScript Reference application: IE 8, Chrome 8, Firefox 3.6, and Safari 5. For example, here is the Selenium test that checks whether authenticating with a valid user name and password correctly switches the application to Admin Mode: [TestMethod] [HostType("ASP.NET")] [UrlToTest("http://localhost:26303/JavaScriptReference")] [AspNetDevelopmentServerHost(@"C:\Users\Stephen\Documents\Repos\JavaScriptReference\JavaScriptReference\JavaScriptReference", "/JavaScriptReference")] public void TestValidLogin() { // Run test for each controller foreach (var controller in this.Controllers) { var selenium = controller.Value; var browserName = controller.Key; // Open reference page. selenium.Open("http://localhost:26303/JavaScriptReference/default.aspx"); // Click login button displays login form selenium.Click("btnLogin"); Assert.IsTrue(selenium.IsVisible("loginForm"), "Login form appears after clicking btnLogin"); // Enter user name and password selenium.Type("userName", "Admin"); selenium.Type("password", "secret"); selenium.Click("btnDoLogin"); // Should set adminMode == true selenium.WaitForCondition("selenium.browserbot.getCurrentWindow().adminMode==true", "30000"); } }   The results for running the Selenium tests appear in the Test Results window just like the unit tests: The Selenium tests take much longer to execute than the unit tests. However, they provide test coverage for actual browsers. Furthermore, if you are using Visual Studio ALM, you can run the tests automatically every night as part of your standard nightly build. You can view the Selenium tests by opening the JavaScriptReference.QATests project. Summary I plan to write more detailed blog entries about this application over the next week. I want to discuss each of the features – HTML5 local storage, HTML5 offline apps, jQuery templates, automatic script combining and minification, JavaScript unit tests, Selenium tests -- in more detail. You can download the source control for the JavaScript Reference Application by clicking the following link: Download You need Visual Studio 2010 and ASP.NET 4 to build the application. Before running the JavaScript unit tests, install the Microsoft Script Control. Before running the Selenium tests, start the Selenium server by running the StartSeleniumServer.bat file located in the JavaScriptReference.QATests project.

    Read the article

  • Customize the Windows Media Center Start Menu with Media Center Studio

    - by DigitalGeekery
    Do you ever wish you could change the WMC start menu? Maybe move some of the tiles and strips around to different locations, add new ones, or eliminate some altogether? Today we look at how to do it using Media Center Studio. Download and install Media Center Studio. (Download link below) You’ll also want to make sure you have Windows Media Center closed before running Media Center Studio. Many of the actions cannot be performed with Media Center open. Once installed, you can open Media Center Studio from the Windows Start Menu. When you first open Media Center Studio you’ll be on the Themes tab. Click on the Start Menu tab. It should be noted that Media Center Studio is a Beta application, and it did crash on us a few times, so it’s a good idea to save your work frequently. You can save your changes by selecting Save on the Home tab, or by clicking the small disk icon at the top left. We also found that that trying to launch Media Center from the Start Media Center button on the application ribbon typically didn’t work. Opening Windows Media Center from the Windows Start Menu is preferred.   When you’re on the Start Menu tab you will see the Windows Media Center menu strips and tiles. Click the arrows located at the right, left, top, and bottom of the screen to scroll through the various menu strips.   Hiding and Removing Tiles and Menu Strips. If there is an entire menu strip that you never use and would like to remove from Media Center, simply uncheck the box to the left of the the title above that menu strip. If you’d like to hide individual tiles, uncheck the box next to the name of the individual tile. Renaming Tiles and Strips To rename a tile or menu strip, click on the small notepad icon next to the title. Note: If you do not see a small notepad icon next to the title, then the title is not editable. This applies to many of the “Promo” tiles. The title will turn into a text input box so that you can edit the name. Click away from the text box when finished. Here we will change the title of the default Movie strip to “Flicks.” Change the Default Tile and Menu Strip The Default menu strip is the strip that is highlighted, or on focus, when you open Media Center.   To change the default strip, simply click once on another strip to highlight it, and then save your work. In our example, I’m going to make our newly renamed “Flicks” strip the default.   Each menu strip has a default tile. This is the tile that is active, or on focus, when you select the menu strip. To change the default tile on a strip, click once on the tile. You will see it outlined in light blue. Now just simply save your changes. In our example below, we’ve changed the default tile on the TV strip to “guide.”   Moving Tiles and Menu Strips You can move an entire Menu Strip up or down on the screen. When you hover your mouse over the a menu strip, you will see up and down arrows appear to the right and left of the title. Click on the arrows to move the strip up or down.   You will see the menu strip appear in it’s new position.   To move a tile to a new menu strip, click and drag the tile you’d like to move. When you begin to drag the tile, green plus (+) signs will appear in between the tiles. Drag and drop the tile onto to any of these green plus signs to move it to that location. When you’ve dragged the tile over an acceptable position, you’ll see the  red “Move” label next to your cursor turn to a blue “Move to” label. Now you can drop the tile into position. You’ll see the tile located in it’s new position.   Adding a New Custom Menu Strip Click on the Start Menu tab and then select the Menu Strip button.   You will see a new Custom Menu strip appear on your Start Menu with the default name of Custom menu. You can change the name by clicking on the notepad icon just as we did earlier. For our example, we’ll change the name of the new strip to Add-ins. To add a new tile, click on Entry Points at the lower left of the application window. This will reveal all of your available Entry Points that can be added to the Media Center Menu. You should see the built-in Media Center Games and any Media Center Plug-ins you have added to your system. You can then drag and drop any of the Entry Points onto any of the Menu Strips. Below we’ve added Media Browser to our custom Add-ins menu strip. You can also add additional applications to launch directly from Media Center. Click on the Application button on the Start Menu tab. Note: Many applications may not work with your remote, but with keyboard and mouse only.    Type in a title which will appear under the tile in Media Center, and then type the path to the application. In our example, we will add Internet Explorer 8. Note: Be sure to add the actual path to the application and not just a link on the desktop. Click any of the check boxes to select any options under Required Capabilities. You can also browse to choose an image if you don’t care for the image that appears automatically.   Next, you can select keyboard strokes to press to exit the application and return to Media Center. Click the green plus (+) button. When prompted, press a key you’ll use to close the program. Repeat the process if you’d also like to select a keystroke to kill the program.   You’ll see your button programs listed below. When you’re finished, save your work and close out of Media Center Studio.   Now your new program entry point will appear in the Entry Points section. Drag the icon to the desired position on the Start Menu and save again before exiting Media Center Studio. When you open Media Center you will see your new application on the start menu. Click the tile to open the application just as you would any other tile. The application will open and minimize Media Center. When you press the key you choose to close the program, Windows Media Center will automatically be restored. Note: You can also exit the application through normal methods by clicking the red “X” or File > Exit. Conclusion Media Center Studio is a Beta application which the developer freely admits still has some bugs. Despite it’s flaws Media Center Studio is a powerful tool, and when it comes to customizing your Media Center start menu, it’s pretty much the only game in town. It works with both Vista and Windows 7, and according to the developer, has not been officially tested with extenders. Media Center Studio can also be used to add custom themes to Windows 7 Media Center and we’ll be covering that in a future article. Looking for more ways to customize your Media Center experience? Be sure to check out our earlier posts on Media Browser, as well as how to add Hulu, Boxee, and weather conditions your Windows 7 Media Center. Download Media Center Studio Similar Articles Productive Geek Tips Using Netflix Watchnow in Windows Vista Media Center (Gmedia)How To Rip a Music CD in Windows 7 Media CenterSchedule Updates for Windows Media CenterStartup Customizations for Media Center in Windows 7Automatically Start Windows 7 Media Center in Live TV Mode TouchFreeze Alternative in AutoHotkey The Icy Undertow Desktop Windows Home Server – Backup to LAN The Clear & Clean Desktop Use This Bookmarklet to Easily Get Albums Use AutoHotkey to Assign a Hotkey to a Specific Window Latest Software Reviews Tinyhacker Random Tips Acronis Online Backup DVDFab 6 Revo Uninstaller Pro Registry Mechanic 9 for Windows Video Toolbox is a Superb Online Video Editor Fun with 47 charts and graphs Tomorrow is Mother’s Day Check the Average Speed of YouTube Videos You’ve Watched OutlookStatView Scans and Displays General Usage Statistics How to Add Exceptions to the Windows Firewall

