Search Results

Search found 2166 results on 87 pages for 'hot spot'.

Page 59/87 | < Previous Page | 55 56 57 58 59 60 61 62 63 64 65 66  | Next Page >

  • PXE with WDS & Windows Server 2012 - no filename option in DHCP lease?

    - by user1799
    I'm trying to configure Windows Server 2012 (a virtual box VM) with WDS so I can PXE boot some Windows 7 VMs (also virtual box). All the machines involved are only attached to the "host only network", 192.168.56.0/24. The Server 2012 machine has been setup as an AD DS machine, has DNS installed and working along with DHCP with option 60 - PXEClient - set and WDS is set to not listen on DHCP ports. I've followed http://technet.microsoft.com/en-us/library/jj648426.aspx very closely. I've used the boot.wim and install.wim files from the Win 7 installation DVD and they're configured as 'boot' and 'installation' images respectively. When I boot the target machine, it gets an IP address, but I simply get 'no filename' and the boot won't proceed any further. I've tried setting option 66 to 192.168.56.2 (the WDS server) and option 67 to both Boot\x64\wdsnbp.com and Boot\x64\pxeboot.n12 but all to no avail. I can't seem to see anything in the event log, either. Can anyone out there spot what I'm doing wrong? Or give tips to narrow down a diagnostic?

    Read the article

  • How can I make my PCI-E graphics card visible to Ubuntu when the motherboard has integrated graphics

    - by Norman Ramsey
    I have a Gigabyte GA-MA74GM-S2 motherboard with integrated graphics that shows up on lspci as an ATI Radeon 2100. I also bought a PCI-Express Nvidia graphics card so I could use the VDPAU feature on Linux (plays H.264 in hardware). The BIOS has three settings about which display to initialize first: Integrated graphics PCI graphics PCI-Express graphics (PEG) I set the BIOS on PEG, but I cannot get anything, not even a splash screen or POST messages, to emerge from the PCI-Express graphics card. (I'm using a DVI connector; the card also has an HDMI output.) I cannot get the kernel lspci to see the graphics card; the only VGA controller it acknowledges is the integrated one. Running dmidecode acknowledges the existence of an x16 PCI Express slot, and it says Current usage: Unknown There is an additional BIOS setting called "Internal Graphics Mode" which is normally set to "Auto" which means it is supposed to prefer a PCI Express VGA card. I set it to "Disabled" which now means I'm getting no output at all. I will soon be learning how to do a BIOS reset! Other information: The PCI-E card is a MSI N210-MD512H GeForce 210. This is a fanless card. Although there are no fans to see turning, the heat sink on the PCI-E card is definitely getting hot, so the card is getting some sort of power. It gets all its power from the PCI-E slot; there is no external power connector. The BIOS is an AMI Award BIOS. My question: how can I make the PCI Express graphics card visible to Ubuntu?

    Read the article

  • PBS batch jobs - the qalter command

    - by Ryan Budney
    I've got a giant computation running on a Scientific Linux cluster. At present I have over 600 jobs parked in the queue, waiting for processor time, while a few are running. I'm trying to use the qalter command on some of the idle but scheduled jobs. I'd like to schedule them for a later time, so that other users can jump part of the queue, sort of as an act of politeness. Is this doable? For example, JOBNAME 292399 is currently idle, scheduled to be run whenever a spot in the queue opens up. But if I run qalter -a 10051000 292398 followed by qrerun 292398 I get qrerun: Request invalid for state of job 292398.euler. From the qalter documentation, I thought 10051000 refers to tomorrow (oct 5th, 10am) but perhaps I'm misunderstanding something? If I'm going about this the wrong way, please let me know. The main thing I'm looking for is a command that's easily scriptable, so that I can modify when my queued tasks get run. qalter seems good for those purposes if I can get it working. I'd rather avoid running qdel and re qsubbing the computations, as there's a bookkeeping issue on which tasks to restart (vs which ones not to). I want to avoid that kind of bookkeeping. From googling around I notice some qalter commands have rather different date formats, but the above appears to be correct, as far as I can tell from the man docs. Any help would be appreciated.

