Search Results

Search found 8320 results on 333 pages for 'console modding'.

Page 60/333 | < Previous Page | 56 57 58 59 60 61 62 63 64 65 66 67  | Next Page >

  • Tuning B2B Server Engine Threads in SOA Suite 11g

    - by Shub Lahiri, A-Team
    Background B2B 11g has a number of parameters that can be tweaked to tune the engine for handling high volumes of messages. These parameters are also known as B2B server properties and managed via the EM console.  This note highlights one aspect of the tuning exercise and describes the different threads, that can be configured to tune the performance of a B2B server. Symptoms The most common indicator of a B2B engine in need of a tuning is reflected in the constant build-up of messages in an internal JMS queue within the B2B server. It is called B2B_EVENT_QUEUE and can be monitored via the Weblogic server console. Whenever such a behaviour is seen, it usually results in general degradation of performance. Remedy There could be many contributing factors behind a B2B server's degradation of performance. However, one of the first places to tune the server from the out-of-the-box, default configuration is to change the number of internal engine threads allocated within the B2B server. Usually the default configuration for the B2B server engine threads is not suitable for high-volume of messaging loads. So, it is necessary to increase the counts for 3 types of such threads, by specifying the appropriate B2B server properties via the EM console, namely, Inbound - b2b.inboundThreadCount Outbound - b2b.outboundThreadCount Default - b2b.defaultThreadCount The function of these threads are fairly self-explanatory. In other words, the inbound threads process the inbound messages that are coming into the B2B server from an external endpoint. Similarly, the outbound threads processes the messages that are sent out from the B2B server. The default threads are responsible for certain B2B server-specific special tasks. In case the inbound and outbound thread counts are not specified, the default thread count also dictates the total number of inbound and outbound threads. As found in any tuning exercise, the optimisation of these threads is usually reached via an iterative process. The best working combination of the thread counts are directly related to the system infrastructure, traffic load and several other environmental factors.

    Read the article

  • cygwin GNU make .net program piping inconsistent behavior

    - by Codism
    This question may sound like a superuser question but I feel there is something related to programming. Anyway, my computer had a fresh installation of Win 7 64 and cygwin recently. Now I observed some problem with pipe handling in gnu make file. The following is the Makefile I use to reproduce the issue: all: fsutil | cat my-dotnet-console.exe | cat The problem is: for the first command line, the piping works every time but for the second command line, the piping barely works - I got no result for the second command for most cases, regardless of the environment (cmd or bash) in which the make file is invoked. However, if I copy paste the second command line into cmd (or bash), the pipe works every time. The following is my .net program: static void Main(string[] args) { Console.WriteLine(new string('a', 40)); Console.Out.Flush(); } The make version is 3.82.90 but the same problem was observed in a previous version (because of the windows path handling problem in 3.82.9, I replaced make.exe with a previous version). I don't know the exact cygwin version I have installed but the current version on cygwin.com is 1.7.11-1. Currently, my work around is to redirect the output to a temporary file but it would be great if I can avoid the temporary file. Thanks

    Read the article

  • How do I connect to my running VM via virsh?

    - by Avery Chan
    My VM has already been started via virsh start chameleon.ootbdev. When I do a virsh console chameleon.ootbdev I get the following output: Connected to domain chameleon.ootbdev Escape character is ^] error: internal error cannot find character device (null) Doing a google search on this led me to this "solution". Unfortunately, editing the domain via virsh edit chameleon.ootbdev doesn't seem to stick. I suspect the issue is that I'm inserting the XML incorrectly: the instructions from the link ask me to insert the following XML into the domain XML file. <serial type='pty'> <target port='0'/> </serial> <console type='pty'> <target type='serial' port='0'/> </console> I've posted my domain XML file to pastebin here. This is AFTER I've tried to insert the above XML. I inserted this XML after the </devices> block. My primary question is: How do I connect to the running VM? A secondary question would be: How do I edit the domain file with the above XML and get the changes to stick?

    Read the article

  • How to implement fast search on Azure Blob?

    - by Vicky
    I am done with writing the code to upload files (text files) to azure blob storage. Now I want to provide search based on text files content. For ex. If I search for "Hello" then the name of files that contains "Hello" words should appear in search result. Here my code to search class BlobSearch { static void Main(string[] args) { string searchText = "Hello"; CloudStorageAccount account = CloudStorageAccount.Parse(azureConString); CloudBlobClient blobClient = account.CreateCloudBlobClient(); CloudBlobContainer blobContainer = blobClient.GetContainerReference("MyBlobContainer"); blobContainer.FetchAttributes(); var blobItemList = blobContainer.ListBlobs(); foreach (var item in blobItemList) { string line = string.Empty; CloudBlockBlob blockBlob = blobContainer.GetBlockBlobReference(item.Uri.ToString()); if(blockBlob.Name.Contains(".txt")) { int lineno = 1; using (var stream = blockBlob.OpenRead()) { using (StreamReader reader = new StreamReader(stream)) { while ((line = reader.ReadLine()) != null) { if (line.IndexOf(searchText) != -1) { Console.WriteLine("Line : " + lineno +" => "+ blockBlob.Name); } lineno++; } } } } } Console.WriteLine("SEARCH COMPLETE"); Console.ReadLine(); } } Above code is working but it is too slow. Is there any way to do it faster or Can improve above code.

    Read the article

  • A Consol Application or Windows Application in VS 2010 for Sharepoint 2010 : A common Error

    - by Gino Abraham
    I have seen many Sharepoint Newbies cracking their head to create a Console/Windows  application in VS2010 and make it talk to Sharepoint 2010 Server. I had the same problem when i started with Sharepoint in the begining. It is important for you to acknowledge that SharePoint 2010 is based on .NET Framework version 3.5 and not version 4.0. In VS 2010 when you create a Console/Windows application, Make Sure you select .Net Framework 3.5 in the New Project Dialog Window.If you have missed while creating new Project Go to the Application tab of project properties and verify that .NET Framework Version 3.5 is select as the Target Framework. Now that you have selected the correct framework, will it work? Nope if the application is configured as x86 one it will not work. Sharepoint is a 64 Bit application and when you create a windows application to talk to Sharepoint it should also be a 64 Bit one. Go to Configuration Manager, Select x64. If x64 is not available select <New…> and in the New Solution Platform dialog box select x64 as the new platform copying settings from x86 and checking the Create new project platforms check box. This is not applicable if you are making a console application to talk to sharepoint with Client Object Model.

    Read the article

  • What does Skyrim Creation Kit's NPC class do?