    Read the article

  • Failed Castle ActiveRecord TransactionScope causes future queries to be invalid

    - by mbp
    I am trying to solve an issue when using a Castle ActiveRecord TransactionScope which is rolled back. After the rollback, I am unable to query the Dog table. The "Dog.FindFirst()" line fails with "Could not perform SlicedFindAll for Dog", because it cannot insert dogMissingName. using (new SessionScope()) { try { var trans = new TransactionScope(TransactionMode.New, OnDispose.Commit); try { var dog = new Dog { Name = "Snowy" }; dog.Save(); var dogMissingName = new Dog(); dogMissingName.Save(); } catch (Exception) { trans.VoteRollBack(); throw; } finally { trans.Dispose(); } } catch (Exception ex) { var randomDog = Dog.FindFirst() Console.WriteLine("Random dog : " + randomDog.Name); } } Stacktrace is as follows: Castle.ActiveRecord.Framework.ActiveRecordException: Could not perform SlicedFindAll for Dog ---> NHibernate.Exceptions.GenericADOException: could not insert: [Mvno.Dal.Dog#219e86fa-1081-490a-92d1-9d480171fcfd][SQL: INSERT INTO Dog (Name, Id) VALUES (?, ?)] ---> System.Data.SqlClient.SqlException: Cannot insert the value NULL into column 'Name', table 'Dog'; column does not allow nulls. INSERT fails. The statement has been terminated. ved System.Data.SqlClient.SqlConnection.OnError(SqlException exception, Boolean breakConnection) ved System.Data.SqlClient.SqlInternalConnection.OnError(SqlException exception, Boolean breakConnection) ved System.Data.SqlClient.TdsParser.ThrowExceptionAndWarning(TdsParserStateObject stateObj) ved System.Data.SqlClient.TdsParser.Run(RunBehavior runBehavior, SqlCommand cmdHandler, SqlDataReader dataStream, BulkCopySimpleResultSet bulkCopyHandler, TdsParserStateObject stateObj) ved System.Data.SqlClient.SqlCommand.FinishExecuteReader(SqlDataReader ds, RunBehavior runBehavior, String resetOptionsString) ved System.Data.SqlClient.SqlCommand.RunExecuteReaderTds(CommandBehavior cmdBehavior, RunBehavior runBehavior, Boolean returnStream, Boolean async) ved System.Data.SqlClient.SqlCommand.RunExecuteReader(CommandBehavior cmdBehavior, RunBehavior runBehavior, Boolean returnStream, String method, DbAsyncResult result) ved System.Data.SqlClient.SqlCommand.InternalExecuteNonQuery(DbAsyncResult result, String methodName, Boolean sendToPipe) ved System.Data.SqlClient.SqlCommand.ExecuteNonQuery() ved NHibernate.AdoNet.AbstractBatcher.ExecuteNonQuery(IDbCommand cmd) ved NHibernate.AdoNet.NonBatchingBatcher.AddToBatch(IExpectation expectation) ved NHibernate.Persister.Entity.AbstractEntityPersister.Insert(Object id, Object[] fields, Boolean[] notNull, Int32 j, SqlCommandInfo sql, Object obj, ISessionImplementor session) --- End of inner exception stack trace --- ved NHibernate.Persister.Entity.AbstractEntityPersister.Insert(Object id, Object[] fields, Boolean[] notNull, Int32 j, SqlCommandInfo sql, Object obj, ISessionImplementor session) ved NHibernate.Persister.Entity.AbstractEntityPersister.Insert(Object id, Object[] fields, Object obj, ISessionImplementor session) ved NHibernate.Action.EntityInsertAction.Execute() ved NHibernate.Engine.ActionQueue.Execute(IExecutable executable) ved NHibernate.Engine.ActionQueue.ExecuteActions(IList list) ved NHibernate.Engine.ActionQueue.ExecuteActions() ved NHibernate.Event.Default.AbstractFlushingEventListener.PerformExecutions(IEventSource session) ved NHibernate.Event.Default.DefaultAutoFlushEventListener.OnAutoFlush(AutoFlushEvent event) ved NHibernate.Impl.SessionImpl.AutoFlushIfRequired(ISet`1 querySpaces) ved NHibernate.Impl.SessionImpl.List(CriteriaImpl criteria, IList results) ved NHibernate.Impl.CriteriaImpl.List(IList results) ved NHibernate.Impl.CriteriaImpl.List() ved Castle.ActiveRecord.ActiveRecordBase.SlicedFindAll(Type targetType, Int32 firstResult, Int32 maxResults, Order[] orders, ICriterion[] criteria) --- End of inner exception stack trace --- ved Castle.ActiveRecord.ActiveRecordBase.SlicedFindAll(Type targetType, Int32 firstResult, Int32 maxResults, Order[] orders, ICriterion[] criteria) ved Castle.ActiveRecord.ActiveRecordBase.FindFirst(Type targetType, Order[] orders, ICriterion[] criteria) ved Castle.ActiveRecord.ActiveRecordBase.FindFirst(Type targetType, ICriterion[] criteria) ved Castle.ActiveRecord.ActiveRecordBase`1.FindFirst(ICriterion[] criteria)

