Search Results

Search found 194 results on 8 pages for 'duncan watts'.

Page 6/8 | < Previous Page | 2 3 4 5 6 7 8  | Next Page >

  • TFS 2010 build template failing to open in designer - how to fix?

    - by Duncan Bayne
    I can open the DefaultTemplate.xaml that was installed as part of our TFS 2010 RC setup. I created a copy of this template called ApplicationTemplate.xaml and modified it slightly, using the workflow designer in Visual Studio. Now, I can no longer open ApplicationTemplate.xaml. When I try, I receive many errors like the following: Error 2 Assembly 'Microsoft.TeamFoundation.Build.Client' was not found. Verify that you are not missing an assembly reference. Also, verify that your project and all referenced assemblies have been built. C:\Projects\tfs\Hydraulics\BuildProcessTemplates\ApplicationTemplate.xaml 1 1828 Miscellaneous Files However, I can still open and edit the DefaultTemplate.xaml file without any issues. Has anyone else come across this problem, & if so, did you manage to resolve it or did you have to recreate the template?

    Read the article

  • Need to allocate memory before a Delphi string copy?

    - by Duncan
    Do I need to allocate memory when performing a Delphi string copy? I've a function which posts a Windows message to another form in my application. It looks something like this: // Note: PThreadMessage = ^TThreadMessage; TThreadMessage = String; function PostMyMessage( aStr : string ); var gMsgPtr : PThreadMessage; gStrLen : Integer; begin New(gMsgPtr); gStrLen := StrLen(PWideChar(aMsg)); gMsgPtr^ := Copy(aMsg, 0, gStrLen); PostMessage(ParentHandle, WM_LOGFILE, aLevel, Integer(gMsgPtr)); // Prevent Delphi from freeing this memory before consumed. LParam(gMsgPtr) := 0; end;

    Read the article

  • Which PHP framework is closest to Ruby on Rails? CakePHP? CodeIgniter?

    - by Mike Duncan
    I'm going to be switching back and forth between Ruby on Rails projects and some as-of-yet undecided PHP MVC framework projects. Which of the PHP MVC frameworks out there (CakePHP, CodeIgniter?, others?) is most similar to Ruby on Rails in that the most conventions, locations, workflows, etc are preserved? I'm looking for the similarity in the way things are done such as directory structures, conventions, etc, not a pros vs cons in speed, extra features, etc.

    Read the article

  • Select statement to check multiple rows against 2 variables

    - by Duncan Cook
    I have the following table : alertID inspectorID datelive dateread 1 none 2012-11-06 10:36:03.350 NULL 2 none 2012-11-06 10:36:25.043 NULL 3 none 2012-11-06 10:36:42.433 NULL 1 31030 2012-11-06 10:37:19.193 2012-06-11 10:34:47.000 I want to select the alerts that dont have the inspectors ID against it AND where the alert ID doenst match the one that has the inspectorID against it, ie inspector has read alert 1 so i only want it to return alerts 2 & 3 Am using Classic ASP and MS-SQL Cheers

    Read the article

  • PHP: Auto Updating subscriptions?

    - by Duncan Palmer
    Hey guys I am currently making a website and I am hopefully going to start a premium service for it. What I am currently looking into right now is how to make an "auto updating" shop which removes 1 day from how many days left the user has left on their premium status. so for example if the users purchases 30 days of premium, each day that 30 with negate 1 so.. 30, 29, 28, 27.. etc and then if the days gets to 0 in will remove premium status. The only way I can think of keeping track of this right now is by manually monitoring each persons premium status but that wouldnt be very practical. What would the best way for me to do this? (hopefully "automatically") Thanks.

    Read the article

  • How to handle ids and polymorphic associations in views if compound keys are not supported?