    - by pseudoname
    I'm trying to change it with the setclass console command Based on the UESP wiki it looks like it just governs stat gain for leveling, but based on the Elder Scrolls wiki it seems to only control their combat AI. Obviously it does at least one or both of those - what does it actually do, and does it do anything else? __ Ex: if change Lydia from warrior1handed to vigilantcombat1h with the console command 000A2C94.setclass 0010bfef will it have any unintended side effects that aren't immediately apparent other than letting her use the alteration and healing spells I just gave her with console and setting her stats in a way that works for that? Will it do something weird like mess with her factions or ability to join as my follower? Or mess with her health scaling as she levels? Something hard to notice until alot of time went by? @desaivv* I was trying to do it with 000A2C94.setclass 0010bfef wasn't sure if it'd cause hidden issues only showing after hours of play or if i made a new character with the same bat file. but the creation kit sounds like an idea too, i'll have to see how complicated it is. it might just show what it'd do or have some easier way to change her behavior to add spells. I'll try it and see if anything obvious shows up short term just wasn't sure if it had known long term problems

    Read the article

  • Monitoring settings in a configsection of your app.config for changes

    - by dotjosh
    The usage:public static void Main() { using(var configSectionAdapter = new ConfigurationSectionAdapter<ACISSInstanceConfigSection>("MyConfigSectionName")) { configSectionAdapter.ConfigSectionChanged += () => { Console.WriteLine("File has changed! New setting is " + configSectionAdapter.ConfigSection.MyConfigSetting); }; Console.WriteLine("The initial setting is " + configSectionAdapter.ConfigSection.MyConfigSetting); Console.ReadLine(); } }  The meat: public class ConfigurationSectionAdapter<T> : IDisposable where T : ConfigurationSection { private readonly string _configSectionName; private FileSystemWatcher _fileWatcher; public ConfigurationSectionAdapter(string configSectionName) { _configSectionName = configSectionName; StartFileWatcher(); } private void StartFileWatcher() { var configurationFileDirectory = new FileInfo(Configuration.FilePath).Directory; _fileWatcher = new FileSystemWatcher(configurationFileDirectory.FullName); _fileWatcher.Changed += FileWatcherOnChanged; _fileWatcher.EnableRaisingEvents = true; } private void FileWatcherOnChanged(object sender, FileSystemEventArgs args) { var changedFileIsConfigurationFile = string.Equals(args.FullPath, Configuration.FilePath, StringComparison.OrdinalIgnoreCase); if (!changedFileIsConfigurationFile) return; ClearCache(); OnConfigSectionChanged(); } private void ClearCache() { ConfigurationManager.RefreshSection(_configSectionName); } public T ConfigSection { get { return (T)Configuration.GetSection(_configSectionName); } } private System.Configuration.Configuration Configuration { get { return ConfigurationManager.OpenExeConfiguration(ConfigurationUserLevel.None); } } public delegate void ConfigChangedHandler(); public event ConfigChangedHandler ConfigSectionChanged; protected void OnConfigSectionChanged() { if (ConfigSectionChanged != null) ConfigSectionChanged(); } public void Dispose() { _fileWatcher.Changed -= FileWatcherOnChanged; _fileWatcher.EnableRaisingEvents = false; _fileWatcher.Dispose(); } }

    Read the article

  • Will BIOS boot mode Ubuntu install be able to boot when firmware "Fast Boot" is "Ultra Fast"?

    - by Pro Backup
    I have an AsRock mainboard with UEFI BIOS P1.50 02/14/2014. The firmware "Fast Boot" option is set to "Fast", Boot Option #1 is set to "AHCI P4: OCZ-VERT...": this is BIOS not UEFI boot. This boot disk has an MBR partitioning scheme (# parted -l | grep Partition\ Table:). Therefore Ubuntu 14.04 is installed in BIOS/CMS (Grub-PC) mode. The Ubuntu boot process ends in a text console (no GUI). There is no external graphics card in use. The stock Ubuntu kernel is replaced with Ubuntu supplied mainline 3.16.0-031600rc6-generic. dmesg outputs lines containing BIOS, like: SMBIOS 2.7 present Calgary: detecting Calgary via BIOS EBDA area Calgary: Unable to locate Rio Grande table in EBDA - bailing! [Firmware Bug]: ACPI: BIOS _OSI(Linux) query ignored BIOS EDD facility v0.16 2004-Jun-25, 0 devices found The ASRock BIOS it selves display this help text for "Ultra Fast - Fast Boot": Ultra Fast mode is only supported by Windows 8 and the VBIOS must support UEFI GOP if you are using an external graphics card. Please notice that Ultra Fast mode will boot so fast that the only way to enter this UEFI Setup Utility is to Clear CMOS or run the Restart to UEFI utility in Windows. Assumptions: I suspect after changing UEFI setting "Fast Boot" to "Ultra Fast" that the machine will no longer boot into Ubuntu's console. I expect when first exchanging "Grub-pc" with "Grub-efi", that the machine will still be able to boot to a grub menu (thus allowing to change the "Fast Boot" setting back to "Fast" without clearing CMOS). Are these two "Fast Boot" assumptions correct, and/or, may I expect Ubuntu 14.04 running mainline kernel 3.16rc6 and Grub-efi to still boot to console after enabling UEFI Ultra Fast Boot?

    Read the article

  • New "delay" keyword for JavaScript

    - by Van Coding
    I had a great idea for a new javascript keyword "delay", but I don't know what I can do to bring it to the new specification. Also I want to know what you guys think about it and if it's even realistic. What does the delay keyword ? The delay keyword does nothing more than stop the execution of the current stack and immediately continues to the next "job" in the queue. But that's not all! Instead of discarding the stack, it adds it to the end of the queue. After all "jobs" before it are done, the stack continues to execute. What is it good for? delay could help make blocking code non-blocking while it still looks like synchronous code. A short example: setTimeout(function(){ console.log("two"); },0); console.log("one"); delay; //since there is currently another task in the queue, do this task first before continuing console.log("three"); //Outputs: one, two, three This simple keyword would allow us to create a synchronous-looking code wich is asynchronous behind the scenes. Using node.js modules, for example, would no longer be impossible to use in the browser without trickery. There would be so many possibilites with such a keyword! Is this pattern useful? What can I do to bring this into the new ECMAscript specification? Note: I asked this previously on Stack Overflow, where it was closed.

    Read the article

  • How can I programmatically change the keyboard layout?

