Search Results

Search found 9894 results on 396 pages for 'primary interop assembly'.

Page 59/396 | < Previous Page | 55 56 57 58 59 60 61 62 63 64 65 66  | Next Page >

  • Sending Outlook 2007 Meeting Request with HTML Body

    - by Rick Make
    I know that Outlook.ApointmentItem.Body only supports plain and rich text formats. But my requirement is to send the Appointment with a Html body. Currently I am saving the ApointmentItem as an ics file and attaching it to the e-mail. This works but the outcome that I am looking for is that it is received as a meeting request. I.e. I receive this e-mail I can see the body and have the option to respond to the meeting request. I tried forwarding the AppointmentItem as a vCal but that does not work either. I am I headed in the right direction? Thanks

    Read the article

  • How can I compile some parts of C++/CLI code as Native and some part as Managed?

    - by Usman
    Hello, I am calling LoadTypeLib for loading unmanaged type libraries in C++/CLI. I need to compile some code(some code areas) as managed and some code areas as unmanaged(native) code and form a mixed mode class library as executable. What i need to mention between the lines of code so that whatever the part i need to be compiled as managed should compiled as managed and what part I need to be unmanaged(native) should be compiled as native? Regards Usman

    Read the article

  • From VB6 to .net via COM and Remoting...What a mess!

    - by Robert
    I have some legacy vb6 applications that need to talk to my .Net engine application. The engine provides an interface that can be connected to via .net Remoting. Now I have a stub class library that wraps all of the types that the interface exposes. The purpose of this stub is to translate my .net types into COM-friendly types. When I run this class library as a console application, it is able to connect to the engine, call various methods, and successfully return the wrapped types. The next step in the chain is to allow my VB6 application to call this COM enabled stub. This works fine for my main engine-entry type (IModelFetcher which is wrapped as COM_ModelFetcher). However, when I try and get any of the model fetcher's model types (IClientModel, wrapped as COM_IClientModel, IUserModel, wrapped as COM_IUserModel, e.t.c.), I get the following exception: [Exception - type: System.InvalidCastException 'Return argument has an invalid type.'] in mscorlib at System.Runtime.Remoting.Proxies.RealProxy.ValidateReturnArg(Object arg, Type paramType) at System.Runtime.Remoting.Proxies.RealProxy.PropagateOutParameters(IMessage msg, Object[] outArgs, Object returnValue) at System.Runtime.Remoting.Proxies.RealProxy.HandleReturnMessage(IMessage reqMsg, IMessage retMsg) at System.Runtime.Remoting.Proxies.RealProxy.PrivateInvoke(MessageData& msgData, Int32 type) at AWT.Common.AWTEngineInterface.IModelFetcher.get_ClientModel() at AWT.Common.AWTEngineCOMInterface.COM_ModelFetcher.GetClientModel() The first thing I did when I saw this was to handle the 'AppDomain.CurrentDomain.AssemblyResolve' event, and this allowed me to load the required assemblies. However, I'm still getting this exception now. My AssemblyResolve event handler is loading three assemblies correctly, and I can confirm that it does not get called prior to this exception. Can someone help me untie myself from this mess of interprocess communication?!

    Read the article

  • WindowsIdentity Token in Legacy ASP

    - by Max Schmeling
    I've created a .Net library at work that is used by all of our developers. The security part of it uses Microsoft AzMan for the security backend. In order to create a security (AzMan) ClientContext I have to pass it a token value (as a uint). This is all fine an dandy until I needed to make a COM wrapper for our common library so some of our legacy pages could take advantage of it without being rewritten for now. I cannot figure out how to get the token value to pass to AzMan from legacy ASP. The COM wrapper is setup to run as a COM Server and runs as a specific user that we use here for all COM objects, therefor the common library can't just pull the identity using .Net. Any ideas?

    Read the article

  • Invoke a COM addin option from VBA

    - by rip
    Can I invoke an option on a COM Add-in from a VBA macro in Word or Excel 2007? The COM Add-in was written using VSTO – it adds a custom ribbon tab with a number of options that I want to execute from a VBA macro. I can reference the add-in using Application.COMAddIns("MyAddinName") but I can’t find an option to invoke an option. I’ve also played around with the Application.CommandBars collection, and can see that you can execute an option using CommandBarControl.Execute but I can’t find my command bar in the Application.CommandBars collection. Does anyone know if this is possible?