    - by duncan
    I have a Movie plan table: movie_plans (id, description) Each plan has items, which describe a sequence of movies and the duration in minutes: movie_plan_items (id, movie_plan_id, movie_id, start_minutes, end_minutes) A specific instance of that plan happens in: movie_schedules (id, movie_plan_id, start_at) However the schedule items can be calculated from the movie_plan_items and the schedule start time by adding the minutes create view movie_schedule_items as select CONCAT(p.id, '-', s.id) as id, s.id as movie_schedule_id, p.id as movie_plan_item_id, p.movie_id, p.movie_plan_id, (s.start_at + INTERVAL p.start_minutes MINUTE) as start_at, (s.start_at + INTERVAL p.end_minutes MINUTE) as end_at from movie_plan_items p, movie_schedules s where s.movie_plan_id=p.movie_plan_id; I have a model over this view (readonly), it works ok, except that the id is right now a string. I now want to add a polymorphic property (like comments) to various of the previous tables. Therefore for movie_schedule_items I need a unique and persistent numeric id. I have the following dilemma: I could avoid the id and have movie_schedule_items just use the movie_plan_id and movie_schedule_id as a compound key, as it should. But Rails sucks in this regard. I could create an id using String#hash or a md5, thus making it slower or collision prone (and IIRC String#hash is no longer persistent across processes in Ruby 1.9) Any ideas on how to handle this situation?

    Read the article

  • Regarding C typedef struct

    - by Bruce Duncan
    I have multiple instances of typedef struct box so box box1, box box2 etc. The members of the struct are length, width, height etc. typedef struct { int width; int height; } box; box box1; box box2; How can I create a function that operates on all the width members of each box instance? My confusion is how do I pass a pointer to a typedef struct member that works across all instances of box. I know how to pass a pointer to a specific instance member like box1.width but how to pass .width and then do box1.width=value; box2.width=value; box3.width=value; within the function?

    Read the article

  • Send a String[] ArrayList over Socket connection

    - by Duncan Palmer
    So i'm trying to send a String[] Array/List over an open socket connection. I currently have this code: Sending: public void sendData() { try { OutputStream socketStream = socket.getOutputStream(); ObjectOutputStream objectOutput = new ObjectOutputStream(socketStream); objectOutput.writeObject(new String[] {"Test", "Test2", "Test3"}); objectOutput.close(); socketStream.close(); } catch (Exception e) { System.out.println(e.toString()); } } Recieving: public Object readData() { try { InputStream socketStream = socket.getInputStream(); ObjectInputStream objectInput = new ObjectInputStream(new GZIPInputStream(socketStream)); Object a = objectInput.readObject(); return a; } catch(Exception e) { return null; } } After I have recieved the String array/list on the other end I want to be able to iterate through it like I would do normally so I can get the values. My current code doesn't seem to works as it returns null as the value. is this possible?

    Read the article

  • Can anyone explain these differences between two similar i7 processors? [closed]

    - by Brian Frost
    I have two systems I've just built. They both have i7 processors and Asus P8Z77 motherboards. When I run a simple processor loop benchmark that I wrote in Delphi some time back I get one machine showing nealry twice as fast as the other. I then used CPU-Z to dump me the details of the hardware and I see that the fast machine shows: Processor 1 ID = 0 Number of cores 4 (max 8) Number of threads 8 (max 16) Name Intel Core i7 2700K Codename Sandy Bridge Specification Intel(R) Core(TM) i7-2700K CPU @ 3.50GHz Package (platform ID) Socket 1155 LGA (0x1) CPUID 6.A.7 Extended CPUID 6.2A Core Stepping D2 Technology 32 nm TDP Limit 95 Watts Core Speed 3610.7 MHz Multiplier x FSB 36.0 x 100.3 MHz Stock frequency 3500 MHz the slow machine shows: Processor 1 ID = 0 Number of cores 4 (max 8) Number of threads 8 (max 16) Name Intel Core i7 2600K Codename Sandy Bridge Specification Intel(R) Core(TM) i7-2600K CPU @ 3.40GHz Package (platform ID) Socket 1155 LGA (0x1) CPUID 6.A.7 Extended CPUID 6.2A Core Stepping D2 Technology 32 nm TDP Limit 95 Watts Core Speed 1648.2 MHz Multiplier x FSB 16.0 x 103.0 MHz Stock frequency 3400 MHz i.e the slow machine has a 2600k to the fast machine 2700k. The very different "Multiplier x FSB" must be significant but I dont understand how two processors with a very 'similar' number can be so different. To get the machines the same must I copy the processors or is there some clever setting that I can change? Thanks for any help. Brian.