    Read the article

  • SQL SERVER – Automated Type Conversion using Expressor Studio

    - by pinaldave
    Recently I had an interesting situation during my consultation project. Let me share to you how I solved the problem using Expressor Studio. Consider a situation in which you need to read a field, such as customer_identifier, from a text file and pass that field into a database table. In the source file’s metadata structure, customer_identifier is described as a string; however, in the target database table, customer_identifier is described as an integer. Legitimately, all the source values for customer_identifier are valid numbers, such as “109380”. To implement this in an ETL application, you probably would have hard-coded a type conversion function call, such as: output.customer_identifier=stringToInteger(input.customer_identifier) That wasn’t so bad, was it? For this instance, programming this hard-coded type conversion function call was relatively easy. However, hard-coding, whether type conversion code or other business rule code, almost always means that the application containing hard-coded fields, function calls, and values is: a) specific to an instance of use; b) is difficult to adapt to new situations; and c) doesn’t contain many reusable sub-parts. Therefore, in the long run, applications with hard-coded type conversion function calls don’t scale well. In addition, they increase the overall level of effort and degree of difficulty to write and maintain the ETL applications. To get around the trappings of hard-coding type conversion function calls, developers need an access to smarter typing systems. Expressor Studio product offers this feature exactly, by providing developers with a type conversion automation engine based on type abstraction. The theory behind the engine is quite simple. A user specifies abstract data fields in the engine, and then writes applications against the abstractions (whereas in most ETL software, developers develop applications against the physical model). When a Studio-built application is run, Studio’s engine automatically converts the source type to the abstracted data field’s type and converts the abstracted data field’s type to the target type. The engine can do this because it has a couple of built-in rules for type conversions. So, using the example above, a developer could specify customer_identifier as an abstract data field with a type of integer when using Expressor Studio. Upon reading the string value from the text file, Studio’s type conversion engine automatically converts the source field from the type specified in the source’s metadata structure to the abstract field’s type. At the time of writing the data value to the target database, the engine doesn’t have any work to do because the abstract data type and the target data type are just the same. Had they been different, the engine would have automatically provided the conversion. ?Reference: Pinal Dave (http://blog.SQLAuthority.com) Filed under: Database, Pinal Dave, SQL, SQL Authority, SQL Query, SQL Scripts, SQL Server, SQL Tips and Tricks, SQLAuthority News, T SQL, Technology Tagged: SSIS