    - by Jason R. Coombs
    I want to run a shell command or script that will configure each of my Ubuntu Precise boxes to use the Dvorak keyboard layout as the default (and only) layout. With earlier versions, I was able to set the XKBVARIANT in /etc/default/keyboard but when I make this change in Precise (and reboot), the keyboard layout appears to be unaffected (both in console and in gnome). I tried also setting the XKBMODEL to pc105 and XKBLAYOUT to us, but that did not seem to help. I know I can set the layout for gnome using the 'keyboard layout' tool... but I want the change to affect the console, and I want to automate the process. How can I accomplish this? Edit: To clarify, I want to know how I can cause to change (using only a script or command-line) the keyboard layout to be Dvorak as the default and only keyboard layout for both Gnome and the console. I want this change to be persistent (survive reboots), just as it is when the change is made through the Keyboard Layout tool. Edit: Let me put it another way. If I had installed the operating system myself (which I did not because the OS was installed by the virtual machine infrastructure), I could have selected the desired keyboard layout at install time, and that layout would be applied persistently, system-wide. How can I change the layout to appear as if I had set it during the install process?

    Read the article

  • BizTalk 2009 - How do I do t"HAT"?

    - by StuartBrierley
    In my previous life working with BizTalk Server 2004, I came to view HAT (the Health and Activity Tracking tool) as one of my first ports of call in the case of problems with any of our BizTalk solutions.  When you move to BizTalk Server 2009 it is quickly apparent that HAT is no longer with us. HAT was useful in BizTalk 2004 mainly as it provided developers and administrators with a number of useful queries and views of what was going on inside BizTalk at runtime; when and what type of messages were received and sent, what messages had been suspended, what orchestration were running or suspended, you could even follow the process flow of a message or orchestration to see what was going on. With BizTalk Server 2009 much of the functionality of HAT can now be found in the BizTalk Administration console.  Select a BizTalk Group and you will be shown the Group Hub Overview page.  This provides a number of default queries that replicate some of those found in the old HAT. You can also use the Group Hub page to create new queries.  These can then be saved and loaded in other Group Hub instances - useful for creating queries in development for later use in Test, Psuedo-Live and Live environments. In the next few posts I am going to look at some of the common queries that we might miss from HAT and recreate them (or something close) using the new query option. Messages - last 100 received Messages - last 100 sent Messages - last 50 suspended Service instances - last 100 I have yet to try the updated Admin-HAT-Console in anger, and after using old-HAT for so long it may take some getting uesd to, but so far I would say that moving the HAT functionality into the BizTalk Administration console was probably the correct way to go.  Having one tool as the place to look for the combined functionality on offer certainly seems to be the sensible option.

    Read the article

  • Ubuntu Server 11.10 boot, white terminal with garbled black text

    - by SpeedCrazy
    I just installed Ubuntu server 11.10 and the install went fine. This system is running on an Intel Pentium II board with onboard graphics. However when I try to boot into Ubuntu I get a white terminal with garbled black text. I have tried various grub 'fixes' as googling the issue seemed to suggest it was a res or grub related issue. I cannot ssh in so the issue does affect Linux as well. I have had no luck with anything thus far and am at my wits end. This was my first Ubuntu excursion as my friend told me it was better for servers than CentOS because it was easier... Not so much.... Does anyone have any ideas as to what the issue could be? When answering bear in mind I am an Ubuntu noob and Linux novice. As of 1/26/12 I have tried to add the console=ttyl line to the /etc/default/grub and run update-grub. This results in the line in the boot parameters that normally reads: linux /vmlunz-3.0.0-12-generic-pae root=/dev/mapper/dev-root rovt.handoff=7 now reads: linux /vmlunz-3.0.0-12-generic-pae root=/dev/mapper/dev-root ro console=ttyl vt.handoff=7 This does not work. Is there anyway to have console=ttyl inserted on a line by itself? I am at my wits ends, Thanks for all your help, Speed

    Read the article

  • How do I remove the tool tips on the launch bar?

    - by Sephethus
    The title is the question. These tool tips stay until I try to click past them. They're annoying since they constantly pop up and block the view of what I'm trying to do. Unfortunately I need the launch bar because Ubuntu is running on VMware and the console does not allow me to use the keyboard for switching tasks (to my knowledge). How do I disable them? I'd post an image as an example, but this site will not let me. UPDATE: unity 5.16.0 UPDATE 2: I discovered that this may only be a problem with users who run Ubuntu on a full screen VMware console that is situated on the right monitor. When the mouse is moved to the left monitor the tooltips popup and remain until the mouse is clicked twice in the VMware console window to make it active. Unfortunately my problem is one involving a rare situation I think. However, I'd love to be able to disable these tool tips if possible. It would also be nice if new features were added that can allow further customization of the launch bar.

    Read the article

  • hd0 out of disk error results to low graphics mode

    - by msPeachy
    Yesterday, I have reinstalled Ubuntu due to a error: hd0 out of disk on boot. Everything went fine, I've installed apps, perform updates and upgraded the kernel. I've even restarted it a few times just to check if I would encounter boot issues and was glad that everything was working perfectly, then powered it down. The next morning when I boot, I got this error: hd0 out of disk error. Press any key to continue... again! After pressing a key, it took 10 minutes for the Ubuntu logo to appear with it's 5 dots. After another 5 minutes, Ubuntu started checking the disk and displayed a message that / has errors, I pressed F to fix the errors. After which Ubuntu tells me that /tmp is not yet ready for mounting so I pressed S to skip mounting it, then Ubuntu restarted. On boot I saw the error: hd0 out of disk error. Press any key to continue... again. This time it took only a minute for the Ubuntu logo to appear and after another minute a dialog box appeared with the following message: The system is running in low-graphics mode. Your screen, graphics card, and input settings could not be detected correctly. You will have to configure these yourself. What would you like to do? Run in low-graphics mode for just one session Reconfigure graphics Troubleshoot the error Exit to console login Whichever option I choose I ended up with a console prompt: grub-editenv: error: cannot read the file /boot/grub/grubenv. _ I can't do anything on this console, whatever I type nothing happens. I've rebooted several times and I get same error every time. I don't quite understand what is wrong with Ubuntu or with my installation. I've encountered this hd0 out of disk error several times already and always ended up reinstalling. I'd really really appreciate it if you guys can help me fix this. Thank you and good day.