    Read the article

  • Can't get an IBM xSeries 345 server to load Windows Server 2003 using ServerGuide utility

    - by Kyle Noland
    I have a client that has an IBM xSeries 345 eServer. Per the IBM support website, I have downloaded the ServerGuide Setup 7.4.17 installation ISO and burned a bootable CD. The CD boots fine and loads the utility. I walk through the following screens without any issue: Set the date and Time Detect the IBM ServeRAID card and install the latest firmware Clear the hard disks Set up the RAID array The next step is format the NOS partition. I select my partition size and the utility goes through the following steps: Creating NOS partition Formatting NOS partition (NTFS) Copying W32 files The copying W32 files takes about 10 minutes. I see the CD drive and disks working hard. When the copying is complete, I'm taken to a blank page just NOS Partitioning at the top. At the bottom of the screen are the familiar Back and Exit buttons. I see the place where the Next button should be, and if I click on it I can tell there is something there, but the space is empty. No button is displayed and clicking the empty spot doesn't ever take me to the next screen. I can't load the OS until I get past this part. I have already tried: Burning multiple copies and versions of the ServerGuide CD Letting the final screen just sit there over the weekend thinking it might advance after syncing the drives or something Has anybody else seen this? I'm really at a loss here. EDIT: I found another person who has the exact same problem as me: http://www.ibm.com/developerworks/forums/thread.jspa?messageID=14451763

    Read the article

  • Inter-vlan routing issues

    - by DKNUCKLES
    I've been brought in to help administer a network and I've run into an issue - I'm not sure why this one is beyond me, however I figure an extra set of eyes on the problem may help resolve the issue. I have an HP MSM720 controller and at the time I'm trying to set up a basic hotspot set up with access points. For the time being I'm just looking to have people authenticate with a PSK and access the internet and other resources (namely printers) on other vlans. The user authenticates and the DHCP server on the controller gives them a 192.168.1.0/24 address. They are able to successfully browse the internet and ping machines on other networks, however they are unable to print to network printers that sit on the same LANs as the very computers that wireless clients can ping. The (extremely simplified) topology is as follows Computers on the wireless 192.168.1.1 network are able to ping computers on the 192.168.0.0 network, however cannot ping or print to the printers on the same network. I'm baffled and I have no idea why this is the case. Can anyone shed some light on this for me? Can someone spot the error of my configuration? EDIT : It should be noted that for whatever reason other computers on the 10.0.100.0/24 network cannot even ping the gateway of the Wireless Access network (192.168.1.1) - I'm not sure if this is relevant. These are the VLANS listed on the controller.

    Read the article

  • award phoenix bios not recognizing my sata hdd.

    - by josh
    What am I doing wrong? I have a custom built comp with a Fatal1ty AA8XE mobo. It has 4 SATA ports and one IDE port. When i first got it, I had a really hard time putting in more than one hard drive. Right now i have one 120gb IDE HDD on master and my DVD+-RW on slave connected to the one IDE spot on the mobo. I ripped a bunch of movies and filled up my HDD, so I got a WD 80gb SATA drive. I plugged it into SATA1 and hooked up the power, turned on comp, went into bios. The only thing in any option in any of the menues in this crazy lookin bios is a thing that says "SATA mode". i put it on IDE, set it so PATA is primary, SATA is secondary. booted up my comp, nothin. Not recognizing the SATA. I went back into the bios and checked it all again. I saw that it says SATA2 and SATA4 are the secondaries so i put it on SATA2, booted, nothing, same with SATA4, same with SATA3, all same as SATA1. Bios and wt os are not recognizing the drive as being there at all. I even downloaded and printed the almost 100 page manual for the mobo, read the entire thing, and still can't figure it out. I know there are a lot of people out there smarter than me when it comes to computers. So please, somebody, anybody, please tell me something that I'm not seeing. Some setting somewhere that I didn't configure right. There is something, obviously, but I can't find it. As far as i can tell, everything is set perfectly fine for my 120gb to be the master and the SATA to be the slave. I don't know what I'm doing wrong but I'm seriously about to throw this computer out the window. thankyou in advance to whoever attempts to help.

    Read the article

  • Enabling Hyper-V Integrated Services Time Sync Services versus Internet Time Synchronization

    - by cpuguru
    Should I deselect the "Synchronize with an Internet Time Server" checkbox under the VM's "Date and Time - Internet Time Settings" tab if the "Time Synchronization Service" for a Hyper-V-based Virtual Machine is enabled? One of the Integration Services that Hyper-V provides is the Time Synchronization Service, which can be enabled/disabled by going to a VM's Settings-Integration Services setting in the Management section. I believe this is checked by default. When you install a Windows Server 2008 OS in a VM on the Hyper-V server, it comes with the "Synchronize with an Internet Time Server" option set, pointing to "time.windows.com". I'd think that if the parent Hyper-V server is set to one time server, and the child VM is pointing to a different time server, there would be a momentary blip if the two are not spot on with their times when the synchronization services run. So the question is, which time sync service should I use? I'm assuming not both. And what is the advantage of one over the other? Note: This question assumes that the machines are not joined to a domain. If they were, the machines would also try to update their time against the domain controller with the primary domain controller role too, right? Thanks!

