Search Results

Search found 23084 results on 924 pages for 'jeff main'.

Page 628/924 | < Previous Page | 624 625 626 627 628 629 630 631 632 633 634 635  | Next Page >

  • Ipsec config problem // openswan

    - by user90696
    I try to configure Ipsec on server with openswan as client. But receive error - possible, it's auth error. What I wrote wrong in config ? Thank you for answers. #1: STATE_MAIN_I2: sent MI2, expecting MR2 003 "f-net" #1: received Vendor ID payload [Cisco-Unity] 003 "f-net" #1: received Vendor ID payload [Dead Peer Detection] 003 "f-net" #1: ignoring unknown Vendor ID payload [ca917959574c7d5aed4222a9df367018] 003 "f-net" #1: received Vendor ID payload [XAUTH] 108 "f-net" #1: STATE_MAIN_I3: sent MI3, expecting MR3 003 "f-net" #1: discarding duplicate packet; already STATE_MAIN_I3 010 "f-net" #1: STATE_MAIN_I3: retransmission; will wait 20s for response 003 "f-net" #1: discarding duplicate packet; already STATE_MAIN_I3 003 "f-net" #1: discarding duplicate packet; already STATE_MAIN_I3 003 "f-net" #1: discarding duplicate packet; already STATE_MAIN_I3 010 "f-net" #1: STATE_MAIN_I3: retransmission; will wait 40s for response 031 "f-net" #1: max number of retransmissions (2) reached STATE_MAIN_I3. Possible authentication failure: no acceptable response to our first encrypted message 000 "f-net" #1: starting keying attempt 2 of at most 3, but releasing whack other side - Cisco ASA. parameters for my connection on our Linux server : VPN Gateway 8.*.*.* (Cisco ) Phase 1 Exchange Type Main Mode Identification Type IP Address Local ID 4.*.*.* (our Linux server IP) Remote ID 8.*.*.* (VPN server IP) Authentication PSK Pre Shared Key Diffie-Hellman Key Group DH 5 (1536 bit) or DH 2 (1024 bit) Encryption Algorithm AES 256 HMAC Function SHA-1 Lifetime 86.400 seconds / no volume limit Phase 2 Security Protocol ESP Connection Mode Tunnel Encryption Algorithm AES 256 HMAC Function SHA-1 Lifetime 3600 seconds / 4.608.000 kilobytes DPD / IKE Keepalive 15 seconds PFS off Remote Network 192.168.100.0/24 Local Network 1 10.0.0.0/16 ............... Local Network 5 current openswan config : # config setup klipsdebug=all plutodebug="control parsing" protostack=netkey nat_traversal=no virtual_private=%v4:10.0.0.0/8,%v4:192.168.0.0/16,%v4:172.16.0.0/12 oe=off nhelpers=0 conn f-net type=tunnel keyexchange=ike authby=secret auth=esp esp=aes256-sha1 keyingtries=3 pfs=no aggrmode=no keylife=3600s ike=aes256-sha1-modp1024 # left=4.*.*.* leftsubnet=10.0.0.0/16 leftid=4.*.*.* leftnexthop=%defaultroute right=8.*.*.* rightsubnet=192.168.100.0/24 rightid=8.*.*.* rightnexthop=%defaultroute auto=add

    Read the article

  • Ubuntu Server running VNC

    - by xwapilot
    I have access to four computers: 1 Ubuntu Server desktop (Version 10.04) 1 Mac Mini (Snow Leopard) 1 Windows desktop (Windows 7) 1 Windows laptop (Windows Vista) The first three will always be on the home network. My goal is to SSH from the laptop into the server and be able, through VNC (or another remote desktop software), to control the windows and mac computers. The goal of this would be a slightly heightened network security over using VNC to directly access the mac or windows desktop. I have successfully used SSH to connect to the server, but have not been able to successfully implement the remote desktop connection. I would appreciate help doing so. Here's what I've done so far: As per instructions here: http://www.stuartellis.eu/articles/vnc-on-linux/ I installed the following: vnc4server – the main VNC server software vnc-java – enables access from Web browsers with Java support xvnc4viewer – a basic VNC viewer I then set up a password using the vncpasswd command. To attempt to connect to the mac, I followed directions I found in a thread at superuser. com and went to "System PreferencesSharing" and enabled "Screen Sharing". Subsequently, I tried entering the following commands into Ubuntu: vncviewer mac_ip_address::5904 vncviewer mac_ip_address:0 vncviewer mac_ip_address:1 They all returned the following: VNC Viewer Free Edition 4.1.1 for X - built Apr 9 2010 18:41:55 Copyright (C) 2002-2005 RealVNC Ltd. See http ://www .realvnc. com for information on VNC. vncviewer: unable to open display "" I'm sure I'm missing something important, but I'm not sure what it is. Do I need to have a GUI installed, or did that come with the vnc packages I installed?

    Read the article

  • Can you use SQLite 64 bit odbc from powershell

    - by Levin Magruder
    Basically, my question is "Does this combo work for anyone," and, "Can you see what I am doing wrong" I have installed 64 bit ODBC driver for sqlite, downloaded from this page. I am running powershell version 2 on window 7. In ODBC configuration I create a system DSN with name LoveBoat, pointing at a valid file. I don't have any "real" apps to test whether the ODBC connection works, but a simple program I list below works. However, with PowerShell, which is what I want: $x = new-object System.Data.Odbc.OdbcConnection("DSN=LoveBoat") $x.open() That yields the error: Exception calling "Open" with "0" argument(s): "The type initializer for 'System.Transactions.Diagnostics.DiagnosticTrace' threw an exception." At line:1 char:8 + $x.Open <<<< () + CategoryInfo : NotSpecified: (:) [], MethodInvocationException + FullyQualifiedErrorId : DotNetMethodException On the other hand the test program below runs and prints out the expected data. using System.Data.Odbc; using System.Data; using System; public class program { public static void Main(string[] args) { OdbcConnection conn = new OdbcConnection(@"DSN=LoveBoat"); conn.Open(); OdbcCommand comm = new OdbcCommand(); comm.CommandText= "SELECT Name From Myfavoritetable"; comm.Connection = conn; OdbcDataReader myReader = comm.ExecuteReader(CommandBehavior.CloseConnection); while(myReader.Read()) { Console.WriteLine(myReader[0]); } } }

    Read the article

  • PECL install error after upgrading to OSX 10.8

    - by Clive
    I've just upgraded my OS to Mountain Lion and PECL is no longer working (it's on a test drive so no drama, but I'd like to get it working so I can upgrade the OS on my shiny new SSD as well). I'm using the native PHP installation, no macports/homebrew or anything like that. Running sudo pecl install uploadprogress (for example) produces the following terminal output: downloading uploadprogress-1.0.3.1.tgz ... Starting to download uploadprogress-1.0.3.1.tgz (9,040 bytes) .....done: 9,040 bytes 4 source files, building running: phpize grep: /usr/include/php/main/php.h: No such file or directory grep: /usr/include/php/Zend/zend_modules.h: No such file or directory grep: /usr/include/php/Zend/zend_extensions.h: No such file or directory Configuring for: PHP Api Version: Zend Module Api No: Zend Extension Api No: autom4te: need GNU m4 1.4 or later: /usr/bin/m4 ERROR: `phpize' failed I'm guessing the problem is the 3 grep lines. I've found several threads that suggest this is caused by XCode not being installed...but XCode is installed, and updated to the latest version (4.4). All the relevant symlinks to /Developer/usr/bin/* also exist as they should. m4 is currently at version: m4 (GNU M4) 1.4.13, so even though the output above contains a line pertaining to it, I don't think that can be the problem. I'm sure it's just a simple issue, anyone got any clues?