    Read the article

  • WinAPI magic and MONO runtime

    - by Luca
    I'm trying to get the same result of a .NET application (see the link Hide TabControl buttons to manage stacked Panel controls for details), but using the MONO runtime instead of the MS .NET runtime. Pratically, when the custom control is executed using the MONO runtime, the underlying message is not sent to the control, causing the tab pages to be shown... Is there a portable solution which is elegant as the linked one? If it is not possible, what are possible workarounds (apart from removing/adding tabs at runtime)?

    Read the article

  • Need to call COM component using reflection in .NET

    - by Usman
    I need to determine the COM component(unmanaged code) type and invoke the exposed interface's methods using reflection in C# at runtime. First What member of "Type" tells that type is COM component and we can take CLSID at runtime? Is Type.COMObject? I need to call methods of exposed interfaces as they called in unmanaged code using CoCreateInstance by passing CLSID and REFID ... I am using InvokeMember but it returns null or 0 as out parameter. How to pass out parameter in this case.? Is there any need to pass out parameter? As all my COM unmanaged code suppose to take last parameter as an OUT parameter and after executing it puts the result into that out param. But I've converted all my unmanaged COM code to .NET managed assemblies using tlbimp.exe.

    Read the article

  • ExecutionEngineException thrown when loading native dll

    - by Axarydax
    I have a 32-bit .net application that uses a native 32-bit DLL via DllImport(). The native DLL is our internal file analysis library, and I need to use it as porting it to C# would be a problem if people update it (other software uses it). The problem is that when I try to execute any method in the native DLL I get a System.ExecutionEngineException thrown. In fact, I've reduced the managed application to a simple tester that just calls a native method, but it still fails. I am on 64-bit Windows 7, but that should not matter as I'm compiling everything as 32-bit binaries. What is also interesting, when I look at the native DLL in the Dependency Walker, it shows that it can't find msvcr90.dll - but when I open any other of our native DLLs in the Dependency Walker, it can find their referenced msvcr90.dll just fine. Can there by some wrongness in the compilation of native DLL that messes up its DLL references?

    Read the article

  • ExecutionEngineException thrown when loading native dll in c#

    - by Axarydax
    Hi there. I have a 32-bit .net application that uses a native 32-bit DLL via DllImport(). The native DLL is our internal file analysis library, and I need to use it as porting it to C# would be a problem if people update it (other software uses it). The problem is that when I try to execute any method in the native DLL I get a System.ExecutionEngineException thrown. In fact, I've reduced the managed application to a simple tester that just calls a native method, but it still fails. I am on 64-bit Windows 7, but that should not matter as I'm compiling everything as 32-bit binaries. What is also interesting, when I look at the native DLL in the Dependency Walker, it shows that it can't find msvcr90.dll - but when I open any other of our native DLLs in the Dependency Walker, it can find their referenced msvcr90.dll just fine. Can there by some wrongness in the compilation of native DLL that messss up its DLL references?

    Read the article

  • Producing Mini Dumps for _caught_ SEH exceptions in mixed code DLL

    - by Assaf Lavie
    I'm trying to use code similar to clrdump to create mini dumps in my managed process. This managed process invokes C++/CLI code which invokes some native C++ static lib code, wherein SEH exceptions may be thrown (e.g. the occasional access violation). C# WinForms -> C++/CLI DLL -> Static C++ Lib -> ACCESS VIOLATION Our policy is to produce mini dumps for all SEH exceptions (caught & uncaught) and then translate them to C++ exceptions to be handled by application code. This works for purely native processes just fine; but when the application is a C# application - not so much. The only way I see to produce dumps from SEH exceptions in a C# process is to not catch them - and then, as unhandled exceptions, use the Application.ThreadException handler to create a mini dump. The alternative is to let the CLR translate the SEH exception into a .Net exception and catch it (e.g. System.AccessViolationException) - but that would mean no dump is created, and information is lost (stack trace information in Exception isn't as rich as the mini dump). So how can I handle SEH exceptions by both creating a minidump and translating the exception into a .Net exception so that my application may try to recover?