    Read the article

  • ZFS - Impact of L2ARC cache device failure (Nexenta)

    - by ewwhite
    I have an HP ProLiant DL380 G7 server running as a NexentaStor storage unit. The server has 36GB RAM, 2 LSI 9211-8i SAS controllers (no SAS expanders), 2 SAS system drives, 12 SAS data drives, a hot-spare disk, an Intel X25-M L2ARC cache and a DDRdrive PCI ZIL accelerator. This system serves NFS to multiple VMWare hosts. I also have about 90-100GB of deduplicated data on the array. I've had two incidents where performance tanked suddenly, leaving the VM guests and Nexenta SSH/Web consoles inaccessible and requiring a full reboot of the array to restore functionality. In both cases, it was the Intel X-25M L2ARC SSD that failed or was "offlined". NexentaStor failed to alert me on the cache failure, however the general ZFS FMA alert was visible on the (unresponsive) console screen. The zpool status output showed: pool: vol1 state: ONLINE scan: scrub repaired 0 in 0h57m with 0 errors on Sat May 21 05:57:27 2011 config: NAME STATE READ WRITE CKSUM vol1 ONLINE 0 0 0 mirror-0 ONLINE 0 0 0 c8t5000C50031B94409d0 ONLINE 0 0 0 c9t5000C50031BBFE25d0 ONLINE 0 0 0 mirror-1 ONLINE 0 0 0 c10t5000C50031D158FDd0 ONLINE 0 0 0 c11t5000C5002C823045d0 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 c12t5000C50031D91AD1d0 ONLINE 0 0 0 c2t5000C50031D911B9d0 ONLINE 0 0 0 mirror-3 ONLINE 0 0 0 c13t5000C50031BC293Dd0 ONLINE 0 0 0 c14t5000C50031BD208Dd0 ONLINE 0 0 0 mirror-4 ONLINE 0 0 0 c15t5000C50031BBF6F5d0 ONLINE 0 0 0 c16t5000C50031D8CFADd0 ONLINE 0 0 0 mirror-5 ONLINE 0 0 0 c17t5000C50031BC0E01d0 ONLINE 0 0 0 c18t5000C5002C7CCE41d0 ONLINE 0 0 0 logs c19t0d0 ONLINE 0 0 0 cache c6t5001517959467B45d0 FAULTED 2 542 0 too many errors spares c7t5000C50031CB43D9d0 AVAIL errors: No known data errors This did not trigger any alerts from within Nexenta. I was under the impression that an L2ARC failure would not impact the system. But in this case, it surely was the culprit. I've never seen any recommendations to RAID L2ARC. Removing the bad SSD entirely from the server got me back running, but I'm concerned about the impact of the device failure (and maybe the lack of notification from NexentaStor as well). Edit - What's the current best-choice SSD for L2ARC cache applications these days?

    Read the article

  • HA for Resque & Redis

    - by Chris Go
    Trying to avoid SPOFs for Resque and Redis. Ultimately the client is going to be PHP via (https://github.com/chrisboulton/php-resque). After going through and finding some workable HA for nginx+php-fpm and MySQL (mysql master-master setup as a way to simply master-slave promotion), next up is Resque+Redis. Standard install of Resque uses localhost Redis (at DigitalOcean). I am heavily depending on Amazon Route 53 DNS failover to try to solve this. resque1.domain.com points to localhost redis (redis1.domain.com) = same server resque2.domain.com points to localhost redis (redis2.domain.com) = same server Do resque.domain.com with FAILOVER resque1 as primary and resque2 as secondary. What this means is that most of the time (99%), resque1 should be getting hit with resque2 as just a hot backup. This lets me just have to get 2 servers and makes sure that any hits to resque.domain.com goes somewhere The other way to do this is to break out resque and redis into 4 servers and do it as follows resque1.domain.com - redis.domain.com resque2.domain.com - redis.domain.com redis1.domain.com redis2.domain.com Then setup DNS Failover resque.domain.com - primary: resque1 and secondary: resque2 redis.domain.com - primary: redis1 and secondary: redis2 I'd like to get away for 2 servers if I can but is this 2nd setup much better or negligible? Thanks, Chris

    Read the article

  • XSL Template outputting massive chunk of text, rather than HTML. But only on one section