    Read the article

  • postfix Mail filters not running behind a controlled enviornment

    - by Ashish
    Hi, I have deployed a postfix server for email receiving. On this I have configured SenderID + SPF milter, by referring to http://www.postfix.org/MILTER_README.html The command that I used is as follows: ./sid-filter -u postfix -p inet:10027@localhost -l Following are my settings in main.cf file: #Milter support for smtpd mail smtpd_milters = inet:localhost:10027, inet:localhost:10028 # Milters for non-SMTP mail. non_smtpd_milters = inet:localhost:10027, inet:localhost:10028 milter_default_action = reject # Postfix . 2.6 #milter_protocol = 6 # 2.3 . Postfix . 2.5 milter_protocol = 2 Now I have this observation: One of the postfix that is setup on AWS CentOS 5.5 is working fine and is able to receive mails on defined mx record. One of the similar postfix(as in step 1) that is setup behind one of the corporate firewalls is not able to receive any mails and is giving following type of error logs: connect from xxxxxx.austin.hp.com[xx.xxx.96.198] May 25 13:20:02 g2t0385g postfix/smtpd[11733]: C11F9B0194: client=xxxxxxx.austin.hp.com[15.217.96.198] May 25 13:20:03 g2t0385g postfix/cleanup[11814]: C11F9B0194: message-id= May 25 13:20:03 g2t0385g postfix/cleanup[11814]: C11F9B0194: milter-reject: END-OF-MESSAGE from xxxxxx.austin.hp.com[xx.xxx.96.198]: 5.7.1 Command rejected; from= to= proto=ESMTP helo= Here the 'sid-filter' is giving problems. Any idea, what I am doing wrong? Please help. Thanks in advance Ashish Sharma

    Read the article

  • Route specific HTTP requests through pfSense OpenVPN

    - by DennisQ
    Hi, to start, I have very little knowledge on routes, iptables, etc. That said, here's what I'm trying to accomplish and where I think I'm stumped: Problem: We have an external website which we recently firewalled so it only accepts traffic from our office IP addresses. This works well at the office, but doesn't work for remote access through VPN as we don't route all traffic through OpenVPN. I would rather avoid forcing everyone to route all traffic through just to accommodate this one site. Environment: Main router box is running pfSense. Em0 is internal IP, Em1 is external. Internal net is 10.23.x and VPN is 10.0.8.0/24 I believe what I need to do is add a route to the VPN server config to send all traffic to that IP over the VPN tunnel. I think that part's working, but I don't get a response back, so I'm assuming that I need some NAT config on the VPN server to route the response back over the tunnel? What I've found so far is to try the following, but since this is a pfSense box on FreeBSD, I can't run iptables, etc. Make sure ip forwarding is enabled: echo 1 /proc/sys/net/ipv4/ip_forward Setup NAT back out: iptables -t nat -A POSTROUTING -s 10.0.8.0/24 -o em0 -j MASQUERADE Am I on the right path, and if so how do I accomplish this through pfSense UI or FreeBSD CLI? Thanks!

    Read the article

  • Syncing Music Everywhere with Google Music and iTunes Match - Will This Work?

    - by dragonmantank
    I have the following devices: Personal Laptop running Windows 7/Ubuntu 11.10 (mostly use Ubuntu) Media Server running Windows 7 with PS3 Media Server and iTunes Work Laptop running OSX Snow Leopard iPad iPhone 4S The iPhone just replaced my Droid 2 Global. What I had been doing was using Google Music to watch the folders iTunes was storing music in and moving any new files up to Google Music. The Droid would pull music down from the cloud via streaming or me telling it to make it available offline, I had folders set up with PS3 Media Server to stream them to TV's via DLNA, and used RDP to play music through my speakers in the office. So far it's worked well. Since I've replaced the Droid 2 though with an iPhone, I've lost the syncing ability with Google Music and have to do it via iTunes (I knew this would happen, no big suprise). I got to thinking though - Apple does offer iTunes Match, which allows your devices to stream/download the music from 'the cloud,' much like Google Music. I could then listen to whatever I Wanted (for the most part) on my phone, iPad, and laptops by syncing via iTunes Match. I don't want to loose my MP3s though, and since I've never used iTunes Match, I wonder if the following is a viable solution: Sign up for iTunes Match on my media server Let it scan my library and make available my songs in AAC in the cloud Not delete the media server MP3s Set up other devices to sync to iTunes Match Continue to get MP3s via Amazon or other services and add to iTunes Let the MP3s sync to Google Music, and let the MP3's add to the AAC versions on my devices I think the main kicker is I don't want to lose the MP3 versions of my songs as those will work just fine on all my devices and I generally rip at 320kbps. I don't mind spending $25/year if it means that I can easily shift the music from device to device without much thinking, but I'm not going to pay $25/year to end up converting my library over to AAC just to save myself the hassle of manually syncing my iPad and iPhone.