    Read the article

  • Resource Acquisition is Initialization in C#

    - by codeWithoutFear
    Resource Acquisition Is Initialization (RAII) is a pattern I grew to love when working in C++.  It is perfectly suited for resource management such as matching all those pesky new's and delete's.  One of my goals was to limit the explicit deallocation statements I had to write.  Often these statements became victims of run-time control flow changes (i.e. exceptions, unhappy path) or development-time code refactoring. The beauty of RAII is realized by tying your resource creation (acquisition) to the construction (initialization) of a class instance.  Then bind the resource deallocation to the destruction of that instance.  That is well and good in a language with strong destructor semantics like C++, but languages like C# that run on garbage-collecting runtimes don't provide the same instance lifetime guarantees. Here is a class and sample that combines a few features of C# to provide an RAII-like solution: using System; namespace RAII { public class DisposableDelegate : IDisposable { private Action dispose; public DisposableDelegate(Action dispose) { if (dispose == null) { throw new ArgumentNullException("dispose"); } this.dispose = dispose; } public void Dispose() { if (this.dispose != null) { Action d = this.dispose; this.dispose = null; d(); } } } class Program { static void Main(string[] args) { Console.Out.WriteLine("Some resource allocated here."); using (new DisposableDelegate(() => Console.Out.WriteLine("Resource deallocated here."))) { Console.Out.WriteLine("Resource used here."); throw new InvalidOperationException("Test for resource leaks."); } } } } The output of this program is: Some resource allocated here. Resource used here. Unhandled Exception: System.InvalidOperationException: Test for resource leaks. at RAII.Program.Main(String[] args) in c:\Dev\RAII\RAII\Program.cs:line 40 Resource deallocated here. Code without fear! --Don

    Read the article

  • Using ImpactJS: How to set a publicly available variable

    - by Dave Voyles
    I'm trying to get an entity (a bullet, a grenade, and an explosive) from my player player. Specifically, I want the shootingRate of my bullet (how frequently it can be fired). How can I do this without having to call getEntityByType each time I fire this projectile? There has got to be a cleaner way from what I'm doing right now.... // Shooting var isShooting = ig.input.state('shoot'); if (isShooting && this.lastShootTimer.delta() > 0) { switch (this.activeWeapon) { case("EntityBullet"): ig.game.spawnEntity(this.activeWeapon, this.pos.x, this.pos.y - 10); var equipedWeap = ig.game.getEntitiesByType(EntityBullet); this.lastShootTimer.set(equippedWeap.shootingRate); console.log(equipedWeap.shootingRate); break; case("EntityGrenade"): ig.game.spawnEntity(this.activeWeapon, this.pos.x, this.pos.y +5); var equipedWeap = ig.game.getEntitiesByType(EntityGrenade); this.lastShootTimer.set(equipedWeap.shootingRate); console.log(EquipedWeap.shootingRate); break; case("EntityExplosiveBomb"): ig.game.spawnEntity(this.activeWeapon, this.pos.x, this.pos.y +5 ); var equipedWeap = ig.game.getEntitiesByType(EntityExplosiveBomb)[0]; this.lastShootTimer.set(equipedWeap.shootingRate); console.log(equipedWeap.shootingRate); break; } }

    Read the article

  • How to deal with elimination of duplicate logic vs. cost of complexity increase?

    - by Gabriel
    I just wrote some code that is very representative of a recurring theme (in my coding world lately): repeated logic leads to an instinct to eliminate duplication which results in something that is more complex the tradeoff seems wrong to me (the examples of the negative side aren't worth posting - but this is probably the 20th console utility I've written in the past 12 months). I'm curious if I'm missing some techniques or if this is really just on of those "experience tells you when to do what" type of issues. Here's the code... I'm tempted to leave it as is, even though there will be about 20 of those if-blocks when I'm done. static void Main(string[] sargs) { try { var urls = new DirectTrackRestUrls(); var restCall = new DirectTrackRestCall(); var logger = new ConsoleLogger(); Args args = (Args)Enum.Parse(typeof(Args), string.Join(",", sargs)); if (args.HasFlag(Args.Campaigns)) { var getter = new ResourceGetter(logger, urls.ListAdvertisers, restCall); restCall.UriVariables.Add("access_id", 1); getter.GotResource += new ResourceGetter.GotResourceEventHandler(getter_GotResource); getter.GetResources(); SaveResources(); } if (args.HasFlag(Args.Advertisers)) { var getter = new ResourceGetter(logger, urls.ListAdvertisers, restCall); restCall.UriVariables.Add("access_id", 1); getter.GotResource += new ResourceGetter.GotResourceEventHandler(getter_GotResource); getter.GetResources(); SaveResources(); } if (args.HasFlag(Args.CampaignGroups)) { var getter = new ResourceGetter(logger, urls.ListCampaignGroups, restCall); getter.GotResource += new ResourceGetter.GotResourceEventHandler(getter_GotResource); getter.GetResources(); SaveResources(); } } catch (Exception e) { Console.WriteLine(e.InnerException); Console.WriteLine(e.StackTrace); }

    Read the article

  • How to revert to Eclipse's old behavior when double-clicking on frames or windows, in Juno?

    - by mattquiros
    I find Eclipse Juno very counter-intuitive. In my workspace, I used to just have the package view at the left, my code on the right, and whenever I'm printing something in the console, that's only when the console frame shows up from the bottom right. When you double click on a particular window, it either only goes fullscreen within Eclipse, or back to its original size together with the size of the other frames. In Juno, however, it seems that frames are put on layers on top of each other. When I print something to the console, the output frame only shows up as a small, useless square to my right. When I double-click, it goes full screen. When I double-click again, it occupies the full right frame, hiding my code. I double-click again and it goes full screen, then it double-clicks before it shares the right frame with my code on top of it. Then when I minimize it, it goes to the side. Any way to go back to the good old days of Eclipse? Thanks.