    Read the article

  • UPS power requirements for server

    - by captainentropy
    Greetings! So, I just placed an order for a new server. The company recommended that I get a 3000W UPS. (!) As best as I could I calculated the following wattage consumption based on benchmarked data or datasheets provided by the manufacturers of each component: number watts **total watts** MoBo 1 240 240 CPUs (E5540) 2 80 160 RAID cards (3ware) 2 18 36 RAM (6x4GB) 6 3 18 DVD drive 1 7 7 floppy 1 2 2 RE4 drives 8 7 56 WD20 drives 8 6 48 Intel X25 SSD 2 0.15 0.3 total = 567 So that is for the PSU requirements only. The PSUs in the machine are a 720W for the master node and 800W each for two subsystems. That's a total of 2320W that can be delivered by these PSUs. But that is 4X the amount being consumed, at most, by the components. I didn't count case fans or the eSATA card (3W maybe?) or what the PSUs themselves require but assuming I double or triple my calculations I'm not even remotely close to the 3000W UPS I was suggested to get. They run at least $1100. I could get a 2000W for about $750 or a 1500W for $450 and still be well over my estimated power need. I don't think I need a whole lot of run time in the case of a power outage, maybe 20 minutes max, enough time to shutdown if the power doesn't come on within 5-10 minutes. Any thoughts? Am I off on my calculations? Did I overlook something major? If so what are your suggestions for a UPS? Thanks!

    Read the article

  • Recommendation for a redundant 60V DC Powersupply

    - by Lairsdragon
    We have some Telco-Equipment in our data space center which we had been given by our Telco. What they didn't provide is a redundant power supply and therefore we are struggling with outages of this equipment. What I am searching for is a redundant Power-Supply for 60V and 600W 60 Volt DC output 600 Watts rated power 2 220V Input with galvanic separation Rack mountable Any suggestions?