    Read the article

  • How to configure postfix for per-sender SASL authentication

    - by Marwan
    I have two gmail accounts, and I want to configure my local postfix server as a client which does SASL authentication with smtp.gmail.com:587 with credentials that depend on the sender address. So, let's say that my gmail accounts are: [email protected] and [email protected]. If I sent a mail with [email protected] in the FROM header field, then postfix should use the credentials: [email protected]:psswd1 to do SASL authentication with gmail SMTP server. Similarly with [email protected], it should use [email protected]:passwd2. Sounds fairly simple. Well, I followed the postfix official documentation at http://www.postfix.org/SASL_README.html, and I ended up with the following relevant configurations: /etc/postfix/main.cf smtp_sasl_auth_enable = yes smtp_sasl_security_options = noanonymous smtp_sasl_password_maps = hash:/etc/postfix/sasl_passwd smtp_sender_dependent_authentication = yes sender_dependent_relayhost_maps = hash:/etc/postfix/sender_relay smtp_tls_security_level = secure smtp_tls_CAfile = /etc/ssl/certs/Equifax_Secure_CA.pem smtp_tls_CApath = /etc/ssl/certs smtp_tls_session_cache_database = btree:/etc/postfix/smtp_scache smtp_tls_session_cache_timeout = 3600s smtp_tls_loglevel = 1 tls_random_source = dev:/dev/urandom relayhost = smtp.gmail.com:587 /etc/postfix/sasl_passwd [email protected] [email protected]:passwd1 [email protected] [email protected]:passwd2 smtp.gmail.com:587 [email protected]:passwd1 /etc/postfix/sender_relay [email protected] smtp.gmail.com:587 [email protected] smtp.gmail.com:587 After I'm done with the configurations I did: $ postmap /etc/postfix/sasl_passwd $ postmap /etc/postfix/sender_relay $ /etc/init.d/postfix restart The problem is that when I send a mail from [email protected], the message ends up in the destination with sender address [email protected] and NOT [email protected], which means that postfix always ignores the per-sender configurations and send the mail using the default credentials (the third line in /etc/postfix/sasl_passwd above). I checked the configurations multiple times and even compared them to those in various blog posts addressing the same issue but found them to be more or less the same as mine. So, can anyone point me in the right direction, in case I'm missing something? Many thanks.

    Read the article

  • installing SVN - CentOS - cannot find -lexpat

    - by furnace
    Hey guys, I'm trying to install SVN on CentOS 5. Unfortunately a simple yum install isn't going to work (afaik) because I'm using the DirectAdmin control panel. When it comes to running 'make' I get this error: /usr/bin/ld: cannot find -lexpat I'm new to installing things without yum (!) so am a bit lost. Do you have any advice on how to get past this hurdle? Just to give a little more context to the error; /apache -I/usr/include/apache -I/etc/svn-install/subversion-1.6.2/sqlite-amalgamation -o subversion/svn/util.o -c subversion/svn/util.c cd subversion/svn && /bin/sh /etc/svn-install/subversion-1.6.2/libtool --tag=CC --silent --mode=link gcc -g -O2 -g -O2 -pthread -rpath /usr/lib -o svn add-cmd.o blame-cmd.o cat-cmd.o changelist-cmd.o checkout-cmd.o cleanup-cmd.o commit-cmd.o conflict-callbacks.o copy-cmd.o delete-cmd.o diff-cmd.o export-cmd.o help-cmd.o import-cmd.o info-cmd.o list-cmd.o lock-cmd.o log-cmd.o main.o merge-cmd.o mergeinfo-cmd.o mkdir-cmd.o move-cmd.o notify.o propdel-cmd.o propedit-cmd.o propget-cmd.o proplist-cmd.o props.o propset-cmd.o resolve-cmd.o resolved-cmd.o revert-cmd.o status-cmd.o status.o switch-cmd.o tree-conflicts.o unlock-cmd.o update-cmd.o util.o ../../subversion/libsvn_client/libsvn_client-1.la ../../subversion/libsvn_wc/libsvn_wc-1.la ../../subversion/libsvn_ra/libsvn_ra-1.la ../../subversion/libsvn_delta/libsvn_delta-1.la ../../subversion/libsvn_diff/libsvn_diff-1.la ../../subversion/libsvn_subr/libsvn_subr-1.la /etc/httpd/lib/libaprutil-1.la -lexpat /etc/httpd/lib/libapr-1.la -luuid -lrt -lcrypt -lpthread -ldl /usr/bin/ld: cannot find -lexpat collect2: ld returned 1 exit status make: *** [subversion/svn/svn] Error 1 Thanks!

    Read the article

  • sendmail.exe: Error during delivery. Service not available, closing transmission channel

    - by user2810332
    I have a module in my system that will trigger an email and send it to user. The email will be sent to user when the product in my system is going to expired soon. I test the whole module in localhost and there is no problem with it. Then, I finally moved the module in my server but it gives this error. sendmail: Error during delivery: Service not available, closing transmission channel. It will also create a notepad in my desktop that contains information like this : command line : C:\wamp\sendmail\sendmail.exe -t -i executable : sendmail.exe exec. date/time : 2011-06-18 01:10 compiled with : Delphi 2006/07 madExcept version : 3.0l callstack crc : $fecf9b34, $5562b2fa, $5562b2fa exception number : 1 exception class : EIdSMTPReplyError exception message : Service not available, closing transmission channel. main thread ($15b0): 0045918a +003e sendmail.exe IdReplySMTP 501 +1 TIdReplySMTP.RaiseReplyError 0043ff28 +0008 sendmail.exe IdTCPConnection 576 +0 TIdTCPConnection.RaiseExceptionForLastCmdResult 004402f4 +003c sendmail.exe IdTCPConnection 751 +10 TIdTCPConnection.CheckResponse 0043feba +002a sendmail.exe IdTCPConnection 565 +2 TIdTCPConnection.GetResponse 004403fd +002d sendmail.exe IdTCPConnection 788 +4 TIdTCPConnection.GetResponse 0045ab97 +0033 sendmail.exe IdSMTP 375 +4 TIdSMTP.Connect 004b5f14 +1060 sendmail.exe sendmail 808 +326 initialization 77013675 +0010 kernel32.dll BaseThreadInitThunk thread $cf8: 77a400e6 +0e ntdll.dll NtWaitForMultipleObjects 77013675 +10 kernel32.dll BaseThreadInitThunk thread $1088: 77a41ecf +0b ntdll.dll NtWaitForWorkViaWorkerFactory 77013675 +10 kernel32.dll BaseThreadInitThunk May I know what is the problem of this error ? Is it something like firewall in the server that block my sendmail.exe or anything else ? FYI, I'm using Wamp and Sendmail to send the email. This is my first time seeing error like this. I need an explanation on this. Thank you.

    Read the article

  • How do I provide dpkg configuration parameters to aptitude or apt-get?

    - by troutwine
    When installing gitolite I find that: # aptitude install gitolite The following NEW packages will be installed: gitolite 0 packages upgraded, 1 newly installed, 0 to remove and 29 not upgraded. Need to get 114 kB of archives. After unpacking 348 kB will be used. Get:1 http://security.debian.org/ squeeze/updates/main gitolite all 1.5.4-2+squeeze1 [114 kB] Fetched 114 kB in 0s (202 kB/s) Preconfiguring packages ... Selecting previously deselected package gitolite. (Reading database ... 30593 files and directories currently installed.) Unpacking gitolite (from .../gitolite_1.5.4-2+squeeze1_all.deb) ... Setting up gitolite (1.5.4-2+squeeze1) ... No adminkey given - not initializing gitolite in /var/lib/gitolite. The last line is of interest to me. If I run dpkg-reconfigure -plow gitolite I am presented with a dialog and can modify: the system user name for gitolite, the location of the gitolite repositories and provide the admin pubkey. I'd prefer to use the git system user and provide the admin pubkey on installation, say something of the sort: # aptitude install gitolite --user git --admin-pubkey 'ssh-rsa AAAAB3NzaC1yc2EAAAADAQABAAACAQDAc7kCAi2WkvqpAL1fK1sIw6xjpatJ+Ms2nrwLJPhdovEY3MPZF7mtH+rv1CHFDn66fLGiWevOFp...' That, of course, doesn't work. Can something similar be done? How do I determine the configuration parameters ahead of time? This would be remarkably useful, for instance, when installing gitolite automatically, via puppet or chef.