    Read the article

  • Simple Introduction to using the Enterprise Manager SOA/BPM Facade API by Jaideep Ganguli

    - by JuergenKress
    There may be times when you need to expose just a small section of what is displayed in the Enterprise Manager console for SOA/BPM (EM console). A simple example can be where stakeholders on the systems integration or customer teams want to monitor a dashboard of statistics on how many instances of a composite have been created and how many have faulted. You can see this in the EM, as shown below Some of these stakeholders may not have knowledge of  EM console and they just want a quick view into the statistics, without having to navigate EM. This post describes how to use the Oracle Fusion Middleware Infrastructure Management Java API  for Oracle SOA Suite (also called the Facade API)  to build a custom ADF page to display this information. If you want a quick introduction in using the Facade API, this post is for you. Read the complete article here. SOA & BPM Partner Community For regular information on Oracle SOA Suite become a member in the SOA & BPM Partner Community for registration please visit www.oracle.com/goto/emea/soa (OPN account required) If you need support with your account please contact the Oracle Partner Business Center. Blog Twitter LinkedIn Facebook Wiki Technorati Tags: Enterprise Manager,SOA Community,Oracle SOA,Oracle BPM,Community,OPN,Jürgen Kress

    Read the article

  • Nodejs removing event listeners [migrated]

    - by JeffH
    Looking to get some help. I'm new to Nodejs and wondering if it is possible, to remove this custom event emitter. Most of this code comes from the Hand on nodejs by Pedro Teixeira. My function at the bottom is attempting to remove the custom event emitter you setup in the book. var util = require('util'); var EventEmitter = require('events').EventEmitter; // Pseudo-class named ticker that will self emit every 1 second. var Ticker = function() { var self = this; setInterval(function() { self.emit('tick'); }, 1000); }; // Bind the new EventEmitter to the sudo class. util.inherits(Ticker, EventEmitter); // call and instance of the ticker class to get the first // event started. Then let the event emitter run the infinante loop. var ticker = new Ticker(); ticker.on('tick', function() { console.log('Tick'); }); (function tock() { setInterval(function() { console.log('Tock'); EventEmitter.removeListener('Ticker',function() { console.log("Clocks Dead!"); }); }, 5000); })();

    Read the article

  • Issue updating domain name servers from BlueHost to AWS

    - by cowls
    I am trying to migrate my site hosting from bluehost to AWS cloud based service. I have the site up and running on AWS with an elastic IP configured, it loads fine when I specify the IP address in the browser. I have gone into Route 53 on the AWS console and created a "hosted zone" for the domain. I then created a new record set of type "A" using the IP address as the value. I have a domain name registered with bluehost. Ive logged into the bluehost account and updated the domain name servers to point to those specified in Route 53 in the AWS console. When I hit the IP address directly the site loads, however it doesn't load when using the domain name (I get a google chrome oops error page saying page is not found) I've tried using this site: http://dns.squish.net/ to debug but it seems to be giving me the correct results. fizaclegems.com 300 IN A 107.20.209.78 Where 107.20.209.78 matches the elastic IP configured in the AWS console. This is the result it gives for all 4 name servers. Am I missing a step here? Does anyone know what else I should be doing or looking for?

    Read the article

  • JMS Step 4 - How to Create an 11g BPEL Process Which Writes a Message Based on an XML Schema to a JMS Queue