    - by Throlkim
    I'm having a slightly odd situation with an XSL template. Most of it outputs fine, but a certain for-each loop is causing me problems. Here's the XML: <area> <feature type="Hall"> <Heading><![CDATA[Hall]]></Heading> <Para><![CDATA[Communal gardens, pathway leading to PVCu double glazed communal front door to]]></Para> </feature> <feature type="Entrance Hall"> <Heading><![CDATA[Communal Entrance Hall]]></Heading> <Para><![CDATA[Plain ceiling, centre light fitting, fire door through to inner hallway, wood and glazed panelled front door to]]></Para> </feature> <feature type="Inner Hall"> <Heading><![CDATA[Inner Hall]]></Heading> <Para><![CDATA[Plain ceiling with pendant light fitting and covings, security telephone, airing cupboard housing gas boiler serving domestic hot water and central heating, telephone point, storage cupboard housing gas and electric meters, wooden panelled doors off to all rooms.]]></Para> </feature> <feature type="Lounge (Reception)" width="3.05" length="4.57" units="metre"> <Heading><![CDATA[Lounge (Reception)]]></Heading> <Para><![CDATA[15' 6" x 10' 7" (4.72m x 3.23m) Window to the side and rear elevation, papered ceiling with pendant light fitting and covings, two double panelled radiators, power points, wall mounted security entry phone, TV aerial point.]]></Para> </feature> <feature type="Kitchen" width="3.05" length="3.66" units="metre"> <Heading><![CDATA[Kitchen]]></Heading> <Para><![CDATA[12' x 10' (3.66m x 3.05m) Double glazed window to the rear elevation, textured ceiling with strip lighting, range of base and wall units in Beech with brushed aluminium handles, co-ordinated working surfaces with inset stainless steel sink with mixer taps over, co-ordinated tiled splashbacks, gas and electric cooker points, large storage cupboard with shelving, power points.]]></Para> </feature> <feature type="Entrance Porch"> <Heading><![CDATA[Balcony]]></Heading> <Para><![CDATA[Views across the communal South facing garden, wrought iron balustrade.]]></Para> </feature> <feature type="Bedroom" width="3.35" length="3.96" units="metre"> <Heading><![CDATA[Bedroom One]]></Heading> <Para><![CDATA[13' 6" x 11' 5" (4.11m x 3.48m) Double glazed windows to the front and side elevations, papered ceiling with pendant light fittings and covings, single panelled radiator, power points, telephone point, security entry phone.]]></Para> </feature> <feature type="Bedroom" width="3.05" length="3.35" units="metre"> <Heading><![CDATA[Bedroom Two]]></Heading> <Para><![CDATA[11' 4" x 10' 1" (3.45m x 3.07m) Double glazed window to the front elevation, plain ceiling with centre light fitting and covings, power points.]]></Para> </feature> <feature type="bathroom"> <Heading><![CDATA[Bathroom]]></Heading> <Para><![CDATA[Obscure double glazed window to the rear elevation, textured ceiling with centre light fitting and extractor fan, suite in white comprising of low level WC, wall mounted wash hand basin and walk in shower housing 'Triton T80' electric shower, co-ordinated tiled splashbacks.]]></Para> </feature> </area> And here's the section of my template that processes it: <xsl:for-each select="area"> <li> <xsl:for-each select="feature"> <li> <h5> <xsl:value-of select="Heading"/> </h5> <xsl:value-of select="Para"/> </li> </xsl:for-each> </li> </xsl:for-each> And here's the output: Hall Communal gardens, pathway leading to PVCu double glazed communal front door to Communal Entrance Hall Plain ceiling, centre light fitting, fire door through to inner hallway, wood and glazed panelled front door to Inner Hall Plain ceiling with pendant light fitting and covings, security telephone, airing cupboard housing gas boiler serving domestic hot water and central heating, telephone point, storage cupboard housing gas and electric meters, wooden panelled doors off to all rooms. Lounge (Reception) 15' 6" x 10' 7" (4.72m x 3.23m) Window to the side and rear elevation, papered ceiling with pendant light fitting and covings, two double panelled radiators, power points, wall mounted security entry phone, TV aerial point. Kitchen 12' x 10' (3.66m x 3.05m) Double glazed window to the rear elevation, textured ceiling with strip lighting, range of base and wall units in Beech with brushed aluminium handles, co-ordinated working surfaces with inset stainless steel sink with mixer taps over, co-ordinated tiled splashbacks, gas and electric cooker points, large storage cupboard with shelving, power points. Balcony Views across the communal South facing garden, wrought iron balustrade. Bedroom One 13' 6" x 11' 5" (4.11m x 3.48m) Double glazed windows to the front and side elevations, papered ceiling with pendant light fittings and covings, single panelled radiator, power points, telephone point, security entry phone. Bedroom Two 11' 4" x 10' 1" (3.45m x 3.07m) Double glazed window to the front elevation, plain ceiling with centre light fitting and covings, power points. Bathroom Obscure double glazed window to the rear elevation, textured ceiling with centre light fitting and extractor fan, suite in white comprising of low level WC, wall mounted wash hand basin and walk in shower housing 'Triton T80' electric shower, co-ordinated tiled splashbacks. For reference, here's the entire XSLT: http://pastie.org/private/eq4gjvqoc1amg9ynyf6wzg The rest of it all outputs fine - what am I missing from the above section?

    Read the article

  • What's hogging my CPU?