    Read the article

  • CentOS 5.5 ext4 conversion problem - ext4 partition is recognized as ext3

    - by FractalizeR
    Hello. I had 5.4 machine. Upgraded to 5.5 today via yum upgrade. All went fine. Rebooted. Wanted to convert root partition to ext4 (I have three partitions: /boot, / and swap). All of them on software RAID 1 (root is /dev/md2). I did the following for converting yum install e4fsprogs tune2fs -O extents,uninit_bg,dir_index /dev/md2 nano /etc/fstab # I indicated here that my /dev/md2 is of ext4 uname -a mkinitrd -f /boot/initrd-2.6.18-194.3.1.el5.img 2.6.18-194.3.1.el5 Rebooted. I expected fsck to start automatically as said on some site. But it did not. Threw some error (don't remember exactly which). Ok, I booted linux rescue and executed fsck: fsck -t ext4 -fy /dev/md2 Partition went fine. But still when I boot main system, it says in log: "ext3-fs:" then something about not being able to mount ext3 partition due to unknown extended attributed (200). I booted linux rescue again. It loads fine and correctly determines all my machine partitions both ext3 (boot) and ext4 (/) under /mnt/sysimage just fine. I retried mkinitrd thing again watching it's output and ensured ext4 module is included into the system. I also edited menu.lst grub file to include rootfstype=ext4 kernel parameter. Bad luck. I still have message from ext3-fs about not being able to mount filesystem because of attributes and kernel panic immediately after. I checked /etc/fstab - it's fine and saying that root is of ext4. What did I do wrong? This machine is empty so I can just reformat it with 5.5 and recreate partitions to be originally ext4. But... I just want to know what did I do wrong.

    Read the article

  • Why can’t two programs access my webcam simultaneously?

    - by qdii
    I first launch cheese and my webcam turns on. I then run vlc to grab the output of /dev/video0 but it fails with: [0x7f3ea40012e8] v4l2 demux error: cannot set input 0: Device or resource busy [0x7f3ea40012e8] v4l2 demux error: cannot set input 0: Device or resource busy [0x7f3ea4002168] v4l2 access error: cannot set input 0: Device or resource busy [0x7f3ea4002168] v4l2 access error: cannot set input 0: Device or resource busy [0x7f3eb4000b78] main input error: open of `v4l2:///dev/video0' failed Whatever pair of video programs I run (skype, cheese, vlc, etc.), the result is always the same: the second program can no longer use the webcam when the first one has already grabbed the output. However I find it curious as video4linux states: In general, V4L2 devices can be opened more than once. When this is supported by the driver, users can for example start a "panel" application to change controls like brightness or audio volume, while another application captures video and audio. My webcam is seen in lspci as 058f:a014 Alcor Micro Corp. Asus Integrated Webcam, but I don’t even know what the underlying driver is, so I can’t check whether my problem is driver-related or not. Any input would be more than welcome!

    Read the article

  • Exchange 2007 restore - Backup Exec Unable to Attach to a resource

    - by Andy
    I have been struggling with this one for months! Grateful for any advice. The setup is a windows 2003 server network, 4xservers on the domain. Two exchange 2007 servers (only one with mailboxes still on). Backup Exec (12.5) on a non-exchange server with agents on the others. Backup exec runs a full backup of exchange across the network well, at pretty reasonable speeds. However, when you try any kind of restore (individual emails, mailboxes or whole system restore - all to same location or to alternate server, RSG etc) the following message is received within about 10-15 secs of starting the job: Job ended: 24 December 2010 at 13:28:32 Completed status: Failed Final error: 0xe000848c - Unable to attach to a resource. Make sure that all selected resources exist and are online, and then try again. If the server or resource no longer exists, remove it from the selection list. Edit the selection list properties, click the View Selection Details tab, and then remove the resource. Final error category: Resource Errors For additional information regarding this error refer to link V-79-57344-33932 Things I have already tried: Changed account to main administrator account (with all permissions) checked versions of ese.dll on both servers - both the same Checked all VSS writers on both servers are stable / normal restoring to different locations Any advice anyone could give would be much appreciated. Many thanks, Andy

    Read the article

  • Site to Site VPN with Fault Tolerence

    - by Nordberg
    Hello, I have a situation where I require an IPSEC tunnel between two sites. Site 2 is a small branch office with basic (ADSL) connectivity and Site 1 is the "main" office with SDSL and ADSL for redundancy should the SDSL fail. From Site 1, all traffic bound for the 172.0.0.0 network will then be sent down another IPSEC tunnel to a supplier's Remote Server. See this page for the basic premise (this is a rough idea and things can be moved about etc...) I am considering specifying Cisco ASA devices as the firewalls for both sites for all connections. Would it be possible to employ something like HSRC to provide a backup at Site 1 should the SDSL go down? I suppose the key aims here are that Site 2 can somehow failover to initiate a VPN to the ASA behind the ADSL at Site 1. I will have a 21 subnet mask on all internet connections so can play with Class C routing if need be... If I'm barking up the wrong tree with HSRC, is there another way I can acheive this without massive expenditure on Barracuda routers et al? Many Thanks.