    Read the article

  • Making a COM dll to be invoked from c#, HRESULT error handling?

    - by Daniel
    I'm making a COM interface that c# will be using, however i am wondering how i am to check for errors and exception handling on the c# end as at the moment i am just returning a HRESTULT or bool for most methods. But several things can go wrong in some of these methods and returning a E_FAIL just doesn't cut it. What can i do in order to return more information? Can i make a HRESULT of my own?

    Read the article

  • Excel Object in asp.net

    - by Xyz
    Hi I have a serious issue. I am using excel object for opening the excel file it works fine i my PC. when i make application as a website and running the page and uploading it gives the error "'C:\Documents and Settings\Administrator\Desktop\Work\SABRE MSO Mapping Request Template.xlsx' could not be found. Check the spelling of the file name, and verify that the file location is correct. If you are trying to open the file from your list of most recently used files, make sure that the file has not been renamed, moved, or deleted. ". I think it taking server path...but i want to open client excel file before saving the file to the server. Plz help.

    Read the article

  • Calling a running C# application from VBA

    - by Robert
    I have some VBA code that needs to talk to a running c# application. For what it's worth, the c# application runs as a service, and exposes an interface via .net remoting. I posted a question regarding a specific problem I'm having already (http://stackoverflow.com/questions/2556163/from-vb6-to-net-via-com-and-remoting-what-a-mess) but I think I may have my structure all wrong... So I'm taking a step back - what's the best way to go about doing this? One thing that's worth taking into account is that I want to call into the running application - not just call a precompiled DLL...

    Read the article

  • Foreign keys and pagination

    - by whitstone86
    This is my pagination script: <?php /*********************************** * PhpMyCoder Paginator * * Created By PhpMyCoder * * 2010 PhpMyCoder * * ------------------------------- * * You may use this code as long * * as this notice stays intact and * * the proper credit is given to * * the author. * ***********************************/ ?> <head> <title> Pagination Test - Created By PhpMyCoder</title> <style type="text/css"> #nav { font: normal 13px/14px Arial, Helvetica, sans-serif; margin: 2px 0; } #nav a { background: #EEE; border: 1px solid #DDD; color: #000080; padding: 1px 7px; text-decoration: none; } #nav strong { background: #000080; border: 1px solid #DDD; color: #FFF; font-weight: normal; padding: 1px 7px; } #nav span { background: #FFF; border: 1px solid #DDD; color: #999; padding: 1px 7px; } </style> </head> <?php //Require the file that contains the required classes include("pmcPagination.php"); //PhpMyCoder Paginator $paginator = new pmcPagination(20, "page"); //Connect to the database mysql_connect("localhost","root","PASSWORD"); //Select DB mysql_select_db("tvguide"); //Select only results for today and future $result = mysql_query("SELECT programme, channel, airdate, expiration, episode, setreminder FROM epdata1 where airdate >= now() order by expiration GROUP BY airdate"); //You can also add reuslts to paginate here mysql_data_seek($queryresult,0) ; while($row = mysql_fetch_array($result)) { $paginator->add(new paginationData($row['programme'], $row['channel'], $row['airdate'], $row['expiration'], $row['episode'], $row['setreminder'])); } ?> <?php //Show the paginated results $paginator->paginate (); ?><? include("pca-footer1.php"); ?> <?php //Show the navigation $paginator->navigation(); ?> However, I have two tables in this, and they are epdata1 (where the airtimes for my show House M.D. are) and housemdep plus the setreminder table. How can I use foreign keys in relation to this? I'm not sure if this will work for my script, but am willing to try. What I would like to do is to select certain episodes from the table housemdep (episodes of the show) and if any are selected it shows them as this: House M.D. showing on Channel 1 June 6th - 8:00pm "Wilson" Set Reminder House M.D. showing on Channel 1 June 7th - 1:30am "Wilson" Set Reminder House M.D. showing on Channel 1 June 7th - 12:55pm "House's Head" Set Reminder or like this, if I have not selected an episode from the row: House M.D. showing on Channel 1 June 7th - 8:00pm "House's Head" Set Reminder House M.D. showing on Channel 1 June 8th - 9:00pm Set Reminder House M.D. showing on Channel 1 June 9th - 2:30pm Set Reminder House M.D. showing on Channel 1 June 7th - 8:00pm "Que Sera Sera" Set Reminder Foreign keys and relationship of interlinked tables are new to me, if anyone could help I'd appreciate this. I've tried some of what Google suggested on foreign keys in another version of this script (this is a clone of the original on my localhost server running Apache and PHP 5.28/MySQL), but am not sure how to implement this. Thanks.