    - by endolith
    Ubuntu's System Monitor applet shows 100% CPU usage continuously. If I click it, the resources tab shows it at 100% continuously, too. If I go to processes, though, to find out which process is the culprit, there is nothing above 10%. If I run top there is nothing above 10%. I try killing lots of things, but it continues at 100%. How can I find out what's hogging the CPU? This is an unusual situation on a computer I use daily, that normally only hits 100% CPU when I'm doing something that requires it (like loading 32 Firefox tabs) after which it goes back to a normal idle level. It's not a new install or anything. It shouldn't be maxed out. I'm not sure when it started or if I changed something that caused it to happen. Normally I would use top or System Monitor and find the process that had gone out of control, but I can't find anything with those tools this time. It persists after reboots and everything. And the processor is obviously hot, so it's not an erroneous reading. Update: I tried killing any process I saw active again, and killing vino-server finally fixed the problem, even though it never went above 5%. I had enabled Remote Desktop a few days ago (and have obviously now disabled it). How did it manage to use 100% CPU while top only showed it as 5% or so? How do I identify the culprit in the future? Looks like I'm not the only one: Still a problem in both jaunty & karmic. Interestingly, both System Monitor & htop do not show the sum of individual processes being anywhere near 100% cpu.

    Read the article

  • Conditionally changing MIME type in nginx

    - by Peter
    I'm using nginx as a frontend to Rails. All pages are cached as .html files on disk, and nginx serves these files if they exist. I want to send the correct MIME type for feeds (application/rss+xml), but the way I have so far is quite ugly, and I'm wondering if there is a cleaner way. Here is my config: location ~ /feed/$ { types {} default_type application/rss+xml; root /var/www/cache/; if (-f request_filename/index.html) { rewrite (.*) $1/index.html break; } if (-f request_filename.html) { rewrite (.*) $1.html break; } if (-f request_filename) { break; } if (!-f request_filename) { proxy_pass http://mongrel; break; } } location / { root /var/www/cache/; if (-f request_filename/index.html) { rewrite (.*) $1/index.html break; } if (-f request_filename.html) { rewrite (.*) $1.html break; } if (-f request_filename) { break; } if (!-f request_filename) { proxy_pass http://mongrel; break; } } My questions: Is there a better way to change the MIME type? All cached files have .html extensions and I cannot change this. Is there a way to factor out the if conditions in /feed/$ and /? I understand that I can use include, but I'm hoping for a better way. Putting part of the config in a different file is not that readable. Can you spot any bugs in the if conditions? I'm using nginx 0.6.32 (Debian Lenny). I prefer to use the version in APT. Thanks.

    Read the article

  • Dell Studio 17 - turning off suddenly

    - by studiohack
    I have a Dell Studio 17 laptop, a refurbished model almost 2 years old...It is currently running Windows 7 32-bit, Home Premium. Via a clean install, it is a Vista upgrade machine...A while back, a problem started to develop while running Vista that it would suddenly just turn off. No warnings, messages, anything. It was like I had the battery out, then just unplugged it from the wall. Just like that. Over several months of this happening (or more), I've observed several things...First, it only seems to happen when I'm doing memory-intensive things, such as watching a online video full screen or running many applications in the background...Second, I can tell when it is about to "flip" as I've termed it, when the fan starts running...the computer gets really hot in places... Anyways, I'm pretty sure this is a hardware problem, because it still exists, even after a Vista-to-7 Upgrade...Is this true? Hardware vs. software? Is there anything I can do to fix this? Is it just a specific component or what? What do you recommend? Thanks!!

    Read the article

  • How to speed up a HP M9517C

    - by Jen
    I bought a system with 8GB RAM, 1TB HD, Quad-Core AMD Phenom 9550, Nvidia Geforce 9300GE, 64-bit Windows Vista Machine. Bought it primarily because it was cheap and came with 25.5 inch screen. Problem: It's slow - if you can believe it. My Dell laptop 1525 is faster and more stable! I tried installing and dual-booting Linux Mint and ran into video and audio troubles. I need fast and stable and I'm going for awesome. Anyone have some suggestions on making this thing smoking hot? Vista is fine, but slows over time - suspect virus/spyware/etc.. But I need to use Photoshop, Fireworks, Dreamweaver, Illustrator. I've tried the alternatives and I just don't like them. When you've got deadlines looming you want to work with what you know. Also use Skype (and I had audio problems with it in Linux), gotomeeting, gotowebinar. Don't need MS Office. Tried VMWare, Virtualbox and again - I keep getting audio/video problems. I'd love someone's input on THEIR setup and how they got there. I'm sure I need to upgrade my video card, but what should I go to?