    Read the article

  • Bladecenter-E Power Module fault

    - by Lihnjo
    We have problem on IBM Bladecenter-E Critical Events Power module 2 is off. DC fault. Power module 4 is off. DC fault. Warnings and System Events Insufficient chassis power to support redundancy What is the best solution for this problem? Thanks AMM Service Data Help SPAPP Capture Available 10/13/2010 17:03:47 1090347 bytes Time: 11/19/2012 11:02:31 UUID: 42E1 5D2F D7BF 41A6 A4A2 48D1 3FB7 0540 MAC Address xx:xx:xx:xx:xx:xx MM Information Name: nnnnn Contact: aaa, bbb, ccc, England Location: [email protected] IP address: 111.222.333.444 Date Time Information GMT offset: +1:00 - Central Europe Time (Western Europe, Algeria, Nigeria, Angola) Adjust for DST: Yes NTP: Enabled NTP Hostname/IP: 111.222.333.444 System Health: Critical System Status Summary One or more monitored parameters are abnormal. Critical Events Power module 2 is off. DC fault. Power module 4 is off. DC fault. Warnings and System Events Insufficient chassis power to support redundancy CHASSIS (BladeCenter-E) in CHASSIS slot: 01 TopoPath is "CHASSIS[1]". Description : BladeCenter-E Width : 1 Sub Type : BladeCenter (BC) Power Mode : 220 v KVM Owner : CHASSIS[1]/BLADE[9] MT Owner : CHASSIS[1]/MGMT_MOD[1] Component Type : CHASSIS Inventory: VPD ID: 336 (decimal) POS ID EXT: 0 (decimal) POS ID: 8 (decimal) Machine Type/Model: 86773RG Machine Serial Number: 99ZL816 Part Number: 39R8561 FRU Number: 39R8563 FRU Serial Number: YK109174W1HV Manufacturer ID: IBM Hardware Revision: 3 (decimal) Manufacture Date: 18 (wk), 07 (yr) UUID: 42E1 5D2F D7BF 41A6 A4A2 48D1 3FB7 0540 (hex) Type Code: 97 (decimal) Sub-type Code: 0 (decimal) IANA Num: 336 (decimal) Product ID: 8 (decimal) Manufacturer Sub ID: FOXC Enviroment data: -------------- Type: : POWER_USAGE Unit: : WATTS Reading: : 0xa Sensor Label: : Midplane Sensor ID: : 0x0 MGMT MOD (Advanced Management Module) in MGMT_MOD slot: 01 TopoPath is "CHASSIS[1]/MGMT_MOD[1]". Description : Advanced Management Module Name : kant Width : 1 Component Role : Primary Component Type : MGMT MOD Insert Time : 28050132 Inventory: VPD ID: 288 (decimal) POS ID EXT: 0 (decimal) POS ID: 4 (decimal) Part Number: 39Y9659 FRU Number: 39Y9661 FRU Serial Number: YK11836CE2RC Manufacturer ID: IBM Hardware Revision: 4 (decimal) Manufacture Date: 50 (wk), 06 (yr) UUID: 1D95 9937 8CA5 11DB 9499 0014 5EDF 1C98 (hex) Type Code: 81 (decimal) Sub-type Code: 1 (decimal) IANA Num: 20301 (decimal) Product ID: 65 (decimal) Manufacturer Sub ID: ASUS Firmware data: Type : AMM firmware Build ID : BPET50P File Name : CNETCMUS.PKT Release Date : 03/26/2010 Release Level : 50 Revision - Major: 80 Port info: ======================================================== Topology Path ID : 1 Label : External Phy Orientation : EXTERNAL Port Number : 1 Type : MGT Physical Meidum : Copper Number of Link Intferfaces : 1 ------------------------------------ Link Ifc ID Number : 1 Link Ifc Transport Protocol : ENET Link Ifc Addr Type : MAC Link Ifc Burned-in Addr : xx:xx:xx:xx:xx:xx Link Ifc Admin Addr : 00:00:00:00:00:00 Link Ifc Addr in use : xx:xx:xx:xx:xx:xx ---------------------------------------------------------- Configuration behaviors: Save Only Enviroment data: -------------- Type: : TEMPERATURE Unit: : DEGREES_C Reading: : 38.00 Sensor Label: : MM Ambient Sensor ID: : 0x0 -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +4.81 Sensor Label: : +5V Sensor ID: : 0x1b -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +3.26 Sensor Label: : +3.3V Sensor ID: : 0x19 -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +11.97 Sensor Label: : +12V Sensor ID: : 0x16 -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : -4.88 Sensor Label: : -5V Sensor ID: : 0x1e -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +2.47 Sensor Label: : +2.5V Sensor ID: : 0x18 -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +1.76 Sensor Label: : +1.8V Sensor ID: : 0x15 -------------- Type: : POWER_USAGE Unit: : WATTS Reading: : 0x19 Sensor Label: : kant Sensor ID: : 0x0

    Read the article

  • Auto populate Outlook with other users' calendars

    - by bduncanj
    In Outlook 2007, when in Calendar view, there's a category (group) of calendars on the left hand bar titled "People's Calendars". We're migrating from a system where all employees have access to read and write to all other employees' calendars (via a 3rd party Web Calendar). Is it possible, from an admin level, to auto-populate this People's Calendars category in everyone's Outlook with all the employees in the company, and grant everyone read / write access to everyone else's calendars? (Running Exchange 2010) Thanks, Duncan