    - by John-Brown.Evans
    JMS Step 4 - How to Create an 11g BPEL Process Which Writes a Message Based on an XML Schema to a JMS Queue ol{margin:0;padding:0} .c11_4{vertical-align:top;width:129.8pt;border-style:solid;background-color:#f3f3f3;border-color:#000000;border-width:1pt;padding:5pt 5pt 5pt 5pt} .c9_4{vertical-align:top;width:207pt;border-style:solid;background-color:#f3f3f3;border-color:#000000;border-width:1pt;padding:5pt 5pt 5pt 5pt}.c14{vertical-align:top;width:207pt;border-style:solid;border-color:#000000;border-width:1pt;padding:5pt 5pt 5pt 5pt} .c17_4{vertical-align:top;width:129.8pt;border-style:solid;border-color:#000000;border-width:1pt;padding:5pt 5pt 5pt 5pt} .c7_4{vertical-align:top;width:130pt;border-style:solid;border-color:#000000;border-width:1pt;padding:0pt 5pt 0pt 5pt} .c19_4{vertical-align:top;width:468pt;border-style:solid;border-color:#000000;border-width:1pt;padding:5pt 5pt 5pt 5pt} .c22_4{background-color:#ffffff} .c20_4{list-style-type:disc;margin:0;padding:0} .c6_4{font-size:8pt;font-family:"Courier New"} .c24_4{color:inherit;text-decoration:inherit} .c23_4{color:#1155cc;text-decoration:underline} .c0_4{height:11pt;direction:ltr} .c10_4{font-size:10pt;font-family:"Courier New"} .c3_4{padding-left:0pt;margin-left:36pt} .c18_4{font-size:8pt} .c8_4{text-align:center} .c12_4{background-color:#ffff00} .c2_4{font-weight:bold} .c21_4{background-color:#00ff00} .c4_4{line-height:1.0} .c1_4{direction:ltr} .c15_4{background-color:#f3f3f3} .c13_4{font-family:"Courier New"} .c5_4{font-style:italic} .c16_4{border-collapse:collapse} .title{padding-top:24pt;line-height:1.15;text-align:left;color:#000000;font-size:36pt;font-family:"Arial";font-weight:bold;padding-bottom:6pt} .subtitle{padding-top:18pt;line-height:1.15;text-align:left;color:#666666;font-style:italic;font-size:24pt;font-family:"Georgia";padding-bottom:4pt} li{color:#000000;font-size:10pt;font-family:"Arial"} p{color:#000000;font-size:10pt;margin:0;font-family:"Arial"} h1{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:18pt;font-family:"Arial";font-weight:normal;padding-bottom:0pt} h2{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:18pt;font-family:"Arial";font-weight:bold;padding-bottom:0pt} h3{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:14pt;font-family:"Arial";font-weight:normal;padding-bottom:0pt} h4{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-style:italic;font-size:11pt;font-family:"Arial";padding-bottom:0pt} h5{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-size:10pt;font-family:"Arial";font-weight:normal;padding-bottom:0pt} h6{padding-top:0pt;line-height:1.15;text-align:left;color:#888;font-style:italic;font-size:10pt;font-family:"Arial";padding-bottom:0pt} This post continues the series of JMS articles which demonstrate how to use JMS queues in a SOA context. The previous posts were: JMS Step 1 - How to Create a Simple JMS Queue in Weblogic Server 11g JMS Step 2 - Using the QueueSend.java Sample Program to Send a Message to a JMS Queue JMS Step 3 - Using the QueueReceive.java Sample Program to Read a Message from a JMS Queue In this example we will create a BPEL process which will write (enqueue) a message to a JMS queue using a JMS adapter. The JMS adapter will enqueue the full XML payload to the queue. This sample will use the following WebLogic Server objects. The first two, the Connection Factory and JMS Queue, were created as part of the first blog post in this series, JMS Step 1 - How to Create a Simple JMS Queue in Weblogic Server 11g. If you haven't created those objects yet, please see that post for details on how to do so. The Connection Pool will be created as part of this example. Object Name Type JNDI Name TestConnectionFactory Connection Factory jms/TestConnectionFactory TestJMSQueue JMS Queue jms/TestJMSQueue eis/wls/TestQueue Connection Pool eis/wls/TestQueue 1. Verify Connection Factory and JMS Queue As mentioned above, this example uses a WLS Connection Factory called TestConnectionFactory and a JMS queue TestJMSQueue. As these are prerequisites for this example, let us verify they exist. Log in to the WebLogic Server Administration Console. Select Services > JMS Modules > TestJMSModule You should see the following objects: If not, or if the TestJMSModule is missing, please see the abovementioned article and create these objects before continuing. 2. Create a JMS Adapter Connection Pool in WebLogic Server The BPEL process we are about to create uses a JMS adapter to write to the JMS queue. The JMS adapter is deployed to the WebLogic server and needs to be configured to include a connection pool which references the connection factory associated with the JMS queue. In the WebLogic Server Console Go to Deployments > Next and select (click on) the JmsAdapter Select Configuration > Outbound Connection Pools and expand oracle.tip.adapter.jms.IJmsConnectionFactory. This will display the list of connections configured for this adapter. For example, eis/aqjms/Queue, eis/aqjms/Topic etc. These JNDI names are actually quite confusing. We are expecting to configure a connection pool here, but the names refer to queues and topics. One would expect these to be called *ConnectionPool or *_CF or similar, but to conform to this nomenclature, we will call our entry eis/wls/TestQueue . This JNDI name is also the name we will use later, when creating a BPEL process to access this JMS queue! Select New, check the oracle.tip.adapter.jms.IJmsConnectionFactory check box and Next. Enter JNDI Name: eis/wls/TestQueue for the connection instance, then press Finish. Expand oracle.tip.adapter.jms.IJmsConnectionFactory again and select (click on) eis/wls/TestQueue The ConnectionFactoryLocation must point to the JNDI name of the connection factory associated with the JMS queue you will be writing to. In our example, this is the connection factory called TestConnectionFactory, with the JNDI name jms/TestConnectionFactory.( As a reminder, this connection factory is contained in the JMS Module called TestJMSModule, under Services > Messaging > JMS Modules > TestJMSModule which we verified at the beginning of this document. )Enter jms/TestConnectionFactory  into the Property Value field for Connection Factory Location. After entering it, you must press Return/Enter then Save for the value to be accepted. If your WebLogic server is running in Development mode, you should see the message that the changes have been activated and the deployment plan successfully updated. If not, then you will manually need to activate the changes in the WebLogic server console. Although the changes have been activated, the JmsAdapter needs to be redeployed in order for the changes to become effective. This should be confirmed by the message Remember to update your deployment to reflect the new plan when you are finished with your changes as can be seen in the following screen shot: The next step is to redeploy the JmsAdapter.Navigate back to the Deployments screen, either by selecting it in the left-hand navigation tree or by selecting the “Summary of Deployments” link in the breadcrumbs list at the top of the screen. Then select the checkbox next to JmsAdapter and press the Update button On the Update Application Assistant page, select “Redeploy this application using the following deployment files” and press Finish. After a few seconds you should get the message that the selected deployments were updated. The JMS adapter configuration is complete and it can now be used to access the JMS queue. To summarize: we have created a JMS adapter connection pool connector with the JNDI name jms/TestConnectionFactory. This is the JNDI name to be accessed by a process such as a BPEL process, when using the JMS adapter to access the previously created JMS queue with the JNDI name jms/TestJMSQueue. In the following step, we will set up a BPEL process to use this JMS adapter to write to the JMS queue. 3. Create a BPEL Composite with a JMS Adapter Partner Link This step requires that you have a valid Application Server Connection defined in JDeveloper, pointing to the application server on which you created the JMS Queue and Connection Factory. You can create this connection in JDeveloper under the Application Server Navigator. Give it any name and be sure to test the connection before completing it. This sample will use the connection name jbevans-lx-PS5, as that is the name of the connection pointing to my SOA PS5 installation. When using a JMS adapter from within a BPEL process, there are various configuration options, such as the operation type (consume message, produce message etc.), delivery mode and message type. One of these options is the choice of the format of the JMS message payload. This can be structured around an existing XSD, in which case the full XML element and tags are passed, or it can be opaque, meaning that the payload is sent as-is to the JMS adapter. In the case of an XSD-based message, the payload can simply be copied to the input variable of the JMS adapter. In the case of an opaque message, the JMS adapter’s input variable is of type base64binary. So the payload needs to be converted to base64 binary first. I will go into this in more detail in a later blog entry. This sample will pass a simple message to the adapter, based on the following simple XSD file, which consists of a single string element: stringPayload.xsd <?xml version="1.0" encoding="windows-1252" ?