    Read the article

  • Red Hat 5.3 on HP Proliant DL380 G5 and failed drive on RAID controller

    - by thinkdreams
    I have a development ERP server here in my office that I assist with support on, and originally the DBA requested a single drive setup for some of the drives on the server. Thus the hardware RAID controller (an HP embedded controller) looks like: c0d0 (2 drive) RAID-1 c0d1 (2 drive) RAID-1 c0d2 (1 drive) No RAID <-- Failed c0d3 (1 drive) No RAID c0d4 (1 drive) No RAID c0d5 (1 drive) No RAID c0d2 has failed. I replaced the drive immediately with a spare using the hot-swap, but the c0d2 continues to mark itself as failed, even when I umount the partition. I'm loathe to reboot the server since I'm concerned about the server coming back up in rescue mode but I'm afraid that's the only way to get the system to re-read the drive. I assumed there was some sort of auto-detection routine for this, but I haven't been able to figure out the proper procedure. I have installed the HP ACU CLI utilties, so I can see the hardware RAID setup. I'd really like to find out what the proper procedure should have been, where I went wrong, and how to correct it now. Obviously this goes without saying I should NOT have listened to the DBA and set the drives up as RAID-1 throughout as was my first instinct. He wasn't worried about data loss, but it sure would have been easier to replace the failed drive. :)

    Read the article

  • Increasing SQL Server / Sage performance with SSD? (Dell PE T410)

    - by Anthony
    I have a client wanting better performance of their Sage (Accpac & CRM) server (v5.5, soon to be v7). It's running on 1 of 2 Hyper-V VMs (Svr2008) on a Dell PE T410 server with 24GB of RAM (1333MHz) & dual quad-core, and both VMs (only their C: drives) are on a single RAID5 array. All clients connect via 1Gb ethernet. The 2nd VM is SBS2008 with 9GB RAM (& all SBS dbs & company data are on a separate RAID5 array), & 3GB RAM for the Svr2008 hypervisor. I've given the Sage/SQL Server VM all the RAM I can (12GB) & SQL Server RAM caching (~8GB, never exceeds ~7.5GB, eg. entire db can now be cached in RAM) and that's helped significantly. Upgrading the Hypervisor to Svr2012 is an obvious step, but probably not a dramatic improvement? What about an SSD for this Sage/SQL Server VM (VM = 100GB, <10GB for the actual live DB) ? Can SSDs be put into the SAS hot-swap bays? Or will I have to use the mobo SATA(3Gbps?) ports, or PCI-E SSD card? Should SSDs be RAIDed for this situation? Or is SSD's higher reliability offsetting the need for RAID1/5/10? (I have nightly full disk backups) New territory for me, would appreciate some feedback. Thanks, Anthony.

    Read the article

  • DNS configuration issues. Clients inside network unable to resolve DNS server's name

    - by hydroparadise
    Setup the DNS service on Ubuntu 12.04 64 and all apears to be well except that my dhcp clients do not recognize my DNS servers hostname. When doing a nslookup on one of my Windows clients, I get C:\Users\chad>nslookup Default Server: UnKnown Address: 192.168.1.2 Where I would expect the FQDN in the spot where UnKnown is seen. The DNS server know's itself pretty well, but I think only because I have an entry in the /etc/hosts file to resolve. There's so many places to look I don't even know where to begin. Are there any logs I can look at? Something. Places I've looked at and configured: /etc/bind/zones/domain.com.db /etc/bind/zones/rev.1.168.192.in-addr.arpa /etc/bind/named.conf.local EDIT: '/etc/bind/zones/rev.1.168.192.in-addr.arpa' @ IN SOA dns-serv1.mydomain.com [email protected]. ( 2006081401; 28800; 604800; 604800; 86400 ) IN NS dns-serv1.mydomain.com. 2 IN PTR dns-serv1 2 IN PTR mydomain.com EDIT 2: '/etc/bind/named.conf.local' zone "mydomain.com" { type master; file "/etc/bind/zones/mydomain.com.db"; }; zone "1.168.192.in-addr.arpa" { type master; file "/etc/bind/zones/rev.0.168.192.in-addr.arpa"; };

    Read the article

  • Increasing MSSQL/Sage performance with SSD? (Dell PE T410)

    - by Anthony
    I have a client wanting better performance of their Sage (Accpac & CRM) server (v5.5, soon to be v7). It's running on 1 of 2 Hyper-V VMs (Svr2008) on a Dell PE T410 server with 24GB of RAM (1333MHz) & dual quad-core, and both VMs (only their C: drives) are on a single RAID5 array. All clients connect via 1Gb ethernet. The 2nd VM is SBS2008 with 9GB RAM (& all SBS dbs & company data are on a separate RAID5 array), & 3GB RAM for the Svr2008 hypervisor. I've given the Sage/MSSQL VM all the RAM I can (12GB) & SQL RAM caching (~8GB, never exceeds ~7.5GB, eg. entire db can now be cached in RAM) and that's helped significantly. Upgrading the Hypervisor to Svr2012 is an obvious step, but probably not a dramatic improvement? What about an SSD for this Sage/SQL VM (VM = 100GB, <10GB for the actual live DB) ? Can SSDs be put into the SAS hot-swap bays? Or will I have to use the mobo SATA(3Gbps?) ports, or PCI-E SSD card? Should SSDs be RAIDed for this situation? Or is SSD's higher reliability offsetting the need for RAID1/5/10? (I have nightly full disk backups) New territory for me, would appreciate some feedback. Thanks, Anthony.