    Read the article

  • Weblogic 12 and the CLI

    - by Rig
    I am working with WebLogic on Fedora 19 and am attempting to use the CLI tools to no avail. It appears these were deprecated as far back as WebLogic 9 however I was assured they are still there and still functional. As it stands I have a need to use them if they are in fact functional. What appears to the case is that the weblogic jar file is not being loaded correctly to the classpath by this script after trying to manually add it to the classpath as it fails when trying to add those jars via java -classpath <path>. I've spent a lot of time so far trying to get this sorted out but I'm wondering what I may be missing here. My Java runtime is version 7, Fedora is 19, and WebLogic is 12.1. When I run env after running the provided set environment script it appears to have no impact from what I can see. (I'll add that later when I get back to that machine). I'm mostly a Windows developer so some of this is a topic I'm not well versed in. [foo@localhost bin]$ ./setDomainEnv.sh [foo@localhost bin]$ java weblogic.Admin -url t3://localhost:7001 -username <username> -password <password> HELP Error: Could not find or load main class weblogic.Admin [foo@localhost bin]$ ls -ltar total 72 drwxr-x--- 2 foo foo 4096 Jun 2 07:36 service_migration drwxr-x--- 2 foo foo 4096 Jun 2 07:36 server_migration drwxr-x--- 2 foo foo 4096 Jun 2 07:36 nodemanager -rwxr-x--- 1 foo foo 1267 Jun 2 07:36 setStartupEnv.sh -rwxr-x--- 1 foo foo 1105 Jun 2 07:36 startNodeManager.sh -rwxr-x--- 1 foo foo 5765 Jun 2 07:36 startWebLogic.sh -rwxr-x--- 1 foo foo 2001 Jun 2 07:36 stopWebLogic.sh -rwxr-x--- 1 foo foo 3170 Jun 2 07:36 startManagedWebLogic.sh -rwxr-x--- 1 foo foo 2776 Jun 2 07:36 stopManagedWebLogic.sh -rwxrwxrwx 1 foo foo 14136 Jun 2 07:36 setDomainEnv.sh -rwxr-x--- 1 foo foo 2060 Jun 2 07:36 startComponent.sh drwxr-x--- 5 foo foo 4096 Jun 2 07:36 . -rwxr-x--- 1 foo foo 1726 Jun 2 07:36 stopComponent.sh drwxr-x--- 12 foo foo 4096 Jun 2 07:45 ..

    Read the article

  • solr php extension fails to run on newest Debian Wheezy

    - by hijarian
    I'm trying to use the Solr PHP extension on the recently-upgraded Debian Wheezy. It installs both from PECL and from sources flawlessly but instead of giving me expected functionality it gives me this on every PHP run: PHP Warning: PHP Startup: Unable to load dynamic library '/usr/lib/php5/20100525/solr.so' - /usr/lib/php5/20100525/solr.so: undefined symbol: curl_easy_getinfo in Unknown on line 0 Also scripts which use the extension throws an error PHP Error[2]: include(SolrClient.php): failed to open stream: No such file or directory in file <...path to my autoloader...> My main point is that it was set up before and worked like a charm. In the upgrade among the relevant packages only the versions of PHP and libcurl was changed. Instance of Solr itself was left as is. I have all possible libcurl libraries: $ locate libcurl ... /usr/lib/x86_64-linux-gnu/libcurl-gnutls.so.3 /usr/lib/x86_64-linux-gnu/libcurl-gnutls.so.4 /usr/lib/x86_64-linux-gnu/libcurl-gnutls.so.4.2.0 /usr/lib/x86_64-linux-gnu/libcurl.a /usr/lib/x86_64-linux-gnu/libcurl.la /usr/lib/x86_64-linux-gnu/libcurl.so /usr/lib/x86_64-linux-gnu/libcurl.so.3 /usr/lib/x86_64-linux-gnu/libcurl.so.4 /usr/lib/x86_64-linux-gnu/libcurl.so.4.2.0 ... /usr/lib32/libcurl.so.3 /usr/lib32/libcurl.so.4 /usr/lib32/libcurl.so.4.2.0 ... I have instaled the php5-curl package version 5.4.4-2 with aptitude. I installed the Sorl extensions both with sudo pecl install solr (with various combinations of -f and -n flags and tried solr-beta too) and with wget ... cd ... phpize ./configure make make install I'm installing the 1.0.2 version of extension because it worked before the upgrade from Squeeze to Wheezy. As I said earlier, extension installs without any errors. I have already added the extension=solr.so incantation to the /etc/php5/mods-available/solr.ini What magic should I do to make solr extension work? Is this true that the only solution that I have is to downgrade the libcurl version as it was before the upgrade?

    Read the article

  • I need advice about iscsi + zfs(or ntfs) + windows 2008 clustering

    - by Fatih
    I want to setup a storage farm with iSCSI. I have 2 cluster node machine, 1 iscsi target machine that has 8TB installed as RAID 10. The capacity is now 8TB, but I'll upgrade the capacity in future. Let's say, I installed clusters as file server, and I connected these servers to iscsi target, then I shared 8TB capacity as an only folder to the windows users. Users now see only a folder whose capacity is 8TB. But if I want to add another 8TB to expand the main capacity, the users must not see the second folder for this new 8 TB. The users must see only a folder as before, but this time this folder's capacity expanded to 16TB. And so on, if I add another 8TB, the users must deal with only a folder. For this purpose, I've learnt that ZFS can expand its size without a problem. So if I use ZFS as a file system on iSCSI luns, how can the cluster machines see the ZFS. Because the cluster machines have windows 2008. Is there another way to expand the size of shared folder without a problem? Does ntfs support it?