    Read the article

  • Can't make AWUS036H work in Ubuntu 12.10

    - by sfrj
    I am using 64 bit Ubuntu 12.10. This is my kernel version: Linux 3.5.0-19-generic #30-Ubuntu SMP Tue Nov 13 17:48:01 UTC 2012 x86_64 x86_64 x86_64 GNU/Linux My wireless card is an AWUSU36H The first thing I do to install the driver is copy the driver from the CD to the Downloads folder. cd /media/me/AWUS036H/Drivers/RTL8187L/Unix (Linux)/Linux driver for kernel 2.6.X$ cp rtl8187_linux_26.1025.0328.2007.tar.gz ~/Downloads/ Then I extract the tar tar xvfz rtl8187_linux_26.1025.0328.2007.tar.gz I navigate into the extracted folder, and I try to follow the instructions in the Readme.txt cd rtl8187_linux_26.1025.0328.2007 This are the contents of the folder: drv.tar.gz makedrv stack.tar.gz wlan0rmv ieee80211 ReadMe.txt wlan0dhcp wlan0up ifcfg-wlan0 rtl8187 wlan0down wpa_supplicant-0.4.9 This is what the Readme.txt says: Release Date: 2006-02-09, ver 1.2^M RTL8187 Linux driver version 1.2^M ^M --This driver supports RealTek RTL8187 Wireless LAN driver for ^M Fedora Core 2/3/4/5, Debian 3.1, Mandrake 10.2/Mandriva 2006, ^M SUSE 9.3/10.1/10.2, Gentoo 3.1, etc.^M - Support Client mode for either infrastructure or adhoc mode^M - Support WEP and WPAPSK connection^M ^M < Component >^M The driver is composed of several parts:^M 1. Module source code^M stack.tar.gz^M drv.tar.gz^M ^M 2. Script ot build the modules^M makedrv^M ^M 3. Script to load/unload modules^M wlan0up^M wlan0down ^M ^M 4. Script and configuration for DHCP^M "ReadMe.txt" [readonly] 140 lines, 4590 characters So what I do know is extract both of the compressed files: sudo tar xvfz drv.tar.gz sudo tar xvfz stack.tar.gz This 2 commands will add some data to the folders ieee80211 and rtl8187 At this point I get lost, and I don't know what to do. If I go in each of this 2 folders and I run the sudo make command then I get errors like this one: sudo makemake -C /lib/modules/3.5.0-19-generic/build M=/home/me/Downloads/rtl8187_linux_26.1025.0328.2007/rtl8187 modules make[1]: Entering directory `/usr/src/linux-headers-3.5.0-19-generic' CC [M] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/rtl8187/r8187_core.o In file included from /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/rtl8187/r8187_core.c:64:0: /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/rtl8187/r8187.h:29:26: fatal error: linux/config.h: No such file or directory compilation terminated. make[2]: *** [/home/me/Downloads/rtl8187_linux_26.1025.0328.2007/rtl8187/r8187_core.o] Error 1 make[1]: *** [_module_/home/me/Downloads/rtl8187_linux_26.1025.0328.2007/rtl8187] Error 2 make[1]: Leaving directory `/usr/src/linux-headers-3.5.0-19-generic' make: *** [modules] Error 2 If I try to run any of the script ./makedrv that the instructions describe, then I also get an error: ~/Downloads/rtl8187_linux_26.1025.0328.2007$ sudo ./makedrv [sudo] password for me: ieee80211/ ieee80211/license ieee80211/ieee80211_crypt.c ieee80211/ieee80211_tx.c ieee80211/ieee80211_softmac.c ieee80211/ieee80211_softmac_wx.c ieee80211/ieee80211_module.c ieee80211/ieee80211_crypt_ccmp.c ieee80211/ieee80211_rx.c ieee80211/tags ieee80211/ieee80211_crypt_tkip.c ieee80211/Makefile ieee80211/readme ieee80211/.tmp_versions/ ieee80211/.tmp_versions/ieee80211-rtl.mod ieee80211/.tmp_versions/ieee80211_crypt_wep-rtl.mod ieee80211/.tmp_versions/ieee80211_crypt_tkip-rtl.mod ieee80211/.tmp_versions/ieee80211_crypt-rtl.mod ieee80211/.tmp_versions/ieee80211_crypt_ccmp-rtl.mod ieee80211/ieee80211_crypt_wep.c ieee80211/ieee80211.h ieee80211/ieee80211_wx.c ieee80211/ieee80211_crypt.h rtl8187/ rtl8187/license rtl8187/r8180_rtl8225z2.c rtl8187/r8180_rtl8225.h rtl8187/r8187_led.c rtl8187/r8180_93cx6.h rtl8187/r8180_wx.h rtl8187/r8180_hw.h rtl8187/copying rtl8187/r8187_led.h rtl8187/r8180_pm.h rtl8187/tags rtl8187/r8187.h rtl8187/Makefile rtl8187/r8180_rtl8225.c rtl8187/readme rtl8187/install rtl8187/.tmp_versions/ rtl8187/.tmp_versions/r8187.mod rtl8187/changes rtl8187/r8180_wx.c rtl8187/r8180_pm.c rtl8187/r8187_core.c rtl8187/r8180_93cx6.c rtl8187/authors rtl8187/ieee80211.h rtl8187/ieee80211_crypt.h rm -f *.mod.c *.mod *.o .*.cmd *.ko *~ rm -rf /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/tmp make -C /lib/modules/3.5.0-19-generic/build M=/home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211 modules make[1]: Entering directory `/usr/src/linux-headers-3.5.0-19-generic' CC [M] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.o In file included from /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:17:0: /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211.h:1019:24: error: field ‘ps_task’ has incomplete type /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c: In function ‘ieee80211_softmac_scan_wq’: /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:421:2: warning: passing argument 2 of ‘queue_delayed_work’ from incompatible pointer type [enabled by default] In file included from include/linux/srcu.h:32:0, from include/linux/notifier.h:15, from /usr/src/linux-headers-3.5.0-19-generic/arch/x86/include/asm/uprobes.h:26, from include/linux/uprobes.h:35, from include/linux/mm_types.h:15, from include/linux/kmemcheck.h:4, from include/linux/skbuff.h:18, from include/linux/if_ether.h:134, from /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211.h:26, from /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:17: include/linux/workqueue.h:371:12: note: expected ‘struct delayed_work *’ but argument is of type ‘struct work_struct *’ /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c: In function ‘ieee80211_softmac_stop_scan’: /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:495:3: warning: passing argument 1 of ‘cancel_delayed_work’ from incompatible pointer type [enabled by default] In file included from include/linux/srcu.h:32:0, from include/linux/notifier.h:15, from /usr/src/linux-headers-3.5.0-19-generic/arch/x86/include/asm/uprobes.h:26, from include/linux/uprobes.h:35, from include/linux/mm_types.h:15, from include/linux/kmemcheck.h:4, from include/linux/skbuff.h:18, from include/linux/if_ether.h:134, from /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211.h:26, from /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:17: include/linux/workqueue.h:410:20: note: expected ‘struct delayed_work *’ but argument is of type ‘struct work_struct *’ /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c: In function ‘ieee80211_associate_abort’: /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:915:2: warning: passing argument 2 of ‘queue_delayed_work’ from incompatible pointer type [enabled by default] In file included from include/linux/srcu.h:32:0, from include/linux/notifier.h:15, from /usr/src/linux-headers-3.5.0-19-generic/arch/x86/include/asm/uprobes.h:26, from include/linux/uprobes.h:35, from include/linux/mm_types.h:15, from include/linux/kmemcheck.h:4, from include/linux/skbuff.h:18, from include/linux/if_ether.h:134, from /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211.h:26, from /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:17: include/linux/workqueue.h:371:12: note: expected ‘struct delayed_work *’ but argument is of type ‘struct work_struct *’ /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c: In function ‘ieee80211_rx_frame_softmac’: /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:1527:3: error: implicit declaration of function ‘tasklet_schedule’ [-Werror=implicit-function-declaration] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c: In function ‘ieee80211_stop_protocol_rtl’: /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2120:2: warning: passing argument 1 of ‘cancel_delayed_work’ from incompatible pointer type [enabled by default] In file included from include/linux/srcu.h:32:0, from include/linux/notifier.h:15, from /usr/src/linux-headers-3.5.0-19-generic/arch/x86/include/asm/uprobes.h:26, from include/linux/uprobes.h:35, from include/linux/mm_types.h:15, from include/linux/kmemcheck.h:4, from include/linux/skbuff.h:18, from include/linux/if_ether.h:134, from /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211.h:26, from /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:17: include/linux/workqueue.h:410:20: note: expected ‘struct delayed_work *’ but argument is of type ‘struct work_struct *’ /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c: In function ‘ieee80211_softmac_init’: /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2229:78: error: macro "INIT_WORK" passed 3 arguments, but takes just 2 /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2229:2: error: ‘INIT_WORK’ undeclared (first use in this function) /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2229:2: note: each undeclared identifier is reported only once for each function it appears in /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2230:88: error: macro "INIT_WORK" passed 3 arguments, but takes just 2 /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2231:94: error: macro "INIT_WORK" passed 3 arguments, but takes just 2 /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2232:96: error: macro "INIT_WORK" passed 3 arguments, but takes just 2 /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2233:82: error: macro "INIT_WORK" passed 3 arguments, but takes just 2 /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2234:82: error: macro "INIT_WORK" passed 3 arguments, but takes just 2 /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2244:2: error: implicit declaration of function ‘tasklet_init’ [-Werror=implicit-function-declaration] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c: In function ‘ieee80211_softmac_free’: /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2255:2: warning: passing argument 1 of ‘cancel_delayed_work’ from incompatible pointer type [enabled by default] In file included from include/linux/srcu.h:32:0, from include/linux/notifier.h:15, from /usr/src/linux-headers-3.5.0-19-generic/arch/x86/include/asm/uprobes.h:26, from include/linux/uprobes.h:35, from include/linux/mm_types.h:15, from include/linux/kmemcheck.h:4, from include/linux/skbuff.h:18, from include/linux/if_ether.h:134, from /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211.h:26, from /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:17: include/linux/workqueue.h:410:20: note: expected ‘struct delayed_work *’ but argument is of type ‘struct work_struct *’ /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c: In function ‘ieee80211_wpa_set_encryption’: /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2489:3: error: implicit declaration of function ‘request_module’ [-Werror=implicit-function-declaration] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2518:3: error: implicit declaration of function ‘try_module_get’ [-Werror=implicit-function-declaration] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c: At top level: /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2663:1: warning: data definition has no type or storage class [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2663:1: warning: type defaults to ‘int’ in declaration of ‘EXPORT_SYMBOL’ [-Wimplicit-int] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2663:1: warning: parameter names (without types) in function declaration [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2664:1: warning: data definition has no type or storage class [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2664:1: warning: type defaults to ‘int’ in declaration of ‘EXPORT_SYMBOL’ [-Wimplicit-int] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2664:1: warning: parameter names (without types) in function declaration [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2665:1: warning: data definition has no type or storage class [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2665:1: warning: type defaults to ‘int’ in declaration of ‘EXPORT_SYMBOL’ [-Wimplicit-int] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2665:1: warning: parameter names (without types) in function declaration [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2666:1: warning: data definition has no type or storage class [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2666:1: warning: type defaults to ‘int’ in declaration of ‘EXPORT_SYMBOL’ [-Wimplicit-int] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2666:1: warning: parameter names (without types) in function declaration [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2667:1: warning: data definition has no type or storage class [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2667:1: warning: type defaults to ‘int’ in declaration of ‘EXPORT_SYMBOL’ [-Wimplicit-int] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2667:1: warning: parameter names (without types) in function declaration [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2668:1: warning: data definition has no type or storage class [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2668:1: warning: type defaults to ‘int’ in declaration of ‘EXPORT_SYMBOL’ [-Wimplicit-int] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2668:1: warning: parameter names (without types) in function declaration [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2669:1: warning: data definition has no type or storage class [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2669:1: warning: type defaults to ‘int’ in declaration of ‘EXPORT_SYMBOL’ [-Wimplicit-int] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2669:1: warning: parameter names (without types) in function declaration [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2670:1: warning: data definition has no type or storage class [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2670:1: warning: type defaults to ‘int’ in declaration of ‘EXPORT_SYMBOL’ [-Wimplicit-int] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2670:1: warning: parameter names (without types) in function declaration [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2671:1: warning: data definition has no type or storage class [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2671:1: warning: type defaults to ‘int’ in declaration of ‘EXPORT_SYMBOL’ [-Wimplicit-int] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2671:1: warning: parameter names (without types) in function declaration [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2672:1: warning: data definition has no type or storage class [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2672:1: warning: type defaults to ‘int’ in declaration of ‘EXPORT_SYMBOL’ [-Wimplicit-int] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2672:1: warning: parameter names (without types) in function declaration [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2673:1: warning: data definition has no type or storage class [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2673:1: warning: type defaults to ‘int’ in declaration of ‘EXPORT_SYMBOL’ [-Wimplicit-int] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2673:1: warning: parameter names (without types) in function declaration [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2674:1: warning: data definition has no type or storage class [enabled by default] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2674:1: warning: type defaults to ‘int’ in declaration of ‘EXPORT_SYMBOL’ [-Wimplicit-int] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:2674:1: warning: parameter names (without types) in function declaration [enabled by default] In file included from /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.c:17:0: /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211.h:1212:37: warning: ‘netdev_priv’ is static but used in inline function ‘ieee80211_priv’ which is not static [enabled by default] cc1: some warnings being treated as errors make[2]: *** [/home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211/ieee80211_softmac.o] Error 1 make[1]: *** [_module_/home/me/Downloads/rtl8187_linux_26.1025.0328.2007/ieee80211] Error 2 make[1]: Leaving directory `/usr/src/linux-headers-3.5.0-19-generic' make: *** [modules] Error 2 rm -f *.mod.c *.mod *.o .*.cmd *.ko *~ rm -rf /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/rtl8187/tmp make -C /lib/modules/3.5.0-19-generic/build M=/home/me/Downloads/rtl8187_linux_26.1025.0328.2007/rtl8187 modules make[1]: Entering directory `/usr/src/linux-headers-3.5.0-19-generic' CC [M] /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/rtl8187/r8187_core.o In file included from /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/rtl8187/r8187_core.c:64:0: /home/me/Downloads/rtl8187_linux_26.1025.0328.2007/rtl8187/r8187.h:29:26: fatal error: linux/config.h: No such file or directory compilation terminated. make[2]: *** [/home/me/Downloads/rtl8187_linux_26.1025.0328.2007/rtl8187/r8187_core.o] Error 1 make[1]: *** [_module_/home/me/Downloads/rtl8187_linux_26.1025.0328.2007/rtl8187] Error 2 make[1]: Leaving directory `/usr/src/linux-headers-3.5.0-19-generic' make: *** [modules] Error 2 Can somebody give me a hand finding out what I need to do to make my wifi card work? Update This is the output of the lsusb command lsusb Bus 003 Device 002: ID 147e:1000 Upek Biometric Touchchip/Touchstrip Fingerprint Sensor Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 002 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 003 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 004 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub

    Read the article

  • The importance of Unit Testing in BI

    - by Davide Mauri
    One of the main steps in the process we internally use to develop a BI solution is the implementation of Unit Test of you BI Data. As you may already know, I’ve create a simple (for now) tool that leverages NUnit to allow us to quickly create Unit Testing without having to resort to use Visual Studio Database Professional: http://queryunit.codeplex.com/ Once you have a tool like this one, you can start also to make sure that your BI solution (DWH and CUBE) is not only structurally sound (I mean, the cube or the report gets processed correctly), but you can also check that the logical integrity of your business rules is enforced. For example let’s say that the customer tell you that they will never create an invoice for a specific product-line in 2010 since that product-line is dismissed and will never be sold again. Ok we know that this in theory is true, but a lot of this business rule effectiveness depends on the fact the people does not do a mistake while inserting new orders/invoices and the ERP used implements a check for this business logic. Unfortunately these last two hypotesis are not always true, so you may find yourself really having some invoices for a product line that doesn’t exists anymore. Maybe this kind of situation in future will be solved using Master Data Management but, meanwhile, how you can give and idea of the data quality to your customers? How can you check that logical integrity of the analytical data you produce is exactly what you expect? Well, Unit Testing of a DWH or a CUBE can be a solution. Once you have defined your test suite, by writing SQL and MDX queries that checks that your data is what you expect to be, if you use NUnit (and QueryUnit does), you can then use a tool like NUnit2Report to create a nice HTML report that can be shipped via email to give information of data quality: In addition to that, since NUnit produces an XML file as a result, you can also import it into a SQL Server Database and then monitor the quality of data over time. I’ll be speaking about this approach (and more in general about how to “engineer” a BI solution) at the next European SQL PASS Adaptive BI Best Practices http://www.sqlpass.org/summit/eu2010/Agenda/ProgramSessions/AdaptiveBIBestPratices.aspx I’ll enjoy discussing with you all about this, so see you there! And remember: “if ain't tested it's broken!” (Sorry I don’t remember how said that in first place :-)) Share this post: email it! | bookmark it! | digg it! | reddit! | kick it! | live it!

    Read the article

  • Automapper: Handling NULL members

    - by PSteele
    A question about null members came up on the Automapper mailing list.  While the problem wasn’t with Automapper, investigating the issue led to an interesting feature in Automapper. Normally, Automapper ignores null members.  After all, what is there really to do?  Imagine these source classes: public class Source { public int Data { get; set; } public Address Address { get; set; } }   public class Destination { public string Data { get; set; } public Address Address { get; set; } }   public class Address { public string AddressType { get; set; } public string Location { get; set; } } And imagine a simple mapping example with these classes: Mapper.CreateMap<Source, Destination>();   var source = new Source { Data = 22, Address = new Address { AddressType = "Home", Location = "Michigan", }, };   var dest = Mapper.Map<Source, Destination>(source); The variable ‘dest’ would have a complete mapping of the Data member and the Address member. But what if the source had no address? Mapper.CreateMap<Source, Destination>();   var source = new Source { Data = 22, };   var dest = Mapper.Map<Source, Destination>(source); In that case, Automapper would just leave the Destination.Address member null as well.  But what if we always wanted an Address defined – even if it’s just got some default data?  Use the “NullSubstitute” option: Mapper.CreateMap<Source, Destination>() .ForMember(d => d.Address, o => o.NullSubstitute(new Address { AddressType = "Unknown", Location = "Unknown", }));   var source = new Source { Data = 22, };   var dest = Mapper.Map<Source, Destination>(source); Now, the ‘dest’ variable will have an Address defined with a type and location of “Unknown”.  Very handy! Technorati Tags: .NET,Automapper,NULL

    Read the article

  • How do I upload an NSImage(NSData)to Twitpic with OAMutableURLRequest?