> <xsd:schema xmlns:xsd="http://www.w3.org/2001/XMLSchema" xmlns="http://www.example.org" targetNamespace="http://www.example.org" elementFormDefault="qualified" <xsd:element name="exampleElement" type="xsd:string"> </xsd:element> </xsd:schema> The following steps are all executed in JDeveloper. The SOA project will be created inside a JDeveloper Application. If you do not already have an application to contain the project, you can create a new one via File > New > General > Generic Application. Give the application any name, for example JMSTests and, when prompted for a project name and type, call the project JmsAdapterWriteWithXsd and select SOA as the project technology type. If you already have an application, continue below. Create a SOA Project Create a new project and choose SOA Tier > SOA Project as its type. Name it JmsAdapterWriteSchema. When prompted for the composite type, choose Composite With BPEL Process. When prompted for the BPEL Process, name it JmsAdapterWriteSchema too and choose Synchronous BPEL Process as the template. This will create a composite with a BPEL process and an exposed SOAP service. Double-click the BPEL process to open and begin editing it. You should see a simple BPEL process with a Receive and Reply activity. As we created a default process without an XML schema, the input and output variables are simple strings. Create an XSD File An XSD file is required later to define the message format to be passed to the JMS adapter. In this step, we create a simple XSD file, containing a string variable and add it to the project. First select the xsd item in the left-hand navigation tree to ensure that the XSD file is created under that item. Select File > New > General > XML and choose XML Schema. Call it stringPayload.xsd and when the editor opens, select the Source view. then replace the contents with the contents of the stringPayload.xsd example above and save the file. You should see it under the xsd item in the navigation tree. Create a JMS Adapter Partner Link We will create the JMS adapter as a service at the composite level. If it is not already open, double-click the composite.xml file in the navigator to open it. From the Component Palette, drag a JMS adapter over onto the right-hand swim lane, under External References. This will start the JMS Adapter Configuration Wizard. Use the following entries: Service Name: JmsAdapterWrite Oracle Enterprise Messaging Service (OEMS): Oracle Weblogic JMS AppServer Connection: Use an existing application server connection pointing to the WebLogic server on which the above JMS queue and connection factory were created. You can use the “+” button to create a connection directly from the wizard, if you do not already have one. This example uses a connection called jbevans-lx-PS5. Adapter Interface > Interface: Define from operation and schema (specified later) Operation Type: Produce Message Operation Name: Produce_message Destination Name: Press the Browse button, select Destination Type: Queues, then press Search. Wait for the list to populate, then select the entry for TestJMSQueue , which is the queue created earlier. JNDI Name: The JNDI name to use for the JMS connection. This is probably the most important step in this exercise and the most common source of error. This is the JNDI name of the JMS adapter’s connection pool created in the WebLogic Server and which points to the connection factory. JDeveloper does not verify the value entered here. If you enter a wrong value, the JMS adapter won’t find the queue and you will get an error message at runtime, which is very difficult to trace. In our example, this is the value eis/wls/TestQueue . (See the earlier step on how to create a JMS Adapter Connection Pool in WebLogic Server for details.) MessagesURL: We will use the XSD file we created earlier, stringPayload.xsd to define the message format for the JMS adapter. Press the magnifying glass icon to search for schema files. Expand Project Schema Files > stringPayload.xsd and select exampleElement: string. Press Next and Finish, which will complete the JMS Adapter configuration. Wire the BPEL Component to the JMS Adapter In this step, we link the BPEL process/component to the JMS adapter. From the composite.xml editor, drag the right-arrow icon from the BPEL process to the JMS adapter’s in-arrow. This completes the steps at the composite level. 4. Complete the BPEL Process Design Invoke the JMS Adapter Open the BPEL component by double-clicking it in the design view of the composite.xml, or open it from the project navigator by selecting the JmsAdapterWriteSchema.bpel file. This will display the BPEL process in the design view. You should see the JmsAdapterWrite partner link under one of the two swim lanes. We want it in the right-hand swim lane. If JDeveloper displays it in the left-hand lane, right-click it and choose Display > Move To Opposite Swim Lane. An Invoke activity is required in order to invoke the JMS adapter. Drag an Invoke activity between the Receive and Reply activities. Drag the right-hand arrow from the Invoke activity to the JMS adapter partner link. This will open the Invoke editor. The correct default values are entered automatically and are fine for our purposes. We only need to define the input variable to use for the JMS adapter. By pressing the green “+” symbol, a variable of the correct type can be auto-generated, for example with the name Invoke1_Produce_Message_InputVariable. Press OK after creating the variable. ( For some reason, while I was testing this, the JMS Adapter moved back to the left-hand swim lane again after this step. There is no harm in leaving it there, but I find it easier to follow if it is in the right-hand lane, because I kind-of think of the message coming in on the left and being routed through the right. But you can follow your personal preference here.) Assign Variables Drag an Assign activity between the Receive and Invoke activities. We will simply copy the input variable to the JMS adapter and, for completion, so the process has an output to print, again to the process’s output variable. Double-click the Assign activity and create two Copy rules: for the first, drag Variables > inputVariable > payload > client:process > client:input_string to Invoke1_Produce_Message_InputVariable > body > ns2:exampleElement for the second, drag the same input variable to outputVariable > payload > client:processResponse > client:result This will create two copy rules, similar to the following: Press OK. This completes the BPEL and Composite design. 5. Compile and Deploy the Composite We won’t go into too much detail on how to compile and deploy. In JDeveloper, compile the process by pressing the Make or Rebuild icons or by right-clicking the project name in the navigator and selecting Make... or Rebuild... If the compilation is successful, deploy it to the SOA server connection defined earlier. (Right-click the project name in the navigator, select Deploy to Application Server, choose the application server connection, choose the partition on the server (usually default) and press Finish. You should see the message ---- Deployment finished. ---- in the Deployment frame, if the deployment was successful. 6. Test the Composite This is the exciting part. Open two tabs in your browser and log in to the WebLogic Administration Console in one tab and the Enterprise Manager 11g Fusion Middleware Control (EM) for your SOA installation in the other. We will use the Console to monitor the messages being written to the queue and the EM to execute the composite. In the Console, go to Services > Messaging > JMS Modules > TestJMSModule > TestJMSQueue > Monitoring. Note the number of messages under Messages Current. In the EM, go to SOA > soa-infra (soa_server1) > default (or wherever you deployed your composite to) and click on JmsAdapterWriteSchema [1.0], then press the Test button. Under Input Arguments, enter any string into the text input field for the payload, for example Test Message then press Test Web Service. If the instance is successful you should see the same text in the Response message, “Test Message”. In the Console, refresh the Monitoring screen to confirm a new message has been written to the queue. Check the checkbox and press Show Messages. Click on the newest message and view its contents. They should include the full XML of the entered payload. 7. Troubleshooting If you get an exception similar to the following at runtime ... BINDING.JCA-12510 JCA Resource Adapter location error. Unable to locate the JCA Resource Adapter via .jca binding file element The JCA Binding Component is unable to startup the Resource Adapter specified in the element: location='eis/wls/QueueTest'. The reason for this is most likely that either 1) the Resource Adapters RAR file has not been deployed successfully to the WebLogic Application server or 2) the '' element in weblogic-ra.xml has not been set to eis/wls/QueueTest. In the last case you will have to add a new WebLogic JCA connection factory (deploy a RAR). Please correct this and then restart the Application Server at oracle.integration.platform.blocks.adapter.fw.AdapterBindingException. createJndiLookupException(AdapterBindingException.java:130) at oracle.integration.platform.blocks.adapter.fw.jca.cci. JCAConnectionManager$JCAConnectionPool.createJCAConnectionFactory (JCAConnectionManager.java:1387) at oracle.integration.platform.blocks.adapter.fw.jca.cci. JCAConnectionManager$JCAConnectionPool.newPoolObject (JCAConnectionManager.java:1285) ... then this is very likely due to an incorrect JNDI name entered for the JMS Connection in the JMS Adapter Wizard. Recheck those steps. The error message prints the name of the JNDI name used. In this example, it was incorrectly entered as eis/wls/QueueTest instead of eis/wls/TestQueue. This concludes this example. Best regards John-Brown Evans Oracle Technology Proactive Support Delivery