    Read the article

  • NGINX MIME TYPE

    - by justanotherprogrammer
    I have my nginx conf file so that when ever a mobile device visits my site the url gets rewritten to m.mysite.com I did it by adding the following set $mobile_rewrite do_not_perform; if ($http_user_agent ~* "android.+mobile|avantgo|bada\/|blackberry|blazer|compal|elaine|fennec|hiptop|iemobile|ip(hone|od)|iris|kindle|lge |maemo|midp|mmp|netfront|opera m(ob|in)i|palm( os)?|phone|p(ixi|re)\/|plucker|pocket|psp|symbian|treo|up\.(browser|link)|vodafone|wap|windows (ce|phone)|xda|xiino") { set $mobile_rewrite perform; } if ($http_user_agent ~* "^(1207|6310|6590|3gso|4thp|50[1-6]i|770s|802s|a wa|abac|ac(er|oo|s\-)|ai(ko|rn)|al(av|ca|co)|amoi|an(ex|ny|yw)|aptu|ar(ch|go)|as(te|us)|attw|au(di|\-m|r |s )|avan|be(ck|ll|nq)|bi(lb|rd)|bl(ac|az)|br(e|v)w|bumb|bw\-(n|u)|c55\/|capi|ccwa|cdm\-|cell|chtm|cldc|cmd\-|co(mp|nd)|craw|da(it|ll|ng)|dbte|dc\-s|devi|dica|dmob|do(c|p)o|ds(12|\-d)|el(49|ai)|em(l2|ul)|er(ic|k0)|esl8|ez([4-7]0|os|wa|ze)|fetc|fly(\-|_)|g1 u|g560|gene|gf\-5|g\-mo|go(\.w|od)|gr(ad|un)|haie|hcit|hd\-(m|p|t)|hei\-|hi(pt|ta)|hp( i|ip)|hs\-c|ht(c(\-| |_|a|g|p|s|t)|tp)|hu(aw|tc)|i\-(20|go|ma)|i230|iac( |\-|\/)|ibro|idea|ig01|ikom|im1k|inno|ipaq|iris|ja(t|v)a|jbro|jemu|jigs|kddi|keji|kgt( |\/)|klon|kpt |kwc\-|kyo(c|k)|le(no|xi)|lg( g|\/(k|l|u)|50|54|e\-|e\/|\-[a-w])|libw|lynx|m1\-w|m3ga|m50\/|ma(te|ui|xo)|mc(01|21|ca)|m\-cr|me(di|rc|ri)|mi(o8|oa|ts)|mmef|mo(01|02|bi|de|do|t(\-| |o|v)|zz)|mt(50|p1|v )|mwbp|mywa|n10[0-2]|n20[2-3]|n30(0|2)|n50(0|2|5)|n7(0(0|1)|10)|ne((c|m)\-|on|tf|wf|wg|wt)|nok(6|i)|nzph|o2im|op(ti|wv)|oran|owg1|p800|pan(a|d|t)|pdxg|pg(13|\-([1-8]|c))|phil|pire|pl(ay|uc)|pn\-2|po(ck|rt|se)|prox|psio|pt\-g|qa\-a|qc(07|12|21|32|60|\-[2-7]|i\-)|qtek|r380|r600|raks|rim9|ro(ve|zo)|s55\/|sa(ge|ma|mm|ms|ny|va)|sc(01|h\-|oo|p\-)|sdk\/|se(c(\-|0|1)|47|mc|nd|ri)|sgh\-|shar|sie(\-|m)|sk\-0|sl(45|id)|sm(al|ar|b3|it|t5)|so(ft|ny)|sp(01|h\-|v\-|v )|sy(01|mb)|t2(18|50)|t6(00|10|18)|ta(gt|lk)|tcl\-|tdg\-|tel(i|m)|tim\-|t\-mo|to(pl|sh)|ts(70|m\-|m3|m5)|tx\-9|up(\.b|g1|si)|utst|v400|v750|veri|vi(rg|te)|vk(40|5[0-3]|\-v)|vm40|voda|vulc|vx(52|53|60|61|70|80|81|83|85|98)|w3c(\-| )|webc|whit|wi(g |nc|nw)|wmlb|wonu|x700|xda(\-|2|g)|yas\-|your|zeto|zte\-)") { set $mobile_rewrite perform; } if ($mobile_rewrite = perform) { rewrite ^ http://m.mywebsite.com redirect; break; } I got it from http://detectmobilebrowsers.com/ IT WORKS.But none of my images/js/css files load only the HTML. And I know its the chunk of code I mentioned above because when I remove it and visit m.mywebsite.com from my mobile device everything loads up.So this bit of code does SOMETHING to my css/img/js MIME TYPES. I found this out through the the console error messages from safari with the user agent set to iphone. text.cssResource interpreted as stylesheet but transferred with MIME type text/html. 960_16_col.cssResource interpreted as stylesheet but transferred with MIME type text/html. design.cssResource interpreted as stylesheet but transferred with MIME type text/html. navigation_menu.cssResource interpreted as stylesheet but transferred with MIME type text/html. reset.cssResource interpreted as stylesheet but transferred with MIME type text/html. slide_down_panel.cssResource interpreted as stylesheet but transferred with MIME type text/html. myrealtorpage_view.cssResource interpreted as stylesheet but transferred with MIME type text/html. head.jsResource interpreted as script but transferred with MIME type text/html. head.js:1SyntaxError: Parse error isaac:208ReferenceError: Can't find variable: head mrp_home_icon.pngResource interpreted as image but transferred with MIME type text/html. M_1_L_289_I_499_default_thumb.jpgResource interpreted as image but transferred with MIME type text/html. M_1_L_290_I_500_default_thumb.jpgResource interpreted as image but transferred with MIME type text/html. M_1_default.jpgResource interpreted as image but transferred with MIME type text/html. default_listing_image.pngResource interpreted as image but transferred with MIME type text/html. here is my whole nginx conf file just incase... worker_processes 1; events { worker_connections 1024; } http { include mime.types; include /etc/nginx/conf/fastcgi.conf; default_type application/octet-stream; sendfile on; keepalive_timeout 65; #server1 server { listen 80; server_name mywebsite.com www.mywebsite.com ; index index.html index.htm index.php; root /srv/http/mywebsite.com/public; access_log /srv/http/mywebsite.com/logs/access.log; error_log /srv/http/mywebsite.com/logs/error.log; #---------------- For CodeIgniter ----------------# # canonicalize codeigniter url end points # if your default controller is something other than "welcome" you should change the following if ($request_uri ~* ^(/main(/index)?|/index(.php)?)/?$) { rewrite ^(.*)$ / permanent; } # removes trailing "index" from all controllers if ($request_uri ~* index/?$) { rewrite ^/(.*)/index/?$ /$1 permanent; } # removes trailing slashes (prevents SEO duplicate content issues) if (!-d $request_filename) { rewrite ^/(.+)/$ /$1 permanent; } # unless the request is for a valid file (image, js, css, etc.), send to bootstrap if (!-e $request_filename) { rewrite ^/(.*)$ /index.php?/$1 last; break; } #---------------------------------------------------# #--------------- For Mobile Devices ----------------# set $mobile_rewrite do_not_perform; if ($http_user_agent ~* "android.+mobile|avantgo|bada\/|blackberry|blazer|compal|elaine|fennec|hiptop|iemobile|ip(hone|od)|iris|kindle|lge |maemo|midp|mmp|netfront|opera m(ob|in)i|palm( os)?|phone|p(ixi|re)\/|plucker|pocket|psp|symbian|treo|up\.(browser|link)|vodafone|wap|windows (ce|phone)|xda|xiino") { set $mobile_rewrite perform; } if ($http_user_agent ~* "^(1207|6310|6590|3gso|4thp|50[1-6]i|770s|802s|a wa|abac|ac(er|oo|s\-)|ai(ko|rn)|al(av|ca|co)|amoi|an(ex|ny|yw)|aptu|ar(ch|go)|as(te|us)|attw|au(di|\-m|r |s )|avan|be(ck|ll|nq)|bi(lb|rd)|bl(ac|az)|br(e|v)w|bumb|bw\-(n|u)|c55\/|capi|ccwa|cdm\-|cell|chtm|cldc|cmd\-|co(mp|nd)|craw|da(it|ll|ng)|dbte|dc\-s|devi|dica|dmob|do(c|p)o|ds(12|\-d)|el(49|ai)|em(l2|ul)|er(ic|k0)|esl8|ez([4-7]0|os|wa|ze)|fetc|fly(\-|_)|g1 u|g560|gene|gf\-5|g\-mo|go(\.w|od)|gr(ad|un)|haie|hcit|hd\-(m|p|t)|hei\-|hi(pt|ta)|hp( i|ip)|hs\-c|ht(c(\-| |_|a|g|p|s|t)|tp)|hu(aw|tc)|i\-(20|go|ma)|i230|iac( |\-|\/)|ibro|idea|ig01|ikom|im1k|inno|ipaq|iris|ja(t|v)a|jbro|jemu|jigs|kddi|keji|kgt( |\/)|klon|kpt |kwc\-|kyo(c|k)|le(no|xi)|lg( g|\/(k|l|u)|50|54|e\-|e\/|\-[a-w])|libw|lynx|m1\-w|m3ga|m50\/|ma(te|ui|xo)|mc(01|21|ca)|m\-cr|me(di|rc|ri)|mi(o8|oa|ts)|mmef|mo(01|02|bi|de|do|t(\-| |o|v)|zz)|mt(50|p1|v )|mwbp|mywa|n10[0-2]|n20[2-3]|n30(0|2)|n50(0|2|5)|n7(0(0|1)|10)|ne((c|m)\-|on|tf|wf|wg|wt)|nok(6|i)|nzph|o2im|op(ti|wv)|oran|owg1|p800|pan(a|d|t)|pdxg|pg(13|\-([1-8]|c))|phil|pire|pl(ay|uc)|pn\-2|po(ck|rt|se)|prox|psio|pt\-g|qa\-a|qc(07|12|21|32|60|\-[2-7]|i\-)|qtek|r380|r600|raks|rim9|ro(ve|zo)|s55\/|sa(ge|ma|mm|ms|ny|va)|sc(01|h\-|oo|p\-)|sdk\/|se(c(\-|0|1)|47|mc|nd|ri)|sgh\-|shar|sie(\-|m)|sk\-0|sl(45|id)|sm(al|ar|b3|it|t5)|so(ft|ny)|sp(01|h\-|v\-|v )|sy(01|mb)|t2(18|50)|t6(00|10|18)|ta(gt|lk)|tcl\-|tdg\-|tel(i|m)|tim\-|t\-mo|to(pl|sh)|ts(70|m\-|m3|m5)|tx\-9|up(\.b|g1|si)|utst|v400|v750|veri|vi(rg|te)|vk(40|5[0-3]|\-v)|vm40|voda|vulc|vx(52|53|60|61|70|80|81|83|85|98)|w3c(\-| )|webc|whit|wi(g |nc|nw)|wmlb|wonu|x700|xda(\-|2|g)|yas\-|your|zeto|zte\-)") { set $mobile_rewrite perform; } if ($mobile_rewrite = perform) { rewrite ^ http://m.mywebsite.com redirect; #rewrite ^(.*)$ $scheme://mywebsite.com/mobile/$1; #return 301 http://m.mywebsite.com; #break; } #---------------------------------------------------# location / { index index.html index.htm index.php; } error_page 500 502 503 504 /50x.html; location = /50x.html { root html; } location ~ \.php$ { try_files $uri =404; fastcgi_pass 127.0.0.1:9000; fastcgi_index index.php; fastcgi_param SCRIPT_FILENAME $document_root$fastcgi_script_name; fastcgi_param PATH_INFO $fastcgi_script_name; include /etc/nginx/conf/fastcgi_params; } }#sever1 #server 2 server { listen 80; server_name m.mywebsite.com; index index.html index.htm index.php; root /srv/http/mywebsite.com/public; access_log /srv/http/mywebsite.com/logs/access.log; error_log /srv/http/mywebsite.com/logs/error.log; #---------------- For CodeIgniter ----------------# # canonicalize codeigniter url end points # if your default controller is something other than "welcome" you should change the following if ($request_uri ~* ^(/main(/index)?|/index(.php)?)/?$) { rewrite ^(.*)$ / permanent; } # removes trailing "index" from all controllers if ($request_uri ~* index/?$) { rewrite ^/(.*)/index/?$ /$1 permanent; } # removes trailing slashes (prevents SEO duplicate content issues) if (!-d $request_filename) { rewrite ^/(.+)/$ /$1 permanent; } # unless the request is for a valid file (image, js, css, etc.), send to bootstrap if (!-e $request_filename) { rewrite ^/(.*)$ /index.php?/$1 last; break; } #---------------------------------------------------# location / { index index.html index.htm index.php; } error_page 500 502 503 504 /50x.html; location = /50x.html { root html; } location ~ \.php$ { try_files $uri =404; fastcgi_pass 127.0.0.1:9000; fastcgi_index index.php; fastcgi_param SCRIPT_FILENAME $document_root$fastcgi_script_name; fastcgi_param PATH_INFO $fastcgi_script_name; include /etc/nginx/conf/fastcgi_params; } }#sever2 }#http I could just detect the mobile browsers with php or javascript but i need to make the detection at the server level so that i can use the 'm' in m.mywebsite.com as a flag in my controllers (codeigniter) to serve up the right view. I hope someone can help me! Thank you!