    - by timothy5216
    I'm using OAConsumer in my xAuth twitterEngine and i'm adding Twitpic OAuth Echo to it. But it won't POST the NSData. here is some of my code: //other file NSArray *reps = [[imageToUpload image] representations]; NSData *imageData = [NSBitmapImageRep representationOfImageRepsInArray:reps usingType:NSJPEGFileType properties:nil]; [twitter testUploadImageData:imageData withMessage:@"Hello WORLD!!" toURL:[NSURL URLWithString:uploadURL.stringValue]]; // - (void)testUploadImageData:(NSData *)data withMessage:(NSString *)message toURL:(NSURL *)url; { //url = @"http://api.twitpic.com/2/upload.xml" //message = @"Hello WORLD!!" NSAutoreleasePool *pool = [[NSAutoreleasePool alloc] init]; NSString *String = [[NSString alloc] initWithData:data encoding:NSASCIIStringEncoding]; NSLog(@"dataString: %@",String); OAMutableURLRequest *request = [[OAMutableURLRequest alloc] initWithURL:url consumer:self.consumer token:_accessToken realm:nil signatureProvider:nil]; // Setup POST body [request setHTTPMethod:@"POST"]; //NSString *stringBoundary = [NSString stringWithString:@"0xKhTmLbOuNdArY"]; //NSString *contentType = [NSString stringWithFormat:@"multipart/form-data; boundary=%@", stringBoundary]; // NSString *stringBoundarySeparator = [NSString stringWithFormat:@"\r\n--%@\r\n", stringBoundary]; /* NSMutableString *postString = [NSMutableString string]; [postString appendString:@"\r\n"]; [postString appendString:stringBoundarySeparator]; [postString appendString:[NSString stringWithFormat:@"Content-Disposition: form-data; name=\"message\"\r\n\r\n%@", message]]; [postString appendString:stringBoundarySeparator]; [postString appendString:[NSString stringWithFormat:@"Content-Disposition: form-data; name=\"media\"; filename=\"%@\"\r\n", @"file.jpg"]]; [postString appendString:@"Content-Type: image/jpg\r\n"]; [postString appendString:@"Content-Transfer-Encoding: binary\r\n\r\n"]; // Setting up the POST request's multipart/form-data body NSMutableData *postBody = [NSMutableData data]; [postBody appendData:[postString dataUsingEncoding:NSUTF8StringEncoding]]; [postBody appendData:data]; [request setHTTPBody:postBody]; */ [request setHTTPMethod:@"POST"]; NSString *thing = [[NSString alloc] initWithData:data encoding:NSASCIIStringEncoding]; NSLog(@"%@",thing); [request setParameters:[NSArray arrayWithObjects: [OARequestParameter requestParameterWithName:@"oauth_token" value:_accessToken.key], [OARequestParameter requestParameterWithName:@"X-Auth-Service-Provider" value:@"https://api.twitter.com/1/account/verify_credentials.json"], [OARequestParameter requestParameterWithName:@"key" value:@"my-key-here :P"], [OARequestParameter requestParameterWithName:@"message" value:message], //iv'e changed this many times. I was just trying this to see if it works [OARequestParameter requestParameterWithName:@"media" value:thing], nil]]; OAAsynchronousDataFetcher *dataFetcher = [[OAAsynchronousDataFetcher alloc] init]; [dataFetcher initWithRequest:request delegate:self didFinishSelector:@selector(uploadDidUpload:withData:) didFailSelector:@selector(uploadDidFail:withData:)]; [dataFetcher start]; [dataFetcher release]; [request release]; [pool drain]; } I'm authenticated but it still won't POST the data :(

    Read the article

  • Shouldn’t Bind() pass child control’s values to GridView before Page.PreRender?

    - by SourceC
    hello, For controls such as the GridView, DetailsView, and FormView controls, data-binding expressions are resolved automatically during the control's PreRender event But doesn’t data source control perform updates prior to Page.PreRender event? Meaning, shouldn’t Bind() pass child control’s values to GridView ( so they can be passed to data source control as parameters ) before data source control updates the data source, thus before Page.PreRender event? thanx

    Read the article

  • SQL SERVER – Select and Delete Duplicate Records – SQL in Sixty Seconds #036 – Video

    - by pinaldave
    Developers often face situations when they find their column have duplicate records and they want to delete it. A good developer will never delete any data without observing it and making sure that what is being deleted is the absolutely fine to delete. Before deleting duplicate data, one should select it and see if the data is really duplicate. In this video we are demonstrating two scripts – 1) selects duplicate records 2) deletes duplicate records. We are assuming that the table has a unique incremental id. Additionally, we are assuming that in the case of the duplicate records we would like to keep the latest record. If there is really a business need to keep unique records, one should consider to create a unique index on the column. Unique index will prevent users entering duplicate data into the table from the beginning. This should be the best solution. However, deleting duplicate data is also a very valid request. If user realizes that they need to keep only unique records in the column and if they are willing to create unique constraint, the very first requirement of creating a unique constraint is to delete the duplicate records. Let us see how to connect the values in Sixty Seconds: Here is the script which is used in the video. USE tempdb GO CREATE TABLE TestTable (ID INT, NameCol VARCHAR(100)) GO INSERT INTO TestTable (ID, NameCol) SELECT 1, 'First' UNION ALL SELECT 2, 'Second' UNION ALL SELECT 3, 'Second' UNION ALL SELECT 4, 'Second' UNION ALL SELECT 5, 'Second' UNION ALL SELECT 6, 'Third' GO -- Selecting Data SELECT * FROM TestTable GO -- Detecting Duplicate SELECT NameCol, COUNT(*) TotalCount FROM TestTable GROUP BY NameCol HAVING COUNT(*) > 1 ORDER BY COUNT(*) DESC GO -- Deleting Duplicate DELETE FROM TestTable WHERE ID NOT IN ( SELECT MAX(ID) FROM TestTable GROUP BY NameCol) GO -- Selecting Data SELECT * FROM TestTable GO DROP TABLE TestTable GO Related Tips in SQL in Sixty Seconds: SQL SERVER – Delete Duplicate Records – Rows SQL SERVER – Count Duplicate Records – Rows SQL SERVER – 2005 – 2008 – Delete Duplicate Rows Delete Duplicate Records – Rows – Readers Contribution Unique Nonclustered Index Creation with IGNORE_DUP_KEY = ON – A Transactional Behavior What would you like to see in the next SQL in Sixty Seconds video? Reference: Pinal Dave (http://blog.sqlauthority.com) Filed under: Database, Pinal Dave, PostADay, SQL, SQL Authority, SQL in Sixty Seconds, SQL Query, SQL Scripts, SQL Server, SQL Server Management Studio, SQL Tips and Tricks, T SQL, Technology, Video Tagged: Excel

    Read the article

  • Default Save Directory for gnome-screensaver?