    Read the article

  • Super Noob C++ variable help

    - by julian
    Ok, I must preface this by stating that I know so so little about c++ and am hoping someone can just help me out... I have the below code: string GoogleMapControl::CreatePolyLine(RideItem *ride) { std::vector<RideFilePoint> intervalPoints; ostringstream oss; int cp; int intervalTime = 30; // 30 seconds int zone =ride->zoneRange(); if(zone >= 0) { cp = 300; // default cp to 300 watts } else { cp = ride->zones->getCP(zone); } foreach(RideFilePoint* rfp, ride->ride()->dataPoints()) { intervalPoints.push_back(*rfp); if((intervalPoints.back().secs - intervalPoints.front().secs) > intervalTime) { // find the avg power and color code it and create a polyline... AvgPower avgPower = for_each(intervalPoints.begin(), intervalPoints.end(), AvgPower()); // find the color QColor color = GetColor(cp,avgPower); // create the polyline CreateSubPolyLine(intervalPoints,oss,color); intervalPoints.clear(); intervalPoints.push_back(*rfp); } } return oss.str(); } void GoogleMapControl::CreateSubPolyLine(const std::vector<RideFilePoint> &points, std::ostringstream &oss, QColor color) { oss.precision(6); QString colorstr = color.name(); oss.setf(ios::fixed,ios::floatfield); oss << "var polyline = new GPolyline(["; BOOST_FOREACH(RideFilePoint rfp, points) { if (ceil(rfp.lat) != 180 && ceil(rfp.lon) != 180) { oss << "new GLatLng(" << rfp.lat << "," << rfp.lon << ")," << endl; } } oss << "],\"" << colorstr.toStdString() << "\",4);"; oss << "GEvent.addListener(polyline, 'mouseover', function() {" << endl << "var tooltip_text = 'Avg watts:" << avgPower <<" <br> Avg Speed: <br> Color: "<< colorstr.toStdString() <<"';" << endl << "var ss={'weight':8};" << endl << "this.setStrokeStyle(ss);" << endl << "this.overlay = new MapTooltip(this,tooltip_text);" << endl << "map.addOverlay(this.overlay);" << endl << "});" << endl << "GEvent.addListener(polyline, 'mouseout', function() {" << endl << "map.removeOverlay(this.overlay);" << endl << "var ss={'weight':5};" << endl << "this.setStrokeStyle(ss);" << endl << "});" << endl; oss << "map.addOverlay (polyline);" << endl; } And I'm trying to get the avgPower from this part: AvgPower avgPower = for_each(intervalPoints.begin(), intervalPoints.end(), AvgPower()); the first part to cary over to the second part: << "var tooltip_text = 'Avg watts:" << avgPower <<" <br> Avg Speed: <br> Color: "<< colorstr.toStdString() <<"';" << endl But of course I haven't the slightest clue how to do it... anyone feeling generous today? Thanks in advance

    Read the article

  • Speaking at SQLRelay. Will you be there?

    - by jamiet
    SQL Relay (#sqlrelay) is fast approaching and I wanted to take this opportunity to tell you a little about it.SQL Relay is a 5-day tour around the UK that is taking in five Server Server user groups, each one comprising a full day of SQL Server related learnings. The dates and venues are:21st May, Edinburgh22nd May, Manchester23rd May, Birmingham24th May, Bristol30th May, LondonClick on the appropriate link to see the full agenda and to book your spot.SQL Relay features some of this country's most prominent SQL Server speakers including Chris Webb, Tony Rogerson, Andrew Fryer, Martin Bell, Allan Mitchell, Steve Shaw, Gordon Meyer, Satya Jayanty, Chris Testa O'Neill, Duncan Sutcliffe, Rob Carrol, me and SQL Server UK Product Manager Morris Novello so I really encourage you to go - you have my word it'll be an informative and, more importantly, enjoyable day out from your regular 9-to-5.I am presenting my session "A Lap Around the SSIS Catalog" at Edinburgh and Manchester so if you're going, I hope to see you there.@Jamiet

    Read the article

  • Presenting at SQLBits 9!