    Read the article

  • MultiPath configuration on RHEL5 and Clariion CX-300

    - by Kamil Z
    I have problem with discovering my FC-connected CX-300 storage. Frankly speaking I'm complete novice in FibreChannel, so step by step explanation would be appreciated. My configuration consist of two IBM HS20 blades with RHEL5.4 on board and 2x Qlogic ISP2422-based 4Gb Fibre Channel HBAs on each blade. As a FC switch there are two Brocades built in BladeCenter Chassis, and finally there is EMC Clariion CX-300. CX300, and Brocade switches should be configured properly, because they were working fine with previous configuration, which main defference was RHEL3 instead RHEL5.4 Below there is my output from several usefull commands: #lspci | grep Fibre 06:01.0 FibreChannle: Qlogic Corp. ISP2422-based 4Gb Fibre Channel to PCI-X HBA (rev 02) 06:01.1 FibreChannle: Qlogic Corp. ISP2422-based 4Gb Fibre Channel to PCI-X HBA (rev 02) #lsmod | grep qla qla2xxx 1084741 0 scsi_transport_fc 37577 1 qla2xxx scsi_mod 141717 10 scsi_dh,qla2xxx,sg,scsi_transport_fc,usb_storage,libata,mptspi,mptscsih,scsi_transport_spi,sd_mod #cat /proc/scsi/scsi Attached Devices: Host: scsi0 Channel: 00 Id: 00 Lun: 00 Vendor: LSILOGIC Model: 1030 IM IM Rev: 1000 Type: Direct-Access ANSI SCSI revision: 02 Host: scsi0 Channel: 01 Id: 00 Lun: 00 Vendor: IBM-ESXS Model: ST936701LC FN Rev: B418 Type: Direct-Access ANSI SCSI revision: 04 Host: scsi0 Channel: 01 Id: 00 Lun: 00 Vendor: IBM-ESXS Model: ST936701LC FN Rev: B418 Type: Direct-Access ANSI SCSI revision: 04 I'd followed instructions from this site (editing /etc/multipath.conf), but i failed after multipath -ll - the output was empty. Do you have any suggestions about discovering FC Connected LUNs in such configuration?