    - by trent
    Are there any sort of configuration options for specifying the default save location for gnome-screenshot, or is this hard-coded into the source code? It used to be ~/Desktop, which seems to have changed to ~/Pictures (in 12.04). The only possible solution I've seen is about Setting the default name (as it includes time stamp information now instead of simply Screenshot#), but that solution doesn't really seem ideal to me. Also, this post suggested that the last save location is remembered the next time you take a screenshot, but in my experience, this doesn't seem to be the case. And in any case, following on from that, that entry in gconf-editor doesn't even seem to accurately reflect the last location, so more than likely an entry related to an older version of gnome-screenshot.

    Read the article

  • Jasper report not showing detail section

    - by Jawad Ahmad
    I have designed a report in iReport and now I am using it in my application. The problem is that the report is generated showing all the data except the detail section data. There is no database connectivity problem, as the column header shows data which is coming from database. Only the detail section of the report shows nothing, neither data from database nor any static data. What is going on?

    Read the article

  • Last chance to enter! Exceptional DBA Awards 2011

    - by Rebecca Amos
    Only 1 day left to enter the Exceptional DBA Awards! Get started on your entry today, and you could be heading to Seattle for the PASS Summit in October. All you need to do is visit the Exceptional DBA website and answer a few questions about: Your career and achievements as a SQL Server DBAAny mistakes you've made along the way (and how you tackled them)Activities you're involved in within the SQL Server community – for example writing, blogging, contributing to forums, speaking at events, or organising user groupsWhy you think you should be the Exceptional DBA of 2011 As well as the respect and recognition of your peers – and a great boost to your CV – you could win full conference registration to this year's PASS Summit in Seattle (including accommodation and $300 towards travel expenses) – where the award will be presented, as well as a copy of Red Gate's SQL DBA Bundle, and a chance to be featured here, on Simple-Talk.com. So why not give it a shot? Start your entry now at www.exceptionaldba.com (nominations close on 30 June).

    Read the article

  • Partition Wise Joins II

    - by jean-pierre.dijcks
    One of the things that I did not talk about in the initial partition wise join post was the effect it has on resource allocation on the database server. When Oracle applies a different join method - e.g. not PWJ - what you will see in SQL Monitor (in Enterprise Manager) or in an Explain Plan is a set of producers and a set of consumers. The producers scan the tables in the the join. If there are two tables the producers first scan one table, then the other. The producers thus provide data to the consumers, and when the consumers have the data from both scans they do the join and give the data to the query coordinator. Now that behavior means that if you choose a degree of parallelism of 4 to run such query with, Oracle will allocate 8 parallel processes. Of these 8 processes 4 are producers and 4 are consumers. The consumers only actually do work once the producers are fully done with scanning both sides of the join. In the plan above you can see that the producers access table SALES [line 11] and then do a PX SEND [line 9]. That is the producer set of processes working. The consumers receive that data [line 8] and twiddle their thumbs while the producers go on and scan CUSTOMERS. The producers send that data to the consumer indicated by PX SEND [line 5]. After receiving that data [line 4] the consumers do the actual join [line 3] and give the data to the QC [line 2]. BTW, the myth that you see twice the number of processes due to the setting PARALLEL_THREADS_PER_CPU=2 is obviously not true. The above is why you will see 2 times the processes of the DOP. In a PWJ plan the consumers are not present. Instead of producing rows and giving those to different processes, a PWJ only uses a single set of processes. Each process reads its piece of the join across the two tables and performs the join. The plan here is notably different from the initial plan. First of all the hash join is done right on top of both table scans [line 8]. This query is a little more complex than the previous so there is a bit of noise above that bit of info, but for this post, lets ignore that (sort stuff). The important piece here is that the PWJ plan typically will be faster and from a PX process number / resources typically cheaper. You may want to look out for those plans and try to get those to appear a lot... CREDITS: credits for the plans and some of the info on the plans go to Maria, as she actually produced these plans and is the expert on plans in general... You can see her talk about explaining the explain plan and other optimizer stuff over here: ODTUG in Washington DC, June 27 - July 1 On the Optimizer blog At OpenWorld in San Francisco, September 19 - 23 Happy joining and hope to see you all at ODTUG and OOW...