    - by andyleonard
    Introduction 2011 is turning into The Year of Pre-Cons! SQLBits 9 , Here I Come! (Love this graphic!) There are some awesome pre-conference sessions lined up for SQLBits 9 Training Day by presenters such as: Allen White, Maciej Pilecki, Matt Masson, Christian Bolton, Satya SK Jayanty, Marco Russo, Duncan Sutcliffe, Jeremy Kashel, and Martijn Evers. Plus me! I know – I can hardly believe it myself! As I type this, I’m working on a gig in Saskatchewan. I had to learn to speak Canadian for the trip...(read more)

    Read the article

  • Functional or non-functional requirement?

    - by killer_PL
    I'm wondering about functional or non-functional requirements. I have found lot of different definitions for those terms and I can't assign some of my requirement to proper category. I'm wondering about requirements that aren't connected with some action or have some additional conditions, for example: On the list of selected devices, device can be repeated. Database must contain at least 100 items Currency of some value must be in USD dollar. Device must have a name and power consumption value in Watts. are those requirements functional or non-functional ?

    Read the article

  • What Exactly Does the Wattage Rating on a Power Supply Unit Mean?

    - by Jason Fitzpatrick
    Your PSU is rated 80 Plus Bronze and for 650 watts, but what exactly does that mean? Read on to see how wattage and power efficiency ratings translate to real world use. Today’s Question & Answer session comes to us courtesy of SuperUser—a subdivision of Stack Exchange, a community-drive grouping of Q&A web sites. How To Use USB Drives With the Nexus 7 and Other Android Devices Why Does 64-Bit Windows Need a Separate “Program Files (x86)” Folder? Why Your Android Phone Isn’t Getting Operating System Updates and What You Can Do About It

    Read the article

  • What is the reason for high power consumption in 12.04?

    - by tom
    I haven't seen this exact question posted or any related answers, so I'm re-posting. Here is the problem: After upgrading to Ubuntu 12.04 Precise Pangolin, my t420s laptop idles above 20 watts (right now with only Chrome running, I'm using 25.4 W) I had a similar problem with Ubuntu 11.10, but after much tweaking the power consumption came down < 10 W on idle. The primary culprit to the 11.10 problem was supposedly fixed by default in 12.04. So my question is, what is happening now? Computer: Lenovo Thinkpad t420s, with Intel i5-2520M @2.5 Ghz - 2x 4gb ram - disk 0 HITACHI 320 Gb - disk 1 SATA SSD 128 Gb

    Read the article

  • Extracting Certain XML Elements with PHP SimpleXML

    - by Peter
    I am having some problems parsing this piece of XML using SimpleXML. There is always only one Series element, and a variable number of Episode elements beneath. I want to parse XML so I can store the Series data in one table, and all the Episode data in another table. XML: <Data> <Series> <id>80348</id> <Genre>|Action and Adventure|Comedy|Drama|</Genre> <IMDB_ID>tt0934814</IMDB_ID> <SeriesID>68724</SeriesID> <SeriesName>Chuck</SeriesName> <banner>graphical/80348-g.jpg</banner> </Series> <Episode> <id>935481</id> <Director>Robert Duncan McNeill</Director> <EpisodeName>Chuck Versus the Third Dimension 2D</EpisodeName> <EpisodeNumber>1</EpisodeNumber> <seasonid>27984</seasonid> <seriesid>80348</seriesid> </Episode> <Episode> <id>935483</id> <Director>Robert Duncan McNeill</Director> <EpisodeName>Buy More #15: Employee Health</EpisodeName> <EpisodeNumber>2</EpisodeNumber> <seasonid>27984</seasonid> <seriesid>80348</seriesid> </Episode> </Data> When I attempt to access just the first Series element and child nodes, or iterate through the Episode elements only it does not work. I have also tried to use DOMDocument with SimpleXML, but could not get that to work at all. PHP Code: <?php if(file_exists('en.xml')) { $data = simplexml_load_file('en.xml'); foreach($data as $series) { echo 'id: <br />' . $series->id; echo 'imdb: <br />' . $series->IMDB_ID; } } ?> Output: id:80348 imdb:tt0934814 id:935481 imdb: id:1534641 imdb: Any help would be greatly appreciated.

    Read the article

< Previous Page | 2 3 4 5 6 7 8  | Next Page >