    Read the article

  • How to obtain the native stacktrace from native exceptions caught in managed code

    - by aaa
    I have some managed code that calls to a method inside some native DLL(i have the appropriate symbol files). Sometimes, that native method throws an exception which I catch in my managed code. However, when i print the stacktrace from my caught exception, I see only managed code (the last frame is the call to the native code .. but it don't see the stacktrack within the native code). How can I obtain the native callstack as well? *When i'm debugging the code, i am able to step into the native code, and see the actuall call stack.

    Read the article

  • How to check name of Domino Server to which lotus notes is configured? using C#

    - by Preeti
    Hi, I am trying to login Domino server. For that i am taking Lotus Notes Password and Domino Server Name from user. if (notesPassword == "" && serverName == "") { MessageBox.Show("Please enter the server name !! "); return; } else { if (connectToDomino(notesPassword, serverName)) { MessageBox.Show("Connection Established Succesfully!!.."); } else { MessageBox.Show("Connection Fail.Please Login Again To Begin"); } }//else and in public bool connectToDomino(string NotesPassword, string strDominoServerName) { try { if (_lotesNotesSession == null) { NotesSession notesSession = new Domino.NotesSessionClass(); notesSession.Initialize(NotesPassword); } return true; } catch(Exception ex) { return false; } } Here i am initializing notes password.So in this case it is just verifying Notes Password. So even if user enters invalid entry of server name above function will return true. I tried : string serverName = notesSession.ServerName; But it is showing null value. :( Regards, Preeti

    Read the article

  • Strange behaviour using Drag and Drop in word 2003 automation in headers

    - by Oliver Hanappi
    Hi! I am developing a template based addin for Word 2003 which allows the user to drag and drop elements from a listbox into the word document. Unfortunately I'm getting a really strange behaviour when trying to drop elements in the document's header. Open the template and type something in the header Close the header and insert some content on the page Add a page break. Switch to page layout mode where and set zoom level to "Two Pages" Open the header Slowly Drag and Drop an list item from the list box to the header. See multiple Page Setups dialogs occur which cause Word to crash. Here is my code: // in ThisDocument.cs public MyUserControl _control; public void Init() { _control = new MyUserControl(); ActionsPane.Controls.Add(_control); ActionsPane.Visible = true; } // in MyUserControl.cs public void listBox1_MouseDown(object sender, MouseEventArgs e) { DoDragDrop("something", DragDropEffects.Copy); } Have I done somethinkg wrong with implementing Drag and Drop? Is there a workaround for this strange behaviour? Thanks in advance, Oliver Hanappi

    Read the article

  • Why would you need to run regasm and caspol on a .net component more than once?

    - by Craig Johnston
    Why would you need to run regasm and caspol on a .NET component more than once? I have a COM client that uses a .NET component residing on another machine. Consequently I need to run regasm and caspol on this .NET component. What could cause there to be the need to do this again on the same machine to the same component? Is the effect of regasm and caspol only temporary? Or can I assume that someone has reset or cleared something on a machine if I am having to do this again?

    Read the article

  • Blittable Value Types

    - by Michael Covelli
    Here is a list of blittable types. It contains Int32 and Int64. But I don't see just plain "int" on the list. How does C# treat the plain "int" type? Does it just get replaced with Int32 or Int64 depending on the system? Or is there a subtle difference? Will using "int" ever cause a performance hit for marshalling?