    Read the article

  • Developer's PC - worth getting more than 8GB RAM?

    - by Borek
    I'm building a developer PC and am wondering whether to get 8GB or 12GB. It's a Core-i7 860 system, i.e., 1156 motherboards with 4 slots for RAM sticks, dual channel, usually up 16GB (as opposed to 1366 sockets where 6 banks / triple-channel are used). 8GB would be cheaper to get especially because price per GB is lower with 4x2GB compared to 2x4GB. Also the availability is worse for 4GB DIMMs here where I live; those are the main practical advantages of 8GB. (Edit: I should have stressed the price difference more - in the eshop I'm buying from, the difference between 12GB and 8GB is so big that I could almost buy a whole new netbook for it.) However, I understand that more RAM can never do harm which is the point of this question - how much of a difference will 12GB make as opposed to 8GB? Honestly, I've always been on 3.2GB systems (4GB but 32bit system) and never felt much pain from having too little memory - of course there could be more but for instance compiler's performance was usually held back by slow I/O or not utilizing multiple cores on my CPU. Still, I'm not questioning that 8GB will be useful, however, I'm not sure about the additional 4GB difference between 8 and 12 gig. Anyone has experience with 8GB / 12GB systems? The software I usually run all the time: Visual Studio or Eclipse (both should be fine with ~2GB RAM, after that I feel their performance is I/O bound) Firefox (it can never have enough RAM can it? :) Office (~500MB RAM should be enough) ... and then some smaller apps like Skype, other browsers, some background services etc.

    Read the article

  • MacBook Pro battery capacity 65K mAh

    - by Alexander Gladysh
    I have a 15" MacBook Pro 3.1 (that is Late 2007 model AFAIR). I've bought it new a couple of years ago. Recently its on-battery power lifespan became very short (30 to 10 minutes). When my notebook turns itself off due to "low battery" and I press the small button on the battery itself, all LED lights are alight, indicating full charge. When I plug in the power adapter, my Mac displays that "battery is fully charged, finishing charging process" (I have a Russian OS X 10.5.7, so that is a rough translation), but the LEDs on battery itself display (seemingly accurate) status that there are one or two "LEDs still not charged". My battery have as few as 37 recharge cycles (yes, I've neglected calibration over the time I've used it). Battery info programs like iBatt2 report battery capacity of 65 337 mAh (with by-design capacity of 5600 mAh). I get it that something went wrong with battery electronics. I've tried resetting my Mac's PRAM and SMC, it did not changed anything. Now I'm trying to recalibrate the battery, but looks like it does not help as well. Will try to recalibrate it several times in a row. I'd buy a new battery if I knew if it is battery fault, not a notebook's. Any suggestions? Update: After recalibration, my battery status now displays battery capacity of 1500 mAh. But with every recalibration (or simply when I use notebook without power adapter plugged in) this number changes in the range from 200 mAh to 1700 mAh. LEDs on battery now are synchronous with what nodebook thinks on the charge level. Also I've noticed that cycle count changes rather slowly. It is now 39, it was 37 when I've started recalibration, and I went through the process at least ten times... So, the main question is: does it look like that replacing the battery would help me (or does it look like this is notebook's problem)? I guess I should try replacing the battery.

    Read the article

  • Can't connect to LAN when connected to D-Link DIR-615

    - by Senseful
    I'm have a D-Link DIR-615 Wireless N 300 Router. I didn't use the CD it comes with to set up the network. Instead I configured it manually through the router's settings that are accessed via a web browser. The main changes I made are: Secured the router so that a password is required before clients can use the wireless internet. Broadcasting 802.11N only (not B or G). I can connect to the router just fine and I'm able to access the internet. The only problem is that I don't see any of the other computers in my LAN. When I try connecting to another Wi-Fi router that I have (which is connected to the same network), I can see all of the computer's on my LAN just fine. Therefore, I'm guessing that the reason I can't connect to the LAN is not a problem with my computer and is a problem with the router instead. I'm on a MacBook Air running Mac OS X 10.6.6. I tried contacting D-Link technical support, but they only try to help you if you have problems connecting to the internet. They aren't really concerned with problems that have to do with the accessing PC's on the same network.

    Read the article

  • Modem doesn't seem to pass internet connection to router

    - by Vian Esterhuizen
    I was supplied a Cisco DPC3825 modem by my ISP and use a Cisco E4200 as my main router. Today the Internet just stopped working, just out of the blue, I can't think of anything that would have triggered it. It's been working pretty good for the past month except for a few random blips here and there. After some trouble shooting I realized that a direct wired connection to the modem would get me Internet access but if I was wired to the router as I was before I would have no connection. Assuming it was router I connected a TP-Link WR841N but it had the exact same problem. Also, connecting to the router via Wi-Fi from multiple devices will connect me to the router but I still can't get access to the Internet. From these test, it seems that the modem just won't send Internet through to the router but is clearly connecting and able to directly connect to my PC. What I've Tried A full reset and factory reset on the E4200 A full reset on the modem (but I believe my ISP has remote access to the modem because the passwords and so on are always set back). My ISP has remotely reconfigured the modem What I Should Try What else can I try? What should I do to try to narrow down the issue? Can you figure out what the problem might be based on this information?

    Read the article

  • Advice on migrating from a Samba PDC

    - by pgb
    When we started our software development company, we decided to use Samba as a PDC for the few Windows workstations we had. We use Samba with OpenLDAP, and it has been a good replacement for AD for almost 6 years now (using Windows XP workstations). Now I'm facing a few problems with our setup: The Linux server where the PDC runs is very outdated (and is a Gentoo install, don't ask why!) We started using Windows 7 on some of the workstations, and these can't join the Samba domain (there's a workaround, I know) Our company has grown a bit, and we have now about 20 workstations (and plan to have more in the near future). I have to reinstall our PDC, and was thinking on updating to another Linux distro and the latest Samba 3.4. However, I started having second thoughts, and now I think going to a Windows Server for the PDC is the way to go. The main drivers to opt for a Windows Server would be its easy administration and the ability to use Windows 7 out of the box, without any registry hacks. My question(s) then is(are): How should I do this migration? Can I keep the same domain name? What will happen to the users? Will they be recreated and won't be identified by the workstations as being the same user, even if the actual username is the same? What steps would you recommend me to migrate from Samba to Windows Server? Bonus question: If you think staying in Samba is the way to go with my current setup, I'm also interested on your thoughts.

    Read the article

< Previous Page | 624 625 626 627 628 629 630 631 632 633 634 635  | Next Page >