    Read the article

  • UPS with a HP Proliant server

    - by Groo
    We placed a EATON Ellipse Max 1500 (900W) as the UPS for our HP Proliant ML350 G6. Upon first power failure (actually we only moved the UPS' input plug to a different socket), server immediatelly turned off, and the Health LED turned red and started blinking. UPS was in operation for about a week before that, with battery fully charged to 100%. Since our server's hot-plug supply is 460W, we are pretty sure we haven't overloaded it, the server was completely idle at that time (no web or win apps running except Windows Server core services). Then we tried to do the same with a different, no-name older PC (Core 2 Duo, 2Gb RAM) with a generic power supply (not sure what the power is) and it continued working when we pulled the plug out. UPS load was less than 15% (measured in the provided Eaton utility). We measured the UPS' output voltage using a smart oscilloscope and the THD of the UPS output waveform turned out to be 40%. Did you have similar experiences? Could this be a faulty UPS? Or a faulty power supply? Or some HP sensors configured to trigger too strictly? I wouldn't like replacing this UPS with the same brand, to get same results. [Edit] I also tried to do this while the server is turned off. While the UPS is working on battery, server will not start - as soon as I press the power button, Health LED starts blinking red.

    Read the article

  • Mountain Lion overheating issue have to do with launchd/Python?

    - by Christopher Jones
    So, Ever since I installed ML, my MacBook Air has been running SUPER hot. Opened up activity monitor, and everything seemed to be pretty normal, until I had it refresh every .5 seconds... and then I started seeing some interesting things. A 'Python' process appears and is terminated several times a second, and uses TONS of CPU 70-110. It's parent process is 'launchd' - and when I sample the process, there is a lot going on with Python. http://db.tt/ovuX3hZM These appear and disappear too quickly to get one... this one only happened to be using 70 ish percent of CPU... but they consistently hit 100-110%. http://db.tt/ovuX3hZMg The parent process... launchd. lots of context switches and UNIX system calls... What is the deal here? (photo goes here when I earn the street cred) The sample of launchd. ANY help here could be of help to not only me, but possibly many others experiencing decreased battery life and warmer laps these days because of this Mountain Lion weirdness. PLEASE HELP! PS - I'd put the screen grabs inline, but i don't have enough street cred yet.

    Read the article

  • Acer Aspire One (mini) mfgd 9/03 locks up also when plugged in

    - by LAURIE ANN
    My problem is almost the same as the Toshiba user (Toshiba A205-5804 freezes when plugged in): Well I have a Toshiba A205-5804 and the problem is that the screen freezes anytime I plug the pc into the external power supply, not as most of the computers having the same issue, my computer DOES freeze in safe mode, and I really can't bear this problem for much longer... It's not an overheat problem, the computer is not getting hot or anything related, I've tried already to change the AC adapter, to boot only with AC and no battery, and also all of these suggestions: The only difference in my case is: I can be using the battery and when it runs down, I can just close the lid and the system goes into hibernation mode. I then plug it in and let it charge. When I think it's finally charged, I can UNPLUG it, open the lid and all is running fine on the battery again. Note: the system was NOT shut down and it still runs as long as I remove the power plug before opening the lid. I have ALL the same issues as the other Toshiba user, also. I was a tech for 9 yrs in my own business and this one has not only stumped me, but anyone I have asked has never heard of this problem. Every repair center wants to charge me for diagnosis, even is they cannot fix it. I would really like to run this system along side of my new Acer Aspire 17" laptop as I need it to finish my grad school work. Any ideas would be GREATLY appreciated. Thanx, Laurie Ann

    Read the article

  • How do i tell if my drivers are up to date on Acer?

    - by joe
    Hoping some kind souls can help me out ? I got a blue screen the other day after trying to load sandboxie. So its obviously conflicting with something. I checked if my drivers were up to date on my acer aspire one AOD270 on this intel based site; http://www.drivermanager.com/en/down...tel&Logo=intel Its showing i have 2 drivers that need updating ; Intel NM10 Express chipset and the Realtek PCIE Cardreader. I have no idea whether to do the update via the Intel Driver update site or the Acer drivers download page? I then ran Bluescreenview and on the dump file its showing ; ''caused by driver'' igdkmd32.sys ''file description'' Intel (R) WDDM Kernel mode driver ''product name''Intel Graphics Accelerator Drivers for Windows 7(R) I bought the laptop here in SE Asia about a year ago. The ''HOT!! NEW download tool'' on the acer drivers site (below) doesnt seem to work and the info about removing and installing drivers is limited. Not sure what to trust on non acer/manufacturer sites. http://support.acer.com/us/en/produc...1&modelId=4040 I've located the igdkmd32.sys file inside the INTEL GRAPHICS MEDIA ACCELERATOR 3600 SERIES 8.14.8.1064. When i click on ''update driver'' in control panel it searches and says its up to date. In windows maintenance it says this intel had a problem, but no solution. For all i know my drivers could be up to date and its something else. Can anybody advise a dummy step by step the process i should follow ? I've never done this before. eg do i delete the old driver first and then download the new one.how much of a problem i could cause by downloading this type of thing wrongly? As yet i havent downloaded any drivers. I've asked on other forums but no luck as yet. Thanks for any help!