    Read the article

  • Parsing a .NET DataSet returned from a .NET Web Service in Java

    - by Chris Dail
    I have to consume a .NET hosted web service from a Java application. Interoperability between the two is usually very good. The problem I'm running into is that the .NET application developer chose to expose data using the .NET DataSet object. There are lots of articles written as to why you should not do this and how it makes interoperability difficult: http://www.hanselman.com/blog/ReturningDataSetsFromWebServicesIsTheSpawnOfSatanAndRepresentsAllThatIsTrulyEvilInTheWorld.aspx http://www.lhotka.net/weblog/ThoughtsOnPassingDataSetObjectsViaWebServices.aspx http://aspnet.4guysfromrolla.com/articles/051805-1.aspx http://www.theserverside.net/tt/articles/showarticle.tss?id=Top5WSMistakes My problem is that despite this not being recommended practice, I am stuck with having to consume a web service returning a DataSet with Java. When you generate a proxy for something like this with anything other than .NET you basically end up with an object that looks like this: @XmlElement(namespace = "http://www.w3.org/2001/XMLSchema", required = true) protected Schema schema; @XmlAnyElement(lax = true) protected Object any; This first field is the actual schema that should describe the DataSet. When I process this using JAX-WS and JAXB in Java, it bring all of XS-Schema in as Java objects to be represented here. Walking the object tree of JAXB is possible but not pretty. The any field represents the raw XML for the DataSet that is in the schema specified by the schema. The structure of the dataset is pretty consistent but the data types do change. I need access to the type information and the schema does vary from call to call. I've though of a few options but none seem like 'good' options. Trying to generate Java objects from the schema using JAXB at runtime seems to be a bad idea. This would be way too slow since it would need to happen everytime. Brute force walk the schema tree using the JAXB objects that JAX-WS brought in. Maybe instead of using JAXB to parse the schema it would be easier to deal with it as XML and use XPath to try and find the type information I need. Are there other options I have not considered? Is there a Java library to parse DataSet objects easily? What have other people done who may have similar situations?

    Read the article

  • Access COM object through a windows process handle.

    - by Sivvy
    I'm currently automating an application at work using COM, and have an issue where anyone using my application has a problem if the original application is already open when my application runs. I know how to locate the process if it's open, but instead of having to worry about closing it, or working around it, etc., I want to try to use the existing application instead of opening a new one. This is how I normally start the application in my automation program: Designer.Application desApp = new Designer.Application(); Now I'm attempting to try and use the handle from an existing application: Designer.Application desApp = (Designer.Application)((System.Diagnostics.Process.GetProcessesByName("Designer.exe")[0]).Handle) (I know this doesn't work, since .Handle returns an IntPtr, but I'm using it as an example.) Is there any way to accomplish this? How do I return a usable object if I know the handle/process?

    Read the article

  • How to declare and implement a COM interface on C# that inherits from another COM interface?