    Read the article

  • Metro: Understanding the default.js File

    - by Stephen.Walther
    The goal of this blog entry is to describe — in painful detail — the contents of the default.js file in a Metro style application written with JavaScript. When you use Visual Studio to create a new Metro application then you get a default.js file automatically. The file is located in a folder named \js\default.js. The default.js file kicks off all of your custom JavaScript code. It is the main entry point to a Metro application. The default contents of the default.js file are included below: // For an introduction to the Blank template, see the following documentation: // http://go.microsoft.com/fwlink/?LinkId=232509 (function () { "use strict"; var app = WinJS.Application; app.onactivated = function (eventObject) { if (eventObject.detail.kind === Windows.ApplicationModel.Activation.ActivationKind.launch) { if (eventObject.detail.previousExecutionState !== Windows.ApplicationModel.Activation.ApplicationExecutionState.terminated) { // TODO: This application has been newly launched. Initialize // your application here. } else { // TODO: This application has been reactivated from suspension. // Restore application state here. } WinJS.UI.processAll(); } }; app.oncheckpoint = function (eventObject) { // TODO: This application is about to be suspended. Save any state // that needs to persist across suspensions here. You might use the // WinJS.Application.sessionState object, which is automatically // saved and restored across suspension. If you need to complete an // asynchronous operation before your application is suspended, call // eventObject.setPromise(). }; app.start(); })(); There are several mysterious things happening in this file. The purpose of this blog entry is to dispel this mystery. Understanding the Module Pattern The first thing that you should notice about the default.js file is that the entire contents of this file are enclosed within a self-executing JavaScript function: (function () { ... })(); Metro applications written with JavaScript use something called the module pattern. The module pattern is a common pattern used in JavaScript applications to create private variables, objects, and methods. Anything that you create within the module is encapsulated within the module. Enclosing all of your custom code within a module prevents you from stomping on code from other libraries accidently. Your application might reference several JavaScript libraries and the JavaScript libraries might have variables, objects, or methods with the same names. By encapsulating your code in a module, you avoid overwriting variables, objects, or methods in the other libraries accidently. Enabling Strict Mode with “use strict” The first statement within the default.js module enables JavaScript strict mode: 'use strict'; Strict mode is a new feature of ECMAScript 5 (the latest standard for JavaScript) which enables you to make JavaScript more strict. For example, when strict mode is enabled, you cannot declare variables without using the var keyword. The following statement would result in an exception: hello = "world!"; When strict mode is enabled, this statement throws a ReferenceError. When strict mode is not enabled, a global variable is created which, most likely, is not what you want to happen. I’d rather get the exception instead of the unwanted global variable. The full specification for strict mode is contained in the ECMAScript 5 specification (look at Annex C): http://www.ecma-international.org/publications/files/ECMA-ST/ECMA-262.pdf Aliasing the WinJS.Application Object The next line of code in the default.js file is used to alias the WinJS.Application object: var app = WinJS.Application; This line of code enables you to use a short-hand syntax when referring to the WinJS.Application object: for example,  app.onactivated instead of WinJS.Application.onactivated. The WinJS.Application object  represents your running Metro application. Handling Application Events The default.js file contains an event handler for the WinJS.Application activated event: app.onactivated = function (eventObject) { if (eventObject.detail.kind === Windows.ApplicationModel.Activation.ActivationKind.launch) { if (eventObject.detail.previousExecutionState !== Windows.ApplicationModel.Activation.ApplicationExecutionState.terminated) { // TODO: This application has been newly launched. Initialize // your application here. } else { // TODO: This application has been reactivated from suspension. // Restore application state here. } WinJS.UI.processAll(); } }; This WinJS.Application class supports the following events: · loaded – Happens after browser DOMContentLoaded event. After this event, the DOM is ready and you can access elements in a page. This event is raised before external images have been loaded. · activated – Triggered by the Windows.UI.WebUI.WebUIApplication activated event. After this event, the WinRT is ready. · ready – Happens after both loaded and activated events. · unloaded – Happens before application is unloaded. The following default.js file has been modified to capture each of these events and write a message to the Visual Studio JavaScript Console window: (function () { "use strict"; var app = WinJS.Application; WinJS.Application.onloaded = function (e) { console.log("Loaded"); }; WinJS.Application.onactivated = function (e) { console.log("Activated"); }; WinJS.Application.onready = function (e) { console.log("Ready"); } WinJS.Application.onunload = function (e) { console.log("Unload"); } app.start(); })(); When you execute the code above, a message is written to the Visual Studio JavaScript Console window when each event occurs with the exception of the Unload event (presumably because the console is not attached when that event is raised).   Handling Different Activation Contexts The code for the activated handler in the default.js file looks like this: app.onactivated = function (eventObject) { if (eventObject.detail.kind === Windows.ApplicationModel.Activation.ActivationKind.launch) { if (eventObject.detail.previousExecutionState !== Windows.ApplicationModel.Activation.ApplicationExecutionState.terminated) { // TODO: This application has been newly launched. Initialize // your application here. } else { // TODO: This application has been reactivated from suspension. // Restore application state here. } WinJS.UI.processAll(); } }; Notice that the code contains a conditional which checks the Kind of the event (the value of e.detail.kind). The startup code is executed only when the activated event is triggered by a Launch event, The ActivationKind enumeration has the following values: · launch · search · shareTarget · file · protocol · fileOpenPicker · fileSavePicker · cacheFileUpdater · contactPicker · device · printTaskSettings · cameraSettings Metro style applications can be activated in different contexts. For example, a camera application can be activated when modifying camera settings. In that case, the ActivationKind would be CameraSettings. Because we want to execute our JavaScript code when our application first launches, we verify that the kind of the activation event is an ActivationKind.Launch event. There is a second conditional within the activated event handler which checks whether an application is being newly launched or whether the application is being resumed from a suspended state. When running a Metro application with Visual Studio, you can use Visual Studio to simulate different application execution states by taking advantage of the Debug toolbar and the new Debug Location toolbar.  Handling the checkpoint Event The default.js file also includes an event handler for the WinJS.Application checkpoint event: app.oncheckpoint = function (eventObject) { // TODO: This application is about to be suspended. Save any state // that needs to persist across suspensions here. You might use the // WinJS.Application.sessionState object, which is automatically // saved and restored across suspension. If you need to complete an // asynchronous operation before your application is suspended, call // eventObject.setPromise(). }; The checkpoint event is raised when your Metro application goes into a suspended state. The idea is that you can save your application data when your application is suspended and reload your application data when your application resumes. Starting the Application The final statement in the default.js file is the statement that gets everything going: app.start(); Events are queued up in a JavaScript array named eventQueue . Until you call the start() method, the events in the queue are not processed. If you don’t call the start() method then the Loaded, Activated, Ready, and Unloaded events are never raised. Summary The goal of this blog entry was to describe the contents of the default.js file which is the JavaScript file which you use to kick off your custom code in a Windows Metro style application written with JavaScript. In this blog entry, I discussed the module pattern, JavaScript strict mode, handling first chance exceptions, WinJS Application events, and activation contexts.

    Read the article

  • Using Dependency Walker

    - by Valter Minute
    Dependency Walker is a very useful tool that can be used to find dependencies of a Portable Executable module. The PE format is used also on Windows CE and this means that Dependency Walker can be used to analyze also Windows CE/Windows Embedded Compact module. On Win32 it can be used also to monitor modules loaded by an application during runtime, this feature is not supported on CE. You can download dependency walker for free here: http://dependencywalker.com/. To analyze the dependencies of a Windows CE/Windows Embedded Compact 7 module you can just open it using Dependency Walker. If you want to check if a specific module can run on a Windows CE/Windows Compact 7 OS Image you can copy the executable in the same directory that contains your OS binaries (FLATRELEASEDIR). In this way Dependency Walker will highlight missing dlls or missing entry points inside existing dlls. Let’s do a quick sample. You need to check if myapp.exe (an application from a third party) can run on an image generated with your Test01 OSDesign. Copy Myapp.exe to the flat release directory of your OS Design. Launch depends.exe and use the File\Open option of its main menu to open the application executable file you just copied. You may receive an error if some of the modules required by your applications are missing. Before you analyze the module dependencies is important to configure Dependency Walker to check DLL in the same folder where your application file is stored. This is needed because some Windows CE DLLs have the same name of Win32 system DLLs but different entry points. To configure the DLL search path select “Options\Configure Module Search Order…” from Depenency Walker main menu. Select “The application directory” from the “Current Search Order” list, select it, and move it to the top of the list using the “Move Up” button. The system will ask to refresh the window contents to reflect your configuration change, click on “Yes” to proceed. Now you can inspect myapp.exe dependencies. Some DLLs are missing (XAMLRUNTIME.DLL and TILEENGINE.DLL) and OLE32.DLL exists but does not export the “CoInitialize” entry point that is required by myapp.exe. The bad news is that MyApp.exe will not run on your OS Image, the good news is that now you know what’s missing and you can add the required modules to your OS Design and fix the problem!

    Read the article

< Previous Page | 569 570 571 572 573 574 575 576 577 578 579 580  | Next Page >