    Read the article

  • Server reporting incorrect mime type for css files

    - by Becky
    We have a VPS server that we host our websites on. I have written a CMS using CodeIgniter. On one of the interfaces, I am attempting to upload a css file to the system. This worked correctly when we had it hosted on shared hosting. Since we've moved it to the VPS, I am getting an "incorrect filetype" error. It all comes down to the fact that the server is reporting a mime type of text/x-c for the css file rather than text/css. I logged in via shell and ran the following command on an existing valid css file (to make sure it wasn't an issue with either CodeIgniter or with php). file --brief --mime 'filename.css' 2>&1 The server gave me the following in response to my command: text/x-c; charset=us-ascii My question ... is there some sort of server setting that I need to tweak to get the server to correctly identify the css file as text/css? Do I just have to add a mime type for the css files to the server? I found the mime types file (etc/mime.types), and it just hase video types and a couple other that I have no idea what they are. There is nothing in there for css or images or html files. Unless I'm looking in the wrong spot. I'm not a server person, so I'm hoping someone can help me out. Some server specs: Apache/2.2.22 (Unix) php 5.3.13 Server API = CGI/FastCGI the fileinfo php extension appears to be disabled

    Read the article

  • Moving domain and keeping IMAP email - Linux Evolution, Mac Mail

    - by Douglas Squirrel
    This question is about keeping email during a server move, where the clients are Linux (me) and Mac (my wife) using IMAP. I receive email at [email protected] using a webmail service that my hosting company (1and1) provides. I read it via IMAP in evolution, so I should have copies of all the emails on my local machine. I have just moved mydomain.com from one type of account to another, and the hosting company don't move my existing email on the server when I do this - I assume they move my account to a different mailserver, and don't choose to provide a migration path for the email to move too (yes, this is annoying). Before migrating, I backed up Evolution (File - Backup settings) and did a spot-check in the evolution-backup.tar.gz file to be sure that my mail was in there. After migrating, I restored (File - Restore settings) and had hoped that I would see all my mail again. Unfortunately, Evolution just shows me new mail sent to the account, not the old mail. Is there a way to get the old mail back in the mailserver, or at least displaying in Evolution, as it was before the move? If not, can I read it in some convenient way, e.g. in Evolution offline or in a text file (then I can pick the mails I really want to keep and resend them to myself)? Also, I am about to do a similar move for my wife's domain, [email protected]. She reads her mail on a Mac using IMAP to Apple Mail. Is there anything I can do to make the move smooth for her? (I have backed up [her user]/Library/Mail already, but not sure what to do once the move is done.)

    Read the article

  • Creating Windows 8.1 system image error

    - by Random
    I'm experiencing "not enough space" error when trying to create system image to a USB hard drive: Detailed error: ERROR - A Volume Shadow Copy Service operation error has occurred: (0x8004231f) Insufficient storage available to create either the shadow copy storage file or other shadow copy data. Blah, blah... There is not enough disk space to create the volume shadow copy on the storage location. Make sure that, for all volumes to be backup up, the minimum required disk space for shadow copy creation is available. This applies to both the backup storage destination and volumes included in the backup. Minimum requirement: For volumes less than 500 megabytes, the minimum is 50 megabytes of free space. For volumes more than 500 megabytes, the minimum is 320 megabytes of free space. Recommended: At least 1 gigabyte of free disk space on each volume if volume size is more than 1 gigabyte. ERROR - A Volume Shadow Copy Service operation error has occurred: (0x8004231f) Insufficient storage available to create either the shadow copy storage file or other shadow copy data. I'd tried both - PowerShell wbAdmin start backup -backupTarget:E: -include:C: -allCritical -quiet and via Control Panel - File History button Clearly both EFI and Windows Recovery Environment partitions don't meet requirements coming from System Image tool (pic below) On top of that all system partitions are now shown as 100% free in Disk Management, it's disturbing but far from the actual state. My question is - hot to create System Image in Windows 8.1?

    Read the article

< Previous Page | 55 56 57 58 59 60 61 62 63 64 65 66  | Next Page >