    - by Carlos Loth
    I'm trying to understand what is the correct why to implement COM interfaces from C# code. It is straightforward when the interface doesn't inherit from other base interface. Like this one: [ComImport, Guid("2047E320-F2A9-11CE-AE65-08002B2E1262"), InterfaceType(ComInterfaceType.InterfaceIsIUnknown)] public interface IShellFolderViewCB { long MessageSFVCB(uint uMsg, int wParam, int lParam); } However things start to become weired when I need to implement an interface that inherits from other COM interfaces. For example, if I implement the IPersistFolder2 interface which inherits from IPersistFolder which inherits from IPersist as I usually on C# code: [ComImport, Guid("0000010c-0000-0000-C000-000000000046"), InterfaceType(ComInterfaceType.InterfaceIsIUnknown)] public interface IPersist { void GetClassID([Out] out Guid classID); } [ComImport, Guid("000214EA-0000-0000-C000-000000000046"), InterfaceType(ComInterfaceType.InterfaceIsIUnknown)] public interface IPersistFolder : IPersist { void Initialize([In] IntPtr pidl); } [ComImport, Guid("1AC3D9F0-175C-11d1-95BE-00609797EA4F"), InterfaceType(ComInterfaceType.InterfaceIsIUnknown)] public interface IPersistFolder2 : IPersistFolder { void GetCurFolder([Out] out IntPtr ppidl); } The operating system is not able to call the methods on my object implementation. When I'm debugging I can see the constructor of my IPersistFolder2 implementation is called many times, however the interface methods I've implemented aren't called. I'm implementing the IPersistFolder2 as follows: [Guid("A4603CDB-EC86-4E40-80FE-25D5F5FA467D")] public class PersistFolder: IPersistFolder2 { void IPersistFolder2.GetClassID(ref Guid classID) { ... } void IPersistFolder2.Initialize(IntPtr pidl) { ... } void IPersistFolder2.GetCurFolder(out IntPtr ppidl) { ... } } What seems strange is when I declare the COM interface imports as follow, it works: [ComImport, Guid("0000010c-0000-0000-C000-000000000046"), InterfaceType(ComInterfaceType.InterfaceIsIUnknown)] internal interface IPersist { void GetClassID([Out] out Guid classID); } [ComImport, Guid("000214EA-0000-0000-C000-000000000046"), InterfaceType(ComInterfaceType.InterfaceIsIUnknown)] internal interface IPersistFolder : IPersist { new void GetClassID([Out] out Guid classID); void Initialize([In] IntPtr pidl); } [ComImport, Guid("1AC3D9F0-175C-11d1-95BE-00609797EA4F"), InterfaceType(ComInterfaceType.InterfaceIsIUnknown)] internal interface IPersistFolder2 : IPersistFolder { new void GetClassID([Out] out Guid classID); new void Initialize([In] IntPtr pidl); void GetCurFolder([Out] out IntPtr ppidl); } I don't know why it works when I declare the COM interfaces that way (hidding the base interface methods using new). Maybe it is related to the way IUnknown works. Does anyone know what is the correct way of implementing COM interfaces in C# that inherits from other COM interfaces and why?

    Read the article

  • Using TaskDialogIndirect in C#

    - by Dennis Delimarsky
    I've been working for a while with the regular Windows Vista/7 TaskDialog for a while, and I wanted to add some additional functionality (like custom buttons and a footer), so I need to use TaskDialogIndirect. Following the MSDN documentation for TaskDialogIndirect, I got this signature: [DllImport("comctl32.dll",CharSet = CharSet.Unicode,EntryPoint="TaskDialogIndirect")] static extern int TaskDialogIndirect (TASKDIALOGCONFIG pTaskConfig, out int pnButton, out int pnRadioButton, out bool pfVerificationFlagChecked); The TASKDIALOGCONFIG class is shown below: public class TASKDIALOGCONFIG { public UInt16 cbSize; public IntPtr hwndParent; public IntPtr hInstance; public String dwFlags; public String dwCommonButtons; public IntPtr hMainIcon; public String pszMainIcon; public String pszMainInstruction; public String pszContent; public UInt16 cButtons; public TASKDIALOG_BUTTON pButtons; public int nDefaultButton; public UInt16 cRadioButtons; public TASKDIALOG_BUTTON pRadioButtons; public int nDefaultRadioButton; public String pszVerificationText; public String pszExpandedInformation; public String pszExpandedControlText; public String pszCollapsedControlText; public IntPtr hFooterIcon; public IntPtr pszFooterText; public String pszFooter; // pfCallback; // lpCallbackData; public UInt16 cxWidth; } The TASKDIALOG_BUTTON implementation: public class TASKDIALOG_BUTTON { public int nButtonID; public String pszButtonText; } I am not entirely sure if I am on the right track here. Did anyone use TaskDialogIndirect from managed code directly through WinAPI (without VistaBridge or Windows API Code Pack)? I am curious about the possible implementations, as well as the callback declarations (I am not entirely sure how to implement TaskDialogCallbackProc). PS: I am looking for a direct WinAPI implementation, not one through a wrapper.

    Read the article

< Previous Page | 55 56 57 58 59 60 61 62 63 64 65 66  | Next Page >