    Read the article

  • How to send messages between c++ .dll and C# app using named pipe?

    - by Gal
    I'm making an injected .dll written in C++, and I want to communicate with a C# app using named pipes. Now, I am using the built in System.IO.Pipe .net classes in the C# app, and I'm using the regular functions in C++. I don't have much experience in C++ (Read: This is my first C++ code..), tho I'm experienced in C#. It seems that the connection with the server and the client is working, the only problem is the messaged aren't being send. I tried making the .dll the server, the C# app the server, making the pipe direction InOut (duplex) but none seems to work. When I tried to make the .dll the server, which sends messages to the C# app, the code I used was like this: DWORD ServerCreate() // function to create the server and wait till it successfully creates it to return. { hPipe = CreateNamedPipe(pipename,//The unique pipe name. This string must have the following form: \\.\pipe\pipename PIPE_ACCESS_DUPLEX, PIPE_TYPE_MESSAGE | PIPE_READMODE_MESSAGE | PIPE_NOWAIT, //write and read and return right away PIPE_UNLIMITED_INSTANCES,//The maximum number of instances that can be created for this pipe 4096 , // output time-out 4096 , // input time-out 0,//client time-out NULL); if(hPipe== INVALID_HANDLE_VALUE) { return 1;//failed } else return 0;//success } void SendMsg(string msg) { DWORD cbWritten; WriteFile(hPipe,msg.c_str(), msg.length()+1, &cbWritten,NULL); } void ProccesingPipeInstance() { while(ServerCreate() == 1)//if failed { Sleep(1000); } //if created success, wait to connect ConnectNamedPipe(hPipe, NULL); for(;;) { SendMsg("HI!"); if( ConnectNamedPipe(hPipe, NULL)==0) if(GetLastError()==ERROR_NO_DATA) { DebugPrintA("previous closed,ERROR_NO_DATA"); DisconnectNamedPipe(hPipe); ConnectNamedPipe(hPipe, NULL); } Sleep(1000); } And the C# cliend like this: static void Main(string[] args) { Console.WriteLine("Hello!"); using (var pipe = new NamedPipeClientStream(".", "HyprPipe", PipeDirection.In)) { Console.WriteLine("Created Client!"); Console.Write("Connecting to pipe server in the .dll ..."); pipe.Connect(); Console.WriteLine("DONE!"); using (var pr = new StreamReader(pipe)) { string t; while ((t = pr.ReadLine()) != null) { Console.WriteLine("Message: {0}",t); } } } } I see that the C# client connected to the .dll, but it won't receive any message.. I tried doing it the other way around, as I said before, and trying to make the C# send messages to the .dll, which would show them in a message box. The .dll was injected and connected to the C# server, but when It received a message it just crashed the application it was injected to. Please help me, or guide me on how to use named pipes between C++ and C# app

    Read the article

  • Injecting generics with Guice

    - by paradigmatic
    I am trying to migrate a small project, replacing some factories with Guice (it is my first Guice trial). However, I am stuck when trying to inject generics. I managed to extract a small toy example with two classes and a module: import com.google.inject.Inject; public class Console<T> { private final StringOutput<T> out; @Inject public Console(StringOutput<T> out) { this.out = out; } public void print(T t) { System.out.println(out.converter(t)); } } public class StringOutput<T> { public String converter(T t) { return t.toString(); } } import com.google.inject.AbstractModule; import com.google.inject.Guice; import com.google.inject.Injector; import com.google.inject.TypeLiteral; public class MyModule extends AbstractModule { @Override protected void configure() { bind(StringOutput.class); bind(Console.class); } public static void main(String[] args) { Injector injector = Guice.createInjector( new MyModule() ); StringOutput<Integer> out = injector.getInstance(StringOutput.class); System.out.println( out.converter(12) ); Console<Double> cons = injector.getInstance(Console.class); cons.print(123.0); } } When I run this example, all I got is: Exception in thread "main" com.google.inject.CreationException: Guice creation errors: 1) playground.StringOutput<T> cannot be used as a key; It is not fully specified. at playground.MyModule.configure(MyModule.java:15) 1 error at com.google.inject.internal.Errors.throwCreationExceptionIfErrorsExist(Errors.java:354) at com.google.inject.InjectorBuilder.initializeStatically(InjectorBuilder.java:152) at com.google.inject.InjectorBuilder.build(InjectorBuilder.java:105) at com.google.inject.Guice.createInjector(Guice.java:92) I tried looking for the error message, but without finding any useful hints. Further on the Guice FAQ I stumble upon a question about how to inject generics. I tried to add the following binding in the configure method: bind(new TypeLiteral<StringOutput<Double>>() {}).toInstance(new StringOutput<Double>()); But without success (same error message). Can someone explain me the error message and provide me some tips ? Thanks.

    Read the article

  • .NET 1.0 ThreadPool Question

    - by dotnet-practitioner
    I am trying to spawn a thread to take care of DoWork task that should take less than 3 seconds. Inside DoWork its taking 15 seconds. I want to abort DoWork and transfer the control back to main thread. I have copied the code as follows and its not working. Instead of aborting DoWork, it still finishes DoWork and then transfers the control back to main thread. What am I doing wrong? class Class1 { /// <summary> /// The main entry point for the application. /// </summary> /// private static System.Threading.ManualResetEvent[] resetEvents; [STAThread] static void Main(string[] args) { resetEvents = new ManualResetEvent[1]; int i = 0; resetEvents[i] = new ManualResetEvent(false); ThreadPool.QueueUserWorkItem(new WaitCallback(DoWork),(object)i); Thread.CurrentThread.Name = "main thread"; Console.WriteLine("[{0}] waiting in the main method", Thread.CurrentThread.Name); DateTime start = DateTime.Now; DateTime end ; TimeSpan span = DateTime.Now.Subtract(start); //abort dowork method if it takes more than 3 seconds //and transfer control to the main thread. do { if (span.Seconds < 3) WaitHandle.WaitAll(resetEvents); else resetEvents[0].Set(); end = DateTime.Now; span = end.Subtract(start); }while (span.Seconds < 2); Console.WriteLine(span.Seconds); Console.WriteLine("[{0}] all done in the main method",Thread.CurrentThread.Name); Console.ReadLine(); } static void DoWork(object o) { int index = (int)o; Thread.CurrentThread.Name = "do work thread"; //simulate heavy duty work. Thread.Sleep(15000); //work is done.. resetEvents[index].Set(); Console.WriteLine("[{0}] do work finished",Thread.CurrentThread.Name); } }

    Read the article

< Previous Page | 56 57 58 59 60 61 62 63 64 65 66 67  | Next Page >